Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SP 47-25 Application & Checklists
SITE PLAN APPLICATION - Office Use Only - Date Application Received: Application # Fees Received: Receipt #: _ Initials: 1. Project Title: N i r1 & C 'DOj Q a3 e. 2. Project Description: aC`A Y e- -Pool 11W i+,n pay q anal_ �i G-.0 Chi u —y d 0. r e Q 3. Location of Property: L��- `l 4 Vr k 0 . _ b M rn W)t, (Street Address): CZY cenvr 0bd RdCud L eT &�lr M 5 Applicant/Designer: Name:-TG,i Y)A" - Leo Telephone: fib- &(aZ - 5'792 Primary Point of Contact: TI M bthw G T01 mail: hoar ntCr-Q 130i'n*,r ICUIE. c6n-i Address: V? Cechy Cfeei- Ftrcitac �u tit, ► t> w+n�h_cs-t-Y vP� z7cek-I Property Owner (if different than above): Name: VV i Y) Ch e.S C C ZUL, Cwr er LLC Telephone: 7 63 -551 - Z Y15 ex ZZZ Address: 9 14b WrSh,kb+n PN e- &w 26q Mana ss S VA 2 6 16 cl Property Information: a. Property Identification Number(s): b. Total acreage of the parcel to be developed c. Total disturbed area of the parcel: d. Present Use(s): e. Proposed Use(s): f. Magisterial District(s) M 5S- A -- 26) �-1 I.4rl aeres 4q Acres a04 are cdi 7. Site Plan Type: a. Is this an original or new site plan? Yes:1� No: 0 b. Is this a revised site plan? Yes: II No: If yes provide all previous site plan numbers: c. Is this a minor site plan? Yes: 0 No: If yes, provide all previous site plan numbers: 8. Zoning Information: a. Current Zoning: — gencr 1 n C%S b. Was this property Rezoned? Yes: F No: c. If yes provide the rezoning number for this property: d. Are there any proffers for this property? Yes: II No: Ff e. Has an MDP been approved for this property? Yes: II No: f. If yes provide the MDP number for this property: 9. Adjoining property zoning and use: Zoning: Use: North: by-si SS South: Pr l�y1e& d oaC ' East: CAn6f4l b S West: 2 a 0 buSi V1 tj S v a) nLSs 1 have read the material included in this package and understand what is required by the Frederick County Planning Department. 1 also understand that all required material will be complete prior to the submission of my site plan. Date: 11 / 3125 *A signed Power ofAttorney form is required ifsomeone is signing on the owner(s) behalf. 0 c� co Special Limited Power of Attorney County of Frederick, Virginia Frederick Planning Website: www.fcva.us Department of Planning & Development, County of Frederick, Virginia 107 North Kent Street, Winchester, Virginia 22601 Phone (540) 665-5651 Facsimile (540) 665-6395 Know All Men By These Presents That: Winchester Daycare LLC _ Name of Property Owner/Applicant Please note: Ifthe property owner/applicant is an entity, the name of the entity should appear above. If nudtiple persons own the property or are applicants, an executed power of attorney from each owner will be needed. 8140 Ashton Avenue, Suite 207, Manassas, VA 20109 703-551-2015 exL 222 Mailing Address of Property Owner/Applicant Telephone Number as owner of, or applicant with respect to, the tract(s) or parcel(s) of land in Frederick County, Virginia, identified by following property identification numbers: 55-A-201 H do hereby make, constitute, and appoint: Painter -Lewis, P.L.C. Name of Attorney -In -Fact 817 Cedar Creek Grade, Suite 120 Winchester VA 22601 Mailing Address of Attorney -In -Fact 540-662-5792 Telephone Number to act as my true and lawful attorney -in -fact for and in my name, place, and stead, with the same full power and authority I would have if acting personally, to file and act on my behalf with respect to application with Frederick County, Virginia for the following, for the above identified property: Rezoning Subdivision Conditional Use Permit ,/ Site Plan Master Development Plan (prelim. or final) Variance or Zoning Appeal Subdivision Appeal or Waiver/Exception and, further, my attorney -in -fact shall have the authority to offer proffered conditions and to make amendments to previously approved proffered conditions except as follows: none This appointment shall expire one year from the day that it is signed, or at such sooner ti>� ' s 31 C.CV. otherwise rescind or mod I O� bNivf '• lfy G. � o. Signature "''� ' ~ '� _ : R4RAg _ Title (if si mg on behalf of an entity) hf% R-6 XT—State of /6tJc l!f} �ie 1 K� l.