Loading...
HomeMy WebLinkAbout05-07 Snowden Bridge - Revised Road Modifications Stonewall - BackfileMASTER DEVELOPMENT PLAN -TRACKING SHEET (Note: The application does not need to be complete to be accepted but will not be scheduled for the PC or BOS until all items have been received.) Submission Package Comment sheets from the following agencies along with any marked copies of the plan: ✓ VDOT County Engineer Fire Marshal Sanitation Authority ✓ Inspections Dept. Health Department City of Winchester ✓ GIS (Mapping) `---- Parks & Recreation One copy of the master development plan application. Winchester Regional Airport Appropriate number of blueprint plans, colored maps, etc. to cover the PC and BOS meetings. Submission Fee Date L6I!LO ( o A)A AA NOTES: TRACKING Application received Fee Paid (amount: $ o21)0 d o0 ) Preliminary MDP heard by Planning Commission - Action taken: Preliminary MDP heard by Board of Supervisors - Action taken: Letter to applicant regarding Board action and revisions (if required). Final MDP submitted with review agency, PC and BOS comments addressed. Final MDP signed by County Administrator and Planning Director (send two copies to applicant). Administratively approved; letter sent to applicant. 11 DATE: File opened. Reference Manual updated/number assigned. D-base updated. List of adjoiners given to staff member for verification. One black & white location map requested from Mapping & Graphics. Four sets of labels requested from Data Processing. 07 File given to Renee' to update Application Action Summary. CLOSE OUT FILE: Approval (or denial) letter mailed to applicant (*Note: Be sure Joe Wilder in Public works and Jane Anderson in Real Estate receive a copy of the administrative approval letter. Jane wants a copy of the final action letter even if the application was denied or � I(7 withdrawn.) "a "withdrawn." stamped roved"/"denied" or File PP Reference Manual updated. D-base updated. �Z �7 i e given to Renee' for final update to Application Action Summary. *LIM File in file drawer. U \Caro1 Common\Tracking shag\TRACKING. MDP Rev W1110J 11 U DATE NO.7067 4-1 No RECEIVED FROM ----- — ' ) . 1 I IYA c O N P C.�l�' 0 a� ADDRESS � DOLLARS $ co W °' l Q N FOR REN ^N- , 1' I Qc qV-A ❑FOR 4y'A..� ., ~ � GAS.13 �J AMT. OF p� 1 � bA ACCOUNT CHECK (�MONEY AMT. PAID MONE Y •r' '7 V \O BALANCE ORDER f DUE 'd A O FILE C _ o 0 COUNTY of FREDERICK Department of Planning and Development 540/665-5651 FAX: 540/ 665-6395 April 17, 2007 Mr. Mark Smith Greenway Engineering 151 Windy Hill Lane Winchester, Virginia 22602 Re: Administrative Approval of Revised Master Development Plan 905-07 Snowden Bridge: Landbay III A — Part A Property Identification Number: 44-A-31, 31A, 292 & 293 (Zoning: R4) Dear Mr. Smith: Frederick County administratively approved the above -referenced revised master development plan on April 16, 2007. The master development plan is approved for the development of 415 sinale- family detached, 110 single-family attached (townhouses), 214 multi -family units, an active adult community center, recreational center, and park on a net site area of 231.0 acres within the Stonewall Magisterial District. The property which would comprise this development is located on the south side of Old Charles Town Road (Route 761). All requirements of the Frederick County Zoning and Subdivision Ordinances have been satisfied in the approved final master development plan, including approval by all relevant review agencies. I am providing you with seven (7) signed copies of the approved revised master development plan. Please make sure these plans are distributed accordingly. Please note that approval of a subdivision design plan is required prior to the subdivision or development of this parcel. Sincerely, Bernard S. Suchicital Planner I Attachments