Loading...
HomeMy WebLinkAbout03-25 Senseny Village II Signed Plan1 N/A SENSENY VILLAGE SUBDIVISION PLAN RED BUD MAGISTERIAL DISTRICT FREDERICK COUNTY, VIRGINIA SDP# 03-25 Gas:Shenandoah Gas Co. P.O. Box 2400 Winchester, VA 22604 (540) 869-1111 Phone:Verizon P.O. Box 17398 Baltimore, MD 21297 (301) 954-6282 Water/Sewer:Frederick Water P.O. Box 1877 Winchester, VA. 22604 (540) 868-1061 Power:Shenandoah Valley Electric Coop 3463 Valley Pike Winchester, VA 22602 (540) 450-2051 UTILITY NOTICE REQUIRED Contractors shall notify all public utility operators who maintain underground utility lines in the area of proposed excavating or blasting at least two (2) working days, but not more than ten (10) working days, prior to commencement of excavation or demolition. Names and telephone numbers of the operators of underground utility lines appear below. These numbers shall also be used to serve in an emergency condition. CALL "MISS UTILITY" VIRGINIA UTILITY PROTECTION SERVICE (VUPS) AT 811 OR 1-800-552-7001, 48 HOURS PRIOR TO THE START OF WORK. EXCAVATORS MUST NOTIFY ALL PUBLIC UTILITY OPERATORS WHO MAINTAIN UNDERGROUND UTILITY LINES IN THE AREA OF PROPOSED EXCAVATING OR BLASTING AND HAVE THOSE FACILITIES LOCATED BY THE UTILITY COMPANIES PRIOR TO COMMENCING EXCAVATION. THE EXCAVATOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL COUNTY REQUIREMENTS, VIRGINIA CODE AND REGULATIONS. VICINITY MAP SCALE: 1" = 1000' OWNER U.S. HOME LLC 14280 PARK MEADOW DRIVE CHANTILLY, VA 20151 703-449-6546 DEVELOPER MILLROSE PROPERTIES VIGINIA, LLC 501 OFFICE CENTER DRIVE FORT WASHINGTON, PA 19034 ---- Rappahannock Electric Coop 137 Kelly Court Front Royal, VA 22630 1-800-552-3904 05/15/2025 ZJ, KAS ---- 51 3924L151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVis with the free consent and in accordance with the desires of the undersigned owners, properties and trustees if any. SUBDIVISION ADMINISTRATOR OWNERS CERTIFICATE APPROVALS DATE DATE The foregoing Subdivision of the land of U.S. HOME LLC DATE THESE PLANS ARE IN CONFORMANCE WITH FREDERICK COUNTY STANDARDS AND ORDINANCES. ANY DEVIATION OR CHANGE IN THESE PLANS SHALL BE APPROVED BY THE ZONING ADMINISTRATOR PRIOR TO CONSTRUCTION LIST OF SERVICES: CIVIL ENGINEERING I GIS I PLANNING I LAND SURVEYING I ENVIRONMENTAL PHASE II COVER SHEETLANOIS S EFORP NE ENIG REW MOCOMNTAEL OHF NAIGRI IV RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIPlan Revisions Rev No Date Comment 01 07/01/2025 Culvert Updates 02 07/31/2025 Addressed VDOT and Frederick Water Comments 03 12/19/2025 Frederick Water and Planning Comments 04 02/06/2026 VDOT Comments and Frederick Water Comments 05 03/02/2026 VDOT General Notes Comment 06 06/29/2026 FC Planning Comments Sheet List Table Sheet #Sheet Title Sheet Rev. #Rev. Date 1 Cover Sheet 06 06/29/2026 2 General Notes 06 06/29/2026 3 Boundary 03 12/19/2025 4 Right-Of-Way 03 12/19/2025 5 E&S Phase IA 02 07/31/2025 6 E&S Phase I 02 07/31/2025 7 E&S Phase I (2)02 07/31/2025 8 Sediment Basin Details 02 07/31/2025 9 E&S Phase II 02 07/31/2025 10 E&S Phase II (2)02 07/31/2025 11 E&S Narrative 02 07/31/2025 12 E&S Details 13 E&S Details (2)02 07/31/2025 14 Geometry Plan 03 12/19/2025 15 Geometry Plan (2)03 12/19/2025 16 Grading Plan 02 07/31/2025 17 Grading Plan (2)02 07/31/2025 17A GER Settlement Plates, Reinforced Slopes, & Pavement Details 04 02/06/2026 17B GER Settlement Plates, Reinforced Slopes, & Pavement Details (2)04 02/06/2026 18 Utility Plan 04 02/06/2026 19 Utility Plan (2)04 02/06/2026 20 Stormwater Management Plan 21 Water Quality BMP Map 22 Water Quality BMP Map (2) 23 VRRM Comps 24 Pond 3 (WP) Plan 25 Bioretention 1 Plan and Jellyfish Details 26 Pond 1 (WP PH I) Update 27 Road Profiles 04 02/06/2026 28 Road Profiles (2)04 02/06/2026 29 Road Profiles (3)04 02/06/2026 30 Culvert 03 12/19/2025 31 Culvert (2)01 07/01/2025 32 Storm Sewer Profiles 01 07/01/2025 33 Storm Sewer Profiles (2)01 07/01/2025 34 Storm Sewer Profiles (3)01 07/01/2025 35 Sanitary Sewer Profiles 02 07/31/2025 36 Sanitary Sewer Profiles (2)02 07/31/2025 37 Water Line Profiles 02 07/31/2025 38 Water Line Profiles (2)02 07/31/2025 39 Water Line Profiles (3)02 07/31/2025 40 Storm Sewer Computations 41 Frederick Water Details 02 07/31/2025 41A Water Model 04 02/06/2026 42 VDOT Details 02 07/31/2025 43 VDOT Details (2)04 02/06/2024 44 VDOT Details (3)02 07/31/2025 45 VDOT Details (4)02 07/31/2025 46 Details 06 06/29/2026 47 Life Safety Plan 02 07/31/2025 48 Landscape and Lighting Plan 06 06/29/2026 49 Landscape and Lighting Plan (2)06 06/29/2026 50 Landscape and Lighting Plan (3)06 06/29/2026 51 Proffers 29Jun2026 N/A 2 05/15/2025 =J KAS ---- 51 2L151 WLQG\ HLOO LDQHWLQFKHVWHU VLUJLQLD 22602THOHSKRQH (50) 662-185FD[ (50) 722-528ZZZ.JUHHQZD\HQJ.FRPFND1971ENGINEERINGSHEET OF DESIGNED BY FILE NO. SCALE DATEPROUDLY SERVING VIRGINIA WEST VIRGINIAOFFICES IN WINCHESTER VA ASHBURN VA MARTINSBURG WVLEGEND PROPOSED SAN. LAT. CLEANOUT PROPOSED CENTERLINE EXISTING SPOT ELEVATION STORM DRAIN STRUCTURE IDENTIFIER SANITARY MANHOLE IDENTIFIER PROPOSED SPOT ELEVATION EXISTING CURB AND GUTTER PROPOSED EDGE OF PAVEMENT EXISTING EDGE OF PAVEMENT PROPOSED STORM SEWER WITH INLET EXISTING STORM SEWER WITH INLET PROPOSED TELEPHONE LINE EXISTING TELEPHONE LINE TRANSITION TO REVERSE CURB PROPOSED CURB AND GUTTER PROPOSED ELECTRIC SERVICE EXISTING ELECTRIC SERVICE PROPOSED SANITARY SEWER WITH MANHOLE EXISTING SANITARY SEWER WITH MANHOLE PROPOSED GAS LINE EXISTING GAS LINE FENCELINE FLOW LINE PROPOSED WATERLINE W/ TEE PROPERTY LINE EXISTING TELEPHONE PEDESTAL EXISTING WATERLINE W/ TEE EXISTING UTILITY POLE/GUIDE WIRE SIGNS PROPOSED REDUCER EXISTING FIRE HYDRANT/VALVE/METER INDICATES THE NUMBER OF TYP. PARKING SPACES PARKING INDICATOR HANDICAP PARKING PROPOSED BUILDING ENTRANCE VEHICLES PER DAY COUNT PROPOSED FIRE HYDRANT/VALVE/METER LIGHT POLE EXISTING TREE LINE EXISTING EASEMENT PROPOSED EASEMENT EXISTING CENTERLINE EXISTING INDEX CONTOUR EXISTING INTERMEDIATE CONTOUR PROPOSED CONTOUR PROJECT INFORMATION PDUFHO IGHQWLILFDWLRQ NRTM 65-((A))-B TM 65-((A))-55 PURMHFW SLWH AUHD7.7 AFUHV / 18.5 AFUHV (PKDVH II RHPDLQLQJ PDUFHO) DLVWXUEHG AUHD12.12 AFUHV CXUUHQW =RQLQJRP CXUUHQW UVHVDFDQW (UQLPSURYHG) PURSRVHG UVHSLQJOH-FDPLO\ AWWDFKHG (TRZQKRXVHV) PUHYLRXVO\ ASSURYHG PODQVRH]RQLQJ ASSOLFDWLRQ (RE=) 1-06 MDVWHU DHYHORSPHQW PODQ (MDP) 0-21 SXEGLYLVLRQ DHVLJQ PODQ (SDP) 02-21 FEMA FORRG =RQHX SWUHDP IPSDFW PHUPLW IQIRUPDLWRQ VADE4 PHUPLW WP-25-0778 COE PHUPLW  2025-01071 TRZQKRXVH MD[LPXP BXLOGLQJ HHLJKW 0' TRZQKRXVH PURSRVHG BXLOGLQJ HHLJKW 8' TRZQKRXVH RHTXLUHG SHWEDFNV PURYLGHG SHWEDFNV FURP RRDG ROW25'FURP RRDG ROW25' FURP RII-VWUHHW FURP RII-VWUHHW SDUNLQJ ORW15'SDUNLQJ ORW15' SLGH10' SLGH10' RHDU 20' RHDU 20' PDUNLQJ SHWEDFNV PURYLGHG PDUNLQJ SHWEDFNV FURP SWUHHW RU RRDG ROW10' FURQW SWUHHW RU RRDG RRZ10' FURP PURSHUW\ LLQHV5' FURP PURSHUW\ LLQHV5' SLJQ SHWEDFNV PURYLGHG SLJQ SHWEDFNV FURQW10'FURQWN/A SLGH10'SLGHN/A RHDU10'RHDUN/A * SLJQ DHWDLOV/SWUXFWXUH PODQV VXEPLWWHG LQ WKH IXWXUH XQGHU VSHFLDO SHUPLW UHTXHVW PDUNLQJ SSDFHV RHTXLUHG2.5 SHU WRZQKRXVH XQLW 78 WRZQKRXVH XQLWV [ 2.5 15 SDUNLQJ VSDFHV TRWDO SSDFHV PURYLGHG18 SSDFHV OSHQ SSDFH CDOFXODWLRQV(PKDVH 1 2 FRPELQHG) RHTXLUHG - 0 22.1 AFUHV PURYLGHG - 8 28.15 AFUHV IPSHUYLRXV AUHD 17.10 AFUHV OXWGRRU LLJKWLQJOXWGRRU OLJKWLQJ VKDOO FRPSO\ ZLWK †165-07.0 †165-807.05.B. SLJQVAOO VLJQV VKDOO FRQIRUP WR †165-80 RI WKH FUHGHULFN CRXQW\ =RQLQJ OUGLQDQFH. A IUHHVWDQGLQJ PRQXPHQW VLJQ LV SHUPLWWHG VR ORQJ DV LW LV LQ DFFRUGDQFH ZLWK TDEOH VIII-20 XQGHU †165-80-0.B. A VHSDUDWH VLJQ SHUPLW LV UHTXLUHG. RHTXLUHG RHFUHDWLRQ UQLWV1 UHFUHDWLRQ XQLW SHU 0 WRZQKRXVHV (†165-806.02 - TDEOH VIII-15) PKDVH I PKDVH IIPKDVH I FRQWDLQHG 1 WRZQKRXVHV PKDVH II FRQWDLQV 78 WRZQKRXVHV. 11/0 .7 UHF. XQLWV UHTXLUHG RU HTXLYDOHQW YDOXH DW 5000 XQLW 188 10277.02 ZDV VSHQW IRU UHFUHDWLRQDO IDFLOLWLHV LQ PKDVH I. 605.8 WR EH VSHQW RQ UHFUHDWLRQDO IDFLOLWLHV IRU PKDVH II. TKH W\SH RI UHF. IDFLOLWLHV VKDOO EH DSSURYHG E\ FC PDUNV RHFUHDWLRQ. SHH VKHHW 6 IRU IDFLOLWLHV SURSRVHG ZLWK PKDVH II IRU PKDVH I IDFLOLWLHV SOHDVH VHH WKH DSSURYHG PKDVH I SODQ. FIRE MARSHAL'S NOTE GENERAL PLAN AND CONSTRUCTION NOTES VDOT GENERAL NOTES FLUH ODQH PDUNLQJV DQG VLJQDJH AQ\ NR PDUNLQJ VLJQV DQG \HOORZ SDLQWHG FXUE ORFDWLRQV ZLOO EH LQVWDOOHG E\ ILHOG LQVSHFWLRQ DW WKH GLUHFWLRQ RI WKH FLUH MDUVKDO'V OIILFH. FREDERICK WATER PROJECT INFORMATION WATER AND SANITARY SEWER USAGE WATER DEMAND 180 GPD SANITARY SEWER DISCHARGE 180 GPD CDOFXODWLRQ RI GHPDQG/GLVFKDUJH WATER DEMAND *RHVLGHQWLDO 25 JSG SHU FRQQHFWLRQ *CRPPHUFLDO 75 JSG SHU 1000 VI *IQGXVWULDO 25 JSG # 10 SHUVRQV SHU DFUH SEWER DISCHARGE SHZHU GLVFKDUJH HTXDOV ZDWHU GHPDQG GENERAL 1.GUHHQZD\ EQJLQHHULQJ IQF. (GE) KDV LVVXHG WKLV SODQ VHW EDVHG RQ SURMHFW FULWHULD GLFWDWHG E\ WKH FOLHQW DQG PXQLFLSDO FRGHV. TKLV SODQ VHW LV QRW FRQVLGHUHG FRPSOHWH RU DSSURSULDWH IRU FRQVWUXFWLRQ XQWLO ALL QHFHVVDU\ DJHQFLHV KDYH JLYHQ DSSURYDO AND WKLV SODQ VHW LV VLJQHG DQG VHDOHG E\ D OLFHQVHG SURIHVVLRQDO. AQ\ ZRUN SODQQLQJ VFKHGXOLQJ PDWHULDO SXUFKDVHV DQG/RU FRQVWUXFWLRQ SULRU WR DSSURYDOV DQG OLFHQVHG/SURIHVVLRQDO VHDOLQJ ZLOO EH SHUIRUPHG DW WKH ULVN RI WKH SHUVRQQHO DXWKRUL]LQJ ZRUN. GE VKDOO EH KHOG KDUPOHVV IURP DOO FRVWV WLPH GHOD\V DQG/RU PDWHULDO FKDQJHV LQFXUUHG RQ DQ\ ZRUN WKDW LV SUHIRUPHG SULRU WR WKLV SODQ VHW EHLQJ DSSURYHG DQG VHDOHG. 2.TKH DSSURYDO RI WKHVH SODQV LQ QR ZD\ UHOLHYHV WKH DHYHORSHU CRQWUDFWRU SXEFRQWUDFWRU RU DQ\ RI WKHLU DJHQWV RI DQ\ OHJDO UHVSRQVLELOLW\ ZKLFK PD\ EH UHTXLUHG E\ WKH FRGH RI VLUJLQLD RU DQ\ CRXQW\ HQDFWHG ORFDO RUGLQDQFH QRU GRHV LW JXDUDQWHH WKH LVVXDQFH RI DQ\ UHTXLUHG SHUPLWV E\ WKH CRXQW\ SWDWH VDOT RU DQ\ RWKHU JRYHUQLQJ AJHQF\. .AQ DSSURYHG VHW RI SODQV DV ZHOO DV DOO DSSOLFDEOH SHUPLWV DQG UHTXLUHG GRFXPHQWV PXVW EH DYDLODEOH DW WKH FRQVWUXFWLRQ VLWH DW DOO WLPHV GXULQJ FRQVWUXFWLRQ. A UHSUHVHQWDWLYH RI WKH DHYHORSHU PXVW EH DYDLODEOH DW DOO WLPHV. .GE DQG/RU WKH EQJLQHHU VKDOO QRW QRW EH UHVSRQVLEOH IRU RU KDYH FRQWURO RYHU RU FKDUJH RI FRQVWUXFWLRQ PHDQV PHWKRGV WHFKQLTXHV VHTXHQFHV RU SURFHGXUHV QRU IRU VDIHW\ SUHFDXWLRQV DQG SURJUDPV LQ FRQQHFWLRQ ZLWK DQ\ ZRUN VKRZQ RQ WKHVH SODQV. GE DQG/RU WKH EQJLQHHU LV QRW UHVSRQVLEOH IRU DQ\ CRQWUDFWRU'V VFKHGXOHV RU IDLOXUH WR FDUU\ RXW WKH ZRUN. GE DQG/RU WKH EQJLQHHU LV QRW UHVSRQVLEOH IRU DFWV RI RPLVVLRQV E\ WKH CRQWUDFWRU SXEFRQWUDFWRU RU WKHLU DJHQWV HPSOR\HHV RU DQ\ RWKHU SHUVRQ SHUIRUPLQJ SRUWLRQV RI WKH ZRUN. 5.MHWKRGV DQG PDWHULDOV XVHG LQ WKH FRQVWUXFWLRQ RI WKH LPSURYHPHQWV KHUHLQ VKDOO FRQIRUP WR FXUUHQW CRXQW\ CRQVWUXFWLRQ SWDQGDUGV DQG SSHFLILFDWLRQV DQG/RU FXUUHQW VDOT SWDQGDUGV DQG SSHFLILFDWLRQV. SKRXOG D FRQIOLFW EHWZHHQ GHVLJQ VSHFLILFDWLRQV DQG WKHVH SODQV RFFXU WKH PRVW VWULQJHQW UHTXLUHPHQW VKDOO DSSO\. 6.TKH DHYHORSHU DQG/RU CRQWUDFWRU VKDOO EH UHVSRQVLEOH IRU FRQVWUXFWLQJ WKH VLWH LQ DFFRUGDQFH ZLWK WKH DSSURYHG SODQV DQG FRQVWUXFWLRQ GRFXPHQWV DQG WKH VFRSH RI ZRUN VKDOO FRQIRUP ZLWK JUDGHV GHSWKV GLPHQVLRQV HFW. VKRZQ KHUHRQ. 7.AOO NQRZQ FHPHWHU\ DQG/RU JUDYHVLWH ORFDWLRQV KDYH EHHQ LGHQWLILHG RQ WKHVH SODQV. AQ\ FHPHWHU\ RU JUDYHVLWH VKRZQ RQ WKHVH SODQV VKDOO EH PDUNHG DQG SURWHFWHG LQ DFFRUGDQFH ZLWK VWDWH ODZ. TKH GHYHORSHU RU FRQWUDFWRU VKDOO EH UHVSRQVLEOH IRU PDUNLQJ LQVWDOOLQJ SURWHFWLQJ DQG PDLQWDLQLQJ SURWHFWLRQ RI DQ\ NQRZQ VLWHV GXULQJ FRQVWUXFWLRQ DQG LQ WKH HYHQW WKDW DQ\ XQNQRZQ JUDYHVLWHV LV GLVFRYHUHG GXULQJ FRQVWUXFWLRQ WKH OZQHU DQG EQJLQHHU PXVW EH QRWLILHG LPPHGLDWHO\ DQG DGHTXDWH SURWHFWLRQ IURP FRQVWUXFWLRQ VKDOO EH LQVWDOOHG LPPHGLDWHO\. PERMITS AND INSPECTIONS 1.TKH DHYHORSHU RU KLV DJHQW VKDOO EH UHVSRQVLEOH IRU REWDLQLQJ DOO UHTXLUHG SHUPLWV IURP WKH DSSURSULDWH SWDWH DQG/RU ORFDO DJHQFLHV DQG WR FRPSO\ ZLWK WKHLU UHTXLUHPHQWV DQG DOO DSSOLFDEOH NDWLRQDO SWDWH DQG LRFDO ODZV DQG VKDOO EH UHVSRQVLEOH IRU REWDLQLQJ DQ\ UHTXLUHG SHUPLWV IURP WKH VLUJLQLD DHSDUWPHQW RI EQYLURQPHQWDO 4XDOLW\ (DE4) RU WKH UQLWHG SWDWHV AUP\ CRUS RI EQJLQHHUV IRU DQ\ SODQ ZHWODQG GLVWXUEDQFH DV PD\ EH VKRZQ RQ WKHVH SODQV. TKH\ VKDOO DOVR EH UHVSRQVLEOH WKH LGHQWLILFDWLRQ DQG GHOLQHDWLRQ RI DQ\ ZHWODQGV WKDW PD\ EH SUHVHQW RQ WKH FRQVWUXFWLRQ VLWH. 2.PULRU WR WKH LQLWLDWLRQ RI DQ\ ODQG GLVWXUELQJ DFWLYLWLHV WKH RHVSRQVLEOH LDQG DLVWXUEHU DHYHORSHU RU WKH CRQWUDFWRU VKDOO REWDLQ D LDQG DLVWXUEDQFH PHUPLW IURP WKH FUHGHULFN CRXQW\ PXEOLF WRUNV DHSDUWPHQW DQG VKDOO EH UHVSRQVLEOH IRU ILOLQJ D VLUJLQLD SWRUPZDWHU MDQDJHPHQW PURJUDP (VSMP) UHJLVWUDWLRQ VWDWHPHQW IRU WKH FRQVWUXFWLRQ VLWH DV UHTXLUHG E\ ODZ . TKH\ VKDOO DOVR EH UHVSRQVLEOH IRU REWDLQLQJ DQG PDLQWDLQLQJ RQ VLWH D SWRUPZDWHU PROOXWLRQ PUHYHQWLRQ PODQ (SWPPP). TKH DSSURYDO RI WKHVH SODQV LQ QR ZD\ UHOLHYHV WKH GHYHORSHU RU KLV DJHQW RI WKH UHVSRQVLELOLWLHV FRQWDLQHG LQ WKH VLUJLQLD EURVLRQ DQG SHGLPHQW CRQWURO HDQGERRN. .USRQ FRPSOHWLRQ RI DOO FRQVWUXFWLRQ DFWLYLWLHV DQG SHUPDQHQW VLWH VWDELOL]DWLRQ WKH DHYHORSHU VKDOO VXEPLW WR FUHGHULFN CRXQW\ PXEOLF WRUNV DHSDUWPHQW D DE4 NRWLFH RI THUPLQDWLRQ IRUP D FRS\ RI WKH VLWHV FRQVWUXFWLRQ LQVSHFWLRQ ORJ ERRN DQ HQJLQHHU FHUWLILHG UHG-OLQHG DV-EXLOW RI WKH DSSURYHG SODQV ZLWK FRPSXWDWLRQV IRU DOO SHUPDQHQW VWRUPZDWHU PDQDJHPHQW IDFLOLWLHV ZDWHU TXDOLW\ DQG VWRUPZDWHU FRQYH\DQFH V\VWHPV D UHFRUGHG FRS\ RI WKH UHTXLUHG BMP MDLQWHQDQFH AJUHHPHQW (LI QHHGHG)  DQ\ VSMP PHUPLW PDLQWHQDQFH IHHV (LI UHTXLUHG) DQG D ZULWWHQ UHTXHVW WR FUHGHULFN CRXQW\ PODQQLQJ IRU ERQG UHOHDVH. TKH DHYHORSHU VKDOO DOVR VFKHGXOH D FLQDO RQ VLWH LQVSHFWLRQ ZLWK FUHGHULFN CRXQW\ PXEOLF WRUNV DHSDUWPHQW. .TKH CRQWUDFWRU OZQHU RU DHYHORSHU PXVW REWDLQ D VDOT LDQG UVH PHUPLW (EQWUDQFH) IURP WKH OIILFH RI WKH RHVLGHQW EQJLQHHU VLUJLQLD DHSDUWPHQW RI TUDQVSRUWDWLRQ (VDOT) DQG SURYLGH WR FUHGHULFN CRXQW\ SULRU WR DQ\ FRQVWUXFWLRQ DFWLYLWLHV ZLWKLQ H[LVWLQJ SWDWH ULJKW-RI-ZD\. 5.TKH CRQWUDFWRU OZQHU RU DHYHORSHU VKDOO EH UHVSRQVLEOH IRU VFKHGXOLQJ DOO UHTXLUHG SWDWH DQG ORFDO LQVSHFWLRQV DQG IRU WKH VHFXULQJ RI DQ\ WKLUG SDUW\ LQVSHFWLRQ/WHVWLQJ VHUYLFH WR LQVXUH FRQVWUXFWLRQ FRPSOLDQFH ZLWK WKHVH SODQV DQG VSHFLILFDWLRQV DQG VKDOO NHHS DQG PDLQWDLQ D VLWH LQVSHFWLRQ ORJ ERRN. IW LV GUHHQZD\ EQJLQHHULQJ'V UHFRPPHQGDWLRQ WKDW D WKLUG SDUW\ LQVSHFWLRQ/WHVWLQJ VHUYLFH EH HPSOR\HG WR HQVXUH WKDW SURMHFW LV FRPSOLDQW DQG WKDW PDWHULDOV LQVWDOOHG PHHW WKH GHWDLOV DQG VSHFLILFDWLRQV LQ WKHVH SODQV. 6.AQ\ UHWDLQLQJ ZDOO 2 IW. RU JUHDWHU LQ KHLJKW VKDOO GHVLJQHG E\ D SWUXFWXUDO EQJLQHHU UHTXLUH WKH LVVXDQFH RI D VHSDUDWH EXLOGLQJ SHUPLW. 7.IQGLYLGXDO VLJQ SHUPLWV ZLOO EH UHTXLUHG IURP WKH =RQLQJ OIILFH IRU DOO IUHH VWDQGLQJ DQG/RU IDFDGH VLJQV SULRU WR HUHFWLQJ WKH VLJQ DQG PD\ UHTXLUH D VHSDUDWH EXLOGLQJ SHUPLW. UTILITIES 1.TKH ORFDWLRQ RI H[LVWLQJ XWLOLWLHV VKRZQ LQ WKHVH SODQV DUH WDNHQ IURP H[LVWLQJ DYDLODEOH UHFRUGV DQG PD\ QRW EH UHSUHVHQWDWLYH RI H[DFW ORFDWLRQV. IW VKDOO EH WKH FRQWUDFWRUV UHVSRQVLELOLW\ WR YHULI\ WKH H[DFW KRUL]RQWDO DQG YHUWLFDO ORFDWLRQ RI DOO H[LVWLQJ XWLOLWLHV DV QHHGHG SULRU WR FRQVWUXFWLRQ. TKH FRQWUDFWRU VKDOO EH UHVSRQVLEOH IRU WKH GLJJLQJ RI DOO WHVW KROHV WKDW PD\ EH UHTXLUHG ZKHWKHU UHFRPPHQGHG RU QRW E\ WKHVH SODQV WR GHWHUPLQH WKH H[DFW ORFDWLRQ DQG HOHYDWLRQ RI H[LVWLQJ XWLOLWLHV. II DQ\ FRQIOLFWV DULVLQJ IURP WKLV H[LVWLQJ XWLOLW\ YHULILFDWLRQ RU LI GXULQJ WKH FRXUVH RI FRQVWUXFWLRQ DQ\ REMHFW RI DQ XQXVXDO QDWXUH LV HQFRXQWHUHG WKH FRQWUDFWRU VKDOO FHDVH ZRUN LQ WKDW DUHD DQG LPPHGLDWHO\ QRWLI\ GUHHQZD\ EQJLQHHULQJ DW (50) 662-185 DQG/RU WKH SURSHU DXWKRULW\. GUHHQZD\ EQJLQHHULQJ RU DQ\ HQJLQHHU DVVRFLDWHG ZLWK WKHVH SODQV VKDOO QRW EH UHVSRQVLEOH RU OLDEOH IRU DQ\ FRQVWUXFWLRQ FRVW WKDW PD\ EH DVVRFLDWHG ZLWK WKH LQVWDOODWLRQ RU UHLQVWDOODWLRQ DQ\ XWLOLW\ RU RWKHU LPSURYHPHQWV LI QRW QRWLILHG RI DQ\ GLVFUHSDQFLHV EHWZHHQ DFWXDO ILHOG FRQGLWLRQV DQG WKH DSSURYHG SODQ. 2.TKH GHYHORSHU ZLOO EH UHVSRQVLEOH IRU WKH UHORFDWLRQ RI DQ\ H[LVWLQJ XWLOLWLHV ZKLFK PD\ EH UHTXLUHG DV D UHVXOW RI KLV SURMHFW. AQ\ UHTXLUHG UHORFDWLRQ RI H[LVWLQJ XWLOLWLHV VKRXOG EH FRPSOHWHG SULRU WR FRQVWUXFWLRQ. .TKH DHYHORSHU DQG/RU CRQWUDFWRU VKDOO EH UHVSRQVLEOH WR VXSSO\ DOO XWLOLW\ FRPSDQLHV ZLWK FRSLHV RI WKH DSSURYHG SODQV DQG DGYLVH WKHP WKDW DOO JUDGLQJ VKDOO FRQIRUP WR WKH DSSURYHG SODQV DQG IXUWKHU WKDW WKH XWLOLW\ FRPSDQLHV VKDOO EH UHVSRQVLEOH IRU KRQRULQJ WKHVH SODQV DQG WKH ILQLVKHG JUDGHV LQ WKH LQVWDOODWLRQ RI WKHLU XWLOLW\ OLQHV. .AOO SURSRVHG XWLOLWLHV WR EH ORFDWHG XQGHUJURXQG. 5.TKH DHYHORSHU DQG/RU CRQWUDFWRU VKDOO QRWLI\ RSHUDWRUV ZKR PDLQWDLQ XQGHUJURXQG XWLOLW\ OLQHV LQ WKH DUHD RI SURSRVHG H[FDYDWLQJ RU EODVWLQJ DW OHDVW WZR (2) ZRUNLQJ GD\V EXW QRW PRUH WKDQ WHQ (10) ZRUNLQJ GD\V SULRU WR FRPPHQFHPHQW RI H[FDYDWLRQ RU GHPROLWLRQ. 6.TKH GHYHORSHU VKDOO EH UHVSRQVLEOH IRU QRWLI\LQJ FUHGHULFN WDWHU DQG DOO RWKHU DSSURSULDWH XWLOLW\ FRPSDQLHV SULRU WR FRQVWUXFWLRQ RI ZDWHU DQG/RU VDQLWDU\ VHZHU OLQHV. IQIRUPDWLRQ VKRXOG DOVR EH REWDLQHG IURP WKH DSSURSULDWH DXWKRULW\ FRQFHUQLQJ SHUPLWV FXW VKHHWV DQG FRQQHFWLRQV WR H[LVWLQJ OLQHV. 7.AOO VDQLWDU\ VHZHUV ZDWHU PDLQV DQG DSSXUWHQDQFHV VKDOO EH FRQVWUXFWHG LQ DFFRUGDQFH ZLWK WKH FXUUHQW VWDQGDUGV DQG VSHFLILFDWLRQV RI FUHGHULFN WDWHU. 8.WKHQ JUDGLQJ LV SURSRVHG ZLWKLQ HDVHPHQWV RI XWLOLWLHV OHWWHUV RI SHUPLVVLRQ IURP DOO LQYROYHG FRPSDQLHV PXVW EH SURYLGHG WR WKH FUHGHULFN CRXQW\ PXEOLF WRUNV DHSDUWPHQW SULRU WR LVVXDQFH RI JUDGLQJ DQG/RU VLWH GHYHORSPHQW SHUPLWV. .TKH GHYHORSHU VKDOO EH UHVSRQVLEOH IRU DQ\ GDPDJH WR WKH H[LVWLQJ VWUHHWV DQG/RU XWLOLWLHV ZKLFK PD\ RFFXU DV D UHVXOW RI FRQVWUXFWLRQ ZLWKLQ RU FRQWLJXRXV WR DQ H[LVWLQJ ULJKW-RI-ZD\ RU XWLOLW\. 10.AOO VWRUPZDWHU SLSLQJ DQG VWUXFWXUHV VKRZQ RQ WKHVH SODQV DUH RQO\ DFFXUDWH WR WKH LQOHW RU PDQKROH ORFDWLRQV DV VKRZQ KHUHRQ. DHWDLO GHVLJQ RI VWRUPZDWHU VWUXFWXUHV ZHUH QRW SURYLGHG WR GUHHQZD\ EQJLQHHULQJ. AFWXDO SLSH DOLJQPHQWV ZLOO EH EDVHG XSRQ GHYHORSHG VWUXFWXUDO VKRS GUDZLQJV DV SURYLGHG E\ WKH PDQXIDFWXUHU. CRQWUDFWRU VKDOO PDNH DGMXVWPHQWV WR SLSH DOLJQPHQWV EDVH RQ SURYLGHG VKRS GUDZLQJV. GUHHQZD\ EQJLQHHULQJ ZLOO QRW EH KHOG UHVSRQVLEOH RU OLDEOH IRU DQ\ GLVFUHSDQFLHV RU FKDQJHV FDXVHG E\ WKH VWUXFWXUDO GHVLJQ. CRQWUDFWRU PD\ VXEPLW VKRS GUDZLQJV WR GUHHQZD\ EQJLQHHULQJ IRU UHYLHZ DQG DSSURYDO DW FRQWUDFWRU'V H[SHQVH. SKRS GUDZLQJV ZLOO EH UHYLHZHG IRU FRPSOLDQFH ZLWK GHVLJQ SODQV. TKH OZQHU RU DHYHORSHU ZLOO EH UHVSRQVLEOH IRU DQ\ UHGHVLJQ DV D UHVXOW RI VWUXFWXUDO VKRS GUDZLQJ GHVLJQ. 11.AOO SDUNLQJ ORW/VWUHHW OLJKW DQG GU\ XWLOLW\ GHVLJQ VKDOO EH SHUIRUPHG DQG SURYLGHG VHSDUDWHO\ E\ RWKHUV. AOO GU\ XWLOLW\ VWUXFWXUDO EDVH GHVLJQ HOHFWULFDO GHVLJQ SKRWRPHWULFV DQG RU RWKHU OLJKWLQJ LQIRUPDWLRQ VKRZQ KHUHRQ LV DV VSHFLILHG E\ RWKHUV DQG LV LQFOXGHG IRU LQIRUPDWLRQDO SXUSRVHV RQO\ DV GLUHFWHG E\ WKH OZQHU DHYHORSHU DQG/RU SXEOLF DJHQF\ UHTXLUHPHQWV. GUHHQZD\ EQJLQHHULQJ KDV QRW SHUIRUPHG DQ\ OLJKWLQJ DQG/RU GU\ XWLOLW\ GHVLJQ DQG GRHV QRW ZDUUDQW DQG LV QRW UHVSRQVLEOH IRU WKH GHJUHH DQG/RU DGHTXDF\ RI LOOXPLQDWLRQ RQ WKLV SURMHFW RU WKH DGHTXDF\ RI WKH GU\ XWLOLW\ WR VHUYLFH WKH VLWH. AQ\ FKDQJHV WR WKH OLJKWLQJ GHVLJQ RQFH WKH SODQ LV DSSURYHG VKDOO EH DSSURYHG E\ WKH CRXQW\ SULRU WR LQVWDOODWLRQ. SITEWORK 1.Refer to the Geotechnical Engineer Report for methods, materials and details for construction of all earthwork activities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†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¶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¶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¶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¶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¶V LQVSHFWRU. D. AGMXVW FUHGHULFN WDWHU IDFLOLWLHV WR JUDGH DV UHTXLUHG E\ WKH FUHGHULFN WDWHU IQVSHFWRU. 7. FUHGHULFN WDWHU¶V PDLQWHQDQFH GLYLVLRQ VKDOO IXUQLVK DQG LQVWDOO DOO ZDWHU PHWHUV WKURXJK 2 LQFK LQ VL]H. IW LV WKH FRQWUDFWRU¶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ǫ´[ô´ ô´ 1´ 1ò´ DQG 2´ ZDWHU VHUYLFHV LL. DOO VHZHU VHUYLFHV. E. TKH RZQHU/GHYHORSHU VKDOO L. FRRUGLQDWH (RU KDYH WKH FRQWUDFWRU FRRUGLQDWH) WKH ORFDWLRQ RI WKH VHUYLFH ODWHUDO ZLWK FUHGHULFN WDWHU¶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¶V D. GRPHVWLF ZDWHU PHWHU DQG LWV EDFNIORZ SUHYHQWLRQ GHYLFH DQG/RU LWV E. FLUH VHUYLFH OLQH¶V ZDWHU PHWHU DQG EDFNIORZ SUHYHQWLRQ GHYLFH. 12. DE4 PXVW DOVR DSSURYH VHZHU SXPS VWDWLRQV. FUHGHULFN WDWHU UHTXLUHV D FRS\ RI DE4¶V CHUWLILFDWH WR OSHUDWH DQG D FRS\ RI WKH VWDWLRQ¶V DE4 DSSURYHG O M PDQXDO. TKHVH GRFXPHQWV PXVW EH UHFHLYHG EHIRUH VXEVWDQWLDO FRPSOHWLRQ LV LVVXHG DQG ZDWHU PHWHUV UHOHDVHG. OFWREHU 15 202 RHY. NR.DDWH 06 06/2/2026 29Jun2026 GLENRIDGE DRIVETWINBROOK CIRROSSUM LANEMAS O N S T R E E T 30' RO W ( D B 206 PG 459) T.M. 65A-7-7-8A FREDERICK COUNTY SANITATION AUTHORITY DB. 493 PG. 123 T.M. 65B-6-38 ATKINS , MAURICE M. & SHERRY L DB. 582 PG. 756 T.M. 65-A-50 ATKINS , MAURICE M. & SHERRY L DB. 582 PG. 756 T.M. 65-A-54 RUBLE, RANDY LEE & MARY F. T.M. 65B-7-10 RUBLE, RANDY LEE & MARY F. T.M. 65-A-57 KAPLN, JOSHUA A. T.M. 65-A-56 GRANADOS, MEMBRENO JOSE MARBIN T.M. 65-A-60 LAFOND, DANIEL P. & JENIFER T.M. 65-A-62 ROLES, DONALD L. T.M. 65-A-63 FELTNER, PAT O. & PAMELA H. T.M. 65-A-70 PUFFINBURGER, PAUL R. T.M. 65-A-66 FEATHERS, VICKY LYNN & RICHARD A. DB. 957 PG. 979 T.M. 65-A-65 SPEAKMAN, DONALD R. & KAREN M. T.M. 65-A-71 CATHY M. MALICK C/O CAPON VALLEY BANK / LOAN DEPARTMENT T.M. 65D-1-1 HENRIQUEZ MAJANO JOSE F., ETALS T.M. 65D-2-4FELTNER, JEFFREY IIIT.M. 65D-2-5123 RENTALS LLCT.M. 65D-2-6123 RENTALS LLCT.M. 65D-2-7ENDICOTT, KAITLYNT.M. 65D-2-8TAYLOR, MICKEY W. &TAYLOR, LISA A.T.M. 65D-2-9 JENNINGS INVESTMENTS LLC T.M. 65D-2-10A GLENMONT VILLAGE ASSOCIATION D.B. 614 PG. 802 T.M. 65D-1-3-37A GLENMONT VILLAGE ASSOCIATION D.B. 583 PG. 137 T.M. 65D-3-4-59A GLENMONT VILLAGE ASSOCIATION D.B. 614 PG. 802 T.M. 65D-3-4-53 WAMPLER, JORDAN K. & PORTER, MAKAYLA A. T.M. 65D-3-4-54 MCDONALD R G PROPERTIES LC D.B. 966 PG. 1528 T.M. 65D - 4 - 5 - 7 1 HOLTHA U S , CHRIST O P H E R W . & MARTIN E Z , G A B R I E L A T.M. 65D - 5 - 6 - 7 6 MCKEE, R I C H A R D VAUGH N & MCKE E , D A W N T.M. 65D - 5 - 6 - 7 7 KAWSA R , A F L A T O O N T.M. 65D - 5 - 6 - 7 8 STUIT, D A N A R . & STUIT T H E R E S A L . T.M. 65D - 5 - 6 - 7 9 STOUPA , M I C H A E L , & STOU P A , A S H L E Y T.M. 65D - 5 - 6 - 80 TIFFAN Y , K E I T H OLIVER T.M. 6 5 D- 5- 6- 81 FRA S E, J E R R Y ROG E R T R U S T E E FRA S E, P A T RI CI A J. TRU S T E E T.M. 6 5 D- 5- 6- 8 2 PIER C E, J U S TI N T.M. 6 5 D- 5- 6- 8 3 NES S E L R O D T, DON A L D E. D.B 7 2 2 P G. 7 1 6 T.M. 6 5 D- 5- 6- 8 4 FOR D, R E C O R D O T. & FO R D C R Y S T A L D. T.M. 6 5 D- 5- 6- 8 5 ROS S, KI M V. & ROS S C A R O L Y N S. D.B. 7 2 4 P G. 1 8 T.M. 65 D-5-6-86 RAM OS, JE N NIFE R.T.M. 65 D-5-6-87FOX, A N GELA J. &FOX, E RI C F. T.M.65D-5-6-88 O'HARA, DANIEL & O'HARA MONICA INST. NO 030011096 ZONE: RP USE: URBAN RESIDENTIAL T.M.65D-5-6-89 ADAMS, GARY LINDEN & ADAMS, JUNAITA SPIELMAN D.B.725 PG. 724 ZONE: RP USE: URBAN RESIDENTIAL T.M. 65-A-49B US HOME CORPORATION 18.59 AC INST# 220001195 ZONE: RP T.M.65-A-55 US HOME CORPORATION 55.24 AC INST# 20 0008114 ZONE: RP USE: RESIDENTIAL 35' RIPARIAN BUFFER 35' RIPARIAN BUFFER 35' RIPARIAN BUFFER 35' RIPARIAN BUFFER 35' RIPARIAN BUFFER 35' RIPARIAN BUFFER EX. STREAM EX. STREAM EX. STREAM EX. STREAM EX. STREAM EX. STREAM 35' RIPARIAN BUFFER 35' RIPARIAN BUFFER 35' RIPARIAN BUFFER 35' RIPARIAN BUFFER 35' RIPARIAN BUFFER 35' RIPARIAN BUFFER DELINEATED WETLANDS DO NOT DISTURB WITHOUT ACOE PERMIT (0.3 ACRES) RTE. 37 R/W DEDICATION PER PROFFER #C5 2016 GIS ALIGNMENT AREA VDOT RTE. 37 RTE. 37 RESERVATION AREA T.M. 65-A-186J WENCE, DANE MATTHEW & SARAH ANN INST. NO 150011940 ZONE: RA USE: RESIDENTIAL T.M. 65-A-186B WERDEBAUGH RONALD F. & MELANIE J. DB. 969 PG. 1563 ZONE: RA USE: RESIDENTIAL T.M. 65-A-190 DAVIS, WILMER R. & DONNA N. INST. NO 060024340 ZONE: RA USE: VACANT T.M. 65-A-72 EFG INVESTMENTS LLC DB. 955 PG. 724 ZONE: RA USE: VACANT T.M. 65-A-186M WERDEBAUGH QUINTON T & TORREY PRISCILA G INSTR. NO 220013241 ZONE: RA USE: RESIDENTIAL N/A 3 05/15/2025 ZJ, KAS ---- 51 3924L 2. Aerial, horizontal, and vertical control surveys were Dated: 3. Aerial topographic mapping performed by: 1. Boundary survey was performed by: performed by: (Year) Dated:GREENWAY ENGINEERING 01-05-05 / Updated 06-18-2020 2005GREENWAY ENGINEERING VIRGINIA MAPPING INC.2005 SURVEY AND TOPOGRAPHIC INFORMATION BOUNDARYRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE II151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV120 0 120 240 SCALE: 1" = 120' 60 Rev. No.Date 03 12/19/2025 06Feb2026 LOT 2 LOT 1 LOT 29 LOT 30 LOT 78LOT 77LOT 76LOT 71LOT 61 LOT 62 LOT 31 LOT 32 LOT 33 LOT 34 LOT 35 LOT 36 LOT 37 LOT 38 LOT 39 LOT 46 LOT 40 LOT 41 LOT 42 LOT 43 LOT 44 LOT 45 LOT 24 LOT 28 LOT 27 LOT 26 LOT 25 LOT 17 LOT 23 LOT 22 LOT 21 LOT 20 LOT 19 LOT 18 LOT 8 LOT 9 LOT 16 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 10 LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 LOT 75LOT 74LOT 73LOT 72LOT 70LOT 63LOT 69LOT 68LOT 67LOT 66LOT 65LOT 64LOT 55 LOT 60 LOT 59 LOT 58 LOT 57 LOT 56 LOT 54 LOT 47 LOT 53 LOT 52 LOT 51 LOT 50 LOT 49 LOT 48L1L2L 3 L4 L5 L6L7L8L9L10 L11 L12 L13L14L15 C1C3C4L16L17L18C5C6 L19L22L23L24 L25 L26L27L28 C7C8C9 C10L20 L21 RIVANNA PL . (PRIVATE )GAP RUN DR .(PRIVATE)GAP RUN D R . (PRIVAT E )RIVANNA PL.(PRIVATE)LEHIGH DR .VAR R/WLEHIGH DR .