Loading...
HomeMy WebLinkAbout15-07 Senseny Village Ph I Red Bud 43 Lots 17.19 Acres - BackfileSUBDIVISION CHECKLIST 1. Comment sheets from the following agencies, along with any marked copies of the plan: VDOT City of Winchester 1/ GIS Sanitation Authority Health Department ✓ sc h �' c; l Inspections Department Parks & Recreation `/ Fire Marshall County Engineer 2. One copy of the subdivision application TRACKING SHEET Date To be filled in if an MDP is associated with this subdivision MDP# /A -66 Approved by BOS: Admin. Approval: l 11-7� c�lo-7 Application received 0 Fee paid (Amount: $ d0 /,k� 43" 1 Information entered in d-BASE and Reference Manual 10 I b Jam, File given to Renee' to add to Application Action Summary Plat(s) signed by Subdivision Administrator Approval letter to applicant/agent Copy of final subdivision plat(s) [with signatures] made and given to Mapping and Graphics Manager for structure numbering assignment Updated d-BASE and Reference Manual File given to Renee' to update Application Action Summary Final plat(s) submitted with review agency signatures along with: Recorded Deed of Dedication Bond estimate (if required) $_ 4-4 o ro � N mLO O cr wa�3 Page 1 of 2 Lauren Krempa From: Jeremy Tweedie Utweedie@greenwayeng.com] Sent: Thursday, November 15, 2007 1:24 PM To: Lauren Krempa Subject: RE: Senseny Village Attachments: 3924- FCPW - Revised Site Plan Comments - 062807.pdf; 3924- Senseny Village - FC Fire Marshall Phase 1 Comments - 112206.pdf; 3924- Senseny Village - FCPRD Conditional Subdivision Comments - 120606.pdf; 3924- Senseny Village - FC GIS Conditional Subdivision Comments - Phase I - 112206.pdf; 3924 - FC Inspections - Conditional Subdivision comments - 1-5-07.pdf; 3924- FCPS - Senseny Village Phase 1 - 011707.pdf Will get you FCSA, I have to find it. Do you also want me to send paper copies, not a problem, let me know Thanks -Jeremy From: Lauren Krempa [mailto:lkrempa@co.frederick.va.us] Sent: Thursday, November 15, 2007 1:12 PM To: Jeremy Tweedie Subject: RE: Senseny Village We need at least 5 sets for final approval. As for agencies, all I have now is Public Works. So I'll need them from: VDOT Schools FCSA Fire Marshall Inspections GIS And that's it O Thanks O Lauren Lauren E. Krempa Planner I Department of Planning & Development Frederick County 107 N. Kent Street, Suite 202 (54o)665-5651 From: Jeremy Tweedie[mailto:jtweedie@greenwayeng.com] Sent: Thursday, November 15, 2007 1:03 PM To: Lauren Krempa Subject: RE: Senseny Village We just received VDOT approval, I believe you have all the rest if no let me know and I will send the missing 11/19/2007 lu el 1105 Pr`'vv� 7 fvt � Page 2 of 2 approvals to you. How many sets do you require for signature. Please advise Jeremy From: Lauren Krempa[mailto:lkrempa@co.frederick.va.us] Sent: Thursday, November 15, 2007 12:55 PM To: Jeremy Tweedie Subject: Senseny Village Jeremy — I'm just checking in on Senseny Village as we get closer to the holiday season. Last time we talked, the plan still needed agency approvals. Just making sure that that is still the case? Let me know! Thanks! Lauren Lauren E. Krempa Planner I Department of Planning & Development Frederick County 107 N. Kent Street, Suite 202 (54o)665-5651 11 /19/2007 Page 1 of 1 Lauren Krempa From: Jeremy Tweedie Utweedie@greenwayeng.com] Sent: Tuesday, October 09, 2007 10:45 AM To: Lauren Krempa Subject: RE: Senseny Village no, thank you!I will incorporate additional note ASAP Thanks again From: Lauren Krempa [mailto:lkrempa@co.frederick.va.us] Sent: Tuesday, October 09, 2007 10:43 AM To: Jeremy Tweedie Subject: Senseny Village Jeremy — per our conversation just now please add the following sentence to the existing cover sheet landscaping note: "The proffered tree save area is not counted towards the required landscaping for this development." Thanks for you help! Lauren Lauren E. Krempa Planner I Department of Planning & Development Frederick County 107 N. Kent Street, Suite 202 (540)665-5651 11 /19/2007 GREENWAY ENGINEERING`,' 151 Windy Hill Lane Founded in 1971 Winchester, Virginia 22602 TRANSMITTAL Project Name: Senseny Village File No: 3924 Date: Wed, Oct 3, 2007 To: FC Planning Attn: Lauren E. Krempa Copied Delivery: r Fed Ex Other_ U.S. Mail From: Bob Beavin GREENWAY ENGINEERING Phone: 540-662-4185 Fax: 540-722-9528 Fj Courier j`j Pick Up 3 F1 Urgent rv-1 For Your Review r-1 As You Requested r-1 Please Comment Message Lauren: We believe that the attached materials, 2 sets of revised plans for Senseny Village - Phase I, and a Comment Response Letter addressing your comments of August 15, 2007, duplicate the materials Jeremy Tweedie sent to you recently. Please advise if