Loading...
HomeMy WebLinkAbout01. SP#48-25 Firestone Complete Auto Care Site PlanThis document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCCOVER SHEETC00 SITE PLAN SP#48-25 FIRESTONE COMPLETE AUTO CARE STONEWALL MAGISTERIAL DISTRICT TAX PARCEL 43-A-100F CORNER OF MARKET STREET AND MERCHANT STREET INTERSECTION WINCHESTER, FREDERICK COUNTY, VA 2/27/2026 KIMLEY-HORN AND ASSOCIATES, INC. 11400 COMMERCE PARK DRIVE, SUITE 400 RESTON, VA 20191 PHONE: 202-350-32 CONTACT: HEATHER TIMOTHY EMAIL: HEATHER.TIMOTHY#KIMLEY-HORN.COM APPLICANT =AREMBA GROUP, LLC 14600 DETROIT AVE, SUITE 1500, LAKEWOOD, OH 44107 PHONE: 216-221-2163 CONTACT: TODD HAMULA EMAIL: THAMULA#=AREMBAGROUP.COM LAND OWNER RUTHERFORD FARM, LLC 230 LEESBURG PIKE SUITE 620 VIENNA VA 2212 PHONE: 703-44-4312 CIVIL ENGINEER VICINITY MAP - PROJECT BOUNDARIES 1 500 SITE FREDERICK COUNTY SITE PLAN STATISTICS APPLICANT =AREMBA GROUP, LLC DEVELOPER =AREMBA GROUP, LLC TAX PARCEL ID 43-A-100F MAGISTERIAL DISTRICT STONEWALL EXISTING AND PROPOSED =ONING B3 EXISTING USE VACANT LOT PROPOSED USE AUTOMOBILE SERVICE SITE DATA: PROPERTY AREA 2.9553 AC PROJECT AREA 2.9553 AC DISTURBED AREA 1.1746 AC TOTAL IMPERVIOUS AREA 0.696 AC FRONT BUILDING SETBACK 35 FEET FRONT LANDSCAPE BUFFER 10 FEET PARKING RE4UIRED SERVICE BAYS  : 2 SPACES PER BAY 16 SPACES OFFICE 2,249 SF : 1 SPACE 1/250SF 9 SPACES RETAIL 41 SF : 1 SPACE 1/200SF 5 SPACES ADA: 26-50 PROVIDED SPACES 2 ADA SPACES RE4UIRED PARKING PROVIDED 33 PARKING SPOTS PROVIDED 31 STANDARD, 2 ADA 1 LOADING SPACE  SERVICE BAYS PERCENTAGE OF PROPERTY LANDSCAPED 14.39 PERCENTAGE OF WOODLANDS DISTURBED 0 INTERIOR LANDSCAPING RE4UIRED 1130 SF INTERIOR LANDSCAPING PROVIDED 1134 SF MINIMUM PERIMETER TREES RE4UIRED 17 MINIMUM PERIMETER TREES PROVIDED 17 MINIMUM PERIMETER SHRUBS RE4UIRED 30 MINIMUM PERIMETER SHRUBS PROPOSED 30 PERMITS NAME PERMIT NUMBER DATE STATUS PERMIT APPROVAL BLOCK LAND DEVELOPMENT APPLICATION NUMBER BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB =ONING ADMINISTRATOR BBBBBBBBBBBBBBBBBBB DATE APPROVED BY THE FREDERICK COUNTY =ONING ADMINISTRATOR SITE PLAN VALID FOR FIVE 5 YEARS FROM APPROVAL DATE UTILITIES ELECTRIC: RAPPAHANNOCK ELECTRIC COOPERATIVE 137 KELLEY COURT FRONT ROYAL, VA 22630 CONTACT: 540-622-2001 GAS: WASHINGTON GAS P.O. BOX 2400 WINCHESTER, VA 22604 CONTACT: 540-69-1111 WATER/SEWER: FREDERICK WATER PO. BOX 177 WINCHESTER, VA 22604 540-6-1061 PHONE: VERI=ON 404 HILLSDALE LANE WINCHESTER, VA 22602 540-665-3156 DEVELOPER =AREMBA GROUP, LLC 14600 DETROIT AVE, SUITE 1500, LAKEWOOD, OH 44107 PHONE: 216-221-2163 CONTACT: TODD HAMULA EMAIL: THAMULA#=AREMBAGROUP.COM SITE PROJECT DESCRIPTION NARRATIVE THE PROPOSED PROJECT IS FOR A 6,607 SF AUTO CARE CENTER. THE SITE IS CURRENTLY VACANT AND IS =ONED B-3 - INDUSTRIAL TRANSITION DISTRICT. THE PROPOSED IMPROVEMENTS WILL CONSIST OF PAVING, UTILITIES, AND LANDSCAPING. PLEASE REFERENCE THE APPROVED RUTHERFORD CROSSING SITE PLAN 55-07 AND ORIGINAL SITE PLAN 13-07 , APPROVED MASTER SITE PLAN 14-06, AND RE=ONING 17-06 FOR FULL PROFFERS. BUILDING AREAS TYPE AREA (S.F.) SHOWROOM AREA RETAIL 41 INVENTORY AREA OFFICE 1,34 ACCESSORY USE AREAS OFFICE 415 TOTAL BUILDING 6,607 SHEET INDEX SHEET NUMBER SHEET TITLE C00 COVER SHEET C01 SITE PLAN C01.1 OVERALL SITE PLAN C01.2 FIRE SAFETY PLAN C02 DEMOLITION PLAN C03 GRADING DRAINAGE PLAN C03.1 DRAINAGE AREA MAP C03.2 STORMWATER MANAGEMENT NARRATIVE C04 EROSION SEDIMENT CONTROL PLAN C04.1 EROSION SEDIMENT CONTROL NOTES C04.2 EROSION SEDIMENT CONTROL DETAILS C05 UTILITY PLAN C05.1 DRAINAGE UTILITY PROFILES L07 LANDSCAPE PLAN L07.1 LANDSCAPE NOTES DETAILS L0IRRIGATION PLAN L0.1 IRRIGATION DETAILS L0.2 IRRIGATION NOTES C09 SITE DETAILS 1 OF 2 C10 SITE DETAILS 2 OF 2 C11 PROFFERS 1 OF 2 C12 PROFFERS 2 OF 2 ALTA 1 ALTA SURVEY PSL 1 LIGHTING PLAN PSL 2 LIGHTING DETAILS FLOOR AREA RATIO: ALLOWED - 1.0 PROPOSED - 6,607 / 12,733 SF 0.05 RESPONSIBLE LAND DISTURBER CERTIFICATE RDL #: _______________________________ NAME: _______________________________ TELEPHONE NUMBER: _________________ MARKET STREET M A R K E T S T R E E T MARTI N S B U R G PI K E S N OW D E N B R I D G E B L V DI-1M I L T O N R A Y D R WELLTOWN RD WWW W W W W W W W W W WWWWWEEEEEWWWWWWW W W W W W STOP STOPSTOP TTTTTT 10 P.R.L. 35 B.R.L.35 B.R.L.10 P.R.L.W5 P.R.L.5 P.R.L.19  4 LODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODFIRESTONE BUILDING 173 HARVEY DR. ER PROTOTYPE HEIGHT 25.5 “ 6,607 SF TRAS H ENCL OS U R E USE D TI R E ENCL O S U R E R10 R 1 0 20.0 TYP. 9.0 TYP. .00 3.0 PROPOSED 24X24 STOP SIGN R1-1 24.0 PROPOSED ADA PARKING SIGN 24.0 LIMITS OF PROPOSED CONCRETE PAVING TIE TO EXISTING PAVEMENT, CURB, AND GUTTER LIMITS OF PROPOSED CONCRETE PAVING TIE TO EXISTING PAVEMENT, CURB, AND GUTTER LIMITS OF PROPOSED CONCRETE PAVING TIE TO EXISTING PAVEMENT, CURB, AND GUTTER LIMITS OF PROPOSED CONCRETE PAVING TIE TO EXISTING PAVEMENT, CURB, AND GUTTER51.7 46.0 PROPOSED 3 CURB FLUME R12 .00 TYP. 24.0 R5 R10 R 1 0 R 5 R10 R10 R 5 PROPOSED MONUMENT SIGN - SEE SHEET C09 R5 R3 0 5.0 R3 R 3 10.0 CONNECT TO EXISTING SIDEWALK CG-12 TYPE B RAMP 15.0 PROPOSED 24X24 STOP SIGN R1-1 PROPOSED 24X24 STOP SIGN R1-1 PROPOSED 24X24 STOP SIGN R1-1 R 1 0 VAN LOADING SIGN CG-12 TYPE B RAMP CG-12 TYPE B RAMP CG-12 TYPE B RAMP 34.7 34. 30. CG-12 TYPE B RAMP 24.0 PROPOSED STOP BAR - SEE NOTE 4 EXISTING BOLLARDS TO BE REPAINTEDSEE SHEET C10 PROPOSED CROSSWALK PROPOSED CROSSWALK 5.0 5.0 5.0 5.0 5.0 5.0 R3 R3 12 X45 LOADING SPACE LEGEND LOD PROPERTY LINE PROPOSED LIMITS OF DISTURBANCE PROPOSED VDOT CG-6 PARKING COUNT 1.FOR ALL PAVEMENT MATERIAL SPECIFICATION SEE SHEET C09. 2.ALL DIMENSIONS TO THE FACE OF THE CURB, UNLESS NOTES AS OTHERWISE. 3.PARKING SPACE STRIPING TO BE 4 WIDE WITH 2 COATS OF WHITE REFLECTIVE TRAFFIC PAINT. 4.STOP BAR STRIPING TO BE 24 WIDE SPACES AT 5 OFF CENTER WITH 2 COATS OF WHITE REFLECTIVE TRAFFIC PAINT. 5.ANY EXISTING OR PROPOSED UTILITY STRUCTURE TOP THAT WILL BE IN THE PAVED SIDEWALK OR TRAIL SHALL BE ADA COMPLIANT. 6. ALL ACCESSIBLE PARKING STALLS SHALL HAVE SIGNAGE INSTALLED PER DETAIL ON SHEET C09. 7.ALL PAVING AND EARTHWORK OPERATIONS SHALL CONFORM TO THE RECOMMENDATION OF THE GEOTECHNICAL REPORT. .CONTRACTOR TO PERFORM REPAIRS ON EXISTING ASPHALT PAVEMENT AS NEEDED DURING CONSTRUCTION. CONTRACTOR TO INSTALL ASPHALT PAVEMENT AROUND THE PERIMETER OF THE PROPERTY AS NEEDED TO PROVIDE THE FULL ACCESS DRIVE DEPICTED ON THIS PLANSHEET. 9.IN ACCESS DRIVES ADJACENT TO THE DEVELOPMENT, CONTRACTOR TO MATCH EXISTING PAVEMENT SECTION FOR ANY NEW/ REPLACEMENT ASPHALT. PAVEMENT SECTION IS BELIEVED TO BE 1.5 OF SM-9.5A SURFACE , 4 OF BM-25.0A BASE AND 6 OF VDOT 21B STONE AGGREGATE . XX PROPOSED FIRE LANE SIGN SEE SHEET C-210 GENERAL NOTES CONCRETE PAVEMENT SEE SHEET C09 HEAVY DUTY CONCRETE PAVEMENT SEE SHEET C09 CONCRETE SIDEWALK SITE BOLLARD SEE SHEET C09 PROPOSED SIGN LIGHT POLE WALL MOUNTED LIGHT PROPOSED VDOT STANDARD 6 CURB This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCNORTH SITE PLANC01 W W W W WWEEEWWW WW STOP STOPSTOP ACCESSTTTTTTTTLODLODLODLODLODLODLODLODLODLODLODLODPROPOSED FIRESTONE CONTRACTOR TO INSTALL “1 SURFACE COURSE OF ASPHALT PAVEMENT SM-9.5A IN THE AREA DELINEATED.59.34 64.97 111.13 40.11 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCNORTH OVERALL SITE PLANC01.1 WWW W W W W W W W W W WWWWWEEEEET WWWWWWW W W W W W STOP STOPSTOPEETT T T T T T T T E E E E E E T T TEE TTTTTT TTTTTT 10 P.R.L. 35 B.R.L.35 B.R.L.10 P.R.L.W5 P.R.L.5 P.R.L.PROPOSED FIRE LANE SIGN TYPE D PROPOSED FIRE LANE SIGN TYPE D PROPOSED FIRE LANE SIGN TYPE C MOUNT TO STOP SIGN POLE PROPOSED FIRE LANE SIGN TYPE D PROPOSED FIRE LANE SIGN TYPE A PROPOSED FIRE LANE SIGN TYPE C MOUNT TO STOP SIGN POLE PROPOSED FIRE LANE SIGN TYPE A PROPOSED FIRE LANE STRIPING PROPOSED FIRE LANE STRIPING PROPOSED FIRE LANE STRIPING FIRESTONE BUILDING “ 6,607 SF TRAS H ENCL OS U R E USE D TI R E ENCL O S U RE PROPOSED FIRE LANE SIGN TYPE A PROPOSED FIRE LANE STRIPING PROPOSED FIRE LANE SIGN TYPE C 227 LINEAR FEET OFFIRE HYDRANT COVER26 LIN E A R F E E T O F FIRE HY D R A N T C O V E R 45.50 FDC PROPOSED FIRE LANE SIGN TYPE D LEGEND LOD PROPERTY LINE PROPOSED LIMITS OF DISTURBANCE PROPOSED VDOT CG-6 PROPOSED FIRE LANE STRIPING PROPOSED FIRE LANE SIGN SEE SHEET C-210 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCNORTH FIRE SAFETY PLANC01.2 WWW W W W W W W W W W WWWWWEEEEET WWWWWWW W W W W W STOP STOPSTOPEETT T T T T T T T E E E E E E T T TEE TTTTTT TTTTTT 10 P.R.L. 35 B.R.L.35 B.R.L.10 P.R.L.W5 P.R.L.5 P.R.L.LODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODEXISTING FIRE HYDRANT AND BOLLARDS TO BE REMOVED. REMOVE PIPE UP TO THE MAIN. REMOVE GATE VALVE AND INSTALL MJ PLUG IN TEE. EXISTING LIGHT POLE TO BE REMOVED. REMOVE/ CAP EXISTING WIRING REMOVE EXISTING CURB INLET TOP AND REPLACE WITH GRATE INLET. REFERENCE SHEET C-300. EXISTING LIGHT POLE TO BE REMOVED. REMOVE/ CAP EXISTING WIRING EXISTING SANITARY SEWER CLEAN OUT TO BE REMOVED TO ESTABLISH NEW SEWER SERVICE. REFERENCE SHEET C-500. EXISTING ELECTRICAL E4UIPMENT TO REMAIN AND BE PROTECTED CONTRACTOR TO TEST PIT EXISTING TELEPHONE AND ELECTRIC CONDUITS PRIOR TO INSTALLATION. NOTIFY ENGINEER IF CONDUIT DEPTH CONFLICTS WITH PROPOSED GRADING OPERATIONS EXISTING FIRE HYDRANT TO REMAIN AND BE PROTECTED DURING CONSTRUCTION EXISTING FLUSHING ASSEMBLY TO BE REMOVED. REMOVE GATE VALVE AND INSTALL MJ PLUG IN TEE EXISTING CURB TO BE DEMOLISHED EXISTING HEDGE TO BE REMOVED IN IMMEDIATE VICINITY OF NEW SIDEWALK EXISTING HEDGE TO BE REMOVED IN IMMEDIATE VICINITY OF NEW SIDEWALK EXISTING SHRUBS AND VEGETATION TO BE REMOVED CONTRACTOR SHALL COORDINATE WATER MAIN SHUTDOWN WITH THE FREDERICK WATER INSPECTOR, SEE WATER MAIN CONNECTION/DISCONNECTION NOTES LEGEND LOD PROPERTY LINE PROPOSED LIMITS OF DISTURBANCE EXISTING BOLLARD EXISTING LIGHT POLE EXISTING HYDRANT EXISTING SANITARY CLEANOUT 1.THE CONTRACTOR IS TO COORDINATE THE REMOVAL/ABANDONMENT OF ALL UTILITIES WITH THE RESPECTIVE UTILITY COMPANIES. 2.ALL DEBRIS FROM THE DEMOLISHED STRUCTURES THAT IS NOT REUSED AS FILL IS TO BE DISPOSED OF ACCORDING TO ALL APPLICABLE STANDARDS. DEMOLISHED MATERIALS REUSED AS FILL MATERIAL SHALL BE IN PER THE DIRECTION OF THE SOILS ENGINEER. 3.CONTRACTOR TO HIRE CONSULTANT TO INSPECT ALL EXISTING UTILITIES THAT ARE TO REMAIN. FINDINGS ARE TO BE SUBMITTED TO THE DESIGN ENGINEER PRIOR TO CONSTRUCTION OR ORDERING SO THAT A DETERMINATION CAN BE MADE AS TO THE CONDITION OF THE EXISTING LINES. ANY UTILITIES THAT ARE IN MARGINAL CONDITION WILL NEED TO BE REPLACED. 4.ALL TEST PITS LOCATING THE EXISTING UTILITIES ARE TO BE COMPLETED PRIOR TO CONSTRUCTION OR ORDERING. 5.CONTRACTOR TO HAVE ALL UTILITIES FIELD MARKED AND THEN LOCATED BY THE SURVEYOR. ALL LOCATIONS ARE TO BE REPORTED TO THE DESIGN ENGINEER PRIOR TO CONSTRUCTION OR ORDERING. 6.ALL DEMOLITION IS TO BE PERFORMED IN STRICT CONFORMANCE WITH ALL APPLICABLE COUNTY STATE AND/OR OTHER GOVERNING BODIES STANDARDS. 7.DURING DEMOLITION, ANY HA=ARDOUS MATERIAL, SUCH AS ASBESTOS, SHALL BE REMOVED AND REMEDIATED IN ACCORDANCE WITH THE VIRGINIA DEPARTMENT OF ENVIRONMENTAL 4UALITY VDE4 STANDARDS AND ALL OTHER APPLICABLE STANDARDS. .THE REMOVAL AND/OR ABANDONMENT OF ANY SUBSURFACE STRUCTURES, INCLUDING STORAGE TANKS, MANHOLES AND PIPES, SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLE STANDARDS. 9.CONTRACTOR TO LOCATE GAS LINE PRIOR TO WORKING IN THIS AREA AND SHALL NOTIFY KIMLEY-HORN AND WASHINGTON GAS CO TO COORDINATE REMOVAL. 10.WATER AND SEWER DEMOLITION, PATCHING, ADJUSTMENTS ETC. SHALL BE PER FREDERICK WATER FW INSPECTOR S RE4UIREMENTS. EXISTING FW MATERIALS REMOVED SHALL BE FURNISHED TO FW INSPECTOR AS RE4UIRED AND NOT REUSED. 11.ALL EXISTING WATER, SEWER, AND STORM EASEMENTS RECORDED IN INSTRUMENT XXXX. 12.CONTRACTOR TO REMOVE AND REPLACE HEDGES AS NEEDED TO CONSTRUCT INLET IMPROVEMENTS. DEMOLITION NOTES EXISTING FEATURE TO BE REMOVED CONTRACTOR SHALL, AS APPLICABLE: 1.TEST PIT EXISTING MAIN S . PERFORM TEST PITTING OF THE EXISTING MAIN S IN ACCORDANCE WITH THE RE4UIREMENTS OF THE FREDERICK WATER INSPECTOR. 2.INSTALL JOINT RESTRAINTS. INSTALL JOINT RESTRAINTS ON EXISTING MAIN S IN ACCORDANCE WITH CURRENT FREDERICK WATER RE4UIREMENTS PRIOR TO SYSTEM SHUTDOWN. 3.MINIMI=E SHUTDOWN TIME. PREPARE ALL WORK AS FAR IN ADVANCE AS POSSIBLE TO MINIMI=E WATER SYSTEM SHUTDOWN DURATION. 4.PROVIDE ADE4UATE RESOURCES. ENSURE SUFFICIENT LABOR, E4UIPMENT, AND MATERIALS ARE AVAILABLE ON-SITE TO COMPLETE THE CONNECTION WORK PER THE FREDERICK WATER INSPECTOR S RE4UIREMENTS. 5.DEVELOP A SHUTDOWN PLAN. SUBMIT A DETAILED WATER SHUTDOWN PLAN FOR REVIEW AND APPROVAL BY THE FREDERICK WATER INSPECTOR. PLAN MUST ADDRESS FIRE WATCH, NIGHT WORK, AND ANY OTHER SPECIAL CONDITIONS THAT MAY BE RE4UIRED. 6.COORDINATE IN ADVANCE. SCHEDULE THE SHUTDOWN WITH THE FREDERICK WATER INSPECTOR, FREDERICK COUNTY FIRE MARSHAL, AND ALL AFFECTED CUSTOMERS A MINIMUM OF SEVEN 7 DAYS IN ADVANCE, MAKE ALL NECESSARY PREPARATIONS TO MEET THE RE4UIREMENTS OF EACH INVOLVED PARTY. WATER MAIN CONNECTION/DISCONNECTION NOTES This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCNORTH DEMOLITION PLANC02 EEEEEWWWWWWW W W W W STOP STOPSTOP TTTTTT 10 P.R.L. 35 B.R.L.35 B.R.L.10 P.R.L.5 P.R.L.5 P.R.L.LODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODFIRESTONE BUILDING FFE 692.50 690 691692692 693 692.20 FL 692.17 FL A2 A1 A5A3 691 692692 6 9 2 6926 9 2 692 692 692 6 HDPE ROOF DRAIN CONNECTION, INV 69.75 A1A1A1 CONNECT WITH INSERTA-TEE A7 692.01 FL 692.03 FL    690.96 FL 691.09 FL 691.21 FL 690.73 FL 690.30 FL 691.7 FL 691.79 FL 691.11 FL 691.45 FL 691.97 FL 692.25 BW 692.53 BW 692.53 BW 692.74 BW 692.04 FL 691.40 FL 690.0 FL 691.7 FL 691.59 SW 691.42 SW 691.65 SW691.76 SW 692.16 SW 692.21 SW 691.95 FL 691.30 HP 690.71 FL 691.0 FL 690.45 FL 691.13 FL 692.37 FL 692.55 FL 692.19 FL 691.26 FL 690.64 FL 691.20 FL 691.60 FL 691.52 FL 691.60 FL 691.75 FL 690.0 FL 691.67 FL 690.64 FL 690.59 FL 690.70 FL 691.91 FL 691.09 LP 692.19 HP 12 LF OF 15 HDPE # 0.1 54 LF OF 12 HDPE # 0.1 6 LF OF 12 HDPE # 0.79 57 LF OF 6 HDPE # 0.79 692.11 FL 691.4 FL 692.45 HP 692.4 HP 691.60 HP 691.30 HP 692.2 HP 692.37 HP2.901.933.4 4  1. 