HomeMy WebLinkAbout08-26 Comment ResponsesGibson Property Rezoning
Agency Comment & Response Matrix
Rezoning from RA (Rural Areas) to M1 (Light Industrial) — PINs 87-3-B, 87-A-16B & 87-A-94 — 244.062 acres
Shawnee Magisterial District, Frederick County, Virginia
Frederick County Department of Planning & Development — M. Tyler Klein,
AICP, Senior Planner (June 18, 2026)
# Comment Applicant's Response
I. Comprehensive Plan Conformance
1 The proposed M1 (Light Industrial) district is silent on
potential or restricted uses and on how the proposal would
further County policy, the Economic Development
Authority’s targeted industries, or the area plan’s envisioned
“mix of flexible uses” and “mixed-use industrial office”
(MUIO) designation along Route 277. At a minimum, uses
that might be noxious, unsafe, or disruptive, and uses
generating higher traffic than contemplated in the TIA,
should be considered for exclusion.
Applicant has revised the
proffers to delete M1 by right
uses of regional criminal
justice, enforcement, and
detention facilities, and
freestanding fast food and/or
any restaurant that includes a
drive-through window/food
service. The TIA submitted by
Applicant’s traffic engineer has
contemplated uses as directed
by and agreed with the
County’s traffic agency, VDOT.
Accordingly, it is submitted that
the TIA does accurately
address traffic impact being
generated by this M1 site.
2 Plan policy elements such as “high quality architecture and
site design” are absent or under-developed. EIFS specified
as a primary building material in Proffer 1.2 is not typically
considered high quality, and no building renderings,
elevations, or conceptual layouts are provided to evaluate
architecture and site layout. Plan conformance is only
partially achieved.
Acknowledged and will be
considered during site plan
process once rezoned.
3 Sensitivity should be given to how a future large industrial
assembly may impact adjacent sub-planning areas and the
rural areas of Clarke County. The Lake Frederick Urban
Development Area (Lake Frederick and Madison Farms) is
immediately to the south. Enhanced buffering and
screening, lower building heights, and increased building
setbacks may be appropriate mitigation for noise, odor,
vibration, and traffic impacts.
Acknowledged and will be
considered during site plan
process once rezoned.
4 PIN 87-3-A has no future land use designation and is
outside the SWSA; it is planned to remain “rural.” A
concurrent CPPA request for this parcel did not receive
consensus for further study.
The referenced property has
been removed from the
rezoning application.
II. Transportation & Traffic Analysis
5 The Plan identifies planned transportation improvements on
the property, including a new major collector road and
multiuse trail connecting Route 277 to Route 522, multiuse
trails along Route 522 and Route 277, and future widening
of Route 277. While the collector road right-of-way is
proffered, the other planned improvements are missing from
the application materials, including the GDP and proffer
statement.
Applicant has proffered
sufficient right-of-way for the
dedication of a contemplated
future major collector road.
The right-of-way is proffered to
specifications which are similar
to the Madison Farms rezoning
for the same potential future
major collection road. The
right-of-way is of sufficient
width for 6 lanes along Route
522, 5’ sidewalk along Route
277, and a 10’ trail on west
side of Route 522.
6 The Traffic Impact Study (May 8, 2026) notes that key
regional intersections (#1 and #3) continue to fail and,
because no transportation improvements are planned, none
are proposed as a result of the Gibson development. This is
grossly inadequate given long-standing County policy that
developments fully mitigate impacts to adjoining
transportation infrastructure. Special attention should be
paid to improvements warranted at Route 522 and Fairfax
Pike/Lord Fairfax Highway (Intersection #3).
Improvements to Intersections
#1 and #3 are necessitated by
existing and background
conditions traffic. The TIA has
been updated to identify the
improvements needed to offset
the site’s impact. Specifically,
at Fairfax Pike/Warrior Drive
(Int. #1), left turn phasing
improvements have been
identified in the updated TIA to
offset the site’s impact to
background conditions. At
Fairfax Pike/Route 522 (Int.
