HomeMy WebLinkAbout07-20 Signed First Page1 2 3 0 5 L 0 10 L K H G F E C STANDARD PROJECT LEGEND: COMM PROPOSED COMMUNICATIONS LINE ELEC OH PROPOSED OVERHEAD POWER ELEC UG PROPOSED UNDERGROUND POWER FO PROPOSED FIBER OPTIC LINE GAS PROPOSED GAS LINE -GEOTHERMAL- PROPOSED GEOTHERMAL LINE SS PROPOSED SEWER LINE SS FM PROPOSED FORCE MAIN STEAM PROPOSED STEAM LINE TELE OH PROPOSED OVERHEAD TELEPHONE TELE UG PROPOSED UNDERGROUND TELEPHONE W PROPOSED WATER LINE = -EXISTING STORM SEWER PROPOSED STORM SEWER - $ - EXISTING WATER GATE VALVE �-- PROPOSED WATER GATE VALVE AR AIR RELEASE VALVE -C EXISTING FIRE HYDRANT PROPOSED FIRE HYDRANT ® WATER METER TEE + WATER MAIN CROSS ► WATER MAIN REDUCER -� WATER MAIN PLUG O' EXISTING SANITARY MANHOLE PROPOSED SANITARY MANHOLE • SANITARY SEWER CLEANOUT COMM--m COMMUNICATION PULLBOX COMM-9 COMMUNICATIONS MANHOLE/HANDHOLE ELEC--@) ELECTRICAL POWER MANHOLE/HANDHOLE -0 SITE LIGHTING -f- UTILITY POLE 0 POST - -1400- - EXISTING CONTOURS 1400 PROPOSED CONTOURS EXISTING CURB & GUTTER PROPOSED CURB & GUTTER REVERSE CURB & GUTTER REVERSE CURB & GUTTER TRANSITION EXISTING FENCE/GUARDRAIL PROPOSED FENCE/GUARDRAIL y SIGN STEAM LINE GRATE ® BENCHMARK NOTE: 1. ANY SYMBOL NOT CALLED OUT IN LEGEND WILL BE LABELED ON PLAN. 2. NOT ALL SYMBOLS IN LEGEND APPLY TO THIS PLAN. 3. AN W' IN FRONT OF ANY UTILITY LINE TYPE INDICATES EXISTING. 4. NUMBERS ON A UTILITY LINE INDICATES LINE SIZE. RESPONSIBLE LAND DISTURBER: A NAME: CERT #: EXPIRATION: FREDERICK COUNTY, VIRGINIA B/W BOTTOM OF WALL BFF BASEMENT FINISH FLOOR BM BENCHMARK C-C CENTER TO CENTER CG CURB & GUTTER CL CENTER LINE CMP CORRUGATED METAL PIPE CO CLEAN OUT CONC CONCRETE DI DUCTILE IRON PIPE A DELTA ESMT EASEMENT EP EDGE OF PAVEMENT ELEV ELEVATION EW ENDWALL EX EXISTING FCR FOOT CANDLE RADIUS FDC FIRE DEPARTMENT CONNECTION FES FLARED END SECTION FF FINISH FLOOR FH FIRE HYDRANT FM FORCE MAIN H HEIGHT HDPE HIGH -DENSITY POLYETHYLENE INV INVERT L LENGTH LF LINEAR FEET MH MANHOLE NTS NOT TO SCALE N/F NOW OR FORMERLY O-C ON CENTER PC POINT OF CURVATURE PCC POINT OF COMPOUND CURVATURE PI POINT OF INTERSECTION PL PROPERTY LINE PRC POINT OF REVERSE CURVE PROP PROPOSED PT POINT OF TANGENCY PVC POINT OF VERTICAL CURVATURE PVI POINT OF VERTICAL INTERSECTION PVMT PAVEMENT PVT POINT OF VERTICAL TANGENT R RADIUS R/W RIGHT-OF-WAY RCP REINFORCED CONCRETE PIPE RD ROOF DRAIN ROW RIGHT-OF-WAY S/S SPOT SHOT SCH SCHEDULE SEW