HomeMy WebLinkAbout45-25 SiteU:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS0000.dwg PLOTTED: 9/30/2025 12:44 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKLOCATION MAP
Scale: 1" = 2000'
CALL 1-800-552-7001
CALL BEFORE YOU DIG
ALWAYS CALL 811 BEFORE YOU DIG IN VIRGINIA
SECTION 56-265.17 REQUIRES THREE WORKING DAYS
NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR
BLAST VIRGINIA UTILITY PROTECTION SERVICE, INC.
TICKET NUMBER(S):
PREPARED BY:
PENNONI ASSOCIATES INC.
117 East Piccadilly Street
Winchester, VA 22601
T 540.667.2139
F 540.665.0493 PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NORTHNOT FOR BID OR CONSTRUCTION
PREPARED FOR:
OWNER/DEVELOPER
FISHER SCIENTIFIC COMPANY, LLC
300 INDUSTRY DRIVE
PITTSBURG, PA 15275
(724) 517-1500
THERMO FISHER PARKING EXPANSION
SITE PLAN
SITE PLAN #___-___
BACK CREEK DISTRICT - FREDERICK COUNTY, VA
ORIG SUBMISSION DATE: TBD
REVISED SUBMISSION DATE: TBD
FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTCOVER SHEETCS0000
SHEET 1 OF 19 2025-09-08 RESPONSIBLE LAND DISTURBER
THE RESPONSIBLE LAND DISTURBER IS THAT PARTY RESPONSIBLE FOR CARRYING
OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS.
NAME:_____________________________________________________
CERTIFICATION #:___________________________________________
DATE: _____________________________________________________
APPROVED BY FREDERICK COUNTY PLANNING DEPARTMENT
APPROVAL VALID FOR _____ YEARS.
________________________________________________________________________________
APPROVED BY DATE
SITE
LOCAL UTILITIES IN FREDERICK COUNTY
RAPPAHANNOCK ELECTRIC CO-OP
137 KELLEY COURT
FRONT ROYAL, VIRGINIA 22630
(540) 662-2037
VERIZON
404 HILLANDALE LANE
WINCHESTER, VIRGINIA 22602
(540) 665-3156
COMCAST COMMUNICATIONS
195 RAINVILLE ROAD
WINCHESTER, VIRGINIA 22602
(540) 504-0942
WASHINGTON GAS
350 HILLANDALE LN.
WINCHESTER, VIRGINIA 22602
(540) 868-7913
FREDERICK WATER
315 TASKER ROAD
STEPHENS CITY, VIRGINIA 22655
(540) 868-1061
Sheet List Table
Page Number Sheet Number Sheet Title
1 CS0000 COVER SHEET
2 CS0001 GENERAL NOTES & LEGEND
3 CS1000 EXISTING CONDITIONS
4 CS1100 SOILS MAP
5 CS2000 EROSION & SEDIMENT CONTROL NARRATIVE
6 CS2100 DEMO PLAN AND EROSION & SEDIMENT CONTROL PLAN - PHASE I
7 CS2200 EROSION & SEDIMENT CONTROL PLAN - PHASE II
8 CS2500 EROSION & SEDIMENT CONTROL DETAILS
9 CS4000 GEOMETRIC PLAN
10 CS4500 SITE DETAILS
11 CS6000 GRADING & DRAINAGE PLAN
12 CS6100 STORM SEWER PROFILES & CALCULATIONS
13 CS6500 STORM SEWER DETAILS
14 CS7000 LANDSCAPING PLAN, CALCULATIONS & DETAILS
15 CS8000 FIRE LANE MARKING & SIGNAGE PLAN
16 CS8100 PHOTOMETRIC PLAN
17 CS9100 SWM NARRATIVE, COMPLIANCE, & COMPUTATIONS
18 CS9200 PRE-DEVELOPMENT DRAINAGE MAP
19 CS9300 POST-DEVELOPMENT DRAINAGE MAP
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS0001.dwg PLOTTED: 9/30/2025 12:45 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493 NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTGENERAL NOTES & LEGENDCS0001 2025-09-08 SHEET 2 OF 19
CG-6
CONCRETE SIDEWALK
LIMITS OF CLEARING AND GRADING
STORM SEWER
WATERLINE
CONTOURS
UNDERGROUND ELECTRIC SERVICE
SANITARY SEWER WITH MANHOLE
PROPERTY LINE
UTILITY POLE
SIGN POST
744
LEGEND
FIRE HYDRANT ASSEMBLY
GAS LINE
HY D
SF SQUARE FEET
SEC SECTION
RTE ROUTE
ROW RIGHT-OF-WAY
FT FEET
POLYVINYL CHLORIDE
REINFORCED CONCRETE PIPE
VIRGINIA DEPARTMENT OF
WELDED WIRE MESH
POINT OF VERTICAL INTERSECTION
W/
FIRE HYDRANTF.H.
WV WATER VALVE
BEST MANAGEMENT PRACTICE
BEGIN VERTICAL CURVE STATION
BEGIN VERTICAL CURVE ELEVATION
END VERTICAL CURVE STATION
END VERTICAL CURVE ELEVATION
DROP INLET
DIAMETER
DUCTILE IRON PIPE
EROSION CONTROL
ELEVATION
END SECTION
FINISHED FLOOR ELEVATION
ELEV
F.F.E.
EVCS
EX
EVCE
ES
EXISTING
DIP
EA
EC
DIA
DI
EACH
BENCHMARK
CLEANOUT
CONCRETECONC
CL
CO
BVCS
BVCE
CLASS
BLDG
B.M.
BMP
BUILDING
STR
VERT
WWM
TYP
VDOT
RCP
SHT
STM
PVC
PVI
STRUCTURE
TYPICAL
VERTICAL
WITH
SHEET
STEAM
HORIZ
MECH
MIN
MSE
INV
MAX
G.V.
HORIZONTAL
INVERT
MAXIMUM
MECHANICAL
MINIMUM
MECHANICALLY STABILIZED EARTH
GATE VALVE
AREA DRAINAD
TRENCH DRAINTD
LIMITS OF DISTURBANCELOD
APPX.APPROXIMATELY
OVERHEAD ELECTRICOHE
UNDERGROUND ELECTRICUGE
UGT UNDERGROUND TELEPHONE
TELCO TELECOMMUNICATIONS
WWF WELDED WIRE FABRIC
CAST IRONCI
STAINLESS STEELSS
TREE PROTECTIONTP
NORTH BOUND LANENBL
SOUTH BOUND LANESBL
BW BOTTOM OF WALL
TOP OF WALLTW
ON CENTER EACH WAY
ON CENTEROC
OCEW
PROP PROPOSED
DIAMETERØ
MANHOLEMH
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
CWR
CWS CHILLED WATER SUPPLY
CHILLED WATER RETURN
MECHANICAL, ELECTRICAL, PLUMBINGMEP
ABBREVIATIONS
MLP METAL LIGHT POLE
MSP METAL SIGN POLE
F.H. ASSY FIRE HYDRANT ASSEMBLY
HANDICAP PARKINGHCP
BUILDING RESTRICTION LINEBRL
ASPHALT PAVEMENT
W
S
G
E
IV IRRIGATION VALVE
NO PARKINGNP
GENERAL CONSTRUCTION NOTES:
1.THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR AND EQUIPMENT AND PERFORM ALL WORK
INCLUDING RESTORATION FOR THE COMPLETED INSTALLATION OF THE UTILITY SYSTEMS AND ALL OTHER
IMPROVEMENTS SHOWN OR IMPLIED AS NECESSARY FOR THE COMPLETED FACILITY READY FOR USE.
UNLESS OTHERWISE NOTED, SPECIFICATIONS FOR ALL WORK TO BE IN ACCORDANCE WITH APPLICABLE
STANDARDS AND CONSTRUCTION SPECIFICATIONS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION,
FREDERICK COUNTY PUBLIC UTILITIES AND ENVIRONMENTAL MAINTENANCE AND THE CONTRACT
DOCUMENTS.
2.THE ENGINEER HAS ATTEMPTED TO LOCATE EXISTING SUBSURFACE UTILITIES; HOWEVER, SUCH MAY
EXIST THAT ARE NOT SHOWN. THE CONTRACTOR SHALL EXERCISE CARE IN THIS WORK SO AS TO AVOID
DAMAGE TO ANY UTILITIES. ANY DAMAGE SHALL BE THE CONTRACTOR'S RESPONSIBILITY. THE CONTRACTOR
SHALL NOTIFY ALL UTILITY COMPANIES 72 HOURS PRIOR TO CONSTRUCTION. CALL "MISS UTILITY" 811.
3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION STAKEOUT. ALL DIMENSIONS,
ELEVATIONS AND LOCATIONS SHALL BE VERIFIED IN THE FIELD BY EACH CONTRACTOR PRIOR TO BEGINNING
THE WORK. THE COUNTY ENVIRONMENTAL MAINTENANCE ENGINEER WILL APPROVE ALL CUT SHEETS.
4.ANY UNUSUAL SUBSURFACE CONDITIONS ENCOUNTERED DURING THE COURSE OF THE WORK SHALL
BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER AND/OR THE OWNER.
5.ALL GRADING FOR IMPROVEMENTS TO BE CONFINED TO THE PROJECT AREA. ANY WORK PERFORMED
OFFSITE IS THE CONTRACTOR'S RESPONSIBILITY.
6.CONTRACTOR TO OBTAIN, AT HIS EXPENSE, ALL PERMITS REQUIRED OF THIS WORK AND SHALL
FAITHFULLY ADHERE TO THE PERMIT CONDITIONS IMPOSED.
7.ALL UNPAVED AREAS OF THE SITE WHICH ARE DISTURBED BY THIS CONSTRUCTION SHALL BE
PROVIDED WITH 4" TOPSOIL, FERTILIZED, SEEDED, COMPACTED AND MULCHED. SEED BED TO BE WATERED
AND CARED FOR AS NECESSARY TO PROVIDE A GOOD LAWN QUALITY GRASS COVER. AREAS NOT GRADED
SHALL BE DISCED, LEVELED AND SEEDED TO ACHIEVE LAWN CONDITIONS.
8.WATER AND SEWER LINES ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THESE PLANS AND
SPECIFICATIONS AND SHALL ADDITIONALLY MEET ALL REQUIREMENTS OF FREDERICK COUNTY. THE
CONTRACTOR SHALL COORDINATE WITH THIS AGENCY AND ARRANGE FOR INSPECTION AS NECESSARY.
EXACT LOCATIONS FOR WATER AND SEWER SERVICES TO BE DIRECTED BY THE FREDERICK COUNTY
INSPECTOR IN THE FIELD. CONTRACTOR TO PROVIDE ASSISTANCE AS THE INSPECTOR MAY REQUIRE.
8A. CONTRACTOR SHALL PROVIDE THE PUBLIC UTILITIES DEPT. 24 HOUR NOTICE PRIOR TO TAPPING
EXISTING WATER MAINS.
8B.PROPOSED WATER MAINS WILL REQUIRE TESTING IN ACCORDANCE WITH PUBLIC UTILITY
SPECIFICATIONS. THE CONTRACTOR SHALL SCHEDULE THESE TESTS AND PROVIDE ASSISTANCE AS
NECESSARY.
8C. SHOULD MAINTENANCE OF WATER OR SEWER LINES WITHIN EXISTING EASEMENTS REQUIRE
DISTURBANCE OF PROPOSED IMPROVEMENTS, THE OWNER IS RESPONSIBLE FOR REPAIR OF THOSE
ITEMS.