these are not the right materials. Thanks. Hand Delivery and Pick Ups Only: Received by: Date: Please Print Name: 1*61 FC Ps' Frederick County Public Schools Coordinator of Construction Visit us at www_frederick.k12.va.us e-email: and Facilities Use kapocsis@frederick.k12.va.us January 15, 2007 Mr. Jeremy Tweedie Greenway Engineering 151 Windy Hill Lane Winchester, VA 22602 Dear Mr. Tweedie: RE: Senseny Village Phase I This letter is in response to your request for conditional subdivision comments for the proposed Senseny Village Phase I project. Based on the information provided, it is anticipated that the proposed 43 single-family homes in Phase I will yield (using the current model) 7 high school students, 6 middle school students, and 10 elementary school students for a total of 23 new students upon build -out of Phase 1. Significant residential growth in Frederick County has resulted in the schools serving this area having student enrollments nearing or exceeding the practical capacity for a school. The cumulative impact of this project and others of similar nature, coupled with the number of approved, undeveloped residential lots in the area, will necessitate the future construction of new schools facilities to accommodate increased student enrollments. The impact of this request on current and future school needs should be considered during the approval process. Respectfully yours, )ephcnM. Kapocsi Coordinator of Construction and Facilities Use n� SMK:dkr cc: Patricia Taylor, Superintendent of Schools "1 .IAN X 7 20117 Y Pe � I.; At Omdorff, Assistant Superintendent for Administration �� y ,ram Charles Puglisi, Director of Transportation gYLPQ 15 " 540-662-4518 Ext 88112 1415 Amherst Street, Post Office Box 3508, Winchester, VA 22604-2546 FAX 540-662-3890 Dwellings shall comply with The Virginia Uniform Statewide Building Code and The international Residential 2003 Codes. Please resubmit site grading elevations fos each lot. Also include lowest floor elevation. Backwater valves shall be installed on all plumbing fixtures, (subject to back sewer), located below the top elevation of the upstream man hole cover. REQUEST FOR CONDITIONAL SUBIDVISION COMMENTS Frederick County inspections Department ATTN: Building Official 107 North Kent Street Winchester, Virginia 22601 (540)665-6350 The Frederick County Inspections Department is located at 107 North Kent Street, 4th Floor of the County Administration Building in Winchester, if you prefer to hand deliver this review. Applicant's name, address and phone number: Greenway Engineering 151 Windy Hill Lane Winchester, VA 22602 662-4185 Name of development and/or description of the request: Senseny Village Phase I - 43 Lots Location: South of Rossum Lane (Route 736) and Twinbrook Circle (Route 867) of the Senseny Road Corridor Inspection Department Comments: Code Administrator Signature and Date: (NOTICE TO INSPECTIONS DEPT. x ET ASE RURN THIS J TO NOTICE TO APPLICANT It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Also, please attach a copy of your application form, location map and all other pertinent information. JAN 0 5 2007 I L'+ U s jai REQUEST FOR CONDITIONAL SUBDIVISION COMMENTS Frederick County Department of GIS Attn: Marcus Lemasters, GIS Manager 107 North Kent Street Winchester, Va. 22601 (540)665-5651 The GIS Manager will review the proposed street names for this project to ensure their acceptability into the Frederick County Street Name System. Proposed street names will also be routed through the Communication Center Supervisor for review. This step will prevent duplicate street names from being entered. Please attach one copy of the plan indicating proposed names. Applicant's name, address and phone number: Greenway Engineering 151 Windy Hill Lane, Winchester, VA 22602 540-662-4185 Name of development and/or description of the request: Senseny Village Phase I - 43 Lots Location: South of Rossum Lane (Route 736) and Twinbrook Circle (Route 867) of the Senseny Road Corridor GIS Department Comments: er p C F Tt T ''� Nov 2 2 MIS ey�i REQUEST FOR CONDITIONAL SUBIDVISION COMMENTS Frederick County Parks and Recreation Dept. Attn: Director of Parks and Recreation 107 North Kent Street Winchester, Va. 22601 (540) 665.5678 The Frederick County Parks and Recreation Department is located on the second floor of the Frederick County Administration Building, 107, North Kent Street, Winchester, if you prefer to hand deliver this review form. i - If Applicant's name, address and phone number: Greenway Engineering 151 Windy Hill Lane_ Winchester, VA 22602 662-4185 Name of development and/or description of the request: Senseny Village Phase I - 43 Lots Location: South of Rossum Lane (Route 736) and Twinbrook Circle (Route 867) of the Senseny Road Corridor Parks and Recreation Department Comments: Plan appears to meet open space requirements. Parks Signature and Date: O (NOTICE TO PARKS *PLEAA RETURN THIS FORM TO NOTICE TO APPLICANT It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Also, please attach a copy of your application form, location map and all other pertinent information. DEC 0 6 Z006 r 6y CIZ�i ��.