Loading...
HomeMy WebLinkAbout46-25 Middletown Elem Site PlanMIDDLETOWN ELEMENTARY SCHOOL 190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 BUILDING EXPANSION   SITE PLAN   PIN 91-A-78A DB 610 / PG 160 BACK CREEK DISTRICT - FREDERICK COUNTY, VIRGINIA ORIG. SUBMISSION DATE OCTOBER 17, 2025 REVISED SUBMISSION DATE JANUARY 23, 2026 U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS0000.dwg PLOTTED: 1/23/2026 3:24 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 12-12-2024 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKLOCATION MAP Scale: 1" = 2000' CALL 1-800-552-7001 CALL BEFORE YOU DIG ALWAYS CALL 811 BEFORE YOU DIG IN VIRGINIA SECTION 56-265.17 REQUIRES THREE WORKING DAYS NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR BLAST VIRGINIA UTILITY PROTECTION SERVICE, INC. TICKET NUMBER(S): PREPARED BY: PENNONI ASSOCIATES INC. 117 East Piccadilly Street Winchester, VA 22601 T 540.667.2139 F 540.665.0493 PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NORTHSUBMITTED FOR REVIEW 1-23-2026 CS0000 TOTAL SHEETS 42    1-23-2026  SITE LOCAL UTILITIES: FREDERICK CO. VIRGINIA TOWN OF MIDDLETOWN MIDDLETOWN, VIRGINIA 22645 ZONING ADMINISTRATOR - (540) 869-2226 WATER / SEWER - (540) 869-7731 CITY OF WINCHESTER PUBLIC UTILITIES 15 N. CAMERON STREET WINCHESTER, VIRGINIA 22601 (540) 667-1815 RAPPAHANNOCK ELECTRIC CO-OP 137 KELLEY COURT FRONT ROYAL, VIRGINIA 22630 (540) 662-2037 VERIZON 404 HILLANDALE LANE WINCHESTER, VIRGINIA 22602 (540) 665-3156 COMCAST COMMUNICATIONS 195 RAINVILLE ROAD WINCHESTER, VIRGINIA 22602 (540) 504-0942 WASHINGTON GAS 350 HILLANDALE LN. WINCHESTER, VIRGINIA 22602 (540) 868-7913 SHEET INDEX SHEET SHEET TITLE CS0000 COVER SHEET CS0001 GENERAL NOTES AND LEGENDS CS0002 KEY MAP & SITE DEVELOPMENT SUMMARY CS1000 EXISTING CONDITIONS AND DEMOLITION PLAN CS2000 EROSION & SEDIMENT CONTROL NARRATIVE CS2100 EROSION AND SEDIMENT CONTROL PLAN PH I CS2200 EROSION AND SEDIMENT CONTROL PLAN PH II CS2500 EROSION AND SEDIMENT CONTROL DETAILS CS2501 EROSION AND SEDIMENT CONTROL DETAILS CS4000 SITE IMPROVEMENT PLAN (OVERALL) CS4001 SITE PLAN (BLDG. EXPANSION) CS4002 SITE PLAN (RECREATION AREAS) CS4003 SITE PLAN (KITCHEN & PARENT LOOP) CS4004 SITE PLAN (BUS LOOP & ENTRANCE) CS4005 SITE PLAN (MUSTANG LN) CS4006 PAVING PLAN CS4101 GRADING PLAN (BLDG. EXPANSION) CS4102 GRADING PLAN (RECREATION AREAS) CS4103 GRADING PLAN (KITCHEN & PARENT LOOP) CS4104 GRADING PLAN (BUS LOOP & ENTRANCE) CS4105 GRADING PLAN (MUSTANG LN) CS4500 SITE DETAILS CS4501 SITE DETAILS CS5100 WATER MAIN PROFILES (CITY OF WINCHESTER) CS5150 WATER DETAILS (CITY OF WINCHESTER) CS5200 SANITARY SEWER PROFILES CS5600 SEWAGE PUMP STATION (PRIVATE) CS6100 STORM SEWER PROFILES CS6101 STORM SEWER PROFILES CS7000 LANDSCAPE PLAN CS7500 LANDSCAPE NOTES, DETAILS, AND CALCULATIONS CS7501 TREE INVENTORY AND NOTES CS8000 LIFE SAFETY PLAN CS8100 PHOTOMETRIC PLAN CS8101 PHOTOMETRIC DETAILS CS9200 PRE RE-DEVELOPMENT DRAINAGE PLAN CS9300 POST RE-DEVELOPMENT DRAINAGE PLAN CS9401 MS-19 & VRRM COMPLIANCE CS9402 STORMWATER MANAGEMENT NARRATIVE & STUDY POINT ANALYSIS CS9501 DRY POND COMPUTATIONS & DETAILS CS9502 BIO-RETENTION B COMPUTATIONS & DETAILS CS9503 DRY SWALE A COMPUTATIONS & DETAILS PREVIOUS APPROVALS SITE PLAN SP#31-87 SCHOOL ADDITION SP#47-97 MODULAR CLASSROOMS SP#03-25 PREPARED FOR: OWNER/DEVELOPER PO BOX 3508 WINCHESTER, VIRGNIA 22604 (540) 662-3888 EXT. 88249 FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANCOVER SHEET RESPONSIBLE LAND DISTURBER THE RESPONSIBLE LAND DISTURBER IS THAT PARTY RESPONSIBLE FOR CARRYING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. NAME:_____________________________________________________ CERTIFICATION #:___________________________________________ DATE: _____________________________________________________ APPROVED BY FREDERICK COUNTY ZONING ADMINISTRATOR APPROVAL VALID FOR  5  YEARS. ________________________________________________________________________________ APPROVED BY DATE PLAN REVIEW TRACKING 10-29-2025 PLAN, FM, PW, INSP, VDOT, CoW,ToM 11-3-2025 TOWN OF MIDDLETOWN (APPROVAL) 11-18-2025 VDOT (APPROVAL) 12-18-2025 FM (APPROVAL) 1-15-2025 PW & CITY OF WINCHESTER 1-20-2026 PW (APPROVAL) 1-21-2026 CoW (APPROVAL) 1-23-2026 PLAN, INSP GENERAL CONSTRUCTION NOTES 1.THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR AND EQUIPMENT AND PERFORM ALL WORK INCLUDING RESTORATION FOR ALL IMPROVEMENTS SHOWN OR IMPLIED AS NECESSARY FOR THE COMPLETED FACILITY READY FOR USE. UNLESS OTHERWISE NOTED, SPECIFICATIONS FOR ALL WORK TO BE IN ACCORDANCE WITH APPLICABLE STANDARDS AND CONSTRUCTION SPECIFICATIONS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION, VIRGINIA DEPARTMENT OF HEALTH, ECONOMIC DEVELOPMENT AUTHORITY, AND THE CONTRACT DOCUMENTS. 2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION STAKEOUT. ALL DIMENSIONS, ELEVATIONS AND LOCATIONS SHALL BE VERIFIED IN THE FIELD BY EACH CONTRACTOR PRIOR TO BEGINNING THE WORK. THE ENGINEER WILL APPROVE ALL CUT SHEETS. 3.CONSTRUCTION ACTIVITIES SHALL BE LIMITED TO THE HOURS OF 8:00 AM TO 5:00 PM. 4.ANY UNUSUAL SUBSURFACE CONDITIONS ENCOUNTERED DURING THE COURSE OF THE WORK SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER AND/OR THE OWNER. 5.CONTRACTOR TO OBTAIN, AT HIS EXPENSE, ALL PERMITS REQUIRED OF THIS WORK PRIOR TO COMMENCING CONSTRUCTION AND SHALL FAITHFULLY ADHERE TO THE PERMIT CONDITIONS IMPOSED. 6.ALL GRADING FOR IMPROVEMENTS TO BE CONFINED TO THE PROJECT AREA. ANY WORK PERFORMED OFFSITE IS THE CONTRACTOR'S RESPONSIBILITY. 7.CUTSHEETS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO CONSTRUCTION. ALL CUTSHEETS SHOULD SHOW EXISTING GROUND ELEVATIONS AT CENTERLINE OF UTILITY, STRUCTURE OR ROAD, AND OFFSET HUB ELEVATION. 8.LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING THE EXACT LOCATION, VERTICALLY AND HORIZONTALLY, OF THE UTILITIES PRIOR TO ANY EXCAVATION OR CONSTRUCTION. THE CONTRACTOR SHALL CONTACT "MISS UTILITY" AND ALL APPLICABLE UTILITY COMPANIES FOR CLEARANCE PRIOR TO EXCAVATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADHERING TO THE COMMONWEALTH OF VIRGINIA UNDERGROUND UTILITY DAMAGE PREVENTION ACT, CHAPTER 10, TITLE 56 OF THE CODE OF VIRGINIA. 9.CONTRACTOR SHALL BE RESPONSIBLE FOR IMPLEMENTING AND MAINTAINING ALL EROSION AND SEDIMENT CONTROL MEASURES NECESSARY DURING CONSTRUCTION IN ACCORDANCE WITH CURRENT STATE AND LOCAL REGULATIONS. DISTURBED AREAS SHALL NOT REMAIN DENUDED FOR MORE THAN SEVEN (7) CALENDAR DAYS WHEN CONSTRUCTION IS NOT IN PROGRESS. DURING CONSTRUCTION, ALL STORM SEWER INLETS SHALL BE PROTECTED BY INLET PROTECTION, AND SHALL BE MAINTAINED AND MODIFIED AS REQUIRED BY CONSTRUCTION PROGRESS. CONTRACTOR SHALL CONTACT THE COUNTY BUILDING INSPECTIONS OFFICE AT (540) 636-9973 TO SCHEDULE INSPECTIONS. 10.CONTRACTOR SHALL PROVIDE ADEQUATE MEANS OF CLEANING MUD FROM TRUCKS AND/OR OTHER EQUIPMENT PRIOR TO ENTERING PUBLIC STREETS AND/OR EXISTING PARKING LOTS AND OTHER PAVED AREAS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CLEAN STREETS, ALLAY DUST, AND TO TAKE WHATEVER MEASURES NECESSARY TO ENSURE THAT THE STREETS ARE MAINTAINED IN A CLEAN, MUD AND DUST FREE CONDITION AT ALL TIMES. 11.ANY STREET OR UTILITIES DAMAGED BY CONTRACTOR OR SUB-CONTRACTOR SHALL BE SOLE RESPONSIBILITY OF THE PRIMARY CONTRACTOR AND PROPERLY AND IMMEDIATELY REPAIRED BY THE CONTRACTOR. SUCH REPAIRS SHALL BE TO RESTORE THE ORIGINAL CONDITION, IN COMPLIANCE WITH THE UTILITY OWNER'S, STATE'S, COUNTY'S OR CITY'S CONSTRUCTION STANDARDS & SPECIFICATIONS, AND TO THE SATISFACTION OF THE UTILITY OWNER'S INSPECTOR. 12.ALL PRE-CAST CONCRETE STRUCTURES SHALL BE A MINIMUM 4000 PSI AT 28 DAYS. 13.THE CONTRACTOR IS RESPONSIBLE FOR ADJUSTMENT OF ALL UTILITY BOXES, VAULTS, OR OTHER APPURTENANCES TO NEW FINISHED GRADE ELEVATIONS. 14.CONTRACTOR TO RELOCATE ALL SIGNS AND UTILITIES REQUIRED FOR THIS WORK. 15.ANY PLANNED DISRUPTIONS OF OR TIE INS TO EXISTING UTILITIES SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY OWNER. WITH THE EXCEPTION OF EMERGENCIES, THERE SHALL BE A MINIMUM OF 24 HOURS NOTICE GIVEN BY THE CONTRACTOR TO ALL RESIDENTIAL, COMMERCIAL, AND INDUSTRIAL UTILITY USERS AFFECTED BY UTILITY INTERRUPTIONS. 16.THE UNAUTHORIZED USE OF WATER WITHOUT DUE COMPENSATION IS ILLEGAL. NO PERSON SHALL CONNECT TO OR DO ANY WORK ON THAT PORTION OF THE SYSTEM OWNED BY THE TOWN UNLESS WRITTEN AUTHORIZATION IS RECEIVED PRIOR TO COMMENCING WORK. 17.CONSTRUCTION LIMITS SHALL BE PROPERTY LINES OR AS INDICATED BY PLAN REQUIREMENTS AND SHALL BE STAKED OR FLAGGED IN THE FIELD PRIOR TO CONSTRUCTION. 18.CONSTRUCTION SHALL CONFORM TO THE AMERICAN WITH DISABILITIES ACT (ADA) REQUIREMENTS. 19.REGISTERED LAND DISTURBER TO SUBMIT REPORTS TO BUILDING INSPECTOR ON A REGULAR BASIS AS REQUIRED BY FREDERICK COUNTY. 20.THE CONTRACTOR SHALL COORDINATE WITH THE INDIVIDUAL LOT OWNERS TO RELOCATE THE EXISTING MAIL BOXES THAT ARE AFFECTED BY THE PROPOSED IMPROVEMENTS. 21.ALL UTILITIES WILL BE LOCATED UNDERGROUND. 22.TEST PITS ARE REQUIRED ON ALL FREDERICK WATER / FCSA OWNED SEWER AND WATER LINES AS NEEDED AND REQUIRED BY THEIR STANDARDS AND SPECIFICATIONS AND OR AS DIRECTED BY THEIR INSPECTOR. 23.FIELD ADJUSTMENTS TO FREDERICK WATER / FCSA INFRASTRUCTURE SHALL BE AS REQUIRED BY THE FREDERICK WATER INSPECTOR'S REQUIREMENTS. 24.EXISTING MANHOLE FRAMES AND COVERS AND VALVE BOXES AND COVERS TO REMAIN SHALL BE ADJUSTED OR RECONSTRUCTED, AS NECESSARY, TO MATCH FINISHED GRADES. 25.VDOT EROSION AND SEDIMENT CONTROL CONTRACTOR CERTIFICATION IS REQUIRED. FIRE AND RESCUE 1. BURNING OF CONSTRUCTION DEBRIS AND CLEARING AND GRUBBING DEBRIS ON SITE IS PROHIBITED. 2. ACCESS FOR EMERGENCY VEHICLES MUST BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION. TEST HOLE ......................... BUILDING WALL ..................... DOOR LOCATION ..................... LIMITS OF GRADING ................. BENCHMARK ......................... PROPOSED CG-6R TREE LINE ......................... TREE .............................. SANITARY STRUCTURE LABEL .......... WATER METER ....................... SPOT SHOT ......................... SIGN .............................. FIRE HYDRANT ...................... STREET LIGHT ...................... UTILITY POLE ...................... WATER VALVE ....................... TRAFFIC SIGNAL POLE ............... FENCE LINE ........................ UNDERGROUND TELEPHONE ............. OVERHEAD TELEPHONE ................ UNDERGROUND ELECTRIC .............. OVERHEAD ELECTRIC ................. STORM STRUCTURE LABEL ............. GAS LINE .......................... WATERMAIN ......................... SANITARY SEWER .................... STORM SEWER ....................... EDGE OF PAVEMENT .................. CURB AND GUTTER ................... CONTOURS .......................... STREET CENTERLINE ................. PROPERTY LINE ..................... 24 LEGEND TRANS.CG-6 EXISTING 24 RW RWRECLAIM WATERMAIN ..................RW RW S DD WATERLINE TO BE REMOVED.................. RECLAIMED WATERLINE TO BE REMOVED STORM SEWER TO BE REMOVED............ PAVEMENT TO BE REMOVED.................... CITY OF WINCHESTER AND TOWN OF MIDDLETOWN PUBLIC UTILITIES: 1.THE CONTRACTOR SHALL ADHERE TO THE STANDARDS AND SPECIFICATIONS IN EFFECT AT THE TIME OF CONSTRUCTION. 2.THE CONTRACTOR SHALL COORDINATE WITH AND ARRANGE FOR INSPECTION BY PUBLIC UTILITIES. 3.THE CONTRACTOR SHALL TIE-IN A NEW SEWER LINE TO AN EXISTING MANHOLE BY CORE DRILLING THE MANHOLE. 4.WHEN AN EXISTING WATER (OR FORCED SEWER) MAIN IS TAPPED FOR THE INSTALLATION OF A NEW LINE: 4.A.CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIAL. 4.B.THE CONTRACTOR MUST: 4.B.1.MAKE APPLICATION AND PAY DEPOSIT 4.B.2.MARK THE TAP LOCATION 4.B.3.COORDINATE INSTALLATION WITH THE ENGINEERING-ASSISTANT. 5.EXACT LOCATIONS OF WATER AND SEWER SERVICES ON NEW LINES ARE TO BE COORDINATED WITH THE INSPECTOR. 6.PUBLIC UTILITIES SHALL FURNISH AND INSTALL ALL WATER METERS THROUGH 2" IN SIZE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO HAVE THE METER BOX ASSEMBLY INSTALLED CORRECTLY. BEFORE A PERMANENT METER IS INSTALLED: 6.A.THE METER BOX, WITH ITS FRAME AND COVER, MUST BE PROPERLY ALIGNED WITH THE COPPERSETTER. 6.B.THE FRAME AND COVER SHALL BE SET TO FINAL GRADE. 6.C.THE DISTANCE BETWEEN THE TOP OF THE COVER AND THE COPPERSETTER SHALL BE 24 INCHES. 6.D.ALL COMPONENTS OF THE METER BOX ASSEMBLY SHALL BE IN PROPER WORKING ORDER. 7.FOR WATER AND SEWER SERVICES THAT CONNECT TO EXISTING LINES: 7.A.THE LOCATION OF THE SERVICE LATERAL IS TO BE COORDINATED WITH THE ENGINEERING ASSISTANT. 7.B.SERVICE TAPS MAY BE MADE BEFORE PAYMENT OF FEES; HOWEVER, TAP FEES MUST BE PAID PRIOR TO SETTING METERS OR ISSUANCE OF BUILDING PERMITS. 7.C.PROVISION AND INSTALLATION OF METERS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY'S PUBLIC SERVICES STANDARDS MANUAL. 7.D.CONTRACTOR SHALL MAKE ALL TAPS AND SERVICE LINE INSTALLATIONS. THE CONTRACTOR SHALL FURNISH AND INSTALL THE METER VAULT ASSEMBLY. PUBLIC UTILITIES WILL INSTALL THE METER. 7.E.CONTRACTOR WILL INSTALL ALL SEWER LATERALS. 8.ANY WATER SERVICE LINE MUST HAVE A BACKFLOW PREVENTION ASSEMBLY (DETECTOR DOUBLE CHECK VALVE OR RPZ, AS REQUIRED). THE ASSEMBLY MUST MEET ASSE STANDARD NO. 1015 OR 1013. 9.ALL FIRE LINES SHALL HAVE A BACKFLOW PREVENTION ASSEMBLY (DETECTOR DOUBLE CHECK VALVE OR RPZ, AS REQUIRED). THE ASSEMBLY SHALL MEET ASSE STANDARD NO. 1048 OR 1047. 10.PUBLIC UTILITIES TO REVIEW THE MECHANICAL PLAN(S) FOR DESIGN AND MATERIAL APPROVAL OF: 1) THE DOMESTIC WATER METER AND ITS BACKFLOW PREVENTION DEVICE, AND/OR 2) THE FIRE SERVICE LINE'S BACKFLOW PREVENTION DEVICE BUILDING & INSPECTIONS 1.NO CONSTRUCTION MAY BEGIN UNTIL A PROPER BUILDING PERMIT HAS BEEN APPROVED AND ISSUED BY THE BUILDING OFFICIAL AND ZONING ADMINISTRATOR AND ALL FEES PAID. NO NEW STRUCTURE MAY BE LAWFULLY OCCUPIED WITHOUT A CERTIFICATE OF OCCUPANCY FROM THE DEPARTMENT. 2.BUILDINGS SHALL COMPLY WITH VIRGINIA UNIFORM STATEWIDE BUILDING CODE AND THE FOLLOWING SUPPLEMENTS TO THIS WHICH ARE: 2020 NATIONAL ELECTRICAL CODE, 2021 INTERNATIONAL BUILDING CODE, 2021 INTERNATIONAL PLUMBING CODE, 2021 INTERNATIONAL MECHANICAL CODE, 2021 INTERNATIONAL FUEL CODE, 2021 INTERNATIONAL ENERGY CONSERVATION CODE, 2021 INTERNATIONAL RESIDENTIAL CODE, 2021 EDITION USBC CODE, ICC A 117.1-2017 STANDARDS FOR ACCESSIBILITY AND USABLE BUILDINGS AND FACILITIES. FIRE MARSHAL 1.EMERGENCY ACCESS ROAD MAY NOT BE USED TO STORE EQUIPMENT OR MATERIALS. 2.EMERGENCY ACCESS ROAD SHALL NOT BE BLOCKED BY GATES, MATERIALS, OR EQUIPMENT FOR AN EXTENDED PERIOD OF TIME NOR AFTER HOURS OR WHILE THE CONTRACTOR IS NOT ON SITE. PLANNING & DEVELOPMENT 1.SITE LIGHTING WILL BE IN COMPLIANCE WITH SECTION 165-201.07 OUTDOOR LIGHTING OF THE FREDERICK COUNTY ZONING ORDINANCE. 2.ALL LIGHTING SHALL BE DOWN CAST AND FULL CUT-OFF. 3.LIGHT POLES SHALL BE A MAXIMUM OF 25' IN HEIGHT. 4.NO PULL BOXES FOR LIGHTS SHALL BE IN PAVEMENT. FEMA FLOODPLAIN INFORMATION: FIRM #: 51069C0320E DATE: 1-29-2021 ZONE: X U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS0001.dwg PLOTTED: 1/23/2026 3:24 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 01-03-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS0001 TOTAL SHEETS 42    1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOLBUILDING EXPANSIONSITE PLAN190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTGENERAL NOTES AND LEGENDS DEVELOPER / OWNER FREDERICK COUNTY PUBLIC SCHOOLS PO BOX 3085 WINCHESTER, VIRGNIA 22604 (540) 662-3888 EXT. 88249 PROPERTY SUMMARY ADDRESS 190 MUSTANG LANE MIDDLETOWN, VIRGINIA 22645 PARCEL OWNER FREDERICK COUNTY SCHOOL BOARD OF VIRGINIA TAX MAP TM 91-A-78A EXISTING ZONING RA CURRENT USE EDUCATIONAL INSTITUTION PROPOSED USE EDUCATIONAL INSTITUTION TOTAL SITE AREA 15.0020 AC DISTURBED AREA 7.09 AC TOTAL DEVELOPED LAND AREA 13.90 AC FLOOR AREA CALCULATIONS TOTAL GROUND FLOOR AREA 93,379 SF (70,373 SF EX BLDG +23,006 SF BUILDING EXPANSION) TOTAL GROSS FLOOR AREA 106,926 SF (70,373 SF EX BLDG +36,553 SF BUILDING EXPANSION) TOTAL LOT AREA 653,488 SF F.A.R 0.16 MAX F.A.R. ALLOWED N/A BUILDING HEIGHT (45' MAX) EXISTING BUILDING (1-STORY) 11'-0" GYM / CLASSROOM EXPANSION (2-STORY)25'-6" KITCHEN EXPANSION (1-STORY)11'-0" SETBACKS REQUIRED PROVIDED GYM & CLASSROOM EXPANSION FRONT 60'N/A SIDE 100'±144.6' R/W (I-81)100'±124.1' KITCHEN EXPANSION FRONT 60'N/A SIDE 100'±224.7' R/W (I-81)100'N/A EQUIPMENT SHED (ACCESORY) FRONT N/A N/A SIDE 15'±73.5' R/W (I-81)60'N/A IMPERVIOUS AREAS EXISTING IMPERVIOUS AREA 4.97 AC NEW IMPERVIOUS AREA 1.26 AC TOTAL IMPERVIOUS AREA 6.23 AC. OPEN SPACE CALCULATIONS (15% MIN.) EXISTING OPEN SPACE 10.03 AC. (66.9%) NEW TOTAL OPEN SPACE 8.75 AC (58.3%) PARKING CALCULATIONS EXISTING REQ.PROVIDED CARS 110 19 (1 SP / FACULTY & STAFF MEMBER + 4 VISITOR)149 BUS 13 N/A 19 TOTAL (CARS + BUS)123 N/A 168 HC SPACES 4 (4 VAN)6 (1 VAN)8 (6 VAN) LOADING SPACES 1 1 (1 FOR EACH STR WITH 100,000 FLOOR AREA)1 WATER & SEWER DEMANDS (CITY OF WINCHESTER) A NEW 8" WATER MAIN SHALL BE EXTENDED TO THE GYMNASIUM / CLASSROOM EXPANSION WHERE A NEW 3 INCH DOMESTIC AND 6 INCH FIRE METER VAULT WILL BE INSTALLED. PROJECTED WATER SERVICE DEMANDS = 98 GPM (DOMESTIC) & 425 GPM (FIRE) ONLY THE GYMNASIUM AND CLASSROOM EXPANSION WILL BE SERVED BY THE NEW METER. THE EXISTING WATER METER SHALL REMAIN UNALTERED AND IN-SERVICE. PR E - T R E A T M E N T FO R E B A Y SWM DETENTION POND (FOR QUANTITY ONLY)BIORE TEN T ION FAC I L I T Y BEX B-BALL COURT(ASPHALT)PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPT MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX DRY DETENTION POND EX BIO-RET AWP1FHWP1WP1WP1WP1WP1WP1WP1WP1WP1WP1TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1WARV KI T E X P 1, 1 2 7 S F GYM N A S I U M LFL = 7 2 8 . 8 0 'CLASSROOMS(2 -STORY )LFL = 7 2 8 .80 ' GRASS R E C A R E A ±30,800 S F B L D G E X P A N S I O N 21 , 8 7 9 S F 10'x12' STORAGE SHED W/ 11'x13' CONC. SLAB RESERVED AREA FUTR. FUEL ISLAND U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS0002.dwg PLOTTED: 1/23/2026 3:24 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SU%MITTE' )2R RE9IE: 1 &S TOTAL SHEETS 42    1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOLBUILDING EXPANSIONSITE PLAN190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTKEY MAP & SITE DEVELOPMENT SUMMARY 00 80'160' GRAPHIC SCALE 1"=80' .E< MA3 &S &S1 &S1 &S11 &S &S1 &S &S1 &S &S1 730 735 7317 3 2 73373473 5 7 3 6 7377367 3 7 73 8 739740 741 742 740 73973 8737 736 735 7347337327307297287277267257247237227217207197 1 9 7207 2 1 72 2 72 3 7 2 4 72572 6 727 729 728 729724 725 726 72772872973073173373874074 5 744743742741740739738737736735734733738739740733734735736737739 738737 740737738 73974074274174374474 4 743 740 743 7427417 4 0 74 2 7 4 1 74 0 739 738 74 1 7 4 0739738 7407397387377367377417 4 2 742742742741741 7 4 2 74 1 7 4 073973 8 73 7 74274174073973873 773673 57347 3 3 7 3 2 731730742735 730728727742 742743 72473874273 8 739 740 73973873973 7 73 6 733 73 4 735 7327317337207177177 1 8 718719721722723724715720712713714716717718719721722723724F.F.E. (742.79)COCOCOF.F.E. (742.78)24" RCP SCOCOCO24" RCP 15" RCP WV WV ASPHALT ASPHALTASPHALTASPHALTASPHALTEX B-BALL COURT(ASPHALT)PLAY "A" C O N C . W A L K CONC. WALK CONC. WALKC O N C . W A L K CONC. S/W C O N C . W A L K C O N C . W A L K CONC. WALKCONC. WALKCONC. WALKCONC. WALKC O N C . W A L K BENCH CONC. WALK24" RCP18" RCPINV. (734.31)INV. (735.08) 12" RCP 12" R C P 1 5 " RCP18" RCPF.F.E. (742.81)6" PVC12" PVCF.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)#190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPT15" RCP12" RCP12"PVC18" RCPASPHALT 18' FIRE LANE16' FIRE LANEEX. GAS MAIN (2X)EX. GAS MAIN (2X)EX. 50' GAS ESMTDB 234 PG 359SMH EX-ARIM = 742.72IN = 735.62OUT = 735.52SMH EX-B RIM = 738.97 IN = 733.97 OUT = 733.87 3 2 8 . 3 5 ' - 8 " P V C @ 0 . 4 7 % P R I V A T E SMH EX-C RIM = 733.76 IN = 730.26 OUT = 730.16125.54 ' - 8 " PVC @ 1 .03%PRIVATE SMH EX-D RIM = 735.87 IN = 728.87 OUT = 728.77 ±905' TO PUMP STATION MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57 " E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'S 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1N 33° 57' 54" W 453.18' ASPHALT B A S K E T B A L L C O U R T (A S P H A L T ) PLAY "B" PLAY "C" PLAY "D" PLAY "E" PLAY "F" PLAY "G"PLAY "H"INTERSTATE 81(LIM ITED ACCESS ROW)EX CLF - BACK-STOP B/M 9048 - IRT W/CAP N=7061934.08' E=11551262.54' EL=741.89' B/M 9047 - IRT W/CAP N=7062201.73' E=11551165.52' EL=736.31' CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 EX. 6" DIP W/L EX. 6" W/M EX 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 (END PORTION TO BE VACATED) EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200EX. 6" W/L (CITY OF WINCHESTER)6" W/M FUEL I S L A N D 15' SETBACK (ACC. USE 165-401.07-C) 100' SETBACK (PRINCIPAL USE 165-401.07-A) 15' SETBACK (ACC. USE 165-401.07-C) 100' SETBACK (PRINCIPAL USE 165-401.07-A)100' SETBACK(PRINC IPAL USE 165-401 .07-A)60' SETBACK(ACC. USE 165-401 .07-C)15' SETBACK (ACC . USE 165 -401 .07 -C )100' SETBACK (PR INC IPAL USE 165 -401 .07 -A ) 5' SETBACK (PRKG 165-202.01-D (6))10' SETBACK (PRKG 165-202 .01-D (6)) 5' SETBACK (PRKG 165-202.01-D (6))5' SETBACK (PRKG 165 -202 .01 -D (6 ) )DSEX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 TAN K 60' SETBACK (PRINCIPAL USE 165-401.07-A)EX 6" W/L (APPROX)TP#1 (03-22-2025) DOMW - 6" DIP COVER = ±4.4' TP#2 (03-22-2025) DOMW - 6" DIP COVER = ±4.1' EX GRATE TOP = 737.36 INV IN = 733.56 INV OUT = 733.56 EX OUTLET INV OUT = 731.69 8" HDPE @ 2.75% INV OUT = 740.40 INV IN = 740.81 101.91' - 6" PVC RDNPIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX TOP = 741.78INV IN = 735.68 (6")INV IN = 734.38 (15")INV OUT = 734.28 (18")INV = 710.67' INV = 714.88' 121.7 8 ' - 3 6 " C M P @ 3 . 