#3), an exclusive EB left turn
lane and a 2nd NB left turn lane
have been identified as
improvements that will offset
the site’s impact to background
conditions.
7 A Signal Justification Report (SJR) — noted in the TIS for
Route 522 (Site Entrances #4 and #5) and the western site
entrance on Fairfax Pike/Route 277 (Site Entrance #1) —
should be completed during the preliminary comment period
and reviewed and approved by VDOT prior to acceptance of
the application for public hearings. The approved Madison
277 proffer (REZ #07-25) also contemplates an SJR and
potential signal on Route 277; the applicant should
coordinate with the Madison 277 owner (Dave Madison) on
sharing the cost and installation of a potential signal and on
the timing/trigger of that improvement.
The Applicant has met with
and been coordinating closely
with VDOT about the SJR
process and timeline for this
project since receiving
comments. VDOT has
concurred that the full SJR
review and approval can be
deferred to site plan review
and approval, given the TIS is
updated to include VJuST
analysis of alternative/
innovative intersection
configurations at the new
proposed signalized entrance
locations, Int # 6 and Int #9
(VJuST analysis). The revised
TIS submission includes this
additional analysis and
includes a range of
intersection configurations for
recommendation, subject to a
final future SJR review and
approval during site plan.
It should be clarified that the
proposed western entrance on
Rt 277 is proposed as aligned
with the planned Lake
Frederick entrance and no
entrance is proposed across
from the planned Madison
Farm entrance.
III. Proffer Statement
8 Provide an “Original Date of Proffers.” Acknowledged.
9 The proffer statement does not contemplate allowed or
prohibited uses, the potential impacts to adjoining properties
and roadways, or mitigation measures.
Applicant has removed
allowable uses of regional
criminal justice, enforcement,
and detention facilities, and
freestanding fast food and/or
any restaurant that includes a
drive-through window/food
service from the Property. This
is consistent with what has
been recently proffered for
another approved zoning to
M1 in Frederick County.
10 Proffer 2 does not fully address level of service (LOS)
failures, traffic impacts, and the planned transportation
improvements outlined in the Comprehensive Plan for
adjoining roadways. Specifically, the TIS notes turn lanes for
points of access to and from Route 522 that are not
expressly listed in the proffer statement.
See the responses to
Comments #6 and 7 above.
IV. Other Application Materials & Fee
11 Based on the fees adopted by the Board of Supervisors, the
application fee for this application would be $32,207.
Acknowledged.
V. Agency Comments
12 Agency comments are attached. Once the application is
complete and the fee is paid, it will also need to go to the
Historic Resources Advisory Board (HRAB) prior to
scheduling for public hearing.
Consistent with an email dated
July 2, 2026, the County
confirmed it has received all
required agency comments to
allow this rezoning to proceed
to public hearing. The
Applicant appeared before
HRAB on August 21, 2026 and
acknowledges the comments
made during the meeting.
Further, this application is on a
strict timetable in order to be
compliant with the
requirements for the VEDP
grant which requires all grant-
eligible property to be fully
zoned (M1 industrial). As such,
Applicant respectfully requests
this matter be heard by the
Frederick County Planning
Commission at its hearing on
September 2nd and the Board
of Supervisors at its hearing on
September 23rd.
Frederick Water — Eric R. Lawrence, Executive Director (June 12, 2026)
# Comment Applicant's Response
I. Service Area & Availability
1 Parcels 87-3-B and 87-A-16B are located within the Sewer
and Water Service Area (SWSA), so by county policy water
and sewer services are available to access. A 12-inch water
main parallels the south side of Route 277. A sanitary sewer
force main was recently constructed on and near the project
parcels, but it was not sized to accommodate development
of the subject properties and may not have capacity to
support this development. A parallel force main was
designed but not constructed because projected sewer
demands did not warrant the additional capacity.
Sanitary sewer computations
and a force main design will be
completed as required to
design a facility that can
accommodate the proposed
development. Preliminary
exhibits showing a plan of
approach have been circulated
to Frederick Water.