SANITARY SEWER SS SANITARY SEWER STA STATION STD STANDARD STR STRUCTURE SWM STORMWATER MANAGEMENT TBM TEMPORARY BENCH MARK TYP TYPICAL T/C TOP OF CURB T/G TOP OF GRADE / SIDEWALK T/P TOP OF PAVEMENT T/W TOP OF WALL WM WATER MAIN W/ WITH I Aft aftm w �a CA lE CALL MISS UTILITY PRIOR TO EXCAVATION 811 OR 1.800.552.7001 SUBCONTRACTORS MAY NOT WORK UNDER ANOTHER COMPANY'S TICKET UNLESS THEY ARE UNDER THE DIRECT SUPERVISION OF THE COMPANY THAT PROVIDED THE NOTICE OF EXCAVATION. ALLOW REQUIRED TIME FOR MARKING AND BEGIN EXCAVATION ONLY AFTER CHECKING THE POSITIVE RESPONSE SYSTEM. EXCAVATION MAY BEGIN WHEN: ALL NOTIFIED UTILITIES HAVE EITHER MARKED THEIR LINES OR REPORTED THAT THEY HAVE NO FACILITIES IN THE AREA OF EXCAVATION OR THE MARKING PERIOD HAS EXPIRED (AFTER 7:00 AM ON THE THIRD WORKING DAY AFTER NOTICE TO THE CENTER.) OR MISS UTILITY INFORMS YOU THAT NO MEMBER OPERATORS NEED TO BE NOTIFIED OF THE EXCAVATION. YOU WILL STILL GET A TICKET NUMBER! RESPECT THE MARKS - PROTECT AND PRESERVE THE MARKINGS FROM THE TIME EXCAVATION BEGINS UNTIL THE WORK IS COMPLETED. CALL MISS UTILITY TO UPDATE THE TICKET IF WORK WILL CONTINUE PAST 15 DAYS OR IF THE MARKS BECOME ILLEGIBLE DUE TO TIME, WEATHER, CONSTRUCTION OR ANY OTHER CAUSE, EXCAVATE CAREFULLY - IF THE EXCAVATION IS WITHIN 2 FEET OF A MARKED UTILI rY LINE, EXPOSE THE UTILITY LINE BY HAND DIGGING AND KEEP ALL MECHANIZED EQUIPMENT AT LEAST 2 FEET AWAY FROM THE EXTREMITIES OF THE UTILITY. VICINITY MAP 1 " = 2000' VALLEY ENGINEERING, PLC CONTACT: CARL L. SNYDER JR., P.E. 4901 CROWE DRIVE MOUNT CRAWFORD, VIRGINIA 22841 TELEPHONE (540) 434-6365 OR (800) 343-6365 FAX (540) 432-0685 www.valleyesp.com OWNER/DEVELOPER: VALLEY HEALTH CONTACT: MARK BAKER 1836 AMHERST ST. WINCHESTER, VIRGINIA 22601 TELEPHONE (540) 536-4543 PROJECT DIRECTORY FREDERICK COUNTY PLANNING & DEVELOPMENT 107 NORTH KENT ST. SUITE 202 WINCHESTER, VA 22601 (540) 665-5651 FREDERICK COUNTY PUBLIC WORKS 107 NORTH KENT ST. SUITE 200 WINCHESTER, VA 22601 (540) 665-5643 FREDERICK COUNTY INSPECTIONS 107 NORTH KENT ST. WINCHESTER, VA 22601 (540) 665-5650 FREDERICK WATER 315 TASKER ROAD STEPHENS CITY, VA 22655 (540) 868-1061 CITY OF WINCHESTER ENGINEERING ROUSS CITY HALL 15 NORTH CAMERON ST. WINCHESTER, VA 22601 (540) 667-1815 FREDERICK COUNTY FIRE & RESCUE 1080 COVERSTONE DRIVE WINCHESTER, VA 22602 (540) 665-6350 VIRGINIA DEPARTMENT OF TRANSPORTATION EDINBURG RESIDENCY 14031 