4 6 % EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 198 E X R O O F D R A I N S K E T C H E D A P P R O X ( P E R R E C O R D ) EX OUTLET INV OUT = 729.61 (SILTED) EX DRY DETENTION POND EX SWM RISER TOP = 733.84 INV IN = 729.14 INV OUT = 729.04 INV IN = 729.08 PLAY "G" INV OUT = 728.35 EX BIO-RET A EX CURB INLET TOP = 739.89 INV IN = 734.49 INV OUT = 734.19 EX CURB INLET TOP = 735.54 INV IN = 730.84 INV OUT = 730.49 EX GRATE INLETTOP = 739.95INV IN = 737.65INV OUT = 737.55EX CURB INLETTOP = 742.46INV OUT = 737.96EX CURB INLET TOP = 736.62 INV IN = 732.32 INV OUT = 731.77 12" R C P DUMPSTER PADCONC. RAMPEX GRATE INLETTOP = 740.60INV IN = 736.80INV OUT = 736.70EX TOP = 742.33INV IN = 735.83INV IN = 735.58INV OUT = 735.53CANOPYEX GV W/ 6 BOLLARDS EX GV EX GLMEX. 50' GAS ESMTDB 234 PG 359EX GLM EX GLM 12" R C P 60' SETBACK(ACC. USE 165-401 .07-C)10' SETBACK (PRKG 165-202 .01-D (6))100' SETBACK(PRINC IPAL USE 165-401 .07-A) 100' SETBACK (PRINCIPAL USE 165-401.07-A)15' SETBACK (ACC . USE 165 -401 .07 -C )100' SETBACK (PR INC IPAL USE 165 -401 .07 -A )5' SETBACK (PRKG 165 -202 .01 -D (6 ) )WP1FHWP1 WP1 WP1 WP1 WP1WP1WP1WP1WP1WP1 20' EMERGENCY ACCESS RD GRAVEL20'EX. 5' CO N C S / W RAMP RAMPRAMP20' COW WATERESMTE X . F I R E L I N E - A - 6 " C L - 5 2 D I P EX . 1 " D O M W C T S P E T E X , C O M M , D A T A , A L A R M EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. E X . 3 2 0 L F S A N F M ( P R I V ) 1. 2 5 " S D R - 1 1 H D P E EX. ELEC PANEL & PS CONTROLLER (W/GEN RECEPTACLE) EX. 6' X 6' GRAVEL PAD FOR PORT. GEN 240V / 6,500 WATT EX 6' HT - FENCEGATETEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) 6' HT - FENCEEX 6' HT - FENCEEX SAN PS 1 EX 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 (BEGIN PORTION TO BE VACATED) XXXX XX X X X X X X XXX X X (6) EX TREES TO BE REMOVED (6) EX TREES TO BE REMOVED (4) EX TREES TO BE REMOVED EX TREE TO BE REMOVED EX 2,290 SF PLAY AREA TO BE RELOCATED EX 1,556 SF PLAY AREA TO BE RELOCATED EX 1,230 SF PLAY AREA TO BE RELOCATED EX 596 SF PLAY AREA TO BE RELOCATED EX 313 SF PLAY AREA TO BE RELOCATED EX 2,954 SF PLAY AREA TO BE RELOCATED EX 2,857 SF PLAY AREA TO BE RELOCATED EX 271 SF PLAY AREA TO BE RELOCATED EX 30 SF BENCH PAD TO BE REMOVED EX 4,409 SF ASPHALT BASKETBALL COURT TO BE REMOVED EX 797 SF CONC S/W TO BE REMOVED EX 2,965 SF FIRELANE TO BE REMOVEDPORTION OF EX SWLK TO REMAIN24,433 SF EX TREES TO BE REMOVED 7,600 SF EX TREES TO BE REMOVED EX 148 LF 6" PVC TO BE REMOVED X X (2) EX TREES TO BE REMOVED X (3) EX BBALL HOOPS TO BE REMOVED X EX SIGN TO BE REMOVED X X (2) EX SIGNS TO BE REMOVED X EX TREE TO BE REMOVED X EX SIGN TO BE REMOVED EX 40 LF BACKSTOP TO BE REMOVED EX 263 SF CONC S/W TO BE REMOVED EX. CURB & GUTTER TO BE REMOVED EX. 3 LF RET. WALL TO BE REMOVED EX TREE TO BE REMOVED X X X (3) EX TREES TO BE REMOVED X EX TREE TO BE REMOVED PORTION OF EX 6" W/L TO BE REMOVED (APPROX 40') PORTION OF EX 6" W/L TO BE ABANDONED IN PLACE (APPROX 210') X EX TREE TO BE REMOVED EX 160 SF CONC SWLK TO BE REMOVED U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS1000.dwg PLOTTED: 1/23/2026 3:25 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 01-03-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 40'80' GRAPHIC SCALE 1"=40' SU%MITTE' )2R RE9IE: 1 &S1 TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MI''LET2:N ELEMENTAR< S&+22L190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANEXISTING CONDITIONS AND DEMOLITION PLAN LONG TERM MAINTENANCE AND REPAIR PLAN MOWING: ALL GRASSES SHOULD BE MOWED AT LEAST TWICE EACH YEAR. GRASSES SUCH AS TALL FESCUE SHOULD BE MOWED IN EARLY SUMMER AFTER EMERGENCE OF THE HEADS ON COOL SEASON GRASSES. THEY SHOULD BE MOWED AGAIN IN THE EARLY FALL TO PREVENT SEEDS OF ANNUAL WEEDS FROM MATURING. MOWING OF LEGUMES SUCH AS SERICEA LESPEDEZA AND CROWN VETCH CAN BE PERMITTED TO GROW ON THE DAM OR IN ANY PART OF THE EMERGENCY SPILLWAY. LIMING AND FERTILIZING: THE SOIL SHOULD BE SAMPLED ACCORDING TO RECOMMENDED PROCEDURES AT LEAST ONCE EVERY 4 YEARS. THE SAMPLE SHOULD BE TESTED AT A QUALIFIED SOIL TESTING LABORATORY (SUCH AS THE ONE AT VPI&SU). LIME AND FERTILIZER SHOULD BE APPLIED IN ACCORDANCE WITH RECOMMENDATIONS BASED ON THE TESTS. REPLANTING AND OVER SEEDING: IF VEGETATION COVERS LESS THAN 40% OF THE SOIL SURFACE, LIME, FERTILIZE AND SEED IN ACCORDANCE WITH CURRENT RECOMMENDATIONS FOR NEW SEEDING. IF VEGETATION COVERS MORE THAN 40% BUT LESS THAN 70% OF THE SOIL SURFACE, LIME FERTILIZE AND OVER SEED IN ACCORDANCE WITH CURRENT RECOMMENDATIONS. REMOVING TRASH AND DEBRIS: TRASH, LITTER AND VEGETATION (OTHER THAN GRASS) WILL BE REMOVED AS NEEDED (BUT NO LESS THAN TWO TIMES PER YEAR) TO PREVENT OBSTRUCTION TO THE FLOW OF WATER, TO PREVENT MOVEMENT OF TRASH AND LITTER TO DOWNSTREAM PROPERTIES, TO MAINTAIN THE INTEGRITY OF THE STRUCTURE, TO PROVIDE AN ATTRACTIVE APPEARANCE AND TO MINIMIZE WATER POLLUTION. REMOVING SEDIMENT: SOIL MATERIALS (INCLUDING CLAY, SILT, SAND AND GRAVEL) WILL BE REMOVED BEFORE THE DETENTION POOL LOSES 10% OF THE DESIGNED STORAGE CAPACITY. SEDIMENT DISPOSAL: SEDIMENT DISPOSAL SHOULD BE IN ACCORDANCE WITH CURRENT PROCEDURES FOR DISPOSAL OF SEDIMENT. WHERE REQUIRED BY THE APPROPRIATE AUTHORITIES, THE SEDIMENT WILL BE TESTED FOR APPROPRIATE POLLUTANTS AT THE OWNER'S EXPENSE BEFORE IT IS REMOVED FROM THE POND. REPAIRS: REPAIR SLIDES, SLUMPS AND ERODED AREAS PROMPTLY AND IN A WORKMANLIKE MANNER TRASH RACKS, PIPES, HEADWALLS, ETC. WILL BE MAINTAINED, REPAIRED AND/OR REPLACED AS NEEDED TO MAINTAIN THE INTEGRITY OF THE STRUCTURE. EXPOSED METAL SURFACES WILL BE PAINTED TO MINIMIZE DAMAGE DUE TO RUST. MAINTENANCE INSPECTIONS: THE OWNER WILL BE RESPONSIBLE FOR INSPECTING EACH STORMWATER MANAGEMENT STRUCTURE AFTER EACH SIGNIFICANT RAINFALL. ONCE EACH YEAR A REPRESENTATIVE OF DEQ WILL JOINTLY INSPECT EACH STORMWATER MANAGEMENT STRUCTURE. APPROPRIATE ACTION WILL BE TAKEN TO ENSURE APPROPRIATE MAINTENANCE. ALL MAINTENANCE COSTS WILL BE BORNE BY THE OWNER. WHERE STRUCTURES ARE TO BE MAINTAINED BY MORE THAN ONE PARTY, ALLOCATION OF COSTS WILL BE IN ACCORDANCE WITH TERMS SET FORTH IN THE MAINTENANCE AGREEMENT. KEYS TO LOCKED ACCESS POINTS SHALL BE AVAILABLE TO DEQ PERSONNEL UPON REQUEST. MAINTENANCE RECORDS: THE LANDOWNER, OR SOMEONE DESIGNATED BY THE LANDOWNER, SHALL INSPECT THE DETENTION POND WITHIN 24 HOURS AFTER EACH RAINFALL EVENT OF ONE INCH OR MORE OF RAIN. THE OWNER OR THE DESIGNEE SHALL KEEP WRITTEN RECORDS OF THESE INSPECTIONS. THE RECORDS SHALL ALSO INCLUDE MAINTENANCE AND REPAIRS PERFORMED. COPIES OF THESE RECORDS SHALL BE PROVIDED TO THE COUNTY UPON REQUEST. THE WATER QUALITY FEATURES SHALL NOT BE MODIFIED IN ANY WAY WITHOUT PRIOR APPROVAL BY DEQ AND FREDERICK COUNTY. ·TOPSOIL SHALL BE SPREAD AT A MINIMUM DEPTH OF 4". ·PULVERIZED AGRICULTURAL LIMESTONE SHALL BE INCORPORATED INTO SOIL AT A RATE OF 92 LBS. PER 1000 S.F. (2 TONS PER ACRE). ·FERTILIZE WITH 10-20-10 AT A RATE OF 12 LBS. PER 1000 S.F. (500 LBS. PER ACRE). SEED MIX SHALL CONSIST OF 90% KENTUCKY 31 TALL FESCUE AND 10% KENTUCKY BLUEGRASS APPLIED AT THE RATE OF 200 LBS. PER ACRE. EROSION AND SEDIMENT CONTROL NARRATIVE PROJECT DESCRIPTION THIS PROJECT IS LOCATED IN FREDERICK COUNTY, VIRGINIA. THE SITE IS SITUATED EAST OF ROUTE 11 & APPROXIMATELY 1.5 MILES NORTH OF THE TOWN OF MIDDLETOWN. THE SITE AREA IS 15.00 ACRES AND THE PROPOSED DISTURBED AREA IS APPROXIMATELY 7.09 ACRES. THE PROJECT PROPOSES TO CONSTRUCT A BUILDING EXPANSION, AN ASPHALT PLAY AREA, AND EXPAND & RELOCATE EXISTING PLAYGROUND SPACE. IN ADDITION TO THE BUILDING EXPANSION THIS PROJECT PROPOSES A NEW EMERGENCY ACCESS ROAD ALONG THE REAR OF THE SCHOOL. ADDITIONAL IMPROVEMENTS INCLUDE NEW CONCRETE SIDEWALKS FOR ACCESS TO THE BUILDING EXPANSION & CIRCULATION TO THE REST OF THE SITE AS WELL AS AN ASSOCIATED SWM/BMP FACILITY. EXISTING SITE CONDITIONS THE EXISTING SITE IS MIDDLETOWN ELEMENTARY SCHOOL. THE SITE GENERALLY DRAINS FROM THE BUILDING IN ALL DIRECTIONS. ADJACENT PROPERTY THE PROJECT IS BORDERED TO THE NORTH & WEST BY VACANT LAND ZONED AS RA. TO THE SOUTH IS LAUREL RIDGE COMMUNITY COLLEGE AND TO THE EAST IS INTERSTATE 81. OFF-SITE AREAS THERE ARE NO OFFSITE AREAS PROPOSED FOR DEVELOPMENT OR CONSTRUCTION AS A PART OF THIS PROJECT. SOILS AND GEOLOGY PLEASE REFER TO SHEETS CS9200 & CS9300 FOR SOILS INFORMATION. CRITICAL AREAS CRITICAL AREAS, IF ANY, CONSIST OF 2.5 OR 3:1 SLOPES. THESE SLOPES HAVE THE POTENTIAL FOR GREATER EROSION AND SHALL BE IMMEDIATELY STABILIZED AFTER REACHING FINAL GRADE. NONE HAVE BEEN IDENTIFIED. EROSION AND SEDIMENT CONTROL MEASURES UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONSTRUCTED AND MAINTAINED ACCORDING TO THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA STORMWATER MANAGEMENT HANDBOOK. STRUCTURAL MEASURES THE SEDIMENT TRAP, SEDIMENT BARRIERS AND OTHER MEASURES SHOWN ON THE PLANS INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND-DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. THIS SITE DRAINS TO AN EXISTING STORM WATER MANAGEMENT POND EAST OF THE PROPERTY. EVERY EFFORT SHALL BE MADE TO PREVENT SILT FROM RUNNING OFF THE SITE DURING CONSTRUCTION AND BEING DEPOSITED INTO THE POND. PHASE I: SAFETY FENCE (C-PCM-01) SHALL BE INSTALLED AS SHOWN TO PREVENT CHILDREN AND OTHER PEDESTRIANS FROM ACCESSING THE CONSTRUCTION AREA. CONSTRUCTION ENTRANCE WITH WASH RACK (C-SCM-03) SHALL BE INSTALLED AT THE LOCATION SHOWN ON THE PHASE I PLAN TO PREVENT MUD AND DEBRIS FROM BEING TRACKED ONTO ROADWAYS. DIVERSION DIKE (C-ECM-04) SHALL BE INSTALLED AS SHOWN ON PLANS TO DIRECT SEDIMENT-LADEN RUNOFF TOWARDS THE SEDIMENT TRAPS. SUPER SILT FENCE (C-PCM-04) SHALL BE INSTALLED AS SHOWN ON PLANS TO FILTER RUNOFF FROM DISTURBED AREAS BEFORE IT LEAVES THE SITE. INLET PROTECTION (C-SCM-04) SHALL BE INSTALLED AS SHOWN ON PLANS TO FILTER POTENTIALLY SEDIMENT-LADEN RUNOFF BEFORE IT LEAVES THE SITE. TEMPORARY SEDIMENT TRAP (C-SSM-11) SHALL BE INSTALLS AS SHOWN ON PLANS TO INTERCEPT SEDIMENT-LADEN RUNOFF BEFORE IT LEAVES THE SITE. TEMPORARY SEEDING (C-SSM-09) SHALL BE PLACED ON ALL CRITICAL SLOPES (3:1 OR GREATER) AND AS NEEDED TO STABILIZE DISTURBED AREAS. PHASE II: ALL CONTROLS INSTALLED IN PHASE I SHOULD REMAIN UNTIL THE SITE IS STABILIZED. INLET PROTECTION WITH STONE COMBINATION (C-SCM-04) SHALL BE RELOCATED WHEN OUTLET STRUCTURE INSTALLED. CHECK DAMS (C-SCM-07) SHALL BE INSTALLED AS SHOWN ON THE PLANS TO SLOW RUNOFF AND HELP TO MITIGATE EROSION. SOIL STABILIZATION MATTING (C-SSM-05) SHALL BE INSTALLED ON ANY DISTURBED SLOPES STEEPER THAN 3:1 - NONE ARE PROPOSED. PERMANENT SEEDING (C-SSM-10) SHALL BE PLACED ON ALL CRITICAL SLOPES (3:1 OR STEEPER) AND AS NEEDED TO STABILIZE DISTURBED AREAS. VEGETATIVE MEASURES PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS ON ANY PORTION OF THE SITE WITHIN SEVEN (7) DAYS AFTER FINAL GRADE IS REACHED. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN (7) DAYS TO ANY DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE, BUT WHICH WILL REMAIN DORMANT FOR LONGER THAN FOURTEEN (14) DAYS. PERMANENT SOIL STABILIZATION SHALL BE APPLIED TO ALL AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN SIX (6) MONTHS. SOIL THAT HAS BEEN STOCKPILED SHALL BE SURROUNDED WITH SILT FENCE AND PROTECTED BY MULCH AND/OR TEMPORARY VEGETATION IMMEDIATELY AFTER GRADING. ALL EARTH BERMS, DAMS, DIKES, DIVERSIONS AND SEDIMENT TRAP EMBANKMENTS ARE TO BE MACHINE-COMPACTED, IMMEDIATELY SEEDED, AND MULCHED (HAY MULCH OR STRAW) FOR TEMPORARY AND/OR PERMANENT VEGETATIVE COVER WITHIN FIVE (5) DAYS AFTER GRADING. MANAGEMENT STRATEGIES CONSTRUCTION SHALL BE SEQUENCED SUCH THAT GRADING OPERATIONS WILL BEGIN AND END AS QUICKLY AS POSSIBLE. THE SITE SUPERINTENDENT SHALL BE RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF ALL EROSION AND SEDIMENT CONTROL MEASURES. MAINTENANCE OF THESE MEASURES THROUGHOUT THE PROJECT IS CRITICAL TO PROGRAM EFFECTIVENESS. AFTER AREAS UP-SLOPE OF THESE CONTROLS HAVE BEEN STABILIZED, THE CONTROLS SHALL BE CLEANED UP AND REMOVED, AT THE DIRECTION OF THE FREDERICK COUNTY INSPECTOR. ALL CUT AND FILL SLOPES ARE TO BE SEEDED AND MULCHED WITHIN FIVE (5) DAYS OF COMPLETION OF GRADING. CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION. SLOPES THAT ARE FOUND TO BE ERODING EXCESSIVELY WITHIN ONE YEAR OF PERMANENT STABILIZATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE STABILIZING MEASURES UNTIL THE PROBLEM IS CORRECTED. DRAINAGE SWALES SHALL BE STABILIZED WITH CHECK DAMS UNTIL VEGETATION HAS BEEN WELL ESTABLISHED, AT WHICH TIME THE CHECK DAMS SHALL BE REMOVED. CONCENTRATED RUNOFF SHALL NOT FLOW DIRECTLY DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME, OR SLOPE DRAIN STRUCTURE. WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED. ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT-LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. WHERE CONSTRUCTION VEHICLES ACCESS ROUTES OR INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE SEDIMENT TRANSPORT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE LOCAL PROGRAM AUTHORITY. TRAPPED SEDIMENT AND DISTURBED AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. DEVICES LISTED ABOVE ARE CONSIDERED MINIMUM EROSION AND SEDIMENT CONTROLS. ADDITIONAL CONTROL MEASURES MAY BE NECESSARY DUE TO CONTRACTOR PHASING OR OTHER UNFORESEEN CONDITIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADDITIONAL MEASURES TO THOSE SHOWN, AS NEEDED, IN ORDER TO CONTROL EROSION AND CONTAIN SEDIMENT ON SITE. ALL MEASURES SHALL BE INSTALLED ACCORDING TO THE STANDARDS AND SPECIFICATIONS IN THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. (VESCH) ANY CHANGES MADE TO THIS PLAN MUST BE RESUBMITTED FOR APPROVAL WITHOUT EXCEPTION. MAINTENANCE ALL CONTROL MEASURES SHALL BE INSPECTED DAILY BY THE SITE SUPERINTENDENT OR HIS REPRESENTATIVE AND WITHIN 24 HOURS AFTER ANY STORM EVENT GREATER THAN 0.5 INCHES OF RAIN PER 24 HOUR PERIOD. ANY DAMAGED STRUCTURAL MEASURES ARE TO BE REPAIRED BY THE END OF THE DAY. SEEDED AREAS SHALL BE CHECKED REGULARLY TO ENSURE THAT A GOOD STAND OF GRASS IS MAINTAINED. ALL AREAS SHALL BE FERTILIZED AND RESEEDED AS NEEDED UNTIL GRASS IS ESTABLISHED. TRAPPED SEDIMENT IS TO BE REMOVED AS REQUIRED TO MAINTAIN 50% TRAP EFFICIENCY AND DISPOSED OF BY SPREADING ON SITE. GRAVEL OUTLETS SHALL BE CHECKED REGULARLY FOR SEDIMENT BUILD-UP. IF THE GRAVEL OUTLET IS CLOGGED BY SEDIMENT, IT SHALL BE REMOVED AND CLEANED OR REPLACED IMMEDIATELY. THE CONTRACTOR IS RESPONSIBLE FOR KEEPING EXISTING PUBLIC ROADS IN A CLEAN, DUST AND MUD FREE, CONDITION AT ALL TIMES. PERMANENT STABILIZATION ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE STABILIZED WITH PERMANENT SEEDING IMMEDIATELY FOLLOWING FINAL GRADING. SEEDING SHALL BE DONE ACCORDING TO STANDARD AND SPECIFICATION (C-SSM-10) OF THE VIRGINIA STORMWATER MANAGEMENT HANDBOOK. PERMANENT STABILIZATION IS DEFINED AS 90% UNIFORM COVERAGE ON THE ENTIRE SITE, ABILITY TO INHIBIT EROSION AND MATURE ENOUGH TO SURVIVE, INCLUDING 2-3 INCH CUTTINGS. PHASES OF LAND DISTURBANCE ACTIVITIES 1.MANDATORY PRE-CONSTRUCTION CONFERENCE SHALL BE SCHEDULED AS REQUIRED BY REGULATIONS. 2.CLEARING AND GRUBBING FOR SEDIMENT CONTROL DEVICES ONLY. 3.INSTALLATION OF ALL PHASE I EROSION & SEDIMENT CONTROL DEVICES.* 4.OBTAIN COUNTY INSPECTOR APPROVAL. 5.ROUGH GRADE SITE. 6.RESTORATION AND STABILIZATION OF DISTURBED AREAS. 7.REMOVE ALL EROSION & SEDIMENT CONTROL MEASURES WITH THE APPROVAL OF THE INSPECTOR. CONSTRUCTION SEQUENCE 1.CONDUCT PRE-CONSTRUCTION MEETING. 2.INSTALL PHASE I E&SC MEASURES AS THE FIRST STEP, PRIOR TO CONSTRUCTION. 3.PERFORM ONSITE GRADING AND OTHER ONSITE CONSTRUCTION EFFORTS. 4.INSTALL PHASE II E&SC MEASURES AS SITE IMPROVEMENTS ARE MADE AND INFRASTRUCTURE IS INSTALLED. 5.RESTORE AND STABILIZE DISTURBED AREAS AS NEEDED AND REQUIRED DURING CONSTRUCTION. 6.COMPLETE ALL CONSTRUCTION EFFORTS AND PERMANENTLY STABILIZE THE SITE. 7.REMOVE ALL EROSION & SEDIMENT CONTROL MEASURES PER INSPECTOR APPROVAL. 9VAC25-875-560. MINIMUM STANDARDS. AN EROSION AND SEDIMENT CONTROL PLAN CONSISTENT WITH THE FOLLOWING CRITERIA, TECHNIQUES, AND METHODS SHALL BE SUBMITTED TO THE VESMP AUTHORITY OR VESCP AUTHORITY FOR REVIEW AND APPROVAL: 1.PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN 14 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN ONE YEAR. 2.DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILES AND BORROW AREAS SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL STOCKPILES ON SITE AS WELL AS BORROW AREAS AND SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE. 3.A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON DENUDED AREAS NOT OTHERWISE PERMANENTLY STABILIZED. PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT IS UNIFORM, IS MATURE ENOUGH TO SURVIVE, AND WILL INHIBIT EROSION. 4.SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS, AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND-DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. 5.STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES, AND DIVERSIONS IMMEDIATELY AFTER INSTALLATION. 6.SEDIMENT TRAPS AND SEDIMENT BASINS SHALL BE DESIGNED AND CONSTRUCTED BASED UPON THE TOTAL DRAINAGE AREA TO BE SERVED BY THE TRAP OR BASIN. a.THE MINIMUM STORAGE CAPACITY OF A SEDIMENT TRAP SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA AND THE TRAP SHALL ONLY CONTROL DRAINAGE AREAS LESS THAN THREE ACRES. b.SURFACE RUNOFF FROM DISTURBED AREAS THAT IS COMPRISED OF FLOW FROM DRAINAGE AREAS GREATER THAN OR EQUAL TO THREE ACRES SHALL BE CONTROLLED BY A SEDIMENT BASIN. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT BASIN SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA. THE OUTFALL SYSTEM SHALL, AT A MINIMUM, MAINTAIN THE STRUCTURAL INTEGRITY OF THE BASIN DURING A 25-YEAR STORM OF 24-HOUR DURATION. RUNOFF COEFFICIENTS USED IN RUNOFF CALCULATIONS SHALL CORRESPOND TO A BARE EARTH CONDITION OR THOSE CONDITIONS EXPECTED TO EXIST WHILE THE SEDIMENT BASIN IS UTILIZED. 7.CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION. SLOPES THAT ARE FOUND TO BE ERODING EXCESSIVELY WITHIN ONE YEAR OF PERMANENT STABILIZATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE STABILIZING MEASURES UNTIL THE PROBLEM IS CORRECTED. 8.CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME, OR SLOPE DRAIN STRUCTURE. 9.WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED. 10.ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT-LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. 11.BEFORE NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS OR PIPES ARE MADE OPERATIONAL, ADEQUATE OUTLET PROTECTION AND ANY REQUIRED TEMPORARY OR PERMANENT CHANNEL LINING SHALL BE INSTALLED IN BOTH THE CONVEYANCE CHANNEL AND RECEIVING CHANNEL. 12.WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS SHALL BE TAKEN TO MINIMIZE ENCROACHMENT, CONTROL SEDIMENT TRANSPORT, AND STABILIZE THE WORK AREA TO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NONERODIBLE MATERIAL SHALL BE USED FOR THE CONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USED FOR THESE STRUCTURES IF ARMORED BY NONERODIBLE COVER MATERIALS. 13.WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES MORE THAN TWICE IN ANY SIX-MONTH PERIOD, A TEMPORARY VEHICULAR STREAM CROSSING CONSTRUCTED OF NONERODIBLE MATERIAL SHALL BE PROVIDED. 14.ALL APPLICABLE FEDERAL, STATE, AND LOCAL REQUIREMENTS PERTAINING TO WORKING IN OR CROSSING LIVE WATERCOURSES SHALL BE MET. 15.THE BED AND BANKS OF A WATERCOURSE SHALL BE STABILIZED IMMEDIATELY AFTER WORK IN THE WATERCOURSE IS COMPLETED. 16.UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: a.NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. b.EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. c.EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF-SITE PROPERTY. d.MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. e.RESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THIS CHAPTER. f.APPLICABLE SAFETY REQUIREMENTS SHALL BE COMPLIED WITH. 17.WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SHALL APPLY TO INDIVIDUAL DEVELOPMENT LOTS AS WELL AS TO LARGER LAND-DISTURBING ACTIVITIES. 18.ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE VESCP OR VESMP AUTHORITY. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. 