(PRIVATE)C2OPEN SPACE = 20,626 SF OPEN SPACE = 422,631 SF OPEN SPACE = 422,631 SF OPEN SPACE = 422,631 SF LINE BEARING DISTANCE L19 S 03°09'54" E 65.98' L22 S 03°09'54" E 100.65' L23 S 17°22'05" W 82.86' L24 S 85°56'36" W 383.11' L25 N 71°05'35" W 23.88' L26 N 20°13'20" E 143.31' L27 N 20°13'20" E 177.26' L28 N 87°28'55" E 14.43' CURVE RADIUS ARC LENGTH CHORD LENGTH CHORD BEARING DELTA ANGLE TANGENT DEGREE OF CURVE C7 80.00'28.67'28.52'S 07°06'06" W 20°31'59.0"14.49'21°49'47.0" C8 80.00'95.75'90.14'S 51°39'20" W 68°34'30.6"54.55'21°49'47.0" C9 80.00'32.06'31.85'N 82°34'29" W 22°57'49.6"16.25'21°49'47.0" C10 150.00'176.09'166.15'N 53°51'08" E 67°15'35.2"99.77'11°38'33.1" PRIVATE CENTERLINE DATAPRIVATE CENTERLINE CURVE DATA LINE BEARING DISTANCE L1 S 05°23'00" E 5.95' L2 S 09°38'32" E 88.57' L3 S 40°51'03" E 88.95' L4 N 80°01'48" E 56.27' L5 S 62°46'52" E 105.30' L6 S 03°31'18" E 67.35' L7 S 57°06'57" W 212.57' L8 N 35°59'19" W 173.76' L9 N 51°35'21" W 54.19' L10 N 16°48'16" E 54.49' L11 N 67°05'01" E 91.41' L12 N 68°22'11" E 36.19' L13 N 80°21'28" E 28.36' L14 N 09°38'32" W 82.13' L15 N 05°23'00" W 5.95' L20 N 87°28'55" E 320.18' L21 N 87°28'55" E 98.49' CURVE RADIUS ARC LENGTH CHORD LENGTH CHORD BEARING DELTA ANGLE TANGENT DEGREE OF CURVE C1 575.00'42.74'42.73'S 07°30'46" E 4°15'31.3"21.38'3°02'13.9" C2 1025.00'12.80'12.80'S 09°17'03" E 0°42'56.4"6.40'1°42'13.6" C3 61.50'262.48'104.00'N 79°33'20" W 244°32'25.7"97.40'28°23'47.1" C4 625.00'46.46'46.44'N 07°30'46" W 4°15'31.3"23.24'2°47'39.1" LINE BEARING DISTANCE L16 S 05°18'00" E 5.08' L17 S 09°38'32" E 88.56' L18 S 03°09'54" E 61.50' CURVE RADIUS ARC LENGTH CHORD LENGTH CHORD BEARING DELTA ANGLE TANGENT DEGREE OF CURVE C5 600.00'45.47'45.46'S 07°28'16" E 4°20'31.2"22.75'2°54'38.3" C6 1000.00'321.04'319.66'S 00°26'42" E 18°23'39.3"161.91'1°44'47.0" PUBLIC RIGHT OF WAY DATA PUBLIC RIGHT OF WAY CURVE DATA PUBLIC CENTERLINE DATA PRIVATE CENTERLINE CURVE DATA PUBLIC CENTERLINE CURVE DATA 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV1"=80' 4 05/15/2025 ZJ, KAS ---- 51 3924L LEGEND PUBLIC R/W PRIVATE R/W 80 0 80 160 SCALE: 1" = 80' 40 NOTE: ROAD RIGHT-OF-WAY TO BE MARKED PER VDOT STANDARD RM-2.RIGHT-OF-WAYRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 03 12/19/2025 06Feb2026 ØØØØØØØØØØØØØØØØXXXXXXXX XX XX XX XX XX XX XX XX XX XX XX XX XXXX XXXXXXXXXXXXXXXXXX XX XX XXXXXX CFS CFS CFSCFS CFS1.5:11.5:12:11.5:1ØØØØØ ØØØØCE CD ST#1 DDDD DDDD DDDD OP CFS CFS LCG SSF LCG LCG LCG SSF SSF SSF SSF SSF SSF SSF 58 92 INV 58 68 INV TS TS TS TS TS LCG LCG LCG LCG LCG LCG LCG LCG LCG LCG Ø Ø Ø Ø TS TS DDDD TS DDDD TS LCG LCG LCG RWD RWD RWD RWD RWD RWDCFS C F S CF S CF S CFS CFSØCFS RWD RWD RWD ØØIP 21 CC 300 301 302 151 AA BB PS1 PS2 147148149 152 150 20B 20A 20 LCG 19.1% 1.09% 10.0' 1.09%6.0'3.0 '4.0'1 9 . 3% T.M. 65-A-190 DAVIS, WILMER R. & DONNA N. T.M. 65-A-49B US HOME CORPORATION 18.59 AC INST# 22 0001195 ZONE: RP T.M. 65-A-72 EFG INVESTMENTS LLC DB. 955 PG. 724 WORK/SUMP AREA TO BE DEWATERED UTILIZING FILTER BAG OR DEWATERING STRUCTURE WITH ADEQUATE VOLUME FOR THE PUMP RATE(16XGPM=FT3). REFER TO E&S DETAILS AND VA E&S HANDBOOK. 3 - 30" ADS N12 CULVERTS, 50' @ 0.6%, INLETS TO BE MITERED TO CONFORM TO SLOPE FOR INLET CAPACITY, SEE TEMPORARY STREAM CROSSING DETAIL. CLASS A1 RIP RAP VDOT #1 AGGREGATE TEMPORARY DIVERSION CHANNEL, SEE DETAIL, CLASS B LINING PHASE 1A LIMITS OF DISTURBANCE AREA TO ST #1 DA= 1.68 AC. PHASE 1A LIMITS OF DISTURBANCE EXTEND DIVERSION DIKES AS BORROW AREA DISTURBANCE GROWS BORROW AREA FOR FILL MATERIAL PROPOSED BOX CULVERT, SEE SHEETS 30 & 31 FOR PROFILE AND DETAILS.590588 586 584 582 578 576574 572570 568566 564 580 56 4 560562558 560 560 558 558 560 562 564 566568 570 572 574 57657858058258 4 58 6 588590592594596598600602 604 606 608 610612614616618620622624626628630632634636638614616618620622624626628630612606.25603.75603.75606.25609608606604608606609609608606604610558 558 556 556558 560 558 556 610576 556 556 562 4.0'11.0 ' 11' STONE OUTLET PER TRAP DETAIL BASE OF STONE/TOP OF WET STORAGE = 605.75 TOP OF STONE/TOP OF DRY STORAGE = 608.00 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV1" = 40' 5 05/15/2025 ZJ, KAS ---- 51 3924L AREA OF CONCERN - CONTRACTOR TO INVESTIGATE CONDITIONS FOR STABILITY AND CONSULT WITH A GEOTECHNICAL ENGINEER FOR STRUCTURAL FILL REQUIREMENTS SHOULD IT BE DETERMINED AREA IS UNSTABLE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE X X X Ø SUPER SILT FENCE TEMPORARY SEDIMENT TRAP TEMPORARY DIVERSION DIKE CULVERT INLET PROTECTION ROCK CHECK DAMS SILT FENCE LIMITS OF CLEARING AND GRADING OUTLET PROTECTION NO. KEY SYMBOL DESCRIPTION 3.13 3.09 3.08 3.20 3.05 3.18 3.02 LCG OP ST DD CIP SSF SF CE CD 3.32 PS PERMANENT SEEDING IP STORM DRAIN INLET PROTECTION3.07 3.36 B/M SOIL STABILIZATION BLANKETS & MATTING EROSION/SEDIMENT CONTROL LEGEND TEMPORARY SEDIMENT BASIN3.14 SB 3.31 TS TEMPORARY SEEDING SEEDING X X XX X X Ø Ø TEMPORARY ROW DIVERSION3.11 RWD COMPOST FILTER SOCKCFSCFS CARRYING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. IS THE PARTY RESPONSIBLE FOR THE RESPONSIBLE LAND DISTURBER DATE: CERTIFICATION #: NAME: RESPONSIBLE LAND DISTURBER NOTES: 1.FOR FILLS IN AREAS OF PROPOSED STRUCTURES, (ROADWAYS, RESIDENTIAL DWELLINGS, RETAINING WALL, ETC.), PLEASE SEE CURRENT GEOTECHNICAL REPORT FOR MINIMUM CONTROLLED FILL REQUIREMENTS. ALL CONTROLLED FILLS SHALL BE PLACED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT AND COORDINATED WITH THE DEVELOPER'S GEOTECHNICAL ENGINEER. 2.PERIMETER CONTROLS ARE TO BE COMPLETELY INSTALLED PRIOR TO STARTING CONSTRUCTION OF SEDIMENT TRAPS AND SEDIMENT BASINS 3.DIVERSION DIKES ARE TO BE MAINTAINED DAILY AS THE AREA IS GRADED 4.EXISTING BMP'S TO REMAIN PROTECTED FROM SEDIMENT AT ALL TIMES. NARRATIVE: E&S PHASE 1A PROPOSES TO DIVERT STREAM AND INSTALL PERMANENT STREAM CROSSING. PERMANENT LOW FLOW CULVERT TO BE FULLY INSTALLED AND FLANKING CULVERTS TO BE AT LEAST PARTIALLY INSTALLED TO FACILITATE CONSTRUCTION ACCESS ROAD TO SITE OVER THE PERMANENT CULVERTS. FOR PHASE I EROSION AND SEDIMENT CONTROL ONLY !!E&S PHASE IARED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE II40 0 40 80 SCALE: 1" = 40' 20 Rev. No.Date 02 07/31/2025 06Feb2026 XXØØXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXØØ Ø Ø Ø Ø 5 4 3 2 1 LCG LCG LCG LCG LCG LCG LCG LCG LCG LCG LCG LCG CE XXXXXXXXXXXXXX XXXXXXXX XX XXX X ØØØØØØØØØØØØØØØØØDDDD TSØØØØØØØØØØØØ TSD TSD AREA TO TSD =0.97 AC. IP AREA TO TSD =0.97 AC. CIP CIP CFS CFS CFS CFS CFS CFS CFS CFS CFS CFS DDDD TS DDDD TS DDDD TS DDDD TS DDDD DDDD DDDD PS PS PS PS PS PS PS PS PS TS TS OP OP OP SB#1 SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF DDDD TS PROPOSED BOX CULVERT, SEE SHEETS 30 & 31 FOR PROFILE AND DETAILS. SSF T.M. 65-A-49B US HOME CORPORATION 18.59 AC INST# 22 0001195 ZONE: RP T.M. 65-A-72 EFG INVESTMENTS LLC DB. 955 PG. 724 INITIAL LIM I T S O FCLEARING A N D G R A D I N G . PH1 E&S C O N T R O L S T O B E 22 21 CC 300 301 302 103 151 AA BB PS1 PS2 147148149 152 150 20B 20A 20 XX XX XX XX XX592590 596598600602604594605.50605.50605.50 605.50 605.50605.50599.75599.75599.75598.75598.25598.255985 9 8 5 9 6 588590592594604602606608602600 604 606570 57 0 604602600604 602 600 599.95599.95599.95 599.95568 582 584 604 56 6 602 600 598 596 594 592 590 588 586 580 578 576 574 572 570 558 556 556 560562564566568XX570566564 558 55 8 568 572610612614616618620622624626628632634636638610610608630DDDD 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV1" = 30' 6 05/15/2025 ZJ, KAS ---- 51 3924L AREA OF CONCERN - CONTRACTOR TO INVESTIGATE CONDITIONS FOR STABILITY AND CONSULT WITH A GEOTECHNICAL ENGINEER FOR STRUCTURAL FILL REQUIREMENTS SHOULD IT BE DETERMINED AREA IS UNSTABLE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE X X X Ø SUPER SILT FENCE TEMPORARY DIVERSION DIKE CULVERT INLET PROTECTION ROCK CHECK DAMS SILT FENCE LIMITS OF CLEARING AND GRADING OUTLET PROTECTION NO. KEY SYMBOL DESCRIPTION 3.09 3.08 3.20 3.05 3.18 3.02 LCG OP DD CIP SSF SF CE CD 3.32 PS PERMANENT SEEDING IP STORM DRAIN INLET PROTECTION3.07 3.36 B/M SOIL STABILIZATION BLANKETS & MATTING EROSION/SEDIMENT CONTROL LEGEND TEMPORARY SEDIMENT BASIN3.14 SB 3.31 TS TEMPORARY SEEDING SEEDING X X XX X X COMPOST FILTER SOCKCFSCFS TEMPORARY SLOPE DRAINTSD3.15 MATCH LINE SEE SHEET 7 CARRYING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. IS THE PARTY RESPONSIBLE FOR THE RESPONSIBLE LAND DISTURBER DATE: CERTIFICATION #: NAME: RESPONSIBLE LAND DISTURBER NOTE: 1.FOR FILLS IN AREAS OF PROPOSED STRUCTURES, (ROADWAYS, RESIDENTIAL DWELLINGS, RETAINING WALL, ETC.), PLEASE SEE CURRENT GEOTECHNICAL REPORT FOR MINIMUM CONTROLLED FILL REQUIREMENTS. ALL CONTROLLED FILLS SHALL BE PLACED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT AND COORDINATED WITH THE DEVELOPER'S GEOTECHNICAL ENGINEER. 2.PERIMETER CONTROLS ARE TO BE COMPLETELY INSTALLED PRIOR TO STARTING CONSTRUCTION OF SEDIMENT TRAPS AND SEDIMENT BASINS 3.DIVERSION DIKES ARE TO BE MAINTAINED DAILY AS THE AREA IS GRADED 4.EXISTING BMP'S TO REMAIN PROTECTED FROM SEDIMENT AT ALL TIMES. FOR PHASE I EROSION AND SEDIMENT CONTROL ONLY !!E&S PHASE IRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE II30 0 30 60 SCALE: 1" = 30' 15 Rev. No.Date 02 07/31/2025 06Feb2026 XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXX XX XX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX5 LCG LCG LCG LCG ØØØØØØØØØØØØØØØØØØØDDDD TSCFS CFSCFSCFSCFS PS PS PS TS TS AREA TO SEDIMENT BASIN #1 =18.27 SB#1 SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF DDDD TS T.M. 65-A-186J WENCE, DANE MATTHEW & SARAH ANN T.M. 65-A-186B WERDEBAUGH RONALD F. & MELANIE J. DB. 969 PG. 1563 T.M. 65-A-190 DAVIS, WILMER R. & DONNA N. T.M. 65-A-72 EFG INVESTMENTS LLC DB. 955 PG. 724 INITIAL LIMITS OF CLEARING AND GRADING. PH1 E&S CONTROLS TO BE INSTALLED PRIOR TO DISTURBANCE IN THIS AREA LCG LCG LCG LCG LCG LCG LCG LCG LCG INITIAL LIMITS OF CLEARING AND GRADING. PH1 E&S CONTROLS TO BE INSTALLED PRIOR TO DISTURBANCE IN THIS AREA FILL BORROW AREA XX SEE SHEET 24 FOR ADDITIONAL EMBANKMENT CONSTRUCTION DETAILS592590596598600602604594605.50605.50605.50 605.50 605.50605.50599.75599.75599.75599.75 5 9 8 . 7 5598.25598.25598.255985985805825845865885905925945965 9 8 5 9 6 588590592594604602606608602600 604 606604602600604602600604 602 600 599.95599.95599.95 599.95604 602 600 598 596 594 610612614616618620622624626628632634636638614616618620622624626628630612610610608610630DDDD 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV1" = 30' 7 05/15/2025 ZJ, KAS ---- 51 3924L MATCH LINE SEE SHEET 6 AREA OF CONCERN - CONTRACTOR TO INVESTIGATE CONDITIONS FOR STABILITY AND CONSULT WITH A GEOTECHNICAL ENGINEER FOR STRUCTURAL FILL REQUIREMENTS SHOULD IT BE DETERMINED AREA IS UNSTABLE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE X X X Ø SUPER SILT FENCE TEMPORARY DIVERSION DIKE CULVERT INLET PROTECTION ROCK CHECK DAMS SILT FENCE LIMITS OF CLEARING AND GRADING OUTLET PROTECTION NO. KEY SYMBOL DESCRIPTION 3.09 3.08 3.20 3.05 3.18 3.02 LCG OP DD CIP SSF SF CE CD 3.32 PS PERMANENT SEEDING IP STORM DRAIN INLET PROTECTION3.07 3.36 B/M SOIL STABILIZATION BLANKETS & MATTING EROSION/SEDIMENT CONTROL LEGEND TEMPORARY SEDIMENT BASIN3.14 SB 3.31 TS TEMPORARY SEEDING SEEDING X X XX X X COMPOST FILTER SOCKCFSCFS TEMPORARY SLOPE DRAINTSD3.15 CARRYING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. IS THE PARTY RESPONSIBLE FOR THE RESPONSIBLE LAND DISTURBER DATE: CERTIFICATION #: NAME: RESPONSIBLE LAND DISTURBER NOTE: 1.FOR FILLS IN AREAS OF PROPOSED STRUCTURES, (ROADWAYS, RESIDENTIAL DWELLINGS, RETAINING WALL, ETC.), PLEASE SEE CURRENT GEOTECHNICAL REPORT FOR MINIMUM CONTROLLED FILL REQUIREMENTS. ALL CONTROLLED FILLS SHALL BE PLACED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT AND COORDINATED WITH THE DEVELOPER'S GEOTECHNICAL ENGINEER. 2.PERIMETER CONTROLS ARE TO BE COMPLETELY INSTALLED PRIOR TO STARTING CONSTRUCTION OF SEDIMENT TRAPS AND SEDIMENT BASINS 3.DIVERSION DIKES ARE TO BE MAINTAINED DAILY AS THE AREA IS GRADED 4.EXISTING BMP'S TO REMAIN PROTECTED FROM SEDIMENT AT ALL TIMES. FOR PHASE I EROSION AND SEDIMENT CONTROL ONLY !! 30 0 30 60 SCALE: 1" = 30' 15 E&S PHASE I (2)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 02 07/31/2025 06Feb2026 XXXXXX XXXXXXXX XX XXX X ØØØØØ Ø Ø Ø Ø Ø Ø CFSCFS CFS CFSCFSCFSCFS CFS 5 4 3 2 1 LCG LCG LCG LCG CFS CFS DDDD PS PS PS PS PS PS TS TS OP SB#1 SSF SSF DDDD TS 610612614616618620622624614616618620622624626628612610610AREA TO SEDIMENT BASIN #1 =18.27 566 570572574 576 578580 582584586 588590 592 594596598600 602 604 592590596598600602604594605.50605.50605.50 605.50 605.50605.50599.75599.75599.75599.75 5 9 8 . 7 5598.25598.25598.255985985805825845865885905925945965 9 8 5 9 6 588590592594604602606608602600 604 606608610568570564566568 56 8 604602600604602600604 602 600 599.95599.95599.95 599.95T.M. 65-A-72 EFG INVESTM E N T S L L C DB. 955 PG. 7 2 4 1 5 . 0 ' 1 5 . 0 ' SEE SHEET ## FOR PROFILE OF STORM STR. 1-5. 8" ORIFICE SEDIMENT CLEAN OUT LEVEL 597.00 WET STORAGE 599.75 DESIGN HIGH WATER** (25YR STORM) = 603.01 DRY STORAGE 602.005975 9 7 597568 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV1" = 30' 8 05/15/2025 ZJ, KAS ---- 51 3924L NOTES: 1.SEE PHASE II E&S SHEETS 9 & 10 FOR BASIN GRADING UTILIZED IN VOLUMES ANALYSIS. BASIN NOT TO BE CONVERTED AND FINAL GRADED FOR WET POND UNTIL DRAINAGE AREA IS FULLY STABILIZED. 2.SEE SHEET 24 FOR ADDITIONAL EMBANKMENT CONSTRUCTION DETAILS. SEDIMENT BASIN #1 CONVERSION TO WET POND NOTES: 1.INSTALL PRINCIPAL RISER , OUTLET PIPE, AND DAM EMBANKMENT AS SHOWN ON E&S PHASE I SHEETS. 2.DURING E&S PHASE, WHILE IN USE AS A SEDIMENT BASIN, THE PRINCIPAL RISER SHALL INCLUDE PERFORATED POLY DRAIN TUBING CONNECTED TO THE LOW FLOW ORIFICE PER VA E&S HANDBOOK REQUIREMENTS. 3.TO CONVERT FROM SEDIMENT BASIN TO SWM BASIN, DEWATER BASIN AS NECESSARY USING PUMPED WATER FILTER BAG. REMOVE ALL ACCUMULATED SEDIMENT FROM THE BOTTOM OF THE BASIN. REGRADE BASIN BOTTOM TO MATCH PROPOSED GRADING PLAN. REMOVE POLY TUBING AND INSTALL TRASH/DEBRIS RACK OVER LOW FLOW ORIFICE. MIN. 2.0' SEE SHEETS ## & 24 FOR PIPE PROFILES CARRYING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. IS THE PARTY RESPONSIBLE FOR THE RESPONSIBLE LAND DISTURBER DATE: CERTIFICATION #: NAME: RESPONSIBLE LAND DISTURBER 24" RCP (W.T. JOINTS) 5' 0.75' TOP OF RISER ELEV = 602.00 TYP.TRASH RACK BY PLASTIC SOLUTION OR APPROVED EQUAL ELEV = 585.50 8" ORIFICE = 599.75 6.67' 1.83' MINIMUM PRECAST RCP BASE AND RISER STRUCTURE (VDOT A4 CONCRETE) MIN 6" THICK WALL SEDIMENT BASIN #1/ POND #3 PRINCIPAL RISER SECTION NTS CONCRETE FILL FOR BUOYANCY WET STORAGE = 599.75 TOP OF EMBANKMENT ELEV = 605.50 100 YR WS = 603.68 10" PERFORATED POLY DRAINAGE TUBING FOR E&S SEE SHEETS 34 & 24 FOR PIPE PROFILES AND ADDITIONAL RISER INFORMATION INV FOR PIPE DRAIN TO BE SEALED DURING USE AS BASIN IF PRECASTED INTO STRUCTURE 30 0 30 60 SCALE: 1" = 30' 15 SEDIMENT BASIN DETAILSRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 02 07/31/2025 06Feb2026 XXXX10+00 11+00 12+00 13+00 13+80.77 OP OP OP OP OP OP IP IP IP IPIP IP IP IP OP IP IP IP IP IP IP IP 1 5 . 0 0 ' 1 5 . 0 0 '594596598598.25599.75599.95605.5602604598.7 5 599.7 5600593.2559 6 598 594 8" ORIFICE WET STORAGE 599.75 LOT 2 LOT 1 LOT 8 LOT 9 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 10 LOT 11 LOT 12 149 149A 149B 149E 149D149C 32 33 JF 31 30 31A 31B 3534 4 3 2 1 BMP #1 / WET POND 3 BMP #3 / JELLYFISH STORM DRAINAGE ESMT.LEHIGH DR.(PRIVATE)LEHIGH DR.(PRIVATE)IP LOT 16 LOT 15 LOT 14 LOT 13 5 GRID MERIDIANVA NORTH ZONE NAD835 5 8 556 556 558 55 8 634632630636638640642605.56 1 2 6 1 8 6 1 6 6 1 4610 620 622 624 620 622624618 616 626 628 626 6126166146 1 0 60 8 60 6 6 0 4 60 2 602584586588590592594596598600626626560562564566568570572574576578580582584586584582580578576574572570568566564 568 570572 574 576 578 580 582 584 588 590 592 594 596 598 600 602 604 58859259459659860260059025 18 26 5223852252 21 18185217181985 17 06 18 40 19 73 21 06 22 40 23 73 25 06 26 40 23 521063 14 86 16 46 17 87 19 28 20 70 22 11 24 76 24 86 24 86 24 86 24 86 25 25 25 25 25 62 25 99 26 45 29 732907 28 402773 27 732707 26 402640 29 852652 26 52 27 19 27 85 27 85 28 52 29 19 24 53 24 36 SENSENY VILLAGE PHASE 1 SHOWN PER APPROVED SUBDIVISION DESIGN PLANS PS PS PS PS PS PSSSFSSFSSFSSF SSFSSFSSFSSFSSFSSFSSFSSF SSF SSF SSF SSF LCG LCG LCG LCG LCG LCG LCG LCG LCG LCG LCG LCG PS SSF SSF SSF SSF CFS CFS SSF SSF CFS CFS CFS CFSCFS CFS CFS CFS CFS CFS CFS TO STR. #35 DA=0.13 AC. C=0.55 TO STR. #32 DA=0.12 AC. C=0.79 TO STR. #33 DA=0.25 AC. C=0.58 TO STR. #149D DA=0.15 AC. C=0.74 TO STR. #149C DA=0.16 AC. C=0.73 TO STR. #149B DA=0.07 AC. C=0.72 TO STR. #149E DA=0.09 AC. C=0.75 TO STR. #149 DA=0.07 AC. C=0.76 TO STR. #149A DA=0.13 AC. C=0.65 TO STR. #34 DA=0.19 AC. C=0.54 CFS CLASS 1 RIPRAP, SEE DETAIL SHEET 30 CLASS 1 RIPRAP, SEE DETAIL SHEET 30 CLASS A1 RIPRAP SSFSSFSSFSSFSSFSSFSSFSSFSSFSSFCL A1 RIPRAP 16'L X 10'W X 18"D NOTES: 1.FOR FILLS IN AREAS OF PROPOSED STRUCTURES, (ROADWAYS, RESIDENTIAL DWELLINGS, RETAINING WALL, ETC.), PLEASE SEE CURRENT GEOTECHNICAL REPORT FOR MINIMUM CONTROLLED FILL REQUIREMENTS. ALL CONTROLLED FILLS SHALL BE PLACED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT AND COORDINATED WITH THE DEVELOPER'S GEOTECHNICAL ENGINEER. 2.PERIMETER CONTROLS ARE TO BE COMPLETELY INSTALLED PRIOR TO STARTING CONSTRUCTION OF SEDIMENT TRAPS AND SEDIMENT BASINS. 3.DIVERSION DIKES ARE TO BE MAINTAINED DAILY AS THE AREA IS GRADED. 4.EXISTING BMP'S TO REMAIN PROTECTED FROM SEDIMENT AT ALL TIMES. 5.SLOPES 3:1 AND GREATER SHALL BE PROTECTED WITH SOIL STABILIZATION BLANKETS (EC-2). 6.REFER TO SHEET 50B FOR DITCH SECTIONS. 7.REFER TO SHEET 78 FOR OUTLET PROTECTION COMPUTATIONS. 8.THE RUNOFF REDUCTION COMPLIANCE FOREST/OPEN SPACE AREA IS NOT TO BE DISTURBED DURING CONSTRUCTION AND SHOULD BE FENCED OFF WHEN INSTALLING INITIAL EROSION AND SEDIMENT CONTROL MEASURES. 9.REFER TO SHEET 10A FOR SEDIMENT TRAP DETAILS AND COMPUTATIONS.151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV603001530 SCALE: 1" = 30' 1" = 30' 9 05/15/2025 ZJ, KAS ---- 51 3924LFOR PHASE II EROSION AND SEDIMENT CONTROL ONLY !!CARRYING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. IS THE PARTY RESPONSIBLE FOR THE RESPONSIBLE LAND DISTURBER DATE: CERTIFICATION #: NAME: RESPONSIBLE LAND DISTURBER NO. KEY SYMBOL DESCRIPTION EROSION/SEDIMENT CONTROL LEGEND COMPOST FILTER SOCKC-PCM-05 CFS SILT FENCEC-PCM-04 SUPER SILT FENCEC-PCM-04 SSF SF TEMPORARY DIVERSION DIKEC-ECM-04 DD SAFETY FENCEC-PCM-01 SAF CFS SF SSF ROCK CHECK DAMSC-SCM-07 TEMPORARY SLOPE DRAINC-ECM-12 CD TSD STORMWATER CONVEYANCE CHANNELC-ECM-09 SCC STORM DRAIN INLET PROTECTIONC-SCM-04 IP CULVERT INLET PROTECTIONC-SCM-05 CIP TEMPORARY SEDIMENT BASINC-SCM-12 SB OUTLET PROTECTIONC-ECM-15 OP ROCK FILTER OUTLETC-SCM-08 RFO TEMPORARY GRAVEL CONSTRUCTION ENTRANCEC-SCM-03 CE STABILIZATION BLANKETS AND MATTINGC-SSM-05 PSC-SSM-09 TEMPORARY SEEDINGTS PSC-SSM-10 PERMANENT SEEDINGPS C-SCM-10 DS DEWATERING STRUCTURE B/M LIMITS OF CLEARING & GRADINGLCG DRAINAGE DIVIDES CRITICAL SLOPE - CRITICAL SLOPE TO BE SEEDED, MULCHED AND TACKED WITHIN 14 DAYS AFTER START OF GRADING, OR SODDED AND PEGGED WITHIN 14 DAYS AFTER START SLOPE STABILITY ANALYSIS SHALL BE REQUIRED (TO BE PROVIDED BY CONTRACTOR) FOR ROAD FILL EMBANKMENTS GREATER THAN 10' PER VDOT REQUIREMENTS. MATCH LINE S E E S H E E T ##E&S PHASE IIRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 02 07/31/2025 06Feb2026 OP OP OP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP594596598598.25599.75599.95605.5602604598. 7 5 599. 7 5 599. 9 5 600 606 602 604 608 610600593.2559 6 5985941 5 . 0 0 ' 1 5 . 0 0 ' 8" ORIFICE SEDIMENT CLEAN OUT LEVEL 597.00 WET STORAGE 599.75 DESIGN HIGH WATER** (25YR STORM) = 603.01 DRY STORAGE 602.00 T.M. 65-A-72 EFG INVESTMENTS LLC DB. 955 PG. 724 GRID MERIDIANVA NORTH ZONE NAD83LOT 2 LOT 1 LOT 29 LOT 30LOT 77 LOT 76 LOT 71 LOT 61 LOT 62 LOT 31 LOT 32 LOT 33 LOT 34 LOT 35 LOT 36 LOT 37 LOT 38 LOT 39 LOT 46 LOT 40 LOT 41 LOT 42 LOT 43 LOT 44 LOT 45 LOT 24 LOT 28 LOT 27 LOT 26 LOT 25 LOT 17 LOT 23 LOT 22 LOT 21 LOT 20 LOT 19 LOT 18 LOT 8 LOT 9 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 10 LOT 11 LOT 12 LOT 75 LOT 74 LOT 73 LOT 72 LOT 70 LOT 63 LOT 69 LOT 68 LOT 67 LOT 66 LOT 65 LOT 64 LOT 55 LOT 60 LOT 59 LOT 58 LOT 57 LOT 56 LOT 54 LOT 47 LOT 53 LOT 52 LOT 51 LOT 50 LOT 49 LOT 48 LOT 78 32 33 JF 31 30 31A 31B 10 11 11B 12 13 14 15 16 16A 16B 17 17A 17B 19 18 20 21 43 41 40 37 36 35 34 31C 42 38 BMP #2 / BIORETENTION STORM DRAINAGE ESMT. STORM DRAINAGE ESMT. STORM DRAINAGE ESMT. STORM DRAINAGE ESMT. RIVANNA PL. (PRIVATE)RIVANNA PL.(PRIVATE)GAP RUN DR. (PRIVATE) BMP #1 / WET POND 3 BMP #3 / JELLYFISH LOT 16LOT 15 LOT 14 LOT 13 5 634632630636638640642605.5610 606 600600 602 604 608 634632630636638640642644646648650652654634636638640642644646648650652638640642644646636634632632636638640 612 614 610 616 620 626624622 612 614 610 616 618 612614616614616610612614612 614 6 1 2 614 62 0 62 6 62 8 630 6 2 4 622 618 616 6 1 2 6 1 8 6 1 6 61 4610 620 622 624 620622624618 616 626 628 626 612616614612 616 614 610610 612614610632630 628626624 622 620 618 616614616618620622624 626628630616618 620 6226 2 4 6 2 4 626 6 2 8 630 6 3 2 634634632630628626622620618616614632 630626624622618616614612 6 1 0 612612612624620628628612614616618620622612614616618620610608 599.95 616 61 8 6 2 0 6226246 2 6 6 2 8614616618620622624626 6286 1 6 6 1 8 6 2 0 62 2 6 2 4 626626626 6 2 8 6146146 1 4 6 1 4612 614614614612614612600.75600.75590592 594 596 598600 602 604 25 18 26 52 23 85 22 52 21 18 18 52 17 18 19 85 15 97 17 75 18 97 20 10 21 10 22 10 23 10 24 10 17 06 18 40 19 73 21 06 22 40 23 73 25 06 26 40 23 52 10 63 14 86 16 46 17 87 19 28 20 70 22 11 24 76 24 86 24 86 24 86 24 86 25 25 25 25 25 62 25 99 26 29 73 29 07 28 40 27 73 27 73 27 07 26 40 26 40 29 85 28 82 28 03 27 29 26 86 26 46 26 06 25 66 25 08 26 52 26 52 27 19 27 85 27 85 28 52 29 19 24 76 24 53 29 40 16 04 13 64 14 21 16 70 16 70 14 59 15 07 17 37 18 71 16 18 17 40 20 04 18 62 21 37 20 85 23 70 22 30 24 37 23 30 25 70 24 30 26 37 25 30 25 80 26 20 29 03 28 37 27 70 28 91 28 25 27 58 26 25 25 58 24 25 23 58 21 25 19 92 18 59 17 25 16 58 16 58 15 92 30 82 16 06 17 39 17 82 19 39 18 72 20 72 19 62 22 05 20 52 22 72 21 42 23 38 25 76 23 12 26 43 24 49 27 09 25 49 28 43 26 49 29 09 27 49 28 49 29 76 29 49 31 09 30 49 32 42 31 33 30 65 12 39 12 84 14 15 15 46 16 77 18 19 19 62 21 05 24 09 24 98 25 86 26 75 27 52 28 30 29 07 15 94 17 27 17 94 19 27 20 60 21 93 22 60 23 26 25 64 26 31 26 97 28 31 28 97 29 64 30 97 32 30 17 31 18 64 19 31 20 64 21 31 21 97 23 31 23 97 26 26 27 59 28 26 29 59 30 26 31 59 32 26 33 59 33 71 32 38 31 71 30 38 29 71 28 38 27 71 26 38 24 09 23 43 22 09 21 43 20 76 19 43 18 76 17 43 15 68 16 35 17 66 18 56 19 46 20 36 21 26 22 16 23 07 24 29 25 06 26 51 27 51 28 51 29 51 31 51 30 51 32 51 33 41 28 82 29 52 28 76 27 99 27 11 25 56 24 42 23 56 21 43 20 00 19 34 18 56 17 71 16 85 16 00 15 14 13 09 27 41 26 03 25 30 24 43 23 38 22 34 21 00 17 94 16 96 15 99 15 40 15 16 14 75 14 13 14 42 15 15 16 02 16 92 18 06 22 45 22 94 22 20 22 50 146411961464123214641257146412821464130714641327146413121464128714641253146412381397122313971208139711931331117412641129119710911188118811881194120012001200120012001200117211441111107810460953081711871452145214521452145214521452145214521452138513851385131912521185113312001133127612721073TO STR. #19 DA=0.06 AC. C=0.40 TO STR. #31B DA=0.25 AC. C=0.70 TO STR. #35 DA=0.13 AC. C=0.55 TO STR. #32 DA=0.12 AC. C=0.79 TO STR. #21 DA=3.07 AC. C=0.26 TO STR. #20 DA=0.18 AC. C=0.63 TO STR. #18 DA=0.23 AC. C=0.68 TO STR. #17B DA=6.51 AC. C=0.29 TO STR. #16 DA=0.30 AC. C=0.40 TO STR. #16A DA=0.25 AC. C=0.77 TO STR. #16B DA=0.68 AC. C=0.74 TO STR. #43 DA=0.55 AC. C=0.68 TO STR. #15 DA=0.28 AC. C=0.50 TO STR. #13 DA=0.54 AC. C=0.67 TO STR. #11B DA=1.09 AC. C=0.47 TO STR. #41 DA=0.21 AC. C=0.47 TO STR. #42 DA=0.61 AC. C=0.49 TO STR. #38 DA=0.14 AC. C=0.69 TO STR. #37 DA=0.20 AC. C=0.60 TO STR. #36 DA=0.78 AC. C=0.57 TO STR. #31C DA=0.50 AC. C=0.74 TO STR. #33 DA=0.25 AC. C=0.58 TO STR. #12 DA=0.30 AC. C=0.75 TO STR. #31A DA=0.04 AC. C=0.80 TO STR. #34 DA=0.19 AC. C=0.54 PS PS PS PS PS PS PS SSF SSF SSF SSF SSF SSF SSF SSF SSFSSFSSF SSF SSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSF SSF SSF SSF SSF SSF SSF SSF SSF SSF CFS CFS CFS CLASS A1 RIPRAP CLASS A1 RIPRAP CLASS A1 RIPRAP AND FLOW SPREADER SEE SHEET 25 11A CL A1 RIPRAP 16'L X 10'W X 18"D CL A1 RIPRAP 12'L X 10'W X 18"D NOTES: 1.FOR FILLS IN AREAS OF PROPOSED STRUCTURES, (ROADWAYS, RESIDENTIAL DWELLINGS, RETAINING WALL, ETC.), PLEASE SEE CURRENT GEOTECHNICAL REPORT FOR MINIMUM CONTROLLED FILL REQUIREMENTS. ALL CONTROLLED FILLS SHALL BE PLACED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT AND COORDINATED WITH THE DEVELOPER'S GEOTECHNICAL ENGINEER. 2.PERIMETER CONTROLS ARE TO BE COMPLETELY INSTALLED PRIOR TO STARTING CONSTRUCTION OF SEDIMENT TRAPS AND SEDIMENT BASINS. 3.DIVERSION DIKES ARE TO BE MAINTAINED DAILY AS THE AREA IS GRADED. 4.EXISTING BMP'S TO REMAIN PROTECTED FROM SEDIMENT AT ALL TIMES. 5.SLOPES 3:1 AND GREATER SHALL BE PROTECTED WITH SOIL STABILIZATION BLANKETS (EC-2). 