HomeMy WebLinkAbout04-04 Impact AnalysisIMPACT STATEMENT
EAN PROPERTY
REZONING
Red Bud District
Frederick County, Virginia
TM 55 -((A)) -208
5.0 Acres
Current Owners:
Contact Person:
November 4, 2003
Helen R. Bean
561 Bean's Pond Lane
Winchester, VA 22602
Evan Wyatt, AICP
Greenway Engineering
151 Windy Hill Lane
Winchester, VA 22602
540- 662 -4185
Greenway Engineering
BEAN PROPERTY REZONING
INTRODUCTION
This report has been prepared for the purpose of assessing the impact on Fredrick County
by the proffered rezoning of a five -acre (5.0) parcel owned by the Helen R. Bean,
represented by the Trustees of the Helen R. Bean Trust. The subject parcel is located on
Bean's Pond Lane, approximately 1/2 mile north of Senseny Road (Route 657). The 5.0-
acre parcel is encompassed by the Lynnhaven development on the northern, western and
southern boundaries and by the future expansion of Channing Drive on the eastern
boundary. The current zoning is RA, Rural Areas District. The Helen R. Bean Trust
proposes to rezone the 5.0 -acre parcel to RP, Residential Performance District. Please
see the attached Bean Property Location Map.
Basic information
Location:
Magisterial District:
Property ID Number:
Current Zoning:
Current Use:
Proposed Use:
Proposed Zoning:
Total rezoning area:
COMPREHENSIVE PLAN
The proposed site is being developed in conformance with the Comprehensive Policy
Plan. The Comprehensive Policy Plan states that suburban residential development will
occur within the Urban Development Area (UDA). Senseny Road is designated as a
major collector road and has been a developing suburban residential corridor since the
inception of the UDA.
1. Urban Development Area
Expansion of the Urban Development Area (UDA) beyond its existing boundary is not
required by this application.
File #2185R /EAW
November 4, 2003 Bean Property Rezoning
Bean's Pond Lane, approximately mile north of
Senseny Road (Route 657)
Red Bud
55 -((A)) -208
RA District
Residential
Single Family Detached Urban Residential Lots
RP District
5.0 acres
2
Green way Engineering November 4, 2003 Bean Property Rezoning
2. Sewer and Water Service Area
Expansion of the Sewer and Water Service Area (SWSA) beyond its existing boundary is
not required by this application.
A. SUITABILITY OF THE SITE
Access
The subject site, tax parcel 55 -((A)) -208 has access along Bean's Pond Lane. The
continuation of Channing Drive will eliminate Bean's Pond Lane as development in
Lynnhaven and Sovereign Village progresses. The 5.0 -acre parcel will have access
through the extension of a planned local subdivision street from the Lynnhaven
development. Channing Drive is a planned major collector road; therefore, direct access
to the 5.0 -acre site on Channing Drive is prohibited. The 5.0 -acre parcel will have
approximately 830 feet of frontage along Channing Drive.
Flood Plains
The subject site is located on the FEMA NFIP map #510063- 0120 -B. The site is located
as "Zone C area outside the 100 -year flood plain.
Wetlands
The National Wetlands Inventory Map indicates that there are no wetlands on the subject
site.
Soil Types
The following soil types contained in this tract have been obtained from the Soil Survey
of Fredrick County, published by the USDA Soil Conservation Service.
The subject site is located on map sheet number 37, and contains three soil types:
41C-Weikert Berks Channery Silt Loam 7 -15% covers 10% of this site
41D- Weikert-Berks Channery Silt Loam 15 -25% covers 80% of this site
41E- Weikert- Berkis Channery Silt Loam 25 -60% covers 10% of this site
The Weikert Berks Channery Silt Loam soils are not classified as prime farmland soils in
Table 5 on page 123 of this document.
File #2185R/EAW
3
Greenway EngineeriTg November 4, 2003
B. SURROUNDING PROPERTIES
Adjoining property zoning and present use:
North: Zoned RP District
South: Zoned RP District
East: Zoned PR District
West: Zoned RP District
C. TRANSPORTATION
D. SEWAGE CONVEYANCE AND WATER SUPPLY
File #2185R /EAW
4
Undeveloped (Future Lynnhaven Subdivision)
Undeveloped (Future Lynnhaven Subdivision)
Vacant (Future Sovereign Village Subdivision)
Vacant (Future Lynnhaven Subdivision)
Bean Property Rezoning
The subject site is proffered to contain a maximum of 12 single- family detached urban
residential lots that are a minimum of 12,000 square feet. The Institute of Transportation
Engineers (ITE) Trip Generation Manual, 6` Edition identifies an average daily traffic
rate of 9.57 vehicle trips for single- family detached housing. ITE projections suggest that
115 average vehicle trips will be generated by 12 single family dwelling units. A
residence currently exists on the 5.0 -acre parcel; therefore, the net increase in traffic
generation volume from the proffered rezoning is projected at 103 vehicle trips per day.
