HomeMy WebLinkAbout5-12-2026 Reina_Hamayama_260508_Costco - Winchester VA - Civil Site PlansCC CCCC CC CC CC CC CC CC CC CC CC CCCCCCCCCCCCCCPROP 5' S I DEW ALK PROP 5' S I DEW ALK PROP 5' SIDEW A L K PROP 5' S I D E W A L KCOSTELLO DRIVEFR O N T R O Y A L P I K E - U . S . R O U T E 5 2 2OWNER / APPLICANTCOSTCO WHOLESALEADDRESS: 999 LAKE DRIVE ISSAQUAH, WA 98027CONTACT: NICK TOSEPHONE: (703) 855 - 4006EMAIL: NTOSE@COSTCO.COMPROPOSED SITE PLANDOCUMENTS #18-25LOCATION OF SITE251 FRONT ROYAL PIKE SHAWNEE MAGISTERIAL DISTRICTFREDERICK COUNTY, WINCHESTER, VIRGINIA 22602PIN #: 64-8-1 AND 64-8-2FORCONTACT: SHEILA NALE, PE703-709-9500PREPARED BYGENERAL NOTE:IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THIS PROJECTWORK SCOPE PRIOR TO THE INITIATION OF CONSTRUCTION. SHOULD THE CONTRACTOR FIND A CONFLICT WITH THE DOCUMENTS RELATIVE TOTHE SPECIFICATIONS OR APPLICABLE CODES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PROJECT ENGINEER OF RECORD INWRITING PRIOR TO THE START OF CONSTRUCTION. FAILURE BY THE CONTRACTOR TO NOTIFY THE PROJECT ENGINEER SHALL CONSTITUTEACCEPTANCE OF FULL RESPONSIBILITY BY THE CONTRACTOR TO COMPLETE THE SCOPE OF THE WORK AS DEFINED BY THE DRAWINGS AND INFULL CONFORMANCE WITH LOCAL REGULATIONS AND CODES.SHEET INDEXSHEET TITLESHEET NUMBERCOVER SHEETC-101GENERAL NOTES AND LEGENDC-102 - C-103ALTA/NSPS LAND TITLE SURVEYC-201 - C-203OVERALL EXISTING CONDITIONS/DEMOLITION PLANC-204EXISTING CONDITIONS/DEMOLITION PLANC-205 - C-209OVERALL SITE PLANC-301SITE PLANC-302 - C-306OVERALL TRUCK TURN PLANC-307ENTRANCE EXHIBITC-308ENTRANCE PROFILESC-309OVERALL FIRE MARSHAL PLANC-310FIRE MARSHAL PLANC-311 - C-312OVERALL GRADING PLANC-401GRADING PLANC-402 - C-407OVERALL UTILITY PLANC-501UTILITY PLANC-502 - C-506SANITARY PROFILESC-601 - C-602WATER PROFILESC-603 - C-604STORM PROFILESC-605 - C-616STORM COMPUTATIONSC-617 - C-618FRONT ROYAL PIKE TAPER LANEC-701SIGHT DISTANCE PROFILESC-702 - C-705OVERALL EROSION AND SEDIMENT CONTROL PLAN PHASE IC-801EROSION AND SEDIMENT CONTROL PLAN PHASE IC-802 - C-803OVERALL EROSION AND SEDIMENT CONTROL PLAN PHASE IIC-804EROSION AND SEDIMENT CONTROL PLAN PHASE IIC-805 - C-806EROSION AND SEDIMENT CONTROL NOTES AND DETAILSC-807 - C-809PRE DEVELOPMENT DRAINAGE AREA MAPC-901POST DEVELOPMENT DRAINAGE AREA MAPC-902BMP MAPC-903VRRM SPREADSHEETC-904STORMWATER MANAGEMENT PLANC-905HYDROCAD ROUTINGSC-906 - C-909STORMWATER MANAGEMENT DETAILSC-910 - C-919STORMWATER FYIC-920 - C-921CONSTRUCTION DETAILSC-1001 - C-1003CORRESPONDENCEC-1004PHOTOMETRIC PLAN - FYIC-1005WATER MODELC-1006OVERALL LANDSCAPE PLANL-101LANDSCAPE PLANL-102 - L-106LANDSCAPE COMPLIANCEL-107LANDSCAPE NOTES AND DETAILSL-108TOTAL SHEETS104C-101COVERSHEETLOCATION MAPSCALE: 1" = 1,000'SOURCE: FREDERICK COUNTY GIS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA220135.00-0A----->LAYOUT: C-101 COVER SHEETYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-CNDSPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026PROJECT NARRATIVE:THE PROPOSED SUBJECT PROPERTY IS LOCATED ON AN EXISTINGPARCEL HOUSING AN EXISTING WAREHOUSE AND GAS STATION, ASWELL AS AN EXISTING VACANT PARCEL. THE PROPERTY FRONTS ONFRONT ROYAL PIKE (ROUTE 522) TO THE EAST AND COSTELLO DRIVETO THE SOUTH. THE PURPOSE OF THIS PROJECT IS TO REMOVE A2,833 SQUARE FOOT GAS CANOPY AND CONSTRUCT A 20,709 SQUAREFOOT ADDITION TO A RETAIL BUILDING AND A 8,127 SQUARE FOOT GASCANOPY WITH ASSOCIATED LOADING AREAS, PARKING AREAS,UTILITIES, AND LANDSCAPE IMPROVEMENTS. THE TOTAL DISTURBEDAREA FOR THE CONSTRUCTION ACTIVITY IS ANTICIPATED TO BE 12.85ACRES.REFERENCES¨ORIGINAL COSTCO SITE PLAN TITLED: 'PRICE COSTCO, FREDERICK COUNTY, VIRGINIA, SHAWNEE MAGISTERIAL DISTRICT,PREPARED BY: GILBERT W. CLIFFORD &ASSOCIATES, INC. DATED: 12/23/94¨ALTA/NSPS LAND TITLE SURVEYTITLED: "COSTCO WINCHESTER,SHAWNEE MAGISTERIAL DISTRICT,FREDERICK COUNTY, VIRGINIA"PREPARED BY: BOHLERPROJECT NUMBER: NJA220135DATED: 02/14/2023¨GEOTECHNICAL REPORTTITLED: "PROPOSED COSTCO FUEL AND BUILDINGEXPANSION - WINCHESTER"PREPARED BY: TERRACONDATED: 05/16/2023TERRACON PROJECT No: JD235031¨PREVIOUSLY APPROVED SITE PLANS#19-94, #17-98, #16-04, #42-05, #38-20GOVERNING AGENCIES¨PLANNING, ZONING AGENCY FREDERICK COUNTY DEPARTMENT OF PLANNINGAND DEVELOPMENT107 N KENT STREET WINCHESTER, VA 22601 PHONE: (540) 665-5651¨BUILDING DEVELOPMENTFREDERICK COUNTY BUILDING INSPECTIONS107 N KENT STREET WINCHESTER, VA 22601PHONE: (540) 665-5650¨FIRE DEPARTMENTFREDERICK COUNTY FIRE & RESCUE 1080 COVERSTONE DRIVE WINCHESTER, VA 22602 PHONE: (540) 665-5618ROW JURISDICTION¨TRAFFIC, STORMWATER, WATER &SEWERFREDERICK COUNTY PUBLIC WORKS 107 N KENT STREET WINCHESTER, VA 22601 PHONE: (540) 665-5643UTILITIES¨FREDERICK WATER FREDERICK COUNTY SANITATION AUTHORITY315 TASKER ROAD STEPHENS CITY, VA 22655 PHONE: (540) 868-1061¨WASHINGTON GAS 350 HILLANDALE LANEWINCHESTER, VA 22602PHONE: (540)869-1111¨SHENANDOAH VALLEY ELECTRICCOOPERATIVE3463 VALLEY PIKEWINCHESTER, VA 22602PHONE: (540) 434-2200¨VERIZON2021 SOUTH PLEASANT VALLEY ROADWINCHESTER, VA 22601PHONE: 804-608-5640* THE ABOVE REFERENCED DOCUMENTS ARE INCORPORATED BY REFERENCE AS PART OF THESE PLANS, HOWEVER, BOHLER ENGINEERING DOES NOTCERTIFY THE ACCURACY OF THE WORK REFERENCED OR DERIVED FROM THESE DOCUMENTS, BY OTHERS.PLAN REFERENCES AND CONTACTSAPPROVED BY THE FREDERICKCOUNTY ZONING ADMINISTRATORSIGNATUREAPPROVAL DATENOTE: SITE PLAN VALID FOR FIVE (5) YEARS FROM APPROVAL DATE.Pursuant to 9VAC-870-55, I hereby certify that to the best of my knowledge and belief the stormwatermanagement facilities shown on these record drawings have been constructed in accordance with the approvedplans and specifications.NameSignatureVirginia LicenseDate"Certify means to state or declare a professional opinion based on sufficient and appropriate onsite inspections,material tests, as-built data, and information provided by other professionals and the contractor, conducted duringor after construction.NOTE: UPON PROJECT COMPLETION, FREDERICK COUNTY REQUIRES CERTIFIED AS-BUILTDRAWINGS AND CONSTRUCTION DOCUMENTATION CONFIRMING THAT ALL STORMWATERFACILITIES HAVE BEEN CONSTRUCTED IN ACCORDANCE WITH THE APPROVED PLANS ANDTHE MANUFACTURER’S RECOMMENDATIONS.SHEILA NALE065903 DEMOLITION NOTES(Rev. 1/2023)1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACTDOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLYCOMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITYWITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES.2.THE CONTRACTOR MUST CONDUCT DEMOLITION/REMOVALS ACTIVITIES IN SUCH A MANNER AS TO ENSURE MINIMUMINTERFERENCE WITH ROADS, STREETS, SIDEWALKS, WALKWAYS, AND ALL OTHER ADJACENT FACILITIES. THE CONTRACTORMUST OBTAIN ALL APPLICABLE PERMITS FROM THE APPROPRIATE GOVERNMENTAL AUTHORITY(IES) PRIOR TO THECOMMENCEMENT OF ANY ROAD OPENING OR DEMOLITION ACTIVITIES IN OR ADJACENT TO THE RIGHT-OF-WAY.3.WHEN DEMOLITION-RELATED ACTIVITIES IMPACT ROADWAYS AND/OR ROADWAY RIGHT-OF-WAY, THE CONTRACTOR MUSTPROVIDE TRAFFIC CONTROL AND GENERALLY ACCEPTED SAFE PRACTICES IN CONFORMANCE WITH THE CURRENT FEDERALHIGHWAY ADMINISTRATION "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" (MUTCD), AND THE FEDERAL, STATE, AND LOCALREGULATIONS.4.THE DEMOLITION (AND/OR REMOVALS) PLAN IS INTENDED TO PROVIDE GENERAL INFORMATION AND TO IDENTIFY ONLYCONDITIONS REGARDING ITEMS TO BE DEMOLISHED, REMOVED, AND/OR TO REMAIN.A.THE CONTRACTOR MUST ALSO REVIEW ALL CONSTRUCTION DOCUMENTS AND INCLUDE WITHIN THE DEMOLITION ACTIVITIESALL INCIDENTAL WORK NECESSARY FOR THE CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.B.THIS PLAN IS NOT INTENDED TO AND DOES NOT PROVIDE DIRECTION REGARDING THE MEANS, METHODS, SEQUENCING,TECHNIQUES AND PROCEDURES TO BE EMPLOYED TO ACCOMPLISH THE WORK. ALL MEANS, METHODS, SEQUENCING,TECHNIQUES AND PROCEDURES TO BE USED MUST BE IN STRICT ACCORDANCE AND CONFORMANCE WITH ALL STATE,FEDERAL, LOCAL, AND JURISDICTIONAL REQUIREMENTS. THE CONTRACTOR MUST COMPLY WITH ALL OSHA AND OTHERSAFETY PRECAUTIONS NECESSARY TO PROVIDE A SAFE WORK SITE FOR THE CONTRACTOR AND THE PUBLIC.5.THE CONTRACTOR MUST PROVIDE ALL "METHODS AND MEANS" NECESSARY TO PREVENT MOVEMENT, SETTLEMENT, ORCOLLAPSE OF EXISTING STRUCTURES, AND ANY OTHER IMPROVEMENTS THAT ARE REMAINING ON OR OFF SITE. THECONTRACTOR, AT THE CONTRACTOR'S SOLE COST, MUST REPAIR ALL DAMAGE TO ALL ITEMS AND FEATURES THAT ARE TOREMAIN. CONTRACTOR MUST USE NEW MATERIAL FOR ALL REPAIRS. CONTRACTOR'S REPAIRS MUST INCLUDE THERESTORATION OF ALL ITEMS AND FEATURES REPAIRED TO THEIR PRE-DEMOLITION CONDITION, OR BETTER. CONTRACTOR MUSTPERFORM ALL REPAIRS AT THE CONTRACTOR'S SOLE EXPENSE.6.THE PROFESSIONAL OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR JOB SITE SAFETY OR SUPERVISION. THECONTRACTOR MUST PROCEED WITH THE DEMOLITION IN A SYSTEMATIC AND SAFE MANNER, COMPLYING WITH ALL OSHAREQUIREMENTS, TO ENSURE PUBLIC AND CONTRACTOR SAFETY AND SAFETY TO ALL PROPERTY ON THE SITE OR ADJACENT ORNEAR TO THE SAME.7.THE CONTRACTOR IS RESPONSIBLE FOR JOB SITE SAFETY, WHICH MUST INCLUDE, BUT IS NOT LIMITED TO, THE INSTALLATIONAND MAINTENANCE OF BARRIERS, FENCING, OTHER APPROPRIATE AND/OR NECESSARY SAFETY FEATURES AND ITEMSNECESSARY TO PROTECT THE PUBLIC FROM AREAS OF CONSTRUCTION AND CONSTRUCTION ACTIVITIES. THE CONTRACTORMUST SAFEGUARD THE SITE AS NECESSARY TO PERFORM THE DEMOLITION IN SUCH A MANNER AS TO PREVENT THE ENTRY OFALL UNAUTHORIZED PERSONS AT ANY TIME, TO OR NEAR THE DEMOLITION AREA.8.PRIOR TO THE COMMENCEMENT OF ANY SITE ACTIVITY AND ANY DEMOLITION ACTIVITY, THE CONTRACTOR MUST, IN WRITING,RAISE ANY QUESTIONS CONCERNING THE ACCURACY OR INTENT OF THESE PLANS AND/OR SPECIFICATIONS, ALL CONCERNS ORQUESTIONS REGARDING THE APPLICABLE SAFETY STANDARDS, AND/OR THE SAFETY OF THE CONTRACTOR AND/OR THIRDPARTIES IN PERFORMING THE WORK ON THIS PROJECT. ANY SUCH CONCERNS MUST BE CONVEYED TO THE PROFESSIONAL OFRECORD AND BOHLER, IN WRITING AND MUST ADDRESS ALL ISSUES AND ITEMS RESPONDED TO, BY THE PROFESSIONAL OFRECORD AND BY BOHLER, IN WRITING. ALL DEMOLITION ACTIVITIES MUST BE PERFORMED IN ACCORDANCE WITH THEREQUIREMENTS OF THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS,RULES, REQUIREMENTS, STATUTES, ORDINANCES AND CODES.9.THE CONTRACTOR MUST BECOME FAMILIAR WITH THE APPLICABLE UTILITY SERVICE PROVIDER REQUIREMENTS AND ISRESPONSIBLE FOR ALL COORDINATION REGARDING UTILITY DEMOLITION AND/OR DISCONNECTION AS IDENTIFIED OR REQUIREDFOR THE PROJECT. THE CONTRACTOR MUST PROVIDE THE OWNER WITH WRITTEN NOTIFICATION THAT THE EXISTING UTILITIESAND SERVICES HAVE BEEN TERMINATED, REMOVED AND/OR ABANDONED IN ACCORDANCE WITH THE JURISDICTION AND UTILITYCOMPANY REQUIREMENTS AND ALL OTHER APPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES.10.PRIOR TO COMMENCING ANY DEMOLITION, THE CONTRACTOR MUST:A.OBTAIN ALL REQUIRED PERMITS AND MAINTAIN THE SAME ON SITE FOR REVIEW BY THE PROFESSIONAL OF RECORD ANDALL PUBLIC AGENCIES WITH JURISDICTION THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK, AND DEMOLITIONWORK.B.NOTIFY, AT A MINIMUM, THE MUNICIPAL ENGINEER, DESIGN ENGINEER, AND LOCAL SOIL CONSERVATION JURISDICTION, ATLEAST 72 BUSINESS HOURS PRIOR TO THE COMMENCEMENT OF WORK.C.INSTALL THE REQUIRED SOIL EROSION AND SEDIMENT CONTROL MEASURES PRIOR TO SITE DISTURBANCE, AND MAINTAINSAID CONTROLS UNTIL SITE IS STABILIZEDD.IN ACCORDANCE WITH STATE LAW, THE CONTRACTOR MUST CALL THE STATE ONE-CALL DAMAGE PROTECTION SYSTEM FORUTILITY MARK OUT, IN ADVANCE OF ANY EXCAVATION.E.LOCATE AND PROTECT ALL UTILITIES AND SERVICES, INCLUDING BUT NOT LIMITED TO GAS, WATER, ELECTRIC, SANITARYAND STORM SEWER, TELEPHONE, CABLE, FIBER OPTIC CABLE, ETC. WITHIN AND ADJACENT TO THE LIMITS OF PROJECTACTIVITIES. THE CONTRACTOR MUST USE AND COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE UTILITYNOTIFICATION SYSTEM TO LOCATE ALL UNDERGROUND UTILITIES.F.PROTECT AND MAINTAIN IN OPERATION, ALL ACTIVE UTILITIES AND SYSTEMS THAT ARE NOT BEING REMOVED DURING ANYDEMOLITION ACTIVITIES.G.ARRANGE FOR AND COORDINATE WITH THE APPLICABLE UTILITY SERVICE PROVIDER(S) FOR THE TEMPORARY ORPERMANENT TERMINATION OF SERVICE REQUIRED BY THE PROJECT PLANS AND SPECIFICATIONS REGARDING THEMETHODS AND MEANS TO CONSTRUCT SAME. THESE ARE NOT THE PROFESSIONAL OF RECORD'S OR BOHLERRESPONSIBILITY. IN THE EVENT OF ABANDONMENT, THE CONTRACTOR MUST PROVIDE THE UTILITY ENGINEER AND OWNERWITH IMMEDIATE WRITTEN NOTIFICATION THAT THE EXISTING UTILITIES AND SERVICES HAVE BEEN TERMINATED ANDABANDONED IN ACCORDANCE WITH JURISDICTIONAL AND UTILITY COMPANY REQUIREMENTS.H.ARRANGE FOR AND COORDINATE WITH THE APPLICABLE UTILITY SERVICE PROVIDER(S) REGARDING WORKING "OFF-PEAK"HOURS OR ON WEEKENDS AS NECESSARY OR AS REQUIRED TO MINIMIZE THE IMPACT ON, OF, AND TO THE AFFECTEDPARTIES. WORK REQUIRED TO BE PERFORMED "OFF-PEAK" IS TO BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER.I.IN THE EVENT THE CONTRACTOR DISCOVERS ANY HAZARDOUS MATERIAL, THE REMOVAL OF WHICH IS NOT ADDRESSED INTHE PROJECT PLANS AND SPECIFICATIONS OR THE CONTRACT WITH THE OWNER/DEVELOPER, THE CONTRACTOR MUSTIMMEDIATELY CEASE ALL WORK IN THE AREA OF DISCOVERY, AND IMMEDIATELY NOTIFY, IN WRITING AND VERBALLY, THEOWNER, PROFESSIONAL OF RECORD AND BOHLER, THE DISCOVERY OF SUCH MATERIALS TO PURSUE PROPER ANDCOMPLIANT REMOVAL OF SAME.11.THE CONTRACTOR MUST NOT PERFORM ANY EARTH MOVEMENT ACTIVITIES, DEMOLITION OR REMOVAL OF FOUNDATION WALLS,FOOTINGS, OR OTHER MATERIALS WITHIN THE LIMITS OF DISTURBANCE, UNLESS SAME IS IN STRICT ACCORDANCE ANDCONFORMANCE WITH THE PROJECT PLANS AND SPECIFICATIONS, OR PURSUANT TO THE WRITTEN DIRECTION OF THE OWNER'SSTRUCTURAL OR GEOTECHNICAL ENGINEER.12.DEMOLITION ACTIVITIES AND EQUIPMENT MUST NOT USE OR INCLUDE AREAS OUTSIDE THE DEFINED PROJECT LIMIT LINE,WITHOUT SPECIFIC WRITTEN PERMISSION AND AUTHORITY OF AND FROM THE OWNER AND ALL GOVERNMENTAL AGENCIESWITH JURISDICTION.13.THE CONTRACTOR MUST BACKFILL ALL EXCAVATION RESULTING FROM, OR INCIDENTAL TO, DEMOLITION ACTIVITIES. BACKFILLMUST BE ACCOMPLISHED WITH APPROVED BACKFILL MATERIALS AND MUST BE SUFFICIENTLY COMPACTED TO SUPPORT ALLNEW IMPROVEMENTS AND MUST BE PERFORMED IN COMPLIANCE WITH THE RECOMMENDATIONS AND GUIDANCE ARTICULATEDIN THE GEOTECHNICAL REPORT. BACKFILLING MUST OCCUR IMMEDIATELY AFTER DEMOLITION ACTIVITIES AND MUST BEPERFORMED SO AS TO PREVENT WATER ENTERING THE EXCAVATION. FINISHED SURFACES MUST BE GRADED TO PROMOTEPOSITIVE DRAINAGE. THE CONTRACTOR IS RESPONSIBLE FOR COMPACTION TESTING AND MUST SUBMIT SUCH REPORTS ANDRESULTS TO THE PROFESSIONAL OF RECORD AND THE OWNER.14.EXPLOSIVES MUST NOT BE USED WITHOUT PRIOR WRITTEN CONSENT FROM BOTH THE OWNER AND ALL APPLICABLE,NECESSARY AND REQUIRED GOVERNMENTAL AUTHORITIES. PRIOR TO COMMENCING ANY EXPLOSIVE PROGRAM AND/OR ANYDEMOLITION ACTIVITIES, THE CONTRACTOR MUST ENSURE AND OVERSEE THE INSTALLATION OF ALL OF THE REQUIRED PERMITAND EXPLOSIVE CONTROL MEASURES THAT THE FEDERAL, STATE, AND LOCAL GOVERNMENTS REQUIRE. THE CONTRACTOR ISALSO RESPONSIBLE TO CONDUCT AND PERFORM ALL INSPECTION AND SEISMIC VIBRATION TESTING THAT IS REQUIRED TOMONITOR THE EFFECTS ON ALL LOCAL STRUCTURES AND THE LIKE.15.IN ACCORDANCE WITH FEDERAL, STATE, AND/OR LOCAL STANDARDS, THE CONTRACTOR MUST USE DUST CONTROL MEASURESTO LIMIT AIRBORNE DUST AND DIRT RISING AND SCATTERING IN THE AIR. AFTER THE DEMOLITION IS COMPLETE, THECONTRACTOR MUST CLEAN ALL ADJACENT STRUCTURES AND IMPROVEMENTS TO REMOVE ALL DUST AND DEBRIS WHICH THEDEMOLITION OPERATIONS CAUSE. THE CONTRACTOR IS RESPONSIBLE FOR RETURNING ALL ADJACENT AREAS TO THEIR"PRE-DEMOLITION" CONDITION AT CONTRACTOR'S SOLE COST.16.PAVEMENT MUST BE SAW CUT IN STRAIGHT LINES. ALL DEBRIS FROM REMOVAL OPERATIONS MUST BE REMOVED FROM THESITE AT THE TIME OF EXCAVATION. STOCKPILING OF DEBRIS OUTSIDE OF APPROVED AREAS WILL NOT BE PERMITTED,INCLUDING BUT NOT LIMITED TO, THE PUBLIC RIGHT-OF-WAY.17.THE CONTRACTOR MUST MAINTAIN A RECORD SET OF PLANS WHICH INDICATES THE LOCATION OF EXISTING UTILITIES THAT ARECAPPED, ABANDONED IN PLACE, OR RELOCATED DUE TO DEMOLITION ACTIVITIES. THIS RECORD DOCUMENT MUST BEPREPARED IN A NEAT AND WORKMAN-LIKE MANNER AND TURNED OVER TO THE OWNER/DEVELOPER UPON COMPLETION OF THEWORK, ALL OF WHICH IS AT THE CONTRACTOR'S SOLE COST.18.THE CONTRACTOR MUST EMPTY, CLEAN AND REMOVE FROM THE SITE ALL UNDERGROUND STORAGE TANKS, IF ENCOUNTERED,IN ACCORDANCE WITH FEDERAL, STATE, COUNTY AND LOCAL REQUIREMENTS, PRIOR TO CONTINUING CONSTRUCTION IN THEAREA AROUND THE TANK WHICH EMPTYING, CLEANING AND REMOVAL ARE AT THE CONTRACTOR'S SOLE COST.SITE LAYOUT NOTES(Rev. 1/2020)1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACTDOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLYCOMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITYWITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES.2.PRIOR TO THE COMMENCEMENT OF GENERAL CONSTRUCTION, THE CONTRACTOR MUST INSTALL SOIL EROSION CONTROL ANDANY STORMWATER POLLUTION PREVENTION PLAN (SWPPP) MEASURES NECESSARY, AS INDICATED ON THE APPROVED SOILEROSION AND SEDIMENT CONTROL PLAN AND IN ACCORDANCE WITH APPLICABLE AND/OR APPROPRIATE AGENCIES' GUIDELINESTO PREVENT SEDIMENT AND/OR LOOSE DEBRIS FROM WASHING ONTO ADJACENT PROPERTIES OR THE RIGHT OF WAY.3.ALL DIRECTIONAL/TRAFFIC SIGNING AND PAVEMENT STRIPING MUST CONFORM TO THE LATEST STANDARDS OF THE MANUAL ONUNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND ANY APPLICABLE STATE OR LOCALLY APPROVED SUPPLEMENTS,GUIDELINES, RULES, REGULATIONS, STANDARDS AND THE LIKE.4.THE LOCATIONS OF PROPOSED UTILITY POLES AND TRAFFIC SIGNS SHOWN ON THE PLANS ARE SCHEMATIC AND PRELIMINARY.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR FIELD-VERIFYING THEIR LOCATION. THE CONTRACTOR MUST COORDINATE THERELOCATION OF TRAFFIC SIGNS WITH THE ENTITY WITH JURISDICTION OVER THE PROJECT.5.ALL DIMENSIONS SHOWN ARE TO BOTTOM FACE OF CURB, EDGE OF PAVEMENT, OR EDGE OF BUILDING, EXCEPT WHENDIMENSION IS TO A PROPERTY LINE, STAKE OUT OF LOCATIONS OF INLETS, LIGHT POLES, ETC. MUST BE PERFORMED IN STRICTACCORDANCE WITH THE DETAILS, UNLESS NOTED CLEARLY OTHERWISE.GRADING NOTES(Rev. 1/2023)1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACTDOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLYCOMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITYWITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES.2.SITE GRADING MUST BE PERFORMED IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS AND THE RECOMMENDATIONSSET FORTH IN THE GEOTECHNICAL REPORT AS REFERENCED IN THIS PLAN SET. IF NO GEOTECHNICAL REPORT HAS BEENREFERENCED, THE CONTRACTOR MUST HAVE A GEOTECHNICAL ENGINEER PROVIDE WRITTEN SPECIFICATIONS ANDRECOMMENDATIONS PRIOR TO THE CONTRACTOR COMMENCING THE GRADING WORK. THE CONTRACTOR MUST FOLLOW THEREQUIREMENTS OF ALL MUNICIPAL, COUNTY, STATE, AND FEDERAL LAWS, WHICH HAVE JURISDICTION OVER THIS PROJECT.3.THE CONTRACTOR IS REQUIRED TO SECURE ALL NECESSARY AND/OR REQUIRED PERMITS AND APPROVALS FOR ALL OFF-SITEMATERIAL SOURCES AND DISPOSAL FACILITIES. THE CONTRACTOR MUST SUPPLY A COPY OF APPROVALS TO THEPROFESSIONAL OF RECORD, BOHLER AND THE OWNER PRIOR TO THE CONTRACTOR COMMENCING ANY WORK.4.THE CONTRACTOR IS FULLY RESPONSIBLE FOR VERIFYING EXISTING TOPOGRAPHIC INFORMATION AND UTILITY INVERTELEVATIONS PRIOR TO COMMENCING ANY CONSTRUCTION. SHOULD DISCREPANCIES BETWEEN THE PLANS AND INFORMATIONOBTAINED THROUGH FIELD VERIFICATIONS BE IDENTIFIED OR EXIST, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THEPROFESSIONAL OF RECORD AND BOHLER, IN WRITING.5.THE CONTRACTOR IS RESPONSIBLE FOR REMOVING AND REPLACING ALL UNSUITABLE MATERIALS WITH SUITABLE MATERIALSAS SPECIFIED IN THE GEOTECHNICAL REPORT. THE CONTRACTOR MUST COMPACT ALL EXCAVATED OR FILLED AREAS IN STRICTACCORDANCE WITH THE GEOTECHNICAL REPORT'S GUIDANCE. MOISTURE CONTENT AT TIME OF PLACEMENT MUST BESUBMITTED IN A COMPACTION REPORT PREPARED BY A QUALIFIED GEOTECHNICAL ENGINEER, REGISTERED WITH THE STATEWHERE THE WORK IS PERFORMED. THIS REPORT MUST VERIFY THAT ALL FILLED AREAS AND SUBGRADE AREAS WITHIN THEBUILDING PAD AREA AND AREAS TO BE PAVED HAVE BEEN COMPACTED IN ACCORDANCE WITH THESE PLANS, SPECIFICATIONSAND THE RECOMMENDATIONS SET FORTH IN THE GEOTECHNICAL REPORT AND ALL APPLICABLE REQUIREMENTS, RULES,STATUTES, LAWS, ORDINANCES AND CODES WHICH ARE IN EFFECT AND WHICH ARE APPLICABLE TO THE PROJECT. SUBBASEMATERIAL FOR SIDEWALKS, CURB, OR ASPHALT MUST BE FREE OF ORGANICS AND OTHER UNSUITABLE MATERIALS. SHOULDSUBBASE BE DEEMED UNSUITABLE BY OWNER/DEVELOPER, OR OWNER/DEVELOPER'S REPRESENTATIVE, SUBBASE MUST BEREMOVED AND FILLED WITH APPROVED FILL MATERIAL, COMPACTED AS THE GEOTECHNICAL REPORT DIRECTS. EARTHWORKACTIVITIES INCLUDING, BUT NOT LIMITED TO, EXCAVATION, BACKFILL, AND COMPACTING MUST COMPLY WITH THERECOMMENDATIONS IN THE GEOTECHNICAL REPORT AND ALL APPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS,ORDINANCES AND CODES. EARTHWORK ACTIVITIES MUST COMPLY WITH THE STANDARD STATE DOT SPECIFICATIONS FORROADWAY CONSTRUCTION (LATEST EDITION) AND ANY AMENDMENTS OR REVISIONS THERETO.6.IN THE EVENT OF A DISCREPANCY(IES) AND/OR A CONFLICT(S) BETWEEN PLANS, OR RELATIVE TO OTHER PLANS, THE GRADINGPLAN TAKES PRECEDENCE AND CONTROLS. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE PROFESSIONAL OF RECORDAND BOHLER, IN WRITING, OF ANY DISCREPANCY(IES) AND/OR CONFLICT(S).7.THE CONTRACTOR IS RESPONSIBLE TO IMPORT FILL OR EXPORT EXCESS MATERIAL AS NECESSARY TO CONFORM TO THEPROPOSED GRADING, AND TO BACKFILL EXCAVATIONS FOR THE INSTALLATION OF UNDERGROUND IMPROVEMENTS.ACCESSIBILITY DESIGN GUIDELINES(Rev. 1/2023)1.ALL ACCESSIBLE (A.K.A. ADA) COMPONENTS AND ACCESSIBLE ROUTES MUST BE CONSTRUCTED TO MEET, AT A MINIMUM, THEMORE STRINGENT OF: (A) THE REQUIREMENTS OF THE "AMERICANS WITH DISABILITIES ACT" (ADA) CODE (42 U.S.C. § 12101 ETSEQ. AND 42 U.S.C. § 4151 ET SEQ.); AND (B) ANY APPLICABLE LOCAL AND STATE GUIDELINES, AND ANY AND ALL AMENDMENTSTO BOTH, WHICH ARE IN EFFECT WHEN THESE PLANS WERE COMPLETED.2.THE CONTRACTOR MUST REVIEW ALL DOCUMENTS REFERENCED IN THESE NOTES FOR ACCURACY, COMPLIANCE ANDCONSISTENCY WITH INDUSTRY GUIDELINES.3.THE CONTRACTOR MUST EXERCISE APPROPRIATE CARE AND PRECISION IN CONSTRUCTION OF ACCESSIBLE (ADA)COMPONENTS AND ACCESSIBLE ROUTES FOR THE SITE. FINISHED SURFACES ALONG THE ACCESSIBLE ROUTE OF TRAVEL FROMPARKING SPACES, PUBLIC TRANSPORTATION, PEDESTRIAN ACCESS, AND INTER-BUILDING ACCESS, TO POINTS OF ACCESSIBLEBUILDING ENTRANCE/EXIT, MUST COMPLY WITH THE ACCESSIBLE GUIDELINES AND REQUIREMENTS WHICH INCLUDE, BUT ARENOT LIMITED TO THE FOLLOWING:A.ACCESSIBLE PARKING SPACES AND ACCESS AISLES SLOPES MUST NOT EXCEED 1:50 (2.0%) IN ANY DIRECTION.B.PATH OF TRAVEL ALONG ACCESSIBLE ROUTE MUST PROVIDE A 36-INCHES MINIMUM WIDTH (48-INCHES PREFERRED), OR ASSPECIFIED BY THE GOVERNING AGENCY. UNOBSTRUCTED WIDTH OF TRAVEL (CAR OVERHANGS AND/OR HANDRAILS) MUSTNOT REDUCE THIS MINIMUM WIDTH. THE SLOPE MUST NOT EXCEED 1:20 (5.0%) IN THE DIRECTION OF TRAVEL AND MUST NOTEXCEED 1:50 (2.0%) IN CROSS SLOPE. WHERE ACCESSIBLE PATH OF TRAVEL IS GREATER THAN 1:20 (5.0%), AN ACCESSIBLERAMP MUST BE PROVIDED. ALONG THE ACCESSIBLE PATH OF TRAVEL, OPENINGS MUST NOT EXCEED 1/2-INCH IN WIDTH.VERTICAL CHANGES OF UP TO 1/2-INCH ARE PERMITTED ONLY IF THEY INCLUDES A 1/4-INCH BEVEL AT A SLOPE NOTSTEEPER THAN 1:2. NO VERTICAL CHANGES OVER 1/4-INCH ARE PERMITTED.C.ACCESSIBLE RAMPS MUST NOT EXCEED A SLOPE OF 1:12 (8.3%) AND A RISE OF 30-INCHES. LEVEL LANDINGS MUST BEPROVIDED AT EACH END OF ACCESSIBLE RAMPS. LANDING MUST PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURES,AND MUST NOT EXCEED 1:50 (2.0%) SLOPE IN ANY DIRECTION. RAMPS THAT CHANGE DIRECTION BETWEEN RUNS ATLANDINGS MUST HAVE A CLEAR LANDING OF A MINIMUM OF 60-INCHES BY 60-INCHES. HAND RAILS ON BOTH SIDES OF THERAMP MUST BE PROVIDED ON AN ACCESSIBLE RAMP WITH A RISE GREATER THAN 6-INCHES.D.ACCESSIBLE CURB RAMPS MUST NOT EXCEED A SLOPE OF 1:12 (8.3%). WHERE FLARED SIDES ARE PROVIDED, THEY MUSTNOT EXCEED 1:10 (10%) SLOPE. LEVEL LANDING MUST BE PROVIDED AT RAMPS TOP AT A MINIMUM OF 36-INCHES LONG(48-INCHES PREFERRED). IN ALTERATIONS, WHEN THERE IS NO LANDING AT THE TOP, FLARE SIDES SLOPES MUST NOTEXCEED A SLOPE OF 1:12 (8.3%).E.DOORWAY LANDINGS AREAS MUST BE PROVIDED ON THE EXTERIOR SIDE OF ANY DOOR LEADING TO AN ACCESSIBLE PATHOF TRAVEL. THIS LANDING MUST BE SLOPED AWAY FROM THE DOOR NO MORE THAN 1:50 (2.0%) FOR POSITIVE DRAINAGE.THIS LANDING AREA MUST BE NO FEWER THAN 60-INCHES (5 FEET) LONG, EXCEPT WHERE OTHERWISE CLEARLY PERMITTEDBY ACCESSIBLE STANDARDS FOR ALTERNATIVE DOORWAY OPENING CONDITIONS. (SEE ICC/ANSI A117.1-2009 AND OTHERREFERENCES INCORPORATED BY CODE).F.WHEN THE PROPOSED CONSTRUCTION INVOLVES RECONSTRUCTION, MODIFICATION, REVISION OR EXTENSION OF OR TOACCESSIBLE COMPONENTS FROM EXISTING DOORWAYS OR SURFACES, THE CONTRACTOR MUST VERIFY ALL EXISTINGELEVATIONS SHOWN ON THE PLAN. NOTE THAT TABLE 405.2 OF THE DEPARTMENT OF JUSTICE'S ADA STANDARDS FORACCESSIBLE DESIGN ALLOWS FOR STEEPER RAMP SLOPES, IN RARE CIRCUMSTANCES. THE CONTRACTOR MUSTIMMEDIATELY NOTIFY THE PROFESSIONAL OF RECORD AND BOHLER, IN WRITING, OF ANY DISCREPANCIES AND/OR FIELDCONDITIONS THAT DIFFER IN ANY WAY OR IN ANY RESPECT FROM WHAT IS SHOWN ON THE PLANS BEFORE COMMENCINGANY WORK. CONSTRUCTED IMPROVEMENTS MUST FALL WITHIN THE MAXIMUM AND MINIMUM LIMITATIONS IMPOSED BY THEBARRIER FREE REGULATIONS AND THE ACCESSIBLE GUIDELINES.G.THE CONTRACTOR MUST VERIFY ALL OF THE SLOPES OF THE CONTRACTOR'S FORMS PRIOR TO POURING CONCRETE. IFANY NON-CONFORMANCE EXISTS OR IS OBSERVED OR DISCOVERED, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THEPROFESSIONAL OF RECORD AND BOHLER, IN WRITING, PRIOR TO POURING CONCRETE. THE CONTRACTOR IS SOLELYRESPONSIBLE FOR ALL COSTS TO REMOVE, REPAIR AND/OR REPLACE NON-CONFORMING CONCRETE AND/OR PAVEMENTSURFACES.4.IT IS STRONGLY RECOMMENDED THAT THE CONTRACTOR REVIEW THE INTENDED CONSTRUCTION TO ENSURE SAME ISCONSISTENT WITH THE LOCAL BUILDING CODE PRIOR TO COMMENCING CONSTRUCTION.DRAINAGE AND UTILITY NOTES(Rev. 3/2023)1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACTDOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLYCOMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITYWITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES.2.LOCATIONS OF ALL EXISTING AND PROPOSED SERVICES ARE APPROXIMATE, AND THE CONTRACTOR MUST INDEPENDENTLYVERIFY AND CONFIRM THOSE LOCATIONS AND SERVICES WITH LOCAL UTILITY COMPANIES PRIOR TO COMMENCING ANYCONSTRUCTION OR EXCAVATION. THE CONTRACTOR MUST INDEPENDENTLY VERIFY AND CONFIRM ALL SANITARY CONNECTIONPOINTS AND ALL OTHER UTILITY SERVICE CONNECTION POINTS IN THE FIELD, PRIOR TO COMMENCING ANY CONSTRUCTION. THECONTRACTOR MUST REPORT ALL DISCREPANCIES, ERRORS AND OMISSIONS IN WRITING, TO THE PROFESSIONAL OF RECORDAND BOHLER.3.THE CONTRACTOR MUST VERTICALLY AND HORIZONTALLY LOCATE ALL UTILITIES AND SERVICES INCLUDING, BUT NOT LIMITEDTO, GAS, WATER, ELECTRIC, SANITARY AND STORM, TELEPHONE, CABLE, FIBER OPTIC CABLE, ETC. WITHIN THE LIMITS OFDISTURBANCE OR WORK SPACE, WHICHEVER IS GREATER. THE CONTRACTOR MUST USE, REFER TO, AND COMPLY WITH THEREQUIREMENTS OF THE APPLICABLE UTILITY NOTIFICATION SYSTEM TO LOCATE ALL OF THE UNDERGROUND UTILITIES. THECONTRACTOR IS RESPONSIBLE FOR REPAIRING ALL DAMAGE TO ANY EXISTING UTILITIES WHICH OCCUR DURINGCONSTRUCTION, AT NO COST TO THE OWNER AND AT CONTRACTOR'S SOLE COST AND EXPENSE. THE CONTRACTOR MUST BEARALL COSTS ASSOCIATED WITH DAMAGE TO ANY EXISTING UTILITIES WHICH OCCURS DURING CONSTRUCTION. 4.THE CONTRACTOR MUST FIELD VERIFY THE PROPOSED INTERFACE POINTS (CROSSINGS) WITH EXISTING UNDERGROUNDUTILITIES BY USING A TEST PIT TO CONFIRM EXACT DEPTH, PRIOR TO COMMENCEMENT OF CONSTRUCTION.5.STORMWATER ROOF DRAIN LOCATIONS ARE BASED ON ARCHITECTURAL PLANS. THE CONTRACTOR IS RESPONSIBLE FORVERIFYING LOCATIONS, SIZE, AND MATERIAL OF SAME BASED UPON FINAL ARCHITECTURAL PLANS. 6.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING SITE PLAN DOCUMENTS AND ARCHITECTURAL PLANS FOR EXACTBUILDING UTILITY CONNECTION LOCATIONS; GREASE TRAP REQUIREMENTS; AND DETAILS, DOOR ACCESS, AND EXTERIORGRADING. THE ARCHITECT WILL DETERMINE THE UTILITY SERVICE SIZES. THE CONTRACTOR MUST COORDINATE INSTALLATIONOF UTILITY SERVICES WITH THE INDIVIDUAL COMPANIES TO AVOID CONFLICTS AND TO ENSURE THAT PROPER DEPTHS AREACHIEVED. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT INSTALLATION OF ALL IMPROVEMENTS COMPLIES WITH ALLUTILITY REQUIREMENTS OF THE APPLICABLE JURISDICTION AND REGULATORY AGENCIES AND ALL OTHER APPLICABLEREQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES AND, FURTHER, IS RESPONSIBLE FOR COORDINATING THEUTILITY TIE-INS/CONNECTIONS PRIOR TO CONNECTING TO THE EXISTING UTILITY/SERVICE. WHERE A CONFLICT(S) EXISTSBETWEEN THESE DOCUMENTS AND THE ARCHITECTURAL PLANS, OR WHERE ARCHITECTURAL PLAN UTILITY CONNECTIONPOINTS DIFFER, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE PROFESSIONAL OF RECORD AND BOHLER, IN WRITING, ANDPRIOR TO CONSTRUCTION, MUST RESOLVE SAME.7.ALL FILL, COMPACTION, AND BACKFILL MATERIALS REQUIRED FOR UTILITY INSTALLATION MUST BE EXACTLY AS PER THERECOMMENDATIONS PROVIDED IN THE GEOTECHNICAL REPORT AND THE CONTRACTOR MUST COORDINATE SAME WITH THEAPPLICABLE UTILITY COMPANY SPECIFICATIONS. WHEN THE PROJECT DOES NOT HAVE GEOTECHNICAL RECOMMENDATIONS,FILL AND COMPACTION MUST COMPLY WITH APPLICABLE REQUIREMENTS AND SPECIFICATIONS. THE PROFESSIONAL OFRECORD AND BOHLER ARE NOT RESPONSIBLE FOR DESIGN OF TRENCH BACKFILL OR FOR COMPACTION REQUIREMENTS8.DURING THE INSTALLATION OF SANITARY, STORM, AND ALL UTILITIES, THE CONTRACTOR MUST MAINTAIN A CONTEMPORANEOUSAND THOROUGH RECORD OF CONSTRUCTION TO IDENTIFY THE AS-INSTALLED LOCATIONS OF ALL UNDERGROUNDINFRASTRUCTURE. THE CONTRACTOR MUST CAREFULLY NOTE ANY INSTALLATIONS THAT DEVIATE, IN ANY RESPECT, FROM THEINFORMATION CONTAINED IN THESE PLANS. THIS RECORD MUST BE KEPT ON A CLEAN COPY OF THE APPROPRIATE PLAN(S),WHICH THE CONTRACTOR MUST PROMPTLY PROVIDE TO THE OWNER IMMEDIATELY UPON THE COMPLETION OF WORK.9.THE CONTRACTOR MUST ENSURE THAT ALL UTILITY TRENCHES LOCATED IN EXISTING PAVED ROADWAYS INCLUDING SANITARY,WATER AND STORM SYSTEMS, ARE REPAIRED IN ACCORDANCE WITH REFERENCED MUNICIPAL, COUNTY AND OR STATE DOTDETAILS AS APPLICABLE. THE CONTRACTOR MUST COORDINATE INSPECTION AND APPROVAL OF COMPLETED WORK WITH THEAGENCY WITH JURISDICTION OVER SAME.10.FINAL LOCATIONS OF PROPOSED UTILITY POLES, AND/ OR POLES TO BE RELOCATED ARE AT THE SOLE DISCRETION OF THERESPECTIVE UTILITY COMPANY, REGARDLESS OF WHAT THIS PLAN DEPICTS.11.WATER SERVICE MATERIALS, BURIAL DEPTH, AND COVER REQUIREMENTS MUST BE SPECIFIED BY THE LOCAL UTILITY COMPANY.THE CONTRACTOR MUST CONTACT THE APPLICABLE MUNICIPALITY TO CONFIRM THE PROPER WATER METER AND VAULT, PRIORTO COMMENCING CONSTRUCTION.12.THE TOPS OF EXISTING MANHOLES, INLET STRUCTURES, AND SANITARY CLEANOUT MUST BE ADJUSTED, AS NECESSARY, TOMATCH PROPOSED FINISHED GRADES WITH NO TRIPPING OR SAFETY HAZARD IN ACCORDANCE WITH ALL APPLICABLESTANDARDS, REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES.PROPOSED NOTECURB AND GUTTERSPILLTRANSITIONDEPRESSED CURB AND GUTTERTYPICAL NOTE TEXTNEIGHBORINGPROPERTY LINE /INTERIOR PARCEL LINESTANDARD DRAWING LEGENDFOR ENTIRE PLAN SETONSITE PROPERTYLINE / R.O.W. LINEEASEMENTLINESETBACKLINECONCRETE CURB &GUTTERUTILITY POLEWITH LIGHTPOLELIGHTTRAFFICLIGHTUTILITYPOLETYPICALLIGHTACORNLIGHTTYPICALSIGNPARKINGCOUNTSBORINGBENCHMARKEPSANITARYLABELSTORMLABELSANITARY SEWERLATERALUNDERGROUNDWATER LINEUNDERGROUNDELECTRIC LINEUNDERGROUNDGAS LINEOVERHEADWIREUNDERGROUNDTELEPHONE LINEUNDERGROUNDCABLE LINESTORMSEWERSANITARYSEWER MAINHYDRANTSANITARYMANHOLESTORMMANHOLEWATERMETERWATERVALVEGASVALVEGASMETERTYPICAL ENDSECTIONHEADWALL ORENDWALLGRATEINLETCURBINLETCLEANOUTELECTRICMANHOLETELEPHONEMANHOLEELECTRICBOXELECTRICPEDESTALMONITORINGWELLTESTPITCONTOURLINESPOTELEVATIONSLOWLOWLODLODLIMIT OF WORKLIMIT OF DISTURBANCEXA-100CEGOHTSLSDWMGGVC/OTEEB-#T-#SAWCUT LINETCBC516.00515.55FF 517.00ME|G516.00187190WSSAN-100GENERAL NOTES(Rev. 1/2023)1.THESE PLANS ARE SOLELY BASED ON INFORMATION THE OWNER AND OTHERS PROVIDED TO (HEREIN “BOHLER”) PRIOR TO THE DATE ON WHICH THE PROFESSIONAL OF RECORD AND BOHLER PREPARED THESE PLANS. THE CONTRACTOR MUSTFIELD VERIFY ALL EXISTING CONDITIONS AND IMMEDIATELY NOTIFY BOHLER , IN WRITING, IF ANY ACTUAL SITE CONDITIONS DIFFER FROM THOSESHOWN ON THESE PLANS, OR IF THE PROPOSED WORK CONFLICTS WITH ANY OTHER SITE FEATURES.2.THE CONTRACTOR MUST STRICTLY COMPLY WITH THESE NOTES AND ALL SPECIFICATIONS/REPORTS CONTAINED HEREIN. THE CONTRACTOR MUSTENSURE THAT ALL SUBCONTRACTORS FULLY AND COMPLETELY CONFORM TO AND COMPLY WITH THESE REQUIREMENTS, THESE NOTES, AND THEREQUIREMENTS ARTICULATED IN THE NOTES CONTAINED IN ALL THE OTHER DRAWINGS THAT COMPRISE THE PLAN SET OF DRAWINGS. ADDITIONALNOTES AND SPECIFIC PLAN NOTES MAY BE FOUND ON THE INDIVIDUAL PLANS. THESE GENERAL NOTES APPLY TO THIS ENTIRE DOCUMENT PACKAGE.IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL CONSTRUCTION CONTRACT DOCUMENTS INCLUDING, BUT NOT LIMITED TO, ALL OF THEDRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THE PROJECT WORK SCOPE, PRIOR TO THE INITIATION AND COMMENCEMENT OFCONSTRUCTION.3.PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR MUST CONFIRM WITH THE PROFESSIONAL OF RECORD AND BOHLER THATTHE LATEST EDITION OF THE DOCUMENTS AND/OR REPORTS REFERENCED WITHIN THE PLAN REFERENCES ARE BEING USED FOR CONSTRUCTION.THIS IS THE CONTRACTOR'S SOLE AND COMPLETE RESPONSIBILITY.4.PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR MUST ENSURE THAT ALL REQUIRED PERMITS AND APPROVALS HAVE BEENOBTAINED. NO CONSTRUCTION OR FABRICATION IS TO BEGIN UNTIL THE CONTRACTOR HAS RECEIVED AND THOROUGHLY REVIEWED THECONDITIONS OF APPROVAL TO ALL PLANS AND OTHER DOCUMENTS REVIEWED AND APPROVED BY THE PERMITTING AUTHORITIES AND HAS ALSOCONFIRMED THAT ALL NECESSARY AND REQUIRED PERMITS HAVE BEEN OBTAINED. THE CONTRACTOR MUST HAVE COPIES OF ALL PERMITS ANDAPPROVALS ON SITE AT ALL TIMES.5.THE CONTRACTOR MUST ENSURE THAT ALL WORK IS PERFORMED IN ACCORDANCE WITH THESE PLANS, SPECIFICATIONS/REPORTS ANDCONDITIONS OF APPROVAL, AND ALL APPLICABLE REQUIREMENTS, RULES, REGULATIONS, STATUTORY REQUIREMENTS, CODES, LAWS ANDSTANDARDS OF ALL GOVERNMENTAL ENTITIES WITH JURISDICTION OVER THIS PROJECT, AND ALL PROVISIONS IN AND CONDITIONS OF THECONSTRUCTION CONTRACT WITH THE OWNER/DEVELOPER INCLUDING ALL EXHIBITS, ATTACHMENTS AND ADDENDA TO SAME.6.PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR MUST COORDINATE THE BUILDING LAYOUT BY CAREFULLY REVIEWING THEMOST CURRENT ARCHITECTURAL, CIVIL AND STRUCTURAL CONSTRUCTION DOCUMENTS (INCLUDING, BUT NOT LIMITED TO, MECHANICAL,ELECTRICAL, PLUMBING AND FIRE SUPPRESSION PLANS, WHERE APPLICABLE). THE CONTRACTOR MUST IMMEDIATELY NOTIFY OWNER, ARCHITECTAND PROFESSIONAL OF RECORD AND BOHLER, IN WRITING, OF ANY CONFLICTS, DISCREPANCIES OR AMBIGUITIES WHICH EXIST BETWEEN THESEPLANS AND ANY OTHER PLANS THAT COMPRISE THE CONSTRUCTION DOCUMENTS.7.CONTRACTOR MUST REFER TO AND ENSURE COMPLIANCE WITH THE APPROVED ARCHITECTURAL/BUILDING PLANS OF RECORD FOR EXACTLOCATIONS AND DIMENSIONS OF ENTRY/EXIT POINTS, ELEVATIONS, PRECISE BUILDING DIMENSIONS, AND EXACT BUILDING UTILITY LOCATIONS.8.THE CONTRACTOR MUST FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS SHOWN ON THESE PLANS, PRIOR TO THE COMMENCEMENT OFCONSTRUCTION. THE CONTRACTOR MUST IMMEDIATELY NOTIFY PROFESSIONAL OF RECORD AND BOHLER, IN WRITING, IF ANY CONFLICTS,DISCREPANCIES, OR AMBIGUITIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION. NO EXTRA COMPENSATION WILL BE PAID TO THECONTRACTOR FOR WORK WHICH HAS TO BE RE-DONE OR REPAIRED DUE TO DIMENSIONS, MEASUREMENTS OR GRADES SHOWN INCORRECTLY ONTHESE PLANS PRIOR TO BOTH (A) THE CONTRACTOR GIVING PROFESSIONAL OF RECORD AND BOHLER WRITTEN NOTIFICATION OF SAME AND (B)PROFESSIONAL OF RECORD AND BOHLER, THEREAFTER, PROVIDING THE CONTRACTOR WITH WRITTEN AUTHORIZATION TO PROCEED WITH SUCHADDITIONAL WORK.9.THE CONTRACTOR MUST VERIFY ALL DIMENSIONS AND MEASUREMENTS INCLUDED ON DESIGN DOCUMENTS HEREIN AND MUST NOT SCALE OFF THEDRAWINGS DUE TO POTENTIAL PRINTING INACCURACIES. ALL DIMENSIONS AND MEASUREMENTS ARE TO BE CHECKED AND CONFIRMED BY THEGENERAL CONTRACTOR PRIOR TO PREPARATION OF SHOP DRAWINGS, FABRICATION/ORDERING OF PARTS AND MATERIALS AND COMMENCEMENTOF SITE WORK. SITE PLAN DRAWINGS ARE NOT INTENDED AS SURVEY DOCUMENTS. DIMENSIONS SUPERSEDE GRAPHICAL REPRESENTATIONS. THECONTRACTOR MUST MAKE CONTRACTOR'S OWN MEASUREMENTS FOR LAYOUT OF IMPROVEMENTS.10.THE OWNER AND CONTRACTOR MUST BE FAMILIAR WITH AND RESPONSIBLE FOR THE PROCUREMENT OF ANY AND ALL CERTIFICATIONS REQUIREDFOR THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 11.WHEN INCLUDED AS ONE OF THE REFERENCED DOCUMENTS, THE GEOTECHNICAL REPORT, SPECIFICATIONS AND RECOMMENDATIONS SET FORTHTHEREIN ARE A PART OF THE REQUIRED CONSTRUCTION DOCUMENTS AND, IN CASE OF CONFLICT, DISCREPANCY OR AMBIGUITY, THE MORESTRINGENT REQUIREMENTS AND/OR RECOMMENDATIONS CONTAINED IN: (A) THE PLANS; AND (B) THE GEOTECHNICAL REPORT ANDRECOMMENDATIONS, MUST TAKE PRECEDENCE UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PLANS. THE CONTRACTOR MUST NOTIFY THEPROFESSIONAL OF RECORD AND BOHLER, IN WRITING, OF ANY SUCH CONFLICT, DISCREPANCY OR AMBIGUITY BETWEEN THE GEOTECHNICALREPORT AND PLANS AND SPECIFICATIONS, PRIOR TO PROCEEDING WITH ANY FURTHER WORK. IF A GEOTECHNICAL REPORT WAS NOT CREATED,THEN THE CONTRACTOR MUST FOLLOW AND COMPLY WITH ALL OF THE REQUIREMENTS OF ANY AND ALL MUNICIPAL, COUNTY, STATE, AND FEDERALLAWS AND APPLICABLE SPECIFICATIONS WHICH HAVE JURISDICTION OVER THIS PROJECT.12.PROFESSIONAL OF RECORD AND BOHLER ARE NEITHER LIABLE NOR RESPONSIBLE FOR ANY SUBSURFACE CONDITIONS AND FURTHER, HAS NOLIABILITY FOR ANY HAZARDOUS MATERIALS, HAZARDOUS SUBSTANCES, OR POLLUTANTS ON, ABOUT OR UNDER THE PROPERTY. 13.THE CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING WHEN AND WHERE SHORING IS REQUIRED AND FOR INSTALLING ALL SHORING REQUIREDDURING EXCAVATION (TO BE PERFORMED IN ACCORDANCE WITH CURRENT OSHA STANDARDS) AND ANY ADDITIONAL PRECAUTIONS TO BE TAKEN TOASSURE THE STABILITY OF ADJACENT, NEARBY AND CONTIGUOUS STRUCTURES AND PROPERTIES. ALL OF THIS WORK IS TO BE PERFORMED ATCONTRACTOR'S SOLE COST AND EXPENSE.14.THE CONTRACTOR MUST EXERCISE EXTREME CAUTION WHEN PERFORMING ANY WORK ACTIVITIES ADJACENT TO PAVEMENT, STRUCTURES, ETC.WHICH ARE TO REMAIN EITHER FOR AN INITIAL PHASE OF THE PROJECT OR AS PART OF THE FINAL CONDITION. THE CONTRACTOR IS RESPONSIBLEFOR TAKING ALL APPROPRIATE MEASURES REQUIRED TO ENSURE THE STRUCTURAL STABILITY OF SIDEWALKS AND PAVEMENT, UTILITIES,BUILDINGS, AND INFRASTRUCTURE WHICH ARE TO REMAIN, AND TO PROVIDE A SAFE WORK AREA FOR THIRD PARTIES, PEDESTRIANS AND ANYONEINVOLVED WITH THE PROJECT. 15.DEBRIS MUST NOT BE BURIED ON THE SUBJECT SITE. ALL DEMOLITION AND CONSTRUCTION WASTES, UNSUITABLE EXCAVATED MATERIAL, EXCESSSOIL AND DEBRIS (SOLID WASTE) MUST BE DISPOSED OF IN ACCORDANCE WITH THE REQUIREMENTS OF ANY AND ALL MUNICIPAL, COUNTY, STATE,AND FEDERAL LAWS AND APPLICABLE CODES WHICH HAVE JURISDICTION OVER THIS PROJECT OR OVER THE CONTRACTOR. 16.IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO MAINTAIN RECORDS TO DEMONSTRATE PROPER AND FULLY COMPLIANT DISPOSAL ACTIVITIES,TO BE PROMPTLY PROVIDED TO THE OWNER UPON REQUEST. 17.THE CONTRACTOR MUST REPAIR, AT CONTRACTOR'S SOLE COST, ALL DAMAGE DONE TO ANY NEW OR EXISTING CONSTRUCTION OR PROPERTYDURING THE COURSE OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO DRAINAGE, UTILITIES, PAVEMENT, STRIPING, CURB, ETC. AND MUST BEARALL COSTS ASSOCIATED WITH SAME TO INCLUDE, BUT NOT BE LIMITED TO, REDESIGN, RE-SURVEY, RE-PERMITTING AND CONSTRUCTION. THECONTRACTOR IS RESPONSIBLE FOR AND MUST REPLACE ALL SIGNAL INTERCONNECTION CABLE, WIRING CONDUITS, AND ANY UNDERGROUNDACCESSORY EQUIPMENT DAMAGED DURING CONSTRUCTION AND MUST BEAR ALL COSTS ASSOCIATED WITH SAME. THE REPAIR OF ANY SUCH NEWOR EXISTING CONSTRUCTION OR PROPERTY MUST RESTORE SUCH CONSTRUCTION OR PROPERTY TO A CONDITION EQUIVALENT TO OR BETTERTHAN THE CONDITIONS PRIOR TO COMMENCEMENT OF THE CONSTRUCTION, AND IN CONFORMANCE WITH APPLICABLE CODES, LAWS, RULES,REGULATIONS, STATUTORY REQUIREMENTS AND STATUTES. THE CONTRACTOR MUST BEAR ALL COSTS ASSOCIATED WITH SAME. THE CONTRACTORMUST, PROMPTLY, DOCUMENT ALL EXISTING DAMAGE AND NOTIFY, IN WRITING, THE OWNER AND THE CONSTRUCTION MANAGER PRIOR TO THESTART OF CONSTRUCTION.18.THE PROFESSIONAL OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR AND HAVE NO CONTRACTUAL, LEGAL OR OTHER RESPONSIBILITIES FORJOB SITE SAFETY JOB SITE SUPERVISION, OR ANYTHING RELATED TO SAME. THE PROFESSIONAL OF RECORD AND BOHLER HAVE NOT BEENRETAINED TO PERFORM OR TO BE RESPONSIBLE FOR JOB SITE SAFETY, SAME BEING WHOLLY OUTSIDE OF PROFESSIONAL OF RECORD'S ANDBOHLER SERVICES AS RELATED TO THE PROJECT. THE PROFESSIONAL OF RECORD AND BOHLER ARE NOT RESPONSIBLE TO IDENTIFY OR REPORTANY JOB SITE SAFETY ISSUES OR ANY JOB SITE CONDITIONS, AT ANY TIME.19.THE CONTRACTOR MUST IMMEDIATELY IDENTIFY IN WRITING, TO THE PROFESSIONAL OF RECORD AND BOHLER , ANY DISCREPANCIES THAT MAY ORCOULD AFFECT THE PUBLIC SAFETY, HEALTH OR GENERAL WELFARE, OR PROJECT COST. IF THE CONTRACTOR PROCEEDS WITH CONSTRUCTIONWITHOUT PROVIDING PROPER WRITTEN NOTIFICATION AS DESCRIBED ABOVE, IT WILL BE AT THE CONTRACTOR'S OWN RISK AND, FURTHER, THECONTRACTOR MUST INDEMNIFY, DEFEND AND HOLD HARMLESS THE PROFESSIONAL OF RECORD AND BOHLER FOR ANY AND ALL DAMAGES, COSTS,INJURIES, ATTORNEY'S FEES AND THE LIKE WHICH RESULT FROM OR ARE IN ANY WAY RELATED TO SAME INCLUDING, BUT NOT LIMITED TO, ANYTHIRD PARTY AND FIRST PARTY CLAIMS. 20.THE PROFESSIONAL OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR ANY INJURY OR DAMAGES RESULTING FROM THE CONTRACTOR'SFAILURE TO BUILD OR CONSTRUCT IN STRICT ACCORDANCE WITH THE APPROVED PLANS, AND CURRENT CODES, RULES, STATUTES AND THE LIKE. IFTHE CONTRACTOR AND/OR OWNER FAIL TO BUILD OR CONSTRUCT IN STRICT ACCORDANCE WITH APPROVED PLANS, RULES, STATUTES, CODES ANDTHE LIKE, THE CONTRACTOR AND/OR OWNER AGREE TO AND MUST JOINTLY, INDEPENDENTLY, SEPARATELY, AND SEVERALLY INDEMNIFY AND HOLDTHE PROFESSIONAL OF RECORD AND BOHLER HARMLESS FOR AND FROM ALL INJURIES, CLAIMS AND DAMAGES THAT PROFESSIONAL OF RECORDAND BOHLER SUFFER AND ANY AND ALL COSTS THAT PROFESSIONAL OF RECORD AND BOHLER INCUR AS RELATED TO SAME.21.ALL CONTRACTORS MUST CARRY AT LEAST THE MINIMUM AMOUNT OF THE SPECIFIED AND COMMERCIALLY REASONABLE STATUTORY WORKER'SCOMPENSATION INSURANCE, EMPLOYER'S LIABILITY INSURANCE AND COMMERCIAL GENERAL LIABILITY INSURANCE (CGL) INCLUDING ALSO ALLUMBRELLA COVERAGES. ALL CONTRACTORS MUST HAVE THEIR CGL POLICIES ENDORSED TO NAME BOHLER , AND ITS PAST, PRESENT AND FUTUREOWNERS, OFFICERS, DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS, AGENTS, SERVANTS, EMPLOYEES,AFFILIATES, SUBSIDIARIES, AND RELATED ENTITIES, AND ITS SUBCONTRACTORS AND SUBCONSULTANTS AS ADDITIONAL NAMED INSUREDS AND TOPROVIDE CONTRACTUAL LIABILITY COVERAGE SUFFICIENT TO INSURE (DEFEND, IF APPLICABLE) AND HOLD HARMLESS AND INDEMNITY OBLIGATIONSASSUMED AND AGREED TO BY THE CONTRACTOR HEREIN. ALL CONTRACTORS MUST FURNISH BOHLER WITH CERTIFICATIONS OF INSURANCE ORCERTIFICATES OF INSURANCE AS EVIDENCE OF THE REQUIRED INSURANCE COVERAGES PRIOR TO COMMENCING ANY WORK AND UPON RENEWALOF EACH POLICY DURING THE ENTIRE PERIOD OF CONSTRUCTION AND FOR TWO YEARS AFTER THE COMPLETION OF CONSTRUCTION AND AFTERALL PERMITS ARE ISSUED, WHICHEVER DATE IS LATER. IN ADDITION, ALL CONTRACTORS AGREE THAT THEY WILL, TO THE FULLEST EXTENTPERMITTED UNDER THE LAW, INDEMNIFY, DEFEND AND HOLD HARMLESS BOHLER AND ITS PAST, PRESENT AND FUTURE OWNERS, OFFICERS,DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS, AGENTS, SERVANTS, EMPLOYEES, AFFILIATES, SUBSIDIARIES,AND RELATED ENTITIES, AND ITS SUBCONTRACTORS AND SUBCONSULTANTS FROM AND AGAINST ANY DAMAGES, INJURIES, CLAIMS, ACTIONS,PENALTIES, EXPENSES, PUNITIVE DAMAGES, TORT DAMAGES, STATUTORY CLAIMS, STATUTORY CAUSES OF ACTION, LOSSES, CAUSES OF ACTION,LIABILITIES OR COSTS, INCLUDING, BUT NOT LIMITED TO, REASONABLE ATTORNEYS' FEES AND DEFENSE COSTS, ARISING OUT OF OR IN ANY WAYCONNECTED WITH OR TO THE PROJECT, INCLUDING ALL CLAIMS BY EMPLOYEES OF THE CONTRACTOR(S), ALL CLAIMS BY THIRD PARTIES AND ALLCLAIMS RELATED TO THE PROJECT. THE CONTRACTOR MUST NOTIFY PROFESSIONAL OF RECORD, IN WRITING, AT LEAST THIRTY (30) DAYS PRIOR TOANY TERMINATION, SUSPENSION OR CHANGE OF ITS INSURANCE HEREUNDER.22.THE PROFESSIONAL OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR CONSTRUCTION METHODS, MEANS, TECHNIQUES OR PROCEDURES,GENERALLY OR FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES OR PROCEDURES FOR COMPLETION OF THE WORK DEPICTED BOTH ONTHESE PLANS, AND FOR ANY CONFLICTS IN SCOPE AND REVISIONS THAT RESULT FROM SAME. THE CONTRACTOR IS FULLY AND SOLELYRESPONSIBLE FOR DETERMINING THE MEANS AND METHODS FOR COMPLETION OF THE WORK, PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 23.NEITHER THE PROFESSIONAL ACTIVITIES OF BOHLER, NOR THE PRESENCE OF BOHLER AND/OR ITS PAST, PRESENT AND FUTURE OWNERS,OFFICERS, DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS, AGENTS, SERVANTS, EMPLOYEES, AFFILIATES,SUBSIDIARIES, AND RELATED ENTITIES, AND ITS SUBCONTRACTORS AND SUBCONSULTANTS AT A CONSTRUCTION/PROJECT SITE (HEREIN “BOHLERPARTIES”), RELIEVES OR WILL RELIEVE THE CONTRACTOR OF AND FROM CONSTRUCTION MEANS, METHODS, SEQUENCE, TECHNIQUES ORPROCEDURES NECESSARY FOR PERFORMING, OVERSEEING, SUPERINTENDING AND COORDINATING THE WORK IN ACCORDANCE WITH THECONTRACT DOCUMENTS AND COMPLIANCE WITH ALL HEALTH AND SAFETY PRECAUTIONS REQUIRED BY ANY REGULATORY AGENCIES WITHJURISDICTION OVER THE PROJECT AND/OR PROPERTY. BOHLER PARTIES HAVE NO AUTHORITY TO EXERCISE ANY CONTROL OVER (OR ANYRESPONSIBILITY FOR) ANY CONSTRUCTION, THE CONTRACTOR OR ITS EMPLOYEES RELATING TO THEIR WORK AND ANY AND ALL HEALTH ANDSAFETY PROGRAMS OR PROCEDURES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR JOB SITE SAFETY. THE CONTRACTOR MUST INDEMNIFY,DEFEND, PROTECT AND HOLD HARMLESS BOHLER PARTIES FOR AND FROM ANY LIABILITY TO BOHLER PARTIES RESULTING FROM THECONTRACTOR'S WORK, SERVICES AND/OR VIOLATIONS OF THIS NOTE, THESE NOTES OR ANY NOTES IN THE PLAN SET AND, FURTHER, THECONTRACTOR MUST NAME BOHLER AS AN ADDITIONAL INSURED UNDER THE GENERAL CONTRACTOR'S POLICIES OF GENERAL LIABILITY INSURANCEAS DESCRIBED ABOVE.24.WHEN IT IS CLEARLY AND SPECIFICALLY WITHIN BOHLER'S SCOPE OF SERVICES CONTRACT WITH THE OWNER/DEVELOPER, BOHLER WILL REVIEW ORTAKE OTHER APPROPRIATE ACTION ON THE CONTRACTOR SUBMITTALS, SUCH AS SHOP DRAWINGS, PRODUCT DATA, SAMPLES, AND OTHER DATA,WHICH THE CONTRACTOR IS REQUIRED TO SUBMIT, BUT ONLY FOR THE LIMITED PURPOSE OF EVALUATING CONFORMANCE WITH THE DESIGNINTENT AND THE INFORMATION SHOWN IN THE CONSTRUCTION CONTRACT DOCUMENTS. CONSTRUCTION MEANS AND METHODS AND/ORTECHNIQUES OR PROCEDURES, COORDINATION OF THE WORK WITH OTHER TRADES, AND CONSTRUCTION SAFETY PRECAUTIONS ARE THE SOLERESPONSIBILITY OF THE CONTRACTOR AND BOHLER HAS NO RESPONSIBILITY OR LIABILITY FOR SAME. BOHLER WILL PERFORM ITS SHOP DRAWINGREVIEW WITH REASONABLE PROMPTNESS, AS CONDITIONS PERMIT. ANY DOCUMENT, DOCUMENTING BOHLER'S REVIEW OF A SPECIFIC ITEM ORLIMITED SCOPE, MUST NOT INDICATE THAT BOHLER HAS REVIEWED THE ENTIRE ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. BOHLER IS NOTRESPONSIBLE FOR ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR MUST, IN WRITING, PROMPTLY AND IMMEDIATELYBRING ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS TO BOHLER'S ATTENTION. BOHLER IS NOT REQUIRED TO REVIEW PARTIALSUBMISSIONS OR THOSE FOR WHICH SUBMISSIONS OF CORRELATED ITEMS HAVE NOT BEEN RECEIVED. 25.IF THE CONTRACTOR DEVIATES FROM THESE PLANS AND/OR SPECIFICATIONS, INCLUDING THE NOTES CONTAINED HEREIN, WITHOUT FIRSTOBTAINING THE PRIOR WRITTEN AUTHORIZATION OF THE PROFESSIONAL OF RECORD AND BOHLER FOR ALL DEVIATIONS WITHIN PROFESSIONAL OFRECORD'S SCOPE, THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE PAYMENT OF ALL COSTS INCURRED IN CORRECTING ANY WORKPERFORMED WHICH DEVIATES FROM THE PLANS, ALL FINES AND/OR PENALTIES ASSESSED WITH RESPECT THERETO AND ALL COMPENSATORY ORPUNITIVE DAMAGES RESULTING THEREFROM AND, FURTHER, MUST DEFEND, INDEMNIFY, PROTECT, AND HOLD HARMLESS THE PROFESSIONAL OFRECORD AND BOHLER PARTIES TO THE FULLEST EXTENT PERMITTED UNDER THE LAW, FOR AND FROM ALL FEES, ATTORNEYS' FEES, DAMAGES,COSTS, JUDGMENTS, CLAIMS, INJURIES, PENALTIES AND THE LIKE RELATED TO SAME. 26.THE CONTRACTOR IS RESPONSIBLE FOR A MAINTAINING AND PROTECTING THE TRAFFIC CONTROL PLAN AND ELEMENTS IN ACCORDANCE WITHFEDERAL, STATE, AND LOCAL REQUIREMENTS, FOR ALL WORK THAT AFFECTS PUBLIC TRAVEL EITHER IN THE RIGHT OF WAY OR ON SITE. THE COSTFOR THIS ITEM MUST BE INCLUDED IN THE CONTRACTOR'S PRICE AND IS THE CONTRACTOR'S SOLE RESPONSIBILITY. 27.OWNER MUST MAINTAIN AND PRESERVE ALL PHYSICAL SITE FEATURES AND DESIGN FEATURES DEPICTED ON THE PLANS AND RELATED DOCUMENTSIN STRICT ACCORDANCE WITH THE APPROVED PLAN(S) AND DESIGN; AND, FURTHER, THE PROFESSIONAL OF RECORD AND BOHLER ARE NOTRESPONSIBLE FOR ANY FAILURE TO SO MAINTAIN OR PRESERVE SITE AND/OR DESIGN FEATURES. IF OWNER FAILS TO MAINTAIN AND/OR PRESERVEALL PHYSICAL SITE FEATURES AND/OR DESIGN FEATURES DEPICTED ON THE PLANS AND RELATED DOCUMENTS, OWNER AGREES TO INDEMNIFYAND HOLD THE PROFESSIONAL OF RECORD AND BOHLER PARTIES, HARMLESS FOR ALL INJURIES, DAMAGES AND COSTS THAT PROFESSIONAL OFRECORD AND BOHLER INCUR AS A RESULT OF SAID FAILURE OR FAILURE TO PRESERVE. 28.