6.REFER TO SHEET 50B FOR DITCH SECTIONS. 7.REFER TO SHEET 78 FOR OUTLET PROTECTION COMPUTATIONS. 8.THE RUNOFF REDUCTION COMPLIANCE FOREST/OPEN SPACE AREA IS NOT TO BE DISTURBED DURING CONSTRUCTION AND SHOULD BE FENCED OFF WHEN INSTALLING INITIAL EROSION AND SEDIMENT CONTROL MEASURES. 9.REFER TO SHEET 10A FOR SEDIMENT TRAP DETAILS AND COMPUTATIONS.151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV1" = 30' 10 05/15/2025 ZJ, KAS ---- 51 3924L FOR PHASE II EROSION AND SEDIMENT CONTROL ONLY !! NO. KEY SYMBOL DESCRIPTION EROSION/SEDIMENT CONTROL LEGEND COMPOST FILTER SOCKC-PCM-05 CFS SILT FENCEC-PCM-04 SUPER SILT FENCEC-PCM-04 SSF SF TEMPORARY DIVERSION DIKEC-ECM-04 DD SAFETY FENCEC-PCM-01 SAF CFS SF SSF ROCK CHECK DAMSC-SCM-07 TEMPORARY SLOPE DRAINC-ECM-12 CD TSD STORMWATER CONVEYANCE CHANNELC-ECM-09 SCC STORM DRAIN INLET PROTECTIONC-SCM-04 IP CULVERT INLET PROTECTIONC-SCM-05 CIP TEMPORARY SEDIMENT BASINC-SCM-12 SB OUTLET PROTECTIONC-ECM-15 OP ROCK FILTER OUTLETC-SCM-08 RFO TEMPORARY GRAVEL CONSTRUCTION ENTRANCEC-SCM-03 CE STABILIZATION BLANKETS AND MATTINGC-SSM-05 PSC-SSM-09 TEMPORARY SEEDINGTS PSC-SSM-10 PERMANENT SEEDINGPS C-SCM-10 DS DEWATERING STRUCTURE B/M LIMITS OF CLEARING & GRADINGLCG DRAINAGE DIVIDES CRITICAL SLOPE - CRITICAL SLOPE TO BE SEEDED, MULCHED AND TACKED WITHIN 14 DAYS AFTER START OF GRADING, OR SODDED AND PEGGED WITHIN 14 DAYS AFTER START SLOPE STABILITY ANALYSIS SHALL BE REQUIRED (TO BE PROVIDED BY CONTRACTOR) FOR ROAD FILL EMBANKMENTS GREATER THAN 10' PER VDOT REQUIREMENTS. CARRYING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. IS THE PARTY RESPONSIBLE FOR THE RESPONSIBLE LAND DISTURBER DATE: CERTIFICATION #: NAME: RESPONSIBLE LAND DISTURBER 603001530 SCALE: 1" = 30' MATCH LINE SEE SHEET #E&S PHASE II (2)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 02 07/31/2025 06Feb2026 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVMINIMUM CONSTRUCTION STANDARDS An erosion and sediment control program adopted with this plan must be consistent with the VSECH for 9VAC25-840-40 minimum standards: 1.Permanent or temporary soil stabilization shall be applied to denuded areas within seven days after final grade is reached on any portion of the site. Temporary soil stabilization shall be applied within seven days to denuded areas that may not be at final grade but will remain dormant for longer than 14 days. Permanent stabilization shall be applied to areas that are to be left dormant for more than one year. 2.During construction of the project, soil stock piles and borrow areas shall be stabilized or protected with sediment trapping measures. The applicant is responsible for the temporary protection and permanent stabilization of all soil stockpiles on site as well as borrow areas and soil intentionally transported from the project site. 3.A permanent vegetative cover shall be established on denuded areas not otherwise permanently stabilized. Permanent vegetation shall not be considered established until a ground cover is achieved that is uniform, mature enough to survive and will inhibit erosion. 4.Sediment basins and traps, perimeter dikes, sediment barriers and other measures intended to trap sediment shall be constructed as a first step in any land-disturbing activity and shall be made functional before upslope land disturbance takes place. 5.Stabilization measures shall be applied to earthen structures such as dams, dikes and diversions immediately after installation. 6.Sediment traps and sediment basins shall be designed and constructed based upon the total drainage area to be served by the trap or basin. a.The minimum storage capacity of a sediment trap shall be 134 cubic yards per acre of drainage area and the trap shall only control drainage areas less than three acres. b.Surface runoff from disturbed areas that is comprised of flow from drainage areas greater than or equal to three acres shall be controlled by a sediment basin. The minimum storage capacity of a sediment basin shall be 134 cubic yards per acre of drainage area. The outfall system shall, at a minimum, maintain the structural integrity of the basin during a 100-year storm of 24-hour duration. Runoff coefficients used in runoff calculations shall correspond to a bare earth condition or those conditions expected to exist while the sediment basin is utilized. 7.Cut and fill slopes shall be designed and constructed in a manner that will minimize erosion. Slopes that are found to be eroding excessively within one year of permanent stabilization shall be provided with additional slope stabilizing measures until the problem is corrected. 8.Concentrated runoff shall not flow down cut or fill slopes unless contained within an adequate temporary or permanent channel, flume or slope drain structure. 9.Whenever water seeps from a slope face, adequate drainage or other protection shall be provided. 10.All storm sewer inlets that are made operable during construction shall be protected so that sediment-laden water cannot enter the conveyance system without first being filtered or otherwise treated to remove sediment. 11.Before newly constructed stormwater conveyance channels or pipes are made operational, adequate outlet protection and any required temporary or permanent channel lining shall be installed in both the conveyance channel and receiving channel. 12.When work in a live watercourse is performed, precautions shall be taken to minimize encroachment, control sediment transport and stabilize the work area to the greatest extent possible during construction. Nonerodible material shall be used for the construction of causeways and cofferdams. Earthen fill may be used for these structures if armored by nonerodible cover materials. 13.When a live watercourse must be crossed by construction vehicles more than twice in any six-month period, a temporary vehicular stream crossing constructed of nonerodible material shall be provided. 14.All applicable federal, state and local requirements pertaining to working in or crossing live watercourses shall be met. 15.The bed and banks of a watercourse shall be stabilized immediately after work in the watercourse is completed. 16.Underground utility lines shall be installed in accordance with the following standards in addition to other applicable criteria: a.No more than 500 linear feet of trench may be opened at one time. b.Excavated material shall be placed on the uphill side of trenches. c.Effluent from dewatering operations shall be filtered or passed through an approved sediment trapping device, or both, and discharged in a manner that does not adversely affect flowing streams or off-site property. d.Material used for backfilling trenches shall be properly compacted in order to minimize erosion and promote stabilization. e.Restabilization shall be accomplished in accordance with this chapter. f.Applicable safety requirements shall be complied with. 17.Where construction vehicle access routes intersect paved or public roads, provisions shall be made to minimize the transport of sediment by vehicular tracking onto the paved surface. Where sediment is transported onto a paved or public road surface, the road surface shall be cleaned thoroughly at the end of each day. Sediment shall be removed from the roads by shoveling or sweeping and transported to a sediment control disposal area. Street washing shall be allowed only after sediment is removed in this manner. This provision shall apply to individual development lots as well as to larger land-disturbing activities. 18.All temporary erosion and sediment control measures shall be removed within 30 days after final site stabilization or after the temporary measures are no longer needed, unless otherwise authorized by the VESCP authority. Trapped sediment and the disturbed soil areas resulting from the disposition of temporary measures shall be permanently stabilized to prevent further erosion and sedimentation. 19.Properties and waterways downstream from development sites shall be protected from sediment deposition, erosion and damage due to increases in volume, velocity and peak flow rate of stormwater runoff for the stated frequency storm of 24-hour duration in accordance with the following standards and criteria. Stream restoration and relocation projects that incorporate natural channel design concepts are not man-made channels and shall be exempt from any flow rate capacity and velocity requirements for natural or man-made channels: a.Concentrated stormwater runoff leaving a development site shall be discharged directly into an adequate natural or man-made receiving channel, pipe or storm sewer system. For those sites where runoff is discharged into a pipe or pipe system, downstream stability analyses at the outfall of the pipe or pipe system shall be performed. b.Adequacy of all channels and pipes shall be verified in the following manner: (1)The applicant shall demonstrate that the total drainage area to the point of analysis within the channel is one hundred times greater than the contributing drainage area of the project in question; or (2)(a) Natural channels shall be analyzed by the use of a two-year storm to verify that stormwater will not overtop channel banks nor cause erosion of channel bed or banks. (b)All previously constructed man-made channels shall be analyzed by the use of a 10-year storm to verify that stormwater will not overtop its banks and by the use of a two-year storm to demonstrate that stormwater will not cause erosion of channel bed or banks; and (c)Pipes and storm sewer systems shall be analyzed by the use of a 10-year storm to verify that stormwater will be contained within the pipe or system. c.If existing natural receiving channels or previously constructed man-made channels or pipes are not adequate, the applicant shall: (1)Improve the channels to a condition where a 10-year storm will not overtop the banks and a two-year storm will not cause erosion to the channel, the bed, or the banks; or (2)Improve the pipe or pipe system to a condition where the 10-year storm is contained within the appurtenances; (3)Develop a site design that will not cause the pre-development peak runoff rate from a two-year storm to increase when runoff outfalls into a natural channel or will not cause the pre-development peak runoff rate from a 10-year storm to increase when runoff outfalls into a man-made channel; or (4)Provide a combination of channel improvement, stormwater detention or other measures which is satisfactory to the VESCP authority to prevent downstream erosion. d.The applicant shall provide evidence of permission to make the improvements. e.All hydrologic analyses shall be based on the existing watershed characteristics and the ultimate development condition of the subject project. f.If the applicant chooses an option that includes stormwater detention, he shall obtain approval from the VESCP of a plan for maintenance of the detention facilities. The plan shall set forth the maintenance requirements of the facility and the person responsible for performing the maintenance. g.Outfall from a detention facility shall be discharged to a receiving channel, and energy dissipators shall be placed at the outfall of all detention facilities as necessary to provide a stabilized transition from the facility to the receiving channel. h.All on-site channels must be verified to be adequate. i.Increased volumes of sheet flows that may cause erosion or sedimentation on adjacent property shall be diverted to a stable outlet, adequate channel, pipe or pipe system, or to a detention facility. j.In applying these stormwater management criteria, individual lots or parcels in a residential, commercial or industrial development shall not be considered to be separate development projects. Instead, the development, as a whole, shall be considered to be a single development project. Hydrologic parameters that reflect the ultimate development condition shall be used in all engineering calculations. k.All measures used to protect properties and waterways shall be employed in a manner which minimizes impacts on the physical, chemical and biological integrity of rivers, streams and other waters of the state. l.Any plan approved prior to July 1, 2014, that provides for stormwater management that addresses any flow rate capacity and velocity requirements for natural or man-made channels shall satisfy the flow rate capacity and velocity requirements for natural or man-made channels if the practices are designed to (i) detain the water quality volume and to release it over 48 hours; (ii) detain and release over a 24-hour period the expected rainfall resulting from the one year, 24-hour storm; and (iii) reduce the allowable peak flow rate resulting from the 1.5, 2, and 10-year, 24-hour storms to a level that is less than or equal to the peak flow rate from the site assuming it was in a good forested condition, achieved through multiplication of the forested peak flow rate by a reduction factor that is equal to the runoff volume from the site when it was in a good forested condition divided by the runoff volume from the site in its proposed condition, and shall be exempt from any flow rate capacity and velocity requirements for natural or man-made channels as defined in any regulations promulgated pursuant to § 62.1-44.15:54 or 62.1-44.15:65 of the Act. m.For plans approved on and after July 1, 2014, the flow rate capacity and velocity requirements of § 62.1-44.15:52 A of the Act and this subsection shall be satisfied by compliance with water quantity requirements in the Stormwater Management Act (§ 62.1-44.15:24 et seq. of the Code of Virginia) and attendant regulations, unless such land-disturbing activities are in accordance with 9VAC25-870-48 of the Virginia Stormwater Management Program (VSMP) Regulation or are exempt pursuant to subdivision C 7 of § 62.1-44.15:34 of the Act. n.Compliance with the water quantity minimum standards set out in 9VAC25-870-66 of the Virginia Stormwater Management Program (VSMP) Regulation shall be deemed to satisfy the requirements of this subdivision 19. EROSION AND SEDIMENT CONTROL NARRATIVE Description: The Project development will consist of the construction of Single Family townhomes with related utilities and road construction. The property, zoned RP, is located approximately 0.3 miles south of intersection of Senseny Road and Rossum Lane in Frederick County Virginia. This project will be the final planned phase of the overall Senseny Village project. This plan is for Phase I. Total site area for Phase 1&2 is 73.79 acres of which approximately 12.12 acres will be disturbed for construction. Date of construction: Construction may begin following plan approval and the submission and approval of all required Slope Stability Analyses. This project will take approximately eighteen (18) months to complete. Existing site conditions: The site is currently vacant consisting of woods and open fields. The site is divided by multiple ridges and swales which all drain south to tributaries of Opequon Creek. Typical slopes range between 4% and 60%. Adjacent areas: The site is bounded by a stream and vacant land to the south and by residential property to the north, east and west. Offsite areas: No offsite areas proposed to be disturbed with this plan. Soils: The existing soil conditions were obtained from the NRCS Soils Survey. Refer to the soils map this sheet. Critical areas: Delineated streams/wetlands, riparian buffers and steep slope areas, as shown on the plans, are designated as critical areas. Disturbance around all critical areas should be kept to a minimum and protected by the E&S control measures shown on the plan. The large fill slopes adjacent to the riparian buffers/streams are also considered critical. Fill should be permanently stabilized and seeded as construction commences. Diversions are to be utilized to protect slopes at the end of each working day. At no time are the slopes to be left in a state to receive concentrated runoff. The up-slope drainage areas should remain undisturbed until the fill slopes are stabilized to reduce the release of sediment into the streams/wetlands. Note:The streams/wetlands can not be disturbed without an USACE permit. Erosion And Sediment Control Measures: Unless otherwise indicated, all vegetative and structural erosion and sediment control measures shall be constructed and maintained according to the minimum standards and specifications of the Virginia Erosion and Sediment Control Handbook. Structural Measures: Phase I and 1A: During phase I and 1A clearing and grubbing should only be completed where necessary to install initial erosion and sediment controls as shown on the plans for each phase. Phase 1A provides for a temporary stream crossing while the box culverts are partially installed to establish the permanent crossing. The construction entrance, orange safety fence, silt fence and super silt fence should be installed first to protect and visibly locate the riparian buffers and streams. Next the storm sewer, temporary culvert and associated berm/diverision near the construction entrance shown on the phase I plans should be installed to bypass clean offsite water through the construction site and to protect the adjacent residential lots from erosion and sediment. Next the sediment basins should be installed and immediately stabilized. Once stabilized the diversions should be installed starting at the sediment basin and working up-slope of the drainage area directing disturbed areas to the sediment trapping facilities. Where critical fill slopes are encountered they are to be constructed and stabilized immediately during periods of dry weather. The drainage areas up-slope of these fill areas are to remain undisturbed until the embankments are completed and the diversion is constructed above the fill slope directing up-slope storm water to the sediment basins. After the fill slope is completed the remaining up slope diversion is to be completed until the next critical fill slope is encountered where the cycle is repeated. Only after all perimeter erosion and sediment controls are installed and the critical fill slopes and diversions are stabilized should clearing and grubbing operations associated with the mass grading of the site proceed. Install Safety Fence (3.01) as shown on the plans to prevent access to critical areas. Install Temporary Construction Entrance with Wash Rack (3.02) as shown on the plans to minimize sediment carried onto roadway. Install silt fence (3.05) and super silt fence as shown on the plans to intercept and detain small amounts of sediment from disturbed areas during construction in order to prevent sediment from leaving the site. Install storm drain inlet protection (3.07) as shown on plans to prevent sediment from entering storm drainage systems prior to permanent stabilization of the disturbed area. Culvert inlet protection (3.08) shall be located at culvert entrances as shown to prevent sediment from entering, accumulating in and being transferred by the culvert prior to permanent stabilization of the disturbed area. Install temporary diversion dikes (3.09) as shown on the plans to divert sediment-laden runoff to the sediment trapping structures. Install diversion (3.12) as shown on the plans to reduce the slope length and to intercept and divert stormwater runoff to stabilized outlets at non-erosive velocites. Install Temporary Sediment Basins (3.14) as shown on plans to detain sediment-laden runoff from disturbed areas in "wet" and "dry" storage long enough for the majority of the sediment to settle out. Note: Sediment Basins #1 & #2 will become a permanent stormwater facility upon completion of the project. Contractor is to install the permanent SWM structures associated with the pond during Phase I E&S measures. The structure must be modified in order to serve as temporary sediment basins. SWM basins shall not be converted from temporary sediment basins until their respective drainage areas are completed and fully stabilized. Install Stormwater Conveyance Channel (3.17) as shown to provide for the conveyance of concentrated surface runoff water to a receiving channel or system without damage from erosion. Outlet protection (3.18) shall be installed on all outlets as shown on the plan sheets. Install rock check dams (3.20) as shown on the plans to reduce the velocity of concentrated stormwater flows and to trap sediment generated from adjacent areas or the ditch itself. Temporary seeding (3.31) and/or permanent seeding (3.32) shall be placed on all critical slopes (3:1 or greater) and as needed to stabilize disturbed areas. Soil stabilization blankets & matting (3.36) shall be installed over steep 3:1 or greater cut and fills slope which have been brought to final grade and seeded to protect from rill and gully erosion. Phase II: Phase I controls shall remain into Phase II for the duration of the project or until drainage area is stabilized. ALL areas to be stabilized 100% prior to installation of bioretention basins. Fill slope surface shall be left in a roughened condition to reduce erosion, see Plate 3.29-4. Contractor shall redirect the concentrated flow away from the fill slope by installing diversion dike and divert the runoff to sediment traps or sediment basins. Temporary seeding (3.31) and/or permanent seeding (3.32) shall be placed on all critical slopes (3:1 or greater) and as needed to stabilize disturbed areas. Vegetative Measures: Permanent or temporary soil stabilization shall be applied to denuded areas within seven (7) days after final grade is reached on any portion of the site. Temporary soil stabilization shall be applied within seven (7) days to denuded areas that may not be at final grade but will remain dormant for longer than fourteen (14) days. Permanent soil stabilization shall be applied to all areas that are to be left dormant for more than one year. Topsoil that has been stockpiled shall be surrounded with silt fence and protected by mulch and/or temporary vegetation immediately after grading. All earth berms, diversions and sediment trap embankments are to be machine-compacted, seeded and mulched (hay mulch or straw) for temporary and/or permanent vegetative cover immediately after construction Erosion control mats shall be installed over steep (3:1) cut and fills slope which have been brought to final grade and seeded to protect from rill and gully erosion. Management Strategies: Construction shall be sequenced such that grading operations will begin and end as quickly as possible. The site superintendent shall be responsible for the installation and maintenance of all erosion and sediment control measures. Maintenance of these measures throughout the project is critical to the effectiveness of the program. After areas above controls have been stabilized, the controls shall be cleaned up and removed. Electric power, telephone, storm, sanitary, water & gas supply trenches are to be compacted, seeded and mulched within five (5) days after backfilling. No more than 500 feet are to be open at any one time. All cut and fill slopes are to be seeded and mulched within five (5) days of completion of grading. Drainage swales shall be stabilized with check dams until vegetation has been well established, at which time the check dams shall be removed. Devices listed above are considered minimum erosion and sediment controls. Additional control measures may be necessary due to contractor phasing or other unforeseen conditions. It is the contractor's responsibility to provide additional measures to those shown, as needed, in order to control erosion and contain sediment on site. All measures shall be installed according to the standards and specifications in the Virginia Erosion and Sediment Control Handbook. Stormwater Management: Increased runoff from this development will be controlled by the Project's stormwater management facilities. See sheets ## - ## and the accompanying SWM report. Maintenance Program: All control measures shall be inspected daily by the site superintendent or his representative and within 24 hours after any storm event greater than 0.5 inches of rain per 24-hour period. Any damaged structural measures are to be repaired by the end of the day. Seeded areas shall be checked regularly to ensure that a good stand of grass is maintained. All areas shall be fertilized and reseeded as needed until grass is established. Trapped sediment is to be removed as required to maintain 50% trap efficiency and disposed of by spreading on site. Inlet protection shall be checked regularly for sediment build-up. If the gravel outlet is clogged by sediment, it shall be removed and cleaned or replaced immediately. The contractor is responsible for keeping existing public roads in a clean, dust and mud free, condition at all times. Erosion and sediment control program: Phase I 1.Hold pre-construction meeting on site with inspector. 2.Install construction entrance. 3.Clearing and grubbing for sediment control devices only 4.Placement of sediment control devices. 5.Obtain inspector's approval prior to beginning grading operations. 