4 7 1.492.00  3.221.453.52.00 1.31 691.53 SW 691.46 SW 692.91 SW 692.9 SW 690.04 691.55691.56 691.1 LP 691.3 FL 69.31 LP 692.25 BC/TC 692.2 BC/TC OVERLAND RELIEF PATH OVERLAND RELIEF PATH 692.39 SW 692.47 SW 691.90 FL 692.33 TC 691.3 BC 692.50 TC 692.50 BC 692.50 TC 692.50 BC 692.77 TC 692.27 BC 691.53 SW 691.51 SW 691.23 SW 691.2 SW 691.5 SW 691.0 SW 692.20 FL LEGEND LOD PROPERTY LINE PROPOSED LIMITS OF DISTURBANCE EXISTING CONTOURS PROPOSED CONTOURS PROPOSED SLOPE PROPOSED SPOT ELEVATION SPOT ELEVATION LEGEND RIM RIM ELEVATION FFE FINISHED FLOOR ELEVATION TW TOP OF WALL BW BOTTOM OF WALL ME MATCH EXISTING LP LOW POINT HP HIGH POINT SW SIDEWALK PV PAVEMENT TD TOP OF DITCH BD BOTTOM OF DITCH TC TOP OF CURB BC BOTTOM OF CURB UNLABELED SPOT ELEVATIONS ARE ASSUMED TO BE AT THE FLOWLINE OR TOP OF PAVEMENT PROPOSED STORM MANHOLE PROPOSED STORM PIPE RIDGE GENERAL NOTES 1.CONTRACTOR TO MATCH EXISTING GRADE AT LIMITS OF DISTURBANCE. 2.CONTRACTOR TO COMPLY WITH GEOTECHNICAL REPORT RECOMMENDATIONS FOR COMPACTION AND SUB-BASE PREPARATION UNDER BUILDING PADS. 95 COMPACTION UNDER ALL OTHER AREAS UNLESS OTHERWISE SPECIFIED ON THESE PLANS OR WITHIN THE GEOTECHNICAL REPORT. 3.BEFORE USING ANY SECTION OF EXISTING STORM DRAIN AS PART OF THE PROPOSED STORM DRAINAGE SYSTEM, THE EXISTING PIPE SECTIONS NEED TO BE FLUSHED, INSPECTED, EVALUATED AND DEEMED IN GOOD CONDITION. 4.TC/BC ELEVATION DIFFERENCE TO BE 0.5 UNLESS OTHERWISE NOTED. 5.SEE SHEET C05.1 FOR PROFILE OF STORM PIPES. STRUCTURE TABLE STRUCTURE NAME: A1 A2 A3 A5 A7 DETAILS: VDOT DI-1 RIM: 69.30 INV IN: 65.60 VDOT DI-3C L 6 RIM: 691.73 INV IN: 67.33 INV OUT: 67.0 NYLOPLAST 24 BASIN SOLID COVER RIM: 692.36 INV IN: 67.7 INV OUT: 67.77 VDOT DI-3C L 6 RIM: 691.7 INV IN: 6.90 INV OUT: 6.40 2 45ƒ BEND 1 6 CO RIM: 692.61 INV OUT: 69.35 PIPES IN: FROM A2, 15 HDPE INV IN: 65.60 # 0.1 FROM A3, 12 HDPE INV IN: 67.33 # 0.1 FROM A5, 12 HDPE INV IN: 67.7 # 0.79 FROM A7, 6 HDPE INV IN: 6.90 # 0.79 PIPES OUT TO A1, 15 HDPE INV OUT: 67.0 # 0.1 TO A2, 12 HDPE INV OUT: 67.77 # 0.1 TO A3, 12 HDPE INV OUT: 6.40 # 0.79 TO A5, 6 HDPE INV OUT: 69.35 # 0.79This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCNORTH GRADING DRAINAGE PLANC03 WEEEWWWWWWW W W W W STOP STOPSTOPT T T T T T T E E E E E T TE TTTTT TTTT 10 P.R.L. 35 B.R.L.35 B.R.L.10 P.R.L.5 P.R.L.5 P.R.L.LODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODDA E2 0.55 AC CW 0.30 DA E3 0.20 AC CW 0.30 DA E5 0.14 AC CW 0.30 DA E1 0.21 AC CW 0.30 DA E4 0.06 AC CW 0.30 PRE OVERALL 1.16 AC CW 0.30 LEGEND LOD PROPERTY LINE PROPOSED LIMITS OF DISTURBANCE EXISTING CONTOURS PROPOSED CONTOURS IMPERVIOUS AREA DRAINAGE AREA BOUNDARY GENERAL NOTES 1.DRAINAGE AREAS ARE BASED ON THOSE IN THE RUTHERFORD CROSSING APPROVED PLAN SET DATED 10/11/2007. 1.1.SEE STORMWATER NARRATIVE ON SHEET C03.2 WEEEET WWWWWWW W W W W STOP STOPTT T T T T T E E E E E T TEE TTTTT TTTTT 10 P.R.L. 35 B.R.L.35 B.R.L.10 P.R.L.5 P.R.L.5 P.R.L.LODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLOD690 690 691 691692 692692 692 691 691LODLOD LODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODDA P2 0. AC CW 0.76 DA P5 0.02 AC CN 0.43 DA P1 0.17 AC CW 0.51 DA P4 0.03 AC CW 0.57 DA P3 0.06 AC CW 0.52 POST OVERALL 1.16 AC CW 0.70 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCDRAINAGE AREA MAPC03.1NORTH PRE-DEVELOPMENT POST-DEVELOPMENT This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCSTORMWATERMANAGEMENTNARRATIVEC03.2 STORMWATER MANAGEMENT NARRATIVE STORMWATER MANAGEMENT FOR THE RUTHERFORD CROSSING SHOPPING CENTER IS PROVIDED BY A WET SWALE NORTH OF THE PROPERTY. COUNTY STAFF HAS INDICATED THAT CHANNEL AND FLOOD PROTECTION FOR THIS PROJECT WILL BE MET AS LONG AS THE DISTURBED AREA INCLUDES LESS IMPERVIOUS COVER THAN ORIGINALLY DESIGNED IN THE RUTHERFORD CROSSING SITE PLAN DATED OCTOBER 11, 2007. THE ORIGINAL PLANS ASSUMED A RATIONAL COEFFICIENT OF 0. FOR THE DISTURBED AREA, WHILE THIS APPLICATION PROPOSES 0.70 SEE SHEET C03.1 . GIVEN THAT THIS IS LESS THAN DESIGNED, CHANNEL AND FLOOD PROTECTION RE4UIREMENTS ARE CONSIDERED MET. WATER QUALITY NARRATIVE THE PROPOSED DEVELOPMENT FLOWS EXCLUSIVELY TO THE DRAINAGE SYSTEM THAT IS PART OF THE SITE PLAN FOR RUTHERFORD CROSSING, DATED 10/11/2007. THE PROJECT WILL RE4UIRE A PHOSPHOROUS LOAD REDUCTION OF 0.65 LB/YR CALCULATED USING THE NEW DEVELOPMENT VIRGINIA RUNOFF REDUCTION METHOD COMPLIANCE SPREADSHEET - VERSION 4.1. THE ENTIRE 0.65 LB/YR OF RE4UIRED PHOSPHOROUS REDUCTION IS ACHIEVED THROUGH PURCHASE OF NUTRIENTS CREDITS. VIRGINIA RUNOFF REDUCTION CALCULATIONS WWW W W W W W W W W W WWWWWEEEEET WWWWWWW W W W W W STOP STOPSTOPEETT T T T T T T T E E E E E E T T TEE TTTTTT TTTTTT 10 P.R.L. 35 B.R.L.35 B.R.L.10 P.R.L.W5 P.R.L.5 P.R.L.690 690 691 691692 692692 692 691 691LODLOD LODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODSFSFSFSFSF SF SF SF SF SF IP PROPOSED SILT SOCK CONTRACTOR MAY REVISE CONSTRUCTION ENTRANCE LOCATION ELSEWHERE WITHIN THE PAD AT THE APPROVAL OF THE INSPECTOR SFSF SF SF SF CE CONTRACTOR TO INSTALL SILT FENCE ALONG PERIMETER OF PROPERTY AT CONSTRUCTION COMMENCEMENT. SILT FENCE TO BE REMOVED AS APPROPRIATE DURING FINE GRADING. IP IP IP SF FIRESTONE BUILDING ER PROTOTYPE “ 6,607 SF LEGEND LOD PROPERTY LINE PROPOSED LIMITS OF DISTURBANCE EXISTING CONTOURS SF PROPOSED SILT FENCE CONSTRUCTION ENTRANCE GENERAL NOTES 1.EROSION AND SEDIMENT CONTROL MEASURES TO REMAIN IN PLACE THROUGHOUT CONSTRUCTION. 2.EROSION CONTROL MEASURES ARE SHOWN OFFSET FROM THE LIMITS OF DISTURBANCE FOR CLARITY 3.REFER TO SHEET C04.1 FOR ESC NOTES AND SUGGESTED SE4UENCE OF CONSTRUCTION. SF CE PROPOSED INLET PROTECTIONIP This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCNORTH EROSION SEDIMENT CONTROLPLANC04 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCEROSION SEDIMENT CONTROLNOTESC04.1 SUGGESTED SE4UENCE OF CONSTRUCTION 1.CONTRACTOR TO OBTAIN ALL APPLICABLE PERMITS PRIOR TO COMMENCEMENT OF LAND DISTURBANCE ACTIVITIES. COPIES OF OBTAINED PERMITS ARE TO BE FILED WITH FREDERICK COUNTY. 2.CONTRACTOR TO STAKE OUT LIMITS OF DISTURBANCE. 3.UPON WRITTEN APPROVAL FROM INSPECTOR INSTALL SITE SEDIMENT CONTROLS AS SHOWN ON THE PLAN. NO CLEARING OR GRADING IS TO BE DONE EXCEPT WHERE NECESSARY FOR THE INSTALLATION OF PERIMETER SEDIMENT CONTROLS. MARK ALL PROTECTED AREAS PRIOR TO LAND DISTURBING ACTIVITY. 4.INSTALL SILT FENCE AS NOTED ON THE PLANS. 5.DEMOLISH AND REMOVE ALL FEATURES AS SHOWN ON THE DEMOLITION PLAN SHEET. HAUL DEBRIS TO AN APPROVED SITE. 4.BEGIN CLEARING AND ROUGH GRADING. 5.ANY DISTURBED AREAS THAT WILL REMAIN DORMANT FOR 7 DAYS SHALL BE TEMPORARY SEEDED. 6.INSPECT AND MAINTAIN/REPLACE SEDIMENT CONTROLS AS NECESSARY THROUGHOUT THE TIMELINE OF CONSTRUCTION. 7.BEGIN CONSTRUCTION OF PROPOSED STORM SYSTEM AND OTHER UTILITIES. PROVIDE INLET PROTECTION FOR ALL PROPOSED INLETS OF STORM SYSTEMS AS SHOWN ON PLANS. .BEGIN CONSTRUCTION OF PROPOSED AUTO CARE CENTER AND PARKING LOT. 9.UPON COMPLETION OF DEMOLITION, CONSTRUCTION AND LAND DISTURBING ACTIVITIES, PROVIDE PERMANENT STABILI=ATION ACCORDING TO APPROVED METHODS AND REMOVE ALL REMAINING EROSION AND SEDIMENT CONTROL MEASURES WITH APPROVAL OF INSPECTOR. PROJECT DESCRIPTION THE PROJECT CONSISTS OF IMPROVEMENTS ASSOCIATED WITH A NEW AUTO CARE CENTER TO BE LOCATED IN FREDERICK COUNTY, VIRGINIA, NEAREST TO THE INTERSECTION OF MERCHANT STREET AND MARKET STREET. THE SITE IS CURRENTLY VACANT AND IS =ONED AS B-3 INDUSTRIAL TRANSITION DISTRICT . PROPOSED IMPROVEMENTS INCLUDE A NEW /-6,607 SF BUILDING WITH A HEIGHT OF /-25 5, DRIVE AISLES, PARKING AREAS, CURBING, WATER SEWER CONNECTIONS, AND A STORM DRAINAGE NETWORK. SITE WORK INCLUDES GRADING, UTILITY INSTALLATIONS, PAVING, AND LANDSCAPING. THE PROPOSED LAND DISTURBANCE ENCOMPASSES /-1.16 ACRES. ACCESS TO THE SITE WILL BE PROVIDED VIA FOUR PROPOSED ENTRANCES OFF OF TWO EXISTING ACCESS DRIVES CONNECTED WITH MARKET STREET. EXISTING SITE CONDITIONS CURRENTLY, THE SITE IS A VACANT LOT. THE SITE IS LOCATED WITHIN AN EXISTING COMMERCIAL DEVELOPMENT KNOWN AS RUTHERFORD CROSSING. THE SITE IS RELATIVELY FLAT, WITH SLOPES DRAINING FROM THE MIDDLE OF THE SUBJECT AREA TO THE EXTENTS. THE SITE HAS AREAS OF EXISTING PAVEMENT AS WELL AS AREAS WITH VEGETATION. EROSION CONTROL MEASURES (C-ECM): C-ECM-15. OUTLET PROTECTION: OUTLET PROTECTION TAKES THE FORM OF STRUCTURALLY LINED APRONS OR OTHER FORMS OF ENERGY-DISSIPATING DEVICES PLACED AT THE OUTLETS OF PIPES, CURB OPENINGS, DITCH TURNOUTS, OR PAVED CHANNEL SECTIONS TO SLOW DISCHARGE VELOCITY FROM THE OUTLET TO PREVENT AN EROSIVE CONDITION. OUTLET PROTECTION PREVENTS SCOURING AT STORMWATER OUTLETS, PROTECTS THE OUTLET STRUCTURE, AND MINIMI=ES THE POTENTIAL FOR DOWNSTREAM EROSION BY REDUCING THE VELOCITY AND ENERGY OF CONCENTRATED STORMWATER FLOWS. OUTLET PROTECTION APPLIES TO THE OUTLETS OF ALL PIPES AND ENGINEERED CHANNEL SECTIONS. DISCHARGE VELOCITIES FROM PIPE OUTFALLS, OUTLET CHANNELS, OR SIMILAR STRUCTURES SHOULD NOT CAUSE EROSION IN DOWNSTREAM CHANNELS. SEDIMENT CONTROL MEASURES (C-SCM): C-SCM-03. TEMPORARY STONE CONSTRUCTION ENTRANCE: A TEMPORARY STONE CONSTRUCTION ENTRANCE IS A PAD WITH A FABRIC FILTER LINER UNDERNEATH THE STONE LOCATED AT POINTS OF VEHICULAR INGRESS AND EGRESS ON A CONSTRUCTION SITE. THERE ARE SEVERAL TYPES OF TRACK-OUT CONTROLS THAT MINIMI=E THE AMOUNT OF SEDIMENT, SUCH AS DIRT OR MUD, LEAVING OR BEING TRACKED OUT FROM THE CONSTRUCTION SITE ATTACHED TO VEHICLES. CONSTRUCTION ENTRANCES PROVIDE AN OPPORTUNITY FOR SIGNIFICANT REMOVAL OF MUD FROM CONSTRUCTION VEHICLE TIRES BEFORE THEY ENTER A PUBLIC ROAD, AND, JUST AS IMPORTANT, THE SOIL ADJACENT TO THE PAVED SURFACE CAN BE KEPT INTACT. TEMPORARY STONE CONSTRUCTION ENTRANCES REDUCE THE TRACKING OF MUD ONTO PAVED PUBLIC ROADS BY MOTOR VEHICLES OR RUNOFF AND PROVIDE A STABLE ENTRY TO OR EXIT FROM THE CONSTRUCTION SITE. THIS PRACTICE APPLIES WHERE TRAFFIC LEAVES A CONSTRUCTION SITE AND MOVES DIRECTLY ONTO A PUBLIC ROAD OR OTHER PAVED AREA. C-SCM-04. INLET PROTECTION: A SEDIMENT FILTER OR AN EXCAVATED IMPOUNDING AREA AROUND A STORM DRAIN DROP INLET OR CURB INLET WILL BE PROVIDED AT ALL INLET LOCATIONS WITHIN THE LIMITS OF DISTURBANCE. THE PURPOSE OF THIS PRACTICE IS TO PREVENT SEDIMENT FROM ENTERING STORM DRAINAGE SYSTEMS PRIOR TO PERMANENT STABILI=ATION OF THE DISTURBED AREA. THE STRUCTURE SHALL BE INSPECTED AFTER EACH RAIN AND REPAIRS MADE AS NEEDED. SEDIMENT SHALL BE REMOVED AND THE TRAP RESTORED TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE HALF THE DESIGN DEPTH OF THE TRAP. REMOVED SEDIMENT SHALL BE DEPOSITED IN A SUITABLE AREA AND IN SUCH A MANNER THAT IT WILL NOT ERODE. STRUCTURES SHALL BE REMOVED AND THE AREA STABILI=ED WHEN THE REMAINING DRAINAGE AREA HAS BEEN PROPERLY STABILI=ED. SURFACE STABILIZATION MEASURES (C-SSM): C-SSM-10. PERMANENT SEEDING: PERMANENT SEEDING IS THE ESTABLISHMENT OF PERENNIAL VEGETATIVE COVER ON DISTURBED AREAS BY PLANTING SEED. THE PURPOSES OF PERMANENT SEEDING ARE: 1.TO REDUCE EROSION AND DECREASE SEDIMENT YIELD FROM DISTURBED AREAS 2.TO PERMANENTLY STABILI=E DISTURBED AREAS IN A MANNER THAT IS ECONOMICAL, ADAPTABLE TO SITE CONDITIONS, AND ALLOWS SELECTION OF THE MOST APPROPRIATE PLANT MATERIALS 3.TO IMPROVE WILDLIFE HABITAT AND 4.TO ENHANCE NATURAL BEAUTY. PERMANENT SEEDING APPLIES IN: 1.DISTURBED AREAS WHERE PERMANENT, LONG-LIVED VEGETATIVE COVER IS NEEDED TO STABILI=E THE SOIL AND 2.ROUGH-GRADED AREAS THAT WILL NOT BE BROUGHT TO FINAL GRADE FOR 1 YEAR OR MORE. PERIMETER CONTROL MEASURES (C-PCM): C-PCM-04. SILT FENCE: A TEMPORARY SEDIMENT BARRIER CONSISTING OF A SYNTHETIC FILTER FABRIC STRETCHED ACROSS AND ATTACHED TO SUPPORTING POSTS AND ENTRENCHED WILL BE PROVIDED AROUND MUCH OF THE SITE PERIMETER AND PARALLEL TO SLOPED AREAS. THE PURPOSE OF THIS PRACTICE IS TO INTERCEPT AND DETAIN SMALL AMOUNTS OF SEDIMENT FROM DISTURBED AREAS DURING CONSTRUCTION OPERATIONS IN ORDER TO PREVENT SEDIMENT FROM LEAVING THE SITE. SILT FENCES SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY RE4UIRED REPAIRS SHALL BE MADE IMMEDIATELY. CLOSE ATTENTION SHALL BE PAID TO THE REPAIR OF DAMAGED SILT FENCE RESULTING FROM END RUNS AND UNDERCUTTING. SHOULD THE FABRIC ON A SILT FENCE DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE LIFE AND THE BARRIER STILL BE NECESSARY, THE FABRIC SHALL BE REPLACED PROMPTLY. SEDIMENT DEPOSITS SHOULD BE REMOVED AFTER EACH STORM EVENT. THEY MUST BE REMOVED WHEN DEPOSITS REACH APPROXIMATELY ONE-HALF THE HEIGHT OF THE BARRIER. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE IS NO LONGER RE4UIRED SHALL BE DRESSED TO CONFORM WITH THE EXISTING GRADE, PREPARED AND SEEDED. MINIMUM STANDARDS VSMH 5.3.1 AN EROSION AND SEDIMENT CONTROL PROGRAM ADOPTED BY A DISTRICT OR LOCALITY MUST BE CONSISTENT WITH THE FOLLOWING CRITERIA, TECHNI4UES AND METHODS: MS-1. STABILI=ATION: PERMANENT OF TEMPORARY SOIL STABILI=ATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILI=ATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN 14 DAYS. PERMANENT STABILI=ATION SHALL BE APPLIED TO AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN ONE YEAR. MS-2. STOCKPILES, WASTE, AND BORROW AREA: DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILES AND BORROW AREAS SHALL BE STABILI=ED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILI=ATION OF ALL SOIL STOCKPILES ON SITE AS WELL AS BORROW AREAS AND SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE. MS-3. PERMANENT VEGETATION: A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON DENUDED AREAS NOT OTHERWISE PERMANENTLY STABILI=ED. PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT, IS UNIFORM, MATURE ENOUGH TO SURVIVE AND WILL INHIBIT EROSION. MS-4. FIRST STEP MEASURES: SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND-DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. MS-5. EARTHEN STRUCTURE STABILI=ATION: STABILI=ATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES AND DIVERSION IMMEDIATELY AFTER INSTALLATION. MS-6. TRAPS AND BASINS: SEDIMENT TRAPS AND SEDIMENT BASINS SHALL BE DESIGNED AND CONSTRUCTED BASED UPON THE TOTAL DRAINAGE AREA TO BE SERVED BY THE TRAP OR BASIN. A.THE MINIMUM STORAGE CAPACITY OF A SEDIMENT TRAP SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA AND THE TRAP SHALL ONLY CONTROL DRAINAGE AREAS LESS THAN THREE ACRES. B.SURFACE RUNOFF FROM DISTURBED AREAS THAT IS COMPRISED OF FLOW FROM DRAINAGE AREAS GREATER THAN OR E4UAL TO THREE ACRES SHALL BE CONTROLLED BY A SEDIMENT BASIN. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT BASIN SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA. THE OUTFALL SYSTEM SHALL, AT A MINIMUM, MAINTAIN THE STRUCTURAL INTEGRITY OF THE BASIN DURING A TWENTY-FIVE YEAR STORM OF 24-HOUR DURATION. RUNOFF COEFFICIENTS USED IN RUNOFF CALCULATIONS SHALL CORRESPOND TO A BARE EARTH CONDITION OR THOSE CONDITIONS EXPECTED TO EXIST WHILE THE SEDIMENT BASIN IS UTILI=ED. MS-7. CUT AND FILL SLOPES: CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMI=E EROSION. SLOPES THAT ARE FOUND TO BE ERODING EXCESSIVELY WITHIN ONE YEAR OF PERMANENT STABILI=ATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE STABILI=ING MEASURES UNTIL THE PROBLEM IS CORRECTED. MS-. CONCENTRATED RUNOFF: CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADE4UATE TEMPORARY OR PERMANENT CHANNEL, FLUME OR SLOPE DRAIN STRUCTURE. MS-9. WATER SEEPS: WHENEVER WATER SEEPS FROM A SLOPE FACE, ADE4UATE DRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED. MS-10. INLET PROTECTION: ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT-LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. MS-11. OUTLET PROTECTION: BEFORE NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS OR PIPES ARE MADE OPERATIONAL, ADE4UATE OUTLET PROTECTION AND ANY RE4UIRED TEMPORARY OR PERMANENT CHANNEL LINING SHALL BE INSTALLED IN BOTH THE CONVEYANCE CHANNEL AND RECEIVING CHANNEL. MS-12. WATERCOURSE CONSTRUCTION: WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS SHALL BE TAKEN TO MINIMI=E ENCROACHMENT, CONTROL SEDIMENT TRANSPORT AND STABILI=E THE WORK AREA TO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NONERODIBLE MATERIAL SHALL BE USED FOR THE CONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE SUED FOR THESE STRUCTURES IF ARMORED BY NONERODIBLE COVER MATERIALS. MS-13. TEMPORARY VEHICULAR STREAM CROSSING: WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES MORE THAN TWICE IN ANY SIX-MONTH PERIOD, A TEMPORARY VEHICULAR STREAM CROSSING CONSTRUCTED OF NONERODIBLE MATERIAL SHALL BE PROVIDED. MS-14. OTHER WATERCOURSE REGULATIONS: ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS PERTAINING TO WORK IN OR CROSSING LIVE WATERCOURSES SHALL BE MET. MS-15. BED AND BANK STABILI=ATION: THE BED AND BANKS OF A WATERCOURSE SHALL BE STABILI=ED IMMEDIATELY AFTER WORK IN THE WATERCOURSE IS COMPLETED. MS-16. UTILITY CONSTRUCTION: UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: A.NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. B.EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. C.EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF-SITE PROPERTY. D.MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMI=E EROSION AND PROMOTE STABILI=ATION. E.RESTABILI=ATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THESE REGULATIONS. F.APPLICABLE SAFETY REGULATIONS SHALL BE COMPLIED WITH. MS-17. VEHICULAR TRACKING AND CONSTRUCTION ENTRANCES: WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMI=E THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SHALL APPLY TO INDIVIDUAL DEVELOPMENT LOTS AS WELL AS TO LARGER LAND-DISTURBING ACTIVITIES. MS-1. TEMPORARY CONTROL REMOVAL: ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILI=ATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORI=ED BY THE LOCAL PROGRAM AUTHORITY. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURE SHALL BE PERMANENTLY STABILI=ED TO PREVENT FURTHER EROSION AND SEDIMENTATION. MS-19. ADE4UATE STORMWATER CONVEYANCE TO ADE4UATE STORMWATER OUTFALL: PROPERTIES AND WATERWAYS DOWNSTREAM FROM DEVELOPMENT SITES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION, EROSION AND DAMAGE DUE TO INCREASE IN VOLUME, VELOCITY AND PEAK FLOW RATE OF STORMWATER RUNOFF FOR THE STATED FRE4UENCY STORM OF 24-HOUR DURATION IN ACCORDANCE WITH THE FOLLOWING STANDARDS AND CRITERIA: A.CONCENTRATED STORMWATER RUNOFF LEAVING A DEVELOPMENT SITE SHALL BE DISCHARGED DIRECTLY INTO AN ADE4UATE NATURAL OR MAN-MADE RECEIVING CHANNEL, PIPE OR STORM SEWER SYSTEM. FOR THOSE SITES WHERE RUNOFF IS DISCHARGED INTO A PIPE OR PIPE SYSTEM, DOWNSTREAM STABILITY ANALYSES AT THE OUTFALL OF THE PIPE OR PIPE SYSTEM SHALL BE PERFORMED. B.ADE4UACY OF ALL CHANNELS AND PIPES SHALL BE VERIFIED IN THE FOLLOWING MANNER: 1.THE APPLICANT SHALL DEMONSTRATE THAT THE TOTAL DRAINAGE AREA TO THE POINT OF ANALYSIS WITHIN THE CHANNEL IS ONE HUNDRED TIMES GREATER THAN THE CONTRIBUTING DRAINAGE AREA OF THE PROJECT IN 4UESTIONS 2.OR ·NATURAL CHANNELS SHALL BE ANALY=ED BY THE USE OF A TWO-YEAR STORM TO VERIFY THAT STORMWATER WILL NOT OVERTOP CHANNEL BANKS OR CAUSE EROSION OF CHANNEL BED OR BANKS AND ·ALL PREVIOUSLY CONSTRUCTED MAN-MADE CHANNELS SHALL BE ANALY=ED BY THE USE OF A TEN-YEAR STORM TO VERIFY THAT STORMWATER WILL NOT OVERTOP ITS BANKS AND BY THE USE OF A TWO-YEAR STORM TO DEMONSTRATE THAT STORMWATER WILL NOT CAUSE EROSION OF CHANNEL BED OR BANKS AND ·PIPES AND STORM SEWER SYSTEMS SHALL BE ANALY=ED BY THE USE OF A TEN-YEAR STORM TO VERIFY THAT STORMWATER WILL BE CONTAINED WITHIN THE PIPE OR SYSTEM. C.IF EXISTING NATURAL RECEIVING CHANNELS OR PREVIOUSLY CONSTRUCTED MAN-MADE CHANNELS OR PIPES ARE NOT ADE4UATE, THE APPLICANT SHALL: 1.IMPROVE THE CHANNEL TO A CONDITION WHERE A TEN-YEAR STORM WILL NOT OVERTOP THE BANKS AND A TWO-YEAR STORM WILL NOT CAUSE EROSION TO THE CHANNEL BED OR BANKS OR 2.IMPROVE THE PIPE OR PIPE SYSTEM TO A CONDITION WHERE THE TEN-YEAR STORM IS CONTAINED WITHIN THE APPURTENANCES OR 3.DEVELOP A SITE DESIGN THAT WILL NOT CAUSE THE PRE-DEVELOPMENT PEAK RUNOFF RATE FROM A TWO-YEAR STORM TO INCREASE WHEN RUNOFF OUTFALLS INTO A NATURAL CHANNEL OR WILL NOT CAUSE THE PRE-DEVELOPMENT PEAK RUNOFF RATE FROM A TEN-YEAR STORM TO INCREASE WHEN RUNOFF OUTFALLS INTO A MAN-MADE CHANNEL OR 4.PROVIDE A COMBINATION OF CHANNEL IMPROVEMENT, STORMWATER DETENTION OR OTHER MEASURES WHICH IS SATISFACTORY TO THE PLAN-APPROVING AUTHORITY TO PREVENT DOWNSTREAM EROSION. D.THE APPLICANT SHALL PROVIDE EVIDENCE OF PERMISSION TO MAKE THE IMPROVEMENTS. E.ALL HYDROLOGIC ANALYSES SHALL BE BASED ON THE EXISTING WATERSHED CHARACTERISTICS AND THE ULTIMATE DEVELOPMENT OF THE SUBJECT PROJECT. F.IF THE APPLICANT CHOOSES AN OPTION THAT INCLUDES STORMWATER DETENTION HE SHALL OBTAIN APPROVAL FROM THE LOCALITY OF A PLAN FOR MAINTENANCE OF THE DETENTION FACILITIES. THE PLAN SHALL SET FORTH THE MAINTENANCE RE4UIREMENTS OF THE FACILITY AND THE PERSON RESPONSIBLE FOR PERFORMING THE MAINTENANCE. G.OUTFALL FROM A DETENTION FACILITY SHALL BE DISCHARGED TO A RECEIVING CHANNEL, AND ENERGY DISSIPATERS SHALL BE PLACED AT THE OUTFALL OF ALL DETENTION FACILITIES AS NECESSARY TO PROVIDE A STABILI=ED TRANSITION FROM THE FACILITY TO THE RECEIVING CHANNEL. H.ALL ON-SITE CHANNELS MUST BE VERIFIED TO BE ADE4UATE. I. INCREASED VOLUMES OF SHEET FLOWS THAT MAY CAUSE EROSION OR SEDIMENTATION ON ADJACENT PROPERTY SHALL BE DIVERTED TO A STABLE OUTLET, ADE4UATE CHANNEL, PIPE OR PIPE SYSTEM, OR TO A DETENTION FACILITY. J.IN APPLYING THESE STORMWATER RUNOFF CRITERIA, INDIVIDUAL LOTS OR PARCELS IN A RESIDENTIAL, COMMERCIAL OR INDUSTRIAL DEVELOPMENT SHALL NOT BE CONSIDERED TO BE SEPARATE DEVELOPMENT PROJECTS. INSTEAD, THE DEVELOPMENT, AS A WHOLE, SHALL BE CONSIDERED TO BE A SINGLE DEVELOPMENT PROJECT. HYDROLOGIC PARAMETERS THAT REFLECT THE ULTIMATE DEVELOPMENT CONDITION SHALL BE USED IN ALL ENGINEERING CALCULATIONS. K.ALL MEASURES USED TO PROTECT PROPERTIES AND WATERWAYS SHALL BE EMPLOYED IN A MANNER WHICH MINIMI=ES IMPACTS ON THE PHYSICAL, CHEMICAL AND BIOLOGICAL INTEGRITY OF RIVERS, STREAMS AND OTHER WATERS OF THE STATE. STORMWATER MANAGEMENT THE ENTIRETY OF THE SITE'S STORMWATER IS FLOWING TO VARIOUS EXISTING INLETS THAT TIE INTO AN EXISTING STORMWATER MANAGEMENT FACILITY PER THE APPROVED RUTHERFORD CROSSING SHOPPING CENTER PLANS. MAINTENANCE BETWEEN THE TIME THE EROSION CONTROL PLAN IS IMPLEMENTED AND FINAL SITE STABILI=ATION IS ACHIEVED, ALL DISTURBED AREAS AND EROSION CONTROLS MUST BE INSPECTED NOT LESS THAN ONCE EVERY SEVEN 7 CALENDAR DAYS AND WITHIN 4 HOURS OF A RUNOFF PRODUCING RAINFALL EVENT. EXAMPLES OF PARTICULAR ITEMS TO BE EVALUATED DURING SITE INSPECTIONS ARE LISTED BELOW. THIS LIST IS NOT INTENDED TO BE COMPREHENSIVE. DURING EACH INSPECTION, EACH INSPECTOR MUST EVALUATE OVERALL EROSION CONTROL SYSTEM PERFORMANCE, AS WELL AS THE EFFECTIVENESS OF SYSTEM COMPONENTS. ADDITIONAL FACTORS SHOULD BE CONSIDERED AS APPROPRIATE TO THE CIRCUMSTANCES. ·LOCATIONS WHERE VEHICLES ENTER AND EXIT THE SITE MUST BE INSPECTED FOR EVIDENCE OF OFF-SITE SEDIMENT TRACKING. A STABILI=ED CONSTRUCTION ENTRANCE WILL BE CONSTRUCTED WHERE VEHICLES ENTER AND EXIT. THIS ENTRANCE WILL BE MAINTAINED OR SUPPLEMENTED AS NECESSARY TO PREVENT SEDIMENT FROM LEAVING THE SITE ON VEHICLES. SEDIMENT TRACKED ONTO PUBLIC ROADWAYS MUST BE SHOVELED OR SWEPT FROM THE ROADWAY AND RE-DEPOSITED ON SITE IN A MANNER THAT MINIMI=ES ITS OFFSITE RELEASE POTENTIAL. ·SEDIMENT BARRIERS MUST BE INSPECTED AND, IF NECESSARY, THEY MUST BE ENLARGED OR CLEANED IN ORDER TO PROVIDE ADDITIONAL CAPACITY. ALL MATERIAL EXCAVATED FROM BEHIND SEDIMENT BARRIERS SHALL BE STOCKPILED ON THE UP SLOPE SIDE OF THE BARRIER. ADDITIONAL SEDIMENT BARRIERS MUST BE CONSTRUCTED AS NEEDED. ·INSPECTIONS WILL EVALUATE DISTURBED AREAS AND AREAS USED FOR STORING MATERIALS THAT ARE EXPOSED TO RAINFALL FOR EVIDENCE OF, OR THE POTENTIAL FOR, POLLUTANTS ENTERING THE DRAINAGE SYSTEM. IF NECESSARY, THE MATERIALS MUST BE COVERED OR ORIGINAL COVERS MUST BE REPAIRED OR SUPPLEMENTED. ALSO, PROTECTIVE BERMS MUST BE CONSTRUCTED, IF NEEDED, IN ORDER TO CONTAIN RUNOFF FROM MATERIAL STORAGE AREAS. ·GRASSED AREAS WILL BE INSPECTED TO CONFIRM THAT A HEALTHY STAND OF GRASS IS MAINTAINED. THE SITE HAS ACHIEVED FINAL STABILI=ATION WHEN TURF GRASS COVER PROVIDES PERMANENT STABILI=ATION OF THE SOIL SURFACE EXCLUSIVE OF AREAS THAT HAVE BEEN PAVED OR COVERED BY BUILDING S . PERMANENT STABILI=ATION IS NOT CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT IS UNIFORM, MATURE ENOUGH TO SURVIVE AND WILL INHIBIT EROSION. ·ALL DISCHARGE POINTS MUST BE INSPECTED TO DETERMINE WHETHER EROSION CONTROL MEASURES ARE EFFECTIVE IN PREVENTING IMPACTS TO RECEIVING WATERS. BASED UPON THE RESULTS OF THE INSPECTIONS, EACH EROSION AND SEDIMENT CONTROL MEASURE SHALL BE REPAIRED AND/OR MAINTAINED IN ACCORDANCE WITH THE MAINTENANCE RE4UIREMENTS SPECIFIED IN THE CORRESPONDING SECTION OF VIRGINIA STORMWATER MANAGEMENT HANDBOOK VSMH MAINTAINED BY VIRGINIA S DEPARTMENT OF ENVIRONMENTAL 4UALITY DE4 . THE CONTRACTOR SHALL MAINTAIN A COPY OF THIS HANDBOOK ON SITE AT ALL TIMES DURING CONSTRUCTION. PERMANENT STABILI=ATION PERMANENT STABILI=ATION WILL BE ACHIEVED WITH SEEDING AS SHOWN ON THE LANDSCAPING AND EROSION CONTROL PLAN SHEETS FOR ALL VEGETATED OR LANDSCAPING AREAS. CONCRETE, PAVEMENT AND OTHER IMPERVIOUS SURFACES WILL STABILI=E THE REMAINDER OF THE SITE. REF. SECTION 5.3.1.1 MS-1: STABILI=ATION . STOCKPILING TOPSOIL SHALL BE STOCKPILED IN SUCH A MANNER THAT NATURAL DRAINAGE IS NOT OBSTRUCTED AND NO OFF-SITE SEDIMENT DAMAGE SHALL RESULT. STABILI=E OR PROTECT STOCKPILES IN ACCORDANCE WITH MINIMUM STANDARD 2 MS-2 . THE SIDE SLOPES OF THE STOCKPILE SHALL NOT EXCEED 2H:1V. PERIMETER CONTROLS MUST BE PLACED AROUND THE STOCKPILE IMMEDIATELY SEEDING OF STOCKPILES SHALL BE COMPLETED WITHIN 7 DAYS OF THE FORMATION OF THE STOCKPILE, IN ACCORDANCE WITH STD. AND 5.3.1.1 MS-1: STABILI=ATION TEMPORARY SEEDING . IF IT IS TO REMAIN DORMANT FOR LONGER THAN 30 DAYS. REFER TO MINIMUM STANDARD 1 MS-1 AND 2 MS-2 UNDER 5.3.1 EROSION AND SEDIMENT CONTROL MINIMUM STANDARDS VSMH . TEMPORARY STABILI=ATION TEMPORARY STABILI=ATION SHOULD BE USED WHERE SOIL SURFACES ARE NOT TO BE FINE GRADED FOR PERIODS LONGER THAN FOURTEEN 14 DAYS. SUCH AREAS INCLUDE DENUDED ARES, SOIL STOCKPILES, DIKES, DAMS, SIDES OF SEDIMENT BASINS, TEMPORARY ROADBANK, ETC. A PERMANENT VEGATIVE COVER SHALL BE APPLIED TO AREAS THAT WILL BE LEFT DORMANT FOR MORE THAN 1 YEAR. SPECIFICATIONS 3.31 OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK SHALL BE FOLLOWED FOR TEMPORARY STABILI=ATION. SE4UENCE OF CONSTRUCTION CLARIFICATION NOTE: THE SE4UENCE OF CONSTRUCTION SHOWN ABOVE IS A GENERAL OVERVIEW AND IS INTENDED TO CONVEY THE GENERAL CONCEPTS OF THE EROSION CONTROL DESIGN AND SHOULD NOT BE RELIED UPON FOR CONSTRUCTION PURPOSES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DETAILED PHASING AND CONSTRUCTION SE4UENCING NECESSARY TO CONSTRUCT THE PROPOSED IMPROVEMENTS INCLUDED IN THESE PLANS. THE CONTRACTOR SHALL NOTIFY ENGINEER IN WRITING IMMEDIATELY, PRIOR TO AND/OR DURING CONSTRUCTION IF ANY ADDITIONAL INFORMATION ON THE CONSTRUCTION SE4UENCE IS NECESSARY. CONTRACTOR IS SOLELY RESPONSIBLE FOR COMPLYING WITH THE RE4UIREMENTS OF THE AUTHORITY HAVING JURISDICTION AND ALL OTHER APPLICABLE LAWS. ADJACENT AREAS THE SITE IS BORDERED TO THE NORTH BY MARKET STREET, TO THE EAST BY A SPRINGHILL SUITES BY MARRIOTT, TO THE SOUTH BY MARTINSBURG PIKE, AND TO THE WEST BY AN URGENT CARE AND FAMILY PRACTICE CLINIC. THERE ARE NO STREAMS, LAKES, FLOODPLAIN AREAS, OR ENVIRONMENTAL 4UALITY CONCERNS ON THIS SITE. PERIMETER CONTROLS WILL PROTECT ADJACENT PROPERTIES. OFF-SITE AREAS NO OFF-SITE LAND DISTURBANCE IS PROPOSED WITH THIS PROJECT. SOILS THE SITE GENERALLY CONSISTS OF SOILS THAT ARE CLASSIFIED IN HYDROLOGIC SOIL GROUP C . SEE GEOTECHNICAL EVALUATION DATED 09/19/2025 FOR SOIL CHARACTERISTICS, BOUNDARIES, AND SITE GEOLOGY. WETLANDS THERE ARE NO EXISTING WETLANDS ON THE PROPOSED SITE. CONSTRUCTION ENTRANCE SITE ACCESS WILL BE PROVIDED VIA A PROPOSED CONSTRUCTION ENTRANCE LOCATED AT THE PROPOSED ENTRANCE ON THE NORTHEASTERN PORTION OF THE SITE. CONTROL MEASURES THE FOLLOWING CONTROL MEASURES, AS SHOWN ON THE EROSION CONTROL PLAN SHEETS: C04 OF THIS SITE PLAN, WILL BE USED FOR THIS PROJECT: CRITICAL AREAS CRITICAL AREAS TYPICALLY INCLUDE AREAS OF STEEP SLOPES, AREAS ADJACENT TO WETLANDS, AND OTHER AREAS WITH SERIOUS EROSION POTENTIAL. NO CRITICAL AREAS HAVE BEEN IDENTIFIED ON-SITE. CONTRACTOR SHALL OBTAIN A LAND DISTURBANCE/ VSMP PERMIT FROM FREDERICK COUNTY PUBLIC WORKS DEPARTMENT PRIOR TO COMMENCING ANY LAND DISTURBING ACTIVITIES. A COPY OF THE CONTRACTOR S STORMWATER POLLUTION PREVENTION PLAN SHALL BE INCLUDED WITH THE APPLICATION FOR THE PUBLIC WORKS PERMIT. This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCEROSION SEDIMENT CONTROLDETAILSC04.2 CONTRACTOR SHALL OBTAIN A LAND DISTURBANCE/ VSMP PERMIT FROM FREDERICK COUNTY PUBLIC WORKS DEPARTMENT PRIOR TO COMMENCING ANY LAND DISTURBING ACTIVITIES. A COPY OF THE CONTRACTOR S STORMWATER POLLUTION PREVENTION PLAN SHALL BE INCLUDED WITH THE APPLICATION FOR THE PUBLIC WORKS PERMIT. LEGEND S W LOD PROPERTY LINE PROPOSED LIMITS OF DISTURBANCE PROPOSED SANITARY SEWER PROPOSED WATER LINE 10 UTILITY EASEMENT 1.FINAL BUILDING CONNECTIONS FOR ALL UTILITIES TO BE COORDINATED WITH MEP TEAM. 2.WATER AND SEWER LINES SHALL TERMINATE 5 FROM THE BUILDING FOR SERVICE CONNECTIONS UNLESS NOTED OTHERWISE. 3.ALL PVC SANITARY SEWER PIPES TO BE PVC DR25 CONFORMING TO AWWA C900 UNLESS OTHERWISE NOTED. 