HomeMy WebLinkAboutSP 47-25 - Thurston Companies - Daycare Site Plan Frederick Water ApprovalENGINEERSCONSULTINGTHURSTON COMPANIES, INC.WINCHESTER DAY CARELOT 7, ORRICK COMMONSTAX MAP: TM55-A-201HCOUNTY OF FREDERICK, VIRGINIASITE PLAN NO.: 25-xxxAPPROVED BY FREDERICK COUNTY ZONING ADMINISTRATORLIST OF DRAWINGS:Scale: 1" = 40'FREDERICK COUNTY, VIRGINIAPROJECT OVERVIEWCOUNTY OF FREDERICKVICINITY MAP 1" = 300'GENERAL NOTES:THURSTON COMPANIES, INCWINCHESTER DAY CARELOT 7, ORRICK COMMONSTAX MAP: TM55-A-201HCOUNTY OF FREDERICK, VIRGINIARED BUD MAGISTERIAL DISTRICTSITE PLAN #25-xxxRESPONSIBLE LAND DISTURBERPAINTER-LEWIS, P.L.C.Greenwood Rd.Country Park Dr.Green Park Ct.Green Park Dr.Grocery Ave.Senseny Rd.Senseny Rd.SITE FREDERICK WATER REVIEW NUMBER ______________ APPROVED APPROVED AS NOTED CORRECT & RESUBMIT __________ ITEMS TO CORRECT REVIEWER DATE__________________________________ 117Earl Wiley4November 19, 2025
ABBREVIATIONS:GENERAL CONSTRUCTION NOTES:VIRGINIA DEPARTMENT OF TRANSPORTATION NOTES:AGENCY NOTES:PAINTER-LEWIS, P.L.C.
ENGINEERSCONSULTING PROJECT TRIP GENERATION:
7'-6 1/4"9'-6 1/2"PLACE FIRE HYDRANT APPROX. 10' FROM STUB TO SHORTEN LENGTH OF 6" LINE AND PROVIDEGREATER HORIZONTAL SEPARATION TO STORM OR PROVIDE JUSTIFICATIONSHIFT GV SYMBOL TO 2'-3' OFF TEEWATER METER SHALL NOT BE PLACED WITHIN SIDEWALK; EVALUATE SOLUTION(S) TO PLACEWATER METER IN GRASSLABEL WATER METER SIZESHOW SCHEMATICALLY AND LABEL THE EXSITING WATER AND SANITARY SEWER WITHIN PLANVIEWSHOW AND LABEL ALL RECORDED EASEMENTS WITHIN PLAN VIEWREPLACE 1 1/2" WITH 2" ADD; 2" CORPORATION STOP AND 2" CTSPOLYETHELENE TUBINGMANHOLE SHALL NOT BE PLACED WITHIN CURB AND GUTTERADD; CORE DRILL, BOOT AND RESHAPING OF BENCH BY CONTRACTOREXISTING MANHOLE SHALL BE ADJUSTED TO GRADE AND RETESTED, ALL WORK SHALL BE PER THE FREDERICKWATER INSPECTORS REQUIREMENTSEVAULATE PLANS FOR THE BELOW NOTES AND ADD NOTES TO SPECIFIC ITEMS ASAPPLICABLEADD; SUPPLEMENTAL FREDERICK WATER NOTES TO PLANS:1)VALVES, MANHOLES, ARV’S AND OTHER FREDERICK WATER SURFACE FEATURES SHALL NOTBE PLACED IN CURB AND GUTTER, NOR SLOPED PORTION OF HANDICAPPED RAMPS.CONTRACTOR SHALL COORDINATE LOCATIONS WITH THE FREDERICK WATER INSPECTOR2) IRRIGATION LINES AND DEVICES, LIGHT POLES, TRANSFORMERS, JUNCTION BOXES,PEDESTALS, OTHER OBSTACLES AND ALL DRY