9.TEMPORARY TERMINATION OF SEWER LINES SHALL BE PLUGGED WATERTIGHT. THE END OF THE LINE
SHALL BE MARKED WITH A TREATED 2 INCH X 4 INCH POST EXTENDING AT LEAST 18 INCHES ABOVE THE
GROUND. THE TOP 6 INCHES SHALL BE PAINTED GREEN, AND THE CUT DEPTH TO THE LINE INVERT SHALL BE
SHOWN.
DESIGN FEATURES RELATING TO CONSTRUCTION OR TO REGULATION, CONTROL AND SAFETY OF TRAFFIC
MAY BE SUBJECT TO CHANGE AS DEEMED NECESSARY BY FREDERICK COUNTY.
10.AFTER REMOVAL OF ALL TOPSOIL, THE SUBGRADE SHOULD BE PROOF ROLLED WITH APPROVED
CONSTRUCTION EQUIPMENT PRIOR TO FILL REPLACEMENT. ALL SUBGRADE AREAS SHALL BE STABLE PRIOR
TO FILL PLACEMENT. ALL FILL AND BASE MATERIAL SHALL BE COMPACTED TO 100% OF THE MAXIMUM DRY
DENSITY AS DETERMINED BY ASTM D 698 (STANDARD PROCTOR). LANDSCAPED AREAS SHALL BE
COMPACTED TO 90% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY THE SAME STANDARD.
COMPACTION TESTING SHALL BE PERFORMED BY A QUALIFIED GEOTECHNICAL ENGINEER REGISTERED IN
THE COMMONWEALTH OF VIRGINIA OR A QUALIFIED REPRESENTATIVE UNDER DIRECT SUPERVISION OF THE
ENGINEER.
11.ACCESS FOR EMERGENCY VEHICLES MUST BE MAINTAINED AT ALL TIMES. TEMPORARY STREET SIGNS
MUST BE POSTED AS CONSTRUCTION BEGINS. ACCESS TO FIRE HYDRANTS IS NOT TO BE IMPEDED AT ANY
TIME BY CONSTRUCTION MATERIALS, PARKED CARS ETC.
12.MANHOLE RIMS, VALVE BOXES, ETC. TO BE ADJUSTED TO MATCH PROPOSED ELEVATIONS SHOWN IN
THESE PLANS.
13.IF BLASTING IS REQUIRED THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING THE NECESSARY FIRE
DEPARTMENT PERMITS.
FREDERICK COUNTY PUBLIC UTILITIES:
1.THE CONTRACTOR SHALL ADHERE TO THE STANDARDS AND SPECIFICATIONS IN EFFECT AT THE TIME
OF CONSTRUCTION.
2.THE CONTRACTOR SHALL COORDINATE WITH AND ARRANGE FOR INSPECTION BY PUBLIC UTILITIES.
3.THE CONTRACTOR SHALL TIE-IN A NEW SEWER LINE TO AN EXISTING MANHOLE BY CORE DRILLING THE
MANHOLE.
4.WHEN AN EXISTING WATER (OR FORCED SEWER) MAIN IS TAPPED FOR THE INSTALLATION OF A NEW
LINE:
4.a.CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIAL.
4.b.THE CONTRACTOR MUST:
4.b.1.MAKE APPLICATION AND PAY DEPOSIT
4.b.2.MARK THE TAP LOCATION
4.b.3.COORDINATE INSTALLATION WITH THE ENGINEERING-ASSISTANT.
5.EXACT LOCATIONS OF WATER AND SEWER SERVICES ON NEW LINES ARE TO BE COORDINATED WITH
THE INSPECTOR.
6.PUBLIC UTILITIES SHALL FURNISH AND INSTALL ALL WATER METERS THROUGH 2" IN SIZE. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO HAVE THE METER BOX ASSEMBLY INSTALLED CORRECTLY. BEFORE A
PERMANENT METER IS INSTALLED:
6.a.THE METER BOX, WITH ITS FRAME AND COVER, MUST BE PROPERLY ALIGNED WITH THE
COPPERSETTER.
6.b.THE FRAME AND COVER SHALL BE SET TO FINAL GRADE.
6.c.THE DISTANCE BETWEEN THE TOP OF THE COVER AND THE COPPERSETTER SHALL BE 24 INCHES.
6.d.ALL COMPONENTS OF THE METER BOX ASSEMBLY SHALL BE IN PROPER WORKING ORDER.
7.FOR WATER AND SEWER SERVICES THAT CONNECT TO EXISTING LINES:
7.a.THE LOCATION OF THE SERVICE LATERAL IS TO BE COORDINATED WITH THE ENGINEERING
ASSISTANT.
7.b.SERVICE TAPS MAY BE MADE BEFORE PAYMENT OF FEES; HOWEVER, TAP FEES MUST BE PAID
PRIOR TO SETTING METERS OR ISSUANCE OF BUILDING PERMITS.
7.c.PROVISION AND INSTALLATION OF METERS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION
OF THE CITY'S PUBLIC SERVICES STANDARDS MANUAL.
7.d.CONTRACTOR SHALL MAKE ALL TAPS AND SERVICE LINE INSTALLATIONS. THE CONTRACTOR
SHALL FURNISH AND INSTALL THE METER VAULT ASSEMBLY. PUBLIC UTILITIES WILL INSTALL THE
METER.
7.e.CONTRACTOR WILL INSTALL ALL SEWER LATERALS.
8.ANY WATER SERVICE LINE MUST HAVE A BACKFLOW PREVENTION ASSEMBLY (DETECTOR DOUBLE
CHECK VALVE OR RPZ, AS REQUIRED). THE ASSEMBLY MUST MEET ASSE STANDARD NO. 1015 OR 1013.
9.ALL FIRE LINES SHALL HAVE A BACKFLOW PREVENTION ASSEMBLY (DETECTOR DOUBLE CHECK VALVE
OR RPZ, AS REQUIRED). THE ASSEMBLY SHALL MEET ASSE STANDARD NO. 1048 OR 1047.
PUBLIC UTILITIES TO REVIEW THE MECHANICAL PLAN(S) FOR DESIGN AND MATERIAL APPROVAL OF: 1) THE
DOMESTIC WATER METER AND ITS BACKFLOW PREVENTION DEVICE, AND/OR 2) THE FIRE SERVICE LINE'S
BACKFLOW PREVENTION DEVICE
FREDERICK COUNTY STORMWATER COLLECTION
SYSTEMS MATERIAL REQUIREMENTS
1.CONCRETE PIPE
a.CIRCULAR REINFORCED CONCRETE CULVERT AND STORM SEWER PIPE SHALL BE IN ACCORDANCE WITH ASTM C76 AND BE
CLASS III MINIMUM.
b.ELLIPTICAL REINFORCED CONCRETE CULVERT AND STORM SEWER PIPE SHALL BE IN ACCORDANCE WITH ASTM C507.
c.GASKETED JOINTS SHALL BE BELL AND SPIGOT WITH RUBBER GASKET SEAL IN ACCORDANCE WITH ASTM C443. TONGUE AND
GROOVE JOINTS SHALL BE SEALED WITH MORTAR OR PRE-FORMED FLEXIBLE SEALANT PER ASTM C990, OR OTHER SUITABLE
SEALANT.
2.CORRUGATED PLASTIC PIPE
a.PIPE SHALL BE IN ACCORDANCE WITH AASHTO M294 OR ASTM F2306.
b.PIPE SHALL BE JOINED USING A BELL AND SPIGOT JOINT MEETING AASHTO M252,
AASHTO M294, OR ASTM F2306. THE JOINT SHALL BE SOIL-TIGHT AND GASKETS, WHEN APPLICABLE, SHALL MEET THE
REQUIREMENTS OF ASTM F477. GASKETS SHALL BE INSTALLED BY THE PIPE MANUFACTURER AND COVERED WITH A REMOVABLE
WRAP TO ENSURE THE GASKET IS FREE FROM DEBRIS. A JOINT LUBRICANT SUPPLIED BY THE MANUFACTURER SHALL BE USED ON
THE GASKET AND BELL DURING ASSEMBLY.
c.FITTINGS SHALL CONFORM TO AASHTO M252, AASHTO M294 OR ASTM F2306.
BELL AND SPIGOT CONNECTIONS SHALL UTILIZE A SPUN-ON OR WELDED BELL AND VALLEY OR SADDLE GASKET MEETING THE
SOIL-TIGHT JOINT PERFORMANCE REQUIREMENTS OF AASHTO M252, AASHTO M294 OR ASTM F2306.
d.ALL INSTALLATION OF CORRUGATED PLASTIC PIPE SHALL BE PER THE MANUFACTURER’S SPECIFICATIONS.
3.DROP INLETS
a.STANDARD DROP INLETS SHALL BE PER THE VDOT SPECIFICATIONS.
b.FOR DROP INLETS IN SHALLOW CONDITIONS, STRUCTURES SHALL BE CONSISTENT WITH STANDARD DETAIL SD-04 OR SHALL
BE A PRECAST OR CAST-IN-PLACE CONCRETE BOX WITH A TOP CONSISTENT WITH STANDARD DETAIL SD-05.
c.FOR DROP INLETS REQUIRING A MANHOLE FRAME AND COVER FOR ACCESS, THE MANHOLE FRAME AND COVER SHALL BE AS
MANUFACTURED BY NEENAH FOUNDRY PER STANDARD DETAIL SD-06, OR APPROVED EQUAL. FRAMES AND COVER SHALL BE
MANUFACTURED IN THE UNITED STATES.
4.MANHOLES
a.STORM MANHOLES SHALL BE PER VDOT SPECIFICATIONS.
b.FRAMES AND COVERS SHALL BE AS MANUFACTURED BY NEENAH FOUNDRY PER STANDARD DETAIL SD-03 OR APPROVED
EQUAL.
c.ANY BRICK MANHOLE THAT IS AFFECTED BY CONSTRUCTION (TAPPED, RAISED OR OTHERWISE MODIFIED) MUST BE BROUGHT
UP TO CURRENT STANDARDS.
GM GAS METER
TRANSPORTATION
SITE DEVELOPMENT SUMMARY
TM # 90-A-58B
ZONING M-1 LIGHT INDUSTRIAL
SITE AREA 9.3918 AC.
SITE LOCATION VALLEY PIKE
DISTURBED AREA 1.629 AC. (70,977 SF)
CURRENT USE VACANT
PROPOSED USE COMMERCIAL (PARKING)
FLOOD PLAIN FEMA FLOOD MAP #51069C0320E
eff. 1/29/2021 ZONE: X - AREA OF
MINIMAL FLOOD HAZARD
BUILDING SETBACKS REQUIRED PROVIDED
FRONT 75'N/A
CORNER 75'N/A
SIDE 25'N/A
REAR 25'N/A
PARKING SETBACKS REQUIRED PROVIDED
FRONT 25'> 148'
SIDE 5'= 5'
REAR 5'> 87'
PARKING SCHEDULE
PROPOSED PARKING SPACES =102 SPACES
TOTAL ADA PARKING REQUIRED =4 SPACE
TOTAL ADA PARKING PROVIDED =5 SPACES (1 VAN)
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS1000.dwg PLOTTED: 9/30/2025 12:45 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275EXISTING CONDITIONSCS1000
SHEET 3 OF 19
U.S. ROUTE 11 - VALLEY PIKE
(VARIABLE WIDTH R/W)
TM#90-A-58B
FISHER SCIENTIFIC
COMPANY, LLC
#20170009047
ZONED: M1
TM#90-A-58C
MIDDLETOWN DATA CENTER, LLC
#20180010765
ZONED: M1
TM#90-A-58A
FISHER SCIENTIFIC
COMPANY, LLC
DB 957 PG 951
ZONED: M1
10'
5'
5C
5B
1B
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS1100.dwg PLOTTED: 9/30/2025 12:45 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTSOILS MAPCS1100
SHEET 4 OF 19 2025-09-08 00 30'60'
GRAPHIC SCALE 1"=30'
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS2000.dwg PLOTTED: 9/30/2025 12:45 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTEROSION & SEDIMENT CONTROL NARRATIVECS2000
SHEET 5 OF 19 2025-09-08 LONG TERM MAINTENANCE AND REPAIR PLAN
MOWING: ALL GRASSES SHOULD BE MOWED AT LEAST TWICE EACH YEAR. GRASSES SUCH AS TALL FESCUE
SHOULD BE MOWED IN EARLY SUMMER AFTER EMERGENCE OF THE HEADS ON COOL SEASON GRASSES. THEY
SHOULD BE MOWED AGAIN IN THE EARLY FALL TO PREVENT SEEDS OF ANNUAL WEEDS FROM MATURING.