19.PROPERTIES AND WATERWAYS DOWNSTREAM FROM DEVELOPMENT SITES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION, EROSION, AND DAMAGE DUE TO INCREASES IN VOLUME, VELOCITY, AND PEAK FLOW RATE OF STORMWATER RUNOFF FOR THE STATED FREQUENCY STORM OF 24-HOUR DURATION IN ACCORDANCE WITH THE FOLLOWING STANDARDS AND CRITERIA. STREAM RESTORATION AND RELOCATION PROJECTS THAT INCORPORATE NATURAL CHANNEL DESIGN CONCEPTS ARE NOT MANMADE CHANNELS AND SHALL BE EXEMPT FROM ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MANMADE CHANNELS: a.CONCENTRATED STORMWATER RUNOFF LEAVING A DEVELOPMENT SITE SHALL BE DISCHARGED DIRECTLY INTO AN ADEQUATE NATURAL OR MANMADE RECEIVING CHANNEL, PIPE, OR STORM SEWER SYSTEM. FOR THOSE SITES WHERE RUNOFF IS DISCHARGED INTO A PIPE OR PIPE SYSTEM, DOWNSTREAM STABILITY ANALYSES AT THE OUTFALL OF THE PIPE OR PIPE SYSTEM SHALL BE PERFORMED. b.ADEQUACY OF ALL CHANNELS AND PIPES SHALL BE VERIFIED IN THE FOLLOWING MANNER: (1)THE APPLICANT SHALL DEMONSTRATE THAT THE TOTAL DRAINAGE AREA TO THE POINT OF ANALYSIS WITHIN THE CHANNEL IS 100 TIMES GREATER THAN THE CONTRIBUTING DRAINAGE AREA OF THE PROJECT IN QUESTION; OR (2)(A) NATURAL CHANNELS SHALL BE ANALYZED BY THE USE OF A TWO-YEAR STORM TO VERIFY THAT STORMWATER WILL NOT OVERTOP CHANNEL BANKS NOR CAUSE EROSION OF CHANNEL BED OR BANKS. (b)ALL PREVIOUSLY CONSTRUCTED MANMADE CHANNELS SHALL BE ANALYZED BY THE USE OF A 10-YEAR STORM TO VERIFY THAT STORMWATER WILL NOT OVERTOP THE STORMWATER'S BANKS AND BY THE USE OF A TWO-YEAR STORM TO DEMONSTRATE THAT STORMWATER WILL NOT CAUSE EROSION OF CHANNEL BED OR BANKS; AND (c)PIPES AND STORM SEWER SYSTEMS SHALL BE ANALYZED BY THE USE OF A 10-YEAR STORM TO VERIFY THAT STORMWATER WILL BE CONTAINED WITHIN THE PIPE OR SYSTEM. c.IF EXISTING NATURAL RECEIVING CHANNELS OR PREVIOUSLY CONSTRUCTED MANMADE CHANNELS OR PIPES ARE NOT ADEQUATE, THE APPLICANT SHALL: (1)IMPROVE THE CHANNELS TO A CONDITION WHERE A 10-YEAR STORM WILL NOT OVERTOP THE BANKS AND A TWO-YEAR STORM WILL NOT CAUSE EROSION TO THE CHANNEL, THE BED, OR THE BANKS; (2)IMPROVE THE PIPE OR PIPE SYSTEM TO A CONDITION WHERE THE 10-YEAR STORM IS CONTAINED WITHIN THE APPURTENANCES; (3)DEVELOP A SITE DESIGN THAT WILL NOT CAUSE THE PREDEVELOPMENT PEAK RUNOFF RATE FROM A TWO-YEAR STORM TO INCREASE WHEN RUNOFF OUTFALLS INTO A NATURAL CHANNEL OR WILL NOT CAUSE THE PREDEVELOPMENT PEAK RUNOFF RATE FROM A 10-YEAR STORM TO INCREASE WHEN RUNOFF OUTFALLS INTO A MANMADE CHANNEL; OR (4)PROVIDE A COMBINATION OF CHANNEL IMPROVEMENT, STORMWATER DETENTION, OR OTHER MEASURES THAT IS SATISFACTORY TO THE VESCP OR VESMP AUTHORITY TO PREVENT DOWNSTREAM EROSION. d.THE APPLICANT SHALL PROVIDE EVIDENCE OF PERMISSION TO MAKE THE IMPROVEMENTS. e.ALL HYDROLOGIC ANALYSES SHALL BE BASED ON THE EXISTING WATERSHED CHARACTERISTICS AND THE ULTIMATE DEVELOPMENT CONDITION OF THE SUBJECT PROJECT. f.IF THE APPLICANT CHOOSES AN OPTION THAT INCLUDES STORMWATER DETENTION, THE APPLICANT SHALL OBTAIN APPROVAL FROM THE VESCP OR VESMP AUTHORITY FOR A PLAN FOR MAINTENANCE OF THE DETENTION FACILITIES. THE PLAN SHALL SET FORTH THE MAINTENANCE REQUIREMENTS OF THE FACILITY AND THE PERSON RESPONSIBLE FOR PERFORMING THE MAINTENANCE. g.OUTFALL FROM A DETENTION FACILITY SHALL BE DISCHARGED TO A RECEIVING CHANNEL, AND ENERGY DISSIPATORS SHALL BE PLACED AT THE OUTFALL OF ALL DETENTION FACILITIES AS NECESSARY TO PROVIDE A STABILIZED TRANSITION FROM THE FACILITY TO THE RECEIVING CHANNEL. h.ALL ON-SITE CHANNELS MUST BE VERIFIED TO BE ADEQUATE. i.INCREASED VOLUMES OF SHEET FLOWS THAT MAY CAUSE EROSION OR SEDIMENTATION ON ADJACENT PROPERTY SHALL BE DIVERTED TO A STABLE OUTLET, ADEQUATE CHANNEL, PIPE, OR PIPE SYSTEM OR TO A DETENTION FACILITY. j.IN APPLYING THESE STORMWATER MANAGEMENT CRITERIA, INDIVIDUAL LOTS OR PARCELS IN A RESIDENTIAL, COMMERCIAL, OR INDUSTRIAL DEVELOPMENT SHALL NOT BE CONSIDERED TO BE SEPARATE DEVELOPMENT PROJECTS. INSTEAD, THE DEVELOPMENT, AS A WHOLE, SHALL BE CONSIDERED TO BE A SINGLE DEVELOPMENT PROJECT. HYDROLOGIC PARAMETERS THAT REFLECT THE ULTIMATE DEVELOPMENT CONDITION SHALL BE USED IN ALL ENGINEERING CALCULATIONS. k.ALL MEASURES USED TO PROTECT PROPERTIES AND WATERWAYS SHALL BE EMPLOYED IN A MANNER THAT MINIMIZES IMPACTS ON THE PHYSICAL, CHEMICAL, AND BIOLOGICAL INTEGRITY OF RIVERS, STREAMS, AND OTHER WATERS OF THE STATE. l.ANY PLAN APPROVED PRIOR TO JULY 1, 2014, THAT PROVIDES FOR STORMWATER MANAGEMENT THAT ADDRESSES ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MANMADE CHANNELS SHALL SATISFY THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MANMADE CHANNELS IF THE PRACTICES ARE DESIGNED TO (I) DETAIN THE WATER QUALITY VOLUME AND TO RELEASE IT OVER 48 HOURS; (II) DETAIN AND RELEASE OVER A 24-HOUR PERIOD THE EXPECTED RAINFALL RESULTING FROM THE ONE YEAR, 24-HOUR STORM; AND (III) REDUCE THE ALLOWABLE PEAK FLOW RATE RESULTING FROM THE 1.5-YEAR, TWO-YEAR, AND 10-YEAR 24-HOUR STORMS TO A LEVEL THAT IS LESS THAN OR EQUAL TO THE PEAK FLOW RATE FROM THE SITE ASSUMING THE SITE WAS IN A GOOD FORESTED CONDITION, ACHIEVED THROUGH MULTIPLICATION OF THE FORESTED PEAK FLOW RATE BY A REDUCTION FACTOR THAT IS EQUAL TO THE RUNOFF VOLUME FROM THE SITE WHEN THE SITE WAS IN A GOOD FORESTED CONDITION DIVIDED BY THE RUNOFF VOLUME FROM THE SITE IN THE SITE'S PROPOSED CONDITION, AND SHALL BE EXEMPT FROM ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MANMADE CHANNELS AS DEFINED IN ANY REGULATIONS PROMULGATED PURSUANT TO § 62.1-44.15:28 OF THE CODE OF VIRGINIA (VESMA) OR § 62.1-44.15:54 OR 62.1-44.15:65 OF THE CODE OF VIRGINIA (ESCL). m.FOR PLANS APPROVED ON AND AFTER JULY 1, 2014, THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS OF § 62.1-44.15:52 A OF THE CODE OF VIRGINIA (ESCL) AND THIS SUBDIVISION 19 SHALL BE SATISFIED BY COMPLIANCE WITH WATER QUANTITY REQUIREMENTS IN THE VESMA AND ATTENDANT REGULATIONS, UNLESS SUCH LAND-DISTURBING ACTIVITIES (I) ARE IN ACCORDANCE WITH PROVISIONS FOR TIME LIMITS ON APPLICABILITY OF APPROVED DESIGN CRITERIA IN 9VAC25-875-480 OR GRANDFATHERING IN 9VAC25-875-490, IN WHICH CASE THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS OF § 62.1-44.15:52 A OF THE CODE OF VIRGINIA (ESCL) SHALL APPLY; OR (II) ARE EXEMPT PURSUANT TO § 62.1-44.15:34 G 2 OF THE CODE OF VIRGINIA (VESMA). n.COMPLIANCE WITH THE WATER QUANTITY MINIMUM STANDARDS SET OUT IN 9VAC25-875-600 SHALL BE DEEMED TO SATISFY THE REQUIREMENTS OF THIS SUBDIVISION 19. Middletown Elementary School Site Specific Geologic Data Martinsburg & Oranda Formations: (Shown as Light Blue Areas on Map Below) Description: Martinsburg Formation (Geiger and Keith, 1891). Three lithologic packages are recognized in the Martinsburg (in ascending order): black shale and limestone; sandstone and shale; and sandstone (Rader and Biggs, 1976). The lower unit consists of 200 to 250 feet of black calcareous shale, black aphanic, argillaceous limestone; and thin, light-brown K-bentonites. The bulk of the formation, more than 2800 feet, is composed of olive-green to gray, fine- to medium-grained, lithic sandstone and greenish-gray shale and siltstone. These lithologies occur in base-truncated Bouma cycles. Graded bedding, flute casts, and load casts are common. The upper unit, about 170 feet thick, is brownish-gray, medium- to coarse-grained, quartz sandstone. The lower two-thirds of this sandstone contains near-shore, marine fossils. Oranda Formation (Cooper and Cooper, 1946). Limestone and siltstone. Limestone, medium- to dark-gray, fine-grained, very argillaceous. Siltstone, black to dark-gray; both lithologies silicified where in contact with a K-bentonite. Five K-bentonites identified in the type section (Rader and Read, 1989). Lithologic Constituents ·Major Sedimentary » Clastic » Mudstone » Shale ·Minor Sedimentary » Clastic » Sandstone Sedimentary » Clastic » Siltstone ·Incidental Sedimentary » Carbonate » Limestone U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS2000.dwg PLOTTED: 1/23/2026 3:25 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 01-03-2025 DLFAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS2000 TOTAL SHEETS 42    1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANEROSION & SEDIMENT CONTROL NARRATIVE 730 735 7317 3 2 73373473 5 7 3 6 7377367 3 7 73 8 739740 741 742 740 73973 8737 736 735 7347337327307297287277267257247237227217207197 1 9 7207 2 1 72 2 72 3 7 2 4 72572 6 727 729 728 729724 725 726 72772872973073173373874074 5 744743742741740739738737736735734733738739740733734735736737739 738737 740737738 73974074274174374474 4 743 740 743 7427417 4 0 74 2 7 4 1 74 0 739 738 74 1 7 4 0739738 7407397387377367377417 4 2 742742742741741 7 4 2 74 1 7 4 073973 8 73 7 74274174073973873 773673 57347 3 3 7 3 2 731730742735 730728727742 742743 72473874273 8 739 740 73973873973 7 73 6 733 73 4 735 7327317337207177177 1 8 718719721722723724715720712713714716717718719721722723724LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD EX B-BALL COURT(ASPHALT)PLAY "A" BENCH #190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPT MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57 " E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'S 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1N 33° 57' 54" W 453.18' B A S K E T B A L L C O U R T (A S P H A L T ) PLAY "B" PLAY "C" PLAY "D" PLAY "E" PLAY "F" PLAY "G"PLAY "H"INTERSTATE 81(LIM ITED ACCESS ROW) CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX DRY DETENTION POND PLAY "G" EX BIO-RET AWP1FHWP1WP1WP1WP1WP1WP1WP1WP1WP1WP1TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1 EX B-BALL COURT(ASPHALT)PLAY "A" BENCH #190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPT MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57 " E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'S 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1N 33° 57' 54" W 453.18' B A S K E T B A L L C O U R T (A S P H A L T ) PLAY "B" PLAY "C" PLAY "D" PLAY "E" PLAY "F" PLAY "G"PLAY "H"INTERSTATE 81(LIM ITED ACCESS ROW) CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX DRY DETENTION POND PLAY "G" EX BIO-RET AWP1FHWP1WP1WP1WP1WP1WP1WP1WP1WP1WP1TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1 CE IP ST1 ST2 TS TS TS IP IP IP IP IP SF SSF SSF SSF SF SF SF SF SF SF SF SF TS TS DD ST1 '.A. 1.11 A& ST '.A. 1. A& 62.00'37.00'50.00'27.00' IP IP OP CIP IP EX B-BALL COURT(ASPHALT)PLAY "A" BENCH #190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPT MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57 " E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'S 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1N 33° 57' 54" W 453.18' B A S K E T B A L L C O U R T (A S P H A L T ) PLAY "B" PLAY "C" PLAY "D" PLAY "E" PLAY "F" PLAY "G"PLAY "H"INTERSTATE 81(LIM ITED ACCESS ROW) CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX DRY DETENTION POND PLAY "G" EX BIO-RET AWP1FHWP1WP1WP1WP1WP1WP1WP1WP1WP1WP1TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1 LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD EX B-BALL COURT(ASPHALT)PLAY "A" BENCH #190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPT MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57 " E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'S 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1N 33° 57' 54" W 453.18' B A S K E T B A L L C O U R T (A S P H A L T ) PLAY "B" PLAY "C" PLAY "D" PLAY "E" PLAY "F" PLAY "G"PLAY "H"INTERSTATE 81(LIM ITED ACCESS ROW) CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX DRY DETENTION POND PLAY "G" EX BIO-RET AWP1FHWP1WP1WP1WP1WP1WP1WP1WP1WP1WP1TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1 N2TE SE'IMENT TRA3S 1  MA< N2T %E REM29E' :IT+2UT 3RI2R A33R29AL 2) A )RE'ERI&. &2UNT< 3U%LI& :2R.S INS3E&T2R N2TE INSTALL TEM32RAR< &2NSTRU&TI2N )EN&ING T2 SE&URE T+E SITE )R2M 3E'ESTRIAN A&&ESS. &2NTRA&T2R S+ALL &22R'INATE A&TUAL L2&ATI2N AN' INSTALLATI2N.U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS2100.dwg PLOTTED: 1/23/2026 3:25 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 01-03-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 40'80' GRAPHIC SCALE 1"=40' SU%MITTE' )2R RE9IE: 1 &S1 TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MI''LET2:N ELEMENTAR< S&+22L190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANEROSION AND SEDIMENT CONTROL PLAN PH I SCM-11 TEMPORARY SEDIMENT TRAP ST ST-1 EROSION AND SEDIMENT CONTROL LEGEND NO.TITLE KEY SYMBOL SCM-03 TEMPORARY STONE CONSTRUCTION ENTRANCE CE SCM-04 STORM DRAIN INLET PROTECTION IP PCM-04-4 SILT FENCE SF SOIL STABILIZATION BLANKETS AND MATTING B/MSSM-05 SSM-09 TEMPORARY SEEDING TS TS SSM-10 PERMANENT SEEDING PS PS CRITICAL SLOPES LIMITS OF DISTURBANCE LOD PCM-01 SAFETY FENCE SAF SAF NOTES: SAFETY FENCE TO BE PROVIDED AS NEEDED TO PREVENT UNWARRANTED ACCESS TO CONSTRUCTION AREAS. PCM-04-5 SUPER SILT FENCE SSF 730 735 7317 3 2 73373473 5 7 3 6 7377367 3 7 73 8 739740 741 742 740 73973 8737 736 735 7347337327307297287277267257247237227217207197 1 9 7207 2 1 72 2 72 3 7 2 4 72572 6 727 729 728 729724 725 726 72772872973073173373874074 5 744743742741740739738737736735734733738739740733734735736737739 738737 740737738 73974074274174374474 4 743 740 743 7427417 4 0 74 2 7 4 1 74 0 739 738 74 1 7 4 0739738 7407397387377367377417 4 2 742742742741741 7 4 2 74 1 7 4 073973 8 73 7 74274174073973873 773673 57347 3 3 7 3 2 731730742735 730728727742 742743 72473874273 8 739 740 73973873973 7 73 6 733 73 4 735 7327317337207177177 1 8 7187197217227237247157207127137147167177187197217227237247357347 3 0 7 2 9 7 3 1 728 728728740 7377 3 8 7 3 9 730728729731732733735740734736737738739741725725 725 721722723724 724 724 726727730 735 740 732733 734 736 737 738 739 741 74 2 7327 2 8 7287 3 0 7 2 9 7 3 1 7 3 2 7 3 3 7 3 4 733 736737739739738 7257307237237247267277287297317327337307277287297317327337257307267277287297317 3 8 7 3 7 727 727728728 729 730 728 729 731 73 2 7 3 3 73472572272372472672772 5 72 3 72 4 72 4 72 672 7741740 74 1 735 736 736 736 737 7 3 8 739 730 73 5 74073 1 73 2 73 3 73 4 736 737 73 8 7 3 9 725 730 722723724 726727728729 731732733734 72 5 730 73 5 74 0 72372 4 72 672 7728729 73 173 2 73 3 73 4 7 3 6 73 7 73 8 739 725 730 735 723724 726727728729 731732733734 7207257257217227237237247247257237247267277347403816 EP 37 94 EP 725 730 721722723724726727728729 725 730 721722723724 726727728729 731 7257217227237247267277427437447447437437 4 3 74374374374273073 5 7 2 8 7297317 3 2 7 3 3 73 4 73 6 726726727727 7 2 7 7277277277307287297317327257307357267277287297317327337347367377387397257307267277287297 3 1 7317 3 2 7327 3 3 733740741 740741741725 7257257 2 3 723 724724 725725 721722 723 723724 724 LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD EX B-BALL COURT(ASPHALT)LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 INTERSTATE 81(LIM ITED ACCESS ROW)INTERSTATE 81(LIM ITED ACCESS ROW) EX DRY DETENTION POND EX BIO-RET AWP1FHWP1WP1WP1WP1WP1WP1WP1WP1WP1WP1 EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1 EX B-BALL COURT(ASPHALT)LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 INTERSTATE 81(LIM ITED ACCESS ROW)INTERSTATE 81(LIM ITED ACCESS ROW) EX DRY DETENTION POND EX BIO-RET AWP1FHWP1WP1WP1WP1WP1WP1WP1WP1WP1WP1 EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1 2.4 11.4 11.3 11.2 6.1A 6.1 2.2 4.1 1.2 4.4 11.1 2.1 1.1 4.56" H D P E 12" H D P E24" HDPE1 8 " HDPE 2 4 " H D P E8" HDPE18" HDPE18" HDP E 2 4 " H D P E 15" HDPE6" HDPE1 2 " HDPE12" HDPE2.3 3.1 3.2 2.5 (EX1.2) 4.3 4.2 5.13.2A 12" HDPE12" H D P E 15" HD P E 15" HDPE24" H D P E 12" HDPE 10.2 10.112" RC P C L III 10.0 TO STR 2.4 DA = 0.14 Ac. TO S T R 2 . 3 DA = 0 . 1 2 A c . R D 1 T O E X R O O F L E A D E R S D A = 0 . 1 5 A c .TO STR 4.5DA = 0.56 Ac.TO FOREBAY DA = 0.20 Ac. TO STR 2.2 DA = 0.06 Ac. T O S T R 4 . 1 D A = 0 . 0 4 A c . TO S T R 5. 1 DA = 0. 0 7 A c.TO STR 3.2DA = 0.07 Ac.TO B IO -RET BDA = 0 . 2 8 A c . TO DETENTION POND DA = 1.11 Ac. TO F L U M E DA = 0 . 1 1 A c . T O S T R 6 . 1 D A = 0 . 1 7 A c . TO STR 4.3 DA = 0.07 Ac. TO STR 4.4 DA = 0.42 Ac. ROOF / CANOPY DA = 0.25 Ac. ROOF / CANOPY DA = 0.20 Ac. R O O F / C A N O P Y D A = 0 . 0 9 A c . R D 3 T O E X R O O F L E A D E R S D A = 0 . 6 9 A c . R D 2 T O E X R O O F L E A D E R S D A = 0 . 7 4 A c .RD 5 TO EX ROOF LEADERSDA = 0.04 Ac.RD 4 TO EX ROOF LEADERSDA = 0.04 Ac.TO EX GRATEDA = 0.06 Ac.TO EX GRATEDA = 0.07 Ac.TO EX DRAINDA = 0.05 Ac.T O S T R 1 1 . 3 D A = 0 . 0 4 A c .TO STR 11.4DA = 0.03 Ac.TO STR 11.2DA = 0.04 Ac.T O S T R 1 0 . 2 D A = 0 . 1 6 A c . CE IP PS PS PS B/M B/M B/M B/M B/M IP IP IP SF SF SF SSF SSF SSF SF SF SF SF SF SF SF SF SF SF SF PS PS IP IP IP IP OP OP CIP IPB/M IP IP IP IP PS PS PS PS PS CIP OP CIP IP CD CD CD CD CD CD CD CD U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS2200.dwg PLOTTED: 1/23/2026 3:25 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 40'80' GRAPHIC SCALE 1"=40'SU%MITTE' )2R RE9IE: 1 &S TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MI''LET2:N ELEMENTAR< S&+22L190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANEROSION AND SEDIMENT CONTROL PLAN PH II SCM-12 TEMPORARY SEDIMENT BASIN SB SB SCM-11 TEMPORARY SEDIMENT TRAP ST ST-1 EROSION AND SEDIMENT CONTROL LEGEND NO.TITLE KEY SYMBOL SCM-03 TEMPORARY STONE CONSTRUCTION ENTRANCE CE SCM-04 STORM DRAIN INLET PROTECTION IP PCM-04-4 SILT FENCE SF SOIL STABILIZATION BLANKETS AND MATTING B/MSSM-05 SSM-09 TEMPORARY SEEDING TS TS SSM-10 PERMANENT SEEDING PS PS CRITICAL SLOPES LIMITS OF DISTURBANCE LOD PCM-01 SAFETY FENCE SAF SAF NOTE: SAFETY FENCE TO BE PROVIDED AS NEEDED TO PREVENT UNWARRANTED ACCESS TO CONSTRUCTION AREAS. PCM-04-5 SUPER SILT FENCE SSF SCM-07 ROCK CHECK DAMS CD SCM-05 CULVERT INLET PROTECTION CIP ECM-13 RIPRAP RR Sediment Trap Key Design Aspects Trap Number ST-1 Type (stone weir/pipe)STONE Drainage area 1.11 Ac. Wet Storage Req 75 CY Wet Storage Prov 75 CY (50'x27'x1.5') Dry Storage Req 75 CY Dry Storage Prov Weir Width 5' Pipe Diameter N/A Weir/Pipe Elevations 725.00 Dry Storage Depth 1.50 Embankment Top 726.00 Trap Bottom Ele 722.00 ST-2 STONE 1.50 Ac. 101 CY 101 CY 5' N/A 724.00 1.25 725.00 721.50 106 CY (62'x37'x1.25') Top Width 2'2' Cleanout Ele 723.50 722.75 Wet Storage Depth 1.50 1.25 75 CY (1350 sf x.1.5')106 CY (2294 sf x1.25')U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS2500.dwg PLOTTED: 1/23/2026 3:26 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 01-03-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS2500 TOTAL SHEETS 42    1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOLBUILDING EXPANSIONSITE PLAN190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTEROSION AND SEDIMENT CONTROL DETAILS U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS2501.dwg PLOTTED: 1/23/2026 3:26 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 01-03-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS2501 TOTAL SHEETS 42    1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOLBUILDING EXPANSIONSITE PLAN190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTEROSION AND SEDIMENT CONTROL DETAILS PR E - T R E A T M E N T FO R E B A Y SWM DETENTION POND (FOR QUANTITY ONLY)BIORE TEN T ION FAC I L I TY BEX B-BALL COURT(ASPHALT)#190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPTEX. GAS MAIN (2X)EX. GAS MAIN (2X)EX. 50' GAS ESMTDB 234 PG 359MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57 " E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'S 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1N 33° 57' 54" W 453.18'INTERSTATE 81(LIM ITED ACCESS ROW) CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 EX. 6" DIP W/L EX. 6" W/M EX. 6" W/L (CITY OF WINCHESTER)FUEL I S L A N D 15' SETBACK (ACC. USE 165-401.07-C) 100' SETBACK (PRINCIPAL USE 165-401.07-A) 15' SETBACK (ACC. USE 165-401.07-C) 100' SETBACK (PRINCIPAL USE 165-401.07-A)100' SETBACK(PRINC IPAL USE 165-401 .07-A)60' SETBACK(ACC. USE 165-401 .07-C)15' SETBACK (ACC . USE 165 -401 .07 -C )100' SETBACK (PR INC IPAL USE 165 -401 .07 -A ) 5' SETBACK (PRKG 165-202.01-D (6))10' SETBACK (PRKG 165-202 .01-D (6)) 5' SETBACK (PRKG 165-202.01-D (6))5' SETBACK (PRKG 165 -202 .01 -D (6 ) ) EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 60' SETBACK (PRINCIPAL USE 165-401.07-A) PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX DRY DETENTION POND EX BIO-RET AEX. 50' GAS ESMTDB 234 PG 35960' SETBACK(ACC. USE 165-401 .07-C)10' SETBACK (PRKG 165-202 .01-D (6))100' SETBACK(PRINC IPAL USE 165-401 .07-A) 100' SETBACK (PRINCIPAL USE 165-401.07-A)15' SETBACK (ACC . USE 165 -401 .07 -C )100' SETBACK (PR INC IPAL USE 165 -401 .07 -A )5' SETBACK (PRKG 165 -202 .01 -D (6 ) )WP1FHWP1 WP1 WP1 WP1 WP1WP1WP1WP1WP1WP1EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1 LP 245.6' SB C K 124.1' SBC K KI T E X P 1, 1 2 7 S F GYM N A S I U M LFL = 7 2 8 . 8 0 'CLASSROOMS( 2 -STORY )LFL = 728 . 80 ' GRASS R E C A R E A ±30,800 S F B L D G E X P A N S I O N 21 , 8 7 9 S F 10'x12' STORAGE SHED W/ 11'x13' CONC. SLAB RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A ASPH A L T PLAY A R E A 4,500 S F 24 ' E P 24 ' E P M F L = 7 4 2 . 8 0 '21.6'22'PARENT DROP -OFF / P ICK -UP3,425 SF - HD ASPHALT26'RESERVED AREA FUTR. FUEL ISLAND PUMP STATION AREA ±680 SF GRAVEL PAD 6' BLACK VINYL COATED CHAIN LINK FENCE W / 12' DBL SWING GATE 6' SW L K144.6' SBCKRET. WALL (30 LF)6' SWLK 50.00 ' 90.00'50.00 ' 90.00' ±5,24 0 S F HD A S P H A L T TRASH ENCLOSURE ±210 SF - HD CONC 140.00'220.00'220.00'140.00' BACK UP GENERATOR AREA ±620 SF GRAVEL PAD 6' BLACK VINYL COATED CHAIN LINK FENCE W / 12' DBL SWING GATE REC ELECTRIC SERVICE ±470LF - SCH-40 CONDUIT (COMPLETE TRENCHING DURING SUMMER 2027) TRANSFORMER (FURNISHED BY REC) 7.5' X 7.5' CONC PAD W/6' CLF PR. SAN PUMP STA. (PRIVATE)224.7' SBCK73.5' SBC K 124.2' SBCKREMOVE EX. FH & REPLACE FURNISH TO COW LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD EX B-BALL COURT(ASPHALT)#190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPTEX. GAS MAIN (2X)EX. GAS MAIN (2X)EX. 50' GAS ESMTDB 234 PG 359MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57 " E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'S 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1N 33° 57' 54" W 453.18'INTERSTATE 81(LIM ITED ACCESS ROW) CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 EX. 6" DIP W/L EX. 6" W/M EX. 6" W/L (CITY OF WINCHESTER)FUEL I S L A N D 15' SETBACK (ACC. USE 165-401.07-C) 100' SETBACK (PRINCIPAL USE 165-401.07-A) 15' SETBACK (ACC. USE 165-401.07-C) 100' SETBACK (PRINCIPAL USE 165-401.07-A)100' SETBACK(PRINC IPAL USE 165-401 .07-A)60' SETBACK(ACC. USE 165-401 .07-C)15' SETBACK (ACC . USE 165 -401 .07 -C )100' SETBACK (PR INC IPAL USE 165 -401 .07 -A ) 5' SETBACK (PRKG 165-202.01-D (6))10' SETBACK (PRKG 165-202 .01-D (6)) 5' SETBACK (PRKG 165-202.01-D (6))5' SETBACK (PRKG 165 -202 .01 -D (6 ) ) EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 60' SETBACK (PRINCIPAL USE 165-401.07-A) PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX DRY DETENTION POND EX BIO-RET AEX. 50' GAS ESMTDB 234 PG 35960' SETBACK(ACC. USE 165-401 .07-C)10' SETBACK (PRKG 165-202 .01-D (6))100' SETBACK(PRINC IPAL USE 165-401 .07-A) 100' SETBACK (PRINCIPAL USE 165-401.07-A)15' SETBACK (ACC . USE 165 -401 .07 -C )100' SETBACK (PR INC IPAL USE 165 -401 .07 -A )5' SETBACK (PRKG 165 -202 .01 -D (6 ) )WP1FHWP1 WP1 WP1 WP1 WP1WP1WP1WP1WP1WP1EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1WARV PR. F H A S S M . WATERLINE - A 8" CL-52 DIP 21+00 22+00 2 3 + 0 0 24+00 25+00 26+00 2 7 + 0 0 28+0028+ 7 530+0030+70 10+00 10+4710' COW WATER ESMT (NEW) 20' COW WATER ESMT. (NEW) 10' COW WATER ESMT (NEW)10' COW WATERESMT (NEW)MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 TP#4C (06-07-2025) DOMW - 8" DIP COVER = ±4.2' EX. 8" DIP W/L PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT CITY OF WINCHESTER EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 198 MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 TP#4C (06-07-2025) DOMW - 8" DIP COVER = ±4.2' EX. 8" DIP W/L PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT CITY OF WINCHESTER EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 198 WATERLINE - A 8" CL-52 DIP 18+9719+00 20+00 21+00 U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4000.dwg PLOTTED: 1/23/2026 3:27 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 03-04-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 40'80' GRAPHIC SCALE 1"=40' SU%MITTE' )2R RE9IE: 1 &S TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MI''LET2:N ELEMENTAR< S&+22L190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANSITE IMPROVEMENT PLAN (OVERALL) :ATERLINE A &2NNE&TI2N MUSTANG LN. PRE- T R E A T M E N T F O R E B A Y SWM DETENTION POND (FOR QUANTITY ONLY)BIORE TEN T ION FAC I L I T Y BCOF.F.E. (742.78)SCOCOC O N C . W A L KCONC. WALKCONC. WALK6" PVC12" PVCF.