�t 1 t Nail wi yia V /P ,County/city of �, , ,�� .. I, C>g i L —D1 C,,-A' , a Notary Public in and for the jurisdiction aforesaid, cereit`y that the pe ho signed a oregoin L instrument personally appeared before me and has acknowledged the sa efor me, in sdi of esaid this day of - , 2001.) My Commission Expires: l 7 Notary P lic Registration Number: SITE PLAN APPLICATION CHECKLIST The checklist shown below specifies the information which is required to be submitted as part of the site plan application. The Department of Planning & Development will review the application to ensure that it is complete prior to accepting it. If any portion of the application is not complete, it will be returned to the applicant(s). ✓� (1) Digital copy of all application materials. Electronic materials may be provided on a flash drive, client FTP site, or email. • Application form with signature • Site Plan set (2) Site Plan review fee (check) made out to the Treasurer of Frederick County. �L✓ (3) Four (4) hard copies of the site plan for review with sign and seal. Three (3) full size plan set shall be provided to Planning and Development and one (1) full size plan set should be provided to VDOT (2275 Northwestern Pike Winchester, Virginia, 22603). F1 (4) Traffic Impact Analysis (if applicable, check with Planning and Development). M SITE PLAN CONTENTS CHECKLIST The Site Plan Checklist (§165-802.03), as outlined in the Zoning Ordinance and shown below, lists the information which is required to be on each site plan. Site plans that are incomplete or missing information will be returned to the applicant (s) for revision. Project Information Section (1) A title that includes the name of the proposed or existing business and a subtitle which describes the proposed development. �^ (2) The name, address, and phone number of the land owner, developer, and designer. (3) The Frederick County Property Identification Number (PIN) of all lots included on the site plan. L� l (4) The number and type of dwelling units included on the site plan for residential uses. (5) The total land area and total developed land area of all lots included on the site plan. F(6) A detailed description of the proposed use or uses of the development, as well as a description of the existing use or uses. V(7) A reference to any other site plan, master development plan approved by the county for the site. (8) The date the site plan was prepared and a list of all revisions made, including the date and a description of why the site plan was revised. �.. _ (9) A table of contents including all pages of the site plan. ✓� (10) A list of all proposed utility providers, with their address and phone number. n(11) A location map showing the location of the site, along with the location of streets, roads and land uses within five hundred (500) feet of the property. (12) A statement listing all requirements and conditions placed on the land included in the site plan resulting from approval of conditional zoning or a conditional use permit. ✓� (13) A description of setbacks or conditions placed on the site as a result of an approved variance. (14) The name of the Magisterial District the property is located within. 11 Calculations Section (15) Calculations showing the Floor Area Ration (FAR) of the site, including the maximum allowed FAR, total ground floor area, total floor area, and total lot area. W(16) Calculations showing the total number of required and proposed parking spaces, including the total number of existing and proposed spaces. (17) Calculations showing the total number of required handicap spaces, including the total number of existing and proposed spaces. n_ (18) Calculations showing the total number of required loading spaces, including the total number of existing and proposed spaces. (19) Calculations showing the total number of required perimeter and interior trees required, including the number of provided trees. W(20) Calculations showing the percentage of the property that will be landscaped and the percentage of woodlands disturbed. Site Plan & Details Section (21) The location of all adjoining lots with the owner's name, specific use, zoning, and zoning boundaries shown. (22) The location of all existing or planned right-of-ways and easements that are located on or adjoin the property, with street names, widths, and speed limits shown. (23) All nearby entrances that are within two hundred (200) feet of any existing or proposed entrances to the site. �F&/]_ (24) All existing and proposed driveways, parking and loading spaces, parking lots and a description of surfacing material and construction details to be used. The size and angle of parking spaces, aisles, maneuvering areas, and loading spaces shall be shown. �✓ _ (25) A North arrow. F(26) A graphic scale and statement of scale. (27) A legend describing all symbols and other features that need description. ✓� (28) A boundary survey of the entire parcel and all lots included with distances described at least to the nearest hundredth of a foot. (29) The present zoning of all portions of the