Further, and as stated above,
this property is the subject of
an active VEDP grant which, if
awarded, will provide funds for
infrastructure improvements
related to this property. Said
infrastructure includes, but is
not limited to, public water and
sewer improvements. If
Frederick Water is noting that
its existing facilities may
require some upgrades, the
VEDP grant award would be
most timely and be put to good
use to make those required
improvements.
2 Parcel 87-3-A is not currently within the SWSA and by
county policy may not access public water and sewer. Public
water and sewer facilities are not in the vicinity of parcel 87-
3-A.
The referenced property has
been removed from the
rezoning application.
II. Impact Analysis Statement
3 The Impact Analysis Statement dated May 27, 2026 is silent
on proposed water and sewer demands and on applicant
responsibilities. The applicant should provide proposed
water and sewer demands and clarify the statement
regarding “the effort required by the County” for sanitary
sewer.
Applicant has attached a
report prepared by Bohler,
which addresses anticipated
water and sewer demands for
this property. It should be
noted these are anticipatory
reports based on assumed
buildout and uses. The actual
consumption of water and
sewer will undoubtedly change
and will certainly be adjusted
as actual users become known
and the industrial property is
developed.
III. Applicant Responsibilities
4 The applicant must ensure adequate water and sanitary
sewer conveyance and treatment system capacity is
available to achieve the projected build-out of the project. It
is the applicant’s responsibility to fund the design, easement
acquisition, and construction of the extensions of water and
sewer services necessary to satisfy the proposed demands.
The Applicant will complete
sanitary and water studies and
designs to demonstrate
adequate water and sanitary
sewer conveyance and
treatment system capacity for
the proposed development.
5 Sanitary sewer force mains warrant scrutiny during design;
an oversized force main with inadequate flows can result in
septic conditions, sludge buildup, reduced flow capacity,
internal corrosion, cycling fatigue, and odors. The applicant
must address its sanitary sewer requirements and solutions
once its flow generation is more clearly known. If the
appropriate sewer solution benefits a regional service rather
than solely the applicant’s properties, a partnership with
other benefiting property owners and Frederick Water
should be considered.
Sanitary sewer computations
and a force main design will be
completed as required to
design a facility that can
accommodate the proposed
development. Preliminary
exhibits showing a plan of
approach have been circulated
to Frederick Water.
IV. Standards & General
6 Water and sanitary sewer improvements are to be
constructed in accordance with Frederick Water standards
and specifications, and easements will be required for
infrastructure dedicated to Frederick Water. These
comments are offered without the benefit of the proposed
water and sewer demands, and the letter does not
guarantee system distribution, collection, or treatment
capacity for the development.
Water and sewer
improvements will be proposed
and constructed in accordance
with Frederick Water
standards and specifications,
and easements will be
proposed per Frederick Water
requirements.
Virginia Department of Transportation — VDOT Staunton District (June 10,
2026)
# Comment Applicant's Response
TIA Review Comments (1st Submission, TIA dated May 8, 2026)
1 The TIA conclusion indicates that the reported LOS and
queuing deficiencies at the study intersections are due to
existing or background traffic volumes and not the proposed
site traffic. Regardless of the responsible party, the intent of
the TIA is to provide future traffic conditions and the
improvements necessary to mitigate unacceptable
conditions. The initial submission does not meet that intent
and is therefore incomplete. Revise the analysis and report
to present future scenarios that mitigate the reported traffic
conditions with the development.
Improvements to Intersections
#1 and #3 are necessitated by
existing and background
conditions traffic. The TIA has
been updated to identify the
improvements needed to offset
the site’s impact. Specifically,
at Fairfax Pike/Warrior Drive
(Int. #1), left turn phasing
improvements have been
identified in the updated TIA to
offset the site’s impact to
background conditions. At
Fairfax Pike/Route 522 (Int.
#3), an exclusive EB left turn
lane and a 2nd NB left turn lane
have been identified as
improvements that will offset
the site’s impact to background
conditions.
2 The TIA indicates overcapacity conditions in all future-year
scenarios. Per TOSAM, overcapacity conditions require
microsimulation to evaluate operations and report MOEs.