4.CONTRACTOR TO CONFIRM SI=E OF ALL EXISTING UTILITIES. 5.FREDERICK WATER¶S WATER AND SEWER STANDARDS AND SPECIFICATIONS ARE AVAILABLE AT WWW.FREDERICKWATER.COM 6.THE CONTRACTOR SHALL ADHERE TO FREDERICK WATER STANDARDS AND SPECIFICATIONS IN EFFECT AT THE TIME OF CONSTRUCTION. 7.THE CONTRACTOR SHALL SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE FREDERICK WATER INSPECTOR PRIOR TO COMMENCING INSTALLATION OF ANY WATER OR SEWER FACILITIES. CONTRACTOR SHALL ALSO ARRANGE FOR INSPECTION OF SAID FACILITIES BY FREDERICK WATER. OIL WATER SEPARATORS AND/OR GREASE TRAPS MAY BE RE4UIRED BY FREDERICK COUNTY BUILDING INSPECTIONS. BOTH FREDERICK COUNTY BUILDING INSPECTIONS AND FREDERICK WATER WILL INSPECT THE INSTALLATION OF THOSE FACILITIES. BOTH INSPECTIONS SHALL BE SCHEDULED BY CONTRACTOR. .THE CONTRACTOR SHALL CONNECT A NEW SEWER LINE TO AN EXISTING MANHOLE BY CORE DRILLING THE MANHOLE. 9.A NEW WATER OR FORCED SEWER MAIN SHALL BE CONNECTED TO AN EXISTING MAIN BY A A CUT-IN TEE WITH ACCOMPANYING VALVES. 10.EXACT LOCATIONS OF WATER AND SEWER SERVICES ON NEW LINES ARE TO BE COORDINATED WITH FREDERICK WATER¶S INSPECTOR. 10.1.ADJUST FREDERICK WATER FACILITIES TO GRADE AS RE4UIRED BY THE FREDERICK WATER INSPECTOR. 11.FREDERICK WATER¶S MAINTENANCE DIVISION SHALL FURNISH AND INSTALL ALL WATER METERS THROUGH 2 INCH IN SI=E. IT IS THE CONTRACTOR¶S RESPONSIBILITY TO HAVE THE METER BOX ASSEMBLY INSTALLED CORRECTLY. BEFORE A PERMANENT METER IS INSTALLED: 11.1.THE METER BOX, WITH ITS FRAME AND COVER, MUST BE PROPERLY ALIGNED WITH THE YOKE BAR. 11.2.THE FRAME AND COVER SHALL BE SET TO FINAL GRADE. 11.3.THE DISTANCE BETWEEN THE TOP OF THE COVER AND THE YOKE BAR SHALL BE BETWEEN 20 AND 23 INCHES. 11.4.ALL COMPONENTS OF THE METER BOX ASSEMBLY SHALL BE IN PROPER WORKING ORDER. 12.FOR SERVICES THAT CONNECT TO EXISTING LINES: 12.1.FREDERICK WATER SHALL FURNISH AND INSTALL: 12.1.1.ALL ǫ´Xô´, ô´, 1´, 1ò´ AND 2´ WATER SERVICES 12.1.2.ALL SEWER SERVICES. 12.2.THE OWNER/DEVELOPER SHALL: 12.2.1.COORDINATE OR HAVE THE CONTRACTOR COORDINATE THE LOCATION OF THE SERVICE LATERAL WITH FREDERICK WATER¶S ENGINEERING ASSISTANT. 12.2.2.SUBMIT AN APPLICATION FOR SERVICE AND PAY THE RE4UIRED FEES. 13.ALL WATER SERVICE LINES MUST HAVE A BACKFLOW PREVENTION ASSEMBLY DOUBLE CHECK VALVE OR RP=, AS RE4UIRED . THE ASSEMBLY MUST MEET ASSE STANDARD NUMBER 1015 OR 1013. 14.ALL FIRE LINES MUST HAVE A BACKFLOW PREVENTION ASSEMBLY DETECTOR DOUBLE CHECK VALVE OR RP=, AS RE4UIRED . THE ASSEMBLY SHALL MEET ASSE STANDARD NUMBER 104 OR 1047. ANY PRIVATELY OWNED FIRE LINE, INTERIOR OR EXTERIOR, SHALL ALSO HAVE A FIRE SERVICE METER. THIS ASSEMBLY SHALL BE INSTALLED IMMEDIATELY BEFORE THE BACKFLOW PREVENTION UNIT. RADIO READ REMOTES ARE RE4UIRED. 15.FREDERICK WATER SHALL REVIEW THE MECHANICAL PLAN S FOR DESIGN AND MATERIAL APPROVAL OF A BUILDING¶S: 15.1.DOMESTIC WATER METER AND ITS BACKFLOW PREVENTION DEVICE, AND/OR ITS 15.2.FIRE SERVICE LINE¶S WATER METER AND BACKFLOW PREVENTION DEVICE. 16.DE4 MUST ALSO APPROVE SEWER PUMP STATIONS. FREDERICK WATER RE4UIRES A COPY OF DE4¶S CERTIFICATE TO OPERATE AND A COPY OF THE STATION¶S DE4 APPROVED O M MANUAL. THESE DOCUMENTS MUST BE RECEIVED BEFORE SUBSTANTIAL COMPLETION IS ISSUED AND WATER METERS RELEASED. 17.VALVES, MANHOLES, ARV S AND OTHER FREDERICK WATER SURFACE FEATURES SHALL NOT BE PLACED IN CURB AND GUTTER, NOR SLOPED PORTION OF HANDICAPPED RAMPS. CONTRACTOR SHALL COORDINATE LOCATIONS WITH THE FREDERICK WATER INSPECTOR. 1.IRRIGATION LINES AND DEVICES, LIGHT POLES, TRANSFORMERS, JUNCTION BOXES, PEDESTALS, OTHER OBSTACLES AND ALL DRY UTILITIES SHALL NOT BE PLACED ON FREDERICK WATER EASEMENTS. PERPENDICULAR IRRIGATION LINES AND DRY UTILITY CROSSINGS ARE PERMITTED WITH 1 MINIMUM VERTICAL SEPARATION AND PLACED IN CONDUIT OR SLEEVE WITHIN THE FREDERICK WATER EASEMENT SHOWN AND LABELED ON PLANS AND PROFILES. 19.RETAINING WALLS AND THEIR TIE BACKS SUCH AS GEO GRID OR OTHER SUPPORTS SHALL NOT BE PLACED IN FREDERICK WATER EASEMENTS. 20.CONTRACTOR SHALL TEST PIT AS RE4UIRED AND ADJUST ALL EXISTING FREDERICK WATER FACILITIES TO GRADE PER THE FREDERICK WATER INSPECTORS RE4UIREMENTS. 21.IF EXISTING FREDERICK WATER FACILITIES ARE REMOVED, THE REMOVED ITEMS AND RELATED MATERIALS SHALL BE REPLACED WITH NEW MATERIALS. REMOVED MATERIALS SHALL BE FURNISHED TO THE FREDERICK WATER INSPECTOR. 22.FIRE AND/OR DOMESTIC RISER METER, BACKFLOW DEVICES, ASSOCIATED VALVES AND PIPING SHALL BE PER THE FREDERICK WATER INSPECTOR, FREDERICK COUNTY FIRE MARSHAL AND FREDERICK COUNTY INSPECTION DEPARTMENT RE4UIREMENTS PROPOSED STORM STRUCTURE PROPOSED STORM PIPE GENERAL NOTES UGE PROPOSED ELECTRIC LINE GAS GAS PROPOSED GAS LINE UGE PROPOSED UNDERGROUND ELECTRIC LINE WWW W W W W W W W W W WWWWWEEEEET WWWWWWW W W W W W STOP STOPSTOPEETT T T T T T T T E E E E E E T T TEE TTTTTT TTTTTT 10 P.R.L. 35 B.R.L.35 B.R.L.10 P.R.L.W5 P.R.L.5 P.R.L.LODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODGAS BUILDING CONNECTION SANITARY BUILDING CONNECTION GASUGEUGEU G E UGE UGE UGE UGE UGE UGE UGE UGE UGE UGEUGEUGEUGEUGEWSWWWW OIL/ WATER SEPARATOR. SEE PLUMBING AND ARCHITECTURAL DRAWINGS FOR DETAIL. S04 S03 S02 S01 2 LF OF 6 PVC # 2.50 27 LF OF 6 PVC # 2.50  LF OF 4 PVC # 2.0 4 LF OF 4 PVC # 2.0 12 LF OF 4 PVC # 2.0 STA: 1000.92  COM. FIRE/DOM CONNECTION STA: 1041.46 CORP. STOP STA: 1041.44 1 200 PSI CTS POLYETHELENE TUBING AND 3/4 IRRIGATION METER W/ BACKFLOW PREVENTER STA: 1064.06  MJ 45ƒ BEND STA: 106.63  X  CUT-IN TEE 2  MJ GV 2 MJ LONG SOLID SLEEVES CONTRACTOR TO COMPLETE S05 FIRESTONE BUILDING ER PROTOTYPE “ 6,607 SF ELECTRIC AND TELECOM BUILDING CONNECTION PRIVATE IRRIGATION TO BE DESIGNED UNDER SEPARATE COVER STA: 1011.92  MJ GV W/ ROADWAY BOX SEE WATER MAIN CONNECTION/DISCONNECTION NOTES ON SHEET C02 FDC INSTALLED ON EXTERIOR OF BUILDING 1.00 9.00 1.00 END OF FREDERICK WATER 20 EASEMENT PRIVATEOWNERSHIPADDITIONAL GATE VALVE RE4UIRED AT MAIN FOR RISER PRIVATE OWNERSHIPFREDERICKWATERPROPOSED FIRE HYDRANT WITH BOLLARDS IRRIGATION LINES, CONTROL WIRES, ETC. THAT CROSS FW EASEMENTS SHALL HAVE MIN. 1 VERTICAL SEPARATION AND BE PLACED WITHIN CONDUIT THROUGH ENTIRE FW EASEMENT STA: 103.64 6 X  TEE 6 MJ GV  DI CL 52 WATER LINEFREDERICK WATER10 FREDERICK WATER EASEMENT INSTALL: -1 DOMESTIC METER -BACKFLOW PREVENTER -6 HP PROTECTUS III STAINLESS STEEL FIRE METER STRUCTURE TABLE STRUCTURE NAME: EX MH1 S01 S02 S03 S04 S04.1-IN S04.1-OUT S05 DETAILS: MH RIM: 692.24 INV IN: 62.95 MH RIM: 692.16 INV IN: 63.55 INV OUT: 63.35 6 SSCO RIM: 692.20 INV IN: 64.44 INV OUT: 64.24 MH RIM: 692.35 INV IN: 67.60 INV OUT: 65.14 6 SSCO RIM: 692.1 INV IN: 6.25 INV OUT: 6.05 OIL/WATER SEPARATOR IN RIM: 6.33 INV IN: 67.96 OIL/WATER SEPARATOR OUT RIM: 6.13 INV OUT: 67.76 BUILDING CONNECTION RIM: 6.7 INV OUT: 6.50 PIPES IN: FROM S01, 6 PVC INV IN: 62.95 # 0.95 FROM S02, 6 PVC INV IN: 63.55 # 2.50 FROM S03, 6 PVC INV IN: 64.44 # 2.50 FROM S04.1-OUT, 4 PVC INV IN: 67.60 # 2.0 FROM S05, 4 PVC INV IN: 6.25 # 2.0 FROM S04, 4 PVC INV IN: 67.96 # 2.0 PIPES OUT TO EX MH1, 6 PVC INV OUT: 63.35 # 0.95 TO S01, 6 PVC INV OUT: 64.24 # 2.50 TO S02, 6 PVC INV OUT: 65.14 # 2.50 TO S04.1-IN, 4 PVC INV OUT: 6.05 # 2.0 TO S03, 4 PVC INV OUT: 67.76 # 2.0 TO S04, 4 PVC INV OUT: 6.50 # 2.0 1.TANK SECTIONS SHALL BE BOLTED TOGETHER 2.WATERTIGHT BOLT DOWN FRAME AND COVERS ARE RE4UIRED 3.PENETRATIONS SHALL HAVE BOOTS 4.TANK, COMPONENTS, AND INSTALLATION SHALL BE TRAFFIC RATED 5.CONTRACTOR SHALL COORDINATE INSTALLATION AND INSPECTIONS WITH BOTH FREDERICK COUNTY INSPECTIONS DEPARTMENT AND FREDERICK WATER. OIL WATER SEPARATOR NOTES This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCUTILITY PLANC05NORTH SANITARY LATERAL SCALE: 1 40 H 1 4 V 676 60 64 6 692 696 700 704 70 712 716 720 676 60 64 6 692 696 700 704 70 712 716 720 27 LF OF 6 PVC # 2.50  LF OF 4 PVC # 2.0 4 LF OF 4 PVC # 2.0 12 LF OF 4 PVC # 2.0 EXISTING GRADE PROPOSED GRADE STA: 1070.066 SSCORIM: 692.20INV IN: 64.44 FROM S03 INV OUT: 64.24 TO S01 S02 STA: 109.15MHRIM: 692.35INV IN: 67.60 FROM S04.1-OUT INV OUT: 65.14 TO S02 S03 STA: 1120.566 SSCORIM: 692.1INV IN: 6.25 FROM S05 INV OUT: 6.05 TO S04.1-IN S04 970 1000692.21100693.2692.331150STA: 1042.69MHRIM: 692.16INV IN: 63.55 FROM S02 INV OUT: 63.35 TO EX MH1 S01 .03 OIL/ WATER SEPARATOR W/ CONCRETE COLLAR AND HEAVY DUTY LID STA: 1132.75BUILDING CONNECTIONRIM: 6.7INV OUT: 6.50 TO S04 S05 2 LF OF 6 PVC # 2.503.67 43 LF OF 6 PVC # 0.95STA: 1000MHRIM: 692.24INV IN: 62.95 FROM S01 EX MH1 LIMITS OF PRIVATE OWNERSHIP BEGINNING OF FREDERICK WATER OWNERSHIP 8-INCH COMBINED DOMESTIC AND FIRE SERVICE SCALE: 1 40 H 1 4 V 62 64 6 692 696 62 64 6 692 696 EXISTING GRADE PROPOSED GRADE 920 1000693.3692.5011001115 STA: 106.63  X  CUT-IN TEE 2  MJ GV 2 MJ LONG SOLID SLEEVES CONTRACTOR TO COMPLETE STA: 1064.06  MJ 45ƒ BEND STA: 1041.46 CORP. STOP STA: 1000.92  COM. FIRE/DOM CONNECTION 5.0 1.50 12 HDPE STORM INV: 6.13 STA: 1007.39 STA: 1011.92  MJ GV W/ ROADWAY BOX  DI CL 52 WAT E R L I N E LIMITS OF PRIVATE OWNERSHIP BEGINNING OF FREDERICK WATER OWNERSHIP TP CONTRACTOR TO TEST PIT TO CONFIRM TIE-IN ELEVATION OF EXISTING WATER LINE STA: 103.64 6 X  TEE 6 MJ GV INSTALL: -1 DOMESTIC METER -BACKFLOW PREVENTER -6 HP PROTECTUS III STAINLESS STEEL FIRE METER A1 TO A7 SCALE: 1 40 H 1 4 V 60 64 6 692 696 700 704 60 64 6 692 696 700 704 12 LF OF 15 HDPE # 0.1 EXISTING GRADE PROPOSED GRADE 2.54 STA: 1007.20VDOT DI-1RIM: 69.30INV IN: 65.60 15 S A1 STA: 11.95VDOT DI-3C L 6 RIM: 691.36INV IN: 67.33 12 NE INV OUT: 67.0 15 N A2 1000690.91100690.691.611200693.7691.341300693.3691.51390STA: 1242.69NYLOPLAST 24 BASIN SOLID COVER RIM: 692.36INV IN: 67.7 12 NE INV OUT: 67.77 12 SW A3 STA: 1310.7VDOT DI-3C L 6 RIM: 691.7INV IN: 6.90 6 NE INV OUT: 6.40 12 SW A5 54 LF OF 12 HDPE # 0.1 6 LF OF 12 HDPE # 0.791.50 57 LF OF 6 HDPE # 0.79STA: 1367.76 2 45ƒ BEND 1 6 CORIM: 692.61INV OUT: 69.35 6 SW A7  DIP WATER INV: 65.92 STA: 1276.43 10-YR HGL This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCWATER PROFILES SANITARY PROFILES STORM PROFILES DRAINAGE UTILITYPROFILESC05.1 WWW W W W W W W W W W WWWWWT WWWWWWW W W W W W STOP STOPSTOPEETT T T T T T T T E E E E E E T T TEE TTTTTT TTTTTT 10 P.R.L. 35 B.R.L.35 B.R.L.10 P.R.L.W5 P.R.L.5 P.R.L.GASUGEUGEU G E UGE UGE UGE UGE UGE UGE UGE UGE UGE UGEUGEUGEUGEUGEWSWWWW 19  4 LODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLOD1 GK 1 GK 1 GK 2 CC2 CC 3 CC 1 CC 4 CC 6 TCU 4 TCU 17 TCU 11 TCU FIRESTONE BUILDING ER PROTOTYPE “ 6,607 SF SYMBOL CODE 4TY BOTANICAL NAME COMMON NAME CONT CAL / HT TREES GK 3 Gymnocladus dioicus KentucNy Coffeetree B B 1.25Cal PLANT SCHEDULE INTERIOR LANDSCAPING SYMBOL CODE 4TY BOTANICAL NAME COMMON NAME CONT CAL / HT TREES CC 12 Cercis canadensis Eastern Redbud B B 1.25 Cal. Min. SYMBOL CODE 4TY BOTANICAL NAME COMMON NAME CONT HEIGHT SHRUBS TCU 3Ta[us cuspidata Japanese Yew Cont.3C HT. CODE 4TY BOTANICAL NAME COMMON NAME CONT GROUND COVERS SOD 3,934 sf - - - - - -Sod 2 gal PLANT SCHEDULE PERIMETER LANDSCAPING SOD 9,925 SF HYDROSEED 5,355 SF MULCH 1,93 SF This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCNORTH LANDSCAPE PLANL07 WWLWWLABENOTES: 1.NO TREES OR SHRUBS SHALL BE PLACED IN FW EASEMENTS. 2.NO TREES SHALL BE CLOSER THAN THREE 3 FEET TO EDGE OF SIDEWALKS, CURB, OR OTHER PAVEMENT. 3.EXISTING LANDSCAPE TO BE PRUNED ACCORDING TO SPECIES STANDARDS. OVERGROWTH AND WEEDS TO BE REMOVED AND AREA TO BE SODDED OR SEEDED PER NOTES AND SPECIFICATIONS. 4.EXISTING HEDGES TO REMAIN SHOULD BE PRUNED PER NOTES AND SPECIFICATIONS BEDLINE TYP. MULCH INTERIOR This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCLANDSCAPE NOTES DETAILSL07.1 GENERAL NOTES 1.Plants shall be healthy, vigorous material, free of pests and diseases and are subMect to approval/reMection of the Landscape Architect prior to, during and after installation. ReMected plant material shall be removed from site. 2.Contractor shall identify all materials at growing location prior to purchase and submit digital photographs, and source list to the Landscape Architect for approval at a minimum of si[ 6 calendar weeNs prior to installation. Plants not approved shall be re-sourced and resubmitted. 3.Planting beds and individual tree plantings shall be mulched continuously as specified. Planting and bed preparation are to be conducted under favorable weather conditions. Under no circumstance shall soil be worNed, driven over, or walNed upon while in a wet condition. 4.Prior to construction the contractor shall be responsible for locating underground utilities and e[ecute worN in a manner that avoids damage to utilities during the course of worN. Contractor shall be responsible or remedy of any damage to utilities, structures, site appurtenances that occur as a result of landscape related worN. When utility conflicts arise, please contact Landscape Architect. The Contractor is responsible for verifying depths and avoiding conflicts when trenching over or across areas where utilities e[ist. 5.Contractor is responsible for verifying Tuantities shown on documents. In the event of discrepancy, the Contractor shall notify the Landscape Architect prior to bid. Field adMustments shall be approved by Landscape Architect prior to installation. 4uantities indicated on drawings are for reference it is the Contractor s responsibility to ensure full coverage of plants at the indicated spacing. Any plant substitutions proposed reTuire written approval by the Landscape Architect. 6.Contractor is responsible for warranty of all plant material, including seeding and sod, for a period of one 1 calendar year from date of substantial completion. Warranty includes maintenance of all plantings including, but not limited to watering, mowing, edging, spraying, mulching, fertilizing, adMusting staNes, weeding, seeding, and sodding of plantings and turf areas. Watering schedule is at the discretion of the Contractor, so long as plants are maintained in a wilt-free condition and maintain survival. Maintenance commences immediately upon arrival of plant material to the site. All plant material shall be watered immediately after planting. Warranty replacement planting shall meet or e[ceed the original specification identified on drawings. Replacement planting shall e[tend the same warranty as originally installed materials. Plantings and grass areas shall be flourishing and fully thriving at end of warranty period. 