MOWING OF LEGUMES SUCH AS SERICEA LESPEDEZA AND CROWN VETCH CAN BE PERMITTED TO GROW ON
THE DAM OR IN ANY PART OF THE EMERGENCY SPILLWAY.
LIMING AND FERTILIZING: THE SOIL SHOULD BE SAMPLED ACCORDING TO RECOMMENDED PROCEDURES AT
LEAST ONCE EVERY 4 YEARS. THE SAMPLE SHOULD BE TESTED AT A QUALIFIED SOIL TESTING LABORATORY
(SUCH AS THE ONE AT VPI&SU). LIME AND FERTILIZER SHOULD BE APPLIED IN ACCORDANCE WITH
RECOMMENDATIONS BASED ON THE TESTS.
REPLANTING AND OVER SEEDING: IF VEGETATION COVERS LESS THAN 40% OF THE SOIL SURFACE, LIME,
FERTILIZE AND SEED IN ACCORDANCE WITH CURRENT RECOMMENDATIONS FOR NEW SEEDING. IF
VEGETATION COVERS MORE THAN 40% BUT LESS THAN 70% OF THE SOIL SURFACE, LIME FERTILIZE AND OVER
SEED IN ACCORDANCE WITH CURRENT RECOMMENDATIONS.
REMOVING TRASH AND DEBRIS: TRASH, LITTER AND VEGETATION (OTHER THAN GRASS) WILL BE REMOVED
AS NEEDED (BUT NO LESS THAN TWO TIMES PER YEAR) TO PREVENT OBSTRUCTION TO THE FLOW OF WATER,
TO PREVENT MOVEMENT OF TRASH AND LITTER TO DOWNSTREAM PROPERTIES, TO MAINTAIN THE
INTEGRITY OF THE STRUCTURE, TO PROVIDE AN ATTRACTIVE APPEARANCE AND TO MINIMIZE WATER
POLLUTION.
REMOVING SEDIMENT: SOIL MATERIALS (INCLUDING CLAY, SILT, SAND AND GRAVEL) WILL BE REMOVED
BEFORE THE DETENTION POOL LOSES 10% OF THE DESIGNED STORAGE CAPACITY.
SEDIMENT DISPOSAL: SEDIMENT DISPOSAL SHOULD BE IN ACCORDANCE WITH CURRENT PROCEDURES FOR
DISPOSAL OF SEDIMENT. WHERE REQUIRED BY THE APPROPRIATE AUTHORITIES, THE SEDIMENT WILL BE
TESTED FOR APPROPRIATE POLLUTANTS AT THE OWNER'S EXPENSE BEFORE IT IS REMOVED FROM THE POND.
REPAIRS: REPAIR SLIDES, SLUMPS AND ERODED AREAS PROMPTLY AND IN A WORKMANLIKE MANNER TRASH
RACKS, PIPES, HEADWALLS, ETC. WILL BE MAINTAINED, REPAIRED AND/OR REPLACED AS NEEDED TO
MAINTAIN THE INTEGRITY OF THE STRUCTURE. EXPOSED METAL SURFACES WILL BE PAINTED TO MINIMIZE
DAMAGE DUE TO RUST.
MAINTENANCE INSPECTIONS: THE OWNER WILL BE RESPONSIBLE FOR INSPECTING EACH STORMWATER
MANAGEMENT STRUCTURE AFTER EACH SIGNIFICANT RAINFALL. ONCE EACH YEAR A REPRESENTATIVE OF
DEQ WILL JOINTLY INSPECT EACH STORMWATER MANAGEMENT STRUCTURE. APPROPRIATE ACTION WILL BE
TAKEN TO ENSURE APPROPRIATE MAINTENANCE. ALL MAINTENANCE COSTS WILL BE BORNE BY THE OWNER.
WHERE STRUCTURES ARE TO BE MAINTAINED BY MORE THAN ONE PARTY, ALLOCATION OF COSTS WILL BE IN
ACCORDANCE WITH TERMS SET FORTH IN THE MAINTENANCE AGREEMENT. KEYS TO LOCKED ACCESS POINTS
SHALL BE AVAILABLE TO DEQ PERSONNEL UPON REQUEST.
MAINTENANCE RECORDS: THE LANDOWNER, OR SOMEONE DESIGNATED BY THE LANDOWNER, SHALL
INSPECT THE DETENTION POND WITHIN 24 HOURS AFTER EACH RAINFALL EVENT OF ONE INCH OR MORE OF
RAIN. THE OWNER OR THE DESIGNEE SHALL KEEP WRITTEN RECORDS OF THESE INSPECTIONS. THE RECORDS
SHALL ALSO INCLUDE MAINTENANCE AND REPAIRS PERFORMED. COPIES OF THESE RECORDS SHALL BE
PROVIDED TO THE COUNTY UPON REQUEST.
THE WATER QUALITY FEATURES SHALL NOT BE MODIFIED IN ANY WAY WITHOUT PRIOR APPROVAL BY DEQ
AND FREDERICK COUNTY.
·TOPSOIL SHALL BE SPREAD AT A MINIMUM DEPTH OF 4".
·PULVERIZED AGRICULTURAL LIMESTONE SHALL BE INCORPORATED INTO SOIL AT A RATE OF 92 LBS. PER
1000 S.F. (2 TONS PER ACRE).
·FERTILIZE WITH 10-20-10 AT A RATE OF 12 LBS. PER 1000 S.F. (500 LBS. PER ACRE). SEED MIX SHALL
CONSIST OF 90% KENTUCKY 31 TALL FESUE AND 10% KENTUCKY BLUEGRASS APPLIED AT THE RATE OF
200 LBS. PER ACRE.
EROSION AND SEDIMENT CONTROL NARRATIVE
PROJECT DESCRIPTION
THIS PROJECT PROPOSES THE CREATION OF A PARKING LOT, ASSOCIATED LOT LIGHTING AND LANDSCAPING,
AND A STORM SEWER NETWORK TO COLLECT AND ROUTE STORM WATER.
EXISTING SITE CONDITIONS
THIS SITE IS CURRENTLY VACANT, OPEN, MANAGED TURF.
ADJACENT PROPERTY
THE SITE IS BOUND ON THE NORTH BY US ROUTE 11, VALLEY PIKE. IT IS SURROUNDED ON ALL OTHER SIDES BY
PROPERTIES ZONED M1 WITH LIGHT COMMERCIAL USES.
OFF-SITE AREAS
THERE ARE NO OFFSITE AREAS ANTICIPATED WITH THE CONSTRUCTION OF THIS PROJECT.
SOILS
THE AREA OF DEVELOPEMENT CONSISTS OF MOSTLY 5B SOILS, WITH SOME AREAS OF 1B AND 5C. SEE SHEET
CS1100 FOR SOILS MAP.
CRITICAL AREAS
CRITICAL AREAS, IF ANY, CONSIST OF 2.5 OR 3:1 SLOPES. THESE SLOPES HAVE THE POTENTIAL FOR GREATER
EROSION AND SHALL BE IMMEDIATELY STABILIZED AFTER REACHING FINAL GRADE. THERE ARE NO
ANTICIPATED CRITICAL AREAS IN THIS SITE.
EROSION AND SEDIMENT CONTROL MEASURES
UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL
MEASURES SHALL BE CONSTRUCTED AND MAINTAINED ACCORDING TO THE MINIMUM STANDARDS AND
SPECIFICATIONS OF THE VIRGINIA STORMWATER MAGAGEMENT HANDBOOK.
STRUCTURAL MEASURES
THE SEDIMENT BARRIERS AND OTHER MEASURES SHOWN ON THE PLANS INTENDED TO TRAP SEDIMENT
SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND-DISTURBING ACTIVITY AND SHALL BE MADE
FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE.
PHASE I:
CONSTRUCTION ENTRANCE WITH WASH RACK (C-SCM-03) SHALL BE INSTALLED AT THE LOCATION SHOWN ON
THE PHASE I PLAN TO PREVENT MUD AND DEBRIS FROM BEING TRACKED ONTO ROADWAYS.
SILT FENCE WITH WIRE SUPPORT (C-PCM-04) SHALL BE INSTALLED AS SHOWN ON THE PLANS TO FILTER
RUNOFF FROM DISTURBED AREAS BEFORE IT LEAVES THE SITE.
PERMANENT QUANTITY POND SHALL BE INSTALLED AS SHOWN AND MODIFIED TO OPERATE AS A PIPE
OUTLET SEDIMENT TRAP (C-SCM-11-5).
INLET PROTECTION WITH SILT FENCE (C-SCM-04) SHALL BE INSTALLED AS SHOWN ON PLANS TO FILTER
RUNOFF BEFORE IT LEAVES THE SITE.
TEMPORARY SEEDING (C-SSM-09) SHALL BE PLACED ON ALL CRITICAL SLOPES (3:1 OR GREATER) AND AS
NEEDED TO STABILIZE DISTURBED AREAS.
PHASE II:
ALL CONTROLS INSTALLED IN PHASE I SHOULD REMAIN UNTIL THE SITE IS STABILIZED.
CONVERT SEDIMENT POND TO ITS FINAL QUANTITY POND DESIGN.
INLET PROTECTION WITH GRAVEL (C-SCM-04) SHALL BE INSTALLED AS SHOWN ON PLANS TO FILTER RUNOFF
BEFORE IT LEAVES THE SITE.
CULVERT INLET PROTECTION WITH GRAVEL (C-SCM-05) SHALL BE INSTALLED AS SHOWN ON PLANS TO FILTER
RUNOFF BEFORE IT LEAVES THE SITE.
OUTLET PROTECTION (C-ECM-15) SHALL BE INSTALLED TO FILTER RUNOFF BEFORE IT LEAVES THE SITE.
TEMPORARY SEEDING (C-SSM-09) AND/OR PERMANENT SEEDING (C-SSM-10) SHALL BE PLACED ON ALL
CRITICAL SLOPES (3:1 OR GREATER) AND AS NEEDED TO STABILIZE DISTURBED AREAS.
VEGETATIVE MEASURES
PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN (7)
DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION
SHALL BE APPLIED WITHIN SEVEN (7) DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL
REMAIN DORMANT FOR LONGER THAN FOURTEEN (14) DAYS. PERMANENT SOIL STABILIZATION SHALL BE
APPLIED TO ALL AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN SIX (6) MONTHS.
SOIL THAT HAS BEEN STOCKPILED SHALL BE SURROUNDED WITH SILT FENCE AND PROTECTED BY MULCH
AND/OR TEMPORARY VEGETATION IMMEDIATELY AFTER GRADING.