� *,CW O Frederick County Fire and Rescue o� Department Office of the Fire Marshal Plan Review and Comments Control number Date received Date reviewed Date Revised SD06-0011 11/172006 11212006 Project Name Applicant Senseny Village- Phase 1 Geenway Engineering Address City State Zip Applicant Phone 151 Windy Hill Ln. Winchester VA 22602 540-662A165 Type Application Tax ID Number Fire District Subdivision 65-A49B, 55 18 Current Zoning RP R d Automatic Sprinkler System No Other recommendation Emergency Vehicle Access Adequate Siamese Location Not Identified Emergency Vehicle Access Comments Access Comments Additional Comments ecommen ations Automatic Fire Alarm System No Requirements Hydrant Location Adequate Roadway/Aisleway Width Adequate Rescue District 18 Election District Red Bud Residential Sprinkler System Yes Fire Lane Required Yes Special Hazards No � 2 1 70PR �� I uLl t�ov LBy— Plan Approval Recommended Reviewed By Signature y / Yes Jeffrey S. Neal C� Title *tcx Frederick County Fire and Rescue • °� Department Office of the Fire Marshal Plan Review and Comments Control number Date received Date reviewed Date Revised SD06-0011 11/172006 11212006 Project Name Applicant Senseny Village- Phase 1 Geenway Engineering Address City State Zip Applicant Phone 151 Windy Hill Ln, Winchester VA 22602 540-6624165 Type Application Tax ID Number Fire District Subdivision 65•A-49B, 55 18 Current Zoning RP Automatic Sprinkler System No other recommendation Emergency Vehicle Access Adequate Siamese Location Not Identified Emergency Vehicle Access Comments Access Comments Additional Comments P � iz - r Gmlt ed. ecommen a ions Automatic Fire Alarm System No Requirements Hydrant Location Adequate Roadway/Aisleway Width Adequate Rescue District 16 Election District Red Bud Residential Sprinkler System Yes Fire Lane Required Yes Special Hazards No Fnc 1uLf NOV 2 1790G III LBY-.� Plan Approval Recommended Reviewed By Signature Yes Jeffrey S. Neal TWO /JN GREENWAY ENGINEERING, INC. %47 151 Windy Hill Lane Winchester, Virginia 22602 Founded in 1971 September 20, 2007 Frederick County Department of Planning and Development 107 North Kent Street, Suite 202 Winchester, VA 22601 Attn: Lauren E. Krempa, Planner I Re: Senseny Village Subdivision Comment Response Letter Dear Ms. Perkins: We are in receipt of your comments dated August 15, 2007, and offer the following comments: Comments from Frederick County Department of Planning and Development: dzi Comment 1: On Sheet 1 of 26, please revise the note on the cover sheet to match the note on the MDP regarding the landscaping options/requirements. The note still references the tree save area as the landscaping option. Response: Revised as noted. Refer to sheet 1. Comment 2: On Sheet 9 of 26, regarding signage, the note regarding the signage easements for this development appears to be missing and should not reference the Frederick County Planning Commission. Instead, provide a generalized note ensuring that any signs will comply with Section 165-30 of the Frederick County Zoning Ordinance. Response: Revised as noted. Refer to sheet 1. Comment 3: On Sheet 9 of 26, the label regarding the ten foot no disturb area was not provided. Response: Revised as noted. Refer to sheet 9, 10, 11. Comment 4: On Sheet 26 of 26, provide a calculation for the number of street trees atone tree per 40 feet of road frontage and ensure that each lot has two trees. On lots that are narrower, it is appropriate to place the second tree on the rear of these lots. The pipestem lot also requires two trees per lot. Response: Additional trees were added to conform to county requirements. Refer to sheet 26. Engineers Surveyors Telephone 540-662-4185 FAX 540-722-9528 File #3924/JT/reb www.greenwayeng.com Comment 5: On Sheet 26 of 26, there appears to be several large gaps in the street trees in areas where open space fronts on the roads. Provide trees at the one tree to 40 feet of frontage ration in these areas. Response: Additional trees were added to conform to county requirement. Please note that areas were gaps are noticed are due to the topographical features and is impractical to landscape and maintain. Refer to sheet 26. Thank you for your assistance