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)15" RCP18" RCPS 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 'INTERSTATE 81(LIM ITED ACCESS ROW) 15' SETBACK (ACC. USE 165-401.07-C) 100' SETBACK (PRINCIPAL USE 165-401.07-A)100' SETBACK(PRINC IPAL USE 165-401 .07-A)60' SETBACK(ACC. USE 165-401 .07-C)10' SETBACK (PRKG 165-202 .01-D (6)) 5' SETBACK (PRKG 165-202.01-D (6)) PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT EX TOP = 741.78INV IN = 735.68 (6")INV IN = 734.38 (15")INV OUT = 734.28 (18")INV = 710.67' INV = 714.88' 121.7 8 ' - 3 6 " C M P @ 3 . 4 6 % GYM N A S I U M LFL = 7 2 8 . 8 0 'CLASSROOMS( 2 -STORY )LFL = 7 2 8 . 8 0 ' B L D G E X P A N S I O N 21 , 8 7 9 S F ASPH A L T PLAY A R E A 4,500 S F 24 ' E P M F L = 7 4 2 . 8 0 '26'PUMP STATION AREA ±680 SF GRAVEL PAD 6' BLACK VINYL COATED CHAIN LINK FENCE W / 12' DBL SWING GATE 8' S W L K 6' SW L K8' SWLK23.5'RAMPRET. WALL ( 3 0 LF )6' SWLK 4" B O L L A R D ( 2 ) W/CH A I N 50.00 ' 90.00'50.00 ' 90.00' 2'R 35'R61'R25'R25'R 88'R 62'R CG- 6 CG-6 ±5,24 0 S F HD A S P H A L T TRAS H E N C L O S U R E ±210 S F - H D C O N C CG-1 2 A CG-12 ABACK UP GENERATOR AREA ±620 SF GRAVEL PAD 6' BLACK VINYL COATED CHAIN LINK FENCE W / 12' DBL SWING GATE 3' G A T E 3' G A T E 8' D B L G A T E 6' H I G H F E N C E 6' SWLK 6 ' SWLK 12.00' 6.00' 6.00' TRANSFORMER (FURNISHED BY REC) 7.5' X 7.5' CONC PAD W/6' CLF DIESELGENERATORCANOPY CANO P Y RI S E R R M L F LMASONRY WALLREF ARCHITECTURE50 ' R 7 0 ' R 24.74'24.74' 20' G R A V E L 6 6 . 2 1 ' - 6 " S D R - 2 6 38.28' - 6" SDR-26 45.56' - 6" SDR-26 PR. S A N P U M P S T A . (PRIV A T E ) PR. SAN LAT - 4" SDR-26 ASSUME 3.0' BELOW LFL PR. SAN LAT - 4" SDR-26 ASSUME 3.0' BELOW LFL BRICK & GROUT EX INV OUTBRICK & GROUT EX INV IN (ROOF DRAINAGE) CORE-DRILL FOR NEW 18" HDPE INV OUT2.4 6.1A 6.1 2.2 4.1 1.2 4.4 2.1 1.1 4.56" H D P E 12" H D P E24" HDPE18" HDPE 2 4 " H D P E8" HDPE18" HDPE18" HD P E 2 4 " H D P E 15" HDPECO1A CO1 CO2 CO3 PS2 1 0 ' ELEC ESMT (REC ) PR E L E C P A N E L & PS C O N T R O L L E R (W/G E N R E C E P T A C L E ) NO PRKG/ FIRE LANE SGN 2.3 3.1 3.2 2.5 (EX1.2) 4.3 4.2 5.1 3.2A 12" HDPE12" H D P E 15" HD P E 15" HDPE24" H D P E 12" HDPE 15'(L) x 2'(W) CONC FLUME TRAPEZOIDAL CHANNEL 2'(W) BOTTOM x 12'(L) CLIA RIPRAP W/ FILTER FABRIC CG-6EOP752' - 1 . 5 " S A N F M - S D R - 1 1 H D P E (PRI V A T E ) BASK E T B A L L G O A L (1 OF 2) NO P R K G / FIRE L A N E S G N NO PRKG/ FIRE LANE SGN REMOVE EX. FH & REPLACE FURNISH TO COW RAMPS 12 :1 MAXW / HR - 1 HAND RA ILSWCOMBINATION VAULT 1 - 3" DOMW METER (COW) 1 - 6" FIRE METER (COW) REMOVE EX FH & REPLACE FURNISH TO COW PR. FH ASSM. 2 1 2 " DOMW SERV. (REF PLUMBING PLANS) 6" FIRE SERV. (REF PLUMBING PLANS) FDC 2 7 + 0 0 28+0028+ 7 5 WATER LI N E - C 8" CL- 5 2 DI P 10+00 10+4720' COW WATER ESMT. (NEW) 8" X 8" TEE 8" GV 8" X 6" RED 8" GV 8" X 6" RED 4" GV 8" X 4" TEE 8" X 6" RED 8" GV W A T E R L I N E - A 8" C L - 5 2 D I P U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4001.dwg PLOTTED: 1/23/2026 3:27 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 07-03-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 20'40' GRAPHIC SCALE 1"=20' ¬0AT&+ &S0AT&+ &S¬S8%0ITTE' )2R RE9IE: 1 &S1 TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 226040I''/ET2:N E/E0ENTAR< S&+22/190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANSITE PLAN (BLDG. EXPANSION) 0AT&+ &S EX B-BALL COURT(ASPHALT)C O N C . W A L K CONC. WALK CONC. WALKCONC. WALKF.F.E. (742.81)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)#190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPT S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1 N 33° 57' 54" W 453.18' CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 15' SETBACK (ACC. USE 165-401.07-C) 100' SETBACK (PRINCIPAL USE 165-401.07-A) 5' SETBACK (PRKG 165-202.01-D (6))DSINTERSTATE 81(LIM ITED ACCESS ROW) EX BIO-RET AEX GRATE INLETTOP = 739.95INV IN = 737.65INV OUT = 737.55EX CURB INLETTOP = 742.46INV OUT = 737.9612" R C P 60' SETBACK(ACC. USE 165-401 .07-C)10' SETBACK (PRKG 165-202 .01-D (6))100' SETBACK(PRINC IPAL USE 165-401 .07-A) 100' SETBACK (PRINCIPAL USE 165-401.07-A)WP1FHWP1 WP1 WP1 WP1 WP1WP1WP1WP1WP1WP1 20' EMERGENCY ACCESS RD GRAVEL20'EX. 5' CO N C S / W RAMPRAMPRAMP20' COW WATERESMTE X . F I R E L I N E - A - 6 " C L - 5 2 D I P E X . 1 " D O M W C T S P E T E X , C O M M , D A T A , A L A R M EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. E X . 3 2 0 L F S A N F M ( P R I V ) 1. 2 5 " S D R - 1 1 H D P E EX. ELEC PANEL & PS CONTROLLER (W/GEN RECEPTACLE) EX. 6' X 6' GRAVEL PAD FOR PORT. GEN 240V / 6,500 WATT EX 6' HT - FENCEGATETEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) 6' HT - FENCEEX 6' HT - FENCEEX SAN PS 1 GRASS R E C A R E A ±30,800 S F RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE ARAMP 140.00'220.00'220.00'140.00' REC ELECTRIC SERVICE ±470LF - SCH-40 CONDUIT (COMPLETE TRENCHING DURING SUMMER 2027) TRANSFORMER (FURNISHED BY REC) 7.5' X 7.5' CONC PAD W/6' CLF 10' UGND UTIL ESMT63.72'63.72'59.96'59.96'100'R120'R20' GRAVE L 1 0 ' ELEC ESMT (REC )RAMP20 ' G R A V E L 10'RAMPS 12 : 1 MAXW / HR - 1 HAND RA ILS U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4002.dwg PLOTTED: 1/23/2026 3:28 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 07-03-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 20'40' GRAPHIC SCALE 1"=20' 0AT&+ &S1 0AT&+ &S¬¬S8%0ITTE' )2R RE9IE: 1 &S TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 226040I''/ET2:N E/E0ENTAR< S&+22/190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANSITE PLAN (RECREATION AREAS) 0AT&+ &S1 F.F.E. (742.79)COASPHALTASPHALTC O N C . W A L K CONC. WALK12" RCP 12" R C P 1 5 " RCPF.F.E. (742.81)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)#190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPT12"PVCEX. 50' GAS ESMTDB 234 PG 359N 39° 04 ' 57" E 724 .91 ' N 33° 57' 54" W 453.18' ASPHALT EX. 6" W/L (CITY OF WINCHESTER)FUEL I S L A N D100' SETBACK (PR INC IPAL USE 165 -401 .07 -A ) TAN K E X R O O F D R A I N S K E T C H E D A P P R O X ( P E R R E C O R D ) EX CURB INLET TOP = 739.89 INV IN = 734.49 INV OUT = 734.19 EX GRATE INLETTOP = 739.95INV IN = 737.65INV OUT = 737.55EX CURB INLETTOP = 742.46INV OUT = 737.96EX CURB INLET TOP = 736.62 INV IN = 732.32 INV OUT = 731.77 12" R C P DUMPSTER PADCONC. RAMPEX GRATE INLETTOP = 740.60INV IN = 736.80INV OUT = 736.70EX GV W/ 6 BOLLARDS EX GV EX GLM EX GLM 12" R C P 100' SETBACK (PRINCIPAL USE 165-401.07-A)15' SETBACK (ACC . USE 165 -401 .07 -C )100' SETBACK (PR INC IPAL USE 165 -401 .07 -A )5' SETBACK (PRKG 165 -202 .01 -D (6 ) )WP1WP1WP120' COW WATERESMTE X . F I R E L I N E - A - 6 " C L - 5 2 D I P E X . 1 " D O M W C T S P E T E X , C O M M , D A T A , A L A R M E X . 3 2 0 L F S A N F M ( P R I V ) 1. 2 5 " S D R - 1 1 H D P E EX. ELEC PANEL & PS CONTROLLER (W/GEN RECEPTACLE) EX. 6' X 6' GRAVEL PAD FOR PORT. GEN 240V / 6,500 WATTGATEEX 6' HT - FENCEEX SAN PS 1 10' COW WATER ESMT (NEW)10' COW WATERESMT (NEW)LP KI T E X P 1, 1 2 7 S F 5' 6" BOL L A R D ( 2 ) 10'x12' STORAGE SHED W/ 11'x13' CONC. SLAB 2'21.6'22'PARENT DROP -OFF / P ICK -UP 3 , 4 2 5 SF - HD ASPHALT RESER V E D A R E A FUTR. F U E L I S L A N D 23'372'R394'RCG-6R (MOD )6' SWLK8 ' SW LK 1'R 28'R8'R RELOCATED LP 11.4 11.3 11.2 11.16" HDPE1 2 " HDPE12" HDPE1, 5 0 0 G A L G R E A S E T R A P 40 L F - 4 " S R D - 2 6 2. 0 % M I N 4" C O 4" S D R - 2 6 - F O O D W A S T E IN V ≤ 7 3 6 . 7 5 ' C O R E D R I L L 4" S D R - 2 6 M A T C H C R O W N I N V O U T = 7 3 5 . 1 8 ' NO PRKG/ FIRE LANE SGN NO PRKG/ FIRE LANE SGNCG-6 10.2 10.1 C O N C . S L A B F O R C O N D E N S I N G U N I T S W / C H A I N L I N K F E N C E & G A T E (A C T U A L S I Z E S U B J E C T T O F I N A L D E S I G N B Y M E P ) 12" RC P C L III 10.0 U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4003.dwg PLOTTED: 1/23/2026 3:28 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 07-03-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 20'40' GRAPHIC SCALE 1"=20' MATCH CS4004 MATCH CS4001  MATCH CS4002SUBMITTED FOR REVIEW 1-23-2026 CS4003 TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANSITE PLAN (KITCHEN & PARENT LOOP) F.F.E. (742.79)COCOCO24" RCP 24" RCP 15" RCP WV WV ASPHALT ASPHALTASPHALTASPHALTC O N C . W A L K C O N C . W A L K CONC. WALK24" RCP18" RCPINV. (734.31)INV. (735.08)18" RCP12" PVCF.F.E. (742.79)PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT 15" RCP12" RCP12"PVC18" RCPASPHALT EX. GAS MAIN (2X)EX. GAS MAIN (2X)SMH EX-B RIM = 738.97 IN = 733.97 OUT = 733.87 3 2 8 . 3 5 ' - 8 " P V C @ 0 . 4 7 % P R I V A T E SMH EX-C RIM = 733.76 IN = 730.26 OUT = 730.16125.54 ' - 8" PVC @ 1 .03%PRIVATE SMH EX-D RIM = 735.87 IN = 728.87 OUT = 728.77±905' TO PUMP STATION MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57" E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'EX. 6" DIP W/L EX. 6" W/M 15' SETBACK (ACC. USE 165-401.07-C) 100' SETBACK (PRINCIPAL USE 165-401.07-A)15' SETBACK (ACC . USE 165 -401 .07 -C )100' SETBACK (PR INC IPAL USE 165 -401 .07 -A ) 5' SETBACK (PRKG 165-202.01-D (6))5' SETBACK (PRKG 165 -202 .01 -D (6 ) ) EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 60' SETBACK (PRINCIPAL USE 165-401.07-A)EX 6" W/L (APPROX)TP#1 (03-22-2025) DOMW - 6" DIP COVER = ±4.4' TP#2 (03-22-2025) DOMW - 6" DIP COVER = ±4.1' EX GRATE TOP = 737.36 INV IN = 733.56 INV OUT = 733.56 EX OUTLET INV OUT = 731.69 PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX TOP = 741.78INV IN = 735.68 (6")INV IN = 734.38 (15")INV OUT = 734.28 (18")EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 198 EX OUTLET INV OUT = 729.61 (SILTED) EX DRY DETENTION POND EX SWM RISER TOP = 733.84 INV IN = 729.14 INV OUT = 729.04 INV IN = 729.08 INV OUT = 728.35 EX CURB INLET TOP = 735.54 INV IN = 730.84 INV OUT = 730.49 EX TOP = 742.33INV IN = 735.83INV IN = 735.58INV OUT = 735.53CANOPYEX GLMEX. 50' GAS ESMTDB 234 PG 35924 ' E P ±85 LF CG-6 CURB 2'REOPEOPEOP EOP 2'R2' R 2'R2' R EOP 5'R 10'R 110'REOPCG-650'R25'R125.54 ' - 8" SDR-35 CORE DRILL EX MH CONNECT 1.5" SAN FM RAVEN COATING REQ.BRICK & GROUT EX INV IN (ROOF DRAINAGE)ARV NO PRKG/ FIRE LANE SGN 752' - 1.5" SAN FM - SDR-11 HDPE (PRIVATE) ARV CUT-IN CONNECTION 8" 45° BEND 8" X 6" REDUCER20' COW WATERESMT (NEW)12.00'5'W/L - A 24+12.93 = W/L - B 30+00 1 - 8" TEE & 3 - 8" GV'S ABANDON IN-PLACE REMOVE EXISTING 6" WATER MAIN REMOVE EX 6" WATER MAIN ABANDON IN PLACE WATERLINE - A 8" CL-52 DIP WATERLINE - A 8" CL-52 DIP WATERLINE - A 8" CL-52 DIP WATERLINE - B8" CL-52 DIP21+00 22+00 2 3 + 0 0 24+00 25+00 26+00 2 7 + 0 030+0030+7020' COW WATERESMT (TOTAL)10' COW WATERESMT (NEW)ARV W/L - B 22+45.32 1 - 8" TEE & 2 - 8" GV'S STUB 1 - 8" CL52 DIP PIPE JOINT 1 - TAPPED CAP FLUSH ASSM PLUG LINE TO BE ABANDONED PLUG LINE TO BE ABANDONED 9' OF EX. 6" W/L TO BE REPLACED W/ 8" W/L 10' COW WATER ESMT (NEW) 20' COW WATER ESMT. (NEW) 10.00'10.00'W A T E R L I N E - A 8" C L - 5 2 D I P PORTION OF EX COW ESMT TO BE VACATED U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4004.dwg PLOTTED: 1/23/2026 3:28 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 07-03-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 20'40' GRAPHIC SCALE 1"=20' ¬MAT&+ &SMAT&+ &SMAT&+ &SSU%M,TT(' )25 5(9,(:  &S TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604M,''L(T2:N (L(M(NTA5< S&+22L190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANSITE PLAN (BUS LOOP & ENTRANCE) MAT&+ &S TP#4C (06-07-2025) DOMW - 8" DIP COVER = ±4.2' TP#4B (06-07-2025) DOMW - 8" DIP COVER = ±4.5' EX. 8" DIP W/L 48.58' - 24" RCP PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 CITY OF WINCHESTER SMH EX-E RIM = 732.80 IN = 725.70 OUT = 725.60 INV = 728.80' INV = 727.83' EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 1985'WATER MAIN REPLACEMENT NOTES 1.THE APPROXIMATED CONNECTION STATION (19+17.36) IS ESTIMATED BASED ON FIELD INVESTIGATION AND TEST PIT LOCATION (TP#4C). AVAILABLE RECORD PLANS / AS-BUILT INFORMATION IS NOT CONSISTENT WITH FIELD CONDITIONS. 2.THE EXACT LOCATION OF THE PROPOSED CUT-IN OF WATERLINE "A" (AT THE EXISTING 8"X6" REDUCER) SHALL BE DETERMINED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. BEST AVAILABLE INFORMATION SUGGESTS IT'S BETWEEN STA. 19+17.36 AND STA. 22+45.32 (EXISTING 6" TEE) REMOVE EXISTING 6" WATER MIAN WATERLINE - A 8" CL-52 DIP 18+9719+00 20+0010' COW WATERESMT (NEW)CUT IN CONNECTION 2 - 45° HORZ BENDS 1 - 8" GV TP#4C (06-07-2025) DOMW - 8" DIP COVER = ±4.2' TP#4B (06-07-2025) DOMW - 8" DIP COVER = ±4.5' EX. 8" DIP W/L 48.58' - 24" RCP PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 CITY OF WINCHESTER SMH EX-E RIM = 732.80 IN = 725.70 OUT = 725.60 INV = 728.80' INV = 727.83' EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 198 U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4005.dwg PLOTTED: 1/23/2026 3:29 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 07-03-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 20'40' GRAPHIC SCALE 1"=20' MAT&+ &SSU%M,TT(' )25 5(9,(:  &S TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604M,''L(T2:N (L(M(NTA5< S&+22L190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANSITE PLAN (MUSTANG LN) WIDENING ±1,680 SF - HD ASPHALT PARKING AREA #1±3,860 SF - SD ASPHPARKING AREA #2 SD ASPH - ±2,570 SF BUS PARKING HD ASPH - ±3,840 SF PARKING AREA #3 SD ASPH - ±1,370 SF EMERGENCY ACCESS ROADGRAVELEMERGENCY ACCESS ROADGRAVELPARENT DROP -OFF / P ICK -UP3,425 SF - HD ASPHALT ±5,24 0 S F HD A S P H A L TBUSONLY BUSONLYEX B-BALL COURT(ASPHALT)#190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPT MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57 " E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'S 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1N 33° 57' 54" W 453.18'INTERSTATE 81(LIM ITED ACCESS ROW) CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 FUEL I S L A N D TP#4C (06-07-2025) DOMW - 8" DIP COVER = ±4.2' PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT BRIAN J. HESTER, TRUSTEE EX DRY DETENTION POND EX BIO-RET AWP1FHWP1WP1WP1WP1WP1WP1WP1WP1WP1WP1 EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1 LP KI T E X P 1, 1 2 7 S F GYM N A S I U M LFL = 7 2 8 . 8 0 'CLASSROOMS( 2 -STORY )LFL = 728 . 8 0 ' GRASS R E C A R E A ±30,800 S F B L D G E X P A N S I O N 21 , 8 7 9 S F 10'x12' STORAGE SHED W/ 11'x13' CONC. SLAB RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A ASPH A L T PLAY A R E A 4,500 S F M F L = 7 4 2 . 8 0 'PARENT DROP -OFF / P ICK -UP3,425 SF - HD ASPHALT RESERVED AREA FUTR. FUEL ISLAND 6' SW L K RET. WALL (30 LF)6' SWLK ±5,24 0 S F HD A S P H A L T TRASH ENCLOSURE ±210 SF - HD CONC (HEAVY DUTY) ASPHALT PAVEMENT NTS 1 1 2" SURFACE COURSE (SM 12.5A) 3" BASE COURSE (BM25) COMPACTED SUBGRADE 8" DENSE GRADED STONE (21B) CONCRETE SIDEWALK NTS 4" CONCRETE 4" DENSE GRADED STONE (21B) COMPACTED SUBGRADE (STANDARD DUTY) ASPHALT PAVEMENT NTS 1 1 2" SURFACE COURSE (SM 12.5A) 2" IM 19.0 COMPACTED SUBGRADE 6" DENSE GRADED STONE (21B) PAVEMENT NOTES: 1.PARKING LOT DRIVE AISLES AND BUS PARKING SPACES SHALL BE HEAVY DUTY ASPHALT PAVING. 2.STANDARD AND HANDICAP PARKING SHALL BE STANDARD DUTY ASPHALT PAVING. 3.ALL SIDEWALKS, REGARDLESS OF WIDTH SHALL BE CONCRETE. 4.DUMPSTER AREA SHALL BE HEAVY DUTY CONCRETE. (HEAVY DUTY) CONCRETE DUMPSTER PAD NTS 7" - 4,000 PSI CONCRETE 8" DENSE GRADED STONE (21B) COMPACTED SUBGRADE 6" X 6" W2.9 W.W.F. (PLAY AREA) ASPHALT PAVEMENT NTS 1 1 2" SURFACE COURSE (SM 12.5A) 2" IM 19.0 COMPACTED SUBGRADE 6" DENSE GRADED STONE (21B) 1 2":1' 8' 12" 21B COMPACTED SUBGRADE 8' 16' 20' 2'2' 1":1' 1":1' UD-4 NOTES: 1. 4" MINIMUM, PROVIDED ATTAINING 4" OF AGGREGATE ON TOP OF PIPE 2. OUTLET PIPES ARE TO BE INSTALLED ON 2% MIN. (3% DESIRABLE) GRADE AND LOCATED EVERY 350' MAXIMUM OR AS NOTED ON PLANS. GEOTEXTILE DRAINAGE FABRIC (OVERLAP 1' AT TOP) 4" PIPE OUTLET PIPE WITH "RODENT PROOF" COVER/GRATE .25'#57 AGGREGATE, #8 AGGREGATE OR CRUSHED GLASS MEETING #8 GRADATION REQUIREMENT EMERGENCY ACCESS ROAD NTS U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4006.dwg PLOTTED: 1/23/2026 3:29 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 40'80' GRAPHIC SCALE 1"=40'SU%MITTE' )2R RE9IE: 1 &S TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MI''LET2:N ELEMENTAR< S&+22L190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANPAVING PLAN 736 735 7347337327307297287277267257247237227217207197 1 9 7207 2 1 72 27427417 3 3 7 3 2 7317307207177177 1 8 7187197217227237247157207127137147167177187197217227237247357347 3 0 7 2 9 7 3 1 728 728 728740 7377 3 8 7 3 9 730728729731732733735740734736737738739741725 725 725 721 722 723 724 724 724 726 727730 735 740 732733 734 736 737 738 739 741 74 2 7327 2 8 7287 3 0 7 2 9 7 3 1 7 3 2 7 3 3 7 3 4 725730723723724726727728729731732733730727728729731732733727 727728 728 729 728 72572272372472672772 5 72 3 7 2 4 72 4 72 6 72 7 735 730 73 5 73 1 73 2 73 3 73 4 736 737 73 8 7 3 9 725 730 722 723 724 726 727 728 729 731 732 733 734 72 5 730 73 5 74 0 723 72 4 72 6 72 7 728 729 73 1 73 2 73 3 73 4 7 3 6 73 7 73 8 739 725 730 735 723 724 726 727 728 729 731 732 733 734 720725725721722723723724724725723724726727734TW=734.00 BW=728.80 2817 HP 2773 EG 2820 TOP 28 48 31 50 29 25 29 15 28 48 EC 28 10 EP 2764 EP 28 10 EP 28 20 EP 2708 OLR 2719 EG 27 54 EG 27 84 EG 2748 EG 28 60 EC 28 48 EC 28 15 EP 27 87 EP 27 20 26 66 27 75 28 10 29 00 EG 27 48 2535 INV 2796 EG 2762 OLR 2779 EG 2757 EP 3040 EP 2788 EP 2788 EP 2770 EP 2740 FC 2778 EP 2760 FC 2780 EP 2718 EG 3101 EP 2737 EG 3102 EP 2778 EP 3070 EP 3925 EP 3574 EP 3832 EP 3574 EP 2.0%9.3%2.0%PRE- T R E A T M E N T F O R E B A Y BIORETENTION B SEE DETAILS & COMPS, SH CS9502 6" SOLID WALL UNDER DRAIN 1 - 6" OBSERVATION WELL (SEE DETAIL SH. CS9502) 6" PERFORATED UNDER DRAIN (TYP) OVERFLOW WEIR SEE "TYPICAL BIO-RETENTION OVERFLOW WEIR DETAIL" SH. CS9502 1 - 6" CLEANOUT, TYP (SEE DET SH. CS9502) TOP BE R M = 7 2 5 . 0 0 ' SWM DETENTION POND (FOR QUANTITY ONLY) IMPERMEABLE LINER LIMITS TOP OF BERM = 725.00 20' WIDE x 9' BREADTH VEGETATED WEIR ELEV = 724.00 20' WIDE x 9' BREADTH VEGETATED WEIR ELEV = 724.00 BIORE TEN T ION FAC I L I T Y B 2756 EG 2721 EG 2679 EG 2668 EG 3117 OLR 2.0% 2.0%10.0%2660 2819 CL 2809 CL 2797 OLR 2795 CL 2740 CL 4.2% 2776 CL 3123 CL 9.3% 1.2% 0.6% 1.9% 2757 CL 2775 LP 2783 EP2.0%0.7% 2808 HP 2880 2880 2880 EC 2880 2880 3143 33263267 3374 4280 3008 2880 2880 2880 28 60 EC2.0%725 730 721722723724 726727728729 725 730 721 722 723 724 726 727 728 729 731 7257217227237247267272796 EG 2756 EG2776 CL 2796 EG 2756 EG2776 CL 2880 2830 OLR 2830 OLR 2820 EC 2820 EC 2870 EC2875 EC 2812 EC 2812 EC 3090 TOP 2685 TOP 2775 TOP 2775 TOP 2725 TOP 2814 TOP 2685 TOP 2800 2830 2880 EC 0.9% 2880 2880 2870 EC 2870 EC 2880 EC 2880 EC 28 72 EC 28 59 EC 28 59 EC 28 70 EC 28 80 EC0.4%4.0%1.4%1.2% 2744 EG 2771 EP 2714 EG 2751 EG 2725 EG 2725 EG 2753 EG 2782 FC 2766 FC 2786 EP 2771 FC 2788 FC 3984 3180 2748 2731 2748 2736 2782 FC0.9%3:1 SLOPE4:1 SLOPE3:1 SLOP E3:1 SLOPE3:1 SLOPE2735 EG 2715 EG 2730 EG 2715 EG 2710 EG 2690 EG 0. 4 % 2705 HP2635 INV 4046 EP 4086 52 EP 4086 SEE "TYPICAL FOREBAY OUTFALL DETAIL" SH. CS9502 BOTTOM OF GABION WEIR = 723.00 TOP OF GABION WEIR = 724.00 0.7% 1. 7 % 2. 0 % 7 2 8 726726727 727 7 2 7 7277277277402680 HP SEE "SWM FACILITY HGL SECTION", SH CS4101 725 7257257 2 3 723 724724 725 725 721 722 723 723 724 724 2300 INV TOP BERM = 725.00'2300 INV 2400 WEIR 2400 WEIR 2400 WEIR 2400 WEIR 2400 WEIR 2300 2347 2086 TOP BERM = 725.00'PR SWM RISER SEE DETAILS, SH. CS9501 COF.F.E. (742.78)SCOCOC O N C . W A L KCONC. WALKCONC. WALK6" PVC12" PVCF.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)LIM ITED ACCESS FENCE15" RCP18" RCPS 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 'INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT EX TOP = 741.78INV IN = 735.68 (6")INV IN = 734.38 (15")INV OUT = 734.28 (18")INV = 710.67' INV = 714.88' 121.7 8 ' - 3 6 " C M P @ 3 . 4 6 % GYM N A S I U M LFL = 7 2 8 . 8 0 'CLASSROOMS( 2 -STORY )LFL = 7 28 . 8 0 ' B L D G E X P A N S I O N 21 , 8 7 9 S F ASPH A L T PLAY A R E A 4,500 S F M F L = 7 4 2 . 8 0 ' 8' S W L K 6' SW L K8' SWLK23.5'RAMPRET. WALL ( 3 0 LF )6' SWLK CG- 6 CG-6 TRAS H E N C L O S U R E ±210 S F - H D C O N C CG-1 2 A CG-12 A6' SWLK 6 ' SWLK 12.00' 6.00' 6.00'CANOPYCANO P Y RI S E R R M L F LMASONRY WALLREF ARCHITECTURE6 6 . 2 1 ' - 6 " S D R - 2 6 38.28' - 6" SDR-26 45.56' - 6" SDR-26 PR. S A N P U M P S T A . (PRIV A T E ) PR. SAN LAT - 4" SDR-26 ASSUME 3.0' BELOW LFL PR. SAN LAT - 4" SDR-26 ASSUME 3.0' BELOW LFL BRICK & GROUT EX INV OUTBRICK & GROUT EX INV IN (ROOF DRAINAGE) CORE-DRILL FOR NEW 18" HDPE INV OUT2.4 6.1A 6.1 2.2 4.1 1.2 4.4 2.1 1.1 4.56" H D P E 12" H D P E24" HDPE18" HDPE 2 4 " H D P E8" HDPE18" HDPE18" HD P E 2 4 " H D P E 15" HDPECO1A CO1 CO2 CO3 PS2 1 0 ' ELEC ESMT (REC ) 2.3 3.1 3.2 2.5 (EX1.2) 4.3 4.2 5.1 3.2A 12" HDPE12" H D P E 15" HD P E 15" HDPE24" H D P E 12" HDPE TRAPEZOIDAL CHANNEL 2'(W) BOTTOM x 12'(L) CLIA RIPRAP W/ FILTER FABRIC CG-6EOP752' - 1 . 