site, with the location of zoning boundaries. Fy l (30) The location of all existing and proposed structures, with the height, specific use, 12 ground floor area, and total floor area labeled. (31) The location of all existing and proposed outdoor uses, with the height, specific use, and land area labeled. (32) Existing topographic contour lines at intervals acceptable to the Zoning Administrator. Proposed finished grades shall be shown by contour. FV] (33) The location of the front, side, and rear yard setback lines required by the applicable zoning district. (34) The location and boundaries of existing environmental features, including streams, floodplains, lakes and ponds, wetlands, natural stormwater retention areas, steep slopes, and woodlands. ✓� (35) The location of outdoor trash receptacles with details for all required screening elements. l�! (36) A Photometric Plan per §165-201.07. (37) The location, dimensions, and height of all signs. (38) The location of required buffers, landscaping buffers, and landscaped screens, including examples, typical cross sections or diagrams of screening to be used. The location and dimensions of required fencing, berms, and similar features shall be specified. (39) The location of recreational areas and common open space. (40) The location of all proposed landscaping with a legend. The caliper, scientific name, and common name of all deciduous trees. The height at planting, scientific name, and common name of all evergreen trees and shrubs. Fy]�— (41) The height at planting, caliper, scientific name, and common name shall be provided for all proposed trees. The height at planting, scientific name and common name shall be provided for all shrubs. (42) The location of sidewalks and walkways, including all sidewalks or bicycle paths required along any road right of way. (43) The location and width of proposed easements and dedications. (44) A stormwater management plan describing the location of all stormwater management facilities with design calculations and details. (45) A soil erosion and sedimentation plan describing methods to be used. LV(46) The location and size of sewer and water mains and laterals serving the site. 13 (47) Facilities necessary to meet the requirements of the Fire Code. ✓-1 (48) A signed seal of the certified Virginia land surveyor, architect, or engineer who prepared the plan. The seal and signature of the engineer, surveyor or architect shall be on each sheet of the site plan. (49) A space labeled "Approved by the Frederick County Zoning Administrator" for the signature of the Zoning Administrator, approval date, and a statement that reads "site plan valid for five (5) years from approval date." I� (50) All requirements specified elsewhere in the County Code, including but not limited to the Subdivision Ordinance. 14 Review Checklist Frederick County, Virginia Department of Public Works e Subdivision/Site Plan Name: W iy)C1n e ©au crtir e_ Engineer/Surveyor Name: R% ritCx _ 1-r_,IA,tS.'.l.- C Engineer/Surveyor Phone: St4b` (o(a2- Tax Map (PIN): k - 20l H Note: Provide sheet number(s) for each item or indicate if not applicable. Requirements Sheet NIA FC Check Provide a note pertaining to temporary and permanent stabilization of denuded OG areas. Provide a note pertaining to stabilization requirements for soil stockpiles. Provide a note stating that vegetative stabilization shall be uniform, mature G• dG enough to survive and adequate to inhibit erosion. Provide sediment trapping facilities as the first phase of land disturbing activity. Provide a note requiring that dams, dikes and diversions be stabilized (1-0& immediately after construction. Sediment traps and basins shall be installed if necessary and in the correct location. Basins shall maintain structural integrity during 100-year 24 hour storm 6,0& event. (§79-3.A.1 Frederick County Code). C0(0 Cut and fill slopes shall be adequately stabilized. Fill slopes steeper than 3:1 will require a slope stability analysis and maintenance plan. - //� ��--��ll� V•"6 Provide adequate temporary or permanent channel, flume or slope drain for all concentrated runoff down cut or fill slopes. G v�' Provide adequate drainage or other protection whenever water seeps from a slope face. Provide adequate inlet protection for all operational storm sewer inlets. L,p� Provide adequate channel protection for open conveyance and receiving channel, provide adequate outlet protection for pipes and channels. Provide measures to minimize channel damage when conducting in -stream/^ construction. Install temporary stream crossings of non -erodible material C_&G All applicable