BSS/dlw cc: Charles S. DeHaven, Jr., Stonewall District Supervisor John Light and Gary Oates, Stonewall District Planning Commissioners Jane Anderson, Real Estate Commissioner of Revenue John Trenary, Building Inspections Joe Wilder, Public Works . Brookfield Stephenson Village, LLC,8500 Executive Park Ave., Ste. 3 0,Fairfax,VA 22031 Stephenson Associates, LC, P.O. Box 2530, Winchester, VA 22604 107 North Kent Street, Suite 202 • Winchester, Virginia 22601-5000 GREENWAY ENGINEERING BAN 2 6 2007 151 Windy Hill Lane Founded in 1971 Winchester, Virginia 22602 TRANSMITTAL Project Name: Snowden Bridge -Master Development Plan File No: 2760B Date: January 26, 2007 To: FC Planning Attn: Bernie Suchicital Copied Delivery: F Fed Ex ❑ Other_ ❑ U.S. Mail From: Kurt Pennington/dlm GREENWAY ENGINEERING Phone: 540-662-4185 Fax: 540-722-9528 JW7 Courier ❑ Pick Up ❑ Urgent PJ For Your Review 0 As You Requested P1 Please Comment Message Bernie, Attached is the following for your review and approval: -2 copies of the revised Master Development Plan -Copy of GIS road name approval letter Thank you for your assistance. Contact us with any questions. Hand Delivery and Pick Ups Only: Received by: Date: Please Print Name: N DEPT. OF GEOGRAPHIC INFORMATION SYSTEMS FREDERICK COUNTY, VIRGINIA W E STREET NAME COMMENTS. SUBDIVISION COMMENTS S DATE: January 22, 2007 SUBDIVISION- Snowden Bridge, Section U STAFF MEMBER: Annie Cahill, GIS Technician APPLICANT: Greenway Engineering ATTN: Kurt Pennington 151 Windy Hill Ln Winchester, VA 22602 COMMENTS: The Frederick County Department of GIS has reviewed the requested road names for use by the subdivision and has made the following determinations: 1. The following road names have been APPROVED and ADDED into the Frederick County Road Naming and Structure numbering system: Splendour Garden Way . 2. The following road names are USABLE in the Frederick County Road Naming and Structure Numbering System: Crofton Dr Redcort Dr Ballarat Dr Norland Knoll Dr 3. The following road names are DENIED use because of conflict, either by spelling or by phonetics, with road names already in the Frederick County Road Naming and Structure Numbering System: Orchard Overlook Dr 4. Structure numbering will be assigned during the pennitting.and construction phase of development. 5. Road names are not approved and accepted into the Frederick County Road Naming and Structure Numbering System without plats or plans delineating location, access from current road system, location, entire length Frederick County Departrnent of GIS, 107 North Kent Street, Winchester, VA 22601, (.540)6(�S.l j ;Ij j JAN 2 5 2007 :� I V , GREENWAY ENGINEERING [ 151 Windy Hill Lane Founded in 1971 Winchester, Virginia 22602 TRANSMITTAL Project Name: Snowden Bridge -Master Development Plan Revision File No: 2760B F E B 2 6 2007 Date: February 23, 2007 To: FC Planning Attn: Bernie Suchicital Copied Delivery: r Fed Ex ❑ Other_ ❑ U.S. Mail From: Kurt Pennington/dlm GREENWAY ENGINEERING Phone: 540-662-4185 Fax: 540-722-9528 0 Courier ❑ Pick Up ❑ Urgent 0 For Your Review F As You Requested EVI Please Comment Message Bernie, Attached is the following for final approval and signature: -10 copies of the master development plan revision with owners' signatures As always, thank you for your assistance. Call with any questions or need for additional information. Hand Delivery and Pick Ups Only: Received by: Date: Please Print Name: APPLICATION MASTER DEVELOPMENT PLAN Department of Planning and Development Use Only. Date application received V-0/0-1 Complete. Date of acceptance Incomplete. Date of return Application # 05-07 1. Project Title: Snowden Bridge -Master Development Plan LB IIIA — Part A 2. Owner's Name Stephenson Associates, LC Brookfield Stephenson Village, LLC (Please list name of all