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ENSURING THAT ALL CONSTRUCTION ACTIVITIES AND MATERIALS COMPLY WITH AND CONFORM TOAPPLICABLE FEDERAL, STATE AND LOCAL RULES AND REGULATIONS, LAWS, ORDINANCES, AND CODES, AND ALL APPLICABLE REQUIREMENTS OFTHE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.) AS AMENDED, AND ANY MODIFICATIONS, AMENDMENTS OR REVISIONSTO SAME.29.THE CONTRACTOR MUST STRICTLY COMPLY WITH THE LATEST AND CURRENT OSHA STANDARDS AND REGULATIONS, AND/OR ANY OTHER AGENCYWITH JURISDICTION OVER EXCAVATION AND TRENCHING PROCEDURES. TRENCHING PRACTICES SHALL BE IN ACCORDANCE WITH 4VAC50-30-40SUBSECTION 16. PROFESSIONAL OF RECORD AND BOHLER HAS NO RESPONSIBILITY FOR OR AS RELATED TO EXCAVATION AND TRENCHINGPROCEDURES AND WORK. 30.THE CONTRACTOR AND THE OWNER MUST INSTALL ALL ELEMENTS AND COMPONENTS IN STRICT COMPLIANCE WITH AND IN ACCORDANCE WITHMANUFACTURER'S STANDARDS AND RECOMMENDED INSTALLATION CRITERIA AND SPECIFICATIONS. IF THE CONTRACTOR AND/OR OWNER FAIL TODO SO, THEY AGREE TO JOINTLY, INDEPENDENTLY, SEPARATELY, COLLECTIVELY, AND SEVERALLY INDEMNIFY, DEFEND, PROTECT AND HOLDPROFESSIONAL OF RECORD AND BOHLER PARTIES HARMLESS FOR ALL INJURIES AND DAMAGES THAT PROFESSIONAL OF RECORD SUFFERS ANDCOSTS THAT PROFESSIONAL OF RECORD INCURS AS A RESULT OF SAID FAILURE.31.THE CONTRACTOR IS RESPONSIBLE TO MAINTAIN AN ON-SITE STORMWATER POLLUTION PREVENTION PLAN (SWPPP) IN COMPLIANCE WITH THEENVIRONMENTAL PROTECTION AGENCY (EPA) REQUIREMENTS OR LOCAL GOVERNING AGENCY FOR SITES WHERE ONE (1) ACRE OR MORE ISDISTURBED BY CONSTRUCTION ACTIVITIES (UNLESS THE LOCAL JURISDICTION REQUIRES A DIFFERENT THRESHOLD). THE CONTRACTOR MUSTENSURE THAT ALL ACTIVITIES, INCLUDING THOSE OF ALL SUBCONTRACTORS, ARE IN COMPLIANCE WITH THE SWPPP, INCLUDING BUT NOT LIMITEDTO LOGGING ACTIVITIES (MINIMUM ONCE PER WEEK AND AFTER RAINFALL EVENTS) AND CORRECTIVE MEASURES, AS APPROPRIATE AND FURTHER,THE CONTRACTOR IS SOLELY AND COMPLETELY RESPONSIBLE FOR FAILING TO DO SO. 32.AS CONTAINED IN THESE DRAWINGS AND ASSOCIATED DOCUMENTS PREPARED BY THE PROFESSIONAL OF RECORD AND BOHLER, THE USE OF THEWORDS 'CERTIFY' OR 'CERTIFICATION' CONSTITUTE(S) AN EXPRESSION ONLY OF PROFESSIONAL OPINION REGARDING THE INFORMATION WHICH ISTHE SUBJECT OF THE PROFESSIONAL OF RECORD'S AND BOHLER KNOWLEDGE OR BELIEF AND IN ACCORDANCE WITH COMMON AND ACCEPTEDPROCEDURE CONSISTENT WITH THE APPLICABLE STANDARDS OF PRACTICE, AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE OF ANYNATURE OR TYPE, EITHER EXPRESSED OR IMPLIED, UNDER ANY CIRCUMSTANCES. BOHLER ENGINEERING VA, LLCOUTSIDE SOURCE NOTES(Rev. 11/2023)ANY INFORMATION, DRAWINGS, DATA, PLANS, SPECIFICATIONS, MATERIALS, FIGURES, DOCUMENTATION, REPORTS, AND THE LIKEWHICH IS INDICATED TO HAVE BEEN PREPARED “BY OTHERS” (HEREIN, “BY OTHERS REPORTS, DOCUMENTS AND DETAILS”) HAS BEENOR WILL BE CREATED, DEVELOPED, PREPARED, PERFORMED, AND ANALYZED BY AN ENTITY OR PARTY OTHER THAN THE “BOHLER”ENTITY INVOLVED WITH THIS PROJECT. THE “BOHLER” ENTITY IS NOT IN ANY WAY RESPONSIBLE FOR THE BY OTHERS REPORTS,DOCUMENTS AND DETAILS EVEN IF/WHERE INCLUDED IN THE “BOHLER” ENTITY'S PLANS, REPORTS, ETC. SAME HAS BEEN INCLUDEDON THIS PLAN FOR THE CONVENIENCE, ONLY, OF THE PROJECT OWNER, DEVELOPERS, CONTRACTORS AND CONSULTANTS AND INORDER TO COORDINATE THE “BOHLER” ENTITY'S DESIGN WITH THAT OF “OTHERS”. THE “BOHLER” ENTITY HAS ASSUMED, FORPURPOSES OF THIS PLAN, THAT THE BY OTHERS REPORTS, DOCUMENTS AND DETAILS ARE CURRENT AND, IF APPLICABLE,PREPARED IN STRICT ACCORDANCE WITH ALL APPLICABLE COUNTY, STATE, FEDERAL AND OTHER STATUTES, LAWS, RULES,REGULATIONS, ORDINANCES AND THE LIKE. THE “BOHLER” ENTITY SPECIFICALLY DISCLAIMS ANY AND ALL LIABILITY ANDRESPONSIBILITY FOR BY OTHERS REPORTS, DOCUMENTS AND DETAILS. THE ENTITY OR PERSON WHO CREATED THE INFORMATIONCONTAINED IN THE BY OTHERS REPORTS, DOCUMENTS AND DETAILS (EXCLUDING INFORMATION AND/OR DETAILS SOLELY SUPPLIEDBY A JURISDICTION AND/OR GOVERNING BODY) AGREES BY PARTICIPATING IN THIS PROJECT, RECEIVING, REVIEWING, USINGAND/OR RELYING UPON THIS DOCUMENT, AND/OR BY AGREEING TO THE PROJECT OWNER/DEVELOPER'S CONTRACT DOCUMENTS,TO DEFEND, INDEMNIFY, PROTECT AND HOLD HARMLESS THE “BOHLER” ENTITY THAT PREPARED THIS DOCUMENT AND ITSEMPLOYEES FOR ANY AND ALL DAMAGES, INJURIES, COSTS, EXPENSES AND THE LIKE, TO THE FULLEST EXTENT PERMITTED UNDERTHE LAW, WHICH THE “BOHLER” ENTITY AND/OR ITS EMPLOYEES SUFFER OR INCUR AS A RESULT OF INCLUDING ANY BY OTHERSREPORTS, DOCUMENTS AND DETAILS IN AND ON OR IN THIS PLAN. ANYONE OR ANY ENTITY WHO RECEIVED, RELIES UPON AND/ORUSES THIS PLAN, AGREES TO HOLD THE “BOHLER” ENTITY AND ITS EMPLOYEES HARMLESS FROM ANY CLAIMS, DAMAGES, INJURIES,COSTS AND EXPENSES, TO THE FULLEST EXTENT PERMITTED UNDER THE LAW, FOR ANY DAMAGES, INJURIES, COSTS, EXPENSESAND THE LIKE, TO THE FULLEST EXTENT PERMITTED UNDER THE LAW, WHICH IT OR THEY SUFFER OR INCUR AS A RESULT OF THEANY BY OTHERS REPORTS, DOCUMENTS AND DETAILS INCORPORATED IN THE PLAN, AND EXPRESSLY CONFIRMS THAT BYRECEIVING, RELYING UPON AND/OR USING SAME, THE “BOHLER” ENTITY SHALL HAVE NO LIABILITY RELATED TO SAME. WITHRESPECT TO ALL BY OTHERS REPORTS, DOCUMENTS AND DETAILS, CONTRACTOR MUST VERIFY ALL INFORMATION CONTAINED INTHE SCOPE OF ALL PARTIES INVOLVED IN PREPARING THE BY OTHERS REPORTS, DOCUMENTS AND DETAILS PRIOR TO COMMENCINGANY CONSTRUCTION AND MUST VERIFY THAT THE INFORMATION IS THE LATEST, THE MOST RECENT AND THE MOST CURRENTREPORT, DOCUMENT AND DETAIL. REFERENCES ON THIS PLAN TO INFORMATION PREPARED OR CONTAINED IN BY OTHERSREPORTS, DOCUMENTS AND DETAILS DEPICTING AN OFF-SITE AREA WHERE NO DETAIL IS INCLUDED IS A REFERENCE TO AN AREA,DETAIL, SPECIFICATION OR DESIGN THAT HAS NOT BEEN DESIGNED OR CONSTRUCTED BY THE “BOHLER” ENTITY AND REGARDINGWHICH THE “BOHLER” ENTITY HAS NO CONTROL OVER OR LIABILITY REGARDING, BUT IS ADDED TO THIS PLAN FOR INFORMATIONALPURPOSES, ONLY.C-102GENERALNOTESANDLEGEND May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA220135.00-0A----->LAYOUT: C-102 NOTEYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-CNDSPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026STANDARDABBREVIATIONSFOR ENTIRE PLAN SETAASHTOAMERICAN ASSOCIATION OFSTATE HIGHWAY ANDTRANSPORTATION OFFICIALSACACRE / ACRESADAREA DRAINADAACCESSIBLE / AMERICANSWITH DISABILITIES ACTAGABOVE GROUNDAPPROXAPPROXIMATEARCHARCHITECTURALASPHASPHALTASSFAREA SUBJECT TOSTORMWATER FLOWAGEASSOCASSOCIATIONBCBOTTOM OF CURBBFBASEMENT FLOORBIOBIOGARDENBITBITUMINOUSBKBLOCKBLBASELINEBLDGBUILDINGBMBENCH MARKBRLBUILDING RESTRICTION LINEBVWBORDERING VEGETATIVEWETLANDCBCATCH BASINCFCUBIC FEETCICURB INLETCITCHANGE IN TYPECLCENTER LINECMPCORRUGATED METAL PIPEC/OCLEAN OUTCONCCONCRETECONNCONNECTIONCOORDCOORDINATECPPCORRUGATED PLASTIC PIPECYCUBIC YARDDECDECORATIVEDEPDEPARTMENT OFENVIRONMENTAL PROTECTIONDETDETENTIONDIADIAMETERDMHDRAINAGE MANHOLEDOMDOMESTICDOTDEPARTMENT OFTRANSPORTATIONDPDESIGN POINTDWLDASHED WHITE LINEDYLDOUBLE YELLOW LINEEGEXISTING GRADEELECELECTRICELEVELEVATIONEORENGINEER OF RECORDEP / EOPEDGE OF PAVEMENTES / EOSEDGE OF SHOULDEREWEND WALLEXEXISTINGFDCFIRE DEPARTMENTCONNECTIONFEMAFEDERAL EMERGENCYMANAGEMENT AGENCYFESFLARED END SECTIONFFFINISH / FIRST FLOORFFEFINISH / FIRST FLOORELEVATIONFGFINISH GRADEFHFIRE HYDRANTFMFORCE MAINFOFIBER OPTICGGRADEGCGENERAL CONTRACTORGEOGEOTECH/GEOTECHNICALGF / GFEGARAGE FLOOR ELEVATION(AT DOOR)GFAGROSS FLOOR AREAGHGRADE HIGH (WALL)GLGRADE LOW (WALL)GRTGRATEGTGREASE TRAPGVGATE VALVEHDPEHIGH DENSITY POLYETHYLENEHORHORIZONTALHPHIGH POINTHWHEADWALLICSINLET CONTROL STRUCTUREINFINFILTRATIONINTINTERSECTIONINVINVERTLFLINEAR FOOTLOCLIMIT OF CLEARINGLODLIMIT OF DISTURBANCELOSLINE OF SIGHTLOWLIMIT OF WORKLPLOW POINTLSLANDSCAPELSALANDSCAPE AREAMAXMAXIMUMMEMATCH EXISTINGMEPMECHANICAL, ELECTRICAL,AND PLUMBINGMHMANHOLEMINMINIMUMMJMECHANICAL JOINTMUTCDMANUAL ON UNIFORM TRAFFICCONTROL DEVICESNOAANATIONAL OCEANIC ANDATMOSPHERICADMINISTRATIONNRCSNATIONAL RESOURCECONSERVATION SERVICEO&MOPERATIONS ANDMAINTENANCEOCON CENTEROCSOUTLET CONTROLSTRUCTUREOGSOIL AND GRIT SEPARATORORDORDINANCEPA / POAPOINT OF ANALYSISPCPOINT OF CURVATUREPCCRPOINT OF CURVATURE, CURBRETURNPERFPERFORATEDPGPROPOSED GRADEPIPOINT OF INTERSECTIONPOGPOINT OF GRADEPPPOLYPROPYLENE PIPEPROPPROPOSEDPTPOINT OF TANGENCYPTCRPOINT OF TANGENCY, CURBRETURNPVIPOINT OF VERTICALINTERSECTIONPVMTPAVEMENTPVTPOINT OF VERTICALTANGENCYRRADIUS / RADIIR/WRIGHT-OF-WAY /RIGHTS-OF-WAYRCPREINFORCED CONCRETE PIPERDROOF DRAINREGSREGULATIONSRELOTO BE RELOCATEDREQREQUIREDRETRETENTIONRETWALLRETAINING WALLRETOTO BE RETURNED TO OWNERRGRAIN GARDENSSLOPESANSANITARY SEWERSESCSOIL EROSION AND SEDIMENTCONTROLSFSQUARE FEETSHLOSTATE HIGHWAY LAYOUTSMHSANITARY MANHOLESTASTATIONSTMSTORM WATER / STORMSEWERSWLSINGLE/SOLID WHITE LINESWPPPSTORMWATER POLLUTIONPREVENTION PLANTBATO BE ABANDONEDTBRTO BE REMOVEDTBVTO BE VACATEDTCTOP OF CURBTcTIME OF CONCENTRATIONTDTRENCH DRAINTELETELECOMMUNICATIONS /TELEDATATPFTREE PROTECTION FENCETRTO REMAINTRANSTRANSITIONTYPTYPICALUGUNDERGROUNDUPUTILITY POLEUSGSUNITED STATES GEOLOGICALSURVEYVERTVERTICALVIFVERIFY IN FIELDWWIDE / WIDTHW/LWATER LINEWMWATER METERWQUWATER QUALITY UNITYDYARD DRAIN#NUMBER#:#SLOPE EXPRESSED INHORIZONTAL:VERTICAL INFEET±PLUS OR MINUS°DEGREEØDIAMETER'FEET/FOOT"INCHESSOIL EROSION & SEDIMENT CONTROL PLAN NOTES(Rev. 12/2024)1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACTDOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN AND CONTRACTOR MUST REFER TO THEM. THE CONTRACTORMUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS’ SPECIFICNOTES.2.INSTALLATION OF EROSION CONTROL DEVICES MUST BE IN ACCORDANCE WITH ALL OF THE MANUFACTURER'SRECOMMENDATIONS.3.CONTRACTOR MUST INSTALL ADDITIONAL EROSION CONTROL MEASURES IF ENGINEER OR JURISDICTIONAL AGENCY SOREQUIRES, TO PREVENT THE DISCHARGE OF SEDIMENT LADEN RUNOFF FROM EXITING THE SITE.4.THE CONTRACTOR IS RESPONSIBLE FOR INSPECTING AND MAINTAINING ALL EROSION CONTROL MEASURES ON THE SITE UNTILPERMANENT STABILIZATION IS ESTABLISHED UNLESS INDICATED OTHERWISE IN LOCAL, STATE AND/OR FEDERAL PROJECTAPPROVALS. THE COST OF INSTALLING AND MAINTAINING THE EROSION CONTROL MEASURES MUST BE INCLUDED IN THE BIDPRICE FOR THE SITE WORK AND THE CONTRACTOR IS RESPONSIBLE FOR ALL SUCH COSTS. LODLOWLOWCC CC CC CC CC CC CC CC CC CC CC CC CCCCCCCCCCCCCCPROP 5' SIDEWALKPROP 5' SIDEWALK PROP 5' S I D E W A L K PRO P 5 ' S I D E W A L KCOSTELLO DRIVEFR O N T R O Y A L P I K E - U . S . R O U T E 5 2 23C9B41D41CW1B41D3C3B41D3C14C14B32B32C9B3C41C283B3BC-103GENERALNOTESANDLEGEND May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA220135.00-0A----->LAYOUT: C-103 NOTEYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-CNDSPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026REVISED: 01/10/2023 VDOT GENERAL NOTES1.THESE PLANS WERE PREPARED IN ACCORDANCE WITH THE REQUIREMENTS OF (SELECT ONE):VDOT SECONDARY STREET ACCEPTANCE REQUIREMENTS (SSAR 24VAC-30-92 EFFECTIVE FEBRUARY 1, 2012 AND VDOT ROAD DESIGN MANUAL APPENDIX B1). VDOT SECONDARY STREET ACCEPTANCE REQUIREMENTS (SSAR 24VAC-30-92 EFFECTIVE FEBRUARY 1, 2012 AND VDOT ROAD DESIGN MANUAL APPENDIX B2 ASAPPROVED FOR USE IN DESIGNATED HIGH DENSITY DEVELOPMENT AREAS). VDOT ROAD DESIGN MANUAL APPENDIX C, RURAL AND URBAN GEOMETRIC DESIGN STANDARDS EFFECTIVE AT THE TIME OF VDOT RECOMMENDED PLANAPPROVAL;LIST STANDARD USED: GS-______.2.VDOT APPROVED EXCEPTIONS/WAIVERS (MUST BE INCORPORATED IN THE PLAN):·ACCESS MANAGEMENT - DATE OF APPROVAL: ______________·SSAR- DATE OF APPROVAL: ______________·DESIGN WAIVER - DATE OF APPROVAL: ______________·OTHER______________ DATE OF APPROVAL: ______________3.SSAR CONNECTIVITY SUMMARY (PROVIDE A CHECK MARK ✓ WHERE APPLICABLE OR WRITE N/A):·CONNECTIONS IN MULTIPLE DIRECTIONS (FIRST CONNECTION MUST BE TO A VDOT MAINTAINED ROAD, THE SECOND CONNECTION MAY EITHER BE TO A VDOTROAD OR TO A STUB OUT)·STUB OUT CONNECTION (THE PROP. RIGHT OF WAY TERMINATES AT PARCEL ABUTTING THE DEVELOPMENT AND CONSISTS OF A SHORT SEGMENT THAT ISINTENDED TO SERVE CURRENT AND FUTURE DEVELOPMENT; THE APPLICANT MUST VERIFY THAT CONNECTION WITH A FUTURE STREET IS FEASIBLE)·NETWORK ADDITIONS PROVIDING DIRECT ACCESS TO (I) MORE THAN 200 DWELLING UNITS OR (II) LOTS WHOSE TRIP GENERATION IS EXPECTED TO BE OVER 2,000VPD MAY BE ACCEPTED INTO THE SECONDARY SYSTEM OF STATE HIGHWAYS IF THE NETWORK ADDITION PROVIDES AN ADDITIONAL EXTERNAL CONNECTIONBEYOND THAT REFERENCED ABOVE.4.ALL WORK ON THIS PROJECT SHALL CONFORM TO THE CURRENT EDITIONS OF AND LATEST REVISIONS TO THE VIRGINIA DEPARTMENT OF TRANSPORTATION(VDOT) ROAD AND BRIDGE SPECIFICATIONS AND STANDARDS, THE VIRGINIA EROSION AND SEDIMENT CONTROL REGULATIONS, AND ANY OTHER APPLICABLESTATE, FEDERAL OR LOCAL REGULATIONS. IN CASE OF A DISCREPANCY OR CONFLICT BETWEEN THE STANDARDS OR SPECIFICATIONS AND REGULATIONS, THEMOST STRINGENT SHALL GOVERN.5.ALL RIGHT OF WAY DEDICATED TO PUBLIC USE SHALL BE CLEAR AND UNENCUMBERED.6.ALL UTILITIES, INCLUDING ALL POLES, ARE TO BE RELOCATED AT THE DEVELOPER'S EXPENSE, PRIOR TO CONSTRUCTION.7.THE DEVELOPER IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING ROADS AND UTILITIES WHICH OCCUR AS A RESULT OF PROJECT CONSTRUCTION WITHIN ORCONTIGUOUS TO EXISTING RIGHT OF WAY.8.OPEN CUTTING OF PAVED OR SURFACE TREATED ROADS IS NOT PERMITTED. ALL UTILITIES WHICH WILL BE PLACED UNDER EXISTING STREETS ARE TO BE BOREDOR JACKED. ANY EXCEPTIONS, DUE TO EXTENUATING CIRCUMSTANCES, ARE TO BE ADDRESSED AT THE PERMIT STAGE.9.THE PAVEMENT DESIGN IS BASED ON AN ASSUMED CBR VALUE OF 10 (USE A CBR VALUE OF 6 IN LOUDOUN CO.). SOIL TESTS OF SUBGRADE MUST BE SUBMITTEDFOR THE ACTUAL DETERMINATION OF THE REQUIRED THICKNESS OF THE PAVEMENT INCLUDING LAYERS OF ASPHALT AND SUBBASE PRIOR TO SUBBASEPLACEMENT.10.PAVEMENT DESIGN SHALL BE PROVIDED IN ACCORDANCE WITH THE PAVEMENT DESIGN GUIDE FOR SUBDIVISION AND SECONDARY ROADS IN VIRGINIA. FORPRIMARY ROADS AND INTERSTATE HIGHWAYS WHERE TRUCK TRAFFIC EXCEEDS 5%, PAVEMENT DESIGN SHALL BE PROVIDED IN ACCORDANCE WITH AASHTOGUIDELINES. TYPICAL PAVEMENT SECTIONS SHALL DEPICT THE TOP 6” OF THE SUBGRADE IMMEDIATELY UNDER THE PAVEMENT STRUCTURE COMPACTED TO 100%OF THE THEORETICAL MAXIMUM DRY DENSITY.11.ALL UNTREATED AGGREGATE USED IN BASE OR SUBBASE COURSES SHALL BE 21B, EXCEPT ON ROADS WITH AN ADT OF 1000 VPD OR LESS, WHERE 21AAGGREGATE MAY BE USED. WHEN 21B AGGREGATE IS USED, UD-4 UNDERDRAINS MUST BE PROVIDED.12.A 4” (MIN.) LAYER OF STONE IS REQUIRED BENEATH CURB AND GUTTER (MAY BE SHOWN ON TYPICAL SECTION IN LIEU OF A NOTE).13.THE ENTIRE SURFACE OF THE ROADWAY (OLD AND NEW PORTIONS) SHALL BE OVERLAID AND RE-STRIPED AS REQUIRED BY VDOT PERSONNEL. OVERLAY OFEXISTING PAVEMENT SHALL BE A MINIMUM OF 1.25” DEPTH; ANY COSTS ASSOCIATED WITH PAVEMENT OVERLAY, OR THE MILLING OF EXISTING PAVEMENT TOOBTAIN REQUIRED DEPTH, SHALL BE ASSUMED BY THE DEVELOPER.14.A SMOOTH GRADE SHALL BE MAINTAINED FROM THE CENTERLINE OF THE EXISTING ROAD TO THE PROPOSED EDGE OF PAVEMENT TO PRECLUDE THE FORMINGOF FALSE GUTTERS AND/OR THE PONDING OF ANY WATER IN THE ROADWAY.15.ASPHALT PAVEMENT WIDENING SHALL CONFORM TO VDOT STANDARD WP-2.16.ANY TYPE OF REVERSE CURB (SPILL CURB, CG-6R, ETC.) AND TRANSITION TO THESE CURBS SHALL NOT BE USED WITHIN THE PUBLIC RIGHT OF WAY.17.THE COUNTY/TOWN SHALL OBTAIN A PERMIT FOR ALL SIDEWALKS/CROSSWALKS WITHIN THE RIGHT OF WAY THAT DO NOT QUALIFY FOR VDOT MAINTENANCE.18.ADDITIONAL DITCH LININGS OR SILTATION AND EROSION CONTROL MEASURES SHALL BE PROVIDED, AT THE DEVELOPER'S EXPENSE, AS DETERMINED NECESSARYBY VDOT AND/OR THE COUNTY/TOWN DURING FIELD REVIEW. ALL COSTS SHALL BE ASSUMED BY THE DEVELOPER.19.STANDARD GUARDRAILS AND/OR HANDRAILS SHALL BE INSTALLED AT HAZARDOUS LOCATIONS AS DESIGNATED DURING FIELD REVIEW BY THE COUNTY/TOWNINSPECTOR OR VDOT.20.A LANDSCAPING AND IRRIGATION SYSTEMS PLAN SHALL BE SUBMITTED FOR VDOT APPROVAL PRIOR TO INSTALLING ANY LANDSCAPING AND IRRIGATION SYSTEMSWITHIN THE PUBLIC RIGHT OF WAY.21.FLOWERS, SHRUBS, TREES, AND IRRIGATION SHALL NOT BE PLACED WITHIN STATE MAINTAINED RIGHT OF WAY LIMITS WITHOUT AN APPROVED SET OF PLANS ANDAN APPROVED PLANTING AGREEMENT. NO IRRIGATION (SPRINKLER) SYSTEMS, BRICK COLUMNS, END WALLS, AND/OR BRICK MAILBOXES WILL BE CONSTRUCTEDOR INSTALLED WITHIN STATE MAINTAINED RIGHT OF WAY LIMITS WITHOUT A PERMIT. ANY OF THE ABOVE ITEMS FOUND IN THE RIGHT OF WAY WITHOUT A PERMITWILL BE REMOVED, AND ALL COSTS OF THE REMOVAL WILL BE BORNE BY THE OWNER AND/OR DEVELOPER.22.TRAFFIC CONTROL DEVICES OR ADVISORY SIGNS, SUCH AS MULTIWAY STOPS, SPEED LIMITS, WATCH FOR CHILDREN, PEDESTRIAN TRAFFIC ETC., SHALL NOT BEINSTALLED UNLESS SPECIFICALLY APPROVED BY VDOT TRAFFIC ENGINEERING SECTION. SHOULD UNAPPROVED SIGNS BE NOTED AT THE TIME OF VDOTINSPECTION, THE ROAD ACCEPTANCE PROCESS SHALL BE TERMINATED IMMEDIATELY AND NOT RECOMMENCED UNTIL A DETERMINATION IS MADE REGARDINGTHE APPROVAL OF ANY ADDITIONAL SIGNS. IMMEDIATE REMOVAL OF SUCH SIGNS SHALL NOT NEGATE THE NEED FOR THE SUBMISSION OF A REVISION.23.A SPEED STUDY CERTIFIED BY A PROFESSIONAL ENGINEER SHALL BE SUBMITTED FOR VDOT APPROVAL PRIOR TO THE STREET ACCEPTANCE FOR ANY ROAD TOBE POSTED OTHER THAN THE STATUTORY SPEED LIMIT.24.THE DEVELOPER IS RESPONSIBLE FOR ALL TRAFFIC CONTROL. THE DEVELOPER SHALL SUBMIT A SIGNING, STRIPING AND/OR SIGNALIZATION PLAN TO THE VDOTLAND DEVELOPMENT SECTION PRIOR TO PERMIT APPLICATION. THE DEVELOPER SHALL NOT COMMENCE CONSTRUCTION OF ANY PAVEMENT COURSE WITHOUTAN APPROVED STRIPING PLAN.25.THE DEVELOPER IS RESPONSIBLE FOR THE DESIGN AND CONSTRUCTION OF ANY TRAFFIC SIGNAL INSTALLATION OR MODIFICATION WHICH WILL BE NECESSARYAS A RESULT OF THE DEVELOPMENT OF THIS SITE.26.DURING CONSTRUCTION, THE MAINTENANCE OF TRAFFIC SHALL CONFORM TO THE REQUIREMENTS IN THE MOST RECENT VERSION OF THE VIRGINIA WORK AREAPROTECTION MANUAL AND THE MUTCD.27.THE ENGINEER OF RECORD, WHOSE PROFESSIONAL SEAL IS AFFIXED TO THIS PLAN, IS RESPONSIBLE TO ENSURE ALL VDOT STANDARDS ARE MET. VDOT REVIEWAND SIGNATURE OF THIS PLAN SHALL NOT BE INTERPRETED AS A GUARANTEE THE PLAN IS WITHOUT ERROR. THAT IS SOLELY THE RESPONSIBILITY OF THEENGINEER OF RECORD.28.ANY FIXTURES OR FEATURES BEING PLACED WITHIN THE VDOT RIGHT OF WAY THAT DO NOT SERVE THE GENERAL PUBLIC WILL REQUIRE A SEPARATE LAND USEPERMIT (LUP-A) AND COVENANT OF PERPETUAL MAINTENANCE (CPM).N/AN/AN/AN/AN/AN/ASOILS MAPSCALE: 1" = 500'1"=500'0500125250500XxXLEGENDSoil IDNumbersSoil Series NameSoil DrainageClassHydrologic SoilGroupHydric SoilRating1BBerks channery siltloam, 3 to 8 percentslopesWell DrainedBNo3BBlairton silt loam, 2to 7 percent slopesModerately WellDrainedC/DNo3CBlairton silt loam, 7to 15 percent slopesModerately WellDrainedC/DNo9BClearbrook channerysilt loam, 2 to 7percent slopesSomewhatPoorly DrainedC/DNo14BFrederick-Poplimentoloams, 2 to 7 percentslopesWell DrainedBNo14CFrederick-Poplimentoloams, 7 to 15percent slopesWell DrainedBNo32BOaklet silt loam, 2 to7 percent slopesWell DrainedCNo32COaklet silt loam, 7 to15 percent slopesWell DrainedCNo41CWeikert-Berkschannery silt loams, 8to 15 percent slopesWell DrainedDNo41DWeikert-Berkschannery silt loams,15 to 25 percentslopesWell DrainedDNo28Lobdell silt loamModerately WellDrainedCNoWWaterN/AN/AN/ASOIL BOUNDARIESSOIL LABELSSITE DATAADDRESS251 FRONT ROYAL PIKEJURISDICTIONFREDERICK COUNTY, VAZONINGB-2 GENERAL BUSINESS DISTRICTPROPOSED USERETAIL BUILDING AND FUEL CANOPYSITE AREA17.29 ACRESLIMITS OF DISTURBANCE12.73 ACRESPARKING REQUIREMENTSREQUIREDPROPOSED WAREHOUSE/INDOOR STORAGE(1.5 PER EMPLOYEE + 1 FOR EACHCOMPANY VEHICLE)1.5 X (NUMBER OF ANTICIPATEDEMPLOYEES) = 1.5 X 300EMPLOYEES = 450 SPACES744 PARKING SPACES ADA(2% OF TOTAL PARKING SPACES)(0.02)X(744 PARKING SPACES) = 1530 SPACES(INCLUDING 7 VAN SPACES)LOADING REQUIREMENTSREQUIREDPROPOSED(1 FOR EACH 40,000 SF OF FLOORAREA)139,698 SF / (40,000 SF / LOADINGSPACE) = 4 LOADING SPACES4 LOADING SPACESBUILDING REQUIREMENTSREQUIREDPROPOSEDFRONT (WEST)50'232.7'FRONT (SOUTH)35'98.9'SIDE (NORTH)N/A84.3'REAR (EAST)N/A59.3'BUILDING AREAN/A160,407 SFMAX. FLOOR AREA RATIO (FAR)1.0160,407/753,153 = 0.21MAX. BUILDING HEIGHT35'30.5' C-201 C-202 C-203 LOT 2GARBER ESTATE SUBDIVISIOND.B. 838 PG. 1360LANDS OFCOSTCO WHOLESALE CORPORATIONINSTR. #190006190TM: 64-8-2AREA: 4.293 AC. (R&M)OR 187,007 S.F. (M)"NO BUILDINGS"ZONING: B2FRONT ROYAL PIKE - U.S. ROUTE 522STOPSTOPSTOPSTOPSTOPSTOP LOT 1GARBER ESTATE SUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)ZONING: B2N46°13'28"E 367.43'COSTELLO DRIVE 34-1367ELOD LODLOD LOD LOD LOD LODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODWESNORTH ZONEVCS NAD83/2011LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLODLODLODLODLODLODLODLODLODLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWTHIS PLAN TO BE UTILIZEDFOR DEMOLITION PURPOSESONLY0SCALE:1" = 50'505012.525OVERALLEXISTINGCONDITIONS/DEMOLITIONPLANC-204 May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-EXDM-NJA220135.00-0A----->LAYOUT: C-204 OVERALL EXDMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-EXDMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026C-20C-208C-205C-206C-20HATCH LEGENDHATCHDESCRIPTIONEXISTING FCSA ESMT OR WATER ANDSANITARY SEWER TO BE VACATED FRONT ROYAL PIKE - U.S. ROUTE 522 TF(TBR)DO NOT ENTERSTOPSTOP 6" P V C ( T B R ) 27" RCP REVE R S E F L O W ( T B R )6" PVC (TBR)STORM MHRIM=725.26(TO BE CONVERTEDTO INLET)INV A=721.21INV B=721.16GRATE INLET (TBR)RIM=717.05INV A=715.05INV B=713.55INV C=713.50BAGRATE INLET (TBR)RIM=717.90INV=716.50CURB INLET (TBR)RIM=718.36INV A=712.36INV B=712.16BAGRATE INLET (TBR)RIM=723.28INV=720.53(RECESSED PIPE)MH STORM (TBR)RIM=723.35INV=720.70BOTTOM=±715.9GRATE INLET (TBR)RIM=723.10; BOTTOM=±721.3(RECESSED PIPES)MH STORM (TBR)RIM=723.28INV=720.43BOTTOM=±715.8STOP STOP STOP STOP STOP STOP APPROX. LOC. 30' WATER & SEWEREASEMENTD.B. 838 PG. 1360 (TBV)ASPHALTPAVEMENT(TBR)ASPHALTPAVEMENT(TBR)CONCPAVEMENT(TBR)ADARAMP(TBR)CONC WALK(TBR)CONC CONCISLAND(TBR)N46°13'28"E 367.43'S60°23'46"E (R) S63°10'47"E (M) 290.40' (R&M)N49 ° 0 0 ' 2 9 " E ( R ) N46 ° 1 3 ' 2 8 " E ( M ) 159. 0 0 ' ( R & M )6.2'x12.0'GAS ATTENDANTSBUILDING (TBR)CA R T C O R R A L ( T B R )CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR) CONC CURB (TBR) CONC CURB (TBR)CONC CURB (TBR) CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR)SOLID WHITE LINE (TYP) (TBR)SOLID WHITE LINE(TYP) (TBR)SOLID WHITE LINE(TYP) (TBR)SO L I D W H I T E L I N E ( T Y P ) ( T B R ) SO L I D W H I T E L I N E ( T Y P )DASHED WHITE LINE (TYP) (TBR)DISPENSER ISLAND(TYP) (TBR)GAS COVERS(TYP) (TBR)SHUT OFF SWITCH (TBR)SHUT OFFSWITCH (TBR)DASHED WHITE LINE (TYP) (TBR)CART CORRAL (TBR)ADA SIGN(TYP)(TBR)STOPSIGN (TBR)STOPSIGN(TBR)LSA(TBR)LSA(TBR)LSA(TBR)LSA(TBR)LSA (TBR)LSA(TBR)LSA(TBR)LSA(TBR)GRASS (TBR)VANVENTPIPES(TBR)CANOPY (TBR)CANOPY (TBR)APPROX. LOC. OFUNDERGROUNDTANKS (TBR)COVER (TBR)UNKNOWNSIZE (TBR)CONC CURB (TBR)PROP. SAWCUTLIMITS OF DISTURBANCE = 12.85 AC718.9319.7'19.9'18.1'18.7'19.7'19.8'18.4'19.6'5.0'29.9'9 .8 ' 19.5'21.0'LOD LOD LOD LODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP. SAWCUTTC 724.67TC 724.71TC 724.54TC 724.41TC 723.87TC 723.17TC 722.76TC 723.99TC 719.61TC 721.00TC 720.16TC 718.15TC 718.55TC 718.44TC 718.37TC 720.20TC 720.71TC 719.99TC 719.75TC 721.68TC 721.65TC 723.56TC 724.77TC 724.71TC 724.10TC 721.04TC 720.49TC 720.66TC 721.46TC 720.63TC 718.69TC 718.52TC 718.82TC 718.91TC 718.53TC 718.89TC 720.49TC 719.58TC 721.72TC 720.99TC 721.69G 724.30G 724.33G 724.22G 723.94G 723.34G 722.64G 722.22G 717.82G 719.30G 719.71G 720.63G 723.72G 723.82G 724.23G 724.42G 723.19G 721.18G 721.32G 719.86G 719.52G 719.73G 720.34G 718.07G 718.10G 718.18G 718.17G 718.31G 718.34G 720.68G 720.24G 720.11G 721.12G 720.43G 721.28G 721.49G 720.47G 720.10G 719.05G 717.98G 718.67G 718.48722.70721.57724.22718.85TC 718.48G 718.07TC 718.87G 718.37TC 724.03G 723.768" D IP (TBR)8" DIP (TBR)8" DIP (TBR)8" DIP (TBR)DO NOTENTERSIGN(TBR)WESNORTH ZONEVCS NAD83/2011LIGHT (TBR)(TYP)BOLLARD (TBR)(TYP)98.9'C/O(TBR)(TYP)GAS STATION STRIPING(TYP)(TBR)LOW HYDRANT (TBR)LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWSTRIPING(TYP)(TBR)PAVEMENT MARKINGS (TBR)WATERLINE (TBR)STOP BAR (TYP) (TBR)CONC CURB &GUTTER (TBR)CONC WALK LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWPROP. SAWCUTSIGN (TO BERELO)THIS PLAN TO BE UTILIZEDFOR DEMOLITION PURPOSESONLY0SCALE:1" = 20'2020510EXISTINGCONDITIONS/DEMOLITIONPLANC-205 May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-EXDM-NJA220135.00-0A----->LAYOUT: C-205 EXDMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-EXDMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - SHEETC-206DEMOLITION NOTES:1.CONTRACTOR TO COORDINATE DISCONNECTION OFTELECOM LINE WITH TELECOMMUNICATION COMPANYPRIOR TO DEMOLITION.2.CONTRACTOR TO MAINTAIN MINIMUM COVER OVEREXISTING UTILITIES WHICH ARE TO REMAIN. EXISTINGUTILITY BOX COVERS AND MANHOLE LIDS SHALL BERESET TO PROPOSED GRADE AS NECESSARY.3.CONTRACTOR TO COORDINATE DISCONNECTION OFUNDERGROUND POWER LINES, AND TRANSFORMER WITHPOWER COMPANY PRIOR TO DEMOLITION.4.CONTRACTOR TO REMOVE STRIPING BY GRINDING OROTHER METHOD TO LEAVE ASPHALT IN PLACE, AREASDELINEATED AS LIMITS OF WORK.5.CONTRACTOR SHALL REMOVE ALL UNUTILIZEDFREDERICK WATER FACILITIES AND FURNISH ITEMS TOTHE FREDERICK WATER INSPECTOR AS REQUIRED.CLEARING AND GRUBBING NOTES:1.ALL TREES, STUMPS, ROOT BALLS, AND OTHERVEGETATIVE MATTER EXCEEDING ONE (1) INCH INDIAMETER SHALL BE REMOVED WITHIN THE LIMITS OFCLEARING AND GRUBBING. ALL CROPS SHALL BE CUTAND REMOVED. BRUSH, WASTE LOGS, LIMBS, TIMBERTOPS, AND ALL DEBRIS RESULTING FROM CLEARING,GRUBBING, OR LOGGING OPERATIONS SHALL BEREMOVED FROM THE SITE AND DISPOSED OF INACCORDANCE WITH APPLICABLE REGULATIONS.2.SOILS WITHIN AREAS PREVIOUSLY USED FORAGRICULTURAL PURPOSES SHALL BE RAKED TO AMINIMUM DEPTH OF TWENTY-FOUR (24) INCHES TOREMOVE ROOTS AND ORGANIC MATERIAL.3.ALL TOPSOIL AND SOIL CONTAINING MORE THAN TWO (2)PERCENT ORGANICS BY WEIGHT SHALL BE STRIPPED ANDREMOVED FROM THE SITE. WHERE TOPSOIL COMPOSITIONAND SITE GRADING WILL RESULT IN DISPERSAL OFORGANICS AND WILL NOT AFFECT COMPACTION,SUBGRADE STIFFNESS, OR CAUSE SETTLEMENT, IT MAYBE PERMISSIBLE TO UTILIZE SOILS WITH A HIGHERORGANIC CONTENT. SUCH USE MUST BE RECOMMENDEDBY THE GEOTECHNICAL ENGINEER, BE SUPPORTED BYTESTING OUTLINED IN SECTION 16, AND MUST BEAPPROVED BY COSTCO WHOLESALE. IN NO CASE WILLUSE OF SOIL CONTAINING MORE THAN FIVE (5) PERCENTORGANICS BY WEIGHT BE ALLOWED. IF EXISTING TOPSOILIS DEEMED SUITABLE FOR RE-USE, BY THE COSTCOWHOLESALE LANDSCAPE ARCHITECT, THE MATERIAL MAYBE STOCKPILED ONSITE IN A LOCATION APPROVED BYCOSTCO WHOLESALE.HATCH LEGENDHATCHDESCRIPTIONEXISTING FCSA ESMT OR WATER ANDSANITARY SEWER TO BE VACATED FRONT ROYAL PIKE - U.S. ROUTE 522DO NOT ENTERSTOP15" RCP (TBR)15" RCP (TBR)15" RC P (TBR)24" RCP (TBR)15" RCP (TBR)8" PVC (TBR)27" RCP (TBR)27" RCP (TBR)27" RCP (TBR)6" P V C ( T B R ) 27" RCP REVE R S E F L O W ( T B R )15" RCPCURB INLET (TBR)RIM=722.45INV=716.20ABCURB INLET (TBR)RIM=717.68INV A=710.78INV B=710.68INV C=710.48INV D=710.38DCABCURB INLET (TBR)RIM=717.82INV A=712.82INV B=712.42ABCURB INLET (TBR)RIM=717.57INV=710.77CURB INLET (TBR)RIM=715.44INV=708.34ABCACURB INLET (TBR)RIM=716.01INV A=710.26INV B=710.21BAGRATE INLET (TBR)RIM=717.05INV A=715.05INV B=713.55INV C=713.50BACRIM=723.28INV=720.43BOTTOM=±715.8BENCHMARKX-CUT SETELEV.=720.69 (TBR)STOPCOVER (TBR)ICVGRATE INLET (TBR)RIM=716.74(FULL OF DEBRIS)ASPHALTPAVEMENT(TBR)ASPHALTPAVEMENT(TBR)ASPHALTPAVEMENT(TBR)ASPHALTPAVEMENT(TBR)ASPHALTPAVEMENT(TBR)ADARAMP(TBR)CONC WALK (TBR)CONC WALK(TBR)N46°13'28"E 367.43'CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR) CONC CURB (TBR)CONC CURB (TBR) CONC CURB (TBR) CONC CURB ( T B R ) CONC CURB (TBR) CONC CURB (TBR)CONC CURB (TBR)CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR)SOLID WHITE LINE (TYP) (TBR)SOLID WHITE LINE (TYP) (TBR)SOLID WHITE LINE (TYP) (TBR)SOLID WHITE LINE(TYP) (TBR)SO L I D W H I T E L I N E ( T Y P ) ( T B R ) SO L I D W H I T E L I N E ( T Y P ) ( T B R ) SO L I D W H I T E L I N E (TY P ) ( T B R ) SOLID WHITE LINE (TYP) (TBR)DISPENSER ISLAND(TYP) (TBR)SHUT OFFSWITCH (TBR)CA R T C O R R A L ( T B R )CART CORRAL (TBR)CART CORRAL (TBR)CART CORRAL (TBR)CART CORRAL (TBR)ADA SIGN(TYP)(TBR)ADA SIGN(TYP)(TBR)STOP SIGN (TBR)LSA(TBR)LSA(TBR)LSA(TBR)LSA(TBR)LSA (TBR)LSA(TBR)LSA(TBR)LSA(TBR)LSA(TBR)LSA (TBR)LSA (TBR)LSA(TBR)LSA(TBR)LSA (TBR)GRASS (TBR)GRASS (TBR)CURB INLET (TBR)RIM=714.74INV A=709.19INV B=709.04INV C=708.84CURB INLET (TBR)RIM=721.42INV A=716.32INV B=716.27VANSOLID WHITE LINE (TYP) (TBR)COVER (TBR)POSSIBLEREVERSEFLOWVANVANCONC CURB (TBR)PROP. SAWCUT9.6'19.7'TC 715.80TC 715.69TC 722.76TC 720.45TC 717.78TC 716.04TC 717.10TC 715.26TC 716.69G 715.27G 715.25G 722.10G 719.93G 717.11G 716.55G 715.54G 714.81G 716.29717.5716.4716.48TC 715.22G 714.7819.7'19.9'18.1'19.9'19.6'18.4'20.0'19.8'20.1'18.3'5.0'19.9'24.3'19.9'12.1'10.7'10.0'10.7'10.0'9.4'29.9'9.8 ' 19.4'19.5'21.0'LOD LOD LOD LOD LODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP.SAWCUT12.6'TC 718.47TC 720.64TC 721.34TC 721.82TC 724.67TC 722.49TC 722.62TC 723.23TC 723.53TC 721.86TC 721.77TC 721.61TC 722.08TC 720.14TC 720.16TC 716.78TC 718.15TC 718.17TC 715.97TC 716.24TC 717.67TC 717.83TC 717.83TC 718.50TC 719.94TC 723.42TC 723.19TC 723.80TC 723.84TC 723.84TC 723.99TC 720.40TC 720.89TC 719.19TC 719.61TC 720.41TC 721.00TC 720.16TC 719.29TC 717.94TC 718.15TC 717.94TC 717.78TC 718.55TC 718.44TC 718.37TC 720.20TC 720.71TC 719.99TC 719.75TC 721.68TC 721.65TC 723.56TC 724.77TC 724.71TC 724.10G 718.18G 720.14G 720.90G 721.28G 724.30G 715.64G 715.71G 716.30G 717.66G 717.79G 719.65G 719.70G 721.46G 721.42G 721.56G 721.68G 722.27G 722.10G 722.98G 723.13G 722.78G 723.43G 722.98G 723.45G 718.18G 719.47G 717.24G 717.29G 717.52G 717.43G 717.63G 717.40G 717.58G 717.82G 718.96G 718.91G 719.30G 719.71G 720.63G 719.94G 720.16G 720.62G 723.38G 723.72G 723.82G 724.23G 724.42G 723.19G 721.18G 721.32G 719.86G 719.52G 719.73G 720.34G 718.07G 718.10G 718.18720.38TC 716.48G 716.15TC 717.81TC 718.48G 718.07TC 715.99G 715.74TC 723.57G 723.14TC 723.90TC 724.03G 723.49G 723.768" DIP (TBR)8" DIP (TBR)8" DIP (TBR)PROP. SAWCUTPROP. SAWCUTCOSTELLO DRIVE 34-1367ER=50.00' (R&M)Δ=101°34'27" (R&M)L=88.64' (R&M)CHB=N01°46'45"W (R)CHB=N04°33'46"W (M)CHD=77.48' (R&M)WESNORTH ZONEVCS NAD83/2011LIGHT (TBR)(TYP)BOLLARD (TBR)(TYP)LOW LOW LOW HYDRANT (TBR)PAVEMENT STRIPING(TYP)(TBR)PAVEMENT STRIPING(TYP)(TBR)LOWLOWLOWWATERLINE (TBR)STOP BAR (TYP) (TBR)CONC WALK(TBR)CONC CURB & GUTTER (TBR)TOTAL LIMITS OF DISTURBANCE = 12.85 ACLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLO D LO DPROP ROWLOWLOW LOW LOW LOW LOW LOW LOW LOW LOW LOWPROP. SAWCUTSIGN (TO BERELO)CONC WALK (TBR)PROP.SAWCUTTHIS PLAN TO BE UTILIZEDFOR DEMOLITION PURPOSESONLY0SCALE:1" = 20'2020510EXISTINGCONDITIONS/DEMOLITIONPLANC-206 May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-EXDM-NJA220135.00-0A----->LAYOUT: C-206 EXDMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-EXDMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - SHEET C-207 MATCHLINE - SHEETC-205DEMOLITION NOTES:1.CONTRACTOR TO COORDINATE DISCONNECTION OFTELECOM LINE WITH TELECOMMUNICATION COMPANYPRIOR TO DEMOLITION.2.CONTRACTOR TO MAINTAIN MINIMUM COVER OVEREXISTING UTILITIES WHICH ARE TO REMAIN. EXISTINGUTILITY BOX COVERS AND MANHOLE LIDS SHALL BERESET TO PROPOSED GRADE AS NECESSARY.3.CONTRACTOR TO COORDINATE DISCONNECTION OFUNDERGROUND POWER LINES, AND TRANSFORMER WITHPOWER COMPANY PRIOR TO DEMOLITION.4.CONTRACTOR TO REMOVE STRIPING BY GRINDING OROTHER METHOD TO LEAVE ASPHALT IN PLACE, AREASDELINEATED AS LIMITS OF WORK.5.CONTRACTOR SHALL REMOVE ALL UNUTILIZEDFREDERICK WATER FACILITIES AND FURNISH ITEMS TOTHE FREDERICK WATER INSPECTOR AS REQUIRED.CLEARING AND GRUBBING NOTES:1.ALL TREES, STUMPS, ROOT BALLS, AND OTHERVEGETATIVE MATTER EXCEEDING ONE (1) INCH INDIAMETER SHALL BE REMOVED WITHIN THE LIMITS OFCLEARING AND GRUBBING. ALL CROPS SHALL BE CUTAND REMOVED. BRUSH, WASTE LOGS, LIMBS, TIMBERTOPS, AND ALL DEBRIS RESULTING FROM CLEARING,GRUBBING, OR LOGGING OPERATIONS SHALL BEREMOVED FROM THE SITE AND DISPOSED OF INACCORDANCE WITH APPLICABLE REGULATIONS.2.SOILS WITHIN AREAS PREVIOUSLY USED FORAGRICULTURAL PURPOSES SHALL BE RAKED TO AMINIMUM DEPTH OF TWENTY-FOUR (24) INCHES TOREMOVE ROOTS AND ORGANIC MATERIAL.3.ALL TOPSOIL AND SOIL CONTAINING MORE THAN TWO (2)PERCENT ORGANICS BY WEIGHT SHALL BE STRIPPED ANDREMOVED FROM THE SITE. WHERE TOPSOIL COMPOSITIONAND SITE GRADING WILL RESULT IN DISPERSAL OFORGANICS AND WILL NOT AFFECT COMPACTION,SUBGRADE STIFFNESS, OR CAUSE SETTLEMENT, IT MAYBE PERMISSIBLE TO UTILIZE SOILS WITH A HIGHERORGANIC CONTENT. SUCH USE MUST BE RECOMMENDEDBY THE GEOTECHNICAL ENGINEER, BE SUPPORTED BYTESTING OUTLINED IN SECTION 16, AND MUST BEAPPROVED BY COSTCO WHOLESALE. IN NO CASE WILLUSE OF SOIL CONTAINING MORE THAN FIVE (5) PERCENTORGANICS BY WEIGHT BE ALLOWED. IF EXISTING TOPSOILIS DEEMED SUITABLE FOR RE-USE, BY THE COSTCOWHOLESALE LANDSCAPE ARCHITECT, THE MATERIAL MAYBE STOCKPILED ONSITE IN A LOCATION APPROVED BYCOSTCO WHOLESALE.HATCH LEGENDHATCHDESCRIPTIONEXISTING FCSA ESMT OR WATER ANDSANITARY SEWER TO BE VACATED STOPSTOP27" RCP (TBR)27" RCP (TBR)6" PVC (TBR)15" RCP42"x27" RCP (TBR)42"x27" RCP (TBR)18" RCP (TBR)15" RCP (TBR)50"x 3 1 " R C P ( T B R )CURB INLET (TBR)RIM=715.44INV=708.34ABCABCBCACURB INLET (TBR)RIM=712.96INV=705.96CURB INLET (TBR)RIM=711.89INV A=704.09INV B=704.04INV C=703.94ACBCURB INLET (TBR)RIM=711.10INV=704.4BAINV=703.4612" ORIFICE (TBR)INV=703.58ICVICV (TBR)COVERS(TBR)ASPHALTPAVEMENT(TBR)ASPHALTPAVEMENT(TBR)ASPHALTPAVEMENT(TBR)ADARAMP(TBR)CONC WALK (TBR)CONC WALK (TBR)ADA RAMP(TBR)CONC WALK (TBR)N52°33'58"W (R) N55°20'59"W (M) 839.11' (R&M)RAISEDCONC WALK(TBR)CONC CURB (TBR) CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)(TYP)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB (TBR)CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR) (TYP)CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR)SOLID WHITE LINE(TYP) (TBR)SOLID WHITE LINE (TYP) (TBR)SOL ID WH ITE L INE (TYP ) (TBR )SOLID WH ITE L INE (TYP ) (TBR )SOLID WHITE LINE (TYP) (TBR)SOLID WHITE LINE (TYP) (TBR)SOLID WHITE LINE (TYP) (TBR)CART CORRAL (TBR)CART CORRAL (TBR)CART CORRAL (TBR)4' CHAINLINK FENCE (TBR)ADA SIGN(TBR)ADA SIGN(TYP) (TBR)ADA SIGN(TYP) (TBR)ADA SIGN(TYP) (TBR)STOP SIGN (TBR)LSA(TBR)LSA(TBR)LSA(TBR)LSA (TBR)LSA(TBR)LSA(TBR)LSA(TBR)LSA(TBR)LSA(TBR)LSA(TBR)LSA(TBR)LSA (TBR)LSA(TBR)LSA(TBR)LSA(TBR)LSA(TBR)GRASS(TBR)GRASS (TBR)GRASS (TBR)CURB INLET (TBR)RIM=714.74INV A=709.19INV B=709.04INV C=708.84CURB INLET (TBR)RIM=715.75INV A=707.98INV B=707.20INV C=707.152xC/O2xC/OGREASE TRAP(TBR)VANVANCURB INLET (TBR)RIM=713.19INV A=705.59INV B=705.54INV C=705.49SOLID WHITE L I N E (TYP) (TBR)GAS MARKER (TBR)GRASS(TBR)COSTELLO DRIVE 34-1367EVANVANVANVAN LOT 1GARBER ESTATESUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)EX. RETENTIONPOND (TBR)TC 715.80TC 715.10TC 715.49TC 713.88TC 712.85TC 711.86TC 711.10TC 715.26G 715.27G 715.02G 714.62G 713.38G 712.32G 711.41G 710.25G 714.81719.11719.16718.93TC 715.22G 714.7829.9'17.0'20.2'19.5'18.4'19.7'19.9'18.0'19.8'20.5'17.7'20.4'19.9'18.0'20.0'19.7'18.6'19.7'20.0'18.3'19.7'10.0'9.9'9.8'PROP. SAWCUTLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTOTAL LIMITS OF DISTURBANCE = 12.85 ACPROP. SAWCUTTC 711.84TC 712.69TC 713.28TC 713.63TC 714.21TC 714.48TC 714.40TC 716.48TC 717.80TC 718.14TC 718.34TC 717.53TC 714.83TC 713.66TC 713.50TC 713.50TC 713.77TC 713.49TC 713.82TC 713.66TC 713.74TC 714.07TC 714.11TC 714.26TC 714.07TC 714.73TC 714.26TC 714.68TC 714.35TC 714.90TC 714.58TC 714.83TC 714.70TC 715.18TC 714.84TC 714.68TC 715.13TC 718.21TC 718.26TC 718.35TC 718.25TC 718.42TC 718.35TC 718.14TC 718.15TC 718.34TC 718.30TC 718.20TC 718.26TC 718.02TC 718.03TC 718.32TC 718.16TC 718.24TC 718.09TC 718.10TC 718.19TC 718.05TC 718.10TC 718.14TC 718.16TC 715.97TC 716.24TC 717.67TC 717.83TC 717.83TC 717.94TC 718.15TC 717.94TC 717.78TC 718.55TC 718.44TC 718.37G 711.24G 712.15G 712.75G 713.20G 713.68G 714.24G 714.22G 716.09G 717.44G 717.92G 717.85G 717.06G 714.29G 713.05G 713.25G 713.32G 713.13G 713.20G 713.44G 713.36G 713.45G 713.56G 713.76G 713.96G 713.73G 713.88G 714.32G 714.24G 713.79G 714.54G 714.04G 714.56G 714.34G 714.43G 714.86G 714.16G 714.89G 717.72G 717.96G 717.98G 717.75G 717.76G 718.06G 717.96G 717.83G 718.07G 717.84G 717.71G 717.85G 717.69G 717.82G 717.81G 717.72G 717.97G 717.69G 717.71G 717.87G 717.83G 717.87G 717.69G 717.69G 718.48TC 719.48G 715.64G 715.71G 717.24G 717.29G 717.52G 717.43G 717.63G 717.40G 717.58G 717.82G 718.07G 718.10G 718.18712.5706.1713.2704.1715.4717.8706.1706.5705.7718.13718.98712.60713.40713.88714.31716.83716.98717.11714.96715.48715.06715.80TC 716.48G 716.15TC 717.81TC 718.48G 718.07TC 715.99G 715.748" DIP (TBR)8" DIP (TBR)8" DIP (TBR)36.1'PROP. SAWCUT8" DIP (TBR)8" DIP (TBR)WESNORTH ZONEVCS NAD83/2011LIGHT (TBR)(TYP)232.7'PROP. SAWCUTBOLLARD (TBR)(TYP)PAVEMENT STRIPING(TBR)(TYP)TREES (TBR)CONC WALK (TBR)CONC WALK (TBR)CONC WALK (TBR)LODLOD LODPROP ROWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWSIGN(TBR)THIS PLAN TO BE UTILIZEDFOR DEMOLITION PURPOSESONLY0SCALE:1" = 20'2020510EXISTINGCONDITIONS/DEMOLITIONPLANC-207 May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-EXDM-NJA220135.00-0A----->LAYOUT: C-207 EXDMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-EXDMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - SHEET C-206 MATCHLINE - SHEET C-208 DEMOLITION NOTES:1.CONTRACTOR TO COORDINATE DISCONNECTION OFTELECOM LINE WITH TELECOMMUNICATION COMPANYPRIOR TO DEMOLITION.2.CONTRACTOR TO MAINTAIN MINIMUM COVER OVEREXISTING UTILITIES WHICH ARE TO REMAIN. EXISTINGUTILITY BOX COVERS AND MANHOLE LIDS SHALL BERESET TO PROPOSED GRADE AS NECESSARY.3.CONTRACTOR TO COORDINATE DISCONNECTION OFUNDERGROUND POWER LINES, AND TRANSFORMER WITHPOWER COMPANY PRIOR TO DEMOLITION.4.CONTRACTOR TO REMOVE STRIPING BY GRINDING OROTHER METHOD TO LEAVE ASPHALT IN PLACE, AREASDELINEATED AS LIMITS OF WORK.5.CONTRACTOR SHALL REMOVE ALL UNUTILIZEDFREDERICK WATER FACILITIES AND FURNISH ITEMS TOTHE FREDERICK WATER INSPECTOR AS REQUIRED.CLEARING AND GRUBBING NOTES:1.ALL TREES, STUMPS, ROOT BALLS, AND OTHERVEGETATIVE MATTER EXCEEDING ONE (1) INCH INDIAMETER SHALL BE REMOVED WITHIN THE LIMITS OFCLEARING AND GRUBBING. ALL CROPS SHALL BE CUTAND REMOVED. BRUSH, WASTE LOGS, LIMBS, TIMBERTOPS, AND ALL DEBRIS RESULTING FROM CLEARING,GRUBBING, OR LOGGING OPERATIONS SHALL BEREMOVED FROM THE SITE AND DISPOSED OF INACCORDANCE WITH APPLICABLE REGULATIONS.2.SOILS WITHIN AREAS PREVIOUSLY USED FORAGRICULTURAL PURPOSES SHALL BE RAKED TO AMINIMUM DEPTH OF TWENTY-FOUR (24) INCHES TOREMOVE ROOTS AND ORGANIC MATERIAL.3.ALL TOPSOIL AND SOIL CONTAINING MORE THAN TWO (2)PERCENT ORGANICS BY WEIGHT SHALL BE STRIPPED ANDREMOVED FROM THE SITE. WHERE TOPSOIL COMPOSITIONAND SITE GRADING WILL RESULT IN DISPERSAL OFORGANICS AND WILL NOT AFFECT COMPACTION,SUBGRADE STIFFNESS, OR CAUSE SETTLEMENT, IT MAYBE PERMISSIBLE TO UTILIZE SOILS WITH A HIGHERORGANIC CONTENT. SUCH USE MUST BE RECOMMENDEDBY THE GEOTECHNICAL ENGINEER, BE SUPPORTED BYTESTING OUTLINED IN SECTION 16, AND MUST BEAPPROVED BY COSTCO WHOLESALE. IN NO CASE WILLUSE OF SOIL CONTAINING MORE THAN FIVE (5) PERCENTORGANICS BY WEIGHT BE ALLOWED. IF EXISTING TOPSOILIS DEEMED SUITABLE FOR RE-USE, BY THE COSTCOWHOLESALE LANDSCAPE ARCHITECT, THE MATERIAL MAYBE STOCKPILED ONSITE IN A LOCATION APPROVED BYCOSTCO WHOLESALE.HATCH LEGENDHATCHDESCRIPTIONEXISTING FCSA ESMT OR WATER ANDSANITARY SEWER TO BE VACATED 15" RCP (TBR)50"x31" RCP (TBR)15" RCP (TBR)30" RCP (TBR)30" RCP (TBR)18" RCP (TBR)18" RCP (TBR)18" RCP (TBR)24" RCP (TBR)15" RCP (TBR)CURB INLET (TBR)RIM=711.89INV A=704.09INV B=704.04INV C=703.94ACBCURB INLET (TBR)RIM=711.10INV=704.4ACONC STORMSTRUCTURE (TBR)TOP=708.05INV=699.2515" ORIFICE (TBR)INV=699.98INV=700.98 (TBR)INV=703.15 (TBR)CURB INLET (TBR)RIM=711.28INV=705.78CURB INLET (TBR)RIM=711.17INV A=705.17INV B=705.07INV=704.97INV=703.46INV=705.69 (TBR)CONC STORMSTRUCTURE(TBR)TOP=709.06INV=703.4112" ORIFICE (TBR)INV=703.58CURB INLET (TBR)RIM=714.66INV A=706.26INV B=706.16BACURB INLET (TBR)RIM=714.60INV A=707.40INV B=707.25INV B=712.07CURB INLET (TBR)RIM=707.39INV A=701.54INV B=701.49BABABCOSTELLO DR IVE 34 -1367EICV (TBR)COVERS(TBR)COVER (TBR)ICV (TBR)COVER(TBR)ASPHALTPAVEMENT(TBR)CONCPAVEMENT(TBR)ASPHALTPAVEMENT(TBR)ASPHALTPAVEMENT(TBR)ADARAMP(TBR)ADARAMP(TBR)ADA RAMP (TBR)ADA RAMP (TBR)CONC WALK (TBR)CONC WALK (TBR)S22°42'25"W (R) S19°55'24"W (M) 458.80' (R&M)127.7'RAISEDCONC WALK(TBR)CONC CURB (TBR)CONC CURB (TBR)CONCCURB(TBR)CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR )EDGE OF PAVEMENT (TBR ) SOLID YELLOW LINE (TBR)SOLID WHITE LINE(TYP) (TBR)4' WIRE FENCE (TBR)FENCE IS 1.9'EAST OF ⅊ (TBR)FENCE CROSSES ⅊STONEPILE(TBR)4' CHAINLINK FENCE (TBR)STOPSIGN(TBR)GRASS (TBR)GRASS (TBR)GRASS(TBR)2xC/O2xC/OGREASE TRAP(TBR)GRASS (TBR)GRASS(TBR)GRASS (TBR)GRASS (TBR)S29°36'14"W (R)S26°49'13"W (M)668.42' (R&M)PROP. SAWCUTCONC WALK (TBR)EDGE OF PAVEMENT (TBR)EX. RETENTIONPOND (TBR)TC 710.32TC 708.80TC 707.33TC 704.86TC 710.52TC 711.10TC 710.66G 709.88G 708.27G 706.68G 704.37G 710.25G 710.00G 710.1436.2'17.0'CURB INLET (TBR)RIM=702.62INV A = 699.27INV B=695.77TREELINE (TBR)LOD LODLODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP. SAWCUTTC 717.79TC 717.03TC 714.92TC 711.60TC 704.63TC 704.30TC 703.84TC 701.40TC 719.13TC 718.17TC 711.84TC 710.86TC 712.86TC 714.88TC 718.10TC 718.34TC 717.53TC 714.83TC 713.66G 717.26G 716.50G 714.48G 711.05G 703.85G 704.30G 703.83G 701.34G 718.76G 717.79G 711.24G 710.40G 712.34G 714.14G 717.63G 717.85G 717.06G 714.29G 713.25G 718.48G 716.79TC 717.80TC 719.48708.1701.1707.5701.3707.0700.9700.7707.7701.0700.3709.1711.5707.0705.5704.3703.6703.7706.1706.4708.3711.0708.5709.2712.5706.1713.2705.6704.1712.5715.4717.8717.2715.4706.1706.5705.7718.13717.51717.69715.66718.24718.98712.60715.80TC 717.90G 717.398" DIP (TBR)8" DIP (TBR)R=460.00' (R&M)Δ=031°52'40" (R&M)L=255.93' (R&M)CHB=S68°30'18"E (R)CHB=N71°17'19"W (M)CHD=252.64' (R&M)R=1040.00' (R&M)Δ=008°18'13" (R&M)L=150.72' (R&M)CHB=N80°17'31"W (R)CHB=N83°04'32"W (M)CHD=150.59' (R&M)N84°26'38"W (R)N87°13'39"W (M)129.72' (R&M)WESNORTH ZONEVCS NAD83/2011INV A=703.68(TBR)PAVEMENT STRIPING(TBR)(TYP)WATER (TBR)TELEPHONE (TBR)PROP ROWPROP ROWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWTOTAL LIMITS OFDISTURBANCE = 12.85 ACSIGN(TBR)THIS PLAN TO BE UTILIZEDFOR DEMOLITION PURPOSESONLY0SCALE:1" = 20'2020510EXISTINGCONDITIONS/DEMOLITIONPLANC-208 May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-EXDM-NJA220135.00-0A----->LAYOUT: C-208 EXDMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-EXDMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - SHEETC-209MATCHLINE - SHEET C-207 DEMOLITION NOTES:1.CONTRACTOR TO COORDINATE DISCONNECTION OFTELECOM LINE WITH TELECOMMUNICATION COMPANYPRIOR TO DEMOLITION.2.CONTRACTOR TO MAINTAIN MINIMUM COVER OVEREXISTING UTILITIES WHICH ARE TO REMAIN. EXISTINGUTILITY BOX COVERS AND MANHOLE LIDS SHALL BERESET TO PROPOSED GRADE AS NECESSARY.3.CONTRACTOR TO COORDINATE DISCONNECTION OFUNDERGROUND POWER LINES, AND TRANSFORMER WITHPOWER COMPANY PRIOR TO DEMOLITION.4.CONTRACTOR TO REMOVE STRIPING BY GRINDING OROTHER METHOD TO LEAVE ASPHALT IN PLACE, AREASDELINEATED AS LIMITS OF WORK.5.CONTRACTOR SHALL REMOVE ALL UNUTILIZEDFREDERICK WATER FACILITIES AND FURNISH ITEMS TOTHE FREDERICK WATER INSPECTOR AS REQUIRED.CLEARING AND GRUBBING NOTES:1.ALL TREES, STUMPS, ROOT BALLS, AND OTHERVEGETATIVE MATTER EXCEEDING ONE (1) INCH INDIAMETER SHALL BE REMOVED WITHIN THE LIMITS OFCLEARING AND GRUBBING. ALL CROPS SHALL BE CUTAND REMOVED. BRUSH, WASTE LOGS, LIMBS, TIMBERTOPS, AND ALL DEBRIS RESULTING FROM CLEARING,GRUBBING, OR LOGGING OPERATIONS SHALL BEREMOVED FROM THE SITE AND DISPOSED OF INACCORDANCE WITH APPLICABLE REGULATIONS.2.SOILS WITHIN AREAS PREVIOUSLY USED FORAGRICULTURAL PURPOSES SHALL BE RAKED TO AMINIMUM DEPTH OF TWENTY-FOUR (24) INCHES TOREMOVE ROOTS AND ORGANIC MATERIAL.3.ALL TOPSOIL AND SOIL CONTAINING MORE THAN TWO (2)PERCENT ORGANICS BY WEIGHT SHALL BE STRIPPED ANDREMOVED FROM THE SITE. WHERE TOPSOIL COMPOSITIONAND SITE GRADING WILL RESULT IN DISPERSAL OFORGANICS AND WILL NOT AFFECT COMPACTION,SUBGRADE STIFFNESS, OR CAUSE SETTLEMENT, IT MAYBE PERMISSIBLE TO UTILIZE SOILS WITH A HIGHERORGANIC CONTENT. SUCH USE MUST BE RECOMMENDEDBY THE GEOTECHNICAL ENGINEER, BE SUPPORTED BYTESTING OUTLINED IN SECTION 16, AND MUST BEAPPROVED BY COSTCO WHOLESALE. IN NO CASE WILLUSE OF SOIL CONTAINING MORE THAN FIVE (5) PERCENTORGANICS BY WEIGHT BE ALLOWED. IF EXISTING TOPSOILIS DEEMED SUITABLE FOR RE-USE, BY THE COSTCOWHOLESALE LANDSCAPE ARCHITECT, THE MATERIAL MAYBE STOCKPILED ONSITE IN A LOCATION APPROVED BYCOSTCO WHOLESALE.HATCH LEGENDHATCHDESCRIPTIONEXISTING FCSA ESMT OR WATER ANDSANITARY SEWER TO BE VACATED LOT 2GARBER ESTATE SUBDIVISIOND.B. 838 PG. 1360LANDS OFCOSTCO WHOLESALE CORPORATIONINSTR. #190006190TM: 64-8-2AREA: 4.293 AC. (R&M)OR 187,007 S.F. (M)"NO BUILDINGS"ZONING: B215" RCP (TBR)15" DIP (TBR)CURB INLET (TBR)RIM=717.97INV=713.27GRATE INLET (TBR)RIM=715.07INV A=712.22INV B=712.07CBAABSAN MHRIM=718.19INV=709.94 (TBR)T-PED(TBR)LOT 1GARBER ESTATE SUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)ZONING: B2APPROX. LOC. 30'WATER & SEWER EASEMENT (TBV)D.B. 838 PG. 1360D.B. 838 PG. 1470ASPHALTPAVEMENT(TBR)CONCPAVEMENT(TBR)S60°23'46"E (R) S63°10'47"E (M) 852.51' (R&M)S23°22'33"W (R)S20°35'32"W (M)82.25' (R&M)S22°42'25"W (R) S19°55'24"W (M) 458.80' (R&M)59.6'CONC CURB (TBR)CONC CURB (TBR)CONCCURB(TBR)CONC WALK (TBR)CONC STEPS(TBR)CONC PAVEMENT(TRASH COMPACTORS)(TBR)TRENCH DRAIN (TBR)RIM=717.87(FULL OF DEBRIS)CONC CURB & GUTTER (TBR)CONC CURB & GUTTER (TBR)SOLID YELLOW LINE (TBR)SOLID YELLOW LINE (TBR)SOLID WHITE LINE(TYP) (TBR)⅊DILAPIDATED WIRE FENCE (TBR)4' WIRE FENCE (TBR)FENCE IS 0.3'WEST OF ⅊(TBR)18" RCP (TBR)GRASS (TBR)GRASS(TBR)GRASS(TBR)APPROX. LOC. 20'WATER EASEMENT (TBV)D.B. 838 PG. 1360D.B. 838 PG. 1470CURB INLET (TBR)RIM=717.32INV A=712.17INV B=711.67INV C=711.52GRASS (TBR)GRASS (TBR)APPROX. LOC. 10'POTOMAC EDISON COMPANY OFVIRGINIA EASEMENT (TBV)D.B. 836 PG. 1666POSSIBLEREVERSE FLOWS29°36'14"W (R)S26°49'13"W (M)668.42' (R&M)CONC CURB(TBR)BENCHMARKX-CUT SETELEV.=717.27 (TBR)PROP. SAWCUTTOTAL LIMITS OF DISTURBANCE = 12.85 ACCONC CURB & GUTTER (TBR)TRANSFORMER (TBR)BOLLARD (TYP) (TBR)LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTC 718.26TC 717.85TC 718.87TC 717.25TC 718.78TC 719.13TC 718.17TC 718.17G 717.82G 717.26G 718.46G 716.62G 718.76G 717.79G 718.64G 718.22G 715.16G 716.79G 715.18TC 716.18TC 717.80TC 716.16706.1706.4711.0708.5709.2710.3711.2710.3712.9714.7713.2713.4716.0715.9717.4718.4718.3717.2718.8720.0720.5721.9720.8718.09718.02718.38715.66TC 718.51G 718.00TC 717.90G 717.39TC 718.77G 718.58TRENCH DRAIN (TBR)RIM=±715.2(NO ACCESS, UNDERPALLETS/DEBRIS)8" DIP (TBR)8" DIP (TBR)8" DIP (TBR)8" DIP (TBR)8" DIP (TBR)8" DIP (TBR)8" DIP (TBR)8" DIP (TBR)WESNORTH ZONEVCS NAD83/2011LIGHT (TBR) (TYP)HYDRANT (TBR)EX FDC(TO REMAIN)59.3'THIS PLAN TO BE UTILIZEDFOR DEMOLITION PURPOSESONLY0SCALE:1" = 20'2020510EXISTINGCONDITIONS/DEMOLITIONPLANC-209 May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-EXDM-NJA220135.00-0A----->LAYOUT: C-209 EXDMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-EXDMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - SHEETC-208DEMOLITION NOTES:1.CONTRACTOR TO COORDINATE DISCONNECTION OFTELECOM LINE WITH TELECOMMUNICATION COMPANYPRIOR TO DEMOLITION.2.CONTRACTOR TO MAINTAIN MINIMUM COVER OVEREXISTING UTILITIES WHICH ARE TO REMAIN. EXISTINGUTILITY BOX COVERS AND MANHOLE LIDS SHALL BERESET TO PROPOSED GRADE AS NECESSARY.3.CONTRACTOR TO COORDINATE DISCONNECTION OFUNDERGROUND POWER LINES, AND TRANSFORMER WITHPOWER COMPANY PRIOR TO DEMOLITION.4.CONTRACTOR TO REMOVE STRIPING BY GRINDING OROTHER METHOD TO LEAVE ASPHALT IN PLACE, AREASDELINEATED AS LIMITS OF WORK.5.CONTRACTOR SHALL REMOVE ALL UNUTILIZEDFREDERICK WATER FACILITIES AND FURNISH ITEMS TOTHE FREDERICK WATER INSPECTOR AS REQUIRED.CLEARING AND GRUBBING NOTES:1.ALL TREES, STUMPS, ROOT BALLS, AND OTHERVEGETATIVE MATTER EXCEEDING ONE (1) INCH INDIAMETER SHALL BE REMOVED WITHIN THE LIMITS OFCLEARING AND GRUBBING. ALL CROPS SHALL BE CUTAND REMOVED. BRUSH, WASTE LOGS, LIMBS, TIMBERTOPS, AND ALL DEBRIS RESULTING FROM CLEARING,GRUBBING, OR LOGGING OPERATIONS SHALL BEREMOVED FROM THE SITE AND DISPOSED OF INACCORDANCE WITH APPLICABLE REGULATIONS.2.SOILS WITHIN AREAS PREVIOUSLY USED FORAGRICULTURAL PURPOSES SHALL BE RAKED TO AMINIMUM DEPTH OF TWENTY-FOUR (24) INCHES TOREMOVE ROOTS AND ORGANIC MATERIAL.3.ALL TOPSOIL AND SOIL CONTAINING MORE THAN TWO (2)PERCENT ORGANICS BY WEIGHT SHALL BE STRIPPED ANDREMOVED FROM THE SITE. WHERE TOPSOIL COMPOSITIONAND SITE GRADING WILL RESULT IN DISPERSAL OFORGANICS AND WILL NOT AFFECT COMPACTION,SUBGRADE STIFFNESS, OR CAUSE SETTLEMENT, IT MAYBE PERMISSIBLE TO UTILIZE SOILS WITH A HIGHERORGANIC CONTENT. SUCH USE MUST BE RECOMMENDEDBY THE GEOTECHNICAL ENGINEER, BE SUPPORTED BYTESTING OUTLINED IN SECTION 16, AND MUST BEAPPROVED BY COSTCO WHOLESALE. IN NO CASE WILLUSE OF SOIL CONTAINING MORE THAN FIVE (5) PERCENTORGANICS BY WEIGHT BE ALLOWED. IF EXISTING TOPSOILIS DEEMED SUITABLE FOR RE-USE, BY THE COSTCOWHOLESALE LANDSCAPE ARCHITECT, THE MATERIAL MAYBE STOCKPILED ONSITE IN A LOCATION APPROVED BYCOSTCO WHOLESALE.HATCH LEGENDHATCHDESCRIPTIONEXISTING FCSA ESMT OR WATER ANDSANITARY SEWER TO BE VACATED FRONT ROYAL PIKE - U.S. ROUTE 522LOT 1 GARBER ESTATE SUBDIVISION D.B. 838 PG. 1360 LANDS OF THE PRICE COMPANY D.B. 829 PG. 487 TM: 64-8-1 AREA: 13.002 AC. (R&M) OR 566,356 S.F. (M) ZONING: B2 N46°13'28"E 367.43'COSTEL L O D R I V E 3 4 - 1 3 6 7 ELODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLOD LODLODLODLODLODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011LOWLOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOD LOD LOD LOD LOD LOD LOD LOD LOD LOWLOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW LOW D SSD D D D D D D D C/OC/O C/O D D EEEEEEEEEE DD D D D D Alignment=Z-ALGN-ROAD-2 Station=10+42.59 L Offset=-1.29'CCCCCCCCPROP FUEL CANOPY WITH 32 FUELING POSITIONS HEIGHT = 19.5'CCCCCCCCPROP BUILDING EXPANSION FOOTPRINT AREA=20,709 SF FFE = 719.28 HEIGHT = 30.5'CCCCCCCCCCCCCCCCCC CCCC PROP 5' SIDEW A L K PROP 5' SIDEW A L KPROP 5' SIDEWALKPROP 5' SIDEWALK May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SITE-NJA220135.00-0A----->LAYOUT: C-301 OVERALL SITE PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-SITE PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-304 C-305 C-302 C-303 0 SCALE:1" = 50' 50 5012.525 C-301 OVERALL SITE PLAN C-306 FRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'S60°23'46"E (R) S63°10'47"E (M) 290.40' (R&M)N49°00'29"E (R)N46°13'28"E (M)159.00' (R&M)LIMITS OF DISTURBANCE = 12.85 AC LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011 98.9'LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW 20' FREDERICK WATER EASEMENT ENTRANCE 5 10+00 10+69. 9 2 10+50 10+00 10+69. 9 2 10+50 10+0 0 10 + 6 7 . 0 7 ENTRANCE 6 CCCC4 7 7 4 5 6 6 5 4 7 7 2 5 377 5 5'R 5'R 5'R 5'R 5'R 5'R 5'R 5'R 5'R 5'R 5'R5'R5'R5'R5'R 5'R 5'R15'R2 0 ' R 1 5 ' R 6'R 4.9'R 5'R10'10' 10' 10' 10' 24'10'20' 10' 10' 10'10' 10' 10' 10'10' 5'R5'R5'R5'R5'R 24'5'R 9'R 24'7'20'24'20'20'24'20'20'24'20'20'5'R 5'R 10' 10'24'20'24' 8'10'5'10'5'10'10' 6 7 CCCC7'7'1 10' (TYP) 15'25.2'9.3' 5' PROP CURB PROP CURB AND GUTTER CONCRETE PAD PROP LIGHT (TYP)PROP 5' SIDEWALK5' 1' R 2'R2'R1'R 1'R1'R 1' R 25'R14'PROP STOP SIGN PROP ACCESSIBLE RAMP 28.5'10+0 0 10 + 6 7 . 