Loading...
HomeMy WebLinkAbout2025-11-21.Showers_Fire Marshal November 21, 2025 Mr. S. Mark Showers Frederick County Fire Marshal 1080 Coverstone Drive Winchester, VA 22602 RE: FCPS 4th High School Job No. 3805.0 Dear Mr. Showers: Please find enclosed a resubmittal on the above referenced project for your review and comment. Below is a list of the items included in this submittal: • Revised Site Plan dated November 21, 2025 We received comments from Adam Hounshell dated November 1, 2025 and have addressed them as follows: General Comments: 1. Comment: Additional fire hydrant in the loop around faculty parking to provide water supply for that portion of the building. Response: An additional fire hydrant has been provided in the requested location. 2. Comment: Fire department access along the building in the loop around the faculty parking shall be a minimum width of 26 feet for aerial apparatus access. Response: Understood. The drive aisle in the loop area is now 26’ wide. 3. Comment: Fire hydrant to provide water supply for the bathrooms/ storage building at the baseball/ softball fields. Hydrant shall be within 300 feet of the structure. Response: An additional fire hydrant has been provided within 300 feet of this structure. 4. Comment: Minimum width of 20 feet for fire department access to the bathrooms/ storage building at the baseball/ softball fields. Response: The paved trail accessing the bathrooms/storage building at the baseball/softball fields has been widened to 20 feet for fire department access. It has been widened to provide the maximum 150’ dead-end fire apparatus road to get within 150’ of the far end of the structure. The fencing in this area has also been reconfigured to provide fire truck access including widening the gate to 20’. FCPS 4th High School Page 2 of 2 Job No. 3805.0 5. Comment: Fire hydrants shall be within 3 feet of curbs or reasonably placed. (referring to hydrant in the school bus parking area) Response: This fire hydrant is placed reasonably close to the sidewalk while also keeping the gate valve located in grass. Proposed fire lane striping along this sidewalk also ensures adequate access. Please note that an additional fire hydrant has been added near the faculty/staff parking lot. 6. Comment: Add fire lane signs and markings as outlined in the site plan application. Fire lane markings shall be provided in all fire lane locations or other approved means of identifying the fire department access. Life Safety Plan/Appendix D for reference. Response: Fire lane signs and markings are proposed as requested. Thank you for your time in reviewing this project. If you have any questions, please feel free to contact me by phone or email (info@foresightdesignservices.com). Sincerely, Foresight Design Services Trevor M. Kimzey, P.E. Director of Engineering Enclosures cc: Kevin Kenney, FCPS (via email) Matt Waguespack, VLK (via email) TMK/lew