owners or parties in interest) 3. Applicant: Greenway Engineering Address: 151 Windy Hill Lane Winchester, VA 22602 Phone Number: 540-662-4185 4. Design Greenway Engineering Company: Address: Same Phone Number: Same Contact Name: Kurt Pennington 5. Location of Property The property is located on the south side of Old Charles Town Road (Rt. 761) and Jordan Springs Road (Rt. 664) and east of Milburn Road (Rt. 662) Total Acreage: 285.5 acres 7. Property Information a) Property Identification Number (PIN): b) Current Zoning: c) Present Use: d) Proposed Uses: e) Adjoining Property Information: North South East West 44-A-292, 44-A-293, 44-A-31, 44-A-31 A R4-Residential-Planned Community Residential -Undeveloped Residential -Planned Community Property Identification Property Uses Numbers On File f) Magisterial District: Stonewall 8. Is this an original or amended Master Development Plan? Original ❑ Amended I have read the material included in this package and understand what is required by the Frederick County Department of Planning and Development. I also understand that the master development plan shall include all contiguous land under single or common ownership. All required mate ' will be completed prior to the submission of my master development plan a plicati I Signature: Date: _ _F�r- Snowden Bridge, Section 11 Page 1 of 2 C , Kurt D. Pennington From: Funkhouser, Rhonda [Rhonda. Fun khouser @ VDOT.Virginia.gov] on behalf of Ingram, Lloyd [Lloyd.Ingram @ VDOT.Virginia.gov] Sent: Wednesday, February 21, 2007 1:03 PM To: Kurt D. Pennington Cc: Ingram, Lloyd; mcheran@co.frederick.va.us; Baluch, Stephen; Mark D. Smith; Copp, Jerry Subject: FW: Snowden Bridge, Section 11 This is to acknowledge receipt of your revised plans with latest revisions dated 1/11/07 for the referenced project. The application for subdivision of this property appears to have little measurable impact on Snowden Bridge Blvd., the new roadway which would provide access to the property. This section of street is currently not in the State's Secondary Road System. The construction of the street entrance at Snowden Bridge Blvd. has been included and approved as part of the Snowden Bridge Blvd. roadway plans. Since none of the streets in this section are proposed for acceptance into the State Secondary System, as indicated in your January 15, 2007 transmittal, we did not do a detailed engineering review of the roadway design. Should any of the streets subsequently be proposed for acceptance by VDOT, it will be necessary to resubmit the plans for VDOT approval prior.to construction. We offer the following comments for your consideration: 1. On sheet 1 we would recommend a note be added in the 'Project Information: section to clarify, as stated in your January 15, 2007 transmittal, that'AII streets for this section will be private'. Rather than removing the many references to the VDOT Inspector throughout the plans, e.g. on roadway cross section drawings, we would recommend a further note to indicate that 'References to the VDOT Inspector are not applicable to the construction of all private roadways in this section'. 2. On all sheets, is 'SPIENDOUR GARDEN' supposed to be 'SPLENDOUR GARDEN'? 3. On sheets 11-13, the note about CD-1 underdrains should read as follows: CD-1 underdrains are required at the lower end of cuts; CD-2 underdrains are required at roadway sags; all underdrains are to be tied to DI structures. 4. On sheets 11-13, sight lines should be shown at all street and alley intersections, and easements should provided where needed to preserve adequate intersection sight distance. 