Loading...
HomeMy WebLinkAboutFile Summit, Section 5 Gainesboro - BackfileN �;UM177/i C5� WATER AND SEWERA(UE SYSTEM REPORT AND SPECIFICATIONS LAKE HOLIDAY ESTATES SECTION I ADD]TION Frederick County, Virginia September 8, 1994 COMMONWEALTH OF VIRGINIA Department of Health Office of Water Programs Lexington Field Office (%/ Plans & Specifications . (VApproved () Operations & Maintenance Manual () Conditionally () Addendum Approved () Change Order () Disapproved () Revised Plan Sheet(s) () Revised Specification Sheet(s) () Sludge Management Plan Date Engineering Field Director 41, �Ee Prepared for: Oonald L. Bayliss Lakeshore Development Y 67 / Winchester, VA 24494- 3 ylo )- Prepared by LEWIS & ASSOCIATES `4 East Piccadilly Street Winchester, VA 22601 'el.: (703)722-9377 Fax.: (703)662-1861 1'1- ject No. 94-036 4O' Yt(h n1 THY , a ' U / / <' 4. 021 �s',S r yC}1 d .. ONAI ; 3 LAKE HOLIDAY ESTATES SECTION IC WATER AND SEWERAGE SYSTEM TABLE OF CONTENTS section page 1.0 EXECUTIVE SUMMARY 2 2.0 WATER SERVICE 2 3.0 SANITARY SEWER SERVICE 2 3.1 General Description 2 3.2 Individual Grinder Pumps 2' 3.3 Force Main 3.4 Lift Station 3 3 APPENDIX 4 page 1 LAKE HOLIDAY ESTATES SECTION IC 1.0 EXECUTIVE SUMMARY 45) This report is intended to provide design and construction d ails for a �p ed water service and sanitary sewer service system for Section 4E-�at !a t�Eday Estates, The Summit, in Cross Junction, Virginia. This report should be reviewed in conjunction with a set of drawings titled "LAKE HOLIDAY ESTATES -SECTION 4e* b,��,,11 LEWIS & ASSOCIATES. Section Mis a proposed 4 lot single family home subdivision. Lot owners in Section �� will be subject to and the beneficiaries of all covenants, restrictions and privileges n010associated with Lake Holiday Country Club, Inc. and Lake Holiday Utility Company. Water and sewer services will be provided by Lake Holiday Utility Company. 2.0 WATER SERVICE Water service will be obtained for each individual lot by connection to existing water mains. Lot 32 will connect to the 8" water main located in the Lakeview Drive right-of-way. Lots 29, 30 and 31 will connect to the 8" water main located in the South Lakeview Drive right-of-way. Each lot will be supplied by a 3/4" copper waterline connected directly to the main or to a V service line connected to the main. Fire flow can be obtained from an existing hydrant located at the northeast corner of the intersection of South Lakeview Drive and Lakeview Drive. 3.0 SANITARY SEWER SERVICE , iom 3.1 General Description �A /�ppi7t The four lots proposed for Section will be connected to the collection and pumping system designed for Section 1B. The specifications for this system are contained in the "WATER AND SEWERAGE SYSTEM REPORT AND SPECIFICATIONS" for Section 1B, Lake Holiday Estates�ia ed Margh 1 9 y LEWIS & ASSOCIATES. Each home built in Section4491A e quipped man individual sump and grinder pump designed to convey sewage to a low pressure force main. The force main will discharge into the gravity collection system in Section 1B. The capacity of the sewage lift station designed for Section 1B is adequate to handle the increased ow resulting from the addition of the four lots in Section- / - I? FAA; 710•P-j 3.2 Individual Grinder Pumps The holding tank and grinder pump units for each home shall be the Series GP 210 by EnvironmentlOne Corporation. See specifications and cut sheets contained in the Appendix. page 2 LAKE HOLIDAY ESTATES SECTION IC 3.3 Force Main The force main called for on the plans shall be SCH 40 PVC pipe-ASTM D 1784 with solvent weld joints. Installed pipe shall be tested for leakage at a minimum air pressure of fifty percent above the design operating pressure for one hour at zero leakage. The testing pressure head shall be 19.5 psi as derived from the following formula. P = .65(H); H = 29.l' TDH 3.4 Lift Station A Class 