HomeMy WebLinkAbout26-10 Application1
2.
3.
E
OCT 2 9 2010
SITE PLAN APPLICATIO
T
Project Title: A(n -m W ly'eUgj- Mm ChKl�r '�wCj-
Location of Property a D D-`n OVA) ()Y W I II GhPC r
(street address)
Property Owner:
Address: Lt,;,
aao Lys bL
)�W) 13r W rrc,tta4 - VA-
Telephone:
Applicant /Agent
Address
Telephone:
5. Designer:
Address:
Telephone:
Contact:
ayo- 4o) -tf4.(Y- j
C
•
6a. Is this a standard or'minor' site plan?
6b. Is this an original or revised site plan?
7a. Total acreage of parcel to be developed:
7b. Total acreage of parcel:
8. Property Information:
a) Property Identification Number:
b) Current Zoning:
C) Present Use:
d) Proposed Use:
e) Adjoining Property Use(s)
f) Adjoining Property Identification Number(s)
g) Magisterial District(s)
Standard
Original _
Minor
Revised
Al Clmlylun ya'ryon -AgC1 h
- �YI�IA �fYiCt,�
S'iA pQ.j(iQ -��
I have read the material included in this package and understand what is required by the Frederick County
Planning Department. I also understand that all required material will.be complete prior to the submission
of my site plan.
�n
Si <Inaturej , /XLA �-�j��j (a?1lq
Date: bo
0
NETWORK BUILDING
& CONSULTING, LLC
Over 25 years experience
On behalf of Verizon Wireless, this request for Site Plan approval is submitted to
Frederick County, Virginia for a proposed Verizon Wireless telecommunication facility
on an existing 146 feet monopole located at 220 Imboden Drive, Winchester, VA.
The proposed facility will consist adding of installing 12 antennas at height of 136 feet.
Near the base of the monopole within the existing fenced area, there will be one
12'x20'xl0' equipment shelter and on backup generator on a 10'x4' concrete pad.
Currently, Verizon Wireless has a building permit application into the County for the
proposed facility and was informed by Mr. Mark Cheran, that our request also required a
site plan approval.
The proposed facility will be unmanned and will only require periodic routine
maintenance visits by one technician to the site, no more than 4 -6 times per year and as
required for emergencies. There will no offensive odor emitted by the equipment or
antennas. There will no harmful emissions, nor electrical interference from the antennas.
There will be no adverse impact to the use and development of the surrounding properties
The size, scale and density of this proposal will not adversely impact the character of the
area and as proposed; Verizon has designed this site so that the visual impacts of the have
been minimized. Verizon Wireless will operate this facility in full compliance with
federal, state and county ordinances. Verizon Wireless therefore respectfully request
approval of this site plan application.
Copies of the site plan have been sent to following agencies:
Fire Marshall
Frederick County Engineering _Department
Winchester Regional Airport
Frederick County Inspections Department
7380 COCA COLA DR., SUITE 106, HANOVER, MD 21 076
P 41 0.71 2.7092 • F 41 0.71 2.4056 • WWW.NETWORKBUILDINC3.COM
O
`� NETWORK BUILDING
\ & CONSULTING, LLC
Over 25 years experience
The following items have been included with this request
• 1 signed application form
m 2 sets of site plans with elevation view and antennas specifications.
• Filing fee
Please contact Stephanie Petway, Agent for Applicant (Verizon Wireless) if there any
questions, concerns or additional information is needed concerning this site plan
application and request.
Stephanie M. Petway
Network Building & Consulting
7380 Coca Cola Drive
Suite 106
Hanover, MD 21076
240 -401 -0907 (mobile)
spetway @nbcllc.com
73RD COCA COLA DR., SUITE 106, HANOVER, MD 21076
P 410.71 2.7092 • F 410.71 2.4056 • www.NETWORKBUILDINr..com
0 r
Request For Site Plan Comments
Department of Planning and Development
Mail to:
Department of Planning and Development
Attn: County Planner
107 North Kent Street
Winchester, VA 22601
(540) 665 -5651
Hand deliver to:
107 N. Kent Street
North Building, 2nd Floor
Winchester:,. VA
(540) 665 -5651
Please fill out the information as accurately as possible in;order to assist the agency with their
review. Please attach two (2) copies of the site plan with this sheet.