with this project. Contact us with any questions or need for additional information. Sincerely, Greenway En ineering Jeremy Tweedie File 3924/JT/reb GREENWAY ENGINEERING, mc. 151 Windy Hill Lane Winchester, Virginia 22602 Founded in 1971 September 20, 2007 Frederick County Department of Planning and Development 107 North Kent Street, Suite 202 Winchester, VA 22601 Attn: Lauren E. Krempa, Planner I Re: Senseny Village Subdivision Comment Response Letter Dear Ms. Perkins: We are in receipt of your comments dated August 15, 2007, and offer the following comments: Comments from Frederick County Department of Planning and Development: Comment 1: On Sheet 1 of 26, please revise the note on the cover sheet to match the note on the MDP regarding the landscaping options/requirements. The note still references the tree save area as the landscaping option. Response: Revised as noted. Refer to sheet 1. Comment 2: On Sheet 9 of 26, regarding signage, the note regarding the signage easements for this development appears to be missing and should not reference the Frederick County Planning Commission. Instead, provide a generalized note ensuring that any signs will comply with Section 165-30 of the Frederick County Zoning Ordinance. Response: Revised as noted. Refer to sheet 1. Comment 3: On Sheet 9 of 26, the label regarding the ten foot no disturb area was not provided. Response: Revised as noted. Refer to sheet 9, 10, 11. Comment 4: On Sheet 26 of 26, provide a calculation for the number of street trees atone tree per 40 feet of road frontage and ensure that each lot has two trees. On lots that are narrower, it is appropriate to place the second tree on the rear of these lots. The pipestem lot also requires two trees per lot. Response: Additional trees were added to conform to county requirements. Refer to sheet 26. Engineers Surveyors Telephone 540-662-4185 FAX 540-722-9528 File #3924/1T/reb www.greenwayeng.com Comment 5: On Sheet 26 of 26, there appears to be several large gaps in the street trees in areas where open space fronts on the roads. Provide trees at the one tree to 40 feet of frontage ration in these areas. Response: Additional trees were added to conform to county requirement. Please note that areas were gaps are noticed are due to the topographical features and is impractical to landscape and maintain. Refer to sheet 26. Thank you for your assistance with this project. Contact us with any questions or need for additional information. Sincerely, Greenway En:ring Jeremy Tweedie File 3924/JT/reb August 15, 2007 Greenway Engineering Attn: Jeremy Tweedie 151 Windy Hill Lane Winchester, VA 22602 RE: Senseny Village Subdivision Numbers (PINs): 64-A-49B Performance); 2°d Review Dear Jeremy: co ICK Department of ning and Development 540/665-5651 FAX: 540/ 665-6395 Design Plan Review; Property Identification and 64-A-50; Zoning District: RP (Residential I have had the opportunity to re -review the Subdivision Design Plan (SDP) for Senseny Village, changes to which were submitted to this office on July 30, 2007. At this time, administrative approval cannot be granted. This plan is denied until the issues in this letter, as well as all issues of the other review agencies, have been adequately addressed. Please address the following comments, questions, or concerns: I. On Sheet Iof 26, please revise the note on the cover sheet to match the note on the MDP regarding the landscaping options/requirements. The note still references the tree save area as the landscaping option. 2. On Sheet 9 of 26, regarding signage, the note regarding the signage easements for this development appears to be missing and should not reference the Frederick County Planning Commission. Instead, provide a generalized note ensuring that any signs will comply with Section 165-30 of the Frederick County Zoning Ordinance. 3. On Sheet 9 of 26, the label regarding the ten foot no disturb area was not provided. 4. On Sheet 26 of 26, provide a calculation for the number of street trees at one tree per 40 feet of road frontage and ensure that each lot has two trees. On lots that are narrower, it is appropriate to place the second tree on the rear of these lots. The pipestem lot also requires two trees per lot. 5. On sheet 26 of 26, there appears to be several large gaps in the street trees in areas where open space fronts on the roads. Provide trees at the one tree to 40 feet of frontage ratio in these areas. 