5 " S A N F M - S D R - 1 1 H D P E (PRI V A T E ) BASK E T B A L L G O A L (1 OF 2)RAMPS 12 :1 MAXW / HR - 1 HAND RA ILSWFDC COMBINATION VAULT 1 - 3" DOMW METER (COW) 1 - 6" FIRE METER (COW) REMOVE EX FH & REPLACE FURNISH TO COW PR. FH ASSM. 2 1 2 " DOMW SERV. (REF PLUMBING PLANS) 6" FIRE SERV. (REF PLUMBING PLANS) FDC WATER LI N E - C 8" CL- 5 2 DI P 20' COW WATER ESMT. (NEW) 8" X 8" TEE 8" GV 8" X 6" RED 8" GV 8" X 6" RED 4" GV 8" X 4" TEE 8" X 6" RED 8" GV W A T E R L I N E - A 8" C L - 5 2 D I P LOD LOD LOD COF.F.E. (742.78)SCOCOC O N C . W A L KCONC. WALKCONC. WALK6" PVC12" PVCF.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)LIM ITED ACCESS FENCE15" RCP18" RCPS 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 'INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT EX TOP = 741.78INV IN = 735.68 (6")INV IN = 734.38 (15")INV OUT = 734.28 (18")INV = 710.67' INV = 714.88' 121.7 8 ' - 3 6 " C M P @ 3 . 4 6 %10+001 1 + 0 0 12+00SWMF SWMF SWM FACILITY HGL SECTION HORZ: 1" = 50' | VERT: 1" = 5' 715 720 725 730 735 715 720 725 730 735 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 SEE "TYP FOREBAY OUTFALL DETAIL" SH CS9502 100YR WSE = 724.52' EX GRADE PR GRADE (3:1 SLOPE) FOREBAY BIORETENTIONDRY DETENTION VEGETATED WEIR = 724.00' TOP GABION WEIR = 723.50' BOTTOM GABION WEIR = 723.00' TOP OF ADJACENT BERM = 725.00'TOP OF ADJACENT BERM = 725.00' SEE "TYP BIORETENTION OVERFLOW WEIR DETAIL" SH CS9502 OVERFLOW WEIR = 724.00' 100YR WSE = 724.51' 100YR WSE = 723.40'PR GRADE 1YR WSE = 724.02'1YR WSE = 724.02' 1YR WSE = 720.64'U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4101.dwg PLOTTED: 1/23/2026 3:30 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 20'40' GRAPHIC SCALE 1"=20'MATCH CS1MATCH CS1¬S8%MITTE' FOR RE9IEW 1 CS11 TOTAL SHEETS 42    1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MI''LETOWN ELEMENTARY SCHOOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANGRADING PLAN (BLDG. EXPANSION) MATCH CS1NORTH00 50'100' GRAPHIC SCALE 1"=50' 72 2 72 3 7 2 4 72572 6 727 729 728 729724 725 726 727 728 729730 73173373874074374274174073973873 773673 5734 742 742 7247387427 3 4 733 736 737739739738 7257307237237247267277287297317327337257307267277287297317 3 8 7 3 7 729 730 728 729 731 73 2 7 3 3 73438 16 EP 3794 EP 3639 EG 3599 EG 3669 EG 3709 EG 3426 EG 34 00 31 60 31 50 28 10 EP 27 20 29 00 EG 27 48 1.5%1.0%1.0%1.8%1.8 % 3080 3190 3080 3290 3290 34002.0%3350 HP 2.0%3900 HP 3127 3121 3:1 SLOP E 3:1 S L O P E4:1 SLOPE3 : 1 S L O P E730 73 5 7297317 3 2 7 3 3 73 4 73 6 7307287297317327257307357267277287297317327337347367377387397257307267277287297 3 1 7317 3 2 7327 3 3 733EX B-BALL COURT(ASPHALT)C O N C . W A L K CONC. WALK CONC. WALKCONC. WALKF.F.E. (742.81)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)#190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPT S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1 N 33° 57' 54" W 453.18' CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 100' SETBACK (PRINCIPAL USE 165-401.07-A)DSINTERSTATE 81(LIM ITED ACCESS ROW) EX BIO-RET AEX GRATE INLETTOP = 739.95INV IN = 737.65INV OUT = 737.55EX CURB INLETTOP = 742.46INV OUT = 737.9612" R C P 100' SETBACK(PRINC IPAL USE 165-401 .07-A) 100' SETBACK (PRINCIPAL USE 165-401.07-A)WP1FHWP1 WP1 WP1 WP1 WP1WP1WP1WP1WP1WP1 20' EMERGENCY ACCESS RD GRAVEL20'EX. 5' CO N C S / W RAMPRAMPRAMP20' COW WATERESMTE X . F I R E L I N E - A - 6 " C L - 5 2 D I P E X . 1 " D O M W C T S P E T E X , C O M M , D A T A , A L A R M EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. E X . 3 2 0 L F S A N F M ( P R I V ) 1. 2 5 " S D R - 1 1 H D P E EX. ELEC PANEL & PS CONTROLLER (W/GEN RECEPTACLE) EX. 6' X 6' GRAVEL PAD FOR PORT. GEN 240V / 6,500 WATT EX 6' HT - FENCEGATETEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) 6' HT - FENCEEX 6' HT - FENCEEX SAN PS 1 GRASS R E C A R E A ±30,800 S F RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE ARAMP 10' UGND UTIL ESMT 1 0 ' ELEC ESMT (REC )RAMP10'RAMPS 12 :1 MAXW / HR - 1 HAND RA ILS LOD LOD LOD EX B-BALL COURT(ASPHALT)C O N C . W A L K CONC. WALK CONC. WALKCONC. WALKF.F.E. (742.81)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)#190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPT S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1 N 33° 57' 54" W 453.18' CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 100' SETBACK (PRINCIPAL USE 165-401.07-A)DSINTERSTATE 81(LIM ITED ACCESS ROW) EX BIO-RET AEX GRATE INLETTOP = 739.95INV IN = 737.65INV OUT = 737.55EX CURB INLETTOP = 742.46INV OUT = 737.9612" R C P 100' SETBACK(PRINC IPAL USE 165-401 .07-A) 100' SETBACK (PRINCIPAL USE 165-401.07-A)WP1FHWP1 WP1 WP1 WP1 WP1WP1WP1WP1WP1WP1 20' EMERGENCY ACCESS RD GRAVEL20'EX. 5' CO N C S / W RAMPRAMPRAMP20' COW WATERESMTE X . F I R E L I N E - A - 6 " C L - 5 2 D I P E X . 1 " D O M W C T S P E T E X , C O M M , D A T A , A L A R M EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. E X . 3 2 0 L F S A N F M ( P R I V ) 1. 2 5 " S D R - 1 1 H D P E EX. ELEC PANEL & PS CONTROLLER (W/GEN RECEPTACLE) EX. 6' X 6' GRAVEL PAD FOR PORT. GEN 240V / 6,500 WATT EX 6' HT - FENCEGATETEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) 6' HT - FENCEEX 6' HT - FENCEEX SAN PS 1 U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4102.dwg PLOTTED: 1/23/2026 3:30 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 20'40' GRAPHIC SCALE 1"=20' 0AT&+ &S11 0AT&+ &S1¬¬S8%0ITTE' )2R RE9IE: 1 &S1 TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 226040I''/ET2:N E/E0ENTAR< S&+22/190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANGRADING PLAN (RECREATION AREAS) 0AT&+ &S1 74 5 744 743742741740 739738737736 735734733738739740733734735736737 739 738737 740737738 73974074274174374474 4 743 740 743 7427417 4 0740739738 7417 4 2 742728742 742 743 4250 OLR 4235 TOP 4300 HP 4178 EP 4189 EP 4341 EP0.7% 4323 CL 4305 EP 2.0%1.3%2.3%4175 TOP 4351 TOP 4345 FC 4336 FC 4250 EC 4363 EC 4312 EC 4305 EC R A I S E G R A D E A L O N G F A C E O F E X B L D G . , A S N E C E S S A R Y T O E N S U R E P O S I T I V E D R A I N A G E A W A Y ( M A X = 7 4 2 . 7 5 ) 4250 HP 4167 EP 4203 EP 2.0% 4228 EC 4212 TC 4175 TC 4188 TC 4330 EP742743 7447447437437 4 3 7437437437424411 EC R A I S E G R A D E A L O N G F A C E O F E X B L D G . , A S N E C E S S A R Y T O E N S U R E P O S I T I V E D R A I N A G E A W A Y ( M A X = 7 4 2 . 7 5 )F.F.E. (742.79)COASPHALTASPHALTC O N C . W A L K CONC. WALK12" RCP 12" R C P 1 5 " RCPF.F.E. (742.81)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)#190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPT12"PVCEX. 50' GAS ESMTDB 234 PG 359N 39° 04 ' 57 " E 724 .91 ' N 33° 57' 54" W 453.18' ASPHALT EX. 6" W/L (CITY OF WINCHESTER)FUEL I S L A N D100' SETBACK (PR INC IPAL USE 165 -401 .07 -A ) TAN K E X R O O F D R A I N S K E T C H E D A P P R O X ( P E R R E C O R D ) EX CURB INLET TOP = 739.89 INV IN = 734.49 INV OUT = 734.19 EX GRATE INLETTOP = 739.95INV IN = 737.65INV OUT = 737.55EX CURB INLETTOP = 742.46INV OUT = 737.96EX CURB INLET TOP = 736.62 INV IN = 732.32 INV OUT = 731.77 12" R C P DUMPSTER PADCONC. RAMPEX GRATE INLETTOP = 740.60INV IN = 736.80INV OUT = 736.70EX GV W/ 6 BOLLARDS EX GV EX GLM EX GLM 12" R C P 100' SETBACK (PRINCIPAL USE 165-401.07-A)15' SETBACK (ACC . USE 165 -401 .07 -C )100' SETBACK (PR INC IPAL USE 165 -401 .07 -A )5' SETBACK (PRKG 165 -202 .01 -D (6 ) )WP1WP1WP120' COW WATERESMTE X . F I R E L I N E - A - 6 " C L - 5 2 D I P E X . 1 " D O M W C T S P E T E X , C O M M , D A T A , A L A R M E X . 3 2 0 L F S A N F M ( P R I V ) 1. 2 5 " S D R - 1 1 H D P E EX. ELEC PANEL & PS CONTROLLER (W/GEN RECEPTACLE) EX. 6' X 6' GRAVEL PAD FOR PORT. GEN 240V / 6,500 WATTGATEEX 6' HT - FENCEEX SAN PS 1 LP KI T E X P 1, 1 2 7 S F 10'x12' STORAGE SHED W/ 11'x13' CONC. SLAB RESER V E D A R E A FUTR. F U E L I S L A N D CG-6R (MOD )6' SWLK8 ' SW LK RELOCATED LP 11.4 11.3 11.2 11.16" HDPE1 2 " HDPE12" HDPE1, 5 0 0 G A L G R E A S E T R A P 40 L F - 4 " S R D - 2 6 2. 0 % M I N 4" C O 4" S D R - 2 6 - F O O D W A S T E IN V ≤ 7 3 6 . 7 5 ' C O R E D R I L L 4" S D R - 2 6 M A T C H C R O W N I N V O U T = 7 3 5 . 1 8 'CG-6 10.2 10.1 C O N C . S L A B F O R C O N D E N S I N G U N I T S W / C H A I N L I N K F E N C E & G A T E (A C T U A L S I Z E S U B J E C T T O F I N A L D E S I G N B Y M E P ) 12" RC P C L III 10.0 10' COW WATER ESMT (NEW)10' COW WATERESMT (NEW)LOD LOD F.F.E. (742.79)COASPHALTASPHALTC O N C . W A L K CONC. WALK12" RCP 12" R C P 1 5 " RCPF.F.E. (742.81)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)#190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPT12"PVCEX. 50' GAS ESMTDB 234 PG 359N 39° 04 ' 57 " E 724 .91 ' N 33° 57' 54" W 453.18' ASPHALT EX. 6" W/L (CITY OF WINCHESTER)FUEL I S L A N D100' SETBACK (PR INC IPAL USE 165 -401 .07 -A ) TAN K E X R O O F D R A I N S K E T C H E D A P P R O X ( P E R R E C O R D ) EX CURB INLET TOP = 739.89 INV IN = 734.49 INV OUT = 734.19 EX GRATE INLETTOP = 739.95INV IN = 737.65INV OUT = 737.55EX CURB INLETTOP = 742.46INV OUT = 737.96EX CURB INLET TOP = 736.62 INV IN = 732.32 INV OUT = 731.77 12" R C P DUMPSTER PADCONC. RAMPEX GRATE INLETTOP = 740.60INV IN = 736.80INV OUT = 736.70EX GV W/ 6 BOLLARDS EX GV EX GLM EX GLM 12" R C P 100' SETBACK (PRINCIPAL USE 165-401.07-A)15' SETBACK (ACC . USE 165 -401 .07 -C )100' SETBACK (PR INC IPAL USE 165 -401 .07 -A )5' SETBACK (PRKG 165 -202 .01 -D (6 ) )WP1WP1WP120' COW WATERESMTE X . F I R E L I N E - A - 6 " C L - 5 2 D I P E X . 1 " D O M W C T S P E T E X , C O M M , D A T A , A L A R M E X . 3 2 0 L F S A N F M ( P R I V ) 1. 2 5 " S D R - 1 1 H D P E EX. ELEC PANEL & PS CONTROLLER (W/GEN RECEPTACLE) EX. 6' X 6' GRAVEL PAD FOR PORT. GEN 240V / 6,500 WATTGATEEX 6' HT - FENCEEX SAN PS 1 U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4103.dwg PLOTTED: 1/23/2026 3:31 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 20'40' GRAPHIC SCALE 1"=20' MATCH CS4104   MATCH CS4102SUBMITTED FOR REVIEW 1-23-2026 CS4103 TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANGRADING PLAN (KITCHEN & PARENT LOOP)   730 735 7317 3 2 73373473 5 7 3 6 7377367 3 7 73 8 739740 741 742 740 73973 8737 736 73774 2 7 4 1 74 0 739 738 74 1 7 4 0739738 738737736737741742741 7 4 2 74 1 7 4 073973 8 73 7 742735 730728727739 740 73973873973 7 73 6 73 4 735 732731733741740 74 1 735 736 736 736 737 7 3 8 739 7 4 0 736 737 73 8 73974 0 739 7403972 EP4070 EP 4096 EP 4058 EP 4008 EP 4109 EP 4103 EP 4108 EP 4160 EP 4199 EP 4174 EP 4079 EP 3900 EP 4001 EP 4055 EP 4065 EP 0.9%1.9%1.9%2.0%2.0%1.4%1.7% 4046 EP 4052 EP 4066 EP 4086 0.7% 1. 7 % 2. 0 % 4106 740741740741741DRY SWALE A 50 ' LONG X 2' WIDE SURFACE AREA = 100 ft2 (SEE DET SH. CS9503) 1 - 12" CHECK DAM (SEE DET SH. CS9503) BOTTOM OF WEIR = 735.10 TOP OF WEIR = 736.10 3610 3510 2.0%F.F.E. (742.79)COCOCO24" RCP 24" RCP 15" RCP WV WV ASPHALT ASPHALTASPHALTASPHALTC O N C . W A L K C O N C . W A L K CONC. WALK24" RCP18" RCPINV. (734.31)INV. (735.08)18" RCP12" PVCF.F.E. (742.79)PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT 15" RCP12" RCP12"PVC18" RCPASPHALT EX. GAS MAIN (2X)EX. GAS MAIN (2X)SMH EX-B RIM = 738.97 IN = 733.97 OUT = 733.87 3 2 8 . 3 5 ' - 8 " P V C @ 0 . 4 7 % P R I V A T E SMH EX-C RIM = 733.76 IN = 730.26 OUT = 730.16125.54 ' - 8" PVC @ 1 .03%PRIVATE SMH EX-D RIM = 735.87 IN = 728.87 OUT = 728.77±905' TO PUMP STATION MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57" E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'EX. 6" DIP W/L EX. 6" W/M EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 TP#1 (03-22-2025) DOMW - 6" DIP COVER = ±4.4' TP#2 (03-22-2025) DOMW - 6" DIP COVER = ±4.1' EX GRATE TOP = 737.36 INV IN = 733.56 INV OUT = 733.56 EX OUTLET INV OUT = 731.69 PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX TOP = 741.78INV IN = 735.68 (6")INV IN = 734.38 (15")INV OUT = 734.28 (18")EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 198 EX OUTLET INV OUT = 729.61 (SILTED) EX DRY DETENTION POND EX SWM RISER TOP = 733.84 INV IN = 729.14 INV OUT = 729.04 INV IN = 729.08 INV OUT = 728.35 EX CURB INLET TOP = 735.54 INV IN = 730.84 INV OUT = 730.49 EX TOP = 742.33INV IN = 735.83INV IN = 735.58INV OUT = 735.53CANOPYEX GLMEX. 50' GAS ESMTDB 234 PG 359±85 LF CG-6 CURB EOPEOPEOP EOP EOP EOPCG-6125.54 ' - 8" SDR-35 CORE DRILL EX MH CONNECT 1.5" SAN FM RAVEN COATING REQ.BRICK & GROUT EX INV IN (ROOF DRAINAGE)ARV 752' - 1.5" SAN FM - SDR-11 HDPE (PRIVATE) LOD LOD LOD LOD LOD F.F.E. (742.79)COCOCO24" RCP 24" RCP 15" RCP WV WV ASPHALT ASPHALTASPHALTASPHALTC O N C . W A L K C O N C . W A L K CONC. WALK24" RCP18" RCPINV. (734.31)INV. (735.08)18" RCP12" PVCF.F.E. (742.79)PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT 15" RCP12" RCP12"PVC18" RCPASPHALT EX. GAS MAIN (2X)EX. GAS MAIN (2X)SMH EX-B RIM = 738.97 IN = 733.97 OUT = 733.87 3 2 8 . 3 5 ' - 8 " P V C @ 0 . 4 7 % P R I V A T E SMH EX-C RIM = 733.76 IN = 730.26 OUT = 730.16125.54 ' - 8" PVC @ 1 .03%PRIVATE SMH EX-D RIM = 735.87 IN = 728.87 OUT = 728.77±905' TO PUMP STATION MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57" E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'EX. 6" DIP W/L EX. 6" W/M EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 TP#1 (03-22-2025) DOMW - 6" DIP COVER = ±4.4' TP#2 (03-22-2025) DOMW - 6" DIP COVER = ±4.1' EX GRATE TOP = 737.36 INV IN = 733.56 INV OUT = 733.56 EX OUTLET INV OUT = 731.69 PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX TOP = 741.78INV IN = 735.68 (6")INV IN = 734.38 (15")INV OUT = 734.28 (18")EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 198 EX OUTLET INV OUT = 729.61 (SILTED) EX DRY DETENTION POND EX SWM RISER TOP = 733.84 INV IN = 729.14 INV OUT = 729.04 INV IN = 729.08 INV OUT = 728.35 EX CURB INLET TOP = 735.54 INV IN = 730.84 INV OUT = 730.49 EX TOP = 742.33INV IN = 735.83INV IN = 735.58INV OUT = 735.53CANOPYEX GLMEX. 50' GAS ESMTDB 234 PG 359ARV 20' COW WATERESMT (NEW)12.00'5'21+00 22+00 2 3 + 0 0 24+00 25+00 26+00 2 7 + 0 030+0030+7020' COW WATERESMT (TOTAL)10' COW WATERESMT (NEW)10' COW WATER ESMT (NEW) 20' COW WATER ESMT. (NEW) 10.00'10.00'U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4104.dwg PLOTTED: 1/23/2026 3:32 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 20'40' GRAPHIC SCALE 1"=20'MAT&+ &SMAT&+ &SMAT&+ &SSU%M,TT(' )25 5(9,(:  &S TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604M,''L(T2:N (L(M(NTA5< S&+22L190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANGRADING PLAN (BUS LOOP & ENTRANCE) MAT&+ &SMAT&+ &S 735 733 73 4 72973073173 0 7 3 1 731 732 732 731 730 731 732 733 73 4 73 5 73 6 73 7 73 8 739 732 733 73 4 733TP#4C (06-07-2025) DOMW - 8" DIP COVER = ±4.2' TP#4B (06-07-2025) DOMW - 8" DIP COVER = ±4.5' EX. 8" DIP W/L 48.58' - 24" RCP PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 CITY OF WINCHESTER SMH EX-E RIM = 732.80 IN = 725.70 OUT = 725.60 INV = 728.80' INV = 727.83' EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 1985'WATER MAIN REPLACEMENT NOTES 1.THE APPROXIMATED CONNECTION STATION (19+17.36) IS ESTIMATED BASED ON FIELD INVESTIGATION AND TEST PIT LOCATION (TP#4C). AVAILABLE RECORD PLANS / AS-BUILT INFORMATION IS NOT CONSISTENT WITH FIELD CONDITIONS. 2.THE EXACT LOCATION OF THE PROPOSED CUT-IN OF WATERLINE "A" (AT THE EXISTING 8"X6" REDUCER) SHALL BE DETERMINED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. BEST AVAILABLE INFORMATION SUGGESTS IT'S BETWEEN STA. 19+17.36 AND STA. 22+45.32 (EXISTING 6" TEE) REMOVE EXISTING 6" WATER MIAN WATERLINE - A 8" CL-52 DIP10' COW WATERESMT (NEW)CUT IN CONNECTION 2 - 45° HORZ BENDS 1 - 8" GV TP#4C (06-07-2025) DOMW - 8" DIP COVER = ±4.2' TP#4B (06-07-2025) DOMW - 8" DIP COVER = ±4.5' EX. 8" DIP W/L 48.58' - 24" RCP PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 CITY OF WINCHESTER SMH EX-E RIM = 732.80 IN = 725.70 OUT = 725.60 INV = 728.80' INV = 727.83' EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 198 U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4105.dwg PLOTTED: 1/23/2026 3:32 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 20'40' GRAPHIC SCALE 1"=20' ¬¬¬¬MAT&+ &SSU%M,TT(' )25 5(9,(:  &S TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604M,''L(T2:N (L(M(NTA5< S&+22L190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANGRADING PLAN (MUSTANG LN) ¬ 12" ground clearance 3" max. 1" min. height of brace shall be in accordance with manufacturer's specifications 12" 10' (max) gate post 12" one tension wire clip each line pole (No. 6 gauge min.) 3/8" min. round rod with turnbuckle end corner or 6'-0" 3'-6" concrete footing No. 11 gauge & 1" beveled galvanized steel band with bolt and nut 1-5/8" SS-15 top rail 2" OD SS-40 line post 2-1/2" mesh, 9 gauge galvanized wire fabric tension wire no. 7 gauge galvanized coil spring wire stretched out typical spacing between all line posts Line brace - shall be used when vertical alignment changes 15° (max. spacing 500') - shall be used at fence end (as shown above) and gate locations Corner brace - shall be used when horizontal alignment changes 15° or more - shall be used as detailed above with bracing in both directions 2-1/2"OD SS-40 terminal post 3'-0" 10' (max) finished grade All posts, rails, tension wires, turnbuckles and hardware shall be black vinyl coated or as otherwise approved by owner. concrete footing 12"12" 3/8" minimum round rod 3'-0" 3'-6" 6'-0" latch as required finished grade CHAINLINK FENCE NTS DOUBLE SWING GATE NTS concrete footing 12"12" 3/8" minimum round rod 3'-0" 3'-6" 6'-0" latch as required finished grade SINGLE SWING GATE NTS ORNAMENTAL FENCING - 6' HEIGHT SEE ARCHITECTURAL PLANS NTS NOTE: SEE ARCHITECTURAL PLAN SHEET A-005 FOR A GATE HARDWARE SCHEDULE.U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4500.dwg PLOTTED: 1/23/2026 3:32 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 01-03-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS4500 TOTAL SHEETS 42    1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOLBUILDING EXPANSIONSITE PLAN190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTSITE DETAILS CONCRETE SIDEWALK NTS 4" CONCRETE 4" DENSE GRADED STONE (21B) COMPACTED SUBGRADE 2.0% MIN 12" 21B COMPACTED SUBGRADE 20' GRAVEL ACCESS ROAD 4.0% UD-4 NOTES: 1. 4" MINIMUM, PROVIDED ATTAINING 4" OF AGGREGATE ON TOP OF PIPE 2. OUTLET PIPES ARE TO BE INSTALLED ON 2% MIN. (3% DESIRABLE) GRADE AND LOCATED EVERY 350' MAXIMUM OR AS NOTED ON PLANS. GEOTEXTILE DRAINAGE FABRIC (OVERLAP 1' AT TOP) 4" PIPE OUTLET PIPE WITH "RODENT PROOF" COVER/GRATE .25'#57 AGGREGATE, #8 AGGREGATE OR CRUSHED GLASS MEETING #8 GRADATION REQUIREMENT, IF REQUIRED BASED UPON ON-SITE SOIL CONDITIONS. EMERGENCY ACCESS ROAD NTS HANDICAP SIGN DETAIL NTS 2' GRASS SHLDR NOTE: “FOUNDATION DRAINS SHALL DAYLIGHT WHERE APPROPRIATE SO AS TO HAVE POSITIVE DRAINAGE AWAY FROM THE STRUCTURE AND TO NOT CREATE AN ADVERSE CONDITION SUCH AS EROSION AND/OR TRIP OR FALL HAZARDS.”U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS4500.dwg PLOTTED: 1/23/2026 3:32 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS4500 TOTAL SHEETS 42 ----  1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOLBUILDING EXPANSIONSITE PLAN190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTSITE DETAILS WATERLINE - A HORZ: 1" = 40' | VERT: 1" = 4' 720 725 730 735 740 745 750 720 725 730 735 740 745 750 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 25+50 26+00 26+50 27+00 27+50 28+00 28+50 29+00 WATERLINE - B HORZ: 1" = 40' | VERT: 1" = 4' 725 730 735 740 745 750 725 730 735 740 745 750 29+80 30+00 30+50 30+80 FIN. GRADE EX. GRADE 48" MIN COVER WATERLINE "A" - 8 " C L - 5 2 D I P STA=28+17.19 - 22.5° HORIZONTAL BENDSTA=22+99.56 - 45° HORIZONTAL BENDSTA=23+30.23 - 45° HORIZONTAL BENDSTA=26+20.44 - 45° HORIZONTAL BENDSTA=22+45.32 - 8" TEE W/GV (3)START OF W/L BSTA=24+12.93 - 8" TEE W/GV (3)STA=22+49.32 - 8" GVWATER L I N E " A " - 8 " C L - 5 2 D I P WATERLINE "B" - 8" CL-52 DIP EX. GRADE STA=24+85.98 - AIR RELEASE VALVESTA=19+24.80 - 45°HORIZONTAL BENDEX. 8" DIP STA=26+38.11 - SAN FM (CROSSING)COMBINED 3" DOMW METER & 6" FIRE METER SERVICE VAULT STA=28+74.09 - PROPOSED BUILDINGSTA=24+49.99 - EX 6" GAS MAINSTA=24+55.97 - EX 12" GAS MAINEXISTING 50' GAS EASEMENT DB 234 PG 359 STA=19+17.36 - CUT-IN CONNECTION #1(1) 8" GATE VALVECOUNTY SCHOOL BOARDOF FREDERICK COUNTYBRIAN J. HESTER, TRUSTEEROW / ESMT - DB 658 PG 88⅊ ⅊ 18" CLEAR 48" MIN COVER STA=30+65.38 - CUT-INCONNECTION #2STA=27+68.03 - 8" X 8" TEESTA=27+97.68 - 22.5° HORIZONTAL BENDSTA=27+62.96 - 22.5° HORIZONTAL BENDSTA=28+48.52 - 45° HORIZONTAL BENDSTA=28+58.49 - 45° HORIZONTAL BEND15" CLEAR EX GAS MAINS ASSUME 36" COVER TEST PITS REQ. WATERLINE - C HORZ: 1" = 40' | VERT: 1" = 4' 720 725 730 735 740 745 720 725 730 735 740 745 9+75 10+00 10+50 10+75 EX. GRADE 48" MIN COVERWATERLINE "C " - 8 " CL -52 D IP STA=10+46.05 - FHYD ASSMSTA=27+72.08 -(1) 4" GV DOM(1) 8" GV FIRESTA=27+73.49 - 8" X 6" REDUCER2 1 2 " DOM LINE 6" FIRE LINE FIN. GRADESTA=30+67.42 - 8" X 6" REDUCERSTA=30+54.38 - 45° HORIZONTAL BENDSTA=30+65.38 - 45° HORIZONTAL BENDSTA=19+17.36 - 45°HORIZONTAL BENDSTA=10+40.67 -8" X 6" REDUCERSTA=10+38.56 - 8" GV6" CL-52 DIP STA=27+70.37 - 8" X 4" TEEU:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS5100.dwg PLOTTED: 1/23/2026 3:33 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 07-14-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 68B0ITTE' )2R RE9IEW -- C6 TOTAL SHEETS 42    1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 226040I''LET2WN ELE0ENTAR< 6C+22L190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANWATER MAIN PROFILES (CITY OF WINCHESTER) NOTES: 1.PROPOSED WATER LINE CONSTRUCTION ACTIVITIES AND MATERIALS: THE CONTRACTOR SHALL CONFORM THE CITY OF WINCHESTER'S PUBLIC SERVICES STANDARDS MANUAL (CURRENT VERSION AT THE TIME OF CONSTRUCTION). OR AS OTHERWISE DIRECTED BY THE CITY'S UTILITY ENGINEER / INSPECTOR 2.AS A GENERAL GUIDELINE, STANDARDS SHALL BE THOSE SET FORTH IN WATERWORKS REGULATIONS, VIRGINIA DEPARTMENT OF HEALTH, TITLE 12, AGENCY 5, CHAPTER 590 OF THE VIRGINIA ADMINISTRATIVE CODE (VAC). 