0 7 0 SCALE:1" = 20' 20 20510 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SITE-NJA220135.00-0A----->LAYOUT: C-302 SITE PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-SITE PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-302 SITE PLAN MATCHLINE - SHEET C-303 HATCH LEGEND: CONCRETE HEAVY-DUTY ASPHALT PAVEMENT ASPHALT PAVEMENT MILL AND OVERLAY LIMITS PER VDOT WP-2 FRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODCOSTELL O D R I V E 3 4 - 1 3 6 7 E R=50.00' (R&M) Δ=101°34'27" (R&M) L=88.64' (R&M) CHB=N01°46'45"W (R) CHB=N04°33'46"W (M) CHD=77.48' (R&M) W E SNORTH ZONEVCS NAD83 /2011LOWLOWLOW LOWLOWLOWTOTAL LIMITS OF DISTURBANCE = 12.85 AC LOD LOD LOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD PROP ROWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW VARIABLE STORM DRAINAGE EASEMENT VARIABLE STORM DRAINAGE EASEMENT ENTRANCE 4 10+0010+66.8110+5010+0010+66.8110+50CCCCCCCC4 75 6 4 2 4 5 5 3 3 7 7 8 7 9 9 10 9 8 7 7 3 2 10 9 6 10 1010 10 10 9 2 5'R5'R 5'R 5'R 5'R 5'R 5'R 5'R 5'R 5'R5'R 5'R 6'R 5'R3.1'R 5'R5 'R 5 'R 4.9'R 6.9'R 5'R 15 'R 5'R 5'R 5'R 5.9'R 7'R 5' R5'R5'R5' R 4.6'R5'R4.8'R 2.2'R 3.7'R 5' R 1. 5 ' R 1'R5'R5'R 5'R 5'R 35'R 10'10' 10' 10' 10' 10' 10' 10'20'20'10'10' 10' 10' 10' 10' 10' 10' 10' 10' 10'10'20'24'20'24'20'20'24'20'24'20'10' 10'20'4.8'20'10'10'4.8'20'20'5'R 5'R 5'R5'R5'R5'R 5'R 10'10' 24'7'20'24'20'20'24'20'24'7'20'24'20'20'24'20'5'R 10' 8'10'5'10'5'10'10' 5'R 5'R 10'24'CCCC7'7'PROP STOP SIGN 10' (TYP) 24' 14' 17' 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 3'R 14.1' 7.6' 17'19.5' 5'10' PROP 5' SIDE W A L K PROP ACCESSIBLE RAMP PROP LIGHT (TYP)5'PROP 5' SIDEWALK5' 37' 19.7' 17.3' PROP BOLLARD AND ADA SIGN (TYP) 2 2 PROP SIGHT DISTANCE EASEMENT 0 SCALE:1" = 20' 20 20510 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SITE-NJA220135.00-0A----->LAYOUT: C-303 SITE PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-SITE PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-303 SITE PLANMATCHLINE - SHEETC-304MATCHLINE - SHEET C-302 HATCH LEGEND: CONCRETE HEAVY-DUTY ASPHALT PAVEMENT ASPHALT PAVEMENT MILL AND OVERLAY LIMITS PER VDOT WP-2 N52°33'58" W ( R ) N 5 5 ° 2 0 ' 5 9 " W ( M ) 8 3 9 . 1 1 ' ( R & M ) COSTELL O D R I V E 3 4 - 1 3 6 7 E LOT 1 GARBER ESTATE SUBDIVISION D.B. 838 PG. 1360 LANDS OF THE PRICE COMPANY D.B. 829 PG. 487 TM: 64-8-1 AREA: 13.002 AC. (R&M) OR 566,356 S.F. (M) LOD LODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTOTAL LIMITS OF DISTURBANCE = 12.85 AC W E SNORTH ZONEVCS NAD83 /2011232.7'LOD LOD LOD PROP ROW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW D D C/O C/O C/O VARIABLE STORM DRAINAGE EASEMENT VARIABLE STORM DRAINAGE EASEMENT ENTRANCE 4 10+0010+66.8110+5010+0010+66.8110+504 4 2 4 3 2 5'R 5.9'R 5'R5' R PROP CROSSWALK (TYP)118.51'50.60' 4.6'R 15'R5'R2.2'R 5' R 3 5 'R35'R 5'R 10'30'5'20'24'20'24'20'4.8'20'10' 5'R 5'R 7'7'5' 8'10'5'10' 10' PROP STOP SIGN 3'R 3'R 3'R 3'R 14.1' 7.6' 5'10' 5' PROP ACCESSIBLE RAMP (TYP)21.5'4'5' CCCCCC 4 4 2 2 2 2 3 3 11 10 9 8 3 4 4 5 4 5 6 7 6 7 5 5 8 8 8 8 8 888 5'R 5'R 20'10'10'10'10'20'10' 10' 10' 10'20'10'10'10'10'10'10'10'10'10'10'10'10'10'10'24'24'20'20'24'20'20'24'20'20'20'24'24'24'20'20'7'10'10'20'20'8'10'10'5'10'10'10'10'CC CC CC 3'R 3'R 3'R 3'R 5' (TYP) 4'R 4'R 4'R 3'R 3'R 3'R 3'R 4.4'R 7.5'R 5'R 9.4'R 6.1'R 4.3'R 7.4'R 5'R 5 ' R CC 3 3 4 5'R5'R10'24'20'5'10'10' 5 ' R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 4'R 5.5'R 8.7'R 8.1'R 4'RPROP 5' SIDE W A L KPROP 5' SIDEWALKPROP ACCESSIBLE RAMP PROP LIGHT (TYP)5'4'37' 19.7' 17.3' PROP BOLLARD AND ADA SIGN (TYP) PROP BOLLARD AND ADA SIGN (TYP) 2 8'4'8'8' 10'20'10'10' 18 620'6'9.6' PROP FLUSH CURB 5.9'RPROP SIGHT DISTANCE EASEMENT PROP SIGHT DISTANCE EASEMENT 0 SCALE:1" = 20' 20 20510 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SITE-NJA220135.00-0A----->LAYOUT: C-304 SITE PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-SITE PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-304 SITE PLANMATCHLINE - SHEETC-303MATCHLINE - SHEETC-305HATCH LEGEND: CONCRETE HEAVY-DUTY ASPHALT PAVEMENT ASPHALT PAVEMENT MILL AND OVERLAY LIMITS PER VDOT WP-2 COST E L L O D R I V E 3 4 - 1 3 6 7 ES22°42'25"W (R) S19°55'24"W (M) 458.80' (R&M)LODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODR=460.00' (R&M) Δ=031°52'40" (R&M) L=255.93' (R&M) CHB=S68°30'18"E (R) CHB=N71°17'19"W (M) CHD=252.64' (R&M) R=1040.00' (R&M) Δ=008°18'13" (R&M) L=150.72' (R&M) CHB=N80°17'31"W (R) CHB=N83°04'32"W (M) CHD=150.59' (R&M) N84°26'38"W (R) N87°13'39"W (M) 129.72' (R&M) W E SNORTH ZONEVCS NAD83 /2011 PROP ROW PROP ROW LOWLOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW TOTAL LIMITS OF DISTURBANCE = 12.85 AC D PROP TRENCH DRAIN D D D D D C/O C/O C/O VARIABLE STORM DRAINAGE EASEMENT 20' STORM DRAINAGE EASEMENT D D PROP HYDRANT #2 EXTENT OF FREDERICK WATER COMBINED WATER AND SEWER EASEMENT. SEWER BEYOND THIS EASEMENT IS PRIVATELY OWNED AND MAINTAINED. D D D ENTRANCE 1 ENTRANCE 2 ENTRANCE 3 10+0010+70.4610+5010+0010+79.9210+ 5 0 10+0010+73.3210+5010+0010+70.4610+5010+0010+79.9210+ 5 0 10+0010+73.3210+50Alignment=Z-ALGN-ROAD-2 Station=10+42.59 L Offset=-1.29'CCCCCCCC10'24'40'24'40'24'40'24'20'10' 10' 10' 10'10'10'10'10' 10' 10' 10'40'40'40'20' 20' 24' 30' 36'24'24' 24'24'20' 7 9 97 7 7 7 8 8 9 9 3 8 9 4 4 5 20'3 10'R PROP STOP SIGN PROP RIGHT/LEFT-OUT RIGHT-IN ONLY SIGN 35 ' R 51' R 2'R 5'R PROPOSED PAVEMENT MARKINGS PROP CROSSWALK (TYP)118.51'50.60' PROP RETAINING WALL (DESIGNED BY OTHERS) (TYP)64'R100'R36' R 35'R5'R 12' (TYP)65' (TYP)10'30'5'20'24' PROP STOP SIGN 5'56'49'180'5' 5' 5'R 5 'R CC 8 6 7 8 8 20'10'10'10'10'20'10' 20'24'CC 4'R 4.4'R 7.5'R810' 4'R 4'R 4'R7 5 ' R 4'RPROP ACCESSIBLE RAMP PROP ACCESSIBLE RAMP 7.5'5.5' 10'R 5'R5'R5'R2'R5'R5' R5'R10'R5'R 5'R 5'R 5'R 5' R 5'R5'R6.5'R 5'R 5'R 200'R5'R5.1'R5'R10'R4.5'R 25'R5'R5' R 5' R 5' R4.5'R10'R5.4'R 3.1'R 6. 5 ' R6.5'R4'R 2.6'R 5'R 5'R 5'R 5'R 5'R 5'R 20 'R 5' R 10'30'R16'25'R18.19' 18.5'17.5' 4.8'R 6 PROP FLUSH CURB 5'R5'PROP ACCESSIBLE RAMP PROP ACCESSIBLE RAMP PROP SIGHT DISTANCE EASEMENT PROP SIGHT DISTANCE EASEMENT 0 SCALE:1" = 20' 20 20510 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SITE-NJA220135.00-0A----->LAYOUT: C-305 SITE PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-SITE PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-305 SITE PLAN MATCHLINE - SHEET C-306 MATCHLINE - SHEETC-304HATCH LEGEND: CONCRETE HEAVY-DUTY ASPHALT PAVEMENT ASPHALT PAVEMENT MILL AND OVERLAY LIMITS PER VDOT WP-2 LOT 1 GARBER ESTATE SUBDIVISION D.B. 838 PG. 1360 LANDS OF THE PRICE COMPANY D.B. 829 PG. 487 TM: 64-8-1 AREA: 13.002 AC. (R&M) OR 566,356 S.F. (M) ZONING: B2 S60°23'46"E (R) S63°10'47"E (M) 852.51' (R&M)S23°22'33"W (R)S20°35'32"W (M)82.25' (R&M)S22°42'25"W (R) S19°55'24"W (M) 458.80' (R&M)⅊TOTAL LIMITS OF DISTURBANCE = 12.85 AC LODLODLODLODLODLODLODLOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011 EX FDC (TO REMAIN)59.3'D SSPROP SHUTOFF VALVE PROP TRENCH DRAIN 20' FREDERICK WATER EASEMENT (TYP) 20' FREDERICK WATER EASEMENT PROP HYDRANT #1 D DD PROP OIL/WATER SEPARATOR PROP HYDRANT #3 (DEDICATED TO FDC) PROP SAND SEPARATOR D D 20' FREDERICK WATER EASEMENT CCFUEL ENTRY FUEL ENTRY 126.00' PROP "STOP" SIGN AND "DO NOT ENTER" SIGN (TYP) PROP VST GREEN MACHINE PROP BOLLARDS (TYP) PROP GAS ATTENDANT BUILDING PROP FUEL UNLOADING & DELIVERY AREA CC84.3' PROP UNDERGROUND STORAGE TANKS PROP STRIPING 24'40'10' 10'10' 10'40'20'PROP FUEL CANOPY WITH 32 FUELING POSITIONS HEIGHT = 19.5'92.50'20'20'9 97 7 8 9 7 244.00'48.26' 116.22'118.51'50.60' PROP RETAINING WALL (DESIGNED BY OTHERS) PROP BUILDING EXPANSION FOOTPRINT AREA=20,709 SF FFE = 719.28 HEIGHT = 30.5' PROP FOUR (4) BAYS PROP TRASH COMPACTORS T PROP TRANSFORMER 5'R5'R 65' (TYP)10' TYP20'41.67'24'10.119'100'35'13'12' 38.6' PROP ELECTRICAL ROOM PROP (7) - 7" RISERS, 11" TREAD PROP UNDERGROUND STORAGE TANKS 5' 7.5'5.5' 5'R 5'R 10'R1 0 ' R3'R1 5 ' R 10'R2 0 ' R10'R6.5'R 5'R 5'R 6.5'R3 5 ' R 60'R5'R5'R PROP MASONRY SCREENING WALL FOR TRASH COMPACTORS 20' FREDERICK WATER EASEMENT FOR FUTURE WATERMAIN EXTENSION (TYP) PROP TRANSFORMER PROP BATHROOM FOR ATTENDANT 59.2'0 SCALE:1" = 20' 20 20510 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SITE-NJA220135.00-0A----->LAYOUT: C-306 SITE PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-SITE PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-306 SITE PLAN HATCH LEGEND: CONCRETE HEAVY-DUTY ASPHALT PAVEMENT ASPHALT PAVEMENT MILL AND OVERLAY LIMITS PER VDOT WP-2 MATCHLINE - SHEET C-305 WB-67 - Interstate Semi-Trailer WB-67 - Interstate Semi-TrailerWB-67 - Interstate Semi-TrailerWB-50 - Intermediate Semi-TrailerWB-50 - Intermediate Semi-TrailerWB-67 - Interstate Semi-TrailerFRONT ROYAL PIKE - U.S. ROUTE 522LOT 1 GARBER ESTATE SUBDIVISION D.B. 838 PG. 1360 LANDS OF THE PRICE COMPANY D.B. 829 PG. 487 TM: 64-8-1 AREA: 13.002 AC. (R&M) OR 566,356 S.F. (M) ZONING: B2 N46°13'28"E 367.43'COSTEL L O D R I V E 3 4 - 1 3 6 7 ELODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLOD LODLODLODLODLODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011LOWLOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOD LOD LOD LOD LOD LOD LOD LOD LOD LOWLOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW LOW D D D D D D D D D D D EEEEEEEEEE DD D D D D 10+0010+70.4610+5010+0010+79.9210+ 5 0 10+0010+73.3210+5010+0010+66.8110+5010+00 10+69. 9 2 10+50 10+0010+70.4610+5010+0010+79.9210+ 5 0 10+0010+73.3210+5010+0010+66.8110+5010+00 10+69. 9 2 10+50 10+0 0 10 + 6 7 . 0 7 Alignment=Z-ALGN-ROAD-2 Station=10+42.59 L Offset=-1.29'CCCCCCCCPROP FUEL CANOPY WITH 32 FUELING POSITIONS HEIGHT = 19.5'CCCCCCCCPROP BUILDING EXPANSION FOOTPRINT AREA=20,709 SF FFE = 719.28 HEIGHT = 30.5'CCCCCCCC 5 'R CCCCCCCCCC CCCC PROP 5' SIDEW A L K PROP 5' SIDEW A L KPROP 5' SIDEWALK 20 'R 5' RPROP 5' SIDEWALK10+0 0 10 + 6 7 . 0 7 53 27.9 Max 68.5° Horiz Max 10° Vert 3 43.5 4 45.5 2.5 23.5 4 17.4 4.2 19.5 WB-67 - Interstate Semi-Trailer Overall Length 73.501ft Overall Width 8.500ft Overall Body Height 13.500ft Min Body Ground Clearance 1.334ft Max Track Width 8.500ft Lock-to-lock time 6.00s Max Steering Angle (Virtual)28.40° 42.5 19.92 Max 56° Horiz Max 10° Vert 3 33.5 4 35.5 2 15.5 3 10.4 4.2 12.5 WB-50 - Intermediate Semi-Trailer Overall Length 55.000ft Overall Width 8.500ft Overall Body Height 12.052ft Min Body Ground Clearance 1.334ft Max Track Width 8.500ft Lock-to-lock time 6.00s Max Steering Angle (Virtual)17.90° May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SITE-NJA220135.00-0A----->LAYOUT: C-307 OVERALL TRUCK TURN PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-SITE PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 0 SCALE:1" = 50' 50 5012.525 C-307 OVERALL TRUCK TURN PLAN © 202 5 Mi cr o s oft C or p or ati o n © 2 0 2 5 M a x ar © C N E S ( 2 0 2 5) Di stri b uti o n Air b u s D S N46°13'28"E 367.43'LODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLOD LOD LOD LOD LOD LODLODLOD LODLODLODLODLOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011LOWLOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOD LOD LOD LOD LOD LOD LOD LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW EEEEEEEEE ENTRANCE 1 ENTRANCE 2 ENTRANCE 3 ENTRANCE 4 ENTRANCE 5 Alignment=Z-ALGN-ROAD-2 Station=10+42.59 L Offset=-1.29' 346.4' 537.2' 554.5'410.1'ENTRANCE 6 5 'R PROP 5' SIDEWA L K PROP 5' SIDEW A L KPROP 5' SIDEWALK 20 'R 5' RPROP 5' SIDEWALK May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SITE-NJA220135.00-0A----->LAYOUT: C-308 OVERALL ENTRANCES PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-SITE PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 0 SCALE:1" = 60' 60 601530 C-308 ENTRANCE EXHIBIT LEGEND 200' RADIUS FROM PROPOSED AND EXISTING ENTRANCES DATUM ELEV 697.50 PROPOSED ENTRANCE 1 PROFILE (COSTELLO DRIVE) 700 705 710 700 705 710 9+50 10+00 10+50 11+00 11+50 PROP GRADE 10+45 PROPOSED ROW3.08%-3.17 % PARABOLIC CURVE (TYP) PVC 10+22 PVI 10+26 PVT 10+29 -1.36% DATUM ELEV 697.50 PROPOSED ENTRANCE 2 PROFILE (COSTELLO DRIVE) 700 705 710 700 705 710 9+50 10+00 10+50 11+00 11+50 PROP GRADE 5.52%10+50 PROPOSED ROW3.74% PVT 10+31 PVI 10+26 PVC 10+20 DATUM ELEV 702.50 EXISTING ENTRANCE 3 PROFILE (COSTELLO DRIVE) 705 710 715 705 710 715 9+50 10+00 10+50 11+0010+45 PROPOSED ROW2.70% 4.87% PROP GRADE 10+38 PROP 18" STM X-ING3.2' COVERPVC 10+33 PVI 10+35 PVT 10+36 DATUM ELEV 707.50 EXISTING ENTRANCE 4 PROFILE (COSTELLO DRIVE) 710 715 720 710 715 720 9+50 10+00 10+50 11+00 11+50 PROP GRADE 2.54% 2.75%10+42 PROPOSED ROW3.1' COVERPVC 10+27 PVI 10+28 PVT 10+29 10+44 PROP 18" STM X-INGDATUM ELEV 722.50 EXISTING ENTRANCE 5 PROFILE (FRONT ROYAL PIKE) 725 730 735 725 730 735 9+50 10+00 10+50 11+00 11+50 0.92%-1.94% PROP GRADE PVC 10+37 PVI 10+40 PVT 10+43 DATUM ELEV 722.50 EXISTING ENTRANCE 6 PROFILE (FRONT ROYAL PIKE) 725 730 735 725 730 735 9+50 10+00 10+50 11+00 -1.06% PROP GRADE May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SITE-NJA220135.00-0A----->LAYOUT: C-309 ENTRANCE PROFILESYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-SITE PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 0 SCALE:1" = 20' 20 20510 C-309 ENTRANCE PROFILES NOTE: CONTRACTOR TO CONSTRUCT ENTRANCE IN ACCORDANCE WITH VDOT CG-11 STANDARD DETAIL. CC CC CC CC PROPFUELCANOPYWITH 32FUELINGPOSITIONSHEIGHT= 19.5'CCCCCCCC PROP BUILDING EXPANSIONFOOTPRINT AREA=20,709 SFFFE = 719.28HEIGHT = 30.5'CCCCCCCC CCCCCCCCCCCCCCPROP 5' SIDEWALKPROP 5' SIDEWALKPROP 5' SIDEW A L K PROP 5' SIDEWALK EE E E E E E E E E FRONT ROYAL PIKE - U.S. ROUTE 522 LOT 1GARBER ESTATE SUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)ZONING: B2N46°13'28"E 367.43'COSTELLO DRIVE 34-1367ELOD LODLOD LOD LOD LOD LODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODWESNORTH ZONEVCS NAD83/2011LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLODLODLODLODLODLODLODLODLODLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWPROP 300' HOSE LAY PROP 300' HOSE LAYPROP 300' HOSE LAYPROP 300' HOSE LAY PROP 300' HOSE LAYPROP 300' HOSE LAYPROP 300' HOSE LAY 0SCALE:1" = 50'505012.525C-310OVERALL FIREMARSHALPLAN May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-FIRE-NJA220135.00-0A----->LAYOUT: C-310 FIRE MARSHAL PLANYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-FIREPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026LEGENDPROP FIRE LANE MARKINGPROP FIRE LANE SIGNPROP FIRE LANE SIGN LABELXEX FIRE LANE SIGNEX FIRE LANE SIGN LABELXC-311C-312 CCCC CCCC CC CC CC CC CCCCCCPROP 5' SIDEWALKPROP 5' SIDEWALKPROP 5' SIDEW A L K PROPLIGHT(TYP)PROPLIGHT(TYP)PROPLIGHT(TYP)PROP 5' SIDEWALK VARIABLE STORMDRAINAGE EASEMENTVARIABLE STORMDRAINAGE EASEMENTVARIABLE STORMDRAINAGE EASEMENT20'FREDERICKWATEREASEMENTFRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'S60°23'46"E (R) S63°10'47"E (M) 290.40' (R&M)N52°33'58"W (R) N55°20'59"W (M) 839.11' (R&M)N49 ° 0 0 ' 2 9 " E ( R ) N46 ° 1 3 ' 2 8 " E ( M ) 159. 0 0 ' ( R & M )COSTELLO DRIVE 34-1367ELIMITS OF DISTURBANCE = 12.85 ACLOD LOD LODLODLOD LOD LOD LOD LOD LODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTOTAL LIMITS OF DISTURBANCE = 12.85 ACCOSTELLO DRIVE 34-1367ER=50.00' (R&M)Δ=101°34'27" (R&M)L=88.64' (R&M)CHB=N01°46'45"W (R)CHB=N04°33'46"W (M)CHD=77.48' (R&M)WESNORTH ZONEVCS NAD83/2011WESNORTH ZONEVCS NAD83/2011WESNORTH ZONEVCS NAD83/2011232.7'98.9'LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWTOTAL LIMITS OF DISTURBANCE = 12.85 ACLODLODLODLODLODLODLODLODLODLODLODLODLO DPROP ROWPROP ROWLOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOWLOW LOWLOWEXISTING FIRE HYDRANTEXISTING FIRE HYDRANTPROP 300' HOSE LAYPROP 300' HOSE LAY PROP 300' HOSE LAYCDDCAACDADDDDCDCACA0SCALE:1" = 40'40401020C-311FIRE MARSHALPLAN May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-FIRE-NJA220135.00-0A----->LAYOUT: C-311 FIRE MARSHAL PLANYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-FIREPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026LEGENDPROP FIRE LANE MARKINGPROP FIRE LANE SIGNPROP FIRE LANE SIGN LABELXEX FIRE LANE SIGNEX FIRE LANE SIGN LABELXMATCHLINE - SHEET C-311 CC CC FUELENTRYFUELENTRYPROP GASATTENDANTBUILDINGCC CC 84.3'PROP FUEL CANOPYWITH 32 FUELINGPOSITIONSHEIGHT = 19.5'PROP BUILDING EXPANSIONFOOTPRINT AREA=20,709 SFFFE = 719.28HEIGHT = 30.5'PROP FOUR (4) BAYSCCCCCCCCCCCCPROP 5' SIDEWALKPROPACCESSIBLERAMPPROPACCESSIBLERAMPPROP MASONRYSCREENING WALLFOR TRASHCOMPACTORS20' FREDERICK WATER EASEMENT FOR FUTUREWATERMAIN EXTENSION (TYP)PROP FLUSH CURBPROPBATHROOMFORATTENDANTPROPACCESSIBLERAMPPROPACCESSIBLERAMP59.2'VARIABLE STORMDRAINAGE EASEMENTVARIABLE STORMDRAINAGE EASEMENT20' STORMDRAINAGE EASEMENT20' FREDERICK WATER EASEMENT (TYP)20' FREDERICKWATEREASEMENTEE E E E E E E EE E E E E EEXTENT OF FREDERICKWATER COMBINED WATERAND SEWER EASEMENT.SEWER BEYOND THISEASEMENT IS PRIVATELYOWNED AND MAINTAINED.20' FREDERICKWATEREASEMENTLOT 1GARBER ESTATE SUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)ZONING: B2COSTELLO DR IVE 34 -1367ES60°23'46"E (R) S63°10'47"E (M) 852.51' (R&M)S23°22'33"W (R)S20°35'32"W (M)82.25' (R&M)S22°42'25"W (R) S19°55'24"W (M) 458.80' (R&M)N52°33'58"W (R) N55°20'59"W (M) 839.11' (R&M)COSTELLO DRIVE 34-1367ELOT 1GARBER ESTATESUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)TOTAL LIMITS OF DISTURBANCE = 12.85 ACLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTOTAL LIMITS OF DISTURBANCE = 12.85 ACR=460.00' (R&M)Δ=031°52'40" (R&M)L=255.93' (R&M)CHB=S68°30'18"E (R)CHB=N71°17'19"W (M)CHD=252.64' (R&M)R=1040.00' (R&M)Δ=008°18'13" (R&M)L=150.72' (R&M)CHB=N80°17'31"W (R)CHB=N83°04'32"W (M)CHD=150.59' (R&M)N84°26'38"W (R)N87°13'39"W (M)129.72' (R&M)EWESNORTH ZONEVCS NAD83/2011WESNORTH ZONEVCS NAD83/2011EX FDC(TO REMAIN)59.3'WATER (TBR)TELEPHONE (TBR)PROP ROWPROP ROWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWTOTAL LIMITS OFDISTURBANCE = 12.85 ACLOWLOWLOWLOWLOWLOWPROP 300' HOSE LAY PROP 300' HOSE LAYPROP 300' HOSE LAYPROP 300' HOSE LAYPROP 300' HOSE LAYPROP 300' HOSE LAY DADDDDPROP FIRE HYDRANTPROP FIRE HYDRANTADDDDDDDDCACACACADCDDADCCACAAPROP FIRE HYDRANT(DEDICATED TO FDC)DCCA0SCALE:1" = 40'40401020C-312FIRE MARSHALPLAN May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-FIRE-NJA220135.00-0A----->LAYOUT: C-312 FIRE MARSHAL PLANYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-FIREPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026LEGENDPROP FIRE LANE MARKINGPROP FIRE LANE SIGNPROP FIRE LANE SIGN LABELXEX FIRE LANE SIGNEX FIRE LANE SIGN LABELXMATCHLINE - SHEET C-310 FIRE MARSHAL NOTES:1.FIRE HYDRANT #3 TO BE DEDICATED TO FDC INACCORDANCE WITH FREDERICK COUNTY CODE,CHAPTER 90, SECTION 90-4 E(2). FRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'COSTELL O D R I V E 3 4 - 1 3 6 7 ELODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLOD LODLODLODLODLODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011LOWLOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOD LOD LOD LOD LOD LOD LOD LOD LOD LOWLOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW LOWFRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'COSTELL O D R I V E 3 4 - 1 3 6 7 ELODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLOD LODLODLODLODLODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011LOWLOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOD LOD LOD LOD LOD LOD LOD LOD LOD LOWLOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW LOW PROP 5' SIDEW A L K PROP 5' SIDEW A L KPROP 5' SIDEWALKPROP 5' SIDEWALKPROP 5' SIDEW A L K PROP 5' SIDEW A L KPROP 5' SIDEWALKPROP 5' SIDEWALKD WWWWWWWWWWWSSD D D D D D D D SL SSSSSSD D EEEEEEEEEE DD D D D D721716 719 719 720717718719720721722723718 715716 71071271371 6 7 1 7 71771871972072172272372 4 718719720721722723724720721722723718718718 717718715716717718719720721722 718719720 719 715 716 717 715 716 716 717 717 718 718 714 715 715716 716718 719 718 7217227187197207 2 1 7 2 2 723716 7177 1 8 717 716 713 704705 706 707 708 709 710 71171271371471 4 714715715715716717718 715715716716716716717716 717718 719703704705706707708709713714714714715714 716716 710 711 712 713 714 715 716 710713714715716716718 719 720 717 718 716 707 708 709710711712713714 715 716717719719718 719 717 71671471571571671771972572572572672570 0 701 70 2 70 3 704 705 704704703 703 1"=50' 0 5012.52550 C-402 C-403 C-406 C-404 C-405 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-GRAD-NJA220135.00-0A----->LAYOUT: C-401 - OVERALL GRADING PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-GRAD PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-401 OVERALL GRADING PLAN INS E T 1 - S E E C - 4 0  INSET 2 - SEE C-40 INSET 3 - SEE C-40 INSET 4 - SEE C-40 FRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'S60°23'46"E (R) S63°10'47"E (M) 290.40' (R&M)N49°00'29"E (R)N46°13'28"E (M)159.00' (R&M)PROP. SAWCUT LIMITS OF DISTURBANCE = 12.85 AC LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLOD LODLODLODLODPROP. SAWCUT W E SNORTH ZONEVCS NAD83 /2011 W 98.9'LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW PROP. SAWCUT FRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'S60°23'46"E (R) S63°10'47"E (M) 290.40' (R&M)N49°00'29"E (R)N46°13'28"E (M)159.00' (R&M)PROP. SAWCUT LIMITS OF DISTURBANCE = 12.85 AC LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLOD LODLODLODLODPROP. SAWCUT W E SNORTH ZONEVCS NAD83 /2011 W 98.9'LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW PROP. SAWCUT PROP CURB PROP CURB AND GUTTER CONCRETE PAD PROP 5' SIDEWALKPROP CURB PROP CURB AND GUTTER CONCRETE PAD PROP 5' SIDEWALKRI D G E RIDGE RIDGE RIDGE RID G E PROP 18" RCPPROP 24" RCP PROP 8" HDPE PROP 8" HDPE PROP 8" HDPE PROP 8" HDPE PROP 8" HDPE 71 8 TP TP TP TPTPTP 20' FREDERICK WATER EASEMENT SEE SHEET C-701 FOR DETAIL GRADING OF THE FRONT ROYAL PIKE TURN LANE TC 722.47 BC 721.97 TC 721.93 BC 721.43 TC 721.42 BC 720.92 TC 720.94 BC 720.44 TC 720.59 BC 720.09 TC 720.74 BC 720.24 TC 720.01 BC 719.51 TC 720.01 BC 719.51 HP|TC 719.93 TC 720.80 BC 720.30 TC 720.39 BC 719.89 TC 722.50 BC 722.00 TC 722.05 BC 721.55 TC 719.18 BC 718.68 TC 719.16 BC 718.66 TC 721.10 BC 720.60 TC 720.69 BC 720.19 TC 720.32 BC 719.82 TC 719.91 BC 719.41 TC 718.08 BC 717.58 TC 718.08 BC 717.58 TC 717.66 BC 717.16 TC 717.74 BC 717.24 TC 717.82 BC 717.32 TC 717.92 BC 717.42 TC 717.86 BC 717.36 TC 717.93 BC 717.43 TC 718.38 BC 717.88 TC 720.12 BC 719.62 TC 719.97 BC 719.47 TC 719.81 BC 719.31 TC 719.41 BC 718.91 TC 719.83 BC 719.33 TC 719.68 BC 719.18 TC 719.51 BC 719.01 TC 719.00 BC 718.50 TC 718.94 BC 718.44 TC 719.02 BC 718.52 TC 719.00 BC 718.50 TC 718.86 BC 718.36 TC 719.21 BC 718.71 TC 718.93 BC 718.43 TC 721.28 BC 720.78 TC 721.58 BC 721.08 TC 719.58 BC 719.08 TC 719.31 BC 718.81 TC 719.18 BC 718.68 TC 719.36 BC 718.86 TC 719.75 BC 719.25 TC 720.35 BC 719.85 TC 720.21 BC 719.71 TC 720.06 BC 719.56 TC 721.83 BC 721.33 TC 721.61 BC 721.11 TC 721.85 BC 721.35 TC 722.18 BC 721.68 TC 722.82 BC 722.32 TC 722.37 BC 721.87 TC 723.66 BC 723.16 TC 723.96 BC 723.46 TC 723.82 BC 723.32 TC 724.09 BC 723.59 TC 723.13 BC 722.63 TC 723.44 BC 722.94 TC 718.80 BC 718.30 TC 718.80 BC 718.30 HP|TC 719.26 TC 719.10 BC 718.60 HP|TC 721.45 TC 721.65 BC 721.15 TC 723.74 BC 723.24 TC 723.35 BC 722.85 TC 721.95 BC 721.45 TC 724.33 BC 723.83 HP|TC 725.21 TC 723.68 BC 723.18 TC 724.24 BC 723.74 TC 723.88 BC 723.38 TC 719.10 BC 718.60 TC 719.10 BC 718.60 TC 719.42 BC 718.92 TC 718.94 BC 718.44 TC 719.41 BC 718.91 TC 723.74 BC 723.24 TC 724.08 BC 723.58 TC 724.78 BC 724.28 TC 724.80 BC 724.30 TC 724.85 BC 724.35 ME|BC 724.33 TC 724.47 BC 723.97 ME|G 724.36 ME|G 723.98 TC 724.97 BC 724.47 TC 724.67 BC 724.17 TC 724.59 BC 724.09 TC 724.53 BC 724.03 TC 724.53 BC 724.03 TC 724.53 BC 724.03 TC 724.83 BC 724.33 TC 724.61 BC 724.11 TC 718.95 BC 718.45 TC 718.57 BC 718.07 ME|G 718.97 ME|G 718.97 TC 720.95 BC 720.45 TC 718.91 BC 718.41 TC 718.87 BC 718.37 TC 718.94 BC 718.44 ME|G 719.21 ME|G 718.95 G 718.09 G 718.20 G 717.85 G 718.17 G 718.24 G 718.32 G 718.10 G 718.27 G 718.34 G 717.94 G 717.95 G 718.43 G 718.30 G 718.23 G 718.21 G 718.47 G 718.29 G 718.21G 718.01 ME|TC 722.06 ± ME|G 722.07± CO-2 BLDG-B CO-3 CO-4 BLDG-D BLDG-C BLDG-E A-140 A-150 721719 719 72072172272372 4 718719720721722723724719 718 725725725726725G 718.35 G 717.44 G 724.85 G 725.61 G 725.69 G 725.76 G 725.70 G 725.51 G 725.53 G 725.69 G 725.79 G 725.26 G 725.36 1"=20' 0 2051020 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-GRAD-NJA220135.00-0A----->LAYOUT: C-402 - GRADING PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-GRAD PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-402 GRADING PLAN MATCHLINE - SHEET C-403 NOTES: 1.COSTCO WILL NEED TO COORDINATE THE RELOCATION OF THE TELEPHONE LINE. 2.SEE STORM PROFILE SHEETS C-605 - C-616 FOR PROPOSED INVERTS AND RIM ELEVATIONS. 3.CONTRACTOR TO ADJUST SANITARY RIM ELEVATIONS PER RIM SPOT ELEVATION SHOWN. 4.OVERLAND RELIEF PATH OUTFALLS TO COSTELLO DRIVE. 5.ALL GRATE INLETS IN AREAS ACCESSIBLE TO THE PUBLIC WILL REQUIRED AN APPROPRIATELY SIZED GRATE OPENING. FRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'PROP. SAWCUT LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP. SAWCUT PROP. SAWCUT PROP. SAWCUT COSTELL O D R I V E 3 4 - 1 3 6 7 E R=50.00' (R&M) Δ=101°34'27" (R&M) L=88.64' (R&M) CHB=N01°46'45"W (R) CHB=N04°33'46"W (M) CHD=77.48' (R&M)232.7'PROP. SAWCUT LOWLOWLOW LOWLOWLOWTOTAL LIMITS OF DISTURBANCE = 12.85 AC LOD LOD LOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD PROP ROW PROP ROWLOWLOWLOWLOWLOWLOWLOWLOWLOWPROP. SAWCUT PROP. SAWCUT FRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'PROP. SAWCUT LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP. SAWCUT PROP. SAWCUT PROP. SAWCUT COSTELL O D R I V E 3 4 - 1 3 6 7 E R=50.00' (R&M) Δ=101°34'27" (R&M) L=88.64' (R&M) CHB=N01°46'45"W (R) CHB=N04°33'46"W (M) CHD=77.48' (R&M)232.7'PROP. SAWCUT LOWLOWLOW LOWLOWLOWTOTAL LIMITS OF DISTURBANCE = 12.85 AC LOD LOD LOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD PROP ROW PROP ROWLOWLOWLOWLOWLOWLOWLOWLOWLOWPROP. SAWCUT PROP. SAWCUT PROP 5' SIDE W A L K PROP 5' SIDEWALKPROP 5' SIDEWALKPROP SIGHT DISTANCE EASEMENT PROP 5' SIDE W A L K PROP 5' SIDEWALKPROP 5' SIDEWALKPROP SIGHT DISTANCE EASEMENT RIDGE RI D G E RIDGE RID G E PROP 24" RCP PROP 15" RCP PROP 24" RCPPROP 30" RCP PROP 12" HDPE PROP 15" RCP PROP 15" RCPPROP 12" HDPEPROP 18" RCP PROP 18" RCP PROP 8" HDPE PROP 8" HDPE PROP 8" HDPEPROP 8" HDPE PROP 8" HDPEP R O P 8 " H D P E TP TP TP TPPROP 15" RCP W E SNAD83 NAD83TC 720.01 BC 719.51 TC 720.39 BC 719.89 TC 722.05 BC 721.55 TC 719.16 BC 718.66 TC 720.69 BC 720.19 TC 719.91 BC 719.41 TC 718.08 BC 717.58 TC 717.74 BC 717.24 TC 717.86 BC 717.36 TC 717.93 BC 717.43 TC 720.12 BC 719.62 TC 719.97 BC 719.47 TC 719.81 BC 719.31 TC 719.62 BC 719.12 TC 719.22 BC 718.72 TC 719.41 BC 718.91 TC 719.83 BC 719.33 TC 719.68 BC 719.18 TC 719.51 BC 719.01 TC 719.32 BC 718.82 TC 719.00 BC 718.50 TC 718.94 BC 718.44 TC 719.02 BC 718.52 TC 718.84 BC 718.34 TC 719.00 BC 718.50 TC 718.86 BC 718.36 TC 719.21 BC 718.71 TC 718.93 BC 718.43 TC 721.28 BC 720.78 TC 721.58 BC 721.08 TC 719.58 BC 719.08 TC 719.31 BC 718.81 TC 719.18 BC 718.68 TC 719.36 BC 718.86 TC 719.75 BC 719.25 TC 720.35 BC 719.85 TC 720.21 BC 719.71 TC 720.06 BC 719.56 TC 719.92 BC 719.42 TC 721.83 BC 721.33 TC 721.40 BC 720.90 TC 721.61 BC 721.11 TC 721.10 BC 720.60 TC 721.85 BC 721.35 TC 722.18 BC 721.68 TC 722.37 BC 721.87 TC 723.68 BC 723.18 TC 724.24 BC 723.74 TC 723.88 BC 723.38 TC 723.73 BC 723.23 TC 723.74 BC 723.24 TC 723.81 BC 723.31 TC 718.82 BC 718.32 TC 718.82 BC 718.32 TC 718.84 BC 718.34 TC 718.72 BC 718.22 TC 720.39 BC 719.89 TC 720.71 BC 720.21 TC 720.57 BC 720.07 TC 720.90 BC 720.40 TC 720.77 BC 720.27 TC 721.11 BC 720.61 TC 721.01 BC 720.51 TC 721.31 BC 720.81 TC 718.76 BC 718.26 TC 718.91 BC 718.41 TC 718.65 BC 718.15 TC 718.63 BC 718.13 TC 723.74 BC 723.24 TC 724.08 BC 723.58 TC 724.80 BC 724.30 TC 724.85 BC 724.35 ME|BC 724.33 TC 724.08 BC 723.58 TC 724.47 BC 723.97 ME|G 724.36 ME|G 723.68 ME|G 723.53 ME|G 723.98 TC 718.89 BC 718.39 TC 718.79 BC 718.29TC 719.09 BC 718.59 TC 719.16 BC 718.66 TC 719.34 BC 718.84 TC 718.33 BC 717.83 TC 718.55 BC 718.05 TC 718.81 BC 718.31 TC 718.67 BC 718.17 TC 717.08 BC 716.58 TC 720.74 BC 720.24 HP|TC 717.53HP|TC 719.24 TC 717.00 BC 716.50 TC 716.85 BC 716.35TC 720.40 BC 719.90 TC 720.62 BC 720.12 TC 721.09 BC 720.59 TC 720.86 BC 720.36 TC 722.43 BC 721.93 TC 722.53 BC 722.03 TC 723.19 BC 722.69 TC 723.28 BC 722.78 TC 723.02 BC 722.52 TC 723.80 BC 723.30 TC 722.98 BC 722.48 TC 723.22 BC 722.72 TC 723.37 BC 722.87 HP|TC 723.67 TC 723.48 BC 722.98 TC 723.08 BC 722.58 TC 722.48 BC 721.98 TC 722.41 BC 721.91 TC 722.26 BC 721.76 TC 722.03 BC 721.53 TC 719.97 BC 719.47 TC 718.11 BC 717.61 TC 720.08 BC 719.58 TC 721.62 BC 721.12 TC 721.60 BC 721.10 TC 721.25 BC 720.75 ME|G 723.13 ME|G 721.71 ME|G 721.36 ME|BC 721.06 TC 718.78 BC 718.28 TC 717.19 BC 716.69 TC 718.19 BC 717.69 TC 717.32 BC 716.82 TC 716.77 BC 716.27 TC 717.30 BC 716.80 TC 717.89 BC 717.39 TC 718.13 BC 717.63 TC 718.27 BC 717.77 TC 718.42 BC 717.92 TC 718.28 BC 717.78 TC 718.17 BC 717.67 TC 717.97 BC 717.47 TC 717.79 BC 717.29 TC 717.60 BC 717.10 TC 717.42 BC 716.92 TC 717.52 BC 717.02 TC 717.70 BC 717.20 TC 717.90 BC 717.40 TC 718.08 BC 717.58 TC 718.09 BC 717.59 TC 718.19 BC 717.69 TC 718.91 BC 718.41 TC 719.82 BC 719.32 TC 719.86 BC 719.36 TC 717.89 BC 717.39 TC 717.97 BC 717.47 TC 716.93 BC 716.43 TC 717.41 BC 716.91 TC 717.41 BC 716.91 TC 719.08 BC 718.58 TC 719.08 BC 718.58 TC 715.87 BC 715.37 TC 716.00 BC 715.50 TC 716.41 BC 715.91 TC 718.94 BC 718.44 ME|G 718.95 ME|G 718.92 G 717.79 G 718.09 G 718.20 G 717.85 G 718.19G 718.07G 717.97G 717.87 G 718.17 G 718.24 G 718.32 G 718.10 G 718.27 G 718.34 G 717.94 TC 719.01 BC 718.51 TC 717.28 BC 716.78 TC 717.63 BC 717.13 TC 718.13 BC 717.63 TC 718.14 BC 717.64 TC=BC 717.74 TC 718.78 BC 718.28 TC 718.32 BC 717.82 G 717.49 G 717.65 G 717.88 G 717.73 G 717.96 G 718.11 TC 718.74 BC 718.24 TC 718.94 BC 718.44 HP|TC 719.06 TC 718.03 BC 717.53 TC 717.83 BC 717.33 TC 717.86 BC 717.36 G 717.91 G 716.82 G 717.02 TC 716.94 BC 716.44 TC 716.21 BC 715.71 TC 716.52 BC 716.02 TC 716.64 BC 716.14 TC 717.21 BC 716.71 TC 718.81 BC 718.31 TC 718.82 BC 718.32 TC=BC 718.10 TC=BC 717.96 TC 718.66 BC 718.16 TC 718.75 BC 718.25 TC=BC 718.22 TC 718.87 BC 718.37 TC 718.60 BC 718.10 G 716.98G 716.79 G 718.43 G 718.29 G 718.21G 718.01 ME|G 714.75 ME|G 715.65 CO-4 BLDG-D CO-5 BLDG-E CO-6 CO-7 F-110 A-133 A-132 A-121 A-131 A-130 A-120 D-170 D-160 D-150 A-122 717718719720721722723718 71 6 7 1 7 71771871972072172272372 4 718720721722723718717 718 7217227187197207 2 1 7 2 2 723716 7177 1 8 716725725G 724.94 G 719.01 LP 717.73 LP 716.16 LP 715.92 G 715.74G 717.19 G 715.68 G 717.51 G 718.78 G 721.62 G 725.61 G 725.69 G 725.76 G 725.26 G 725.36 G 725.37 G 725.45 G 725.20 G 725.28 G 720.63 G 720.53 G 718.66 G 718.56 G 716.88 G 716.78 G 717.13 G 716.90 G 722.28 G 722.19 G 717.14 G 717.21 1"=20' 0 2051020 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-GRAD-NJA220135.00-0A----->LAYOUT: C-403 - GRADING PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-GRAD PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-403 GRADING PLANMATCHLINE - SHEETC-404MATCHLINE - SHEET C-402 NOTES: 1.COSTCO WILL NEED TO COORDINATE THE RELOCATION OF THE TELEPHONE LINE. 2.SEE STORM PROFILE SHEETS C-605 - C-616 FOR PROPOSED INVERTS AND RIM ELEVATIONS. 3.CONTRACTOR TO ADJUST SANITARY RIM ELEVATIONS PER RIM SPOT ELEVATION SHOWN. 4.OVERLAND RELIEF PATH OUTFALLS TO COSTELLO DRIVE. 5.ALL GRATE INLETS IN AREAS ACCESSIBLE TO THE PUBLIC WILL REQUIRED AN APPROPRIATELY SIZED GRATE OPENING. N52°33'58" W ( R ) N 5 5 ° 2 0 ' 5 9 " W ( M ) 8 3 9 . 1 1 ' ( R & M ) COSTEL L O D R I V E 3 4 - 1 3 6 7 E PROP. SAWCUT LOD LODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTOTAL LIMITS OF DISTURBANCE = 12.85 AC PROP. SAWCUT PROP. SAWCUT W E SNORTH ZONEVCS NAD83 /2011232.7'PROP. SAWCUT LOD LOD LOD PROP ROW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW N52°33'58" W ( R ) N 5 5 ° 2 0 ' 5 9 " W ( M ) 8 3 9 . 1 1 ' ( R & M ) COSTEL L O D R I V E 3 4 - 1 3 6 7 E PROP. SAWCUT LOD LODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTOTAL LIMITS OF DISTURBANCE = 12.85 AC PROP. SAWCUT PROP. SAWCUT W E SNORTH ZONEVCS NAD83 /2011232.7'PROP. SAWCUT LOD LOD LOD PROP ROW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW PROP 5' SIDE W A L KPROP 5' SIDEWALKPROP FLUSH CURB PROP 5' SIDE W A L KPROP 5' SIDEWALKPROP FLUSH CURB RIDGERIDGERIDGERIDGE RIDGERIDGERIDGERIDGERIDGERIDGERIDGERIDGERIDGERIDGE PROP 24" RCP PROP 24" RCPPROP 30" RCP PROP 30" RCP PROP 15" RC P PROP 18" RC P PROP 24" RCP PROP 24" RCPPROP 18" RCP PROP 18" R C P PROP 18" RC P PROP 18" RCP PROP 8" HDPE PROP 8" HDPE PROP 8" HDPEPROP 8" HDPE PROP 8" HDPEP R O P 8 " H D P E PROP 8" HDPE PROP 8" HDPE PROP 8" HDPE PROP 8" HDPE PROP 8" HDPE PROP UNDG SWM SYSTEM #1 ADS STORMTECH CHAMBER SYSTEM STORAGE VOLUME = 32,414 CF STONE BASE = 704.00' BOTTOM OF CHAMBERS = 704.75' TOP OF SYSTEM = 710.95' D D SLSLC/O C/O C/O TP TP TC 719.16 BC 718.66 TC 719.02 BC 718.52 TC 718.84 BC 718.34 TC 719.00 BC 718.50 TC 718.86 BC 718.36 TC 719.21 BC 718.71 TC 718.93 BC 718.43 TC 718.84 BC 718.34 TC 718.72 BC 718.22 TC 717.32 BC 716.82 TC 716.77 BC 716.27 TC 717.30 BC 716.80 TC 717.89 BC 717.39 TC 718.13 BC 717.63 TC 718.27 BC 717.77 TC 718.42 BC 717.92 TC 718.28 BC 717.78 TC 718.17 BC 717.67 TC 715.87 BC 715.37 TC 716.00 BC 715.50 TC 716.41 BC 715.91 TC 718.94 BC 718.44 ME|G 718.95 ME|G 718.92 G 718.19G 718.07G 717.97 G 718.24 G 718.32 G 718.10 G 718.27 G 718.34 TC 717.28 BC 716.78 TC 717.63 BC 717.13 TC 718.13 BC 717.63 TC 718.14 BC 717.64 TC=BC 717.74 TC 716.33 BC 715.83 TC 715.93 BC 715.43 TC 716.59 BC 716.09 HP|TC 716.77 TC 716.55 BC 716.05 TC 716.32 BC 715.82 TC 716.33 BC 715.83 TC 716.62 BC 716.12 TC 716.46 BC 715.96 TC 716.61 BC 716.11 TC 716.89 BC 716.39 TC 716.65 BC 716.15 HP|TC 716.46 TC 716.46 BC 715.96 TC 716.46 BC 715.96 TC 716.57 BC 716.07 TC 716.73 BC 716.23 TC 716.57 BC 716.07 HP|TC 716.56 TC 716.33 BC 715.83 TC 716.33 BC 715.83 TC 716.60 BC 716.10 HP|TC 716.77 TC 716.60 BC 716.10 HP|TC 716.60 TC 716.36 BC 715.86 TC 716.36 BC 715.86 TC 716.20 BC 715.70 TC 716.44 BC 715.94 TC 716.68 BC 716.18 HP|TC 716.14 TC 716.44 BC 715.94 TC 715.96 BC 715.46 HP|TC 718.57TC 718.09 BC 717.59 TC 718.09 BC 717.59 TC 718.09 BC 717.59 TC 718.21 BC 717.71 HP|TC 718.44 TC 718.21 BC 717.71 TC 717.97 BC 717.47 TC 717.97 BC 717.47 TC 717.97 BC 717.47 TC 718.21 BC 717.71 HP|TC 718.53 TC 718.21 BC 717.71 TC 718.06 BC 717.56 TC 717.97 BC 717.47 TC 717.97 BC 717.47 G 717.78G 717.98G 717.75 G 717.50 G 717.43 G 717.23G 717.34 G 717.39 G 717.62 G 717.86 G 718.18 TC 718.70 BC 718.20 TC 718.89 BC 718.39 HP|TC 718.91 TC 718.32 BC 717.82 G 717.49 G 717.65 G 717.88 G 717.73 G 717.96 G 718.11 TC 718.74 BC 718.24 TC 718.94 BC 718.44 HP|TC 719.06 TC 718.90 BC 718.40 TC 719.08 BC 718.58 TC 718.33 BC 717.83 TC 718.33 BC 717.83 TC 718.75 BC 718.25 HP|TC 718.86 TC 718.84 BC 718.34 TC 718.69 BC 718.19 TC 718.70 BC 718.20 TC 718.68 BC 718.18 TC 718.69 BC 718.19TC 718.93 BC 718.43 TC 717.37 BC 716.87 TC 717.37 BC 716.87 TC 717.13 BC 716.63 TC 717.13 BC 716.63 TC 718.03 BC 717.53 TC 717.83 BC 717.33 TC 717.86 BC 717.36 G 717.91 G 716.82 G 717.02 TC 716.94 BC 716.44 TC 715.76 BC 715.26 TC 716.06 BC 715.56 HP|TC 716.02 HP|TC 716.06 TC 715.70 BC 715.20 TC 716.21 BC 715.71 TC 716.52 BC 716.02 TC 716.64 BC 716.14 TC 717.21 BC 716.71 TC 717.15 BC 716.65 TC 717.43 BC 716.93 TC 717.69 BC 717.19 TC 717.56 BC 717.06 TC 717.56 BC 717.06 TC 717.36 BC 716.86 TC 717.56 BC 717.06 TC 717.49 BC 716.99 TC 717.41 BC 716.91 TC 717.73 BC 717.23 TC 717.97 BC 717.47 TC 714.75 BC 714.25 TC 714.98 BC 714.48 TC 715.16 BC 714.66 HP|TC 715.13 TC 715.00 BC 714.50 TC 714.91 BC 714.41 TC 715.15 BC 714.65 TC 715.09 BC 714.59 TC 715.05 BC 714.55 TC 715.05 BC 714.55 TC 716.88 BC 716.38 TC 716.15 BC 715.65 TC 715.48 BC 714.98 TC 715.96 BC 715.46 TC 715.89 BC 715.39 TC 715.69 BC 715.19 TC 715.86 BC 715.36 TC 715.92 BC 715.42 TC 715.43 BC 714.93 TC 715.54 BC 715.04 HP|TC 715.82 TC 715.32 BC 714.82 TC 714.79 BC 714.29 TC 714.57 BC 714.07 TC 714.98 BC 714.48 ME|G 719.03 ME|G 719.03 ME|G 718.94 ME|G 718.38 ME|G 718.36 ME|G 718.35 ME|G 718.34 ME|G 718.24 ME|G 718.35 ME|G 718.21 G 719.42 TC 719.14 BC 718.64 TC 717.49 BC 716.99 TC 717.73 BC 717.23 TC 717.97 BC 717.47 TC 718.21 BC 717.71 BC 715.86 TC 710.54 BC 710.04 HP|TC 715.71 TC 715.46 BC 714.96 G 717.56 G 717.71 G 717.94 G 718.06 G 718.26 TC 718.98 BC 718.48 TC 719.09 BC 718.59 TC 718.98 BC 718.48 G 718.26G 718.28 G 717.95G 717.99 G 717.69G 717.74 HP|TC 717.61 G 717.93 G 717.98 G 717.98 TC 718.81 BC 718.31 TC 718.82 BC 718.32 TC=BC 718.10 TC=BC 717.96 TC 718.66 BC 718.16 TC 718.75 BC 718.25 TC=BC 718.22 G 718.88 G 718.88 G 718.88G 718.88 G 719.20 G 719.19 G 719.18 G 719.17 ME|G 719.29 ME|G 719.19 ME|G 718.72 ME|G 719.24 TC 716.93 BC 716.43 TC 718.87 BC 718.37 TC 718.60 BC 718.10 G 716.98G 716.79 G 718.43 G 718.29 G 718.21G 718.01 ME|G 710.70 ME|G 712.55 ME|G 714.75 TC 714.92 BC 714.42 TC 714.87 BC 714.37 LP|TC 714.50 LP|TC 714.36 TC 719.29 BC 718.79 G 719.08 G 719.50G 719.02ME|G 719.01 ME|G 718.94 G 718.87 TC=BC 719.43 LP|TC 714.28 CO-4 BLDG-D CO-5 BLDG-E CO-6 CO-7 CO-9 BLDG-G BLDG-F CO-8 A-111 A-110 A-120 A-100 A-240 A-220 A-230 D-150 D-140 D-130 71 6 7 1 7 715 716 717 715 716 716 717 717 718 718 714 715 715716 716718 716 7177 1 8 717 716 713 716 G 715.74 G 715.68 G 714.87 G 714.47 G 714.36 G 711.09 G 712.95 G 717.13 G 716.90 G 712.51 G 712.41 G 712.20 G 712.10 G 714.10 G 714.00 G 717.14 G 717.21 1"=20' 0 2051020 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-GRAD-NJA220135.00-0A----->LAYOUT: C-404 - GRADING PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-GRAD PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-404 GRADING PLANMATCHLINE - SHEETC-403MATCHLINE - SHEETC-405NOTES: 1.COSTCO WILL NEED TO COORDINATE THE RELOCATION OF THE TELEPHONE LINE. 2.SEE STORM PROFILE SHEETS C-605 - C-616 FOR PROPOSED INVERTS AND RIM ELEVATIONS. 3.CONTRACTOR TO ADJUST SANITARY RIM ELEVATIONS PER RIM SPOT ELEVATION SHOWN. 4.OVERLAND RELIEF PATH OUTFALLS TO COSTELLO DRIVE. 5.ALL GRATE INLETS IN AREAS ACCESSIBLE TO THE PUBLIC WILL REQUIRED AN APPROPRIATELY SIZED GRATE OPENING. COST E L L O D R I V E 3 4 - 1 3 6 7 ES22°42'25"W (R) S19°55'24"W (M) 458.80' (R&M)PROP. SAWCUTLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP. SAWCUT R=460.00' (R&M) Δ=031°52'40" (R&M) L=255.93' (R&M) CHB=S68°30'18"E (R) CHB=N71°17'19"W (M) CHD=252.64' (R&M) R=1040.00' (R&M) Δ=008°18'13" (R&M) L=150.72' (R&M) CHB=N80°17'31"W (R) CHB=N83°04'32"W (M) CHD=150.59' (R&M) N84°26'38"W (R) N87°13'39"W (M) 129.72' (R&M) W E SNORTH ZONEVCS NAD83 /2011 PROP ROW PROP ROW LOWLOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW TOTAL LIMITS OF DISTURBANCE = 12.85 AC COST E L L O D R I V E 3 4 - 1 3 6 7 ES22°42'25"W (R) S19°55'24"W (M) 458.80' (R&M)PROP. SAWCUTLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP. SAWCUT R=460.00' (R&M) Δ=031°52'40" (R&M) L=255.93' (R&M) CHB=S68°30'18"E (R) CHB=N71°17'19"W (M) CHD=252.64' (R&M) R=1040.00' (R&M) Δ=008°18'13" (R&M) L=150.72' (R&M) CHB=N80°17'31"W (R) CHB=N83°04'32"W (M) CHD=150.59' (R&M) N84°26'38"W (R) N87°13'39"W (M) 129.72' (R&M) W E SNORTH ZONEVCS NAD83 /2011 PROP ROW PROP ROW LOWLOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW TOTAL LIMITS OF DISTURBANCE = 12.85 AC PROP FLUSH CURBPROP FLUSH CURB RIDGE RIDGECROWNRIDGECROWNRIDGE RIDG E PROP 12" HDPE PROP 1 2 " H D P E PROP 24" RCPPROP 3 6 " R C P PROP 36" RCP P R O P 3 6 " R C P PROP 36" RCP PROP 36" RCPPROP 30" RCPPROP 18" RCPPROP 18" RCP PROP 12" RCP PROP 12" HDPE PROP 12" HDPE PROP 12" HDPE PROP 24" RCP PROP 15" HDPE PROP 30" RCP PROP 18" RCP PROP 18 " R C P PROP 36" RCPPROP 8" HDPE PROP 8" HDPE PROP 8" HDPEPROP 8" HDPE 713WWWWWWWWWWWS SSSSSSPROP UNDG SWM SYSTEM #3 STORMTRAP OR APPROVED EQUAL STORAGE VOLUME = 49,571 CF STONE BASE = 697.25 BOTTOM OF CHAMBER = 699.00' TOP OF CHAMBER = 704.00' D D D D D DSLSL SPROP UNDG SWM SYSTEM #2 ADS STORMTECH CHAMBER SYSTEM STORAGE VOLUME = 25,250 CF STONE BASE = 703.16' BOTTOM OF CHAMBERS = 703.91' TOP OF SYSTEM = 709.91' C/O C/O C/O TP TP TP D D TTTTTTTTTTTP EXTENT OF FREDERICK WATER COMBINED WATER AND SEWER EASEMENT. SEWER BEYOND THIS EASEMENT IS PRIVATELY OWNED AND MAINTAINED. W D D D TC 716.20 BC 715.70 TC 716.44 BC 715.94 TC 716.68 BC 716.18 HP|TC 716.14 TC 716.44 BC 715.94 TC 715.96 BC 715.46 TC 717.04 BC 716.54 TC 717.73 BC 717.23 TC 717.97 BC 717.47 TC 714.44 BC 713.94 G 710.90 G 711.13 G 715.31 TC 715.16 BC 714.66 TC 714.74 BC 714.24 TC 715.36 BC 714.86 TC 714.94 BC 714.44 TC 714.33 BC 713.83 TC 714.56 BC 714.06 TC 714.90 BC 714.40 TC 714.87 BC 714.37 TC 714.79 BC 714.29 TC 716.34 BC 715.84 TC 715.53 BC 715.03 TC 715.73 BC 715.23 TC 715.58 BC 715.08 TC 714.36 BC 713.86 TC 715.14 BC 714.64 TC 714.60 BC 714.10 TC 715.92 BC 715.42 TC 716.14 BC 715.64 TC 716.23 BC 715.73 TC 716.54 BC 716.04 TC 716.79 BC 716.29 TC 715.32 BC 714.82 TC 714.79 BC 714.29 TC 714.57 BC 714.07 TC 714.98 BC 714.48 TC 715.72 BC 715.22 TC 715.51 BC 715.01 TC 715.65 BC 715.15 TC 715.86 BC 715.36 G 715.44 TC 716.07 BC 715.57 TC 716.51 BC 716.01 TC 716.80 BC 716.30 TC 716.87 BC 716.37 TC 716.50 BC 716.00 TC 715.09 BC 714.59 TC 716.00 BC 715.50 TC 715.96 BC 715.46 TC 716.49 BC 715.99 TC 716.85 BC 716.35 TC 717.15 BC 716.65 TC 713.09 BC 712.59 TC 713.61 BC 713.11 TC 714.12 BC 713.62 TC 713.45 BC 712.95 TC 713.74 BC 713.24 TC 716.29 BC 715.79 G 715.98 TC 715.37 BC 714.87 TC 715.46 BC 714.96 TC 712.11 BC 711.61 TC 711.97 BC 711.47 G 711.88 G 716.12 HP|TC 716.79 TC 716.44 BC 715.94 TC 714.25 BC 713.75 TC 712.81 BC 712.31 TC 716.14 BC 715.64 TC 712.63 BC 712.13 TC 715.18 BC 714.68 TC 715.45 BC 714.95 TC 716.86 BC 716.36 TC 717.18 BC 716.68 TC 715.08 BC 714.58 TC 717.38 BC 716.88 TC 717.14 BC 716.64 TC 717.02 BC 716.52 HP 716.84 G 716.21 TC 717.17 BC 716.67 TC 717.37 BC 716.87 TC 717.09 BC 716.09 TC 716.11 BC 715.11 TC 717.15 BC 716.15 TC 716.13 BC 715.13 G 715.11 ME|G 718.35 TC 717.21 BC 716.21 TC 718.03 BC 717.53 G 717.12G 717.93 G 719.42 TC 719.14 BC 718.64 TC 718.07 BC 717.57 G 716.21 G 715.11 G 715.11 G 715.03G 715.03 BC 715.11 HP|TC 717.04 TC 717.49 BC 716.99 TC 717.73 BC 717.23 TC 717.97 BC 717.47 TC 718.21 BC 717.71 TC 715.59 BC 715.09 TC 716.36 BC 715.86 TC 711.40 BC 710.90 TC 704.96 BC 704.46 TC 706.83 BC 706.33 TC 713.38 BC 712.88 ME|G 710.20 ME|G 709.87 ME|G 709.71 ME|G 709.42 ME|G 708.53 TC 710.54 BC 710.04 G 715.61TC 716.61 BC 715.61 TC 716.61 BC 715.61 TC 716.93 BC 716.43 TC 716.73 BC 716.23 TC 716.80 BC 716.30 ME|G 710.70 G 715.91 HP 716.01 TC 716.20 BC 715.70 TC 716.82 BC 716.32 HP|TC 716.90 TC 716.34 BC 715.84 TC 715.89 BC 715.39 TC 716.10 BC 715.60 TC 716.02 BC 715.52 G 709.32 TC 708.79 BC 708.29 TC 708.08 BC 707.58 G 709.24 G 708.18 G 708.28 TC 713.55 BC 713.05 TC 715.03 BC 714.53 TC 719.29 BC 718.79 G 719.08 G 719.50G 719.02ME|G 719.01 ME|G 718.94 G 718.87 TC=BC 719.43 TC 716.71 BC 716.21 TC 704.66 BC 704.16 TC 704.80 BC 704.30 TC 704.59 BC 704.09 TC 704.78 BC 704.28 TC 705.95 BC 705.45 G 706.04 G 706.16 G 705.57 G 705.67 TC 705.48 BC 704.98 TC 713.14 BC 712.64 TC 713.50 BC 713.00 TC 713.89 BC 713.39 TC 712.86 BC 712.36 LP|TC 714.28 TC 711.20 BC 710.70 C-210 CO-10 BLDG-H CO-11 C-10ABLDG-I RIM 713.00 RIM 714.16 RIM 713.77 C-112 RIM 717.26 B-150 C-121.1 B-140 B-150 A-200 B-120 D-220 D-210 B-110 B-100 EX-5 C-111 C-110 C-121.2 C-112A C-100 C-120 C-122 D-130 B-131 D-120 C-220 C-230 B-111 D-110 EX-6 A-210 716 710712713714715716 704705 706 707 708 709 710 711712713714 715715716716716716717716 717 718703704705706707708713714714714715714 716716 710 711 712 713 714 715 716 710713714715716716707 708 709710711712 713 714 715 716717 71671471570 0 701 70 2 70 3 704 705 704704703 703 TC 715.42 BC 715.17 TC 715.18 BC 714.93 TC 713.99 BC 713.74 TC 713.93 BC 713.68 TC 713.53 BC 713.28 TC 713.46 BC 713.21 TC 712.71 BC 712.46 TC 713.51 BC 713.26 TC 713.60 BC 713.35 TC 713.25 BC 713.00 TC 714.84 BC 714.59 TC 714.72 BC 714.47 LP|TC 714.94 LP|TC 713.67 TC 710.82 G 711.52 G 711.09 G 711.40 G 707.30 G 712.60 G 713.29 G 711.52 G 714.33 G 717.30 TC 705.65 G 711.75 G 711.94 G 711.29 G 711.22 G 711.47 G 711.54 1"=20' 0 2051020 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-GRAD-NJA220135.00-0A----->LAYOUT: C-405 - GRADING PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-GRAD PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-405 GRADING PLAN MATCHLINE - SHEET C-406 MATCHLINE - SHEETC-404NOTES: 1.COSTCO WILL NEED TO COORDINATE THE RELOCATION OF THE TELEPHONE LINE. 2.SEE STORM PROFILE SHEETS C-605 - C-616 FOR PROPOSED INVERTS AND RIM ELEVATIONS. 3.CONTRACTOR TO ADJUST SANITARY RIM ELEVATIONS PER RIM SPOT ELEVATION SHOWN. 4.OVERLAND RELIEF PATH OUTFALLS TO COSTELLO DRIVE. 5.ALL GRATE INLETS IN AREAS ACCESSIBLE TO THE PUBLIC WILL REQUIRED AN APPROPRIATELY SIZED GRATE OPENING. S60°23'46"E (R) S63°10'47"E (M) 852.51' (R&M)S23°22'33"W (R)S20°35'32"W (M)82.25' (R&M)S22°42'25"W (R) S19°55'24"W (M) 458.80' (R&M)PROP. SAWCUT TOTAL LIMITS OF DISTURBANCE = 12.85 AC LODLODLODLODLODLODLODLOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /201159.3'S60°23'46"E (R) S63°10'47"E (M) 852.51' (R&M)S23°22'33"W (R)S20°35'32"W (M)82.25' (R&M)S22°42'25"W (R) S19°55'24"W (M) 458.80' (R&M)PROP. SAWCUT TOTAL LIMITS OF DISTURBANCE = 12.85 AC LODLODLODLODLODLODLODLOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /201159.3'PROP GAS ATTENDANT BUILDING 84.3' PROP FUEL CANOPY WITH 32 FUELING POSITIONS HEIGHT = 19.5' PROP BUILDING EXPANSION FOOTPRINT AREA=20,709 SF FFE = 719.28 HEIGHT = 30.5' PROP FOUR (4) BAYS T PROP TRANSFORMER PROP MASONRY SCREENING WALL FOR TRASH COMPACTORS 20' FREDERICK WATER EASEMENT FOR FUTURE WATERMAIN EXTENSION (TYP) PROP TRANSFORMER PROP BATHROOM FOR ATTENDANT 59.2'PROP GAS ATTENDANT BUILDING 84.3' PROP FUEL CANOPY WITH 32 FUELING POSITIONS HEIGHT = 19.5' PROP BUILDING EXPANSION FOOTPRINT AREA=20,709 SF FFE = 719.28 HEIGHT = 30.5' PROP FOUR (4) BAYS T PROP TRANSFORMER PROP MASONRY SCREENING WALL FOR TRASH COMPACTORS 20' FREDERICK WATER EASEMENT FOR FUTURE WATERMAIN EXTENSION (TYP) PROP TRANSFORMER PROP BATHROOM FOR ATTENDANT 59.2'RIDGERIDGE RIDGE RIDGE RIDGEPROP 6" HDPEPROP 6" HDPEPROP 6" HDPEPROP 6" HDPE PROP 4" HDPE PROP 4" HDPE PROP 4" HDPE PROP 6" HDPE PROP 4" HDPE PROP 6" HDPE PROP 6" HDPE PROP 4" HDPE PROP 4" HDPE PROP 4" HDPE PROP 4" HDPE PROP 4" HDPEPROP 4" HDPE PROP 30" RCPPROP 18" RCPPROP 15 " RCP PROP 12" HDPE PROP 18" RCPPROP 12" RCPPROP 12" RCP PROP 15" HDPE PROP 24" RCP PROP 8" HDPE PROP 15" HDPEPROP 15" HDPEPROP 4" HDPEPROP 4" HDPE PROP 8" HDPE PROP 8" HDPE PROP 8" HDPE PROP 8" HDPEPROP 8" HDPE PROP 8" HDPE PROP 8" HDPEPROP 8" HDPE PROP 8" HDPE PROP 8" HDPEPROP 8" HDPE PROP 6" HDPEPROP 6" HDPE D SSPROP SHUTOFF VALVE WWWWWWWWWWWWWWWWWWWWWWWWSSSL SL SL SSSSSSSSSSSSSSSS 20' FREDERICK WATER EASEMENT (TYP) 20' FREDERICK WATER EASEMENT TP DTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT T T E E EEEEEEEEEEEEEEEE E EEEEEEEEEEEEEE DD PROP OIL/WATER SEPARATOR TP SL D D PROP 8" PVC TP WW20' FREDERICK WATER EASEMENT PROP 6" HDPE PROP 6" HDPE PROP 6" HDPE PROP 6" HDPE PROP 4" HDPE PROP 4" HDPE PROP 4" HDPE PROP 4" HDPE PROP 8" HDPE TC 715.53 BC 715.03 TC 715.73 BC 715.23 TC 715.58 BC 715.08 TC 714.36 BC 713.86 TC 715.14 BC 714.64 TC 714.60 BC 714.10 TC 715.92 BC 715.42 TC 716.14 BC 715.64 TC 716.05 BC 715.55 TC 716.27 BC 715.77 TC 717.00 BC 716.50 TC 716.54 BC 716.04 TC 716.49 TC 716.85 BC 716.35 TC 717.15 BC 716.65 TC 717.72 BC 717.22 TC 716.34 BC 715.84 TC 713.74 TC 716.11 BC 715.11 TC 716.13 BC 715.13 G 715.11 TC 718.03 BC 717.53 TC 718.52 BC 718.02 TC 719.22 BC 718.72 TC 718.70 BC 718.20 TC 718.59 BC 718.09 TC 716.73 BC 716.23 TC 716.09 BC 715.59 TC 717.63 BC 717.13 TC 718.08 BC 717.58 TC 717.25 BC 716.75 TC 718.81 BC 718.31 TC 718.85 BC 718.35 TC 718.90 BC 718.40 TC 718.93 BC 718.43 TC 719.06 BC 718.56 TC 718.76 BC 718.26 G 717.80G 717.97 HP 719.28 HP 719.28 FF 719.28 FF 719.28 FF 719.28 TC 717.25 BC 716.75 TC 717.56 BC 717.06 TC 719.00 BC 718.50 TC 719.02 BC 718.52 TC 719.08 BC 718.58 HP|TC 719.10 TC 719.65 BC 719.15 TC 719.70 BC 719.20 TC 718.96 BC 718.46 TC 718.76 BC 718.26 TC 719.63 BC 719.13 TC 716.88 BC 716.38 TC 716.00 BC 715.50 TC 716.13 BC 715.63 TC 716.31 BC 715.81 TC 719.21 BC 718.71 TC 719.40 BC 718.90 TC 718.18 BC 717.68 TC 718.42 BC 717.92 TC 718.64 BC 718.14 ME|BC 718.24 ME|G 718.27 ME|G 718.34 ME|BC 718.52 G 719.21 G 715.11 G 715.11 G 715.03G 715.03 TC 716.11 BC 715.11 FF 719.28 FF 719.28 FF 719.28 FF 719.28 G 719.95 G 719.28 TC 718.82 BC 718.32 TC 717.96 BC 717.46 G 717.90 G 717.81 G 719.17 TI 718.65 TC 718.96 BC 718.46 FF 718.95 FF 718.95 G 718.18 G 718.12 TI 718.36 G 717.90 G 717.84 TI 717.99 G 717.60 G 717.53 TI 717.66 G 717.27 G 717.20 G 717.37G 717.70 G 718.04 G 717.98 TI 718.80 G 718.26 TI 718.91 G 718.43 G 718.32 TI 718.66 G 718.20 G 718.14 TI 718.43 G 717.96 G 717.89 TI 718.17 G 717.71 G 717.60 G 718.32 G 717.77 G 717.45 TI 718.52 TI 718.25 TI 717.92 G 718.93 G 718.37 G 718.76 G 719.00 FF 719.28 G 720.02 G 719.28 TC 715.67 BC 715.17 TC 714.50 BC 714.00 TC 714.50 BC 714.00 G 717.97 G 717.32 G 718.33 G 718.07 G 718.06 G 717.94 G 718.45 G 718.63 G 718.79 TC 718.88 BC 718.38 HP|TC 716.50 HP|TC 715.93 TC 719.65 BC 719.15 TC 719.63 BC 719.13 CNPY-G CNPY-C CNPY-A CNPY-B CNPY-DCNPY-F CNPY-H CNPY-L CNPY-K CNPY-J CNPY-I C-150 CO-10 BLDG-H BLDG-J BLDG-K CO-13 BLDG-L CO-15 CO-17 BLDG-M CO-16 CO-18 BLDG-N CO-19 BLDG-O CO-12 CO-11 C-10ABLDG-I RIM 715.51 RIM 716.99 RIM 714.16 C-140 C-112 RIM 717.26 CO-23 WYE-10 WYE-11WYE-12WYE-13 CNPY-O CNPY-N CNPY-M CNPY-P C-160 C-113 C-111 C-110 WYE-9 WYE-5 WYE-8 WYE-4 WYE-7 WYE-2 CO-22 C-141 WYE-1 C-143 C-141A C-112A C-130 C-120 C-142 CO-21 CO-14 WYE-3 WYE-6 CNPY-E 715 716718718717718 715716717718 719 720 721 722 718 719 720 719 71371471 4 714715715715716717718 716717 718719707708709715714 718 719 720 717 718 719719718 719 717 716715716717719FF 719.00 FF 719.02 TC 718.07 BC 717.57 G 718.07 TI 718.54 G 718.02 G 717.74 G 717.68 G 717.42 G 717.34 G 717.00 G 717.06 TI 717.52TI 717.87TI 718.20 G 714.33 G 717.30 G 718.17 G 714.06 LP 716.50 1"=20' 0 2051020 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-GRAD-NJA220135.00-0A----->LAYOUT: C-406 - GRADING PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-GRAD PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-406 GRADING PLAN MATCHLINE - SHEET C-405 NOTES: 1.COSTCO WILL NEED TO COORDINATE THE RELOCATION OF THE TELEPHONE LINE. 2.SEE STORM PROFILE SHEETS C-605 - C-616 FOR PROPOSED INVERTS AND RIM ELEVATIONS. 