federal, state and local regulations pertaining to working in or crossing live watercourses shall be met - all applicable permits shall be Cob submitted with Land Disturbance application (§79-3.A.2 Frederick County Code). Provide a note stating that the bed and banks of a watercourse shall be stabilized immediately after work in the watercourse is completed. Provide appropriate notes regarding trenching practices in accordance with G'�� 4VAC50-30-40 subsection 16. Requirements Sheet NIA FC Check (� Provide a note requiring cleaning/removal of any sediment on public or private roadways. Provide a note requiring that all temporary controls be removed within 30-days once no longer needed; trapped sediment must be removed and stabilized. Provide adequate protection from erosion and sediment deposition for downstream properties and waterways. C. i 1 Demonstrate that concentrated stormwater runoff leaving the site discharges directly into an adequate natural or manmade channel. Demonstrate that two (2)-year runoff from the site does not overtop banks of natural channels and does not cause erosion. Demonstrate that discharge into the previously constructed man-made channels are not overtopped by a ten (10)-year storm and the two (2)-year storm does not C , cause erosion C Demonstrate that closed storm sewer systems contain the ten (10)-year storm. Provide calculations and show ten (10)-year HGL in the storm sewer profiles. If offsite improvements are proposed, provide evidence of obtained easements, etc. IV t., to Provide an analysis of the existing and ultimate characteristics of the watershed. G'v Provide responsible party and maintenance plan for the proposed detention facilities to include access, what is to be maintained?, how often?, who pays? Provide energy dissipaters at the outfall of all detention facilities. IvJ� Provide calculations demonstrating that onsite ditches are adequate. P14 All sheet flow leaving the site shall be at or below pre -developed rates or it must /� be diverted to an adequate channel, pipe system or detention facility. All calculations and assumptions shall pertain to the entire development and its ultimate build -out. C—07 V All measures utilized shall minimize the impact on waters of the State. G .06 Project description - Describe the nature and purpose of the land disturbing activity and area (acres) to be disturbed. Existing Site Conditions - Provide a description of the existing topography, vegetation and drainage. Adjacent Areas - Provide a description of neighboring areas such as streams, lakes, residential areas, roads, etc., which might be affected by the land disturbance. 0 Off -site areas - Describe any off -site land -disturbing activities that will occur. • v� Soils - Provide a brief description of the soils on the site giving such information as soil name, mapping unit, erodibility, permeability, depth, texture and soil structure. Geology - Provide a brief description of the geology on the site related to construction; i.e. methods of removal, use as engineered fills, Karst potential, etc. Requirements Sheet NIA FC Check Critical areas - Provide a description of areas on the site which have potentially serious erosion problems. C E&S control measures - Provide a description of the methods which will be used to control erosion and sedimentation on the site. C .O& Permanent stabilization - Provide a brief description, including specifications, of how the site will be stabilized after construction is completed. C.O& Stormwater runoff narrative - Will the development of the site cause an increase in peak runoff rates? Will it cause flooding? Describe the strategy to control stormwater runoff. 0t_1 Calculations - detailed calculations for the design of temporary sediment basins, permanent stormwater detention basins, diversions, channels, etc. Include calculations for pre- and post -development runoff C •07 Provide a vicinity map. C-- V I Provide a North arrow and scale on all plan sheets. A (L Delineate the proposed limits of clearing and grading. C•Vy Show and label existing contours. L oq Show and label final contours. •OLI Show existing vegetation. C .J'j Show boundaries of different soil types. C-0 G Show existing drainage patterns including the acreage of each drainage area. C, to Label areas with potentially serious erosion problems. 