6.1.Plants identified for warranty replacement by Owner or Landscape Architect shall be replaced immediately by the Contractor unless otherwise agreed upon. Plantings trees, shrubs, groundcover subMect to warranty replacement shall e[hibit characteristics of 30 dead-per individual plant, non-contributing or disease compromised. Grass areas suitable for acceptance shall demonstrate 5 sustained/consistent and continuous, densely established coverage. Contractor shall perform a site review at end of warranty period and provide the Owner with written documentation of the site, including plant health, warranty replacement items, and conditions that may be influencing plant health. 7.Contractor shall remove all staNing and guying material from plants and site at end of warranty period. .Contractor shall comply with all local, state and federal reTuirements, codes and regulations related to the worN undertaNen. PERFORMANCE SPECIFICATION A.PLANTS A.General 1.Meet or e[ceed measurements specified in the plant schedule. 2.Nursery grown, live, well-branched, and healthy plants free of dead branches and parts. 3.Free of disease, insect, inMury and damage. 4.UnbroNen, intact, dense and solid rootballs and containers, without cracNs, flat sides or previously repaired damage. 5.Free of girdling roots or rootbound/circling container conditions. 6.Plants of consistent in growth habit and healthy character. 7.Free of compromising growth conditions such as weaN crotch connections, crossed branches, snags and scars. .Graded, standards, caliper, sizes and stocN consistent with ANSI Z60.1, American Standard for Nursery Stock most current edition. 9.Species identified consistent with Hortus Third: Concise Dictionary of Plants Cultivated in the United States and Canada, most current edition and Manual of Woody Plants: Their Identification, Ornamental Characteristics, Culture, Propagation and Uses, most current edition. 10.All disturbed areas shall be stabilized per the Erosion and Sediment Control Plans, unless otherwise identified on landscape plans. B.Trees: 1.Deciduous Single TrunN a.Full, straight and upright with consistent symmetrical natural branching pattern throughout. b.Type I specification consistent to ANSI standards. 2.Deciduous Multi-TrunN a.Full and upright with straight consistent symmetrical natural branching pattern throughout. b.Canes evenly spaced and of similar growth habit. c.Free of sucNers and e[traneous branching. 3.Evergreen Single-TrunN a.Full and upright with continuous symmetrical dense natural habit. b.Free of sucNers and e[traneous branching. c.Do not shear or otherwise prune to shape plantings. C.Evergreen and Deciduous Shrubs 1.Full, dense and naturally symmetrical. 2.Free of sucNers and e[traneous branching. 3.Do not shear or otherwise prune or shape plantings. D.Evergreen and Deciduous Groundcover 1.Full and dense in pots or flats E.Perennials and Seasonal Color 1.Full and dense in pots or flats F.Turf Grass 1.Subgrade a.Soil Mi[-10 Compost, 90 topsoil by volume. b.Preparation: Loosen subgrade to a minimum depth of four 4 inches. Remove all non-natural materials including litter, stones, sticNs and all items greater than ô inch in any dimension. c.Preparation: Spread soil mi[ at a depth of four 4 inches continuously to meet grade elevations shown on drawings. Allow for thicNness of sod when applicable. 2.Grass Sod a.Sod as specified per plans or as approved by the Landscape Architect. b.Install not longer than twenty-four 24 hours from harvest. c.Grass bed not less than two 2 inches in continuous thicNness. d.100 continuous live sod coverage after first growing season and at end of warranty period. e.Of uniform non-varying density and continuous te[ture Tuality capable of growth and development immediately upon installation. Weed and no[ious plant free. f.Stagger installation rows and place aligned parallel to contours. g.Fill Moints solidly with planting bed preparation soil. h.Provide anchor pins at twenty-four 24 inches on center for slopes greater than 4:1. i.All permanent sod shall be listed on the current Virginia turf grass variety recommendations and be blue bag certified. 3.Grass Seed a.Mi[ as specified per plans or as approved by the Landscape Architect. b.Provide first and new of year seed crops in mi[ free of weed seeds and deleterious matter. c.Provide seed mi[ not greater than 15 annual or perennial rye. d.Replacement or overseeding mi[es consistent with original application/installation. e.Provide erosion blanNets or other slope retention methods as noted on drawings. f.All permanent seed shall be listed on the current Virginia turf grass variety recommendations and be blue bag certified. g.Seed rate eTuals one 1 pound per 1000 SF, or as per manufacturer s specification, or Murisdictions reTuirement. II.Materials and Appurtenances A.Testing 1.Materials testing information/certificates/dated labels shall be current to the proMect and performed/certified not greater than 120 calendar previous days from current date of submittal for review. B.Top Soil 1.Neutral Ph balance 5.5 -7.5. Friable and containing 2.0-5.0 organic matter by dry weight. Continuously free of non-soil items such as stones, debris, sticNs, trash, and deleterious matter greater than ô inch in any direction. Clay content shall not e[ceed 25.Gravel content shall not e[ceed 10. Silt shall not e[ceed 25. C.Use of Existing Topsoil 1.E[isting topsoil on-site may be repurposed with prior Owner or proMect officer approval. Contractor shall provide soil testing and additive program that demonstrates consistent performance with characteristics and composition as identified in section II.B.1. D.Shredded Hardwood Mulch 1.100 organic shredded first year hardwood free of deleterious matter, rocN, gravel and weed seed. Neutral pH balance 5.5-7.5. 2.Mulch top of root ball and saucer within 4 hours to a minimum of 2 inches and to a depth not to e[ceed 3 inches, or as specified in planting details, whichever is greater. 3.Mulch to bed lines where shown. Hedges are to be mulched as continuous beds, not individually, of the width shown on the plans. Trees shall be mulched within a minimum three 3 foot radius of each trunN or as identified on the plans. No mulch is to be placed in the plant crowns or against tree trunNs within 6 inches. E.Compost pH 1.Balanced 5.0-.5 pH mature, stable and weed free produced by natural aerobic decomposition. Free of visible contaminants and to[ic substances. Not greater than 5 sand, silt, clay or rocN by dry weight. Consistent with US-EPA CFR Title 40 Part 503 Standards for Class A biosolids. 2.Compost Testing 2.1.Prior to delivery on-site, the following items are reTuired for approval by Owner: FeedstocN percentage in final compost product statement that the products meets federal, state and local health safety reTuirements. 2.2.Provide copy of lab analysis less than 120 calendar days old verifying that the product meets described physical reTuirements chemical contaminants Ph physical contaminants biological contaminants including a statement that fecal coliform and salmonella testing and results comply with reTuirements of the US Composting Council Seal of Testing approval programs. G. Planting Soil Mix 1. 75 topsoil and 25 Compost. H.Fertilizer 1.Turf - Granular 10 Nitrogen, 20 Phosphorous, 10 Potassium Rate as recommended per manufacturer instructions. Product and Material Safety Data as approved by Owner. 2.Trees and Shrubs - Slow-release/tablet, 10 Nitrogen, 6 Phosphorous, 4 Potassium. Product and Material Safety Data as approved by Owner. I.Hardwood Stakes 1.2 [ 2 [ 4 inch sTuare of sound hardwood. 2.All tree staNing shall not conflict with pedestrian travel. J.Tree Ties 1. Villa Non-Abrasive Rubber Tree Ties or as specified per the detail, or approved eTual. III.Execution A.Site Conditions 1.Inspect site and notify Owner in writing of acceptance with indication that proMect conditions are acceptable are suitable to proceed with worN. Notify Owner of any e[isting damage and/or other conflicting conditions. 2.Do not proceed with worN until unsatisfactory conditions have been satisfactorily remedied. Notify Owner of acceptance prior to commencement of worN. 3.Notify Owner in writing of any conditions that may preclude successful completion of worN including items such as coordination with other trades, incomplete worN, drainage, soil temperature and/or composition, access to storage/worN areas, damage to conditions, etc. 4.Notify Owner in writing immediately of any items that may influence worN schedule, timing of tasNs, materials delivery and/or installation and warranty responsibilities. 5.Coordinate and cooperate with other trades worNing in and adMacent to worN areas. E[amine drawings of other trades which show development of the entire proMect and become familiar with the scope of reTuired worN by others. B.Planting Seasons Recommended seasons are a general guide based on historical climatic data and typical performance of plantings, and which vary dependent on proMect-specific environmental conditions. Due to construction schedules, recommended planting seasons may or may not coincide with reTuest s for certificate of occupancy for proMects. Coordination of planting installation and seasons shall be reviewed with Owner on an individual proMect basis. 1.Recommended planting seasons are March 15 - June 15 Spring and September 15 - November 15 Fall . 2.Do not install plantings or turf grass between June 15 and September 15, without approval by Owner. 2.1.Do not install/plant seed or sod turf grass areas when ambient air temperature is below forty 40 degrees Fahrenheit, or forecast for a twelve 12 hour period after completion of worN. C.Positioning & Location of Plantings 1.Position plants to show the most-prominent and well-formed face to most-public view. 2.Field locate plants and location/spacing/dimension of planting beds on proMect site prior to beginning installation. D.Implementation 1.Pursue worN continuously without delay or interruption until completion unless notified otherwise by Owner. 2.Provide proMect submittals ahead of commencement of worN. Landscape Architect reTuires a minimum of ten 10 worNing days from date of receipt for review of submittals and response to Owner and Contractor, or per proMect specifications. 3.Continuously update implementation schedule and notify Owner of progress. Delays related to material availability are not cause for non-completion of scheduled delivery of worN. 4.Report delays due to weather or site conditions immediately upon finding. Provide recommendation for remedy of schedule delays. 5.Report delays due to e[traordinary natural or other conditions beyond control of Contractor. 6.E[cavate planting beds and pocNets to a depth reTuired for planting consistent with planting details. 6.1.Remove the burlap, twine, and wire basNets from the top 1/2 of all B B root balls. 6.2.Remove entirety of plastic pots from all plant material. 6.3.Remove any rocN or other underground obstructions to depth necessary to permit planting consistent with planting details. 7.It shall be the responsibility to perform all worN in a manner that protects completed worN by others, such as curbs, utilities, storm drainage, fences, driveway aprons, drives, vegetation, etc. The Contractor shall be responsible for the cost of satisfactory repair of all damage in Nind resulting from their failure to comply. .Contractor shall perform a site review at end of warranty period and provide the Owner with written documentation of the site, including plant health, warranty replacement items, and conditions that may be influencing plant health. E.Clean Up 1.The worN area is to be Nept reasonably neat and clean and all debris hauled away and disposed of legally, off-site, in a timely manner. 2.Remove trash, debris and worN materials from site prior to reTuest for substantial completion. Thoroughly clean surfaces impacted by worN including building, parNing areas, roadways, sidewalNs, signs, lights, site furnishings, etc. 3.Repair any damage to e[isting conditions that occurred during e[ecution of worN. 4.All clean-up and demobilization procedures shall be performed to satisfaction of the Owner and Landscape Architect. 2X WIDTH OF ROOT BALL NOTE: SHRUBS INSTALLED IN CONTINUOUS SUCCESSION OR LARGE BED SHALL BE PLACED IN ONE CONTINUOUS DEPTH BED SCARIFY SIDES OF PLANTING PIT SET SHRUB FLUSH TO GRADE OR UP TO 1/ DEPTH OF ROOT BALL 2-3 LAYER OF MULCH PLANTING SOIL MIX UNDISTURBED SOIL PEDESTAL. SET SHRUB PLUMB IN PLANTING PIT EXISTING SUBGRADE B NOT TO SCALE SHRUB PLANTING 3x WIDEST DIMENSION OF ROOT BALL6 -0PLAN VIEW NON-ABRAISIVE RUBBER TREE TIES TREE STAKES PREVAILING WIND CENTRAL LEADER REMOVE NURSERY STAKE NON-ABRAISIVE RUBBER TIES. THREE 3 TWO INCH TREE STAKES. INSTALL 6 AWAY FROM EDGE OF THE ROOT BALL. STAKE LOCATION SHALL NOT INTERFERE WITH PERMANENT BRANCHES PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6 LIFTS TO BRACE TREE. DO NOT OVER-COMPACT WHEN THE PLANTING HOLE HAS BEEN BACKFILLED PLANTING SOIL MIX 2-3 LAYER OF MULCH. MULCH ON TOP OF ROOT BALL SHALL NOT EXCEED 1 FINISHED GRADE. EXISTING SUBGRADE. SCARIFY SIDES OF PLANTING PIT TOP OF ROOT BALL SHALL BE FLUSH OR UP TO 1/ DEPTH OF ROOT BALL WITH FINISHED GRADE. CUT REMOVE BURLAP ROPES FROM TOP 1/2 OF ROOTBALL. -NON-BIODEGRADABLE MATERIAL (WIRE BASKET) SHALL BE TOTALLY REMOVED UNDISTURBED SOIL PEDESTAL. SET TREE PLUMB IN PLANTING PIT A NOT TO SCALE DECIDUOUS TREE PLANTING WWLWWLBBB WWW W W W W W W W W W WWWWWT WWWWWWW W W W W W STOP STOPSTOPEETT T T T T T T T E E E E E E T T TEE TTTTTT TTTTTT WGASUGEUGEU G E UGE UGE UGE UGE UGE UGE UGE UGE UGE UGEUGEUGEUGEUGEWSWWWWLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLOD1 6 1 2 1 6 2 2 1 2 1 6 2 4 113.4 1 241.7 112 37.5 1 63.74 2 646. 112 COORDINATE CONTROLLER LOCATION WITH GENERAL CONTRACTOR. PLAN IS DIAGRAMMATIC. CONTRACTOR SHALL INSTALL ALL IRRIGATION E4UIPMENT IN LANDSCAPE OR TURF AREAS WITHIN PROJECT LIMITS. 1 4 2 4 1 4 1 4 534.7 112 740.2 112 IRRIGATION SYSTEM NOTES 1.CONTRACTOR SHALL REFER TO THE IRRIGATION DETAILS, IRRIGATION SCHEDULE, SPECIFICATIONS AND ALL CONTRACT DOCUMENTS FOR FURTHER INSTRUCTIONS. 2.IRRIGATION 4UANTITIES ARE PROVIDED FOR CONVENIENCE. IN THE EVENT OF 4UANTITY DISCREPANCIES THE DRAWING SHALL TAKE PRECEDENCE. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT PRIOR TO BIDDING. 3.ANY SUBSTITUTIONS FOR SPECIFIED IRRIGATION E4UIPMENT MUST BE APPROVED BY THE LANDSCAPE ARCHITECT OR OWNER S REPRESENTATIVE IN WRITING PRIOR TO CONSTRUCTION. 