3.WHEN THE CITY OF WINCHESTER STANDARDS DIFFER FROM STATE AND/OR FEDERAL REQUIREMENTS, THE MOST STRINGENT REQUIREMENT SHALL APPLY. 4.WATER AND FIRE PROTECTION DISTRIBUTION FACILITIES ARE TO BE PROVIDED SOLELY FOR THE PURPOSE OF SUPPLYING POTABLE WATER AND FIRE PROTECTION. UNDER NO CIRCUMSTANCES SHALL CROSS CONNECTIONS BE ALLOWED TO UNAPPROVED WATER FACILITIES. 5.ANY CONTRACTOR THAT WILL PERFORM WATER MAIN TAPS, WORK WITHIN WATER MAIN EASEMENTS OR MAKE ROAD CUTS FOR THE PURPOSE OF WORKING ON THE WATER MAIN, MUST HAVE CLASS A, CONTRACTOR'S LICENSE. THE CONTRACTOR MUST HAVE 3 YEARS OF WATER EXPERIENCE, WHICH MAY BE REQUESTED BY THE CITY PRIOR TO ALLOWING WORK TO COMMENCE. 6.THE CONTRACTOR MUST NOTIFY THE CITY AT LEAST 5 WORKING DAYS IN ADVANCE OF AN ANTICIPATED SHUTOUT. THE CONTRACTOR MUST NOTIFY ALL CUSTOMERS AFFECTED BY A SHUTOUT IN WRITING AT LEAST 48 HOURS IN ADVANCE. THE NOTIFICATION MUST GIVE THE DATE, TIME, ANTICIPATED LENGTH CUSTOMER MAY BE WITHOUT WATER AND A BRIEF REASON FOR THE SHUTOUT. A COPY OF THE NOTICE MUST BE GIVEN TO THE CITY INSPECTOR. 7.THE NEW 8" FIRE LINE AND HYDRANT(S) SHALL BE PRESSURE TESTED AND INSPECTED BY THE CITY OF WINCHESTER, PRIOR TO DECOMMISSIONING AND REMOVAL OF THE EXISTING 6" FIRE LINE AND HYDRANT(S), AND / OR VACATION OF EASEMENTS.U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS5150.dwg PLOTTED: 1/23/2026 3:33 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 03-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 S8%0,TTE')O55E9,E: &S TOTAL SHEETS 42    1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOLBUILDING EXPANSIONSITE PLAN190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTWATER DETAILS (CITY OF WINCHESTER) 15" CLEAR SAN. FORCE MAIN (PRIVATE) HORZ: 1" = 40' | VERT: 1" = 4' 715 720 725 730 735 740 745 750 715 720 725 730 735 740 745 750 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00RIM=727.41PS2 - 48" WET WELLINV IN 722.50 (CO1)INV OUT 722.80 (FM)9+98.48RIM=735.88EX-D - EX 48" MHINV IN 729.37 (FM FRM PS2)INV IN 728.87 (EX-C)INV OUT 728.77 (EX-E)17+53.36EX. GRADE 48" MIN. COVER OVER FM PR. S A N. F O R C E M AI N 1.5" SDR-11 H D P E ( P RI V A T E) SAN. LATERAL CO1 - CO3 HORZ: 1" = 40' | VERT: 1" = 4' 715 720 725 730 735 740 715 720 725 730 735 740 9+80 10+00 10+50 11+00 11+50RIM=728.08CO1 - 6" C/OINV IN 724.90 (CO1A)INV IN 723.50 (CO2)INV OUT 723.50 (PS2)9+47.90SAN LATERAL CO1 - CO1A HORZ: 1" = 40' | VERT: 1" = 4' 715 720 725 730 735 740 715 720 725 730 735 740 9+80 10+00 10+50 10+80 5.00' - 6" SDR-26 @ 2.00%RIM=728.78CO3 - 6" C/OINV IN 725.70 ()INV OUT 725.70 (CO2)11+11.7745.56' - 6" S D R - 2 6 @ 1.98%RIM=728.14CO2 - 6" C/OINV IN 724.80 (CO3)INV OUT 724.80 (CO1)10+66.2166.21' - 6" SD R - 2 6 @ 1.96% LFL = 728.80'RIM=728.08CO1 - 6" C/OINV IN 724.90 (CO1A)INV IN 723.50 (CO2)INV OUT 723.50 (PS2)10+0038.28' - 6" S D R - 2 6 @ 2.09%RIM=728.63CO1A - 6" C/OINV IN 725.70 ()INV OUT 725.70 (CO1)10+38.285.00' - 6" SDR-26 @ 2.00% LFL = 728.80' 8" SDR-35 HP = 734.80' 14+24.37 FIN. GRADE 50.58' - 6" S D R - 2 6 @ 1 . 9 8 %COUNTY SCHOOL BOARDOF FREDERICK COUNTYBRIAN J. HESTER, TRUSTEEROW / ESMT - DB 658 PG 88EXISTING 50' GAS EASEMENT DB 234 PG 359 16+66.30 = EX WATER LINE - 6" PVC14+69.73 = EX 12" GAS MAIN14+63.72 = EX 6" GAS MAINEX GAS MAINS ASSUME 36" COVER TEST PITS REQ.15+05.83 = PR WATER MAIN B - 8" CL-52 DIP12+88.89 = PR WATER MAIN B - 8" CL-52 DIP18" CLEAR18" CLEAR ⅊ ⅊ 24" CLEARSTA=14+24.63 - ARVU:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS5200.dwg PLOTTED: 1/23/2026 3:33 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 S8%MITTE' FOR REVIE: 1-3- CS TOTAL SHEETS 42    1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MI''LETO:N ELEMENTAR< SC+OOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANSANITARY SEWER PROFILES NOTES: 1.TEST PITS REQUIRED AT ALL EXISTING UTILITY CROSSINGS. 2.TEST PIT ACTIVITY SHALL BE COORDINATED WITH THE UTILITY OPERATOR. 3.NEW FORCE MAIN SHALL BE CONNECTED TO EXISTING MANHOLE BY KOR-N-SEAL OR SIMILAR AS APPROVED BY THE ENGINEERS. 4.EXISTING MANHOLE "D" SHALL BE RAVEN COATED. 5.PRIVATE FM SHALL BE CONSTRUCTED WITHIN EXISTING EASEMENT GRANTED TO THE OWNER AT DB 658 / PG 88. NOTES: 1.PUMP STATION SHALL BE PRIVATELY OWNED AND OPERATED BY FREDERICK COUNTY PUBLIC SCHOOLS. 2.MATERIALS FOR PRIVATELY OWNED SEWAGE COLLECTION MAY BE SUBSTITUTED, AT THE OWNER'S DISCRETION. 3.(PS2) PUMP STATION DISCHARGES TO EXISTING PRIVATE (FCPS OWNED) GRAVITY COLLECTION SYSTEM, WHICH DISCHARGES TO A PUBLICLY OWNED (MIDDLETOWN) SEWAGE PUMP STATION AT THE INTERSECTION OF MUSTANG LN. & RT-11. 4.PUMP STATION (PS2) DISCHARGE EXCEEDS 2,000 GPD AND WILL REQUIRE A CERTIFICATE TO CONSTRUCT (CTC) IN ACCORDANCE WITH DEQ'S PERMITTING REQUIREMENTS. 5.ELECTRIC SERVICE TO THE PUMP STATION IS 120V - 1-PHASE. 240V SERVICE IS NOT AVAILABLE FOR THIS PROJECT. TRENCH & BEDDING 120V 60HZ (SEE NOTE 5, THIS SHEET)U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS5600.dwg PLOTTED: 4/30/2014 1:23 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 01-03-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTOR ANDOWNER MUST BE NOTIFIED OF ANY DISCREPANCIES BEFOREPROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 S8B0ITTED )OR RE9IE:  CS TOTAL SHEETS 42    1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 226040IDD/ETO:N E/E0ENT$R< SCHOO/190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANSEWAGE PUMP STATION (PRIVATE) U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS5600.dwg PLOTTED: 4/30/2014 1:23 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb S8B0ITTED )OR RE9IE:  STORM SEWER STR 4.1 - 5.1 HORZ: 1" = 50' | VERT: 1" = 5' 705 710 715 720 725 730 735 740 745 750 705 710 715 720 725 730 735 740 745 750 9+50 10+00 10+50 11+00 STORM SEWER STR 1.1 - 1.2 HORZ: 1" = 50' | VERT: 1" = 5' 700 705 710 715 720 725 730 735 740 745 700 705 710 715 720 725 730 735 740 745 9+50 10+00 10+50 11+00 11+50 12+00 STORM SEWER STR 2.1 - 2.5 HORZ: 1" = 50' | VERT: 1" = 5' 710 715 720 725 730 735 740 745 750 755 710 715 720 725 730 735 740 745 750 755 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 STORM SEWER STR 2.2 - 3.2C HORZ: 1" = 50' | VERT: 1" = 5' 710 715 720 725 730 735 740 745 750 755 710 715 720 725 730 735 740 745 750 755 9+50 10+00 10+50 11+00 11+50 STORM SEWER STR 2.2 - 4.4 HORZ: 1" = 50' | VERT: 1" = 5' 705 710 715 720 725 730 735 740 745 750 705 710 715 720 725 730 735 740 745 750 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 STORM SEWER STR 2.3 - 2.3A HORZ: 1" = 50' | VERT: 1" = 5' 710 715 720 725 730 735 740 745 750 755 710 715 720 725 730 735 740 745 750 755 9+50 10+00 10+50 11+001.1 - ES-1 (24")INV OUT = 719.0010+0074.00' - 24" HDPE @ 1 . 3 5 %TOP = 723.501.2 - 60" RISER (W/TRASH RACK)INV OUT 720.00 (1.1)10+742.1 - ES-1 (24")INV OUT = 723.0010+00.0438.10' - 24" HDPE @ 1.31%TOP = 726.852.2 - 24" DRAIN BASIN (GRATE)INV IN = 723.50 (4.1)INV IN = 723.50 (2.3)INV IN = 723.50 (3.1)INV OUT = 723.5010+38.1467.57' - 24" HDPE @ 0.74%TOP = 728.112.3 - DI-3B (4' RT)INV IN = 724.00 (2.4)INV IN = 724.83 (2.3A)INV OUT = 724.0011+05.7278.63' - 18" HDP E @ 1 . 5 3 %TOP = 730.902.4 - 36" DRAIN BASIN (JUNC)INV IN = 725.20 (2.5 (EX1.2))INV OUT = 725.2011+84.35124.20' - 18" HDPE @ 7.31 %TOP = 741.782.5 (EX1.2) - 48" MHINV IN = 734.38 ()INV IN = 735.68 (I-46)INV OUT = 734.28INV OUT = 734.2813+08.55117' - 15" RCP CL III @ 0 . 9 8 % 67.57' - 24" HDPE @ 0.74%TOP = 728.112.3 - DI-3B (4' RT)INV IN 724.00 (2.4)INV IN 724.83 (2.3A)INV OUT 724.00 (2.2)10+0014.12' - 8 " HDPE @ 3.31%TOP = 728.652.3A - 8" COINV OUT = 725.3010+14.1238.10' - 24" HDPE @ 1.31%TOP = 726.852.2 - 24" DRAIN BASIN (GRATE)INV IN 723.50 (4.1)INV IN 723.50 (2.3)INV IN 723.50 (3.1)INV OUT 723.50 (2.1)10+0033.50' - 15" HDPE @ 0.75%TOP = 728.143.1 - 48" MHINV IN = 723.75 (3.2)INV OUT = 723.7510+33.5233.58' - 15" HDPE @ 0.74%TOP = 727.753.2 - 24" DRAIN BASIN (GRATE)INV IN = 724.25 (3.2A)INV OUT = 724.0010+67.1034.20' - 12" HDPE @ 2.19%TOP = 728.643.2A - 6" COINV OUT = 725.0011+01.30STORM SEWER STR 4.2 - 6.1A HORZ: 1" = 50' | VERT: 1" = 5' 705 710 715 720 725 730 735 740 745 750 705 710 715 720 725 730 735 740 745 750 9+50 10+00 10+50 11+00 11+50 12+00 12+50 STORM SEWER STR 4.3 - 4.5 HORZ: 1" = 50' | VERT: 1" = 5' 705 710 715 720 725 730 735 740 745 750 705 710 715 720 725 730 735 740 745 750 9+50 10+00 10+50 11+00 38.10' - 24" HDPE @ 1.31%TOP = 726.852.2 - 24" DRAIN BASIN (GRATE)INV IN = 723.50 (4.1)INV IN = 723.50 (2.3)INV IN = 723.50 (3.1)INV OUT = 723.5010+0054.69' - 24" HDPE @ 0.55%TOP = 728.234.1 - 24" DRAIN BASIN (GRATE)INV IN = 723.80 (5.1)INV IN = 723.80 (4.2)INV OUT = 723.8010+54.6987.67' - 18" HDPE @ 0.46%TOP = 728.254.2 - 48" MHINV IN 724.20 (4.3)INV IN 724.20 (6.1)INV OUT 724.20 (4.1)11+42.3643.18' - 18" HDPE @ 0.46%TOP = 726.854.3 - VDOT DI-12INV IN = 724.40 (4.4)INV IN = 724.60 (4.5)INV OUT = 724.4011+85.5441.72' - 15" HDPE @ 0.48%TOP = 726.044.4 - ES-1 (15")INV OUT = 724.6012+27.2654.69' - 24" HDPE @ 0.55%TOP = 728.234.1 - 24" DRAIN BASIN (GRATE)INV IN = 723.80 (5.1)INV IN = 723.80 (4.2)INV OUT = 723.8010+0056.30' - 12" HDPE @ 2.1 3 %TOP = 727.755.1 - 24" DRAIN BASIN (GRATE)INV OUT 725.00 (4.1)10+56.3087.67' - 18" HDPE @ 0.46%TOP = 728.254.2 - 48" MHINV IN = 724.20 (4.3)INV IN = 724.20 (6.1)INV OUT = 724.2010+00148.07' - 12" HDP E @ 1 . 3 8 %TOP = 728.206.1 - 24" DRAIN BASIN (GRATE)INV IN = 726.25 (6.1A)INV OUT = 726.2511+48.0764.29' - 6" HDPE @ 13.61%TOP = 741.356.1A - 6" COINV OUT 735.00 (6.1)12+12.36PR GRADE EX GRADE TOP = 726.854.3 - VDOT DI-12INV IN = 724.40 (4.4)INV IN = 724.60 (4.5)INV OUT = 724.409+63.1136.89' - 1 2 " HDPE @ 2 . 7 1 %TOP = 726.794.5 - ES-1 (15")INV OUT = 725.6010+00PR GRADE EX GRADE PR GRADE EX GRADE PR GRADE EX GRADE PR GRADE EX GRADE PR GRADE EX GRADE PR GRADE EX GRADE PR GRADE EX GRADE 10 YR HGL 10 YR HGL 10 YR HGL 10 YR HGL10 YR HGL10 YR HGL 10 YR HGL U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS6100.dwg PLOTTED: 1/23/2026 3:34 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 S8%M,TTE' )OR RE9,EW 1-23-226 CS61 TOTAL SHEETS 42 ----  1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604M,''/ETOW1 E/EME1TAR< SC+OO/190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANSTORM SEWER PROFILES---- STORM SEWER STR 11.1 - 11.4 HORZ: 1" = 50' | VERT: 1" = 5' 715 720 725 730 735 740 745 750 755 760 715 720 725 730 735 740 745 750 755 760 9+50 10+00 10+50 11+00 11+50TOP = 743.5111.1 - 30" DRAIN BASIN W/ COVERINV IN 736.63 (11.2)INV IN 736.63 ()INV OUT 736.43 (10.1)10+0025.00' - 12 " HDPE @ 2.48%TOP = 741.7511.2 - 24" DRAIN BASIN (GRATE)INV IN = 737.25 (11.3)INV OUT = 737.2510+2538.62' - 1 2 " HDPE @ 2.72%TOP = 742.3511.3 - 24" DRAIN BASIN (GRATE)INV IN = 738.30 (11.4)INV OUT = 738.3010+63.62TOP = 742.5311.4 - EX 6" COINV OUT = 739.0010+94.3630.74' - 6" HDPE @ 2.28% STORM SEWER STR 10.1 - 10.2 HORZ: 1" = 50' | VERT: 1" = 5' 715 720 725 730 735 740 745 750 755 760 715 720 725 730 735 740 745 750 755 760 9+50 10+00 10+50 11+00 EX 96' - 12" RCP CL III @ 1.02%.10.1 - 12" WYE CONNECTIONINV IN = 735.47 (10.2)INV IN = 735.47 (11.1)INV OUT = 735.4710+0032.34' - 12" RCP CL III @ 1.02%TOP = 742.0310.2 - DI-3AINV OUT = 735.8010+32.34EX 95' - 12" RCP CL III @ 1.01% PR GRADE EX GRADE PR GRADE EX GRADE DEMOLISH EX STR & PLACE DRAIN BASINREMOVE PORTION OF EX 12" RCP & PLACE 12" x 12" x 12" CONCRETE WYE 10 YR HGL 10 YR HGL U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS6100.dwg PLOTTED: 1/23/2026 3:34 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 S8%M,TTE' )OR RE9,EW 1-2-202 &S101 TOTAL SHEETS 42 ----  1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604M,''/ETOW1 E/EME1T$R< S&+OO/190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANSTORM SEWER PROFILES---- 7357347 3 0 7 2 9 7 3 1 728 728728740 7377 3 8 7 3 9 730728729731732733735740734736737738739741725725 725 721722723724 724 724 726727730 735 740 732733 734 736 737 738 739 741 74 2 7327 2 8 7287 3 0 7 2 9 7 3 1 7 3 2 7 3 3 7 3 4 733 736737739739738 7257307237237247267277287297317327337307277287297317327337257307267277287297317 3 8 7 3 7 727 727728728 729 730 728 729 731 73 2 7 3 3 73472572272372472672772 5 72 3 72 4 72 4 72 672 7741740 74 1 735 736 736 736 737 7 3 8 739 730 73 5 74073 1 73 2 73 3 73 4 736 737 73 8 7 3 9 725 730 722723724 726727728729 731732733734 72 5 730 73 5 74 0 72372 4 72 672 7728729 73 173 2 73 3 73 4 7 3 6 73 7 73 8 739 725 730 735 723724 726727728729 731732733734 7207257257217227237237247247257237247267277347400.9%1.9%1.9%2.0%2.0%1.4%1.7%2.0%9.3%2.0%PR E - T R E A T M E N T FO R E B A Y SWM DETENTION POND (FOR QUANTITY ONLY)BIORE TEN T ION FAC I L I TY B 2.0% 2.0%10.0%4.2% 9.3% 1.2% 0.6% 1.9%2.0%0.7%2.0%725 730 721722723724726727728729 725 730 721722723724 726727728729 731 7257217227237247267270.9%0.4%4.0%1.4%1.2%0.9%1.5%1.0%1.0%1.8%1.8 %2.0%2.0%3:1 SLOP E 3:1 S L O P E3:1 SLOPE4:1 SLOPE3 : 1 S L O P E 3:1 SLOP E3:1 SLOPE3:1 SLOPE0. 4 %0.7% 2.0%1.3%2.3%2.0%7427437447447437437 4 3 7437437437420.7% 1. 7 % 2. 0 %73073 5 7 2 8 7297317 3 2 7 3 3 73 4 73 6 726726727727 7 2 7 7277277277307287297317327257307357267277287297317327337347367377387397257307267277287297 3 1 7317 3 2 7327 3 3 733740741 740741741725 7257257 2 3 723 724724 725725 721722 723 723724 724 2.0% LP KI T E X P 1, 1 2 7 S F GYM N A S I U M LFL = 7 2 8 . 8 0 'CLASSROOMS( 2 -STORY )LFL = 728 . 80 ' GRASS R E C A R E A ±30,800 S F B L D G E X P A N S I O N 21 , 8 7 9 S F 10'x12' STORAGE SHED W/ 11'x13' CONC. SLAB RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A ASPH A L T PLAY A R E A 4,500 S F M F L = 7 4 2 . 8 0 ' RESERVED AREA FUTR. FUEL ISLAND WARV 10' COW WATER ESMT (NEW) 10' COW WATER ESMT (NEW)10' COW WATERESMT (NEW)EX B-BALL COURT(ASPHALT)#190 MUSTANG LN.EX 1- STORY BRICK BUILDING"MIDDLETOWN ELEMENTARY SCHOOL"FFE = 742.8'LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPTEX. GAS MAIN (2X)EX. GAS MAIN (2X)EX. 50' GAS ESMTDB 234 PG 359MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57 " E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'S 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1N 33° 57' 54" W 453.18'INTERSTATE 81(LIM ITED ACCESS ROW) CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 EX. 6" DIP W/L EX. 6" W/M EX. 6" W/L (CITY OF WINCHESTER)FUEL I S L A N D 15' SETBACK (ACC. USE 165-401.07-C) 15' SETBACK (ACC. USE 165-401.07-C)60' SETBACK(ACC. USE 165-401 .07-C)15' SETBACK (ACC . USE 165 -401 .07 -C ) 5' SETBACK (PRKG 165-202.01-D (6))10' SETBACK (PRKG 165-202 .01-D (6)) 5' SETBACK (PRKG 165-202.01-D (6))5' SETBACK (PRKG 165 -202 .01 -D (6 ) ) EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX DRY DETENTION POND EX BIO-RET AEX. 50' GAS ESMTDB 234 PG 35960' SETBACK(ACC. USE 165-401 .07-C)10' SETBACK (PRKG 165-202 .01-D (6))15' SETBACK (ACC . USE 165 -401 .07 -C )5' SETBACK (PRKG 165 -202 .01 -D (6 ) )WP1FHWP1 WP1 WP1 WP1 WP1WP1WP1WP1WP1WP1EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1 LEGEND REPLACEMENT TREE PROPOSED TREE PROPOSED SHRUB CRITICAL ROOT ZONE REPLACEMENT TREES (TYP) (TOTAL OF 26) REPLACEMENT TREES (TYP) (TOTAL OF 26) (20) BM (18) BM (1) ZS (1) OV(1) OV (1) ZS (1) ZS (1) MS (2) OV (1) ZS (3) AR (3) AR (6) MS (4) QA (2) QC (3) QA (4) QC (1) OV (1) ZS 1669 16701671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 (1) OV (1) ZS (1) OV (1) OV(1) ZS 730 735 7317 3 2 73373473 5 7 3 6 7377367 3 7 73 8 739740 741 742 740 73973 8737 736 735 7347337327307297287277267257247237227217207197 1 9 7207 2 1 72 2 72 3 7 2 4 72572 6 727 729 728 729724 725 726 72772872973073173373874074 5 744743742741740739738737736735734733738739740733734735736737739 738737 740737738 73974074274174374474 4 743 740 743 7427417 4 0 74 2 7 4 1 74 0 739 738 74 1 7 4 0739738 7407397387377367377417 4 2 742742742741741 7 4 2 74 1 7 4 073973 8 73 7 74274174073973873 773673 57347 3 3 7 3 2 731730742735 730728727742 742743 72473874273 8 739 740 73973873973 7 73 6 733 73 4 735 7327317337207177177 1 8 718719721722723724715720712713714716717718719721722723724U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS7000.dwg PLOTTED: 1/23/2026 3:35 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 40'80' GRAPHIC SCALE 1"=40' SU%MITTE' )2R RE9IE: 1 &S TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MI''LET2:N ELEMENTAR< S&+22L190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANLANDSCAPE PLAN SHRUB PLANTING NOT TO SCALE 3x DIAMETER OF ROOT BALL OR CONTAINER SIZE 2" OF MULCH CREATE A SAUCER SHAPE WITH MULCH TO HOLD WATER SLOPE SIDES OF PLANTING HOLE REMOVE BURLAP OR WIRE BASKET FROM TOP 1/3 OF ROOT BALL TAMP SOIL AROUND ROOT BALL BASE FIRMLY TO PREVENT ROOT BALL FROM SHIFTING PRUNE ONLY DAMAGED OR DEAD BRANCHES TREE PLANTING NOT TO SCALE 3x DIAMETER OF ROOT BALL SET TRUNK PLUMB L DO NOT MULCH WITHIN 6" OF TRUNK 3" OF MULCH SLOPE SIDES OF PLANTING HOLE REMOVE BURLAP OR WIRE BASKET FROM TOP 1/3 OF ROOT BALL TAMP SOIL AROUND ROOT BALL BASE FIRMLY WITH FOOT PRESSURE TO PREVENT ROOT BALL FROM SHIFTING SECURE GUYS WITH RUBBER HOSE TO TRUNK PRUNE ONLY DAMAGED OR DEAD BRANCHES *(2) 2"x2" WOOD STAKES SET AT 180° (ALT: STEEL FENCE POSTS) C NOTES: 1.*STAKE ONLY TO PREVENT WIND TIP OR WHEN PLANTING ON STEEP SLOPES 2. REMOVE ALL TAGS AND ROPES FROM BRANCHES AND ROOT BALL. PITCH FROM C OF PLANTING AREA TYPICAL MULCH EDGING DETAIL4" MIN.MULCH LAYER TOPSOIL L PROVIDE EDGE WITH CLEAN, CRISP SEPARATION BETWEEN MULCHED BED AND ADJACENT SURFACE CONDITIONS CUT EDGE MINIMUM 4" BELOW GRADE TO RECEIVE MULCH TURF, SIDEWALK, OR CURB 2" MIN. MULCH LAYER NOT TO SCALE LANDSCAPE CALCULATIONS: PARKING LOT LANDSCAPING PERIMETER LANDSCAPING NEW PARKING LOT IMPERVIOUS AREA 25,570 SF EXISTING PARKING LOT IMPERVIOUS AREA 83,780 SF TOTAL PARKING LOT IMPERVIOUS AREA 104,423 SF REQUIRED PROVIDED PERIMETER PARKING LOT SHADE TREES -EXISTING IMPERVIOUS AREA 83,780 SF TO 100K SF = 16,220 SF 8.1 (1 PER 2,000 SF)9 PERIMETER PARKING LOT SHADE TREES -100K SF TO 104,423 SF = 4,423 SF 0.9 (1 PER 5,000 SF OVER 100K SF) 1 3' HIGH HEADLIGHT SCREENING YES YES INTERIOR LANDSCAPING TOTAL PARKING LOT AREA (EXISTING & PROPOSED)104,423 SF REQUIRED PROVIDED PARKING LOT LANDSCAPED AREA 5,221 SF (5.00%)16,814 SF (16.10%) NEW PARKING SPACES 45 NEW INTERIOR PARKING LOT SHADE TREES 4.5 (1 PER 10 SPACES)5 TOTAL NEW TREES 15 15 PROPOSED PARKING LOT PLANT LIST SYMBOL BOTANICAL NAME COMMON NAME SIZE SPACING QUANTITY TREES AR ACER RUBRUM 'OCTOBER GLORY'OCTOBER GLORY RED MAPLE 1 1/4" CAL. MIN.AS SHOWN 6 MS MAGNOLIA X SOULANGIANA SAUCER MAGNOLIA 1 1/4" CAL. MIN.AS SHOWN 7 OV OSTRYA VIRGINIANA HOP HORNBEAM 1 1/4" CAL. MIN.AS SHOWN 8 QA QUERCUS ACUTISSIMA SAWTOOTH OAK 1 1/4" CAL. MIN.AS SHOWN 6 QC QUERCUS COCCINEA SCARLET OAK 1 1/4" CAL. MIN.AS SHOWN 7 ZS ZELKOVA SERRATA ' GREEN VASE'GREEN VASE JAPANESE ZELKOVA 1 1/4" CAL. MIN.AS SHOWN 7 (26 REPLACEMENT TREES + 15 NEW TREES)TOTAL 41 SHRUBS BS BUXUS SEMPERVIRENS COMMON BOXWOOD 3 GAL. CONT. MIN./ 36" HT. MIN.4' O.C.38 INTERIOR PARKING LOT LANDSCAPING EXHIBIT TOP BER M = 7 2 5 . 0 0 'TOP BERM = 725.00'GYM N A S I U M LFL = 7 2 8 . 8 0 'CLASSROOMS( 2 -STORY )LFL = 72 8 . 8 0 ' B L D G E X P A N S I O N 21 , 8 7 9 S F ASPH A L T PLAY A R E A 4,500 S F M F L = 7 4 2 . 8 0 ' 8' S W L K 6' SW L K8' SWLK23.5'RAMPRET. WALL (30 LF)6' SWLK 50.00 ' 90.00'50.00 ' 90.00' ±5,24 0 S F HD A S P H A L T TRAS H E N C L O S U R E ±210 S F - H D C O N C CG-1 2 A CG-12 A6 ' SWLK 6 ' SWLK 12.00' 6.00' 6.00' TRANSFORMER (FURNISHED BY REC) 7.5' X 7.5' CONC PAD W/6' CLFCANOPYCANO P Y RI S E R R M LF LMASONRY WALLREF ARCHITECTURE63.72'63.72'20' G R A V E L 1 0 ' ELEC ESMT (REC )RAMPPR E L E C P A N E L & PS C O N T R O L L E R (W/G E N R E C E P T A C L E ) TRAPEZOIDAL CHANNEL 2'(W) BOTTOM x 12'(L) CLIA RIPRAP W/ FILTER FABRIC BASK E T B A L L G O A L (1 OF 2) 20 ' G R A V E LRAMPS 1 2 : 1 MAXW / HR - 1 HAND RA ILS 735 740 741 742 740 73973 8 737736 735 734733732730729728727738 74 2 74 1 74 0 739 738 74 1 7 4 0739 7397387377417 4 2 742742742741741 7 4 2 74 1 7 4 0 73873 773673 57347 3 3 7 3 2 731730REPLACEMENT TREES (TYP) (TOTAL OF 26) (20) BM (18) BM (1) ZS (1) OV(1) OV (1) ZS (1) ZS (1) MS (2) OV (1) ZS (3) AR (3) AR (6) MS (2) QC (1) OV (1) ZS 1669 1673 1674 1675 1676 1677 (1) OV (1) ZS (1) OV (1) OV(1) ZS F.F.E. (742.79)COCOCOF.F.E. (742.78)SCOCO24" RCP ASPHALT ASPHALTASPHALTASPHALTCO N C . W A L K CO N C . W A L K CO N C . W A L K CONC. WALKCONC. WALKCONC. WALK6" PVC12" PVCF.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA 15" RCP12" RCP12"PVC18" RCPASPHALT EX. GAS MAIN (2X)EX. GAS MAIN (2X)S 34° 10' 25" E 722.06' EX. 6" W/M EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 EX DRY DETENTION POND CANOPYEX GLMEX. 50' GAS ESMTDB 234 PG 359WFDC ARV 10.00'U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS7500.dwg PLOTTED: 1/23/2026 3:35 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS7500 TOTAL SHEETS 42    1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOLBUILDING EXPANSIONSITE PLAN190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTLANDSCAPE NOTES, DETAILS, AND CALCULATIONS 00 30'60' GRAPHIC SCALE 1"=30' TREE PRESERVATION NARRATIVE: 1.SUPER SILT FENCE SHALL BE USED TO PROTECT TREE PRESERVATION AREAS SPECIFIED ON THIS PLAN. PRIOR TO CLEARING THE SITE, ROOT PRUNING SHALL PERFORMED UNDER THE SUPERVISION OF A CERTIFIED ARBORIST IN ACCORDANCE WITH THE E&S AND TREE PRESERVATION PLAN. ANY TREE ROOTS LARGER THAN 2” THAT ARE FOUND WHILE TRENCHING SHALL BE CUT BY A PROFESSIONAL ARBORIST TO MINIMIZE IMPACT ON TREES TO BE PRESERVED. AFTER TRENCH HAS BEEN DUG, ALL SILT OR SUPER SILT FENCING IS TO BE INSTALLED IN FULL CONFORMANCE WITH DETAIL PROVIDED AND THE TREE CONSERVATION PLAN. BILINGUAL SIGNS SHALL BE POSTED AT AN INTERVAL NOT TO EXCEED 50' BETWEEN SIGNS FOR THE ENTIRE LENGTH OF SILT OR SUPER SILT FENCE. SIGNS SHALL BE IN PLACE THROUGHOUT ALL PHASES OF CONSTRUCTION. 