107 North Kent Street, Suite 202 • Winchester, Virginia 22601-5000 Jeremy Tweedie Re: Senseny Village Subdivision August 15, 2007 Page 2 Please address the above comments and resubmit. Since only one copy of the revised plan was provided, I am unable to include a marked set to assist you with the review; however, I am more than happy to meet with you to go over the marked set if need be. If you have any other questions, please feel free to call me at 540-665-5651. Sincerely, _ r . i N.. Lauren E. Krempa Planner I LEK/bad cc: Quinnelly Group, LLC, 22A Ricketts Drive, Winchester, VA 22601 %447 Founded in 1971 GREENWAY ENGINEERING, mc. 151 Windy Hill Lane Winchester, Virginia 22602 July 30, 2007 County of Frederick Department of Planning and Development 107 North Kent Street, Suite 202 Winchester, VA 22601 Attn: Lauren E. Krempa, Planning Technician Re: Senseny Village Subdivision Design Plan Comment Response Letter Dear Ms. Krempa: We are in receipt of comments from Frederick County Planning and Development dated June 29, 2007, and offer the following responses: (}C{oommje�nts from Frederick County Planning and Development: V l� Com00 m6t o ent 1: On Le4, regarding landscaping, the approved Master Development Plan (MDP) for this project requires a combination of either the street tree or ornamental landscaping option. The proffered tree save area may not be used to meet the landscaping requirements of the Zoning Ordinance. Revise the note on the cover sheet of this plan and provide a landscaping plan (page 25) which satisfies the approved MDP. I Response: Street landscaping has been provided as requested. Refer to sheet 26. C i'l? C YDV I wCC Comment 2: On sheet 1 of 24, provide a note or chart regarding the number of pipestem lots per phase on the cover sheet. The number of pipestem lots is not to exceed five percent of the total lots for the development. Response: A note is now shown on cover sheet for the pipe -stem lot. Cenunrnr—P On sheet I of 24, all single family detached references should read single family detached cluster. Revise the cover sheet as indicated on the plan. Response: The "cluster" has been added as indicated. f Gent-4.-- On sheet I of 24, Rossum Lane is misspelled. Response: Corrected. f �On sheet I of 24, the minimum lot widths for the Single Family Detached Cluster housing type are 60 feet at the setback and 30 feet at the rig of way. Response: Minimum setbacks corrected as indicated. Engineers Surveyors Telephone 540-662-4185 FAX 540-722-9528 File #400020/SW/reb/mah www.greenwayeng.com Xaui&nr6-_ On sheet 1 of 24, provide a note on the cover sheet referencing,the disturbance of lands on the property. Response: �s is indicated in the Total Overall Environmental Features Tabulation on the cover sheet. nt : On sheets 9, 10, and 11 of 24, regarding street lights, the number of street lights throughout the development appears to be insufficient. Frederick County's subdivision ordinance requires adequate type and intensity of street lights to promote general health and safety, consider placement of additional lights as shown on the plan. Response: Additional Lights added in proximity indicated on plan. "'_ On sheets 9, 10, and 11 of 24, label the proffered tree save area within the open spaces. Response: Open space areas now labeled., -- -sheet 9 of 24, regarding signage, show the location of any proposed subdivision entrance signs and any necessary sign easements for the development. Response: No entrance f ture planned by the developer thus far. A note has been added to Cover �G sheet indicating that easement must be obtained from the Frederick County Planning i Commission. Comment 10: On Sheet 9 of 24, label the ten foot no disturb easement, as shown on the MDP, per proffer B3 from the rezoning for this property. nn 11 "U Response: The label has been added as indicated. 1: On Sheet 9 of 24, regarding sidewalks, provide sidewalks on both sides of Rossum ane Extension (proposed) and continue the sidewalks to the property line. Also show any sidewalks on existing Rossum Lane. vv T� tense: Only one sidewalk remains with existing sidewalk shown connecting. . n sheet 9 of 24, label the open space parcel with acreage. n Space labels added with acreage/square feet. Comment 13: On sheet 9 of 24, provide the total right -of- way for Rossum Lane extension Vf'por.ptreets sed) and move the label so that it is visible as shown on the plan. Provide any speed limits within the subdivision. Also, provide the right-qf-way for all existing roads on the plan. Response: Proposed R.O.W. width added with mph. Ex. R.O.W. width added to Rossum Lane. Comment 14: On sheet 9 of 24, remove the "10 BRL" label from the easement on lot 36. Response: Label Removed. r\_0 F---, File #400020/S W/reb/mah Com ent 15: On sheet 9 of 24, provide a stop bar for the stop sign located on Lehigh Drive (pr posed) as indicated on the plan. esponse: Stop Bar provided. Comm