6.Clear and grub main area of site protected by installed E&S controls. Phase II 7.Rough grade remainder of site. 8.Install drainage devices with sediment control. 9.Final grading. 10.Restoration and stabilization of disturbed areas. 11.Remove erosion and sediment control measures with the approval of the inspector. ALL areas to be stabilized 100% prior to installation of bioretention basins. Note: The Frederick County Public Works and Engineering Department retain the right to add and/or modify these erosion and sediment control measures during the construction process, within reason, to ensure adequate protection to the public and the environment. Seeding schedule (soil stabilization): 1.All permanent seeding shall be in accordance with section 3.31 & 3.32 of the VESCH. 2.Spread topsoil at a minimum depth of four (4) inches. 3.Incorporate pulverized agricultural limestone into the topsoil at a rate of 92 lbs. per 1,000 square feet (2 tons per acre). 4.Fertilize with 10-10-10 fertilizer at a rate of 23 lbs per 1,000 square feet (1,000 lbs per acre). 5.Seed all areas with a seed mix consisting of 67% Kentucky 31 Tall Fescue and 33% Red Top Clover. 6.Mulch all seeded areas with straw mulch applied at a rate of 3,500 lbs per acre anchored with cutback or emulsified asphalt applied at a rate of 200 gallons per acre. Dust control: 1.Temporary seeding shall be applied to all disturbed areas subject to little or no construction traffic. 2.All haul roads and other heavy traffic routes shall be sprinkled with water until the surface is wet and repeated as needed to control dust. VARIANCE REQUEST - SMARTFENCE & COMPOST FILTER SOCK: We are requesting the use of an alternative erosion and sediment control measures that is not listed in the Virginia Erosion and Sediment Control Handbook. 1.ACF Environmental - Smartfence: Smartfence is an perimeter erosion control device equivalent to super silt fence, see detail on sheet 12. 2.Filtrexx - Compost Filter Sock: Compost filter sock is equivalent to silt fence, see detail on sheet 12. This will allow for less disturbance since it can be installed on the surface and requires no excavation. N/A 11 05/15/2025 ZJ, KAS ---- 51 3924L RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIE&S NARRATIVERev. No.Date 02 07/31/2025 06Feb2026 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVN/A 12 05/15/2025 ZJ, KAS ---- 51 3924L 2" X 2" X 36" WOODEN STAKES PLACED 10' O.C. SECTION NTS PLAN NTS NOTES: 1. ALL MATERIAL TO MEET FILTREXX® SPECIFICATIONS. 2. FILTER MEDIA™ FILL TO MEET APPLICATION REQUIREMENTS. 3. COMPOST MATERIAL TO BE DISPERSED ON SITE, AS DETERMINED BY ENGINEER. 12" MIN FILTREXX® SEDIMENT CONTROL NTS FILTREXX® SOXX™ (12" TYPICAL) BLOWN/PLACED FILTER MEDIA™ AREA TO BE PROTECTEDWORK AREA WORK AREA AREA TO BE PROTECTED 2" X 2" X 36" WOODEN STAKES PLACED 10' O.C. FILTREXX® SOXX™ (12" TYPICAL) WATER FLOW RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIE&S DETAILSRev. No.Date 06Feb2026 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVN/A 13 05/15/2025 ZJ, KAS ---- 51 3924L RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIE&S DETAILS (2)Rev. No.Date 02 07/31/2025 06Feb2026 US HOME CORPORATION T.M. 65- A - 5 5US HOM E C O R P O R A T I O N 55.24 A C INST# 2 0 0 0 0 8 1 1 4 ZONE: R P 2812811,900 SF2,898 SF LOT 2LOT 1 2,898 SF LOT 8 2,898 SF LOT 9 2,898 SF LOT 161,900 SF LOT 3 1,900 SF LOT 4 1,900 SF LOT 5 1,900 SF LOT 6 1,900 SF LOT 7 1,900 SF LOT 10 1,900 SF LOT 11 1,900 SF LOT 12 1,900 SF LOT 13 1,900 SF LOT 14 1,900 SF LOT 15 BMP #1 / WET POND 3 BMP #3 / JELLYFISH RIVANNA PL.CG-65' SIDEWALK9.0' TYP. 49.0' 28.0'30'R50.0' 61.5' STORM DRAINAGE ESMT. 20' BRL CG-12C CG-115' SIDEWALKLEHIGH DR.(PUBLIC)LEHIGH DR.(PUBLIC)SEE DETAIL CG-12C 50.0' 27.0'CG-6CG-6CG-6CG-630'R 30 'R30'R30'R 30' R FREDERICK WATER 30' ESMT. 20' BRL 10' BRL10' BRL10' BRL10' BRL25' BRL25' BRL10+0011+0030+0031+0032+0033+0034+0034+90.74RETAINING WALL #2 (DESIGN BY OTHERS), SEE SHEET 465' SIDEWALK5' SIDEWALK5' SIDEWALK 5' SID E W A L K GUARDRAIL 95'30.5'95'30.5'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'30.5' 30.5'95'30.5' 30.5'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'30.5' 30.5' EXISTING WET POND 1 STORM DRAINAGE ESMT. STORM DRAINAGE ESMT. CG-9B GUARDRAIL EXISTING PUMP STATION & FW PARCEL ROWR O W ROW CROSSWALK CROSSWALK50' BRL50' BRLROW LIGHT POLE TYP. 20' TRAIL ESMT. TO BE DEDICATED TO FREDERICK COUNTY 15 MPH SPEED LIMIT SIGN (R2-1) LIGHT POLE TYP. STOP SIGN (R1-1) AND BAR TREE SAVE AREA TREE SAVE AREA TREE SAVE AREA151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV1 30' 14 05/15/2025 ZJ, KAS ---- 51 3924LGEOMETRY PLANRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE II30 0 30 60 SCALE: 1 30' 15 NOTES: 1. SEE SHEET 46 FOR WALL PROFILE MATCH LINE - SEE SHEET 15 Rev. No.Date 03 12/19/2025 06Feb2026 T.M. 65-A-186J WENCE, DANE MATTHEW & SARAH ANN INST. NO 150011940 ZONE: RA USE: RESIDENTIAL T.M. 65-A-186B WERDEBAUGH RONALD F. & MELANIE J. DB. 969 PG. 1563 ZONE: RA USE: RESIDENTIAL T.M. 65-A-190 DAVIS, WILMER R. & DONNA N. INST. NO 060024340 ZONE: RA USE: VACANT T.M. 65-A-72 EFG INVESTMENTS LLC DB. 955 PG. 724 ZONE: RS USE: VACANT T.M. 65-A-186M WERDEBAUGH QUINTON T & TORREY PRISCILA G INSTR. NO 220013241 ZONE: RA USE: RESIDENTIAL 1,900 SF2,898 SF 1,900 SF2,883 SF2,955 SF1,903 SF1,900 SF2,898 SF1,900 SF2,947 SF 2,898 SF 1,900 SF LOT 2LOT 1 LOT 29LOT 30LOT 78LOT 77LOT 76LOT 71LOT 61LOT 62 LOT 31 LOT 32 1,900 SF LOT 33 1,900 SF LOT 34 1,900 SF LOT 35 1,900 SF LOT 36 1,900 SF LOT 37 2,898 SF LOT 38 2,898 SF LOT 39 2,895 SF LOT 46 1,900 SF LOT 40 1,900 SF LOT 41 1,900 SF LOT 42 1,900 SF LOT 43 1,900 SF LOT 44 1,900 SF LOT 45 2,898 SF LOT 24 1,900 SF LOT 28 1,900 SF LOT 27 1,900 SF LOT 26 1,900 SF LOT 25 2,878 SF LOT 17 2,898 SF LOT 23 1,900 SF LOT 22 1,900 SF LOT 21 1,900 SF LOT 20 1,900 SF LOT 19 1,900 SF LOT 18 2,898 SF LOT 8 2,898 SF LOT 9 2,898 SF LOT 161,900 SF LOT 3 1,900 SF LOT 4 1,900 SF LOT 5 1,900 SF LOT 6 1,900 SF LOT 7 1,900 SF LOT 10 1,900 SF LOT 11 1,900 SF LOT 12 1,900 SF LOT 13 1,900 SF LOT 14 1,900 SF LOT 15 1,900 SFLOT 751,900 SFLOT 741,900 SFLOT 731,900 SFLOT 722,898 SFLOT 702,898 SFLOT 631,900 SFLOT 691,900 SFLOT 681,900 SFLOT 671,900 SFLOT 661,900 SFLOT 651,900 SFLOT 642,898 SF LOT 55 1,900 SF LOT 60 1,900 SF LOT 59 1,900 SF LOT 58 1,900 SF LOT 57 1,900 SF LOT 56 2,898 SF LOT 54 2,898 SF LOT 47 1,900 SF LOT 53 1,900 SF LOT 52 1,900 SF LOT 51 1,900 SF LOT 50 1,900 SF LOT 49 1,900 SF LOT 48 BMP #2 / BIORETENTION BMP #1 / WET POND 3 BMP #3 / JELLYFISH RIVANNA PL. (PRIVATE) 9.0' TYP. 49.0' 28.0' 48.0' 27.0' 66.0' 46.0' 66.0'46.0' 48.0' 27.0' 66.0' 46.0' 48.0' 27.0'30'R50.0' 61.5' 20.0' TYP. 9.0' TYP. 9.0' TYP. 20.0' TYP. ESMT. FREDERICK WATER 20' ESMT. 20' BRL CG-12C CG-11GAP RUN DR.(PRIVATE)GAP RUN DR. (PRIVATE)RIVANNA PL.(PRIVATE)SEE DETAIL SHEET 46 FOR DW APRONS(TYP) CG-12C CG-12C CG-12C CG-12C CG-12CCG-6CG-6CG-6R CG-6 CG-2CG-2 CG- 2 CG-6CG-6R CG-2CG-2CG-2 CG-6CG-6RCG-6CG-6CG-6CG-6 CG-6R 30'R30 'R30'R30'R 30' R 3 0 ' R 30'R 30' R 30'R 48.0'27.0' 9.0' TYP. 9.0' TYP. 9.0' TYP. 9.0' TYP. FREDERICK WATER 30' ESMT. FREDERICK WATER ESMT. (VAR.) STORM DRAINAGE ESMT. STORM DRAINAGE ESMT. STORM DRAINAGE ESMT.STORM DRAINAGE ESMT. STORM DRAINAGE ESMT. STORM DRAINAGE ESMT. 20' BRL 20' BRL20' BRL 20' BRL 20' BRL 20' BRL 20' BRL 50' BRL20' BRL20' BRL50' BRL10' BRL10' BRL10' BRL10' BRL10' BRL10' BRL10' BRL10' BRL10' BRL10' BRL10' BRL10' BRL10' BRL10' B R L 10' B R L 10' B R L 10' B R L 25' BRL25' BRL25' BRL 25' BRL 25' BRL 25' BRL 25' BRL 25' BRL 25' BRL25' BRL10+0011+0010+0011+0012+0013+0014+0015+00 16+00 17+00 18+00 19+00 10+ 0 0 11+00 12+00 13+00 14+00 15+0016+0017+0017+46.9834+90.74RETAINING WALL #2 (DESIGN BY OTHERS), SEE SHEET 46 RETAINING WALL #1 (DESIGN BY OTHERS), SEE SHEET 46 5' SIDEWALK 5' SID E W A L K 5' SIDEWALK5' SIDEWALK5' SIDEWALK 5' SIDEWALK5' SIDEWALK78'18.2'95'30.5'95'30.5'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'30.5' 30.5'95'30.5' 30.5'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'30.5' 30.5'95'30.5'99'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'30.5' 30.5'95'30.5' 30.5'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20' 30.5'94.2'30.5' 20' 20' 20'95'20' 20'95'20' 20'95'20' 20' 20' 20'95'20'30.5'95'30.5'95'30.5' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20'95'30.5'95'30.5' 20' 20'95'30.5'93'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'30.5' 30.5'95'30.5' 30.5'95'20' 20'95'20' 20'95'20' 20'95'20' 20'95'20' 20' 33.6' 95.6 '30.6'99' 95'20'20'95'20'20'95'20'20'95'20'20'95'20'20'95'20'30.5'95'30.5'95'30.5'95'30.5'20'95'20'20'95'20'20'95'20'20'95'20'20'95'20'20'95'20'30.5'95'30.5'30.8'95'95'95'30.5'20'31'2 7 . 3 '95'95'95'30.5' 30.5'95'30.6' TRASH RECEPTACLE AND PET WASTE STATION PARK AND PLAY TOT LOT(28'X20') TOT LOT ADA ACESS, SEE SHEET FOR 46 HC PARKING DETAIL 30' INACTIVE BUFFER 20' ACTIVE BUFFER30' INACTIVEBUFFER20' ACTIVEBUFFER15' INACTIVE BUFFER 10' ACTIVE BUFFER 40' ACTIVE BUFFER40' INACTIVE BUFFERPROFERRED ROUTE 37DEDICATION AREASTORM DRAINAGE ESMT. STORM DRAINAGE ESMT.10' BRL10' BRL10' BRLCG-9B CROSSWALK CROSSWALK SEE DETAIL SHEET 46 FOR DW APRONS(TYP)50' BRL50' BRL50' BRL 50' BRLCG-6 CG- 11 CG-6RCG-6R CG-11CG-6R CG-6CG-6RCROSSWALK CROSSWALK CG-6R CG TRANS. CG TRANS. LIGHT POLE TYP. STOP BAR AND SIGN (R1-1) LIGHT POLE TYP. LIGHT POLE TYP. LIGHT POLE TYP. 15 MPH SPEED LIMIT SIGN (R2-1) STOP BAR AND SIGN (R1-1) STOP BAR AND SIGN (R1-1) STOP BAR AND SIGN (R1-1) FREDERICK WATER ESMT. FREDERICK WATER 30' ESMT. FREDERICK WATER ESMT. (VAR.) FREDERICK WATER ESMT. (VAR.) FREDERICK WATER 30' ESMT. LIGHT POLE TYP. STOP SIGN (R1-1) AND BAR TREE SAVE AREA REC AREA 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV15 05/15/2025 ZJ, KAS ---- 51 3924LGEOMETRY PLAN (2)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE II1 30' 30 0 30 60 SCALE: 1 30' 15 NOTES: 1. SEE SHEET 46 FOR WALL PROFILE MATCH LINE - SEE SHEET 14 Rev. No.Date 03 12/19/2025 06Feb2026 US HOME CORPORATION T.M. 65- A - 5 5US HOM E C O R P O R A T I O N 55.24 A C INST# 2 0 0 0 0 8 1 1 4 ZONE: R P WMWMWMWMWMWMWM WMWMWMWMWMWMWMWM WMSSA 149A 149B 149E 149D149C 32 33 JF 31 30 31A 31B 10 11 36 3534 31C B C D E 5 4 3 2 1 BB 11A SSSSSSSWWWWWWWWWWLOT 2LOT 1 LOT 8 LOT 9 LOT 16LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 10 LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 BMP #1 / WET POND 3 BMP #3 / JELLYFISH RIVANNA PL.LEHIGH DR.(PUBLIC)LEHIGH DR.(PUBLIC)10+0011+0030+0031+0032+0033+0034+0034+90.74RETAINING WALL #2 (DESIGN BY OTHERS), SEE SHEET 46 EXISTING WET POND 1 XXXX25 18 26 5223852252 21 18185217181985 15 97 17 75 18 97 20 10 21 10 22 10 23 10 24 10 17 06 18 40 19 73 21 06 22 40 23 73 25 06 26 40 23 521063 14 86 16 46 17 87 19 28 20 70 22 11 24 76 24 86 24 86 24 86 24 86 25 25 25 25 25 62 25 99 26 45 29 732907 28 402773 27 732707 26 402640 29 85 28 822803272926862646260625662508 26 52 26 52 27 19 27 85 27 85 28 52 29 19 24 76 24 53 29 40 24 36 3.02.84.14.04.96.47.18.94.93.23.95.13.44.54.03.8SLAB= 627.40 SLAB= 626.06 SLAB= 624.73 SLAB= 623.40 SLAB= 622.06 SLAB= 620.73 SLAB= 619.40 SLAB= 618.06 SLAB= 627.40 SLAB= 627.40 SLAB= 628.07 SLAB= 628.73 SLAB= 628.73 SLAB= 629.40 SLAB= 630.07 SLAB= 630.73 26 01 SS 18 33 EX 25 55 SS 19 29 EX 23 86 SS 18 99 EX 24 81 SS 22 00 EX 3:1 4:1 3:1 3: 1 3:1 3:1 3:1 3:1 2:1 2:1 3:1558 556 556 634632630636638640642593.25594596598598.25599.75599.95605.5602604605.5600600 598 598.7 5 599.7 5 599.9 5 600600.75600.75599.75598.75596599.75599.75598.255985965946 1 2 6 1 8 6 1 6 6 1 4 6 1 0 620 622 624 620622624618616 626 628 626 61261661462261 2 6 1 0 60 8 60 6 60 4 60 2 606 602 604 608 610 599. 7 5 596 598 598. 2 5 599. 9 5 6025845865885905925945965986006 1 6 6186 2 0 6 2 2 6 2 4 626626626 6 2 8560562564566568570572574576578580582584586584582580578576574572570566564600600 600.75600.75568 582 584 604 588592594596598602600590566 602 600 598 596 594 592 590 588 586 580 578 576 574 572 570 558 558 56806 68 EP 06 53 EP 07 43 EP 07 57 EP 10 14 EP 10 13 EP 11 13 EP 11 05 EP 11 68 EP1173 EP 13 6103 28 72 00 59 LP 00 36 EP/LP 00 36 EP/LP 15 40 TOP 24 09 TOP 26 025800INV/SS5800SSGUARDRAIL GUARDRAIL SAFETY BERMS 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV16 05/15/2025 ZJ, KAS ---- 51 3924LGRADING PLANRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE II1=30 30 0 30 60 SCALE: 1 = 30 15 NOTES: 1. SEE SHEET 46 FOR WALL PROFILES MATCH LINE - SEE SHEET 17 Rev. No.Date 02 07/31/2025 06Feb2026 T.M. 65-A-186J WENCE, DANE MATTHEW & SARAH ANN INST. NO 150011940 ZONE: RA USE: RESIDENTIAL T.M. 65-A-186B WERDEBAUGH RONALD F. & MELANIE J. DB. 969 PG. 1563 ZONE: RA USE: RESIDENTIAL T.M. 65-A-190 DAVIS, WILMER R. & DONNA N. INST. NO 060024340 ZONE: RA USE: VACANT T.M. 65-A-72 EFG INVESTMENTS LLC DB. 955 PG. 724 ZONE: RS USE: VACANT T.M. 65-A-186M WERDEBAUGH QUINTON T & TORREY PRISCILA G INSTR. NO 220013241 ZONE: RA USE: RESIDENTIAL SSSSSSSWMWMWMWMWMWMWM WMWMWMWMWMWMWMWM WMWMWMWMWMWMWM WMWMWMWMWMWM WMWMWMWMWMWMWMWM WMWM WMWMWMWMWMWM WMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWM WMWMWMWMWMWMWMWM WMSSWM SSSSSSS32 33 JF 31 30 31A 31B 10 11 11B 12 13 14 15 16 16A 16B 17 17A 17B 19 18 20 21 43 41 40 37 36 3534 31C D E F G H K I J L 5 42 38 ARV WWWW11A SWWWWWWWWWW W W W W W W W W W SSSWMWMLOT 2LOT 1 LOT 29LOT 30LOT 78LOT 77LOT 76LOT 71LOT 61LOT 62 LOT 31 LOT 32 LOT 33 LOT 34 LOT 35 LOT 36 LOT 37 LOT 38 LOT 39 LOT 46 LOT 40 LOT 41 LOT 42 LOT 43 LOT 44 LOT 45 LOT 24LOT 28 LOT 27 LOT 26 LOT 25 LOT 17LOT 23 LOT 22 LOT 21 LOT 20 LOT 19 LOT 18 LOT 8 LOT 9 LOT 16LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 10 LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 LOT 75LOT 74LOT 73LOT 72LOT 70LOT 63LOT 69LOT 68LOT 67LOT 66LOT 65LOT 64LOT 55 LOT 60 LOT 59 LOT 58 LOT 57 LOT 56 LOT 54 LOT 47 LOT 53 LOT 52 LOT 51 LOT 50 LOT 49 LOT 48 BMP #2 / BIORETENTION BMP #1 / WET POND 3 BMP #3 / JELLYFISH RIVANNA PL. (PRIVATE) CG-12C GAP RUN DR.(PRIVATE)GAP RUN DR. (PRIVATE)RIVANNA PL.(PRIVATE)CG-12C CG-12C CG-12C CG-12C CG-6CG-6CG-6R CG-6 CG-2CG-2 CG- 2 CG-6CG-6R CG-2CG-2CG-2 CG-6CG-6RCG-6CG-6CG-6CG-6 CG-6R 10+0011+0010+0011+0012+0013+0014+0015+00 16+00 17+00 18+00 19+00 10+ 0 0 11+00 12+00 13+00 14+00 15+0016+0017+0017+46.9834+90.74RETAINING WALL #2 (DESIGN BY OTHERS), SEE SHEET 46 RETAINING WALL #1 (DESIGN BY OTHERS), SEE SHEET 46 5' SIDEWALK 5' SID E W A L K 5' SIDEWALK5' SIDEWALK5' SIDEWALK 5' SIDEWALK5' SIDEWALKCG-9B CG-6 CG- 11 CG-6RCG-6R CG-11CG-6R CG-6CG-6RCG-6R CG TRANS. CG TRANS.WWWWWWWW 1 . 0%0.58% 2.0 % 2 . 0%!2%2.5%2.2%2.3%3.0% 3.8%4.2%11.5%10.0%10.0%6.3%4.0%5.0%5.0%4.0%10.0%9.0%7.0%25 18 26 5223852252 21 18185217181985 15 97 17 75 18 97 20 10 21 10 22 10 23 10 24 10 17 06 18 40 19 73 21 06 22 40 23 73 25 06 26 40 23 521063 14 86 16 46 17 87 19 28 20 70 22 11 24 76 24 86 24 86 24 86 24 86 25 25 25 25 25 62 25 99 26 45 29 732907 28 402773 27 732707 26 402640 29 85 28 822803272926862646260625662508 26 52 26 52 27 19 27 85 27 85 28 52 29 19 24 76 24 53 29 40 24 36 16 04 13 64 14 21 16 70 16 70 14 59 15 07 17 37 18 71 16 18 17 40 20 04 18 62 21 37 20 85 23 70 22 30 24 37 23 30 25 70 24 30 26 37 25 30 25 80 26 20 29 032837 27 70 28 912825 27 582625 25 582425 23 5821251992 18 591725 16 581658 15 92 30 82 16 06 17 39 17 82 19 39 18 72 20 72 19 62 22 05 20 52 22 72 21 42 23 38 25 76 23 12 26 43 24 49 27 09 25 49 28 43 26 49 29 09 27 49 28 49 29 76 29 49 31 09 30 49 32 42 31 33 30 65 12 39 12 84 14 15 15 46 16 77 18 19 19 62 21 05 24 09 24 98 25 86 26 75 27 52 28 30 29 07 15 94 17 27 17 94 19 27 20 60 21 93 22 60 23 26 25 64 26 31 26 97 28 31 28 97 29 64 30 97 32 30 17 31 18 64 19 31 20 64 21 31 21 97 23 31 23 97 26 26 27 59 28 26 29 59 30 26 31 59 32 26 33 59 33 713238 31 713038 29 712838 27 712638 24 092343 22 092143 20 761943 18 761743 15 68 16 35 17 66 18 56 19 46 20 36 21 26 22 16 23 07 24 29 25 06 26 51 27 51 28 51 29 51 31 51 30 51 32 51 33 41 28 82 29 52 28 76 27 99 27 1125562442 23 562143 20 00 19 341856 17 71168516001514 13 09 27 412603253024432338 22 3421001794169615991540151614751413 14 42 15 15 16 02 16 92 18 06 21 61 22 39 22 20 22 50 14641196146412321464125714641282146413071464132714641312146412871464125314641238139712231397120813971193133111741264112911971091118811881188119412001200120012001200120011721144111110781046095308171187145214521452145214521452145214521452145213851385138513191252118511331200113312761272107328 41 HP3.0%2.8%4.1%4.0%4.9%6.4%7.1%8.9%4.9%3.2%3.9%5.1%3.4%4.5%4.0%3.8%8.5%9.4%7.4%8.6%8.9%10.0%9.7%9.8%7.7%8.3%7.7%8.3%9.5%9.8%3.7%4.1%3.0%4.8%3.7%3.1%4.4%3.8%4.6%4.5%3.0%4.4%3.0%4.4%3.0%4.4%3.0%5.1%3.9%5.8%6.9%9.0%7.6%7.3%9.1%7.2%5.5%7.2%5.5%4.7%5.5%7.1%9.9 % 8.0 % 7.7 % 6.3 % 5.8 % 4.7 % 5.6 % 6.1 % 7.8 % 7.8 % 6.5 % 6.5 % 7.6 % 5.4 % 5.0 % 3.4 % SLAB= 617.58SLAB=612.85SLAB=613.52SLAB=614.19SLAB=615.52SLAB= 618.27SLAB= 616.94 SLAB= 618.31 SLAB= 619.64 SLAB= 620.31 SLAB= 621.64 SLAB= 622.31 SLAB= 622.97 SLAB= 624.31 SLAB= 624.97 SLAB= 627.26 SLAB= 634.59SLAB= 628.59 SLAB= 629.26 SLAB= 630.59 SLAB= 631.26 SLAB= 632.59 SLAB= 633.26 SLAB= 622.25 SLAB= 617.58 SLAB= 618.25 SLAB= 619.59 SLAB= 620.92 SLAB= 629.91 SLAB= 624.58 SLAB= 625.25 SLAB= 626.58 SLAB= 627.25 SLAB= 628.58 SLAB= 629.25 SLAB=614.85SLAB=614.85SLAB=614.85SLAB=615.52SLAB=615.52SLAB=615.52SLAB=615.52SLAB=615.52SLAB=615.52SLAB=615.52SLAB=615.52SLAB=615.52SLAB= 624.26SLAB= 618.94 SLAB= 620.27 SLAB= 621.60 SLAB= 622.93 SLAB= 623.60 SLAB= 626.64 SLAB= 633.30SLAB= 627.31 SLAB= 627.97 SLAB= 629.31 SLAB= 629.97 SLAB= 630.64 SLAB= 631.97 SLAB= 627.40 SLAB= 626.06 SLAB= 624.73 SLAB= 623.40 SLAB= 622.06 SLAB= 620.73 SLAB= 619.40 SLAB= 618.06 SLAB= 627.40 SLAB= 627.40 SLAB= 628.07 SLAB= 628.73 SLAB= 628.73 SLAB= 629.40 SLAB= 630.07 SLAB= 630.73 SLAB= 616.92 3.2% 4.8% 1.9%1.4%0.0%1.5%2.0% 26 93 CL 27 57 CL 28 51 CL 27 28 EP 28 51 EP2764 SS 27 93 EP2758 EP 28 21 SW 28 26 SW 28 07 SW 28 15 SW 28 51 EP 28 25 SW3.0%0.6%2.0%2.0%1.0% 28 07 SS 28 85 SS2864 SS 31 80 HP 26 01 SS 18 33 EX 25 55 SS 19 29 EX 23 86 SS 18 99 EX 24 81 SS 22 00 EX 3:1 4:1 4:1 3:1 2: 1 3:1 3:1 2:1 10 %3:13:13:13:13:13:13:14:13:12:1 4:1 4:1 11 84 OLR3:1634632630636638640642593.25594596598598.25599.75599.95605.5602604605.5610 606 600600 602 604 608 598 598.7 5 599.7 5 599.9 5 600600.75600.75599.75598.75596599.75599.75598.25598596594634632630636638640642644646648650652654634636638640642644646648650652638640642644646636634632632636638640 612 614 610 616 620 626 624 622 61 2 61 4 61 0 61 6 61 8 612614616614616610612614612 614 6 1 2 61 4 6 2 0 62 6 6 2 8 63 0624622 6 1 8 616 6 1 2 6 1 8 6 1 6 6 1 4 6 1 0 620 622 624 620622624618616 626 628 626 612616614612 616 614 610610 612614610632630628 626624 622620618616 614616618620622624 626628 6306166 1 8 62 0 62262462462 6 628630632634634632630628626622620618616614632 63062662462261861661461 2 6 1 0 612612 61262462062862861261461661862062261261461661862061060 8 606 602 604 608 610 599. 7 5 596 598 598. 2 5 599. 9 5 616 6 1 8 6 2 0 6226246 2 6 62 8614616618620622624626 6286 1 6 6186 2 0 6 2 2 6 2 4 626626626 6 2 8 6146146 1 4 6 1 4612 614614614612614612600600600.75600.75604 602 600 598 596 06 68 EP 07 43 EP 07 57 EP 10 14 EP 10 13 EP 11 13 EP 11 05 EP 11 68 EP1173 EP 13 61 EP1203 EP 12 16 EP 11 15 EP 11 16 EP 12 21 EP 12 55 EP 14 29 EP 14 09 EP 12 58 EP 11 97 EP 11 12 EP 11 30 EP 11 30 EP 11 53 EP 31 17 EP 31 59 EP 34 41 EP 33 87 EP 33 68 EP 31 45 EP 31 15 EP 27 01 EP 26 55 EP 25 42 EP 27 14 EP 29 18 EP 28 95 EP/HP 28 72 EP 13 03 HP 10 50 LP 10 73 EP/LP 34 22 HP 34 45 EP/HP 12 80 EP/HP 10 27 EP/LP 33 99 HP 12 40 EP 11 46 EP 11 42 EP 12 27 EP 11 79 EP 10 78 EP 10 77 EP 11 74 EP 31 37 EP 33 99 EP 07 00 INV 07 25 INV 07 90 EX 08 70 EX 1038SS1198OLR1011TOP09 89 TOP 1175SS1095SS1015SS0895SS0835TOP0866SS15 40 TOP 1051TOP0829TOP24 09 TOP 14 84 TOP1257 TOP 22 80 24 101414 20 87 26 02 23 78 3:1 3:1 4:14:1OVERLAND RELIEF (OR2) OVERLAND RELIEF (OR1-2) OVERLAND RELIEF (OR1-1)151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV17 05/15/2025 ZJ, KAS ---- 51 3924LGRADING PLAN (2)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE II1=30' 30 0 30 60 SCALE: 1 = 30' 15 NOTES: 1. SEE SHEET 46 FOR WALL PROFILE MATCH LINE - SEE SHEET 16 Rev. No.Date 02 07/31/2025 OLR1-2 NTS 100 YEAR OVERLAND RELIEF DETAILS Drainage Area: 10.04 ac Runoff Coef.: 0.29 I100: 9.28 Q100: 27.24 cfs D100: 0.86 ft Elev100: 612.84 ft0.04% SI D E SL O P E 50.00% SIDE SLOPE D100 612.00 ft OLR1-1 NTS Drainage Area: 10.04 ac Runoff Coef.: 0.29 I100: 9.28 Q100: 27.24 cfs D100: 0.21 ft Elev100: 612.84 ft D100 612.75 ft OLR2 NTS Drainage Area: 1.03 ac Runoff Coef.: 0.47 I100: 9.28 Q100: 4.79 cfs D100: 0.25 ft Elev100: 612.09 ft1.90% SIDE SLOPE 1. 6 5% S I D E S L O P E D100 611.84 ft 611.98 ft 614.00 ft 613.03 ft 612.63 ft 614.31 ft RIVANNA PLACE 06Feb2026 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV17A 05/15/2025 ZJ, KAS ---- 51 3924LGER SETTLEMENT PLATES, REINFORCED SLOPES, & PAVEMENT DETAILSRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIAS SHOWN Rev. No.Date 04 02/06/2026 Refer to the Geotechnical Engineer Report for methods, materials and details for construction of all earthwork activities. 06Feb2026 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV17B 05/15/2025 ZJ, KAS ---- 51 3924LGER SETTLEMENT PLATES, REINFORCED SLOPES, & PAVEMENT DETAILS(2)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIAS SHOWN Rev. No.Date 04 02/06/2026 Refer to the Geotechnical Engineer Report for methods, materials and details for construction of all earthwork activities. 06Feb2026 US HOME CORPORATION T.M. 65- A - 5 5US HOM E C O R P O R A T I O N 55.24 A C INST# 2 0 0 0 0 8 1 1 4 ZONE: R P WMWMWMWMWMWMWM WMWMWMWMWMWMWMWM WMSSA B C D E BB SSSSSSSWWWWWWWWWW1,900 SF2,898 SF LOT 2LOT 1 2,898 SF LOT 8 2,898 SF LOT 9 2,898 SF LOT 161,900 SF LOT 3 1,900 SF LOT 4 1,900 SF LOT 5 1,900 SF LOT 6 1,900 SF LOT 7 1,900 SF LOT 10 1,900 SF LOT 11 1,900 SF LOT 12 1,900 SF LOT 13 1,900 SF LOT 14 1,900 SF LOT 15 RIVANNA PL. STORM DRAINAGE ESMT. 20' BRL SAN LAT (TYP)LEHIGH DR.(PUBLIC)LEHIGH DR.(PUBLIC)20' BRL 10' BRL10' BRL10' BRL10' BRL25' BRL25' BRL RETAINING WALL #2 (DESIGN BY OTHERS), SEE SHEET 46 STORM DRAINAGE ESMT. STORM DRAINAGE ESMT.50' BRL50' BRL149A 149B 149E 149D149C 32 33 JF 31 30 31A 31B 10 11 36 3534 31C 5 4 3 2 1 11A 30+008" W/L- E SEE SHEETS 30 & 31 FOR BOX CULVERT DETAILS 12" DIP W/L 12" DIP W/L 12" DIP W/L CONTRACTOR SHALL TIE-IN TO EX. W/L 6" REDUCER, 1-6" GV, FH ASSY 45° BEND 8 5 ' - 1 5 " A D S N - 1 2111' - 15" ADS N-12131' - 15" ADS N-12 88' - 1 5 " A D S N - 1 2 59' - 18" AD S N - 1 2 97' - 18" ADS N-1215' - 24"ADS N-12 5 3 ' - 1 2 " ADS N - 1 2 19' - 1 5 " AD S N - 1 2 92' - 30" ADS N-1212' - 30 "ADS N -12 1 5 ' - 1 2 " A D S N - 1 299' - 24" RCP V41' - 24" ADS N-127 0 ' - 2 4 " A D S N - 1 225' - 30"ADS N-12DI-1 DI-1 DI-3B-6' DI-3B-6' DI-3B-8' DI-3B-12' DI-3B-8' DI-3B-4' 32' - 15" ADS N-12 30' - 1 5 " AD S N - 1 2 JELLYFISH MH-1 EW-1 EW-1 MH-1 NYP-18" 60" RISER MH-1 MH-1 MH-1 EW-1 26' - 15"ADS N-1280' - 15" ADS N-1240' - 15" ADS N-12EX. DI-2B-6' DI-3B-6' DI-3C-6' DI-3C-6' DI-3B-6' DI-3B-6' 31' - 15" ADS N-12 31' - 15" ADS N-12 11.25° BEND 22.5° BEND 22.5° BEND FREDERICK WATER ESMT. (VAR.)10+0011+0012+0013+0014+0015+008" DIPCL 1 RIP RAP TO BE INSTALLED PER DETAILS ON SHEET 30 CL 1 RIP RAP UD-4 (TYP) UD-4 (TYP) UD-4 (TYP) 20' TRAIL ESMT. TO BE DEDICATED TO FREDERICK COUNTY 8"x12" REDUCER CL A1 RIPRAP 16'L X 10'W X 18"D CL A1 RIPRAP 16'L X 10'W X 18"D CL A1 RIPRAP 12'L X 10'W X 18"D UD-4 CONNECTION TO DI (TYP) UD-4 CONNECTION TO DI (TYP) UD-4 CONNECTION TO DI (TYP) UD-4 CONNECTION TO DI (TYP) CD-2 (TIE TO STR 149B & 149E) CL 1 RIP RAP TO BE INSTALLED PER DETAILS ON SHEET 30 FREDERICK WATER 30' ESMT.151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV18 05/15/2025 ZJ, KAS ---- 51 3924LUTILITY PLANRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE II1" 30' 30 0 30 60 SCALE: 1" 30' 15 MATCH LINE - SEE SHEET 19 Rev. No.Date 04 02/06/2026 NOTES: 1.VALVES, MANHOLES, ARV'S AND OTHER FREDERICK WATER SURFACE FEATURES SHALL NOT BE PLACED IN CURB AND GUTTER, NOR SLOPED PORTIONS OF HANDICAPPED RAMPS. CONTRACTOR SHALL COORDINATE LOCATIONS WITH THE FREDERICK WATER INSPECTOR. 2.IRRIGATION LINES AND DEVICES, LIGHT POLES, TRANSFORMERS, JUNCTION BOXES, PEDESTALS, OTHER OBSTACLES AND ALL DRY UTILITIES SHALL NOT BE PLACED ON FREDERICK WATER EASEMENTS. PERPENDICULAR IRRIGATION LINES, AND DRY UTILITY CROSSINGS ARE PERMITTED WITH 18" MINIMUM VERTICAL SEPARATION. 3.RETAINING WALLS AND THEIR TIE BACKS SUCH AS GEO GRID OR OTHER SUPPORTS SHALL NOT BE PLACED IN FREDERICK WATER EASEMENTS. 