4.CONTRACTOR SHALL FIELD ADJUST LOCATION OF IRRIGATION E4UIPMENT AS NECESSARY TO AVOID DAMAGE TO EXISTING UNDERGROUND UTILITIES AND/OR INTERFERE WITH EXISTING ABOVE GROUND ELEMENTS. ALL FIELD ADJUSTMENTS SHALL BE COMPLETED AT THE CONTRACTOR S EXPENSE AND SHALL BE COORDINATED WITH THE OWNER S REPRESENTATIVE AND THE LANDSCAPE ARCHITECT. 5.CONTRACTOR SHALL FAMILIARI=E HIM/HERSELF WITH THE LIMITS OF WORK AND EXISTING CONDITIONS AND VERIFY ALL INFORMATION. IF DISCREPANCIES EXIST, CONTRACTOR SHALL NOTIFY OWNER S REPRESENTATIVE IN WRITING WITHIN SEVEN CALENDAR DAYS OF NOTICE TO PROCEED. 6.IRRIGATION PLAN IS DIAGRAMMATIC. E4UIPMENT SHOWN ON IMPERVIOUS SURFACES IS FOR GRAPHIC CLARITY UNLESS OTHERWISE NOTED. CONTRACTOR SHALL INSTALL ALL E4UIPMENT WITHIN LANDSCAPE AREAS IN PROPERTY LIMITS. SYMBOL MANUFACTURER/MODEL/DESCRIPTION 4TY PSI Rain Bird 106-PRS 15 Strip Series Turf Spray 6.0in. Pop-Up SprinNler with Co-Molded Wiper Seal. Side and Bottom Inlet. 1/2in. NPT Female Threaded Inlet. Pressure Regulating. 21 30 Rain Bird 106-PRS  Series MPR Turf Spray 6.0in. Pop-Up SprinNler with Co-Molded Wiper Seal. Side and Bottom Inlet. 1/2in. NPT Female Threaded Inlet. Pressure Regulating. 73 30 Rain Bird 106-PRS 10 Series MPR Turf Spray 6.0in. Pop-Up SprinNler with Co-Molded Wiper Seal. Side and Bottom Inlet. 1/2in. NPT Female Threaded Inlet. Pressure Regulating. 16 30 Rain Bird 106-PRS 12 Series MPR Turf Spray 6.0in. Pop-Up SprinNler with Co-Molded Wiper Seal. Side and Bottom Inlet. 1/2in. NPT Female Threaded Inlet. Pressure Regulating. 22 30 Rain Bird 106-PRS 15 Series MPR Turf Spray 6.0in. Pop-Up SprinNler with Co-Molded Wiper Seal. Side and Bottom Inlet. 1/2in. NPT Female Threaded Inlet. Pressure Regulating. 39 30 Rain Bird 106-PRS ADJ Turf Spray 6.0in. Pop-Up SprinNler with Co-Molded Wiper Seal. Side and Bottom Inlet. 1/2in. NPT Female Threaded Inlet. Pressure Regulating. 41 30 Rain Bird 112-PRS 15 Strip Series Shrub Spray 12 Pop-Up SprinNler with Co-Molded Wiper Seal. Side and Bottom Inlet. 1/2 NPT Female Threaded Inlet. With Pressure Regulating Device. 15 30 Rain Bird 112-PRS 10 Series MPR Shrub Spray 12 Pop-Up SprinNler with Co-Molded Wiper Seal. Side and Bottom Inlet. 1/2 NPT Female Threaded Inlet. With Pressure Regulating Device. 30 Rain Bird 106-1400 Flood Flood Bubbler 6.0in. popup, install w/ PA-0 adapter. 15 30 SYMBOL MANUFACTURER/MODEL/DESCRIPTION 4TY Rain Bird PEB 1in., 1-1/2in., 2in. Plastic Industrial Remote Control Valve. Low Flow Operating Capability, Globe Configuration. 7 Febco 25Y 1 Reduced Pressure BacNflow Preventer 1 Rain Bird ESP-LXD 50 Station, 2-Wire Decoder based Controller. 1 ESP-LXD 50-Station, Indoor/Outdoor, Plastic Wall-Mount Enclosure. System ReTuirements: Rain Bird FD-XXX-TURF Field Decoders, Paige Electric Cable P7072D Rain Bird WC20 Dry Splices ONLY. Ground System w/ X LSP-1TURF Line Surge Protectors in Rain Bird Round Valve Bo[es. Install Per Manufacturers Recommendations. 1 Hunter MINI-CLIK Rain Sensor, mount as noted 1 Water Meter 11 Irrigation Lateral Line: PVC Class 200 SDR 21 3,32 lf Irrigation Mainline: PVC Schedule 40 46.2 lf Pipe Sleeve: PVC Schedule 40 1.3 lf IRRIGATION SCHEDULE /- AS NEEDED /- NUMBER MODEL SI=E TYPE GPM PSI PSI # POC 1 Rain Bird PEB 1Shrub Spray 13.35 32.45.9 2 Rain Bird PEB 1-1/2Turf Spray 41.636.3 60.4 3 Rain Bird PEB 1Bubbler 7.5 32.6 45.2 4 Rain Bird PEB 2Turf Spray 63.66 36.5 64.4 5 Rain Bird PEB 1-1/2Turf Spray 34.74 35.1 55.2 6 Rain Bird PEB 1-1/2Turf Spray 46.3 37.9 67.1 7 Rain Bird PEB 1-1/2Turf Spray 40.19 36.6 60.5 VALVE SCHEDULE Generated:2026-02-03 0:19 P.O.C. NUMBER: 01 Water Source Information: FLOW AVAILABLE Water Meter Size:1 Flow Available 37.5 GPM PRESSURE AVAILABLE Static Pressure at POC:79 PSI Elevation Change:5.00 ft Service Line Size:4 Length of Service Line:20 ft Pressure Available:77 PSI DESIGN ANALYSIS Ma[imum Station Flow:63.66 GPM Flow Available at POC:37.5 GPM Residual Flow Available:-26.16 GPM Critical Station:6 Design Pressure:30 PSI Friction Loss:3.92 PSI Fittings Loss:0.39 PSI Elevation Loss:0 PSI Loss through Valve:3.57 PSI Pressure ReT. at Critical Station:37.9 PSI Loss for Fittings:0.41 PSI Loss for Main Line:4.13 PSI Loss for POC to Valve Elevation:0 PSI Loss for BacNflow:11.4 PSI Loss for Water Meter:13.3 PSI Critical Station Pressure at POC:67.1 PSI Pressure Available:77 PSI Residual Pressure Available:9.9 PSI CRITICAL ANALYSIS This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCNORTH IRRIGATION PLANL0AAPAAPJSH AS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM111125000VIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLC4 4 21 2 1-1/2 6 6 3 2-1/2 1/4 X 2 METAL STRAP NOTES: 1.4 MINIMUM PIPE SI=E FOR THRUST BLOCKS 2.MIN. THRUST BLOCK SI=E SHALL BE 2 CU. FT. 2 X 2 X 2 VALVE ANCHOR 6 TREE BUBBLER NOT TO SCALE 3 REMOTE CONTROL VALVE NOT TO SCALE FINISH GRADE SPRAY HEAD SWING JOINT: HUNTER PRO-FLEX TUBING, HSBE-050 ELBOWS 2 , MARLEX STREET ELBOW 1 OR APPROVED E4UAL LATERAL TEE OR ELL LATERAL PIPE 1 BACKFLOW PREVENTER TYP. NOT TO SCALE 5 SPRAY HEAD NOT TO SCALE THRUST BLOCK NOT TO SCALE 11 SLEEVE INSTALLATION TYP. NOT TO SCALE 7 SLEEVE SI=E SCHEDULE TYP. NOT TO SCALE SLEEVE SI=EPIPE SI=E GRAVELPEAPIPE CMP OR PLASTIC COMPACTED SUBGRADE SCH. 40 TEE MAIN LINE 3 STENCIL ON TOP OF LID W/ YELLOW PAINT CONTRACTOR TO PAINT =ONE IDENTIFICATION WITH ELECTRIC REMOTE CONTROL VALVE 10 DIA. [ 12 CORRUGATED SEE PLAN FOR TYPE SI=E SCH. 40 NIPPLE T.O.E. SCH. 40 UNION SCH. 40 ELL 10 VALVE BOX SCH. 40 PVC WIRE FINISHED GRADE 18" min.SCH. 40 PVC 90ƒ THREADED ELBOW SCH. 40 PVC TEE OR 90ƒ ELBOW. EDGE OF ROOT BALL. EXISTING OR MODIFIED SOIL. LATERAL LINE BUBBLER BUBBLER HEAD CHECK VALVE SCH 0 NIPPLE FINISH GRADE SCH 40 THREADED COUPLER FLEXIBLE SWING JOINT THREADED TEE OR ELBOW OFF LATERAL LINE LATERAL PIPE PLAN VIEW SECTION VIEW BELOW GRADE. USE PVC SCH. 40 FINISHED GRADE. LONG SWEEP ELL. 1/2 DIAMETER RIGID STEEL CONDUIT FOR 110 VAC ELECTRICAL SOURCE. INSTALL AS PER LOCAL ELECTRICAL CODES. CONTROLLER AS SPECIFIED. SECURELY BOLT CONTROLLER TO WALL. INSTALL BACKUP BATTERIES AS RE4UIRED. GROUND AS PER MFG. SPECIFICATIONS. NOTE: SET CONTROLLER 60 ABOVE FINISHED GRADE UNLESS OTHERWISE NOTED. 1 1/2 DIAMETER RIGID STEEL CONDUIT FOR RCV WIRES. 2 CONTROLLER MOUNT NOT TO SCALE IRRIGATION MAIN OR SUBMAIN TYP. PVC IRRIGATION LATERAL 24 MIN. WIDTH MAY VARY EXISTING SOIL 1 MIN. BACKFILL WITH NATIVE SOIL, WATER JET COMPACT TO 90 OPTIMUM DENSITY. ALLOW 4 HOURS TO SETTLE, AND BACKFILL AND COMPACT WITH NATIVE SOIL. NATIVE SOIL BACKFILL COMPACT TO 95 COMPACTION 4 MIN. 4 MIN. 4 MIN. BEDDING 4 MIN. MAX.3 TOPSOIL 16 GAUGE PULL WIRE GRAVEL MIX OR PLANTING 3 CONC. CURB GUTTER 2 PAVEMENT BACKFILL NOTE: 1.ALL SLEEVES TO EXTEND 2 BEYOND BACK OF CURB ON EACH END. 2.NO 90ƒ OR 45ƒ COUPLINGS TO BE USED ON SLEEVES. 3.SLEEVES MUST BE STRAIGHT TO ALLOW PIPE TO BE INSERTED BY IRRIGATION CONTRACTOR. 4.SLEEVES NOT INSTALLED AT PROPER DEPTH WILL BE REINSTALLED TO CONFORM TO DETAIL 5.CONTRACTOR TO VERIFY SLEEVE INTEGRITY PRIOR TO FINAL PAVING. 6.CONTRACTOR TO ANTICIPATE SLEEVE LOCATIONS BOTH MAINLINE AND WIRE CHASE FOR COMPLETION OF LOOP SYSTEM AND ANY NECESSARY ACCESS FOR FUTURE IRRIGATION LAYOUT AND ASSOCIATED VALVES. CONTRACTOR TO COORDINATE WITH GENERAL CONTRACTOR FOR SUGGESTIONS / PHASING PLAN REFERENCE, ETC. 10 TRENCHING DETAIL NOT TO SCALE SWEEP EL TYP. FINISHED GRADE PULL WIRE SLEEVE PROVIDE SEPARATE 1 CHASE FOR CONTROL WIRING TO ACCOMPANY ALL MAINLINE SLEEVES FOR ACCESS TO ALL VALVES PROPOSED AND FUTURE TEMPORARY RISER AND CAP SOLVENT WELD CAP TO RISER 4 RAIN SENSOR NOT TO SCALE 1.EXTERIOR WALL SEE NOTE 2.MODEL: IRRITROL RS 1000 NOTE: MOUNT SENSOR ON SURFACE WHERE IT WILL BE EXPOSED TO UNOBSTRUCTED RAINFALL, BUT NOT IN PATH OF SPRINKLER SPRAY. COORDINATE MOUNTING WITH OWNER AND ARCHITECT. IF USING 1402 0.5 GPM HEAD, 1 BUBBLER RE4UIRED. IF USING A HEAD LESS THAN 0.5 GPM, USE MULTIPLE HEADS 24 MIN. BELOWFINISHED GRADE36 MIN. BELOWFINISHED GRADE9 WATER SERVICE CONNECTION 3/4"=1'0" BacNflow prevention device. Install the device per the local water purveyor s standards and specifications.4Galvanized union. Brass ball valve. Threaded galvanized nipple. Galvanized ninety degree 90ƒ elbow. Wrap 20 mil tape twice around all galvanized pipe under finished grade and through the concrete.12 min.or per localcodes.Galvanized nipple. 4 thicN concrete pad, 1 above finished grade. See bacNflow cage detail. Concrete thrust blocNs reTuired on bacNflow devices 2.5 and larger. Galvanized coupling. Galvanized nipple. Note: 1- All assembly parts threaded nipples, fittings, etc. shall be galvanized or brass per local codes and reTuirements. 2- Galvanized nipple shall e[tend 12 past the edge of the concrete footing. 3- Sch. 0 PVC male adapter shall be used in connection from galvanize to the mainline. 4- BacNflow prevention device shall be located as close as possible to the landscape meter. 5- BacNflow prevention device shall be located in planting area unless approved by Owner s Representative. 6- See detail for bacNflow cage installation. 7- All bacNflow prevention devices shall have freeze blanNet included upon installation. - All galvanized connections shall to be made using pipe thread sealant. All Sch. 0 PVC to galvanized connections to be made using teflon tape. Sch. 0 PVC male adapter. Flow IRRIGATION DETAILSL0.1AAP AAPJSH AS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM111125000VIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCLANDSCAPE IRRIGATION SYSTEM PERFORMANCE SPECIFICATIONS PART 1 - GENERAL 1.0 GENERAL SCOPE A.Inspection of Site: The Contractor shall acquaint himself with all site conditions, including underground utilities before construction is to begin. Contractor shall coordinate placement of underground materials with contractors previously working underground in the vicinity or those scheduled to do underground work in the vicinity. Contractor is responsible for minor adjustments in the layout of the work to accommodate existing facilities. B.Protection of Existing Plants and Site Conditions: The Contractor shall take necessary precautions to protect site conditions to remain. Should damages be incurred, this Contractor shall repair the damage to its original condition at his own expense. Any disruption, destruction, or disturbance of any existing plant, tree, shrub, or turf, or any structure shall be completely restored to the satisfaction of the Owner and his representatives, solely at the Contractor's expense. C.Protection of Work and Property: The Contractor shall be liable for and shall take the following actions as required with regard to damage to any of the Owner's property. 1.Any existing building, equipment, piping, pipe coverings, electrical systems, sewers, sidewalks, roads, grounds, landscaping or structure of any kind (including without limitation, damage from leaks in the piping system being installed or having been installed by Contractor) damaged by the Contractor, or by his agents, employees, or subcontractors, during the course of his work, whether through negligence or otherwise, shall be replaced or repaired by Contractor at his own expense in a manner satisfactory to Owner, which repair or replacement shall be a condition precedent to Owner's obligation to make final payment under the Contract. 2.Contractor shall also be responsible for damage to any work covered by these specifications before final acceptance of the work. He shall securely cover all openings into the systems and cover all apparatus, equipment and appliances, both before and after being set in place to prevent obstructions on the pipes and the breakage, misuse or disfigurement of the apparatus, equipment or appliance. 3.All trenching or other work under the leaf canopy of any and all trees shall be done by hand or by other methods so that no branches are damaged in any way. Buildings, walks, walls, and other property shall be protected from damage. Open ditches left exposed shall be flagged and barricaded by the Contractor by approved means. The Contractor shall restore disturbed areas to their original condition. 4.The Contractor shall be responsible for requesting the proper utility company to stake the exact location of any underground lines including but not limited to electric, gas, telephone service, water, and cable. 5.The Contractor shall take whatever precautions are necessary to protect these underground lines from damage. In the event damage does occur, all damage shall be completely repaired to its original condition, at no additional cost to the Owner. 6.The Contractor shall request the Owner, in writing, to locate any private utilities (i.e., electrical service to outside lighting) before proceeding with any excavation. If, after such requests and necessary staking, private utilities which were not staked are encountered and damaged by the Contractor, they shall be repaired by the Owner at no cost to the Contractor. If the Contractor damages staked or located utilities, they shall be repaired at the Contractor's expense. D.The Contractor shall keep on his work, during its progress, a competent superintendent and any necessary assistants, all satisfactory to the Owner, or Owner's representative. E.The superintendent shall represent the Contractor in his absence and all directions given to him shall be as binding as if given to the Contractor. F.Guarantee: All work shall be guaranteed for one year from date of final acceptance against all defects in material, equipment and workmanship to the satisfaction of the Owner. Repairs, if required, shall be done promptly at no cost to the Owner. 1.The guarantee shall also cover repair of damage to any part of the premises resulting from leaks or workmanship, to the satisfaction of the Owner. The Contractor shall not be responsible for work damaged by others. Repairs, if required, shall be done promptly. The guarantee shall state the name of the Owner, provide full guarantee terms, effective and termination date, name and license number of Contractor providing guarantee, address, and telephone number. It shall be signed by the chief executive of the Contractor of his liability under the guarantee. Such warranties shall only supplement the guarantee. 2.If, within ten (10) days after mailing of written notice by the Owner to the Contractor requesting repairs or replacement resulting from a breach of warranty, the Contractor shall neglect to make or undertake with due diligence to make the same, the Owner may make such repairs at the Contractor's expense; provided, however, that in the case of emergency where, in the judgment of the Owner, delay would cause serious loss or damage, repairs or replacement may be made without notice being sent to the Contractor, and Contractor shall pay the cost thereof. 