2 sewage lift station is presently under construction in Section 113. The original design called for a 42" diameter wet well. The wet well installed is 48" in diameter. Lift station duplex pumps will convey the sewage from a total of 32 lots to the sewage treatment plant. The revised lift station data are shown below. STATION DATA pump elevation: force main high point: elevation head: force main length: friction loss(C=150; .737100' of 2" pipe): minor losses: TDH: average daily flow per lot: average design flow: peak factor: design flow(pump capacity): design velocity: WET WELL DATA well dimensions: volume per foot: drawdown volume: pump cycle: cycles per day: pumps: 820' 880' 60' 1430' 10.4' 1.6' 72' 400 gallons 8.9 gpm 3 31 gpm 3.2 fps 48" dia. x 10'h 94 gallons 188 gallons = 2' 6 minutes x 31 gpm = 186 gallons .69+- @ ADF Piranha V2.5, 3450 rpm, 230V page 3 LAKE HOLIDAY ESTATES SECTION 1C WATER AND SEWERAGE SYSTEM APPENDIX item exhibit no. LOW PRESSURE SEWERAGE SYSTEM HEAD 1 SECTION 1 B GRAVITY SEWER FLOW DATA 2 GRINDER PUMP SPECIFICATIONS 3 page 4 Ad� PROJECT: LAKESHORE ACRES SECTION46 LOW PRESSURE SEWAGE SYSTEM A B C D E F G H I J K L M N BRANCH NO. OF ACCUM. MAX. MAX. PIPE MAX. LINE FRICT. ACCUM. MAX. ELEV. MIN.ELEV. ELEV. MAX. TOTAI NO. PUMPS TOTAL ON FLOW SIZE VEL. LENGTH LOSS F. LOSS MAIN PUMP DIFF. HEAD (gpm) (in.) (fps) (ft) (ft) (ft) (ft) (ft) (ft) (ft) 1 1 1 1 11 1.25 2.88 50 1.41 12.10 845.00 828.00 17 29.10 2 2 3 2 22 1.50 4.00 75 3.131 10.69 845.00 828.00 17 27.69 3 21 5 3 33 2.00 3.37 346.44 7.561 7.56 845.00 828.00 17 24.56 COLUMN REMARKS A branch ID B no. of pumps per branch C total no. of pumps D maximum no. of pumps running simultaneously E maximum flow thru branch @ 11 gpm each F pipe diameter G =(E x 0.002228)/(3.14 x (F/24)^2) H pipe length I =H x (E/(0.281 x 150 x FA2.63))^1.85 J sum of losses from outfall to branch K high point in main L low pump elevation M =K-L N =J+M 06SEP94-LEWIS & ASSOCIATES PROJECT: LAKESHORE ACRES SECTION 1 C SANITARY SEWER LINE DATA -SECTION 1 B REVISIONS LOCATION TOP LINE NO. AVG. FLOWTOT. FLOW PEAK Q PEAK LENGTH INVERT INVERT SLOPE Q CAP V FULL ELEV. FROM TO LOTS GPD GPD FACTOR CFS FT. UPPER LOWER FT/FT CFS FPS MH B7 872.00 137-136 5 2000 2000 3 0.0093 2801 866.00 844.16 0.078 3.41 9.77 MH B6 849.00 136-85 7 2800 4800 3 0,02232 92 844.06 840.38 0.040 2.44 6.99 MH B5 847.00 135-134 1 400 5200 3 0.02418 133 840.281 839.75 0.004 0.77 2.21 MH B4 849.00 134-83 1 400 5600 3 0.02604 109 839.65 824.74 0.137 4.52 12.95 MH B3 828.00 133-132 3 1200 6800 3 0.03162 295 824.64 823.46 0.004 0.77 2.21 MH B2 827.00 132-131 1 400 7200 3 0.03348 76 823.36 823.04 0.004 0.77 2.21 MH B1 827.00 B1-LS 1 4001 7600 3 0.035341 113 822.951 822.501 0.0041 0.77 2.21 06SEP94-LEWIS & ASSOCIATES Simplex and Suggested Specifications ' Duplex Units with and Prefabricated Flooded Suction Grinder Pumps without Accessways INDEX Page General Description ........................................ D-2 Operating Conditions ...................................... D-2 Tank.................................................................. D-3 Integral Accessway.......................................... D-3 CoreUnit.......................................................... D4 Pump................................................................ D-4 Grinder............................................................ D-4 Electric Motor .................................................. D-5 Mechanical Seal .............................................. D-5 CheckValve ...................................................... D-5 Anti -Syphon Valve .......................................... D-5 .................................................... Controls ........ D-5 Redundant Check Valve .................................. D-6 Wiring.............................................................. D-6 Corrosion Protection ........................................ D-6 Serviceability.................................................... D-6 Safety................................................................ D-7 Manufacturer.................................................. D-7 Limited Warranty ............................................ D-7 Note: When specifications for grinder pump models are different in a given section, a separate subsection for each model is included. o-1 General Simplex Grinder Pump Without Accessway Description The contractor shall furnish and/or install one facto built ry- grinder pump core and all necessary parts and equipment installed in a 60 or 120 gallon fiberglass reinforced polyester tank as described in the fol- lowing specifications. Duplex Grinder Pump Without Accessway The contractor shall furnish and/or install one factory -built duplex grinder pump consisting of two grinder pump core units and all neces- sary parts and equipment installed in a 120 gallon fiberglass rein- forced polyester tank as described in the following specifications. Simplex Grinder Pump With Accessway The contractor shall furnish and/or install one factory -built grinder pump consisting of a grinder pump core and all necessary parts and equipment. This shall be installed in a factory -built 60 or 120 gallon fiberglass reinforced polyester tank with integral watertight access - way as described in the following specifications. Duplex Grinder Pump With Accessway The contractor shall furnish and/or install one factory -built grinder pump consisting of two grinder pump core units and all necessary parts and equipment. This shall be installed in a factory -built 120 gallon fiberglass reinforced polyester tank with integral watertight ac- cessway as described in the following specifications. Operating The pump(s) shall be of a semi -positive displacement type and be Conditions capable of delivering 11 gpm against a rated total dynamic head of 92 feet (40 psig). At zero head, the output shall be 15 gpm minimum. The pump(s) shall be capable of intermittent (3 minutes minimum) operation at any heads up to 150% of normal rated dynamic head. The electrical rating of each pump shall be 8 amperes, 1 phase, 240 volt, 60 Hertz. D-2 Tank Simplex - 60 Gallon The tank shall be custom molded of fiberglass reinforced polyester resin and shall have a nominal wall thickness of 346" and a net capac- ity of 60 gallons. The tank shall be furnished with one PVC inlet flange to accept 4" nominal diameter PVC drain -waste -vent (DWV) pipe using the solvent -weld system. The socket fittings shall be se- curely fastened to the tank and shall be leak tight. Simplex -120 Gallon The tank shall be custom molded of fiberglass reinforced polyester resin and shall have a nominal wall thickness of 1/4" and a net capac- ity of 120 gallons. The tank shall be furnished with two PVC inlet flanges providing sockets 180° apart to accept 4" nominal diameter PVC drain -waste -vent (DWV) pipe using the solvent -weld system. These socket fittings shall be securely fastened to the tank and shall be leak tight. The upper surface of the Series 6 tank shall be stiffened by use of inte- grally molded reinforcing ribs and shall be capable of supporting the combined weight of the pump core and a workman. Duplex ,120 Gallon The tank shall be custom molded of fiberglass reinforced polyester resin and shall have a nominal wall thickness of 1/4" and a net capac- ity of 120 gallons. The tank will be fitted with an integral fiberglass baffle dividing it into two compartments which interconnect just below the elevation of the inlet fitting inverts. The tank shall be furnished with two PVC inlet flanges providing sockets 1800 apart to accept 4" nominal diameter PVC drain -waste -vent (DWV) pipe using the sol- vent -weld system. These socket fittings shall be securely fastened to the