4.CONTRACTOR SHALL PROVIDE ONE KENNEDY I HYDRANT OR MUELLER SUPER CENTURION WITH HYDRO-GUARD FOR REMOTE PRESSURE AND TEMPERATURE MONITORING. THE DEVELOPER OR HIS/HER AGENT SHALL PROCURE A TWO-YEAR MONITORING CONTRACT FOR THE MONITORING SERVICE AND TELEMETRY AND PROVIDE ACCESS TO FREDERICK WATER ONCE THE SUBSCRIPTION IS ACTIVE. THE FREDERICK WATER INSPECTOR SHALL CHOOSE WHICH OF THE REQUIRED HYDRANTS SHALL BE A KENNEDY I HYDRANT OR MUELLER SUPER CENTURION EACH RESIDENTIAL SITE PLAN. 06Feb2026 T.M. 65-A-186J WENCE, DANE MATTHEW & SARAH ANN INST. NO 150011940 ZONE: RA USE: RESIDENTIAL T.M. 65-A-186B WERDEBAUGH RONALD F. & MELANIE J. DB. 969 PG. 1563 ZONE: RA USE: RESIDENTIAL T.M. 65-A-190 DAVIS, WILMER R. & DONNA N. INST. NO 060024340 ZONE: RA USE: VACANT T.M. 65-A-72 EFG INVESTMENTS LLC DB. 955 PG. 724 ZONE: RS USE: VACANT T.M. 65-A-186M WERDEBAUGH QUINTON T & TORREY PRISCILA G INSTR. NO 220013241 ZONE: RA USE: RESIDENTIAL SSSSSSSWMWMWMWMWMWMWM WMWMWMWMWMWMWMWM WMWMWMWMWMWMWM WMWMWMWMWMWM WMWMWMWMWMWMWMWM WMWM WMWMWMWMWMWM WMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWM WMWMWMWMWMWMWMWM WMSSWM SSSSSSSD E F G H K I J L ARV WWWWSWWWWWWWWWW W W W W W W W W W SSSWMWM1,900 SF2,898 SF 1,900 SF2,883 SF2,955 SF1,903 SF1,900 SF2,898 SF1,900 SF2,947 SF 2,898 SF 1,900 SF LOT 2LOT 1 LOT 29LOT 30LOT 78LOT 77LOT 76LOT 71LOT 61LOT 62 LOT 31 LOT 32 1,900 SF LOT 33 1,900 SF LOT 34 1,900 SF LOT 35 1,900 SF LOT 36 1,900 SF LOT 37 2,898 SF LOT 38 2,898 SF LOT 39 2,895 SF LOT 46 1,900 SF LOT 40 1,900 SF LOT 41 1,900 SF LOT 42 1,900 SF LOT 43 1,900 SF LOT 44 1,900 SF LOT 45 2,898 SF LOT 24 1,900 SF LOT 28 1,900 SF LOT 27 1,900 SF LOT 26 1,900 SF LOT 25 2,878 SF LOT 17 2,898 SF LOT 23 1,900 SF LOT 22 1,900 SF LOT 21 1,900 SF LOT 20 1,900 SF LOT 19 1,900 SF LOT 18 2,898 SF LOT 8 2,898 SF LOT 9 2,898 SF LOT 161,900 SF LOT 3 1,900 SF LOT 4 1,900 SF LOT 5 1,900 SF LOT 6 1,900 SF LOT 7 1,900 SF LOT 10 1,900 SF LOT 11 1,900 SF LOT 12 1,900 SF LOT 13 1,900 SF LOT 14 1,900 SF LOT 15 1,900 SFLOT 751,900 SFLOT 741,900 SFLOT 731,900 SFLOT 722,898 SFLOT 702,898 SFLOT 631,900 SFLOT 691,900 SFLOT 681,900 SFLOT 671,900 SFLOT 661,900 SFLOT 651,900 SFLOT 642,898 SF LOT 55 1,900 SF LOT 60 1,900 SF LOT 59 1,900 SF LOT 58 1,900 SF LOT 57 1,900 SF LOT 56 2,898 SF LOT 54 2,898 SF LOT 47 1,900 SF LOT 53 1,900 SF LOT 52 1,900 SF LOT 51 1,900 SF LOT 50 1,900 SF LOT 49 1,900 SF LOT 48 RIVANNA PL. (PRIVATE) ESMT. SAN LAT (TYP) SAN LAT (TYP) **WM (TYP) SAN LAT (TYP)**WM (TYP) **WM (TYP)GAP RUN DR.(PRIVATE)GAP RUN DR. (PRIVATE)RIVANNA PL.(PRIVATE)STORM DRAINAGE ESMT. STORM DRAINAGE ESMT. STORM DRAINAGE ESMT.STORM DRAINAGE ESMT. STORM DRAINAGE ESMT. STORM DRAINAGE ESMT. RETAINING WALL #2 (DESIGN BY OTHERS), SEE SHEET 46 RETAINING WALL #1 (DESIGN BY OTHERS), SEE SHEET 46 TRASH RECEPTACLE AND PET WASTE STATION PARK AND PLAY TOT LOT(28'X20') TOT LOT ADA ACESS, SEE SHEET FOR 46 HC PARKING DETAIL STORM DRAINAGE ESMT. STORM DRAINAGE ESMT.WWWWWWWW 32 33 JF 31 30 31A 31B 10 11 11B 12 13 14 15 16 16A 16B 17 17A17B 19 18 20 21 43 41 40 37 36 3534 31C 5 42 38 11A 8" DIP W/L 8" DIP W/L 8" DIP W/L 8" DIP W/L 8" DIP W/L 8" DIP W/L 8" DIP W/L 8" DIP W/L 12" DIP W/L 12"x8" TEE, 1-12" GV, 2-8" GV 8"X6" TEE, 1-6" GV, FH ASSY 8" TEE, 3 - 8" GV 6" REDUCER, 1-6" GV, FH ASSY 8"X6" TEE, 1-6" GV, FH ASSY 45° BEND 22.5° BEND 8"X6" TEE, 1 - 6" G.V., FH ASSY 22.5° BEND 8" TEE, 3 - 8" G.V. 8"X6" TEE, 1-6" GV, FH ASSY 6" REDUCER, 1-6" GV, FH ASSY 45° BEND 8"X6" TEE, 2 - 6" GV, FH ASSY AIR RELEASE VALVE 94' - 12" ADS N-128 5 ' - 1 5 " A D S N - 1 2111' - 15" ADS N-12131' - 15" ADS N-12 88' - 1 5 " A D S N - 1 2 59' - 18" AD S N - 1 2 97' - 18" ADS N-1215' - 24"ADS N-12 5 3 ' - 1 2 " ADS N - 1 2 19' - 1 5 " AD S N - 1 2 71' - 1 2 " A D S N - 1 2 111' - 1 5 " A D S N - 1 2174' - 30" ADS N-1229' - 30" A D S N - 1 2 95' - 3 0 " A D S N - 1 2 15' - 30"ADS N-1292' - 30" ADS N-1212' - 30 "ADS N -12125' - 12" ADS N-1270' - 12" ADS N-1214' - 1 5 " AD S N - 1 2 74' - 2 4 " A D S N - 1 2 25' - 24 " ADS N-1 2 23' - 2 4 " ADS N - 1 2 110' - 2 4 " A D S N - 1 2187' - 24" ADS N-128' - 2 4 " ADS N - 1 2 86' - 12" ADS N-121 5 ' - 1 2 " A D S N - 1 299' - 24" RCP VDI-1 DI-1 DI-3B-6' DI-3B-6' DI-3B-8' DI-3B-6' DI-3C-6' DI-3B-8' DI-1 DI-1 EW-1 DI-3B-12' DI-3B-8' DI-3B-4' 32' - 15" ADS N-12 30' - 1 5 " AD S N - 1 2 JELLYFISH MH-1 EW-1 EW-1 MH-1 NYP-18" NYP-24" DI-3C-6' DI-3B-6' MH-1 DI-1 DI-1 DI-7 DI-7EW-1 32' - 24"ADS N-12DI-3A DI-3A DI-3A EW-1 DI-3B-6' DI-3B-12' 60" RISER FREDERICK WATER ESMT. (VAR.) FREDERICK WATER ESMT. (VAR.) FREDERICK WATER ESMT. (VAR.) 10+ 0 0 14+0015+0010+0011+0012+0013+0014+0015+00 16+00 17+00 18+00 19+008" DIPCL 1 RIP RAP UD-4 (TYP) 8"X8" TEE, 3-8" GV 1-8" GV, 8" STUB W/FLUSHING ASSY 8" DIP W/L10+0011+00 12+00 13+00 14+00 15+ 0 0 16+0017+00CL A1 RIPRAP 16'L X 10'W X 18"D CL A1 RIPRAP 12'L X 10'W X 18"D CONNECTION TO DI (TYP) CD-2 (TIE TO STR 12) CLASS A1 RIPRAP AND FLOW SPREADER SEE SHEET 25 FREDERICK WATER 30' ESMT. FREDERICK WATER ESMT. (VAR.)FREDERICK WATER 30' ESMT. FREDERICK WATER 20' ESMT.151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV19 05/15/2025 ZJ, KAS ---- 51 3924LUTILITY PLAN (2)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE II1" 30' 30 0 30 60 SCALE: 1" 30' 15 MATCH LINE - SEE SHEET 18 NOTES: 1.VALVES, MANHOLES, ARV'S AND OTHER FREDERICK WATER SURFACE FEATURES SHALL NOT BE PLACED IN CURB AND GUTTER, NOR SLOPED PORTIONS OF HANDICAPPED RAMPS. CONTRACTOR SHALL COORDINATE LOCATIONS WITH THE FREDERICK WATER INSPECTOR. 2.IRRIGATION LINES AND DEVICES, LIGHT POLES, TRANSFORMERS, JUNCTION BOXES, PEDESTALS, OTHER OBSTACLES AND ALL DRY UTILITIES SHALL NOT BE PLACED ON FREDERICK WATER EASEMENTS. PERPENDICULAR IRRIGATION LINES, AND DRY UTILITY CROSSINGS ARE PERMITTED WITH 18" MINIMUM VERTICAL SEPARATION. 3.RETAINING WALLS AND THEIR TIE BACKS SUCH AS GEO GRID OR OTHER SUPPORTS SHALL NOT BE PLACED IN FREDERICK WATER EASEMENTS. 4.CONTRACTOR SHALL PROVIDE ONE KENNEDY I HYDRANT OR MUELLER SUPER CENTURION WITH HYDRO-GUARD FOR REMOTE PRESSURE AND TEMPERATURE MONITORING. THE DEVELOPER OR HIS/HER AGENT SHALL PROCURE A TWO-YEAR MONITORING CONTRACT FOR THE MONITORING SERVICE AND TELEMETRY AND PROVIDE ACCESS TO FREDERICK WATER ONCE THE SUBSCRIPTION IS ACTIVE. THE FREDERICK WATER INSPECTOR SHALL CHOOSE WHICH OF THE REQUIRED HYDRANTS SHALL BE A KENNEDY I HYDRANT OR MUELLER SUPER CENTURION EACH RESIDENTIAL SITE PLAN. Rev. No.Date 04 02/06/2026 06Feb2026 TC FLOW PATH TC FLOW PATH TC FLOW PATH TC FLOW PATH TC FLOW PATH GRID MERIDIANVA NORTH ZONE NAD83TC FLOW PATH TC FLOW PATH STUDY POINT #4 STUDY POINT #5 STUDY POINT #2 STUDY POINT #3 STUDY POINT #1 STUDY POINT #6 5 ONSITE 5A OFFSITE 4 ONSITE 4A OFFSITE 3 ONSITE 3A OFFSITE 1A OFFSITE 1 ONSITE 2 ONSITE 1C ONSITE 1B OFFSITE 2AO OFFSITE 2A ONSITE TC FLOW PATH TC FLOW PATH GRID MERIDIANVA NORTH ZONE NAD83TC FLOW PATH TC FLOW PATH STUDY POINT #4 STUDY POINT #5 STUDY POINT #2 STUDY POINT #3 STUDY POINT #1 STUDY POINT #6 2A ONSITE DETAINED WET POND #3 LEVEL 1 2AO OFFSITE DETAINED WET POND #1 LEVEL 1 6 ONSITE UNDETAINED 2U2 ONSITE UNDETAINED 2 ONSITE UNDETAINED2 ONSITE UNDETAINED 2O OFFSITE UNDETAINED 2U2 ONSITE UNDETAINED 1C ONSITE UNDETAINED 1B OFFSITE UNDETAINED 1 ONSITE UNDETAINED 2 ONSITE DETAINED 4 ONSITE DETAINED 4 ONSITE DETAINED 4 OFFSITE DETAINED 3 OFFSITE UNDETAINED 1A OFFSITE UNDETAINED 4 ONSITE UNDETAINED 5 OFFSITE UNDETAINED 5 ONSITE UNDETAINED 3 ONSITE UNDETAINED WET POND #2 LEVEL 1 FOCAL POINT 3 ONSITE UNDETAINED JELLY FISH BIO-RETENTION LEVEL 1 250 0 250 500 SCALE: 1 250 250 0 250 500 SCALE: 1 250 1 250 20 05/15/2025 ZJ, KAS ---- 51 3924L STORMWATER MANAGEMENT & BEST MANAGEMENT PRACTICES SUMMARY THE WATER QUALITY REQUIREMENTS WILL BE MET BY THE PROPOSED LEVEL 1 WET PONDS, A FOCALPOINT BMP, A LEVEL 1 BIO-RETENTION BMP, A JELLYFISH FILTER DEVICE, UTILIZING FOREST/OPEN SPACE, AND PURCHASING OFFSITE NUTRIENT CREDITS. THE STORM WATER QUANTITY REQUIREMENTS (CHANNEL AND FLOOD PROTECTION) WERE MET BY THE PROPOSED WET PONDS FOR STUDY POINT 2 & 4. STUDY POINTS 1, 3, 5, & 6 HAVE REDUCED DRAINAGE AREAS TO MEET STORM WATER REQUIREMENTS. SITE BOUNDARY DRAINAGE AREA LABELS DRAINAGE DIVIDES ONSITE DRAINAGE AREAS TREATED BY SWM DEVICE SWM LEGEND 1-9 OFFSITE DRAINAGE AREAS TO SWM DEVICE (UNCONTROLLED)151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVSTORMWATER MANAGEMENT PLANRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 06Feb2026 A BLEHIGH DR.THORN TON DR . TY E DR . ROYC E D R.LEHIGH DR . RO S S UM L N .MENASHA CT . LEHIGH D R .L99L98L 9 7 L96L95L94L93L92L 9 1 L90L89L88L87 L86L85 L84 L 8 3 L 8 2L81L80L79L78L77L 7 6 L75L74L73L72L71L70 L69 L66L65L64L63L62L61 L 6 0 L59L58L57L56 L 5 5 L54L 5 3 L52L51L50L49 L 1 4 L13L 1 2 L 1 1 L 1 0 L9L8 L7 L6L5 L4 L3L2L1 GRID MERIDIANVA NORTH ZONE NAD83PROJECT SITE AREA FOR VRRM COMPUTATIONS PROJECT SITE AREA FOR VRRM COMPUTATIONS PROJECT SITE AREA FOR VRRM COMPUTATIONS PROJECT SITE AREA FOR VRRM COMPUTATIONS WET POND #2 LEVEL 1 FOCALPOINT MANUFACTURED TREATMENT DEVICE - FILTERING DA=2.47 ACRES RUNOFF REDUCTION COMPLIANCE FOREST/ OPEN SPACE RUNOFF REDUCTION COMPLIANCE FOREST/ OPEN SPACE LEHIGH DR.WET POND #1 LEVEL 1 L 3 5 L34LINE BEARING DISTANCE L1 S 80°27'11" E 798.83' L2 S 18°33'43" W 288.37' L3 S 31°53'09" E 187.45' L4 S 75°23'27" W 143.31' L5 N 85°29'50" W 52.44' L6 N 30°38'37" W 15.93' L7 S 70°46'09" W 40.78' L8 S 64°29'53" W 45.97' L9 N 24°11'02" W 239.07' L10 N 37°08'51" W 142.67' L11 N 42°11'25" W 108.57' L12 N 54°53'20" W 241.90' L13 N 35°00'36" W 46.54' L14 N 51°45'10" W 43.71' L15 N 82°06'54" W 70.39' L16 S 87°48'53" W 90.40' L17 S 36°59'17" W 18.55' L18 S 32°44'09" W 27.25' L19 S 74°55'07" W 19.83' L20 S 89°13'19" W 91.44' L21 N 81°45'41" W 50.36' L22 N 88°24'38" W 26.96' L23 N 66°52'53" W 26.18' L24 N 22°05'46" W 33.85' L25 N 07°21'24" W 25.55' L26 N 32°30'47" E 31.07' L27 S 79°27'55" W 62.45' L28 N 71°00'45" W 109.64' L29 N 77°40'05" W 52.67' L30 N 77°40'05" W 24.34' L31 N 66°24'19" W 40.69' L32 S 75°07'28" W 60.48' L33 N 16°48'16" E 39.88' L34 N 16°48'16" E 68.58' L35 S 52°58'51" E 103.44' L36 S 67°51'36" E 22.19' L37 S 89°54'38" E 28.71' L38 S 74°33'02" E 28.38' L39 S 63°04'09" E 43.13' L40 S 80°27'12" E 30.85' L41 S 87°29'57" E 24.87' L42 N 63°28'37" E 18.21' L43 N 84°08'17" E 84.47' L44 N 79°05'34" E 47.16' L45 S 11°26'14" E 13.68' L46 N 80°38'01" E 32.13' L47 N 10°39'56" W 14.54' L48 N 79°05'34" E 54.03' L49 N 65°01'19" E 37.71' L50 N 38°00'24" E 31.63' L51 N 06°52'11" E 43.34' L52 N 13°36'02" W 48.30' L53 N 44°33'50" W 82.35' L54 N 14°34'30" W 49.69' L55 N 42°31'46" W 40.94' L56 N 75°47'21" W 80.21' L57 N 27°11'23" W 56.83' L58 N 06°16'20" W 291.31' L59 N 17°44'40" W 102.78' L60 S 38°48'15" E 25.32' L61 N 70°46'09" E 50.00' L62 N 00°04'39" E 25.61' L63 N 37°50'53" E 139.64' L64 S 19°34'48" E 522.03' L65 S 71°41'25" E 266.19' L66 S 18°18'41" W 293.60' L67 S 18°18'09" W 62.20' L68 S 18°18'57" W 96.24' L69 N 63°25'36" E 23.52' L70 N 82°31'32" E 39.82' L71 S 02°34'44" W 73.02' L72 S 09°11'43" E 68.97' L73 S 17°23'14" E 48.94' L74 S 23°52'30" E 140.64' L75 S 36°30'59" E 84.15' L76 S 42°24'24" E 153.98' L77 S 03°50'09" W 42.94' L78 S 36°37'24" E 40.28' L79 S 32°22'58" E 56.61' L80 S 32°22'58" E 30.73' L81 S 29°59'04" E 91.69' L82 S 45°21'06" E 121.76' L83 S 44°06'42" E 139.16' L84 N 80°38'41" W 568.92' L85 N 24°48'19" E 44.84' L86 S 73°36'14" E 172.63' L87 N 88°08'36" E 89.83' L88 N 10°17'24" E 58.28' L89 N 27°15'27" W 155.56' L90 N 35°35'08" W 77.53' L91 N 39°24'19" W 83.69' L92 N 28°04'31" W 29.29' L93 N 36°16'58" W 31.55' L94 N 34°09'57" W 53.52' L95 N 27°12'54" W 131.74' L96 N 07°25'48" W 150.41' L97 N 42°17'35" W 42.60' L98 N 06°36'33" E 47.08' L99 N 24°44'17" E 49.49' LINE BEARING DISTANCE LINE BEARING DISTANCE L100 N 51°28'22" E 137.99' L101 N 21°33'21" E 59.96'151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV1" 100' 21 05/15/2025 ZJ, KAS ---- 51 3924L VRRM PROJECT SITE AREA LIMITS DRAINAGE AREA LABELS VRRM SITE AREA TREATED BY BMP DEVICES (WET PONDS & FOCALPOINT) BMP LEGEND A, B, C, D, E RUNOFF REDUCTION COMPLIANCE FOREST/OPEN SPACE FOR BMP WATER QUALITY IMPERVIOUS AREA (BUILDINGS, ROADS, ETC.) SOIL GROUP SOIL GROUP LETTER NOTES: 1.THE RUNOFF REDUCTION COMPLIANCE FOREST/OPEN SPACE AREA SHOWN HEREON SHALL BE MAINTAINED IN A FOREST/OPEN SPACE MANNER UNTIL SUCH TIME THAT AN AMENDED SWM PLAN IS APPROVED BY THE VSMP AUTHORITY. 2.THE RUNOFF REDUCTION COMPLIANCE FOREST/OPEN SPACE ARE THE UPLAND AREAS ADJACENT TO STREAM SEGMENTS "AB" & "EF" AS IDENTIFIED IN THE WETLAND REPORT. THE PROTECTED FOREST/OPEN SPACE IS SHOWN GRAPHICALLY ON THIS SHEET AND THE BOUNDARY DESCRIPTION IS LISTED IN THE TABLES BELOW. 3.THE PROTECTED FOREST/OPEN FOR RUNOFF REDUCTION COMPLIANCE SHALL REMAIN IN A NATURAL, VEGETATED STATE. HOWEVER THE FOLLOWING ACTIVITIES ARE ALLOWED: FOREST MANAGEMENT, CONTROL OF INVASIVE SPECIES, REPLANTING AND REVEGETATING, PASSIVE RECREATION (TRAILS), LIMITED BRUSH HOGGING. 4.ALL AREAS THAT WILL ARE CONSIDERED FOREST/OPEN SPACE FOR RUNOFF REDUCTION SHALL BE PROTECTED WITH DOCUMENTATION THAT PRESCRIBES THE AREA WILL REMAIN IN A NATURAL, VEGETATED STATE. APPROPRIATE DOCUMENTATION INCLUDES: SUBDIVISION COVENANTS AND RESTRICTIONS, DEEDED OPERATION AND MAINTENANCE AGREEMENTS AND PLANS, PARCEL OF COMMON OWNERSHIP WITH MAINTENANCE PLAN, THIRD PARTY PROTECTIVE EASEMENTS, WITHIN PUBLIC RIGHT-OF-WAY OR EASEMENT WITH MAINTENANCE PLAN, OR OTHER DOCUMENTATION APPROVED BY THE LOCAL PROGRAM AUTHORITY. BOUNDARY DESCRIPTION (LINE TABLE) FOR THE PROTECTED FOREST/ OPEN SPACE - RUNOFF REDUCTION COMPLIANCE MATCH LINE SHEET 22 PHASE 1 PHASE 2 NEW CLOSURE OF REMAINING CONSERVATION EASEMENT CONSERVATION EASEMENT LINE WORK TO BE VACATED WATER QUALITY BMP MAPRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE II100 0 100 200 SCALE: 1" 100' 50 Rev. No.Date DRAINAGE DIVIDES 06Feb2026 L68L67L52L51L50L49 L48 L47L22 L21 L20 L19 L18L17L16 L15 RUNOFF REDUCTION COMPLIANCE FOREST/OPEN SPACE PROJECT SITE AREA FOR VRRM COMPUTATIONS RIVANNA PL.GAP RUN DR. RIVANNA PL.GRID MERIDIANVA NORTH ZONE NAD83WET POND #3 LEVEL 1 BIORETENTION LEVEL 1 - FILTERING DA=1.64 ACRES C JELLYFISH FILTER - FILTERING DA=0.80 ACRES L44 L43 L41L40 L3 9 L38L37L36 L 3 5 L34L33L32 L31 L30 L29 L27 L25L24L46L45 L26L23 L42 L28CONSERVATION EASEMENT AREA TO BE VACATED LEHIGH DR.L100 L101NEW CLOSURE OF REMAINING CONSERVATION EASEMENT LINE BEARING DISTANCE L1 S 80°27'11" E 798.83' L2 S 18°33'43" W 288.37' L3 S 31°53'09" E 187.45' L4 S 75°23'27" W 143.31' L5 N 85°29'50" W 52.44' L6 N 30°38'37" W 15.93' L7 S 70°46'09" W 40.78' L8 S 64°29'53" W 45.97' L9 N 24°11'02" W 239.07' L10 N 37°08'51" W 142.67' L11 N 42°11'25" W 108.57' L12 N 54°53'20" W 241.90' L13 N 35°00'36" W 46.54' L14 N 51°45'10" W 43.71' L15 N 82°06'54" W 70.39' L16 S 87°48'53" W 90.40' L17 S 36°59'17" W 18.55' L18 S 32°44'09" W 27.25' L19 S 74°55'07" W 19.83' L20 S 89°13'19" W 91.44' L21 N 81°45'41" W 50.36' L22 N 88°24'38" W 26.96' L23 N 66°52'53" W 26.18' L24 N 22°05'46" W 33.85' L25 N 07°21'24" W 25.55' L26 N 32°30'47" E 31.07' L27 S 79°27'55" W 62.45' L28 N 71°00'45" W 109.64' L29 N 77°40'05" W 52.67' L30 N 77°40'05" W 24.34' L31 N 66°24'19" W 40.69' L32 S 75°07'28" W 60.48' L33 N 16°48'16" E 39.88' L34 N 16°48'16" E 68.58' L35 S 52°58'51" E 103.44' L36 S 67°51'36" E 22.19' L37 S 89°54'38" E 28.71' L38 S 74°33'02" E 28.38' L39 S 63°04'09" E 43.13' L40 S 80°27'12" E 30.85' L41 S 87°29'57" E 24.87' L42 N 63°28'37" E 18.21' L43 N 84°08'17" E 84.47' L44 N 79°05'34" E 47.16' L45 S 11°26'14" E 13.68' L46 N 80°38'01" E 32.13' L47 N 10°39'56" W 14.54' L48 N 79°05'34" E 54.03' L49 N 65°01'19" E 37.71' L50 N 38°00'24" E 31.63' L51 N 06°52'11" E 43.34' L52 N 13°36'02" W 48.30' L53 N 44°33'50" W 82.35' L54 N 14°34'30" W 49.69' L55 N 42°31'46" W 40.94' L56 N 75°47'21" W 80.21' L57 N 27°11'23" W 56.83' L58 N 06°16'20" W 291.31' L59 N 17°44'40" W 102.78' L60 S 38°48'15" E 25.32' L61 N 70°46'09" E 50.00' L62 N 00°04'39" E 25.61' L63 N 37°50'53" E 139.64' L64 S 19°34'48" E 522.03' L65 S 71°41'25" E 266.19' L66 S 18°18'41" W 293.60' L67 S 18°18'09" W 62.20' L68 S 18°18'57" W 96.24' L69 N 63°25'36" E 23.52' L70 N 82°31'32" E 39.82' L71 S 02°34'44" W 73.02' L72 S 09°11'43" E 68.97' L73 S 17°23'14" E 48.94' L74 S 23°52'30" E 140.64' L75 S 36°30'59" E 84.15' L76 S 42°24'24" E 153.98' L77 S 03°50'09" W 42.94' L78 S 36°37'24" E 40.28' L79 S 32°22'58" E 56.61' L80 S 32°22'58" E 30.73' L81 S 29°59'04" E 91.69' L82 S 45°21'06" E 121.76' L83 S 44°06'42" E 139.16' L84 N 80°38'41" W 568.92' L85 N 24°48'19" E 44.84' L86 S 73°36'14" E 172.63' L87 N 88°08'36" E 89.83' L88 N 10°17'24" E 58.28' L89 N 27°15'27" W 155.56' L90 N 35°35'08" W 77.53' L91 N 39°24'19" W 83.69' L92 N 28°04'31" W 29.29' L93 N 36°16'58" W 31.55' L94 N 34°09'57" W 53.52' L95 N 27°12'54" W 131.74' L96 N 07°25'48" W 150.41' L97 N 42°17'35" W 42.60' L98 N 06°36'33" E 47.08' L99 N 24°44'17" E 49.49' LINE BEARING DISTANCE LINE BEARING DISTANCE L100 N 51°28'22" E 137.99' L101 N 21°33'21" E 59.96'151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV1" 60' 22 05/15/2025 ZJ, KAS ---- 51 3924L MATCH LINE SHEET 21 BOUNDARY DESCRIPTION (LINE TABLE) FOR THE PROTECTED FOREST/ OPEN SPACE - RUNOFF REDUCTION COMPLIANCE NOTES: 1.THE RUNOFF REDUCTION COMPLIANCE FOREST/OPEN SPACE AREA SHOWN HEREON SHALL BE MAINTAINED IN A FOREST/OPEN SPACE MANNER UNTIL SUCH TIME THAT AN AMENDED SWM PLAN IS APPROVED BY THE VSMP AUTHORITY. 2.THE RUNOFF REDUCTION COMPLIANCE FOREST/OPEN SPACE ARE THE UPLAND AREAS ADJACENT TO STREAM SEGMENTS "AB" & "EF" AS IDENTIFIED IN THE WETLAND REPORT. THE PROTECTED FOREST/OPEN SPACE IS SHOWN GRAPHICALLY ON THIS SHEET AND THE BOUNDARY DESCRIPTION IS LISTED IN THE TABLES BELOW. 3.THE PROTECTED FOREST/OPEN FOR RUNOFF REDUCTION COMPLIANCE SHALL REMAIN IN A NATURAL, VEGETATED STATE. HOWEVER THE FOLLOWING ACTIVITIES ARE ALLOWED: FOREST MANAGEMENT, CONTROL OF INVASIVE SPECIES, REPLANTING AND REVEGETATING, PASSIVE RECREATION (TRAILS), LIMITED BRUSH HOGGING. 4.ALL AREAS THAT WILL ARE CONSIDERED FOREST/OPEN SPACE FOR RUNOFF REDUCTION SHALL BE PROTECTED WITH DOCUMENTATION THAT PRESCRIBES THE AREA WILL REMAIN IN A NATURAL, VEGETATED STATE. APPROPRIATE DOCUMENTATION INCLUDES: SUBDIVISION COVENANTS AND RESTRICTIONS, DEEDED OPERATION AND MAINTENANCE AGREEMENTS AND PLANS, PARCEL OF COMMON OWNERSHIP WITH MAINTENANCE PLAN, THIRD PARTY PROTECTIVE EASEMENTS, WITHIN PUBLIC RIGHT-OF-WAY OR EASEMENT WITH MAINTENANCE PLAN, OR OTHER DOCUMENTATION APPROVED BY THE LOCAL PROGRAM AUTHORITY. PHASE - 1 PHASE - 2 NEW CLOSURE OF REMAINING CONSERVATION EASEMENT CONSERVATION EASEMENT LINE WORK TO BE VACATED WATER QUALITY BMP MAP (2)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE II60 0 60 120 SCALE: 1" 60' 30 Rev. No.Date VRRM PROJECT SITE AREA LIMITS DRAINAGE AREA LABELS VRRM SITE AREA TREATED BY BMP DEVICES (WET PONDS & FOCALPOINT) BMP LEGEND A, B, C, D, E RUNOFF REDUCTION COMPLIANCE FOREST/OPEN SPACE FOR BMP WATER QUALITY IMPERVIOUS AREA (BUILDINGS, ROADS, ETC.) SOIL GROUP SOIL GROUP LETTER DRAINAGE DIVIDES 06Feb2026 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV1 = 60 23 05/15/2025 ZJ, KAS ---- 51 3924LVRRM COMPSRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIPHOSPHOROUS SUMMARY PHASE I & II TOTAL REDUCTION REQUIREMENT = 39.80 LBS PHASE I & II ONSITE REDUCTION = -30.17 LBS (75.8% ONSITE TREATMENT) PHASE I PHOSPHOROUS CREDIT PURCHASE = -7.51 LBS ADDITIONAL CREDIT PURCHASE REQUIRED FOR PHASE II = 2.12 LBS Rev. No.Date 06Feb2026 FG/277/2777/27767.6%5.4%5.0%3.4%6/$% 6.56/$% 63.56/$% 64.9975WEIR9975WEIR9975WEIR9975WEIR9300SUMP9525SUMP54$$%%/(9(/:(7321'3F25(%$<:(,5&/$66,5,35$37 6,1&+(6&/$66$5,35$3287/(73527(&7,2115.0' 15. 0 '53.5545655.55.755.5605.560604605.560606600600606046055.755.755.5600600.75600.755.755.75565.755.755.55565466066060460605.755655.55.56006006 0 0 . 7 5 6 0 0 . 7 5 6004.0' 10.0'10.0'10.0 '10.0 ' 10.0'10.0'10.0' 5.0' 5.0'5.0'5.0'5.0' 3 3 1 2 . 0 '$48$7,&%(1&+$48$7,&%(1&+$48$7,&%(1&+$ 4 8 $ 7 , & % ( 1 & +6$F(7<%(1&+6$F(7<%(1&+6 $ F ( 7 < % ( 1 & +$48$7,&%(1&+$48$7,&%(1&+6$F(7<%(1&+6$F(7<%(1&+600505565456046056005055654560565545333  .%5%%% 5% % 0% 0% 5%%%5%605,6(5723 60.0025,F,&( 5.756  0 6  0 6 3 0 6   6  6 6   6  4 6  6 6   6   6  4 6 0 6 31JF30101111A121314156  4 66666  0604606000500000500050005030057057550555055600605606557057550555055600605606535 0,11250$/322/:6( 5.75 7Y 067IW3  34 0',3 321''5$,1 #3.6%50.7 35,1&,3$/5,6(5 ,19287 55.50 ,19,1 5.4 0',3 723 60.00 605,6(5 00<5:6( 603.400<5:6( 60.5<5:6( 60.53&21752//('F,//(0%$1.0(1772%(&216758&7(':,7+&/$<&25(6,'(6/23(6&872FF75(1&+4.0 0,1.'(37+:,7+6,'(6/23(625F/$77(5&21&5(7(&5$'/(6(('(7$,/7+,66+((70 $48$7,&%(1&+0 6$F(7<%(1&+3523.G5$'((;.G5$'(3+5($7,&/,1(6((67250352F,/(6216+((734.%0,1.(;7(1'&872FF75(1&+72%$6(2F287F$//3,3((;&$9$7,21.4 0',3321' '5$,1:,7+837851(' (/%2: ,19287 53.5 5$:(7321'3&52666(&7,21$+ 50 9 5 321'72%(/,1('3(5G(27(&+1,&$/5(32575(48,5(0(1767232F(0%$1.0(17(/(9 605.5'5$,1$G(%/$1.(772'$</,G+76(('(7$,/7+,66+((7 45&3#.50% :7-2,176 0,1 &/$</,1(50,1672362,/&$3050000050005055505560060555505560060560605 $48$7,&%(1&+5 6$F(7<%(1&+F25(%$<1250$/322/:6( 5.75 7Y 5IW3 00<5:6( 603.40<5:6( 60.530<5:6( 60.53:(7321'3&52666(&7,21%+ 50 9 5 0,1 &/$</,1(5:0,1672362,/&$35800INV/SS5800INV/SS5800SS5800SS3.5 7.4 15.7 &/$665,35$36(('(7$,/6+((730&/$66$5,35$3.5 5:LQG\+LOO/DQH :LQFKHVWHU9LUJLQLD60 7HOHSKRQH 540 6645 FD[ 540 75 ZZZ.JUHHQZD\HQJ.FRP FND 1971 E N G I N E E R I N G6+((72F'(6,G1('%<F,/(12.6&$/('$7(3528'/<6(59,1G9,5G,1,$ :(679,5G,1,$ 2FF,&(6,1:,1&+(67(59$$6+%8519$ 0$57,16%85G:95HY.1R.'DWH321'3 :3 3/$1 6(16(1<9,//$G( 5('%8'0$G,67(5,$/',675,&7 F5('(5,&.&2817<9,5G,1,$$66+2:1405505=-.$6534/127(6.7+(00<($5:$7(5685F$&((/(9$7,21 :6( $6680(6$//23(1,1G6%(/2:7+(7232F7+(5,6(5$5(&/2GG('$1'7+(67$57,1G:6(,67+(7232F7+(5,6(5..$//67250:$7(50$1$G(0(17F$&,/,7,(672%(&(57,F,('%<$G(27(&+1,&$/(1G,1((525&216758&7,21,163(&725.3.(0%$1.0(17&21752//('F,// 62,/0$7(5,$/6 72%(&(57,F,('%<$G(27(&+1,&$/(1G,1((5.4.5(F(572G(1(5$/127(63(50$1(176:0(0%$1.0(17127(6216+((7.5.321'287F$//3,3(6+$//%(%(''(':,7+F,1(G5$,1('62,/6.F,1(G5$,1('62,/66+$//+$9(6721(25/(66,1',$0(7(5F25$0,1,0802F $5281'3,3(,1$5($62F%$&.F,//.6.&/$<&25(4 0,1,080:,'7+67$57,1G$77+(0<5:6(25+,G+(5:,7+6,'(6/23(6253(5G(27(&+1,&$/5(3257G8,'$1&(.7.&872FF75(1&+4 0,1,080:,'7+67$57,1G4 %(/2:(;,67,1GG5$'(25$7%277202F(;&$9$7,21F25287F$//3,3(:+,&+(9(5,6G5($7(5:,7+6,'(6/23(6253(5G(27(&+1,&$/5(3257G8,'$1&(..&2168/7G(27(&+,1,&$/5(3257F2572(%/$1.(7$1'25&+,01(<'5$,15(48,5(0(176.&2168/7G(27(&+1,&$/5(3257F25/,1(55(48,5(0(1760,1,080/,1(55(48,5(0(1763529,'('%(/2:,F5(48,5('.0.&216758&7,2172&203/<:,7+5(&200(1'$7,216F520G(27(&+1,&$/5(3257.45&3 :.7.-2,176 5 0.75 7232F5,6(5(/(9 60.007<3.75$6+5$&.%<3/$67,&62/87,2125$33529('(48$/(/(9 55.5025,F,&( 5.756.67 .3 0,1,08035(&$675&3%$6($1'5,6(56758&785( 9'27$4&21&5(7( 0,167+,&.:$//6(',0(17%$6,1321'335,1&,3$/5,6(56(&7,21176&21&5(7(F,//F25%82<$1&<13:6(/(95.757232F(0%$1.0(17(/(9 605.5000<5:6 603.40,19. 5.4,19. 