Loading...
HomeMy WebLinkAbout25-10 Comments from other Depts.0 0 Request For Site Plan Comments Frederick County Inspections Department Mail to: Frederick County Inspections Department Attn: Building Official 107 North Kent Street Winchester, VA 22601 (540) 665 -5650 Hand deliver to: 107 North Kent Street Fourth Floor Winchester, VA (540) 665 -5650 Please fill out the information as accurately as possible in order to assist the agency with their review. Please attach one (1) copy of the site plan with this sheet. Applicant's Name: Greenway Engineering Address: 151 Windy Hill Line, Winchester, Virginia 22602 Phone Number: (540) 662 -4185 Name of development and /or'description of the request: Navy Federal Credit Union, Westview Business Centre -Lo[ 10 -Shop Addition Location of property: 141 Security Drive Inspections Department's Comments: //✓Y/ii s r111 / rya 4 u hrfrC r,l7' A C C fYVs 15 V 1 j ,-I JAN 1 3 2011 ;', 0 0 Building shall comply with The Virginia Uniform Statewide Building Code and Section 303 (13- Business) of the International Building Code /2006. Other codes that apply are [CC/ ANSI Al 17.1 -2003 Accessible and Usable Buildings and Facilities. Proposed addition shall maintain the existing building type of construction. Unlimited area buildings shall maintain a 60' open perimeter as required by code. Removing existing ADA ramp and reinstalling new one. Ramps with greater than 6" rise requires handrails on both sides. Guardrails/handrails shall comply with 2006 USBC /IBC Chapter 10. Fire exiting plan from the registered design professional will be required when submitting for building permit to verify ANSI and all required exits All structural plans submitted for permit application shall he sealed by a VA Design Professional. Please note the requirements in Chapter 17 of the IBC for special inspections for this type of structure.(soil, concrete, bolts, etc.) i s 1 �p 4 3 I i Randy Kepler • • From: Yealman, Kimberly M. (Kim.Yealman @VDOT Virginia.gov] Sent: Monday, November 15,2010 1:35 PM To Randy Kepler Cc: Smith, Matthew, P.E.; Funkhouser, Rhonda Subject: Navy Federal Credit Union, Weslview Bus Center Lot 10 Addition - Frederick County We have reviewed the above referenced plan dated October 22, 2010, and the proposed addition does not appear to have any impact on the VDOT nght-of -way. All of the work shown is outside of the right -of -way, and the plan is indicating that there will not be any increase in traffic, If the use should ever expand in the future, the entrance may need to be re- evaluated at that time At this time, there is no additional review needed by our office. Kim yeatman Virginia Department of Transportation Land Development - Permit Specialist Clarke, Frederick, Shenandoah 8 Warren Counties 540- 535 -1828 tax from : sn9 yes ennn Frederick County Fire Marshal • Reuuest For Site Plan Comments Frederick County Fire Marshal • Mail to: Hand deliver to: Frederick County Fire Marshal 107 North Kent Street Attn: Fire Marshal First Floor 107 North Kent Street Winchester, VA Winchester, VA 22601 (540) 665 -6350 (540)66.5 -6350 Please fill out the information as accurately as possible in order to assist the agency with their review. Please attach two (2) copies of the site plan with this sheet Applicant's Name: Greenway Engineering Address: 151 Windy Hill Lane, Winchester, Virginia 22602 Phone Number: (540) 662 -4185 Name of development and /or description of the request: Navy Federal Credit Union Westview Business Centre -Lot 10 -Shop Addition Location of property: 141 Security Drive Fire Marshal's Comments: 19 Fax from : ]B9 5i5 StnM • 1i -zo -eo i�.va rig. _ Conlrol number SPIU -0022 Project Name Navy Federal Shop Addition Address 151 Windy HJI Lane Type Application Site Plan Cunent Zoning LI Automatic Sprinkler System Yea Other recommendation Emergency Vehicle Acosta, Slamese Location Emergency Vehicle Access Comments Access Comments Addhlonal Comments Date received Data revlewed Date Revised 102612010 11!16.2010 Applicant Greemvay, Engineering City State Zip Applicant Phone Winchester VA 22602 540-6621185 Tax ID Number Fire Dmunct Rescue Daunt 6M.159S 21 21 Election District Recommendations Shawnee Automatic Fire Alarm System Residential Sprinkler System Yea No Rd:q 5. Yemen {;v Hydrant Location Adequate Roadway /Aisleway Width Plan Appmval Recommended Reviewed By Signature Y. S. Me* Showers Tide Fire Lane Required Yes Special Hazards No 0 0 FREDERICK COUNTY SANITATION AUTHORITY SITE PLAN REVIEW COMMENTS PO Box 1877, Winchester, VA 22604 540.868.1061 Voice 315 Tasker Road, Stephens City, VA 22655 540.868.1429 Fax Project Applicant 4,AAE & 61i4! `;142- Fi414— "•••" ' "_ - REVIEW STATUS �7 attention Rd&14 K K.FDL.F9 review number _ °t correct & resubmit appro ed as noted number of items to be corrected 1d approved You may submit just cover sheet and the revised sheets. DRAWINGS / send me by 42 �/�IJ/ 90& I. rint of sheets P 2. two CDs: each disc shall contain the following plan sheets a) One CD (containing all of the above noted sheets) shall be in PDF format. Each sheet shall be in its own file and be in landscape orientation. Each file shall be titled with the project name and appropriate sheet number. b) One CD (containing all of the above noted sheets) shall be in DWG format. Each sheet shall be in its own file and each sheet shall be titled with the project name and with the appropriate sheet number. Each sheet shall (1) be in landscape orientation, (2) be without border, (3) be in state plane coordinate system NAD 83, and (4) be compatible with AutoCAD 2006. c) Each of the two CDs shall be labeled with its format and project name, and placed in its own paper CD envelope. EASEMENTS ©1 N I need a copy of the recorded onsite water easement(s). Y 40 1 need a copy of the recorded offsite water and / or sewer easement(s). The easement document shall contain a plat and both shall be signed by the Authority. I need a copy of the recorded deed(s) of easement before service will be authorized. OTHER Y /(!9? This project also requires DEQ - Valley Region approval. 4411 Farly Road. P.O. Box 3000, Harrisonburg, VA 22801 (540 -574 -7814) Y /® This project also requires VDH — Lexington Office approval. 131 Walker St, Lexington, 11A 14450 (540- 463 -7136) Y /6) This project has a sewer pump station that FCSA will own. Title to the pump station site shall be granted to the Authority in fee simple absolute. Also, I require (1) a copy of DEQ's Certificate to Construct, (2) a copy of DEQ's Certificate to Operate, and (3) two copies of the station's O & M manual. These documents must be received before water meters will he released. Date: .27 4474'0 m G. Whitacre - Senior Engineer I JOV ' 10