Applicant's Name:
Address:
Ve(lib)
Phone Number: o qo- 40)-MO--7
of development and lor of the request'
('r"M4i('mhtin It )ab9[r Frt^.I1J _ iA
D
Location of property: QJ'O X1'1'1 bAt_n , t-JD--
Planning and Development's Comments:
15
�11
SITE PLAN APPLICATION CHECKLIST
Tlie checklist shown below specifies the information which is required to be submitted as part of the site plan
application. The Department of Planning & Development will review the application to ensure that it is
complete; prior to accepting it. If any portion of the application is not complete, it will be returned to the
applicant(s).
_ (1) One (1) set of approved comment sheets are required from each relevant review
agency prior to final approval of a site plan. It is recommended that applicants
contact the Department of Planning & Development to determine which review
agencies are relevant to their site plan application_ A list of potentially relevant
review agencies is shown below:
Frederick County Department. of Planning & D_ evelopment
Frederick County Sanitation.Authority
Frederick.County Building Inspections Department
Frederick' County Department of Public Works
Frederick County Fire Marshal
Frederick County Health Department
Frederick County Department 'of Parks & Recreation
Virginia-Department of Transportation (VDOT)
City of Winchester
Town of Stephens City
Town ofMiddletown
Frederick County / Winchester Airport Authority
GIs
(2) One (1) copy of the Site Plan application;fonn.
_ (3) Payment of tU'site plan review fee.
(4) One (i) reproducible copy of the Site Plan (if required).
o •
SITE PLAN CHECKLIST
The Site Plan Checklist, shown below, lists the information which is required to be on each site plan. Site plans which
are incomplete or missing information, will be returned to the applicant (s) £or revision.
Project Information Section
_
(1)
A title thatincludes the naute of the proposed or existing business and a subtitle which
describes the proposed development.
(2)
The name, address, and phone number of the land owner, developer, and designer.
(3)
The FrederickCount yPropertyIdentifcationNumber (PIN)ofalllotsincludedonthesite
plan.
(J�
(4)
The number and type of dwelling units included on the site plan for residential uses.
_ I?—
(5)
The total land area and total developed land area of all lots included on the site plan.
_
(6)
A detailed description of the proposed use or uses of the development, as well as a
description of the existing use or uses.
j r -
_ V
(7)
A reference to any other site plan of masterdevelopment plan approved by the county for
the site.
(8)
The date the site plan was prepared and a list of all revisions made, including the date and
a description of why the site plan was revised.
(9)
A table of contents including all pages of the site plan.
(10) A list of all proposed utility providers, with their address, name and phone number.
(11) An insetmapshowingthc location ofthe site, alongwith the location ofsn •eets,roadsand
land uses within five hundred (500) feet of the property.
(12) A statement listing alllequirements and conditions placed on the land included in the site
plan resulting:from approval of conditional zoning or a conditional use permit.
(13) A description of setbacks or conditions placed on the site as a result of an approved
variance.
(14) The name of the Magisterial District.the property is located within.
• •
Calculations Section
(15) Calculations showing the Floor Area Ration (FAR) of the site, including the maximum
allowed PAR, total ground floor area, total floor area, and total lot area.
Site Plat & Details' Section
I/ (21) The location of all adjoining lots with the owner's name, specific use, zoning, and zoning
boundaries shown.
(22) The location of all existing or planned right -of- -ways and easements that adjoin the
property, with street narues, widths, and speed limits shown.
V
(23) Allnearby entrances that are within two hundred (200) feet of anv existing or proposed
entrances to the site.
(24) All existing and proposed driveways, parkingand loading spaces, parking lots and a
description of surfacing material and construction details to be used. The size and angle
of parking spaces, aisles, maneuvering, areas, and loading spaces shall be shown.
(25)
(26)
(27)
(28)
(29)
_IZ— (30)
(3 l )
A North arrow.
