Loading...
HomeMy WebLinkAbout06. SP#48-25 2nd Submission Comment Response Letter kimley-horn.com 11400 Commerce Park Drive, Suite 400, Reston, VA 20191 703 674 1300 February 27, 2026 To: County of Frederick, Virginia Re: Comment Response Site Plan #48-25: Firestone Auto Center Dear Eric Bittner Please find the following responses addressing comments received in letters from various county and state departments: Department of Planning and Development Comment 1a: Provide the Power of Attorney with wet signatures. Not addressed, received was a photo-copy, a wet signature copy is still required. Response 1a: Power of Attorney with wet signatures has been included with this submission package. Comment 4a: Parking space location. Provide the parking setback lines on the site plan. (§165-202-01(D)(6)). Parking setbacks apply to all four sides of the property. Partially addressed, parking setbacks apply to other property lines. Response 4a: Per correspondence with Eric on February 19th, “Interior lot lines aren't exempt from the parking standards: they have a 5' setback (from the property line) rather 10' from the ROW line.” 5’ setbacks have been added to the plans. The access drive to the east is now a named roadway. As such, setbacks are now shown along that boundary. Comment 4c: Setback: Include the actual setbacks for all property lines. Partially addressed. Provide the actual distance from the building to each property line. Response 4c: Actual distances from the building to each property line/ egress easement have been added to the plans. See sheet C01.1. Comment 4d: Final Paving: The road within the ingress/egress easement between Market Street and Martinsburg Pike must be paved and finished. Not addressed. Include final pavement or produce agreements assuring completion by others. Response 4d: The area needing paving and finishing has been highlighted and a note has been added instructing the contractor to complete the work. See sheet C01.1. Comment 9: Agency Approvals: Comment sheets (approvals) are required from the following agencies: the Frederick County Inspections Department, the Frederick County Page 2 kimley-horn.com 11400 Commerce Park Drive, Suite 400, Reston, VA 20191 703 674 1300 Fire Marshal, the Virginia Department of Transportation (VDOT), Frederick County G.I.S., Winchester Airport, Frederick Water, and the Frederick County Engineer (Public Works). Response 9: Acknowledged. Approvals are included in this submission package. Comment 10: Resubmittal fee: Provide the $500 resubmittal fee for the 3rd submission. Response 10: Acknowledged. The $500 resubmittal fee is included in this submission package. Frederick Water Comment 1: REPLACE WITH ‘REMOVE GATE VALVE AND INSTALL MJ PLUG IN TEE’ Response 1: The note has been updated to include the above information. See sheet C02. Comment 2: LABEL; HP PROTECTUS 3 STAINLESS STEEL FIRE METER AND INCLUDE DIAMETER Response 2: The label has been updated to call out the 6” HP Protectus III Stainless Steel Fire Meter. See sheet C05. Comment 3: ADD; ‘WITH BOLLARDS’ Response 3: This note has been added. See sheet C05. Comment 4: MIN. 10’ FW ESMT REQ’D AROUND FH Response 4: The easement has been updated to 10’. See sheet C05. Comment 5: ADD; 1” Response 5: The size has been called out on the plans. See sheet C05. Comment 6: ALSO STATE DEMANDS IN GPD; DOMESTIC AND IRRIGATION INDIVIDUALLY Response 6: A standalone flow model has been provided separately with the application. Please refer to this document for resolution of this comment. Comment 7: Demonstrate that the flow and pressure criteria required by the FW standards and specifications can be met with the proposed system. Long form calculations or a digital hydraulic model is acceptable. Calculations or a summary of model results shall be sealed by a Professional Engineer licensed in the Commonwealth of Virginia and submitted under separate cover with the Site Plan. A brief summary of the model or calculations shall be included in the Site Plan package but shall not exceed one 24”x36” page in length. The Frederick Water Engineer will inform the applicant as to which pages of the model results shall be included on the Site Plan sheet once the stand-alone report has been deemed Page 3 kimley-horn.com 11400 Commerce Park Drive, Suite 400, Reston, VA 20191 703 674 1300 acceptable. Response 7: A standalone flow model has been provided separately with the application. Pending satisfactory resolution of the flow model comments, Kimley-Horn with coordinate with Frederick Water to confirm which sheets from the flow model to include on the signature set plans. Comment 8: Water Model submission requirements: Brief narrative of the project, what is being modeled, and what the model intends to demonstrate Standards being evaluated (e.g., fire flow requirement (GPM based on use), minimum pressure of 20 psi during fire flow). Anticipated flows for the project including calculations of the applicable fire flow plus the greater of (a) maximum hour flow or (b) maximum day flow. Figures including a vicinity map, project layout, existing Frederick Water facilities near the project, water model layout with nodes, pipes, pumps, etc. labled. Results of the hydrant test that established the boundary condition for the model or other means of simulating the existing Frederick Water system. Pump curve that represents the connection to the existing FW system. Table showing all pipes in the model. Attributes shall include pipe length, diameter, roughness, velocity, etc. Table showing all nodes in the model. Attributes shall include assigned flows, elevation, pressure, etc. Table showing the results of the fire flow analysis including flows and residual pressures Response 8: A standalone flow model has been provided separately with the application. Please refer to this document for resolution of this comment. Comment 9: ADD DETAIL THIS SHEET Response 9: HP Protectus 3 Stainless Steel Fire Meter details have been added to the plans. See sheet C10. Sincerely, Chris Howell, P.E.