tank and shall be stiffened by use of integrally molded reinforcing ribs and shall be capable of supporting the combined weight of the pump cores and a workman. Integral Simplex Accessway The accessway shall be an integral extension of the tank. It shall have an access opening at the top to accept a lockable cover. The accessway shall include the following factory supplied items: Grinder pump discharge extension with a surface operable, positive sealing, quick disconnect coupling, and a full ported shut-off valve terminating in a watertight bulkhead fitting with external 1 1/4" male pipe thread. Internal wiring shall terminate in a sealed junction box, integral with the accessway and suitable for outdoor use. _i� Duplex The accessway shall be an integral extension of the tank. It shall have an access opening at the top to accept a lockable cover. The accessway shall include the following factory supplied items: Grinder pump discharge extension(s) terminating in watertight bulkhead fitting(s) with external 1 1/4" male pipe thread. Internal wiring shall terminate in sealed junction boxes integral with accessway and suit- able for outdoor use. Core Unit The grinder pump shall have cartridge type easily removable core as- semblies containing pump, motor, grinder, controls, check valve, anti - syphon valve and wiring. The watertight integrity of the core unit, including wiring and access cover, shall be established by 100% factory test at a minimum of 5 psig. Pump The pump shall be a custom designed, integral, vertical rotor, motor driven, solids handling pump of the progressing cavity type with me- chanical seal. The rotor shall be through -hardened, highly polished, precipitation hardened stainless steel. The stator shall be of a specifi- cally compounded ethylene propylene synthetic elastomer. The mate- rial shall be suitable for domestic wastewater service. Its physical properties shall include high tear and abrasion resistance, grease re- sistance, water and detergent resistance, temperature stability, good aging properties, and outstanding wear resistance. Grinder The grinder shall be positioned immediately below the pumping ele- ments and shall be direct -driven by a single, one-piece motor shaft. The grinder impeller assembly shall be securely fastened to the pump motor shaft. The grinder will be of the rotating type with a stationary hardened and ground chrome steel shredding ring spaced in accurate close annular alignment to the driven impeller assembly, which shall carry two hardened type 400 series stainless steel cutter bars. This assembly shall operate without objectionable noise or vibration over the entire range of recommended operating pressures. The grinder shall be constructed so as to eliminate clogging and jam- ming under all normal operating conditions, including starting. Suffi- cient vortex action shall be created to scour the tank free of deposits or sludge banks which would impair the operation of the pump. These requirements shall be accomplished by the following actions in con- junction with the pump: 1) The grinder shall be positioned in such a way that solids are fed in an up -flow direction. 2) The inlet shroud opening shall have a diameter no less than 5 inches. 3) At maximum flow, the average inlet velocity should not exceed 0.2 feet per second. 