5. On sheets 11-12, for sidewalks less than 5 feet wide, minimum 5-foot x 5-foot passing areas need to be provided every 200 feet (VDOT IIM-LD-55.8, Rev. 4/12/06, page 2), e.g. along one side of Orchard Overlook Drive and Haversack Ct. 6. On sheet 12, at the intersection of Ellison Way and Astrugal Dr., add one CG-12C (or CG-12B) curb ramp along Ellison Way opposite one of the CG-12A ramps at Astrugal Dr. 7. On sheet 13, at the intersection of Ellison Way and Detachment Dr., add one CG- 12C (or CG-12B) curb ramp along Ellison Way opposite one of the CG-12A ramps at ,.�',W: Snowden Bridge, Section Page 2 of 2 Detachment Dr. 8. On sheets 23-28 in the roadway cross section drawings, the note about CD-1 underdrains should read as follows (same as noted above): CD-1 underdrains are required at the lower end of cuts; CD-2 underdrains are required at roadway sags; all underdrains are to be tied to DI structures. 9. On sheets 23-28 in the roadway cross section drawings, UD-4 underdrains would typically not be required by VDOT for local subdivision streets with less than 1,000 ADT (VDOT Pavement Design Guide for Subdivision and Secondary Roads, Rev. 2000, p. 18). 10. On sheets 23-28 in the roadway cross section drawings, we would recommend a slight adjustment of the fire hydrant location to allow at least a 1-foot offset from the edge of sidewalk. Objects closer than 1 foot to the sidewalk pose a snagging hazard and reduce the effective width of the sidewalk. It appears a 1-foot offset to the sidewalk would still allow for the VDOT minimum offset of 1.5 foot from the face of curb. 11. On sheet 29, in the storm sewer profiles, storm structures STR-2 and STR-3 would require VDOT standard DI-4CC for use with pipe greater than 30". 12. On sheet 29, in the storm sewer profiles, storm structures STR-5 would require VDOT standard DI-413 for use with pipe greater than 30". 13. On sheet 36, add VDOT standard sheets DI-4A,413,4C (sheets 1 and 2) and DI- 4AA,4BB,4CC (1 sheet). Thank you for allowing us the opportunity to comment. If you have any questions concerning any of the comments, please call me or Mr. Stephen Baluch at the VDOT office in Winchester at 540-535-1829. <<CommentSheet.pdf>> Lloyd A. Ingram Transportation Engineer VDOT N Edinburg Residency Land Development 14031 Old Valley Pike Edinburg, VA 22824 (540) 984-5611 (540) 984-5607 (fax) 3/22/2007 Control number MDP06-0008 Project Name Snowden Bridge Sections 2 & 3 Address 151 Windy Hill Ln. Type Application Subdivision Current Zoning R4 Automatic Sprinkler System No Other recommendation Emergency Vehicle Access Adequate Siamese Location ' --'-rick County Fire and Rescue Department Dffice of the Fire Marshal an Review and Commentsr�p���l�i�1„ Date Revised Date received Date reviewed 3/20/2006 4/5/2006 Applicant Greenway Engineering Applicant Phone City State ZIP 540_662.4185 Winchester VA 22602 Tax ID Number Fire District 44-A-293, 31 A 13 Emergency Vehicle Access Comments Access Comments Additional Comments Plans approved as submitted. Recommendations Automatic Fire Alarm System No Requirements Hydrant Location Adequate Roadway/Aisleway Width Adequate Rescue District 13 Election District Stonewall Residential Sprinkler System No Fire Lane Required No Special Hazards No APR 1 2 2006 )-7 (PC) w� Plan Approval Recommended Reviewed By Signature Yes J. Neal Tip ((( - -- - - Flit MAR N A�- FREDERICK CO REQUEST FOR CONDITIONAL SUBIDVISION COMMENTS Frederick County Inspections Department ATTN: Building Official 107 North Kent Street Winchester, Virginia 22601 (540)665-6350 The Frederick County Inspections Department is located at 107 North Kent Street, 4th Floor of the County Administration Building in Winchester, if you prefer to hand deliver this review. Applicant's name, address and phone number: 1 Windy Hill Lane Name of development and/or description of the request: Snowden Bridge Subdivision - Section 11 Location: East of Snowden Bridge Boulevard. Approximately 0.8 miles South of Old Charles Town Road Inspection