November 3, 2025
Mike Artz (via email: martz@pennoni.com)
Pennoni Associates, Inc.
117 E. Piccadilly Street, Suite 200
Winchester, Virginia 22601
Dear Mr. Artz:
Re: Review Comments for Site Plan #45-25 – Fisher Scientific Parking Expansion
Property Identification Number (PIN): 90-A-58B
The Planning Staff has reviewed the above-referenced minor site plan to determine if
administrative approval can be granted. At this time, administrative approval cannot be
granted. This site plan cannot be approved until the issues in this letter, as well as all issues of
the other review agencies, have been adequately addressed. Please review Staff’s comments
listed below and then prepare a revised site plan which adequately address each concern.
Review Comments
1. Boundary Line Adjustment. Parking is not a permitted use as a primary use for the
parcel. A boundary line adjustment with the primary use that the parking serves is
required. Update all calculations, green space requirements, and other ordinance
requirements based on the newly formed parcel.
2. Power of Attorney. The original, signed and sealed, Power of Attorney is required.
3. Cover Sheet. The following items should be made:
• Site Plan Reference. Add the Site Plan Reference number #45-25.
• North Arrow. Ensure that a North arrow is on all relevant sheets.
• Zoning Administrator Signature Box. The Zoning Administrators signature
box is the correct term to apply to the county approval box.
4. Site Plan.
• Obstructions. Utility poles shall not be permitted within any parking space.
Any structure located in a parking lot shall be surrounded on all sides abutting
spaces or aisles by a six-inch concrete curb. The structure shall be separated
from the curb by a distance of three feet. (§165-202.01(D)(11)).
• Adjacent Parcels. Identify the relevant zoning and current use for the adjacent
parcels on C2.00.
• Parking Surface Material. Identify the parking surface material. The legend
identifies some materials but there is no correlation to the parking lot material.
5. Landscaping and Boundary Lot Survey. Address landscaping and parking
requirements on the overall area of the new parcel and identify the boundaries of the
parcel.
• Interior and Perimeter Landscaping. Shade trees required based on 2000
square feet of parking area are rounded up, not down. Eleven (11) trees will
be required based on the proposed 33,077 square feet of parking area.
6. Lighting Plan.
• Height. Lighting fixtures, including mounting base, shall not be more than 25
feet above finished grade. (165-201-07(B)(3)). Light fixtures located in a
parking lot shall be surrounded on all sides, abutting spaces or aisles by a six-
inch curb. The structure shall be separated from the curb by a distance of three
feet. (165-202.01(D)(11)).
• Notes. Add a note specifying that all site lighting will be in conformance with
§165-201.07 and be full cutoff, fully downcast and shielded.
7. Agency Approvals. Comment sheets (approvals) are required from the following
agencies: the Frederick County Inspections Department, the Frederick County Fire
Marshal, the Virginia Department of Transportation (VDOT), Frederick Water, the
Frederick County Engineer (Public Works), and Frederick County Geographic
Information Systems.
Additional Comments may be provided on subsequent submissions.
After you have revised the site plan, please resubmit three (3) hard copies and (1)
digital copy so that Staff may verify the information contained on the plan addresses
the above comments, as well as other agency comments that you may have received.
Staff will also need all approved review agency comments, at least three (3) copies of
the final plan set and a digital (PDF) copy of the approval. Do not hesitate to contact
me if you have any questions or concerns regarding this letter. Thank you for your
consideration.