However, if the new mitigated future scenarios (requested
above) are no longer overcapacity, the currently reported
future unmitigated MOEs will be acceptable.
As discussed with VDOT at the
7/13/26 meeting, with the
added improvements proposed
at Int. #1 and Int. #3, majority
of the movements are not
overcapacity, and
microsimulation is not
required.
3 The approved pre-scoping document indicated the
westernmost site entrance on Route 277 would align as the
4th leg of the planned Madison Farm development entrance
(recommended for signalization). The TIA instead shifted
this entrance east to align with the future Lake Frederick
entrance on Route 277, with a signal recommendation. This
would add two future signals on the Route 277 corridor,
which is not desirable on a Minor Arterial connecting I-81 to
US 340/522 even if minimum spacing is met. What resulted
in the change of the proposed entrance location?
The proposed Madison Farms
and Lake Frederick entrances
on Route 277 presented two
potential access locations for
the Gibson site’s western
parcel. Although the concept
plan during scoping initially
contemplated alignment with
Madison Farm’s entrance, it
was subsequently determined
that aligning the entrance with
Lake Frederick would be
preferable, as that
development and entrance is
further along and the proposed
potential signal would provide
greater benefit to the wider
community including Lake
Frederick residents. As noted
in the comment, entrance
spacing standards would be
met.
4 The current analysis does not support the recommended
future signals at study intersection 6 (site entrance 1) and
study intersection 9 (site entrances 4/5). An SJR must be
submitted and approved at both locations for VDOT
acceptance of the TIA with these recommendations. Both
recommended signal locations should also consider signal
coordination in the future build year (including modeling the
proposed Madison Farms signal on Route 277 if the
entrance cannot be adjusted per the comment above).
Per the meetings with VDOT
on 7/13/26 and 7/23/26, full
SJR review and approval can
be deferred to site plan review
and approval, given the TIS is
updated to include VJuST
analysis of alternative/
innovative intersection
configurations at the proposed
signalized entrance locations,
Int # 6 and Int #9 (VJuST
analysis). The revised TIS
submission includes this
additional analysis and
includes a range of
intersection configurations for
recommendation, subject to a
final future SJR review and
approval during site plan.
As requested, under mitigated
signalization scenarios, the
proposed signal on Rt 277 is
shown as coordinated with
Madison Farm’s signal in
Synchro and the proposed
signal on Rt 522 is shown as
coordinated with the Rt 522/Rt
277 signal in Synchro.
5 Per the pre-scoping document, while the signalized
intersection of US 522 and Maranto Manor Drive is not a
study intersection, the signal was to be included in the
Synchro modeling as an Affected Traffic Signal. Because
US 522 is on the VDOT Arterial Preservation Network, this
signal should be included in the modeling alongside the
proposed new signal at site entrance #4 (study intersection
#9) to ensure proper evaluation. Signal coordination seems
likely and may extend north to the signal at Tasker Road.
The Maranto Manor Drive
signal was not previously
included in the Synchro model
as it was confirmed with VDOT
that it is currently
uncoordinated. However, as
discussed with VDOT on
subsequent calls, it has been
added to the existing and
future year Synchro networks
in the resubmission for
thoroughness. The signal is
currently uncoordinated but
has been changed to
coordinated between Maranto
Manor Drive and Tasker Drive
for all future year analysis.
6 HCM 2000 outputs are reported for the signal at US
522/340/Route 277 instead of HCM 6 due to non-NEMA
phasing. Only the phase assignment in the timing plan is
non-compliant; adjust it from Phase 3 to Phase 8 to make
The Intersection #3 phasing
has been updated accordingly
to allow HCM 6 to produce
results. It is noted that HCM 6
the intersection NEMA compliant, then update the results to
HCM 6 throughout the report per TOSAM requirements.
requires manual input for
RTOR reductions. The RTOR
reduction was determined
based on HCM 2000’s
methodology and has been
updated for all signalized study
intersections. This is noted as
most intersections now show
slightly improved results.
7 Update the Executive Summary and Conclusion sections to
indicate the reported delay in seconds associated with each
level of service, to better communicate the impacts on the
listed study intersections, approaches, or movements.