OLD VALLEY PIKE EDINBURG, VA 22824 (540) 984-5608 VIRGINIA DEPARTMENT OF HEALTH -DRINKING WATER 107 NORTH KENT ST. WINCHESTER, VA 22601 (540) 665-5600 VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY 4411 EARLY RD. HARRISONBURG, VA 22801 (540) 574-7800 SHENANDOAH VALLEY ELECTRIC COOPERATIVE SITE PLAN APPROVAL NAME ... K .....DA11$ -4oIA SITE PLAN NUMBED () -4 - Zb APPROVED BY THE FREDERICK COUNTY ZONING ADMINISTRATOR THIS SITE PLAN IS VALID FOR (5) FIVE Y S FROM APPRO AL DATE ZONING ADMINISTRATOR WINCHESTER, VA 22601 (540) 450-0111 Sheet List Table SHEET NUMBER SHEET TITLE C0.01 TITLE SHEET C1.01 GENERAL NOTES C1.02 GEOTECHNICAL REPORT C1.03 GEOTECHNICAL REPORT C1.04 GEOTECHNICAL REPORT C1.05 GEOTECHNICAL REPORT C1.06 GEOTECHNICAL REPORT C1.07 GEOTECHNICAL REPORT C1.08 APPROVED MASTER DEVELOPMENT PLAN C2.01 EXISTING CONDITIONS & DEMOLITION PLAN C2.02 EXISTING CONDITIONS C3.01 EROSION & SEDIMENT CONTROL NOTES C3.02 EROSION & SEDIMENT CONTROL PLAN C3.03 EROSION & SEDIMENT CONTROL DETAILS C4.01 OPEN SPACE PLAN C4.02 OVERALL SITE PLAN C4.03 DETAILED SITE PLAN C4.04 DETAILED SITE PLAN C4.05 CODE REQUIRED LANDSCAPE PLAN C4.06 FIRE LANE STRIPING & SIGNAGE PLAN C5.01 SOUTH ENTRANCE PROFILE & SIGHT DISTANCE C5.02 MID ENTRANCE PROFILE & SIGHT DISTANCE C5.03 NORTH ENTRANCE PROFILE & SIGHT DISTANCE C5.04 SEWER PLAN & PROFILE C5.05 STORM PLAN & PROFILE C5.06 STORM PLAN & PROFILE C5.07 STORM PLAN & PROFILE C5.08 WATER PLAN & PROFILE C6.01 OVERALL GRADING PLAN C6.02 DETAILED GRADING PLAN C6.03 DETAILED GRADING PLAN C6.04 CUT -FILL MAP C6.05 INLET DRAINAGE AREA MAP C6.06 POST LAND COVER MAP C7.01 VDOT DETAILS C7.02 FREDERICK WATER DETAILS C7.03 SITE DETAILS E1.1 LIGHTING PLAN WINCHESTER MEDICAL CENTER WEST CAMPUS CAB FREDERICK COUNTY, VA C� z Q W L0 (0 8'3 N LL Ct z � (D 9 W WMr W ((� z cr Q w W N o oZ WW z Qo W z_R W r J cl) OLOO �•� � W E [L O /n v W �M)OO UO WE z p _ 5; W �� � o(� Q N 9z W � 6:2 UOm4 �i a � z0 w �ULO �Z. W o I- LLI Z� W Z � O ,Z Of o� J W =O r J _' W E F- � o �RL L 3NYDEN, JR `i;- Lic. No. 042587-1 O,��s 08/20/2021 �1,� StONAL S# PREVIOUS APPROVALS: REZ #02-03 MDP #06-04 REZ #06-19 MDP #05-21 CURRENT: SP #07-20 REVISIONS: 04/13/20 - PRICING SET 06/22/21 -COUNTY REVIEW COMME 07/28/21 -COUNTY REVIEW COMME 08/20/21 - GIS REVIEW COMMENTS DATE: 02/12/2020 PROJECT No.: 11995-3 EXP./CLIENT No.: 7767-2 SCALE: AS SHOWN TITLE SHEET SHEET NO.: C0,01 1 2 3 1 4 �l 7 10