Department Comments: �Fi7u�Z: �fT--_ �r�arLl��.T�13�-<s�i�TlT7 Code Administrator Signature and Date: ` " ` U7 (NOTICE TO INSPECTIONS DE PLEASE URN THIS Fpf& TO A L(CANT.) NOTICE TO APPLICANT It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Also, please attach a copy of your application form, location map and all other pertinent information. k( n o 0 001 a Dwellings shall comply with The Virginia Uniform Statewide Building Code and The International Residential 2003 Codes. Additional Engineering shall be required on lots#3,and 17 due to slopes and fill material. Backwater valves shall be installed on all plumbing fixtures, (subject to back sewer), located below the top elevation of the upstream man hole cover. Fire rating on exterior walls per section 602 IBC on dwellings located on property lines. COUNTY of FREDERICK rc Department of Public Works 540/665-5643 FAX: 540/ 678-0682 March 16, 2007 Mr. Kurt Pennington Greenway Engineering 151 Windy Hill Lane Winchester, Virginia 22602 Re: Review Comments -. Snowden Bridge Section 11 Frederick County, Virginia Dear Kurt: Upon review of the subject plan, we offer the following comments: 1. Please refer to the previous comment 1. Refer to sheet 5, paragraph 3 under "vegetative measures." Stabilization should be immediate per Minimum Standard 5. 2. Remove the Outlet Protection Table at the bottom of Sheet 30. The correct table is now located on Sheet 31. Due to the minor nature of these comments, the Frederick County Public Works Department recommends approval of the subject site plan. All remaining comments shall be addressed prior to Land Disturbance Permit application. Once these comments have been addressed please submit a complete set of the revised plans for our records. Please highlight on the revised plans the changes listed above. Sincerely, Joet. Wilder Deputy Director JCW/mlr cc: Mark Cheran, Zoning and Subdivision Administrator file MAR 1 9 2007 ley�lxl, 107 North Kent Street • Winchester, Virginia 22601-5000 FOR CONDITIONAL SUBIDVISIO Frederick County Parks and Recreation Dept. Attn: Director of Parks and Recreation 107 North Kent Street Winchester, Va. 22601 (540)665-5678 The Frederick County Parks and Recreation Department Street, is located on the second floor of the Frederick Winchester, if you prefer to hand deliver this County Administration Building, 107, North Ken review form. Applicant's name, address and phone number: Greenwa En ineerin 151 Wind Hill Lane, Winchester, VA 22602 540-662-4185 Name of development and/or description of the request: Snowden Brid e Sections 2 and 3 Location: Ste henson Vir inia off of Old Charles Town Road Parks and Recreation Department Comments: Parks and Recreation staff made comments and recommendations re arding open space, proffers and recreational units during the rezoning and master development review phases of this project. The Planning Department will ensure all requirements are met an t e ar s an Recreation Department will review and make recommendations s. Also, on the des i n of the trails communit consideration must be given to the possibility of Route 37 displacing agreed upon and required open space, trhls and dot rece�t� 1 facilities d areas. In the ov (over) Parks Signature and Date: (NOTICE TO PARKS *PLEAS RETURN THIS FO M TO APPLI NOTICE TO APPLICANT It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Also, please attach a copy of your application form, location map and all other pertinent information. N DEPT. OF GEOGRAPHIC INFORMATION SYSTEMS i4 FREDERICK COUNTY, VIRGINIA w E STREET NAME COMMENTS SUBDIVISION COMMENTS i? S DATE: January 22, 2007 SUBDIVISION: Snowden Bridge, Section 11 STAFF MEMBER: Annie Cahill, GiS Technician APPLICANT: Greenway Engineering ATTN: Kurt Pennington 151 Windy Hill Ln Winchester, VA 22602 COMMENTS: The