3.CONTRACTOR TO ADJUST SANITARY RIM ELEVATIONS PER RIM SPOT ELEVATION SHOWN. 4.OVERLAND RELIEF PATH OUTFALLS TO COSTELLO DRIVE. 5.ALL GRATE INLETS IN AREAS ACCESSIBLE TO THE PUBLIC WILL REQUIRED AN APPROPRIATELY SIZED GRATE OPENING. FRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW FRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW PROP C U R B AND GU T T E R CONCRE T E P A D PROP C U R B AND GU T T E R CONCRE T E P A D SEE SHE E T C - 7 0 1 F O R DETAIL G R A D I N G O F THE FRO N T R O Y A L P I K E TURN LA N E W ESNAD83NAD83TC 723.96 BC 723.46 TC 723.82 BC 723.32 TC 724.09 BC 723.59 TC 724.33 BC 723.83 HP|TC 725.21 TC 723.68 BC 723.18 TC 724.24 BC 723.74 TC 723.88 BC 723.38 TC 723.74 BC 723.24 TC 724.08 BC 723.58 TC 724.78 BC 724.28 TC 724.80 BC 724.30 TC 724.85 BC 724.35 ME|BC 724.33 TC 724.47 BC 723.97 ME|G 724.36 ME|G 723.98 TC 724.97 BC 724.47 TC 724.67 BC 724.17 TC 724.59 BC 724.09 TC 724.53 BC 724.03 TC 724.53 BC 724.03 TC 724.53 BC 724.03 TC 724.83 BC 724.33 TC 724.61 BC 724.11 724 7 2 5 726725G 724.85 G 725.61 G 725.69 G 725.76 G 725.70 G 725.51 G 725.53 G 725.69 G 725.79 TC=BC 725.75 TC=BC 725.82 TC 725.86 TC 725.81 TC 725.96 TC 725.89 TC 725.95 TC 725.97 TC 726.03 TC 726.13 LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP. SAWCUT LOD LOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP. SAWCUT LOD LOD LOD LOD LODLOD LOD LOD LOD LOD 37' 19.7' 17.3' 37' 19.7' 17.3'RIDGE W E SNAD83 NAD83TC 715.87 BC 715.37 TC 716.00 BC 715.50 TC 716.41 BC 715.91 TC 717.28 BC 716.78 G 716.82 G 717.02 D-150 716 TC 715.70 TC 715.54 TC=BC 715.82 TC=BC 715.75 TC 716.24 TC 716.11 TC=BC 716.27 TC=BC 716.19 TC=BC 715.90 TC=BC 715.94 G 715.68 TC 715.82 TC 715.75 G 717.13 G 716.90 TC 716.18 TC 716.27 TC 716.19 G 715.24 G 715.06 G 715.67 G 715.79 G 717.14 G 717.21 LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP. SAWCUT TOTAL LIMITS OF DISTURBANCE = 12.85 AC LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP. SAWCUT TOTAL LIMITS OF DISTURBANCE = 12.85 AC 18.5'17.5'5'18.5'17.5'5'CROWNPROP 12" HDPE D W E SNAD83 NAD83TC 714.44 BC 713.94 G 710.90 G 711.13 TC 712.11 BC 711.61 TC 711.97 BC 711.47 G 711.88 ME|G 710.20 ME|G 709.87 ME|G 709.71 ME|G 709.42 TC=BC 709.66 TC 709.83 TC 711.20 BC 710.70 D-220 D-210 D-120 A-210 710 711 712 713TC=BC 709.53 TC=BC 709.74 TC=BC 709.60 TC 709.75 TC 710.67 TC 710.82 TC 710.83 TC 710.68 TC=BC 710.83 TC=BC 710.76 TC 709.85 TC 709.89 TC 710.76 G 711.52 G 711.40 TC 709.82 G 711.75 G 711.94 G 710.12 G 710.14 G 709.28 G 709.19 G 711.29 G 711.22 G 711.47 G 711.54 PROP. SAWCUT LODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP ROW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW PROP. SAWCUT LODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP ROW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW10'20' 3 16'18.19'10'20' 3 16'18.19' P R O P 3 6 " R C P PROP 36" RCP PROP 36" RCP PROP 36" RCPD D D D W E SNAD83 NAD83TC 703.69 BC 703.19 TC 714.25 BC 713.75 TC 704.96 BC 704.46 TC 713.38 BC 712.88 TC 704.66 BC 704.16 TC 704.80 BC 704.30 TC 704.59 BC 704.09 TC 703.61 BC 703.11 TC 703.39 BC 702.89 TC 703.11 BC 702.61 TC 703.13 BC 702.63 TC 704.78 BC 704.28 TC 702.99 TC 703.20 BC 702.70 TC 703.32 BC 702.82 B-110 B-100 EX-5 B-111 704705 70 2 70 3 704 704704703 703 TC 704.93 TC 704.84 TC=BC 704.79 TC 704.77 TC=BC 704.88 TC 704.64 TC 702.73 TC=BC 702.41 TC=BC 702.49 TC 702.87 TC 702.79 TC 705.65 G 704.19 G 704.07 G 702.15 G 702.43 1"=20' 0 2051020 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-GRAD-NJA220135.00-0A----->LAYOUT: C-407 GRADING PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-GRAD PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-407 GRADING PLAN NOTES: 1.COSTCO WILL NEED TO COORDINATE THE RELOCATION OF THE TELEPHONE LINE. 2.SEE STORM PROFILE SHEETS C-605 - C-616 FOR PROPOSED INVERTS AND RIM ELEVATIONS. 3.CONTRACTOR TO ADJUST SANITARY RIM ELEVATIONS PER RIM SPOT ELEVATION SHOWN. 4.OVERLAND RELIEF PATH OUTFALLS TO COSTELLO DRIVE. 5.ALL GRATE INLETS IN AREAS ACCESSIBLE TO THE PUBLIC WILL REQUIRED AN APPROPRIATELY SIZED GRATE OPENING. INSET 1 - FRONT ROYAL PIKE INTERSECTION INSET 2 - COSTELLO DRIVE INTERSECTION INSET 3 - COSTELLO DRIVE INTERSECTION INSET 4 - COSTELLO DRIVE INTERSECTION SCALE = 1" = 20' SCALE = 1" = 10'SCALE = 1" = 10' SCALE = 1" = 10' PROP FUEL CANOPY WITH 32 FUELING POSITIONS HEIGHT = 19.5' PROP BUILDING EXPANSION FOOTPRINT AREA=20,709 SF FFE = 719.28 HEIGHT = 30.5' PROP 5' SIDEW A L K PROP 5' SIDEW A L KPROP 5' SIDEWALKPROP 5' SIDEWALKFRONT ROYAL PIKE - U.S. ROUTE 522LOT 1 GARBER ESTATE SUBDIVISION D.B. 838 PG. 1360 LANDS OF THE PRICE COMPANY D.B. 829 PG. 487 TM: 64-8-1 AREA: 13.002 AC. (R&M) OR 566,356 S.F. (M) ZONING: B2 N46°13'28"E 367.43'COSTEL L O D R I V E 3 4 - 1 3 6 7 ELODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLOD LODLODLODLODLODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011LOWLOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOD LOD LOD LOD LOD LOD LOD LOD LOD LOWLOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW LOW D SSWWWWWWWWWWWSSD D D D D D D D SL SSSSSSC/OC/O C/O D D TTTTTTTTTTTTTTTT EEEEEEEEEE DD D D D D 13+71.01 10+00 11+0012+0013+0010+5011+5012+5013+5014+57.96 10+00 11+0012+0013+0014+0010+5011+5012+50 13+501 4 + 5 0 10+10.41 10+00 10+16.80 10+00 10+47.75 10+00 10+34.94 10+00 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-UTIL-NJA220135.00-0A----->LAYOUT: C-501 OVERALL UTILITY PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-UTIL PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-504 C-505 C-502 C-503 0 SCALE:1" = 50' 50 5012.525 C-501 OVERALL UTILITY PLAN C-506 PROP CURB PROP CURB AND GUTTER CONCRETE PAD PROP LIGHT (TYP)PROP 5' SIDEWALKFRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'S60°23'46"E (R) S63°10'47"E (M) 290.40' (R&M)N49°00'29"E (R)N46°13'28"E (M)159.00' (R&M)PROP. SAWCUT LIMITS OF DISTURBANCE = 12.85 AC LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLOD LODLODLODLODPROP. SAWCUT W E SNORTH ZONEVCS NAD83 /2011 W 98.9'LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW PROP. SAWCUT TP TP TP TPTPTP 20' FREDERICK WATER EASEMENT18" RCP8" HDPE 8" HDPE 8" HDPE 8" HDPE8" HDPE8" HDPE 8" HDPE8" HDPE 8" HDPE A-150 A-140 BLDG-B BLDG-C BLDG-D BLDG-E CO-3 CO-2 CO-4 CO-5 BLDG-A CO-1 F-100 CONTRACTOR TO CONNECT PROPOSED FIRE HYDRANT TO EXISTING WATERLINE. COORDINATE FIELD CONNECTION WITH CITY OF WINCHESTER. CONTRACTOR TO FIELD VERIFY LOCATION OF TELECOM LINE AND RELOCATE AROUND PROPOSED CURB INLET. CONTRACTOR TO OUTLET UD-4 UNDERDRAIN (TYP) PROP UD-4 (TYP) 0 SCALE:1" = 20' 20 20510 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-UTIL-NJA220135.00-0A----->LAYOUT: C-502 UTILITY PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-UTIL PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-502 UTILITY PLAN MATCHLINE - SHEET C-503 UTILITY NOTES: 1.WATER AND SANITARY SEWER LINES LOCATED WITHIN THE EXISTING OR PROPOSED WATER & SEWER EASEMENT ARE OWNED BY FREDERICK WATER OR CITY OF WINCHESTER AS LABELED PER PLAN. 2.SANITARY LATERALS, GREASE TRAPS AND SAND SEPARATOR ARE TO BE OWNED AND MAINTAINED BY COSTCO WHOLESALE. 3.ALL PROPOSED FIRE LINES ARE TO BE RESTRAINED. 4.CONTRACTOR TO PROVIDE TEMPORARY PIPING FOR ALL PROPOSED SERVICE INTERRUPTIONS TO THE EXISTING SANITARY LINE. 5.THE CITY OF WINCHESTER SHALL PROVIDE INSPECTION OF THEIR FACILITIES AS APPLICABLE. 6.UNDERDRAINS (UD-4) HAVE BEEN SPECIFIED BENEATH ALL NEW CURB AND GUTTER SECTIONS WITHIN VDOT ROW. 7.PRIVATELY OWNED SANITARY SEWER INSTALLATIONS OR MODIFICATIONS SHALL BE PERFORMED TO ELIMINATE OR REDUCE INFLOW AND INFILTRATION. CONTRACTOR SHALL REVIEW WORK WITH THE FREDERICK WATER INSPECTOR. 8.IF EXISTING TELEPHONE OR OTHER ENCROACHMENTS ARE MODIFIED BEYOND AS SHOWN ON THESE PLANS THEY SHALL COMPLY WITH CURRENT FREDERICK WATER REQUIREMENTS AND BE COORDINATED WITH THE FREDERICK WATER INSPECTOR FREDERICK WATER NOTES: 1.VALVES, MANHOLES, ARV'S AND OTHER FREDERICK WATER SURFACE FEATURES SHALL NOT BE PLACED IN CURB AND GUTTER, NOR SLOPED PORTION OF HANDICAPPED RAMPS. CONTRACTOR SHALL COORDINATE LOCATIONS WITH THE FREDERICK WATER INSPECTOR. 2.IRRIGATION LINES AND DEVICES, LIGHT POLES, TRANSFORMERS, JUNCTION BOXES, PEDESTALS, OTHER OBSTACLES AND ALL DRY UTILITIES SHALL NOT BE PLACED ON FREDERICK WATER EASEMENTS. PERPENDICULAR IRRIGATION LINES AND DRY UTILITY CROSSINGS ARE PERMITTED WITH 18" MINIMUM VERTICAL SEPARATION. 3.RETAINING WALLS AND THEIR TIE BACKS SUCH AS GEO GRID OR OTHER SUPPORTS SHALL NOT BE PLACED IN FREDERICK WATER EASEMENTS 4.UNDER THE FOLLOWING CIRCUMSTANCES, DEVELOPMENT REQUIRING FIRE HYDRANTS SHALL PROVIDE AT LEAST ONE KENNEDY IHYDRANT OR MUELLER SUPER CENTURION WITH HYDRO-GUARD FOR REMOTE PRESSURE AND TEMPERATURE MONITORING. THE DEVELOPER OR HIS/HER AGENT SHALL PROCURE A TWO-YEAR MONITORING CONTRACT FOR THE MONITORING SERVICE AND TELEMETRY AND PROVIDE ACCESS TO FREDERICK WATER ONCE THE SUBSCRIPTION IS ACTIVE. THE FREDERICK WATER INSPECTOR SHALL CHOOSE WHICH OF THE REQUIRED HYDRANTS SHALL BE A KENNEDY IHYDRANT OR MUELLER SUPER CENTURION. 1. EACH RESIDENTIAL SITE PLAN (EACH INDEPENDENTLY SUBMITTED SECTION AND/OR PHASE) 2. ANY COMMERCIAL OR INDUSTRIAL SITE PLAN WHICH HAS THREE (3) OR MORE FIRE HYDRANTS GREASE TRAP / OIL WATER SEPARATOR / SAND SEPARATOR NOTES: 1.TANK SECTIONS SHALL BE BOLTED TOGETHER. 2.WATERTIGHT BOLT DOWN FRAME AND COVERS ARE REQUIRED. 3.PENETRATIONS SHALL HAVE BOOTS. 4.TANK, COMPONENTS, AND INSTALLATIONS SHALL BE TRAFFIC RATED. 5.CONTRACTOR SHALL COORDINATE INSTALLATION AND INSPECTIONS WITH BOTH FREDERICK COUNTY INSPECTIONS DEPARTMENT AND FREDERICK WATER WATER MAIN CONNECTION NOTES CONTRACTOR SHALL: 1.TEST PIT THE EXISTING MAINS IN ACCORDANCE WITH FREDERICK WATER INSPECTOR'S REQUIREMENTS. 2.INSTALL JOINT RESTRAINTS ON EXISTING MAINS PER CURRENT FREDERICK WATER STANDARDS PRIOR TO SHUTDOWN. 3.PREPARE ALL WORK AS FAR IN ADVANCE AS POSSIBLE TO MINIMIZE SHUTDOWN TIME. 4.ENSURE SUFFICIENT RESOURCES (LABOR, EQUIPMENT, MATERIALS) ARE ON-SITE TO COMPLETE THE WORK IN COMPLIANCE WITH FREDERICK WATER INSPECTOR'S EXPECTATIONS. 5.PREPARE A SHUTDOWN PLAN SATISFACTORY TO THE FREDERICK WATER INSPECTOR. THIS MAY INCLUDE FIRE WATCH, NIGHT WORK, OR OTHER REQUIREMENTS. 6.SCHEDULE THE SHUTDOWN WITH THE FREDERICK WATER INSPECTOR, FREDERICK COUNTY FIRE MARSHAL, AND ALL AFFECTED CUSTOMERS AT LEAST SEVEN (7) DAYS IN ADVANCE, AND MAKE ALL NECESSARY PREPARATIONS AS REQUIRED BY ALL PARTIES. 7.COORDINATE ALL CUT-IN TEE AND VALVES WITH ONE SINGLE SHUT DOWN OF WATER. PROP 5' SIDE W A L K PROP 5' SIDEWALKPROP LIGHT (TYP)PROP 5' SIDEWALKPROP SIGHT DISTANCE EASEMENTFRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'PROP. SAWCUT LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP. SAWCUT PROP. SAWCUT PROP. SAWCUT COSTELL O D R I V E 3 4 - 1 3 6 7 E R=50.00' (R&M) Δ=101°34'27" (R&M) L=88.64' (R&M) CHB=N01°46'45"W (R) CHB=N04°33'46"W (M) CHD=77.48' (R&M) W E SNORTH ZONEVCS NAD83 /2011 W 232.7'PROP. SAWCUT LOWLOWLOW LOWLOWLOWTOTAL LIMITS OF DISTURBANCE = 12.85 AC LOD LOD LOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD PROP ROW PROP ROWLOWLOWLOWLOWLOWLOWLOWLOWLOWPROP. SAWCUT PROP. SAWCUT VARIABLE STORM DRAINAGE EASEMENT VARIABLE STORM DRAINAGE EASEMENT TP TP TP TP 24" RCP15" RCP 24" RCP 30" RCP 12" HDPE 15" RCP 15" RCP12" HDPE8" HDPE8" HDPE8" HDPE8" HDPE 8" HDPE8" HDPE A-133 A-122 A-132 A-121 A-131 A-130 A-120 BLDG-D BLDG-E CO-4 CO-5 CO-7 CO-6 D-170 D-160 D-150 18" RCP 18" RCP CONTRACTOR TO CONNECT PROPOSED FIRE HYDRANT TO EXISTING WATERLINE. COORDINATE FIELD CONNECTION WITH CITY OF WINCHESTER. F-110 PROP 15" RCP CONTRACTOR TO FIELD VERIFY LOCATION OF TELECOM LINE AND RELOCATE AROUND PROPOSED CURB INLET. CONTRACTOR TO OUTLET UD-4 UNDERDRAIN (TYP) PROP UD-4 (TYP) PROP UD-4 (TYP) May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-UTIL-NJA220135.00-0A----->LAYOUT: C-503 UTILITY PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-UTIL PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-503 UTILITY PLANMATCHLINE - SHEETC-504MATCHLINE - SHEET C-502 1"=20' 0 2051020 UTILITY NOTES: 1.WATER AND SANITARY SEWER LINES LOCATED WITHIN THE EXISTING OR PROPOSED WATER & SEWER EASEMENT ARE OWNED BY FREDERICK WATER OR CITY OF WINCHESTER AS LABELED PER PLAN. 2.SANITARY LATERALS, GREASE TRAPS AND SAND SEPARATOR ARE TO BE OWNED AND MAINTAINED BY COSTCO WHOLESALE. 3.ALL PROPOSED FIRE LINES ARE TO BE RESTRAINED. 4.CONTRACTOR TO PROVIDE TEMPORARY PIPING FOR ALL PROPOSED SERVICE INTERRUPTIONS TO THE EXISTING SANITARY LINE. 5.THE CITY OF WINCHESTER SHALL PROVIDE INSPECTION OF THEIR FACILITIES AS APPLICABLE. 6.UNDERDRAINS (UD-4) HAVE BEEN SPECIFIED BENEATH ALL NEW CURB AND GUTTER SECTIONS WITHIN VDOT ROW. 7.PRIVATELY OWNED SANITARY SEWER INSTALLATIONS OR MODIFICATIONS SHALL BE PERFORMED TO ELIMINATE OR REDUCE INFLOW AND INFILTRATION. CONTRACTOR SHALL REVIEW WORK WITH THE FREDERICK WATER INSPECTOR. 8.IF EXISTING TELEPHONE OR OTHER ENCROACHMENTS ARE MODIFIED BEYOND AS SHOWN ON THESE PLANS THEY SHALL COMPLY WITH CURRENT FREDERICK WATER REQUIREMENTS AND BE COORDINATED WITH THE FREDERICK WATER INSPECTOR FREDERICK WATER NOTES: 1.VALVES, MANHOLES, ARV'S AND OTHER FREDERICK WATER SURFACE FEATURES SHALL NOT BE PLACED IN CURB AND GUTTER, NOR SLOPED PORTION OF HANDICAPPED RAMPS. CONTRACTOR SHALL COORDINATE LOCATIONS WITH THE FREDERICK WATER INSPECTOR. 2.IRRIGATION LINES AND DEVICES, LIGHT POLES, TRANSFORMERS, JUNCTION BOXES, PEDESTALS, OTHER OBSTACLES AND ALL DRY UTILITIES SHALL NOT BE PLACED ON FREDERICK WATER EASEMENTS. PERPENDICULAR IRRIGATION LINES AND DRY UTILITY CROSSINGS ARE PERMITTED WITH 18" MINIMUM VERTICAL SEPARATION. 3.RETAINING WALLS AND THEIR TIE BACKS SUCH AS GEO GRID OR OTHER SUPPORTS SHALL NOT BE PLACED IN FREDERICK WATER EASEMENTS 4.UNDER THE FOLLOWING CIRCUMSTANCES, DEVELOPMENT REQUIRING FIRE HYDRANTS SHALL PROVIDE AT LEAST ONE KENNEDY IHYDRANT OR MUELLER SUPER CENTURION WITH HYDRO-GUARD FOR REMOTE PRESSURE AND TEMPERATURE MONITORING. THE DEVELOPER OR HIS/HER AGENT SHALL PROCURE A TWO-YEAR MONITORING CONTRACT FOR THE MONITORING SERVICE AND TELEMETRY AND PROVIDE ACCESS TO FREDERICK WATER ONCE THE SUBSCRIPTION IS ACTIVE. THE FREDERICK WATER INSPECTOR SHALL CHOOSE WHICH OF THE REQUIRED HYDRANTS SHALL BE A KENNEDY IHYDRANT OR MUELLER SUPER CENTURION. 1. EACH RESIDENTIAL SITE PLAN (EACH INDEPENDENTLY SUBMITTED SECTION AND/OR PHASE) 2. ANY COMMERCIAL OR INDUSTRIAL SITE PLAN WHICH HAS THREE (3) OR MORE FIRE HYDRANTS GREASE TRAP / OIL WATER SEPARATOR / SAND SEPARATOR NOTES: 1.TANK SECTIONS SHALL BE BOLTED TOGETHER. 2.WATERTIGHT BOLT DOWN FRAME AND COVERS ARE REQUIRED. 3.PENETRATIONS SHALL HAVE BOOTS. 4.TANK, COMPONENTS, AND INSTALLATIONS SHALL BE TRAFFIC RATED. 5.CONTRACTOR SHALL COORDINATE INSTALLATION AND INSPECTIONS WITH BOTH FREDERICK COUNTY INSPECTIONS DEPARTMENT AND FREDERICK WATER WATER MAIN CONNECTION NOTES CONTRACTOR SHALL: 1.TEST PIT THE EXISTING MAINS IN ACCORDANCE WITH FREDERICK WATER INSPECTOR'S REQUIREMENTS. 2.INSTALL JOINT RESTRAINTS ON EXISTING MAINS PER CURRENT FREDERICK WATER STANDARDS PRIOR TO SHUTDOWN. 3.PREPARE ALL WORK AS FAR IN ADVANCE AS POSSIBLE TO MINIMIZE SHUTDOWN TIME. 4.ENSURE SUFFICIENT RESOURCES (LABOR, EQUIPMENT, MATERIALS) ARE ON-SITE TO COMPLETE THE WORK IN COMPLIANCE WITH FREDERICK WATER INSPECTOR'S EXPECTATIONS. 5.PREPARE A SHUTDOWN PLAN SATISFACTORY TO THE FREDERICK WATER INSPECTOR. THIS MAY INCLUDE FIRE WATCH, NIGHT WORK, OR OTHER REQUIREMENTS. 6.SCHEDULE THE SHUTDOWN WITH THE FREDERICK WATER INSPECTOR, FREDERICK COUNTY FIRE MARSHAL, AND ALL AFFECTED CUSTOMERS AT LEAST SEVEN (7) DAYS IN ADVANCE, AND MAKE ALL NECESSARY PREPARATIONS AS REQUIRED BY ALL PARTIES. 7.COORDINATE ALL CUT-IN TEE AND VALVES WITH ONE SINGLE SHUT DOWN OF WATER. PROP 5' SIDE W A L KPROP 5' SIDEWALKPROP LIGHT (TYP) PROP FLUSH CURB PROP SIGHT DISTANCE EASEMENT PROP SIGHT DISTANCE EASEMENT N52°33'58" W ( R ) N 5 5 ° 2 0 ' 5 9 " W ( M ) 8 3 9 . 1 1 ' ( R & M ) COSTELL O D R I V E 3 4 - 1 3 6 7 E LOT 1 GARBER ESTATE SUBDIVISION D.B. 838 PG. 1360 LANDS OF THE PRICE COMPANY D.B. 829 PG. 487 TM: 64-8-1 AREA: 13.002 AC. (R&M) OR 566,356 S.F. (M) PROP. SAWCUT LOD LODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTOTAL LIMITS OF DISTURBANCE = 12.85 AC PROP. SAWCUT PROP. SAWCUT W E SNORTH ZONEVCS NAD83 /2011232.7'PROP. SAWCUT LOD LOD LOD PROP ROW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW PROP UNDG SWM SYSTEM #1 ADS STORMTECH CHAMBER SYSTEM STORAGE VOLUME = 32,414 CF STONE BASE = 704.00' BOTTOM OF CHAMBERS = 704.75' TOP OF SYSTEM = 710.95' D D SLSLC/O C/O C/O VARIABLE STORM DRAINAGE EASEMENT VARIABLE STORM DRAINAGE EASEMENT TP TP 24" RCP 30" RCP 30" RCP 15" RCP 18" RCP 24" RCP 24" RCP18" RCP8" HDPE8" HDPE8" HDPE8" HDPE8" HDPE 8" HDPE8" HDPE 8" HDPE8" HDPE8" HDPE 8" HDPEA-111 A-130 A-110 A-120 A-100 A-240 A-220 A-230 BLDG-D BLDG-E BLDG-F BLDG-G CO-4 CO-5 CO-8 CO-9CO-7 CO-6 D-150 D-140 D-130 18" RCP 18" RCP 18" RCP 10+34.94 10+00 SAN-CO-4 SAN-60 C-121.1 BLDG SAN- 4 CONTRACTOR TO OUTLET UD-4 UNDERDRAIN (TYP) PROP UD-4 (TYP) May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-UTIL-NJA220135.00-0A----->LAYOUT: C-504 UTILITY PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-UTIL PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-504 UTILITY PLANMATCHLINE - SHEETC-503MATCHLINE - SHEETC-5051"=20' 0 2051020 UTILITY NOTES: 1.WATER AND SANITARY SEWER LINES LOCATED WITHIN THE EXISTING OR PROPOSED WATER & SEWER EASEMENT ARE OWNED BY FREDERICK WATER OR CITY OF WINCHESTER AS LABELED PER PLAN. 2.SANITARY LATERALS, GREASE TRAPS AND SAND SEPARATOR ARE TO BE OWNED AND MAINTAINED BY COSTCO WHOLESALE. 3.ALL PROPOSED FIRE LINES ARE TO BE RESTRAINED. 4.CONTRACTOR TO PROVIDE TEMPORARY PIPING FOR ALL PROPOSED SERVICE INTERRUPTIONS TO THE EXISTING SANITARY LINE. 5.THE CITY OF WINCHESTER SHALL PROVIDE INSPECTION OF THEIR FACILITIES AS APPLICABLE. 6.UNDERDRAINS (UD-4) HAVE BEEN SPECIFIED BENEATH ALL NEW CURB AND GUTTER SECTIONS WITHIN VDOT ROW. 7.PRIVATELY OWNED SANITARY SEWER INSTALLATIONS OR MODIFICATIONS SHALL BE PERFORMED TO ELIMINATE OR REDUCE INFLOW AND INFILTRATION. CONTRACTOR SHALL REVIEW WORK WITH THE FREDERICK WATER INSPECTOR. 8.IF EXISTING TELEPHONE OR OTHER ENCROACHMENTS ARE MODIFIED BEYOND AS SHOWN ON THESE PLANS THEY SHALL COMPLY WITH CURRENT FREDERICK WATER REQUIREMENTS AND BE COORDINATED WITH THE FREDERICK WATER INSPECTOR FREDERICK WATER NOTES: 1.VALVES, MANHOLES, ARV'S AND OTHER FREDERICK WATER SURFACE FEATURES SHALL NOT BE PLACED IN CURB AND GUTTER, NOR SLOPED PORTION OF HANDICAPPED RAMPS. CONTRACTOR SHALL COORDINATE LOCATIONS WITH THE FREDERICK WATER INSPECTOR. 2.IRRIGATION LINES AND DEVICES, LIGHT POLES, TRANSFORMERS, JUNCTION BOXES, PEDESTALS, OTHER OBSTACLES AND ALL DRY UTILITIES SHALL NOT BE PLACED ON FREDERICK WATER EASEMENTS. PERPENDICULAR IRRIGATION LINES AND DRY UTILITY CROSSINGS ARE PERMITTED WITH 18" MINIMUM VERTICAL SEPARATION. 3.RETAINING WALLS AND THEIR TIE BACKS SUCH AS GEO GRID OR OTHER SUPPORTS SHALL NOT BE PLACED IN FREDERICK WATER EASEMENTS 4.UNDER THE FOLLOWING CIRCUMSTANCES, DEVELOPMENT REQUIRING FIRE HYDRANTS SHALL PROVIDE AT LEAST ONE KENNEDY IHYDRANT OR MUELLER SUPER CENTURION WITH HYDRO-GUARD FOR REMOTE PRESSURE AND TEMPERATURE MONITORING. THE DEVELOPER OR HIS/HER AGENT SHALL PROCURE A TWO-YEAR MONITORING CONTRACT FOR THE MONITORING SERVICE AND TELEMETRY AND PROVIDE ACCESS TO FREDERICK WATER ONCE THE SUBSCRIPTION IS ACTIVE. THE FREDERICK WATER INSPECTOR SHALL CHOOSE WHICH OF THE REQUIRED HYDRANTS SHALL BE A KENNEDY IHYDRANT OR MUELLER SUPER CENTURION. 1. EACH RESIDENTIAL SITE PLAN (EACH INDEPENDENTLY SUBMITTED SECTION AND/OR PHASE) 2. ANY COMMERCIAL OR INDUSTRIAL SITE PLAN WHICH HAS THREE (3) OR MORE FIRE HYDRANTS GREASE TRAP / OIL WATER SEPARATOR / SAND SEPARATOR NOTES: 1.TANK SECTIONS SHALL BE BOLTED TOGETHER. 2.WATERTIGHT BOLT DOWN FRAME AND COVERS ARE REQUIRED. 3.PENETRATIONS SHALL HAVE BOOTS. 4.TANK, COMPONENTS, AND INSTALLATIONS SHALL BE TRAFFIC RATED. 5.CONTRACTOR SHALL COORDINATE INSTALLATION AND INSPECTIONS WITH BOTH FREDERICK COUNTY INSPECTIONS DEPARTMENT AND FREDERICK WATER WATER MAIN CONNECTION NOTES CONTRACTOR SHALL: 1.TEST PIT THE EXISTING MAINS IN ACCORDANCE WITH FREDERICK WATER INSPECTOR'S REQUIREMENTS. 2.INSTALL JOINT RESTRAINTS ON EXISTING MAINS PER CURRENT FREDERICK WATER STANDARDS PRIOR TO SHUTDOWN. 3.PREPARE ALL WORK AS FAR IN ADVANCE AS POSSIBLE TO MINIMIZE SHUTDOWN TIME. 4.ENSURE SUFFICIENT RESOURCES (LABOR, EQUIPMENT, MATERIALS) ARE ON-SITE TO COMPLETE THE WORK IN COMPLIANCE WITH FREDERICK WATER INSPECTOR'S EXPECTATIONS. 5.PREPARE A SHUTDOWN PLAN SATISFACTORY TO THE FREDERICK WATER INSPECTOR. THIS MAY INCLUDE FIRE WATCH, NIGHT WORK, OR OTHER REQUIREMENTS. 6.SCHEDULE THE SHUTDOWN WITH THE FREDERICK WATER INSPECTOR, FREDERICK COUNTY FIRE MARSHAL, AND ALL AFFECTED CUSTOMERS AT LEAST SEVEN (7) DAYS IN ADVANCE, AND MAKE ALL NECESSARY PREPARATIONS AS REQUIRED BY ALL PARTIES. 7.COORDINATE ALL CUT-IN TEE AND VALVES WITH ONE SINGLE SHUT DOWN OF WATER. PROP FLUSH CURB PROP SIGHT DISTANCE EASEMENT PROP SIGHT DISTANCE EASEMENT COST E L L O D R I V E 3 4 - 1 3 6 7 ES22°42'25"W (R) S19°55'24"W (M) 458.80' (R&M)PROP. SAWCUTLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP. SAWCUT R=460.00' (R&M) Δ=031°52'40" (R&M) L=255.93' (R&M) CHB=S68°30'18"E (R) CHB=N71°17'19"W (M) CHD=252.64' (R&M) R=1040.00' (R&M) Δ=008°18'13" (R&M) L=150.72' (R&M) CHB=N80°17'31"W (R) CHB=N83°04'32"W (M) CHD=150.59' (R&M) N84°26'38"W (R) N87°13'39"W (M) 129.72' (R&M) W E SNORTH ZONEVCS NAD83 /2011 PROP ROW PROP ROW LOWLOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOWTOTAL LIMITS OF DISTURBANCE = 12.85 AC WWWWWWWWWWWPROP DROP CONNECTION (RIM TO BE ADJUSTED) S SSSSSSPROP GREASE TRAP PROP 8" CL 52 WATERLINEPROP TELEPROP UNDG SWM SYSTEM #3 STORMTRAP OR APPROVED EQUAL STORAGE VOLUME = 49,571 CF STONE BASE = 697.25 BOTTOM OF CHAMBER = 699.00' TOP OF CHAMBER = 704.00' D PROP TRENCH DRAIN D D D D DSLSL SPROP UNDG SWM SYSTEM #2 ADS STORMTECH CHAMBER SYSTEM STORAGE VOLUME = 25,250 CF STONE BASE = 703.16' BOTTOM OF CHAMBERS = 703.91' TOP OF SYSTEM = 709.91' C/O C/O C/O VARIABLE STORM DRAINAGE EASEMENT 20' STORM DRAINAGE EASEMENTTP TP TP PROP 8" X 8" TEE (3) 8" GATE VALVES INV A = 707.00 PROP 8" PVC PROP 8" PVCD D TTTTTTTTTTPROP 8" CL 52 WATERLINE PROP HYDRANT #2 TP EXTENT OF FREDERICK WATER COMBINED WATER AND SEWER EASEMENT. SEWER BEYOND THIS EASEMENT IS PRIVATELY OWNED AND MAINTAINED. W D D D 12" HDPE 12" HD P E 24" RCP36" RCP 36" RCP 3 6 " R C P 36" RCP 36" RCP8" HDPE8" HDPE 8" HDPE 8" HDPEB-140 A-200 A-210 B-120 D-220 D-210 B-110 B-100 EX-5 BLDG-I BLDG-H CO-11 CO-10 B-150 C-111 C-110 C-121.2 C-112A C-100 C-120 B-131 C-122 C-210 D-130 C-220C-230 D-120 B-111 D-110 EX-6 30" RCP18" RCP 12" RCP 12" HDPE 12" HDPE 12" HDP E 24" RCP 15" HD P E 30" RCP18" RCP 18" RCP 36" RCP30" RCP36" RCP 36" RC P 10+00 11+0010+5010+00 11+0010+5011+5010+16.80 10+00 10+34.94 10+00 CONTRACTOR TO CONNECT TO EXISTING 8" WATERLINE. COORDINATE FIELD CONNECTION WITH FREDERICK WATER. SAN-CO-6 SAN-CO-5 SAN-CO-4 SAN-60 SAN-30 SAN-10 D-120 D-100 B-112 C-121 B-101 PROP 12" HDPE B-130 12" H D P E C-211 C-121.1 BLDG SAN- 4 CONTRACTOR TO OUTLET UD-4 UNDERDRAIN (TYP) PROP UD-4 (TYP) May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-UTIL-NJA220135.00-0A----->LAYOUT: C-505 UTILITY PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-UTIL PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-505 UTILITY PLAN MATCHLINE - SHEET C-506 MATCHLINE - SHEETC-5041"=20' 0 2051020 UTILITY NOTES: 1.WATER AND SANITARY SEWER LINES LOCATED WITHIN THE EXISTING OR PROPOSED WATER & SEWER EASEMENT ARE OWNED BY FREDERICK WATER OR CITY OF WINCHESTER AS LABELED PER PLAN. 2.SANITARY LATERALS, GREASE TRAPS AND SAND SEPARATOR ARE TO BE OWNED AND MAINTAINED BY COSTCO WHOLESALE. 3.ALL PROPOSED FIRE LINES ARE TO BE RESTRAINED. 4.CONTRACTOR TO PROVIDE TEMPORARY PIPING FOR ALL PROPOSED SERVICE INTERRUPTIONS TO THE EXISTING SANITARY LINE. 5.THE CITY OF WINCHESTER SHALL PROVIDE INSPECTION OF THEIR FACILITIES AS APPLICABLE. 6.UNDERDRAINS (UD-4) HAVE BEEN SPECIFIED BENEATH ALL NEW CURB AND GUTTER SECTIONS WITHIN VDOT ROW. 7.PRIVATELY OWNED SANITARY SEWER INSTALLATIONS OR MODIFICATIONS SHALL BE PERFORMED TO ELIMINATE OR REDUCE INFLOW AND INFILTRATION. CONTRACTOR SHALL REVIEW WORK WITH THE FREDERICK WATER INSPECTOR. 8.IF EXISTING TELEPHONE OR OTHER ENCROACHMENTS ARE MODIFIED BEYOND AS SHOWN ON THESE PLANS THEY SHALL COMPLY WITH CURRENT FREDERICK WATER REQUIREMENTS AND BE COORDINATED WITH THE FREDERICK WATER INSPECTOR FREDERICK WATER NOTES: 1.VALVES, MANHOLES, ARV'S AND OTHER FREDERICK WATER SURFACE FEATURES SHALL NOT BE PLACED IN CURB AND GUTTER, NOR SLOPED PORTION OF HANDICAPPED RAMPS. CONTRACTOR SHALL COORDINATE LOCATIONS WITH THE FREDERICK WATER INSPECTOR. 2.IRRIGATION LINES AND DEVICES, LIGHT POLES, TRANSFORMERS, JUNCTION BOXES, PEDESTALS, OTHER OBSTACLES AND ALL DRY UTILITIES SHALL NOT BE PLACED ON FREDERICK WATER EASEMENTS. PERPENDICULAR IRRIGATION LINES AND DRY UTILITY CROSSINGS ARE PERMITTED WITH 18" MINIMUM VERTICAL SEPARATION. 3.RETAINING WALLS AND THEIR TIE BACKS SUCH AS GEO GRID OR OTHER SUPPORTS SHALL NOT BE PLACED IN FREDERICK WATER EASEMENTS 4.UNDER THE FOLLOWING CIRCUMSTANCES, DEVELOPMENT REQUIRING FIRE HYDRANTS SHALL PROVIDE AT LEAST ONE KENNEDY IHYDRANT OR MUELLER SUPER CENTURION WITH HYDRO-GUARD FOR REMOTE PRESSURE AND TEMPERATURE MONITORING. THE DEVELOPER OR HIS/HER AGENT SHALL PROCURE A TWO-YEAR MONITORING CONTRACT FOR THE MONITORING SERVICE AND TELEMETRY AND PROVIDE ACCESS TO FREDERICK WATER ONCE THE SUBSCRIPTION IS ACTIVE. THE FREDERICK WATER INSPECTOR SHALL CHOOSE WHICH OF THE REQUIRED HYDRANTS SHALL BE A KENNEDY IHYDRANT OR MUELLER SUPER CENTURION. 1. EACH RESIDENTIAL SITE PLAN (EACH INDEPENDENTLY SUBMITTED SECTION AND/OR PHASE) 2. ANY COMMERCIAL OR INDUSTRIAL SITE PLAN WHICH HAS THREE (3) OR MORE FIRE HYDRANTS GREASE TRAP / OIL WATER SEPARATOR / SAND SEPARATOR NOTES: 1.TANK SECTIONS SHALL BE BOLTED TOGETHER. 2.WATERTIGHT BOLT DOWN FRAME AND COVERS ARE REQUIRED. 3.PENETRATIONS SHALL HAVE BOOTS. 4.TANK, COMPONENTS, AND INSTALLATIONS SHALL BE TRAFFIC RATED. 5.CONTRACTOR SHALL COORDINATE INSTALLATION AND INSPECTIONS WITH BOTH FREDERICK COUNTY INSPECTIONS DEPARTMENT AND FREDERICK WATER WATER MAIN CONNECTION NOTES CONTRACTOR SHALL: 1.TEST PIT THE EXISTING MAINS IN ACCORDANCE WITH FREDERICK WATER INSPECTOR'S REQUIREMENTS. 2.INSTALL JOINT RESTRAINTS ON EXISTING MAINS PER CURRENT FREDERICK WATER STANDARDS PRIOR TO SHUTDOWN. 3.PREPARE ALL WORK AS FAR IN ADVANCE AS POSSIBLE TO MINIMIZE SHUTDOWN TIME. 4.ENSURE SUFFICIENT RESOURCES (LABOR, EQUIPMENT, MATERIALS) ARE ON-SITE TO COMPLETE THE WORK IN COMPLIANCE WITH FREDERICK WATER INSPECTOR'S EXPECTATIONS. 5.PREPARE A SHUTDOWN PLAN SATISFACTORY TO THE FREDERICK WATER INSPECTOR. THIS MAY INCLUDE FIRE WATCH, NIGHT WORK, OR OTHER REQUIREMENTS. 6.SCHEDULE THE SHUTDOWN WITH THE FREDERICK WATER INSPECTOR, FREDERICK COUNTY FIRE MARSHAL, AND ALL AFFECTED CUSTOMERS AT LEAST SEVEN (7) DAYS IN ADVANCE, AND MAKE ALL NECESSARY PREPARATIONS AS REQUIRED BY ALL PARTIES. 7.COORDINATE ALL CUT-IN TEE AND VALVES WITH ONE SINGLE SHUT DOWN OF WATER. PROP GAS ATTENDANT BUILDING 84.3' PROP FUEL CANOPY WITH 32 FUELING POSITIONS HEIGHT = 19.5' PROP BUILDING EXPANSION FOOTPRINT AREA=20,709 SF FFE = 719.28 HEIGHT = 30.5' PROP FOUR (4) BAYS T PROP TRANSFORMER PROP MASONRY SCREENING WALL FOR TRASH COMPACTORS 20' FREDERICK WATER EASEMENT FOR FUTURE WATERMAIN EXTENSION (TYP) PROP TRANSFORMER PROP BATHROOM FOR ATTENDANT 59.2'LOT 1 GARBER ESTATE SUBDIVISION D.B. 838 PG. 1360 LANDS OF THE PRICE COMPANY D.B. 829 PG. 487 TM: 64-8-1 AREA: 13.002 AC. (R&M) OR 566,356 S.F. (M) ZONING: B2 S60°23'46"E (R) S63°10'47"E (M) 852.51' (R&M)S23°22'33"W (R)S20°35'32"W (M)82.25' (R&M)S22°42'25"W (R) S19°55'24"W (M) 458.80' (R&M)PROP. SAWCUT TOTAL LIMITS OF DISTURBANCE = 12.85 AC LODLODLODLODLODLODLODLOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011 EX FDC (TO REMAIN)59.3'D SSPROP SHUTOFF VALVE WWWWWWWWWWWWWWWWWWWWWWWWPROP CL 52 8" WATERLINEPROP 8" PVCPROP TELESSPROP 8" CL 52 WATERLINEPROP TRENCH DRAIN SL SL SL SSSSSSSSSSSSSSSS 20' FREDERICK WATER EASEMENT (TYP) 20' FREDERICK WATER EASEMENT PROP HYDRANT #1 PROP 8" CL 52 WATERLINETP PROP 8" X 8" TEE (3) 8" GATE VALVES PROP 8" PVCDTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT T T E E EEEEEEEEEEEEEEEE E EEEEEEEEEEEEEE DD PROP OIL/WATER SEPARATOR PROP HYDRANT #3 (DEDICATED TO FDC) TP PROP 8" X 8" TEE (3) 8" GATE VALVES PROP 8" CL 52 WATERLINE 33.7'SL PROP SAND SEPARATOR D D 10' 10' PROP 8" PVC TP WWPROP 6"CL 52 FIRELINE PROP HP PROTECTUS 2 STAINLESS STEEL METER INTERNAL TO BUILDING PROP 8" X 6" TEE (1) 6" GATE VALVE 20' FREDERICK WATER EASEMENT 8" HDPE 8" HDPE 8" HDPE8" HDPE 8" HDPE8" HDPE 8" HDPE 8" HDPE8" HDPE8" HDPE 8" HDPE 8" HDPE 8" HDPE 8" HDPE 8" HDPE 8" HDPE 8" HDPEBLDG-J BLDG-O CO-19 CO-12 CO-18 BLDG-L BLDG-M BLDG-K CO-15 BLDG-N CO-17 CO-13 CO-14 CO-16 BLDG-I BLDG-H CO-11 C-160 C-113 C-111 C-110 WYE-9 WYE-5 WYE-8 WYE-4 WYE-7 WYE-2 WYE-6 CO-22 WYE-1 CO-21 C-141 C-141A C-143 CNPY-L C-112A CNPY-H CNPY-K CNPY-G CNPY-F CNPY-J CNPY-E CNPY-D CNPY-I CNPY-C C-130 CNPY-B CNPY-A C-1206" HDPE6" HDPE6" HDPE6" HDPE 4" HDPE4" HDPE4" HDPE6" HDPE4" HDPE6" HDPE 6" HDPE6" HDPE6" HDPE 4" HDPE 4" HDPE4" HDPE 4" HDPE4" HDPE4" HDPE4" HDPE4" HDPE30" RCP18" RCP15" RCP 12" HDPE 18" RCP12" RCP12" RCP 15" HDPE 24" RCP 8" HDPE 13+71.01 11+0012+0013+0011+5012+5013+5014+57.96 12+0013+001 4 + 0 0 11+5012+50 13+501 4 + 5 0 10+10.41 10+00 10+47.75 10+00 SAN-CO-1 SAN-CO-2 SAN-CO-3 SAN-40 SAN-50 SAN-30 BEND-1 6" HDPE 4" HDPE C-142 C-150 PROP 15" HDPEPROP 15" HDPEWYE-14 WYE-15 PROP 4" HDPE PROP 4" HDPE BEND-2 DS-1 DS-2 8" HDPE BLDG SAN - 2 BLDG SAN - 3 BLDG SAN - 1 SAN-45 PROP INSERTA TEE EXISTING FIRE LINE TO BUILDING TO REMAIN OPERATIONAL UNTIL PROPOSED FIRE LINE AND PUMP IS OPERATION. COORDINATE REMOVAL OF EXISTING FIRE LINE WITH FREDERICK WATER . May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-UTIL-NJA220135.00-0A----->LAYOUT: C-506 UTILITY PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-UTIL PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-506 UTILITY PLAN MATCHLINE - SHEET C-505 1"=20' 0 2051020 UTILITY NOTES: 1.WATER AND SANITARY SEWER LINES LOCATED WITHIN THE EXISTING OR PROPOSED WATER & SEWER EASEMENT ARE OWNED BY FREDERICK WATER OR CITY OF WINCHESTER AS LABELED PER PLAN. 2.SANITARY LATERALS, GREASE TRAPS AND SAND SEPARATOR ARE TO BE OWNED AND MAINTAINED BY COSTCO WHOLESALE. 3.ALL PROPOSED FIRE LINES ARE TO BE RESTRAINED. 4.CONTRACTOR TO PROVIDE TEMPORARY PIPING FOR ALL PROPOSED SERVICE INTERRUPTIONS TO THE EXISTING SANITARY LINE. 5.THE CITY OF WINCHESTER SHALL PROVIDE INSPECTION OF THEIR FACILITIES AS APPLICABLE. 6.UNDERDRAINS (UD-4) HAVE BEEN SPECIFIED BENEATH ALL NEW CURB AND GUTTER SECTIONS WITHIN VDOT ROW. 7.PRIVATELY OWNED SANITARY SEWER INSTALLATIONS OR MODIFICATIONS SHALL BE PERFORMED TO ELIMINATE OR REDUCE INFLOW AND INFILTRATION. CONTRACTOR SHALL REVIEW WORK WITH THE FREDERICK WATER INSPECTOR. 8.IF EXISTING TELEPHONE OR OTHER ENCROACHMENTS ARE MODIFIED BEYOND AS SHOWN ON THESE PLANS THEY SHALL COMPLY WITH CURRENT FREDERICK WATER REQUIREMENTS AND BE COORDINATED WITH THE FREDERICK WATER INSPECTOR FREDERICK WATER NOTES: 1.VALVES, MANHOLES, ARV'S AND OTHER FREDERICK WATER SURFACE FEATURES SHALL NOT BE PLACED IN CURB AND GUTTER, NOR SLOPED PORTION OF HANDICAPPED RAMPS. CONTRACTOR SHALL COORDINATE LOCATIONS WITH THE FREDERICK WATER INSPECTOR. 2.IRRIGATION LINES AND DEVICES, LIGHT POLES, TRANSFORMERS, JUNCTION BOXES, PEDESTALS, OTHER OBSTACLES AND ALL DRY UTILITIES SHALL NOT BE PLACED ON FREDERICK WATER EASEMENTS. PERPENDICULAR IRRIGATION LINES AND DRY UTILITY CROSSINGS ARE PERMITTED WITH 18" MINIMUM VERTICAL SEPARATION. 3.RETAINING WALLS AND THEIR TIE BACKS SUCH AS GEO GRID OR OTHER SUPPORTS SHALL NOT BE PLACED IN FREDERICK WATER EASEMENTS 4.UNDER THE FOLLOWING CIRCUMSTANCES, DEVELOPMENT REQUIRING FIRE HYDRANTS SHALL PROVIDE AT LEAST ONE KENNEDY IHYDRANT OR MUELLER SUPER CENTURION WITH HYDRO-GUARD FOR REMOTE PRESSURE AND TEMPERATURE MONITORING. THE DEVELOPER OR HIS/HER AGENT SHALL PROCURE A TWO-YEAR MONITORING CONTRACT FOR THE MONITORING SERVICE AND TELEMETRY AND PROVIDE ACCESS TO FREDERICK WATER ONCE THE SUBSCRIPTION IS ACTIVE. THE FREDERICK WATER INSPECTOR SHALL CHOOSE WHICH OF THE REQUIRED HYDRANTS SHALL BE A KENNEDY IHYDRANT OR MUELLER SUPER CENTURION. 1. EACH RESIDENTIAL SITE PLAN (EACH INDEPENDENTLY SUBMITTED SECTION AND/OR PHASE) 2. ANY COMMERCIAL OR INDUSTRIAL SITE PLAN WHICH HAS THREE (3) OR MORE FIRE HYDRANTS GREASE TRAP / OIL WATER SEPARATOR / SAND SEPARATOR NOTES: 1.TANK SECTIONS SHALL BE BOLTED TOGETHER. 2.WATERTIGHT BOLT DOWN FRAME AND COVERS ARE REQUIRED. 3.PENETRATIONS SHALL HAVE BOOTS. 4.TANK, COMPONENTS, AND INSTALLATIONS SHALL BE TRAFFIC RATED. 5.CONTRACTOR SHALL COORDINATE INSTALLATION AND INSPECTIONS WITH BOTH FREDERICK COUNTY INSPECTIONS DEPARTMENT AND FREDERICK WATER WATER MAIN CONNECTION NOTES CONTRACTOR SHALL: 1.TEST PIT THE EXISTING MAINS IN ACCORDANCE WITH FREDERICK WATER INSPECTOR'S REQUIREMENTS. 2.INSTALL JOINT RESTRAINTS ON EXISTING MAINS PER CURRENT FREDERICK WATER STANDARDS PRIOR TO SHUTDOWN. 3.PREPARE ALL WORK AS FAR IN ADVANCE AS POSSIBLE TO MINIMIZE SHUTDOWN TIME. 4.ENSURE SUFFICIENT RESOURCES (LABOR, EQUIPMENT, MATERIALS) ARE ON-SITE TO COMPLETE THE WORK IN COMPLIANCE WITH FREDERICK WATER INSPECTOR'S EXPECTATIONS. 5.PREPARE A SHUTDOWN PLAN SATISFACTORY TO THE FREDERICK WATER INSPECTOR. THIS MAY INCLUDE FIRE WATCH, NIGHT WORK, OR OTHER REQUIREMENTS. 6.SCHEDULE THE SHUTDOWN WITH THE FREDERICK WATER INSPECTOR, FREDERICK COUNTY FIRE MARSHAL, AND ALL AFFECTED CUSTOMERS AT LEAST SEVEN (7) DAYS IN ADVANCE, AND MAKE ALL NECESSARY PREPARATIONS AS REQUIRED BY ALL PARTIES. 7.COORDINATE ALL CUT-IN TEE AND VALVES WITH ONE SINGLE SHUT DOWN OF WATER. DATUM ELEV700.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED SANITARY MAIN PROFILE7057107157207257057107157207259+5010+0010+5011+0011+5012+0012+5013+0013+5014+0014+50SAN-CO-1 PROP SAN CO RIM 719.10 INV IN 714.40 (8") A-350 INV OUT 714.20 (8") SAN-50 13+65.01 SAN-50 PROP SAN MH RIM 718.72 INV IN 713.20 (8") SAN-CO-1 INV OUT 713.00 (8") SAN-45 13+51.89 SAN-30 PROP SAN MH RIM 717.50 INV IN 709.15 (8") SAN-40 INV OUT 708.95 (8") SAN-10 11+17.99 SAN-10PROP SAN MHRIM 716.30INV IN 707.60 (8") SAN-30INV OUT 707.40 (8")10+26.75 PROP 13 LF 8" PVC @ 7.62%PROP 141 LF 8" PVC @ 1.64%PROP 91 LF 8" PVC @ 1.48%PROP 27 LF 8" PVC @ 1.51%PROP GRADEPROP BUILDINGFFE = 719.2811+31 PROP 12" STM X-ING 11+99 PROP 8" STM X-ING 12+46 PROP 8" STM X-ING 7.1' COVER PROP DROP MANHOLE CONNECTIONINV IN 707.00 (8")(RIM TO BE RESET AT 716.19) 13+62.69 PROP STM X-ING 13+74.58 PROP BLDG CONNECTION PROP 6 LF 8" PVC @ 6.33%SAN-40 PROP SAN MH RIM 718.53 INV IN 710.07 (8") SAN-45 INV IN 710.07 (6") A-310 INV OUT 709.87 (8") SAN-30 11+73.87 2.9' CLEAR 0.9' CLEAR 7.8' COVER 3.8' COVER 8.0' CLEAR 3.9' CLEAR 10+21PROP TELE 12+20 PROP ELEC 13+58 PROP TELE 13+60 PROP ELEC SAN-45 PROP SAN MH RIM 718.25 INV IN 710.68 (8") SAN-50 INV OUT 710.48 (8") SAN-40 12+10.65 PROP 56 LF 8" PVC @ 1.29%PROP 37 LF 8" PVC @ 1.12%1.7' CLEAR 0SCALE:1" = 20'2020510C-601SANITARYPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSAN-NJA220135.00-0A----->LAYOUT: C-601 PSANYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSANPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026EXISTING GRADEPROFILEPROPOSED GRADECOMPACTED FILLUTILITY NOTES:1.RESTRAINED JOINTS TO BELOCATED IN FILL AREAS AND 20'ONTO ORIGINAL GROUND.2.ALL SANITARY SEWER SHOWN INPROFILE IS PRIVATELY OWNEDAND MAINTAINED. DATUM ELEV700.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED SANITARY PROFILE (SAN-60 - BLDG)7057107157207057107157209+5010+0010+5011+00PROP GRADE6.2' COVERPROP 16 LF 6" PVC @ 12.50%SAN-60 PROP SAN MH RIM 717.49 INV IN 708.88 (6") SAN-CO-4 10+00 SAN-CO-4 PROP SAN MH RIM 717.87 INV IN 710.93 (6") SAN-GI-1 INV OUT 710.93 (6") SAN-60 10+16.40 PROP 2 LF 6" PVC @ 12.40%SAN-CO-5 PROP SAN MH RIM 718.71 INV IN 711.61 (6") SAN-CO-6 INV OUT 711.61 (6") SAN-GI-2 10+31.64 SAN-CO-6 PROP SAN MH RIM 718.73 INV IN 711.74 (6") BLDG INV OUT 711.74 (6") SAN-CO-5 10+32.64 PROP 2 LF 6" PVC @ 9.15%PROP 1 LF 6" PVC @ 13.00%PROP BUILDINGFFE = 719.28GREASE INTERCEPTORSEE DETAIL ON SHEET C-10036.7' COVER 10+34.94 PROP BLDG CONNECTION DATUM ELEV705.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED SANITARY PROFILE (SAN-40 - BLDG)7107157207257107157207259+5010+0010+5011+003.4' COVER PROP 10 LF 6" PVC @ 7.61%SAN-CO-3 PROP SAN CO RIM 718.76 INV IN 713.00 (6") BLDG INV OUT 713.00 (6") SAN-SS-2 10+33.28 PROP 14 LF 6" PVC @ 8.85%PROP GRADEPROP BUILDINGFFE = 719.284.2' COVER 10+49.28 PROP BLDG CONNECTION SAND SEPARATORSEE DETAIL ON SHEET C-1003PROP 5 LF 6" PVC @ 10.24%PROP 10 LF 6" PVC @ 11.09%10+00 PROP SAN X-ING INV 710.68DATUM ELEV705.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED SANITARY PROFILE (BLDG SAN - 3 - SAN-40)7107157207257107157207259+5010+0010+5011+00PROP BUILDINGFFE = 719.282.7' CLEAR 5.2' COVER PROP GRADE10+37.45PROP BLDG CONNECTION10+33.41PROP STM X-INGSAN-40PROP SAN MHRIM 718.53INV IN 710.07 (8") SAN-45INV IN 710.07 (6") A-310INV OUT 709.87 (8") SAN-3010+00 PROP 37 LF 6" PVC @ 9.16%0SCALE:1" = 20'2020510C-602SANITARYPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSAN-NJA220135.00-0A----->LAYOUT: C-602 PSANYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSANPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026EXISTING GRADEPROFILEPROPOSED GRADECOMPACTED FILLUTILITY NOTES:1.RESTRAINED JOINTS TO BELOCATED IN FILL AREAS AND 20'ONTO ORIGINAL GROUND.2.ALL SANITARY SEWER SHOWN INPROFILE IS PRIVATELY OWNEDAND MAINTAINED. DATUM ELEV705.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED WATER MAIN PROFILE7107157207257107157207259+5010+0010+5011+0011+5012+0012+5013+0013+5014+0014+5015+0015+504.1' COVER PROP GRADEPROP 54.54 LF 8" CL 52 DIPPROP 5.61 LF 8" CL 52 DIP13+96.35 PROP 45° HORIZ BEND 10+00 PROP CONNECTION BY CONTRACTOR 14+51.77 PROP 8" X 8" TEE = 10+00 HYDRANT 1 PROFILE 11+59 PROP 12" STM X-ING 12+27 PROP 8" STM X-ING 12+75 PROP 8" STM X-ING 14+69.22 PROP CONNECTION BY CONTRACTOR (3) 8" GATE VALVES PROP 24.50 LF 8" CL 52 PVC10+35.36 PROP 60° HORIZ BEND10+60.79 PROP 8" X 8" TEE10+84.13 PROP 22.50° HORIZ BEND(3) 8" GATE VALVES PROP 34.78 LF 8" CL 52 DIPPROP 45° BEND 4.0' COVER 1.5' CLEAR 1.6' CLEAR (2) MJ LONG SOLID SLEEVES REQUIRED 14+19 PROP ELEC 14+16 PROP TELE 12+47 PROP ELEC 1.6' CLEAR 1.6' CLEAR PROP 45° BEND (2) MJ LONG SOLID SLEEVES REQUIRED PROP 118.37 LF 8'' CL 52 DIP2.4' CLEAR 4.3' COVER PROP 10.51 LF 8'' CL 52 DIPPROP 108.35 LF 8'' CL 52 DIP0.5' CLEAR PROP 62.20 LF 8'' CL 52 DIP4.3' COVERPROP 22.47 LF 8" CL 52 DIPPROP 12.20 LF 8" CL 52 DIPSEE UTILITY NOTE #2BELOWPROP COMPACTED FILL0SCALE:1" = 20'2020510C-603WATERPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PWAT-NJA220135.00-0A----->LAYOUT: C-603 PWATYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PWATPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026EXISTING GRADEPROFILEPROPOSED GRADECOMPACTED FILLUTILITY NOTES:1.RESTRAINED JOINTS REQUIRED INFILL MIN. 20' ONTO ORIGINALGROUND.2.CONCRETE ARCH REQUIRED OVERSTORM CROSSING WITH REDUCEDCLEARANCE. DATUM ELEV705.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED HYDRANT 2 PROFILE7107157207257107157207259+5010+0010+5011+00PROP GRADE(3) 8" GATE VALVES 10+17 PROP FIRE HYDRANT 2 10+60.79 PROP 8" X 8" TEE 4.0' COVER (1) 8" GATE VALVE PROP 15.92 LF 8" CL 52 DIPPROP COMPACTED FILLDATUM ELEV705.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED HYDRANT 1 PROFILE7107157207257107157207259+5010+0010+5011+0010+00 PROP 8" X 8" TEE = 14+63.02 WATER MAIN PROFILE PROP GRADE(3) 8" GATE VALVES 10+10 PROP FIRE HYDRANT 1 4.0' COVER PROP 9.54 LF 8" CL 52 DIP0SCALE:1" = 20'2020510C-604WATERPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PWAT-NJA220135.00-0A----->LAYOUT: C-604 PWATYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PWATPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026EXISTING GRADEPROFILEPROPOSED GRADECOMPACTED FILLUTILITY NOTES:1.RESTRAINED JOINTS REQUIRED INFILL MIN. 20' ONTO ORIGINALGROUND.2.CONCRETE ARCH REQUIRED OVERSTORM CROSSING WITH REDUCEDCLEARANCE. DATUM ELEV700.007057107157209+5010+0010+5011+0011+5012+0012+5013+0013+5014+0014+5015+00A-10010+00PROP MHRIM 715.31INV IN 706.45 (30") A-110 PROP 218 LF 30" RCP @ 0.76%A-110 12+18.44 PROP MH RIM 716.33 INV IN 708.10 (30") A-120 INV IN 711.15 (18") A-111 INV OUT 708.10 (30") A-100 PROP 155 LF 30" RCP @ 0.52%A-120 13+73.47 PROP CURB INLET RIM 715.74 INV IN 709.40 (24") A-130 INV IN 712.20 (15") A-121 INV OUT 708.90 (30") A-110 PROP 73 LF 24" RCP @ 0.95%A-130 14+46.39 PROP CURB INLET RIM 715.92 INV IN 711.40 (15") A-131 INV IN 710.10 (24") A-140 INV OUT 710.10 (24") A-120 5.3' COVER4' COVERPROP GRADEPROP UNDERGROUND DETENTIONSYSTEM #1.SEE SHEET C-911 - C-912 FOR DETAILS10 YR HGLPROP 207 LF 24" RCP @ 0.53%3.6' COVERSCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (A-100 - A-190)DATUM ELEV705.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (A-130 - A-133)7107157207107157209+5010+0010+5011+0011+5012+0012+50A-13010+00PROP CURB INLETRIM 715.92INV IN 711.40 (15") A-131INV IN 710.10 (24") A-140INV OUT 710.10 (24") A-120 A-133 12+12.96 PROP CURB INLET RIM 719.01 INV OUT 715.33 (12") A-132 PROP 89 LF 12" HDPE @ 1.50%A-13211+24.25PROP CURB INLETRIM 717.72INV IN 714.00 (12") A-133INV OUT 714.00 (12") A-131 PROP 83 LF 12" HDPE @ 1.52%A-13110+41.75PROP CURB INLETRIM 716.16INV IN 712.75 (12") A-132INV OUT 712.50 (15") A-130 PROP 42 LF 15" RCP @ 2.64%2.3' COVER 2.6' COVER PROP GRADE10 YR HGL2.2' COVER DATUM ELEV700.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (B-130 - B-131)7057107157057107159+5010+0010+5011+00B-131 10+39.36 PROP MH RIM 713.82 INV OUT 703.16 (30") 7.9' COVER PROP GRADE10 YR HGL10+11 PROP 12" STM X-ING B-130 10+00 PROP MH RIM 713.75 INV IN 703.00 (36") B-140 INV OUT 702.90 (36") B-120 0SCALE:1" = 20'2020510C-605STORMPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-605 PSTMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - STATION 15+00EXISTING GRADEPROFILEPROPOSED GRADEHYDRAULIC GRADE LINECOMPACTED FILL 70571071572015+0015+5016+0016+5017+0017+5018+0018+50PROP 207 LF 24" RCP @ 0.53%A-14016+53.55PROP CURB INLET RIM 717.44 INV IN 711.69 (18") A-150 INV OUT 711.20 (24") A-130 PROP 93 LF 18" RCP @ 0.50%A-150 17+46.62 PROP CURB INLET RIM 718.35 INV IN 712.16 (24") A-190 INV IN 712.16 (8") CO-1 INV OUT 712.16 (18") A-140 PROP GRADE10 YR HGLPROP 207 LF 24" RCP @ 0.53%3.6' COVERSCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (A-100 - A-190)DATUM ELEV705.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (A-110 - A111)7107157207107157209+5010+0010+5011+0011+5012+00A-11010+00PROP MHRIM 716.33INV IN 708.10 (30") A-120INV IN 711.15 (18") A-111INV OUT 708.10 (30") A-100 A-111 11+43.86 PROP MH RIM 718.93 INV IN 713.90 (8") CO-7 INV IN 713.90 (8") CO-8 INV OUT 713.07 (18") A-110 PROP 144 LF 18" RCP @ 1.33%PROP GRADE11+39 EX 8" SAN X-ING INV 710.63 1.5' CLEAR 10 YR HGL4.1' COVER DATUM ELEV690.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (B-100 - B-101)6957007057106957007057109+5010+0010+5011+00PROP GRADEB-100 10+00 PROP MH RIM 703.41 INV IN 697.50 (36") B-110 INV IN 698.80 (12") B-101 INV OUT 697.40 (36") EX-5 10 YR HGLPROP 47 LF 12" HDPE @ 2.53%B-101 10+47.36 PROP CURB INLET RIM 706.95 INV OUT 700.00 (12") B-100 3.5' COVER 0SCALE:1" = 20'2020510C-606STORMPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-606 PSTMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - STATION 15+00 EXISTING GRADEPROFILEPROPOSED GRADEHYDRAULIC GRADE LINECOMPACTED FILL DATUM ELEV705.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (A-120 - A-122)7107157207107157209+5010+0010+5011+0011+5012+0012+5013+00A-120 10+00 PROP CURB INLET RIM 715.74 INV IN 709.40 (24") A-130 INV IN 712.20 (15") A-121 INV OUT 708.90 (30") A-110 A-121 11+02.13 PROP CURB INLET RIM 717.19 INV IN 713.73 (15") A-122 INV OUT 713.73 (15") A-120 PROP 110 LF 15" RCP @ 1.50%PROP 102 LF 15" RCP @ 1.50%A-122 12+12.13 PROP CURB INLET RIM 718.78 INV OUT 715.38 (15") A-121 2.2' COVERPROP GRADE10 YR HGL2.0' COVER DATUM ELEV700.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (A-200 - A-240)7057107157207057107157209+5010+0010+5011+0011+5012+0012+5013+0013+5014+0014+50A-210 10+83.81 PROP CURB INLET RIM 713.78 INV IN 708.55 (24") A-220 INV OUT 708.55 (24") A-200 A-240 13+87.78 PROP CURB INLET RIM 714.87 INV OUT 711.00 (15") A-230 PROP 62 LF 15" RCP @ 0.57%A-230 13+25.86 PROP CURB INLET RIM 714.47 INV IN 710.65 (15") A-240 INV OUT 710.40 (18")PROP 105 LF 18" RCP @ 0.62%A-220 12+20.86 PROP CURB INLET RIM 714.36 INV OUT 709.25 (24") A-210 PROP 137 LF 24" RCP @ 0.51%PROP 84 LF 24" RCP @ 0.54%A-20010+00PROP MHRIM 714.68INV IN 708.10 (24") A-210 2.7' COVERPROP GRADEPROP UNDERGROUND DETENTIONSYSTEM #1.SEE SHEET C-911 - C-912 FOR DETAILS2.4' COVER10 YR HGLPROP COMPACTED FILL0SCALE:1" = 20'2020510C-607STORMPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-607 PSTMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026EXISTING GRADEPROFILEPROPOSED GRADEHYDRAULIC GRADE LINECOMPACTED FILL DATUM ELEV690.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (EX-5 - B-150)6957007057107157206957007057107157209+5010+0010+5011+0011+5012+0012+5013+0013+5014+0014+5015+00PROP GRADEB-10010+18.08PROP MHRIM 703.41INV IN 697.50 (36") B-110INV IN 698.80 (12") B-101INV OUT 697.40 (36") EX-5 PROP 74 LF 36" RCP @ 1.42%PROP 18 LF 36" RCP @ 3.32%PROP 115 LF 36" RCP @ 0.78%B-12011+44.85 PROP MH RIM 713.00 INV IN 702.40 (36") B-130 INV OUT 702.30 (36") B-110 B-150 14+49.88 PROP MH RIM 715.34 INV OUT 704.75 (36") B-140 PROP 144 LF 36" RCP @ 0.52%B-140 13+06.22 PROP MH RIM 715.50 INV IN 704.00 (36") B-150 INV OUT 703.90 (36") B-130 2.8' COVERB-11010+92.27PROP MHRIM 710.14INV IN 701.70 (36") B-120INV OUT 698.55 (36") B-100 PROP 53 LF 36" RCP @ 1.14%7.5' COVER10 YR HGLPROP 46 LF 36" RCP @ 1.08%B-130 11+91.25 PROP MH RIM 713.75 INV IN 703.00 (36") B-140 INV OUT 702.90 (36") B-120 3.0' COVER 7.9' COVER 0SCALE:1" = 20'2020510C-608STORMPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-608 PSTMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026EXISTING GRADEPROFILEPROPOSED GRADEHYDRAULIC GRADE LINECOMPACTED FILL DATUM ELEV700.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (C-110 - C-122)7057107157057107159+5010+0010+5011+0011+505.9' COVERPROP GRADE10 YR HGLC-122 11+21.30 PROP CURB INLET RIM 711.52 INV OUT 707.60 (15") C-121 PROP 41 LF 15" HDPE @ 0.73%C-121 10+80.04 PROP MH RIM 713.29 INV IN 707.30 (15") C-122 INV OUT 707.20 (15") C-120 PROP 50 LF 15" HDPE @ 0.60%C-120 10+30.05 PROP CURB INLET RIM 714.33 INV IN 706.90 (15") C-121 INV IN 708.20 (18") C-130 INV OUT 706.15 (24") C-110 PROP 30 LF 24" RCP @ 0.60%C-110 10+00 PROP MH RIM 714.16 INV IN 705.97 (24") C-120 INV IN 707.50 (18") C-111 INV IN 709.50 (6") CO-23 INV OUT 705.47 (30") C-100 PROP COMPACTED FILL2.1' COVERDATUM ELEV695.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (C-210 - C-230)7007057107157207007057107157209+5010+0010+5011+0011+5012+00PROP GRADEPROP 80 LF 12" HDPE @ 1.56%C-22010+44.89PROP CURB INLETRIM 713.77INV IN 710.00 (12") C-230INV OUT 709.90 (12") C-210 PROP 36 LF 12" HDPE @ 1.37%C-21010+08.48PROP UNDERGROUND VAULT #2RIM 712.78INV IN 709.40 (12") C-220INV IN 707.90 (12") C-211C-23011+24.89PROP CURB INLETRIM 715.06INV OUT 711.25 (12") C-220 10 YR HGLPROP COMPACTED FILL2.0' COVER 2.1' COVER10+79 PROP 30" STM X-INGINV 703.05 4.6' CLEAR DATUM ELEV705.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (C-111 - C-113)7107157207107157209+5010+0010+5011+0011+50C-111 10+00 PROP CURB INLET RIM 717.30 INV IN 709.75 (18") C-112 INV OUT 709.65 (18") C-110 PROP 80 LF 12" RCP @ 2.18%C-113 11+15.64 PROP CURB INLET RIM 718.17 INV OUT 714.75 (12") C-112 PROP GRADE10 YR HGLPROP COMPACTED FILL5.0' COVERPROP 35 LF 18" RCP @ 1.13%C-112 10+35.27 PROP MH RIM 717.26 INV IN 713.00 (12") C-113 INV IN 710.65 (12") C-112A INV OUT 710.15 (18") C-111 11+04 PROP 8" STM INSERA TEE 0SCALE:1" = 20'2020510C-609STORMPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-609 PSTMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026EXISTING GRADEPROFILEPROPOSED GRADEHYDRAULIC GRADE LINECOMPACTED FILL DATUM ELEV700.007057107157207259+5010+0010+5011+0011+5012+0012+5013+0013+5014+0014+50C-10010+00PROP MHRIM 713.79INV IN 705.27 (30") C-110 PROP 286 LF 12" HDPE @ 0.51%PROP 152 LF 15" RCP @ 1.65%C-130 11+65.43 PROP MH RIM 715.51 INV IN 709.30 (15") C-140 INV IN 710.90 (15") OWS-OUT INV OUT 709.05 (18") C-120 PROP 109 LF 18" RCP @ 0.78%PROP GRADEPROP UNDERGROUND DETENTIONSYSTEM #2.SEE SHEET C-914 - C-915 FOR DETAILSPROP 26 LF 30" RCP @ 0.77%10 YR HGLPROP COMPACTED FILLC-150 14+10.32 PROP GRATE INLET GRT 716.50 INV IN 712.75 (12") C-160 INV OUT 712.50 (15") C-140 2.4' COVERPROP 93 LF 15" RCP @ 0.64%C-140 12+58.64 PROP CURB INLET RIM 714.06 INV IN 710.00 (15") C-150 INV OUT 709.90 (15") C-130 2.1' COVER 3.9' COVERPROP 30 LF 24" RCP @ 0.60%C-11010+25.98PROP MHRIM 714.16INV IN 705.97 (24") C-120INV IN 707.50 (18") C-111INV IN 709.50 (6") CO-23INV OUT 705.47 (30") C-100C-12010+56.03PROP CURB INLETRIM 714.33INV IN 706.90 (15") C-121INV IN 708.20 (18") C-130INV OUT 706.15 (24") C-110 SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (C-100 - C-160)0SCALE:1" = 20'2020510C-610STORMPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-610 PSTMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - STATION 14+50EXISTING GRADEPROFILEPROPOSED GRADEHYDRAULIC GRADE LINECOMPACTED FILL 70571071572072514+5015+0015+5016+0016+5017+0017+50C-160 16+96.51 PROP GRATE INLET GRT 717.50 INV OUT 714.20 (12") C-150 PROP 286 LF 12" HDPE @ 0.51%PROP GRADEPROP 286 LF 12" HDPE @ 0.51%C-15014+10.32PROP GRATE INLETGRT 716.50INV IN 712.75 (12") C-160INV OUT 712.50 (15") C-140 2.2' COVER 2.4' COVERSCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (C-100 - C-160)DATUM ELEV690.