ALL EARTH BERMS, DAMS, DIKES, DIVERSIONS AND SEDIMENT TRAP EMBANKMENTS ARE TO BE
MACHINE-COMPACTED, IMMEDIATELY SEEDED AND MULCHED (HAY MULCH OR STRAW) FOR TEMPORARY
AND/OR PERMANENT VEGETATIVE COVER WITHIN FIVE (5) DAYS AFTER GRADING.
MANAGEMENT STRATEGIES
CONSTRUCTION SHALL BE SEQUENCED SUCH THAT GRADING OPERATIONS WILL BEGIN AND END AS QUICKLY
AS POSSIBLE.
THE SITE SUPERINTENDENT SHALL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL
EROSION AND SEDIMENT CONTROL MEASURES. MAINTENANCE OF THESE MEASURES THROUGHOUT THE
PROJECT ARE CRITICAL TO THE EFFECTIVENESS OF THE PROGRAM.
AFTER AREAS ABOVE CONTROLS HAVE BEEN STABILIZED, THE CONTROLS SHALL BE CLEANED UP AND
REMOVED AT THE DIRECTION OF THE FREDERICK COUNTY INSPECTOR.
ALL CUT AND FILL SLOPES ARE TO BE SEEDED AND MULCHED WITHIN FIVE (5) DAYS OF COMPLETION OF
GRADING. CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE
EROSION. SLOPES THAT ARE FOUND TO BE ERODING EXCESSIVELY WITHIN ONE YEAR OF PERMANENT
STABILIZATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE STABILIZING MEASURES UNTIL THE PROBLEM IS
CORRECTED.
DRAINAGE SWALES SHALL BE STABILIZED WITH CHECK DAMS UNTIL VEGETATION HAS BEEN WELL
ESTABLISHED, AT WHICH TIME THE CHECK DAMS SHALL BE REMOVED.
CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN
ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME, OR SLOPE DRAIN STRUCTURE.
WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE
PROVIDED.
ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO
THAT SEDIMENT-LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED
OR OTHERWISE TREATED TO REMOVE SEDIMENT.
WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALL BE
MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE.
WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE
CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY
SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING
SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER.
ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER
FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS
OTHERWISE AUTHORIZED BY THE LOCAL PROGRAM AUTHORITY. TRAPPED SEDIMENT AND THE DISTURBED
SOILS AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY
STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION.
DEVICES LISTED ABOVE ARE CONSIDERED MINIMUM EROSION AND SEDIMENT CONTROLS. ADDITIONAL
CONTROL MEASURES MAY BE NECESSARY DUE TO CONTRACTOR PHASING OR OTHER UNFORESEEN
CONDITIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADDITIONAL MEASURES TO THOSE
SHOWN, AS NEEDED, IN ORDER TO CONTROL EROSION AND CONTAIN SEDIMENT ON SITE. ALL MEASURES
SHALL BE INSTALLED ACCORDING TO THE STANDARDS AND SPECIFICATIONS IN THE VIRGINIA STORMWATER
MANAGEMENT HANDBOOK (VSMH) v1.1. ANY CHANGES MADE TO THIS PLAN MUST BE RESUBMITTED FOR
APPROVAL WITHOUT EXCEPTION.
MAINTENANCE
ALL CONTROL MEASURES SHALL BE INSPECTED DAILY BY THE SITE SUPERINTENDENT OR HIS REPRESENTATIVE
AND WITHIN 24 HOURS AFTER ANY STORM EVENT GREATER THAN 0.5 INCHES OF RAIN PER 24 HOUR PERIOD.
ANY DAMAGED STRUCTURAL MEASURES ARE TO BE REPAIRED BY THE END OF THE DAY. SEEDED AREAS
SHALL BE CHECKED REGULARLY TO ENSURE THAT A GOOD STAND OF GRASS IS MAINTAINED. ALL AREAS
SHALL BE FERTILIZED AND RESEEDED AS NEEDED UNTIL GRASS IS ESTABLISHED.
TRAPPED SEDIMENT IS TO BE REMOVED AS REQUIRED TO MAINTAIN 50% TRAP EFFICIENCY AND DISPOSED OF
BY SPREADING ON SITE.
GRAVEL OUTLETS SHALL BE CHECKED REGULARLY FOR SEDIMENT BUILD-UP. IF THE GRAVEL OUTLET IS
CLOGGED BY SEDIMENT, IT SHALL BE REMOVED AND CLEANED OR REPLACED IMMEDIATELY.
THE CONTRACTOR IS RESPONSIBLE FOR KEEPING EXISTING PUBLIC ROADS IN A CLEAN, DUST AND MUD FREE,
CONDITION AT ALL TIMES.
PERMANENT STABILIZATION
ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE STABILIZED WITH PERMANENT SEEDING IMMEDIATELY
FOLLOWING FINAL GRADING. SEEDING SHALL BE DONE ACCORDING TO STANDARD AND SPECIFICATION NO.
C-SSM-10 OF THE VIRGINIA SMW HANDBOOK. PERMANENT STABILIZATION IS DEFINED AS 90% UNIFORM
COVERAGE ON THE ENTIRE SITE, ABILITY TO INHIBIT EROSION AND MATURE ENOUGH TO SURVIVE, INCLUDING
2-3 INCH CUTTINGS.
PHASES OF LAND DISTURBANCE ACTIVITIES
1.MANDATORY PRE-CONSTRUCTION CONFERENCE SHALL BE SCHEDULED AS REQUIRED BY REGULATIONS.
2.CLEARING AND GRUBBING FOR SEDIMENT CONTROL DEVICES ONLY.
3.INSTALLATION OF ALL PHASE I EROSION & SEDIMENT CONTROL DEVICES.
4.OBTAIN COUNTY INSPECTOR APPROVAL.
5.ROUGH GRADE SITE.
6.RESTORATION AND STABILIZATION OF DISTURBED AREAS.
7.REMOVE ALL EROSION & SEDIMENT CONTROL MEASURES WITH THE APPROVAL OF THE INSPECTOR.
9VAC25-875-560. MINIMUM STANDARDS.
A VESCP MUST BE CONSISTENT WITH THE FOLLOWING CRITERIA, TECHNIQUES AND METHODS:
1.PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS
REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS
THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN 14 DAYS. PERMANENT STABILIZATION SHALL BE
APPLIED TO AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN ONE YEAR.
2.DURING CONSTRUCTION OF THE PROJECT, SOIL STOCK PILES AND BORROW AREAS SHALL BE STABILIZED OR PROTECTED WITH
SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION
OF ALL SOIL STOCKPILES ON SITE AS WELL AS BORROW AREAS AND SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE.
3.A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON DENUDED AREAS NOT OTHERWISE PERMANENTLY STABILIZED.
PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT IS UNIFORM, MATURE
ENOUGH TO SURVIVE AND WILL INHIBIT EROSION.
4.SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE
CONSTRUCTED AS A FIRST STEP IN ANY LAND-DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND
DISTURBANCE TAKES PLACE.
5.STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONS IMMEDIATELY AFTER
INSTALLATION.
6.SEDIMENT TRAPS AND SEDIMENT BASINS SHALL BE DESIGNED AND CONSTRUCTED BASED UPON THE TOTAL DRAINAGE AREA TO BE
SERVED BY THE TRAP OR BASIN.
a.THE MINIMUM STORAGE CAPACITY OF A SEDIMENT TRAP SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA AND THE TRAP
SHALL ONLY CONTROL DRAINAGE AREAS LESS THAN THREE ACRES.
b.SURFACE RUNOFF FROM DISTURBED AREAS THAT IS COMPRISED OF FLOW FROM DRAINAGE AREAS GREATER THAN OR EQUAL TO
THREE ACRES SHALL BE CONTROLLED BY A SEDIMENT BASIN. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT BASIN SHALL BE 134
CUBIC YARDS PER ACRE OF DRAINAGE AREA. THE OUTFALL SYSTEM SHALL, AT A MINIMUM, MAINTAIN THE STRUCTURAL INTEGRITY
OF THE BASIN DURING A 25-YEAR STORM OF 24-HOUR DURATION. RUNOFF COEFFICIENTS USED IN RUNOFF CALCULATIONS SHALL
CORRESPOND TO A BARE EARTH CONDITION OR THOSE CONDITIONS EXPECTED TO EXIST WHILE THE SEDIMENT BASIN IS UTILIZED.
7.CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION. SLOPES THAT ARE FOUND
TO BE ERODING EXCESSIVELY WITHIN ONE YEAR OF PERMANENT STABILIZATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE
STABILIZING MEASURES UNTIL THE PROBLEM IS CORRECTED.
8.CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR
PERMANENT CHANNEL, FLUME OR SLOPE DRAIN STRUCTURE.
9.WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED.
10.ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT-LADEN
WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT.
11.BEFORE NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS OR PIPES ARE MADE OPERATIONAL, ADEQUATE OUTLET
PROTECTION AND ANY REQUIRED TEMPORARY OR PERMANENT CHANNEL LINING SHALL BE INSTALLED IN BOTH THE CONVEYANCE
CHANNEL AND RECEIVING CHANNEL.
12.WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS SHALL BE TAKEN TO MINIMIZE ENCROACHMENT, CONTROL
SEDIMENT TRANSPORT AND STABILIZE THE WORK AREA TO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NONERODIBLE
MATERIAL SHALL BE USED FOR THE CONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USED FOR THESE
STRUCTURES IF ARMORED BY NONERODIBLE COVER MATERIALS.
13.WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES MORE THAN TWICE IN ANY SIX-MONTH PERIOD, A
TEMPORARY VEHICULAR STREAM CROSSING CONSTRUCTED OF NONERODIBLE MATERIAL SHALL BE PROVIDED.
14.ALL APPLICABLE FEDERAL, STATE AND LOCAL REQUIREMENTS PERTAINING TO WORKING IN OR CROSSING LIVE WATERCOURSES SHALL
BE MET.
15.THE BED AND BANKS OF A WATERCOURSE SHALL BE STABILIZED IMMEDIATELY AFTER WORK IN THE WATERCOURSE IS COMPLETED.
16.UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER
APPLICABLE CRITERIA:
a.NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME.
b.EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES.
c.EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE,
OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF-SITE PROPERTY.
d.MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE
STABILIZATION.
e.RESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THIS CHAPTER.
f.APPLICABLE SAFETY REQUIREMENTS SHALL BE COMPLIED WITH.
17.WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE
TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED
OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE
REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET
WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SHALL APPLY TO INDIVIDUAL
DEVELOPMENT LOTS AS WELL AS TO LARGER LAND-DISTURBING ACTIVITIES.
18.ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION
OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE VESCP AUTHORITY.
TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE
PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION.
19.PROPERTIES AND WATERWAYS DOWNSTREAM FROM DEVELOPMENT SITES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION,
EROSION AND DAMAGE DUE TO INCREASES IN VOLUME, VELOCITY AND PEAK FLOW RATE OF STORMWATER RUNOFF FOR THE STATED
FREQUENCY STORM OF 24-HOUR DURATION IN ACCORDANCE WITH THE FOLLOWING STANDARDS AND CRITERIA. STREAM
RESTORATION AND RELOCATION PROJECTS THAT INCORPORATE NATURAL CHANNEL DESIGN CONCEPTS ARE NOT MAN-MADE
CHANNELS AND SHALL BE EXEMPT FROM ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE
CHANNELS:
a.CONCENTRATED STORMWATER RUNOFF LEAVING A DEVELOPMENT SITE SHALL BE DISCHARGED DIRECTLY INTO AN ADEQUATE
NATURAL OR MAN-MADE RECEIVING CHANNEL, PIPE OR STORM SEWER SYSTEM. FOR THOSE SITES WHERE RUNOFF IS DISCHARGED
INTO A PIPE OR PIPE SYSTEM, DOWNSTREAM STABILITY ANALYSES AT THE OUTFALL OF THE PIPE OR PIPE SYSTEM SHALL BE
PERFORMED.
b.ADEQUACY OF ALL CHANNELS AND PIPES SHALL BE VERIFIED IN THE FOLLOWING MANNER:
(1)THE APPLICANT SHALL DEMONSTRATE THAT THE TOTAL DRAINAGE AREA TO THE POINT OF ANALYSIS WITHIN THE CHANNEL IS 100
TIMES GREATER THAN THE CONTRIBUTING DRAINAGE AREA OF THE PROJECT IN QUESTION;
(2)(A) NATURAL CHANNELS SHALL BE ANALYZED BY THE USE OF A TWO-YEAR STORM TO VERIFY THAT STORMWATER WILL NOT
OVERTOP CHANNEL BANKS NOR CAUSE EROSION OF CHANNEL BED OR BANKS.