As discussed with VDOT,
delay in seconds has been
added to all LOS F
descriptions in the Executive
Summary and Conclusions.
Frederick County Fire Marshal — Adam Hounshell, Lieutenant/Assistant Fire
Marshal (June 16, 2026 — Status: Approved)
# Comment Applicant's Response
1 All future development shall comply with the Frederick
County Fire Prevention Code and all other applicable codes.
Acknowledged, future
development will comply with
Frederick County Fire
Prevention Code and other
applicable codes.
Frederick County Public Works — J. Wilder (jwilder@fcva.us)
# Comment Applicant's Response
1 A comprehensive review shall occur at the time of site plan
submission. No additional comments are offered at this time.
Acknowledged.
Clarke County Department of Planning — Brandon Stidham, Planning Director
(June 12, 2026)
# Comment Applicant's Response
1 No comments at this time. Staff reserves the opportunity to
comment on possible transportation impacts after reviewing
VDOT’s comments on this application. VDOT staff has
offered to involve Clarke County in their review process.
Acknowledged.
Virginia Department of Transportation — VDOT Staunton District (August 7,
2026)
# Comment Applicant's Response
TIA Review Comments (2nd Submission, TIA dated July 30, 2026)
1 Western Parcel Entrance Alignment Requirement – During
site plan development, VDOT will expect the proposed
entrance serving the western portion of the Gibson Property
to be aligned with the Madison Farm entrance located
directly opposite on Route 277. This corridor already faces
spacing constraints, and aligning these entrances is
essential to limiting the number of future major intersections
or traffic signals and preserving safe, efficient traffic
operations. The applicant has not demonstrated that an
entrance cannot be accommodated at this location.
Accordingly, VDOT will consider this alignment necessary
during the site plan development and review process.
Comment acknowledged. It is
noted on the Rezoning Plan
that entrance locations shown
are approximate and to be
determined at time of final site
plan design. Locations to be in
accordance with VDOT
spacing requirements. Access
points may be added or
eliminated subject to VDOT
approval at time of site plan.
2 Right-of-Way Dedication Along Route 277 - VDOT
recommends that the applicant dedicate sufficient right-of-
way along the project frontage to accommodate the ultimate
U4D roadway section for Route 277, as identified in the
Frederick County Comprehensive Plan. Securing this right-
of-way at the rezoning stage is essential to support long-
term corridor improvements.
Right-of-way dedication along
Route 277 has been included
in the proffers.
3 Lack of Transportation Mitigations in Proffer Statement -
Based on the proffer statement submitted to VDOT with the
application, no transportation improvements or mitigations
are being offered by the applicant. The TIS demonstrates
significant delays at the intersection of Route 277 and Route
522/340, particularly during peak hours. Under future 2035
background conditions (without the project), the intersection
is projected to operate at LOS F/F, with overall intersection
delay at 109 seconds in the AM and 161 seconds in the PM.
With the development in 2035, intersection overall
intersection delay increases to 147 seconds in the AM and
190 seconds in the PM. The TIS provides a mitigated
scenario that includes an exclusive eastbound left turn lane
and a second northbound left turn lane that improves overall
intersection delay to 53 seconds in the AM (LOS D) and 94
seconds in the PM. Given these findings, VDOT cannot
support the rezoning application without transportation
mitigations that address the documented operational
deficiencies.
Transportation mitigations at
the intersection of Route 277
and Route 522/340 have been
included in the proffers,
subject to sufficient right-of-
way.
4 Entrance Locations, Signalization, and Future Studies – All
entrance locations, spacing, and configurations will be
determined during the final site plan review process. No
Signal Justification Reports (SJRs) have been provided with
this rezoning application. The signal warrant analyses
included in the TIS are preliminary and do not constitute an
approved SJR. VDOT reserves the right to eliminate,
relocate, or modify any entrance shown on the Generalized
Comment acknowledged. The
commitment to perform and
submit SJRs during site plan
has been included in the
proffers.
Development Plan (GDP) based on final engineering review,
spacing requirements, and corridor operations.