The 2002 Virginia Department of Transportation Daily Traffic Volumes identifies 5,200
average daily vehicle trips on this segment of Senseny Road. The proffered number of
residential units will increase the average daily traffic volume on Senseny Road by 1.98%
of the 2002 volume. The development of the Lynnhaven and Sovereign Village
Subdivisions will provide for the construction of Channing Drive, which will connect
Senseny Road to Valley Mill Road (Route 659). Additionally, these subdivisions will
provide for the development of Farmington Boulevard, which will connect to Greenwood
Road (Route 656) to the east. These major collector road networks will be sufficient to
accommodate the projected traffic generation from the 5.0 -acre parcel.
The subject site is proffered to contain 12 single- family detached urban residential lots
that will be served by public water and sewer. A projected water demand of 250 gpd is
reasonable for single family detached housing; therefore, the projected average daily
water demand for the 5.0 -acre rezoning is 3,000 gpd. The Frederick County Sanitation
Authority (FCSA) is currently providing between 3 -4 mgd of potable water to Frederick
County and can easily accommodate the water demands associated with 5.0 -acre parcel.
Greenway Engineering November 4, 2003 Bean Property Rezoning
The Greenwood Heights Sewage Pumping Station currently accommodate sewage flows
in the area of the 5.0 -acre parcel through a force main that transmits effluent to the
Opequon Water Reclamation Facility on Berryville Pike (U.S. Route 7). A regional
pump station is being designed for this area of the County that will provide force mains to
accommodate and redirect flows from the Greenwood Heights Sewage Pumping Station,
the Apple Ridge Sewage Pumping Station, the Burning Knolls Sewage Pumping Station
and the U.S. 50 East Sewage Pumping Station to the Opequon Water Reclamation
Facility. It is anticipated that the new regional pump station will be on -line within 18
months. A projected sewage conveyance of 200 gpd is reasonable for single- family
detached housing; therefore, the projected average daily sewage conveyance for the 5.0-
acre rezoning is 2,400 gpd. The Opequon Water Reclamation Facility has a hydraulic
capacity of 8.4 mgd; therefore, there is adequate capacity to accommodate the projected
average daily sewage conveyance produced by the subject site.
E. DRAINAGE
The 5.0 -acre site drains to the east towards the Opequon Creek. Future development will
direct storm water flows to culverts within Channing Drive to ensure continuity with the
overall storm water management plan for the Channing Drive Master Development Plan.
F. SOLID WASTE DISPOSAL
The impact on solid waste disposal facilities can be projected from an average annual
household impact to landfill volume of 5.4 cubic yards per household. Therefore, the
projected average annual impact to the Municipal Solid Waste portion of the Regional
Landfill is 64.8 cubic yards for the 5.0 -acre site. The Municipal Solid Waste Landfill has
a current capacity of 7,800,000 cubic yards, which can easily accommodate the additional
solid waste by this project.
G. HISTORICAL SITES AND STRUCTURES
The Frederick County Rural Landmarks Survey does not identify potentially significant
structures or sites on or within the proximity of the 5.0 -acre parcel. The Comprehensive
Policy Plan does not identify this area as a potential historic district, nor does it identify
core battlefield areas on or within the proximity of the 5.0 -acre parcel.
File #21852 /FAW
5
Greenway EngineenTig November 4, 2003
H. OTHER IMPACTS
A monetary proffer of $9,690.00 has been provided for each residential lot that will be
located completely on the 5.0 -acre parcel, or if the majority of the residential lot is
located on the 5.0 -acre parcel. This monetary proffer has been provided to mitigate the
impacts to public service capital facilities costs as demonstrated by the Frederick County
Capital Facilities Fiscal Impact Model. All impacts associated with the rezoning of the
5.0 -acre site have been addressed in this document.
File #2185RIEAW
Bean Property Rezoning
IC nipirwIts 3 ant*, a ��Ori
/10 .111
2
Bean Property Rezoning Location Map ByGreen ayEngineeriing
Founded in 1971
Remarks:
1
GREENWAY ENGINEERING
151 Windy Hill Lane
Winchester, Virginia 22602
TRANSMITTAL
Project Name: Bean Property Rezoning
File No.: 2185R
Date: November 6, 2003
To: FC Planning
Attn: Jeremy Camp
Copied:
From: Evan Wyatt
GREENWAY ENGINEERING
Phone: 540 -662 -4185
Fax: 540- 722 -9528
F Urgent fl For Your Review r As You Requested f-1 Please Comment
Message:
Hi Jeremy,
Please find attached a rezoning application for the 5.0 -acre Bean parcel located off of Senseny
Road. Please review this information and provide me with your comments. Thank you for your
assistance with this project.
Have a good day,
Evan
NOV 0 6 2003
FREIERICK COUNTY
PLANN1N38, DEVELOPMENT
SQAd \\\J 1
3y./A
Engineers Surveyors
Telephone 540- 662 -4185 FAX 540 -722 -9528
greenway @visuallink.com
9.`"