t 16: On sheets 9 and 10 of 24, show the phase line and label lots in future phases as such. sponse: Lots Labeled, see sheet 2 for phase lines. Comm nt 17: On sheet IO of 24, label the open space parcel with acreage. ponse: Open Space labeled. Comment 18: On sheet 11 of 24, provide the traffic calmer on Lehigh Drive (proposed) as shown on the DP. ponse: A traffic calmer was added at station 12+88. Commen 19: On sheet 11 of 24, the approved MDP shows a temporary cul-de-sac at the end of U rive. Show the temporary cul-de-sac on the plan. : An alternate turnaround is provided (Branch Type) per VDOT subdivision Design pendix B Figure4. See Attachment. Comment 0: On sheet 15 of 24, provide a typical cross section detail for the Rossum Lane Lsensio . nse: The cross section has been added omI nt 21: On sheet 23 of 24, provide the traffic calmer detail as mentioned on sheet 9 of 24. ponse: Detail provided. Comme 22: On sheet 23 of 24, provide details of all traffic signs. R p nse: A sign table has been added to sheet 24 Comment : On sheet 24 of 24, Senseny is misspelled. R se: Spelling Corrected. Thank you for your assistance with this project. Contact us with any questions or need for additional information. Sincerely, Greenway Engineering Jeremy Tweedie, Project Manager cc: Quinnelly Group, LLC? File #400020/S W/reb/mah a GREENWAY ENGINEERING 151 Windy Hill Lane Founded in 1971 Winchester, Virginia 22602 TRANSMITTAL Project Name: Senseny Village Phase I File No: 3924 Date: 7-31-07 To: FC Planning From: Jeremy Tweedie/aks Attn: Lauren Krampa- Planning Tech GREENWAY ENGINEERING Copied Phone: 540-662-4185 Fax: 540-722-9528 Delivery: ❑ Fed Ex ❑ U.S. Mail 0 Courier [] Pick Up Other ❑ Urgent Fv�o For Your Review ❑ As You Requested ❑ Please Comment Message Lauren Attached is the following for the above reference project for your review and approval. 1 copy of the revised plan per your comments Thank you for your assistance. If you have any questions, please feel free to give us a call Hand Delivery and Pick Ups Only: Received by: Date: Please Print Name: From: Funkhouser, Rhonda [mailto:Rhonda.Funkhouser@VDOT.Virginia.gov] On Behalf Of Ingram, Lloyd Sent: Friday, August 03, 2007 7:12 AM To: Jeremy Tweedie Cc: Ingram, Lloyd; Baluch, Stephen; Eric Lawrence Subject: Senseny Village Road Improvement Plan/Rossum Lane - VDOT Conditional Approval This is to acknowledge receipt of your revised plans dated June 14, 2007 for the referenced project. The plans appear satisfactory and are approved subject to correction of the following items. If for any reason you cannot accommodate any of these items, please call to discuss before submitting the final plan sets for VDOT distribution. 1. On sheet 5, show STOP lines (24" wide white thermoplastic) at street connections with Senseny Road. 2. On sheet 5, change CG-7 along Senseny Road to CG-6. This is based on the geometric design standards for Urban Collector (GS-7), VDOT Road Design Manual, p. A-11, Rev. 7/07, http_J/www.extranet.vdot.state.va. us/locdes/Electronic%20 Pubs)'2005%20RDMLa ppenda.pdf . 3. On sheet 5 at the intersection of Rossum Lane and Senseny Road, the sidewalk should terminate with a CG-12B curb ramp in the curb return radius. Add a CG-12B curb ramp on the opposite side of Rossum Lane as well. 4. On sheet 5 at the intersection of Twinbrook Circle and Senseny Road, add CG-12 curb ramps in the curb return radius on both sides of Twinbrook Circle. 5. On sheet 5 in the "Typical Section' for the Senseny Road turn lanes, change the note about'Match existing cross slope' to Required cross slope 1/a" foot'. Add an additional note: `Use VDOT detail WP-2 for tie in to existing pavement. Mill and overlay existing pavement as needed to provide required cross slope. Pave to squared ends of tapers where it will not interfere with drainage. Verify requirements with the VDOT inspector.' 6. On sheet 5 in the Construction Notes', add a note as follows: 'Use VDOT standard PM-3 for pavement markings details for unsignalized intersection.' 7. On sheet 10, include the latest modifications to the Rossum Lane plans as provided with your July 18, 2007 email to Mr. Stephen Baluch. 8. On sheet 10, the plans for proposed lighting along Rossum Lane, located on the roadway ROW, has been forwarded to the VDOT Staunton District for review. The comments/approval for the lighting will be covered in a separate letter. 9. On sheet 10, in the Notes' for Rossum Lane improvements, add a note that driveways shall use the special details on sheet 13, and remove VDOT details CG-9B and CG-9D from sheet 12. 