Frederick County Department of GIS has reviewed the requested road names for use by the subdivision and has made the following determinations: t. The following road names have been APPROVED and ADDED into the Frederick County Road Naming and Structure numbering system: Splendour Garden Way 2. The following road names are USABLE in the Frederick County Road Naming and Structure Numbering System: Crofton Dr Redcort Dr Ballarat Dr Norland Knoll Dr 3. The following road names are DENIED use because of conflict, either by spelling or by phonetics, with road names already in the Frederick County Road Naming and Structure Numbering System: Orchard Overlook Dr 4. Structure numbering will be assigned during the permitting and construction phase of development. 5. Road names are not approved and accepted into the Frederick County Road Naming and Structure Numbering System without plats or plans delineating location, access from current road system, location, entire length Frederick County Departrnent of G1S, 107 Kent Street, Winchester, VA 22601, JAN 2 0 zuu' REQUEST FOR CONDITIONAL SUBDNISION COMMENTS Frederick County Department of GIS Attn: Marcus Lemasters, GIS Manager 107 North Kent Street Winchester, Va. 22601 (540) 665-5651 The GIS Manager will review the proposed street names for this project to ensure their acceptability into the Frederick County Street Name System. Proposed street names will also be routed through the Communication Center Supervisor for review. This step will prevent duplicate street names from being entered. Please attach one, copy of the plan indicating proposed names. Applicant's name, address and phone numher: 151 Windy W-662-41 Name of development and/or description of the request: Snowden Bridge Subdivision Sec 4 Location: Off Snowden Bridge GIS Department Comments: �� FFa 2 o zflo� By- T FOR CONDITIONAL SUBDIVISION Frederick County Department of GIS Attn: Marcus Lemasters, GIS Manager 107 North Kent Street Winchester, Va. 22601 (540)665-5651 The GIS Manager will review the proposed street names for this project to ensure their acceptability into the Frederick County Street Name System. Proposed street names will also be routed through the Communication Center Supervisor for evie indicating proposed revent names. duplicate street names from being entered. Please attach one copy of p Applicant's name, address and phone number: Greenway. Engineering 151 Windy Hill Lane, Winchester, VA 22602 540-662-4185 Name of development and/or description of the request: Snowden Bridge Sections 2 and 3 Location: Stephenson Virginia off of Old Charles Town Road GIS Department Comments: quo Neu/ 12e,4t) Ivps»ES o2 cg--, 6a f?c-qulea - jY�tE /ZoAfl .✓A-"64 G✓f2E p'AlZT J7rSHSor✓ ,42 o/ ��ev7iEO r¢S pip t Dig ,a.2d £�� f��2 rid u r1 r�i 6/1 v2 C Awn .¢Gs�RE l� G�n2pt�sNr 4 Linsre.�k- A2. �a eN�d�er�rl�' 1%2. xr�.�J�Or1• r�f�?��T �T�E• 43E 14L55i(o/V i4 r7lE 13cuc0i/� Date received a3- Date revision received ____ __ Date approved Incomplete ____ Incomplete Date reviewed o3-24' °b Date reviewe Signature & Date: Signature & Date (revi ion): MAR 2 2 2006 c271eag 40 Department of Planning and Development 540/665-5651 FAX: 540/665-6395 March 12, 2007 Greenway Engineering Attention: Mark Smith 151 Windy Hill Lane Winchester, VA 22602 RE: Preliminary Revised Master Development Plan Review Comments: Snowden Bridge Property Identification Numbers (PIN): 44-A-31A, 292, and 293 Dear Mr. Smith: Please adequately address each of the comments listed below prior to formal submission of the preliminary master development plan referenced above. Preliminary Review Comments: 1. On Sheet 1 of 19, place a notation to indicate changes will affect Land Bay IIIA Part A only. 2. On Sheet 4 of 19, amend the last Land Bay Breakdown Narrative. As per a telephone discussion, the affordable housing units will not be located within Section 11. 