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (B-110 - B-112)6957007057107156957007057107159+5010+0010+5011+0011+50PROP GRADE10 YR HGLPROP UNDERGROUND DETENTIONSYSTEM #3.SEE SHEET C-917 - C-919 FOR DETAILSPROP 7 LF 36" RCP @ 2.14%PROP 53 LF 36" RCP @ 0.56%B-111 10+53.38 PROP MH RIM 708.06 INV IN 698.85 (36") B-112 INV OUT 698.85 (36") B-110 10+00 PROP MH RIM 710.14 INV IN 701.70 (36") B-120 INV OUT 698.55 (36") B-100 2.7' COVER B-112 10+60.38 PROP UNDERGROUND DETENTION INV OUT 699.00 (36") B-111 0SCALE:1" = 20'2020510C-611STORMPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-611 PSTMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - STATION 14+50 EXISTING GRADEPROFILEPROPOSED GRADEHYDRAULIC GRADE LINECOMPACTED FILL DATUM ELEV695.007007057107157207259+5010+0010+5011+0011+5012+0012+5013+0013+5014+0014+5015+00D-11010+14.19PROP CURB INLETRIM 707.30INV IN 703.57 (18") D-120INV IN 701.54 (30") EX-6INV OUT 701.35 (36") D-100 PROP 177 LF 18" RCP @ 0.84%D-130 12+76.30 PROP CURB INLET RIM 711.09 INV IN 706.03 (18") D-140 INV OUT 706.03 (18") D-120 PROP 177 LF 18" RCP @ 1.14%D-140 14+53.64 PROP CURB INLET RIM 712.95 INV IN 708.05 (18") D-150 INV OUT 708.05 (18") D-130 3.4' COVER PROP GRADEPROP UNDERGROUND DETENTIONSYSTEM #3.SEE SHEET C-917 - C-919 FOR DETAILS10 YR HGLPROP 276 LF 18" RCP @ 1.16%D-10010+00PROP UNDERGROUND DETENTIONINV IN 701.25 (36") D-110 PROP 14 LF 36" RCP @ 0.70%D-120 11+90.74 PROP MH RIM 709.95 INV IN 705.05 (18") D-130 INV OUT 705.05 (18") D-110 5.2' CLEAR SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (D-100 - D-170)0SCALE:1" = 20'2020510C-612STORMPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-612 PSTMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - STATION 15+00EXISTING GRADEPROFILEPROPOSED GRADEHYDRAULIC GRADE LINECOMPACTED FILL 70070571071572072515+0015+5016+0016+5017+0017+5018+0018+5019+0019+5020+0020+5021+00PROP 276 LF 18" RCP @ 1.16%D-150 17+29.98 PROP CURB INLET RIM 715.68 INV IN 711.24 (18") D-160 INV OUT 711.24 (18") D-140 PROP 138 LF 18" RCP @ 1.11%D-160 18+68.03 PROP CURB INLET RIM 717.51 INV IN 713.02 (18") D-170 INV OUT 712.77 (18") D-150 PROP 145 LF 18" RCP @ 3 .29% D-170 20+13.27 PROP CURB INLET RIM 721.62 INV OUT 717.80 (18") D-160 2.7' COVERPROP GRADE10 YR HGLPROP 276 LF 18" RCP @ 1.16%2.1' COVERSCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (D-100 - D-170)0SCALE:1" = 20'2020510C-613STORMPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-613 PSTMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - STATION 15+00 EXISTING GRADEPROFILEPROPOSED GRADEHYDRAULIC GRADE LINECOMPACTED FILL DATUM ELEV700.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (C-110 - C-111)7057107157207057107157209+5010+0010+5011+0011+5012+0012+50C-111 11+62.96 PROP CURB INLET RIM 717.30 INV IN 709.75 (18") C-112 INV OUT 709.65 (18") C-110 PROP GRADE10 YR HGLPROP COMPACTED FILL4.9' COVER C-110 10+00 PROP MH RIM 714.16 INV IN 705.97 (24") C-120 INV IN 707.50 (18") C-111 INV IN 709.50 (6") CO-23 INV OUT 705.47 (30") C-100 PROP 163 LF 18" RCP @ 1.32%0SCALE:1" = 20'2020510C-614STORMPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-614 PSTMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026EXISTING GRADEPROFILEPROPOSED GRADEHYDRAULIC GRADE LINECOMPACTED FILL DATUM ELEV702.50SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (C-130 - C-143)7057107157207057107157209+5010+0010+5011+0011+5012+0012+5013+00PROP 121 LF 15" HDPE @ 0.62%C-143 12+49.35 PROP CURB INLET RIM 716.32 INV OUT 712.75 (15") C-142 PROP 40 LF 15" HDPE @ 0.76%C-142 11+27.99 PROP MH RIM 716.74 INV IN 712.00 (15") C-143 INV OUT 711.90 (15") C-141 C-141 10+54.99 PROP MH RIM 716.99 INV IN 713.00 (8") C-141A INV IN 711.40 (15") C-142 INV OUT 711.30 (15") OWS-IN PROP 73 LF 15" HDPE @ 0.68%PROP 6 LF 15" HDPE @ 1.54%PROP GRADEPROPOIL/WATERSEPARATOR2.2' COVER 4.2' COVER10 YR HGLC-130 10+00 PROP MH RIM 715.51 INV IN 709.30 (15") C-140 INV IN 710.90 (15") OWS-OUT INV OUT 709.05 (18") C-120 DATUM ELEV700.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (C-210 - C-211)7057107157057107159+5010+0010+5011+00C-210 10+00 PROP MH RIM 712.78 INV IN 709.40 (12") C-220 INV IN 707.90 (12") C-211 PROP 28 LF 12" HDPE @ 2.83%C-211 10+28.29 PROP CURB INLET RIM 712.60 INV OUT 708.70 (12") C-210 PROP GRADE2.3' COVER PROP COMPACTED FILL0SCALE:1" = 20'2020510EXISTING GRADEPROFILEPROPOSED GRADEHYDRAULIC GRADE LINECOMPACTED FILL May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-615 PSTMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026C-615STORMPROFILES DATUM ELEV700.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (C-112 - C-112A)7057107157207257057107157207259+5010+0010+5011+0011+50PROP 68 LF 12" RCP @ 1.63%C-112A 10+67.66 PROP CLEANOUTS GRATE A 715.03 INV IN 711.95 (8") INV OUT 711.75 (12") C-112 PROP GRADEPROP COMPACTED FILL10+25 PROP 8" SAN X-ING INV 709.30 2.4' COVER 5.7' COVER C-112 10+00 PROP MH RIM 717.26 INV IN 713.00 (12") C-113 INV IN 710.65 (12") C-112A INV OUT 710.15 (18") C-111 0.9' CLEAR 10 YR HGL0.5' CLEAR 10+12 PROP 8" W/L X-INGROOF DRAIN SCHEDULEFROMBEND-2BLDG-ABLDG-BBLDG-CBLDG-DBLDG-EBLDG-FBLDG-GBLDG-HBLDG-IBLDG-JBLDG-KBLDG-LBLDG-MBLDG-OC-10ACO-1CO-2CO-3CO-4LOWER INVERT715.75717.60717.90717.20717.00718.82717.10717.10713.28713.28717.10716.10717.10716.00717.10712.60717.40717.70717.00716.05LENGTH14'4'7'7'27'27'10'10'7'7'4'4'27'8'27'38'76'44'62'20'SIZE(in.)4"8"8"8"8"8"8"8"8"8"8"8"8"8"8"8"8"8"8"8"SLOPE(%)4.15%5.00%2.93%2.93%3.55%11.59%17.04%16.65%1.44%9.76%14.81%15.00%7.68%6.60%1.31%1.30%6.90%1.59%1.53%1.50%UPPER INVERT715.17717.40717.70717.00716.05715.75715.40715.40713.18712.60716.50715.50715.05715.45716.75712.10712.16717.00716.05715.75TOWYE-15CO-1CO-2CO-3CO-4CO-5CO-8CO-9CO-10C-10ACO-12CO-13CO-15CO-17CO-19CO-11A-150CO-3CO-4CO-5TYPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEROOF DRAIN SCHEDULEFROMCO-5CO-6CO-7CO-8CO-9CO-10CO-11CO-12CO-13CO-14CO-15CO-16CO-17CO-18CO-18CO-19DS-1DS-2WYE-15LOWER INVERT715.75715.45714.90715.40716.50713.18712.10716.50715.50714.60715.05715.50715.60716.05716.50716.75715.83715.83715.17LENGTH19'35'65'14'40'38'21'29'58'36'35'36'8'37'8'48'4'4'3'SIZE(in.)8"8"8"8"8"8"8"8"8"8"8"8"8"8"8"8"4"4"4"SLOPE(%)1.59%1.55%1.53%10.59%2.77%1.52%0.71%3.50%1.43%2.21%1.27%1.24%1.25%1.20%5.40%1.46%2.08%18.25%19.20%UPPER INVERT715.45714.90713.90713.90715.40712.60711.95715.50714.67713.80714.60715.05715.50715.60716.05716.05715.75715.17714.50TOCO-6CO-7A-111A-111CO-8C-10ACO-13CO-14CO-15CO-16CO-17BLDG-NCO-18BEND-2WYE-15WYE-14TYPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEC-113C-112AC-112ROOF DRAIN SCHEDULEFROMC-141ACNPY-ACNPY-BCNPY-CCNPY-DCNPY-ECNPY-FCNPY-GCNPY-HCNPY-ICNPY-JCNPY-KCNPY-LCNPY-MCNPY-NCNPY-OCNPY-PCO-22WYE-1WYE-2WYE-4WYE-5WYE-6LOWER INVERT713.25713.50713.20714.00713.20715.00714.25715.50714.13713.43713.43713.43713.43716.10716.38716.66716.87711.93711.91712.58713.24713.91712.11LENGTH10'15'3'15'3'6'3'15'3'10'10'10'10'10'10'10'10'21'17'34'4'34'17'SIZE(in.)8"4"4"4"4"4"4"4"4"4"4"4"4"4"4"4"4"6"6"6"6"6"6"SLOPE(%)2.48%8.52%6.12%3.40%6.66%9.59%8.33%3.40%6.12%6.79%1.83%5.60%2.07%4.95%4.95%4.95%4.95%1.08%1.21%1.95%1.95%1.95%1.08%UPPER INVERT713.00712.25713.01713.50713.00714.45714.00715.00713.94712.75713.25714.00713.22715.60715.88716.16716.37711.70711.70711.91713.16713.24711.93TOC-141WYE-1WYE-1WYE-2WYE-2BEND-1WYE-4WYE-5WYE-5WYE-6WYE-7WYE-8WYE-9WYE-10WYE-11WYE-12WYE-13CO-21CO-21WYE-1WYE-3WYE-4CO-22TYPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEHDPEROOF DRAIN SCHEDULEFROMWYE-7WYE-8WYE-9WYE-10WYE-13LOWER INVERT712.48712.85713.22712.11713.22LENGTH34'34'34'17'34'SIZE(in.)6"6"6"6"6"SLOPE(%)1.08%1.08%1.08%1.08%1.08%UPPER INVERT712.11712.48712.85711.93712.85TOWYE-6WYE-7WYE-8CO-23WYE-12TYPEHDPEHDPEHDPEHDPEHDPEDATUM ELEV695.00SCALE: 1"= 20 ' HORIZONTAL 1"= 2 ' VERTICALPROPOSED STORM PROFILE (D-120 - D-220)7007057107157207007057107157209+5010+0010+5011+0011+5012+00D-21010+89.78PROP CURB INLETRIM 711.40INV IN 707.10 (12") D-220 INV OUT 707.00 (12") D-120 PROP 40 LF 12" HDPE @ 0.50%PROP 90 LF 12" HDPE @ 1.67%D-220 11+30.15 PROP CURB INLET RIM 711.52 INV OUT 707.30 (12") D-210 2.6' COVER PROP GRADE10+30 EX 8" SAN X-INGINV 698.30 6.9' CLEARPROP UNDERGROUND DETENTIONSYSTEM #3.SEE SHEET C-917 - C-919 FOR DETAILS10 YR HGLPROP COMPACTED FILLD-12010+00PROP UNDERGROUND DETENTIONINV IN 705.50 (12") D-210 0SCALE:1" = 20'2020510C-616STORMPROFILES May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-616 PSTMYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026EXISTING GRADEPROFILEPROPOSED GRADEHYDRAULIC GRADE LINECOMPACTED FILL 0SCALE:1" = 20'2020510C-617STORMCOMPUTATIONS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-617 STORM COMPSYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/202610 YEAR STORM COMPUTATIONSFromToDrain.RunoffCAInletRainfallQInvert Elev.LengthSlopeDia.nCapacityVelocityFlow TimeQ /V /VfullRemarksPointPointAreaCoeff.Incr.∑TimeIntensityIncr.Known∑UpperLowerIncr.∑QfullVfull(acres)C(min)(in/hr)(cfs)(cfs)(cfs)(ft)(ft)(ft)( % )(in)(cfs)(fps)(min)(min)rev5/08EX1EX20.310.720.220.225.006.481.43–1.43714.53713.70268.000.31%150.0133.602.711.656.650.400.922.94START EXIST COSTCO CONVEYANCEEX2EX30.640.590.380.606.656.002.28–3.60713.25712.62166.000.38%210.0139.793.670.757.400.370.904.07EX3A-1500.480.580.280.887.405.781.62–5.09712.47712.3633.000.33%240.01313.103.850.147.540.390.924.17END EXIST COSTCO CONVEYANCEA-150A-1400.170.900.151.037.545.740.86–5.91712.16711.7093.080.50%180.0137.444.650.337.870.791.104.21A-140A-1300.690.850.591.627.875.643.33–9.14711.20710.10209.440.53%240.01316.445.320.668.530.561.025.23A-130A-1200.640.850.543.648.535.452.94–19.83710.10709.4070.650.98%240.01322.508.060.158.680.881.137.16A-120A-1100.340.850.294.458.685.411.57–24.06708.90708.10154.480.52%300.01329.606.700.389.060.811.116.03A-110A-100–––6.069.065.29––32.08708.10706.45218.120.76%300.01335.778.210.449.500.901.137.29A-133A-1320.200.850.170.175.006.481.10–1.10715.33714.0091.001.46%120.0134.324.560.335.330.250.835.50A-132A-1310.640.850.540.715.336.383.45–4.54714.00712.7582.501.52%150.0137.976.700.215.540.571.036.50A-131A-1300.900.850.771.485.546.324.87–9.36712.50711.4041.902.63%150.01310.499.630.075.610.891.138.55A-122A-1210.530.700.370.375.006.482.40–2.40715.38714.00110.001.25%120.0134.005.260.355.350.601.035.09A-121A-1200.180.850.150.525.356.380.96–3.32714.00712.75102.001.23%120.0133.955.640.305.650.841.125.04A-111A-1101.790.901.611.615.006.4810.43–10.43713.07711.15156.861.22%180.01311.647.420.355.350.901.136.59Cumulative Area from Roof DrainsA-240A-2300.680.850.580.585.006.483.76–3.76711.18710.6261.820.91%150.0136.175.250.205.200.611.055.02A-230A-2200.730.850.621.205.206.423.98–7.70710.12709.42105.000.67%180.0138.605.480.325.520.901.134.87A-220A-2100.460.850.391.595.526.332.47–10.06708.92708.60127.060.25%240.01311.384.080.526.040.881.133.62A-210A-2000.750.850.642.236.046.183.95–13.77708.60708.2082.570.48%240.01315.795.660.246.280.871.135.03B-150B-140–––––––39.4739.47704.75704.00143.670.52%360.01348.327.600.325.320.821.116.84OUTLET CONTROL STRUCTURE #1B-140B-130––––––––39.47703.90703.00114.960.78%360.01359.178.870.225.540.671.068.37B-130B-120––––––––61.86702.90702.4046.411.08%360.01369.4211.060.075.610.891.139.82B-120B -110––––––––61.86702.30701.7052.571.14%360.01371.4511.320.085.690.871.1210.11B-110B-100––––––––24.97698.55697.5058.391.80%360.01389.6810.850.095.220.280.8612.69B-100EX-5–––0.145.226.42––25.87697.40696.8018.083.32%360.013121.8313.370.025.240.210.7817.24B-131B-130–––––––22.3922.39703.16703.0037.150.43%300.01326.996.110.105.100.831.115.50OUTLET CONTROL STRUCTURE #2B-111B-110–––––––24.9724.97698.85698.5553.380.56%360.01350.146.970.135.130.500.987.09OUTLET CONTROL STRUCTURE #3B-101B-1000.160.900.140.145.006.480.91–0.91700.00698.8047.002.55%120.0135.715.210.155.150.160.727.27C-160C-1500.360.750.270.275.006.481.75–1.75714.20712.75286.000.51%120.0132.543.471.376.370.691.073.24C-150C-140–––0.276.376.08––1.75712.50710.00152.001.64%150.0138.315.250.486.850.210.786.77C-140C-1300.420.650.270.546.855.941.60–3.20709.90709.3093.000.65%150.0135.204.430.357.200.621.054.24C-130C-120–––1.187.205.84––6.89709.05708.20109.000.78%180.0139.305.760.327.520.741.095.26C-120C-1100.010.900.011.667.525.740.06–9.54706.15705.9730.000.60%240.01317.575.680.097.610.541.025.59C-110C-1000.27––2.067.615.72––19.65705.47705.2726.000.77%300.01336.077.470.067.670.541.027.35FROM RD-2C-122C-1210.350.900.320.325.006.482.07–2.07707.60707.3041.000.73%150.0135.544.170.165.160.370.924.51C-121C-1200.170.900.150.475.166.430.96–3.02707.20706.9050.000.60%150.0135.024.220.205.360.601.034.09C-230C-2200.120.900.110.115.006.480.71–0.71711.25710.0080.001.56%120.0134.474.080.335.330.160.725.69C-220C-2100.190.900.170.285.336.381.09–1.79709.90709.4036.001.39%120.0134.215.060.125.450.430.945.36C-211C-2100.860.900.770.775.006.484.99–4.99708.70707.9028.002.86%120.0136.048.550.055.050.831.117.69C-113C-1120.170.900.150.155.006.480.973.674.64714.75713.0080.002.19%120.0135.287.570.185.180.881.136.73Known Flow from upstream roof leadersC-112C-111–––0.295.186.43––9.73710.15709.7535.261.13%180.01311.227.110.085.260.871.126.35C-111C-1100.120.900.110.405.266.400.70–10.43709.65707.50162.961.32%180.01312.107.670.355.610.861.126.85C-112AC-1120.160.900.140.145.006.480.914.205.11711.75710.6568.001.62%150.0138.247.020.165.160.621.056.71Known Flow from upstream roof leadersC-143C-1420.710.900.640.645.006.484.15–4.15712.75712.00121.000.62%150.0135.104.620.445.440.811.114.16C-142C-141–––0.645.446.35––4.15711.90711.4073.000.68%150.0135.364.820.255.690.771.104.37C-141OWS-IN–––0.645.696.28––4.15711.30711.206.001.67%150.0138.366.700.015.700.500.986.81OWS-INC-130–––0.645.706.28––4.15711.20710.9040.000.75%150.0135.614.950.135.830.741.084.57D-170D-1600.240.900.220.225.006.481.43–1.43717.80713.02145.003.30%180.01319.126.240.395.390.070.5810.82D-160D-1500.190.900.170.395.396.371.08–2.48712.77711.25134.101.14%180.01311.254.940.455.840.220.786.36D-150D-1400.050.900.050.445.846.230.31–2.74711.24708.05279.901.14%180.01311.245.110.916.750.240.806.36D-140D-1300.370.800.300.746.755.971.79–4.42708.05706.03177.341.14%180.01311.255.880.507.250.390.926.36D-130D-1200.220.900.200.947.255.821.16–5.47706.03705.0585.561.14%180.01311.256.260.237.480.490.986.37D-120D-110–––0.947.485.76––5.47705.05703.57176.540.84%180.0139.665.550.538.010.571.025.46D-110D-1000.520.650.341.2810.105.001.70–49.05701.35701.2514.190.70%360.01356.148.940.0310.130.871.137.94EX-6D-110–––––––42.6542.65702.77701.5473.781.67%300.01353.1011.940.1010.100.801.1010.82EXISTING S COSTELLO DR DISCHARGE FROMHYDROCAD2 YEAR INLET COMPUTATIONSInletDACIQQbQtSSxnTWSwOn Grade Inlets OnlySag Inlets OnlyRemarksNo.TypeLengthDrainRunoffIntenIncr.CarryAccum.GutterPvmtSpreadGutterWGutterSwEoaS'wSe=SxLt,Comp.L,SpecLEQiQbDownQidhdTsAreaCoeff--sityFlow-overFlowSlopeCrossOnWidth/Cross/(App.= a /+ S'wLength-ified/Eff.Int'xByp.StreamInt'xDepth/SpreadicientFlowSlopeGradeTSlopeSx9C-8)(12W)(Eo)(9C-17)LengthLt(9C-18)FlowFlowStr.FlowhIn Sag(ft)(acres)(in/hr)(cfs)(cfs)(cfs)(%)(%)(ft)(ft)(%)(in)(%)(%)(ft)(ft)(cfs)(cfs)(cfs)(ft)(ft)(ft)rev5/08InletInletDACIQQbQtSSxnTWSwOn GradeSag InletsRemarksNo.TypeLenDrainRunoffIntenIncr.CarryAccum.GutterPvmtSpreadGutterWGutterSwEoaS'wSe=SxLt,Comp.L,SpecLEQiQbDownQidhdTsAreaCoeff--sityFlow-overFlowSlopeCrossOnWidth/Cross/(App.= a /+ S'wLength-ified/Eff.Int'xByp.StreamInt'xDepth/SpreadicientFlowSlopeGradeTSlopeSx9C-8)(12W)(Eo)(9C-17)LengthLt(9C-18)FlowFlowStr.FlowhIn Sag(ft)(acres)(in/hr)(cfs)(cfs)(cfs)(%)(%)(ft)(ft)(%)(in)(%)(%)(ft)(ft)(cfs)(cfs)(cfs)(ft)(ft)(ft)rev5/08A-150Curb DI-3C6.000.170.904.700.720.000.722.000.020.002.008.333.520.000.000.000.720.100.460.221.22In SagA-140Curb DI-3C6.000.690.854.702.760.002.762.000.020.002.008.333.520.000.000.002.760.250.460.546.16In SagA-130Curb DI-3C6.000.640.854.702.560.002.562.000.020.002.008.333.520.000.000.002.560.240.460.525.55In SagA-120Curb DI-3C6.000.340.854.701.360.001.362.000.020.002.008.333.520.000.000.001.360.160.460.341.87In SagA-133Curb DI-3A6.000.200.854.700.800.000.801.002.000.024.492.000.458.334.170.923.5214.6615.535.216.001.151.000.800.00A-1310.000.000.000.000.00On GradeA-132Curb DI-3A8.000.640.854.702.560.002.561.002.000.028.842.000.238.334.170.643.5214.6611.3710.248.000.780.942.390.17A-1310.000.000.000.000.00On GradeA-131Curb DI-3C6.000.900.854.703.600.173.772.000.020.002.008.333.520.000.000.003.770.310.460.679.05In SagA-122Curb DI-3A6.000.530.704.701.740.001.742.000.020.002.008.333.520.000.000.001.740.180.460.402.87In SagA-121Curb DI-3A6.000.180.854.700.720.000.722.000.020.002.008.333.520.000.000.000.720.100.460.221.22In SagA-240Curb DI-3A6.000.680.854.702.720.002.722.000.020.002.008.333.520.000.000.002.720.250.460.546.04In SagA-230Curb DI-3C6.000.730.854.702.920.002.922.000.020.002.008.333.520.000.000.002.920.260.460.576.64In SagA-220Curb DI-3C0.460.854.701.840.001.842.000.020.002.008.333.52In SagA-210Curb DI-3A6.000.750.854.703.000.003.002.000.020.002.008.333.520.000.000.003.000.260.460.586.87In SagB-101Curb DI-3A6.000.160.904.700.680.030.716.002.000.021.812.001.108.334.171.003.5214.6616.668.126.000.740.910.640.070.000.000.000.000.000.00On GradeC-160Comb DI-2B6.000.360.754.701.270.001.272.000.020.002.008.333.520.000.000.001.270.150.460.321.79In SagC-150Comb DI-2B4.000.000.000.000.000.000.002.000.020.002.008.333.520.000.000.000.000.000.460.000.00In SagC-140Curb DI-3C6.000.420.654.701.280.321.602.000.020.002.008.333.520.000.000.001.600.170.460.382.37In SagC-120Curb DI-3B6.000.010.904.700.040.000.041.602.000.020.812.002.478.334.171.003.5214.6616.661.676.003.581.000.040.00B-1010.000.000.000.000.00On GradeC-122Curb DI-3B8.000.350.904.701.480.001.482.402.000.025.102.000.398.334.170.883.5214.6614.968.988.000.890.981.450.03B-1010.000.000.000.000.00On GradeC-121Curb DI-3B6.000.170.904.700.720.000.722.002.000.022.992.000.678.334.170.993.5214.6616.515.926.001.011.000.720.00B-1010.000.000.000.000.00On GradeC-230Curb DI-3C6.000.120.904.700.510.000.512.000.020.002.008.333.520.000.000.000.510.080.460.180.97In SagC-220Curb DI-3C6.000.190.904.700.800.000.802.000.020.002.008.333.520.000.000.000.800.110.460.241.32In SagC-211Curb DI-3C6.000.860.904.703.640.003.642.000.020.002.008.333.520.000.000.003.640.300.460.668.70In SagC-113Curb DI-3C6.000.170.904.700.720.000.722.000.020.002.008.333.520.000.000.000.720.100.460.221.22In SagC-111Curb DI-3B6.000.120.904.700.510.000.511.002.000.022.982.000.678.334.170.993.5214.6616.514.156.001.451.000.510.000.000.000.000.000.000.00On GradeC-143Curb DI-3B8.000.710.904.703.000.003.001.002.000.029.542.000.218.334.170.603.5214.6610.8211.298.000.710.892.680.32C-1400.000.000.000.000.00On GradeD-170Curb DI-3A12.000.240.904.701.020.001.021.002.000.025.312.000.388.334.170.873.5214.6614.755.9412.002.021.001.020.00D-1600.000.000.000.000.00On GradeD-160Curb DI-3A14.000.190.904.700.800.000.801.002.000.024.512.000.448.334.170.923.5214.6615.515.2314.002.681.000.800.00D-1400.000.000.000.000.00On GradeD-150Curb DI-3A4.000.050.904.700.210.000.211.002.000.021.622.001.248.334.171.003.5214.6616.662.864.001.401.000.210.00D-1400.000.000.000.000.00On GradeD-140Curb DI-3A14.000.370.804.701.390.001.391.002.000.026.442.000.318.334.170.793.5214.6613.607.1214.001.971.001.390.00D-1300.000.000.000.000.00On Grade 0SCALE:1" = 20'2020510C-618STORMCOMPUTATIONS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PSTM-NJA220135.00-0A----->LAYOUT: C-618 STORM COMPSYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-PSTMPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/202610 YEAR HGL COMPUTATIONSStructureOutletDoQoLoSfoHfJUNCTION LOSSFinalInletTop /InletPre-CastJunctionRemarksNo.WSEHWSEThroatShapingStructureLoss(in)(%)VoHoQiViQi · ViVi^2/2gHiAngleKHdHt1.3 Ht0.5 HtElev.Reductionrev5/08EX1#####151.43##########0.132.710.030.030.040.020.15##########Yes–YesEX2#####213.60##########0.093.670.051.432.713.880.110.04180.230.030.120.150.080.16##########Yes–YesEX3#####245.0933.00#####0.023.850.063.603.6713.210.210.0770.090.020.150.190.100.11##########Yes–YesA-150#####185.9193.08#####0.294.650.085.093.8519.610.230.08190.240.050.22–0.110.40##########YesYesYesA-140#####249.14##########0.345.320.115.914.6527.490.340.12––0.000.230.300.150.49##########YesYesYesA-130#####24####70.65#####0.548.060.259.369.6390.131.440.5070.090.130.88–0.440.98##########YesYesYesA-120#####30##############0.536.700.17####8.06#####1.010.35770.650.651.18–0.591.12##########YesYesYesA-110#####30##############1.338.210.26####6.70#####0.700.2470.090.060.57–0.281.62##########YesYesYesA-133#####121.1091.00#####0.534.560.080.080.110.050.58##########YesYesYesA-132#####154.5482.50#####0.416.700.171.104.565.020.320.11900.700.230.510.670.330.74##########YesYesYesA-131#####159.3641.90#####0.889.630.364.546.7030.440.700.24770.650.451.061.370.691.57##########YesYesYesA-122#####122.40##########0.585.260.110.110.140.070.65##########YesYesYesA-121#####123.32##########0.895.640.122.405.2612.620.430.15––0.000.270.360.181.06##########YesYesYesA-111#####18##############1.557.420.210.210.280.141.69##########YesYesYesA-240#####153.7661.82#####0.215.250.110.110.140.070.28##########YesYesYesA-230#####187.70##########0.565.480.123.765.2519.760.430.15––0.000.270.350.170.74##########YesYesYesA-220#####24##############0.254.080.067.705.4842.190.470.16––0.000.230.300.150.40##########YesYesYesA-210#####24####82.57#####0.315.660.12####4.0841.050.260.09900.700.180.400.510.260.56##########YesYesYesB-150#####36##############0.507.600.220.22–0.110.62##########YesYesYesB-140#####36##############0.408.870.31####7.60#####0.900.31180.230.200.82–0.410.81##########YesYesYesB-130#####36####46.41#####0.40####0.48####8.87#####1.220.43––0.000.90–0.450.85##########YesYesYesB-120#####36####52.57#####0.45####0.50#############1.900.67440.460.872.03–1.021.47##########YesYesYesB-110#####36####58.39#####0.08####0.46####6.97#####0.760.26460.470.361.08–0.540.62##########YesYesYesB-100#####36####18.08#####0.03####0.69#############1.830.64130.170.301.64–0.820.85##########YesYesYesB-111#####36####53.38#####0.076.970.190.19–0.090.17##########YesYesYesB-101#####120.9147.00#####0.035.210.110.110.140.070.10##########YesYesYesC-160#####121.75##########0.693.470.050.050.060.030.72##########YesYesYesC-150#####151.75##########1.505.250.111.753.476.080.190.07680.600.110.29–0.141.64##########YesYesYesC-140#####153.2093.00#####0.234.430.081.755.259.190.430.15180.230.100.320.420.210.44##########YesYesYesC-130#####186.89##########0.475.760.134.154.9520.560.380.13250.300.110.38–0.190.66##########YesYesYesC-120#####249.5430.00#####0.055.680.136.895.7639.670.520.18700.610.310.62–0.310.36##########YesYesYesC-110#####30####26.00#####0.067.470.22####7.6779.970.910.32900.700.641.18–0.590.65##########YesYesYesC-122#####152.0741.00#####0.044.170.070.070.090.040.09##########YesYesYesC-121#####153.0250.00#####0.114.220.072.074.178.640.270.09760.640.170.340.440.220.33##########YesYesYesC-230#####120.7180.00#####0.454.080.060.060.080.040.49##########YesYesYesC-220#####121.7936.00#####0.095.060.100.714.082.890.260.09350.390.100.290.380.190.28##########YesYesYesC-113#####124.6480.00#####1.367.570.220.220.290.141.50##########YesYesYesC-112#####189.7335.26#####0.307.110.205.117.0235.880.770.27900.700.541.00–0.500.80##########YesYesYesC-112A#####155.1168.00#####0.437.020.190.19–0.100.52##########YesYesYesC-111#####18##############1.617.670.239.737.1169.180.790.27900.700.551.05–0.532.13##########YesYesYesD-170#####181.43##########3.586.240.150.150.200.103.68##########YesYesYesD-160#####182.48##########0.334.940.091.436.248.930.610.2140.050.030.340.440.220.55##########YesYesYesD-150#####182.74##########1.995.110.102.484.9412.250.380.1350.060.020.26–0.132.12##########YesYesYesD-140#####184.42##########0.825.880.132.745.1114.010.410.1420.020.010.290.370.191.01##########YesYesYesD-130#####185.4785.56#####0.236.260.154.425.8825.990.540.1970.090.050.390.500.250.48##########YesYesYesD-120#####185.47##########0.485.550.125.476.2634.230.610.21170.210.130.46–0.230.71##########YesYesYesD-110#####36####14.19#####0.088.940.31#############2.220.78900.701.552.64–1.321.40##########YesYesYesEX-6#####30####73.78#####0.80####0.550.55–0.281.07##########Yes–YesD-220#####120.7840.37#####0.204.900.090.090.120.060.26##########YesYesYesD-210#####121.2989.78#####0.705.030.100.784.903.820.370.1380.100.040.270.350.170.87##########YesYesYes10 YEAR HEADWATER COMPUTATIONSStructureDACIQHeadRim / Invert10 YrRemarksrev 5/08 9:17 No.TypeDrainageRunoffIntensity10 Yr FlowWaterElevationWSEAreaCoefficient(ac)(in/hr)(cfs)(ft)(ft)(ft)C-112AGrate Inlet0.160.906.480.930.26Rim 715.03715.29 FRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'PROP. SAWCUTLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP.SAWCUTLOWLOWLOWLOWLOW LOWLOWLOWLOWLOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWPROP. SAWCUTPROP.SAWCUT55'R5'R6'R3.1'R5'R5'R4.9'R6.9'R15'R5'R10'20'24'5'R9'R24'20'19.5'9.3'PROP 5' SIDEWALK5'1'R2'R2'R1'R1'R1'R1'R25'R1 4 'PROPSTOP SIGNPROPACCESSIBLERAMP28.5'TPTPTPTPTPTPTC 725.91BC 725.41TC 726.10BC 725.60TC 726.10BC 725.60TC 725.96BC 725.46TC 725.95BC 725.45TC 726.13BC 725.63TC 726.07BC 725.57TC 725.82BC 725.32ME|G 724.9±ME|G 725.3±ME|G 725.2±ME|G 725.4±ME|G 725.8±ME|G 725.7±ME|G 725.6±ME|G 725.5±ME|G 725.4±ME|G 725.3±ME|BC 724.46ME|G 724.7±TC 725.51BC 725.01RIM 724.87F-100G 725.33G 725.25G 725.29TC 725.93BC 725.43TC 725.93BC 725.43TC 725.93BC 725.43TC 726.00BC 725.50ME|G 725.09TC 725.06BC 724.56TC 725.93BC 725.43TC 725.86BC 725.36TC 725.96BC 725.46G 725.79G 725.57G 725.69TC 725.81BC 725.31726725725G 724.96G 724.90ME|G 725.1±F-110TC 725.21BC 724.71TC 725.10BC 724.60ME|G 725.1±G 725.48G 725.69G 725.76G 725.37G 724.47G 725.28G 725.20G 724.97G 725.04ME|G 724.91ME|G 724.97G 725.30G 725.39G 725.75G 725.82G 725.70G 725.61C-701FRONT ROYALPIKE TAPERLANE May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-ROAD-NJA220135.00-0A----->LAYOUT: C-701 PRODYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-ROADPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026FRONT ROYAL PIKE TAPER LANE - TYPICAL SECTIONNOT TO SCALE3:1 MAX3:1 MAXVAR. 1'-2'2'VAR 0' - 26'12" SEE NOTE 1PROP CG-62" SM-9.5A8" CTA6" BM-25.0EX. CURB ANDGUTTER (TBR)PROP SAWCUTEX SMPROP 5' SIDEWALKFRONT ROYAL PIKE PLAN AND PROFILE NOTES:1.PROPOSED WIDENING TO BE DONE IN ACCORDANCE WITH VDOT ROAD AND BRIDGESTANDARDS WP-2.2.EXISTING CROSS SLOPES ALONG THE EXISTING PORTION OF FRONT ROYAL PIKE SHALLBE MAINTAINED AND EXTENDED. TO PROMOTE POSITIVE DRAINAGE, PROPOSED SLOPESMAY VERY. REFER TO PROPOSED SPOT ELEVATIONS IN PLAN VIEW ON THIS SHEET.3.FOR BITUMINOUS CONCRETE AND AGGREGATE BASE DESIGNATIONS REFER TO VDOTSTANDARDS AND SPECIFICATIONS.4.ALL BASE, SUBBASE AND SUBGRADE SHALL BE COMPACTED TO 100% OF THEORETICALMAXIMUM DENSITY AS DETERMINED BY ASTM D-698 METHOD WITHIN PLUS OR MINUS20% OF OPTIMUM MOISTURES. THIS STANDARD OF COMPACTION IS TO APPLY TO THESUPPORT MATERIAL FOR ALL PAVED AREAS, CURB AND GUTTER AND SIDEWALKS.5.CONTRACTOR SHALL MILL, OVERLAY AND/OR REPLACE EXISTING ASPHALT IN ORDER TOPROVIDE A SMOOTH TRANSITION FROM THE EXISTING ASPHALT TO THE PROPOSEDGUTTER LINE.6.PROPOSED ELEVATIONS ARE APPROXIMATE; THE CONTRACTOR SHALL PROVIDECENTER LINE AND EDGE OF PAVEMENT SHOTS AT 25' INTERVALS TO THE DESIGNENGINEER PRIOR TO STAKE OUT TO VERIFY/MODIFY PROPOSED TO ELEVATIONS TOPROVIDE SMOOTH EXTENSION OF THE EXISTING PAVEMENT.7.FINAL PAVEMENT THICKNESS TO BE DETERMINED BASED UPON CBR'S AND BORINGS OFEXISTING FRONT ROYAL PIKE.1"=20'02051020MILL AND OVERLAY PER WP-2 TO THE EDGE OFTHE EXISTING TRAVEL LANECOMMERCIAL ENTRANCE - TYPICAL SECTIONNOT TO SCALE(TYPICAL ALL COSTELLO DRIVE (RTE 11) ENTRANCES2.5'VAR 12-18'PROP CG-62" SM-9.5A8" CTA6" BM-25.0COMMERCIAL ENTRANCE NOTES:1.PAVEMENT DESIGN SHOWN IS PRELIMINARY. FINAL PAVEMENT DESIGN WILL BE BASED ON ACTUAL FIELD CBR TESTRESULTS AND EXISTING CORE DATA SUBMITTED FOR VDOT REVIEW AND APPROVAL PRIOR TO CONSTRUCTION.2.LIMITS OF FULL-DEPTH PAVEMENT WIDENING ALONG ROUTE 11 SHALL BE DETERMINED BY EXCAVATION IN THEPRESENCE OF A VDOT INSPECTOR, USING MATCHING CORE SAMPLES PER VDOT WP-2 DETAIL.3.SEE VDOT REF 502 - METHOD OF TREATMENT (CONNECTION FOR STREET INTERSECTIONS AND COMMERCIALENTRANCES) FOR ADDITIONAL ENTRANCE DETAILS.CENTERLINEPROP CROSS SLOPE PER GRADING PLAN (2% TYPICAL)VAR 12' - 18'2.5'PROP CROSS SLOPE PER GRADING PLAN (2% TYPICAL)8.33%8.33% PROPLIGHT(TYP ) PROP 5' SIDEWALK LODLODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LO D LODLODLODLODLOW LO W LOWLOWLOWLOWLOWLOW TOTAL L IM ITS OF D ISTURBANCE = LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOWLOW14.5'365' SDL (35 MPH) LINE OF SIGHT - LEFT EYE OBJ10+00 11+00 12+00 13+00 13+65.59 10+50 11+50 12+50 13+50WE SNAD83 NAD83DATUM ELEV 717.50 SCALE: 1"= 30 ' HORIZONTAL 1"= 3 ' VERTICAL SIGHT DISTANCE PROFILE - FRONT ROYAL PIKE - ENTRANCE 1 720 725 730 735 720 725 730 735 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 EYE 3.5'3.5'365' LINE OF SIGHT - LEFT PROP GRADE OBJ May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SGHT-NJA220135.00----->LAYOUT: C-702 SIGHT DISTANCE 1YGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00 JDM GE 04/29/2026 P-CIVL-SGHT 35O3 6,7E3/$1 'O&80E176 PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - 5E9,6,O16 REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-702 6,*+7 ',67$1&E 3/$1$1' 35O),/E 1"=30' 0 307.51530 6,*+7',67$1&E3/$19,E:)5O175OY$/3,.EE175$1&E CCPROP 5' SIDEWALKPROP 5' SIDEWALKPROP 5' SIDEWALKPROPLIGHT(TYP)LODLODLOD LOD LODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LIGHT (TBR)(TYP)LIGHT (TBR)(TYP)LOWLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODDEYE OBJ 440' SDL (35 MPH) LINE OF SIGHT - LEFT 14.5'OBJ 465' SDR (35 MPH) LINE OF SIGHT - R I G H T 19+08.93 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 10+50 11+50 12+50 13+50 14+50 15+50 16+50 17+50 18+50WESNAD8 3 NAD83PROP SIGHT D I S T A N C E PROP SIGHT DISTANCE EASEMENT PROP ROW DATUM ELEV 707.50 SCALE: 1"= 30 ' HORIZONTAL 1"= 3 ' VERTICAL SIGHT DISTANCE PROFILE - COSTELLO DR - ENTRANCE 2 710 715 720 725 730 710 715 720 725 730 10+00710.9710+50711.4711+00711.9011+50712.3212+00713.1212+50713.6613+00714.1713+50714.5714+00715.1714+50715.1115+00716.0415+50716.3016+00717.3216+50718.7017+00720.3217+50721.9018+00723.1618+50724.10EYE 3.5'3.5'OBJ 3.5'OBJ PROP GRADE 440' LINE OF SIGHT - L E F T 465' LINE O F S I G H T - R I G H T May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SGHT-NJA220135.00----->LAYOUT: C-703 SIGHT DISTANCE 2YGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00 JDM GE 04/29/2026 P-CIVL-SGHT 35O3 6,7E3/$1 'O&80E176 PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - 5E9,6,O16 REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-703 6,*+7 ',67$1&E 3/$1$1' 35O),/E 1"=30' 0 307.51530 6,*+7',67$1&E3/$19,E:&O67E//O'5,9EE175$1&E CCCCCCCCCCCCCCPROP 5' SIDEWALKPROP 5' SIDEWALKPROPLIGHT(TYP)LODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LIGHT (TBR)(TYP)LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWEYE OBJ OBJ 465' SDR (35 M P H ) LINE OF SIGHT - RIGHT 440' S D L ( 3 5 M P H) LINE OF S I G H T - L E F T 14.5'WESNAD83NAD8318+97.95 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 10+50 11+50 12+50 13+50 14+50 15+50 16+50 17+50 18+50 PROP SIGHT DISTANCE EASEMENT PROP SIGHT DISTANCE EASEMENT PROP ROW PROP ROW DATUM ELEV 697.50 SCALE: 1"= 30 ' HORIZONTAL 1"= 3 ' VERTICAL SIGHT DISTANCE PROFILE - COSTELLO DR - ENTRANCE 3 700 705 710 715 720 700 705 710 715 720 10+00700.4910+50701.7511+00703.2211+50704.0412+00705.4112+50707.3313+00707.4413+50708.5414+00709.7014+50710.0415+00711.3915+50711.6416+00711.8316+50712.0417+00712.6217+50713.2418+00713.9118+50714.65PROP GRADE EYE 3.5'3.5'OBJ 3.5'OBJ 440' LINE O F S I G H T - L E F T 465' LINE OF SIG H T - R I G H T May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SGHT-NJA220135.00----->LAYOUT: C-704 SIGHT DISTANCE 3YGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00 JDM GE 04/29/2026 P-CIVL-SGHT 35O3 6,7E3/$1 'O&80E176 PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - 5E9,6,O16 REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-704 6,*+7 ',67$1&E 3/$1$1' 35O),/E 1"=30' 0 307.51530 6,*+7',67$1&E3/$19,E:&O67E//O'5,9EE175$1&E CCPROP 5' SIDEWALKLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LO D LO D LO D LO D LO DLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWDDDDDDD14.5'OBJ 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 19+06.30WESNAD83NAD83 PROP SIGHT DISTANCE EASEMENT PROP SIGHT DISTANCE EASEMENT PROP ROW PROP SIGHT DISTANCE EASEMENT DATUM ELEV 690.00 SCALE: 1"= 30 ' HORIZONTAL 1"= 3 ' VERTICAL SIGHT DISTANCE PROFILE - COSTELLO DR - ENTRANCE 4 695 700 705 710 715 720 695 700 705 710 715 720 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 EYE 3.5'3.5'OBJ 465' LINE O F S I G H T - R I G H T APPROXIMATE SURFACE ELEVATION PER FIELD VISIT 3.5'OBJ 440' LINE O F S I G H T - L E F T May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SGHT-NJA220135.00----->LAYOUT: C-705 SIGHT DISTANCE 4YGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00 JDM GE 04/29/2026 P-CIVL-SGHT 35O3 6,7E3/$1 'O&80E176 PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - 5E9,6,O16 REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 C-705 6,*+7 ',67$1&E 3/$1$1' 35O),/E 6,*+7',67$1&E3/$19,E:&O67E//O'5E175$1&E 1"=40' 0 40102040 FRONT ROYAL PIKE - U.S. ROUTE 522STOPSTOPSTOPSTOPSTOPSTOP LOT 1GARBER ESTATE SUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)ZONING: B2N46°13'28"E 367.43'COSTELLO DRIVE 34-1367ELOD LODLOD LOD LOD LOD LODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODWESNORTH ZONEVCS NAD83/2011LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLODLODLODLODLODLODLODLODLODLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOW1.45 ACC=0.85EX-10A0.35 ACC=0.60EX-POND #10.06 ACC=0.90EX-200.20 AC C=0.90EX-180.46 AC C=0.80EX-120.57 AC C=0.80EX-130.29 ACC=0.90EX-13A0.29 ACC=0.90EX-10C0.24 ACC=0.90EX-9B0.17 ACC=0.90EX-111.62 ACC=0.60ST21.72 AC C=0.60ST165'35'60'30'704 705706707708709709708707706705701698699 700 698 699700701702703 706 704 SEDIMENTTRAP 1SEDIMENTTRAP 20.13 ACC=0.90EX-8D0.14 ACC=0.90EX-8E0.20 ACC=0.90EX-150.22 AC C=0.90EX-160.46 ACC=0.85EX-170.09 ACC=0.90EX-140.22 ACC=0.80D-1300.61 ACC=0.60EX-POND #20.64 ACC=0.80EX-230.33 ACC=0.90F-1100.41 ACC=0.80EX-210.10 ACC=0.60EX-220.20 ACC=0.90EX-150.07 ACC=0.90EX-190.10 ACC=0.90EX-5SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSFSSFSSFSSFSSFCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFS0.30 AC C=0.80EX-60.24 ACC=0.90EX-9B0.26 ACC=0.90EX-40.21 ACC=0.85EX-8B0.60 ACC=0.85EX-8C0.45 ACC=0.90EX-10B1.17 ACC=0.85EX-31.22 ACC=0.90EX-10.49 AC C=0.85EX-70.34 ACC=0.80EX-9A0.19 ACC=0.80EX-8ASSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSF 0.33 ACC=0.90F-100712711 7100SCALE:1" = 50'505012.525C-801OVERALLEROSION ANDSEDIMENTCONTROL PLANPHASE 1THIS PLAN TO BE UTILIZED FORSOIL EROSION AND SEDIMENTCONTROL PURPOSES ONLY May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FOR\\BOHLERENG.NET\SHARES\NJ-PROJECTS\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-ERO1-NJA220135.00-0A----->LAYOUT: C-801 OVRL ERO1JM THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-ERO1PROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026C-802C-803 FRONT ROYAL PIKE - U.S. ROUTE 522 TF(TBR)DO NOT ENTERSTOPSTOP STOPSTOP15" RCP(TBR)15" RCP (TBR)15" RC P (TBR)24" RCP(TBR)15" RCP (TBR) 8" PVC (TBR)27" RCP(TBR)27" RCP(TBR)27" RCP(TBR)6" P V C (T B R ) 27" RCP REVE R S E F L O W (TBR)15" RCP42"x27" RCP (TBR)18" RCP (TBR)6" PVC (TBR)STORM MHRIM=725.26(TO BECONVERTEDTO INLET)INV A=721.21INV B=721.16CURB INLET (TBR)RIM=722.45INV=716.20ABCURB INLET (TBR)RIM=717.68INV A=710.78INV B=710.68INV C=710.48INV D=710.38DCABCURB INLET (TBR)RIM=717.82INV A=712.82INV B=712.42ABCURB INLET (TBR)RIM=717.57INV=710.77CURB INLET (TBR)RIM=715.44INV=708.34ABCABCBCACURB INLET (TBR)RIM=712.96INV=705.96CURB INLET (TBR)RIM=716.01INV A=710.26INV B=710.21BAGRATE INLET (TBR)RIM=717.05INV A=715.05INV B=713.55INV C=713.50BACGRATE INLET (TBR)RIM=717.90INV=716.50CURB INLET (TBR)RIM=718.36INV A=712.36INV B=712.16BAGRATE INLET (TBR)RIM=723.28INV=720.53(RECESSED PIPE)MH STORM (TBR)RIM=723.35INV=720.70BOTTOM=±715.9GRATE INLET (TBR)RIM=723.10;BOTTOM=±721.3(RECESSED PIPES)MH STORM (TBR)RIM=723.28INV=720.43BOTTOM=±715.8STOP STOP STOP STOP STOP STOPCOVER(TBR)ICVICV (TBR)GRATE INLET (TBR)RIM=716.74(FULL OF DEBRIS)APPROX. LOC. 30'WATER & SEWEREASEMENTD.B. 838 PG. 1360(TBV)DISPENSERISLAND (TYP)(TBR)GASCOVERS(TYP) (TBR)SHUT OFF SWITCH (TBR)SHUT OFFSWITCH (TBR)ADA SIGN(TBR)ADA SIGN(TYP) (TBR)ADA SIGN(TYP) (TBR)ADA SIGN(TYP) (TBR)ADA SIGN(TYP)(TBR)ADA SIGN(TYP)(TBR)STOPSIGN(TBR)STOPSIGN(TBR)CURB INLET (TBR)RIM=714.74INV A=709.19INV B=709.04INV C=708.84CURB INLET (TBR)RIM=715.75INV A=707.98INV B=707.20INV C=707.15CURB INLET (TBR)RIM=721.42INV A=716.32INV B=716.27VANVANVANVENTPIPES(TBR)CURB INLET (TBR)RIM=713.19INV A=705.59INV B=705.54INV C=705.49COVER (TBR)COSTELLO DRIVE 34-1367EAPPROX. LOC. OFUNDERGROUNDTANKS (TBR)POSSIBLEREVERSE FLOWVANVANVAN VANCOVER (TBR)UNKNOWNSIZE (TBR)PROP. SAWCUTLIMITS OF DISTURBANCE = 12.85 ACLOD LOD LODLODLOD LOD LOD LOD LOD LODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTOTAL LIMITS OF DISTURBANCE = 12.85 ACPROP. SAWCUTPROP.SAWCUTPROP. SAWCUT8" DI P ( T B R ) 8" DI P ( T B R ) 8" D I P ( T B R ) 8" D I P ( T B R ) 8" D I P ( T B R )PROP. SAWCUTPROP. SAWCUTCOSTELLO DRIVE 34-1367EDONOTENTERSIGN(TBR)WESNORTH ZONEVCS NAD83/2011WESNORTH ZONEVCS NAD83/2011WESNORTH ZONEVCS NAD83/2011LIGHT (TBR)(TYP)LIGHT (TBR)(TYP)LIGHT (TBR)(TYP)232.7'98.9'PROP. SAWCUTC/O(TBR)(TYP)LOW HYDRANT (TBR)LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWPAVEMENT MARKINGS (TBR)WALK (TBR)WATERLINE (TBR)TOTAL LIMITS OF DISTURBANCE = 12.85 ACLODLODLODLODLODLODLODLODLODLODLODLODLO D LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOWLOWPROP. SAWCUTLOWLOWPROP.SAWCUTSIGN(TBR)1.45 ACC=0.85EX-10A0.46 AC C=0.80EX-120.57 AC C=0.80EX-130.29 ACC=0.90EX-13A0.29 ACC=0.90EX-10C0.24 ACC=0.90EX-9B0.17 ACC=0.90EX-11IPIP0.13 ACC=0.90EX-8D0.14 ACC=0.90EX-8E0.33 ACC=0.90F-110PROPWASHRACKPROP SETTLING AREA(TO BE CLEANED ATTHE END OF EACH DAY)PROP 9 LF OF 6" HDPE(DRAIN FROMWASHRACK TOSETTLING AREA)0.10 ACC=0.90EX-5CFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSSSFCFSIPIPIPIPIPIPIPIPIPIPIPIPCE0.30 AC C=0.80EX-60.24 ACC=0.90EX-9B0.26 ACC=0.90EX-40.21 ACC=0.85EX-8B0.60 ACC=0.85EX-8C0.45 ACC=0.90EX-10B1.17 ACC=0.85EX-30.49 AC C=0.85EX-70.34 ACC=0.80EX-9A0.19 ACC=0.80EX-8ASSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSF CFSCFSCFS0.33 ACC=0.90F-1000SCALE:1" = 40'40401020C-802EROSION ANDSEDIMENTCONTROL PLANPHASE 1THIS PLAN TO BE UTILIZED FORSOIL EROSION AND SEDIMENTCONTROL PURPOSES ONLY May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FOR\\BOHLERENG.NET\SHARES\NJ-PROJECTS\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-ERO1-NJA220135.00-0A----->LAYOUT: C-802 ERO1JM THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-ERO1PROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - SHEET C-803 SURFACE STABILIZATION MEASURESC-SSM-01 TREE PRESERVATION AND PROTECTIONTPTPPERIMETER CONTROL MEASURESC-PCM-01 SAFETY FENCEC-PCM-04 SILT FENCESAFSFSFSEDIMENT CONTROL MEASURESC-SCM-03 TEMP STONE CONSTRUCTION ENTRANCEC-SCM-04 INLET PROTECTIONCEIPSEQUENCE OF CONSTRUCTION - PHASE I1.CONTRACTOR SHALL NOT COMMENCE ANY LAND DISTURBING ACTIVITIES PRIOR TOPOSTING AN EROSION AND SEDIMENT CONTROL BOND, OBTAINING A LAND DISTURBINGPERMIT, NOTIFYING THE FREDERICK COUNTY INSPECTOR. PRIOR TO HOLDING APRE-CONSTRUCTION MEETING THE LIMITS OF CLEARING AND GRADING SHALL BE FLAGGED.ADDITIONALLY, THE PROJECT ARBORIST AND UFMD MUST BE PRESENT AT THEPRE-CONSTRUCTION MEETING. THE LIMITS OF DISTURBANCE MUST BE WALKED BY THEPROJECT TEAM AND ADJUSTMENTS TO LOD OR PROTECTIVE MEASURES TO BE MADE ATTHAT TIME.2.THE CONTRACTOR SHALL CONTACT FREDERICK COUNTY AT LEAST 48 HOURS PRIOR TOCOMMENCING THE FIRST PHASE OF CONSTRUCTION.3.AREAS WHICH ARE TO BE DISTURBED SHALL BE LIMITED TO DEPICTED LIMITS OF PHASE I,UNLESS OTHERWISE SPECIFICALLY NOTED OR COORDINATED WITH THE FREDERICKCOUNTY INSPECTOR, AND SHALL BE CLEARLY MARKED IN THE FIELD.4.INSTALL PERIMETER CONTROLS, AS DEPICTED WITHIN THE LIMITS OF PHASE I INITIALLIMITS OF CLEARING AND GRADING.5.IF NECESSARY, INSTALL TEMPORARY CONSTRUCTION ENTRANCES, WASH RACKS, ANDSETTLING AREAS WITHIN THE LIMITS OF PHASE I INITIAL LIMITS OF CLEARING ANDGRADING. ALL HARD SURFACES SHALL BE CLEANED AT THE END OF EACH DAY.6.INSTALL REMAINDER OF PERIMETER CONTROLS OUTSIDE OF PHASE I INITIAL LIMITS OFCLEARING AND GRADING. ONCE PERIMETER CONTROLS HAVE BEEN INSTALLED ANDINSPECTED, THE CONTRACTOR MUST COORDINATE WITH THE FREDERICK COUNTYINSPECTOR TO PROCEED WITH CLEARING AND GRADING WITHIN PERIMETER CONTROLS.7.ONCE PERIMETER CONTROLS ARE APPROVED, CONTRACTOR MAY PROCEED WITHDEMOLITION AND ROUGH GRADING ACTIVITIES.8.EROSION AND SEDIMENT CONTROLS ARE TO BE INSPECTED DAILY.NOTE:1.THE FREDERICK COUNTY INSPECTOR SHALL APPROVE THE PHASE I CONTROLS PRIOR TOPHASE II COMMENCING. PERIMETER CONTROLS MAY BE MODIFIED PER CORRESPONDENCEAND APPROVAL OF SITE INSPECTOR.2.THE GRADING/EXCAVATION CONTRACTOR FOR THE SUBJECT SITE IS REQUIRED TO NOTIFY,IN WRITING, THE ASSIGNED SITE INSPECTOR REGARDING ANY EXCESS MATERIALPROPOSED TO BE HAULED OFFSITE PRIOR TO HAULING. THE NOTIFICATIONS MUSTINDICATE THE QUANTITY OF THE MATERIAL TO BE MOVED OFFSITE, IDENTIFICATION OF THERECEIVING SITE WHERE THE EXCESS WILL BE TAKEN AND ALL INFORMATION NECESSARYTO SHOW THAT SUCH RECEIVING SITE HAS BEEN PROPERLY PERMITTED AND HAS E&SCONTROLS INSTALLED.E&S PHASE I NOTES:1.LOD AND PERIMETER CONTROLS ARE SHOWN SEPARATELY FOR GRAPHICALPURPOSES.2.SEE SHEET C-808 FOR EROSION AND SEDIMENT CONTROL DETAILS.3.SUPER SILT FENCE SHALL SERVE AS TREE PROTECTION IN TREE PROTECTION AREAS.CONTRACTOR TO DETERMINE WHERE SUPER SILT FENCE IS NECESSARY.4.CONTRACTOR TO COORDINATE THE LOCATION OF THE CONSTRUCTION ENTRANCE (IFNEEDED) WITH THE SITE INSPECTOR. WITH THE APPROVAL OF SITE INSPECTOR, THEEXISTING ASPHALT CAN BE USED AS A CONSTRUCTION ENTRANCE. 42"x27" RCP (TBR)42"x27" RCP (TBR)18" RCP (TBR)15" RCP (TBR)50"x31" RCP(TBR)15" RCP(TBR)30" RCP (TBR)30" RCP(TBR)15" RCP (TBR)15" DIP (TBR)18" RCP (TBR)18" RCP(TBR)18" RCP(TBR)24" RCP(TBR)15" RCP(TBR)BCACURB INLET (TBR)RIM=712.96INV=705.96CURB INLET (TBR)RIM=711.89INV A=704.09INV B=704.04INV C=703.94ACBCURB INLET (TBR)RIM=711.10INV=704.4ACONC STORMSTRUCTURE (TBR)TOP=708.05INV=699.2515" ORIFICE (TBR)INV=699.98INV=700.98 (TBR)INV=703.15 (TBR)CURB INLET (TBR)RIM=711.28INV=705.78CURB INLET (TBR)RIM=711.17INV A=705.17INV B=705.07INV=704.97INV=703.46INV=705.69 (TBR)CONCSTORMSTRUCTURE(TBR)TOP=709.06INV=703.4112" ORIFICE (TBR)INV=703.58CURB INLET (TBR)RIM=714.66INV A=706.26INV B=706.16BACURB INLET (TBR)RIM=714.60INV A=707.40INV B=707.25CURB INLET (TBR)RIM=717.97INV=713.27GRATE INLET (TBR)RIM=715.07INV A=712.22INV B=712.07CBAABCURB INLET (TBR)RIM=707.39INV A=701.54INV B=701.49BSAN MHRIM=718.19INV=709.94 (TBR)T-PED(TBR)ABABLOT 1GARBER ESTATE SUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)ZONING: B2APPROX. LOC. 30'WATER & SEWER EASEMENT (TBV)D.B. 838 PG. 1360D.B. 838 PG. 1470COSTELLO DR IVE 34 -1367EICV (TBR)COVERS(TBR)COVER(TBR)TRENCH DRAIN (TBR)RIM=717.87(FULL OF DEBRIS)18" RCP (TBR)2xC/O2xC/OGREASETRAP(TBR)VANAPPROX. LOC. 20'WATER EASEMENT (TBV)D.B. 838 PG. 1360D.B. 838 PG. 1470CURB INLET (TBR)RIM=717.32INV A=712.17INV B=711.67INV C=711.52CURB INLET (TBR)RIM=713.19INV A=705.59INV B=705.54INV C=705.49GAS MARKER (TBR)COSTELLO DRIVE 34-1367EPOSSIBLEREVERSE FLOWVANPROP. SAWCUTLOT 1GARBER ESTATESUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)PROP. SAWCUTTOTAL LIMITS OF DISTURBANCE = 12.85 ACCURB INLET (TBR)RIM=702.62INV A = 699.27INV B=695.77TRANSFORMER (TBR)PROP. SAWCUTLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTOTAL LIMITS OF DISTURBANCE = 12.85 ACPROP. SAWCUTPROP. SAWCUTTRENCH DRAIN(TBR)RIM=±715.2(NO ACCESS,UNDERPALLETS/DEBRIS)8" DIP (TBR)8" DIP (TBR)8" DIP (TBR)8" DIP (TBR)8" DIP (TBR)8" DIP (TBR)8" DIP (TBR)8" DIP (TBR)EWESNORTH ZONEVCS NAD83/2011WESNORTH ZONEVCS NAD83/2011LIGHT (TBR)(TYP)LIGHT (TBR) (TYP)HYDRANT (TBR)59.3'INV A=703.68(TBR)WATER (TBR)LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWTOTAL LIMITS OFDISTURBANCE = 12.85 ACLOWLOWLOWLOWLOWLOW0.35 ACC=0.60EX-POND #10.06 ACC=0.90EX-200.20 AC C=0.90EX-180.29 ACC=0.90EX-13A1.62 ACC=0.60ST21.72 AC C=0.60ST165'35'60'30'704 705706707708709709708707706705701698699 700 698 699700 701 702 703 WET STORAGE G 706.00DRY STORAGE G 708.00EMBANKMENTG 711.00WET STORAGE G 700.00DRY STORAGE G 702.00EMBANKMENT G 704.00706 704 SEDIMENTTRAP 1SEDIMENTTRAP 2IP0.20 ACC=0.90EX-150.22 AC C=0.90EX-160.46 ACC=0.85EX-170.09 ACC=0.90EX-140.22 ACC=0.80D-1300.61 ACC=0.60EX-POND #20.64 ACC=0.80EX-230.41 ACC=0.80EX-210.10 ACC=0.60EX-220.20 ACC=0.90EX-150.07 ACC=0.90EX-19SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSFSSFSSFSSFSSFSSFSSFSSFSSFCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSSSFSSFTPTPSSFCFSCFSIPIPIPIPIPIPIPIPIPIP1.17 ACC=0.85EX-31.22 ACC=0.90EX-1PROPWASHRACKPROP SETTLING AREA(TO BE CLEANED ATTHE END OF EACH DAY)PROP 9 LF OF 6" HDPE(DRAIN FROMWASHRACK TOSETTLING AREA)75'15'CEIPCFS712711 7100SCALE:1" = 40'40401020C-803EROSION ANDSEDIMENTCONTROL PLANPHASE 1 May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FOR\\BOHLERENG.NET\SHARES\NJ-PROJECTS\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-ERO1-NJA220135.00-0A----->LAYOUT: C-803 ERO1JM THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-ERO1PROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - SHEET C-802 THIS PLAN TO BE UTILIZED FORSOIL EROSION AND SEDIMENTCONTROL PURPOSES ONLYSURFACE STABILIZATION MEASURESC-SSM-01 TREE PRESERVATION AND PROTECTIONTPTPPERIMETER CONTROL MEASURESC-PCM-01 SAFETY FENCEC-PCM-04 SILT FENCESAFSFSFSEDIMENT CONTROL MEASURESC-SCM-03 TEMP STONE CONSTRUCTION ENTRANCEC-SCM-04 INLET PROTECTIONCEIPSEQUENCE OF CONSTRUCTION - PHASE I1.CONTRACTOR SHALL NOT COMMENCE ANY LAND DISTURBING ACTIVITIES PRIOR TOPOSTING AN EROSION AND SEDIMENT CONTROL BOND, OBTAINING A LAND DISTURBINGPERMIT, NOTIFYING THE FREDERICK COUNTY INSPECTOR. PRIOR TO HOLDING APRE-CONSTRUCTION MEETING THE LIMITS OF CLEARING AND GRADING SHALL BE FLAGGED.ADDITIONALLY, THE PROJECT ARBORIST AND UFMD MUST BE PRESENT AT THEPRE-CONSTRUCTION MEETING. THE LIMITS OF DISTURBANCE MUST BE WALKED BY THEPROJECT TEAM AND ADJUSTMENTS TO LOD OR PROTECTIVE MEASURES TO BE MADE ATTHAT TIME.2.THE CONTRACTOR SHALL CONTACT FREDERICK COUNTY AT LEAST 48 HOURS PRIOR TOCOMMENCING THE FIRST PHASE OF CONSTRUCTION.3.AREAS WHICH ARE TO BE DISTURBED SHALL BE LIMITED TO DEPICTED LIMITS OF PHASE I,UNLESS OTHERWISE SPECIFICALLY NOTED OR COORDINATED WITH THE FREDERICKCOUNTY INSPECTOR, AND SHALL BE CLEARLY MARKED IN THE FIELD.4.INSTALL PERIMETER CONTROLS, AS DEPICTED WITHIN THE LIMITS OF PHASE I INITIALLIMITS OF CLEARING AND GRADING.5.IF NECESSARY, INSTALL TEMPORARY CONSTRUCTION ENTRANCES, WASH RACKS, ANDSETTLING AREAS WITHIN THE LIMITS OF PHASE I INITIAL LIMITS OF CLEARING ANDGRADING. ALL HARD SURFACES SHALL BE CLEANED AT THE END OF EACH DAY.6.INSTALL REMAINDER OF PERIMETER CONTROLS OUTSIDE OF PHASE I INITIAL LIMITS OFCLEARING AND GRADING. ONCE PERIMETER CONTROLS HAVE BEEN INSTALLED ANDINSPECTED, THE CONTRACTOR MUST COORDINATE WITH THE FREDERICK COUNTYINSPECTOR TO PROCEED WITH CLEARING AND GRADING WITHIN PERIMETER CONTROLS.7.ONCE PERIMETER CONTROLS ARE APPROVED, CONTRACTOR MAY PROCEED WITHDEMOLITION AND ROUGH GRADING ACTIVITIES.8.EROSION AND SEDIMENT CONTROLS ARE TO BE INSPECTED DAILY.NOTE:1.THE FREDERICK COUNTY INSPECTOR SHALL APPROVE THE PHASE I CONTROLS PRIOR TOPHASE II COMMENCING. PERIMETER CONTROLS MAY BE MODIFIED PER CORRESPONDENCEAND APPROVAL OF SITE INSPECTOR.2.THE GRADING/EXCAVATION CONTRACTOR FOR THE SUBJECT SITE IS REQUIRED TO NOTIFY,IN WRITING, THE ASSIGNED SITE INSPECTOR REGARDING ANY EXCESS MATERIALPROPOSED TO BE HAULED OFFSITE PRIOR TO HAULING. THE NOTIFICATIONS MUSTINDICATE THE QUANTITY OF THE MATERIAL TO BE MOVED OFFSITE, IDENTIFICATION OF THERECEIVING SITE WHERE THE EXCESS WILL BE TAKEN AND ALL INFORMATION NECESSARYTO SHOW THAT SUCH RECEIVING SITE HAS BEEN PROPERLY PERMITTED AND HAS E&SCONTROLS INSTALLED.E&S PHASE I NOTES:1.LOD AND PERIMETER CONTROLS ARE SHOWN SEPARATELY FOR GRAPHICALPURPOSES.2.SEE SHEET C-808 FOR EROSION AND SEDIMENT CONTROL DETAILS.3.SUPER SILT FENCE SHALL SERVE AS TREE PROTECTION IN TREE PROTECTION AREAS.CONTRACTOR TO DETERMINE WHERE SUPER SILT FENCE IS NECESSARY.4.CONTRACTOR TO COORDINATE THE LOCATION OF THE CONSTRUCTION ENTRANCE (IFNEEDED) WITH THE SITE INSPECTOR. WITH THE APPROVAL OF SITE INSPECTOR, THEEXISTING ASPHALT CAN BE USED AS A CONSTRUCTION ENTRANCE. FRONT ROYAL PIKE - U.S. ROUTE 522 LOT 1GARBER ESTATE SUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)ZONING: B2COSTELLO DRIVE 34-1367ELOD LODLOD LOD LOD LOD LODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODWESNORTH ZONEVCS NAD83/2011LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLODLODLODLODLODLODLODLODLODLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWDSSDDDDDDDDSLC/OC/OC/ODDEE E E E E E E E E DDDDDD0.28 ACC=0.55D-1500.46 AC C=0.80EX-120.57 AC C=0.80EX-130.29 ACC=0.90EX-13A0.17 ACC=0.90EX-110.22 ACC=0.80D-1300.33 ACC=0.90F-110XX ACC=0.60EX-220.20 ACC=0.85A-1330.25 ACC=0.70A-150SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSFSSFSSFSSFSSFCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFS0.37 ACC=0.80D-1400.19 ACC=0.90D-1600.24 ACC=0.90D-1700.11 ACC=0.75D-2100.80 ACC=0.75EX-230.52 ACC=0.65D-1100.36 ACC=0.75C-1600.71 ACC=0.90C-1430.42 ACC=0.65C-1400.17 ACC=0.90C-1130.86 ACC=0.90C-2110.02 ACC=0.85C-2120.16 ACC=0.90C-112A0.31 ACC=0.60D-2200.75 ACC=0.90A-2100.46 ACC=0.90A-2200.73 ACC=0.90A-2300.68 ACC=0.90A-2400.34 ACC=0.85A-1200.18 ACC=0.85A-1210.53 ACC=0.70A-1220.64 ACC=0.90A-1320.90 ACC=0.85A-1310.64 ACC=0.85A-1300.69 ACC=0.85A-1400.27 ACC=0.9RD-20.48 ACC=0.9RD-10.35 ACC=0.9C-1220.15 ACC=0.65B-100A0.12 ACC=0.90C-1110.12 ACC=0.90C-2300.19 ACC=0.90C-2200.17 ACC=0.90C-1210.01 ACC=0.90C-120SSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSF 0.33 ACC=0.90F-100725724723721722718 718719 720720720716717717717718717718719720721722723720721 7147157167177187 1 2 7 1 3 7147147147157 1 6 7 1 7 7 1 0 711712712 713 713711712713714 715716716716716 71 5 7 1 6 7177187 1 9 719 71 9 719 7 1 6 7 1 7718 703 704 705 706 707 708 709 710 71 171171 1 7 1 2 71 3 712 713 714 715 0SCALE:1" = 50'505012.525C-804OVERALLEROSION ANDSEDIMENTCONTROL PLANPHASE 2THIS PLAN TO BE UTILIZED FORSOIL EROSION AND SEDIMENTCONTROL PURPOSES ONLY May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FOR\\BOHLERENG.NET\SHARES\NJ-PROJECTS\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-ERO2-NJA220135.00-0A----->LAYOUT: C-804 OVRL ERO2JM THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-ERO2PROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026C-805C-806 FRONT ROYAL PIKE - U.S. ROUTE 522 COSTELLO DRIVE 34-1367EPROP. SAWCUTLIMITS OF DISTURBANCE = 12.85 ACLOD LOD LODLODLOD LOD LOD LOD LOD LODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTOTAL LIMITS OF DISTURBANCE = 12.85 ACPROP. SAWCUTPROP.SAWCUTPROP. SAWCUTPROP. SAWCUTPROP. SAWCUTCOSTELLO DRIVE 34-1367EWESNORTH ZONEVCS NAD83/2011WESNORTH ZONEVCS NAD83/2011WESNORTH ZONEVCS NAD83/2011232.7'98.9'PROP. SAWCUTLOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWTOTAL LIMITS OF DISTURBANCE = 12.85 ACLODLODLODLODLODLODLODLODLODLODLODLODLO DPROP ROWPROP ROWLOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOWLOWPROP. SAWCUTLOWLOWPROP.SAWCUTPROPLIGHT(TYP)PROPLIGHT(TYP)PROPLIGHT(TYP)PROP UNDG SWM SYSTEM #1ADS STORMTECH CHAMBER SYSTEMSTORAGE VOLUME = 32,414 CFBOTTOM OF CHAMBERS = 704.75'DDVARIABLE STORMDRAINAGE EASEMENTVARIABLE STORMDRAINAGE EASEMENTVARIABLE STORMDRAINAGE EASEMENT0.28 ACC=0.55D-1500.46 AC C=0.80EX-120.57 AC C=0.80EX-130.29 ACC=0.90EX-13A0.17 ACC=0.90EX-11IPIP0.33 ACC=0.90F-110PROPWASHRACKPROP SETTLING AREA(TO BE CLEANED ATTHE END OF EACH DAY)PROP 9 LF OF 6" HDPE(DRAIN FROMWASHRACK TOSETTLING AREA)0.20 ACC=0.85A-1330.25 ACC=0.70A-150CFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSSSFCFS0.37 ACC=0.80D-140CE0.19 ACC=0.90D-1600.24 ACC=0.90D-170IPIPIPIPIPIPIPIPIPIPIPIPIPIPIP0.73 ACC=0.90A-2300.68 ACC=0.90A-2400.34 ACC=0.85A-1200.18 ACC=0.85A-1210.53 ACC=0.70A-1220.64 ACC=0.90A-1320.90 ACC=0.85A-1310.64 ACC=0.85A-1300.69 ACC=0.85A-140SSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSF CFSCFSCFS0.33 ACC=0.90F-100725724723 721 722 7 1 8 7187 1 9 720 720 720 7 1 6 717717717718717 71 8 719 720721722723720721 7147157167177180SCALE:1" = 40'40401020C-805EROSION ANDSEDIMENTCONTROL PLANPHASE 2THIS PLAN TO BE UTILIZED FORSOIL EROSION AND SEDIMENTCONTROL PURPOSES ONLY May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FOR\\BOHLERENG.NET\SHARES\NJ-PROJECTS\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-ERO2-NJA220135.00-0A----->LAYOUT: C-805 ERO2JM THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-ERO2PROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - SHEET C-806 SURFACE STABILIZATION MEASURESC-SSM-01 TREE PRESERVATION AND PROTECTIONTPTPPERIMETER CONTROL MEASURESC-PCM-01 SAFETY FENCEC-PCM-04 SILT FENCESAFSFSFSEDIMENT CONTROL MEASURESC-SCM-03 TEMP STONE CONSTRUCTION ENTRANCEC-SCM-04 INLET PROTECTIONCEIPSEQUENCE OF CONSTRUCTION - PHASE II1.COMMENCE DEMOLITION OF THE EXISTING PAVEMENT, CURB, AND SITE FEATURES ASINDICATED ON THE DEMOLITION PLAN AND AS DEPICTED WITHIN LIMITS OF PHASE II.2.COMMENCE EARTHWORK OPERATIONS AND EXCAVATION FOR CONSTRUCTION OF THEPROPOSED PARKING ADDITIONS.3.COMMENCE CONSTRUCTION OF THE PROPOSED FUEL CANOPY AND FUEL DISPENSERADDITIONS.4.COMMENCE FINE GRADING OF THE SITE WITHIN THE LIMITS OF PHASE II AND COMMENCEINSTALLATION OF CURB AND BASE STONE FOR PAVED AREAS WITHIN THE LIMITS OFPHASE II.5.APPLY PERMANENT SEEDING AND MULCH TO ALL LANDSCAPE AREAS AND NON-PAVEDAREAS. IF REQUIRED FOR CONSTRUCTION PURPOSES, ANY DISTURBED AREAS LOCATEDOUTSIDE THE LIMITS OF PHASE II SHALL BE TEMPORARILY SEEDED.6.COMMENCE INSTALLATION OF COMPACTED SUBBASE. PAVE SITE AND FINAL STABILIZEALL LANDSCAPE AREAS.7.AFTER CONSTRUCTION OPERATIONS HAVE ENDED AND ALL DISTURBED AREAS HAVE BEENSTABILIZED WITH AGREEMENT OF THE FREDERICK COUNTY INSPECTOR, REMOVESEDIMENT CONTROL MEASURES WITHIN 30 DAYS OF FINAL SITE STABILIZATION.8.CONTRACTOR TO REMOVE EXCESS MATERIAL FROM GRADING/EXCAVATION AND DISPOSEOFFSITE AT AN APPROVED FACILITY OR RELOCATE TO A TEMPORARY STOCKPILE AREA OFTHE SUBSEQUENT CONSTRUCTION PHASE UPON INSTALLATION OF PERIMETER E&SCONTROLS FOR THAT RESPECTIVE PHASE. CONTRACTOR TO OBTAIN PERMIT IFREQUIRED FOR OFFSITE HAUL AND DISPOSAL.NOTE:1.FREDERICK COUNTY SITE INSPECTOR MAY MODIFY OR REQUIRE ADDITIONAL CONTROLSAS DEEMED APPROPRIATE BASED ON SITE CONDITIONS.2.THE GRADING/EXCAVATION CONTRACTOR FOR THE SUBJECT SITE IS REQUIRED TONOTIFY, IN WRITING, THE ASSIGNED SITE INSPECTOR REGARDING ANY EXCESS MATERIALPROPOSED TO BE HAULED OFFSITE PRIOR TO HAULING. THE NOTIFICATIONS MUSTINDICATE THE QUANTITY OF THE MATERIAL TO BE MOVED OFFSITE, IDENTIFICATION OFTHE RECEIVING SITE WHERE THE EXCESS WILL BE TAKEN AND ALL INFORMATIONNECESSARY TO SHOW THAT SUCH RECEIVING SITE HAS BEEN PROPERLY PERMITTED ANDHAS E&S CONTROLS INSTALLED.E&S PHASE II NOTES:1.LOD AND PERIMETER CONTROLS ARE SHOWN SEPARATELY FORGRAPHICAL PURPOSES.2.SEE SHEET C-807 FOR EROSION AND SEDIMENT CONTROLDETAILS.3.SUPER SILT FENCE SHALL SERVE AS TREE PROTECTION IN TREEPROTECTION AREAS. CONTRACTOR TO DETERMINE WHERESUPER SILT FENCE IS NECESSARY. LOT 1GARBER ESTATE SUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)ZONING: B2COSTELLO DR IVE 34 -1367ECOSTELLO DRIVE 34-1367EPROP. SAWCUTLOT 1GARBER ESTATESUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)PROP. SAWCUTTOTAL LIMITS OF DISTURBANCE = 12.85 ACPROP. SAWCUTLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTOTAL LIMITS OF DISTURBANCE = 12.85 ACPROP. SAWCUTPROP. SAWCUTEWESNORTH ZONEVCS NAD83/2011WESNORTH ZONEVCS NAD83/201159.3'PROP ROWPROP ROWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWTOTAL LIMITS OFDISTURBANCE = 12.85 ACLOWLOWLOWLOWLOWLOWTPROPTRANSFORMER20' FREDERICK WATER EASEMENT FOR FUTUREWATERMAIN EXTENSION (TYP)PROPTRANSFORMERPROP FLUSH CURBDPROP SHUTOFFVALVEPROP GREASETRAPPROP UNDG SWM SYSTEM #3STORMTRAP OR APPROVED EQUALSTORAGE VOLUME = 49,571 CFSTONE BASE = 697.25BOTTOM OF CHAMBER = 699.00'TOP OF CHAMBER = 704.00'DPROP TRENCH DRAINDDDPROP UNDG SWM SYSTEM #1ADS STORMTECH CHAMBER SYSTEMSTORAGE VOLUME = 32,414 CFSTONE BASE = 704.00'BOTTOM OF CHAMBERS = 704.75'TOP OF SYSTEM = 710.95'DDDDPROP UNDG SWMSYSTEM #2ADS STORMTECHCHAMBER SYSTEMSTORAGEVOLUME = 25,250CFSTONE BASE =703.16'BOTTOM OFCHAMBERS =703.91'TOP OF SYSTEM =709.91'C/OC/OC/OPROP HYDRANT #1DDEE E E E E E E EE E E E E E DDPROPOIL/WATERSEPARATORPROP HYDRANT #3(DEDICATED TO FDC)PROP SANDSEPARATORPROP HYDRANT #2DDDD0.29 ACC=0.90EX-13AIP0.22 ACC=0.80D-130XX ACC=0.60EX-22SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSFSSFSSFSSFSSFSSFSSFSSFSSFCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSSSFSSFTPTPSSFCFSCFSIPIPIPIPIPIPIPIPIPIPIPIPIPIPIPIPIPIP0.11 ACC=0.75D-2100.80 ACC=0.75EX-230.52 ACC=0.65D-1100.36 ACC=0.75C-1600.71 ACC=0.90C-1430.42 ACC=0.65C-1400.17 ACC=0.90C-1130.86 ACC=0.90C-2110.02 ACC=0.85C-2120.16 ACC=0.90C-112A0.31 ACC=0.60D-2200.75 ACC=0.90A-2100.46 ACC=0.90A-2200.73 ACC=0.90A-2300.68 ACC=0.90A-2400.27 ACC=0.9RD-20.48 ACC=0.9RD-10.35 ACC=0.9C-1220.15 ACC=0.65B-100A0.12 ACC=0.90C-111IPIPIP0.12 ACC=0.90C-2300.19 ACC=0.90C-2200.17 ACC=0.90C-1210.01 ACC=0.90C-120PROPWASHRACKPROP SETTLING AREA(TO BE CLEANED ATTHE END OF EACH DAY)PROP 9 LF OF 6" HDPE(DRAIN FROMWASHRACK TOSETTLING AREA)75'15'CECFS714715716717718712 713 714714714715716 717 7 1 0 711712712713713711712713714 715716716716716 71 5 7 1 6 7177187 1 9 719 71 9 719 7 1 6 7 1 7718 703 704 705 706 707 708 709 710 71 171171 1 7 1 2 713 712 713 714 715 0SCALE:1" = 40'40401020C-806EROSION ANDSEDIMENTCONTROL PLANPHASE 2 May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FOR\\BOHLERENG.NET\SHARES\NJ-PROJECTS\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-ERO2-NJA220135.00-0A----->LAYOUT: C-806 ERO2JM THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-ERO2PROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MATCHLINE - SHEET C-805 THIS PLAN TO BE UTILIZED FORSOIL EROSION AND SEDIMENTCONTROL PURPOSES ONLYSURFACE STABILIZATION MEASURESC-SSM-01 TREE PRESERVATION AND PROTECTIONTPTPPERIMETER CONTROL MEASURESC-PCM-01 SAFETY FENCEC-PCM-04 SILT FENCESAFSFSFSEDIMENT CONTROL MEASURESC-SCM-03 TEMP STONE CONSTRUCTION ENTRANCEC-SCM-04 INLET PROTECTIONCEIPSEQUENCE OF CONSTRUCTION - PHASE II1.COMMENCE DEMOLITION OF THE EXISTING PAVEMENT, CURB, AND SITE FEATURES ASINDICATED ON THE DEMOLITION PLAN AND AS DEPICTED WITHIN LIMITS OF PHASE II.2.COMMENCE EARTHWORK OPERATIONS AND EXCAVATION FOR CONSTRUCTION OF THEPROPOSED PARKING ADDITIONS.3.COMMENCE CONSTRUCTION OF THE PROPOSED FUEL CANOPY AND FUEL DISPENSERADDITIONS.4.COMMENCE FINE GRADING OF THE SITE WITHIN THE LIMITS OF PHASE II AND COMMENCEINSTALLATION OF CURB AND BASE STONE FOR PAVED AREAS WITHIN THE LIMITS OFPHASE II.5.APPLY PERMANENT SEEDING AND MULCH TO ALL LANDSCAPE AREAS AND NON-PAVEDAREAS. IF REQUIRED FOR CONSTRUCTION PURPOSES, ANY DISTURBED AREAS LOCATEDOUTSIDE THE LIMITS OF PHASE II SHALL BE TEMPORARILY SEEDED.6.COMMENCE INSTALLATION OF COMPACTED SUBBASE. PAVE SITE AND FINAL STABILIZEALL LANDSCAPE AREAS.7.AFTER CONSTRUCTION OPERATIONS HAVE ENDED AND ALL DISTURBED AREAS HAVE BEENSTABILIZED WITH AGREEMENT OF THE FREDERICK COUNTY INSPECTOR, REMOVESEDIMENT CONTROL MEASURES WITHIN 30 DAYS OF FINAL SITE STABILIZATION.8.CONTRACTOR TO REMOVE EXCESS MATERIAL FROM GRADING/EXCAVATION AND DISPOSEOFFSITE AT AN APPROVED FACILITY OR RELOCATE TO A TEMPORARY STOCKPILE AREA OFTHE SUBSEQUENT CONSTRUCTION PHASE UPON INSTALLATION OF PERIMETER E&SCONTROLS FOR THAT RESPECTIVE PHASE. CONTRACTOR TO OBTAIN PERMIT IFREQUIRED FOR OFFSITE HAUL AND DISPOSAL.NOTE:1.FREDERICK COUNTY SITE INSPECTOR MAY MODIFY OR REQUIRE ADDITIONAL CONTROLSAS DEEMED APPROPRIATE BASED ON SITE CONDITIONS.2.THE GRADING/EXCAVATION CONTRACTOR FOR THE SUBJECT SITE IS REQUIRED TONOTIFY, IN WRITING, THE ASSIGNED SITE INSPECTOR REGARDING ANY EXCESS MATERIALPROPOSED TO BE HAULED OFFSITE PRIOR TO HAULING. THE NOTIFICATIONS MUSTINDICATE THE QUANTITY OF THE MATERIAL TO BE MOVED OFFSITE, IDENTIFICATION OFTHE RECEIVING SITE WHERE THE EXCESS WILL BE TAKEN AND ALL INFORMATIONNECESSARY TO SHOW THAT SUCH RECEIVING SITE HAS BEEN PROPERLY PERMITTED ANDHAS E&S CONTROLS INSTALLED.E&S PHASE II NOTES:1.LOD AND PERIMETER CONTROLS ARE SHOWN SEPARATELY FORGRAPHICAL PURPOSES.2.SEE SHEET C-807 FOR EROSION AND SEDIMENT CONTROLDETAILS.3.SUPER SILT FENCE SHALL SERVE AS TREE PROTECTION IN TREEPROTECTION AREAS. CONTRACTOR TO DETERMINE WHERESUPER SILT FENCE IS NECESSARY. C-807EROSION ANDSEDIMENTCONTROLNOTES ANDDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA220135.00-0A----->LAYOUT: C-807 ERODYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-CNDSPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026EROSION AND SEDIMENT CONTROL MINIMUM STANDARDSMS-1: STABILIZATION - PERMANENT OR TEMPORARY SOIL STABILIZATION WILL BE APPLIED TO DENUDED (BARE SOIL) AREAS WITHIN 7 DAYS AFTER FINAL GRADE ISREACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION WILL BE APPLIED WITHIN 7 DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUTWILL REMAIN DORMANT FOR LONGER THAN 14 DAYS. PERMANENT STABILIZATION WILL BE APPLIED TO AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN 1 YEAR. IFFINAL GRADE IS REACHED ON ANY PORTION OF THE SITE, VEGETATION MUST BE ESTABLISHED TO PREVENT EROSION. BECAUSE GROUND COVER CAN REDUCE EROSIONPOTENTIAL BY MORE THAN 90%, TEMPORARY SEEDING MUST BE APPLIED IF ANY PORTION OF THE SITE WILL REMAIN DORMANT FOR MORE THAN 14 DAYS.MS-2: STOCKPILES, WASTE AND BORROW AREAS - DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILES AND BORROW AREAS WILL BE STABILIZED OR PROTECTEDWITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL STOCKPILESONSITE AS WELL AS BORROW AREAS AND SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE. LOCATIONS OF STOCKPILES AND BORROW PITS SHOULD BEIDENTIFIED ON SITE PLANS, AND STOCKPILES SHOULD HAVE PERIMETER EROSION AND SEDIMENT CONTROL MEASURES INSTALLED AS WELL AS LOCATED WITH ENOUGHSETBACK DISTANCE FROM STREAMS, WATERWAYS, AND ENTRANCES/LINE OF SIGHT. SOIL STOCKPILE SLOPES SHOULD NOT EXCEED 2:1 (HORIZONTAL: VERTICAL). PERMS-1, APPLY TEMPORARY SOIL STABILIZATION (I.E., MULCH, MATTING OR ANNUAL VEGETATION) TO A STOCKPILE WITHIN 7 DAYS IF IT WILL REMAIN DORMANT FOR MORETHAN 14 DAYS. IF THE STOCKPILE WILL REMAIN ONSITE FOR MORE THAN 1 YEAR, STABILIZE IT USING PERMANENT STABILIZATION (I.E., PERMANENT SEEDING MIXES.LANDSCAPING, STONE, TREES). THIS ALSO APPLIES TO OFFSITE BORROW AND SPOIL AREAS. PURPOSE: MULCH PREVENTS EROSION BY PROTECTING THE SURFACE FROMRAINDROP IMPACT, AND SILT FENCE INTERCEPTS AND DETAINS SEDIMENT FROM DISTURBED AREAS.MS-3: PERMANENT VEGETATION - A PERMANENT VEGETATIVE COVER WILL BE ESTABLISHED ON DENUDED AREAS THAT ARE NOT OTHERWISE PERMANENTLY STABILIZED.PERMANENT VEGETATION WILL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT IS UNIFORM, MATURE ENOUGH TO SURVIVE, AND WILLINHIBIT EROSION. SEE C-SSM-10 FOR REQUIREMENTS TO CONSIDER TURF ESTABLISHED. VESCP AND VESMP AUTHORITIES SHOULD VERIFY COMPLIANCE WITH MS-3BEFORE RELEASING A SITE'S BONDS OR SURETY. PURPOSE: REDUCE EROSION AND DECREASE SEDIMENT YIELD FROM DISTURBED AREAS.MS-4: FIRST-STEP MEASURES - SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS, AND OTHER MEASURES INTENDED TO TRAP SEDIMENT WILL BECONSTRUCTED AS A FIRST STEP IN ANY LDA AND WILL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. THIS MS IS MEANT TO ENSURE THATSEDIMENT DOES NOT LEAVE THE PERIMETER OF THE LDA ONCE SITE CLEARING, GRADING, AND CONSTRUCTION COMMENCES. A CERTAIN AMOUNT OF INITIAL LANDDISTURBANCE MAY BE REQUIRED TO PROVIDE ACCESS FOR EQUIPMENT TO INSTALL THE PERIMETER CONTROLS, BUT SITE CLEARING AND GRADING SHOULD BE KEPT TO AMINIMUM UNTIL THE PERIMETER CONTROLS ARE IN PLACE. PURPOSE: INTERCEPT AND DETAIN SMALL AMOUNTS OF SEDIMENT FROM DISTURBED AREAS DURINGCONSTRUCTION TO PREVENT SEDIMENT FROM LEAVING THE SITE AND DECREASE VELOCITY OF SHEET FLOWS AND LOW-TO-MODERATE LEVEL CHANNEL FLOW.MS-5: EARTHEN STRUCTURE STABILIZATION - STABILIZATION MEASURES WILL BE APPLIED TO EARTHEN STRUCTURES, SUCH AS DAMS, DIKES, CHANNELS, AND DIVERSIONS,IMMEDIATELY AFTER INSTALLATION. IN THIS CASE, IMMEDIATE STABILIZATION IS REQUIRED SO THAT THE EARTHEN EROSION AND SEDIMENT CONTROL STRUCTURES THATWERE INSTALLED DO NOT BECOME A SOURCE OF SEDIMENT. EARTHEN STRUCTURES ARE GENERALLY INTENDED TO IMPOUND, CONVEY, OR DIVERT WATER; THEREFORE,IMMEDIATE STABILIZATION IS NEEDED TO PREVENT DAMAGE OR FAILURE OF THE STRUCTURE. PURPOSE: REDUCE EROSION AND SEDIMENTATION AND REDUCE DAMAGEFROM SEDIMENT AND RUNOFF TO DOWNSTREAM OR OFFSITE AREAS.MS-6: TRAPS AND BASINS - SEDIMENT TRAPS AND SEDIMENT BASINS WILL BE DESIGNED AND CONSTRUCTED BASED ON THE TOTAL DRAINAGE AREA TO BE SERVED BY THETRAP OR BASIN. SEDIMENT TRAPS SHOULD BE NOT USED FOR MORE THAN 18 MONTHS UNLESS THEY ARE DESIGNED AS A PERMANENT IMPOUNDMENT. THE MINIMUMSTORAGE CAPACITY OF A SEDIMENT TRAP WILL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA (134 CUBIC YARDS PER ACRE IS EQUIVALENT TO 1 INCH OF RUNOFF),AND THE TRAP WILL ONLY CONTROL DRAINAGE AREAS LESS THAN 3 ACRES. PROVIDE A COMBINATION OF MAN-MADE STORMWATER CONVEYANCE SYSTEM IMPROVEMENT,STORMWATER DETENTION, OR OTHER MEASURES THAT IS SATISFACTORY TO THE VESMP OR VESCP AUTHORITY. SURFACE RUNOFF FROM DISTURBED AREAS THAT ISCOMPOSED OF FLOW FROM DRAINAGE AREAS GREATER THAN OR EQUAL TO 3 ACRES WILL BE CONTROLLED BY A SEDIMENT BASIN. THE MINIMUM STORAGE CAPACITY OF ASEDIMENT BASIN WILL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA. TEMPORARY SEDIMENT BASINS SHOULD BE DESIGNED AND CONSTRUCTED BASEDON THE TOTAL DRAINAGE AREA TO BE SERVED BY THE SEDIMENT BASIN. THE MAXIMUM TOTAL DRAINAGE AREA TO BE SERVED BY A TEMPORARY SEDIMENT BASIN SHOULDBE 100 ACRES. THE OUTFALL SYSTEM WILL, AT A MINIMUM, MAINTAIN THE STRUCTURAL INTEGRITY OF THE BASIN DURING A 25-YEAR STORM OF 24-HOUR DURATION.RUNOFF COEFFICIENTS USED IN RUNOFF CALCULATIONS WILL CORRESPOND TO A BARE EARTH CONDITION OR THOSE CONDITIONSEXPECTED TO EXIST WHILE THE SEDIMENT BASIN IS USED. THE MINIMUM STORAGE CAPACITY OF A TEMPORARY SEDIMENT TRAP SHOULD BE 134 CUBIC YARDS PER ACREOF TOTAL DRAINAGE AREA, HALF OF WHICH SHOULD BE IN THE FORM OF A PERMANENT POOL OR WET STORAGE TO PROVIDE A STABLE SETTLING MEDIUM. THE REMAININGHALF SHOULD BE IN THE FORM OF A DRAWDOWN OR DRY STORAGE TO PROVIDE EXTENDED SETTLING TIME DURING LESS FREQUENT, LARGER STORM EVENTS.CONCENTRATED STORMWATER FLOW FROM A TEMPORARY SEDIMENT BASIN SHOULD BE RELEASED INTO AN ADEQUATE STORMWATER CONVEYANCE SYSTEM.DEMONSTRATE THAT THE TOTAL DRAINAGE AREA AT THE POINT OF DISCHARGE WITHIN THE STORMWATER CONVEYANCE SYSTEM IS AT LEAST 100 TIMES GREATER THANTHE DRAINAGE AREA SERVED BY THE TEMPORARY SEDIMENT BASIN IN QUESTION.MS-7: CUT AND FILL SLOPES - CUT AND FILL SLOPES WILL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION. SLOPES THAT ARE FOUND TO BEERODING EXCESSIVELY WITHIN 1 YEAR OF PERMANENT STABILIZATION WILL BE PROVIDED WITH ADDITIONAL SLOPE STABILIZING MEASURES UNTIL THE PROBLEM ISCORRECTED. CUT AND FILL SLOPES ARE SUSCEPTIBLE TO EROSION DUE TO INCREASED RUNOFF FLOW VELOCITY, SO THEY MUST BE CONSTRUCTED IN THE BEST WAYPOSSIBLE TO DECREASE EROSION BY REDUCING SLOPE LENGTH AND GRADE. PLANS MUST CLEARLY SHOW SLOPE LENGTH AND GRADES THAT WILL REMAIN STABLE. IT ISIMPORTANT THAT SLOPES ARE PROPERLY SEEDED AND MULCHED TO ESTABLISH PERMANENT VEGETATION SO EROSION BY CONCENTRATED FLOW DOES NOT OCCUR.ROUGHENING THE SURFACE OF THE SLOPE CAN ALSO HELP DECREASE RUNOFF BY LOWERING THE VELOCITY OF FLOW AND INCREASING WATER RETENTION, WHICHLEADS TO BETTER SEED GERMINATION. THIS PRACTICE SHOULD GENERALLY BE IMPLEMENTED UNLESS THE SLOPE WILL REQUIRE A HIGH DEGREE OF MAINTENANCEMOWING AFTER VEGETATIVE ESTABLISHMENT.MS-8: CONCENTRATED RUNOFF - CONCENTRATED RUNOFF WILL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY ORPERMANENT CHANNEL, FLUME, OR SLOPE DRAIN STRUCTURE. CONCENTRATED RUNOFF FLOWING DOWN A CUT OR FILL SLOPE WILL CAUSE EROSION; THEREFORE,CONCENTRATED FLOW MUST BE CONTROLLED AT THE OUTLET AND DOWN THE SLOPE THROUGH A TEMPORARY OR PERMANENT CHANNEL, FLUME, OR SLOPE DRAIN. THEENDS OF THESE SLOPE DRAINS NEED OUTLET PROTECTION TO PREVENT EROSION FROM CONCENTRATED FLOWS. CHECK DAMS IN STORMWATER CONVEYANCES ONCUT/FILL SLOPES SHOULD BE USED AT THE TOP AND BOTTOM OF THE SLOPE AND AS NEEDED ALONG THE LENGTH OF THE CHANNEL.MS-9: WATER SEEPS - WHEN WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION WILL BE PROVIDED. CUT AND FILL OPERATIONS MAYEXPOSE SHALLOW AQUIFERS, PERCHED AQUIFERS, OR GROUNDWATER TABLES FROM WHICH WATER MAY SEEP THROUGH THE SIDE OF A SLOPE. THE WATER SEEPS CANCAUSE SLOPES TO ERODE, OR SLOUGH, FROM THE SOIL’S WEIGHT. INTERCEPTION DRAINS SHOULD BE USED TO COLLECT AND SAFELY CONVEY GROUNDWATER AWAYFROM UNSTABLE SLOPES. RIPRAP REVETMENTS OR RETAINING WALL MAY BE USED ON STEEPER SLOPES. THESE AREAS SHOULD BE CLEARLY SHOWN ON THE PLANS ANDTHE SWPPP.MS-10: INLET PROTECTION - ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION WILL BE PROTECTED SO THAT SEDIMENT-LADEN WATERCANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. STORM SEWERS ARE DESIGNED TOEFFICIENTLY TRANSPORT STORMWATER. WHEN SEDIMENTS ENTER THE STORM SEWERS, THE FOLLOWING COULD OCCUR:·WHEN THE VELOCITY OF FLOW IS HIGH, MUCH OF THE SEDIMENT WILL BE QUICKLY TRANSPORTED TO THE NEAREST RECEIVING CHANNEL OR·WHEN THE VELOCITY OF THE FLOW IS LOW, THE SEDIMENT WILL DEPOSIT IN THE PIPES, RESULTING IN CLOGGING AND POTENTIAL FLOODING OF A SITE DURING STORMEVENTS.EITHER OF THESE SCENARIOS CAN CAUSE DETRIMENTAL IMPACTS TO RECEIVING CHANNELS AND AREAS TRIBUTARY TO THE CHANNELS. PROPER INLET PROTECTIONSHOULD BE PLACED AND MAINTAINED DURING ALL LDAS. INLET PROTECTION MAY BE THE OUTFALL FOR THE SITE, AND ADDITIONAL SEDIMENT TRAPPING MEASURES MAYBE NEEDED. INLET PROTECTION CAN BE PROVIDED IN SEVERAL DIFFERENT CONFIGURATIONS. THESE SHOULD BE CLEARLY SHOWN ON THE PLANS AND DESCRIBED IN THESWPPP.MS-11: OUTLET PROTECTION - BEFORE NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS OR PIPES ARE MADE OPERATIONAL, ADEQUATE OUTLETPROTECTION AND ANY REQUIRED TEMPORARY OR PERMANENT CHANNEL LINING WILL BE INSTALLED IN BOTH THE CONVEYANCE CHANNEL AND RECEIVING CHANNEL.OUTLET PROTECTION AND CHANNEL LINING IS A COMPONENT OF MS-5 AS WELL. THESE SHOULD BE CLEARLY SHOWN ON THE PLANS AND DESCRIBED IN THE SWPPP.OUTLET PROTECTION PROVIDES ENERGY DISSIPATION OF THE CONCENTRATED DISCHARGE FROM A PIPE OR CHANNEL TO PREVENT EROSION AND PROVIDE A STABLETRANSITION. TEMPORARY OR PERMANENT CHANNEL LINING HELPS TO ENSURE THAT THE CHANNEL ITSELF WILL NOT ERODE ONCE WATER IS FLOWING THROUGH IT.MS-12: WATERCOURSE CONSTRUCTION - WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS WILL BE TAKEN TO MINIMIZE ENCROACHMENT, CONTROLSEDIMENT TRANSPORT, AND STABILIZE THE WORK AREA TO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NON-ERODIBLE MATERIAL WILL BE USED FOR THECONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USED FOR THESE STRUCTURES IF THEY ARE ARMORED BY NON-ERODIBLE COVER MATERIALS.CHECK DAMS, SILT FENCE, AND OTHER PERIMETER CONTROLS SHOULD NOT BE PLACED ACROSS A LIVE WATERCOURSE. ENSURE THAT PROPER PERMITS (SEE MS-14) AREINCLUDED IN THE SWPPP.MS-13: TEMPORARY VEHICULAR STREAM CROSSING - WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES MORE THAN TWICE IN ANY 6-MONTHPERIOD, A TEMPORARY VEHICULAR STREAM CROSSING CONSTRUCTED OF NON-ERODIBLE MATERIAL WILL BE PROVIDED. WHEN TWO DIFFERENT CONSTRUCTION VEHICLESCROSS A STREAM, ONE RIGHT AFTER THE OTHER, THE STREAM HAS NOW BEEN CROSSED TWICE AND CAN NO LONGER BE CROSSED WITHIN THE NEXT 6 MONTHS WITHOUTVIOLATING THIS MINIMUM STANDARD. THIS MINIMUM STANDARD ALLOWS ONE CONSTRUCTION VEHICLE TO CROSS A STREAM, THEN RETURN WITHIN ANY 6-MONTH PERIODWITHOUT FURTHER TREATMENT; OTHERWISE, A TEMPORARY STREAM CROSSING MUST BE CONSTRUCTED. TEMPORARY VEHICLE CROSSINGS NEED TO BE PROPERLYPERMITTED PER MS-14. TEMPORARY CULVERTS NEED TO BE PROPERLY SIZED PER MS-19. PURPOSE: PROVIDE A MEANS FOR CONSTRUCTION TRAFFIC TO CROSS FLOWINGSTREAMS WITHOUT DAMAGING THE CHANNEL OR BANKS AND KEEP SEDIMENT GENERATED BY CONSTRUCTION TRAFFIC OUT OF THE STREAM.MS-14: OTHER WATERCOURSE REGULATIONS - ALL APPLICABLE FEDERAL, STATE, AND LOCAL REQUIREMENTS PERTAINING TO WORKING IN OR CROSSING LIVEWATERCOURSES WILL BE MET. ACTIVITIES IN LIVE WATERCOURSES USUALLY FALL UNDER THE JURISDICTION OF OTHER AGENCIES AND/OR REGULATIONS INCLUDING:·U.S. ARMY CORPS OF ENGINEERS (404 PERMIT);·VDEQ’S 401 PERMITTING REGULATIONS;·VIRGINIA MARINE RESOURCES COMMISSION (VMRC); AND·VIRGINIA DEPARTMENT OF GAME AND INLAND FISHERIES (DGIF) OR LOCAL WETLAND BOARD TIME OF YEAR RESTRICTIONS.ALL APPLICABLE PERMITS NEED TO BE OBTAINED AND AVAILABLE ONSITE BEFORE CONSTRUCTION IN LIVE WATERCOURSES MAY START. WATER BODIES MAY BEIDENTIFIED THROUGH WETLAND DELINEATION FOLLOWED BY A JURISDICTIONAL DETERMINATION BY THE U.S. ARMY CORPS OF ENGINEERS. WETLANDS, STREAMS, ANDOTHER WATER BODIES AND THE IMPACT ON THESE WATER BODIES ARE USUALLY INDICATED ON PLANS AND SOMETIMES INCLUDE PERMIT NUMBERS.MS-15: BED AND BANK STABILIZATION - THE BED AND BANKS OF A WATERCOURSE WILL BE STABILIZED IMMEDIATELY AFTER WORK IN THE WATERCOURSE IS COMPLETED.STABILIZATION AT THE END OF EACH DAY OR IMMEDIATELY AFTER WORK IS COMPLETED WILL ENSURE THAT SEDIMENT IS NOT IMPACTING OTHER PARTS OF THEWATERCOURSE. PROTECTIVE MEASURES WILL BE NEEDED WHEN WORK CANNOT BE COMPLETED IN A DAY. WHEN WORKING IN WATER, THE SAFETY OF THE WORKERS ANDEQUIPMENT IS IMPORTANT. THE WEATHER ALSO FACTORS IN HEAVILY WHEN DECIDING TO CONTINUE WORKING IN A WATERCOURSE DUE TO POTENTIALLY HIGH FLOWS OFWATER. STABILIZATION MATTING OR ROCK REVETMENT SHOULD BE USED FROM THE WATER LINE TO THE BANK FULL ELEVATION, AND ADDITIONAL MEASURES MAY BENECESSARY UP TO THE 10-YEAR WATER SURFACE ELEVATION. ANY WORK WITHIN A RESOURCES PROTECTION AREA REQUIRES LOCAL APPROVAL.MS-16: UTILITY CONSTRUCTION - UNDERGROUND UTILITY LINES WILL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHERAPPLICABLE CRITERIA:1.NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME.2.EXCAVATED MATERIAL WILL BE PLACED ON THE UPHILL SIDES OF TRENCHES.3.EFFLUENT FROM DEWATERING OPERATIONS WILL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE (OR BOTH) BEFORE BEINGDISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFFSITE PROPERTY.4.MATERIAL USED FOR BACKFILLING TRENCHES WILL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION.5.RE-STABILIZATION WILL BE ACCOMPLISHED IN ACCORDANCE WITH PART V OF THE REGULATION, 9VAC25-875-470 ET SEQ.6.APPLICABLE SAFETY REQUIREMENTS WILL BE MET.THE BASIC PRINCIPLE OF CONTROLLING EROSION AND SEDIMENTATION ON UTILITY PROJECTS IS TO HAVE THE TRENCH BACKFILLED AND STABILIZED AS SOON ASPOSSIBLE. GREATER OPEN TRENCH LENGTHS ARE ALLOWED IF THE PROFESSIONAL ENGINEER SEALS THE DRAWINGS AND PROVIDES A WRITTEN NARRATIVE DESCRIPTIONAND GRAPHICAL DEPICTION OF THE INSTALLATION PROCESS THAT EXPLAINS WHY A LARGER OPEN TRENCH LENGTH IS NECESSARY BASED UPON INSTALLATION PROCESS,PIPE MATERIAL, PIPE DIAMETER, AND SOIL AND SLOPE CHARACTERISTICS. THE PURPOSE IS TO DEMONSTRATE THE MAXIMUM PRACTICABLE OPEN TRENCH LENGTH PERINSTALLATION SPREAD (I.E., LENGTH OF A LINEAR UTILITY BEING INSTALLED BY ONE CREW). LARGE PROJECTS MAY HAVE MULTIPLE “SPREADS” UNDER CONSTRUCTION ATONE TIME.MS-17: VEHICULAR TRACKING AND CONSTRUCTION ENTRANCES - WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONSWILL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED ORPUBLIC ROAD SURFACE, THE ROAD SURFACE WILL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT WILL BE REMOVED FROM THE ROADS BY SHOVELINGOR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING WILL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER.THIS PROVISION WILL APPLY TO INDIVIDUAL DEVELOPMENT LOTS AS WELL AS TO LARGER LDAS. DURING WET WEATHER, CONSTRUCTION TRAFFIC CAN TRANSPORT ASIGNIFICANT AMOUNT OF SEDIMENT (I.E., MUD) ONTO PAVED PUBLIC ROADS, CREATING NOT ONLY A SEDIMENTATION PROBLEM BUT ALSO A SAFETY HAZARD AND PUBLICNUISANCE. MANY JURISDICTIONS HAVE LOCAL ORDINANCES REQUIRING PUBLIC ROADS TO BE KEPT CLEAN, REGARDLESS OF THE APPLICABILITY OF THE EROSION ANDSEDIMENT CONTROL REGULATIONS. THE OPERATOR IS RESPONSIBLE FOR KEEPING PUBLIC ROADS ADJACENT TO THEIR PROJECT CLEAN. MUD SHOULD BE SWEPT ORSHOVELED OFF THE ROAD AND DEPOSITED ON AREAS WHERE IT WILL NOT CAUSE ANOTHER SEDIMENTATION PROBLEM. CONSTRUCTION ROAD STABILIZATION ACCESSINGSTAGING AREAS AND STOCKPILES WILL HELP MINIMIZE SEDIMENT TRANSPORT.MS-18: TEMPORARY CONTROL REMOVAL - ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES WILL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITESTABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE VESMP OR VESCP AUTHORITY. TRAPPEDSEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES WILL BE PERMANENTLY STABILIZED TO PREVENT FURTHEREROSION AND SEDIMENTATION. TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES CAN BECOME A PROBLEM IF LEFT IN PLACE BEYOND THEIRUSEFUL LIFE.·SEDIMENT FENCES CAN TRAP WILDLIFE AND SMALL ANIMALS.·SEDIMENT BASINS CAN BECOME DROWNING HAZARDS OR SOURCES OF SEDIMENT IN CASES OF FAILURE, AND THEY BECOME UNSIGHTLY.TEMPORARY CONTROL MEASURES SHOULD BE REMOVED AS SOON AS THEIR FUNCTION HAS BEEN COMPLETED, AND THE AREA SHOULD BE STABILIZED.MS-19: ADEQUATE STROMWATER CONVEYANCE TO ADEQUATE STORMWATER OUTFALL - PROPERTIES AND WATERWAYS DOWNSTREAM FROM DEVELOPMENT SITES WILLBE PROTECTED FROM SEDIMENT DEPOSITION, EROSION, AND DAMAGE DUE TO INCREASES IN VOLUME, VELOCITY, AND PEAK FLOWRATE OF STORMWATER RUNOFF FORTHE STATED FREQUENCY STORM OF 24-HOUR DURATION. MS-19 OF THE VIRGINIA EROSION AND STORMWATER MANAGEMENT REGULATION (9VAC25-875-560) REQUIRESDESIGNERS TO EVALUATE THE ADEQUACY OF THE DOWNSTREAM ARTIFICIAL AND/OR NATURAL CHANNELS TO SAFELY CONVEY THE DEVELOPED CONDITION RUNOFF. SEESECTION 5.3.2.1 FOR MORE DETAILED INFORMATION ON HOW MS-19 INTERACTS WITH THE STORMWATER QUANTITY REQUIREMENTS. TEMPORARY SEDIMENT BASINS ANDTRAPS SHOULD BE DESIGNED TO DISCHARGE TO A CHANNEL AFTER OUTFALL.EROSION AND SEDIMENT CONTROL NARRATIVEI.PROJECT DESCRIPTION:THE PROPOSED DEVELOPMENT INVOLVES THE DEMOLITION OF THE EXISTING FUEL SERVICE STATION AND RELOCATING THE FUELING TO THE NORTHEAST CORNER OFTHE SITE, A BUILDING ADDITION, REDEVELOPMENT OF THE EXISTING STORMWATER MANAGEMENT BMPS. THE REDEVELOPMENT INCLUDES THE CONSTRUCTION OF APROPOSED 20,709 SF BUILDING ADDITION, 8,400 SF FUELING CANOPY, CURB, LANDSCAPE ISLANDS, UTILITIES, LANDSCAPING, AND ASSOCIATED SITE IMPROVEMENTS ASSHOWN IN THIS SITE PLAN SET. THE AREA OF DISTURBANCE FOR THIS PROJECT IS APPROXIMATELY 12.85 ACRES.II.EXISTING SITE CONDITIONS:THE SITE PARCELS INCLUDE AN EXISTING COSTCO WHOLESALE WAREHOUSE, A FUEL SERVICE STATION ALONG FRONT ROYAL PILE, AND ASSOCIATED PARKING AND SITEFEATURES. THE EXISTING SITE CONTAINS SOME LANDSCAPE ISLANDS WITH SMALL SHRUB PLANTINGS. THE UNDEVELOPED PARCEL TO THE EAST APPREARS TO BE MIXEDOPEN AND NON MAINTAINED GRASS AREAS.III.ADJACENT PROPERTIES:THE SITE IS BORDERED ON THE WEST BY FRONT ROYAL PILE (U.S. ROUTE 552), ON THE SOUTH BY COSTELLO DRIVE, ON THE NORTH BY EXISTING RETAIL USES AND TOTHE EAST BY A PROPERTY OF MAINTAINED ROW CROPS. NO IMPACTS TO ADJACENT PROPERTIES ARE ANTICIPATED. THERE ARE NO WATER BODIES/WETLANDSIMMEDIATELY DOWNSTREAM OR ADJACENT TO THE SITE.IV.OFFSITE AREAS:NO OFF-SITE LAND DISTURBANCE IS ANTICIPATED. PLEASE SEE THE OVERALL SITE, GRADING AND UTILITY PLAN FOR AN OUTLINE OF THE LIMITS OF DISTURBANCE. IFUNSUITABLE SOILS ARE ENCOUNTERED DURING CONSTRUCTION, IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE PROPER METHOD OF DISPOSALAND SUBMIT ANY NECESSARY PLANS TO FREDERICK COUNTY. FURTHERMORE, IF ANY OFFSITE BORROW OR WASTE AREAS ARE NECESSARY, THE CONTRACTOR WILL BERESPONSIBLE FOR THE FINAL STABILIZATION AND MAINTENANCE OF THOSE OFFSITE AREAS. NO ON-SITE STOCKPILE IS AN ANTICIPATED TO BE REQUIRED FORCONSTRUCTION.V.SOILS:NO MARINE CLAYS OR OTHER PROBLEM SOILS ARE KNOWN TO EXIST ON THIS SITE. PER THE SOILS MAPS, THE SUBJECT PROPERTY IS LISTED AS BLAIRTON SILT LOAM.THE CONTRACTOR SHALL REFER TO THE GEOTECHNICAL INVESTIGATION REPORT REFERENCED ON SHEET C-102.VI.CRITICAL EROSION AREAS:NO CRITICAL EROSION AREAS ARE KNOWN TO EXIST ON-SITE.VII.EROSION AND SEDIMENT CONTROL MEASURES:ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL PROTECTION SHALL BE CONSTRUCTED AND MAINTAINED ACCORDING TO THE MINIMUMSTANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (VESCH). THE MINIMUM STANDARDS OF VESCH SHALL BE ADHEREDTO UNLESS OTHERWISE WAIVED OR APPROVED BY A VARIANCE. SPECIFIC EROSION AND SEDIMENT CONTROL MEASURES UTILIZED IN THIS PROJECT INCLUDE THEFOLLOWING:1.TREE PRESERVATION AND PROTECTION C-SSM-01PROTECTING EXISTING TREES AND THEIR ROOT ZONES FROM MECHANICAL AND OTHER INJURY DURING LAND-DISTURBING AND CONSTRUCTION ACTIVITY TOENSURE THE SURVIVAL OF TREES WHERE THEY WILL BE EFFECTIVE FOR EROSION AND SEDIMENT CONTROL AND PROVIDE OTHER ENVIRONMENTAL ANDAESTHETIC BENEFITS.2.TOPSOILING C-SSM-02PRESERVING AND USING TOPSOIL TO PROVIDE A SUITABLE GROWTH MEDIUM FOR VEGETATION USED TO STABILIZE DISTURBED AREAS. APPLICABLE WHEREPRESERVATION OR IMPORTATION OF TOPSOIL IS MOST COST-EFFECTIVE METHOD OF PROVIDING A SUITABLE GROWTH MEDIUM; NOT RECOMMENDED FOR SLOPESSTEEPER THAN 2:1 UNLESS ADDITIONAL MEASURES ARE TAKEN TO PREVENT SLOUGHING AND EROSION.3.SURFACE ROUGHENING C-SSM-03GRADING PRACTICES SUCH AS STAIR-STEPPING OR GROOVING SLOPES OR LEAVING SLOPES IN A ROUGHENED CONDITION BY NOT FINE-GRADING THEM.REDUCES RUNOFF VELOCITY, PROVIDES SEDIMENT TRAPPING, AND INCREASES INFILTRATION, ALL OF WHICH FACILITATE ESTABLISHMENT OF VEGETATION ONEXPOSED SLOPES. APPLICABLE TO ALL STEEP SLOPES THAT HAVE RECEIVED FINAL GRADING BUT WILL NOT BE STABILIZED IMMEDIATELY. ALSO RECOMMENDEDFOR OTHER EXPOSED SLOPES WITH FLATTER GRADES.4.COMPOST BLANKET C-SSM-04A LAYER OF LOOSELY APPLIED COMPOSTED MATERIAL PLACED ON THE SOIL IN DISTURBED AREAS TO REDUCE RUNOFF.5.SOIL STABILIZATION BLANKETS AND MATTING C-SSM-05THE INSTALLATION OF A PROTECTIVE BLANKET OR A SOIL STABILIZATION MAT ON A PREPARED PLANTING OF A STEEP SLOPE, CHANNEL, OR SHORELINE.6.SODDING C-SSM-06STABILIZING FINE-GRADED AREAS BY ESTABLISHING PERMANENT GRASS STANDS WITH SOD. PROVIDES IMMEDIATE PROTECTION AGAINST EROSION AND IS ESPECIALLY EFFECTIVE IN GRASSED SWALES AND WATERWAYS OR IN AREAS WHERE AN IMMEDIATE AESTHETIC EFFECT IS DESIRABLE.7.BERMUDA AND ZOYSIAGRASS ESTABLISHMENT C-SSM-07ESTABLISHMENT OF VEGETATIVE COVER WITH HYBRID BERMUDAGRASS OR ZOYSIAGRASS BY PLANTING SPRIGS, STOLONS, OR PLUGS TO STABILIZE FINE-GRADEDAREAS WHERE ESTABLISHMENT BY SOD IS NOT PREFERRED.8.TREES, SHRUBS, VINES, AND GROUND COVER C-SSM-08STABILIZING DISTURBED AREAS BY PLANTING TREES, SHRUBS, VINES, AND GROUND COVERS WHERE SOD IS NOT PREFERRED. THESE PLANT MATERIALS ALSO PROVIDE FOOD AND SHELTER FOR WILDLIFE AS WELL AS MANY OTHER ENVIRONMENTAL BENEFITS. ESPECIALLY EFFECTIVE WHERE ORNAMENTAL PLANTS ARE DESIRABLE AND TURF MAINTENANCE IS DIFFICULT.9.TEMPORARY SEEDING C-SSM-09ESTABLISHMENT OF TEMPORARY VEGETATIVE COVER ON DISTURBED AREAS THAT WILL NOT BE BROUGHT TO FINAL GRADE FOR PERIODS OF 14 DAYS TO ONE YEAR BY SEEDING WITH APPROPRIATE RAPIDLY GROWING PLANTS.10.PERMANENT SEEDING C-SSM-10ESTABLISHMENT OF PERENNIAL VEGETATIVE COVER BY PLANTING SEED ON ROUGH-GRADED AREAS THAT WILL NOT BE BROUGHT TO FINAL GRADE FOR A YEAROR MORE OR WHERE PERMANENT, LONG- LIVED VEGETATIVE COVER IS NEEDED ON FINE-GRADED AREAS.11.MULCHING C-SSM-11APPLICATION OF PLANT RESIDUES OR OTHER SUITABLE MATERIALS TO DISTURBED SURFACES TO PREVENT EROSION AND REDUCE OVERLAND FLOW VELOCITIES.FOSTERS PLANT GROWTH BY INCREASING AVAILABLE MOISTURE AND PROVIDING INSULATION AGAINST EXTREME HEAT OR COLD. SHOULD BE APPLIED TO ALL SEEDING OPERATIONS, OTHER PLANT MATERIALS WHICH DO NOT PROVIDE ADEQUATE SOIL PROTECTION BY THEMSELVES, AND BARE AREAS WHICH CANNOT BESEEDED DUE TO THE SEASON, BUT WHICH STILL NEED PROTECTION TO PREVENT SOIL LOSS..12.TEMPORARY DIVERSION DIKE C-ECM-04A RIDGE OF COMPACTED SOIL CONSTRUCTED AT THE TOP OR BASE OF A SLOPING DISTURBED AREA WHICH DIVERTS OFFSITE RUNOFF AWAY FROM UNPROTECTED SLOPES AND TO A STABILIZED OUTLET, OR TO DIVERT SEDIMENT LADEN RUNOFF TO A SEDIMENT TRAPPING SOURCE.13.DIVERSION C-ECM-05A CHANNEL CONSTRUCTED ACROSS A SLOPE WITH A SUPPORTING EARTHEN RIDGE ON THE LOWER SIDE. USED TO INTERCEPT AND DIVERT STORMWATER RUNOFF TO STABILIZED OUTLETS AT NON- EROSIVE VELOCITIES.14.DUST CONTROL C-SCM-01REDUCING SURFACE AND AIR MOVEMENT OF DUST DURING LAND DISTURBANCE, DEMOLITION, OR CONSTRUCTION ACTIVITIES IN AREAS SUBJECT TO DUST PROBLEMS IN ORDER TO PREVENT SOIL LOSS AND REDUCE THE PRESENCE OF POTENTIALLY HARMFUL AIRBORNE SUBSTANCES.15.CONSTRUCTION ROAD STABILIZATIONS C-SCM-02TEMPORARY STABILIZATION OF ACCESS ROADS, SUBDIVISION STREETS, PARKING AREAS AND OTHER TRAFFIC AREAS IMMEDIATELY AFTER GRADING TO REDUCEEROSION CAUSED BY VEHICLES DURING WET WEATHER, AND TO PREVENT HAVING TO REGRADE PERMANENT ROADBEDS BETWEEN INITIAL GRADING AND FINALSTABILIZATION.16.TEMPORARY STONE CONSTRUCTION ENTRANCE C-SCM-03A STONE PAD, LOCATED AT POINTS OF VEHICULAR INGRESS AND EGRESS ON A CONSTRUCTION SITE, TO REDUCE THE SOIL TRANSPORTED ONTO PUBLIC ROADSAND OTHER PAVED AREAS.17.STORM DRAIN INLET PROTECTION C-SCM-04THE INSTALLATION OF VARIOUS KINDS OF SEDIMENT TRAPPING MEASURES AROUND DROP INLETS OR CURB INLET STRUCTURES PRIOR TO PERMANENT STABILIZATION OF THE DISTURBED AREA. NOT INTENDED TO CONTROL LARGE, CONCENTRATED FLOWS.18.CULVERT INLET PROTECTION C-SCM-05A SEDIMENT FILTER LOCATED AT THE INLET TO STORM SEWER CULVERTS WHICH PREVENTS SEDIMENT FROM ENTERING, ACCUMULATING IN, AND BEING TRANSFERRED BY THE CULVERT.19.ROCK CHECK DAMS C-SCM-07AN EROSION-RESISTANT GROUND COVER OF LARGE, LOOSE, ANGULAR STONE WITH FILTER FABRIC OR GRANULAR UNDERLINING.20.TEMPORARY SEDIMENT TRAP C-SCM-11A SMALL PONDING AREA, FORMED BY CONSTRUCTING AN EARTHEN EMBANKMENT WITH A STONE OUTLET ACROSS A DRAINAGE SWALE, TO DETAIN SEDIMENT-LADEN RUNOFF FROM SMALL, DISTURBED AREAS FOR ENOUGH TIME TO ALLOW MOST OF THE SUSPENDED SOLIDS TO SETTLE OUT.21.CONCRETE WASHOUT PIT C-SCM-13A TEMPORARY EXCAVATED OR ABOVEGROUND LINED CONSTRUCTED PIT OR A PREFABRICATED OR FABRICATED CONTAINER WHERE CONCRETE TRUCK MIXERSAND EQUIPMENT CAN BE WASHED AFTER THEIR LOADS HAVE BEEN DISCHARGED, TO PREVENT HIGHLY ALKALINE RUNOFF FROM ENTERING STORM DRAINAGE SYSTEMS OR LEACHING INTO SOIL.22.SAFETY FENCE C-PCM-01A PROTECTIVE BARRIER INSTALLED TO PROHIBIT UNDESIRABLE USE OF AN EROSION CONTROL MEASURE.23.STRAW BALE BARRIER C-PCM-02A TEMPORARY SEDIMENT BARRIER COMPOSED OF STRAW BALES PLACED ACROSS OR AT THE TOE OF A SLOPE TO INTERCEPT AND DETAIN SEDIMENT AND DECREASE FLOW VELOCITIES FROM DRAINAGE AREAS OF LIMITED SIZE; APPLICABLE WHERE SHEET AND RILL EROSION MAY BE A PROBLEM.24.SILT FENCE C-PCM-04A TEMPORARY SEDIMENT BARRIER CONSTRUCTED OF POSTS, FILTER FABRIC AND, IN SOME CASES, A WIRE SUPPORT FENCE, PLACED ACROSS OR AT THE TOE OFA SLOPE OR IN A MINOR DRAINAGE WAY TO INTERCEPT AND DETAIN SEDIMENT AND DECREASE FLOW VELOCITIES FROM DRAINAGE AREAS OF LIMITED SIZE; APPLICABLE WHERE SHEET AND RILL EROSION OR SMALL CONCENTRATED FLOWS MAY BE A PROBLEM. MAXIMUM EFFECTIVE LIFE OF 6 MONTHS.25.COMPOST FILTER SOCK C-PCM-05COMPOST FILTER SOCK, ALSO CALLED A FILTER LOG, CONSISTS OF A BIODEGRADABLE OR PHOTODEGRADABLE MESH TUBE FILLED WITH A COARSE COMPOST MEDIA TO FILTER SEDIMENT AND OTHER POLLUTANTS.VIII.MAINTENANCE PROGRAM:1.SILT FENCE SHALL BE INSPECTED AT THE END OF EACH DAY AND AFTER EACH RAINFALL. ANY REQUIRED REPAIRS OR REPLACEMENTS SHALL BE DONE IMMEDIATELY.SEDIMENT DEPOSITS SHALL BE REMOVED BY HAND AFTER EACH RAINFALL AND AT ANY TIME DEPOSITS REACH HALF THE HEIGHT OF THE BARRIER.2.INLET PROTECTIONS SHALL BE INSPECTED AT THE END OF EACH DAY AND AFTER EACH RAINFALL. ANY REQUIRED REPAIRS SHALL BE DONE IMMEDIATELY.3.ALL SEEDED AREAS SHALL BE CHECKED REGULARLY TO ENSURE THAT A GOOD STAND IS MAINTAINED. AREAS SHOULD BE FERTILIZED AND RESEEDED AS NEEDED.4.PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN (7) DAYS AFTER FINAL GRADE IS REACHED ON ANYPORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN (7) DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUTWILL REMAINDORMANT FOR MORE THAN 30 DAYS.5.NO UNPROTECTED, UNDISTURBED AREA SHALL DRAIN TO ROADWAY PAVEMENTS SUCH THAT THE SUBBASE, BASE OR WEARING SURFACES ARE CONTAMINATED BYSILT TRAPPED AT LOW POINTS OR INLETS.6.ADJACENT ROADWAYS AND ENTRANCES WILL BE KEPT CLEAN FROM ACCUMULATED DEBRIS AT ALL TIMES.IX.PERMANENT STABILIZATION:TEMPORARY AND FINAL SEEDING WILL BE PROVIDED IN ACCORDANCE TO VESCH REQUIREMENTS THROUGHOUT CONSTRUCTION AS STATED ABOVE.X.STORMWATER RUNOFF CONSIDERATIONS:1.THE MAJORITY OF THE RUNOFF WILL BE CAPTURED IN CURB INLETS ON THE EXISTING COSTCO PROPERTY AND ROUTED THROUGH A SERIES OF EXISTING STORMPIPES TO THE EXISTING STORM SYSTEM. ONCE THE PROPOSED CONVEYANCE SYSTEM AND UNDERGROUND DETENTION IS INSTALLED THE STORMWATER WILL BECONVEYED TO AND DETAINED AT THE PROPOSED LOCATIONS.XI.CALCULATIONS:1.A STORMWATER BMP IS REQUIRED FOR THIS SITE. CALCULATIONS FOR THE PROPOSED BMP FACILITY ARE PROVIDED ON SHEET C-806.XII.GENERAL LAND CONSERVATION NOTES:1.NO DISTURBED AREA WHICH IS NOT ACTIVELY BEING WORKED SHALL REMAIN DENUDED FOR MORE THAN 14 CALENDAR DAYS UNLESS OTHERWISE AUTHORIZED BYTHE DIRECTOR.2.ALL E&S CONTROL MEASURES APPROVED WITH THE PHASE ONE E&S CONTROL PLAN SHALL BE PLACED AS THE FIRST STEP IN GRADING.3.ALL STORM AND SANITARY SEWER LINES NOT IN STREETS SHALL BE SEEDED AND MULCHED WITHIN 14 DAYS AFTER BACKFILL. NO MORE THAN 500 FEET SHALL BEOPEN AT ANY ONE TIME.4.ELECTRIC POWER, TELEPHONE AND GAS SUPPLY TRENCHES SHALL BE COMPACTED, SEEDED AND MULCHED WITHIN 14 DAYS AFTER BACKFILL.5.ALL TEMPORARY EARTH BERMS, DIVERSIONS AND SEDIMENT CONTROL DAMS SHALL BE SEEDED AND MULCHED FOR TEMPORARY VEGETATIVE COVER IMMEDIATELY(AS SOON AS POSSIBLE BUT NO LATER THAN 48 HOURS) AFTER COMPLETION OF GRADING. STRAW OR HAY MULCH IS REQUIRED. ALL SOIL STOCKPILES SHALL BESEEDED ANDMULCHED WITHIN 14 DAYS AFTER GRADING.6.DURING CONSTRUCTION, ALL STORM SEWER INLETS SHALL BE PROTECTED BY SEDIMENT TRAPS, MAINTAINED AND MODIFIED DURING CONSTRUCTION PROGRESSAS REQUIRED.7.ANY DISTURBED AREA NOT PAVED, SODDED OR BUILT UPON BY NOV. 1, OR DISTURBED AFTER THAT DATE, SHALL BE MULCHEDIMMEDIATELY WITH HAY OR STRAWMULCH AT THE RATE OF 2 TONS/ACRE AND OVER-SEEDED BY APRIL 15.8.AT THE COMPLETION OF ANY PROJECT CONSTRUCTION AND PRIOR TO BOND RELEASE, ALL TEMPORARY SEDIMENT CONTROLS SHALL BE REMOVED AND ALLDENUDED AREAS SHALL BE STABILIZED.XIII.OTHER IMPORTANT NOTES:1.ALL AREAS TO BE PAVED MAY BE STABILIZED BY INSTALLATION OF BASE AND SUBBASE MATERIALS INSTEAD OF TEMPORARY VEGETATION COVER.2.THE CONTRACTOR SHALL PROVIDE ADEQUATE MEANS OF CLEANING MUD FROM TRUCKS AND/OR OTHER EQUIPMENT PRIOR TO ENTERING THE PUBLICRIGHT-OF-WAY. ITIS THE CONTRACTOR'S RESPONSIBILITY TO CLEAR THE STREETS AND TAKE WHATEVER MEASURES NECESSARY TO ENSURE THAT THE STREETSARE MAINTAINED IN A CLEAN AND DUST-FREE CONDITION AT ALL TIMES.3.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PERFORM THE WORK IN SUCH A MANNER AS TO PREVENT THE WASHING OF ANY TOPSOIL OR DEBRIS INTOADJACENT PROPERTIES.4.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO HAVE AND MAINTAIN A WATER TRUCK ON SITE AT ALL TIMES FOR THE PURPOSE OF WASHING CONSTRUCTIONVEHICLES AT THE STONE CONSTRUCTION ENTRANCE PRIOR TO THEIR ENTERING THE RIGHT-OF-WAY. SEDIMENT LADEN RUNOFF SHALL BE DIRECTED AWAY FROMTHE RIGHT-OF-WAY AND TOWARDS AN EROSION AND SEDIMENT CONTROL DEVICE PRIOR TO DISCHARGE INTO THE PUBLIC STORM SYSTEM.5.BORROW OR HAUL (IF REQUIRED) SHALL BE FROM AN APPROVED OFFSITE LOCATION. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL RELATED PERMITS.6.IF GROUNDWATER IS ENCOUNTERED DURING CONSTRUCTION, GROUNDWATER AND SOIL SHALL BE DISPOSED OF IN A MANNER WHICH DOES NOT SPILL ONTOEXISTING PAVEMENT AND CLOG EXISTING INLETS.7.SOIL STOCKPILE IS NOT ANTICIPATED FOR THIS PROJECT. EXCESS SOIL WILL BE HAULED FROM THE SITE.TEMPORARY SEEDINGCONSTRUCTION SPECIFICATIONS FOR TEMPORARY SEEDINGPLANT SELECTION:SELECT PLANTS APPROPRIATE TO THE SEASON AND SITE CONDITIONS FROM TABLE C-SSM-09-3 AND TABLE C-SSM-09-4. NOTE THAT TABLE C-SSM-09-3 PRESENTS PLANTSTHAT CAN BE USED WITHOUT EXTENSIVE EVALUATION OF SITE CONDITIONS; TABLE C-SSM-09-4 PRESENTS MORE IN- DEPTH INFORMATION ON THE PLANT MATERIALS.SEEDBED PREPARATION:TO CONTROL EROSION ON BARE SOIL SURFACES, PLANTS MUST BE ABLE TO GERMINATE AND GROW. GOOD SEEDBED PREPARATION IS ESSENTIAL TO SUCCESSFUL PLANTESTABLISHMENT. A GOOD SEEDBED IS LOOSE AND UNIFORM, WITH AT LEAST 35 PERCENT SOIL-SIZED PARTICLES (<2MM). WHERE HYDROSEEDING METHODS ARE USED, THESURFACE MAY BE LEFT WITH A MORE IRREGULAR SURFACE OF LARGE CLODS AND STONES. MINIMIZE STEEP SLOPES BECAUSE STEEP SLOPES CHALLENGE SEEDBEDPREPARATION AND INCREASE THE EROSION HAZARD.LIMING:DETERMINE IF LIME IS NECESSARY FOR TEMPORARY SEEDING. IN MOST SOILS, IT MAY TAKE SEVERAL MONTHS FOR A PH ADJUSTMENTS TO FULLY OCCUR FOLLOWING THEAPPLICATION OF LIME. THEREFORE, IT MAY BE DIFFICULT TO JUSTIFY THE COST OF LIMING A TEMPORARY SITE, ESPECIALLY WHEN THE SOIL WILL LATER BE MOVED ANDREGRADED. TABLE C-SSM-09-2 MAY BE USED TO DETERMINE THE ACTUAL NEED ALONG WITH SUGGESTED APPLICATION RATES IF THE SOIL PH IS KNOWN. IF THE PH OF THESOIL IS NOT KNOWN, AN APPLICATION OF GROUND AGRICULTURAL LIMESTONE AT THE RATE OF 1 TO 1.5 TONS PER ACRE ON COARSE-TEXTURED SOILS AND 2 TO 3 TONSPER ACRE ON FINE- TEXTURED SOILS IS USUALLY SUFFICIENT. APPLY LIMESTONE UNIFORMLY AND INCORPORATE INTO THE TOP 4 TO 6 INCHES OF SOIL. SOILS WITH A PHOF 6 OR HIGHER NEED NOT BE LIMED. HOWEVER, ANY SOIL WITH A PH OF 5.5 SHOULD RECEIVE LIME APPLICATION. ALL LIMING MATERIALS SHOULD BE VIRGINIADEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES (VDACS) CERTIFIED AGRICULTURAL LIMESTONE OR OTHER APPROVED LIMING PRODUCTS BASED ON THEIRCALCIUM CARBONATE EQUIVALENT.FERTILIZER:APPLY FERTILIZER AT A RATE OF 600 POUNDS PER ACRE (14 POUNDS PER 1,000 SQUARE FEET) USING 10-20-10 FERTILIZER OR EQUIVALENT NUTRIENTS. INCORPORATE LIMEAND FERTILIZER INTO THE TOP 4 TO 6 INCHES OF THE SOIL IF POSSIBLE. IF A HYDRAULIC SEEDER IS USED, DO NOT MIX SEED AND FERTILIZER MORE THAN 30 MINUTESBEFORE APPLICATION.SURFACE ROUGHENING:IF THE AREA HAS BEEN RECENTLY LOOSENED OR DISTURBED, NO FURTHER ROUGHENING IS REQUIRED. WHEN THE AREA IS COMPACTED, CRUSTED, OR HARDENED,LOOSEN THE SOIL SURFACE BY DISCING, RAKING, HARROWING, OR OTHER ACCEPTABLE MEANS ACCORDING TO SURFACE ROUGHENING (BMP C-SSM-03).TRACKING:TRACKING WITH BULLDOZER CLEATS IS MOST EFFECTIVE ON SANDY SOILS. THIS PRACTICE OFTEN CAUSES UNDUE COMPACTION OF THE SOIL SURFACE, ESPECIALLY INCLAYEY SOILS, AND DOES NOT AID PLANT GROWTH AS EFFECTIVELY AS OTHER METHODS OF SURFACE ROUGHENING.SEEDING:EVENLY APPLY SEED WITH A BROADCAST SEEDER, DRILL, CULTIPACKER SEEDER, OR HYDROSEEDER. PLANT SMALL GRAINS NO MORE THAN 1.5 INCHES DEEP. PLANT SMALLSEEDS, SUCH AS KENTUCKY BLUEGRASS, NO MORE THAN 0.25 INCH DEEP. PLANT OTHER GRASSES AND LEGUMES BETWEEN 0.25 INCH TO 0.5 INCH DEEP.MULCHING:MULCH SEEDINGS MADE IN FALL FOR WINTER COVER AND DURING HOT AND DRY SUMMER MONTHS ACCORDING TO MULCHING (BMP C-SSM-11) EXCEPT THOSE OFHYDRO-MULCH (FIBER MULCH), WHICH ARE NOT CONSIDERED ADEQUATE (>70% VEGETATIVE COVER) FOR MID-WINTER OR MID- SUMMER SEEDINGS. USE STRAW MULCHDURING THESE PERIODS. TEMPORARY SEEDINGS MADE UNDER FAVORABLE SOIL AND SITE CONDITIONS DURING OPTIMUM SPRING AND FALL SEEDING DATES MAY NOTREQUIRE MULCH.RESEEDING:AREAS THAT FAIL TO ESTABLISH VEGETATIVE COVER ADEQUATE TO PREVENT RILL EROSION WILL BE RESEEDED AS SOON AS SUCH AREAS ARE IDENTIFIED. DO NOT MOW.PROTECT FROM TRAFFIC AS MUCH AS POSSIBLE.TABLE C-SSM-09-2 LIMINGLIMING REQUIREMENTS FOR TEMPORARY SITESPH TESTRECOMMENDED APPLICATION OF AGRICULTURAL LIMESTONEBELOW 4.23 TONS PER ACRE4.2 TO 5.22 TONS PER ACRE5.2 TO 61 TON PER ACRETABLE C-SSM-09-3 PLANT MATERIAL FOR TEMPORARY SEEDINGACCEPTABLE TEMPORARY SEEDING PLANT MATERIALS "QUICK REFERENCE FOR ALL REGIONS"PLANTING DATESSPECIESRATE (POUNDS PER ACRE)SEPT. 1 - FEB. 1550/50 MIX OF ANNUAL RYEGRASS (LOLIUM MULTI-FLORUM)50 - 100& CEREAL (WINTER) RYE (SECALE CEREALE)FEB. 16 - APR. 30*ANNUAL RYEGRASS (LOLIUM MULTI-FLORUM)60 - 100MAY 1* - AUG. 31GERMAN MILLET (SETARIA ITALICA)50* THIS SHIFT DATE FOR ANNUAL RYE TO GERMAN MILLET SHOULD BE APRIL 15 FOR THE PIEDMONT AND COASTAL PLAIN, AFTER MAY 1.TABLE C-SSM-09-4 TEMPORARY SEEDING APPLICATIONSTEMPORARY SEEDING PLANT MATERIALS, SEEDING RATE, AND DATESSPECIESSEEDING RATENORTH(a)SOUTH(b)PLANT CHARACTERISTICSLBS./ACRELBS./1,000 SF3/1-4/305/1-8/158/15-4/302/15-4/305/1-9/19/1-11/15OATS (AVENA SATIVA)50-1002.0X--X--USE SPRING VARIETIES (EG, NOBLE)RYE(d) (SECALE CEREALE)50-1102.5X-XX-XUSE FOR LATE FALL SEEDINGS,WINTER COVER. TOLERATES COLDAND LOW MOISTURE.GERMAN MILLET501.0-X*--X*-WARM-SEASON ANNUAL. DIES AT(SETARIA ITALICA)FIRST FROST. MAY BE ADDED TOSUMMER MIXES.ANNUAL RYEGRASS(c) 601.5X*-XX*-XMAY BE ADDED IN MIXES. WILL MOW(LOLIUM MULTI-FLORUM)OUT OF MOST STANDS.KOREAN LESPEDEZA (c)251.5XX-XX-WARM-SEASON ANNUAL LEGUME.(LESPEDEZATOLERATES ACID SOILS. MAY ONLYSTIPULACEA)BE USED IN A MIX WITH ANOTHERGRASS (EG, ANNUAL OR CEREALRYE); IT IS NOT SUITABLE AS A PURESEEDING FOR THIS PURPOSE.(a) NORTHERN PIEDMONT AND MOUNTAIN REGIONS. SEE FIGURE C-ENV-01-1 AND FIGURE C-ENV-01-2.(b) SOUTHERN PIEDMONT AND COASTAL PLAIN.(c) MAY BE USED AS A COVER CROP WITH SPRING SEEDING.(d) MAY BE USED AS A COVER CROP WITH FALL SEEDING.(X) MAY NOT BE PLANTED BETWEEN THESE DATES.(-)MAY BE PLANTED BETWEEN THESE DATES.* THE SHIFT DATE FOR ANNUAL RYE TO GERMAN MILLET SHOULD BE APRIL 15 FOR THE PIEDMONT AND COASTAL PLAIN, RATHER THAN MAY 1. C-808EROSION ANDSEDIMENTCONTROLNOTES ANDDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA220135.00-0A----->LAYOUT: C-808 ERODYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-CNDSPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MULCHINGCONSTRUCTION SPECIFICATIONS FOR ORGANIC MULCHESCRITERIA:ORGANIC MULCHES MAY BE USED IN ANY AREA WHERE MULCH IS REQUIRED, SUBJECT TO THE RESTRICTIONS NOTED IN TABLE C-SSM-11-5. ORGANIC MULCHES AREEFFECTIVE WHERE THEY CAN BE TACKED SECURELY TO THE SURFACE OF THE SOIL.MATERIALS:SELECT MATERIALS BASED ON SITE REQUIREMENTS, AVAILABILITY OF MATERIALS, AND AVAILABILITY OF LABOR AND EQUIPMENT. TABLE C-SSM-11-5 LISTS THE MOST USEDORGANIC MULCHES. OTHER MATERIALS, SUCH AS PEANUT HULLS AND COTTON BURS, MAY BE USED WITH THE PERMISSION OF THE CERTIFIED PLAN REVIEWER.PRIOR TO MULCHING:BEFORE MULCHING, COMPLETE THE REQUIRED GRADING AND INSTALL NECESSARY SEDIMENT CONTROL PRACTICES. APPLY LIME AND FERTILIZER SEED AND COMPLETESURFACE ROUGHENING AS NEEDED BEFORE MULCHING EXCEPT IN THE FOLLOWING CIRCUMSTANCES. SEED IS APPLIED AS PART OF A HYDROSEEDER SLURRYCONTAINING WOOD FIBER MULCH. A HYDROSEEDER SLURRY IS APPLIED OVER STRAW.APPLICATION:SPREAD MULCH MATERIALS UNIFORMLY BY HAND OR MACHINE. WHEN SPREADING STRAW MULCH BY HAND, DIVIDE THE AREA TO BE MULCHED INTO APPROXIMATELY1,000-SQUARE-FOOT SECTIONS AND PLACE 70 TO 90 POUNDS (1.5 TO 2 BALES) OF STRAW IN EACH SECTION TO FACILITATE UNIFORM DISTRIBUTION. AFTER SPREADINGMULCH, ENSURE NO MORE THAN 25% OF THE GROUND IS VISIBLE. WHEN USING A HYDROSEEDER, CONFIRM THE USE OF A GREEN DYE TO ENSURE THE SEED IS SPREADUNIFORMLY ACROSS THE GROUND.STRAW MULCH MUST BE ANCHORED IMMEDIATELY AFTER SPREADING TO PREVENT DISPLACEMENT. OTHER ORGANIC MULCHES LISTED IN TABLE C-SSM-11-5 DO NOTREQUIRE ANCHORING. USE THE FOLLOWING METHODS OF ANCHORING STRAW.MULCH ANCHORING SPECIFICATIONSMULCH ANCHORING TOOL:A TRACTOR-DRAWN IMPLEMENT DESIGNED TO PUNCH MULCH INTO THE SOIL SURFACE, OFTEN REFERRED TO AS A KRIMPER OR KRIMPER TOOL. THIS METHOD PROVIDESGOOD EROSION CONTROL WITH STRAW. IT IS LIMITED TO USE ON SLOPES NO STEEPER THAN 3H:1V, WHERE EQUIPMENT CAN OPERATE SAFELY. OPERATE MACHINERYALONG THE CONTOUR.FIBER MULCH:A VERY COMMON PRACTICE WITH WIDESPREAD USE TODAY. APPLY FIBER MULCH BY MEANS OF A HYDROSEEDER AT A RATE OF 500 TO 750 POUNDS PER ACRE ATOPSTRAW MULCH OR HAY. FIBER MULCH HAS AN ADDED BENEFIT OF PROVIDING ADDITIONAL MULCH TO THE NEWLY SEEDED AREA.MULCH NETTINGS:LIGHTWEIGHT PLASTIC, COTTON, OR PAPER NETS MAY BE STAPLED OVER THE MULCH ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.PEG AND TWINE:BECAUSE IT IS LABOR-INTENSIVE, THIS METHOD IS FEASIBLE ONLY IN SMALL AREAS WHERE OTHER METHODS CANNOT BE USED. DRIVE 8- TO 10-INCH WOODEN PEGS 3INCHES INTO THE SOIL SURFACE EVERY 4 FEET IN ALL DIRECTIONS. STAKES MAY BE DRIVEN BEFORE OR AFTER STRAW IS SPREAD.SECURE MULCH BY STRETCHING TWINE BETWEEN PEGS IN A CRISSCROSS-WITHIN-A SQUARE PATTERN. TURN TWINE TWO OR MORE TIMES AROUND EACH PEG.VEGETATION:RYE (GRAIN) MAY BE USED TO ANCHOR THE MULCH IN FALL PLANTINGS AND GERMAN MILLET IN THE SPRING. BROADCAST AT 15 POUNDS PER ACRE BEFORE APPLYINGMULCH.LIQUID MULCH BINDERS:ENSURE APPLICATION OF LIQUID MULCH BINDERS AND TACKIFIERS IS HEAVIEST AT EDGES OF MULCHED AREAS AND AT CRESTS OF RIDGES AND BANKS TO PREVENTDISPLACEMENT. UNIFORMLY APPLY THE BINDER TO THE REMAINDER OF THE AREA. BINDERS MAY BE APPLIED AFTER MULCH IS SPREAD OR MAY BE SPRAYED INTO THEMULCH AS IT IS BEING BLOWN ONTO THE SOIL. STRAW AND BINDER TOGETHER ARE NOTED AS THE MOST EFFECTIVE METHOD.THE FOLLOWING TYPES OF BINDERS MAY BE USED:SYNTHETIC BINDERS: FORMULATED BINDERS OR ORGANICALLY FORMULATED PRODUCTS MAY BE USED AS RECOMMENDED BY THE MANUFACTURER TO ANCHOR MULCH.ASPHALT: ANY TYPE OF ASPHALT THIN ENOUGH TO BE BLOWN FROM SPRAY EQUIPMENT IS SATISFACTORY. USE RAPID-CURING (RC-70, RC-250, RC-800), MEDIUM-CURING (MC-250, MC- 800), AND EMULSIFIED ASPHALT (SS-1, CSS-1, CMS-2, MS-2, RS-1, RS-2, CRS-1, AND CRS-2). APPLY ASPHALT AT 0.1 GALLON PER SQUARE YARD (10 GAL./1000 SQ.FT. OR 430 GAL./ACRE). DO NOT USE HEAVIER APPLICATIONS, AS IT MAY CAUSE THE STRAW TO “PERCH” OVER RILLS. ALL ASPHALT DESIGNATIONS ARE FROM THE ASPHALTINSTITUTE SPECIFICATIONS. IN TRAFFIC AREAS, UNCURED ASPHALT CAN BE PICKED UP ON SHOES AND CAUSE DAMAGE TO THE INDOORS OF BUILDINGS/HOUSES. USE RSOR CRS TYPES TO MINIMIZE ANY POTENTIAL RISK.