HomeMy WebLinkAbout52-25 Agency ChecklistsSITE PLAN APPLICATION CHECKLIST
The checklist shown below specifies the information which is required to be submitted as part of
the site plan application. The Department of Planning & Development will review the application to
ensure that it is complete prior to accepting it. If any portion of the application is not complete, it
will be returned to the applicant(s).
❑✓ (1) Digital copy of all application materials. Electronic materials may be
provided on a flash drive, client FTP site, or email.
• Application form with signature
• Site Plan set
Iy I (2) Site Plan review fee (check) made out to the Treasurer of Frederick County.
✓� (3) Two (2) hard copies of the site plan for review with sign and seal. One (1)
full size plan set shall be provided to Planning and Development and one (1)
full size plan set should be provided to VDOT (2275 Northwestern Pike
Winchester, Virginia, 22603).
(4) Traffic Impact Analysis (if applicable, check with Planning and
Development).
10
SITE PLAN CONTENTS CHECKLIST
The Site Plan Checklist (�165-802.03), as outlined in the Zoning Ordinance and shown below, lists the
information which is required to be on each site plan. Site plans that are incomplete or missing information
will be returned to the applicant (s) for revision.
Project Information Section
❑✓ _ (1) A title that includes the name of the proposed or existing business and a subtitle
which describes the proposed development.
I y I (2) The name, address, and phone number of the land owner, developer, and
designer.
0
(3)
The Frederick County Property Identification Number (PIN) of all lots included on
the site plan.
a_
(4)
The number and type of dwelling units included on the site plan for residential uses.
❑�
(5)
The total land area and total developed land area of all lots included on the site
plan.
(6)
A detailed description of the proposed use or uses of the development, as well as
a description of the existing use or uses.
Q—
(7)
A reference to any other site plan, master development plan approved by the
county for the site.
I y I
(8)
The date the site plan was prepared and a list of all revisions made, including the
date and a description of why the site plan was revised.
0
(9)
A table of contents including all pages of the site plan.
0
(10)
A list of all proposed utility providers, with their address and phone number.
I y l
(11)
A location map showing the location of the site, along with the location of streets,
roads and land uses within five hundred (500) feet of the property.
(12)
A statement listing all requirements and conditions placed on the land included in
the site plan resulting from approval of conditional zoning or a conditional use
permit.
(13)
A description of setbacks or conditions placed on the site as a result of an
approved variance.
✓�
(14)
The name of the Magisterial District the property is located within.
Calculations Section
(15)
F _
(16)
(17)
(18)
F _
(19)
❑
(20)
Site Plan & Details Section
(21)
(22)
-_W]
(23)
Calculations showing the Floor Area Ration (FAR) of the site, including the
maximum allowed FAR, total ground floor area, total floor area, and total lot area.
Calculations showing the total number of required and proposed parking spaces,
including the total number of existing and proposed spaces.
Calculations showing the total number of required handicap spaces, including the
total number of existing and proposed spaces.
Calculations showing the total number of required loading spaces, including the
total number of existing and proposed spaces.
Calculations showing the total number of required perimeter and interior trees
required, including the number of provided trees.
Calculations showing the percentage of the property that will be landscaped and
the percentage of woodlands disturbed.
The location of all adjoining lots with the owner's name, specific use, zoning, and
zoning boundaries shown.
The location of all existing or planned right-of-ways and easements that are located
on or adjoin the property, with street names, widths, and speed limits shown.
All nearby entrances that are within two hundred (200) feet of any existing or
proposed entrances to the site.
(24) All existing and proposed driveways, parking and loading spaces, parking lots and
a description of surfacing material and construction details to be used. The size
and angle of parking spaces, aisles, maneuvering areas, and loading spaces shall
be shown.
(25) A North arrow.
- Fy-1- (26) A graphic scale and statement of scale.
✓-_ (27) A legend describing all symbols and other features that need description.
(28) A boundary survey of the entire parcel and all lots included with distances
described at least to the nearest hundredth of a foot.
- W _ (29) The present zoning of all portions of the site, with the location of zoning boundaries.
(30) The location of all existing and proposed structures, with the height, specific use,
12
ground floor area, and total floor area labeled.
❑✓
(31)
The location of all existing and proposed outdoor uses, with the height, specific
use, and land area labeled.
I y I
(32)
Existing topographic contour lines at intervals acceptable to the Zoning
Administrator. Proposed finished grades shall be shown by contour.
(33)
The location of the front, side, and rear yard setback lines required by the
applicable zoning district.