(b)ALL PREVIOUSLY CONSTRUCTED MAN-MADE CHANNELS SHALL BE ANALYZED BY THE USE OF A 10-YEAR STORM TO VERIFY THAT
STORMWATER WILL NOT OVERTOP ITS BANKS AND BY THE USE OF A TWO-YEAR STORM TO DEMONSTRATE THAT STORMWATER
WILL NOT CAUSE EROSION OF CHANNEL BED OR BANKS; AND
(c)PIPES AND STORM SEWER SYSTEMS SHALL BE ANALYZED BY THE USE OF A 10-YEAR STORM TO VERIFY THAT STORMWATER WILL BE
CONTAINED WITHIN THE PIPE OR SYSTEM.
c.IF EXISTING NATURAL RECEIVING CHANNELS OR PREVIOUSLY CONSTRUCTED MAN-MADE CHANNELS OR PIPES ARE NOT ADEQUATE,
THE APPLICANT SHALL:
(1)IMPROVE THE CHANNELS TO A CONDITION WHERE A 10-YEAR STORM WILL NOT OVERTOP THE BANKS AND A TWO-YEAR STORM
WILL NOT CAUSE EROSION TO THE CHANNEL, THE BED, OR THE BANKS.
(2)IMPROVE THE PIPE OR PIPE SYSTEM TO A CONDITION WHERE THE 10-YEAR STORM IS CONTAINED WITHIN THE APPURTENANCES;
(3)DEVELOP A SITE DESIGN THAT WILL NOT CAUSE THE PRE-DEVELOPMENT PEAK RUNOFF RATE FROM A TWO YEAR STORM TO
INCREASE WHEN RUNOFF OUTFALLS INTO A NATURAL CHANNEL OR WILL NOT CAUSE THE PRE-DEVELOPMENT PEAK RUNOFF RATE
FROM A 10-YEAR STORM TO INCREASE WHEN RUNOFF OUTFALLS INTO A MAN-MADE CHANNEL; OR
(4)PROVIDE A COMBINATION OF CHANNEL IMPROVEMENT, STORMWATER DETENTION OR OTHER MEASURES WHICH IS SATISFACTORY
TO THE VESCP AUTHORITY TO PREVENT DOWNSTREAM EROSION
d.THE APPLICANT SHALL PROVIDE EVIDENCE OF PERMISSION TO MAKE THE IMPROVEMENTS.
e.ALL HYDROLOGIC ANALYSES SHALL BE BASED ON THE EXISTING WATERSHED CHARACTERISTICS AND THE ULTIMATE DEVELOPMENT
CONDITION OF THE SUBJECT PROJECT.
f.IF THE APPLICANT CHOOSES AN OPTION THAT INCLUDES STORMWATER DETENTION, HE SHALL OBTAIN APPROVAL FROM THE VESCP
OF A PLAN FOR MAINTENANCE OF THE DETENTION FACILITIES. THE PLAN SHALL SET FORTH THE MAINTENANCE REQUIREMENTS OF
THE FACILITY AND THE PERSON RESPONSIBLE FOR PERFORMING THE MAINTENANCE.
g.OUTFALL FROM A DETENTION FACILITY SHALL BE DISCHARGED TO A RECEIVING CHANNEL, AND ENERGY DISSIPATERS SHALL BE
PLACED AT THE OUTFALL OF ALL DETENTION FACILITIES AS NECESSARY TO PROVIDE A STABILIZED TRANSITION FROM THE FACILITY TO
THE RECEIVING CHANNEL.
h.ALL ON-SITE CHANNELS MUST BE VERIFIED TO BE ADEQUATE.
i.INCREASED VOLUMES OF SHEET FLOWS THAT MAY CAUSE EROSION OR SEDIMENTATION ON ADJACENT
PROPERTY SHALL BE DIVERTED TO A STABLE OUTLET, ADEQUATE CHANNEL, PIPE OR PIPE SYSTEM, OR TO A
DETENTION FACILITY.
j.IN APPLYING THESE STORMWATER MANAGEMENT CRITERIA, INDIVIDUAL LOTS OR PARCELS IN A RESIDENTIAL,
COMMERCIAL OR INDUSTRIAL DEVELOPMENT SHALL NOT BE CONSIDERED TO BE SEPARATE DEVELOPMENT
PROJECTS. INSTEAD, THE DEVELOPMENT, AS A WHOLE, SHALL BE CONSIDERED TO BE A SINGLE DEVELOPMENT
PROJECT. HYDROLOGIC PARAMETERS THAT REFLECT THE ULTIMATE DEVELOPMENT CONDITION SHALL BE USED
IN ALL ENGINEERING CALCULATIONS.
k.ALL MEASURES USED TO PROTECT PROPERTIES AND WATERWAYS SHALL BE EMPLOYED IN A MANNER WHICH
MINIMIZES IMPACTS ON THE PHYSICAL, CHEMICAL AND BIOLOGICAL INTEGRITY OF RIVERS, STREAMS AND
OTHER WATERS OF THE STATE.
l.ANY PLAN APPROVED PRIOR TO JULY 1, 2014, THAT PROVIDES FOR STORMWATER MANAGEMENT THAT
ADDRESSES ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE
CHANNELS SHALL SATISFY THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR
MAN-MADE CHANNELS IF THE PRACTICES ARE DESIGNED TO (I) DETAIN THE WATER QUALITY VOLUME AND TO
RELEASE IT OVER 48 HOURS; (II) DETAIN AND RELEASE OVER A 24-HOUR PERIOD THE EXPECTED RAINFALL
RESULTING FROM THE ONE YEAR, 24-HOUR STORM; AND (III) REDUCE THE ALLOWABLE PEAK FLOW RATE
RESULTING FROM THE 1.5, 2, AND 10-YEAR, 24-HOUR STORMS TO A LEVEL THAT IS LESS THAN OR EQUAL TO
THE PEAK FLOW RATE FROM THE SITE ASSUMING IT WAS IN A GOOD FORESTED CONDITION, ACHIEVED
THROUGH MULTIPLICATION OF THE FORESTED PEAK FLOW RATE BY A REDUCTION FACTOR THAT IS EQUAL TO
THE RUNOFF VOLUME FROM THE SITE WHEN IT WAS IN A GOOD FORESTED CONDITION DIVIDED BY THE
RUNOFF VOLUME FROM THE SITE IN ITS PROPOSED CONDITION, AND SHALL BE EXEMPT FROM ANY FLOW RATE
CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS AS DEFINED IN ANY
REGULATIONS PROMULGATED PURSUANT TO § 62.1-44.15:54 OR 62.1-44.15:65 OF THE ACT.
m.FOR PLANS APPROVED ON AND AFTER JULY 1, 2014, THE FLOW RATE CAPACITY AND VELOCITY
REQUIREMENTS OF § 62.1-44.15:52 A OF THE ACT AND THIS SUBSECTION SHALL BE SATISFIED BY COMPLIANCE
WITH WATER QUANTITY REQUIREMENTS IN THE STORMWATER MANAGEMENT ACT (§ 62.1-44.15:24 ET SEQ.
OF THE CODE OF VIRGINIA) AND ATTENDANT REGULATIONS, UNLESS SUCH LAND-DISTURBING ACTIVITIES (I)
ARE IN ACCORDANCE WITH PROVISIONS FOR TIME LIMITS ON APPLICABILITY OF APPROVED DESIGN CRITERIA IN
9VAC25-870-47 OR GRANDFATHERING IN 9VAC25-870-48 OF THE VIRGINIA STORMWATER MANAGEMENT
PROGRAM (VSMP) REGULATION, IN WHICH CASE THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS OF
§ 62.1-44.15:52 A OF THE ACT SHALL APPLY, OR (II) ARE EXEMPT PURSUANT TO § 62.1-44.15:34 C 7 OF THE ACT.
n.COMPLIANCE WITH THE WATER QUANTITY MINIMUM STANDARDS SET OUT IN 9VAC25-870-66 OF THE
VIRGINIA STORMWATER MANAGEMENT PROGRAM (VSMP) REGULATION SHALL BE DEEMED TO SATISFY THE
REQUIREMENTS OF THIS SUBDIVISION 19.
SEEDING REQUIREMENTS
2 TONS STRAW MULCH PER AC.
3 TONS AGRICULTURAL LIMESTONE PER AC.
1000 LBS. 10-20-20 FERTILIZER PER AC.
PERMANENT STABILIZATION: ALL DISTURBED AREAS NOT PAVED WILL RECEIVE
200 LBS. TALL FESCUE PER AC.
20 LBS. ANNUAL RYE PER AC.
AT A MINIMUM 4" OF TOPSOIL AND BE SEEDED AS FOLLOWS:MORE THAN SEVSN DAYS, BUT NOT YET AT FINAL GRADE SHALL BE AS FOLLOWS:
60 LBS. GERMAN MILLET PER AC. (MAY THRU SEPTEMBER)
60 LBS. ANNUAL RYE PER AC. (OCTOBER THRU APRIL)
450 LBS. 10-20-20 FERTILIZER PER AC.
3 TONS AGRICULTURAL LIMESTONE PER AC.
2 TONS STRAW MULCH PER AC.
TEMPORARY STABILIZATION: SEEDING TO STABILIZED AREAS LEFT DENUDED FOR
U.S. ROUTE 11 - VALLEY PIKE
(VARIABLE WIDTH R/W)
TM#90-A-58B
FISHER SCIENTIFIC
COMPANY, LLC
#20170009047
ZONED: M1
TM#90-A-58C
MIDDLETOWN DATA CENTER, LLC
#20180010765
TM#90-A-58A
FISHER SCIENTIFIC
COMPANY, LLC
DB 957 PG 951
ZONED: M1
10'
5'
CE
SF
SF SF
IP
SF
715.00 (LP)
722.00 (TOP OF SETTLED BERM)
720.25 (8' WIDE GRASS EMERGENCY SPILLWAY)
722
720
716
722
722
720 719
ST
REMOVE & DISPOSE
26 METAL SIGN POSTS
REMOVE & DISPOSE
BUSHES
REMOVE & DISPOSE
±324 SF HEDGE LINE
REMOVE & DISPOSE
±457 SF HEDGE LINE
X
X
X
X
X
X
X
X
X X X
X X X X X
X X X X X
X X X X
X
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS2100.dwg PLOTTED: 9/30/2025 12:45 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTDEMO PLAN AND EROSION &SEDIMENT CONTROL PLAN - PHASE ICS2100
SHEET 6 OF 19 2025-09-08 00 30'60'
GRAPHIC SCALE 1"=30'
EROSION AND SEDIMENT
CONTROL LEGEND
NO.TITLE KEY SYMBOL
C-SCM-03 TEMPORARY STONE
CONSTRUCTION ENTRANCE CE
C-SCM-04 STORM DRAIN
INLET PROTECTION IP
C-ECM-15 OUTLET PROTECTION OP
C-PCM-04 SILT FENCE SF
LIMITS OF DISTURBANCE LOD
DRAINAGE DIVIDES
C-SCM-11 TEMPORARY SEDIMENT
TRAP ST ST-1
U.S. ROUTE 11 - VALLEY PIKE
(VARIABLE WIDTH R/W)
TM#90-A-58B
FISHER SCIENTIFIC
COMPANY, LLC
#20170009047
ZONED: M1
TM#90-A-58C
MIDDLETOWN DATA CENTER, LLC
#20180010765
ZONED: M1
TM#90-A-58A
FISHER SCIENTIFIC
COMPANY, LLC
DB 957 PG 951
ZONED: M1
10'
5'
CE
SF
OP
SF
IP
IP
IP
IP
IP
CIP
SF
IP
SF
715.00 (LP)
722.00 (TOP OF SETTLED BERM)
720.25 (8' WIDE GRASS EMERGENCY SPILLWAY)
722
720
716
722
722
720 719
OP
9
22
8
19 19 25
VALLEY PIKE
US RTE. 11
VARIABLE WIDTH R/W
PR. 30" CONC. SLAB
FOR LIGHT POLE
LIMITS
OF WP-2
5 PR. HC
PRKG SIGNS
PR. STOP
SIGN
727
728726
727
726
72
5
72
4
724
7
2
3
722
725
725
722
721720
719 718
717
716
722
722
721
720 719
722
721
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD = 1.63 ACRES
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS2200.dwg PLOTTED: 9/30/2025 12:46 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTEROSION & SEDIMENT CONTROL PLAN- PHASE IICS2200
SHEET 7 OF 19 2025-09-08 00 30'60'
GRAPHIC SCALE 1"=30'
EROSION AND SEDIMENT
CONTROL LEGEND
NO.TITLE KEY SYMBOL
C-SCM-03 TEMPORARY STONE
CONSTRUCTION ENTRANCE CE
C-SCM-04 STORM DRAIN
INLET PROTECTION IP
C-ECM-15 OUTLET PROTECTION OP
C-PCM-04 SILT FENCE SF
LIMITS OF DISTURBANCE LOD
DRAINAGE DIVIDES
C-SCM-05 CULVERT INLET
PROTECTION CIP
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS2500.dwg PLOTTED: 9/30/2025 12:46 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTEROSION & SEDIMENT CONTROL DETAILSCS2500
SHEET 8 OF 19 2025-09-08
U.S. ROUTE 11 - VALLEY PIKE
(VARIABLE WIDTH R/W)
TM#90-A-58B
FISHER SCIENTIFIC
COMPANY, LLC
#20170009047
ZONED: M1
TM#90-A-58C
MIDDLETOWN DATA CENTER, LLC
#20180010765
ZONED: M1
TM#90-A-58A
FISHER SCIENTIFIC
COMPANY, LLC
DB 957 PG 951
ZONED: M1
10'
25' PARKING SETBACK
5' PARKING SETBACK5' PARKING SETBACK 5' PARKING SETBACK5'
9
8.0'
9.0'20.0'24.0'24.0'
20.0'9.0'20.0'9.0'24.0'24.0'24.0'
20.0'9.0'5.0'
5'
22
8
19 19 25
20.0'9.0'
VALLEY PIKE
US RTE. 11
VARIABLE WIDTH R/W
R=4.5
5.0'
5' CONC. SIDEWALK
PR. 30" CONC. SLAB
FOR LIGHT POLE
R=4.5
24.0'R=5.0
R=5.0
R=5.0 R=5.0
R=4.5
LIMITS
OF WP-2
5 PR. HC
PRKG SIGNS
CG-6
CG-6
CG-6
CG-6
CG-6 CG-6CG-6CG-6CG-6CG-6RCG-6R
PR. STOP
SIGN
727
728726
727
726
72
5
72
4
724
7
2
3
722
725
725
722
721720
719 718
717
716
722
722
721
720 719
722
721
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS4000.dwg PLOTTED: 9/30/2025 12:46 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTGEOMETRIC PLANCS4000
SHEET 9 OF 19 2025-09-08 00 30'60'
GRAPHIC SCALE 1"=30'
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS4500.dwg PLOTTED: 9/30/2025 12:46 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTSITE DETAILSCS4500
SHEET 10 OF 19 2025-09-08 (STANDARD DUTY)
ASPHALT PAVEMENT
NTS
1 1 2" SURFACE COURSE (SM 12.5A)
2" IM 19.0
COMPACTED SUBGRADE
6" DENSE GRADED STONE (21B)
CONCRETE SIDEWALK
NTS
4" CONCRETE
4" DENSE GRADED STONE (21B)
COMPACTED SUBGRADE
NOT TO SCALE
R1-1 STOP SIGN - DETAIL
U.S. ROUTE 11 - VALLEY PIKE
(VARIABLE WIDTH R/W)
TM#90-A-58B
FISHER SCIENTIFIC
COMPANY, LLC
#20170009047
ZONED: M1
TM#90-A-58C
MIDDLETOWN DATA CENTER, LLC
#20180010765
ZONED: M1
TM#90-A-58A
FISHER SCIENTIFIC
COMPANY, LLC
DB 957 PG 951
ZONED: M1
10'
5'
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD = 1.63 ACRES
9
22
8
19 19 25
VALLEY PIKE
US RTE. 11
VARIABLE WIDTH R/W
LIMITS
OF WP-2
CG-6
CG-6
CG-6
CG-6
CG-6 CG-6CG-6CG-6CG-6CG-6RCG-6R
EX
SWM
1
2
3
4
6
4A
10
11
5
727
728726
727
726
72
5
72
4
724
7
2
3
722
725
725
723.10 (MATCH EX)
724.95 (MATCH EX)
726.10 (TC-PC)
726.85 (TC-PT)
726.50 (HP-MID-EP)
726.55 (TC-PC)
725.90 (LP-CORNER BAY-EP)
726.90 (HP-EP)
722.50 (HP)
727.90 (HP-TC)
726.00 (TC-CORNER BAY)
727.00 (TC)
726.25 (TC)
727.45 (TC)
726.50 (TC-CORNER BAY)725.50 (LP-TC)
726.00 (HP-TC)
727.55 (HP-EP)
726.75 (MID-EP)726.60 (MID-EP)
726.95 (HP-PC-EP)
726.50 (EP)
726.70 (LP-EP)
726.70 (HP-EP)
725.00 (TC-PC)
724.85 (LP-TC)
725.50 (TC)
725.80 (HP-TC-PT)
722.00 (ADA C/L)
724.95 (ADA C/L)
725.50 (HP-ADA C/L)
723.00 (ADA C/L)
724.00 (ADA C/L)
724.80 (ADA C/L)
727.00 (EP)
728.10 (HP)
727.25 (HP-TC)
725.60 (MID-EP)
725.75 (PC-EP)725.60 (PC-EP)
725.85 (PC)725.85 (PC)
725.60 (MID-EP)
715.00 (LP)
725.05 (TC CORNER BAY)725.20 (ADA C/L)
722.00 (TOP OF SETTLED BERM)
720.25 (8' WIDE GRASS EMERGENCY SPILLWAY)
720.00 (INV)
720.25 (INV)
722
721720
719 718
717
716
722
722
721
720 719
722
721
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS6000.dwg PLOTTED: 9/30/2025 12:46 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTGRADING & DRAINAGE PLANCS6000
SHEET 11 OF 19 2025-09-08 00 30'60'
GRAPHIC SCALE 1"=30'
1 2 3 4 5 6
EX SWM
4 4A
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS6100.dwg PLOTTED: 9/30/2025 12:47 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTSTORM SEWER PROFILES &CALCULATIONSCS6100
SHEET 12 OF 19 2025-09-08
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS6500.dwg PLOTTED: 9/30/2025 12:47 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTSTORM SEWER DETAILSCS6500
SHEET 13 OF 19 2025-09-08
U.S. ROUTE 11 - VALLEY PIKE
(VARIABLE WIDTH R/W)
FISHER SCIENTIFIC
COMPANY, LLC
TM#90-A-58C
MIDDLETOWN DATA CENTER, LLC
#20180010765
ZONED: M1
TM#90-A-58A
FISHER SCIENTIFIC
COMPANY, LLC
DB 957 PG 951
ZONED: M1
10'
25' PARKING SETBACK
5' PARKING SETBACK5' PARKING SETBACK
5'
28-BS
27-FO
IL-23
IL-21
AR-2
ZS-3
GB-3
UP-5
GB-7
AR-3
UP-3EX. HEDGE TO SERVE AS HEADLIGHT SCREENING ALONG WESTERN BOUNDARY OF PARKING LOTALTERNATE
COMMON BOXWOOD
WITH FORSYTHIA
ZS-1
9
22
8
19 19 25
VALLEY PIKE
US RTE. 11
VARIABLE WIDTH R/W
PR. 30" CONC. SLAB
FOR LIGHT POLE
LIMITS
OF WP-2
5 PR. HC
PRKG SIGNS
PR. STOP
SIGN
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD = 1.63 ACRES
727
728726
727
726
72
5
72
4
724
7
2
3
722
725
725
722
721720
719 718
717
716
722
722
721
720 719
722
721
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS7000 .dwg PLOTTED: 9/30/2025 12:47 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTLANDSCAPING PLAN, CALCULATIONS& DETAILSCS7000
SHEET 14 OF 19 2025-09-08 00 30'60'
GRAPHIC SCALE 1"=30'
GENERAL PLANT LIST
SYMBOL BOTANICAL NAME COMMON NAME SIZE SPACING QUANTITY
TREES
GB GINKGO BILOBA GINKGO (MALE)2" CAL @ 6" ABOVE GRADE
MIN.AS SHOWN 10
UP ULMUS PARVIFOLIA LACEBARK ELM 2" CAL @ 6" ABOVE GRADE
MIN.AS SHOWN 8
ZS ZELKOVA SERRATA JAPANESE ZELKOVA 2" CAL @ 6" ABOVE GRADE
MIN.AS SHOWN 4
AR ACER RUBRUM RED MAPLE 2" CAL @ 6" ABOVE GRADE
MIN.AS SHOWN 5
SHRUBS & SCREENING
BS BUXUS SEMPERVIRENS COMMON BOXWOOD 3' MIN. HEIGHT 4' O.C.28
IL ILEX (ALL VARIETIES)HOLLY 3' MIN. HEIGHT 4' O.C.44
FO ALL VARIETIES FORSYTHIA 3' MIN. HEIGHT 4' O.C.27
LANDSCAPE CALCULATIONS:
LANDSCAPING GENERAL CONDITIONS:
SCOPE OF WORK
THE LANDSCAPE CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR AND EQUIPMENT TO COMPLETE ALL LANDSCAPE WORK AS SHOWN ON THE PLANS AND SPECIFICATIONS.
NOTE: IF THE CONTRACTOR BIDS ACCORDING TO THE PLANT LIST, HE/SHE SHOULD THOROUGHLY CHECK THE PLANT LIST QUANTITIES WITH THE SYMBOLS DRAWN ON THE PLAN TO BE SURE
THERE ARE NO DISCREPANCIES. IF THERE IS A DISCREPANCY BETWEEN THE DRAWING AND THE LIST ON THE PLANS, THE DRAWING TAKES PRECEDENCE.
STANDARDS
A.ALL PLANT MATERIAL WILL CONFORM TO THE CURRENT ISSUE OF THE AMERICAN STANDARD FOR NURSERY STOCK PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION
(ANLA).