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1 Specification Sections, apply to work of this Section. 1.2 WORK INCLUDED: A. Work of this section provides a performance specification for the design and installation of a complete irrigation system for the project. 1.3 QUALITY ASSURANCES: A. Applicable requirements of accepted standards and codes shall apply to the work of this section: 1. ASTM - American Society for Testing Materials. D2241: Polyvinyl Chloride (PVC) Plastic Pipe (SDR-PR). D2287: Flexible Polyvinyl Chloride (PVC). D2464: Polyvinyl Chloride (PVC) Plastic Pipe Fittings, Threaded, Schedule 80. D2466: Polyvinyl Chloride (PVC) Plastic Pipe Fittings, Socket Type, Schedule 40. D2564: Solvent Cements for Polyvinyl Chloride (PVC) Plastic Pipe and Fittings. D2855: Making Solvent - Cemented Joints for Polyvinyl Chloride (PVC) Pipe and Fittings. 2. National Plumbing Code (NPC) 3. National Electric Code (NEC) 4. National Sanitary Foundation (NSF) 1.4 DEFINITION A.Irrigation Design: Design of irrigation system to meet any applicable Municipality standard specifications. Irrigation design to be completed by a Irrigation Designer certified by the Irrigation Association or as approved by Raising Cane's. Contractor shall be responsible for obtaining any approvals/ permits required by the local governing authority. B. Irrigation Mains: That portion of piping from water source to remote control valves. This portion of piping is subject to surges, being a closed portion of irrigation system. Hydrant lines (QCV) are considered part of main line piping system. C. Lateral Piping: that portion of piping from remote control valve to sprinkler heads and tubing. 1.5 SYSTEM DESCRIPTION: A. Design and install to provide complete head to head coverage not to exceed 5 feet per second through pipe, designed for matched precipitation for lawn and planting as follows: 1.All seeded lawn areas 2. All new sodded areas 3.All new shrub beds and new tree planting areas, incl. parking lot islands. (Drip irrigation shall be utilized for all planting beds) Design, furnish and install an operating system, complete with electrical connection, backflow preventers & enclosures, automatic controllers, main and lateral lines, sprinkler heads, Drip lines, remote control valves, quick coupler valves, wires and any other items required for a complete and operating system. Contractor shall provide a controller schedule with the design. 1.6 SUBMITTALS: A. Irrigation Maintenance and Operating Instruction Manual: Manufacturer's literature for approved products in triplicate, neatly bound in a black vinyl three ring binder with cover entitled "Irrigation Maintenance and Operating Instruction Manual" with name and address of project, date of submission, and name and address of Designer and Contractor. Include parts numbers actually used, supplier's name, address, and telephone, and scheduled inspections required. Also include a suggested system operating schedule with precipitation rates for each zone. Manufacturer's literature shall include the following: 1. Sprinkler Heads 2. Drip Irrigation emitters 3. Valves: manual and automatic 4. Controller 5. Valve Boxes 6. Pipe, Tubing, and Fittings 7. Wire 8. Meter 9. Backflow Prevention Device 10. Misc. materials (such as rain and temperature check devices, etc.) or items as described on the irrigation schedule B. Project Record Documents: 1. Submit preliminary design to Owner/Engineer for approval prior to any construction. 2. Maintain in good order at site, one copy of approved design drawings, specifications, addenda and approved change orders, and record changes and other modifications made during construction. 3. Upon completion of work, transpose changes to AutoCAD and submit a hard copy of the as-built drawing with each product data manual. 4. Submit 2 complete product data manuals with as-built to the Owner/Engineer prior to issuance of final acceptance. As built-drawing to include location, by written dimension, of mainline piping, remote control valves and quick coupler valves. Title “Record Drawing" and include date, signature, and license of installer. Product Data Manual shall include: a. Table of Contents b. Written description of the irrigation system c. System drawings: 1 one copy of design drawings 2. one copy of record as-built 3. manuf. data with specific model, type and size 4. winterization and spring start-up procedures 1.7 PROJECT/SITE CONDITIONS A. Water Supply: Owner/ General Contractor will provide water for required testing, flushing and jetting. B. Electrical Supply: Contractor shall be required to make final connection to controller. C. Sleeves and Ducts: Provide sleeves and/or ducts at all road/pavement crossings. Extend sleeves 36" deep under paving and 18" min. beyond paving and cap lines handtight, refer to detail. Do not use as main or lateral lines. D. Existing Utilities and Structures: Review utility structure as-builts and consult with the appropriate utility companies for location prior to commencing installation. Repair damage due to installation immediately. Make necessary adjustments in the layout as may be required to connect to existing stubouts, as may be required to work around existing conditions. E. Storage: Space will be designated at the site. F. Deliver materials in original package, cartons, and containers bearing the name of manufacturer, brand, and model number. Pipe shall be stored on pallets a minimum of 4" off of the ground. G. Protect irrigation system materials before, during and after installation. Exercise care in handling, loading, unloading, covering and storing plastic pipe and fittings until ready to install. H. In the event of damage, immediately make repairs and replacements necessary at no additional cost to Owner. 1.8 SCHEDULING A. Coordinate with Landscape Contractor and his landscape work. B. Prepare a detailed schedule coordinated with the work of other contractors doing work at the site. C. Monitor schedules on a regular basis so potential variances can be determined and resolved. D. Verify all product orders so deliveries are timed to maintain construction schedules. 1.9 WARRANTY A. The Contractor shall fully warrant the landscape irrigation system for a period of one (1) year after the written final acceptance and will receive a written confirmation from the Landscape Architect that the warranty period is in effect. B. During the warranty period, the Contractor will enforce all manufacturer's and supplier's warranties as if made by the Contractor himself. Any malfunctions, deficiencies, breaks, damages, disrepair, or other disorder due to materials, workmanship, or installation by the Contractor and his suppliers shall be immediately and properly corrected to the proper order as directed by the Owner and/or Landscape Architect. C. Any damages caused by system malfunction shall be the responsibility of the Contractor who shall make full and immediate restoration for said damages. 1.10 MAINTENANCE A. Provide maintenance of system including cleaning and adjustment of heads, raising and lowering of heads, cleaning filters, flushing lateral lines and tubing until final acceptance. B. Repair backfill settlement of trenches prior to acceptance. C. Drain and flush system within one-year guarantee period. D. Instruct Owner and Owner's personnel in operation and general maintenance of system. Provide Owner with a maintenance manual of materials installed bound in a three-ring black vinyl binder. E. Repair of damage caused by vandals, other contractors or weather conditions shall be considered extra to the work. F. Maintain the entire irrigation system in proper working order and program the controllers in consultation with Landscape Contractor prior to final acceptance. G. Provide the Owner with a letter summarizing the one-year warranty and timeframe stated in this specification and date of final acceptance. This letter shall serve as the Contractor's written guarantee. PART 2 - PRODUCTS 2.0 EXTRA EQUIPMENT A.One quick coupler key for every 3 quick couplers with one hose swivel and one brass boiler drain each. B. Three (3) keys to controller. C. Five (5) spare sprinkler heads and nozzles, (each type). 2.1 POLYVINYL CHLORIDE PIPE A. Manufactured in accordance with standards noted herein: 1. Marking and Identification: Continuously and permanently marked with manufacturer's name, pipe size, pipe type and material, SDR number, ASTM standard number and NSF (National Sanitation Foundation) seal. 2. Pipe Fittings: Of same material as PVC pipe specified and compatible with PVC pipe furnished. 3. PVC Pipe: Laterals: Class 200, SDR 21; Mainline: Schedule 40 Under paved surfaces and in sleeves to be Schedule 40. 4. Sleeves: Refer to Detail. 2.2 COPPER TUBING AND FITTINGS A. Hand straight lengths of domestic manufacture, Type "M." Do not use foreign extrusion or irrigation tubing. B. Copper Tube Fittings: Cast bronze or wrought copper or sweat-solder type. C. Use only 60-40 "no lead" solder on copper joints. 2.3 VALVE WIRING Type UF, No. 14 gauge with 4/64" insulation, Underwriters Laboratory approved for direct underground burial when used in National Electrical Code, Class II circuit (30-volts AC or less). Color code wire red for lead wire and white for common wire. 2.4 WIRE SPLICES "Dri-Splice" as manufactured by Spears Manufacturing Company, "DBY Connectors" as manufactured by 3-M Company or "One Step" as manufactured by King Technology, Inc. 2.5 SOLVENT, CLEANER, AND PRIMER A. Conform to ASTM D2S64. B. PVC Pipe and Fittings: Weld-on #705 Solvent and #P-70 Primer. 2.6 QUICK COUPLER VALVES Shall be 3/4" bronze bodied valves with a rubber seat and plated cover. Keys shall be bronze constructed with 3/4" FIP X 3/4" MIP threaded 2.7 SWING JOINTS One (1") inch unitized "full circle" type. Use Teflon tape on all threaded joints and draw joints up snugly, do not overtighten. 2.8 SPRAY HEAD A. Spray head shall have built-in pressure regulating heads to regulate pressure to 30 psi. B. Seed/Sod Spray Heads: ABS body with a 3-1/2" spring loaded pop-up nozzle assembly and 1/2" FIP connection in base. C. Shrub Spray Heads: ABS body with a 12" spring loaded pop-up nozzle assembly and 1/2" FIP connection in base. D. Nozzles: Matched precipitation rates (MPR) 2.9 DRIP IRRIGATION Trees and shrubs will have a commercial grade drip irrigation emitter system. 2.10 ELECTRIC VALVES Normally closed, globe-type diaphragm, glass-filled nylon body and cover, and Buna N reinforced diaphragm with 24-volt, 1/4-amp solenoid in a waterproofed housing, rated at 200 psi. 2.11 REINFORCEMENT STAKES One (1") inch galvanized pipe long enough to penetrate at least 36" into undisturbed earth. Use two stainless steel worm gear clamps with stainless steel screws to fasten the state to the quick coupler. 2.12 BACKFLOW PREVENTER Reduced pressure zone (RPZ) backflow preventer or as required by local code, in an above ground insulated hot box. 2.13 VALVE BOXES Non corrosive, heavy duty, superflenan plastic material with covers impregnated with colorfast green pigment. Valve boxes must have a locking cover. Toro, Hunter, Rainbird or equal. 2.14 VALVE BOX BACKFILL Clean, washed gravel graded from 1/2" to 1" diameter. 2.15 BACKFLOW ENCLOSURE A. The backflow prevention device enclosure shall be a commercial manufactured enclosure made specifically for this function, sized to fit the utilized backflow device. It shall be vandal and weather resistant, with stainless steel locking mechanism and mounting hardware. B. A self-activated heating device for the backflow preventer shall be provided and installed by the contractor, including power supply hook-up. C. Irrigation Contractor to coordinate screening of Hot Box with General Contractor and Landscape Contractor 2.16 ELECTRIC CONTROLLER Fabricated so internal parts are accessible through controller door. Electrical components mounted on printed circuit boards with edge connector and plugs for easy removal during maintenance. A. Housing: Interior 18 gauge wall mountable or exterior 16 gauge weatherproofed wall or pedestal mountable locking case as indicated or as selected. B. Electrical Characteristics: Capable of operating 24 VAC electric control valves input power of 117 VAC, 50/60 Hz through resettable circuit breaker to protect controller from power overload and field wiring short circuits. C. Limits of Operating Time per Station: 1 minute to 9 hours, 59 minutes in 1 minute increments. D. Number of Independent Programs: 3 E. Number of Automatic Starts per Day per Program: 4 F. Station Assignability: Every combination of programs G. Program Setability: On either 7 day weekly repeat cycle or on 1 to 6 skip day basis. H. Method of Indicating Program in Operation During Operation: Readout I. Automatic Program Overlap Protection: Capable of allowing only one program to run at one time and ensuring by delaying start times that programmed watering cycles will occur even when cycles are scheduled to start while in conflict with each other. J. Manual Operation: Capable of operation without affecting original programs, of being activated for 1 minute to 9 hours, 59 minutes in 1 minute increments, of activating user programs and of activating systems check feature to run each station for 1 minute, 45 seconds. K. Standby Operation: Preset Back-Up Program capable of maintaining user program during power L. Self-Test Feature: Built-in, capable of checking 1. LED's for lighting and shorts 2. Digital display for lighting and shorts 3. Each key of keyboard for integrity and proper function. 4. Station outputs. 2.17 TEMPERATURE SENSOR Johnson Controls Freeze Sensor. PENN #A19ANC-1. 2.18 RAIN SENSOR Shall be vandal resistant; manufactured by Toro, Hunter, Rainbird or equal, with adjustable interruption point and attached mounting bracket, wired or wireless. PART 3 - EXECUTIONS 3.1 EXAMINATION A. Examine areas and conditions under which system is to be installed. B. Notify Designer in writing of conditions detrimental to proper and timely completion of C. Do not proceed until conditions are acceptable. 3.2 PREPARATION A. Coordinate work which is embedded in concrete or masonry and route under paved B. Provide timely delivery and installation at job site. C. Protect adjacent structures, surfaces, and finishes. Do not move equipment over structures without written approval from Designer. Provide necessary protection such as board roading, drop cloths, etc., as required. 