UTILITIES SHALL NOT BE PLACED ONFREDERICK WATER EASEMENTS. PERPENDICULAR IRRIGATION LINES AND DRY UTILITYCROSSINGS ARE PERMITTED WITH 18" MINIMUM VERTICAL SEPARATION3) RETAINING WALLS AND THEIR TIE BACKS SUCH AS GEO GRID OR OTHER SUPPORTS SHALLNOT BE PLACED IN FREDERICK WATER EASEMENTS4) CONTRACTOR SHALL TEST PIT AS REQUIRED AND ADJUST ALL EXISTING FREDERICK WATERFACILITIES TO GRADE PER THE FREDERICK WATER INSPECTORS REQUIREMENTS5) IF EXISTING FREDERICK WATER FACILITIES ARE REMOVED, THE REMOVED ITEMS ANDRELATED MATERIALS SHALL BE REPLACED WITH NEW MATERIALS. REMOVED MATERIALSSHALL BE FURNISHED TO THE FREDERICK WATER INSPECTOR4'-0"VERIFY THAT ALL AGENCY FIRE FLOW REQUIREMENTS ARE ACHIEVED PROVIDE A CALCULATION ESTIMATING THE AVAILABLE FIRE FLOW AT THE PROPOSED HYDRANT.HAND CALCULATIONS OR A SIMPLE HYDRAULIC MODEL WILL BE ACCEPTABLE, ALONG WITH THEEXISTING HYDRANT FLOW TEST RESULTS NEEDED TO EVALUATE THE EXISTING SYSTEM. SUBMIT UNDER SEPARATE EMAIL PRIOR TO RESUBMITTAL IF NECESSARY. ONCE ACCEPTED, INCLUDE WITHIN PLAN SET1234567891011121314
ENGINEERSCONSULTING
PAINTER-LEWIS, P.L.C.
ENGINEERSCONSULTING
PAINTER-LEWIS, P.L.C.
ENGINEERSCONSULTING PAINTER-LEWIS, P.L.C.
ENGINEERSCONSULTING
PAINTER-LEWIS, P.L.C.NOTE: STORM WATER QUALITY REQUIREMENTS- IN ACCORDANCE WITH THE SITE DATA AS DETERMINED ABOVE, A TOTALPHOSPHORUS (TP) LOAD REDUCTION OF 0.56 lb./yr. IS REQUIRED DUE TO THE FULLDEVELOPMENT OF THIS SITE.- NO STORM WATER QUALITY MEASURES ARE PROPOSED NOR SHALL BE INSTALLEDAS PART OF THIS DEVELOPMENT. THIS RESULTS IN A DEFICIENCY OF 0.56 lb./yr. OFTP LOAD REDUCTION.- TO MAKE UP THIS DIFFERENCE, THE DEVELOPER WILL OBTAIN 0.56 lb./yr. OFNUTRIENT CREDITS FROM A CERTIFIED SUPPLIER TO SATISFY THIS REQUIREMENT.
ENGINEERSCONSULTING
PAINTER-LEWIS, P.L.C.LANDSCAPING CALCULATIONS AND GENERAL NOTES:RELOCATE TREES AND OR SHRUBS OFF FREDERICKWATER EASEMENTINDICATE WHERE CHECKLIST ITEM #14 CAN BE FOUNDON PLANS INDICATING NO TREES OR SHRUBS SHALLBE PLACED ON FREDERICK WATER EASEMENTS ORPLACE ON PLANSCONFIRM EXTENT OF FCSA EASEMENT AND RELOCATETREE OFF EASEMENT IF APPLICABLE151617
ENGINEERSCONSULTING
PAINTER-LEWIS, P.L.C.CACAD
ENGINEERSCONSULTING
PAINTER-LEWIS, P.L.C.
ENGINEERSCONSULTING
PAINTER-LEWIS, P.L.C.
ENGINEERSCONSULTING
PAINTER-LEWIS, P.L.C.
ENGINEERSCONSULTING NOPARKINGPAINTER-LEWIS, P.L.C.