B.PLANT MATERIAL MUST BE SELECTED FROM NURSERIES THAT HAVE BEEN INSPECTED AND CERTIFIED BY STATE PLANT INSPECTORS.
C.COLLECTED MATERIAL MAY BE USED ONLY WHEN APPROVED BY OWNER'S REPRESENTATIVE.
D.NOMENCLATURE WILL BE IN ACCORDANCE WITH HORTUS III BY L.H. BAILEY.
SUBSTITUTIONS:PRE-BID
IT IS THE LANDSCAPE CONTRACTOR'S RESPONSIBILITY TO MAKE EVERY REASONABLE EFFORT TO FIND THE MATERIAL SPECIFIED BY THE ARCHITECT. THE LANDSCAPE CONTRACTOR MAY
OFFER SUBSTITUTIONS TO THE LANDSCAPE ARCHITECT FOR HIS/HER CONSIDERATION. THE LANDSCAPE CONTRACTOR WILL NOTIFY THE LANDSCAPE ARCHITECT IF THERE ARE KNOWN
DISEASES OR INSECT RESISTANT SPECIES THAT CAN BE SUBSTITUTED FOR A SELECTED PEST-PRONE PLANT. THE CONTRACTOR SHALL SUBMIT A BASE BID AS PER PLAN PLUS PRICE
CLARIFICATIONS FOR ALL RECOMMENDED SUBSTITUTIONS.
SUBSTITUTIONS:POST-BID
IT IS THE INTENT TO ELIMINATE POST-BID SUBSTITUTIONS. HOWEVER, IN THE EVENT THAT THE CONTRACT MATERIAL HAS BECOME UNAVAILABLE, AN APPROPRIATE SUBSTITUTION MUST BE
APPROVED BY THE OWNER'S REPRESENTATIVE.
UTILITIES AND UNDERGROUND FEATURES
THE LANDSCAPE CONTRACTOR SHALL NOTIFY UTILITY COMPANIES AND/OR THE GENERAL CONTRACTOR IN ADVANCE OF CONSTRUCTION TO LOCATE UTILITIES.
A.IF THERE IS A CONFLICT WITH THE UTILITIES AND THE PLANTING, THE LANDSCAPE ARCHITECT SHALL BE RESPONSIBLE FOR RELOCATING PLANTS PRIOR TO THE PLANTING PROCESS. ANY
COST DUE TO RELOCATING AFTER PLANTING SHALL BE BORNE BY THE OWNER.
DRAINAGE
IF PLANTS ARE TO BE INSTALLED IN AREAS THAT SHOW OBVIOUS POOR DRAINAGE, AND THE PLANTS ARE INAPPROPRIATE FOR THAT CONDITION, THE PLANTS SHALL BE RELOCATED, THE
CONTRACT SHALL BE ADJUSTED TO ALLOW FOR DRAINAGE CORRECTION AT A NEGOTIATED COST, OR THE PLANT SELECTION SHALL BE MODIFIED BY THE LANDSCAPE ARCHITECT TO
ACCOMMODATE THE POOR DRAINAGE SITUATION.
WARRANTY
A.THE STANDARD WARRANTY IS FOR A ONE (1) YEAR PERIOD, EXCLUDING BULBS, SOD AND ANNUALS, COMMENCING ON THE DATE OF INITIAL ACCEPTANCE. ALL PLANTS SHALL BE ALIVE
AND IN SATISFACTORY GROWTH AT THE END OF THE GUARANTEE PERIOD.
B.BALLED AND BURLAPPED (B&B).
1. BALLED AND BURLAPPED PLANTS SHALL BE DUG WITH FIRM ROOT BALLS FREE OF NOXIOUS WEEDS. THERE SHOULD BE NO EXCESS SOIL ON TOP OF THE ROOT BALL OR AROUND
THE TRUNK.
2. BALL SIZE SHALL BE IN ACCORDANCE WITH ANLA STANDARDS.
3. CALIPER AND HEIGHT MEASUREMENTS: IN SIZE GRADING B&B SINGLE-TRUNK TREES, CALIPER SHALL TAKE PRECEDENCE OVER HEIGHT. CALIPER OF THE TRUNK SHALL BE TAKEN
6" ABOVE THE GROUND LEVEL (UP TO/ INCLUDING 4" CALIPER SIZE) AND 12" ABOVE THE GROUND LEVEL OF LARGER TREES. FOR MULTIPLE-TRUNK TRESS, HEIGHT MEASUREMENT
SHALL TAKE PRECEDENCE OVER CALIPER.
C.CONTAINER-GROWN STOCK
1. THE SIZE OF CONTAINER-GROWN SHRUBS IS MEASURED BY HEIGHT AND WIDTH OF PLANT. CONTAINER-GROWN TREES ARE MEASURED BY THE SAME STANDARDS LISTED IN B.3
ABOVE. THE ROOT SYSTEM OF CONTAINER-GROWN PLANTS SHALL BE WELL-DEVELOPED AND WELL-DISTRIBUTED THROUGHOUT THE CONTAINER.
2. ALL CONTAINER-GROWN TREES AND SHRUBS THAT HAVE CIRCLING AND MATTED ROOTS SHALL BE TREATED IN THE FOLLOWING MANNER PRIOR TO PLANTING: USING A KNIFE OR
SHARP BLADE, MAKE 4-5 CUTS, 1" DEEP, THE LENGTH OF THE ROOT BALL, TO CUT ALL CIRCLING ROOTS. SEE PLANTING PROCEDURES FOR ALL CONTAINER-GROWN TREES & SHRUBS IN
THIS SECTION.
3. ALL CONTAINER-GROWN PLANTS SHOULD BE GROUPED AND WATERED DAILY UNTIL THEY ARE PLANTED IN THE LANDSCAPE. THE SOIL SHALL BE KEPT MOIST WITH THE
EQUIVALENT OF ONE INCH OF RAINFALL PER WEEK.
MAINTANENCE
A.PRUNING SHALL BE DONE BEFORE PLANTING OR DURING THE PLANTING OPERATION. PRUNING DETAIL FOR TREES IN THIS SECTION.
B.ALL PLANT MATERIAL IN TRANSIT SHALL BE COVERED TO KEEP MATERIAL FROM DRYING OUT. THE COVERING SHALL COMPLY WITH STATE AND LOCAL LAWS PERTAINING TO THE
TRANSPORT OF MATERIALS.
C.TREES SHALL BE PLACED IN AN UPRIGHT POSITION WITH THE ROOTBALL COVERED BY MULCH AND KEPT MOIST. TREES AND SHRUBS SHOULD NOT BE LEFT ON SITE UNPLANTED FOR
MORE THAN 24 HOURS WITHOUT ADEQUATE WATER TO INSURE ROOTS SURVIVAL.
INSPECTION
A.PLANTS MAY BE SUBJECT TO INSPECTION AND APPROVAL BY THE OWNER OR OWNER'S REPRESENTATIVE AT THE PLACE OF GROWTH OR HOLDING YARD FOR CONFORMITY TO
SPECIFICATION REQUIREMENTS AS TO QUALITY, SIZE AND VARIETY.
B.PLANTS DAMAGED IN HANDLING OR TRANSPORTATION CAN BE REJECTED BY THE OWNER OR OWNER'S REPRESENTATIVE.
C.STATE NURSERY INSPECTION CERTIFICATES SHALL BE FURNISHED TO THE LANDSCAPE ARCHITECT UPON REQUEST.
PLANTING PROCEDURES FOR ALL CONTAINER-GROWN TREES & SHRUBS
A.REMOVE THE PLANT EITHER BY CUTTING OR INVERTING THE CONTAINER.
B.FOR UNTREATED PLASTIC CONTAINER GROWN PLANTS WITH CIRCLING ROOTS, USE A SHARP KNIFE TO MAKE 1" CUTS THE LENGTH OF THE ROOTBALL.
C.PLANT SHRUB TO TREE A MINIMUM OF 1/8 OF THE HEIGHT OF THE ROOTBALL ABOVE EXISTING GRADE.
D.APPLY A 2 TO 3" THICK LAYER OF APPROVED MULCH. KEEP MULCH 6" AWAY FROM THE TRUNK OF ALL TREES AND SHRUBS.
E.PLANTS GROWN IN ROOT CONTAINMENT BAGS MUST HAVE THE BAGS REMOVED DURING THE PLANTING OPERATION. NO ADDITIONAL SLASHING OF THE ROOTBALL IS NECESSARY.
MAINTENANCE OF LANDSCAPING NOTES:
1. ALL LANDSCAPED AREA SHALL BE MAINTAINED IN GOOD CONDITION BY
OWNER.
2. REASONABLE PROVISIONS SHALL BE MADE FOR PROTECTION FROM VEHICLES
OR PEDESTRIANS.
3. DEAD OR DYING VEGETATION SHALL BE REPLACED AT DIRECTION OF
ADMINISTRATOR.
4. SHRUBS SHALL BE REPLACED AT A SIZE CONSISTENT WITH THAT OF EXPECTED
FOR SPECIES AND TIME SINCE INSTALLATION.
5. TREES SHALL BE REPLACED AT A SIZE OF 0.5" CALIPER ABOVE 2" FOR EVERY
YEAR SINCE INSTALLATION UP TO 5" CALIPER.
TREE PLANTING
NOT TO SCALE
3x DIAMETER OF ROOT BALL
SET TRUNK PLUMB
L
DO NOT MULCH WITHIN
6" OF TRUNK
3" OF MULCH
SLOPE SIDES OF PLANTING HOLE
REMOVE BURLAP OR WIRE
BASKET FROM TOP
1/3 OF ROOT BALL
TAMP SOIL AROUND ROOT BALL
BASE FIRMLY WITH FOOT PRESSURE
TO PREVENT ROOT BALL FROM
SHIFTING
SECURE GUYS WITH RUBBER
HOSE TO TRUNK
PRUNE ONLY DAMAGED
OR DEAD BRANCHES
*(2) 2"x2" WOOD STAKES
SET AT 180° (ALT: STEEL
FENCE POSTS)
C
NOTES:
1.*STAKE ONLY TO PREVENT
WIND TIP OR WHEN PLANTING
ON STEEP SLOPES
2. REMOVE ALL TAGS AND
ROPES FROM BRANCHES AND
ROOT BALL.