I y I
(34)
The location and boundaries of existing environmental features, including streams,
floodplains, lakes and ponds, wetlands, natural stormwater retention areas, steep
slopes, and woodlands.
(35)
The location of outdoor trash receptacles with details for all required screening
elements.
(36)
A Photometric Plan per §165-201.07.
(37)
The location, dimensions, and height of all signs.
(38)
The location of required buffers, landscaping buffers, and landscaped screens,
including examples, typical cross sections or diagrams of screening to be used.
The location and dimensions of required fencing, berms, and similar features shall
be specified.
0
(39)
The location of recreational areas and common open space.
I y I
(40)
The location of all proposed landscaping with a legend. The caliper, scientific
name, and common name of all deciduous trees. The height at planting, scientific
name, and common name of all evergreen trees and shrubs.
❑�
(41)
The height at planting, caliper, scientific name, and common name shall be
provided for all proposed trees. The height at planting, scientific name and
common name shall be provided for all shrubs.
(42)
The location of sidewalks and walkways, including all sidewalks or bicycle paths
required along any road right of way.
0
(43)
The location and width of proposed easements and dedications.
_ ✓�
(44)
A stormwater management plan describing the location of all stormwater
management facilities with design calculations and details.
(45)
A soil erosion and sedimentation plan describing methods to be used.
_1:1
(46)
The location and size of sewer and water mains and laterals serving the site.
13
(47) Facilities necessary to meet the requirements of the Fire Code.
(48) A signed seal of the certified Virginia land surveyor, architect, or engineer who
prepared the plan. The seal and signature of the engineer, surveyor or architect
shall be on each sheet of the site plan.
(49) A space labeled "Approved by the Frederick County Zoning Administrator" for the
signature of the Zoning Administrator, approval date, and a statement that reads
"site plan valid for five (5) years from approval date."
(50) All requirements specified elsewhere in the County Code, including but not limited
to the Subdivision Ordinance.
14
Project Name: Carmeuse Eastern Berm Project
Acreage (Disturbed Area Acreage): 16.66 Ares
PIN(s): 34-A-11
Address (or general location):
508 Quarry Lane, Clearbrook, Virginia 22624
Existing Zoning: EM
Proposed Use: Berm
Staff Name (Email Address):
Agency Name Completing Comments (select one):
Frederick Water
Virginia Department of Transportation
Winchester Regional Airport
Virginia Department of Health
Historic Resources Advisory Board
Frederick County (FC) Public Schools
FC Public Works
FC Inspections
FC Fire Marshal
FC Parks & Recreation
FC County Attorney
Other (Specify):
Reviewer Name (Email Address):
Review Agency Comments:
Comments that may not fit in the box should be attached to the cover sheet on agency or department letterhead.
Resubmission to address comments requested? Y EL or N Q
15
Review Checklist
.f
Frederick County, Virginia
Department of Public Works t
Subdivision/Site Plan Name: Carmeuse Eastern Berm Project
Engineer/Surveyor Name: Dan Brze=ynski, PE
Engineer/Surveyor Phone: (540) 771-2090
Tax Map (PIN): 34-A-11,
�y
Note: Provide sheet number(s) for each item or indicate if not applicable.
Requirements
Sheet
N/A
FC Check
Provide a note pertaining to temporary and permanent stabilization of denuded
C
S000 1
areas.
Provide a note pertaining to stabilization requirements for soil stockpiles.
if
Provide a note stating that vegetative stabilization shall be uniform, mature
,f
enough to survive and adequate to inhibit erosion.
Provide sediment trapping facilities as the first phase of land disturbing activity.
N/A
Provide a note requiring that dams, dikes and diversions be stabilized
it
immediately after construction.
Sediment traps and basins shall be installed if necessary and in the correct
N/A
location. Basins shall maintain structural integrity during 100-year 24 hour storm
event. (§79-3.A.1 Frederick County Code).
Cut and fill slopes shall be adequately stabilized. Fill slopes steeper than 3:1 will
,f
require a slope stability analysis and maintenance plan.
Provide adequate temporary or permanent channel, flume or slope drain for all
N/A
concentrated runoff down cut or fill slopes.
Provide adequate drainage or other protection whenever water seeps from a
if
slope face.
Provide adequate inlet protection for all operational storm sewer inlets.
CS2200-2201
Provide adequate channel protection for open conveyance and receiving
^ �
/ A
channel, provide adequate outlet protection for pipes and channels.
I V
Provide measures to minimize channel damage when conducting in -stream
N/A
construction.