10. On sheet 13 in the profile for Twinbrook Cir. Culvert -10, the minimum clearance between pavement and drainage pipe should be 18". Portions of the profile show cover less than 12", which will not accommodate the proposed pavement structure above the pipe. Adjust to provide minimum cover sufficient for the required pavement structure. 11. On sheet 10 (as revised and provided by email 7/18/07), for the sight lines of 280 feet at the street connections with Rossum Lane, the portions of the sight lines that extend beyond the roadway ROW will require sight distance easements. 12. On sheet 13, the previous comment about the 10-foot long transition at all curb type change locations applies to transitions between CG-6 and CG-7 (which are now eliminated by use of CG-6 on Senseny Road). The transition in the sidewalk/driveway apron detail could be based on the maximum cramp slope of 12:1 as shown on VDOT standard CG-12. 13. On sheet 14, add the following Typical Traffic Control (TTC) diagrams and notes from the Virginia Work Area Protection Manual which will be needed for traffic control during the widening of Route 657: TTC- 4.0, TTC 18.0, and TTC- 36.0. 14. Several VDOT road and bridge standard details need to be added or updated on the plans as indicated below. The VDOT website has been revised to facilitate access to the latest Road and Bridge Standards' detail sheets. See the attached email message dated 7/6/07 for a description of the changes. Standard T-DI-3,4 Add T-DI-3,4 DI-3A,3B,3C Depth (H) _ DI-3A,3B,3C Sheet Latest Rev. Title Page Notes 1 of 2 Rev. 3/03 Standard Precast Top Units 103.05 2 of 2 Standard Precast Top Units 1 of 2 Standard Curb Drop Inlet, 8 feet 104.09 Add 103.06 Add 12"-30" Pipe: Maximum 2 of 2 Standard Curb Drop Inlet, 12"-30" Pipe: Maximum Depth (H) = 8 feet 104.10 Add IC-2 3 of 3 Precast Inlet and Frame Cover 105.03 Add IS-1 Standard Method of Shaping Manhole & Inlet Inverts 106.08 Add PB-1 New 1/04 Installation of Pipe Culverts and Storm Sewers General Notes 107.00 Add PB-1 1 of 4 Rev. 7/05 Installation of Pipe Culverts and Storm Sewers Circular Pipe Bedding and Backfill — Method "A" 107.01 Add UD-4 1 of 2 Rev. 1/04 Standard Pavement Edgedrain 108.06 OK UD-4 2 of 2 Rev. 2/06 Standard Pavement Edgedrain 108.07 OK EC-1 Rev. 9/06 Stone for Erosion Control 114.01 Update on sheet 12. CG-6 Rev. 9/06 Combination 6" Curb & Gutter 201.03 Update on sheet 12. CG-11 Rev. 7/01 Method of Treatment -Connection for Street Intersections and Commercial Entrances 203.04 Update on sheet 12. CG-12 1 of 4 Rev. 7/05 CG-12 Detectable Warning Surface General 203.05 Add CG-12 2 of 4 Rev. 7/05 (Perpendicular) Application CG-12 3 of 4 Rev. 7/05 (Parallel) Application 203.06 CG-12 4 of 4 Rev. 7/05 & Perpendicular) Application WP-2 New 9/06 CG-12 Detectable Warning Surface Type A 203.05A Add (not req'd if no Type A.) CG-12 Detectable Warning Surface Type B Add Notes CG-12 Detectable Warning Surface Type C (Parallel 203.07 Add (not req'd if no Type C.) Pavement Widening 303.02 Add TPT-1 New 9/06 Transverse Pavement Tie -In 305.01 Add PM-3 Typical Pavement Marking for Unsignalized Intersections 1301.88 Add MUTCD Fig. 3B-21 2003 Edition Examples of Standard Arrows for Pavement Markings p. 3B-32 Add to plans MUTCD Sec. 2B.04 2003 Edition STOP sign (R1-1) p. 2B-1, 2 Indicate sign size 30"x30" MUTCD Sec.2A.16 2A.18 2A.19 2A.20 2A.21 2003 Edition Standardization of Location, Mounting Height, Lateral Offset Orientation Posts and Mountings p. 2A-8 thru 2A-13 sheet 7. Add sign mounting height on TTC-4.0 WAPM May 2005 Stationary Operation on Shoulder (Notes & Figure) p.6H-12, 13 Add for traffic control on Route 657 and 736. TTC-18.0 WAPM May 2005 Flagging Operation on Two -Lane Road (Notes & Figure) p. 61-1-40, 41 TTC-36.0 WAPM May 2005 Signing for Project Limits (Notes & Figure) p.6H-76-77 VDOT 0647-034-223, C501 Square Tube Steel Sign Posts 16(8) Copy attached (for permanent sign supports). Please advise the developer of this conditional approval. Please provide 6 sets of approved construction plans with signed seal for VDOT distribution. I offer the following general comments: A preconstruction conference be held by the engineer and/or developer with the attendance of the contractor, various County agencies and VDOT prior to initiation of work. Materials used and method of construction shall apply to current observed VDOT Road & Bridge Specifications applicable during construction of this development. Our review and comments are general in nature. Should conditions in the field exist such that additional measures are warranted, such measures shall be completed to the satisfaction of the Department prior to inclusion into the Secondary Road System. Attached is a copy of the minimum requirements and information