53.5 ',3'5$,1:,7+9$/9( 1250$//<&/26(' G$7(9$/9(:,7+67(0+$1':+((/ 7<3 67(0G8,'( 7<3 &21&5(7(%/2&.6F259$/9(6833257837851('(/%2: 0ƒ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eb2026 LOT 29LOT 30LOT 32LOT 33SLAB=617.58SLAB=619.64SLAB=620.31SLAB=617.58SLAB=616.9211A41401184OLR0951INV0950FS0900SS0900MEDIA612"A""A"3:1 3:161261 2 6166146146166186166126146106 1 2 6 1 4 6 1 0 6106106166096 0 9 609CLASS A1 RIPRAP OUTLETPROTECTIONAND #1 STONEFLOWSPREADER24" NYLOPLASTW/DOME GRATETOP = 610.00CLEANOUT(TYP.)WYE (TYP.)6" PVC UNDERDRAIN6226226246 1 8 6 1 6 6 1 4 6186166106086126146046 2 0-0+500+000+501+001+50600605610615620625600605610615620625BIORETENTION CROSS SECTION "A"H: 1"=50'V: 1"=5'11BNYP-24 DOME TOP = 610.00 SYNTHETICLINERINSTALLPERMANUFACTURERREQUIREMENTS(ENTIREFACILITY)6" PVC PERFORATEDUNDERDRAIN @0.0% W/3' WIDE FILTER FABRICCENTERED OVER TOP OFPIPE (605.25)SEE SHEET 34 FORCONTINUATION OFSTORM PROFILE595595NON-WOVENGEOTEXTILEPROPOSEDGRADEE X . G R A D EMEDIA ANDGRAVELLAYERS, SEEMATERIALCROSSSECTIONTHIS SHEETTOP OF MEDIA= 609.0040EW-1 (15)10 YRWSE=611.12WQ WSE=610.00VDOT #1 STONE FLOWSPREADER(SEE DETAIL)CLASS A1 RIPRAPBIORETENTION 1 PLAN AND JELLYFISH DETAILS SENSENY VILLAGE RED BUD MAGISTERIAL DISTRICT FREDERICK COUNTY, VIRGINIA 151 Windy Hill Lane Winchester, Virginia 22602 Telephone: (540) 662-4185 Fax: (540) 722-9528 www.greenwayeng.com FND 1971 E N G I N E E R I N GSHEET OFDESIGNED BY:FILE NO.SCALE:DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIA OFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVAS SHOWN2505/15/2025ZJ, KAS----513924LBIO LVL 1 MATERIAL CROSS SECTIONNTSNOTES1.CONSTRUCTION TO COMPLY WITH RECOMMENDATIONS FROM THE GEOTECHNICAL REPORT.2.THE CONSTRUCTION OF SWM OR BMP FACILITIES SHALL BE INSPECTED AND CERTIFIED BY A PROFESSIONALENGINEER OR DEQ CERTIFIED INSPECTOR.3.ALL FILTER MEDIA MUST BE PROVIDED BY A QUALIFIED CERTIFIED VENDOR AND MEET THE MATERIAL ANDTESTING REQUIREMENTS PER THE VA STORMWATER DESIGN SPECIFICATION AND AS NOTED ON THIS PLAN.4.DURING THE INSTALLATION OF SWM AND BMP FACILITIES, ALL INFRASTRUCTURE AND MATERIALS (E.G.UNDERDRAINS, CONCRETE CRADLE, VARIOUS STONE AND FILTER MEDIA, ALONG WITH ASSOCIATEDTHICKNESS) TO BE BURIED MUST BE PHOTOGRAPHED DURING INSTALLATION. THIS INFORMATION IS TO BEPROVIDED WHEN THE GENERAL PERMIT NOTICE OF TERMINATION (NOT) FORM IS SUBMITTED AND PRIOR TOFINAL SITE INSPECTION. DAILY FIELD REPORTS AND COMPACTION REPORTS SHOULD ALSO BE INCLUDED WITHTHE NOT FORM.5.BIORETENTION FACILITIES REQUIRE INTERIM CONSTRUCTION INSPECTIONS AS OUTLINED IN THE VA DEQ SWMHANDBOOK. AT A MINIMUM THE FOLLOWING CONSTRUCTION PHASES SHALL BE INSPECTED EXCAVATIONPHASE, STONE RESERVOIR PHASE & MEDIA PHASE.6.FILTER FABRIC SHALL BE PLACED DIRECTLY OVER THE UNDERDRAIN AND EXTEND 1' TO 2' ON EITHER SIDE OFTHE UNDERDRAIN BEFORE THE CHOKER STONE IS PLACE FOR BIORETENTION FACILITIES7.WATER QUALITY FEATURES SHALL NOT BE CONSTRUCTED UNTIL ALL UPSTREAM DRAINAGE IS FULLYSTABILIZED WITH PERMANENT GROUND COVER.8.ALL ENGINEERED MEDIA BED AREAS SHALL BE PROTECTED WITH SILT FENCE AND/OR GEOTEXTILE UPONINSTALLATION AND SHALL REMAIN IN PLACE UNTIL ALL UPSTREAM AREAS DISTURBED DURING INSTALLATIONARE FULLY STABILIZED WITH GRASS OR SOD.6" PVC SCREWCAP ON GRADE6" PVCNON-PERFORATEDSTANDPIPEUSE 45° WYE AND FITTING OREQUIVALENT DIRECTIONALCLEANOUT TO CONNECT UNDERDRAIN TO STANDPIPE6" PVC CLEANOUT DETAILGEOTEXTILEFABRICENGINEERED SOILLAYER12" MIN. GRAVELLAYER6" PVC UNDERDRAINqTV = 0.80CFSRev. No.Date 06Feb2026 POND 1 (WP PH I) UPDATE SENSENY VILLAGE RED BUD MAGISTERIAL DISTRICT FREDERICK COUNTY, VIRGINIA 151 Windy Hill Lane Winchester, Virginia 22602 Telephone: (540) 662-4185 Fax: (540) 722-9528 www.greenwayeng.com FND 1971 E N G I N E E R I N GSHEET OFDESIGNED BY:FILE NO.SCALE:DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIA OFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVAS SHOWN2605/15/2025ZJ, KAS----513924LPHASE 1 POND 1 PROFILE FROM APPROVED PLANREVISED 100 YRWSE= 575.35REVISED 10 YRWSE= 574.12REVISED 1 YRWSE= 573.14POND 1 NARRATIVEPOND 1 WAS DESIGNED AND PERMITTED WITH SENSENY VILLAGE PHASE I.ADDITIONAL DETENTION AND TREATMENT VOLUME WAS INCLUDED WITHINTHE POND DESIGN TO ACCOMMODATE AREAS DEVELOPED WITH PHASE II.HYDROCAD ANALYSIS OF THE POND IS INCLUDED WITHIN THE SWM REPORTPUBLISHED FOR PHASE II. PROFILE AND PLAN VIEW ON THIS SHEET COMESFROM THE APPROVED PLAN (APPROVAL DATE: AUGUST 8, 2023) FOR PHASE IAND MARK UPS HAVE BEEN PROVIDED FOR WATER SURFACE ELEVATIONINCREASES DUE TO PHASE II DEVELOPMENT. REQUIRED FREEBOARD ISMAINTAINED WITH THE ADDED DRAINAGE AREA AND POST DEVELOPMENTFLOWS ARE COMPLIANT.WATER QUALITY TREATMENT VOLUME:REQUIRED TREATMENT VOLUME FROM PHASE I DESIGN = 49,540 FT3REVISED REQUIRED TREATMENT VOLUME = 51,372 FT3PROVIDED TREATMENT VOLUME = 57,706 FT3(PROFILE FROM PHASE I NOTED 50,082 FT3 AS THE TREATMENT VOLUME ASCONSERVATIVE, PROVIDED TREATMENT VOLUME HAS BEEN UPDATE ON THEPROFILE AND DOES NOT INCLUDE VOLUME PROVIDED IN THE FOREBAYMAKING THE NOTED TREATMENT VOLUME CONSERVATIVE. TREATMENTVOLUME VERIFIED IN HYDROCAD)Tv=57,706 ft3(VERIFIED INHYDROCAD)PHASE 1 POND 1 PLAN VIEW FROM APPROVED PLANRev. No.Date 06Feb2026 RIVANNA PL (PRIVATE) COMPACT FILL PER GEOTECHNICAL REPORT PROPOSED GRADE 50' ROW 4" SAN LAT LOT 174" SAN LAT LOT 184" SAN LAT LOT 194" SAN LAT LOT 204" SAN LAT LOT 214" SAN LAT LOT 224" SAN LAT LOT 234" SAN LAT LOT 244" SAN LAT LOT 254" SAN LAT LOT 264" SAN LAT LOT 274" SAN LAT LOT 284" SAN LAT LOT 294" SAN LAT LOT 30EXISTING GRADE CD-1 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 590 595 600 605 610 615 620 625 630 635 640 645 650 590 595 600 605 610 615 620 625 630 635 640 645 650611.50611.81612.12612.44612.75613.03612.75612.44612.25612.06611.88611.69611.48610.93610.59610.50610.64611.03611.64612.29612.76613.24613.72614.82616.35617.87619.38620.65621.90623.15624.36624.89625.39625.89626.39626.89627.78628.77-1.25% -1.25% -0.75%-2.74% -1.91% -1.91%-6.10 %-5.00% -1.99% -3.96%PVC STA.11+20.00PVC ELEV.613.00PVI STA.11+25.00PVI ELEV.613.06PVT STA.11+30.00PVT ELEV.613.00VC = 10.00 SD = 437' K-Val = 4.0 PVC STA.11+72.50PVC ELEV.612.47PVI STA.11+75.00PVI ELEV.612.44PVT STA.11+77.50PVT ELEV.612.42VC = 5.00 SD = 1000' K-Val = 10.0 PVC STA.12+95.00PVC ELEV.611.54PVI STA.13+00.00PVI ELEV.611.50PVT STA.13+05.00PVT ELEV.611.37VC = 10.00 SD = 603' K-Val = 5.5 PVC STA.13+06.00PVC ELEV.611.35PVI STA.13+75.00PVI ELEV.609.59PVT STA.14+44.00PVT ELEV.611.48VC = 138.00 SD = 159' K-Val = 26.1 SAG = 13+72.53 ELEV. = 610.50 PVC STA.14+67.50PVC ELEV.612.12PVI STA.14+70.00PVI ELEV.612.19PVT STA.14+72.50PVT ELEV.612.24VC = 5.00 SD = 1294' K-Val = 6.0 PVC STA.15+50.00PVC ELEV.613.72PVI STA.15+60.00PVI ELEV.613.91PVT STA.15+70.00PVT ELEV.614.52VC = 20.00 SD = 99' K-Val = 4.8 PVC STA.16+45.00PVC ELEV.619.09PVI STA.16+50.00PVI ELEV.619.40PVT STA.16+55.00PVT ELEV.619.65VC = 10.00 SD = 986' K-Val = 9.1 PVC STA.17+45.00PVC ELEV.624.15PVI STA.17+50.00PVI ELEV.624.40PVT STA.17+55.00PVT ELEV.624.50VC = 10.00 SD = 364' K-Val = 3.3 PVC STA.18+72.50PVC ELEV.626.84PVI STA.18+80.00PVI ELEV.626.98PVT STA.18+87.50PVT ELEV.627.28VC = 15.00 SD = 975' K-Val = 7.6 8" SAN XINGCREST = 11+25.00 ELEV. = 613.03 19+34.73 = END ROAD18+31.27 = INTX. 17+46.98 GAP RUN DR. (LOOP) (PRIVATE)11+43.31 = INTX. 10+00 GAP RUN DR. (LOOP) (PRIVATE)10+00 = BEGIN ROAD15+11.09 = INTX. 11+27.48 ENTRANCE12" STORM XING15" STORM XING6" W/L XING15" STORM XING8" W/L XING-2.55 % CD-2, TIE TO STR.12 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVSCALE: 1" = 50' 50 25 0 50 100 SCALE: 1" = 5'50510Rev. No.Date 04 02/06/2026 27 05/15/2025 ZJ, KAS ---- 51 3924L V: 1" = 5' H: 1" = 50' UD-4 3:1 SLO P E ( 6 ) M 6" R/W SR 5' 4' 6" LPLC P LIMITS OF SUB-BASE 1/4":1' LP SL 4' 5' SIDEWALK 6" STANDARD M 6" 3:1 SLO P E ( 6 ) R/W (All units are in feet unless otherwise noted.) LIMITS OF BITUMINOUS SURFACE CONCRETE BITUMINOUS WITH CURB AND GUTTER RESIDENTIAL SUBDIVISION STREETS TYPICAL SECTION FOR 6"6" 2'2' 1' 1'2% 2% SIDEWALK STANDARD CG-6 REVERSE AND CONSTRUCTION CENTERLINE OF RIGHT OF WAYSUB-BASE ROAD PROFILESRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRSSLPMAX. GRADE MIN. C.L.R.O.W.ROAD MIN DESIGN MIN. SIGHT DISTANCE 10.5'10.5'27'280'155'6.1%200'48'RIVIANNA PL WIDTH STOPSPEED (mph)RADIUS INTX. STREET PARKING PARKING ON ONE SIDE M 1' PROJECTED TRAFFIC < 2,000 VOLUME UP TO (ADT) 1/4":1' POINT OF FINISHED GRADE CG-6 STANDARD UD-4 MAY BE OMMITED FROM PRIVATE ROADS. ENGINEER RECOMENDS UD-4 FOR ALL ROADWAYS. RIVANNA PL (PRIVATE) NOT TO SCALE TYPICAL PAVEMENT SECTION NOT TO SCALE TYPICAL PAVEMENT SECTION 10.0" SUBBASE VDOT STD. 21B PLACED IN 2 LIFTS OF 5.0" 1.5" SM-9.5A SURFACE COURSE VDOT VTM-1 METHOD) AT OPTIMUM MOISTURE CONTENT (COMPACTED TO 95% DENSITY COMPACTED SUBGRADE 3" IM-19.0A INTERMEDIATE COURSE SUBGRADE SEPARATION LAYER* *SUBGRADE SEPARATION LAYER REQUIRED FOR THE FOLLOWING CONDITIONS: -MORE THAN 35% SUBGRADE FINES AND/OR -SUBGRADE CBR BETWEEN 3 AND 8 *SUBGRADE SEPARATION LAYER TO BE MIRAFI 140N OR EQUAL PER THE GEOTECHINICAL REPORT. PRELIMINARY PAVEMENT DESIGN BASED ON "FLEXIBLE PAVEMENT SECTION - SUBDIVISION ROADWAYS" FROM GTA GEOTECHNICAL REPORT DATED 02/03/2026. FINAL PAVEMENT DESIGN SHALL BE IN ACCORDANCE WITH VDOT 2018 PAVEMENT DESIGN GUIDE AND BASED UPON ACTUAL FIELD TESTED CBR VALUES OBTAINED IN THE PRESENCE OF A VDOT INSPECTOR. ALL PAVEMENT DESIGNS SHALL BE REVIEWED AND APPROVED BY VDOT PRIOR TO CONSTRUCTION. 06Feb2026 4" SAN LAT LOT 624" SAN LAT LOT 614" SAN LAT LOT 604" SAN LAT LOT 594" SAN LAT LOT 584" SAN LAT LOT 574" SAN LAT LOT 564" SAN LAT LOT 554" SAN LAT LOT 544" SAN LAT LOT 534" SAN LAT LOT 524" SAN LAT LOT 514" SAN LAT LOT 504" SAN LAT LOT 494" SAN LAT LOT 484" SAN LAT LOT 47COMPACT FILL PER GEOTECHNICAL REPORT PROPOSED GRADE EXISTING GRADE GAP RUN DR. (LOOP) (PRIVATE) 50' ROW CD-1 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 590 595 600 605 610 615 620 625 630 635 640 645 650 590 595 600 605 610 615 620 625 630 635 640 645 650612.83613.32614.07615.19616.32617.44618.57619.69620.82621.94623.10624.35625.60626.85628.10629.35630.60631.85633.02633.81634.19634.15633.69632.81631.60630.35629.10627.85626.91626.40-1.97% -4.50 %-5.00% -5. 0 0 % -2.02%PVC STA.10+35.00PVC ELEV.613.52PVI STA.10+40.00PVI ELEV.613.62PVT STA.10+45.00PVT ELEV.613.84VC = 10.00 SD = 266' K-Val = 3.9 PVC STA.12+39.00PVC ELEV.622.57PVI STA.12+44.00PVI ELEV.622.80PVT STA.12+49.00PVT ELEV.623.05VC = 10.00 SD = 1000' K-Val = 20.0 PVC STA.14+35.00PVC ELEV.632.35PVI STA.15+10.00PVI ELEV.636.10PVT STA.15+85.00PVT ELEV.632.35VC = 150.00 SD = 183' K-Val = 15.0 CREST = 15+10.00 ELEV. = 634.22 PVC STA.16+70.00PVC ELEV.628.10PVI STA.16+95.00PVI ELEV.626.85PVT STA.17+20.00PVT ELEV.626.48VC = 50.00 SD = 163' K-Val = 14.2 11+43.31 = INTX. 18+31.27 RIVANNA CT (PRIVATE)10+00 = INTX. 11+43.31 RIVANNA CT (PRIVATE)-1.48% -1.95%8" W/L XING6" W/L XING8" W/L XING8" W/L XING8" W/L XING8" W/L XING8" W/L XING8" W/L XING151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV28 05/15/2025 ZJ, KAS ---- 51 3924L SCALE: 1" = 50' 50 25 0 50 100 SCALE: 1" = 5'50510V: 1" = 5' H: 1" = 50'ROAD PROFILES (2)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIUD-4 3:1 SL O P E ( 6 ) M 6" R/W SR 5' 4' 6" LPLC P LIMITS OF SUB-BASE 1/4":1' LP SL 4' 5' SIDEWALK 6" STANDARD M 6" 3:1 SL O P E ( 6 ) R/W (All units are in feet unless otherwise noted.) LIMITS OF BITUMINOUS SURFACE CONCRETE BITUMINOUS WITH CURB AND GUTTER RESIDENTIAL SUBDIVISION STREETS TYPICAL SECTION FOR 6"6" 2'2' 1' 1'2% 2% POINT OF FINISHED GRADE SIDEWALK STANDARD CG-6 REVERSE AND CONSTRUCTION CENTERLINE OF RIGHT OF WAYSUB-BASE RSSLPMAX. GRADE MIN. C.L.R.O.W.ROAD MIN DESIGN MIN. SIGHT DISTANCE 10.5'10.5'27'280'155'5%200'48'GAP RUN DR. WIDTH STOPSPEED (mph)RADIUS INTX. STREET PARKING PARKING ON ONE SIDE M 1' PROJECTED TRAFFIC < 2,000 VOLUME UP TO (ADT) 1/4":1'CG-6 STANDARD UD-4 MAY BE OMMITED FROM PRIVATE ROADS. ENGINEER RECOMENDS UD-4 FOR ALL ROADWAYS. Rev. No.Date 04 02/06/2026 GAP RUN DR. (PRIVATE) NOT TO SCALE TYPICAL PAVEMENT SECTION NOT TO SCALE TYPICAL PAVEMENT SECTION 10.0" SUBBASE VDOT STD. 21B PLACED IN 2 LIFTS OF 5.0" 1.5" SM-9.5A SURFACE COURSE VDOT VTM-1 METHOD) AT OPTIMUM MOISTURE CONTENT (COMPACTED TO 95% DENSITY COMPACTED SUBGRADE 3" IM-19.0A INTERMEDIATE COURSE SUBGRADE SEPARATION LAYER* *SUBGRADE SEPARATION LAYER REQUIRED FOR THE FOLLOWING CONDITIONS: -MORE THAN 35% SUBGRADE FINES AND/OR -SUBGRADE CBR BETWEEN 3 AND 8 *SUBGRADE SEPARATION LAYER TO BE MIRAFI 140N OR EQUAL PER THE GEOTECHINICAL REPORT. PRELIMINARY PAVEMENT DESIGN BASED ON "FLEXIBLE PAVEMENT SECTION - SUBDIVISION ROADWAYS" FROM GTA GEOTECHNICAL REPORT DATED 02/03/2026. FINAL PAVEMENT DESIGN SHALL BE IN ACCORDANCE WITH VDOT 2018 PAVEMENT DESIGN GUIDE AND BASED UPON ACTUAL FIELD TESTED CBR VALUES OBTAINED IN THE PRESENCE OF A VDOT INSPECTOR. ALL PAVEMENT DESIGNS SHALL BE REVIEWED AND APPROVED BY VDOT PRIOR TO CONSTRUCTION. 06Feb2026 1.75% 5.0 0 %PVC = 29+50.00PVC = 609.54'PVI = 29+75.00PVI = 609.10'PVT = 30+00.00PVT = 607.85'VC = 50' 15.38K-Val AD-3.25 605.35604.10602.98602.07601.38600.90600.64600.60600.77601.15601.76602.58603.61604.74605.86606.99608.11609.2472" BOXCULVERT XINGCOMPACT FILL PER GEOTECHNICAL REPORT. MINIMUM CBR OF 10 REQUIRED. SEE GEOTECHINICAL REPORT. PROPOSED GRADE EXISTING GRADE LEHIGH DRIVE 50' ROW DESIGN SPEED 25 MPH CD-1 28+85.59=INTX. 16+50.56 THORNTON WAY30+19.09=PC30+29.85610.85'610.42'609.98'609.54'608.90'607.85'606.60'605.35'610.67'606.90'606.36'8" SAN. XING48" STORM XINGSD= 357.05 PROP. 8"W/L XING8" SAN. XING30+50 31+00 31+50 32+00 32+50 33+00 33+50 34+00 34+50 35+00 35+50 550 555 560 565 570 575 580 585 590 595 600 605 610 615 620 625 -4.50 %PVC STA.30+72.96PVC ELEV.604.21PVI STA.32+10.46PVI ELEV.597.33PVT STA.33+47.96PVT ELEV.603.52VC = 275.00 SD = 170' K-Val = 28.9 SAG = 32+17.70 ELEV. = 600.59 30+0029+5029+0028+50 30+50 = INTX. 30+50 LEHIGH DR (PHASE 1)34+90.75 = INTX. 10+00 ENTRANCE550 555 560 565 570 575 580 585 590 595 600 605 610 615 620 625 15" STORM XING12" STORM XING12" STORM XING18" STORM XINGCD-2, TIE TO STR.149B AND STR.149E609.94610.44610.94611.54612.88EXISTING GRADE PROPOSED GRADE ENTRANCE 50' ROW DESIGN SPEED 25 MPH 9+50 10+00 10+50 11+00 11+50 595 600 605 610 615 620 625 595 600 605 610 615 620 625 -1.99%8" SAN XING10+00 = INTX. 34+90.75 LEHIGH DR10+22.52 = INTX. 15+11.09 RIVANNA CT (PRIVATE)-2.98%15" STORM XING611.1710+61.50 = R/W LEHIGH DR-2.00%10+11.02 = EP RIVANNA CT (PRIVATE)℄ENTRANCE ROAD=EDGE OF PVM'T ELEV = 610.90-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 590 595 600 605 610 615 620 590 595 600 605 610 615 620 -2.87% -2.59 % LEHIGH DRIVE CUL-DE-SAC EDGE OF PAVEMENT PROFILE 32 33 TOP = 607.89DI-3B - 6'TOP = 607.98DI-3B - 6'PROPOSED GRADE @ EP ROAD STATION = 34+25.01 BEGINCURB RETURN FOR CUL-DE-SACROAD STATION = 34+22.06 ENDCURB RETURN FOR CUL-DE-SACEDGE OF PVM'T = ℄ENTRANCE ROADELEV = 610.90-0+50 0+00 0+50 1+00 1+50 595 600 605 610 615 620 625 595 600 605 610 615 620 625 POND ACCESS DRIVE OFF CUL-DE-SAC PROPOSED GRADE EXISTING GRADE -3.9 8 % PEDESTRIAN ACCESS 4.5' @ 2.00% MAX PEDESTRIAN ACCESS 5' @ 12% MAX EP 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV29 05/15/2025 ZJ, KAS ---- 51 3924L SCALE: 1" = 50' 50 25 0 50 100 SCALE: 1" = 5'50510V: 1" = 5' H: 1" = 50' UD-4 3:1 SL O P E ( 6 ) M 6" R/W SR 5' 4' 6" 1/4":1' RSSLP LPLC P LIMITS OF SUB-BASE 1/4":1' MAX. GRADE MIN. C.L. LP SL 4' 5' R.O.W. SIDEWALK 6" STANDARD M 6" 3:1 SLO P E ( 6 ) ROAD R/W MIN DESIGN MIN. SIGHT DISTANCE (All units are in feet unless otherwise noted.) LIMITS OF BITUMINOUS SURFACE CONCRETE BITUMINOUS 11.5'11.5'27' WITH CURB AND GUTTER RESIDENTIAL SUBDIVISION STREETS TYPICAL SECTION FOR PUBLIC 280'155'5%200'2550'LEHIGH DR WIDTH STOPSPEED (mph)RADIUS INTX. 6"6" 2'2' 1'1' STREET PARKING PARKING ON ONE SIDE M 1' PROJECTED TRAFFIC < 2,000 VOLUME UP TO (ADT) 2%2% POINT OF FINISHED GRADE SIDEWALK STANDARD CG-6 STANDARD AND CONSTRUCTION CENTERLINE OF RIGHT OF WAYSUB-BASE ROAD PROFILES (3)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 04 02/06/2026 MINIMUM CBR OF 10 REQUIRED FOR THE EMBANKMENT FILL. SEE GEOTECHINICAL REPORT. LEHIGH DR. (PUBLIC) NOT TO SCALE TYPICAL PAVEMENT SECTION 8.0" SUBBASE VDOT STD. 21B 1.5" SM-9.5A SURFACE COURSE VDOT VTM-1 METHOD) AT OPTIMUM MOISTURE CONTENT (COMPACTED TO 95% DENSITY COMPACTED SUBGRADE 3" IM-19.0A INTERMEDIATE COURSE PRELIMINARY PAVEMENT DESIGN BASED ON "FLEXIBLE PAVEMENT SECTION - EMBANKMENT ROADWAY" FROM GTA GEOTECHNICAL REPORT DATED 02/03/2026. FINAL PAVEMENT DESIGN SHALL BE IN ACCORDANCE WITH VDOT 2018 PAVEMENT DESIGN GUIDE AND BASED UPON ACTUAL FIELD TESTED CBR VALUES OBTAINED IN THE PRESENCE OF A VDOT INSPECTOR. ALL PAVEMENT DESIGNS SHALL BE REVIEWED AND APPROVED BY VDOT PRIOR TO CONSTRUCTION. LEHIGH DR. (PRIVATE) NOT TO SCALE TYPICAL PAVEMENT SECTION 10.0" SUBBASE VDOT STD. 21B PLACED IN 2 LIFTS OF 5.0" 1.5" SM-9.5A SURFACE COURSE VDOT VTM-1 METHOD) AT OPTIMUM MOISTURE CONTENT (COMPACTED TO 95% DENSITY COMPACTED SUBGRADE 3" IM-19.0A INTERMEDIATE COURSE SUBGRADE SEPARATION LAYER* *SUBGRADE SEPARATION LAYER REQUIRED FOR THE FOLLOWING CONDITIONS: -MORE THAN 35% SUBGRADE FINES AND/OR -SUBGRADE CBR BETWEEN 3 AND 8 *SUBGRADE SEPARATION LAYER TO BE MIRAFI 140N OR EQUAL PER THE GEOTECHINICAL REPORT. MINIMUM CBR OF 10 REQUIRED FOR THE EMBANKMENT FILL. SEE GEOTECHINICAL REPORT. PRELIMINARY PAVEMENT DESIGN BASED ON "FLEXIBLE PAVEMENT SECTION - SUBDIVISION ROADWAYS" FROM GTA GEOTECHNICAL REPORT DATED 02/03/2026. FINAL PAVEMENT DESIGN SHALL BE IN ACCORDANCE WITH VDOT 2018 PAVEMENT DESIGN GUIDE AND BASED UPON ACTUAL FIELD TESTED CBR VALUES OBTAINED IN THE PRESENCE OF A VDOT INSPECTOR. ALL PAVEMENT DESIGNS SHALL BE REVIEWED AND APPROVED BY VDOT PRIOR TO CONSTRUCTION. 06Feb2026 C66 ::LEHIGH DR. 38%/,C 331 11 1 13 13 52 :  75$,/(60772%( )5('(5,C.C2817<;;3: 1 3:1 3:1 3:1 3:1                00 59 LP 00 36 EP/LP 00 36 EP/LP 5800INV/SS5800SS (;326(' C/15,3 5$3%$1. 3 5 2 3 5 2: 352352: 3 52 3 /2'352352$'C/C/$175$3(=2,'$/ 5,35$3/,1(' C+$11(/ (;326(' C/15,3 5$3%$1. 3 5 2 3  5 2: 3523/2'352352:3523/2'3523/2'1 11 1 13 13 (0%(''('C/ 15,35$3 (;326(' C/15,3 5$3 (0%(''('C/ 15,35$3 (;326(' C/15,3 5$3 C/$15,35$3 1 O;1 Z;1G (0%('0(17 1<5:6( 3 <5)8785('(9:6( 3 <5287/(7 9(/2C,7< )36 9'27C/1 5,35$3 (0%(''(' 1 ; /2:)/2:C8/9(57$1'$662C,$7('5,35$372%( (0%(''('%(/2:1$785$/675($0%('$7,1/(7$1'287/(7 :,1*:$//21 ($C+ ; C8/9(57 6((6+((731)25 :,1*:$// 352),/(6  C857$,1 :$//  6,'(:$/.  6,'(:$/.  C857$,1 :$//℄52$'3523:/;,1*35236$1;,1*1111111113131                           13 ,19,1 ,19287 11311 ,1/(7 287/(7   ; %2;C8/9(57#   ; %2;C8/9(5 7  #     136/$%$6680('7 2 3  $ 1 '  % 2 7 7 2 0 % 2 7 7 2 0  2 0 , 7 7 ( '  ) 5 2 0  3 5 2 ) , / (  ) 2 5  C / $ 5 , 7 < :,1*:$//21($C+  ; C8/9(57 6((6+((731)25 :,1*:$// 352),/(6 9'27C/1 5,35$3 (0%(''(' 3:13:1(;*5$'(352326('*5$'(3:13523*5$'( $/21*:: %27720 3523*5$'( $/21*:: %27720 ,19287; 1,19,1; 1<5)8785('(9:6(  C203$C7),//3(5*(27(C+1,C$/5(3257 %('C8/9(573(5*(27(C+1,C$/5(3257  (;326(' C/15,3 5$3%$1.352352:3523/2'          (0%(''('C/ 15,35$3 (;326(' C/15,3 5$3 5800INV/SS5800SS(;326(' C/15,3 5$3%$1. 31 C/$175$3(=2,'$/ 5,35$3/,1(' C+$11(/ 3 5 2 3  5 2: 3523/2' (0%(''('C/ 15,35$3 1         1  3 (;326(' C/15,3 5$3 C/$15,35$3 1 O;1 Z;1G ),1,6+*5$'((9(1 :,7+C8/9(57 ,19(57 C/15,35$3 C29(5(':,7+ 72362,/ /2:)/2:C8/9(576$1'5,35$372%( (0%(''('%(/2:1$785$/675($0 C+$11(/,19(57$7,1/(7$1'287/(7 1$785$/675($0%('0$7(5,$/0$< %(3/$C('%<7+(C2175$C72525 $//2:('72),//1$785$//< C/15,35$3 (;326('$/21* :,1*:$//6 ),/7(5)$%5,C /,1(5 1:1(;326(' 5,35$3%$1. 5,35$3'(7$,/)25,1/(7$1'287/(7 176 C/15,35$3  +($':$// C857$,1 :$// 1 /2:)/2:C+$11(/LEHIGH DR. 38%/,C 335 2 : 60 52 CL 59 86 CL 59 20 CL 58 51 CL 58 01 CL 57 48 CL 57 03 CL 56 85 CL5705 CL 57 09 CL 56 85 CL 55 85 CL 56 20 CL 56 03 CL 55 68 CL 54 89 CL 54 74 CL 54 29 CL 53 34 CL 53 36 CL 352326('  7(03 ,03$C7 352326('3 3(50$1(17,03$C7 3 5 2 3 5 2: 352352: 3 52 3 /2'352352$'C/3523/2';6(C;   6 ( C ;6 ( C;6(C 1  3  3                    3 3  3 3                    3 3  3                     3 3  3 3                   3  3                 3  3  3                 3  3    3 3                 3 3  3 3                33  3                   3  3  3  3                   3  3 3    3  31    3    3 3  3 TRASH RECEPTACLE AND PET WASTE STATION PARK AND PLAY TOT LOT(28'X20') TOT LOT ADA ACESS, SEE SHEET FOR 46 HC PARKING DETAIL 6/$% 16/$% 16/$% 136/$% 116/$% 16/$% 16/$% 1 6/$% 131 6/$% 1 6/$% 31 6/$% 1 6/$% 31 6/$%  6/$% 31 6/$%  6/$%  6/$% 36/$%  6/$% 6/$% 3 6/$% 316/$% 3 6/$% 33 6/$%  6/$% 1 6/$% 16/$% 1 6/$% 6/$% 1 6/$%  6/$% 6/$%  6/$% 6/$%  6/$% 6/$% 16/$% 16/$% 16/$% 16/$% 16/$% 16/$% 16/$% 16/$% 16/$% 16/$% 16/$% 16/$% 6/$% 1 6/$% 6/$% 1 6/$% 3 6/$% 3 6/$%  6/$% 3336/$% 31 6/$%  6/$% 31 6/$%  6/$% 36/$% 31 6/$%  6/$% 6/$% 3 6/$% 36/$%  6/$% 3 6/$% 1 6/$% 1 6/$% 6/$%  6/$% 6/$% 3 6/$% 3 6/$%  6/$% 3 6/$% 33 6/$% 1 6(16(1<9,//$*(3+, C216758C7(' 6(16(1<9,//$*( 3+,, 352326(' /(+,*+'5,9(7+25721:$< +23., 1 6 :$<*/(15,'*('55,9$11$3/ *$3581'5526680/$1(/( + , * +  ' 5 , 9 (/(+,*+'5,9(0(1$6+$C2857*/(15,'*('5352326(' 3+$6(,,/2'11:LQG\+LOO/DQH:LQFKHVWHU9LUJLQLD7HOHSKRQH:  1)D[:  ZZZJUHHQZD\HQJFRPFND1971ENGINEERING6+((72) '(6,*1('%<: ),/(12 6C$/(: '$7(:3528'/<6(59,1*9,5*,1,$ :(679,5*,1,$2)),C(6,1::,1C+(67(59$$6+%8519$ 0$57,16%85*:9$66+2:1 3/ 127(6: 1'(6,*1%$6('2186*6661<567250)25'(9(/230(172) '5$,1$*($5($ C8551(7/<1'(9/23('3(566 OUTLET RIP RAP EMBEDMENT DETAIL 6C$/(:1  INLET RIP RAP EMBEDMENT DETAIL 6C$/(:1  CULVERT PLAN VIEW 6C$/(:1  STREAM IMPACT DETAIL 6C$/(:1  VICINITY MAP/IMPACT MAP 6C$/(:1  CULVERT PROFILE VIEW 6C$/(:+ 1  9 1  C8/9(575('%8'0$*,67(5,$/',675,C7)5('(5,C.C2817<9,5*,1,$6(16(1<9,//$*(3+$6(,,3  1 =-.$6 1 5HY1R'DWH 3 11 HYDROLOGIC ANALYSIS 06Feb2026 149B 149E 149D149C C 3 2 1 66::LEHIGH DR. 38%/,C 331 11 1 13 13 52 :  75$,/(60772%( )5('(5,C.C2817<;;3: 1 3:1 3:1 3:1 3:1                00 59 LP 00 36 EP/LP 00 36 EP/LP 5800INV/SS5800SSC 7RS  ,Q  11 2XW 1 'HSWK 11 6'53#352326('  7(03 ,03$C7 352326('3 3(50$1(17,03$C7 3 5 2 3 5 2: 352352: 3 52 3 /2'352352$'C/3523/2':,1* :$//1 :,1* :$// :,1* :$// :,1* :$//3 1 11 1 13 13;6(C;   6 ( C ;6 ( C;6(C 1111              11              1111              1111             3523*5$'(%(+,1':$//3523*5$'(  ,1 )5217 2) :$//3523*5$'(%(+,1':$//3523*5$'(,1)52172):$//(;*5$'(3523*5$'(%(+,1':$//3523 *5$' (  ,1  )521 7 2 ) : $ / /(;*5$'(3523*5$'(%(+,1':$//3523*5$'(,1)52172):$//(;* 5 $ ' ( :,1*:$//1 +:1  9:1  :,1*:$// +:1  9:1  :,1*:$//3 +:1  9:1  :,1*:$// +:1  9:1  :,1*:$//72%( '(6,*1('%<27+(56 :,1*:$//72%( '(6,*1('%<27+(56  ; %2; C8/9(57  +($':$//  C857$,1:$// ( ;  * 5 $ ' (  ; %2; C8/9(57  +($':$//  C857$,1:$// :,1* :$// :,1* :$//1 %(*,1:,1*:$//1 (1':,1*:$// ; %2; C8/9(57  +($':$//  C857$,1:$// :,1* :$//  ; %2; C8/9(57  +($':$// :,1* :$//  C857$,1:$// :,1*:$//72%( '(6,*1('%<27+(56 :,1*:$//72%( '(6,*1('%<27+(56 1 (1':,1*:$//1 %(*,1:,1*:$//1 (1':,1*:$//13 (1':,1*:$//11 %(*,1:,1*:$//13 %(*,1:,1*:$//11:LQG\+LOO/DQH:LQFKHVWHU9LUJLQLD7HOHSKRQH:  1)D[:  ZZZJUHHQZD\HQJFRPFND1971ENGINEERING6+((72) '(6,*1('%<: ),/(12 6C$/(: '$7(:3528'/<6(59,1*9,5*,1,$ :(679,5*,1,$2)),C(6,1::,1C+(67(59$$6+%8519$ 0$57,16%85*:91$ 31 1 =-.$6  1 3/C8/9(57  5('%8'0$*,67(5,$/',675,C7)5('(5,C.C2817<9,5*,1,$6(16(1<9,//$*(3+$6(,,CULVERT PLAN VIEW 6C$/(:1   +($':$//72 %('(6,*1('%< 27+(56 127(:9'27'(7$,/63529,'('$6%$6,6)25C,9,/'(6,*16758C785$/'(6,*12) C8/9(5772%(3529,'('%<27+(56 5HY1R'DWH 1 1 06Feb2026 STORM PROFILE #EX149-#149D H: 1"=50'V: 1"=5' STORM PROFILE #149B-#149E H: 1"=50'V: 1"=5' EXISTING GRADE PROPOSED GRADE EXISTING GRADE 555 560 565 570 575 580 585 590 595 600 605 610 615 555 560 565 570 575 580 585 590 595 600 605 610 615 SAN XING565 570 575 580 585 590 595 600 605 610 615 565 570 575 580 585 590 595 600 605 610 615 SAN XINGSAN XING8" W/L XING8" W/L XING8" W/L XINGHGL HGL 149B 149E 0+00.00 = BaseINV OUT = 594.70INV IN = 594.95INV IN = 594.950+30.99 = BaseINV OUT = 595.97INV IN = 595.97TOP = 600.69DI-3B - 6'TOP = 600.69DI-3C - 6'-0+50 0+00 0+50 1+00 31' - 15" ADS N - 1 2 @ 3. 2 9 % 0+00 0+50 1+00 1+50 2+0040' - 15"ADS N-12 @ 10.00 % 80' - 15" ADS N- 1 2 @ 1.11% 26' - 15" ADS N-12 @ 0.53% 31' - 15" ADS N-1 2 @ 2.45 % EX 149 149A 149B 149C 149D 0+00.00 = BaseINV OUT = 579.53INV IN = 589.530+40.30 = BaseINV OUT = 593.56INV IN = 593.811+20.36 = BaseINV OUT = 594.70INV IN = 594.95INV IN = 594.951+46.72 = BaseINV OUT = 595.09INV IN = 595.341+77.74 = BaseINV OUT = 596.10INV IN = 596.10TOP = 602.69DI-2B - 6'TOP = 601.85DI-3B - 6'TOP = 600.69DI-3B - 6'TOP = 600.80DI-3B - 6'TOP = 600.81DI-3B - 6'2+50-0+50 PROPOSED GRADE EXISTING GRADE PROPOSED GRADE 10 11 12 13 14 15 16 17 18 19 20 21 TOP = 607.49TOP = 610.64DI-3C - 6'TOP = 610.67DI-3B - 6'TOP = 608.29TOP = 608.35DI-1TOP = 610.11DI-1TOP = 610.51DI-7 -TYPE IIITOP = 611.66DI-3ATOP = 611.64DI-3ATOP = 611.48DI-3ASTORM PROFILE #10-#21 H: 1"=50'V: 1"=5' -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 560 565 570 575 580 585 590 595 600 605 610 615 620 625 630 635 560 565 570 575 580 585 590 595 600 605 610 615 620 625 630 635 12' - 30" ADS N-12 @ 0.51% 92' - 30" ADS N-12 @ 0.50% 15' - 30" ADS N-12 @ 0.40% 95' - 30" ADS N-12 @ 0.40% 29' - 30" ADS N-12 @ 0.45% 174' - 30" ADS N-12 @ 0.50% 187' - 24" ADS N-12 @ 0.40% 110' - 24" ADS N-12 @ 0.40% 23' - 24" ADS N-12 @ 0.40% 25' - 24" ADS N-12 @ 0.40% 74' - 24" ADS N-12 @ 0.50%0+00.00 = EW-1 (30)INV OUT = 600.500+11.77 = MH 1 5'INV OUT = 600.56INV IN = 602.30INV IN = 603.801+03.69 = BASE 5'INV OUT = 602.76INV IN = 602.861+18.73 = BASE 6'INV OUT = 602.92INV IN = 603.022+13.34 = MH 1 5'INV OUT = 603.39INV IN = 603.492+42.42 = BASE 5'INV OUT = 603.62INV IN = 603.724+15.92 = BASE 5'INV OUT = 604.59INV IN = 605.09INV IN = 605.846+02.97 = BASE 5'INV OUT = 605.84INV IN = 605.94INV IN = 605.947+13.44 = BaseINV OUT = 606.38INV IN = 606.487+36.61 = BaseINV OUT = 606.58INV IN = 606.687+61.86 = BaseINV OUT = 606.78INV IN = 606.88INV IN = 607.258+36.36 = EW-1 (24) - INLETHGL CL A1 RIP RAP CL A1 RIP RAP 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV32 05/15/2025 ZJ, KAS ---- 51 3924L V: 1" = 5' H: 1" = 50'STORM SEWER PROFILESRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 01 07/01/2025 NOTES: 1.SAFETY SLAB AND STEEL PLATES TO BE PROVIDED PER VDOT ROAD & BRIDGE SPECIFICATIONS AND VDOT DRAINAGE MANUAL. 06Feb2026 PROPOSED GRADE EXISTING GRADE PROPOSED GRADE EXISTING GRADE EXISTING GRADE PROPOSED GRADE 71' - 12 " ADS N- 1 2 @ 2 . 7 7 % 16 16A 16B 0+00.00 = Base1+11.00 = BaseINV OUT = 608.52INV IN = 608.771+81.94 = BaseINV OUT = 610.73TOP = 610.11DI-1TOP = 612.52DI-3B - 6'TOP = 614.62DI-3B -12'32' - 24" ADS N-12 @ 0.50%8' - 24"ADS N-12 @ 11.28%17 17A 17B 0+00.00 = BaseINV OUT = 605.84INV IN = 605.94INV IN = 605.940+31.74 = BaseINV OUT = 606.10INV IN = 606.100+39.72 = EW-1 (24) - INLETINV IN = 607.00TOP = 610.51DI-7 -TYPE IIITOP = 609.89DI-7 -TYPE III15' - 24" ADS N-12 @ 0.50% 97' - 18" ADS N-12 @ 0.50% 59' - 18" ADS N-12 @ 0.50%88' - 15" ADS N-12 @ 9.42 % 131' - 1 5" A D S N- 1 2 @ 5. 2 7 % 111' - 15" ADS N-12 @ 0.50% 85' - 15" A D S N - 1 2 @ 2.44 % 94' - 1 2" A D S N- 1 2 @ 5.1 0 % 30 31 32 33 34 35 36 37 38 0+00.00 = EW-1 (24)INV OUT = 600.490+14.51 = MH1INV OUT = 600.57INV IN = 602.60INV IN = 604.071+11.99 = BaseINV OUT = 603.09INV IN = 603.191+70.86 = BaseINV OUT = 603.48INV IN = 603.832+59.19 = BaseINV OUT = 612.15INV IN = 612.653+90.15 = BaseINV OUT = 619.55INV IN = 619.805+01.15 = BaseINV OUT = 620.36INV IN = 620.615+86.48 = BaseINV OUT = 622.69INV IN = 622.946+80.64 = BaseINV OUT = 627.74TOP = 608.09TOP = 607.89DI-3B - 6'TOP = 607.98DI-3B - 6'TOP = 615.40DI-1TOP = 624.09DI-1TOP = 624.54DI-3B - 8'TOP = 626.86DI-3B - 6'TOP = 631.49DI-3C - 6'STORM PROFILE #16-#16B H: 1"=50'V: 1"=5' STORM PROFILE #17-#17B H: 1"=50'V: 1"=5' STORM PROFILE #30-#38 H: 1"=50'V: 1"=5' -0+50 0+00 0+50 1+00 1+50 2+00 2+50 575 580 585 590 595 600 605 610 615 620 625 575 580 585 590 595 600 605 610 615 620 625 -0+50 0+00 0+50 1+00 590 595 600 605 610 615 620 625 590 595 600 605 610 615 620 625 -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 585 590 595 600 605 610 615 620 625 630 635 640 645 650 655 660 665 585 590 595 600 605 610 615 620 625 630 635 640 645 650 655 660 665 SAN XINGSAN XING8" SAN XINGWL XINGWL XING8" WL XING4" SAN LOT XING - LOT 184" SAN LAT XING - LOT 171.5' MIN111' - 15 " A D S N - 1 2 @ 2 . 4 1 %INV OUT = 604.59INV IN = 605.84INV IN = 605.09HGL HGL HGL CL A1 RIP RAP CL A1 RIP RAP 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV33 05/15/2025 ZJ, KAS ---- 51 3924L V: 1" = 5' H: 1" = 50'STORM SEWER PROFILES (2)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 01 07/01/2025 NOTES: 1.SAFETY SLAB AND STEEL PLATES TO BE PROVIDED PER VDOT ROAD & BRIDGE SPECIFICATIONS AND VDOT DRAINAGE MANUAL. 