*NOTE: THIS METHOD IS NOT USED AS COMMONLY AS IT ONCE WAS. THE DEVELOPMENT OF HYDRAULIC SEEDING EQUIPMENT HAS ENCOURAGED THE INDUSTRY TO TURNTO SYNTHETIC OR ORGANICALLY BASED BINDERS AND TACKIFIERS. WHEN THIS METHOD IS USED, ENVIRONMENTAL CONCERNS SHOULD BE ADDRESSED TO ENSURE THATPETROLEUM-BASED PRODUCTS DO NOT ENTER WATER SUPPLIES. AVOID APPLICATIONS INTO WATERWAYS OR CHANNELS.CHEMICAL MULCH SPECIFICATIONSCHEMICAL MULCHES:CHEMICAL MULCHES* MAY BE USED ALONE ONLY IN THE FOLLOWING SITUATIONS:WHERE NO OTHER MULCHING MATERIAL IS AVAILABLE.IN CONJUNCTION WITH TEMPORARY SEEDING WHEN MULCH IS NOT REQUIRED FOR THAT PRACTICE.FROM MARCH 15 TO MAY 1 AND AUGUST 15 TO SEPTEMBER 30, PROVIDED THEY ARE USED ON AREAS WITH SLOPES NO STEEPER THAN 4H:1V THAT HAVE BEEN ROUGHENEDIN ACCORDANCE WITH SURFACE ROUGHENING (C-SSM-03). IF RILL EROSION OCCURS, ANOTHER MULCH MATERIAL WILL BE APPLIED IMMEDIATELY.*NOTE: CHEMICAL MULCHES MAY BE USED TO BIND OTHER MULCHES OR WITH FIBER MULCH IN A HYDROSEEDED SLURRY AT ANY TIME. MANUFACTURER'SRECOMMENDATIONS FOR APPLICATION OF CHEMICAL MULCHES WILL BE FOLLOWED.ORGANIC MULCH MATERIAL AND APPLICATION RATESSTRAW OR HAY:RATE = 1.5 TO 2 TONS PER ACRE OR 70 TO 90 LBS PER 1,000 SFFREE FROM WEEDS AND COARSE MATTER. MUST BE ANCHORED. SPREAD WITH MULCH BLOWER OR BY HAND. USE A MINIMUM OF 2 TONS PER ACRE FOR WINTER COVER.FIBER MULCH:RATE = 1,500 LBS PER ACRE OR 35 LBS PER 1,000 SFDO NOT USE AS MULCH FOR WINTER COVER OR DURING HOT, DRY PERIODS. APPLY AS SLURRY. WHEN FIBER MULCH IS THE ONLY AVAILABLE MULCH DURING PERIODSWHEN STRAW SHOULD BE USED, APPLY AT A MINIMUM RATE OF 2000 LBS./ACRE OR 45 LBS./1,000 SF.CORN STALKS:RATE = 4 TO 6 TONS PER ACRE OR 185 TO 275 LBS PER 1,000 SFCUT OR SHREDDED IN 4- TO 6-INCH LENGTHS. AIR-DRIED. DO NOT USE IN FINE TURF AREAS. APPLY WITH MULCH BLOWER OR BY HAND.WOOD CHIPS:RATE = 4 TO 6 TONS PER ACRE OR 185 TO 275 LBS PER 1,000 SFFREE OF COARSE MATTER. AIR-DRIED. TREAT WITH 12 LBS. NITROGEN PER TON. DO NOT USE IN FINE TURF AREAS. APPLY WITH MULCH BLOWER, CHIP HANDLER, OR BYHAND.BARK CHIPS OR SHREDDED BARK:RATE = 50 TO 70 CY PER ACRE OR 1 TO 2 CY PER 1,000 SFFREE OF COARSE MATTER. AIR-DRIED. DO NOT USE IN FINE TURF AREAS. APPLY WITH MULCH BLOWER, CHIP HANDLER, OR BY HAND.OPERATIONS AND MAINTENANCE CONSIDERATIONSINSPECT ALL MULCHES AND SOIL COVERINGS PERIODICALLY AND AFTER RAINSTORM EVENTS TO CHECK FOR EROSION. WHERE EROSION IS OBSERVED IN MULCHEDAREAS, APPLY ADDITIONAL MULCH. INSPECT NETS AND MATS AFTER RAINSTORMS FOR DISLOCATION OR FAILURE. IF WASHOUTS OR BREAKAGE OCCUR, REINSTALLNETTING OR MATTING AS NECESSARY AFTER REPAIRING DAMAGE TO THE SLOPE OR DITCH. INSPECT MULCHES UNTIL GRASSES ARE FIRMLY ESTABLISHED.WHERE MULCH IS USED IN CONJUNCTION WITH ORNAMENTAL PLANTINGS, INSPECT PERIODICALLY THROUGHOUT THE YEAR (APPROXIMATELY EVERY 3 MONTHS) TODETERMINE IF MULCH IS MAINTAINING COVERAGE OF THE SOIL SURFACE; REPAIR AS NEEDED.PERMANENT SEEDINGCONSTRUCTION SPECIFICATIONS FOR PERMANENT SEEDINGSELECTION OF PLANT MATERIALS:SELECTION OF PLANT MATERIALS IS BASED ON CLIMATE, TOPOGRAPHY, SOILS, LAND USE, AND PLANTING SEASON. TO DETERMINE WHICH PLANT MATERIALS ARE BESTADAPTED TO A SPECIFIC SITE, USE TABLE C-SSM-10-4 AND TABLE C-SSM-10-5, WHICH DESCRIBE PLANT CHARACTERISTICS AND LIST RECOMMENDED VARIETIES. THESPECIES LISTED IN TABLE C-SSM-10-4 TO C-SSM-10-8 ARE NOT EXCLUSIVE AND OTHER SPECIES AND VARIETIES MAY BE SUITABLE FOR USE IN VIRGINIA BASED ONEMERGING RESEARCH BY VDOT AND THE REVEGETATION INDUSTRY. HOWEVER, USE OF AGGRESSIVE OR INVASIVE SPECIES AS IDENTIFIED BY VA DCR WHERE VIABLENATIVE SUBSTITUTES ARE AVAILABLE IS DISCOURAGED. INFORMATION ABOUT INVASIVE SPECIES IS AVAILABLE ON THE DCR WEBSITE. (SEE DCR 2022)SUGGESTED BASIC SEEDING MIXTURES FOR SITE CONDITIONS IN VIRGINIA ARE PROVIDED IN TABLES C-SSM-10-6, C-SSM-10-7, AND C-SSM-10-8. THESE MIXTURES AREDESIGNED FOR GENERAL USE AND HAVE PROVEN TO BE SUCCESSFUL OVER TIME ON TYPICAL SITES. SEE TABLES CSSM- 10-4 AND C-SSM-10-5 FOR RECOMMENDEDVARIETIES. HOWEVER, IT IS STRONGLY SUGGESTED THAT ALL LOW MAINTENANCE SEED MIXTURES CONTAIN AT LEAST TWO DIFFERENT SPECIES OF BOTH GRASSES ANDLEGUMES IN ADDITION TO AN APPROPRIATE SEASONAL COVER SPECIES.MORE EXTENSIVE DESCRIPTIONS OF PLANT MATERIALS (GRASSES AND LEGUMES), THEIR USAGE, AND PICTORIAL REPRESENTATIONS ARE PROVIDED IN TABLE C-SSM-10-1.WHEN USING SOME VARIETIES OF TURF GRASSES, THE VIRGINIA CROP IMPROVEMENT ASSOCIATION (VCIA) RECOMMENDS THAT TURF GRASS MIXTURES MAY ALSO BEUSED. CONSUMER PROTECTION PROGRAMS HAVE BEEN DEVISED TO IDENTIFY QUALITY SEED OF THE VARIETIES RECOMMENDED BY THE VIRGINIA COOPERATIVEEXTENSION SERVICE. THESE WILL BEAR A LABEL INDICATING THAT THEY ARE APPROVED BY THE ASSOCIATION. MIXTURES MAY BE DESIGNED FOR A SPECIFICPHYSIOGRAPHIC REGION OR BASED ON INTENDED USE. SPECIAL CONSIDERATION IS GIVEN TO PLANT CHARACTERISTICS, PERFORMANCE, AND OTHER ATTRIBUTES.SITE PLANNERS AND DESIGNERS SHOULD REFER TO THE DCR INVASIVE SPECIES LIST AS PART OF THE PROCESS OF SELECTING PLANT MATERIALS FOR A SITE. (SEE DCR2022). THIS SERVES TWO PURPOSES: TO AVOID USE OF INVASIVE SPECIES TO THE EXTENT POSSIBLE; AND TO ENSURE PLANT SELECTION IS BASED ON THE MOST CURRENTINFORMATION AVAILABLE.SEED QUALITY CRITERIA:WHERE CERTIFIED SEED IS NOT AVAILABLE, USE GRASS AND LEGUME SEED IN VEGETATIVE ESTABLISHMENT THAT MEETS THE MINIMUM REQUIREMENTS AS PROVIDEDBELOW.ENSURE ALL TAGS ON CONTAINERS OF SEED ARE LABELED TO MEET THE REQUIREMENTS OF THE STATE SEED LAW.ENSURE ALL SEED IS SUBJECT TO RE-TESTING BY A RECOGNIZED SEED LABORATORY THAT EMPLOYS A REGISTERED SEED TECHNOLOGIST OR BY A STATE SEED LAB.ENSURE ALL SEED USED HAS BEEN TESTED WITHIN 12 MONTHS.ENSURE THE INOCULANT ADDED TO LEGUME SEED IN THE SEED MIXTURES IS A PURE CULTURE OF NITROGEN-FIXING BACTERIA PREPARED FOR THE SPECIES. DO NOT USEINOCULANTS AFTER THE DATE INDICATED ON THE CONTAINER. USE TWICE THE SUPPLIER’S RECOMMENDED RATE OF INOCULANT ON DRY SEEDINGS; FIVE TIMES THERECOMMENDED RATE IF HYDROSEEDED. DELAY ADDITION OF THE INOCULANT UNTIL NO MORE THAN 30 MINUTES PRIOR TO HYDROSEEDING TO AVOID LOSS OF VIABILITY.ENSURE THE QUALITY OF THE SEED USED IS SHOWN ON THE BAG TAGS TO CONFORM TO THE GUIDELINES DOCUMENTED IN TABLE C-SSM-10-9.ALL SEEDING RATES SHOWN IN TABLES C-SSM-10-4 TO C-SSM-10-9 SHOULD BE APPLIED ON A "PURE LIVE SEED" (PLS) BASIS CALCULATED AS THE SUM OF READILYGERMINABLE AND HARD SEED, BUT NOT INERT MATTER OR OTHER WEEDY SPECIES.SEEDBED REQUIREMENTS:DO NOT ESTABLISH VEGETATION ON SLOPES THAT ARE UNSUITABLE DUE TO INAPPROPRIATE SOIL TEXTURE, POOR INTERNAL STRUCTURE OR INTERNAL DRAINAGE,VOLUME OF OVERLAND FLOW, OR EXCESSIVE STEEPNESS UNTIL THESE PROBLEMS HAVE BEEN CORRECTED. TO MAINTAIN A GOOD STAND OF VEGETATION, ENSURE THESOIL MEETS THE FOLLOWING MINIMUM REQUIREMENTS AS A GROWTH MEDIUM:·SUFFICIENT FINE GRAINED SOIL MATERIAL (> 25% < 2 MM) TO MAINTAIN ADEQUATE SOIL MOISTURE AND NUTRIENT SUPPLY. AREAS THAT DO NOT MEET THISREQUIREMENT WILL REQUIRE TOPSOILING (C-SSM-02) OR APPLICATION OF COMPOST AND/OR MANUFACTURED SOIL MATERIALS TO BE VIABLE;·SUFFICIENT PORE SPACE TO PERMIT ROOT PENETRATION. AN IN SITU SURFACE SOIL BULK DENSITY OF BETWEEN 1.35 G/CM3 (CLAYEY SOILS) AND 1.75 G/CM3 (SANDYSOILS) FOLLOWING SITE PREPARATION AND SOIL AMENDMENT INDICATES SUFFICIENT PORE SPACE FOR WATER HOLDING AND ENHANCED INFILTRATION.;·SUFFICIENT SOIL DEPTH TO PROVIDE AN ADEQUATE ROOT ZONE. ENSURE THE DEPTH TO ROCK OR IMPERMEABLE LAYERS (SUCH AS HARDPANS) IS A MINIMUM OF 12INCHES, EXCEPT ON SLOPES STEEPER THAN 2H:1V, WHERE THE ADDITION OF SOIL IS NOT FEASIBLE;·A FAVORABLE PH RANGE FOR PLANT GROWTH. IF THE SOIL IS SO ACIDIC THAT A PH RANGE OF 6.0 TO 7.0 CANNOT BE ATTAINED BY ADDITION OF PH-MODIFYINGMATERIALS, THEN THE SOIL IS CONSIDERED AN UNSUITABLE ENVIRONMENT FOR PLANT ROOTS, AND FURTHER SOIL MODIFICATION IS REQUIRED;·FREE FROM TOXIC AMOUNTS OF MATERIALS HARMFUL TO PLANT GROWTH; AND·FREE FROM EXCESSIVE QUANTITIES OF ROOTS, BRANCHES, LARGE STONES, LARGE CLODS OF EARTH, OR TRASH OF ANY KIND. CLODS AND STONES MAY BE LEFT ONSLOPES STEEPER THAN 3H:1V IF THEY DO NOT SIGNIFICANTLY IMPEDE GOOD SEED-TO-SOIL CONTACT.IF ANY OF THESE CRITERIA CANNOT BE MET (I.E., IF THE EXISTING SOIL IS TOO COARSE, DENSE, SHALLOW, ACIDIC, OR CONTAMINATED TO FOSTER VEGETATION), APPLYTOPSOIL IN ACCORDANCE WITH TOPSOILING (C-SSM-02).INSTALL THE NECESSARY STRUCTURAL EROSION AND SEDIMENT CONTROL PRACTICES BEFORE SEEDING. CARRY OUT GRADING ACCORDING TO THE APPROVED PLAN.ROUGHEN SURFACES IN ACCORDANCE WITH SURFACE ROUGHENING (C-SSM-03).SOIL CONDITIONERS AND AMENDMENTS AT SEEDING:TO MODIFY THE TEXTURE, STRUCTURE, OR DRAINAGE CHARACTERISTICS OF A SOIL, THE FOLLOWING MATERIALS MAY BE ADDED. ANY PRODUCT LABELED AS A SOILCONDITIONER, HORTICULTURAL GROWING MEDIUM, LIMING MATERIAL OR FERTILIZER IN VA MUST BE APPROVED BY VDACS.PEAT: PEAT IS A VERY COSTLY CONDITIONER BUT WORKS WELL. IF ADDED, USE SPHAGNUM MOSS PEAT, HYPNUM MOSS PEAT, REED-SEDGE PEAT, OR PEAT HUMUS FROMFRESHWATER SOURCES. SHRED AND CONDITION PEAT IN STORAGE PILES FOR AT LEAST 6 MONTHS AFTER EXCAVATION. USE A WETTING AGENT UNLESS AGED PEAT ISAVAILABLE.SAND: USE SAND THAT IS CLEAN AND FREE OF TOXIC MATERIALS. SAND MODIFICATION IS INEFFECTIVE UNLESS ADDED AT A RATE OF 80 TO 90 PERCENT BY VOLUME, WHICHIS EXTREMELY DIFFICULT TO ACHIEVE ONSITE. IF THIS PRACTICE IS CONSIDERED, CONSULT A PROFESSIONAL AUTHORITY TO ENSURE THAT IT IS CONDUCTED PROPERLY.ANIMAL MANURE: ANY APPLICATION OF ANIMAL MANURES MUST FOLLOW APPLICABLE VDEQ WASTE MANAGEMENT REGULATIONS AND MAY BE SUBJECT TO VA DCRNUTRIENT MANAGEMENT PLANNING (NMP) GUIDANCE. FULLY COMPOSTED (PER CRITERIA IN C-SSM-04) MANURE PRODUCTS CAN BE UTILIZED AS SOIL CONDITIONERS WITHINPUT FROM A WASTE MANAGEMENT PROFESSIONAL.ROTTED SAWDUST OR WOOD WASTE MATERIALS: THOROUGHLY ROTTED SAWDUST OR STABILIZED WOOD WASTE MATERIALS THAT IS FREE OF STICKS, STONES AND TOXICMATERIALS MAY BE USED AS A SOIL CONDITIONER, BUT MAY REQUIRE ADDITIONAL N FERTILIZER TO OFFSET HIGH C:N RATIO LIMITATIONS BASED ON INPUT FROM A WASTEMANAGEMENT PROFESSIONAL.BIOSOLIDS: UTILIZATION OF BIOSOLIDS (TREATED SEWAGE SLUDGE) IS A PROVEN BENEFICIAL PRACTICE FOR A WIDE RANGE OF AGRICULTURAL AND DISTURBED LANDREMEDIATION AND REVEGETATION PRACTICES. ALL LAND APPLICATION OF BIOSOLIDS IS REGULATED BY VDEQ ON A PRODUCER X SITE-SPECIFIC APPLICATION BASIS INCONFORMANCE WITH USEPA PART 503 REGULATIONS. CONFORMANCE WITH DCR NUTRIENT MANAGEMENT PLANNING (NMP) CRITERIA IS ALSO GENERALLY REQUIREDCERTAIN BIOSOLIDS PRODUCTS (CLASS A; EQ) HAVE BEEN TREATED, PROCESSED AND TESTED TO AN EXTENT THAT THEY ARE AVAILABLE FOR GENERAL USE WITHOUT ASITE-SPECIFIC PERMIT. BIOSOLIDS ARE AN EFFECTIVE SOIL AMENDMENT THAT CAN SUPPLY ORGANIC MATTER AND ESSENTIAL MACRO/MICRONUTRIENTS WHEN APPLIEDAND UTILIZED PROPERLY. APPLICATION RATES MAY VARY FROM < 5 TO 35 DRY TONS PER ACRE PER DEPENDING ON SITE-SPECIFIC SOIL CONDITIONS AND NUTRIENTMANAGEMENT/LOSS CONSIDERATIONS. CERTAIN COMPOSTED PRODUCTS ALSO CONTAIN BIOSOLIDS AND ARE AVAILABLE FOR USE AS A REVEGETATION SOIL AMENDMENT.LIME:DETERMINE LIME NEEDS BY SOIL TESTS, WHICH MAY BE PERFORMED BY THE COOPERATIVE EXTENSION SERVICE SOIL TESTING LABORATORY AT VIRGINIA POLYTECHNICINSTITUTE AND STATE UNIVERSITY (VPI&SU) OR BY A REPUTABLE COMMERCIAL LABORATORY. INFORMATION CONCERNING THE STATE SOIL TESTING LABORATORY ISAVAILABLE FROM COUNTY EXTENSION AGENTS.REFERENCE TABLE C-SSM-10-10 FOR LIMING APPLICATIONS NEEDED TO CORRECT UNDESIRABLE PH FOR VARIOUS SOIL TYPES.UNDER UNUSUAL CONDITIONS, WHERE IT IS NOT POSSIBLE TO OBTAIN A SOIL TEST, APPLY AN AGRICULTURAL GRADE OF LIMESTONE AT THE FOLLOWING RATES. COASTALPLAIN — 2 TONS/ACRE (90 LBS./1,000 FT2) PIEDMONT AND APPALACHIAN REGION — 2 TONS/ACRE (90 LBS./1,000 FT2)LIMING MATERIALS SHOULD BE LABELED AND APPROVED BY VDACS.FERTILIZER:DETERMINE FERTILIZER NEEDS BY SOIL TESTS, WHICH MAY BE PERFORMED BY THE COOPERATIVE EXTENSION SERVICE SOIL TESTING LABORATORY AT VPI&SU(HTTPS://WWW.SOILTEST.VT.EDU/) OR BY A REPUTABLE COMMERCIAL LABORATORY. INFORMATION CONCERNING THE SOIL TESTING LABORATORY IS AVAILABLE FROMCOUNTY EXTENSION AGENTS. ALL FERTILIZER MATERIALS SHOULD BE VDACS APPROVED AND LABELED.UNDER UNUSUAL CONDITIONS, WHERE IT IS NOT POSSIBLE TO OBTAIN A SOIL TEST, APPLY A FERTILIZER AT THE FOLLOWING RATES.MIXED GRASSES & LEGUMES: 1,000 LBS./ACRE (23 LBS./1,000 FT2) OF 10-20-10 (N-P2O5-K2O) OR EQUAL. THESE RATES APPLY TO ESTABLISHMENT NEEDS ONLY ANDSUBSEQUENT POST-ESTABLISHMENT FERTILIZATION WITH N WILL BE REQUIRED FOR PURE GRASS STANDS OR STANDS WHERE AT LEAST A 25% LEGUME COMPONENT DOESNOT PERSIST. FOLLOW-UP APPLICATIONS OF P2O5 MAY ALSO BE REQUIRED FOR EXPOSED FINE-TEXTURED, ACIDIC AND HIGH CLAY SUBSOIL MATERIALS. THESE SUBSOILSARE TYPICALLY RED TO REDDISH YELLOW IN COLOR. ADDITIONAL K2O IS ALSO REQUIRED FOR FREQUENTLY MOWED STANDS OR ON VERY SANDY SOILS. ALL FERTILIZERAPPLICATION SHOULD BE BASED ON SOIL TESTING BY THE VIRGINIA TECH SOIL TESTING LABORATORY OR ANOTHER DCR APPROVED LABORATORY.LEGUME STANDS ONLY: 1,000 LBS./ACRE (23 LBS./ 1,000 FT2) OF 5-20-10 IS PREFERRED 1,000 LBS./ACRE (23 LBS./ 1,000 FT2) OF 10-20-10 OR EQUALGRASS STANDS ONLY: 1,000 LBS./ACRE (23 LBS./1,000 FT2) OF 10-20-10 OR EQUAL USE OTHER FERTILIZER FORMULATIONS, INCLUDING SLOW-RELEASE SOURCES OFNITROGEN (PREFERRED FROM A WATER QUALITY STANDPOINT), PROVIDED THESE FERTILIZERS CAN SUPPLY THE SAME AMOUNTS AND PROPORTIONS OF PLANTNUTRIENTS.INCORPORATION:INCORPORATE LIME AND FERTILIZER INTO THE TOP 4 TO 6 INCHES OF THE SOIL BY DISCING OR OTHER MEANS WHENEVER POSSIBLE. FOR EROSION CONTROL, WHENAPPLYING LIME AND FERTILIZER WITH A HYDROSEEDER, APPLY TO A ROUGH, LOOSE SURFACE.SEEDING:CERTIFIED SEED: USE CERTIFIED SEED FOR ALL PERMANENT SEEDING WHENEVER POSSIBLE. CERTIFIED SEED IS INSPECTED BY THE VCIA OR THE CERTIFYING AGENCY INOTHER STATES. USE SEED THAT MEETS THE PUBLISHED STATE STANDARDS AND BEARS AN OFFICIAL “CERTIFIED SEED” LABEL (SEE SEED QUALITY CRITERIA IN ROW 2 OFTHIS TABLE).LEGUME SEED: USE LEGUME SEED INOCULATED WITH THE INOCULANT APPROPRIATE TO THE SPECIES. SCARIFY SEED OF THE LESPEDEZAS AND THE CLOVERS SPECIES TOPROMOTE UNIFORM GERMINATION.APPLICATION: APPLY SEED UNIFORMLY WITH A BROADCAST SEEDER, DRILL, CULTI-PACKER SEEDER, OR HYDROSEEDER ON A FIRM, FRIABLE SEEDBED. ENSURE THESEEDING DEPTH IS BETWEEN 0.25 TO 0.5 INCH.HYDROSEEDING: TO AVOID POOR GERMINATION RATES BECAUSE OF SEED DAMAGE DURING HYDROSEEDING, ADD 50 PERCENT MORE SEED TO THE TANK IF MACHINERYBREAKS DOWN FOR 30 MINUTES TO 2 HOURS BASED ON THE PROPORTION OF THE SLURRY REMAINING IN THE TANK. BEYOND 2 HOURS, A FULL RATE OF NEW SEED MAY BENECESSARY.OFTEN, HYDROSEEDING CONTRACTORS PREFER NOT TO APPLY LIME IN THEIR RIGS, AS IT IS ABRASIVE. IN INACCESSIBLE AREAS, APPLY LIME SEPARATELY IN PELLETIZEDOR LIQUID FORM. SURFACE ROUGHENING IS PARTICULARLY IMPORTANT WHEN HYDROSEEDING, AS A ROUGHENED SLOPE WILL PROVIDE SOME NATURAL COVERAGE OFLIME, FERTILIZER, AND SEED. APPLY INOCULANTS AT FIVE TIMES THE RECOMMENDED RATE WHEN INOCULANT IS INCLUDED IN THE HYDROSEEDER SLURRY.MULCHING:MULCH ALL PERMANENT SEEDING IMMEDIATELY UPON COMPLETION OF SEED APPLICATION IN ACCORDANCE WITH MULCHING (C-SSM-11).MAINTENANCE OF NEW SEEDINGS:IN GENERAL, A STAND OF VEGETATION CANNOT BE DETERMINED TO BE FULLY ESTABLISHED UNTIL IT HAS BEEN MAINTAINED FOR 1 FULL YEAR AFTER PLANTING.IRRIGATION:SUPPLY NEW SEEDINGS WITH ADEQUATE MOISTURE. SUPPLY WATER AS NEEDED, ESPECIALLY LATE IN THE SEASON, IN ABNORMALLY HOT OR DRY WEATHER, OR ONADVERSE SITES. CONTROL WATER APPLICATION RATES TO PREVENT EXCESSIVE RUNOFF INADEQUATE AMOUNTS OF WATER MAY BE MORE HARMFUL THAN NO WATER.RESEEDING:INSPECT SEEDED AREAS FOR FAILURE AND MAKE NECESSARY REPAIRS AND RESEEDINGS WITHIN THE SAME SEASON IF POSSIBLE.IF VEGETATIVE COVER IS INADEQUATE TO PREVENT RILL EROSION, OVER-SEED AND FERTILIZE IN ACCORDANCE WITH SOIL TEST RESULTS.IF A STAND HAS LESS THAN 40 PERCENT COVER, RE-EVALUATE CHOICE OF PLANT MATERIALS AND QUANTITIES OF LIME AND FERTILIZER. TEST THE SOIL TO DETERMINE IFACIDITY OR NUTRIENT IMBALANCES ARE RESPONSIBLE. RE-ESTABLISH THE STAND FOLLOWING SEEDBED PREPARATION AND SEEDING RECOMMENDATIONS.POST-ESTABLISHMENT FERTILIZATION:BEGIN FERTILIZATION OF INTENSIVELY MANAGED/MOWED COOL-SEASON GRASSES 90 DAYS AFTER PLANTING TO ENSURE PROPER STAND AND DENSITY. BEGINFERTILIZATION OF INTENSIVELY MANAGED/MOWED WARM-SEASON GRASSES AT 30 DAYS AFTER PLANTING.APPLY MAINTENANCE LEVELS OF FERTILIZER AS DETERMINED BY SOIL TEST. IN THE ABSENCE OF A SOIL TEST, CONDUCT FERTILIZATION AS FOLLOWS:COOL-SEASON GRASSES4 LBS. NITROGEN PER 1,000 FT2 PER YEAR1 LB. PHOSPHORUS PER 1,000 FT2 PER YEAR2 LBS. POTASH PER 1,000 FT2 PER YEARAPPLY 75 PERCENT OF THE TOTAL REQUIREMENTS BETWEEN SEPTEMBER 1 AND DECEMBER 31. APPLY THE BALANCE DURING THE REMAINDER OF THE YEAR. DO NOTAPPLY MORE THAN 1 LB. OF SOLUBLE NITROGEN PER 1,000 FT2 AT ANY ONE TIME.WARM-SEASON GRASSESAPPLY 4 TO 5 LBS. NITROGEN PER 1,000 FT2 PER YEAR BETWEEN MAY 1 AND AUGUST 15. APPLY PHOSPHORUS AND POTASH ACCORDING TO SOIL TEST.NOTE: THE USE OF SLOW-RELEASE FERTILIZER FORMULATIONS FOR MAINTENANCE OF TURF IS ENCOURAGED TO REDUCE THE NUMBER OF APPLICATIONS AND THE IMPACTON GROUNDWATER. LESS INTENSIVE POST-ESTABLISHMENT FERTILIZER APPLICATIONS MAY BE REQUIRED FOR LOW-INTENSITY UN-MOWED STANDS, PARTICULARLY WHENAT LEAST 25% LEGUMES ARE PRESENT. HOWEVER, STAND DENSITY AND VIGOR SHOULD BE EVALUATED PERIODICALLY IF LOWER FERTILIZATION RATES ARE EMPLOYED.SOIL TESTING SHOULD BE UTILIZED FOR ROUTINE P AND K PRESCRIPTIONS OVER TIME, BUT NOT FOR N RECOMMENDATIONS. MAINTENANCE OF PH > 5.5 IS ESSENTIAL FORBOTH GRASS AND LEGUME PERSISTENCE IN PERMANENT SEEDINGS.OTHER ADDITIVES:A WIDE RANGE OF OTHER SOIL AMENDMENTS INCLUDING BYPRODUCT LIMES, DIGESTATES, BIOCHAR, AND VARIOUS PROCESSED ANIMAL MANURE PRODUCTS AREAVAILABLE FOR UTILIZATION IN PERMANENT SEEDING APPLICATIONS. HOWEVER, USERS SHOULD ENSURE THAT ANY SOIL BULK SOIL AMENDMENT HAS BEEN APPROVEDFOR SUCH USE BY VDACS, VDEQ OR DCR AND THAT APPLICATION COMPLIES WITH APPROPRIATE LABELING OR NMP LIMITATIONS. C-809EROSION ANDSEDIMENTCONTROLNOTES ANDDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA220135.00-0A----->LAYOUT: C-809 ERODYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-CNDSPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026DETAILS BY OTHERS DISCLAIMERNOTES REGARDING DETAILS BY OTHERS:1.DETAILS PREPARED BY OTHERS ARE IDENTIFIED AS SUCH BY WAY OF A TITLE BLOCK,REFERENCE, LOGO, OR OTHER NOTATION.2.WHERE AN ORIGINAL DETAIL BY OTHERS HAS BEEN MODIFIED, THE MODIFICATIONS AREIDENTIFIED BY REVISION CLOUDS.3.REFER TO OUTSIDE SOURCE NOTES ON THE GENERAL NOTES AND LEGEND SHEET.4.WHEN THE SOURCE OF THE DETAIL IS A REVIEWING/REGULATORY AGENCY,FABRICATION AND INSTALLATION SHALL BE IN ACCORDANCE WITH APPLICABLEREQUIREMENTS AND SPECIFICATIONS. WHEN APPROPRIATE, SHOP DRAWINGS SHALLBE FORWARDED TO THE REVIEWING/REGULATORY AGENCY PRIOR TO FABRICATION. LODLODLODLODLODLODLODLODLODLODLOD LODLOD LOD LOD LOD LODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLOD LOD LOD LOD LODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODEE E E E E E E E E FRONT ROYAL PIKE - U.S. ROUTE 522 LOT 1GARBER ESTATE SUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)ZONING: B2N46°13'28"E 367.43'COSTELLO DRIVE 34-1367ELOD LODLOD LOD LOD LOD LODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODWESNORTH ZONEVCS NAD83/2011LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLODLODLODLODLODLODLODLODLODLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWSSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSFSSFSSFSSFSSFCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSF 0SCALE:1" = 50'505012.525C-901PREDEVELOPMENTDRAINAGEAREA MAP May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-HYDR-NJA220135.00-0A----->LAYOUT: C-901 PRE DEVYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-HYDRPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026 MIXED OPEN AREA (HSG D) = 4.50 ACPRE DEVELOPMENT DRAINAGE MAP LEGEND IMPERVIOUS AREA (HSG D) = 7.14 AC MANAGED TURF AREA (HSG D) = 1.21 ACTOTAL LIMITS OF DISTURBANCE = 12.85 AC LODLODLODLODLODLODLODLODLODLODLOD LODLOD LOD LOD LOD LODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLOD LOD LOD LOD LODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODDSSW W W W W W W W W WWS S DDDDDDDDSLS S S S S SC/OC/OC/ODDT T T T T T T T T T T T TT T TEE E E E E E E E E DDDDDDFRONT ROYAL PIKE - U.S. ROUTE 522 LOT 1GARBER ESTATE SUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)ZONING: B2N46°13'28"E 367.43'COSTELLO DRIVE 34-1367ELOD LODLOD LOD LOD LOD LODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODWESNORTH ZONEVCS NAD83/2011LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLODLODLODLODLODLODLODLODLODLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWSSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSFSSFSSFSSFSSFCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSF 718719720721722723 724 723724721720721716717718719720721717718719720721722723720721722 71671671571571671871771871571671771871471471571 4 714716 7 1 7 7107117127137147157 1 6716 7 0 8 7 0 9 7 107117127 1 3714715716 7177177 1 6 717714 715 7 1 5 71 5 7 1 6 71771871871 8 71 7 717 718 71 8 7 1 5 716 717 7177 1 7 7 1 8 718719720721716 717 704 705 706 707 708 709 710 711 712 713 714 710 711 712 705706 707 7057067077087097107117 1 2 71 3 7 1 5716717717 7 1 8 7190SCALE:1" = 50'505012.525C-902POSTDEVELOPMENTDRAINAGEAREA MAP May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-HYDR-NJA220135.00-0A----->LAYOUT: C-902 POST DEVYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-HYDRPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026MANAGED TURF AREA (HSG D) = 2.36 ACIMPERVIOUS AREA (HSG D) = 10.49 ACPOST DEVELOPMENT DRAINAGE MAP LEGENDTOTAL LIMITS OF DISTURBANCE = 12.85 ACOUTFALL TOCONVEYANCESYSTEM IN FRONTROYAL PIKE LODLODLODLODLODLODLODLODLODLODLOD LODLOD LOD LOD LOD LODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLOD LOD LOD LOD LODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPROP 5' SIDEWALKPROP 5' SIDEWALKPROP 5' SIDEW A L K PROP 5' SIDEWALK DSSW W W W W W W W W WWS S DDDDDDDDSLS S S S S SC/OC/OC/ODDT T T T T T T T T T T T TT T TEE E E E E E E E E DDDDDDFRONT ROYAL PIKE - U.S. ROUTE 522 LOT 1GARBER ESTATE SUBDIVISIOND.B. 838 PG. 1360LANDS OFTHE PRICE COMPANYD.B. 829 PG. 487TM: 64-8-1AREA: 13.002 AC. (R&M)OR 566,356 S.F. (M)ZONING: B2N46°13'28"E 367.43'COSTELLO DRIVE 34-1367ELOD LODLOD LOD LOD LOD LODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODWESNORTH ZONEVCS NAD83/2011LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLODLODLODLODLODLODLODLODLODLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWSSF SSF SSF SSF SSF SSF SSF SSF SSF SSF SSFSSFSSFSSFSSFCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSFSSF 718719720721722723 724 723724721720721716717718719720721717718719720721722723720721722 71671671571571671871771871571671771871471471571 4 714716 7 1 7 7107117127137147157 1 6716 7 0 8 7 0 9 7 107117127 1 3714715716 7177177 1 6 717714 715 7 1 5 71 5 7 1 6 71771871871 8 71 7 717 718 71 8 7 1 5 716 717 7177 1 7 7 1 8 718719720721716 717 704 705 706 707 708 709 710 711 712 713 714 710 711 712 705706 707 7057067077087097107117 1 2 71 3 7 1 5716717717 7 1 8 7190SCALE:1" = 50'505012.525C-903BMP MAP May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-HYDR-NJA220135.00-0A----->LAYOUT: C-903 BMP MAPYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-HYDRPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026AREA TO UNDG SWM SYSTEM #1IMPERVIOUS AREA: MANAGED TURF AREA:ON-SITE: 5.74 ACON-SITE: 0.74 ACPASS-THROUGH: 2.89 ACPASS-THROUGH: 0.91 ACTOTAL AREA: 10.28 ACAREA TO UNDG SWM SYSTEM #2IMPERVIOUS AREA: MANAGED TURF AREA:ON-SITE: 3.91 ACON-SITE: 0.43 ACPASS-THROUGH: 1.52 ACPASS-THROUGH: 0.05 ACTOTAL AREA: 5.91 ACAREA TO UNDG SWM SYSTEM #3IMPERVIOUS AREA: MANAGED TURF AREA:ON-SITE: 0.42 ACON-SITE: 0.66 ACPASS-THROUGH: 9.69 ACPASS-THROUGH: 1.52 ACTOTAL AREA: 12.33 ACUNDETAINED AREA:IMPERVIOUS AREA: MANAGED TURF AREA:ON-SITE: 0.24 ACON-SITE: 0.56 ACTOTAL AREA: 0.80 ACBMP DRAINAGE MAP LEGEND C-904VRRMSPREADSHEET May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMP-NJA220135.00-0A----->LAYOUT: C-904 VRRM SPREADSHEETYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMPPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026WATER QUALITYNARRATIVEPER THE VRRM PROVIDED THE UNDERGROUND SYSTEMS WITHFILTERING DEVICES EXCEED THE TOTAL PHOSPHORUSREDUCTION BY 0.8 LB/YEAR. PASS-THROUGH AREA ON-SITESHOWN PER BMP MAP ON SHEET C-903.UNDERGROUND SYSTEM #1UNDERGROUND SYSTEM #2 C-905STORMWATERMANAGEMENTPLAN May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMP-NJA220135.00-0A----->LAYOUT: C-905 SWMPYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMPPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026SWM MAINTENANCEUNDERGROUND DETENTION SYSTEMS AND UNDERGROUND VAULTS ARE TO BE PRIVATELY MAINTAINED BY THE PROPERTY OWNER TO THEEXTENT THAT THEY ARE NOT MAINTAINED BY FREDERICK COUNTY PER SECTION § 143-165 OF THE FREDERICK COUNTY CODE. MAINTENANCEAGREEMENT TO BE PREPARED AT TIME OF PLAN APPROVAL.STORMWATER MANAGEMENT & BMP NARRATIVEEXISTING CONDITIONSTHE EXISTING 17.29 ACRE SITE CONSISTS OF A 13 ACRE COSTCO WHOLESALE DEVELOPMENT AND A 4.29 ACRE UNDEVELOPED PARCEL. THE COSTCO WHOLESALEDEVELOPMENT CONSISTS PRIMARILY OF AN APPROXIMATELY 136,000 SF BUILDING, FUELING CANOPY AND ATTENDENT BUILDING, ASSOCIATED PARKING AND ABOVEGROUND STORMWATER MANAGEMENT. THE UNDEVELOPED PARCEL CONSISTS OF MIXED OPEN SPACE AND A RETENTION BASIN ALONG COSTELLO DRIVE SERVINGTHE DEVELOPMENTS SOUTH OF COSTELLO AND COSTELLO DRIVE.BOTH DEVELOPMENTS OUTFALL TO THE SOUTHEAST TO A CATCH BASIN LOCATED AT THE SOUTHEAST CORNER OF THE UNDEVELOPED PARCEL. THIS CATCH BASINWILL BE THE POINT OF INTEREST FOR STORMWATER QUALITY AND QUANTITY DESIGN. THE OFFSITE CONVEYANCE SYSTEM OUTLETS FROM A HEADWALLAPPROXIMATELY 370' ON THE SOUTH OF COSTELLO DRIVE TO AN UNMANANAGED GRASS SWALE. THE ULITMATE OUTFALL IS LOCATED AT SULFUR SPRING RUNLOCATED APPROXIMATELY 1500' FROM THE OUTLET HEADWALL.PROPOSED IMPROVEMENTSTHE PURPOSE OF THIS PROJECT IS TO REVELOPED THE COSTCO PARCEL AND INCORPORATE THE UNDEVELOPED PARCEL. IMPROVEMENTS ARE LISTED:-A 20,709 SF BUIDLING ADDITION AND LOADING DOCK IS PROPOSED ON THE EAST SIDE OF THE EXISTING COSTCO BUILDING.-THE EXISTING GAS STATION WILL BE RELOCATED FROM ALONG FRONT ROYAL PIKE TO THE NORTHEAST CORNER OF THE SITE.-THE EXISTING ON-SITE RETENTION BASINS WILL BE RETROFIT TO 3 UNDERGROUND STORMWATER MANAGEMENT STRUCTURES-ASSOCIATED PARKING AREAS WILL BE CONSTRUCTED-PROPOSED STORMWATER CONVEYANCE WILL BE RECONSTRUCTED ON THE NORTH SIDE OF COSTELLO DRIVE.-ALL RELATED SITE INFRASTRUCTURE.-THE TOTAL DISTURBED AREA FOR THE CONSTRUCTION ACTIVITY IS ANTICIPATED TO BE 12.85 ACRES.CHANNEL PROTECTION: THIS SITE DISCHARGE POINT OUTFALLS TO AN EXISTING CATCH BASIN LOCATED AT THE SOUTHEAST CORNER OF THE SUBJECT PARCEL, AMANMADE STORMWATER CONVEYANCE FROM THE SITE DISCHARGE TO THE LIMITS OF ANALYSIS. THE LIMITS OF ANALYSIS IS BASED ON COMPLIANCE WITH ENERGYBALANCE ENDING THE REQUIRED ANALYSIS AT THE SITE DISCHARGE POINT. SEE THE STORMWATER OUTFALL TABLE ON THIS SHEET.FLOOD PROTECTION: THIS SITE DISCHARGE POINT OUTFALLS TO AN EXISTING STORM SEWER (EX-5) ON THE SOUTHEAST CORNER OF THE SUBJECT PARCEL, NORTHOF COSTELLO DRIVE THAT CURRENTLY EXPERIENCES LOCALIZED FLOODING DURING THE 10-YEAR 24 HOUR STORM EVENT. LOCALIZED FLOODING IS DEFINED ASSMALLER SCALE FLOODING THAT MAY OCCUR OUTSIDE OF A STORMWATER CONVEYANCE SYSTEM AND MAY INCLUDE HIGH WATER, PONDING, OR STANDING WATERFROM STORMWATER RUNOFF, WHICH IS LIKELY TO CAUSE PROPERTY DAMAGE OR UNSAFE CONDITIONS. ANALYSIS OF THE EXISTING STORM SEWER SYSTEM ANDDISCHARGE OF THE EXISTING ON SITE PONDS, IT HAS BEEN DETERMINED THAT THE SYSTEM DOES NOT CONTAIN THE 10-YR HYDRAULIC GRADE LINE. THE OUTFALLOF EX POND #2, UTILIZES A SPILLWAY TO CONVEY THE 10-YR STORM, CONTRIBUTING TO THE LOCALIZED FLOODING OF THE OUTFALL STRUCTURE AND DOWNSTREAMCONVEYANCE SYSTEM. ANALYSIS OF THE DOWNSTREAM CONVEYANCE SYSTEM IS OUTLINED ON THIS SHEET WITH ANALYSIS OF THE EXISTING SYSTEM DETAILED ONTHE STORMWATER FYI SHEETS C-920 AND C-921.STORMWATER MANAGEMENT PLAN NOTES:1.SEE SHEETS C-906 - C-909 FOR THE SUPPORTING HYDROGRAPH CALCULATIONS FOR THE ROUTING DIAGRAMS AND FINAL OUTFALLS ON THIS SHEET.2.SEE SHEETS C-910 TO C-919 FOR THE BMP DETAILS ASSOCIATED WITH THE OUTFALL FOR THE PROPOSED SITE.EXISTING ROUTINGDIAGRAMPROPOSED ROUTINGDIAGRAMFINAL OUTFALL PRE DEVELOPMENTSUMMARIES1-YR STORM EVENT2-YR STORM EVENT10-YR STORMEVENTFINAL OUTFALL POST DEVELOPMENTSUMMARIES1-YR STORM EVENT2-YR STORM EVENT10-YR STORMEVENTEXISTING OUTFALL 10-YR ANALYSIS FOR LOCALIZEDFLOODING C-906HYDROCADROUTINGS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMP-NJA220135.00-0A----->LAYOUT: C-906 HYDROCAD ROUTINGSYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMPPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/20261-YR STORM HYDROGRAPHSPRE-EXISTING CONDITIONSHYDROGRAPHS2-YR STORMHYDROGRAPHS C-907HYDROCADROUTINGS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMP-NJA220135.00-0A----->LAYOUT: C-907 HYDROCAD ROUTINGSYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMPPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026PRE-EXISTING CONDITIONSHYDROGRAPHS10-YR STORM HYDROGRAPHS C-908HYDROCADROUTINGS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMP-NJA220135.00-0A----->LAYOUT: C-908 HYDROCAD ROUTINGSYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMPPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/20261-YR STORM HYDROGRAPHSPOST-DEVELOPED CONDITIONSHYDROGRAPHS2-YR STORM HYDROGRAPHS C-909HYDROCADROUTINGS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMP-NJA220135.00-0A----->LAYOUT: C-909 HYDROCAD ROUTINGSYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMPPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/202610-YR STORM HYDROGRAPHSPOST-DEVELOPED CONDITIONSHYDROGRAPHS C-910STORMWATERMANAGEMENTDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMD-NJA220135.00-0A----->LAYOUT: C-910 SWMDYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMDPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026UNDERGROUND SYSTEM #1 POST-DEVELOPMENTSUMMARIES1-YR STORM EVENT10-YR STORMEVENT2-YR STORM EVENT C-911STORMWATERMANAGEMENTDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMD-NJA220135.00-0A----->LAYOUT: C-911 SWMDYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMDPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026SCALE: NTSPLAN VIEWSCALE: NTSSECTION B-BSCALE: NTSSECTION C-COUTLET STRUCTURE DETAIL (STM B-150)(STRUCTURAL DESIGN BY OTHERS)SCALE: NTS60"INFLOWFROMUNDERGROUNDDETENTIONRIM: ± 715.60(REFER TOGRADING PLAN)6"2 X 12" ORIFICE(ELEV = 704.00)WEIR WALL MADE OF STEELOR APPROVED EQUIVALENT6"36" RCPINV 704.00OUTLET PIPEWEIR WALL MADE OFSTEEL OR APPROVEDEQUIVALENTBBCC6' BROAD-CRESTED RECTANGULARWEIR (ELEV = 708.50)24" HDPE FROMUNDERGROUNDDETENTION2 X 12" ORIFICEINV: 704.0036" RCPOUTLETPIPE2 X 12"PRIMARYORIFICE4' BROAD-CRESTEDRECTANGULAR WEIR(ELEV = 708.50)48"STAGE-STORAGESTAGE-DISCHARGEUNDERGROUND SYSTEM #1 DESIGN DETAILS C-912STORMWATERMANAGEMENTDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMD-NJA220135.00-0A----->LAYOUT: C-912 SWMDYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMDPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026UNDERGROUND SYSTEM #1 DESIGN DETAILS C-913STORMWATERMANAGEMENTDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMD-NJA220135.00-0A----->LAYOUT: C-913 SWMDYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMDPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/20261-YR STORM EVENT10-YR STORMEVENT2-YR STORM EVENTUNDERGROUND SYSTEM #2 POST-DEVELOPMENTSUMMARIES C-914STORMWATERMANAGEMENTDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMD-NJA220135.00-0A----->LAYOUT: C-914 SWMDYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMDPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026SCALE: NTSPLAN VIEWSCALE: NTSSECTION B-BSCALE: NTSSECTION C-COUTLET STRUCTURE DETAIL (STM B-131)(STRUCTURAL DESIGN BY OTHERS)SCALE: NTS48"INFLOWFROMUNDERGROUNDDETENTIONRIM: ± 715.60(REFER TOGRADING PLAN)6"12" ORIFICE(ELEV = 703.16)WEIR WALL MADE OF STEELOR APPROVED EQUIVALENT6"24" RCPINV 703.16OUTLET PIPEWEIR WALL MADE OFSTEEL OR APPROVEDEQUIVALENTBBCC3' BROAD-CRESTED RECTANGULARWEIR (ELEV = 707.00)24" HDPE FROMUNDERGROUNDDETENTION7" ORIFICE INV:704.7524" RCPOUTLETPIPE12" PRIMARYORIFACE36"3' BROAD-CRESTEDRECTANGULAR WEIR(ELEV = 707.00)STAGE-STORAGESTAGE-DISCHARGEUNDERGROUND SYSTEM #2 DESIGN DETAILS C-915STORMWATERMANAGEMENTDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMD-NJA220135.00-0A----->LAYOUT: C-915 SWMDYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMDPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026UNDERGROUND SYSTEM #2 DESIGN DETAILS C-916STORMWATERMANAGEMENTDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMD-NJA220135.00-0A----->LAYOUT: C-916 SWMDYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMDPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/20261-YR STORM EVENT10-YR STORMEVENT2-YR STORM EVENTUNDERGROUND SYSTEM #3 POST-DEVELOPMENTSUMMARIES C-917STORMWATERMANAGEMENTDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMD-NJA220135.00-0A----->LAYOUT: C-917 SWMDYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMDPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026SCALE: NTSPLAN VIEWSCALE: NTSSECTION B-BSCALE: NTSSECTION C-COUTLET STRUCTURE DETAIL (STM B-111)(STRUCTURAL DESIGN BY OTHERS)SCALE: NTS60"INFLOWFROMUNDERGROUNDDETENTIONRIM: ± 715.60(REFER TOGRADING PLAN)6"16" ORIFICE(ELEV = 699.00)WEIR WALL MADE OF STEELOR APPROVED EQUIVALENT6"36" RCPINV 699.00OUTLET PIPEWEIR WALL MADE OFSTEEL OR APPROVEDEQUIVALENTBBCC4' BROAD-CRESTED RECTANGULARWEIR (ELEV = 702.35)24" HDPE FROMUNDERGROUNDDETENTION16" ORIFICE INV:699.0036" RCPOUTLETPIPE16" PRIMARYORIFACE4' BROAD-CRESTEDRECTANGULAR WEIR(ELEV = 702.35)48"STAGE-STORAGESTAGE-DISCHARGEUNDERGROUND SYSTEM #3 DESIGN DETAILS C-918STORMWATERMANAGEMENTDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMD-NJA220135.00-0A----->LAYOUT: C-918 SWMDYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMDPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026UNDERGROUND SYSTEM #3 DESIGN DETAILS C-919STORMWATERMANAGEMENTDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMD-NJA220135.00-0A----->LAYOUT: C-919 SWMDYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMDPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026UNDERGROUND SYSTEM #3 DESIGN DETAILS C-920STORMWATERFYI May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMD-NJA220135.00-0A----->LAYOUT: C-920 STORMWATER FYIYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMDPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026FOR STORMWATER INFORMATIONAL PURPOSES ONLY C-921STORMWATERFYI May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-SWMD-NJA220135.00-0A----->LAYOUT: C-921 STORMWATER FYIYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-SWMDPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026FOR STORMWATER INFORMATIONAL PURPOSES ONLY C-1001CONSTRUCTIONDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA220135.00-0A----->LAYOUT: C-1001 DETLYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-CNDSPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026NOTES:1.LOCATION - THE SIGN(S) MAY BE LOCATED WITHIN THE SIDEWALK (IN A BOLLARD OR OTHER PROTECTIVESTRUCTURE), MOUNTED ON A SIGN POST BEHIND THE SIDEWALK OR OTHER LOCATION BEYOND THE POTENTIAL FORVEHICLE INTERACTION, OR MOUNTED ON A BUILDING OR OTHER STRUCTURE. REFER TO PLANS FOR LOCATIONS.2.SIGN MOUNTING HEIGHT - A MINIMUM 60", AS MEASURED FROM FINISHED GRADE TO THE BOTTOM OF THE SIGN, SHALLBE PROVIDED. IN SITUATIONS WHERE VAN SPACES ARE PROVIDED, THE MEASUREMENT SHALL BE TO THE BOTTOMOF THE 'VAN ACCESSIBLE' (R7-8P) SIGN. WHEN NO VAN SPACES ARE PROVIDED, THE MEASUREMENT SHALL BE TOTHE BOTTOM OF THE 'RESERVED PARKING' (R7-8) SIGN. FOR UNIFORMITY, WHEN THERE IS A COMBINATION OF VANSPACES AND NON-VAN SPACES IN ON PARKING ROW, THE TOPS OF THE 'RESERVED PARKING' (R7-8) SIGNS SHALL BECONSISTENT.3.SIGN SPECIFICATIONS - UNLESS OTHERWISE REQUIRED BY STATE OR LOCAL REQUIREMENTS, THE R7-8 AND R7-8PSIGNS SHALL BE PER MUTCD SPECIFICATIONS. THE PENALTY SIGN SHALL BE PER STATE OR LOCAL REQUIREMENTSAND SHALL BE 12"x18".4.IF THE SIGN IS LOCATED IN A PEDESTRIAN WALKING PATH, THE MINIMUM MOUNTING HEIGHT TO THE BOTTOM OF THELOWEST PROVIDED SIGN SHALL BE 84" PER MUTCD STANDARDSSIGN POST (SEE DETAIL)EMBEDDED IN BOLLARD IFSPECIFIED ON DRAWINGS(SEE DETAIL)FINISHED GRADEPROP FLUSH CURBLINEOR EDGE OF PAVEMENT(SEE DETAIL)PAVEMENT SECTION (SEE DETAIL)RESERVED PARKING SIGNNOT TO SCALE(BE-S060101 - 01/2025)IF ADA WALKING PATH BEHINDTHE SIGN, ENSURE MINIMUMCLEARANCEOF 36" IS PROVIDED TOEDGE OF BOLLARD OR SIGN ORAS OTHEWISE REQUIRED BYLOCAL AHJ FOR ADA PATHWAYEND OF PARKING STALL 1.5' TO CENTEROF BOLLARD (UNLESSOTHERWISE SPECIFIEDON THE DRAWINGS)RESERVEDPARKINGVANACCESSIBLER7-8 (12"x18")R7-8P (6"x12")(SEE PLANS FORLOCATIONS WHEREPROVIDED)OPTIONALPENALTY SIGN60" MIN ABOVE GRADEWHEN VAN SPACESARE NOT PROVIDED(SEE NOTE BELOW)60" MIN ABOVE GRADE ADA PARKINGSTALL MARKINGNOT TO SCALE(BE-S050104 - 05/2024)CAR OR VANSPACE5' MINAISLEVAN SPACESEE SITE PLAN FOR DIMENSION CAR OR VANSPACEAISLECURBFLUSH CURB (REFER TODETAIL) TO BE PROVIDEDAT EACH ACCESS AISLE.(REFER TO SITE PLANFOR LOCATION)PROP ACCESSIBLE PARKING SIGN WITH"VAN" IDENTIFICATION (REFER TO DETAIL)TO BE PROVIDED AT EACH VAN SPACE.(REFER TO SITE PLAN FOR LOCATION)NOTE:1.REFER TO "ACCESSIBILITY NOTES" PROVIDED HEREIN FORADDITIONAL REQUIREMENTS AND SPECIFICATIONS.2.THE LAYOUT AND NUMBER OF PARKING SPACES VARIES.REFER TO PLAN FOR LOCATION AND CONFIGURATION.3.STALL DIMENSIONS ARE MEASURED TO THE CENTERLINE OFTHE PAINTED STRIPE.4.ACCESS AISLES CAN NOT OVERLAP VEHICULAR WAYS.5.AN ACCESS AISLE AT LEAST 5' WIDE AND AT LEAST AS LONGAS THE PARKING SPACE IS REQUIRED ON EITHER SIDE OFTHE PARKING SPACE AND MUST BE MARKED TODISCOURAGE PARKING IN IT. TWO SPACES CAN SHARE ONEAISLE.PROP ACCESSIBLEPARKING SIGN (REFER TODETAIL) TO BE PROVIDEDAT EACH NON-VAN SPACEREFER TO PLAN. EITHER 8' WIDEVAN SPACE WITH 8' AISLEOR 11' WIDE VAN SPACEWITH 5' WIDE AISLE8' MIN(TYP)PROP INTERNATIONAL SYMBOL OF ACCESSIBILITY(ISA) (TYP) SHALL BE WHITE WITH A BLUEBACKGROUND WHICH EXTENDS A MINIMUM OF 3"BEYOND THE SYMBOL. VARIES SEE PLAN (12" MIN.)6"1"6"2"PAVEMENT DIMENSION(S) ON PLAN VIEW REFERTO FACE OF CURBNOTES:1. CONCRETE FOR CURBING SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 P.S.I. @ 28 DAYS.2. CONSTRUCTION STAKING FOR CURB INSTALLATION SHALL BE REFERENCED (CUT OR FILL) TO THE TOP OF CURB.3. AT CONTRACTOR'S OPTION, THE GUTTER THICKNESS MAY BE INCREASED AT THE EDGE OF PAVEMENT TO MAKE BOTTOM OFGUTTER CONTIGUOUS WITH BOTTOM OF ASPHALT PAVEMENT.4. CONTRACTION JOINTS SHALL BE PLACED @ 10'-0" O.C. TOOLED 1/4" (±1/16") WIDE, 1" DEEP. EXPANSION JOINTS SHALL BEPLACED @ 40'-0" INTERVALS, MAXIMUM, AND ALL P.C.'S.5. GUTTER PAN SLOPE TO BE ADJUSTED WITHIN ACCESSIBLE PARKING SPACES TO MATCH SLOPE BETWEEN SPOT ELEVATIONS.6. GUTTER TYPE TO MATCH PAVEMENT SLOPE DIRECTION. CONTRACTOR TO FIELD ADJUST AS NECESSARY.VARIES SEE PLAN (12" MIN.)6"2" 6"1"SPILL CURB & GUTTERCOLLECTOR CURB & GUTTER6"PAVEMENT DIMENSION(S) ON PLAN VIEWREFER TO FACE OF CURB4"1-1/2"R1-1/2"RCONCRETE CURB AND GUTTER 6" REVEALNOT TO SCALE(VA-S020202 - 03/2024)1" TEST PIT (TO BE HAND DUG)FINISHED GRADE1.5' MIN. CLEARANCEUTILITY CONFLICT1. CONTRACTOR TO COORDINATE WATERLINE ADJUSTMENT WITH APPROPRIATE INSPECTOR, BASEDUPON LOCAL JURISDICTIONAL REQUIREMENTS AND FIELD CONDITIONS.2. CONTRACTOR TO HAND DIG TEST PIT AT ANTICIPATED CROSSING LOCATION TO DETERMINE EXISTINGWATERLINE DEPTH, TOTAL WATERLINE DEFLECTION REQUIRED, AND BEST METHOD FOR WATERLINEADJUSTMENT.3. VERTICAL BENDS (INSTALLED PER LOCAL STANDARDS) AS REQUIRED.4. PIPE DEFLECTION AT JOINTS (PER LOCAL STANDARDS)WATERLINEADJUSTMENTUSING FITTINGS(VERTICAL BENDS)(SEE NOTE 3)WATERLINEADJUSTMENT USINGDEFLECTION AT PIPEJOINTS (SEE NOTE 4)EX. MAINSEE NOTE 4ADJUSTMENT TOEXTEND BEYOND LIMITSOF CONFLICTS (3' MIN.,EACH SIDE, CHECKLOCAL STANDARDS).NOTES:WATERLINEADJUSTMENTNOT TO SCALE(BE-U039901 - 01/2025) VARIES12"12"24" MIN8' MIN6"TYPSINGLE 4" WIDE SOLIDYELLOW LINE(SEE SITE PLAN)10' MIN (SEE PLAN) 4.0'EDGE OF ROADWAY OR SIDEWALKSOLID WHITE PAINT(SEE NOTE BELOW)LOCATION OF STOP SIGN SHALLBE IN LINE WITH STOP BARSTOP BARNOT TO SCALE(MS-S050301 - 07/2024) TACK COAT(APPLIED AT A RATE OF0.2 GALLONS/S.Y.)PAVEMENT SURFACE(SEE PAVEMENT DETAIL)CONCRETE PAVEMENT SECTIONCONCRETE-TO-ASPHALTNOT TO SCALE(BE-S010201 - 01/2025) 3' TAPER_' CURBBREAK3' TAPERGUTTER PAN (IF SPECIFIED) 3' RIP-RAP PAD3' TAPER_' CURBBREAK3' TAPERELEVATIONPLANPAVED SURFACE/ CONC. PADCURB, SEE SITE PLAN FOR TYPE1" RADIUSCURB BREAKNOT TO SCALE(BE-S029901 - 01/2025) SEE CURB DETAIL12"SEE PLANVARIES. SEE PLAN.NOTES:1.REFER TO THE "ACCESSIBILITYNOTES" WITHIN THE PLAN SET.18" VARIES. SEE CURB DETAIL PAVEMENTSLOPE VARIES(SEE PLAN)SECTION A-ATOPOFCURBVARIES. SEE PLANFOR LOCATIONS.24" TYP., 12" MIN.FLAREAACURB FLUSH WITHROADWAY SURFACESLOPE TO MATCHRAMP ORLANDING/TURNINGSPACE SLOPEADA FLUSH CURBNOT TO SCALE(BE-S030501 - 08/2023)18" 5" CONCRETE ( 4,000 PSI)6" COMPACTED STONE BASECOMPACTED SUBGRADE(PER GEOTECHNICAL REPORT)6x6 WWM (10 GA.)1. SECTION SHOWN IS BASED ON AN ANTICIPATED CBR OF 2.4 PER GEOTECHNICALREPORT PREPARED BY TERRACON, ENTITLED PROPOSED COSTCO FUELAND BUILDING EXPANSION - WINCHESTER, DATED MAY, 16, 2023 (PROJECT#JD235031). FINAL DESIGN TO BE PROVIDED ONCE FINAL CBR'S ARE AVAILABLEON COMPACTED SUB-BASE.NOTE:STANDARD DUTY CONCRETEPAVEMENTNOT TO SCALE(MS-S010201 - 06/2023) NOTE:1.5" ASPHALT SURFACE COURSE(SUPERPAVE SP-9.5/BINDER GRADE PG 64-22)4.0" ASPHALT BINDER COURSE(SUPERPAVE SP-12.5/BINDER GRADE PG 64-22)12" COMPACTED STONE BASECOMPACTED SUBGRADE(PER GEOTECHNICAL REPORT)HEAVY DUTY ASPHALTPAVEMENTNOT TO SCALE(MS-S010102 - 06/2023)1. SECTION SHOWN IS BASED ON AN ANTICIPATED CBR OF 2.4 PER GEOTECHNICALREPORT PREPARED BY TERRACON, ENTITLED PROPOSED COSTCO FUELAND BUILDING EXPANSION - WINCHESTER, DATED MAY, 16, 2023 (PROJECT#JD235031). FINAL DESIGN TO BE PROVIDED ONCE FINAL CBR'S ARE AVAILABLEON COMPACTED SUB-BASE. NOTE:1.5" ASPHALT SURFACE COURSE(SUPERPAVE SP-9.5/BINDER GRADE PG 64-22)2" ASPHALT BINDER COURSE(SUPERPAVE SP-12.5/BINDER GRADE PG 64-22)6" COMPACTED STONE BASECOMPACTED SUBGRADE(PER GEOTECHNICAL REPORT)STANDARD DUTY ASPHALTPAVEMENTNOT TO SCALE(MS-S010101 - 06/2023)1. SECTION SHOWN IS BASED ON AN ANTICIPATED CBR OF 2.4 PER GEOTECHNICALREPORT PREPARED BY TERRACON, ENTITLED PROPOSED COSTCO FUELAND BUILDING EXPANSION - WINCHESTER, DATED MAY, 16, 2023 (PROJECT#JD235031). FINAL DESIGN TO BE PROVIDED ONCE FINAL CBR'S ARE AVAILABLEON COMPACTED SUB-BASE. ADA CURB RAMP -PERPENDICULARNOT TO SCALE(BE-S030505 - 11/2023)WALKABLE AREAIN ALTERATIONS WHERELESS THAN 3' IS PROVIDED,SIDE FLARES MUST BEPROVIDED WITH THESLOPES SPECIFIED BELOW.SIDE FLARE (TYP) 1:10 MAX SLOPEWHEN REQUIRED LANDING ISPROVIDED AT THE TOP OF THERAMP. 1:12 MAX WHEN THELANDING IS NOT PROVIDED.NOTES:1.REFER TO "ACCESSIBILITY NOTES" PROVIDED HEREIN FOR ADDITIONAL REQUIREMENTS ANDSPECIFICATIONS.2.DETECTABLE WARNING SURFACES (DWS) ARE DEPICTED IN ONE OF MULTIPLE CONFIGURATIONS.THE DWS SHALL BE PLACED IN ACCORDANCE WITH APPLICABLE REQUIREMENTS.3.THE CONFIGURATION OF THE RAMPS, LANDINGS, DWS, AND CROSSWALKS SHOWN IN THE DETAILARE MEANT TO DEPICT THE VARIOUS REQUIREMENTS ASSOCIATED WITH CURB RAMPS ANDRELATED ELEMENTS. REFER TO THE PLANS HEREIN FOR SPECIFIC CONFIGURATIONS.4.THE RAMP IS TO BE COMPLETELY CONTAINED WITHIN THE LIMITS OF ANY CROSSWALK LINES.5.CURB RAMPS REQUIRE LANDINGS WHERE PEDESTRIANS PERFORM TURNING MANEUVERS.48" MIN/ 60" MIN IF DEPTH ISLIMITED BY EDGE OFSIDEWALK OR BUILDINGAT LEAST ASWIDE AS RAMPFLUSH CURB (SEE DETAIL)DETECTABLE WARNING SURFACE(TYP)(SEE DETAIL) ARE TO BE PROVIDEDALONG THE ENTIRE WIDTH OF THELANDING. (REFER TO THE PLANS FORLOCATIONS WHERE DETECTABLEWARNING SURFACES ARE PROVIDED).RAMPNON-WALKABLE AREAPAVED FLARE (GRADEDFLARE IS OPTIONAL)24" MIN (TYP)12" (MIN)CROSSWALK (TYP)(SEE DETAIL) 4'-0"3'-0" 1'-0"1'-6"MIN.NOTE:1.SEE SITE PLAN FOR LOCATION(S).CONCRETE FILL TO BE ROUNDED FORPROPER RUN OFF4" DIAMETER STEEL PIPE FILLED W/CONCRETE PAINTED TRAFFICYELLOW AND EMBEDDED INCONCRETE BASETOP OF ASPHALT ORCONCRETE SLAB3000 P.S.I. CONCRETEPIPE BOLLARDNOT TO SCALE(BE-S070103 - 01/2025) CONSTRUCTION DETAILS NOTES:1.DETAILS SHOWN ON THIS SHEET ARE NOT APPLICABLE TO FREDERICK WATER. C-1002CONSTRUCTIONDETAILS May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA220135.00-0A----->LAYOUT: C-1002 DETLYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-CNDSPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026DETAILS BY OTHERS DISCLAIMERNOTES REGARDING DETAILS BY OTHERS:1.DETAILS PREPARED BY OTHERS ARE IDENTIFIED AS SUCH BY WAY OF A TITLE BLOCK,REFERENCE, LOGO, OR OTHER NOTATION.2.WHERE AN ORIGINAL DETAIL BY OTHERS HAS BEEN MODIFIED, THE MODIFICATIONS AREIDENTIFIED BY REVISION CLOUDS.3.REFER TO OUTSIDE SOURCE NOTES ON THE GENERAL NOTES AND LEGEND SHEET.4.WHEN THE SOURCE OF THE DETAIL IS A REVIEWING/REGULATORY AGENCY,FABRICATION AND INSTALLATION SHALL BE IN ACCORDANCE WITH APPLICABLEREQUIREMENTS AND SPECIFICATIONS. WHEN APPROPRIATE, SHOP DRAWINGS SHALLBE FORWARDED TO THE REVIEWING/REGULATORY AGENCY PRIOR TO FABRICATION.CONSTRUCTION DETAILS NOTES:1.THE FREDERICK WATER DETAILS SHOWN ON THIS SHEET TO BE USED BY PRIVATEFACILITIES. May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA220135.00-0A----->LAYOUT: C-1003 DETLYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-CNDSPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026DETAILS BY OTHERS DISCLAIMERNOTES REGARDING DETAILS BY OTHERS:1.DETAILS PREPARED BY OTHERS ARE IDENTIFIED AS SUCH BY WAY OF A TITLE BLOCK,REFERENCE, LOGO, OR OTHER NOTATION.2.WHERE AN ORIGINAL DETAIL BY OTHERS HAS BEEN MODIFIED, THE MODIFICATIONS AREIDENTIFIED BY REVISION CLOUDS.3.REFER TO OUTSIDE SOURCE NOTES ON THE GENERAL NOTES AND LEGEND SHEET.4.WHEN THE SOURCE OF THE DETAIL IS A REVIEWING/REGULATORY AGENCY,FABRICATION AND INSTALLATION SHALL BE IN ACCORDANCE WITH APPLICABLEREQUIREMENTS AND SPECIFICATIONS. WHEN APPROPRIATE, SHOP DRAWINGS SHALLBE FORWARDED TO THE REVIEWING/REGULATORY AGENCY PRIOR TO FABRICATION.C-1003CONSTRUCTIONDETAILS C-1004CORRESPONDENCE May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA220135.00-0A----->LAYOUT: C-1004 CORRESPONDENCEYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-CNDSPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026 C-1005PHOTOMETRICPLAN - FYI May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA220135.00-0A----->LAYOUT: C-1005 PHOTOMETRICYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-CNDSPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026 C-1006WATERMODEL May 08, 2026 DISCLAIMER This drawing and/or file has been prepared by Bohler at the request of the Project Owner or his Representative and is being provided solely as a convenience to the recipient. Bohler makes no representation regarding the suitability for the intended use by the recipient. Further, Bohler makes noPROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:PROJECT:FORM:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA220135.00-0A----->LAYOUT: C-1006 WATER MODELYG THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCYREVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTIONDOCUMENT UNLESS INDICATED OTHERWISE.SHEET NUMBER:SHEET TITLE:NJA220135.00-0AJDMGE04/29/2026P-CIVL-CNDSPROP.SITE PLANDOCUMENTSPROPOSEDDEVELOPMENT251 FRONT ROYAL PIKEWINCHESTER, VA 22602FREDERICK COUNTYSHAWNEE MAGISTERIAL DISTRICTPIN #: 64 08 000112REVISION 2 -REVISIONSREVDATECOMMENTDRAWN BYCHECKED BY03/27/2026SITE PLANRESUBMISSIONCRGE05/08/2026SITE PLAN 2NDRESUBMISSIONCRSN05/08/2026NOT APPROVED FORCONSTRUCTION12825 WORLDGATE DR. SUITE 700HERNDON, VIRGINIA 20170Phone:(703) 709-9500Fax:(703) 709-9501VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES BOHLER May 08, 2026 Know what's below.Call before you dig.ALWAYS CALL 811It's fast. It's free. It's the law.SHEILA MARIENALELic. No. 06590305/08/2026SHEILA MARIENALELic. No. 06590305/08/2026 LANDSCAPE SCHEDULE KEY QTY.BOTANICAL NAME COMMON NAME CAL.CONT. SHADE TREES PLO 65 PLATANUS OCCIDENTALIS AMERICAN SYCAMORE 2" CAL. / 8-10'B+B QPH 120 QUERCUS PHELLOS WILLOW OAK 2" CAL. / 8-10'B+B SUBTOTAL:185 EVERGREEN SHRUBS ICBUR 182 ILEX CORNUTA 'BURFORDII'BURFORD HOLLY 36" MIN.3 GAL. ICC 196 ILEX CRENATA 'COMPACTA'COMPACT JAPANESE HOLLY 36" MIN.3 GAL. IGC 273 ILEX GLABRA 'COMPACTA'DWARF INKBERRY HOLLY 36" MIN.3 GAL. JCH 109 JUNIPERUS CHINENSIS 'HETZII'HETZ JUNIPER 36" MIN.3 GAL. VR 125 VIBURNUM X RHYTIDOPHYLLUM LEATHERLEAF VIBURNUM 36" MIN.3 GAL. SUBTOTAL:885 NOTE: IF ANY DISCREPANCIES OCCUR BETWEEN THE AMOUNTS SHOWN IN THE PLAN AND THE PLANT LIST, THE PLAN WILL DICTATE.SSSSSSS D SSWWWWWWWWWWWSSD D D D D D D D SL SSSSSSD D TTTTTTTTTTTTTTTT EEEEEEEEEE DD D D D DFRONT ROYAL PIKE - U.S. ROUTE 522N46°13'28"E 367.43'COSTEL L O D R I V E 3 4 - 1 3 6 7 ELODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLOD LOD LOD LOD LOD LOD LODLODLODLOD LODLODLODLODLODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011LOWLOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOD LOD LOD LOD LOD LOD LOD LOD LOD LOWLOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW LOW LOW LOW LOW CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC CCCC L-101 OVERALL LANDSCAPE PLAN GRAD 1"=50' 0 5012.52550 SHEET L-102 SHEET L-103 SHEET L-106 SHEET L-104 SHEET L-105 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-LSCP-NJA220135.00-0A----->LAYOUT: L-101 OVERALL LANDSCAPE PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-LSCP PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 72171972072172272372 4 718719720721722723724719 718 20' FREDERICK WATER EASEMENT FRONT ROYAL PIKE - U.S. ROUTE 522LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOW LOW PROP LIGHT (TYP)PROP 5' SIDEWALKPROP ACCESSIBLE RAMP P P P P P P P P P P P P P P P17 IGC ^1 QPH ^1 PLO ^1 PLO ^1 PLO ^1 PLO ^1 PLO P4 QPH P4 QPH ^2 QPH ^2 QPH^2 QPH ^2 QPH ^2 QPH^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH P8 PLO P66 ICBUR P44 ICC LANDSCAPE SCHEDULE KEY QTY.BOTANICAL NAME COMMON NAME CAL.CONT. SHADE TREES PLO 65 PLATANUS OCCIDENTALIS AMERICAN SYCAMORE 2" CAL. / 8-10'B+B QPH 120 QUERCUS PHELLOS WILLOW OAK 2" CAL. / 8-10'B+B SUBTOTAL:185 EVERGREEN SHRUBS ICBUR 182 ILEX CORNUTA 'BURFORDII'BURFORD HOLLY 36" MIN.3 GAL. ICC 196 ILEX CRENATA 'COMPACTA'COMPACT JAPANESE HOLLY 36" MIN.3 GAL. IGC 273 ILEX GLABRA 'COMPACTA'DWARF INKBERRY HOLLY 36" MIN.3 GAL. JCH 109 JUNIPERUS CHINENSIS 'HETZII'HETZ JUNIPER 36" MIN.3 GAL. VR 125 VIBURNUM X RHYTIDOPHYLLUM LEATHERLEAF VIBURNUM 36" MIN.3 GAL. SUBTOTAL:885 NOTE: IF ANY DISCREPANCIES OCCUR BETWEEN THE AMOUNTS SHOWN IN THE PLAN AND THE PLANT LIST, THE PLAN WILL DICTATE. L-102 LANDSCAPE PLAN GRAD 1"=20' 0 2051020 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-LSCP-NJA220135.00-0A----->LAYOUT: L-102 LANDSCAPE PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-LSCP PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 MATCHLINE - SHEET L-103 1.PLANTING PROCEDURE. ALL REQUIRED TREES AND SHRUBS SHALL MEET THE SPECIFICATIONS AND PROCEDURES ESTABLISHED BY THE AMERICAN NURSERY AND LANDSCAPE ASSOCIATION. 