2.ONLY AFTER TREE PRESERVATION MEASURES HAVE BEEN INSTALLED SHOULD SPECIFIED TREES BE REMOVED FROM SITE. 3.TREES ON THE EDGE OF THE LIMITS OF CLEARING SHALL BE CUT DOWN BY HAND WITH A CHAIN SAW. TO AVOID DAMAGING TREES TO THAT ARE SHOWN TO REMAIN. NO TREE SHALL BE FELLED, PUSHED OR PULLED INTO TREE PRESERVATION AREAS. STUMPS SHALL LEFT IN PLACE AS REQUIRED. LAND CLEARING OPERATION NOTES: GENERAL TREE PROTECTION 1.TREES BEING REMOVED SHALL NOT BE FELLED, PUSHED, PULLED OR OTHERWISE INTO TREE PRESERVATION AREAS. EQUIPMENT OPERATORS SHALL NOT CLEAN ANY PART OF THEIR EQUIPMENT BY SLAMMING IT AGAINST THE TRUNKS OF TREES TO BE RETAINED. 2.TREES ON THE EDGE OF THE LIMITS OF CLEARING SHALL BE CUT DOWN BY HAND WITH A CHAIN SAW. REMAINING STUMPS SHALL EITHER BE LEFT IN PLACE OR GROUND DOWN WITH A STUMP GRINDER. 3.TREES APPROVED TO BE REMOVED BY URBAN FORESTER STAFF DURING PRE-CONSTRUCTION WALK-THROUGH SHALL BE REMOVED DURING THE SUBJECT SITE'S INITIAL LAND CLEARING OPERATION. 4.THE REMOVAL OF ANY TREE SHOWN TO BE SAVED ON THE TREE PRESERVATION PLAN MUST BE PRE-APPROVED BY THE URBAN FORESTER. DIRECTOR IN WRITING AND IN SOME CASES MAY REQUIRE A REVISION TO THE APPROVED TREE PRESERVATION PLAN. 5.TREE PROTECTION MEASURES IDENTIFIED WITH THIS PLAN SHALL BE INSTALLED PRIOR TO ANY CLEARING AND GRADING ACTIVITIES. HOWEVER, CLEARING WITH HAND MACHINERY IN ACCORDANCE WITH THE APPROVED TREE PRESERVATION PLAN, NARRATIVE AND DETAILS MAY BE PERMITTED WITH PRIOR APPROVAL FROM URBAN FORESTER DIRECTOR. ALL CONSTRUCTION PERSONNEL SHALL HAVE A WORKING UNDERSTANDING OF THE LAND CLEARING OPERATION REQUIREMENTS OF THIS PLAN PRIOR TO CONDUCTING SITE WORK. 6.BILINGUAL SIGNS SHALL BE POSTED AND MAINTAINED AT THE LIMITS OF CLEARING NOT TO EXCEED A SPACING INTERVAL OF 50' BETWEEN SIGNS. SIGNS SHALL CLEARLY STATE THAT PRESERVATION AREAS ARE TO BE LEFT UNDISTURBED. THE SIGNS SHALL REMAIN POSTED THROUGHOUT ALL PHASES OF CONSTRUCTION. UNDER NO CIRCUMSTANCES SHALL SIGNS BE NAILED OR ATTACHED TO TREES OR OTHER VEGETATION TO BE PRESERVED IN ANY MANNER. SEE SIGN DETAIL THIS SHEET. PRE-CONSTRUCTION: 1.THE TREE PRESERVATION PLAN SHALL BE APPROVED BY FREDERICK COUNTY PRIOR TO ANY CLEARING AND GRADING ACTIVITIES. 2.THE APPLICANT SHALL RETAIN THE SERVICES OF A CERTIFIED ARBORIST DURING ALL PHASES OF CONSTRUCTION (PRE-CONSTRUCTION THROUGH POST CONSTRUCTION). PRIOR TO THE PRE-CON MEETING, THE LIMITS OF CLEARING AND GRADING SHALL BE MARKED WITH A CONTINUOUS LINE OF FLAGGING. DURING THE PRE-CON MEETING, THE LIMIT OF CLEARING AND GRADING LINE SHALL BE WALKED BY THE CERTIFIED ARBORIST AND A URBAN FORESTER REPRESENTATIVE TO DETERMINE WHERE ANY ADJUSTMENTS TO THE LIMITS OF CLEARING AND GRADING NEED TO BE MADE TO INCREASE THE SURVIVABILITY OF ADJACENT TREES. ALL PRE-CONSTRUCTION ACTIVITIES DESCRIBED HEREIN SHALL BE PERFORMED PRIOR TO THE PRE-CONSTRUCTION MEETING. FAILURE TO COMPLY WITH THIS REQUIREMENT MAY RESULT IN PROJECT DELAYS. 3.TREES LOCATED WITHIN TREE PRESERVATION AREAS THAT HAVE BEEN PRE-IDENTIFIED ON THE APPROVED TREE PRESERVATION PLAN AS “DEAD”, “POOR CONDITION”, OR “POTENTIAL HAZARD” SHALL BE EVALUATED FOR REMOVAL BY URBAN FOREST MANAGEMENT STAFF DURING THE PRE-CONSTRUCTION WALK-THROUGH. 4.THE URBAN FORESTER MAY IDENTIFY ADDITIONAL TREES THAT HAVE BECOME A MAINTENANCE NUISANCE OR A HAZARD DURING THE PRE-CONSTRUCTION WALK-THROUGH OR ANY OTHER INSPECTION OF THE SITE. TREES SHALL BE REMOVED BY HAND WITH A CHAINSAW AND THE.STUMPS LEFT IN PLACE UNLESS DEEMED HAZARDOUS. THE REMOVAL OF THE TRUNK OR BRANCHES OF THE FELLED TREE(S) IS NOT REQUIRED WITHIN WOODED AREAS, UNLESS SPECIFICALLY REQUIRED BY THE DIRECTOR. 5.TREE PROTECTION FENCING AND SIGNAGE SHALL BE INSTALLED IN ACCORDANCE WITH THIS PLAN BEFORE A PERMIT CAN BE ISSUED FOR ANY LAND DISTURBANCE ACTIVITIES (TO INCLUDE THE DEMOLITION OF EXISTING STRUCTURES). CONSTRUCTION PHASE: 1.THREE (3) DAYS PRIOR TO THE COMMENCEMENT OF ANY CLEARING, GRADING OR DEMOLITIONS ACTIVITIES, BUT SUBSEQUENT TO THE INSTALLATION OF THE TREE PROTECTION DEVICES, URBAN FORESTER SHALL BE NOTIFIED AND GIVEN THE OPPORTUNITY TO INSPECT THE SITE TO ENSURE THAT ALL TREE PROTECTION DEVICES HAVE BEEN CORRECTLY INSTALLED. IF IT IS DETERMINED THAT THE FENCING HAS NOT BEEN INSTALLED CORRECTLY, NO GRADING OR CONSTRUCTION ACTIVITIES SHALL OCCUR UNTIL THE FENCING IS INSTALLED CORRECTLY, AS DETERMINED BY URBAN FORESTER. 2.THE APPLICANT SHALL RETAIN THE SERVICES OF A CERTIFIED ARBORIST OR REGISTERED CONSULTING ARBORIST TO MONITOR ALL CONSTRUCTION WORK RELATING TO TREE PRESERVATION EFFORTS IN ORDER TO ENSURE CONFORMANCE WITH ALL TREE PRESERVATION REQUIREMENTS AND URBAN FORESTER APPROVALS. THE MONITORING SCHEDULE IS PROVIDED ON THIS SHEET (SHEET 11), AND SHALL BE REVIEWED AND APPROVED BY URBAN FORESTER. 3.TREES AND FORESTED AREAS SHALL BE PROTECTED OR MANAGED DURING ALL PHASES OF CONSTRUCTION IN ACCORDANCE WITH THE PROVISIONS OF THIS SECTION AND THE APPROVED TREE PRESERVATION PLAN AND NARRATIVE. 4.TREES AND FORESTED AREAS SHALL BE PROTECTED AND MANAGED DURING ALL PHASES OF CONSTRUCTION IN A MANNER THAT WILL ENSURE THESE RESOURCES ADAPT TO POST-DEVELOPMENT TREE AND FORESTED AREA STANDARDS AT THE END OF CONSTRUCTION ACTIVITIES. THESE STANDARDS REQUIRE THAT PRESERVED AREAS MAINTAIN THEIR ECOLOGICAL FUNCTIONALITY, HEALTH, AND CONDITION OF SUPER- AND SUB-CANOPY TREE SPECIES; WOODY SHRUBS, HERBACEOUS PLANTS, VINES, NONVASCULAR PLANTS AND EPIPHYTES; DECAYING LEAF LITTER, ROOT MASS, FUNGI, SOIL BIOTA AND SOIL CONDITIONS THAT ARE BE PRESENT. 5.IN ADDITION TO PROTECTING TREES, THE PERMITTEE SHALL PROTECT ALL UNDERSTORY PLANTS, LEAF LITTER AND SOIL CONDITIONS FOUND IN PRESERVED AND FORESTED AREAS EXCEPT AS MAY BE ALLOWED BY THE APPROVED TREE PRESERVATION PLAN NARRATIVE. 6.THE PERMITTEE SHALL MONITOR THE CONSTRUCTION SITE TO ENSURE THAT INAPPROPRIATE ACTIVITIES SUCH AS THE STORAGE OF CONSTRUCTION MATERIALS, DUMPING OF CONSTRUCTION DEBRIS, AND TRAFFIC BY CONSTRUCTION EQUIPMENT AND PERSONNEL DO NOT OCCUR WITHIN ANY PRESERVED AREAS. 7.ANY WORK ALLOWED BY THE APPROVED TREE PRESERVATION PLAN AND NARRATIVE TO OCCUR ADJACENT TO OR WITHIN AREAS TO BE PRESERVED, SUCH AS THE INSTALLATION OF SUPER SILT FENCE; REMOVAL OF TRASH OR DEBRIS; OR EXTRACTION OF TREES DESIGNATED TO BE REMOVED, SHALL BE COMPLETED IN A MANNER THAT ENSURES MINIMAL RISK TO TREES, UNDERSTORY SHRUBS, HERBACEOUS PLANTS, LEAF LITTER, ROOT SYSTEMS AND SOIL CONDITIONS. 8.THE PERMITTEE SHALL RESTORE UNDERSTORY PLANT MATERIALS, LEAF LITTER AND SOIL CONDITIONS TO THE SATISFACTION OF THE DIRECTOR IF THESE ARE FOUND TO BE DAMAGED, REMOVED OR ALTERED IN ANY WAY NOT SPECIFICALLY ALLOWED BY THE PROVISIONS OF THE TREE PRESERVATION PLAN AND NARRATIVE. 9.TREE PROTECTION DEVICES SHALL BE MAINTAINED UNTIL ALL WORK IN THE VICINITY HAS BEEN COMPLETED AND SHALL NOT BE REMOVED OR RELOCATED WITHOUT THE CONSENT OF THE DIRECTOR. IF THE DIRECTOR DEEMS THAT PROTECTIVE DEVICES PROVIDED ARE INSUFFICIENT, INSTALLATION OF ADDITIONAL DEVICES MAY BE REQUIRED. 10.HEAVY EQUIPMENT, VEHICULAR TRAFFIC, STOCKPILING MATERIALS OR DEPOSITION OF SEDIMENT SHALL NOT BE PERMITTED WITHIN PRESERVATION AREAS. 11.ANY POWER EQUIPMENT USE PRESCRIBED BY THE APPROVED TREE PRESERVATION PLAN NARRATIVE WITHIN TREE PRESERVATION AREAS SHALL BE LIMITED TO SMALL HAND OPERATED EQUIPMENT SUCH AS CHAINSAWS. 12.ANY WORK WITHIN PRESERVATION AREAS REQUIRING THE USE OF LARGER EQUIPMENT (SUCH AS, BUT NOT LIMITED TO, TREE TRANSPLANTING SPADES, SKID LOADERS, TRACTORS, TRUCKS, STUMP-GRINDERS, OR ANY ACCESSORY OR ATTACHMENT CONNECTED TO SUCH EQUIPMENT) SHALL NOT OCCUR UNLESS APPROVED IN WRITING BY THE DIRECTOR, OR UNLESS THE ACTIVITY HAS BEEN SPECIFICALLY ADDRESSED WITHIN THE APPROVED TREE PRESERVATION PLAN NARRATIVE. 13.TOXIC MATERIALS SHALL NOT BE STORED WITHIN 100 FEET OF VEGETATION TO BE RETAINED. 14.FIRES AUTHORIZED BY FAIRFAX COUNTY AIR POLLUTION CONTROL ORDINANCE, FIRE CODE, OR ANY OTHER STATE OR COUNTY LAW SHALL NOT BE PERMITTED WITHIN 100 FEET OF VEGETATED AREAS RETAINED UNLESS APPROVED BY THE DIRECTOR IN ACCORDANCE WITH THE ORDINANCE, CODE OR LAW. 15.NO PROTECTION DEVICES, SIGNS, UTILITY BOXES OR OTHER OBJECTS SHALL BE NAILED OR AFFIXED TO TREES OR VEGETATION TO BE PRESERVED. 16.IN THE EVENT THAT THE DIRECTOR DETERMINES A TREE OR PORTION THEREOF IS DEAD, DECLINING, HAZARDOUS, OR A MAINTENANCE NUISANCE DUE TO ONGOING CONSTRUCTION OR ENVIRONMENTAL CHANGES RESULTING FROM CONSTRUCTION; OR, IS HAZARDOUS TO LIFE OR PROPERTY BECAUSE OF CONDITIONS NOT RELATED TO CONSTRUCTION, THE DIRECTOR SHALL REQUIRE THE PERMITTEE TO REMOVE THE TREE OR PORTION THEREOF. THE PERMITTEE SHALL TAKE SUCH ACTION AS NECESSARY TO ELIMINATE THE TREE OR PORTION THEREOF CAREFULLY. THE PERMITTEE SHALL NOTIFY THE DIRECTOR OF ANY ACTIONS TAKEN OR PROPOSED TO BE TAKEN UNDER THIS SECTION. 17.THE MAIN TRUNKS OF DEAD TREES MAY BE ALLOWED TO REMAIN ON SITES WHERE THE DIRECTOR DETERMINES THAT IT MAY PROVIDE HABITAT OR OTHER WILDLIFE BENEFITS AND HAVE LITTLE OR NO POTENTIAL TO CAUSE DAMAGE TO PERSONS OR PROPERTY, OR TO OBSTRUCT STREAMS AND OTHER DRAINAGE. 18.WHEN EXCAVATING, TRENCHING, OR TUNNELING WITHIN THE CRITICAL ROOT ZONE (CRZ) OF A TREE, THE DEVELOPER SHALL EMPLOY A PROFESSIONAL ARBORIST TO ROOT PRUNE IMMEDIATELY BEYOND THE LIMITS OF EXCAVATION TO A DEPTH OF 18 INCHES TO 24 INCHES PRIOR TO EXCAVATION. ANY TREE ROOTS GREATER THAN 2 INCHES IN DIAMETER THAT ARE EXPOSED AND/OR DAMAGED AFTER EXCAVATION SHALL BE TRIMMED CLEANLY, AND COVERED WITH ORGANIC MULCH, TOPSOIL, OR OTHER SUITABLE MATERIAL TO PREVENT THE EXPOSED ROOTS FROM DRYING OUT. 19.ANY DAMAGE INFLICTED TO THE ABOVE OR BELOW-GROUND PORTIONS OF ANY TREES TO BE PRESERVED SHALL BE REPAIRED IMMEDIATELY. ALL DAMAGED BRANCHES IN THE CROWN SHALL BE REPAIRED. 20.ANY PORTION OF A TREE PRESERVATION AREA THAT IS DISTURBED WITHOUT PRIOR APPROVAL FROM THE DIRECTOR SHALL CAUSE WORK TO BE STOPPED IMMEDIATELY AND BE REPORTED TO THE PROJECT ARBORIST OR UFMO REPRESENTATIVE FOR INSTRUCTIONS ON HOW TO MITIGATE THE DISTURBANCE. POST-CONSTRUCTION: 1.THE DEVELOPER SHALL REQUEST AN INSPECTION OF THE SUBJECT PROPERTY AFTER CONSTRUCTION IS COMPLETED TO ENSURE ALL WORK HAS BEEN IN ACCORDANCE WITH THE APPROVED PLANS. PER SECTION 165-203.01.C - EXISTING TREE CREDITS: WE REVIEWED SEVENTEEN (17) TREES (PINES, MAPLES, MAGNOLIAS, CHERRY AND SWEETGUM) IN AND AROUND THE EXISTING PARKING LOT. AS SHOWN BELOW, ALL ARE IN FAIR CONDITION. THE TREES NEED ADDITIONAL PRUNING AND FERTILIZATION TO CONTINUE THEIR HEALTH. SCOPE OF WORK THE LANDSCAPE CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR AND EQUIPMENT TO COMPLETE ALL LANDSCAPE WORK AS SHOWN ON THE PLANS AND SPECIFICATIONS. NOTE: IF THE CONTRACTOR BIDS ACCORDING TO THE PLANT LIST, HE/SHE SHOULD THOROUGHLY CHECK THE PLANT LIST QUANTITIES WITH THE SYMBOLS DRAWN ON THE PLAN, TOP BE SURE THERE ARE NO DISCREPANCIES. IF THERE IS A DISCREPANCY BETWEEN THE DRAWING AND THE LIST ON THE PLANS, THE DRAWING TAKES PRECEDENCE. STANDARDS A.ALL PLANT MATERIAL WILL CONFORM TO THE CURRENT ISSUE OF THE AMERICAN STANDARD FOR NURSERY STOCK PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION (ANLA). B.PLANT MATERIAL MUST BE SELECTED FROM NURSERIES THAT HAVE BEEN INSPECTED AND CERTIFIED BY STATE PLANT INSPECTORS. C.COLLECTED MATERIAL MAY BE USED ONLY WHEN APPROVED BY OWNER'S REPRESENTATIVE. D.NOMENCLATURE WILL BE IN ACCORDANCE WITH HORTUS III BY L.H. BAILEY. SUBSTITUTIONS:PRE-BID IT IS THE LANDSCAPE CONTRACTOR'S RESPONSIBILITY TO MAKE EVERY REASONABLE EFFORT TO FIND THE MATERIAL SPECIFIED BY THE ARCHITECT. THE LANDSCAPE CONTRACTOR MAY OFFER SUBSTITUTIONS TO THE LANDSCAPE ARCHITECT FOR HIS/HER CONSIDERATION. THE LANDSCAPE CONTRACTOR WILL NOTIFY THE LANDSCAPE ARCHITECT IF THERE ARE KNOWN DISEASES OR INSECT RESISTANT SPECIES THAT CAN BE SUBSTITUTED FOR A SELECTED PEST-PRONE PLANT. THE CONTRACTOR SHALL SUBMIT A BASE BID AS PER PLAN PLUS PRICE CLARIFICATIONS FOR ALL RECOMMENDED SUBSTITUTIONS. SUBSTITUTIONS:POST-BID IT IS THE INTENT TO ELIMINATE POST-BID SUBSTITUTIONS. HOWEVER, IN THE EVENT THAT THE CONTRACT MATERIAL HAS BECOME UNAVAILABLE, AN APPROPRIATE SUBSTITUTION MUST BE APPROVED BY THE OWNER'S REPRESENTATIVE. UTILITIES AND UNDERGROUND FEATURES THE LANDSCAPE CONTRACT SHALL NOTIFY UTILITY COMPANIES AND/OR THE GENERAL CONTRACTOR IN ADVANCE OF CONSTRUCTION TO LOCATE UTILITIES. A.IF THERE IS A CONFLICT WITH THE UTILITIES AND THE PLANTING, THE LANDSCAPE ARCHITECT SHALL BE RESPONSIBLE FOR RELOCATING PLANTS PRIOR TO THE PLANTING PROCESS. ANY COST DUE TO RELOCATING AFTER PLANTING SHALL BE BORNE BY THE OWNER. DRAINAGE IF PLANTS ARE TO BE INSTALLED IN AREAS THAT SHOW OBVIOUS POOR DRAINAGE, AND THE PLANTS ARE INAPPROPRIATE FOR THAT CONDITION, THE LANDSCAPE CONTRACTOR SHALL BE RELOCATED, THE CONTRACT SHALL BE ADJUSTED TO ALLOW FOR DRAINAGE CORRECTION AT A NEGOTIATED COST, OR THE PLANT SELECTION MODIFIED BY THE LANDSCAPE ARCHITECT TO ACCOMMODATE THE POOR DRAINAGE SITUATION. WARRANTY A.THE STANDARD WARRANTY IS FOR A ONE (1) YEAR PERIOD, EXCLUDING BULBS, SOD AND ANNUALS, COMMENCING ON THE DATE OF INITIAL ACCEPTANCE. AL PLANTS SHALL BE ALIVE AND IN SATISFACTORY GROWTH AT THE END OF THE GUARANTEE PERIOD. B.BALLED AND BURLAPPED (B&B). 1. BALLED AND BURLAPPED PLANTS SHALL BE DUG WITH FIRM ROOT BALLS FREE OF NOXIOUS WEEDS. THERE SHOULD BE NO EXCESS SOIL ON TOP OF THE ROOT BALL OR AROUND THE TRUNK. 2. BALL SIZE SHALL BE IN ACCORDANCE WITH ANLA STANDARDS. 3. CALIPER AND HEIGHT MEASUREMENTS: IN SIZE GRADING B&B SINGLE-TRUNK TREES, CALIPER SHALL TAKE PRECEDENCE OVER HEIGHT. CALIPER OF THE TRUNK SHALL BE TAKEN 6" ABOVE THE GROUND LEVEL (UP TO INCLUDING 4" CALIPER SIZE) AND 12" ABOVE THE GROUND LEVEL OF LARGER TREES. FOR MULTIPLE-TRUNK TRESS, HEIGHT MEASUREMENT SHALL TAKE PRECEDENCE OVER CALIPER. C.CONTAINER-GROWN STOCK 1. THE SIZE OF CONTAINER-GROWN SHRUBS IS MEASURED BY HEIGHT AND WIDTH OF PLANT. CONTAINER-GROWN TREES ARE MEASURED BY THE SAME STANDARDS LISTED IN B.3 ABOVE. THE ROOT SYSTEM OF CONTAINER-GROWN PLANTS SHALL BE WELL-DEVELOPED AND WELL- DISTRIBUTED THROUGHOUT THE CONTAINER. 2. ALL CONTAINER-GROWN TREES AND SHRUBS THAT HAVE CIRCLING AND MATTED ROOTS SHALL BE TREATED IN THE FOLLOWING MANNER PRIOR TO PLANTING: USING A KNIFE OR SHARP BLADE, MAKE 4-5 CUTS, 1" DEEP, THE LENGTH OF THE ROOT BALL, TO CUT ALL CIRCLING ROOTS. SEE PLANTING PROCEDURES FOR ALL CONTAINER-GROWN TREES & SHRUBS IN THIS SECTION. 3. ALL CONTAINER-GROWN PLANTS SHOULD BE GROUPED AND WATERED DAILY UNTIL THEY ARE PLANTED IN THE LANDSCAPE, THE SOIL SHALL BE KEPT MOIST WITH THE EQUIVALENT OF ONE INCH OF RAINFALL PER WEEK. A.PRUNING SHALL BE DONE BEFORE PLANTING OR DURING THE PLANTING OPERATION. PRUNING DETAIL FOR TREES IN THIS SECTION. B.ALL PLANT MATERIAL IN TRANSIT SHALL BE COVERED TO KEEP MATERIAL FROM DRYING OUT. THE COVERING SHALL COMPLY WITH STATE AND LOCAL LAWS PERTAINING TO THE TRANSPORT OF MATERIALS. C.TREES SHALL BE PLACED IN AN UPRIGHT POSITION WITH THE ROOTBALL COVERED BY MULCH AND KEPT MOIST. TREES AND SHRUBS SHOULD NOT BE LEFT ON SITE UNPLANTED FOR MORE THAN 24 HOURS WITHOUT ADEQUATE WATER TO INSURE ROOTS SURVIVAL. INSPECTION A.PLANTS MAY BE SUBJECT TO INSPECTION AND APPROVAL BY THE OWNER OR OWNER'S REPRESENTATIVE AT THE PLACE OF GROWTH OR HOLDING YARD FOR CONFORMITY TO SPECIFICATION REQUIREMENTS AS TO QUALITY, SIZE AND VARIETY. B.PLANTS DAMAGED IN HANDLING OR TRANSPORTATION CAN BE REJECTED BY THE OWNER OR OWNER'S REPRESENTATIVE. C.STATE NURSERY INSPECTION CERTIFICATES SHALL BE FURNISHED TO THE LANDSCAPE ARCHITECT UPON REQUEST. PLANTING PROCEDURES FOR ALL CONTAINER-GROWN TREES & SHRUBS A.REMOVE THE PLANT EITHER BY CUTTING OR INVERTING THE CONTAINER. B.FOR UNTREATED PLASTIC CONTAINER GROWN PLANTS WITH CIRCLING ROOTS, USE A SHARP KNIFE TO MAKE 1" CUTS THE LENGTH OF THE ROOTBALL. C.PLANT SHRUB TO TREE A MINIMUM OF 1/8 OF THE HEIGHT OF THE ROOTBALL ABOVE EXISTING GRADE. D.APPLY A 2 TO 3" THICK LAYER OF APPROVED MULCH. KEEP MULCH 6" AWAY FROM THE TRUNK OF ALL TREES AND SHRUBS. E.PLANTS GROWN IN ROOT CONTAINMENT BAGS MUST HAVE THE BAGS REMOVED DURING THE PLANTING OPERATION. NO ADDITIONAL SLASHING OF THE ROOTBALL IS NECESSARY. MAINTENANCE OF LANDSCAPING NOTES: 1. ALL LANDSCAPED AREA SHALL BE MAINTAINED IN GOOD CONDITION BY OWNER. 2. REASONABLE PROVISIONS SHALL BE MADE FOR PROTECTION FROM VEHICLES, PEDESTRIANS, OR SHOPPING CARTS. 3. DEAD OR DYING VEGETATION SHALL BE REPLACED AT DIRECTION OF ADMINISTRATOR. 4. SHRUBS SHALL BE REPLACED AT A SIZE CONSISTENT WITH THAT OF EXPECTED FOR SPECIES AND TIME SINCE INSTALLATION. 5. TREES SHALL BE REPLACED AT A SIZE OF 0.5" CALIPER ABOVE 2" FOR EVERY YEAR SINCE INSTALLATION UP TO 5" CALIPER. GENERAL LANDSCAPING NOTES: 1. NO TREES OR SHRUBS SHALL BE PLACED ON FREDERICK WATER EASEMENTS. 2. ALL LANDSCAPING SHALL COMPLY WITH SECTION§165-203.01 LANDSCAPING REQUIREMENTS OF THE FREDERICK COUNTY ZONING ORDINANCE. 3. OWNER WILL ACCEPT FOR REVIEW, SUBSTITUTIONS FOR ALL LANDSCAPING PROVIDED THEY SATISFY APPLICABLE REGULATIONS. 4. OUTDOOR STORAGE AREAS FOR RVS, BOATS, AND TRAILERS ARE EXEMPT FROM LANDSCAPING REQUIREMENTS (§165-201.10(H)). LANDSCAPE NOTES: NOTES: 1. THIS SHEET SHALL BE USED FOR TREE PRESERVATION INFORMATIONAL PURPOSES ONLY. 2. SEE EROSION & SEDIMENT CONTROL PLAN AND TREE INVENTORY AND PRESERVATION NOTES SHEET FOR TREE INVENTORY DATA AND TREE PRESERVATION INFORMATION, INCLUDING TREE PROTECTION DETAILS AND NOTES. 3. TREES WERE INVENTORIED IN THE FIELD USING A COMBINATION OF FLAGGING AND TREE TAGS. 4. THE INVENTORY OF TREES LOCATED WITHIN AND ADJACENT TO THE 35 FOOT TREE INVENTORY ZONE (25 FT. OUTSIDE LIMITS OF DISTURBANCE AND 10 FT. INSIDE LIMITS OF DISTURBANCE) IS BASED ON A VISUAL ASSESSMENT PERFORMED BY A CERTIFIED ARBORIST (#MA-4931A) ON DECEMBER 23, 2025.. 5. DO NOT PERFORM ANY ARBORICULTURAL TREATMENTS TO ANY OFF-SITE TREES OR REMOVE ANY OFF-SITE TREES OUTSIDE OF THE PROJECT LIMITS WITHOUT PRIOR WRITTEN APPROVAL FROM ADJACENT OWNER.U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS7501.dwg PLOTTED: 1/23/2026 3:35 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS7501 TOTAL SHEETS 42 ----  1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANTREE INVENTORY AND NOTES WARV 10' COW WATER ESMT (NEW) 20' COW WATER ESMT. (NEW) 10' COW WATER ESMT (NEW)10' COW WATERESMT (NEW)EX B-BALL COURT(ASPHALT)LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPTEX. GAS MAIN (2X)EX. GAS MAIN (2X)MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57 " E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'S 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1N 33° 57' 54" W 453.18'INTERSTATE 81(LIM ITED ACCESS ROW) EX. 6" DIP W/L EX. 6" W/M EX. 6" W/L (CITY OF WINCHESTER)FUEL I S L A N D EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX DRY DETENTION POND EX BIO-RET AWP1FHWP1WP1WP1WP1WP1WP1WP1WP1WP1WP1 EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1 LP KI T E X P 1, 1 2 7 S F GYM N A S I U M LFL = 7 2 8 . 8 0 'CLASSROOMS( 2 -STORY )LFL = 728 . 80 ' GRASS R E C A R E A ±30,800 S F B L D G E X P A N S I O N 21 , 8 7 9 S F 10'x12' STORAGE SHED W/ 11'x13' CONC. SLAB RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A ASPH A L T PLAY A R E A 4,500 S F M F L = 7 4 2 . 8 0 ' RESERVED AREA FUTR. FUEL ISLAND 6' SW L K6' SWLK 50.00 ' 90.00'50.00 ' 90.00' 140.00'220.00'220.00'140.00'EX B-BALL COURT(ASPHALT)LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPTEX. GAS MAIN (2X)EX. GAS MAIN (2X)MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 N 39° 04 ' 57 " E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'S 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1N 33° 57' 54" W 453.18'INTERSTATE 81(LIM ITED ACCESS ROW) EX. 6" DIP W/L EX. 6" W/M EX. 6" W/L (CITY OF WINCHESTER)FUEL I S L A N D EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX DRY DETENTION POND EX BIO-RET AWP1FHWP1WP1WP1WP1WP1WP1WP1WP1WP1WP1 EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1 EX FIRE HYDRANT EX FIRE HYDRANT NEW FIRE HYDRANT NEW F.D.C. EXISTING NO PARKING / FIRE LANE SIGNS EXISTING 20' EMERGENCY ACCESS ROAD PROPOSED BOLLARDS W/CHAIN NO PARKING / FIRE LANE SIGNS (2) PROPOSED NO PARKING / FIRE LANE SIGNS PROPOSED 20' GRAVEL EMERGENCY ACCESS ROAD PROPOSED 20' GRAVEL EMERGENCY ACCESS ROAD FL FL FLFLPROPOSED NO PARKING / FIRE LANE SIGNS U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS8000.dwg PLOTTED: 1/23/2026 3:36 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 40'80' GRAPHIC SCALE 1"=40' SU%MITTE' )2R RE9IE: 1 &S8 TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MI''LET2:N ELEMENTAR< S&+22L190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANLIFE SAFETY PLAN NOTE: THE PROPOSED CANOPY SUPPORT COLUMNS DO NO INTERFERE WITH FDC. WARV 10' COW WATER ESMT (NEW) 20' COW WATER ESMT. (NEW) 10' COW WATER ESMT (NEW)10' COW WATERESMT (NEW)EX B-BALL COURT(ASPHALT)LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES DB 355 PG 71 ZONED:RA USE: EXEMPTEX. GAS MAIN (2X)EX. GAS MAIN (2X)EX. 50' GAS ESMTDB 234 PG 359N 39° 04 ' 57" E 724 .91 ' S 34° 10' 25" E 136.99'N 55° 49' 35" E 74.31'S 34° 10' 25" E 722.06'S 41° 30 ' 31" W 791 .93 ' N 34° 43' 54" W 239.56'C1N 33° 57' 54" W 453.18'INTERSTATE 81(LIM ITED ACCESS ROW) CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 EX. 6" DIP W/L EX. 6" W/M EX. 6" W/L (CITY OF WINCHESTER)FUEL I S L A N D EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX DRY DETENTION POND EX BIO-RET AEX. 50' GAS ESMTDB 234 PG 359WP1FHWP1 WP1 WP1 WP1 WP1WP1WP1WP1WP1WP1EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1 LP KI T E X P 1, 1 2 7 S F GYM N A S I U M LFL = 7 2 8 . 