3. On Sheet 4 of 19, retype the Land Bay table. 4. On Sheet 6 of 19, insert "to date" to the titles of tables 1-7. 5. On Sheet 6 of 19, according to Rezoning #06-03 — modification #1, 594 acres are identified to be utilized for residential land use within Stephenson Village (Snowden Bridge). Please include this note. Also, the rezoning proffered a maximum of 356.4 acres (60%) as a total for "Other Unit Types" within the same table. Please correct. 6. On Sheet 6 of 19, include the following note for Table 4: "Modification 44 — The value of one recreational unit shall be equivalent to the value of one recreational tot lot unit described in Section 165-64B(1) of the Frederick County Zoning Ordinance." 107 North Kent Street, Suite 202 a Winchester, Virginia 22601-5000 I • Mr. Mark Smith Re: Snowden Bridge MDP March 12, 2007 Page 2 7. On Sheet 6 of 19, insert a new column for the Exhibit E table, identifying in which land bay each housing unit is allowed to be located. Please address the identified corrections as highlighted on the MDP for this table. 8. On Sheet 7 of 19, the 20 foot linear park trail easement is too vaguely marked. Please bold this out. 9. On Sheet 10 of 19, on the North Stephenson major collector road typical road cross section, for continuity, insert a five foot grass strip in between the C&G and the major collector road, and provide for a bike lane along both sides of the road. 10. On Sheet 11 of 19, amend the typical road buffer detail by replacing it with a typical that was provided for Section 1 of Snowden Bridge. 11. On Sheet 12 of 19, note that there are no floodplains within the project site of Land Bay IIIA — Part A. 12. On Sheet 13 of 19, move the Pedestrian Trail Detail and neighboring notes over so that the page border does not cross the text. Provide easement information for the Pedestrian Trail System (PTS) onto tax map parcel 44-A-31. Bold the entire length of the PTS. Align the PTS at the Sawtooth Drive crossing. Move the PTS in between Sawtooth and the Boulevard north so that it lies within the MDP project site. Connect the PTS across the Boulevard from Section I and the recreation center site east of the Boulevard. Remove the mention of the PTS into the remainder of Land Bay III (east of Patchwork Drive). 13. On Sheet 13 of 19, identify each street as either a public street or a private street. Sketch all private alley intersections alike. Indicate all planned interparcel connectors. 14. On Sheet 13 of 19, continue Flyfoot Drive north to Land Bay 1 (school site), as shown on the approved MDP. Is the private alley connecting Garret Court and Dutchman Court, east of the Boulevard, a private street? If so, please provide a street name. 15. On Sheet 13 of 19, explain or remove the highlighted bold lines running across the diagram. 16. On Sheet 13 of 19, provide a 10' buffer detail. Please ensure that all comments are addressed when revising the MDP. Once all comments have been addressed and review agency comments received, you will need to submit a complete MDP application, a signed and notarized Special Limited Power of Attorney Form to this department. • f Mr. Mark Smith Re: Snowden Bridge MDP March 12, 2007 Page 3 Once this information is received, staff will schedule the MDP to be presented to the Planning Commission as a FYI item. I have attached a marked copy of the plans to assist with the revisions. Once this department receives all agency approval comments, we will then schedule this MDP through the normal approval process. Review comments are required from the following agencies: Frederick County Fire Marshal, Frederick County Department of Building Inspections, Frederick County Department of Public Works, Frederick County Department of G.I.S, Frederick