Install temporary stream crossings of non -erodible material
N/A
All applicable federal, state and local regulations pertaining to working in or
crossing live watercourses shall be met - all applicable permits shall be
N/A
submitted with Land Disturbance application (§79-3.A.2 Frederick County
Code).
Provide a note stating that the bed and banks of a watercourse shall be
N/A
stabilized immediately after work in the watercourse is completed.
Provide appropriate notes regarding trenching practices in accordance with
^ �
/ A
4VAC50-30-40 subsection 16.
I V
Requirements
Sheet
N/A
FC Check
Provide a note requiring cleaning/removal of any sediment on public or private
CS00�1
roadways.
Provide a note requiring that all temporary controls be removed within 30-days
if
once no longer needed; trapped sediment must be removed and stabilized.
Provide adequate protection from erosion and sediment deposition for
CS2100-CS2201
downstream properties and waterways.
Demonstrate that concentrated stormwater runoff leaving the site discharges
directly into an adequate natural or manmade channel.
Demonstrate that two (2)-year runoff from the site does not overtop banks of
I ^ �V/ A
natural channels and does not cause erosion.
Demonstrate that discharge into the previously constructed man-made channels
N/A
are not overtopped by a ten (10)-year storm and the two (2)-year storm does not
cause erosion
Demonstrate that closed storm sewer systems contain the ten (10)-year storm.
^ �/
I A
V0)-year
Provide calculations and show ten (1HGL in the storm sewer profiles.
If offsite improvements are proposed, provide evidence of obtained easements,
N/A
etc.
Provide an analysis of the existing and ultimate characteristics of the watershed.
N/A
Provide responsible party and maintenance plan for the proposed detention
CS00� 1
facilities to include access, what is to be maintained?, how often?, who pays?
Provide energy dissipaters at the outfall of all detention facilities.
CS2200-2201
Provide calculations demonstrating that onsite ditches are adequate.
CS6100
All sheet flow leaving the site shall be at or below pre -developed rates or it must
^ �
/ A
be diverted to an adequate channel, pipe system or detention facility.
I V
All calculations and assumptions shall pertain to the entire development and its
N/A
ultimate build -out.
All measures utilized shall minimize the impact on waters of the State.
N/A
Project description - Describe the nature and purpose of the land disturbing
CS00� 1
activity and area (acres) to be disturbed.
Existing Site Conditions - Provide a description of the existing topography,
vegetation and drainage.
Adjacent Areas - Provide a description of neighboring areas such as streams,
lakes, residential areas, roads, etc., which might be affected by the land
disturbance.
Off -site areas - Describe any off -site land -disturbing activities that will occur.
"
Soils - Provide a brief description of the soils on the site giving such information
as soil name, mapping unit, erodibility, permeability, depth, texture and soil
�/�
structure.
Geology - Provide a brief description of the geology on the site related to
construction; i.e. methods of removal, use as engineered fills, Karst potential,
etc.
Requirements
Sheet
N/A
FC Check
Critical areas - Provide a description of areas on the site which have potentially
if
serious erosion problems.
E&S control measures - Provide a description of the methods which will be used
if
to control erosion and sedimentation on the site.
Permanent stabilization - Provide a brief description, including specifications, of
n
how the site will be stabilized after construction is completed.
Stormwater runoff narrative - Will the development of the site cause an increase
in peak runoff rates? Will it cause flooding? Describe the strategy to control
stormwater runoff.
Calculations - detailed calculations for the design of temporary sediment basins,
permanent stormwater detention basins, diversions, channels, etc. Include
N/A
calculations for pre- and post -development runoff
Provide a vicinity map.
CS0000
Provide a North arrow and scale on all plan sheets.
All Sheets
Delineate the proposed limits of clearing and grading.
CS2100-2101
Show and label existing contours.
CS2100-1001
Show and label final contours.
CS2200-2201
Show existing vegetation.
CS1001-1002
Show boundaries of different soil types.
CS0001
Show existing drainage patterns including the acreage of each drainage area.
CS2100-2201
Label areas with potentially serious erosion problems.
N/A
Show and label all proposed site improvements.
CS2200-2201
Label all storm pipe systems on grading plan sheets (pipe size, material,
CS2200-4002
structure numbers).
Show elevations for the proposed basement floor, first floor and garage slab for
N/A
all buildings and finished grade elevations at building corners.
Show location of all retaining walls with elevations for proposed top and bottom
N/A
of walls.
Conveyance system protection and flood protection analysis provided at every
CS2200-2201
discharge point of concentrated flow originating from site improvements.
Show location of all erosion and sediment control measures using VESCH
standard symbols.
