312 West Main Street, Luray, VA 22835 | P 540-743-9227 | F 540-743-6118 | www.raceyengineering.com
March 23, 2026
Racey Project Number: 10374
Site Plan Reference Number: 25-25
Project Name: 1771 Old Firehouse Lane
Subject: 1st Submittal Comment Response Letter
Frederick County Planning and Zoning
We have revised the above referenced plan based on the review comments dated October 15, 2025. See
below your comments and our responses in Italics to the comments.
Review County Comments:
Cover Sheet: The following revisions should be made to sheet C200:
• Surface Material: Describe the surface material of the existing & proposed new parking area.
§165.202.01(D)(1) states that “parking lots shall be paved with concrete, bituminous concrete or
similar materials. Such surface materials shall provide a durable, dust and gravel-free, hard surface.”
o Note: The Zoning Administrator may allow for the use of other hard-surface materials for
parcels located outside of the Sewer and Water Service Area if the site plan provides for
effective stormwater management and efficient maintenance. In such cases, parking lots shall
be paved with a minimum of double prime-and-seal treatment or an equivalent surface per
§165.202.01(D)(1)(a). (repeat)
Response: The owner has now accepted to double prime-and-seal treat the existing parking area if
the county is acceptable to this surface material. The plan has been updated to reflect this surface
material and specifications for its installation are included.
• Screening Fence: Note # 11 states “proposed screen fence.” Add detail describing the type of fence
– it must be 6’ tall, completely opaque, and not made of chain link fencing with slats per §165-
201.10. A board-on-board fence, for example, would meet this requirement. (repeat)
Response: The existing school on Tax Map #52-9-A is already screened by an existing board fence.
The owner has informed us that this fence has been looked at previously by Wyatt Pearson
during a past site visit. According to the owner, he was told that the existing fence was
adequate for screening for outdoor storage.
The owner has now accepted to provide the required additional screening. The following
has been added to the plan:
• board screening fence to match the existing board fence that screens the school
(TM#52-9-A) to screen TM 52-A-285. A screening Fence Specification has been
provided to detail the construction standards of this fence.
• Old Firehouse Ln and the rest of the surrounding properties will be screened by two
rows (staggered) of Green Giants (Thuja Occidentalis) evergreen trees. Number of
trees, spacing requirements, and minimum planting height have been added to the
plan sheet.
171 Firehouse lane Site Plan
Site Plan #29-25 Comment Response Letter
Page 2 of 3
• Use of Existing House: Identify the use of the existing house (office for employees only, office for
customers, etc.) and address parking spaces, accessible parking spaces, and pedestrian access to
the main entrance accordingly. (repeat)
Response: Hours of operation are limited to 6:00 am to 8:00 pm as listed in the CUP #03-24
additional conditions. This office will be for employees only and will not accept walk in
customers.
The owner has now accepted to provide an accessible parking space in the existing driveway.
This has been added to the plan sheet.
The designated pedestrian route has been shown. See note #23
• Future Parking: Future parking that requires a new submission will need to be removed from the
plan. You may include the future parking in this submission and address all ordinance requirements
or remove the future parking from this site plan.
Response: The owner has agreed to remove the proposed parking from this plan.
Virginia Department of Health Comments:
• The Frederick County Health Department cannot make a favorable comment for the proposed uses.
An AOSE /PE will need to make comments to the health department on the existing sewage system
and well verifying they are adequate for the proposed use.
Response: We made follow-up submittal to the Virginia Department of Health on 3/18/2026 and
received the following comments by email on 3/19/2026
• The well needs to be submitted to the Offices of Drinking Water for determination of if they
will need to regulate the well.
Response: A request letter is being written and will be sent, and FC VDH will be copied on
the correspondence.
• A repair plan and permit application needs to be submitted to the Virginia Department of
Health for the septic tank, distribution box, and header line repairs before they can provide
favorable comment.
Response: The plan has been annotated to show the items needing repair “to be replaced
in kind by a certified installer.” A repair permit application on behalf of the owner will be
submitted to VDH.
171 Firehouse lane Site Plan
Site Plan #29-25 Comment Response Letter
Page 3 of 3
Please find attached 171 Old Fire House Lane Site Plan Third Submittal for your review. If you have any
questions regarding the responses to these comments, please feel free to contact me personally. Thank you.
Sincerely,
Racey Engineering, PLLC
Berlin B. Neff
Civil Engineer
Attachments: 171 Old Fire House Lane Site Plan dated 3/23/26