PITCH FROM C OF PLANTING AREA
TYPICAL MULCH EDGING DETAIL4" MIN.MULCH LAYER
TOPSOIL
L
PROVIDE EDGE WITH CLEAN, CRISP SEPARATION
BETWEEN MULCHED BED AND ADJACENT SURFACE
CONDITIONS
CUT EDGE MINIMUM 4"
BELOW GRADE TO RECEIVE
MULCH
TURF, SIDEWALK, OR CURB 2" MIN. MULCH LAYER
NOT TO SCALE
SHRUB PLANTING
NOT TO SCALE
3x DIAMETER OF ROOT BALL
OR CONTAINER SIZE
2" OF MULCH
CREATE A SAUCER SHAPE
WITH MULCH TO HOLD WATER
SLOPE SIDES OF PLANTING HOLE
REMOVE BURLAP OR WIRE
BASKET FROM TOP
1/3 OF ROOT BALL
TAMP SOIL AROUND ROOT BALL
BASE FIRMLY TO PREVENT
ROOT BALL FROM SHIFTING
PRUNE ONLY DAMAGED
OR DEAD BRANCHES
PARKING LOT LANDSCAPING CALCULATIONS
PROPOSED OFF-STREET PARKING AREA 35,867 SF
LANDSCAPED AREA REQUIRED 1,793 SF (5%)
LANDSCAPED AREA PROVIDED 2,911 SF (8%)
IMPERVIOUS AREA LANDSCAPING CALCULATIONS
TOTAL IMPERVIOUS AREA 33,077 SF
TREES REQUIRED @ 1 PER 2000SF
IMPERVIOUS AREA (FIRST 100K)17
TREES PROVIDED 17
3' HEADLIGHT SCREEN PROVIDED
PARKING SPACE LANDSCAPING CALCULATIONS
NUMBER OF PARKING SPACES 102
TREES REQUIRED @ 1 PER 10 SPACES 10
TREES PROVIDED 10
9
22
8
19 19 25
VALLEY PIKE
US RTE. 11
VARIABLE WIDTH R/W
PR. 30" CONC. SLAB
FOR LIGHT POLE
LIMITS
OF WP-2
5 PR. HC
PRKG SIGNS
PR. STOP
SIGN
U.S. ROUTE 11 - VALLEY PIKE
(VARIABLE WIDTH R/W)
TM#90-A-58B
FISHER SCIENTIFIC
COMPANY, LLC
#20170009047
ZONED: M1
TM#90-A-58C
MIDDLETOWN DATA CENTER, LLC
#20180010765
ZONED: M1
TM#90-A-58A
FISHER SCIENTIFIC
COMPANY, LLC
DB 957 PG 951
ZONED: M1
10'
5'
D
D
C
A
C
A
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS8000.dwg PLOTTED: 9/30/2025 12:47 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTFIRE LANE MARKING & SIGNAGE PLANCS8000
SHEET 15 OF 19 2025-09-08 00 30'60'
GRAPHIC SCALE 1"=30'
U.S. ROUTE 11 - VALLEY PIKE
(VARIABLE WIDTH R/W)
TM#90-A-58B
FISHER SCIENTIFIC
COMPANY, LLC
#20170009047
ZONED: M1
TM#90-A-58C
MIDDLETOWN DATA CENTER, LLC
#20180010765
ZONED: M1
TM#90-A-58A
FISHER SCIENTIFIC
COMPANY, LLC
DB 957 PG 951
ZONED: M1
10'
5'
9
22
8
19 19 25
VALLEY PIKE
US RTE. 11
VARIABLE WIDTH R/W
PR. 30" CONC. SLAB
FOR LIGHT POLE
LIMITS
OF WP-2
5 PR. HC
PRKG SIGNS
CG-6
CG-6
CG-6
CG-6
CG-6 CG-6CG-6CG-6CG-6CG-6RCG-6R
PR. STOP
SIGN
Luminaire Schedule
Symbol Qty Label Arrangement Description LLF Luminaire
Lumens
Luminaire
Watts
Total
Watts
3 S2 Back-Back LSI 2/MRM-LED-18L-SIL-5W-40-70CRI, RTP-B3-S11G-25-D180-25SRTBC, 25' AFG0.900 18633 135 810
Calculation Summary
Label CalcType Units Avg Max Min Avg/Min Max/Min
GRADE Illuminance Fc 2.16 5.3 0.1 21.60 53.00
PROPERTY LINE Illuminance Fc 0.00 0.0 0.0 N.A.N.A.
PARKING Illuminance Fc 2.55 5.3 0.9 2.83 5.89
S2
S2
S2
0.
1
0.1
0.1
0.2
0.1
0.1
0.
2
0.
3
0.
5
0.6
0.
1
0.2
0.3
0.4
0.6
0.8
0.9
0.1
0.2
0.
3
0.
4
0.
6
0.
8
1.0
1.
1
1.
1
0.1
0.
2
0.3
0.4
0.6
0.8
1.
0
1.
2
1.4
1.5
1.3
1.1
0.3
0.4
0.
6
0.
8
1.0
1.2
1.6
2.0
2.1
1.
8
1.
4
1.
1
0.9
1.0
1.
2
1.
5
2.1
3.0
3.3
2.6
1.9
1.5
1.2
1.0
1.2
1.3
1.5
2.
0
2.
7
4.
1
4.
7
3.7
2.8
2.1
1.
5
1.2
1.0
1.
4
1.5
1.7
2.0
2.8
3.9
4.8
5.0
4.8
4.0
2.
7
1.8
1.3
1.
1
1.4
1.7
1.8
2.
0
2.
4
3.3
4.
6
5.
1
5.1
4.9
4.
1
2.7
1.8
1.3
1.0
1.
5
1.
8
2.0
2.1
2.4
3.0
3.7
4.5
5.
2
4.4
3.
0
2.
1
1.5
1.
1
0.
9
1.2
1.6
1.9
2.
1
2.
1
2.
3
2.
5
2.8
3.5
4.
2
3.
5
2.4
1.
7
1.2
1.0
0.7
1.
0
1.
2
1.
6
2.
0
2.3
2.3
2.3
2.3
2.4
2.8
3.
1
2.7
2.
0
1.5
1.1
0.
9
1.1
1.3
1.8
2.4
2.
9
2.
8
2.
5
2.
3
2.
3
2.
4
2.
4
2.2
1.
8
1.
4
1.0
0.7
1.
2
1.
3
1.
6
2.
2
3.1
4.
0
3.7
3.0
2.7
2.4
2.3
2.2
2.
0
1.7
1.3
1.
0
1.3
1.5
1.7
2.0
2.7
3.
9
5.
1
4.8
4.
1
3.
4
2.7
2.
3
2.1
2.0
1.
7
1.2
1.6
1.
8
2.1
2.
7
3.7
4.8
5.2
5.1
5.1
3.9
2.8
2.2
1.9
1.8
1.4
1.
6
1.
9
2.1
2.4
3.
0
4.2
5.
2
5.
2
5.1
4.
5
3.
3
2.
4
1.
9
1.6
1.4
1.
1
1.3
1.8
2.
1
2.3
2.5
2.
9
3.5
4.
1
4.8
5.1
3.7
2.5
1.9
1.5
1.3
1.1
1.
4
1.8
2.2
2.5
2.7
2.7
2.8
3.
1
3.
8
4.
0
3.
1
2.1
1.
6
1.
3
1.1
1.1
1.4
1.9
2.
6
3.
1
3.
1
2.8
2.7
2.7
3.0
3.0
2.5
2.0
1.5
1.2
0.
9
1.1
1.
5
2.1
3.1
4.1
4.0
3.
3
2.
9
2.
7
2.
6
2.
5
2.2
1.
8
1.
4
1.1
0.
9
1.2
1.7
2.
4
3.
6
5.1
5.0
4.3
3.7
3.0
2.5
2.3
2.1
1.8
1.3
0.8
1.1
1.
4
2.0
3.1
4.5
5.0
5.
2
5.
3
4.3
3.
1
2.
4
2.
1
1.
9
1.
6
0.
9
1.2
1.5
2.
2
3.3
4.
7
5.
0
5.0
4.
7
3.5
2.6
2.1
1.8
1.6
1.3
0.9
1.1
1.
4
1.9
2.6
3.3
4.2
4.8
3.
7
2.
5
1.9
1.6
1.
4
1.
2
0.
9
1.1
1.4
1.
7
2.
2
2.
9
3.4
2.8
2.0
1.5
1.2
1.1
1.1
1.3
1.5
2.0
2.2
2.
0
1.5
1.2
1.
0
0.
8
1.
0
1.
1
1.
4
1.5
1.4
1.
2
1.0
0.8
1.0
1.1
1.1
1.0
0.8
0.9
1.
0
0.
0
0.
0
0.0 0.0
0.
0
0.0 0.0 0.0 0.0
0.
0
0.0 0.0 0.0
0.
0
0.0 0.0 0.0 0.0
0.
0
0.0 0.0 0.0
0.
0
0.0 0.0 0.0
0.
0
0.
0
0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0
0.
0
0.0 0.0 0.0
0.
0
0.0 0.0 0.0 0.0
0.
0
0.0 0.0 0.0
0.
0
0.0 0.00+000+50727
728726
727
726
72
5
72
4
724
7
2
3
722
725
725
722
721720
719 718
717
716
722
722
721
720 719
722
721
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD = 1.63 ACRES
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS8100.dwg PLOTTED: 9/30/2025 12:47 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTPHOTOMETRIC PLANCS8100
SHEET 16 OF 19 2025-09-08 00 30'60'
GRAPHIC SCALE 1"=30'
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS9100.dwg PLOTTED: 9/30/2025 12:47 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTSWM NARRATIVE, COMPLIANCE, & COMPUTATIONSCS9100
SHEET 17 OF 19 2025-09-08 4 inch
U.S. ROUTE 11 - VALLEY PIKE
(VARIABLE WIDTH R/W)
TM#90-A-58B
FISHER SCIENTIFIC
COMPANY, LLC
#20170009047
ZONED: M1
TM#90-A-58C
MIDDLETOWN DATA CENTER, LLC
#20180010765
TM#90-A-58A
FISHER SCIENTIFIC
COMPANY, LLC
DB 957 PG 951
ZONED: M1
10'
5'
PI-2 - EXISTING
0.62 ACRES
IMP=0.06 ACRES
PI-3 - EXISTING
0.33 ACRES
IMP=0.09 ACRES
PI-1 - EXISTING
1.23 ACRES
IMP=0.38 ACRES
U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS9200.dwg PLOTTED: 9/30/2025 12:48 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTPRE-DEVELOPMENT DRAINAGE MAPCS9200
SHEET 18 OF 19 2025-09-08 00 30'60'
GRAPHIC SCALE 1"=30'
U.S. ROUTE 11 - VALLEY PIKE
(VARIABLE WIDTH R/W)
TM#90-A-58B
FISHER SCIENTIFIC
COMPANY, LLC
#20170009047
ZONED: M1
TM#90-A-58A
FISHER SCIENTIFIC
COMPANY, LLC
DB 957 PG 951
ZONED: M1
10'
5'
9
22
8
19 19 25
VALLEY PIKE
US RTE. 11
VARIABLE WIDTH R/W
5 PR. HC
PRKG SIGNS
CG-6
CG-6
CG-6
CG-6
CG-6 CG-6CG-6CG-6CG-6CG-6RCG-6R
PR. STOP
SIGN
727
728726
727
726
72
5
72
4
724
7
2
3
722
725
725
722
721720
719 718
717
716
722
722
721
720 719
722
721 0+000+50DA-2
0.43 AC.
DA-11
0.21 AC.
DA-3
0.24 AC.
DA-4
0.09 AC.
DA-4A
0.06 AC.
DA-6
0.13 AC.
PI-2 - POST
0.34 AC.
IMP=0.06 AC.
PI-3 - POST
0.16 AC.
IMP=0.11 AC.
DA-5
0.03 AC.
PI-1 - POST
UNDETAINED - 0.66 AC.
IMP=0.39 AC.
ROUTED - 1.20 AC.
IMP=0.77 AC.U:\Accounts\HITTC\HITTC25002 - Thermo Fisher MDT Dry Room\DESIGN\_SHEETS\CS9300.dwg PLOTTED: 9/30/2025 12:48 PM, BY: Britney Ford PLOTSTYLE: Pennoni NCS.stb BYNO.DATEREVISIONSHITTC25002
AS NOTED
TEAM
2025-08-25
MMAAPPROVED BY
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NOT FOR BID OR CONSTRUCTION FISHER SCIENTIFIC COMPANY, LLC300 INDUSTRY DRIVE | PITTSBURG, PA 15275THERMO FISHER PARKING EXPANSIONSITE PLANTM#90-A-58B | VALLEY PIKEBACK CREEK DISTRICTPOST-DEVELOPMENT DRAINAGE MAPCS9300
SHEET 19 OF 19 2025-09-08 00 30'60'
GRAPHIC SCALE 1"=30'