4) The cutter bars shall extend 0.200 to 0.250 inch above the impel- ler disc. 5) The impeller disc shall rotate at a nominal speed of 1725 rpm. D-4 C The grinder shall be capable of reducing all components in normal do- mestic sewage, including a reasonable amount of "foreign objects", such as paper, wood, plastic, glass, rubber and the like, to finely - divided particles which will pass freely through the passages of the pump and the 1 1/4" diameter discharge pipe. Electric Motor The motor shall be a 1 hp, 1725 rpm, capacitor start, ball bearing, squirrel cage induction type with a low starting current not to exceed 36 amperes and high starting torque of 8.4 foot pounds. Inherent protection against running overloads or locked rotor condi- tions for the pump motor shall be provided by the use of an automatic - reset, integral thermal overload protector incorporated into the motor. This motor protector combination shall have been specifically investi- gated and listed by Underwriters Laboratories, Inc., for the applica- tion. Mechanical The core shall be provided with a mechanical shaft seal to preclude Seal leakage between the motor and pump. The seal shall have a station- ary ceramic seat and carbon rotating sealing surface with face preci- sion lapped and held in position by a stainless steel spring. Check Valve The pump shall be equipped with a factory -installed, gravity -operated, flapper -type integral check valve built into the discharge pipe. This valve will provide a full -ported passageway when open, and shall in- troduce a friction loss of less than 6 inches of water at maximum rated flow. A non-metallic hinge shall be an integral part of the flapper assembly, providing maximum degrees of freedom for assured seating even at a very low back pressure. The valve body shall be made of PVC. Anti -Siphon The pump shall be constructed with a positively -primed flooded suc- Valve tion configuration. As added assurance that the pump cannot lose prime even under negative pressure conditions in the discharge piping system, the pump shall be equipped with an integral anti -siphoning, air relief valve in the discharge piping just below the main check valve. This valve will automatically close when the pump is running and open when the pump is off. Controls Necessary controls shall be integral with the grinder pump and shall be located in the top housing of the core unit inside a waterproof access cover. The cover will be attached with stainless steel, tamper- proof fasteners. Non -fouling wastewater level detection for controlling pump operation shall be accomplished by monitoring the pressure changes in an inte- gral, air -bell level sensor connected through air -tight tubing to a pres- sure switch. The level detection device shall have no moving parts in direct contact with the wastewater. Overflow sensing will be accomplished by a separate air -bell sensor of the same type. D-5 Redundant Check Valve (Recommended option) Wiring Corrosion Protection Serviceability Each level control shall have its own built-in fail safe design which will prevent the entrance of moisture into the controls in case of switch diaphragm failure. To assure reliable operation of pressure sensitive switches, each core shall be equipped with a quick disconnect breather assembly, complete with check valve to prevent accidental entry of water into the motor compartment in the event of accessway flooding. An overflow indicator lamp assembly requiring 120 volts and suitable for remote installation in a standard device box will be furnished. This indicator will be mounted on a decorative wall plate 2 3/4" x 41/2" and marked "Grinder Pump Monitor". The grinder pump will be furnished with two ten foot (10) lengths of type OF cable, pre -wired and connected with weatherproof materials. The power supply cable shall be 12-2 W.GR.D., designed for 1 phase, 240 volt, 60 Hertz power supply, and meet UL requirements. The signal cable to the overflow indicator lamp shall be 14-2 W.GR,D., designed for 1 phase, 120 volts, 60 Hertz power supply, and meet UL requirements. Each grinder pump shall optionally include in its package one sepa- rate check valve for installation in the discharge line between the grinder pump and the sewer main to ensure maximum protection against backflow in the event of sewer line break. The valve shall be 1 1/4" and of the gravity -operated flapper type. The check valve