8 0 'CLASSROOMS(2 -STORY )LFL = 72 8 .80 ' GRASS R E C A R E A ±30,800 S F B L D G E X P A N S I O N 21 , 8 7 9 S F 10'x12' STORAGE SHED W/ 11'x13' CONC. SLAB RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A RELOCAT E D PLAY ARE A ASPH A L T PLAY A R E A 4,500 S F M F L = 7 4 2 . 8 0 ' RESERVED AREA FUTR. FUEL ISLAND U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS8100.dwg PLOTTED: 1/23/2026 3:36 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 S8%0ITTE' )2R RE9IE: 1 &S81 TOTAL SHEETS 42 NORTH   1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 226040I''/ET2:N E/E0ENTAR< S&+22/190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANPHOTOMETRIC PLAN N2T T2 S&A/E NOTE: ALL OUTDOOR LIGHTING SHALL CONFORM TO §165-201.07 AND BE DESIGNED, SHIELDED, AIMED, LOCATED AND MAINTAINED TO SHIELD ADJACENT PROPERTIES AND SHALL BE FULL-CUTOFF FIXTURES (§165-201.07(B)(1)). U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS8101.dwg PLOTTED: 1/23/2026 3:36 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS8101 TOTAL SHEETS 42    1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOLBUILDING EXPANSIONSITE PLAN190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTPHOTOMETRIC DETAILS EX B-BALL COURT(ASPHALT)LIM ITED ACCESS FENCE PIN 91-A-78A COUNTY SCHOOL BOARD OF FREDERICK COUNTY DB 510 PG 160 & DB 656 PG 85 15.0020 ACRES ZONE: RA PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT PIN 91-A-100 COMMONWEALTH OF VIRGINIA STATE BOARD OF COMMUNITY COLLEGES 16' FIRE LANEEX. 50' GAS ESMTDB 234 PG 359MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 INTERSTATE 81(LIM ITED ACCESS ROW) CL EX. POTOMAC EDISON CO. ESMT (UNSPECIFIED WIDTH) DB 331 PG. 310 EX 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 (END PORTION TO BE VACATED) EX. 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 PIN 84-A-78 BRIAN J. HESTER, TR. DB 862 PG 675 ZONED:RA USE: VACANT INTERSTATE 81(LIM ITED ACCESS ROW) PIN 84-A-78 BRIAN J. HESTER, TRUSTEE DB 862 PG 675 ZONED:RA USE: VACANT EX DRY DETENTION POND EX BIO-RET AEX. 50' GAS ESMTDB 234 PG 359WP1FHWP1 WP1 WP1 WP1 WP1WP1WP1WP1WP1WP1EX. 3-PHASE POLE MOUNT XFMR PROVIDED BY ELEC CO. TEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) EX SAN PS 1 EX 10' WATER ESMT. CITY OF WINCHESTER DB 686 PG 200 (BEGIN PORTION TO BE VACATED) 730 735 7317 3 2 73373473 5 7 3 6 7377367 3 7 7 3 8 739740 741 742 740 73973 8737 736 735 7347337327307297287277267257247237227217207197 1 9 7207 2 1 72 2 72 3 7 2 4 72572 6 727 729 728 729724 725 726 72772872973073173373874074 5 744743742741740739738737736735734733738739740733734735736737739 738737 740737738 739740742741743 74474 4 743 740 743 7427417 4 0 74 2 7 4 1 74 0 739 738 74 1 7 4 0739738 7407397387377367377417 4 2 742742742741741 7 4 2 74 1 7 4 073973 873 7 74274174073973873 773673 57347 3 3 7 3 2 731730742735 730728727742 742743 724738742739 740 73973873973 7 73 6 73 4 735 7327317337207177177 1 8 71871972172272372471572071271371471671771871972172272372474 2 730730740740740 740726726 726726 7 2 8 728 728 728 732732734 734 7347347 3 6736 736736738738 738738 742 742742742742744744 730740732732732734736738742744 7 3 073073073 0 740740740740724724 724 726728728728732 732 73273273 2 732734734734734 734 734736 736 736736736736736 736738738738738738738738 738 738 7387427 4 2 7207 2 0730 730730 73074074074 0 740 7187 1 8722 7227247247267 26 726726728 7287327327 3 2 73273473473473673673673873 8 73 8 742742740 732732732734736738742740740742 742 740 7407 4 0 740740 740 740 740736736738738 7387 3 8 738738738738 7427 4 2 742 742 7427 4 2 7 4 2 742742 742 7 4 2 742742 744744 74 4 74 4 74 4 7 4 0 740 74 0740740738738742742 742742742 744744744740 74 0 7 4 0 740738 738 738 73 8 74274274 2 730 7 4 0 732 734 7 3 6 73 8 740736736738738742720720730740722 722724 7247267287327347367 3 8 7 2 0 71872 2 724 72 6 41 35 HP 4114 4200 HP 3135 27 14 3184 32 113143 2616 H S G B H S G D HSG DHSG BHSG B HSG D STUDY POINT A STUDY POINT D STUDY POINT C STUDY POINT B DRAINAGE AREA C (TOTAL TO SP C) FORESTED = 0.09 AC (HSG B) FORESTED = 0.15 AC (HSG D) TURF = 2.17 AC (HSG B) TURF = 1.96 AC (HSG D) IMPERVIOUS = 0.20 AC (HSG B) IMPERVIOUS = 0.43 AC (HSG B) SUBTOTAL AREA = 5.00 AC DRAINAGE AREA B (TOTAL TO SP B) TURF = 0.23 AC (HSG D) FORESTED = 0.42 AC (HSG D) TOTAL AREA = 0.65 AC DRAINAGE AREA A (TOTAL TO SP A) TURF = 4.04 AC (HSG D) IMPERVIOUS = 2.45 AC (HSG D) SUBTOTAL AREA = 6.49 AC DRAINAGE AREA D (TOTAL TO STUDY POINT D) TURF = 0.63 AC (HSG B) TURF = 0.68 AC (HSG D) IMPERVIOUS = 0.01 AC (HSG D) TOTAL AREA = 1.32 AC 73 0 740 72 8 73 4 734 736 738 742 7 3 0 7 4 0 74 0 74 0 732 7347 3 6 7 3 8742742 720720730 71271471671871871872272272472472472673 2 734 7 2 0 7 2 0720722724 LAND COVER HATCH KEY FOREST LAND COVER (HSG B) MANAGED TURF LAND COVER (HSG B) FOREST LAND COVER (HSG C/D & HSG D) MANAGED TURF LAND COVER (HSG C/D& HSG D) DRAINAGE DIVIDES IMPERVIOUS LAND COVER (HSG B) IMPERVIOUS LAND COVER (HSG C/D& HSG D)U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS9200.dwg PLOTTED: 1/23/2026 3:37 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 40'80' GRAPHIC SCALE 1"=40' SUBMITTED )OR RE9IE: 1 CS TOTAL SHEETS 42 NORTH----  1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETO:N ELEMENTARY SC+OOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANPRE RE-DEVELOPMENT DRAINAGE PLAN---- 730740740724724726726 726 7 2 8 728 728732 734 734 7347 3 6736 736738738742 742742742744744 7307407327327327347367387427447 4 0 740 74 0740740738738742742 742742742 744744744740 74 0 7 4 0 740738 738 738 73 8 74274274 2 730 7 4 0 732 734 7 3 6 73 8 740736736738738742720720730740722 722724 7247267287327347367 3 8 7 2 0 72 2 724 72 6 HSG B HSG D H S G B H S G D HSG DHSG BDRAINAGE AREA C1 (TO FOREBAY) TURF = 0.30 AC (HSG B) TURF = 0.98 AC (HSG D) IMPERVIOUS = 0.25 AC (HSG B) IMPERVIOUS = 2.55 AC (HSG D) SUBTOTAL AREA = 4.08 AC DRAINAGE AREA C3 (DIRECT TO BIORETENTION B) TURF = 0.21 AC (HSG B) IMPERVIOUS = 0.07 AC (HSG B) SUBTOTAL AREA = 0.28 AC DRAINAGE AREA C2 (DIRECT TO DRY DETENTION POND) TURF = 0.20 AC (HSG B) TURF = 0.64 AC (HSG D) IMPERVIOUS = 0.18 AC (HSG D) FORESTED = 0.01 AC (HSG B) FORESTED = 0.02 AC (HSG D) SUBTOTAL AREA = 1.05 AC DRAINAGE AREA C4 (UN-DETAINED TO SP C) TURF = 1.56 AC (HSG B) TURF = 0.19 AC (HSG D) IMPERVIOUS = 0.08 AC (HSG B) FORESTED = 0.06 AC (HSG D) SUBTOTAL AREA = 1.89 AC DRAINAGE AREA B (TOTAL TO SP B) TURF = 0.16 AC (HSG D) TOTAL AREA = 0.16 AC DRAINAGE AREA A (TOTAL TO SP A) TURF = 2.19 AC (HSG D) IMPERVIOUS = 2.86 AC (HSG D) SUBTOTAL AREA = 5.05 AC DRAINAGE AREA D (TOTAL TO STUDY POINT D) TURF = 0.64 AC (HSG B) TURF = 0.43 AC (HSG D) IMPERVIOUS = 0.01 AC (HSG D) TOTAL AREA = 1.08 AC 7 2 0 7207207127147167 1 8 7187187227227247247307407227 2 4 7267 2 8732 734736738742730730 730 740 740740 74 0 726728 732 732 732 734 734734734 736 736 7 3 6 73 8738 738 7 3 8742742 73 4 734 734 730730 7267287327 3 2 732732 73 4 73 6 7 3 8 7307307227247267267287287327327347347367367387387 3 0 730 730728728 7 2 8 7 3 2 7 3 4 742 730 722 722 724 724 724724724 724726 728 72472672 8 72 8 728728 72 8 728740732734736738730 730 722 722 724 724726 726 728 728 732 73 2 734 73 4 740 740 736 736 736 7 3 8 724726728730728740 7327347367 3 8 STUDY POINT A STUDY POINT D STUDY POINT C STUDY POINT B DRAINAGE AREA C5 (TO DRY SWALE) TURF = 0.17 AC (HSG D) SUBTOTAL AREA = 0.17 AC F.F.E. (742.79)F.F.E. (742.78)EX B-BALL COURT(ASPHALT)F.F.E. (742.81)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)F.F.E. (742.79)LIM ITED ACCESS FENCE MUSTANG LN. 60' ROW (NON-EXCLUSIVE) DB 658 PG. 88 INTERSTATE 81(LIM ITED ACCESS ROW)INTERSTATE 81(LIM ITED ACCESS ROW) INV = 710.67' INV = 714.88' 121.7 8 ' - 3 6 " C M P @ 3 . 4 6 % E X R O O F D R A I N S K E T C H E D A P P R O X ( P E R R E C O R D ) EX DRY DETENTION POND EX BIO-RET AWP1FHWP1WP1WP1WP1WP1WP1WP1WP1WP1WP1 20' EMERGENCY ACCESS RD GRAVEL20'EX. 5' CO N C S / W RAMP RAMPRAMP 20' COW WATERESMTE X . F I R E L I N E - A - 6 " C L - 5 2 D I P E X . 1 " D O M W C T S P E T E X , C O M M , D A T A , A L A R M EX. 3-PHASE POLE MOUNT XFMR E X . 3 2 0 L F S A N F M ( P R I V ) 1. 2 5 " S D R - 1 1 H D P E EX. ELEC PANEL & PS CONTROLLER (W/GEN RECEPTACLE) EX. 6' X 6' GRAVEL PAD FOR PORT. GEN 240V / 6,500 WATT EX 6' HT - FENCEGATETEMP. MODULAR CLASSROOMS 744.00' FFE APPROVED SP#03-25 (UNDER CONSTRUCTION) 6' HT - FENCEEX 6' HT - FENCEEX SAN PS 1 5'2'23' RET. WALL (30 LF)50.00 ' 90.00'50.00 ' 90.00' 140.00'220.00'220.00'140.00' 12.00' 6.00' 6.00' 10' UGND UTIL ESMTMASONRY WALLREF ARCHITECTUREBRICK & GROUT EX INV OUTBRICK & GROUT EX INV IN (ROOF DRAINAGE) CORE-DRILL FOR NEW 18" HDPE INV OUT2.4 11.4 11.3 11.2 6.1A 6.1 2.2 4.1 1.2 4.4 11.1 2.1 1.1 4.5 1 0 ' ELEC ESMT (REC ) 2.3 3.1 3.2 2.5 (EX1.2) 4.3 4.2 5.13.2A 10.2 10.1 TRAPEZOIDAL CHANNEL 2'(W) BOTTOM x 12'(L) CLIA RIPRAP W/ FILTER FABRIC 10' 10.0 PR E - T R E A T M E N T FO R E B A Y SWM DETENTION POND (FOR QUANTITY ONLY)BIOR E TEN T ION FAC I L I T Y B LAND COVER HATCH KEY FOREST LAND COVER (HSG B) MANAGED TURF LAND COVER (HSG B) FOREST LAND COVER (HSG C/D & HSG D) MANAGED TURF LAND COVER (HSG C/D& HSG D) DRAINAGE DIVIDES IMPERVIOUS LAND COVER (HSG B) IMPERVIOUS LAND COVER (HSG C/D& HSG D)U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS9300.dwg PLOTTED: 1/23/2026 3:38 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 00 40'80' GRAPHIC SCALE 1"=40'SUBMITTED )OR RE9IE: 1 CS TOTAL SHEETS 42 NORTH----  1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETO:N ELEMENTARY SC+OOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANPOST RE-DEVELOPMENT DRAINAGE PLAN---- MS-19 COMPLIANCE SUMMARY TABLES VRRM COMPLIANCE SUMMARY U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS9500.dwg PLOTTED: 1/23/2026 3:39 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS9401 TOTAL SHEETS 42 ----  1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANMS-19 & VRRM COMPLIANCE---- STUDY POINT A STUDY POINT B STUDY POINT C Middletown Elementary School Building Expansion Stormwater Management Narrative Overview The "Middletown Elementary School Building Expansion" project site is generally located in Frederick County, Virginia within the Back Creek Magisterial District. This site is specifically located north of the "Laurel Ridge Community College", south of unimproved RA land, east of US Route 11 and unimproved RA land" and west of Interstate 81 This property is identified as property identification number 91-A-78A. This project proposes construction of a building expansion, an asphalt play area, and expansion & relocation of existing playground space. Additionally, this project proposes a new emergency access road along the rear of the school. Other improvements include new concrete sidewalks for access to the building expansion & circulation to the rest of the site as well as an associated SWM/BMP facility. Facilities for management of Stormwater Quantity and Stormwater Quality are proposed to meet regulatory requirements. The existing site has a mix of impervious, turf and forested land cover. Pre-ReDevelopment Conditions The existing elementary school is situated at a high point on site . The site discharges surface runoff at four (4) different locations. The drainage(s) flow to various Receiving Channels, which then convey stormwater further down gradient. Slopes range from less than 0.50% to approximately 15%. The site is generally bisected by a ridge oriented north to south. Runoff flowing west and southwest from the ridge is collected in the existing storm sewer system, which conveys it to an existing Dry Detention Pond, where it is detained for controlled release to Study Point A. Runoff flowing generally east from the ridge leaves the site at two (2) different locations. A small portion of this drainage sheet flows north east to Study Point B. The majority of this drainage flows off-site towards Interstate 81 where it is conveyed further through an existing culvert, being Study Point C. See the Pre-ReDevelopment Drainage Map (Sheet CS9200). Post-ReDevelopment Conditions Generally, Post-ReDevelopment Drainage Patterns are like Pre-ReDevelopment Drainage Patterns. The site still discharges surface runoff at four (4) different locations. Changes made to individual Drainage Areas are discussed in the Water Quantity Control (SWM) Section. All Disturbed Areas will be stabilized and have Managed Turf or Impervious Ground Cover. See the Post-ReDevelopment Drainage Map (Sheet CS9300). Water Quality Control (BMP) To meet Water Quality requirements, a single Level I Bioretention Facility and a single Level I Dry Swale have been designed and proposed. These facilities provide 100% of the total Phosphorus Reduction Requirement On-Site. See sheet CS9401 for more information. Water Quantity Control (SWM) Water Quantity requirements for Channel Protection and Flood Protection within the Limits of Analysis are satisfied with one (1) proposed Dry Detention Pond & one (1) existing Dry Detention Pond. Overall site design, in conjunction with existing and proposed Stormwater Management Facilities allow for Post-ReDevelopment Surface Runoff to be detained and released at a controlled rate. Peak Runoff rates are reduced at all Study Points during the 1, 2 & 10 YR-24HR Storm Events. In order to meet SWM Quantity & Quality requirements some change has been made to Pre-ReDevelopment drainage areas. Most significantly, runoff from the existing School Building Rooftop is diverted from the existing Dry Detention Pond it currently drains to, at Study Point A and is rerouted to the proposed Dry Detention Pond upstream of Study Point C. Portions of surface runoff to Pre-Redeveloped Study Points B and D have also be made to drain to the proposed Dry Detention Pond upstream of Study Point C. Channel Protection & Limits of Analysis for Channel Protection See the "MS-19 Compliance Summary" on Sheet CS9401 for a Summary of how Channel Protection & Limits of Analysis for Channel Protection are Satisfied at All Study Points. Sheet CS9402 offers detailed Analysis of each Study Point. Flood Protection & Limits of Analysis for Flood Protection See the "MS-19 Compliance Summary" on Sheet CS9401 for a Summary of how Channel Protection & Limits of Analysis for Channel Protection are Satisfied at All Study Points. Sheet CS9402 offers detailed Analysis of each Study Point. Summary The Water Quality Requirements are satisfied by achieving the required phosphorus load reduction through construction of On-Site BMP Facilities. The storm water quantity requirements (channel and flood protection) are satisfied at all Study Points. The VA Runoff Reduction Method (VRRM) v.4.1 was used to verify BMP requirements were met. HydroCAD v.10.20.7 software was used to evaluate stormwater runoff. The design engineer shall be required to certify that the stormwater management facilities have been constructed in accordance with the approved plan. STUDY POINT D U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS9500.dwg PLOTTED: 1/23/2026 3:39 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS9402 TOTAL SHEETS 42 ----  1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANSTORMWATER MANAGEMENT NARRATIVE & STUDY POINTANALYSIS---- DRY POND - PRINCIPAL RISER SECTION NOT TO SCALE TRASH RACK (SEE NOTE 3) EARTHEN BERM3:1 SIDE SLOPE3: 1 S IDE SLOPE TOP OF EMBANKMENT = 725.00 OUTFALL BARRELL 24" RCP CL. III (SEE NOTE 2) Notes: 1.Concrete Base & Inside Concrete Fill Provide Anti- Floatation Anchoring. Embed the Principal Riser at least 6" into the Concrete Base. 2.Install the Riser Outfall Pipe per ASTM C-443 (Bell & Singular Spigot Joints w/ Rubber Gaskets) 3.Plastic Solutions Inc. Round Series Trash Rack, Part #RS 60 (Bolted to Structure W/ 2" SS Anchor Bolts) (See Detail, This Sheet) FILL RISER TO FLOW LINE W/ 2.0' CONCRETE DRY POND- PRINCIPAL RISER PLAN NOT TO SCALE PLASTIC SOLUTIONS INC. ROUND SERIES TRASH RACK, PART # = RS 60 (NOT SHOWN, SEE DET, SH CS9503) DRY POND - PRINCIPAL RISER ELEVATION NOT TO SCALE 4"Ø ORIFICE INV = 720.00 OUTFALL BARRELL 24" RCP CL. III RECTANGULAR WEIR = 722.00 [24" (W) X 12" (H)] 6" MINIMUM WALL THICKNESS 6" MINIMUM WALL THICKNESS INV = 720.00' 8' EMBANKMENT PRINCIPAL RISER BOTTOM = 741.00' 12' Ø X 18" THICK CONC. BASE (SEE NOTE 1) FILL RISER W/ 2.0' CONCRETE TO THE FLOW LINE PRINCIPAL RISER CREST = 723.00 5' Ø RISER STRUCTURE PER AASHTO M199 5' Ø RISER STRUCTURE PER AASHTO M199℄OUTFALL PIPEFOOTING BOTTOM = 739.25' RECTANGULAR WEIR = 722.00 [24" (W) X 12" (H)] 4"Ø ORIFICE INV = 720.00 PLASTIC SOLUTIONS INC. ROUND SERIES TRASH RACK, PART # = RS 60 (SEE DET, SH CS9501) RECTANGULAR WEIR = 722.00 [24" (W) X 12" (H)] OUTFALL BARRELL 24" RCP CL. III 5' Ø RISER STRUCTURE PER AASHTO M199 4"Ø ORIFICE = 720.00 STORMRAX DEBRIS CAGE OR EQUAL (SEE DET, SH CS9501)U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS9500.dwg PLOTTED: 1/23/2026 3:39 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS9501 TOTAL SHEETS 42 ----  1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANDRY POND COMPUTATIONS & DETAILS---- 6' WEIR WIDTH 1.0' SECTION VIEW ALONG OUTFALL WEIR 9' LENGTH 3:1 NOTE: GABION STONE SIZE 4"-8" (AVERAGE 6") 1.5' 0.5' 7' MIN WIDTH OF FOREBAY @ WEIR APPROACH 9' LENGTH 3:1 6' LENGTH 6' LENGTH 9' LENGTH LOWER GABION BASKET (9' W X 1.0 H) LOWER GABION BASKET (6' W X 1.0' H) UPPER GABION BASKET (9' W X 1.5' H) FILL VOIDS WITH #57 STONE BETWEEN EDGE OF EXCAVATION AND GABION BASKETS PROPOSED GRADE NON-WOVEN GEO-TEXTILE FABRIC SEE TYP GABION BASKET DETAIL LOWER GABION BASKET (6' W X 1.0' H) UPPER GABION BASKET (9' W X 1.5' H) TYPICAL BIO-RETENTION FOREBAY OUTFALL DETAIL (6" HIGH WEIR) NOT TO SCALE 3.0' 2.0' BURIED DEPTH 0.5' 1.0' GABION WEIR INV = 0.00' 1.5' GABION WEIR TOP = +0.50' TOP OF UPPER GABION = +2.00' TOP OF EARTH BERM = +2.00' 1.0' SECTION VIEW THRU GABION BASKET WEIR IN OUTFALL WEIR BIO-RETENTION FOREBAY (PRE-TREATMENT FACILITY) NON-WOVEN GEO-TEXTILE FABRIC UPPER GABION BASKET (3' W X 1.5' H) LOWER GABION BASKET (3' W X 1.0' H) NON-WOVEN GEO-TEXTILE FABRIC GRAVEL DIAPHRAGM CLEAN WASHED #57 STONE PROPOSED GRADE SEE TYP GABION BASKET DETAIL TYPICAL GABION BASKETS NOT TO SCALE ISOMETRIC VIEWNote: Gabion Basket lengths will vary, but Shall be Multiples (1,2,3, or 4) of the 3 foot Basket Width. BASKET HEIGHT VARIES 1', 1.5' OR 3' (SEE PLAN DETAILS FOR HEIGHT) INDIVID U A L C E L L 3 ' LENGTH 3' B A S K E T W I D T H TOP/LID DIAPHRAGM GABION B A S K E T L E N G T H ( 3 ' , 6 ' , 9 ' O R 1 2' )Bio-Retention Soil MediaSump6" Cleanout RiserPerforated Underdrain12"Vented Cap Set 6" Above Water Storage Surface Elevation Connect Observation Well to Underdrain with a Vertical Tee Fitting Watertight PVC Cap on Upstream end of Underdrain 6" Cleanout RiserBIO-RETENTION CLEANOUT DETAIL NOT TO SCALE Perforated Underdrain12"Vented Cap Set 6" Above Water Storage Surface Elevation Connect Cleanout Riser to Underdrain with a 45° Wye & Fitting or Equivalent Watertight PVC Cap on Upstream end of Underdrain Bio-RetentionSoil MediaSump6" CLEANOUT RISER6" PERFORATED UNDERDRAIN24" Soil Media Layer (Bottom = 720.75) 3" Choker Stone Layer (Bottom = 720.50) 18" Stone Reservoir Layer (Bottom = 719.00) 24" Soil Media Layer (Top = 722.75) 3" Turf Layer (Top = 723.00) TOP OF BERM = 725.00 3" Thick Conc. Apron Cap = 724.50 Cleanout Riser See Bio-Retention Cleanout Detail BIO-RETENTION OBSERVATION WELL DETAIL NOT TO SCALE BIO-RETENTION FACILITY B - SCHEMATIC CROSS SECTION NOT TO SCALE24" BIO-RET SOIL MEDIA18" SUMP12"INV = 718.75 Finished Grade 6' WIDE WEIR = 724.00 (SHOWN FOR REFERENCE ELEVATION) SEE "TYPICAL BIO-RETENTION OVERFLOW WEIR DETAIL" 6" SOLID WALL PIPES (UNDERDRAIN FROM BIORETENTION FACILITIES) Geo-Textile Fabric Place Geo-Textile Fabric on top of the choker layer. Position the Filter Fabric to be centered about the Underdrain and extending 1ft. to 2 ft. beyond either side of the Underdrain. Impermeable Liner Constructed Per Criteria of Table 6, from "CSN Technical Bulletin No. 1" 12" STORAGE DEPTH 6" Perforated Underdrain (Invert = 720.00) 6' WEIR WIDTH 1.0' SECTION VIEW ALONG OVERFLOW WEIR 3:1 3:1 TOP OF BIO-RETENTION FACILITY BERM TYPICAL BIO-RETENTION OVERFLOW WEIR DETAIL NOT TO SCALE ARMOUR 6' WIDE WEIR W/ N.A.G. C350 PERM. EROSION MATTING OR APPROVED EQUAL 12' TOP WIDTH BOTTOM OF BERM = TOP OF BIO RETENTION SURFACE TOP OF BERM = +2.00' WEIR = +1.00' BOTTOM OF BERM = 0.00'U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS9500.dwg PLOTTED: 1/23/2026 3:39 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS9502 TOTAL SHEETS 42 ----  1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANBIO-RETENTION B COMPUTATIONS & DETAILS---- DRY SWALE 4: 1 S L O P E 2' BOTTOM "DRY SWALE A" TYPICAL SECTION NTS Storm Event 2 Yr. Storm 10 Yr. Storm Peak Q 0.36 cfs 0.69 cfs Flow Depth 0.10' 0.18' Velocity 0.79 fps 0.98 fps RUNOFF COMPUTATIONS DMin= 1.50'4:1 SLOPE18" BIO-RETENTION SOIL MEDIA (See Soil Media Requirements) 12" STONE RESERVOIR LAYER (Clean & Washed #57) 3" CHOKER STONE LAYER (#8 or #89 Washed Gravel) 6" RIGID SCHEDULE 40 PVC (Two 3 8" Perforations at 6" O.C.) TURF SURFACE COVER GEO-TEXTILE FABRIC Use a Non-Woven Geo-Textile Fabric with a flow rate of > 110 gal./min/s.f. (e.g., Geotex 351 or Equivalent) GEO-TEXTILE FABRIC Centered about the Underdrain and extending 1ft. to 2 ft. beyond either side of the Underdrain. DRY SWALE - LEVEL 1 CROSS SECTION NOT TO SCALE U:\Accounts\RRMMX\RRMMX24002 - MES-Expansion\DESIGN\_SHEETS\BLDG\CS9500.dwg PLOTTED: 1/23/2026 3:39 PM, BY: Christopher Mulholland PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSRRMMX24002 AS NOTED CJM 05-12-2025 DMBAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 SUBMITTED FOR REVIEW 1-23-2026 CS9503 TOTAL SHEETS 42 ----  1-23-2026  FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VIRGNIA 22604MIDDLETOWN ELEMENTARY SCHOOL190 MUSTANG LANE | MIDDLETOWN, VIRGINIA 22645 | BACK CREEK DISTRICTBUILDING EXPANSIONSITE PLANDRY SWALE A COMPUTATIONS & DETAILS----