4M Show and label all proposed site improvements. a ,O Label all storm pipe systems on grading plan sheets (pipe size, material, structure numbers). C-.ny Show elevations for the proposed basement floor, first floor and garage slab for all buildings and finished grade elevations at building corners. •O Show location of all retaining walls with elevations for proposed top and bottom of walls. Conveyance system protection and flood protection analysis provided at every discharge point of concentrated flow originating from site improvements. Show location of all erosion and sediment control measures using VESCH standard symbols. C Show all off -site land disturbing activities and erosion and sediment control measures. Provide letter of permission or show temporary construction easements as necessary. A) Provide stage -storage, stage -discharge and routing data for all SWM/BMP ponds. Af/1A Provide VRRM spreadsheet data. L. V 7 Requirements Sheet NIA FC Check Drainage area map showing individual and cumulative drainage area contributing to each point of concentration. Provide a maintenance schedule including regular inspection and repair of erosion and sediment control measures. Provide the Responsible Land Disturber signature block on the plans. Provide a seeding schedule in accordance with VESCH standard 3.31 and 3.32. e.DL Provide a 20-foot drainage easement for all concentrated flows within on- or off- site residential lots. Provide a minimum of 2% slope on grass channels. If less than 2%, provide an alternative design. t! qq M Any area in which drainage collects from more than three (3) lots shall be placed within a platted drainage easement. All silt fence shall be wire reinforced. C (� Drop Inlets in areas accessible to the public will require an appropriately sized grate opening. Please specify the grate type in the plans. Ensure that the backwater condition for the post -developed 100-year storm does not impact adjacent properties. Show the location and extent of the overland relief flow paths provided for SWM conditions and to clear buildings for the 100-year storm. l Provide the dewatering structure details for the proposed sediment basins. The details shall include elevations, type of structures, pipe sizes, etc. �(p 2 Z(, - ngineer's Signature 11 /3/2s Date REVIEW CHECKLIST This checklist is to be completed by the Design Professional and submitted with the Site Plan. FREDERICK WATER Subdivision/Site Plan Name: Design Professional Name: Design Professional Phone: 54 d - U (,Z- S-1 q Z - ---------------------------------------------------------------------------------- Tax Map (PIN): ` a S -- P _ 26 - ------------------------------------------------------------ Submission Date: Submission Number: -------------------------------------------------------------------------------------------- o Review Key N a� ✓ O.K. O Incomplete REQUIREMENTS o 3 N Not Applicable X Unacceptable 5 a� N fN GENERAL NOTES 1 Owner's and Developer's contact information V G p) 2 Magisterial district, tax map; and address if applicable j/ C -v1 3 Utility contact information J p z 4 North arrow on all plan sheets 5 Scale references on all plan sheets 6 Current FW Standards and Specifications have been reviewed for compliance at www.FW-water.com 7 Current FW construction notes are on plans C .d 2, 8 All existing easements are shown including deed book & page or instrument number 9 Vicinity map ✓ , D 10 General layout sheet ✓ t✓ 11 Current existing water and sanitary sewer infrastructure '� L is shown and described •03 12 Required onsite FW easements are identified 13 Required off site FW easements are identified 14 Note has been added to landscape drawings that no Q V trees or shrubs shall be placed on FW easements 15 Project Acceptance Requirements per FW standards (page 4) have been considered in project phasing 16 Existing site conditions are shown and labeled ie. ex. ✓ v 3 structures, utilities etc. Master development plan reviewed for compliance and 17 MDP #, date included. Any variiance from MDP water or IV sewer re uirements is explained Revised 1/4/18 Frederick Water Plan Review Checklist Page 1 of 4 18 Proffer statement reviewed for compliance and copy included 19 Exceptions to FW requirements are described 20 Length of water and sewer lines on private property to be owned by_ FW ke t to minimum 21 Lot numbers, building numbers and street names are shown on all sheets All plan sheets have been reconciled to reflect the 22 same information v Existing FW infrastucture requiring field adjustment 23 where grade changes occur has been shown Existing FW facilities to be removed or abandoned are 24 noted accordingly. Significant items, fire hydrants, N valves etc. are noted to be furnished to FW inspector Ownership of existing and proposed, water and sanitary 25 sewer is labeled 26 Continutity of service to adjacent parcels has been ✓ considered and easements provided 27 FW easements are