will provide a full -ported passageway when open and shall introduce a friction loss of less than 6 inches of water at maximum rated flow. A non-metallic hinge shall be an integral part of the flapper assembly providing maximum degrees of freedom for assured seating at a very low back pressure. The valve body shall be made of PVC compatible with 1 1/4" PVC pipe solvent -weld system. It shall be the responsibility of the electrical contractor to furnish and install, in compliance with appropriate national and local codes, serv- ice entrance equipment and/or branch circuit protection and all wiring to the grinder pump leads. All materials exposed to wastewater shall have inherent corrosion pro- tection; i.e., cast iron, fiberglass, stainless steel, PVC. Any exterior steel surfaces are to suitably protected against corrosion. The grinder pump core unit shall have two lifting eyes provided in the top housing which can be used to facilitate easy removal of the core unit from the tank when necessary. 1,3 0-6 E Safety The grinder pump shall be free from electrical and fire hazards as re- quired in a residential environment. As evidence of compliance with this requirement, the completely assembled and wired grinder pump in its tank shall be listed by Underwriters Laboratories, Inc. The grinder pump shall meet accepted standards for plumbing equip- ment for use in or near residences, shall be free from noise, odor or health hazards, and shall have been tested by an independent labora- tory to certify its capability to perform as specified in either individual or low pressure sewer system applications. As evidence of compliance with this requirement, the grinder pump shall bear the National Sani- tation Foundation seal. Manufacturer The equipment specified shall be the product of a company experi- enced in the design and manufacture of grinder pumps for specific use in low pressure sewage systems. The company shall submit detailed installation and user instructions for its product; submit evidence of an established service support program including complete parts and service manuals; and be responsible for maintaining a continuing in- ventory of grinder pump replacement parts. Limited The manufacturer shall offer a limited warranty which guarantees its Warranty product to be free from defects in material and factory workmanship for a period of two years from date of installation or twenty-seven (27) months from date of shipment, whichever occurs first, provided the product is properly installed, serviced, and operated under normal conditions and according to the manufacturer's instructions. Repair or parts replacement required as a result of such defect will be made free of charge during this period upon return of the defective parts or equipment to the manufacturer or its nearest authorized service center. D-7 FEATURES GP 210 is a complete unit, including grinder pump, check valve, tank and all necessary controls built l into a single unit, ready to connect. All solids are ground to a particle size so fine as to pass easily through the pump, check valve and small diameter pipe lines ... even objects which should not be in sewage (plastic, rubber, fiber, wood, etc.). The 11/4 inch discharge connection can be adapted to any piping materials which meets local code requirements. A corrosion resistant tank of fiberglass reinforced polyester (FRP), sized on the basis of computer studies of wastewater usage patterns, provides "peak flow" holding capacity. An integral check valve assembly in the GP is custom designed for non -clog, trouble -free operation. The GP is automatically activated and, because it runs infrequently and for very short periods, it's annual electric energy consumption is typically only half that of a black and white TV. It is available with an integral fiberglass accessway for burial ranges from 14 inches