County Sanitation Authority, and the Virginia Department of Transportation. Please do not hesitate to contact me with questions regarding this letter. Sincerely, Bernard S. Suchicital Planner I Attachment BSS/bad cc: Brookfield Washington, LLC, 8500 Executive Park Ave., Ste. 300, Fairfax, VA 22031 r� FREDERICK COUNTY SANITATION AUTHORITY SITE PLAN REVIEW COMMENTS Project 5i,vo wlz;)Fw Engineer �/ W15 Yk REVIEW STATUS review number correct & resubmit approved as noted-) number of items to be corrected approved DRAWINGS send me by q a40A54f L✓g 1. one full set of prints 7 3 .;^ -� 9 2. two separate CD's of plan sheets 1A 3 A a) one CD of above noted sheets in PDF format, with one sheet per file, landscape orientation, and with a name for each file that describes the project name and the sheet number b) one CD of above noted sheets in DWG format, with one sheet per file, landscape orientation, and with a name for each file that describes the project name and the sheet number c) each CD shall be labeled with its format and project name, and placed in a CD sleeve EASEMENTS Y I No I need a copy of the recorded onsite Y A I need a copy of the recorded offsite water and / or sewer easement(s). water and / or sewer easement(s). I need a copy of the recorded deed(s) of easement before service will be authorized. OTHER Y N % This project also requires DEQ approval. Y /11Z This project also requires VDH approval. Date: John G. Whitacre - Senior Engineer OCT O6 GREENWAY ENGINEERING 151 Windy Hill Lane APR Founded in 1971 Winchester, Virginia 22602 TRANSMITTAL Project Name: Snowden Bridge File No: 2760B Date: Thu, Apr 5, 2007 To: FC Planning Attn: Bernie Suchicital Copied Delivery: F Fed Ex 7 Other_ F U.S. Mail From: Kurt Pennington/reb GREENWAY ENGINEERING Phone: 540-662-4185 Fax: 540-722-9528 FvJ Courier C1 Pick Up 5 2M r] Urgent rv7 For Your Review r7 As You Requested M Please Comment Message Bernie, Please find attached the following items: - Revised MDP Application - $2,000.00 Fee check - Agency approval letters - Sections 2, 3, 4, 11 (Note: No Section 1 approvals are provided: Section 1 plans are fully approved) - MDP - 10 sets of sheets 15-18 Thank you for your assistance with this project. Contact us with any questions or need for additional information. Hand Delivery and Pick Ups Only: Received by: Date: Please Print Name: GREENWAY ENGINEERING 151 Windy Hill Lane Founded in 1971 Winchester, Virginia 22602 TRANSMITTAL Project Name: Snowden Bridge -Revised Master File No: 2760B Date: March 27, 2007 To: FC Planning Attn: Bernie Suchicital Copied Delivery: r Fed Ex r] Other_ C] U.S. Mail ent Plan From: Kurt Permington/dlm GREENWAY ENGINEERING Phone: 540-662-4185 Fax: 540-722-9528 Courier C] Pick Up C] Urgent rv7 For Your Review M As You Requested (F Please Comment Message Bernie, Per your request, attached is the following for final approval and signature: -10 copies of the revised sheets per Planning comments -Comment response letter -Approval letters from Public Works and VDOT for Section 11 NOTE: Please insert these revised sheets into the copies you already have. Thank you for your assistance. Call with any questions. Hand Delivery and Pick Ups Only: Received by: Please Print Name: Date: MAR 2 7 2007 11 Document Approval Form PLEASE REVIEW THE ATTACHED DOCUMENT. IF THIS DOCUMENT MEETS YOUR APPROVAL PLEASE INITIAL IAL AND PROVIDE THE DATE AND TIME OF YOUR APPROVAL. IF THIS DOCUMENT DOES NOTMEET YOUR APPROVAL PLEASE PROVIDE COMMENTSAS TO WHAT YOU WOULD LIKE TO HAVE COMPLETED. INITIALS DATE & TE%IE Candice Bernie Mark Susan Eric Mike Kevin John Lauren COMMENTS: Received by Clerical Staff (Date & Time): R D 4 14 L- U:\Pam\Common\Document Approval Form.wpd MDP #05-07 SNOWDEN BRIDGE - RAE Stonewall ROAD MODIFICATION Please note: The Subdivision/MDP plans associl.ted