1.1.ALL TREES SHALL BE PLANTED NO CLOSER THAN THREE FEET TO THE EDGE OF SIDEWALKS, CURB OR OTHER PAVEMENT. 1.2.DECIDUOUS TREES SHALL BE A MINIMUM OF TWO INCH CALIPER AT THE TIME OF PLANNING. 1.3.ONLY SINGLE STEM TREES SHALL BE PLANTED AS STREET TREES. 1.4.EVERGREEN TREES SHALL BE A MINIMUM OF FOUR FEET IN HEIGHT AT THE TIME OF PLANTING. SHRUBS SHALL BE A MINIMUM THREE GALLON CONTAINER AT THE TIME OF PLANTING. IN ADDITION TO THE THREE GALLON CONTAINER REQUIREMENT, PARKING LOT SCREENING SHRUBS SHALL BE A MINIMUM OF 36” IN HEIGHT AT TIME OF PLANTING AND BUFFER SHRUBS SHALL BE A MINIMUM OF 18” IN HEIGHT AT TIME OF PLANTING. SPACING OF PARKING LOT SCREENING SHRUBS SHALL BE NO GREATER THAN FOUR (4) FEET ON CENTER. 1.5.ONLY TREES HAVING A MATURE HEIGHT OF LESS THAN 20 FEET SHALL BE LOCATED UNDER OVERHEAD UTILITY LINES. 1.6.MEASUREMENT OF SIZE. CALIPER IS MEASURED SIX (6) INCHES ABOVE THE GROUND UP TO AND INCLUDING FOUR (4) INCH CALIPER SIZE, AND TWELVE (12) INCHES ABOVE THE GROUND FOR LARGER SIZES. DIAMETER AT BREAST HEIGHT (DBH) WILL BE MEASURED AT THE HEIGHT OF 54 INCHES FROM THE BASE OF THE TRUNK OR AS OTHERWISE ALLOWED IN THE GUIDE FOR PLANT APPRAISAL. 2.MAINTENANCE. THE OWNER, DEVELOPER, AND/OR BUILDER WHO IS RESPONSIBLE FOR PLANTING REQUIRED LANDSCAPING SHALL BE RESPONSIBLE FOR MAINTAINING IT IN A STATE OF GOOD HEALTH FOR ONE YEAR AFTER PLANTING. AFTER ONE YEAR, FROM THE DATE OCCUPANCY IS APPROVED, THE INDIVIDUAL PROPERTY OWNER AND/OR HOMEOWNER'S ASSOCIATION SHALL BECOME RESPONSIBLE FOR MAINTENANCE. AS LONG AS THE INTENT OF THIS SECTION IS MET, THE ZONING ADMINISTRATOR MAY WAIVE THE REQUIREMENT FOR LANDSCAPING ON INDIVIDUAL BUILDING LOTS WHEN A HAZARD OR NUISANCE EXISTS. 3.NO TREES OR SHRUBS SHALL BE PLACED IN FREDERICK WATER/ FCSA EASEMENTS. 4.ALL PLANTINGS WILL CONFORM TO THE ZONING ORDINANCE §165-203.02. LANDSCAPE NOTES 717718719720721722723718 717 71771771871972072172272372 4 718720721722718718 7207217227187197207 2 1 7 2 2 72371 6 71 6716 VARIABLE STORM DRAINAGE EASEMENT VARIABLE STORM DRAINAGE EASEMENTFRONT ROYAL PIKE - U.S. ROUTE 522LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODCOSTELL O D R I V E 3 4 - 1 3 6 7 E W E SNORTH ZONEVCS NAD83 /2011LOWLOWLOW LOWLOWLOWLOD LOD LOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD PROP ROWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWLOWPROP LIGHT (TYP) PROP SIGHT DISTANCE EASEMENT P P P P P P P P P ^1 QPH P27 ICBUR P17 ICBUR P31 ICC P27 ICBUR P17 ICBUR ^1 QPH ^1 QPH ^1 QPH ^2 QPH ^2 QPH^2 QPH ^1 QPH ^1 QPH 9 VR 8 JCH 8 JCH 7 VR 8 JCH 5 JCH 5 VR 5 JCH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH P3 QPH 4 JCH 19 JCH P1 QPH LANDSCAPE SCHEDULE KEY QTY.BOTANICAL NAME COMMON NAME CAL.CONT. SHADE TREES PLO 65 PLATANUS OCCIDENTALIS AMERICAN SYCAMORE 2" CAL. / 8-10'B+B QPH 120 QUERCUS PHELLOS WILLOW OAK 2" CAL. / 8-10'B+B SUBTOTAL:185 EVERGREEN SHRUBS ICBUR 182 ILEX CORNUTA 'BURFORDII'BURFORD HOLLY 36" MIN.3 GAL. ICC 196 ILEX CRENATA 'COMPACTA'COMPACT JAPANESE HOLLY 36" MIN.3 GAL. IGC 273 ILEX GLABRA 'COMPACTA'DWARF INKBERRY HOLLY 36" MIN.3 GAL. JCH 109 JUNIPERUS CHINENSIS 'HETZII'HETZ JUNIPER 36" MIN.3 GAL. VR 125 VIBURNUM X RHYTIDOPHYLLUM LEATHERLEAF VIBURNUM 36" MIN.3 GAL. SUBTOTAL:885 NOTE: IF ANY DISCREPANCIES OCCUR BETWEEN THE AMOUNTS SHOWN IN THE PLAN AND THE PLANT LIST, THE PLAN WILL DICTATE. L-103 LANDSCAPE PLAN GRAD 1"=20' 0 2051020 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-LSCP-NJA220135.00-0A----->LAYOUT: L-103 LANDSCAPE PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-LSCP PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 MATCHLINE - SHEETL-104MATCHLINE - SHEET L-102 1.PLANTING PROCEDURE. ALL REQUIRED TREES AND SHRUBS SHALL MEET THE SPECIFICATIONS AND PROCEDURES ESTABLISHED BY THE AMERICAN NURSERY AND LANDSCAPE ASSOCIATION. 1.1.ALL TREES SHALL BE PLANTED NO CLOSER THAN THREE FEET TO THE EDGE OF SIDEWALKS, CURB OR OTHER PAVEMENT. 1.2.DECIDUOUS TREES SHALL BE A MINIMUM OF TWO INCH CALIPER AT THE TIME OF PLANNING. 1.3.ONLY SINGLE STEM TREES SHALL BE PLANTED AS STREET TREES. 1.4.EVERGREEN TREES SHALL BE A MINIMUM OF FOUR FEET IN HEIGHT AT THE TIME OF PLANTING. SHRUBS SHALL BE A MINIMUM THREE GALLON CONTAINER AT THE TIME OF PLANTING. IN ADDITION TO THE THREE GALLON CONTAINER REQUIREMENT, PARKING LOT SCREENING SHRUBS SHALL BE A MINIMUM OF 36” IN HEIGHT AT TIME OF PLANTING AND BUFFER SHRUBS SHALL BE A MINIMUM OF 18” IN HEIGHT AT TIME OF PLANTING. SPACING OF PARKING LOT SCREENING SHRUBS SHALL BE NO GREATER THAN FOUR (4) FEET ON CENTER. 1.5.ONLY TREES HAVING A MATURE HEIGHT OF LESS THAN 20 FEET SHALL BE LOCATED UNDER OVERHEAD UTILITY LINES. 1.6.MEASUREMENT OF SIZE. CALIPER IS MEASURED SIX (6) INCHES ABOVE THE GROUND UP TO AND INCLUDING FOUR (4) INCH CALIPER SIZE, AND TWELVE (12) INCHES ABOVE THE GROUND FOR LARGER SIZES. DIAMETER AT BREAST HEIGHT (DBH) WILL BE MEASURED AT THE HEIGHT OF 54 INCHES FROM THE BASE OF THE TRUNK OR AS OTHERWISE ALLOWED IN THE GUIDE FOR PLANT APPRAISAL. 2.MAINTENANCE. THE OWNER, DEVELOPER, AND/OR BUILDER WHO IS RESPONSIBLE FOR PLANTING REQUIRED LANDSCAPING SHALL BE RESPONSIBLE FOR MAINTAINING IT IN A STATE OF GOOD HEALTH FOR ONE YEAR AFTER PLANTING. AFTER ONE YEAR, FROM THE DATE OCCUPANCY IS APPROVED, THE INDIVIDUAL PROPERTY OWNER AND/OR HOMEOWNER'S ASSOCIATION SHALL BECOME RESPONSIBLE FOR MAINTENANCE. AS LONG AS THE INTENT OF THIS SECTION IS MET, THE ZONING ADMINISTRATOR MAY WAIVE THE REQUIREMENT FOR LANDSCAPING ON INDIVIDUAL BUILDING LOTS WHEN A HAZARD OR NUISANCE EXISTS. 3.NO TREES OR SHRUBS SHALL BE PLACED IN FREDERICK WATER/ FCSA EASEMENTS. 4.ALL PLANTINGS WILL CONFORM TO THE ZONING ORDINANCE §165-203.02. LANDSCAPE NOTES S717 717 714714715715715 716 717 715 716 716 717 717 718 718 714 715 715716 716716 716718 71 6 71 6 7177 1 8 717 716 713716D D SLSLVARIABLE STORM DRAINAGE EASEMENT VARIABLE STORM DRAINAGE EASEMENT COSTEL L O D R I V E 3 4 - 1 3 6 7 E LOD LODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLOD LOD LODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011 LOD LOD LOD PROP ROW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW PROP FLUSH CURB PROP SIGHT DISTANCE EASEMENT PROP SIGHT DISTANCE EASEMENT P ^2 QPH ^2 QPH ^1 QPH P3 QPH ^2 QPH ^2 QPH 5 VR 5 JCH 13 IGC 9 VR 13 IGC 13 IGC ^1 PLO ^1 PLO 9 VR 13 IGC 11 IGC 9 VR 11 IGC 7 IGC 7 VR 7 IGC ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^1 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^1 PLO ^1 PLO P4 QPH LANDSCAPE SCHEDULE KEY QTY.BOTANICAL NAME COMMON NAME CAL.CONT. SHADE TREES PLO 65 PLATANUS OCCIDENTALIS AMERICAN SYCAMORE 2" CAL. / 8-10'B+B QPH 120 QUERCUS PHELLOS WILLOW OAK 2" CAL. / 8-10'B+B SUBTOTAL:185 EVERGREEN SHRUBS ICBUR 182 ILEX CORNUTA 'BURFORDII'BURFORD HOLLY 36" MIN.3 GAL. ICC 196 ILEX CRENATA 'COMPACTA'COMPACT JAPANESE HOLLY 36" MIN.3 GAL. IGC 273 ILEX GLABRA 'COMPACTA'DWARF INKBERRY HOLLY 36" MIN.3 GAL. JCH 109 JUNIPERUS CHINENSIS 'HETZII'HETZ JUNIPER 36" MIN.3 GAL. VR 125 VIBURNUM X RHYTIDOPHYLLUM LEATHERLEAF VIBURNUM 36" MIN.3 GAL. SUBTOTAL:885 NOTE: IF ANY DISCREPANCIES OCCUR BETWEEN THE AMOUNTS SHOWN IN THE PLAN AND THE PLANT LIST, THE PLAN WILL DICTATE. L-104 LANDSCAPE PLAN GRAD 1"=20' 0 2051020 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-LSCP-NJA220135.00-0A----->LAYOUT: L-104 LANDSCAPE PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-LSCP PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 MATCHLINE - SHEETL-103MATCHLINE - SHEETL-1051.PLANTING PROCEDURE. ALL REQUIRED TREES AND SHRUBS SHALL MEET THE SPECIFICATIONS AND PROCEDURES ESTABLISHED BY THE AMERICAN NURSERY AND LANDSCAPE ASSOCIATION. 1.1.ALL TREES SHALL BE PLANTED NO CLOSER THAN THREE FEET TO THE EDGE OF SIDEWALKS, CURB OR OTHER PAVEMENT. 1.2.DECIDUOUS TREES SHALL BE A MINIMUM OF TWO INCH CALIPER AT THE TIME OF PLANNING. 1.3.ONLY SINGLE STEM TREES SHALL BE PLANTED AS STREET TREES. 1.4.EVERGREEN TREES SHALL BE A MINIMUM OF FOUR FEET IN HEIGHT AT THE TIME OF PLANTING. SHRUBS SHALL BE A MINIMUM THREE GALLON CONTAINER AT THE TIME OF PLANTING. IN ADDITION TO THE THREE GALLON CONTAINER REQUIREMENT, PARKING LOT SCREENING SHRUBS SHALL BE A MINIMUM OF 36” IN HEIGHT AT TIME OF PLANTING AND BUFFER SHRUBS SHALL BE A MINIMUM OF 18” IN HEIGHT AT TIME OF PLANTING. SPACING OF PARKING LOT SCREENING SHRUBS SHALL BE NO GREATER THAN FOUR (4) FEET ON CENTER. 1.5.ONLY TREES HAVING A MATURE HEIGHT OF LESS THAN 20 FEET SHALL BE LOCATED UNDER OVERHEAD UTILITY LINES. 1.6.MEASUREMENT OF SIZE. CALIPER IS MEASURED SIX (6) INCHES ABOVE THE GROUND UP TO AND INCLUDING FOUR (4) INCH CALIPER SIZE, AND TWELVE (12) INCHES ABOVE THE GROUND FOR LARGER SIZES. DIAMETER AT BREAST HEIGHT (DBH) WILL BE MEASURED AT THE HEIGHT OF 54 INCHES FROM THE BASE OF THE TRUNK OR AS OTHERWISE ALLOWED IN THE GUIDE FOR PLANT APPRAISAL. 2.MAINTENANCE. THE OWNER, DEVELOPER, AND/OR BUILDER WHO IS RESPONSIBLE FOR PLANTING REQUIRED LANDSCAPING SHALL BE RESPONSIBLE FOR MAINTAINING IT IN A STATE OF GOOD HEALTH FOR ONE YEAR AFTER PLANTING. AFTER ONE YEAR, FROM THE DATE OCCUPANCY IS APPROVED, THE INDIVIDUAL PROPERTY OWNER AND/OR HOMEOWNER'S ASSOCIATION SHALL BECOME RESPONSIBLE FOR MAINTENANCE. AS LONG AS THE INTENT OF THIS SECTION IS MET, THE ZONING ADMINISTRATOR MAY WAIVE THE REQUIREMENT FOR LANDSCAPING ON INDIVIDUAL BUILDING LOTS WHEN A HAZARD OR NUISANCE EXISTS. 3.NO TREES OR SHRUBS SHALL BE PLACED IN FREDERICK WATER/ FCSA EASEMENTS. 4.ALL PLANTINGS WILL CONFORM TO THE ZONING ORDINANCE §165-203.02. LANDSCAPE NOTES SSSSSSSSS716 716710712713713716 714715716 708 709 710 711712713714 715715716716716716716716717717717716 717718 703704705706707708709710711712713714715715715716713714714714715714 716716 710 711 712 713 714 715 716 710713714715716716713 714714 703704705 706WWWWWWWWWWWSSSSSSSPROP GREASE TRAP D D D D D DSLSL SVARIABLE STORM DRAINAGE EASEMENT 20' STORM DRAINAGE EASEMENT D D TTTTTTTTTTEXTENT OF FREDERICK WATER COMBINED WATER AND SEWER EASEMENT. SEWER BEYOND THIS EASEMENT IS PRIVATELY OWNED AND MAINTAINED. W D D D COST E L L O D R I V E 3 4 - 1 3 6 7 ELODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011 PROP ROW PROP ROW LOWLOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW717PROP FLUSH CURB PROP SIGHT DISTANCE EASEMENT PROP SIGHT DISTANCE EASEMENT ^1 PLO 7 VR 7 IGC P1 PLO ^2 QPH ^1 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^2 QPH ^1 QPH ^2 PLO ^1 PLO ^1 PLO ^1 QPH 6 VR^2 QPH ^1 PLO ^2 QPH P26 VR P31 ICC P33 ICBUR 5 IGC 2 VR 4 IGC 2 VR ^2 QPH ^1 PLO ^1 PLO ^1 QPH P6 PLO P4 QPH 50 IGC P3 PLO P2 PLO P3 QPH P11 ICBUR LANDSCAPE SCHEDULE KEY QTY.BOTANICAL NAME COMMON NAME CAL.CONT. SHADE TREES PLO 65 PLATANUS OCCIDENTALIS AMERICAN SYCAMORE 2" CAL. / 8-10'B+B QPH 120 QUERCUS PHELLOS WILLOW OAK 2" CAL. / 8-10'B+B SUBTOTAL:185 EVERGREEN SHRUBS ICBUR 182 ILEX CORNUTA 'BURFORDII'BURFORD HOLLY 36" MIN.3 GAL. ICC 196 ILEX CRENATA 'COMPACTA'COMPACT JAPANESE HOLLY 36" MIN.3 GAL. IGC 273 ILEX GLABRA 'COMPACTA'DWARF INKBERRY HOLLY 36" MIN.3 GAL. JCH 109 JUNIPERUS CHINENSIS 'HETZII'HETZ JUNIPER 36" MIN.3 GAL. VR 125 VIBURNUM X RHYTIDOPHYLLUM LEATHERLEAF VIBURNUM 36" MIN.3 GAL. SUBTOTAL:885 NOTE: IF ANY DISCREPANCIES OCCUR BETWEEN THE AMOUNTS SHOWN IN THE PLAN AND THE PLANT LIST, THE PLAN WILL DICTATE. L-105 LANDSCAPE PLAN GRAD MATCHLINE - SHEET L-106 1"=20' 0 2051020MATCHLINE - SHEETL-104 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-LSCP-NJA220135.00-0A----->LAYOUT: L-105 LANDSCAPE PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-LSCP PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 1.PLANTING PROCEDURE. ALL REQUIRED TREES AND SHRUBS SHALL MEET THE SPECIFICATIONS AND PROCEDURES ESTABLISHED BY THE AMERICAN NURSERY AND LANDSCAPE ASSOCIATION. 1.1.ALL TREES SHALL BE PLANTED NO CLOSER THAN THREE FEET TO THE EDGE OF SIDEWALKS, CURB OR OTHER PAVEMENT. 1.2.DECIDUOUS TREES SHALL BE A MINIMUM OF TWO INCH CALIPER AT THE TIME OF PLANNING. 1.3.ONLY SINGLE STEM TREES SHALL BE PLANTED AS STREET TREES. 1.4.EVERGREEN TREES SHALL BE A MINIMUM OF FOUR FEET IN HEIGHT AT THE TIME OF PLANTING. SHRUBS SHALL BE A MINIMUM THREE GALLON CONTAINER AT THE TIME OF PLANTING. IN ADDITION TO THE THREE GALLON CONTAINER REQUIREMENT, PARKING LOT SCREENING SHRUBS SHALL BE A MINIMUM OF 36” IN HEIGHT AT TIME OF PLANTING AND BUFFER SHRUBS SHALL BE A MINIMUM OF 18” IN HEIGHT AT TIME OF PLANTING. SPACING OF PARKING LOT SCREENING SHRUBS SHALL BE NO GREATER THAN FOUR (4) FEET ON CENTER. 1.5.ONLY TREES HAVING A MATURE HEIGHT OF LESS THAN 20 FEET SHALL BE LOCATED UNDER OVERHEAD UTILITY LINES. 1.6.MEASUREMENT OF SIZE. CALIPER IS MEASURED SIX (6) INCHES ABOVE THE GROUND UP TO AND INCLUDING FOUR (4) INCH CALIPER SIZE, AND TWELVE (12) INCHES ABOVE THE GROUND FOR LARGER SIZES. DIAMETER AT BREAST HEIGHT (DBH) WILL BE MEASURED AT THE HEIGHT OF 54 INCHES FROM THE BASE OF THE TRUNK OR AS OTHERWISE ALLOWED IN THE GUIDE FOR PLANT APPRAISAL. 2.MAINTENANCE. THE OWNER, DEVELOPER, AND/OR BUILDER WHO IS RESPONSIBLE FOR PLANTING REQUIRED LANDSCAPING SHALL BE RESPONSIBLE FOR MAINTAINING IT IN A STATE OF GOOD HEALTH FOR ONE YEAR AFTER PLANTING. AFTER ONE YEAR, FROM THE DATE OCCUPANCY IS APPROVED, THE INDIVIDUAL PROPERTY OWNER AND/OR HOMEOWNER'S ASSOCIATION SHALL BECOME RESPONSIBLE FOR MAINTENANCE. AS LONG AS THE INTENT OF THIS SECTION IS MET, THE ZONING ADMINISTRATOR MAY WAIVE THE REQUIREMENT FOR LANDSCAPING ON INDIVIDUAL BUILDING LOTS WHEN A HAZARD OR NUISANCE EXISTS. 3.NO TREES OR SHRUBS SHALL BE PLACED IN FREDERICK WATER/ FCSA EASEMENTS. 4.ALL PLANTINGS WILL CONFORM TO THE ZONING ORDINANCE §165-203.02. LANDSCAPE NOTES SSSSSSSSSSSSSSS S S 715 716717 717718718718718 716716716717718 717718 719 720 721 722 718 719 720 719 71371471 4 714715715715716717718 7167177187197 1 9 719 710711712715714 718 719 720 717 718 D SSWWWWWWWWWWWWWWWWWWWWWWWWSSSL SL SL SSSSSSSSSSSSSSSS 20' FREDERICK WATER EASEMENT (TYP) 20' FREDERICK WATER EASEMENT DTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT T T E E EEEEEEEEEEEEEEEE E EEEEEEEEEEEEEE DD SL PROP SAND SEPARATOR D D PROP 8" PVCWW20' FREDERICK WATER EASEMENT LODLODLODLODLODLODLODLOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODW E SNORTH ZONEVCS NAD83 /2011 FUEL ENTRY FUEL ENTRY 20' FREDERICK WATER EASEMENT FOR FUTURE WATERMAIN EXTENSION (TYP) P ^1 PLO P26 JCH P31 VR P26 JCH^1 PLO ^1 PLO P1 PLOP2 PLO ^2 PLO 47 ICC ^1 PLO ^1 PLO ^8 PLO P1 PLO 3 VR 8 IGC 32 IGC P6 PLO 8 IGC 63 IGC 50 IGC P9 PLO LANDSCAPE SCHEDULE KEY QTY.BOTANICAL NAME COMMON NAME CAL.CONT. SHADE TREES PLO 65 PLATANUS OCCIDENTALIS AMERICAN SYCAMORE 2" CAL. / 8-10'B+B QPH 120 QUERCUS PHELLOS WILLOW OAK 2" CAL. / 8-10'B+B SUBTOTAL:185 EVERGREEN SHRUBS ICBUR 182 ILEX CORNUTA 'BURFORDII'BURFORD HOLLY 36" MIN.3 GAL. ICC 196 ILEX CRENATA 'COMPACTA'COMPACT JAPANESE HOLLY 36" MIN.3 GAL. IGC 273 ILEX GLABRA 'COMPACTA'DWARF INKBERRY HOLLY 36" MIN.3 GAL. JCH 109 JUNIPERUS CHINENSIS 'HETZII'HETZ JUNIPER 36" MIN.3 GAL. VR 125 VIBURNUM X RHYTIDOPHYLLUM LEATHERLEAF VIBURNUM 36" MIN.3 GAL. SUBTOTAL:885 NOTE: IF ANY DISCREPANCIES OCCUR BETWEEN THE AMOUNTS SHOWN IN THE PLAN AND THE PLANT LIST, THE PLAN WILL DICTATE. GRAD 1"=20' 0 2051020 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-LSCP-NJA220135.00-0A----->LAYOUT: L-106 LANDSCAPE PLANYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-LSCP PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 MATCHLINE - SHEET L-105 1.PLANTING PROCEDURE. ALL REQUIRED TREES AND SHRUBS SHALL MEET THE SPECIFICATIONS AND PROCEDURES ESTABLISHED BY THE AMERICAN NURSERY AND LANDSCAPE ASSOCIATION. 1.1.ALL TREES SHALL BE PLANTED NO CLOSER THAN THREE FEET TO THE EDGE OF SIDEWALKS, CURB OR OTHER PAVEMENT. 1.2.DECIDUOUS TREES SHALL BE A MINIMUM OF TWO INCH CALIPER AT THE TIME OF PLANNING. 1.3.ONLY SINGLE STEM TREES SHALL BE PLANTED AS STREET TREES. 1.4.EVERGREEN TREES SHALL BE A MINIMUM OF FOUR FEET IN HEIGHT AT THE TIME OF PLANTING. SHRUBS SHALL BE A MINIMUM THREE GALLON CONTAINER AT THE TIME OF PLANTING. IN ADDITION TO THE THREE GALLON CONTAINER REQUIREMENT, PARKING LOT SCREENING SHRUBS SHALL BE A MINIMUM OF 36” IN HEIGHT AT TIME OF PLANTING AND BUFFER SHRUBS SHALL BE A MINIMUM OF 18” IN HEIGHT AT TIME OF PLANTING. SPACING OF PARKING LOT SCREENING SHRUBS SHALL BE NO GREATER THAN FOUR (4) FEET ON CENTER. 1.5.ONLY TREES HAVING A MATURE HEIGHT OF LESS THAN 20 FEET SHALL BE LOCATED UNDER OVERHEAD UTILITY LINES. 1.6.MEASUREMENT OF SIZE. CALIPER IS MEASURED SIX (6) INCHES ABOVE THE GROUND UP TO AND INCLUDING FOUR (4) INCH CALIPER SIZE, AND TWELVE (12) INCHES ABOVE THE GROUND FOR LARGER SIZES. DIAMETER AT BREAST HEIGHT (DBH) WILL BE MEASURED AT THE HEIGHT OF 54 INCHES FROM THE BASE OF THE TRUNK OR AS OTHERWISE ALLOWED IN THE GUIDE FOR PLANT APPRAISAL. 2.MAINTENANCE. THE OWNER, DEVELOPER, AND/OR BUILDER WHO IS RESPONSIBLE FOR PLANTING REQUIRED LANDSCAPING SHALL BE RESPONSIBLE FOR MAINTAINING IT IN A STATE OF GOOD HEALTH FOR ONE YEAR AFTER PLANTING. AFTER ONE YEAR, FROM THE DATE OCCUPANCY IS APPROVED, THE INDIVIDUAL PROPERTY OWNER AND/OR HOMEOWNER'S ASSOCIATION SHALL BECOME RESPONSIBLE FOR MAINTENANCE. AS LONG AS THE INTENT OF THIS SECTION IS MET, THE ZONING ADMINISTRATOR MAY WAIVE THE REQUIREMENT FOR LANDSCAPING ON INDIVIDUAL BUILDING LOTS WHEN A HAZARD OR NUISANCE EXISTS. 3.NO TREES OR SHRUBS SHALL BE PLACED IN FREDERICK WATER/ FCSA EASEMENTS. 4.ALL PLANTINGS WILL CONFORM TO THE ZONING ORDINANCE §165-203.02. LANDSCAPE NOTES L-106 LANDSCAPE PLAN P P P P P P PP P P P P P P P P P P P P P P P P P I LANDSCAPE SCHEDULE KEY QTY.BOTANICAL NAME COMMON NAME CAL.CONT. SHADE TREES PLO 65 PLATANUS OCCIDENTALIS AMERICAN SYCAMORE 2" CAL. / 8-10'B+B QPH 120 QUERCUS PHELLOS WILLOW OAK 2" CAL. / 8-10'B+B SUBTOTAL:185 EVERGREEN SHRUBS ICBUR 182 ILEX CORNUTA 'BURFORDII'BURFORD HOLLY 36" MIN.3 GAL. ICC 196 ILEX CRENATA 'COMPACTA'COMPACT JAPANESE HOLLY 36" MIN.3 GAL. IGC 273 ILEX GLABRA 'COMPACTA'DWARF INKBERRY HOLLY 36" MIN.3 GAL. JCH 109 JUNIPERUS CHINENSIS 'HETZII'HETZ JUNIPER 36" MIN.3 GAL. VR 125 VIBURNUM X RHYTIDOPHYLLUM LEATHERLEAF VIBURNUM 36" MIN.3 GAL. SUBTOTAL:885 NOTE: IF ANY DISCREPANCIES OCCUR BETWEEN THE AMOUNTS SHOWN IN THE PLAN AND THE PLANT LIST, THE PLAN WILL DICTATE. IMPERVIOUS AREA 631,896 SF DESCRIPTION REQUIRED TREES (1/2,000 SF X 100,000 SF) 157 PERIMETER LANDSCAPING SECTION 165-202.01.D.13 PARKING AREA 445,617 SF 76 TREES INTERIOR LANDSCAPING SECTION 165-202.01.D.13.b. PARKING SPACES 759 SPACES "P" SYMBOLS INDICATE SPECIES USED TO FULFIL THIS REQUIREMENT TREES (1/5,000 SF X 527,842 SF) PLANTING AREA RATIO 5% 22,831 SF "^" SYMBOLS INDICATE SPECIES USED TO FULFIL THIS REQUIREMENT TOTAL 157 A CONTINUOUS ROW OF 3' TALL EVERGREEN SHRUBS HAVE BEEN PROVIDED IN FRONT OF ALL PARKING BAYS. EXISTING PROPOSED TOTAL 50 107 157 55 55 102 102 CALIPER (IN) EXISTING TREE PERIMETER LANDSCAPING SECTION 165-203.01.C QUANTITY TREE CREDIT TOTAL CREDIT 4" TO 6" 7" TO 12" 13" TO 18" 19" TO 29" OVER 30" 0 1 2 16 6 1 2 3 4 5 0 2 6 68 30 "P" SYMBOLS INDICATE SPECIES USED TO FULFIL THIS REQUIREMENT TOTAL 25 NA 106 CALIPER (IN) EXISTING TREE INTERIOR LANDSCAPING SECTION 165-203.01.C QUANTITY TREE CREDIT TOTAL CREDIT 4" TO 6" 7" TO 12" 13" TO 18" 19" TO 29" OVER 30" 0 0 0 1 0 1 2 3 4 5 0 0 0 4 0 "I" SYMBOLS INDICATE SPECIES USED TO FULFIL THIS REQUIREMENT TOTAL 1 NA 4 DESCRIPTION REQUIRED PLANTING AREA (445,714 SF X 5%)32,853 SF (7.19%) TREES (1/10 X 791) EXISTING PROPOSED TOTAL NA 1341304 May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-LSCP-NJA220135.00-0A----->LAYOUT: L-107 LANDSCAPE COMPLIANCEYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-LSCP PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 L-107 LANDSCAPE COMPLIANCE GRAD 1"=100' 0 1002550100 OVERALL IMPERVIOUS AREA HATCH LEGEND OVERALL PARKING LOT AREA HATCH LEGEND INTERIOR PARKING LOT LANDSCAPE AREA 1"=100' 0 1002550100 OVERALL IMPERVIOUS AREA INSET PLAN SCALE: 1" = 100 OVERALL INTERIOR PARKING LOT INSET PLAN SCALE: 1" = 100' May 08, 2026DISCLAIMERPROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR M:\NJ\2022\NJA220135.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-LSCP-NJA220135.00-0A----->LAYOUT: L-108 LANDSCAPE NOTES AND DETLYGTHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA220135.00-0A JDM GE 04/29/2026 P-CIVL-LSCP PROP. SITE PLAN DOCUMENTS PROPOSED DEVELOPMENT 251 FRONT ROYAL PIKE WINCHESTER, VA 22602 FREDERICK COUNTY SHAWNEE MAGISTERIAL DISTRICT PIN #: 64 08 0001 1 2 REVISION 2 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 03/27/2026 SITE PLAN RESUBMISSION CR GE 05/08/2026 SITE PLAN 2ND RESUBMISSION CR SN 05/08/2026 NOT APPROVED FOR CONSTRUCTION 12825 WORLDGATE DR. SUITE 700 HERNDON, VIRGINIA 20170 Phone:(703) 709-9500 Fax:(703) 709-9501 VA@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER May 08, 2026Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. SHEILA MARIE NALE Lic. No. 065903 05/08/2026 L-108 LANDSCAPE NOTES AND DETAILS GRAD TREE PLANTING ON SLOPE DETAIL NOT TO SCALE EXISTING GRADE DO NOT WRAP TRUNK PREPARED SOIL FOR TREES 1 PART PEAT MOSS 1 PART COW MANURE 3 PARTS TOPSOIL UNDISTURBED SUBGRADE TAMP SOIL SOLIDLY AROUND BASE OF ROOT BALL 12" SET ROOT BALL ON FIRM PAD IN BOTTOM OF HOLE REMOVE THE TOP 1/3 OF THE WIRE BASKET IF PRESENT. ANY AND ALL TWINE SHALL BE REMOVED FROM THE TREE BEFORE BACKFILLING. BURLAP SHALL BE FOLDED BACK INTO PLANTING HOLE BEFORE PLANTING ADD 3 TO 4" OF WELL-COMPOSTED LEAVES OR RECYCLED YARD WASTE TO BED AND TILL INTO TOP 6" OF PREPARED SOIL. 3" THICK LAYER OF DARK BROWN DOUBLE SHREDDED HARDWOOD MULCH 4" BUILT-UP EARTH SAUCER SET ROOT BALL FLUSH TO GRADE OR SEVERAL INCHES HIGHER IN POORLY DRAINING SOILS. ONLY TREES WITH ONE MAIN LEADER SHALL BE PURCHASED. DO NOT PRUNE TREE AT PLANTING UNLESS DIRECTED TO BY PROJECT LANDSCAPE ARCHITECT 2" DIA. HARDWOOD STAKES 2/3 TREE HT. 2 PER TREE 12 GAUGE GALVANIZED WIRE GUYS TWISTED REINFORCED RUBBER HOSE (1/2" DIA.) NOTE: TREE STAKING TO BE REMOVED AFTER 2 GROWING SEASONS B&B CONTAINER FINISHED GRADE REFERENCE: ARCHITECTURAL GRAPHIC STANDARDS 1998 CUMULATIVE SUPPLEMENT NOT TO SCALE 8-12" 24" MINIMUM DECIDUOUS AND EVERGREEN SHRUB PLANTING DETAIL 3" THICK LAYER OF DARK BROWN DOUBLE SHREDDED HARDWOOD MULCH PLANT SHALL BE TRANSPLANTED AT THE SAME GRADE AS IT BORE IN THE NURSERY PLOT PRIOR TO BALLING AND BURLAPPING. FOR CONTAINER-GROWN SHRUBS, USE FINGER OR SMALL HAND TOOLS TO PULL THE ROOTS OUT OF THE OUTER LAYER OF POTTING SOIL; THEN CUT OR PULL APART ANY ROOTS THAT CIRCLE THE PERIMETER OF THE CONTAINER PLANTING MIX: 1 PART PEAT MOSS 1 PART COW MANURE 3 PARTS TOPSOIL PLANTING MIXTURE WILL CHANGE WITH SOIL CONDITIONS BEFORE PLANTING, ADD 3 TO 4" OF WELL-COMPOSTED LEAVES AND RECYCLED YARD WASTE TO BED AND TILL INTO TOP 6" OF PREPARED SOIL PLACE SHRUB ON FIRM SOIL IN BOTTOM OF HOLE. UNDISTURBED SUBGRADE SOIL SURFACE ROUGHENED TO BIND WITH NEW SOIL. REMOVE THE TOP 1/3 OF THE WIRE BASKET IF PRESENT. ANY AND ALL TWINE SHALL BE REMOVED FROM THE SHRUB BEFORE BACKFILLING. BURLAP SHALL BE FOLDED BACK INTO PLANTING HOLE EVERGREEN TREE PLANTING DETAIL NOT TO SCALE REFERENCE: ARCHITECTURAL GRAPHIC STANDARDS 1998 CUMULATIVE SUPPLEMENT. 4" BUILT-UP EARTH SAUCER 4-6" DEEPER THAN ROOT BALL BEFORE PLANTING ADD 3 TO 4" OF WELL-COMPOSTED LEAVES OR RECYCLED YARD WASTE TO BED AND TILL INTO TOP 6" OF PREPARED SOIL. SET ROOT BALL FLUSH TO GRADE OR SEVERAL INCHES HIGHER IN POORLY DRAINING SOILS. SET ROOT BALL ON FIRM PAD IN BOTTOM OF HOLE 3" THICK LAYER OF DARK BROWN DOUBLE SHREDDED HARDWOOD MULCH ONLY TREES WITH ONE MAIN LEADER SHALL BE PURCHASED. DO NOT PRUNE TREE AT PLANTING UNLESS DIRECTED TO BY PROJECT LANDSCAPE ARCHITECT FOLD BURLAP AWAY FROM TOP OF ROOT BALL PREPARE WIDTH OF PLANTING HOLE 6 FT OR TWICE THE WIDTH OF THE ROOT BALL; WHICHEVER IS GREATER PREPARED SOIL FOR TREES 1 PART PEAT MOSS 1 PART COW MANURE 3 PARTS TOPSOIL UNDISTURBED SUBGRADE DIG WIDE, SHALLOW HOLE WITH TAMPED SIDES TAMP SOIL SOLIDLY AROUND BASE OF ROOT BALL DO NOT STAKE OR WRAP TRUNK REMOVE THE TOP 1/3 OF THE WIRE BASKET IF PRESENT. ANY AND ALL TWINE SHALL BE REMOVED FROM THE TREE BEFORE BACKFILLING. BURLAP SHALL BE FOLDED BACK INTO PLANTING HOLE NOT TO SCALE EXISTING SUBSOILMINIMUM 6" TOPSOIL FINISHED GRADE PERENNIAL/GROUND COVER PLANTING DETAIL 3" THICK LAYER OF DARK BROWN DOUBLE SHREDDED HARDWOOD MULCH D DD TYPICAL PERENNIAL AND GROUND COVER SPACING & LAYOUT PLANT MATERIAL SPACED AS SPECIFIED. SEE LANDSCAPE SCHEDULE FOR PROPOSED SPACING. INCORPORATE 2" OF PEAT INTO 6" OF PLANTING MIXTURE, AS SPECIFIED D= PROPOSED ON CENTER (O.C.) SPACING SEE LANDSCAPE SCHEDULE FOR FOR REQUIRED SPACING TYPICAL PERENNIAL AND GROUND COVER PLANTING DECIDUOUS TREE PLANTING DETAIL 4" BUILT-UP EARTH SAUCER BEFORE PLANTING ADD 3 TO 4" OF WELL-COMPOSTED LEAVES OR RECYCLED YARD WASTE TO BED AND TILL INTO TOP 6" OF PREPARED SOIL. 4-6" DEEPER THAN ROOT BALL REFERENCE: ARCHITECTURAL GRAPHIC STANDARDS 1998 CUMULATIVE SUPPLEMENT. NOT TO SCALE 3" THICK LAYER OF DARK BROWN DOUBLE SHREDDED HARDWOOD MULCH TAMP SOIL SOLIDLY AROUND BASE OF ROOT BALL DIG WIDE, SHALLOW HOLE WITH TAMPED SIDES ONLY TREES WITH ONE MAIN LEADER SHALL BE PURCHASED. DO NOT PRUNE TREE AT PLANTING UNLESS DIRECTED TO BY PROJECT LANDSCAPE ARCHITECT SET ROOT BALL FLUSH TO GRADE OR SEVERAL INCHES HIGHER IN POORLY DRAINING SOILS. FOLD BURLAP AWAY FROM TOP OF ROOT BALL SET ROOT BALL ON FIRM PAD IN BOTTOM OF HOLE REMOVE THE TOP 1/3 OF THE WIRE BASKET IF PRESENT. ANY AND ALL TWINE SHALL BE REMOVED FROM THE TREE BEFORE BACKFILLING. BURLAP SHALL BE FOLDED BACK INTO PLANTING HOLE DO NOT STAKE OR WRAP TRUNK PREPARED SOIL FOR TREES 1 PART PEAT MOSS 1 PART COW MANURE 3 PARTS TOPSOIL UNDISTURBED SUBGRADE PREPARE WIDTH OF PLANTING HOLE 6 FT OR TWICE THE WIDTH OF THE ROOT BALL; WHICHEVER IS GREATER LANDSCAPE SPECIFICATIONS 1. SCOPE OF WORK: THE LANDSCAPE CONTRACTOR SHALL BE REQUIRED TO PERFORM ALL CLEARING, FINISHED GRADING, SOIL PREPARATION, PERMANENT SEEDING OR SODDING, PLANTING AND MULCHING INCLUDING ALL LABOR, MATERIALS, TOOLS AND EQUIPMENT NECESSARY FOR THE COMPLETION OF THIS PROJECT, UNLESS OTHERWISE CONTRACTED BY THE GENERAL CONTRACTOR. 2. MATERIALS A.GENERAL - ALL HARDSCAPE MATERIALS SHALL MEET OR EXCEED SPECIFICATIONS AS OUTLINED IN THE STATE DEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS. B.TOPSOIL - NATURAL, FRIABLE, LOAMY SILT SOIL HAVING AN ORGANIC CONTENT NOT LESS THAN 5%, A PH RANGE BETWEEN 4.5-7.0. IT SHALL BE FREE OF DEBRIS, ROCKS LARGER THAN ONE INCH (1"), WOOD, ROOTS, VEGETABLE MATTER AND CLAY CLODS. C.LAWN - ALL DISTURBED AREAS ARE TO BE TREATED WITH A MINIMUM SIX INCH (6") THICK LAYER OF TOPSOIL, OR AS DIRECTED BY THE LOCAL ORDINANCE OR CLIENT, AND SEEDED OR SODDED IN ACCORDANCE WITH THE PERMANENT STABILIZATION METHODS INDICATED WITHIN THE SOIL EROSION AND SEDIMENT CONTROL NOTES. 1.1.LAWN SEED MIXTURE SHALL BE FRESH, CLEAN NEW CROP SEED. 1.2.SOD SHALL BE STRONGLY ROOTED, WEED AND DISEASE/PEST FREE WITH A UNIFORM THICKNESS. 1.3.SOD INSTALLED ON SLOPES GREATER THAN 4:1 SHALL BE PEGGED TO HOLD SOD IN PLACE. D.MULCH - THE MULCH AROUND THE PERIMETER OF THE BUILDING SHALL BE A 3" LAYER OF DOUBLE SHREDDED BLACK CEDAR MULCH ONLY. ALL OTHER AREAS SHALL BE MULCHED WITH A 3" LAYER OF DOUBLE SHREDDED DARK BROWN HARDWOOD BARK MULCH, UNLESS OTHERWISE STATED ON THE LANDSCAPE PLAN. E.FERTILIZER 1.1.FERTILIZER SHALL BE DELIVERED TO THE SITE MIXED AS SPECIFIED IN THE ORIGINAL UNOPENED STANDARD BAGS SHOWING WEIGHT, ANALYSIS AND NAME OF MANUFACTURER. FERTILIZER SHALL BE STORED IN A WEATHERPROOF PLACE SO THAT IT CAN BE KEPT DRY PRIOR TO USE. 1.2.FOR THE PURPOSE OF BIDDING, ASSUME THAT FERTILIZER SHALL BE 10% NITROGEN, 6% PHOSPHORUS AND 4% POTASSIUM BY WEIGHT. A FERTILIZER SHOULD NOT BE SELECTED WITHOUT A SOIL TEST PERFORMED BY A CERTIFIED SOIL LABORATORY. F.PLANT MATERIAL 1.1.ALL PLANTS SHALL IN ALL CASES CONFORM TO THE REQUIREMENTS OF THE "AMERICAN STANDARD FOR NURSERY STOCK" (ANSI Z60.1), LATEST EDITION, AS PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION. 1.2.IN ALL CASES, BOTANICAL NAMES SHALL TAKE PRECEDENCE OVER COMMON NAMES FOR ANY AND ALL PLANT MATERIAL. 1.3.PLANTS SHALL BE LEGIBLY TAGGED WITH THE PROPER NAME AND SIZE. TAGS ARE TO REMAIN ON AT LEAST ONE PLANT OF EACH SPECIES FOR VERIFICATION PURPOSES DURING THE FINAL INSPECTION. 1.4.TREES WITH ABRASION OF THE BARK, SUN SCALDS, DISFIGURATION OR FRESH CUTS OF LIMBS OVER 1¼", WHICH HAVE NOT BEEN COMPLETELY CALLUSED, SHALL BE REJECTED.PLANTS SHALL NOT BE BOUND WITH WIRE OR ROPE AT ANY TIME SO AS TO DAMAGE THE BARK OR BREAK BRANCHES. 1.5.ALL PLANTS SHALL BE TYPICAL OF THEIR SPECIES OR VARIETY AND SHALL HAVE A NORMAL HABIT OF GROWTH: WELL DEVELOPED BRANCHES, DENSELY FOLIATED, VIGOROUS ROOT SYSTEMS AND BE FREE OF DISEASE, INSECTS, PESTS, EGGS OR LARVAE. 1.6.CALIPER MEASUREMENTS OF NURSERY GROWN TREES SHALL BE TAKEN AT A POINT ON THE TRUNK SIX INCHES (6") ABOVE THE NATURAL GRADE FOR TREES UP TO AND INCLUDING A FOUR INCH (4") CALIPER SIZE. IF THE CALIPER AT SIX INCHES (6") ABOVE THE GROUND EXCEEDS FOUR INCHES (4") IN CALIPER, THE CALIPER SHOULD BE MEASURED AT A POINT 12" ABOVE THE NATURAL GRADE. 1.7.SHRUBS SHALL BE MEASURED TO THE AVERAGE HEIGHT OR SPREAD OF THE SHRUB, AND NOT TO THE LONGEST BRANCH. 1.8.TREES AND SHRUBS SHALL BE HANDLED WITH CARE BY THE ROOT BALL. 3. GENERAL WORK PROCEDURES A.CONTRACTOR TO UTILIZE WORKMANLIKE INDUSTRY STANDARDS IN PERFORMING ALL LANDSCAPE CONSTRUCTION. THE SITE IS TO BE LEFT IN A CLEAN STATE AT THE END OF EACH WORKDAY. ALL DEBRIS, MATERIALS AND TOOLS SHALL BE PROPERLY STORED, STOCKPILED OR DISPOSED OF. B.WASTE MATERIALS AND DEBRIS SHALL BE COMPLETELY DISPOSED OF AT THE CONTRACTOR'S EXPENSE. DEBRIS SHALL NOT BE BURIED, INCLUDING ORGANIC MATERIALS, BUT SHALL BE REMOVED COMPLETELY FROM THE SITE. 4. SITE PREPARATIONS A.BEFORE AND DURING PRELIMINARY GRADING AND FINISHED GRADING, ALL WEEDS AND GRASSES SHALL BE DUG OUT BY THE ROOTS AND DISPOSED OF IN ACCORDANCE WITH GENERAL WORK PROCEDURES OUTLINED HEREIN. B.ALL EXISTING TREES TO REMAIN SHALL BE PRUNED TO REMOVE ANY DAMAGED BRANCHES. THE ENTIRE LIMB OF ANY DAMAGED BRANCH SHALL BE CUT OFF AT THE TRUNK. CONTRACTOR SHALL ENSURE THAT CUTS ARE SMOOTH AND STRAIGHT. ANY EXPOSED ROOTS SHALL BE CUT BACK WITH CLEAN, SHARP TOOLS AND TOPSOIL SHALL BE PLACED AROUND THE REMAINDER OF THE ROOTS. EXISTING TREES SHALL BE MONITORED ON A REGULAR BASIS FOR ADDITIONAL ROOT OR BRANCH DAMAGE AS A RESULT OF CONSTRUCTION. ROOTS SHALL NOT BE LEFT EXPOSED FOR MORE THAN ONE (1) DAY. CONTRACTOR SHALL WATER EXISTING TREES AS NEEDED TO PREVENT SHOCK OR DECLINE. C.CONTRACTOR SHALL ARRANGE TO HAVE A UTILITY STAKE-OUT TO LOCATE ALL UNDERGROUND UTILITIES PRIOR TO INSTALLATION OF ANY LANDSCAPE MATERIAL. UTILITY COMPANIES SHALL BE CONTACTED THREE (3) DAYS PRIOR TO THE BEGINNING OF WORK. 5. TREE PROTECTION A.CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING TREES TO REMAIN. A TREE PROTECTION ZONE SHALL BE ESTABLISHED AT THE DRIP LINE OR 15 FEET FROM THE TRUNK OR AT THE LIMIT OF CONSTRUCTION DISTURBANCE, WHICHEVER IS GREATER. LOCAL STANDARDS THAT MAY REQUIRE A MORE STRICT TREE PROTECTION ZONE SHALL BE HONORED. B.A FORTY-EIGHT INCH (48") HIGH WOODEN SNOW FENCE OR ORANGE COLORED HIGH-DENSITY 'VISI-FENCE', OR APPROVED EQUAL, MOUNTED ON STEEL POSTS SHALL BE PLACED ALONG THE BOUNDARY OF THE TREE PROTECTION ZONE. POSTS SHALL BE LOCATED AT A MAXIMUM OF EIGHT FEET (8') ON CENTER OR AS INDICATED WITHIN THE TREE PROTECTION DETAIL. C.WHEN THE TREE PROTECTION FENCING HAS BEEN INSTALLED, IT SHALL BE INSPECTED BY THE APPROVING AGENCY PRIOR TO DEMOLITION, GRADING, TREE CLEARING OR ANY OTHER CONSTRUCTION. THE FENCING ALONG THE TREE PROTECTION ZONE SHALL BE REGULARLY INSPECTED BY THE LANDSCAPE CONTRACTOR AND MAINTAINED UNTIL ALL CONSTRUCTION ACTIVITY HAS BEEN COMPLETED. D.AT NO TIME SHALL MACHINERY, DEBRIS, FALLEN TREES OR OTHER MATERIALS BE PLACED, STOCKPILED OR LEFT STANDING IN THE TREE PROTECTION ZONE. 6. SOIL MODIFICATIONS A.CONTRACTOR SHALL ATTAIN A SOIL TEST FOR ALL AREAS OF THE SITE PRIOR TO CONDUCTING ANY PLANTING. SOIL TESTS SHALL BE PERFORMED BY A CERTIFIED SOIL LABORATORY. B.LANDSCAPE CONTRACTOR SHALL REPORT ANY SOIL OR DRAINAGE CONDITIONS CONSIDERED DETRIMENTAL TO THE GROWTH OF PLANT MATERIAL. SOIL MODIFICATIONS, AS SPECIFIED HEREIN, MAY NEED TO BE CONDUCTED BY THE LANDSCAPE CONTRACTOR DEPENDING ON SITE CONDITIONS. C.THE FOLLOWING AMENDMENTS AND QUANTITIES ARE APPROXIMATE AND ARE FOR BIDDING PURPOSES ONLY. COMPOSITION OF AMENDMENTS SHOULD BE REVISED DEPENDING ON THE OUTCOME OF A TOPSOIL ANALYSIS PERFORMED BY A CERTIFIED SOIL LABORATORY. 1.1.TO INCREASE A SANDY SOIL'S ABILITY TO RETAIN WATER AND NUTRIENTS, THOROUGHLY TILL ORGANIC MATTER INTO THE TOP 6-12". USE COMPOSTED BARK, COMPOSTED LEAF MULCH OR PEAT MOSS. ALL PRODUCTS SHOULD BE COMPOSTED TO A DARK COLOR AND BE FREE OF PIECES WITH IDENTIFIABLE LEAF OR WOOD STRUCTURE. AVOID MATERIAL WITH A PH HIGHER THAN 7.5. 1.2.TO INCREASE DRAINAGE, MODIFY HEAVY CLAY OR SILT (MORE THAN 40% CLAY OR SILT) BY ADDING COMPOSTED PINE BARK (UP TO 30% BY VOLUME) AND/OR AGRICULTURAL GYPSUM. COARSE SAND MAY BE USED IF ENOUGH IS ADDED TO BRING THE SAND CONTENT TO MORE THAN 60% OF THE TOTAL MIX. SUBSURFACE DRAINAGE LINES MAY NEED TO BE ADDED TO INCREASE DRAINAGE. 1.3.MODIFY EXTREMELY SANDY SOILS (MORE THAN 85%) BY ADDING ORGANIC MATTER AND/OR DRY, SHREDDED CLAY LOAM UP TO 30% OF THE TOTAL MIX. 7. FINISHED GRADING A.UNLESS OTHERWISE CONTRACTED, THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF TOPSOIL AND THE ESTABLISHMENT OF FINE-GRADING WITHIN THE DISTURBANCE AREA OF THE SITE. B.LANDSCAPE CONTRACTOR SHALL VERIFY THAT SUBGRADE FOR INSTALLATION OF TOPSOIL HAS BEEN ESTABLISHED. THE SUBGRADE OF THE SITE MUST MEET THE FINISHED GRADE LESS THE REQUIRED TOPSOIL THICKNESS (1"±). C.ALL LAWN AND PLANTING AREAS SHALL BE GRADED TO A SMOOTH, EVEN AND UNIFORM PLANE WITH NO ABRUPT CHANGE OF SURFACE AS DEPICTED WITHIN THIS SET OF CONSTRUCTION PLANS, UNLESS OTHERWISE DIRECTED BY THE PROJECT ENGINEER OR LANDSCAPE ARCHITECT. D.ALL PLANTING AREAS SHALL BE GRADED AND MAINTAINED TO ALLOW FREE FLOW OF SURFACE WATER IN AND AROUND THE PLANTING BEDS. STANDING WATER SHALL NOT BE PERMITTED IN PLANTING BEDS. 8. TOPSOILING A.CONTRACTOR SHALL PROVIDE A SIX INCH (6") THICK MINIMUM LAYER OF TOPSOIL, OR AS DIRECTED BY THE LOCAL ORDINANCE OR CLIENT, IN ALL PLANTING AREAS. TOPSOIL SHOULD BE SPREAD OVER A PREPARED SURFACE IN A UNIFORM LAYER TO ACHIEVE THE DESIRED COMPACTED THICKNESS. B.ON-SITE TOPSOIL MAY BE USED TO SUPPLEMENT THE TOTAL AMOUNT REQUIRED. TOPSOIL FROM THE SITE MAY BE REJECTED IF IT HAS NOT BEEN PROPERLY REMOVED, STORED AND PROTECTED PRIOR TO CONSTRUCTION. C.CONTRACTOR SHALL FURNISH TO THE APPROVING AGENCY AN ANALYSIS OF BOTH IMPORTED AND ON-SITE TOPSOIL TO BE UTILIZED IN ALL PLANTING AREAS. THE PH AND NUTRIENT LEVELS MAY NEED TO BE ADJUSTED THROUGH SOIL MODIFICATIONS AS NEEDED TO ACHIEVE THE REQUIRED LEVELS AS SPECIFIED IN THE MATERIALS SECTION ABOVE. D.ALL PLANTING AND LAWN AREAS ARE TO BE CULTIVATED TO A DEPTH OF SIX INCHES (6"). ALL DEBRIS EXPOSED FROM EXCAVATION AND CULTIVATION SHALL BE DISPOSED OF IN ACCORDANCE WITH GENERAL WORK PROCEDURES SECTION ABOVE. THE FOLLOWING SHALL BE TILLED INTO THE TOP FOUR INCHES (4") IN TWO DIRECTIONS (QUANTITIES BASED ON A 1,000 SQUARE FOOT AREA): 1.1.20 POUNDS 'GROW POWER' OR APPROVED EQUAL 1.2.20 POUNDS NITRO-FORM (COURSE) 38-0-0 BLUE CHIP E.THE SPREADING OF TOPSOIL SHALL NOT BE CONDUCTED UNDER MUDDY OR FROZEN CONDITIONS. 9. PLANTING A.INSOFAR THAT IT IS FEASIBLE, PLANT MATERIAL SHALL BE PLANTED ON THE DAY OF DELIVERY. IN THE EVENT THAT THIS IS NOT POSSIBLE, LANDSCAPE CONTRACTOR SHALL PROTECT UNINSTALLED PLANT MATERIAL. PLANTS SHALL NOT REMAIN UNPLANTED FOR LONGER THAN A THREE DAY PERIOD AFTER DELIVERY. PLANTS THAT WILL NOT BE PLANTED FOR A PERIOD OF TIME GREATER THAN THREE DAYS SHALL BE HEALED IN WITH TOPSOIL OR MULCH TO HELP PRESERVE ROOT MOISTURE. B.PLANTING OPERATIONS SHALL BE PERFORMED DURING PERIODS WITHIN THE PLANTING SEASON WHEN WEATHER AND SOIL CONDITIONS ARE SUITABLE AND IN ACCORDANCE WITH ACCEPTED LOCAL PRACTICE. PLANTS SHALL NOT BE INSTALLED IN TOPSOIL THAT IS IN A MUDDY OR FROZEN CONDITION. C.ANY INJURED ROOTS OR BRANCHES SHALL BE PRUNED TO MAKE CLEAN-CUT ENDS PRIOR TO PLANTING UTILIZING CLEAN, SHARP TOOLS. ONLY INJURED OR DISEASED BRANCHING SHALL BE REMOVED. D.ALL PLANTING CONTAINERS AND NON-BIODEGRADABLE MATERIALS SHALL BE REMOVED FROM ROOT BALLS DURING PLANTING. NATURAL FIBER BURLAP MUST BE CUT FROM AROUND THE TRUNK OF THE TREE AND FOLDED DOWN AGAINST THE ROOT BALL PRIOR TO BACKFILLING. E.POSITION TREES AND SHRUBS AT THEIR INTENDED LOCATIONS AS PER THE PLANS AND SECURE THE APPROVAL OF THE LANDSCAPE ARCHITECT PRIOR TO EXCAVATING PITS, MAKING NECESSARY ADJUSTMENTS AS DIRECTED. F.PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, THE PROPOSED LANDSCAPE, AS SHOWN ON THE APPROVED LANDSCAPE PLAN, MUST BE INSTALLED, INSPECTED AND APPROVED BY THE APPROVING AGENCY. THE APPROVING AGENCY SHALL TAKE INTO ACCOUNT SEASONAL CONSIDERATIONS IN THIS REGARD AS FOLLOWS. THE PLANTING OF TREES, SHRUBS, VINES OR GROUND COVER SHALL OCCUR ONLY DURING THE FOLLOWING PLANTING SEASONS: 1.1.PLANTS: MARCH 15 TO DECEMBER 15 1.2.LAWN: MARCH 15 TO JUNE 15 OR SEPT. 1 TO DECEMBER 1 G.PLANTINGS REQUIRED FOR A CERTIFICATE OF OCCUPANCY SHALL BE PROVIDED DURING THE NEXT APPROPRIATE SEASON AT THE MUNICIPALITY'S DISCRETION. CONTRACTOR SHOULD CONTACT APPROVING AGENCY FOR POTENTIAL SUBSTITUTIONS. H.FURTHERMORE, THE FOLLOWING TREE VARIETIES ARE UNUSUALLY SUSCEPTIBLE TO WINTER DAMAGE. WITH TRANSPLANT SHOCK AND THE SEASONAL LACK OF NITROGEN AVAILABILITY, THE RISK OF PLANT DEATH IS GREATLY INCREASED. IT IS NOT RECOMMENDED THAT THESE SPECIES BE PLANTED DURING THE FALL PLANTING SEASON: ACER RUBRUM PLATANUS X ACERIFOLIA BETULA VARIETIES POPULOUS VARIETIES CARPINUS VARIETIES PRUNUS VARIETIES CRATAEGUS VARIETIES PYRUS VARIETIES KOELREUTERIA QUERCUS VARIETIES LIQUIDAMBER STYRACIFLUA TILIA TOMENTOSA LIRIODENDRON TULIPIFERA ZELKOVA VARIETIES I.PLANTING PITS SHALL BE DUG WITH LEVEL BOTTOMS, WITH THE WIDTH TWICE THE DIAMETER OF ROOT BALL. THE ROOT BALL SHALL REST ON UNDISTURBED GRADE. EACH PLANT PIT SHALL BE BACKFILLED IN LAYERS WITH THE FOLLOWING PREPARED SOIL MIXED THOROUGHLY: ·1 PART PEAT MOSS ·1 PART COMPOSTED COW MANURE BY VOLUME ·3 PARTS TOPSOIL BY VOLUME ·21 GRAMS 'AGRIFORM' PLANTING TABLETS (OR APPROVED EQUAL) AS FOLLOWS: A) 2 TABLETS PER 1 GALLON PLANT B) 3 TABLETS PER 5 GALLON PLANT C) 4 TABLETS PER 15 GALLON PLANT D) LARGER PLANTS: 2 TABLETS PER ½" CALIPER OF TRUNK J.FILL PREPARED SOIL AROUND BALL OF PLANT HALF-WAY AND INSERT PLANT TABLETS. COMPLETE BACKFILL AND WATER THOROUGHLY. K.ALL PLANTS SHALL BE PLANTED SO THAT THE TOP OF THE ROOT BALL, THE POINT AT WHICH THE ROOT FLARE BEGINS, IS SET AT GROUND LEVEL AND IN THE CENTER OF THE PIT. NO SOIL IS TO BE PLACED DIRECTLY ON TOP OF THE ROOT BALL. L.ALL PROPOSED TREES DIRECTLY ADJACENT TO WALKWAYS OR DRIVEWAYS SHALL BE PRUNED AND MAINTAINED TO A MINIMUM BRANCHING HEIGHT OF 7' FROM GRADE. M.GROUND COVER AREAS SHALL RECEIVE A ¼" LAYER OF HUMUS RAKED INTO THE TOP 1" OF PREPARED SOIL PRIOR TO PLANTING. ALL GROUND COVER AREAS SHALL BE WEEDED AND TREATED WITH A PRE-EMERGENT CHEMICAL AS PER MANUFACTURER'S RECOMMENDATION. N.NO PLANT, EXCEPT GROUND COVERS, GRASSES OR VINES, SHALL BE PLANTED LESS THAN TWO FEET (2') FROM EXISTING STRUCTURES AND SIDEWALKS. O.ALL PLANTING AREAS AND PLANTING PITS SHALL BE MULCHED AS SPECIFIED HEREIN TO FILL THE ENTIRE BED AREA OR SAUCER. NO MULCH IS TO TOUCH THE TRUNK OF THE TREE OR SHRUB. P.ALL PLANTING AREAS SHALL BE WATERED IMMEDIATELY UPON INSTALLATION IN ACCORDANCE WITH THE WATERING SPECIFICATIONS AS LISTED HEREIN. 10. TRANSPLANTING (WHEN REQUIRED) A.ALL TRANSPLANTS SHALL BE DUG WITH INTACT ROOT BALLS CAPABLE OF SUSTAINING THE PLANT. B.IF PLANTS ARE TO BE STOCKPILED BEFORE REPLANTING, THEY SHALL BE HEALED IN WITH MULCH OR SOIL, ADEQUATELY WATERED AND PROTECTED FROM EXTREME HEAT, SUN AND WIND. C.PLANTS SHALL NOT BE DUG FOR TRANSPLANTING BETWEEN APRIL 10 AND JUNE 30. D.UPON REPLANTING, BACKFILL SOIL SHALL BE AMENDED WITH FERTILIZER AND ROOT GROWTH HORMONE. E.TRANSPLANTS SHALL BE GUARANTEED FOR THE LENGTH OF THE GUARANTEE PERIOD SPECIFIED HEREIN. F.IF TRANSPLANTS DIE, SHRUBS AND TREES LESS THAN SIX INCHES (6") DBH SHALL BE REPLACED IN KIND. TREES GREATER THAN SIX INCHES (6") DBH MAY BE REQUIRED TO BE REPLACED IN ACCORDANCE WITH THE MUNICIPALITY'S TREE REPLACEMENT GUIDELINES. 11. WATERING A.NEW PLANTINGS OR LAWN AREAS SHALL BE ADEQUATELY IRRIGATED BEGINNING IMMEDIATELY AFTER PLANTING. WATER SHALL BE APPLIED TO EACH TREE AND SHRUB IN SUCH MANNER AS NOT TO DISTURB BACKFILL AND TO THE EXTENT THAT ALL MATERIALS IN THE PLANTING HOLE ARE THOROUGHLY SATURATED. WATERING SHALL CONTINUE AT LEAST UNTIL PLANTS ARE ESTABLISHED. B.SITE OWNER SHALL PROVIDE WATER IF AVAILABLE ON SITE AT TIME OF PLANTING. IF WATER IS NOT AVAILABLE ON SITE, CONTRACTOR SHALL SUPPLY ALL NECESSARY WATER. THE USE OF WATERING BAGS IS RECOMMENDED FOR ALL NEWLY PLANTED TREES. C.IF AN IRRIGATION SYSTEM HAS BEEN INSTALLED ON THE SITE, IT SHALL BE USED TO WATER PROPOSED PLANT MATERIAL, BUT ANY FAILURE OF THE SYSTEM DOES NOT ELIMINATE THE CONTRACTOR'S RESPONSIBILITY OF MAINTAINING THE DESIRED MOISTURE LEVEL FOR VIGOROUS, HEALTHY GROWTH. 12. GUARANTEE A.THE LANDSCAPE CONTRACTOR SHALL GUARANTEE ALL PLANTS FOR A PERIOD OF ONE (1) YEAR FROM APPROVAL OF LANDSCAPE INSTALLATION BY THE APPROVING AGENCY. CONTRACTOR SHALL SUPPLY THE OWNER WITH A MAINTENANCE BOND FOR TEN PERCENT (10%) OF THE VALUE OF THE LANDSCAPE INSTALLATION WHICH WILL BE RELEASED AT THE CONCLUSION OF THE GUARANTEE PERIOD AND WHEN A FINAL INSPECTION HAS BEEN COMPLETED AND APPROVED BY THE OWNER OR AUTHORIZED REPRESENTATIVE. B.ANY DEAD OR DYING PLANT MATERIAL SHALL BE REPLACED FOR THE LENGTH OF THE GUARANTEE PERIOD. REPLACEMENT OF PLANT MATERIAL SHALL BE CONDUCTED AT THE FIRST SUCCEEDING PLANTING SEASON. ANY DEBRIS SHALL BE DISPOSED OF OFF-SITE, WITHOUT EXCEPTION. C.TREES AND SHRUBS SHALL BE MAINTAINED BY THE CONTRACTOR DURING CONSTRUCTION AND THROUGHOUT THE 90 DAY MAINTENANCE PERIOD AS SPECIFIED HEREIN. CULTIVATION, WEEDING, WATERING AND THE PREVENTATIVE TREATMENTS SHALL BE PERFORMED AS NECESSARY TO KEEP PLANT MATERIAL IN GOOD CONDITION AND FREE OF INSECTS AND DISEASE. D.LAWNS SHALL BE MAINTAINED THROUGH WATERING, FERTILIZING, WEEDING, MOWING, TRIMMING AND OTHER OPERATIONS SUCH AS ROLLING, REGARDING AND REPLANTING AS REQUIRED TO ESTABLISH A SMOOTH, ACCEPTABLE LAWN, FREE OF ERODED OR BARE AREAS. 13. CLEANUP A.UPON THE COMPLETION OF ALL LANDSCAPE INSTALLATION AND BEFORE THE FINAL ACCEPTANCE, THE CONTRACTOR SHALL REMOVE ALL UNUSED MATERIALS, EQUIPMENT AND DEBRIS FROM THE SITE. ALL PAVED AREAS ARE TO BE CLEANED. B.THE SITE SHALL BE CLEANED AND LEFT IN A NEAT AND ACCEPTABLE CONDITION AS APPROVED BY THE OWNER OR AUTHORIZED REPRESENTATIVE. SEEDING SPECIFICATIONS 1.MATERIAL: 1.1.SEED MIXTURE MUST BE COMPRISED OF THE FOLLOWING VARIETIES AND AT THE SPECIFIED COMPOSITION: 1.1.1.80% - TURF TYPE TALL FESCUE SEED 1.1.2.10% - KENTUCKY BLUEGRASS SEED 1.1.3.10% - ANNUAL RYE GRASS SEED 1.2.INSTALLATION RATES: 1.2.1.SEED: LAWN SEED SHOULD BE APPLIED AT A RATE OF 7 LBS/1,000 SF 1.2.2.LIME: AGRICULTURAL OR PELLETIZED LIME SHOULD BE APPLIED AT SPECIFIED RATE ACCORDING TO SOIL ANALYSIS OR 2,000 LBS PER ACRE (46 LBS/1,000 SF) IF NO SOIL ANALYSIS IS PERFORMED. 1.2.3.FERTILIZER: COMMERCIAL GRADE 12-20-12 SHOULD BE APPLIED AT A RATE OF 250 LBS PER PER ACRE (5.8 LBS/ 1,000 SF) 1.2.4.LIQUID OR DRY LIME: LIQUID LIME SHOULD BE APPLIED AT A RATE OF 2.5 GALLONS PER ACRE OR NEUTRA LIME DRY APPLIED AT A RATE OF 80LBS PER ACRE IN AREAS OF ACIDIC SOILS TO ASSURE GERMINATION AND INITIAL ESTABLISHMENT. 1.2.5.MULCH: WHEAT, OAT, OR BARLEY STRAW MULCH SHALL BE APPLIED AT A RATE OF 80 LBS PER 1,000 SF. DO NOT INSTALL MULCH SO THICK THAT IT COMPLETELY COVERS THE GROUND. TOPSOIL SHOULD BE VISIBLE THROUGH THE STRAW LAYER. 2.EXECUTION AND PREPARATION: 2.1.A SOIL ANALYSIS SHOULD BE PERFORMED TO ASSESS THE FERTILITY NEEDS AND PH OF THE SOIL. ALL INSTALLATION AREAS SHOULD BE PREPARED TO AGRICULTURAL STANDARD RECOMMENDED BY THE DEPARTMENT OF AGRICULTURE WITHIN THE STATE WHERE THE WORK IS BEING PERFORMED. AGRICULTURAL LIME OR PELLETIZED LIME SHOULD BE ADDED DURING THE GROUND PREPARATION STAGE AT THE RATE RECOMMENDED ACCORDING TO SOIL ANALYSIS. 2.2.ALL WEEDS AND UNDESIRABLE PLANTS SHOULD BE REMOVED BEFORE PLANTING BY METHOD OF SPRAYING OR TILLAGE. A NON-SELECTIVE HERBICIDE CAN BE SPRAYED ONE MONTH PRIOR TO PLANTING TO KILL ALL WEEDS AND UNDESIRABLE PLANTS THAT MAY COMPETE WITH THE NEW SEEDLINGS. TILLAGE CAN BE PERFORMED AT LEAST 4 WEEKS PRIOR TO PLANTING AND AGAIN 2 WEEKS AFTER THE INITIAL TILLAGE. THE TILLAGE PROCEDURE CAN BE ADVANTAGEOUS IF LARGE AMOUNTS OF ORGANIC DEBRIS ARE PRESENT ON THE INSTALLATION AREAS. 2.3.PRIOR TO SEEDING, AREA IS TO BE TOPSOILED, FINE GRADED, AND RAKED OF ALL DEBRIS LARGER THAN 2" DIAMETER. 2.4.AREAS TO BE PLANTED SHOULD BE ROLLED WITH A CULTI-PACKER, TURF ROLLER, OR SIMILAR DEVICE TO FIRM THE SEEDBED. THIS PROCESS HELPS ACHIEVE THE DESIRED FIRMNESS. SOIL SHOULD BE FIRMED TO 85% OF COMPACTION. 3.INSTALLATION: 3.1.STRICTLY COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS. 3.2.EQUIPMENT USED TO SPREAD SEED SHOULD HAVE SUFFICIENT CAPACITY TO HOLD AND AGITATE SEED EVENLY IN A CYCLONE OR DROP PATTERN. HYDROSEEDING MAY ALSO BE PERFORMED WITH THE ENGINEER/ARCHITECT'S APPROVAL. 3.3.SEED MAY NEED TO BE APPLIED AT A HALF RATE IN ALTERNATING DIRECTIONS TO ENSURE AN EVEN COVERAGE OF SEED. 3.4.LIQUID LIME OR NEUTRA LIME DRY SHOULD BE TOPICALLY APPLIED TO AREAS WITH ACIDIC SOILS TO ASSIST THE SEED GERMINATION AND VEGETATION GROWTH DURING THE FIRST 90 DAYS. LIQUID LIME SHOULD BE APPLIED AT A RATE OF 2.5 GALLONS PER ACRE OR NEUTRA LIME DRY AT A RATE OF 80LBS PER ACRE. 3.5.FERTILIZER SHOULD BE SPREAD EVENLY OVER THE SEEDED AREAS AT THE RECOMMENDED RATE DETERMINED BY THE INITIAL SOIL ANALYSIS. IF NO SOIL ANALYSIS IS AVAILABLE EVENLY APPLY 12-20-12 STARTER FERTILIZER AT A RATE OF 250LBS PER ACRE (5.8LBS/1000 SQUARE FEET). 3.6.A ROLLED EROSION CONTROL PRODUCT CAN BE APPLIED OVER THE TOP OF SEED IN STEEP SLOPE SITUATIONS TO HELP PREVENT SEED FROM WASHING AND REINFORCE VEGETATION THROUGH ESTABLISHMENT. (FOLLOW REC PRODUCT MANUFACTURER RECOMMENDATIONS.) 4.MAINTENANCE 4.1.FREQUENT LIGHT IRRIGATION WILL NEED TO BE APPLIED TO SEEDED AREAS IF NO NATURAL RAIN EVENTS HAVE OCCURRED WITHIN 2 WEEKS OF SEEDING. AFTER SEED GERMINATION HAS OCCURRED AND PLANTS ARE VISIBLE THE FREQUENCY OF IRRIGATION CAN BE CUT BACK WITH HEAVIER APPLICATION RATES. 4.2.REPAIR ALL SEED WASHINGS AND EROSION. OWNER MAINTENANCE RESPONSIBILITIES UPON OWNER'S (OR OWNER CONTRACTOR'S) COMPLETION OF LANDSCAPING WORK, THE OWNER IS FULLY RESPONSIBLE FOR ALL FUTURE MAINTENANCE, CARE, UPKEEP, WATERING, AND TRIMMING OF ALL INSTALLED VEGETATION, PLANTS, TREE, BUSHES, SHRUBS, GRASSES, GRASS, ORNAMENTAL PLANTS AND FLOWERS, FLOWERS, GROUND COVER, AND LANDSCAPING, INCLUDING ALL LANDSCAPE ISLANDS AND AREAS ADJACENT OR PART OF THE LANDSCAPED AREAS. THIS RESPONSIBILITY INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING: ·TREES ADJACENT TO WALKWAYS AND AREAS OF PEDESTRIAN TRAFFIC MUST BE MAINTAINED TO ASSURE THAT ANY BRANCHES MUST BE LIMBED UP TO A CLEARANCE HEIGHT OF 7 FT. (FROM ALL PEDESTRIAN SURFACES) OR PRUNED BACK TO AVOID ANY INTERFERENCE WITH THE TYPICAL PATH OF TRAVEL. ·TREES WITHIN VEHICULAR SIGHT LINES, AS ILLUSTRATED ON THE LANDSCAPE PLAN, ARE TO BE TRIMMED TO A CLEARANCE HEIGHT OF 7 FT. (FROM ALL PAVED, TRAVELED SURFACES), OR AS OTHERWISE INDICATED ON THE PLANS. ·VEGETATIVE GROUND COVER, SHRUBS AND ORNAMENTAL PLANTS AND GRASSES MUST BE TRIMMED SO THAT NO PORTION OF THE PLANT EXCEEDS 30 INCHES ABOVE GRADE (OF ALL PAVED, TRAVEL SURFACES) ALONG AND WITHIN THE SIGHT LINES OF PARKING LOTS AND INGRESS-EGRESS WAYS. ·FALLEN PLANT FLOWERS, FRUIT, SEEDS AND DEBRIS DROPPINGS ARE TO BE REMOVED IMMEDIATELY FROM VEHICULAR AND PEDESTRIAN TRAFFIC AREAS TO PREVENT TRIPPING, SLIPPING OR ANY OTHER HAZARDS. THESE REQUIREMENTS DO NOT AFFECT THE PLANT LIFE GUARANTEES THE LANDSCAPE CONTRACTOR IS REQUIRED TO PROVIDE.