to 10 feet. Series 1 MODEL GP210 Series 6 GRINDER PUMP* MODEL FARRELL 210 GENERAL APPLICATIONS Its size, efficiency and operating economy make the GP 210 ideal for single dwellings, waterfront property, subdivision developments and marinas. It Is Ideally suited for new or existing communities. (U0 9 S * * Underwriters National Certified by Laboratories Sanitation Canadian Standards Ins. Foundation Ataeciation-- OPERATIONAL INFORMATION Motors: 1 HP, 1725 rpm, high torque, capacitor start, thermally protected, 240 volts 60 hertz, 8 amp, 1 phase Inlet Connections: 4" PVC closet flange standard. Can be used with other piping sizes and materials using standard adapters Discharge Connections: Pump discharge terminates in I % Inch NPT male thread. Can easily be adapted to 1 % inch PVC pipe or any other material required by local codes. Normal Peak Design Pressure: 40 psig (92 ft Head) Discharge. t 15 gpm at 0 psig 11 gpm at 40 psig Overload Capacity: Able to handle temporary peak pressure to 50 psig with no noticeable drop in output. Flow does not drop to zero or "shut off" as centrifugal pumps do. Maximum pressure which pump can generate Is limited by motor characteristics to a value well below the rating of piping and appurtenances. Automatic reset feature does not require manual operation following overload. -U.S. i Foreign Patents Issued & Pending 1Discharge Data Includes Las Through Check Valve which is Minimal --CSA certification applies only to Grinder Pumps bearing the prefix "C' In the model number. envi ron mend one CORPORATION PROTECTING MAN'S ENVIRONMENT 2773 Salltown Road - Schenectady. New York 12309 fMorder No. GP-14/1 Copyright • environment I one Printed In U.S.A. Paorder tie. GP-14/1A (1-81) eore.�+ or environment Lone GRINDER PUMP TYPICAL PERFORMANCE CHARACTERISTICS '���tt6di�iD31' �A1D1k1'i'��,r3$ 13n xsrl�x'Erii AINNEIteS:llf990t eeF�� r"- im� «�Rx1�+lii:'e "18 y�je!��{F'e�y Fsfii ?� 7a1"' i'sq�! q �v `:lq p • 14 !--��i'ie�r�iT�3++'ti�itRfS3R��-R�,'-��Ik.�f Mel09 J ;iru7 t�r7 C�gA QQ lllG� El MOM' t' . F I Mar U L . O O DISCHARGE t Q -gpm ) AND (I) AMPS AT 240 VAC 1 •sig • 2.307 feel of .+me GRINDER PUMPMODEL GP 210 29.5 ALARM LEAD GRINDER PUMP CORE 120 INLET--- • I 4"PVC SOCKET ELECTRICAL WIRING 1110FOR SOLVENT WELD (NOTES 2 6 6) (NOTES I a 4) 100PUMP CONTROL ACCESS COVER • POWER LEAD eo SEE NOTE 5 I 80 O N 70 (9)TAMPER PROOF W COVER SCREW PUMP CORE MOUNTING BOLT STAINLESS STEEL STAINLESS STEEL (12) z 60 O W = HIGH LEVEL ALARM s0 i INDICATOR LAMP c SEE NOTE 7 40 /DISCHARGE FITTING 30 1- 1/4 MPT INLET 0 ALARM 1Ul o--� I � 36.5 27.0 I I I I SEE NOTE 3 ON -T 33.0 1 AL 16.0 T I OFF 12.0 LEVEL SENSING BELL NOTES: 1. Can be adapted to any system of DWV piping dictated by local codes including cast iron, copper and non- metallics. 2. Use Fittings appropriate for wiring material which should be per applicable codes. All fittings must be water -tight. 3. Exact turn -on level depends on in -flow rate during time delay interval after pressure switch closes. 4. Interior of tank (wet well) is vented through inlet drainage piping per installation instructions. 5. Cover is suitably gasketed and bolted in order to make weather tight. 6 Ten feet of type OF cable, prewired and connected with water -tight wiring connections, is provided for both power and signal connections. Other lengths of materials available on special order. See note 2. MOTOR SEE NOTE 8 CHECK VALVE AND ANTI- SIPHON VALVE TANK J � FIBERGLASS REINFORCED POLYESTER ( F R P ) PUMP SEE PUMP CURVE PERFORMANCE CHARACTERISTICS GRINDER ALL CUTTING ELEMENTS ARE HARDENED STAINLESS STEEL ALLOY UPFLOW INTO GRINDER 7. High level alarm indicator lamp assembly furnished on wall plate 23/4 x 41h inches. Fits standard wall box (by others). Install at most obvious location on premises and connect per wiring diagram in installation instructions. Audible alarm (not furnished) may be paralleled with circuit. Lamp signal circuit contact rating is 15 amp at 120 vac. 6. One horsepower, single phase, capacitor -start, induction motor with integral automatic reset thermal overload protection. 