Show all off -site land disturbing activities and erosion and sediment control
measures. Provide letter of permission or show temporary construction
easements as necessary.
Provide stage -storage, stage -discharge and routing data for all SWM/BMP
N/A
ponds.
Provide VRRM spreadsheet data.
N/A
Requirements
Sheet
N/A
FC Check
Drainage area map showing individual and cumulative drainage area
CS2100-2201
contributing to each point of concentration.
Provide a maintenance schedule including regular inspection and repair of
CS��� 1
erosion and sediment control measures.
Provide the Responsible Land Disturber signature block on the plans.
CS0000
Provide a seeding schedule in accordance with VESCH standard 3.31 and 3.32.
CS4501
Provide a 20-foot drainage easement for all concentrated flows within on- or off-
N/A
site residential lots.
Provide a minimum of 2% slope on grass channels. If less than 2%, provide an
N/A
alternative design.
Any area in which drainage collects from more than three (3) lots shall be
N/A
placed within a platted drainage easement.
All silt fence shall be wire reinforced.
CS2100-2201
Drop Inlets in areas accessible to the public will require an appropriately sized
N/A
grate opening. Please specify the grate type in the plans.
Ensure that the backwater condition for the post -developed 100-year storm
N/A
does not impact adjacent properties.
Show the location and extent of the overland relief flow paths provided for SWM
N/A
conditions and to clear buildings for the 100-year storm.
Provide the dewatering structure details for the proposed sediment basins. The
N/A
details shall include elevations, type of structures, pipe sizes, etc.
Engineer's Signature
11/21/2025
Date
FREDERICK COUNTY
DEVELOPMENT REVIEW FEES
Revised - 03/21/2023
COMPREHENSIVE PLAN AMENDMENT
$3,000 non-refundable
REZONING
$1,000 — Proffer amendments not requiring a public
hearing
$5,000 base + $100/acre — 2 acres or less
$10,000 base + $100/acre
More than 2, less than 150
$10,000 base + $100/acre first 150
+ $50/acre over 150 acres
ADMINISTRATIVE TOWERS PER 165-204.19
Up to five facilities/structures $100
Each additional facility $50
Small Cell Facilities $50
Co -location on an existing wireless structure $50
SITE PLAN $2,500 + $200 (5) + $100 (12) = $4,700
Non-residential: $2,500 base
$200/acre to 5 acres
$100/acre over 5 acres
Residential: $3,500 base
SUBDIVISION
$300/unit to 20 units
Non -Residential $1,000 base
$100/unit over 20 units
Design Plan $200/lot
Plat $100/lot
Minor Site Plan: $500 for a new site plan that does not
Residential (RP, R4, 115)
exceed 10,000 SF of disturbed area and/or that increases
Design Plan $2,500/base $100/lot
existing structure area by 20% or less.
Plat $200/lot to 50 lots
$100/lot over 50 lots
POSTPONEMENT of any Public Hearing or Public
Rural Areas (RA)
Meeting by Applicant after Advertisement, to include
Sketch (Design) $2,500 base $200/acre
Applicant requests to TABLE an agenda item
Plat $200/lot
$750/occurrence.
Rural Areas (RA)
THIRD & SUBSEQUENT PLAN REVIEWS
Minor — 3 lots or less $200/lot
(Including County Attorney review) for a single
Lot Consolidation $200/lot
development application $500/review.
Boundary Line Adj. $200/lot
BOND MANAGEMENT
VARIANCE $400
Establishment of bond $ 500
Reduction/Release $ 300
BZA APPEAL $250
Replacement $ 300
ZONING CERTIFICATION LETTER $250
TDR PROGRAM
TDR Application Review $300
ZONING DETERMINATION LETTER $100
(*Review includes TDR Letter of Intent)
TDR Certificate $200
SUBDIVISION ORDINANCE
Certificate Ownership Transfer $50
EXCEPTION $500
Receiving Property Approval $200
Review of Sending Property
Deed Covenant $100
MASTER DEVELOPMENT PLAN
Review of Deed of Transfer (Extinguishment Document)
$3,000 base + $100/acre for first 150
$100
+$50/acre over 150 acres
CHAPTER 161 FEES
CONDITIONAL USE PERMIT
Installation License $300
Cottage Occupation S75
Septic Haulers Permit $200
Telecommunication Tower greater
Residential Pump and Haul $50
than 50-FT in height $750
Commercial Pump and Haul $500
Other S750
SHORT-TERM LODGING (STL)
Permit $200
STL Permit Renewals $100
32