HomeMy WebLinkAbout11-24 PC Staff Report - JanuaryREZONING #11 -24 Route 7 Self Storage (Edward P. Browning IV) Staff Report for the Planning Commission Prepared: December 31, 2024 Staff Contact: Kayla Peloquin, AICP, Planner Executive Summary: Meeting Schedule Planning Commission: January 15, 2025 Action: Pending Board of Supervisors: February 12, 2025 Action: Pending Property Information Property Identification Number (PIN) 55-A-180 Address Berryville Pike (Route 7) Magisterial District Red Bud Acreage +/- 2.38 acres Zoning & Present Land Use Zoning: B1 (Neighborhood Business) Land Use: Vacant Proposed Zoning B2 (General Business) Adjoining Property Zoning & Present Land Use North: Principal Arterial Land Use: Berryville Pike (Route 7) South: RP (Residential Performance) District Land Use: Single Family Residential East: RA (Rural Areas) District Land Use: Restaurant/Pub West: RA (Rural Areas) District Land Use: Single Family Residential Proposed Use This is a request to rezone one (1) parcel of 2.38-acres from the B1 (Neighborhood Business) Zoning District to the B2 (General Business) Zoning District with proffers to allow for a self storage facility. Positives Concerns The proffer statement prohibits hotel and/or motel uses, fast food restaurants, and gas stations, which generate significantly more trips than self-storage. Additional business development in the County could provide employment opportunities and tax revenue to the County. Although several uses have been restricted, many B2 permitted remain including, but not limited to, car washes, retail trade, and personal care services that have the potential to generate more trips than the stated desired use of self-storage. 513 Page 2 of 4 The proposed rezoning is not in conformance with the Comprehensive Plan, which designates the desired long-range land use as residential. The GDP shows 3 trailer parking spaces, which may be able to accommodate RVs, campers, and other types of trailers. Given the direct access off Route 7 and the speed limit (45 MPH), this is not an ideal location for trailer parking. The transportation proffers do not address the eastbound right turn lane VDOT stated the developer should commit to building to access the proposed development. Review Agency Comments: Review Agency Comment Date Comment Summary Status Frederick County (FC) Fire Marshal December 13, 2023 Fire apparatus access roads must be shown on the site plan. Applicant acknowledged fire access roads must be shown on site plan. FC Attorney January 25, 2024 Proffer statement is “legally sufficient” subject to several comments. No method has been identified for determining when traffic generated would exceed 120 trips per day to trigger the requirement for an updated TIA. Partially addressed. The transportation proffer language is not abundantly clear. Frederick Water January 2, 2024 The submission included a preliminary site plan and entrance concept along Route 7, which will be atop an existing 10-inch water main, will require that the developer replace the water main as construction atop the main will certainly cause damage to the main. We look to the design phase of the project to review the detailed entrance improvements and water main replacement plans. Applicant has acknowledged the comment. 514 Page 3 of 4 FC Public Works December 19, 2023 No comment. VDOT December 19, 2024 Given the location of this property on a narrow section of Route 7 (without adequate shoulders), we would suggest a commitment by the developer to provide a full right turn lane into the project (100-feet storage, 100-feet taper). Not addressed. The proffers and the GDP do not specifically address the right turn lane. Planning & Zoning Staff Analysis: Site History: The property was part of a large rezoning from A2 (Agricultural General) to RP (Residential Performance) in 1987 and was later subdivided and rezoned from RP to B1 (Neighborhood Business) in 1989 with no proffers. General Development Plan (GDP), Site Access, and Transportation: The GDP depicts a new entrance south off Route 7 with a proposed bridge over a stream (Ash Hollow Run) that runs largely parallel to Route 7. The GDP shows 8 vehicle parking spaces along with 3 “trailer parking” spaces. There are existing entrances nearby, approximately 60’ west of the western property boundary and approximately 20’ east of the eastern property boundary. The posted speed limit is 45 MPH. The right turn lane requested by VDOT (100’ storage and 100’ taper) is not shown on the GDP. The impact analysis states, “the business assumes five employees and possibly five customers daily” (pg. 2) and later states “the estimated vehicle trips per weekday average is 58.6 trips per day (TPD) per the ITE Trip Generation Manual, 7th edition” (pg. 2). The impact analysis does not specify what proposed use was used to generate a weekday average of 58.6 TPD and does not acknowledge the other potential B2 uses that have not been proffered out. Comprehensive Plan Conformance: The Comprehensive Plan and the Senseny/Eastern Frederick Area Plan provide guidance on the future development of the subject property. The Plan identifies this property with a “residential” land use designation of 4 dwelling units per acre (4 u/a) and is within the limits of the Sewer and Water Service Area (SWSA) and the Urban Development Area (UDA). The Plan envisions this area of the County and the Route 7 corridor to remain residential. Business uses are planned closer to Interstate 81 and west of Greenwood Road. Therefore, the current and proposed zoning is inconsistent with the Plan. 515 Page 4 of 4 Proffers & Staff Comments: Proffers (Revised 12/11/24) Staff Comment Permitted uses exclude “hotels and/or motels, fast food restaurants, and gasoline service stations,” however it does not exclude all B2 uses other than self-storage, which leave many other uses such as car washes, retail trade, and personal care services. This proffer restricts some of the B2 permitted uses but leaves many that could generate a higher number of trips and higher water and sewer demand. It would be clearer and more straightforward to restrict all B2 uses other than self-storage in the proffers as self-storage is the stated desired use for this property. “If the cumulative average weekday traffic volume exceeds 120 TPD, then it is agreed that the applicant shall not file an additional site plan application until the County is satisfied that adequate and manageable levels of average weekday traffic volume will exist on internal, and more importantly, state roadways. The applicant shall perform an updated TIA of the project when the proposed ITE traffic projection exceeds 120 TPD (average weekday volume).” The transportation proffer language is not clear. There are no internal roadways proposed for this project, only the entrance and parking lot. The sentence discussing not submitting an additional site plan adds confusion on if the TIA will be conducted for the initial site plan submission or solely and future additional site plans (expansions or changes of use). Staff feels a TIA is not warranted given the size of the property. The larger concerns for this site are the safety of the corridor and entrance and the high speeds travelled along Route 7, which are not the main focus of a TIA. Following a public hearing, staff is seeking a recommendation from the Planning Commission to forward to the Board of Supervisors on this rezoning application. 516