06Feb2026 EXISTING GRADE PROPOSED GRADE 15' - 15" ADS N-12 @ 10.85% 26' - 15" ADS N-12 @ 2.88% 32' - 15" ADS N-12 @ 1.00% 53' - 1 2 " ADS N- 1 2 @ 4.6 4 % 31 Jellyfish 31A 31B 31C 0+00.00 = MH1INV OUT = 600.57INV IN = 604.07INV IN = 602.600+18.71 = FILTER (SEEDETAILS SHEET 25)INV OUT = 605.45INV IN = 605.950+49.02 = BaseINV OUT = 606.64INV IN = 606.740+81.12 = BaseINV OUT = 607.07INV IN = 607.321+33.97 = BaseINV OUT = 609.77TOP = 608.09TOP = 609.43TOP = 611.54DI-3B - 4'TOP = 611.40DI-3B - 8'TOP = 613.93DI-3B -12'STORM PROFILE #31-#31C H: 1"=50'V: 1"=5' -0+50 0+00 0+50 1+00 1+50 2+00 585 590 595 600 605 610 615 620 625 630 635 640 585 590 595 600 605 610 615 620 625 630 635 640 SAN XINGWL XINGHGL STORM PROFILE #11-#11A H: 1"=50'V: 1"=5' -0+50 580 585 590 595 600 605 610 615 620 625 580 585 590 595 600 605 610 615 620 625 11 11A 11B 8" SAN XING8" W/L XINGTOP = 612.09TOP = 607.49NYP-24DOMETOP = 610.00EXISTING GRADE 1.5' MINPROPOSED GRADE -0+50 0+00 0+50 1+00 1+50 86' - 12" ADS N-12 @ 0.75%0+00.00 = MH 1 5'INV OUT = 600.56INV IN = 603.80INV IN = 602.300+15.00 = NYP-18"INV OUT = 603.95INV IN = 604.051+01.41 = NYP-24"INV OUT = 604.70INV IN = 605.25 (6"UD)1.5' MIN15' - 12" ADS N-12 @ 1.00% BIORETENTION SEE SHEET 25HGL EXISTING GRADE PROPOSED GRADE 25' - 30" ADS N-12 @ 0.50% 70' - 24" ADS N-12 @ 2 . 0 1 % 41' - 24" ADS N-12 @ 2.00% 1 2 3 4 5 0+00.00 = EW-1 (30)INV OUT = 558.000+25.42 = MH1INV OUT = 558.13INV IN = 565.800+95.48 = MH1INV OUT = 567.20INV IN = 575.201+36.22 = MH1INV OUT = 576.02INV IN = 584.022+34.93 = SWM PRINCIPAL RISER WET POND 3, SEE SHEET 24TOP = 569.00TOP = 589.00TOP = 590.00TOP = 602.0060" RISERSTORM PROFILE #1-#5 H: 1"=50'V: 1"=5' -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 540 545 550 555 560 565 570 575 580 585 590 595 600 605 610 615 540 545 550 555 560 565 570 575 580 585 590 595 600 605 610 615 620 SEE SHEET 24 FOR OUTFALL PI P E A N D R I S E R DETAILS HGL CL A1 RIP RAP E 620 DRAINAGE BLANKET TO DAYLIGHT, SEE DETAIL SHEET 24 CONCRETE CRADLE, SEE DETAIL SHEET 24 CL A1 RIP RAP AND FLOW SPREADER SEE DETAIL SHEET 25 14' - 15" ADS N-12 @ 0.55% 70' - 1 2 " ADS N - 1 2 @ 3 . 7 1 % 125' - 1 2" A D S N- 1 2 @ 5. 8 5 % 40 41 42 43 0+00.00 = EW-1 (15)INV OUT = 609.500+14.26 = BaseINV OUT = 609.58INV IN = 609.830+84.73 = BaseINV OUT = 612.44INV IN = 612.692+09.78 = BaseINV OUT = 620.01TOP = 612.57DI-1TOP = 614.84DI-1TOP = 623.64DI-3B - 8'STORM PROFILE #40-#43 H: 1"=50'V: 1"=5' -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 590 595 600 605 610 615 620 625 630 635 640 645 590 595 600 605 610 615 620 625 630 635 640 645 HGL 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV34 05/15/2025 ZJ, KAS ---- 51 3924L V: 1" = 5' H: 1" = 50'STORM SEWER PROFILES (3)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 01 07/01/2025 NOTES: 1.SAFETY SLAB AND STEEL PLATES TO BE PROVIDED PER VDOT ROAD & BRIDGE SPECIFICATIONS AND VDOT DRAINAGE MANUAL. 06Feb2026 27' - 8" CL-52 DIP @12.28%COMPACT FILL PER GEOTECHNICAL REPORT COMPACT FILL PER GEOTECHNICAL REPORT EXISTING GRADE PROPOSED GRADE SANITARY PROFILE EX BB-J H: 1"=50'V: 1"=5' 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 22+50 23+00 23+50 24+00 555 560 565 570 575 580 585 590 595 600 605 610 615 620 625 630 635 640 645 555 560 565 570 575 580 585 590 595 600 605 610 615 620 625 630 635 640 645 EX BB A B C D E F 10+00.00= EX BBEX INV OUT=580.00EX INV IN=580.2010+27.12=AINV OUT=583.53INV IN=583.7311+32.02=BINV OUT=591.60INV IN=591.8012+87.69=CINV OUT=594.91INV IN=595.1114+47.39=DINV OUT=600.38INV IN=600.5815+69.91=EINV OUT=601.31INV IN=601.51INV IN=601.5116+51.93=FINV OUT=601.92INV IN=602.12TOP=606.74TOP=604.22TOP=600.84TOP=602.72TOP=609.76TOP=612.72TOP=610.85TOP=613.93TOP=631.3915" STORM XING12" STORM XING12" STORM XINGTRIPLE BOX CULVERT18" STORM XING15" STORM XING6" W/L XING12" STORM XING12" STORM XING8" W/L XING1.5' MIN105' - 8" CL-5 2 DI P @7.5 0 %1.5' MIN1.5' MINRESTRAINT JOINTS (TYP.) RESTRAINT JOINTS (TYP.) 1.5' MIN 0+17 = LOT 30 - 30'@20.00% INV@END=608.33123' - 8" SDR 35/26 @0.60% 160' - 8 " S D R 3 5 / 2 6 @ 3 . 3 0 % 156' - 8" S D R 3 5 / 2 6 @2.00% 82' - 8" SDR 35/26 @0.50%CONTRACTOR TO CORE DRILL AND RESHAPE INVERTCONTRACTOR TO FIELD VERIFY INVERTS AND LOCATIONG TOP = 610.477+33.28 = BaseINV OUT = 602.53INV IN (8") = 602.731+42 = LOT 71 - 20'@19.54% INV@END=608.201+22 = LOT 72 - 20'@19.26% INV@END=608.061+02 = LOT 73 - 21'@19.03% INV@END=607.930+82 = LOT 74 - 21'@18.76% INV@END=607.790+62 = LOT 75 - 21'@18.49% INV@END=607.650+42 = LOT 76 - 21'@18.27% INV@END=607.520+19 = LOT 77 - 21'@16.15% INV@END=606.980+00 = LOT 78 - 17'@21.82% INV@END=606.6681' - 8" SDR 35/26 @ 0.50% 182' - 8" SDR 35/26 @ 0.50% H 9+15.43 = BaseINV OUT = 603.64INV IN (8") = 603.84INV IN (8") = 603.84TOP = 612.430+00 = LOT 70 - 18'@26.59% INV@END=608.53I 9+68.19 = BaseINV OUT = 606.48INV IN (8") = 606.6853' - 8" SDR 3 5/ 2 6 @ 5.0 0 %0+46 = LOT 31 - 21'@12.00% INV@END=611.980+76 = LOT 32 - 21'@12.00% INV@END=613.340+96 = LOT 33 - 21'@10.00% INV@END=613.831+16 = LOT 34 - 21'@10.00% INV@END=614.731+36 = LOT 35 - 21'@10.00% INV@END=615.631+56 = LOT 36 - 21'@12.00% INV@END=616.951+76 = LOT 37 - 21'@12.00% INV@END=617.851+96 = LOT 38 - 21'@12.00% INV@END=618.752+35 = LOT 39 - 21'@11.99% INV@END=620.502+65 = LOT 40 - 21'@14.00% INV@END=622.282+85 = LOT 41 - 21'@14.00% INV@END=623.183+05 = LOT 42 - 21'@14.00% INV@END=624.083+25 = LOT 43 - 21'@14.00% INV@END=624.983+45 = LOT 44 - 21'@14.00% INV@END=625.893+65 = LOT 45 - 21'@16.00% INV@END=627.200+00 = LOT 46 - 19'@18.84% INV@END=627.523+29 = LOT 47 - 32'@4.00% INV@END=623.553+09 = LOT 48 - 32'@4.00% INV@END=622.642+89 = LOT 49 - 32'@4.00% INV@END=621.742+69 = LOT 50 - 32'@4.00% INV@END=620.842+49 = LOT 51 - 32'@3.02% INV@END=619.622+29 = LOT 52 - 32'@3.02% INV@END=618.722+06 = LOT 53 - 32'@3.02% INV@END=617.661+83 = LOT 54 - 32'@3.02% INV@END=616.621+42 = LOT 55 - 32'@2.51% INV@END=614.641+22 = LOT 56 - 32'@2.51% INV@END=613.731+02 = LOT 57 - 32'@2.00% INV@END=612.670+82 = LOT 58 - 32'@2.00% INV@END=611.770+62 = LOT 59 - 32'@2.00% INV@END=610.870+42 = LOT 60 - 32'@2.00% INV@END=609.960+19 = LOT 61 - 32'@2.00% INV@END=608.90J 13+38.56 = BaseINV OUT = 623.39INV IN (8") = 623.39370' - 8 " S D R 3 5/ 2 6 @ 4. 5 1 %0+00 = LOT 62 - 29'@6.74% INV@END=608.97INV IN (4") = 603.06INV IN (4") = 604.17INV IN (4") = 623.92INV IN (4") = 607.01APPROX LCOATION EX. 24" STORM XINGINV IN=580.20FREDERICK WATER'S PORTION OF SEWER LATERALS SHALL ALSO BE RESTRAINED IN FILL FREDERICK WATER'S PORTION OF SEWER LATERALS SHALL ALSO BE RESTRAINED IN FILL 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV35 05/15/2025 ZJ, KAS ---- 51 3924LSCALE: 1" = 5'50510SCALE: 1" = 50' 50 25 0 50 100 V: 1" = 5' H: 1" = 50'SANITARY SEWER PROFILESRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 02 07/31/2025 06Feb2026 9+50 10+00 10+50 11+00 11+50 12+00 585 590 595 600 605 610 615 620 585 590 595 600 605 610 615 620H K 10+00.00=HINV OUT=603.64INV IN=603.8411+50.17=KINV OUT=604.59TOP=612.43TOP=611.59580 580 575 575 SANITARY PROFILE H-K H: 1"=50'V: 1"=5' EXISTING GRADE COMPACT FILL PER GEOTECHNICAL REPORT PROPOSED GRADE 0+00 = LOT 63 - 19'@14.84% INV@END=607.901+23 = LOT 64 - 20'@13.99% INV@END=608.061+03 = LOT 65 - 20'@16.02% INV@END=608.370+83 = LOT 66 - 20'@18.01% INV@END=608.670+63 = LOT 67 - 20'@18.00% INV@END=608.560+43 = LOT 68 - 20'@20.00% INV@END=608.860+23 = LOT 69 - 20'@19.99% INV@END=608.750+00 = LOT 70 - 18'@26.59% INV@END=608.53150' - 8" SDR 35/26 @0.50%INV IN (4")=604.17INV IN (4")=605.12RESTRAINT JOINTS (TYP.) FREDERICK WATER'S PORTION OF SEWER LATERALS SHALL ALSO BE RESTRAINED IN FILL 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 580 585 590 595 600 605 610 615 620 625 630 635 640 645 580 585 590 595 600 605 610 615 620 625 630 635 640 645 E L 10+00.00=EINV OUT=601.31INV IN=601.51INV IN=601.5114+00.01=LINV OUT=620.58TOP=612.72TOP=627.838" W/L XING15" STORM XINGSANITARY PROFILE E-L H: 1"=50'V: 1"=5' 575 575 570 570 EXISTING GRADE PROPOSED GRADE 0+84 = LOT 1 - 20'@27.32% INV@END=611.601+14 = LOT 2 - 20'@27.82% INV@END=613.121+35 = LOT 3 - 20'@30.20% INV@END=614.621+54 = LOT 4 - 20'@29.95% INV@END=615.521+74 = LOT 5 - 20'@29.99% INV@END=616.491+94 = LOT 6 - 20'@30.01% INV@END=617.452+14 = LOT 7 - 20'@30.02% INV@END=618.412+34 = LOT 8 - 20'@33.02% INV@END=619.972+69 = LOT 9 - 20'@28.01% INV@END=620.632+92 = LOT 10 - 20'@25.00% INV@END=621.133+15 = LOT 11 - 20'@21.99% INV@END=621.673+35 = LOT 12 - 20'@20.01% INV@END=622.233+55 = LOT 13 - 20'@16.02% INV@END=622.403+75 = LOT 14 - 20'@13.99% INV@END=622.953+95 = LOT 15 - 20'@12.02% INV@END=623.510+00 = LOT 16 - 19'@14.43% INV@END=623.812+73 = LOT 17 - 32'@15.00% INV@END=620.102+63 = LOT 18 - 32'@15.00% INV@END=619.622+43 = LOT 19 - 32'@17.01% INV@END=619.312+23 = LOT 20 - 32'@17.00% INV@END=618.362+03 = LOT 21 - 32'@16.99% INV@END=617.411+79 = LOT 22 - 32'@17.00%INV@END=616.301+56 = LOT 23 - 32'@16.99%INV@END=615.191+16 = LOT 24 - 32'@14.99%INV@END=612.630+96 = LOT 25 - 32'@15.01% INV@END=611.690+76 = LOT 26 - 32'@14.01% INV@END=610.410+56 = LOT 27 - 32'@14.00% INV@END=609.460+36 = LOT 28 - 32'@15.00% INV@END=608.840+16 = LOT 29 - 32'@16.99% INV@END=608.53400' - 8 " S D R 3 5/ 2 6 @ 4. 7 7 %INV IN (4")=621.11151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV36 05/15/2025 ZJ, KAS ---- 51 3924L V: 1" = 5' H: 1" = 50'SCALE: 1" = 5'50510SCALE: 1" = 50' 50 25 0 50 100 SANITARY SEWER PROFILES (2)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 02 07/31/2025 06Feb2026 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 555 560 565 570 575 580 585 590 595 600 605 610 615 620 555 560 565 570 575 580 585 590 595 600 605 610 615 620 8" SAN XING10+00 = EX W/L (PHASE 1)8"x8" TEE, 3-8" GV15+96.51 = 00+00.00 W/L "B"12"x8" TEE, 1-12" GV, 2-8" GVRESTRAINT JOINTS (TYP.) COMPACT FILL PER GEOTECHNICAL REPORT EXISTING GRADE 4' MIN4' MINWATER LINE "A" PROFILE (LEHIGH DR.) H: 1"=50'V: 1"=5'1.5' MIN1.5' MINPROPOSED GRADE 4' MIN12 " W / L D I P C L 5 2 12 " W/L D I P C L 5 2 12 " W/L D I P C L 5 2 15" STM XING12" STM XING12" STM XING18" STM XING15" STM XINGTRIPLE BOX CULVERTEXISTING GRADE EXISTING GRADE 10+02 = 8"x12" REDUCER151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV37 05/15/2025 ZJ, KAS ---- 51 3924LSCALE: 1" = 5'50510SCALE: 1" = 50' 50 25 0 50 100 V: 1" = 5' H: 1" = 50'WATER LINE PROFILESRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 02 07/31/2025 NOTES: 1.VALVES, MANHOLES, ARV'S AND OTHER FREDERICK WATER SURFACE FEATURES SHALL NOT BE PLACED IN CURB AND GUTTER, NOR SLOPED PORTIONS OF HANDICAPPED RAMPS. CONTRACTOR SHALL COORDINATE LOCATIONS WITH THE FREDERICK WATER INSPECTOR. 2.IRRIGATION LINES AND DEVICES, LIGHT POLES, TRANSFORMERS, JUNCTION BOXES, PEDESTALS, OTHER OBSTACLES AND ALL DRY UTILITIES SHALL NOT BE PLACED ON FREDERICK WATER EASEMENTS. PERPENDICULAR IRRIGATION LINES, AND DRY UTILITY CROSSINGS ARE PERMITTED WITH 18" MINIMUM VERTICAL SEPARATION. 3.RETAINING WALLS AND THEIR TIE BACKS SUCH AS GEO GRID OR OTHER SUPPORTS SHALL NOT BE PLACED IN FREDERICK WATER EASEMENTS. 4.CONTRACTOR SHALL PROVIDE ONE KENNEDY I HYDRANT OR MUELLER SUPER CENTURION WITH HYDRO-GUARD FOR REMOTE PRESSURE AND TEMPERATURE MONITORING. THE DEVELOPER OR HIS/HER AGENT SHALL PROCURE A TWO-YEAR MONITORING CONTRACT FOR THE MONITORING SERVICE AND TELEMETRY AND PROVIDE ACCESS TO FREDERICK WATER ONCE THE SUBSCRIPTION IS ACTIVE. THE FREDERICK WATER INSPECTOR SHALL CHOOSE WHICH OF THE REQUIRED HYDRANTS SHALL BE A KENNEDY I HYDRANT OR MUELLER SUPER CENTURION EACH RESIDENTIAL SITE PLAN. 06Feb2026 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 585 590 595 600 605 610 615 620 625 630 635 640 645 650 585 590 595 600 605 610 615 620 625 630 635 640 645 650 8" SAN XING4" SAN LAT XING - LOT 304" SAN LAT XING - LOT 294" SAN LAT XING - LOT 284" SAN LAT XING - LOT 274" SAN LAT XING - LOT 264" SAN LAT XING - LOT 254" SAN LAT XING - LOT 244" SAN LAT XING - LOT 234" SAN LAT XING - LOT 224" SAN LAT XING - LOT 214" SAN LAT XING - LOT 204" SAN LAT XING - LOT 194" SAN LAT XING - LOT 184" SAN LAT XING - LOT 1710+00 = 1-6" GV,FH ASSEMBLYWATER LINE "B" PROFILE (RIVANNA PL.) H: 1"=50'V: 1"=5'19+20.55 =8"x6" FH ASSEMBLY11+85.90 = 8"x6" TEE,1-6" GV, FH ASSEMBLY16+17.48 = 8"x6" TEE,1-6" GV, FH ASSEMBLYRESTRAINT JOINTS (TYP.) 8" W/L DIP CL 5 2 8" W/ L DI P C L 5 2 8" W/L DIP C L 5 2 11+26.98 = 10+00 W/L "C"8"x8" TEE, 3-8" GV18+10.31 = 17+34.81 W/L "C"8"x8" TEE, 3-8" GVCOMPACT FILL PER GEOTECHNICAL REPORT4' MIN4' MIN4' MIN1.5' MIN1.5' MIN1.5' MIN1.5' MIN1.5' MINEXISTING GRADE PROPOSED GRADE12" STM XING15" STM XING10+09.81 =8"x6" REDUCER19+11.54 = 1-6" GV19+07.60 = 8"x6" REDUCER12" STM XING151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV38 05/15/2025 ZJ, KAS ---- 51 3924LSCALE: 1" = 5'50510SCALE: 1" = 50' 50 25 0 50 100 V: 1" = 5' H: 1" = 50'WATER LINE PROFILES (2)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 02 07/31/2025 NOTES: 1.VALVES, MANHOLES, ARV'S AND OTHER FREDERICK WATER SURFACE FEATURES SHALL NOT BE PLACED IN CURB AND GUTTER, NOR SLOPED PORTIONS OF HANDICAPPED RAMPS. CONTRACTOR SHALL COORDINATE LOCATIONS WITH THE FREDERICK WATER INSPECTOR. 2.IRRIGATION LINES AND DEVICES, LIGHT POLES, TRANSFORMERS, JUNCTION BOXES, PEDESTALS, OTHER OBSTACLES AND ALL DRY UTILITIES SHALL NOT BE PLACED ON FREDERICK WATER EASEMENTS. PERPENDICULAR IRRIGATION LINES, AND DRY UTILITY CROSSINGS ARE PERMITTED WITH 18" MINIMUM VERTICAL SEPARATION. 3.RETAINING WALLS AND THEIR TIE BACKS SUCH AS GEO GRID OR OTHER SUPPORTS SHALL NOT BE PLACED IN FREDERICK WATER EASEMENTS. 4.CONTRACTOR SHALL PROVIDE ONE KENNEDY I HYDRANT OR MUELLER SUPER CENTURION WITH HYDRO-GUARD FOR REMOTE PRESSURE AND TEMPERATURE MONITORING. THE DEVELOPER OR HIS/HER AGENT SHALL PROCURE A TWO-YEAR MONITORING CONTRACT FOR THE MONITORING SERVICE AND TELEMETRY AND PROVIDE ACCESS TO FREDERICK WATER ONCE THE SUBSCRIPTION IS ACTIVE. THE FREDERICK WATER INSPECTOR SHALL CHOOSE WHICH OF THE REQUIRED HYDRANTS SHALL BE A KENNEDY I HYDRANT OR MUELLER SUPER CENTURION EACH RESIDENTIAL SITE PLAN. 06Feb2026 WATER LINE "C" PROFILE (GAP RUN DR.) H: 1"=50'V: 1"=5' 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 585 590 595 600 605 610 615 620 625 630 635 640 645 650 585 590 595 600 605 610 615 620 625 630 635 640 645 650 10+00 = 11+17.54 W/L "B"8"x8" TEE, 3-8" GV17+34.81 = 18+00.87 W/L "B"8"x8" TEE, 3-8" GV12+03.94 = 8"x6" TEE,1-6" GV, FH ASSEMBLYRESTRAINT JOINTS (TYP.)4" SAN LAT XING - LOT 624" SAN LAT XING - LOT 614" SAN LAT XING - LOT 604" SAN LAT XING - LOT 594" SAN LAT XING - LOT 584" SAN LAT XING - LOT 574" SAN LAT XING - LOT 564" SAN LAT XING - LOT 554" SAN LAT XING - LOT 544" SAN LAT XING - LOT 534" SAN LAT XING - LOT 524" SAN LAT XING - LOT 514" SAN LAT XING - LOT 504" SAN LAT XING - LOT 494" SAN LAT XING - LOT 484" SAN LAT XING - LOT 478" W/L D I P C L 5 2 15+06.69= AIR RELEASE VACUUM VALVE14+69.22 = 8"x6" TEE,1-6" GV, FH ASSEMBLY8" W/ L DI P C L 5 2 8" W/L D I P C L 5 2 COMPACT FILL PER GEOTECHNICAL REPORT 1.5' MIN1.5' MIN1.5' MIN4' MIN4' MIN4' MINEXISTING GRADE PROPOSED GRADE 14+24.48 = 10+00 WL "D"8" TEE, 3 8" GV9+50 10+00 10+50 11+00 615 620 625 630 635 640 645 650 615 620 625 630 635 640 645 650 WATER LINE "D" PROFILE (STUB) H: 1"=50'V: 1"=5'10+00 = 11+17.54 W/L "B"8"x8" TEE, 3-8" GV4' MIN10+36.24 = 1-8" GV, 8"STUB W/FLUSHING ASSYA 25' PREBLAST ZONE SHALL BE REQUIRED FOR FUTURE CONNECTIONS AS NEEDED PER FREDERICK WATER'S INSPECTOR 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WV39 05/15/2025 ZJ, KAS ---- 51 3924LSCALE: 1" = 5'50510SCALE: 1" = 50' 50 25 0 50 100 V: 1" = 5' H: 1" = 50'WATER LINE PROFILES (3)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 02 07/31/2025 NOTES: 1.VALVES, MANHOLES, ARV'S AND OTHER FREDERICK WATER SURFACE FEATURES SHALL NOT BE PLACED IN CURB AND GUTTER, NOR SLOPED PORTIONS OF HANDICAPPED RAMPS. CONTRACTOR SHALL COORDINATE LOCATIONS WITH THE FREDERICK WATER INSPECTOR. 2.IRRIGATION LINES AND DEVICES, LIGHT POLES, TRANSFORMERS, JUNCTION BOXES, PEDESTALS, OTHER OBSTACLES AND ALL DRY UTILITIES SHALL NOT BE PLACED ON FREDERICK WATER EASEMENTS. PERPENDICULAR IRRIGATION LINES, AND DRY UTILITY CROSSINGS ARE PERMITTED WITH 18" MINIMUM VERTICAL SEPARATION. 3.RETAINING WALLS AND THEIR TIE BACKS SUCH AS GEO GRID OR OTHER SUPPORTS SHALL NOT BE PLACED IN FREDERICK WATER EASEMENTS. 4.CONTRACTOR SHALL PROVIDE ONE KENNEDY I HYDRANT OR MUELLER SUPER CENTURION WITH HYDRO-GUARD FOR REMOTE PRESSURE AND TEMPERATURE MONITORING. THE DEVELOPER OR HIS/HER AGENT SHALL PROCURE A TWO-YEAR MONITORING CONTRACT FOR THE MONITORING SERVICE AND TELEMETRY AND PROVIDE ACCESS TO FREDERICK WATER ONCE THE SUBSCRIPTION IS ACTIVE. THE FREDERICK WATER INSPECTOR SHALL CHOOSE WHICH OF THE REQUIRED HYDRANTS SHALL BE A KENNEDY I HYDRANT OR MUELLER SUPER CENTURION EACH RESIDENTIAL SITE PLAN. 06Feb2026 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVN/A 40 05/15/2025 ZJ, KAS ---- 51 3924LSTORM SEWER COMPUTATIONSRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 06Feb2026 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVN/A 41 05/15/2025 ZJ, KAS ---- 51 3924LLuL d Lu = up bend restrained lengthof pipe (PVC or DIP) up bend depth depth 4 ft. min. down bend Ld = down bend restrained length of pipe (PVC or DIP) finished grade Lu Ld -4- VERTICAL OFFSET RESTRAINED JOINTS FOR 45° Ld (ft) 20 40 60 80 Lu (ft) 20 20 20 20 Each side of any vertical offset bend shall be restrained. In addition, any joint that falls within the specified length on each side of the fitting shall be restrained. D 6" 8" & 12" 16", 18" & 20" 24" 22 1/2° Ld (ft) 20 20 40 40 Lu (ft) 20 20 20 20 D 6" 8" & 12" 16", 18" & 20" 24" 11 1/4° Ld (ft) 20 20 20 20 Lu (ft) 20 20 20 20 D 6" 8" & 12" 16", 18" & 20" 24" D D = pipe diameter FEB 09 48" min. 6" stone valve restrained to main 6", 8" and 12" 16", 18", 20" and 24" screw type adjustable valve box 8"x 8"x 16" solid block 60" min. over-excavation 18" to 24" concrete pad 18" dia. x 6" deep finished grade concrete pad 18" dia. x 6" deep finished grade Water Forced Sewer 24" min. screw type adjustable valve box Note: valve shall be spur gear type 6" stone 8"x 8"x 16" solid block valve restrained to main screw type adjustable valve box concrete pad 18" dia. x 6" deep 8"x 8"x 16" solid block for 12" valve Note: valve shall be bevel gear type GATE VALVE stone joint restraintsstone valve restrained to main 48" min. 6" stone location marker -5- APR 09 valve box adaptor valve box adaptor valve box adaptor 6" exterior of all sections to have waterproof coating 3/4" x 2" butyl joint sealant 24" min. in undeveloped areas square skid pad 6" thick around manhole frame in developed areas finished grade finished grade 3/4" concrete anchor bolts (4 each) STANDARD MANHOLE adjustment rings (11" max.) steel reinforced polypropylene steps 24" min. clear opening 6. There shall be a 0.20 foot drop in elevation through the manhole. 3/4 dia. 6" stone 1'-6" 35" max. 12" or 16" (typ.) 6" stone 4'-0" variable 3'-0" min. 4'-0" max. 8" 1. Manhole sections shall have an external coating of approved polymer film water proofing prior to installation. 2. If adjustment elevation exceeds two inches use concrete adjustment rings with a exterior coating of water proofing. 3. Final slope adjustment of manhole frame shall be by shims and non-shrink grout. 4. Skid pad to be placed around manholes located in shoulders of roads. 5. Flat top shall be used if height from invert out to rim is four feet or less. Frame to be 4" in height. NOTES : 5"pipe to manhole connection to be by flexible sleeve top of bench to be same elevation as top of pipe 1" nominal size butyl joint sealant to be applied on lower ledge of joint top of manhole at grade in pavement areas unless otherwise directed (top shall be set 24" min. above grade in undeveloped areas) invert channel to provide a smooth transition in to out, for all connections precast invert or grout bottom to form channel joint gasket shall be either o-ring or profile concrete ASTMC-150 4000 psi 2'-0" max. -15- FEB 09 18" 3' minimum PL 2' treated 2"x 4" with top 6" painted green 4" pipe at 2.00% minimum grade 36" min. cover property line solvent weld cap8" x 4" gasketed bell wye spigot by gasketed bell 45° bend location marker 5' stone grade finished 45° GRAVITY SEWER LATERAL FOR MAIN WITH COVER 15 FT OR LESS gasketed pipe and fittings All pipe and fittings shall be SDR 35/26 . -22- FEB 09 Both joints of the fitting shall be restrained. In addition, all joints within the specified length on the large side of the reducer shall be restrained. REDUCER L L (ft) 60 60 100 120 120 140 160 D 6" 8" 12" 16" 18" 20" 24" L falls within the specified length shall be restrained. In addition to restraining the connection, any joint that VALVE, DEAD END L 8" 12" 16" 18" 20" 24" 8" -- 60 80 100 120 140 D1 12" -- -- 60 80 100 120 16" -- -- -- 40 60 100 18" -- -- -- -- 40 80 20" -- -- -- -- -- 60 -3- GATE VALVE AND DEAD END RESTRAINED JOINTS FOR REDUCER, 6" 40 60 100 120 120 140 D2D1 L D L = restrained length of D = pipe diameter pipe (PVC or DIP) L (ft) D2 L = restrained length of D = pipe diameter pipe (PVC or DIP) FEB 09 L = restrained length of pipe (PVC or DIP) HORIZONTAL BEND 45°, 22 1/2°, 11 1/4° D 6" 8" 12" 16" 18" 20" 24" L (ft) 20 20 20 20 20 20 20 L TEE, CROSS, WYE any joint that falls within the specified length of each branch of the fitting shall be restrained. In addition to restraining each joint of the fitting, D = pipe diameter L LL L-2- TEE, CROSS, WYE AND HORIZONTAL BEND RESTRAINED JOINTS FOR D 6" 8" 12" 16" 18" 20" 24" L (ft) 60 60 100 120 120 140 160 DD D L = restrained length of pipe (PVC or DIP) D = pipe diameter FEB 09 FREDERICK WATER DETAILSRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 02 07/31/2025 06Feb2026 N/A A // =-.A6   /:LQG\+LOO/DQH:LQFKHVWHU9LUJLQLD7HOHSKRQH  )D[  ZZZJUHHQZD\HQJFRPFND1971ENGINEERING6+((72) '(6,*N('%< ),/(N2 6&A/( 'A7(3528'/<6(59,N*9,5*,N,A :(679,5*,N,A2)),&(6,N:,N&+(67(59AA6+%85N9A 0A57,N6%85*:9:A7(502'(/5('%8'0A*,67(5,A/',675,&7)5('(5,&.&28N7<9,5*,N,A6(N6(N<9,//A*(3+A6(,,5HYNR'DWH // 06Feb2026 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVN/A 42 05/15/2025 ZJ, KAS ---- 51 3924LVDOT DETAILSRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 02 07/31/2025 06Feb2026 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVN/A 43 05/15/2025 ZJ, KAS ---- 51 3924LVDOT DETAILS (2)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 04 02/06/2024 06Feb2026 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVN/A 44 05/15/2025 ZJ, KAS ---- 51 3924L SQUARE TUBE STEEL SIGN POSTS - Square tube steel sign posts shall be fabricated from hot rolled. carbon sheet steel, structural steel quality, conforming to the requirements of ASTM A1011, grade 50 except the yield strength after cool forming shall be 60,000 psi minimum. The steel gauge shall be 14 gauge for the 2 inch by 2 inch post and 10 gauge for the 2 1/2 inch by 2 1/2 inch posts. Posts (inside and outside) shall be galvanized in accordance with the requirements of ASTM A653. Coating Designation G-90. Post shall use an in ground anchor system that provides a stable installation and allows easy replacement of the sign post into the anchor system after vehicular impact. Post shall conform to the breakaway requirements of AASHTO's Standard Specifications for Structural Supports for Highway Signs, Luminaries, and Traffic Signals (1994 Edition including revisions). The Contractor shall provide a copy of the FHWA's acceptance letter indicating compliance with breakaway requirements at the time of catalog submission of the posts. Posts shall have 7/16 inch (+/- 1/64 inch) openings or knockouts spaced 1 inch on centers on all four sides. Post shall be installed in accordance with the manufacturer's recommendations.VDOT DETAILS (3)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 02 07/31/2025 06Feb2026 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVN/A 45 05/15/2025 ZJ, KAS ---- 51 3924LVDOT DETAILS (4)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IIRev. No.Date 02 07/31/2025 06Feb2026 PROPOSED GRADE EXISTING GRADE RET WALL #1 H: 1"=50'V: 1"=5' 9+50 10+00 10+50 11+00 11+50630 635 640 645 650 655 660 630 635 640 645 650 655 660 PROPOSED GRADE EXISTING GRADE RET WALL #2 H: 1"=50'V: 1"=5' 9+50 10+00 10+50 11+00 11+50615 620 625 630 615 620 625 630 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVN/A 46 05/15/2025 ZJ, KAS ---- 51 3924LNOTES: 1. RECREATIONAL UNITS BASED ON SIMILAR PLAYGROUND. CONTRACTOR TO CONFIRM WITH FREDERICK COUNTY PARKS & RECREATION PRIOR TO CONSTRUCTION. 2. THE TOTAL RECREATION UNITS FOR PHASE II MUST MEET OR EXCEED THE TOTAL VALUE OF $36,059.98. 