exclusive. Crossings permitted only as necessary, 28 Street ownership (VDOT or private) is shown 29 Water and sanitary sewer usage form is completed WATER 30 Project water system has been modeled f 31 Air release has been evaluated and shown FW's water infrastructure has been evaluated and can 32 meet project demands 33 Water meter size(s) are shown ✓ Fire line(s) to building show gate valve 10'-20' off 34 building with ownership line, valve is the end of FW r ownership 35 Double detector size and location is shown 36 Water segments are labeled on plan and profile ✓ Sanitary sewer crossings are shown under water lines 37 with min. 18" separation ✓ 38 Sanitary lateral crossings have lot number and N elevation shown on profile 39 All crossings are labeled including min. 18" separation Connection to exsiting lines are labeled and include 40 party responsible for field connection Special conditions; service disruption, by pass piping, 41 etc. is clearly detailed Existing and proposed line diameters, pipe types etc. 42 are shown 43 Water lines shall be CL 52 DIP Water lines under permeable pavers should be 44 minimized Bollards around fire hydrants in truck and other 45 vulnerable areas are shown N 46 Applicable FW detail drawings are included 47 Restrained joints in fill areas and 20' onto original N round are reflected Revised 1/4/18 Frederick Water Plan Review Checklist Page 2 of 4 48 Existing FW laterals, services, main stubs etc unutilized are shown with details for disconnection and removal _ 49 Protectus 3 meter including size, is shown for private 7 underground fire lines /V 50 Fire lines are shown as CL 52 DIP and restrained 51 Pipe types are shown on plan and profile for all segments 52 Valves are shown on all branches of tees, crosses, w es etc. 53 Minumum 25' pre blast is shown for main line stubs 54 Air release and vacuum breaker valves have been evaluated and shown N 55 Appropriate FW detail drawings are included G l2 Virginia Department of Health's Project Summary 56 Report is completed and included, see http://www.vdh.virginia.govlcontent/uploads/sites/14/20 16/04/General-Permit-Project-Summary-Report. pdf SANITARY SEWED 57 Project sanitary sewer system has been modeled v/ 58 FW's sanitary sewer infrastructure has been evaluated ✓ and can meet project demands 59 Manhole rim elevations are shown 60 Sewer segments are labeled on plan and profile ✓ 61 Water line crossings are shown above sewer min. 18" separation 62 All crossings are labeled including min. 18" separation 63 Connection points are labeled and identify party performing connection 64 Special conditions; service disruption, by pass piping, A �V etc. is clear) detailed 65 Line diameters, pipe types etc. are shown 66 Sewer lines under permeable pavers should be minimized 67 Applicable FW detail drawings are included V/ C. Z Existing FW laterals, services, main stubs etc unutilized 68 are shown with details for disconnection and removal 69 Restrained joints in fill areas and 20' onto original 4/1 round are reflected 70 Drop connections are noted on plans and profiles /% 71 Multiple inside drop connections into same manhole N have been evaluated and larger manhole is identified 72 Manholes larger than 4' in diameter are labeled f 73 Deep sewer laterals are noted on plans and profiles N 74 Pipe types are shown on plan and profile for all ` segments V 75 Minumum 25' pre blast is shown for main line stubs /U Revised 1/4/18 Frederick Water Plan Review Checklist Page 3 of 4 76 Air release and vacuum breaker valves have been evaluated and shown 77 Appropriate FW detail drawings are included SANITARY SEWER PUMP STADONS 78 Show all proposed site improvements. 79 Pump station wet well accessible by vactor truck N 80 Personnel door accessible to full size pick up truck suction lift pumps only) N 81 Show and label existing contours. 82 Show and label final contours. 83 Show proposed utilities, including electrical, telephone services information 84 Show transformer and generator location and dimensions 85 Provide 100-year floodplain elevation and note on PS Ian 86 Fence is shown on property line 87 Gently sloping minimum 3' gravel outside fence perimeter 88 Surface water is directed away from pump station lot fU 89 Paving and stone areas are labeled 90 Gate size is shown and post is min. 1' off pavement J 91 Access road provides heavy truck access and slopes no areater than 10 % , l N 92 Station information sheets are complete including interim and buildout as applicable 93 Appropriate FW detail drawings are included 94 95 96 97 98 99 100 101 102 103 104 105 Revised 1/4118 Frederick Water Plan Review Checklist Page 4 of 4