3.3 INSTALLATION A. General: 1. Staking: Before installation is started, place a stake where each sprinkler is to be located in accordance with approved shop drawings. Receive written approval from Irrigation Designer before proceeding. 2. Excavation: Is unclassified and includes earth, loose rock, rock or any combination thereof, in wet or dry state. Contractor shall review geotechnical report and grading plans and include any cost for rock removal in bid. No additional cost for rock excavation will be accepted. 3. Backfill: Use material excavated except where pipe manufacturer's specifications require otherwise. Use select fill dirt or sand if existing soil is rocky or contains large clods. Hand-tamp to prevent after settling. Hand-rake trenches and adjoining areas to match surrounding grades. 4. Pipe Layout: Route around trees and shrubs to avoid damage to root system. Do not dig within root balls of newly planted trees or shrubs. Do not move or damage trees and shrubs. B. Pipe Installation: 1. Sprinkler Main: Install in 4-inch wide (minimum) trench with a minimum of 24 inches of cover. 2. Lateral Piping: Install in 4-inch wide (minimum) trench with a minimum of 18-inches of cover. 3. Trenching: Remove lumber and rubbish greater than 1-1/2 inches in diameter from trenches. Provide a firm, uniform bearing for entire length of pipe to prevent uneven settlement. Pad trenches with dirt or sand if soil is rocky. Do not wedge or block pipe. Snake pipe from side to side of trench bottom to allow for expansion and contraction. Remove foreign matter or dirt from inside of pipe prior to welding and keep clean during and after installation. Do not lay piping in trenches when water is in the trench, when temperature is 36 degrees or below, or when rains are eminent. C. PVC Pipe and Fitting Assembly: 1. Solvent: Use type and procedures recommended by pipe manufacturer to make solvent-welded joints. Thoroughly clean pipe and fitting of dirt, dust, and moisture before applying solvent. 2. PVC to Metal Connection: Work metal connection first. Use a non-hardening pipe dope such as Permatex No. 2 on threaded PVC to metal joints. Use only light wrench pressure. 3. Threaded PVC Connection: Where required, use threaded PVC adapters into which pipe may be welded. D. Copper Tubing and Fitting Assembly: 1. Clean pipe and fitting thoroughly and buff connection with sand paper to remove residue from pipe. 2. Flux pipe and fitting, solder connection using 60-40 soft solid core leak-free solder. E. Sprinklers 1. General: Supply in accordance with equipment list and size shown on approved shop drawings. Revise nozzle degree and trajectory as required by wind condition as affecting coverage. Firmly tamp grade around head. 2. Lawn Spray Head: Install with top side of head flush to one-quarter (1/4") inch above finish grade and 4" minimum from back of curb. Attach to lateral piping with a flexible 1/2" x 12" PVC flexible riser. No polyethylene nipples will be allowed. 3. High-Pop Spray Head: Install with underside of flange flush with finish grade and 4” minimum from back of curb. Attach to lateral piping with a flexible 1/2" x 12" PVC flexible riser. 4. Rotary Head: Install with underside of flange flush with finish grade and 4" minimum from back of curb. Attach to lateral piping with a swing joint as detailed on drawings. 5. Bubblers: Install with flange flush with finish grade. Attach to piping per manufacturer's specifications. F. Quick Coupler Valve Install flush with finish grade. Attach to sprinkler mains with swing joint as detailed on drawings. Install reinforcement stake perpendicular to grade and buried below finish grade two (2") inches minimum. Attach to valve with clamps as detailed. G. Electric Remote Control Valve 1. Supply in accordance with equipment list and size shown on approved shop drawings. 2. Install in a level position deep enough so there will be at least 12 inches of cover over valves and in accordance with manufacturer's specifications. 3. Install a 14" x 19" standard plastic valve box plus ball valve assembly upstream from each valve for servicing. H. Wiring 1. Supply wire from automatic sprinkler controller to valves in accordance to controller manufacturer's specifications. A separate wire is required from controller to each valve. Provide a common neutral wire with white insulation from controller to each valve. 2. Lay wire in trenches provided for piping under the piping taping in bundles every ten (10') feet with plastic electric tape. 3. No conduit is required for wire except under paved areas. 4. Join wires together using water-proof DBY splice kits. 5. Provide 48" expansion coil of valve and ground wire at each remote control valve and splice. Form expansion coil by wrapping firmly and evenly around a piece of one (1") inch PVC pipe. 6. Connect valve wire to both sensors in "series" so either sensor can "open" the “circuit" and shut system down. I. Automatic Irrigation Controller 1. Install according to manufacturer's recommendation at location approved by Owner. All above-ground wiring shall be in conduit conforming to national electric code requirements. Contractor is responsible for power to, and grounding of controller per manufacturers specifications. 2. Program controller system setting operating times and duration as directed by Owner's representative and adjust as required. J. Temperature and Rain Sensors: Install in locations approved by Owner's representative. 3.4 TESTING A. General: Perform required testing under observation of Designer. Give 7 days notice that tests are to be conducted. B. Sprinkler Main: Test for a period of 12 hours under normal water pressure. If pressure drops 3 psi or leaks occur, correct defect and repeat test. C. Lateral Piping: Test for a period of 1 hour under normal water pressure. If leaks occur, correct defect and repeat test. D. Complete testing prior to backfilling. Sufficient backfill may be placed in trenches between fittings to insure stability of line under pressure. In each case, leave fittings and couplings open to visual inspection for full period of test. E. Verify sensor operation to shut system down by filling rain sensor with 1/4" of water. Then place temperature sensor in ice. 3.5 FINAL ADJUSTMENT A.Adjustment and Coverage of System: Coordinate pressure testing with adjustments and coverage test of system so both may occur at the same time. The Contractor shall balance and adjust the various components of the system so that the overall operation of the system is most efficient. This includes a synchronization of the controllers, adjustments to pressure regulators, pressure relief valves, part circle sprinkler heads, and individual station adjustments on the controllers. B.After system has been installed, make final adjustments prior to inspection by Engineer. C. Completely flush system to remove debris from lines by removing nozzles from heads and turning on system. Replace nozzles and check operation of system, zone by zone, to determine that there is no debris left in the heads to obstruct proper operation. If any heads do not operate properly, repeat operation by removing nozzles of heads not operating properly and reflushing. D. Check sprinklers for proper operation and proper alignment for direction of throw. E. Check each section of heads for operating pressure and balance to other sections by use of flow adjustment on top of each valve. F. Check nozzling for proper coverage. Prevailing wind conditions or slopes may indicate that arc of angle or trajectory of spray should be modified. Change nozzles to provide correct coverage. G. After system is thoroughly flushed and ready for operation, each section of sprinklers must be adjusted to control pressure at heads. Use the following method, one section at a time: 1. Remove last head on section and install temporary riser above grade. Install tee with pressure gauge attached on top of riser and reinstall head with nipple onto tee. 2. Correct operating pressure range at last head of each section shall be as per manufacturer's recommendations. 3. After replacing heads, at grade, tamp thoroughly around head. H. The Contractor shall flush the main lines from dead end fittings for a minimum of five (5) minutes under a full head of pressure. 3.6 CLEANUP During work, keep premises neat and orderly. Remove trash and debris from site daily as work progresses. After completion of work level and rake clean disturbed areas, leaving in an orderly condition acceptable to Designer.IRRIGATION NOTESL0.2AAP AAPJSH 3/8" WIDE x 1 2 " DEEP MAX TOOLED JOINT NOTES: 1.EXPANSION JOINTS SHALL BE PROVIDED @ 15' INTERVALS MAX. AND AT MEETING OF ALL PAVEMENTS, WALLS, STEPS, VERTICAL SURFACES, BACKS OF CURB, SIGN POSTS, LIGHT POLES, ETC... 2.1/4" RADIUS ON ALL TOOLED EDGES. 3.EXPANSION JOINTS RECESSED 1/4" BELOW FINISH GRADE OF WALK. 4.CONTROL JOINTS SHALL BE PROVIDED @ 5' INTERVALS MAX. SELF-LEVELING SEALANT, COLOR TO MATCH COLOR OF ADJACENT PAVING / BACKER ROD, NO BOND TO SEALANT / 1 2" POLYSTYRENE FOAM EXPANSION JOINT SIDEWALK JOINT DETAIL Scale: N.T.S. 1/2" EXPANSION JOINT 3/8" CONTROL JOINT 95% COMPACTED SUBGRADE95% COMPACTED SUBGRADE 1/2" 54 -0 MIN.1 -04 DIA, 4 -0 HIGH TYPICALCENTER STEEL PIPE BOLLARD IN CONCRETE PIER THE OVERHEAD DOOR BOLLARDS SHOULD BE IN LINE WITH THE JAMB FACE OF THE OVERHEAD DOOR OPENING SO THAT NO PART OF THE BOLLARD PROJECTS INTO THE OPENING NO DOOR AT SIM. CONDITION GROUT FILLED DOMED TOP UNLESS NOTED OTHERWISE HOT-DIPPED GALV., SCH 40, STD. STEEL PIPE BOLLARD - FILLED SOLID W/ CONCRETE, PAINT PER ELEV. GC TO PROVIDE AND INSTALL CLOSED EYE BOLT HOOKS TO BACK SIDE OF ALL BOLLARDS AT OVERHEAD DOORS. REFER TO DETAIL 20/F1 FOR MORE INFORMATION 1 -0 DIA. GENERAL NOTES: 1.MAINTAIN 3 -9 MIN. CLEAR. BTW. FACE OF BLDG. AND FACE OF PIPE BOLLARD - CRITICAL DIM. 2.MIN. CONC. COMPRESSIVE STRENGTH: 3,500 PSI AT 2 DAYS. 3.MAX. WATER-CEMENTITIOUS RATIO: 0.5. SLUMP LIMIT: 5 PLUS OR MINUS 1, MEASURED AT POINT OF PLACEMENT. MAX. COARSE AGGREGATE SI=E: 1 MIN. CEMENTITIOUS MATERIALS CONTENT: 470 LBS PER CUBIC YARD. AIR CONTENT: 5.5.3CLRTYP3 CLR CMU BOND BEAM WITH 1 5 CONT 5 AT 12 OC 4 5 CONT REINF SOLID GROUT CMU AND VOID BELOW GRADE  CMU WITH 5 VERT AT 4 OC, TERMINATE WITH STD ACI HOOK, TYP CL OF POLE AND PIER 3 CLR1 -01 -01 -0 4 -0 SIGN POST AND POST FOUNDATION BY OTHERS COORDINATE PLACEMENT WITH CMU FOUNDATION MARKB1 MARKB2 MARKB1 MARKB2 2 -0 MINSIGN BY OTHERS  NORMAL WEIGHT CMU BELOW GRADE SECTION CONCRETE FOOTING, REF STRUCTURAL FINISH GRADE NICHIHA N-2 SMOOTH FACE CMU PREFINISHED COPING USE CHARCOAL GRAY TREATED WOOD BLOCKING NICHIHA ESSENTIAL STARTER FLASHING MONUMENT SIGN BASE AND POWER FOR SIGN BY GENERAL CONTRACTOR. 2 1 GAUGE GALVANI=ED HAT CHANNEL SLOPE  -46 -15 -09 -06 -MONUMENT SIGNAGE -415 -0ELEVATION COMPLETE AUTO CARETM FINISH GRADE NICHIHA N-2 PREFINISHED COPING USE CHARCOAL GRAY ALL SIGNS AND NECESSARY SUPPORT S BY SIGN VENDOR. CONTACT AGI SIGNS FOR COORDINATION: TRAVIS HODGES 00-77-76, EXT 3339 SECTION This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCSITE DETAILS 1 OF 2 C09 PAVEMENT SECTIONS N.T.S. PAVEMENT SECTION DETAILS FOR SCHEMATIC PURPOSES ONLY. SECTIONS TO BE VERIFIED WITH FINAL GEOTECHNICAL REPORT PRIOR TO CONSTRUCTION PAVEMENT SECTIONS N.T.S.4 NOTES: 1.METHODS AND MATERIALS SHALL CONFORM TO VDOT STANDARDS. 2.GEOTECHNICAL ENGINEER TO PROVIDE PAVEMENT SECTION RECOMMENDATION USING THE FOLLOWING DESIGN CRITERIA: - 20-YEAR DESIGN LIFE - 50-PASSENGER VEHICLES PER BUILDING, PER DAY - 2 TRUCKS/DELIVERIES PER BUILDING, PER DAY - AASHTO HS-20 LOADING STANDARD 3.GEOTECHNICAL ENGINEER TO REVIEW AND PROVIDE PAVEMENT SECTION RECOMMENDATION APPLICABLE TO INDIVIDUAL SITE CONDITIONS. ALL VEHICLE-RATED SECTIONS SHALL BE DESIGNED TO AASHTO HS-20 LOADING CRITERIA. 4.ALL PUBLIC ROADS ARE SUBJECT TO FINAL PAVEMENT DESIGN APPROVAL BY APPLICABLE STATE AND LOCAL GOVERNMENT. 5.SEE 033000 CAST-IN-PLACE CONCRETE SPECIFICATION FOR CONCRETE INSTALLATION INFORMATION,SUSTAINABILITY RE4UIREMENTS, AND EMBODIED CARBON LIMITS. CONCRETE SHOWN IN CIVIL DRAWINGS IS TO BE CONSIDERED WHEN CALCULATING THE PROJECT-WIDE EMBODIED CARBON REDUCTION. 6.IN LIEU OF HMA, WARM MIX ASPHALT WMA IS PREFERRED AND SHALL BE PSECIFIED BY DESIGNER WHERE AHJ ALLOWABLE AND WHERE WMA IS READILY AVAILABLE AT LOCAL PRODUCTION PLANTS. STANDARD DUTY MINIMUM CONCRETE PAVEMENT SECTION NOT TO SCALE 6.0" BASE STONE MATERIAL VDOT SECTION 208 21A/B STONE 5" PORTLAND CEMENT CONCRETE VDOT SECTION 217 HEAVY DUTY MINIMUM CONCRETE PAVEMENT SECTION NOT TO SCALE ADA SYMBOL DETAIL Scale: N.T.S.7 ADA SIGN DETAIL Scale: N.T.S.6 STANDARD CURB & GUTTER DETAIL Scale: N.T.S.STANDARD CURB DETAIL Scale: N.T.S.9 ADA RAMP DETAIL Scale: N.T.S.2 BOLLARD DETAIL N.T.S.1 6.0" BASE STONE MATERIAL VDOT SECTION 208 21A/B STONE 7" PORTLAND CEMENT CONCRETE VDOT SECTION 217 4 HEIGHTMONUMENT SIGN DETAIL Scale: N.T.S.3 USED TIRE STORAGE 5 -4 M.O. 2 - LIGHT FIXTURE, TYP BLACK, MOUNT AT 7 -0 AFG 10 -0 OVERALL4 -04 -02 -4 15 -7 4 -02 -4 6 1/2 16 - M.O.  ENCLOSURE GATE  20 A6 4 THUS, SIM. 6 A6.1 22 A6.11 -02 YD DUMPSTERYD DUMPSTER SLOPEAWAYPOST FOOTING BEYOND, TYPICAL CL CL 6 1/2CLCL CL 4 A6.1 5 A6.1 TYP. 1 A6.1 19 A6.1 HIGH 1 -0 OVERALL 16 - -10 -0 OVERALL7 A6.1 TIRE ENCLOSURE TRASH ENCLOSURE 4 A6.1 5 A6.1 TYP. 5 A6.1TYP. 5 A6.1TYP.This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.CALL "MISS UTILITY" 811 11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCSITE DETAILS 2 OF 2 C10 NOTE: FOR REFERENCE OF KEY COMPONENTS RELATED TO INTERIOR COMBINE RISER TRASH & TIRE ENCLOSURE DETAIL Scale: N.T.S.11  AGGREGATE STONE BASE APPLY TACK COAT SEALER TO CONCRETE AT TRANSITION ASPHALT PAVEMENT CONCRETE PAVEMENT CONCRETE/ ASPHALT PAVEMENT TRANSITION DETAIL Scale: N.T.S.10 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCPROFFERS 1 OF 2 C11 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCPROFFERS 2 OF 2 C12 ALTA 1 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCLIGHTING PLANPSL 1 This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNCHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT‹ 2025 KIMLEY-HORN AND ASSOCIATES, INC.11400 COMMERCE PARK DR., SUITE 400, RESTON, VA 20191PHONE: 703-674-1300 FAX: 703-674-1350WWW.KIMLEY-HORN.COM2/27/2026111125000JMHJMHCMHVIRGINIAFREDERICK COUNTYFIRESTONE COMPLETEAUTO CAREPREPARED FOR=AREMBA GROUP, LLCLIGHTING DETAILSPSL 2