Loading...
HomeMy WebLinkAboutCorrespondence 312 West Main Street, Luray, VA 22835 | P 540-743-9227 | F 540-743-6118 | www.raceyengineering.com October 02, 2024 Racey Project Number: 10374 Site Plan Reference Number: 25-25 Project Name: 1771 Old Firehouse Lane Subject: 1st Submittal Comment Response Letter Frederick County Planning and Zoning We have revised the above referenced plan based on the review comments dated October 2, 2025. See below your comments and our responses in Italics to the comments. Review County Comments: 1) Cover Sheet: The following revisions should be made to sheet C200: • Reference Number: Add new site plan reference #29-25. Response: Added to the Project Site Summary section. • Signature Block: Update the signature block from “Approved by the County Administrator” to “Approved by the Frederick County Zoning Administrator.” Response: Revised accordingly. • Drainfield: Show the location of the drainfield. Response: The drainfield location has been added as requested. • Surface Material: Describe the surface material of the existing & proposed new parking area. §165.202.01(D)(1) states that “parking lots shall be paved with concrete, bituminous concrete or similar materials. Such surface materials shall provide a durable, dust and gravel-free, hard surface.” o Note: The Zoning Administrator may allow for the use of other hard-surface materials for parcels located outside of the Sewer and Water Service Area if the site plan provides for effective stormwater management and efficient maintenance. In such cases, parking lots shall be paved with a minimum of double prime-and-seal treatment or an equivalent surface per §165.202.01(D)(1)(a). Response: The surface materials have been described by the existing cover surface type using the hatch legend. We are requesting to keep the existing gravel surface as is considering the roadway used to access this property is gravel. The future gravel lot surface would be prescribed at the time in which the plan is made and will be submitted for review as part of the permit review process. • Concrete Bumpers: It appears that concrete bumpers/wheel stops are utilized for each parking space. Add a label. These are permitted to be used instead of curb and gutter per §165.202.01(D)(3)(b). Response: Concrete parking stops (Bumpers) are shown and proposed for the existing parking area and will be proposed parking area. • Screening Fence: Note # 11 states “proposed screen fence.” Add detail describing the type of fence – it must be 6’ tall, completely opaque, and not made of chain link fencing with slats per §165-201.10. A board-on-board fence, for example, would meet this requirement. Response: The Buffer and Screening note has been updated to provide additional information for the fence requirement. • Use of Existing House: Identify the use of the existing house (office for employees only, office for customers, etc.) Response: The existing house is being used as the office for this business. The site notes have been updated accordingly. 171 Firehouse lane Site Plan Site Plan #29-25 Comment Response Letter Page 2 of 3 Frederick Couty Fire and Rescue Comments: Approved with Conditions • A Fire Apparatus Access Road (SFP2021, Section 503), with a minimum width of 20 feet, shall be maintained to all occupied structures. Response: The Fire Apparatus Access Route has been annotated with an arrowed line and a callout added to the site notes table for reference. We have also provided a Fire Access Note to call out that this route is to be maintained and left open at all times. Virginia Department of Health Comments: • The Frederick County Health Department cannot make a favorable comment for the proposed uses. An AOSE /PE will need to make comments to the health department on the existing sewage system and well verifying they are adequate for the proposed use. Response: An evaluation is being scheduled to determine the condition and adequacy of the drainfield and well. The records available on the drainfield are limited, and an on-site investigation may be required. Once the report has been completed it will be forwarded to the Department of Health for Review. Frederick County Inspections Department Comments: • The office building and site shall comply with the current Virginia Construction Code (VCC, Virginia Existing Building Code (VEBC) and ICC A117.1 Response: Understood. • Necessary permits shall be obtained prior to any modifications or construction of site and structures. Response: Understood. Frederick County Inspections Department Comments: • Upon review of the site plan dated August 12, 2025, we recommend approval of the subject plan. A land disturbance permit will not be required. (<10,000 square feet disturbed). Response: Understood Virginia Department of Transportation Comments: • The provided site plan, 171 Old Fire Houe Lane, Minor Site Plan has been reviewed and appears to be satisfactory. VDOT has no other Comments at this time. Response: Understood 171 Firehouse lane Site Plan Site Plan #29-25 Comment Response Letter Page 3 of 3 Please find attached 171 Old Fire House Lane Site Plan Second Submittal for your review. If you have any questions regarding the responses of these comments, please feel free to contact me personally. Thank you. Sincerely, Racey Engineering, PLLC Berlin B. Neff Civil Engineer Attachments: 171 Old Fire House Lane Site Plan dated 10/02/25