3. BENCHES MUST ALSO BE PROVIDED AT EACH RECREATIONAL UNIT. 4. THE CONTRACTOR SHALL ENSURE THE PLAYGROUNDS CONFORM TO THE SPECIFICATIONS IN §165-806 OF THE FREDERICK COUNTY CODE PRIOR TO CONSTRUCTION.DETAILSRED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIASENSENY VILLAGEPHASE IINOTES: 1. RETAINING WALLS TO BE DESIGNED BY OTHERS DRIVEWAY APRON FOR DRIVEWAYS ON PRIVATE STREETS WITH CG-6 Rev. No.Date 06 06/29/2026 8' MIN.18' OR 20'STRIPED AREA HANDICAPPED SYMBOLS FC EP 4.0' MIN. 7.0' MAX. 4" STEEL PIPE FILLED WITH CONCRETE DISPLAY CONDITIONS 24" 6"6" 9" RESERVED PARKING 12" 2' SIGN (SEE DETAIL) HANDICAPPED PARKING N.T.S. 04/15 VER 1 NOTE: RAMP FOR HANDICAPPED MUST BE LOCATED AT SAME POINT ADJACENT TO THE STRIPED AISLE. LIGHT COLORED REFLECTIVE BACKGROUND MAT'L. DARK COLORED 2" LETTERS & 3/8" BORDER INTERNATIONAL SYMBOL OF ACCESSIBILITY PENALTY, $100-$500 FINE, TOW-AWAY ZONE LIGHT COLORED 1" LETTERS DARK COLORED REFLECTIVE BACKGROUND MATERIAL SIGN SHALL BE LOCATED SUCH THAT IT WILL NOT BE OBSCURED BY VEHICLE PARKED IN SPACE. 8' VAN ACCESSIBLE SPACE 5' FOR REGULAR SPACE WHEEL STOP 29Jun2026 RIVANNA PL. GAP RUN DR.RIVANNA PL.LEHIGH DR.2' 2' 100' 2' 2'2' 2'2'2'2'2'2'2'2' SIGN 7<PE "A" SIGN 7<PE "D" E;. )IRE H<DRAN7 )IRE H<DRAN7 )IRE H<DRAN7 )IRE H<DRAN7 )IRE H<DRAN7 )IRE H<DRAN7 )IRE H<DRAN7 )IRE H<DRAN7 SIGN 7<PE "D" SIGN 7<PE "D" SIGN 7<PE "02DI)IED D" SIGN 7<PE "02DI)IED D" SIGN 7<PE "C" SIGN 7<PE "D" SIGN 7<PE "A" SIGN 7<PE "02DI)IED D" SIGN 7<PE "02DI)IED D" SIGN 7<PE "C" SIGN 7<PE "A" SIGN 7<PE "C" SIGN 7<PE "A" SIGN 7<PE "D" SIGN 7<PE "02DI)IED D" SIGN 7<PE "02DI)IED D" SIGN 7<PE "02DI)IED D"SIGN 7<PE "02DI)IED D" SIGN 7<PE "02DI)IED D" SIGN 7<PE "02DI)IED D"GRID 0ERIDIANVA N2R7H =2NE NADL27 2 L27 1 L27 2 L27 0 L27  L27  L27  L27 1 L27 1L27 2 L27 1 L27 2 L27  L27  L27 5 L27  L27  L27  L27  L27 L27 0 L27 1 L27 2 L27  L27  L27 5 L27 2L27 2 L27 2 L27 2 L27 25 L27 1L27 2 L27 22 L27 21 L27 20 L27 1 L27 1 L27  L27  L27 1L27  L27  L27 5 L27  L27  L27 10 L27 11 L27 12 L27 1 L27 1 L27 15 L27 5 L27  L27  L27 2 L27 0 L27  L27  L27  L27  L27  L27 5 L27  L27 55L27 0 L27 5 L27 5 L27 5 L27 5 L27 5 L27 L27 5 L27 52 L27 51 L27 50 L27  L27  SIGN 7<PE "C" SIGN 7<PE "02DI)IED D" SIGN 7<PE "D" CUR% S7ENCIL DE7AIL  N7S )IRE LANE N2 PAR.ING %LAC. 7RA))IC GRADE PAIN7ED )IRE LANE S7ENCILING 0INI0U0 LE77ER HEIGH7  INCHES :I7H A 0INI0U0 12" S7R2.E SPACED EVER< 25 )EE7 2R AS N27ED 151 :LQG\ HLOO LDQH:LQFKHVWHU VLUJLQLD 22027HOHSKRQH: 50 215)D[: 50 2252ZZZ.JUHHQZD\HQJ.FRPFND1971ENGINEERINGSHEE7 2) DESIGNED %<: )ILE N2. SCALE: DA7E:PR2UDL< SERVING VIRGINIA :ES7 VIRGINIA2))ICES IN: :INCHES7ER VA ASH%URN VA 0AR7INS%URG :V1" = 50'  05152025 =- .AS  51 2L SCALE: 1" = 50' 50 25 0 50 100 N27ES: 1.)IRE S7RIPING N27 72 %E PAIN7ED A7 DRIVE:A< EN7RANCES 2.S7ANDARD CUR% )IRE S7RIPING 72 INCLUDE CUR% S7ENCIL EVER< 25' AS APPLICA%LE. SEE CUR% S7ENCIL DE7AIL. .)IRE H<DRAN7 L2CA7I2NS SH2:N PER DESIGN PLANS. LEGEND PR2P2SED <ELL2: )IRE S7RIPING 7HIS VIE: )2R )IRE LANE 0AR.INGS SIGNAGE 2NL<LI)E SA)E7< PLANRED %UD 0AGIS7ERIAL DIS7RIC7)REDERIC. C2UN7< VIRGINIASENSEN< VILLAGEPHASE IIRHY. NR.DDWH 02 012025 06Feb2026 US HOME CORPORATION WMWMWMWMWMWMWM WMWMWMWMWMWMWMWM WMSSSSSSSSSWWWWWWWWWWLOT 2LOT 1 LOT 8 LOT 9 LOT 16LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 10 LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 BMP #1 / WET POND 3 BMP #3 / JELLYFISH RIVANNA PL.LEHIGH DR.(PUBLIC)RETAINING WALL #2 (DESIGN BY OTHERS), SEE SHEET 46 EXISTING WET POND 1 10+00 11+00 12+00 13+00 13+80.77XXXX 558 556 556 634632630636638640642593.25594596598598.25599.75599.95605.5602604605.5600600 598 598.7 5 599.7 5 599.9 5 600600.75600.75599.75598.75596599.75599.75598.255985965946 1 2 6 1 86166 1 4 6 1 0 620 622 624 620622624618616 626 628 626 61261661462261 2 6 1 0 60 8 60 6 60 4 60 2 606 602 604 608 610 599. 7 5 596 598 598. 2 5 599. 9 5 6025845865885905925945965986006 1 6 6186 2 0 6 2 2 6 2 4 626626626 6 2 8560562564566568570572574576578580582584586584582580578576574572570566564600600 600.75600.75568 582 584 604 588592594596598602600590566 602 600 598 596 594 592 590 588 586 580 578 576 574 572 570 558 558 568AQU A TI C B E N C H AQU ATI C B E N C H AQ U A T I C B E N C H AQUATICBENCHSAF E T Y BEN C H SAF E T Y BE N C H SAFETYBENCHAQU ATI C B E N C H SAFETY BENCH6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 8 8 8 8 8 8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.40.4 0.4 0.5 0.5 0.5 0.5 0.7 0.7 0.8 0.8 0.9 1.1 1.6 0.0 1.6 1.1 1.4 1.5 2.4 1.5 1.4 A @ 18' 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.3 0.4 0.40.5 0.5 0.5 0.7 0.8 1.1 1.6 0.0 1.6 1.1 1.4 1.5 2.4 1.5 1.4 A @ 18' 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.30.4 0.5 0.7 0.8 9 9 10 10 10 3 2 2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 44 4 4 4 4 4 4 44 44 44 1 3 3 4 LIGHT POLE TYP.151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVN/A 48 RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIA05/15/2025 ZJ, KAS ---- 51 3924LSENSENY VILLAGEPHASE IISCALE: 1" = 50' 50 25 0 50 100 LANDSCAPE NOTES: SIZE OF THE PLANTINGS UTILIZED IN PLAN VIEW IS TO DIFFERENTIATE BETWEEN TREE TYPES/SPECIES, ACTUAL PLANT SIZES ARE AS SHOWN IN PLANT SCHEDULE MATCH LINE - SEE SHEET 49 LANDSCAPE AND LIGHTING PLANRev. No.Date 06 06/29/2026 TYPICAL PHOTOMETRIC PATTERN NOT TO SCALE 0.00.00.00.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.00.00.00.00.00.00.00.00.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.00.0 0.00.0 0.0 0.0 0.00.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.20.2 0.2 0.2 0.2 0.30.3 0.4 0.4 0.4 0.5 0.50.5 0.5 0.7 0.7 0.80.8 0.9 1.1 1.6 0.0 1.6 1.1 1.41.52.41.51.4 A @ 18' NOTE: 1.ALL LIGHTING WILL CONFORM TO SECTION 165-807.04.A.1 AND BE FULL DOWNCAST, SHIELDED, AND FULL CUTOFF. 18' TYPICAL 18' LIGHT POLE DETAIL NOT TO SCALE CONCRETE LIGHT POLE BASE (DESIGN BY STRUCTURAL ENGINEER) 29Jun2026 T.M. 65-A-186J WENCE, DANE MATTHEW & SARAH ANN INST. NO 150011940 ZONE: RA USE: RESIDENTIAL T.M. 65-A-186B WERDEBAUGH RONALD F. & MELANIE J. DB. 969 PG. 1563 ZONE: RA USE: RESIDENTIAL T.M. 65-A-190 DAVIS, WILMER R. & DONNA N. INST. NO 060024340 ZONE: RA USE: VACANT T.M. 65-A-72 EFG INVESTMENTS LLC DB. 955 PG. 724 ZONE: RS USE: VACANT T.M. 65-A-186M WERDEBAUGH QUINTON T & TORREY PRISCILA G INSTR. NO 220013241 ZONE: RA USE: RESIDENTIAL SSSSSSSWMWMWMWMWMWMWM WMWMWMWMWMWMWMWM WMWMWMWMWMWMWM WMWMWMWMWMWM WMWMWMWMWMWMWMWM WMWM WMWMWMWMWMWM WMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWMWM WMWMWMWMWMWMWMWM WMSSWM SSSSSSSARV WWWWSWWWWWWWWWW W W W W W W W W W SSSWMWMLOT 2LOT 1 LOT 29LOT 30LOT 78LOT 77LOT 76LOT 71LOT 61LOT 62 LOT 31 LOT 32 LOT 33 LOT 34 LOT 35 LOT 36 LOT 37 LOT 38 LOT 39 LOT 46 LOT 40 LOT 41 LOT 42 LOT 43 LOT 44 LOT 45 LOT 24LOT 28 LOT 27 LOT 26 LOT 25 LOT 17LOT 23 LOT 22 LOT 21 LOT 20 LOT 19 LOT 18 LOT 8 LOT 9 LOT 16LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 10 LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 LOT 75LOT 74LOT 73LOT 72LOT 70LOT 63LOT 69LOT 68LOT 67LOT 66LOT 65LOT 64LOT 55 LOT 60 LOT 59 LOT 58 LOT 57 LOT 56 LOT 54 LOT 47 LOT 53 LOT 52 LOT 51 LOT 50 LOT 49 LOT 48 BMP #2 / BIORETENTION BMP #1 / WET POND 3 BMP #3 / JELLYFISH RIVANNA PL. (PRIVATE)GAP RUN DR.(PRIVATE)GAP RUN DR. (PRIVATE)RIVANNA PL.(PRIVATE)RETAINING WALL #2 (DESIGN BY OTHERS), SEE SHEET 46 RETAINING WALL #1 (DESIGN BY OTHERS), SEE SHEET 46 WWWWWWWW 634632630636638640642593.25594596598598.25599.75599.95605.5602604605.5610 606 600600 602 604 608 598 598.7 5 599.7 5 599.9 5 600600.75600.75599.75598.75596599.75599.75598.25598596594634632630636638640642644646648650652654634636638640642644646648650652638640642644646636634632632636638640 612 614 610 616 620 626 624 622 61 2 61 4 61 0 61 6 61 8 612614616614616610612614612 614 6 1 2 61 4 6 2 0 62 6 6 2 8 63 0624622 6 1 8 616 6 1 2 6 1 8 6 1 6 6 1 4 6 1 0 620 622 624 620622624618616 626 628 626 612616614612 616 614 610610 612614610632630628 626624 622620618616 614616618620622624 626628 6306166 1 8 62 0 62262462462 6 628630632634634632630628626622620618616614632 63062662462261861661461 2 6 1 0 612612 61262462062862861261461661862062261261461661862061060 8 606 602 604 608 610 599. 7 5 596 598 598. 2 5 599. 9 5 616 6 1 8 6 2 0 6226246 2 6 62 8614616618620622624626 6286 1 6 6186 2 0 6 2 2 6 2 4 626626626 6286146146146 1 4612 614614614612614612600600600.75600.75604 602 600 598 596 594 AQU A TI C B E N C H AQU ATI C B E N C H AQ U A T I C B E N C H AQUATICBENCHSAF E T Y BEN C H SAF E T Y BE N C H SAFETYBENCHAQU ATI C B E N C H SAFETY BENCH5 5 5 5 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 6 6 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 8 8 8 8 8 8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.40.4 0.4 0.5 0.5 0.5 0.5 0.7 0.7 0.8 0.8 0.9 1.1 1.6 0.0 1.6 1.1 1.4 1.5 2.4 1.5 1.4 A @ 18' 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.7 0.7 0.8 0.8 0.9 1.1 1.6 0.0 1.6 1.1 1.4 1.5 2.4 1.5 1.4 A @ 18' 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.40.4 0.4 0.5 0.5 0.5 0.5 0.7 0.7 0.8 0.8 0.9 1.1 1.6 0.0 1.6 1.1 1.4 1.5 2.4 1.5 1.4 A @ 18' 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.10.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.7 0.7 0.8 0.8 0.9 1.1 1.6 0.0 1.6 1.1 1.4 1.5 2.4 1.5 1.4 A @ 18' 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.7 0.7 0.8 0.8 0.9 1.1 1.6 0.0 1.6 1.1 1.4 1.5 2.4 1.5 1.4 A @ 18' TYPE "A" DISTANCE BUFFER/ LANDSCAPE SCREEN TYPE "A" DISTANCE BUFFER/ LANDSCAPE SCREEN TYPE "A" DISTANCE BUFFER/ LANDSCAPE SCREEN TYPE "A" DISTANCE BUFFER/ LANDSCAPE SCREEN 80' ROAD EFFICIENCY BUFFER REDUCED DISTANCE - FULL SCREEN - TYPE "A" DISTANCE BUFFER / FULL SCREEN 9 9 10 10 10 3 3 3 33 33 3 3 3 2 2 2 3 2 3 1 2 2 2 2 2 1 2 2 2 2 2 2 2 3 1 1 1 3 3 4 4 4 4 4 4 4 4 3 3 5 1 3 3 3 1 1 1 3 2 3 3 1 3 3 2 2 2 2 2 4 LIGHT POLE TYP. LIGHT POLE TYP. LIGHT POLE TYP. LIGHT POLE TYP. LANDSCAPE NOT SHOWN PER FREDERICK WATER REQUIREMNTS LANDSCAPE NOT SHOWN PER FREDERICK WATER REQUIREMNTS PROPOSED GRADING PROVIDES HEADLIGHT SCREENING (6' SLOPE)151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVN/A 49 RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIA05/15/2025 ZJ, KAS ---- 51 3924LSENSENY VILLAGEPHASE IISCALE: 1" = 50' 50 25 0 50 100 LANDSCAPE NOTES: SIZE OF THE PLANTINGS UTILIZED IN PLAN VIEW IS TO DIFFERENTIATE BETWEEN TREE. TYPES/SPECIES, ACTUAL PLANT SIZES ARE AS SHOWN IN PLANT SCHEDULE **SCREENING BUFFERS SHOWN ON PLANS IS REPRESENTATIONAL COUNTS MAY DIFFER IN FIELD DUE TO TOPOGRAPHY ETC. PLEASE SEE NEXT SHEET FOR APPROXIMATE SCREENING PLANT NUMBERS/SPECIES MATCH LINE - SEE SHEET 48 Lighting Note: All lighting will conform to §165-807.04.A1 and be fully shielded, aimed, and downcast.LANDSCAPE AND LIGHTING PLAN (2)Rev. No.Date 06 06/29/2026 29Jun2026 TOWNHOUSE/MULTIPLEX SHRUB PLANTING DETAIL, TYP. END UNITS - One (1) CEANOTHUS AMERICANUS (NEW JERSEY TEA) and One PHYSOCARPUS OPULIFOLIUS (NINEBARK)EACH CENTRAL UNITS - ONE (1) PHYSOCARPUS OPULIFOLIUS (NINEBARK) EACH *NOTE: SOME TOWNHOUSE / TOWNHOUSE STICK SHRUB PLACEMENT MAY DIFFER FROM DETAIL DUE TO INDIVIDUAL TOWNHOUSE FOOTPRINT ORIENTATION, SEE LANDSCAPE PLANS TO VERIFY PLACEMENT. 6 7 7 7 7 7 7 7 6 RIVANNA PL. (PRIVATE)GAP RUN DR.(PRIVATE)GAP RUN DR. (PRIVATE)RIVANNA PL.(PRIVATE)LEHIGH DR.(PUBLIC)AQU A TI C B E N C H AQU A TI C B E N C H AQUAT I C B E N C H AQUATICBENCHSAFE T Y BEN C H SAFET Y BENC H SAFETYBENCHAQU A TI C B E N C H SAFETY BENCH5 5 5 5 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 6 6 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 6 7 7 7 7 7 7 7 6 8 8 8 8 8 8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.40.4 0.4 0.5 0.5 0.5 0.5 0.7 0.7 0.8 0.8 0.9 1.1 1.6 0.0 1.6 1.1 1.4 1.5 2.4 1.5 1.4 A @ 18' 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.7 0.7 0.8 0.8 0.9 1.1 1.6 0.0 1.6 1.1 1.4 1.5 2.4 1.5 1.4 A @ 18' 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.40.4 0.4 0.5 0.5 0.5 0.5 0.7 0.7 0.8 0.8 0.9 1.1 1.6 0.0 1.6 1.1 1.4 1.5 2.4 1.5 1.4 A @ 18' 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.10.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.7 0.7 0.8 0.8 0.9 1.1 1.6 0.0 1.6 1.1 1.4 1.5 2.4 1.5 1.4 A @ 18' 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.7 0.7 0.8 0.8 0.9 1.1 1.6 0.0 1.6 1.1 1.4 1.5 2.4 1.5 1.4 A @ 18'9 9 10 10 10 3 3 3 33 33 3 3 3 2 2 2 3 2 3 1 2 2 2 2 2 1 2 2 2 2 2 2 2 3 1 1 1 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 44 4 4 4 4 4 4 44 44 4 4 3 3 5 1 3 3 3 1 1 1 3 2 3 3 1 3 3 2 2 2 2 2 4 FRONTAGE PROVIDED = 540 FT FRONTAGE PROVIDED = 240 FT FRONTAGE PROVIDED = 1,250 FT LIGHT POLE TYP.LIGHT POLE TYP. LIGHT POLE TYP. LIGHT POLE TYP. PROPOSED GRADING PROVIDES HEADLIGHT SCREENING (6' SLOPE) ROAD EFFICIENCY BUFFER LANDSCAPE CALCULATIONS EAST SIDE OF SITE AT END OF ROAD 3 PLANTS PER 10 LF REQUIRED 344/10 * 3 = 104 PLANTS REQUIRED 104 PLANTS PROVIDED ADDITIONAL TWO ROWS OF EVERGREEN TREES (6' TALL AT TIME OF PLANTING) PROVIDED TO MEET FULL SCREEN REQUIREMENTS 151 Windy Hill LaneWinchester, Virginia 22602Telephone: (540) 662-4185Fax: (540) 722-9528www.greenwayeng.comFND1971ENGINEERINGSHEET OF DESIGNED BY: FILE NO. SCALE: DATE:PROUDLY SERVING VIRGINIA & WEST VIRGINIAOFFICES IN: WINCHESTER, VA, ASHBURN, VA & MARTINSBURG, WVN/A 50LANDSCAPE AND LIGHTING PLAN (3)RED BUD MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIA05/15/2025 ZJ, KAS ---- 51 3924LSENSENY VILLAGEPHASE II3" EARTH SAUCER EXISTING SUB-BASE BACKFILL WITH SOIL MIX OF 3/4 EXISTING SOIL & 1/4 ORGANIC MATTER REMOVE BURLAP FROM TOP 1/2 OF ROOT BALL SET TOP 1/8 OF ROOT BALL ABOVE FINISHED GRADE REMOVE PROBLEM, DISEASED OR WEAK BRANCHES ONLY. LEAVE PLANT'S NATURAL FORM INTACT 3" MULCH 6" MIN 12" MIN NOTES: 1. ALL PLANTINGS SHALL CONFORM WITH §165-802.06 OF THE FREDERICK COUNTY ZONING ORDINANCE (PLANT SELECTION, PLANTING PROCEDURE, AND MAINTENANCE) 2. ANY PLANT SUBSTITUTIONS MUST BE APPROVED IN WRITING BY THE FREDERICK COUNTY PLANNING DEPARTMENT. 3. DISTURBED AREAS OF SWM FEATURES NOT IDENTIFIED AS BEING PLANTED SHALL BE SEEDED. 4. ALL SEEDED AND SODDED AREAS OF PROJECT WILL BE OF A DROUGHT TOLERANT MIX PER PENNINGTON SEED COMPANY NO SLOPE IN EXCESS OF 25% WILL BE SEEDED. 5. *SWM FACILITY EMERGENT/SUBMERGENT VEGETATION SHOWN ON PLANT KEY MAY BE SEEDED RATHER THAN CONTAINER GROWN, WHEN AVAILABLE. 6. NO TREES OR SHRUBS SHALL BE PLACED ON FREDERICK WATER EASEMENTS OTHER THAN TREES AND SHRUBS AS SHOWN AT TERMINAL ENDS OF RIVANNA COURT AS THESE EASEMENTS ARE FOR POTENTIAL FUTURE CONNECTIONS AND LANDSCAPING CAN BE REMOVED UPON CONSTRUCTION OF THE CONECTION. GENERAL CONDITIONS SCOPE OF WORK THE LANDSCAPE CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR AND EQUIPMENT TO COMPLETE ALL LANDSCAPE WORK AS SHOWN ON THE PLANS AND SPECIFICATIONS. NOTE: IF CONTRACTOR BIDS ACCORDING TO THE PLANT LIST, HE/SHE SHOULD THOROUGHLY CHECK THE PLANT LIST QUANTITIES WITH THE SYMBOLS DRAWN ON THE PLAN, TO BE SURE THERE ARE NO DISCREPANCIES. IF THERE IS A DISCREPANCY BETWEEN THE DRAWING AND THE LIST ON THE PLANS, THE DRAWING TAKES PRECEDENCE. STANDARDS ALL PLANT MATERIAL WILL CONFORM TO THE CURRENT ISSUE OF THE AMERICAN STANDARD FOR NURSERY STOCK PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION (ANLA).PLANT MATERIAL MUST BE SELECTED FROM NURSERIES THAT HAVE BEEN INSPECTED AND CERTIFIED BY STATE PLANT INSPECTORS.COLLECTED MATERIAL MAY BE USED ONLY WHEN APPROVED BY OWNER'S REPRESENTATIVE.NOMENCLATURE WILL BE IN ACCORDANCE WITH HORTUS III BY L.H. BAILEY. SUBSTITUTIONS: PRE-BID IT IS THE LANDSCAPE CONTRACTOR'S RESPONSIBILITY TO MAKE EVERY REASONABLE EFFORT TO FIND THE PLANTS SPECIFIED BY THE LANDSCAPE ARCHITECT. THE LANDSCAPE CONTRACTOR MAY OFFER SUBSTITUTIONS TO THE LANDSCAPE ARCHITECT FOR HIS/HER CONSIDERATION. THE LANDSCAPE CONTRACTOR WILL NOTIFY THE LANDSCAPE ARCHITECT IF THERE ARE KNOWN DISEASES OR INSECT RESISTANT SPECIES THAT CAN BE SUBSTITUTED FOR A SELECTED PEST-PRONE PLANT. THE CONTRACTOR SHALL SUBMIT A BASE BID AS PER PLAN PLUS PRICE CLARIFICATIONS FOR ALL RECOMMENDED SUBSTITUTIONS. SUBSTITUTIONS: POST-BID IT IS THE INTENT TO ELIMINATE POST-BID SUBSTITUTIONS. HOWEVER, IN THE EVENT THAT THE CONTRACT MATERIAL HAS BECOME UNAVAILABLE, AN APPROPRIATE SUBSTITUTION MUST BE APPROVED BY THE OWNER'S REPRESENTATIVE. UTILITIES AND UNDERGROUND FEATURES THE LANDSCAPE CONTRACTOR SHALL NOTIFY UTILITY COMPANIES AND/OR THE GENERAL CONTRACTOR IN ADVANCE OF CONSTRUCTION TO LOCATE UTILITIES. IF THERE IS A CONFLICT WITH UTILITIES AND THE PLANTING, THE LANDSCAPE ARCHITECT SHALL BE RESPONSIBLE FOR RELOCATING PLANTS PRIOR TO THE PLANTING PROCESS. ANY COST DUE TO RELOCATING AFTER PLANTING SHALL BE BORNE BY THE OWNER. IF PLANTS ARE TO BE INSTALLED IN AREAS THAT SHOW OBVIOUS POOR DRAINAGE, AND THE PLANTS ARE INAPPROPRIATE FOR THAT CONDITION, THE LANDSCAPE CONTRACTOR SHALL NOTIFY THE LANDSCAPE ARCHITECT AND OWNER. IF THEY DEEM NECESSARY, THE PLANTS SHALL BE RELOCATED, THE CONTRACT SHALL BE ADJUSTED TO ALLOW FOR DRAINAGE CORRECTION AT A NEGOTIATED COST, OR THE PLANT SELECTION MODIFIED BY THE LANDSCAPE ARCHITECT TO ACCOMMODATE THE POOR DRAINAGE. WARRANTY THE STANDARD WARRANTY IS FOR ONE (1) YEAR PERIOD, EXCLUDING BULBS, SOD AND ANNUALS, COMMENCING ON THE DATE OF INITIAL ACCEPTANCE. ALL PLANTS SHALL BE ALIVE AND IN SATISFACTORY GROWTH AT THE END OF THE GUARANTEE PERIOD. ANY MATERIAL THAT IS 25% DEAD OR MORE SHALL BE CONSIDERED DEAD AND MUST BE REPLACED AT NO CHARGE. A TREE SHALL BE CONSIDERED DEAD WHEN THE MAIN LEADER HAS DIED BACK, OR 25% OF THE CROWN IS DEAD. REPLACEMENTS SHALL BE MADE DURING THE NEXT PLANTING PERIOD. REPLACEMENTS SHALL BE OF THE SAME TYPE, SIZE AND QUALITY AS ORIGINAL SPECIES UNLESS OTHERWISE NEGOTIATED. STANDARDS A. PLANTS WILL BE IN ACCORDANCE WITH THE CURRENT ANLA'S STANDARDS AND CONFORM IN GENERAL TO REPRESENTATIVE SPECIES. B. BALLED AND BURLAPPED (B&B) 1. BALLED AND BURLAPPED PLANTS SHALL BE DUG WITH FIRM ROOT BALLS FREE OF NOXIOUS WEEDS. THERE SHOULD BE NO EXCESS SOIL ON TOP OF THE ROOTBALL OR AROUND THE TRUNK 2. BALL SIZES SHALL BE IN ACCORDANCE WITH ANLA STANDARDS. 3. CALIPER AND HEIGHT MEASUREMENT: IN SIZE GRADING B&B SINGLE TRUNK TREES, CALIPER SHALL TAKE PRECEDENCE OVER HEIGHT. CALIPER OF THE TRUNK SHALL BE TAKEN 6" ABOVE GROUND LEVEL (UP TO AND INCLUDING 4" CALIPER SIZE) AND 12" ABOVE THE GROUND LEVEL FOR LARGER TREES. FOR MULTIPLE-TRUNK TREES, HEIGHT MEASUREMENT SHALL TAKE PRECEDENCE OVER CALIPER. C. CONTAINER - GROWN STOCK 1. THE SIZE OF CONTAINER-GROWN SHRUBS IS MEASURED BY HEIGHT AND WIDTH OF THE PLANT. CONTAINER-GROWN TREES ARE MEASURED BY THE SAME STANDARDS LISTED IN B.3. ABOVE. THE ROOT SYSTEM OF CONTAINER-GROWN PLANTS SHALL BE WELL DEVELOPED AND WELL DISTRIBUTED THROUGH OUT THE CONTAINER. 2. ALL CONTAINER-GROWN TREES AND SHRUBS THAT HAVE CIRCLING (GIRDLING) AND MATTED ROOTS SHALL BE TREATED IN THE FOLLOWING MANNER PRIOR TO PLANTING: SEPARATE THE ROOTS BY HAND, UNTANGLING SO CIRCLING ROOTS WILL NOT DAMAGE FUTURE OF THE PLANT. SEE PLANTING PROCEDURES FOR ALL CONTAINER-GROWN TREES & SHRUBS IN THIS SECTION. 3. ALL CONTAINER-GROWN PLANTS SHOULD BE GROUPED AND WATERED DAILY UNTIL THEY ARE PLANTED IN THE LANDSCAPE, THE SOIL SHALL BE KEPT MOIST WITH THE EQUIVALENT OF ONE-INCH OF RAINFALL PER WEEK. D. PRUNING SHALL BE DONE BEFORE PLANTING OR DURING THE PLANTING OPERATION. PRUNING DETAIL FOR TREES IN THIS SECTION. E. ALL PLANT MATERIAL IN TRANSIT SHALL BE COVERED TO KEEP MATERIAL FROM DRYING OUT. THE COVERING SHALL COMPLY WITH THE STATE AND LOCAL LAWS PERTAINING TO THE TRANSPORT OF MATERIALS. F. TREES SHALL BE PLACED IN AN UPRIGHT POSITION WITH THE ROOTBALL COVERED BY MULCH AND KEPT MOIST. TREES AND SHRUBS SHOULD NOT BE LEFT ON SITE UNPLANTED FOR MORE THAN 24-HOURS WITHOUT ADEQUATE WATER TO INSURE ROOT SURVIVAL. INSPECTION A. PLANTS MAY BE SUBJECT TO INSPECTION AND APPROVAL BY THE OWNER OR OWNER'S REPRESENTATIVE AT THE PLACE OF GROWTH OR HOLDING YARD FOR CONFORMITY TO SPECIFICATION REQUIREMENTS AS TO QUALITY, SIZE AND VARIETY. B. PLANTS DAMAGED IN HANDLING OR TRANSPORTATION CAN BE REJECTED BY THE OWNER OR OWNER'S REPRESENTATIVE. C. STATE NURSERY INSPECTION CERTIFICATES SHALL BE FURNISHED TO THE LANDSCAPE ARCHITECT UPON REQUEST. PLANTING PROCEDURES FOR ALL CONTAINER-GROWN TREES & SHRUBS A. REMOVE THE PLANT EITHER BY CUTTING OR INVERTING THE CONTAINER. B. FOR UNTREATED PLASTIC CONTAINER-GROWN PLANTS WITH CIRCLING ROOTS, SEPARATE ROOTS BY HAND AND UNTANGLE ROOTS THE LENGTH OF THE ROOTBALL. C. PLANT SHRUB OR TREE A MINIMUM OF 18 OF THE HEIGHT OF THE ROOTBALL ABOVE EXISTING GRADE. D. APPLY A 2 TO 3" THICK LAYER OF APPROVED HARDWOOD MULCH. KEEP MULCH 6" AWAY FROM THE TRUNK OF ALL TREES AND SHRUBS. E. PLANTS GROWN IN ROOT CONTAINMENT BAGS MUST HAVE BAGS REMOVED DURING THE PLANTING OPERATION. NO ADDITIONAL SLASHING OF THE ROOTBALL IS NECESSARY. LANDSCAPE NOTES: SIZE OF THE PLANTINGS UTILIZED IN PLAN VIEW IS TO DIFFERENTIATE BETWEEN TREE. TYPES/SPECIES, ACTUAL PLANT SIZES ARE AS SHOWN IN PLANT SCHEDULE 1. TYPE "A" DISTANCE BUFFER / FULL SCREEN: PROVIDE A 25' WIDE DISTANCE BUFFER WITH A 15' WIDE INACTIVE PORTION AND 10' WIDE ACTIVE PORTION. RESIDENTIAL BUFFER LANDSCAPE CALCULATIONS 20' ACTIVE 30' INACTIVE 50' 1.3 PLANTS PER 10L.F. PLANT SHALL BE 1/3 DECIDUOUS, 1/3 EVERGREENS, AND 1/3 SHRUBS. 2.ALL PLANTINGS/SUBSTITUTIONS TO BE FROM THE APPROVED LIST IN THE FREDERICK COUNTY ZONING ORDINANCE. TYPE "A" 50' LANDSCAPE SCREEN / BUFFER not to scale TYPE "A" 25' FULL SCREEN / BUFFER not to scale 2. TYPE "A" DISTANCE BUFFER/ LANDSCAPE SCREEN: PROVIDE A 50' WIDE DISTANCE BUFFER WITH A 30' WIDE INACTIVE PORTION AND 20' WIDE ACTIVE PORTION. SOUTHEAST CORNER & SOUTH SIDE OF SITE (1,000' BUFFER) 3 PLANTS PER 10 LF REQUIRED 1,000/10 * 3 = 300 PLANTS REQUIRED 311 PLANTS PROVIDED SOUTH SIDE OF SITE AT END OF ROAD (54' BUFFER) 3 PLANTS PER 10 LF REQUIRED 54/10 * 3 = 17 PLANTS REQUIRED 18 PLANTS PROVIDED ADDITIONAL TWO ROWS OF EVERGREEN TREES (6' TALL AT TIME OF PLANTING) PROVIDED TO MEET FULL SCREEN REQUIREMENTS 10' ACTIVE 15' INACTIVE 25' 1.3 PLANTS PER 10L.F. PLANT SHALL BE 1/3 DECIDUOUS, 1/3 EVERGREENS, AND 1/3 SHRUBS. 2.A 6' OPAQUE FENCE OR EARTHEN BERM MAY BE SUBSTITUTED BY THE APPLICANT FOR THE 5 PLANTS PER 10LF (DOUBLE ROW OF EVERGREENS) 3.ALL PLANTINGS/SUBSTITUTIONS TO BE FROM THE APPROVED LIST IN THE FREDERICK COUNTY ZONING ORDINANCE. DOUBLE ROW EVERGREENS ROW OF ALTERNATING EVERGREENS/DECIDUOUS ROW OF SHRUBS ROW OF ALTERNATING EVERGREENS/DECIDUOUS ROW OF SHRUBS PROPOSED SWM FACILITY PLANTINGS 8 Elodea canadensis & Vallisneria americana Pond weed & Wild celery 24" O.C., co - mingle, (1,412 sf ) 353 353 9 Panicum virgatum & Acorus calamus Switchgrass & Sweet Flag 24" O.C., co - mingle, (2,895 sf ) 362 362 10 Carex spp & Scipus validus Sedge & Soft-stem Bulrush 24" O.C., co - mingle, (1,787 sf ) 237 237 REDUCED DISTANCEBUFFER / FULL SCREEN not to scale 40' ACTIVE 40' INACTIVE 80' 1.3 PLANTS PER 10L.F. PLANT SHALL BE 1/3 DECIDUOUS, 1/3 EVERGREENS, AND 1/3 SHRUBS. 2.A 6' OPAQUE FENCE OR EARTHEN BERM MAY BE SUBSTITUTED BY THE APPLICANT FOR THE DOUBLE ROW OF EVERGREENS 3.ALL PLANTINGS/SUBSTITUTIONS TO BE FROM THE APPROVED LIST IN THE FREDERICK COUNTY ZONING ORDINANCE. DOUBLE ROW EVERGREENS ROW OF ALTERNATING EVERGREEN TREES /DECIDUOUS TREES /SHRUBS 1. REDUCED DISTANCE BUFFER / FULL SCREEN: PROVIDE AN 80' WIDE DISTANCE BUFFER WITH A 40' WIDE INACTIVE PORTION AND 40' WIDE ACTIVE PORTION. PROP LINE ANGLE CUTS OFF FULL BUFFER 5 5 Red Sunset Maple Acer rubrum 'Red Sunset' 2.5" cal PROPOSED PLANTINGS 5 BOTANIC NAME COMMON NAME QUANTITY SIZE Thuja occidentalis 'Emerald"Emerald Green Arborvitae 4' ht. 36" cont. Thuja occidentalis 'Emerald"91 89 131 David Viburnum Viburnum davidii TYPE "A"- 25' DISTANCE BUFFER - FULL SCREEN TYPE "A"- 50' DISTANCE BUFFER - LANDSCAPE SCREEN Red Sunset Maple Acer rubrum 'Red Sunset' Emerald Green Arborvitae David Viburnum Viburnum davidii 2.5" cal 4' ht. 36" cont. BUFFER/ SCREEN PLANT SCHEDULE Thuja occidentalis 'Emerald"34 33 37 ROAD EFFICIENCY BUFFER - FULL SCREEN Red Sunset Maple Acer rubrum 'Red Sunset' Emerald Green Arborvitae David Viburnum Viburnum davidii 2.5" cal 4' ht. 36" cont. STREET TREES REQUIRED: 1 STREET TREE FOR EVERY 40' OF FRONTAGE 2,030 LF OF FRONTAGE PROPOSED: 2,030 / 40 = 51 STREET TREES REQUIRED (52 PROVIDED) ORNAMENTAL TREES REQUIRED: (TOWNHOUSE UNITS) 2 ORNAMENTAL TREES FOR EVERY 5 UNITS (TOWNHOUSE ONLY) 78 TOWNHOUSE UNITS (78 / 5 X 2) = 31 ORNAMENTAL TREES REQUIRED (35 PROVIDED) ORNAMENTAL SHRUBS REQUIRED: (TOWNHOUSE UNITS ONLY) 6 ORNAMENTAL SHRUBS FOR EVERY 5 UNITS (TOWNHOUSE ONLY) 78 TOWNHOUSE UNITS (78 / 5 X 6) = 94 ORNAMENTAL SHRUBS REQUIRED (98 PROVIDED) INTERIOR PARKING LOT LANDSCAPING: 1 TREE PER 10 SPACES 42 SPACES PROPOSED/10= 4 TREES REQUIRED (18 PROVIDED) PARKING LOT HEADLIGHT SCREENING SHRUBS PROVIDED: 206 PROVIDED TOTAL TREES REQUIRED: 86 TOTAL TREES PROVIDED: 87 SHRUBS AND TREES 25 22 10 London plane treePlatanus acerifolia 1.25" cal PROPOSED TREE PLANTINGS PROPOSED SHRUB PLANTINGS 30 KEY BOTANIC NAME COMMON NAME QUANTITY SIZE 1 Quercus phellos Willow Oak Gymnocladus dioicus Kentucky Coffeetree2 3 4 1.25" cal 2.5" cal 2.5" cal 3' ht. min.Prunus laurocerasus Laurel5 206 6 Ceanothus americanus New Jersey Tea 7 20 79Physocarpus Opulifolius Ninebark male only Silver LindenTilia tomentosa Rev. No.Date 06 06/29/2026 SCALE: 1" = 200' 200 0 200 400 ROW OF SHRUBS Thuja occidentalis 'Emerald"77Emerald Green Arborvitae 6' ht. 22Thuja occidentalis 'Emerald"Emerald Green Arborvitae 6' ht. 29Jun2026 N/A  // =-.A6   /:LQG\+LOO/DQH:LQFKHVWHU9LUJLQLD7HOHSKRQH  )D[  ZZZJUHHQZD\HQJFRPFND1971ENGINEERING6+((72) '(6,*N('%< ),/(N2 6&A/( 'A7(3528'/<6(59,N*9,5*,N,A :(679,5*,N,A2)),&(6,N:,N&+(67(59AA6+%85N9A 0A57,N6%85*:9352))(565('%8'0A*,67(5,A/',675,&7)5('(5,&.&28N7<9,5*,N,A6(N6(N<9,//A*(3+A6(,,5HYNR'DWH  06Feb2026