240 volt, 60 hertz. 9. All dimensions are in inches. Do not scale drawing. 10. Specifications and drawings are subject to change without notice. environment I one CORPORATION PROTECTING MAN'S ENVIRONMENT 2773 Balllown Road • Schenectady. New York 12309 9 eerATuro ACcru01 v FR P - FIBERGLASS REINFORCED POLYESTER environment i one CORIMATION INLET - STANDARD 4" SOCKET FOR SOLVENT WELDING PVC PIPE (4.50 O. D. NOMINAL) FRP* TANK WATERTIGHT JOINT ( FABRICATED BY MFR GRINDER PUMP CORE ELECTRICAL ALARM LE..,, 10 FT LG 14-2 W/GND OF CABLE CORE LIFTING EYE (2) 10 FT LG 12-2 W/GND OF CABLE NOTES: 1. ALL DIMENSIONS IN INCHES UNLESS SPECIFIED OTHERWISE . 2. DO NOT SCALE DRAWING. 3- ALL DIMENSIONS AND SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 4. ALL FRP4 PARTS TO BE AVOCADO GREEN. 5. FACTORY ASSEMBLED AND TESTED. Model 210 Seri4s 1 B-2021 B- 227 REV C 1-85 10 COUNTY of FREDERICK Department of Public Works 540/665-5643 FAX: 540/ 678-0682 May 29, 2003 Mr. David E. Lellock, P.E. Urban Engineering and Associates, Inc. 600 Pegasus Court Winchester, Virginia 22602 RE: Subdivision Plan Comments - The Summit, Section 5B Frederick County, Virginia Dear Mr. Lellock: Upon review of the subject subdivision plan, we offer the following comments: 1) It will be necessary to submit an engineered grading plan at the time of the building permit application process for the following lots: 1226 - 1247 and 1205 - 1214. The subject site plans should entail basement and finished floor elevations, proposed grading, driveway location and culvert sizes. It will be necessary to submit a certified as -built to the public works department prior to obtaining a final certificate of occupancy. This certified as -built shall indicate finished floor elevations as well as pertinent drainage features and verify that the final lot grading conditions and building elevations meet the intent of the approved site grading plan. 2) In accordance with VESCH Standard 3.18, provide outlet protection dimensions on the plan for all proposed culverts located under Waterside Lane. In addition, it will be necessary to provide a stabilized outfall channel from the culverts to the water surface of the lake. The channel shall be designed for a ten (10) - year storm event (i.e., quantity and velocity). 3) It will be necessary to submit a certified as -built plan to this office which reflects all improvements performed along Waterside Lane. 107 North Kent Street • Winchester, Virginia 22601-5000 Subdivision Plan Comments - The Summit, Section 5B Page 2 May 29, 2003 Once these comments have been addressed, submit two (2) copies of the subdivision plan for further review. Sincerely, Joe C. Wilder Civil Engineer JCW/rls cc: Patrick Davenport, Zoning and Subdivision Administrator file A:\suinmifsec5B.wpd JOB #: 03.043- PRINT TICKET #: 0 Z Urban Engineering & Associates, Inc. 600 PEGASUS COURT #101 Telephone: (540) 450-0211 WINCHESTER, VIRGINIA 22602 Facsimile: (540) 450-0210 TO: cn�.,.�,y� k DATE: 413yl u 1 O-1 toOA} ' �VI • nc h,� fie,- % V A ATTENTION:�Q'��`^�l`�P RE: S�^�^+•,',, s Sys C�-'�Ls„ r C,oP ti TRANSMITTED HEREWITH: ORIGINALS ❑ PHOTOCOPIES ❑ CD ❑ BLACKLINE PRINTS ❑ SPECIFICATIONS ❑ COMPUTATIONS ❑ INVOICE ❑ MYLAR PRINTS ❑ COLOR PRINTS ❑ SITE NOTICES ❑ OTHER QUANTITY DRAWING NO. DATE DESCRIPTION 1 PR Z'onzy &)/o1. FOR: ❑ APPROVAL ❑ FIELD USE SENT BY. ❑ FIRST CLASS MAIL PLEASE: ❑ RETURN COMMENTS: ❑ RESUBMISSION YOUR FILES XOUR MESSENGER ❑ PICKUP ❑ SUBMIT ❑ COMMENTS ❑ OTHER ❑ COURIER ❑ OVERNIGHT ❑ OTHER i S o S a tpurr�tS Cp -VO' 0111 i�c�ca--1�S C,I-21 -Tize- OEM DT: SUBDIVISION FILE SUMMIT, SECTION 5 SUB DIVISION ... . . . . . . . . . . . . .