A graphic scale and statement of scale.
• legend describing all symbols and other features that need description.
• boundary survey of the entire parcel and all lots included with distances described at
least to the nearest hundredth of afoot.
The presentzoniing of all portions of the site, with the location of zoning boundaries.
The location of all existing and proposed structures, with the height, specific use, ground
flow area, and total floor area labeled.
The location of all existing and proposed outdoor uses, with the height, specific use, and
land area labeled.
t0
(16)
Calculationsshowingthe total number of required and proposed parking spaces, including
the total. nunnber of existing and proposed spaces.
_ Or
(17)
Calculations showing the total number of required handicap spaces, including the total
number of existing and proposed spaces,
r
r�
(18)
Calculations showing the total number of required loading spaces, including the total
number of existing and proposed spaces.
_
(19)
Calculations showing the total number of required perimeter and interior trees required,
including the number of provided trees.
(20)
Calculations showing the percentage of the property that will be landscaped and the
percentage of woodlands disturbed.
Site Plat & Details' Section
I/ (21) The location of all adjoining lots with the owner's name, specific use, zoning, and zoning
boundaries shown.
(22) The location of all existing or planned right -of- -ways and easements that adjoin the
property, with street narues, widths, and speed limits shown.
V
(23) Allnearby entrances that are within two hundred (200) feet of anv existing or proposed
entrances to the site.
(24) All existing and proposed driveways, parkingand loading spaces, parking lots and a
description of surfacing material and construction details to be used. The size and angle
of parking spaces, aisles, maneuvering, areas, and loading spaces shall be shown.
(25)
(26)
(27)
(28)
(29)
_IZ— (30)
(3 l )
A North arrow.
A graphic scale and statement of scale.
• legend describing all symbols and other features that need description.
• boundary survey of the entire parcel and all lots included with distances described at
least to the nearest hundredth of afoot.
The presentzoniing of all portions of the site, with the location of zoning boundaries.
The location of all existing and proposed structures, with the height, specific use, ground
flow area, and total floor area labeled.
The location of all existing and proposed outdoor uses, with the height, specific use, and
land area labeled.
t0
VA-
IV A
—W
IV y �
IU Yt-
_ lvy%
— IV 1R
(32) Existing topographic contour lines at intervals acceptable to the Zoning Administrator.
Proposed finished grades shall be shown by contour.
(33) The location of the front; side, and rear yard setback lines required by the applicable
zoning district.
(34) The location and boundaries of existing environmental features, including streams,
floodplains, takes and ponds, wetlands, natural stormwater retention areas, steep slopes,
and woodlands.
(35) The location of outdoor trash receptacles.
(36) The location of all outdoor lighting fixtures.
(37) The location,,diutensions, and height of all signs.
(38) The location of required buffers, landscaping buffers, and landscaped screens, including
examples, typical cross sections or diagrams of.screening to be used. The location and
dimensions of required fencing, berms, and similar features shall be specified.
(39) The location of recreational areas and common open space.
(40) The location of all proposed landscaping with a legend. The caliper, scientific name, and
common name of all deciduous trees. The height atplanting , scientific name, and commoll
name of all evergreen trees and shrubs.
(41) The height at planting, caliper, scientific name, and common name shall be provided for
all proposed trees. The height at planting, scientific name and common name shall be
provided for all shrubs.
(42)
(43)
(44)
(45)
(46)
(47)
(48)
I/ (49)
The location of sidewalks and walkways.
The location and width of proposed easements and dedications.
A stormwater management plan describing the location of all stormwater management
facilities with design calculations and details.
A soil erosion and sedimentation plan describing methods to be used.
The location and size of sewer and water mains and laterals serving the site.
Facilities necessary to meet the requirements of the Fire Code.
Asigned seal of the certified Virginia land surveyor, architect, or engineer who prepared
the plan.
A space labeled "Approved by the Frederick County Zoning Administrator" for the
signature of the Toning Adm inistrator, approval date, and a statement that reads "site plan
valid for five (5) yeas from approval date."