needed prior to acceptance of subdivision streets into the Secondary System. This is the responsibility of the developer. • All drainage is to be carried within the right-of-way in ditch lines or gutters along the street to a pipe or drainage easement. The contractor shall notify VDOT when work is to begin or cease for any undetermined length of time. VDOT will also require 48 hours notice for inspections. The appropriate land use permits shall be obtained before any work is performed on the State's right-of-way. The permit is issued by this office and will require a minimum processing fee, surety bond coverage, and the salary & expenses of a State assigned Inspector. • If mailboxes are to be placed along the roadway fronting lots, a minimum of 6" shall be between the face of curb and the front of mailbox as shown on the VDOT standard detail RFD-1. • Private entrances will be installed in accordance with special details on the plans. This is the developer's responsibility. • Any entrances constructed from the referenced street(s) shall meet VDOT minimum standards. This is the developer's responsibility. • Any signs to be installed will be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and the approved plans. • I suggest any utilities and/or storm sewer placed within the proposed right-of-way be backfilled completely with C.R. Type 21-B Stone. This will greatly reduce the possibility of any pavement settlement. • A copy of any/all recorded plats of dedication for drainage easements or additional right-of-way required for implementation of this proposed project should be provided to VDOT prior to issuance of any land use permit. Dedication should be made to the Commonwealth of Virginia. • A copy of any/all RECORDED PLATS of dedication to public use (the County of Frederick) for drainage easements or additional right-of-way required for implementation of this proposed project should be provided for VDOT review prior to issuance of any land use permit. Should you need additional information, do not hesitate to call me or Mr. Stephen Baluch in the Winchester office at 535-1829. <<SquareTubeSteelSignPosts.pdf>> <<Updated Road & Bridge Standards Website.doc>> <<Plan Approval Attachments.pdf>> JUN 2 7 COUNTY of FREDERIC` Department of Public Wor ;.< 540/665-56 FAX: 540/678-0( June 27, 2007 Mr. Jeremy Tweedie Greenway Engineering 151 Windy Hill Lane Winchester, Virginia 22602 RE: Revised Site Plan Comments - Senseny Village Phase 1 Frederick County, Virginia Dear Mr. Tweedie: Upon review of the revised site plan received June 18, 2007, all of our previous comments have been addressed. Therefore, we grant our approval of the subject site plan. Sincerely, Joe C. Wilder Deputy Director JCW/mlr cc: Planning and Development file C:\Documents and Settings\MR\My Documents\Review Formats\SENSENWILLAGEPHIAPPROVAL.wpd 107 North Kent Street - Winchester, Virginia 22601-5000 I June 29, 2007 Greenway Engineering Attn: Jeremy Tweedie 151 Windy Hill Lane Winchester, VA 22602 ERICK and Development 540/665-5651 FAX: 540/ 665-6395 RE: Senseny Village Subdivision Design Plan Review; Property Identification Numbers (PINs): 64-A-49B and 64-A-50; Zoning District: RP (Residential Performance) Dear Jeremy: I have had the opportunity to review the Subdivision Design Plan (SDP) for Senseny Village, submitted to this office on June 22, 2007. At this time, administrative approval cannot be granted. This plan is denied until the issues in this letter, as well as all issues of the other review agencies, have been adequately addressed. Please address the following comments, questions, or concerns: 1. On Sheet 1 of 24, regarding landscaping, the approved Master Development Plan (MDP) for this project requires a combination of either the street tree or ornamental landscaping option. The proffered tree save area may not be used to meet the landscaping requirements of the Zoning Ordinance. Revise the note on the cover sheet of this plan and provide a landscaping plan (page 25) which satisfies the approved MDP. 2. On sheet 1 of 24, provide a note or chart regarding the number of pipestem lots per phase on the cover sheet. The number of pipestem lots is not to exceed five percent of the total lots for the development. 3. On sheet 1 of 24, all single family detached references should read single family detached cluster. Revise the cover sheet as indicated on the plan. 4. On sheet 1 of 24, Rossum lane is misspelled. 5. On sheet 1 of 24, the minimum lot widths for the Single Family Detached Cluster housing type are 60 feet at the setback and 30 feet at the right of way. 107 North Kent Street, Suite 202 • Winchester, Virginia 22601-5000 Jeremy Tweedie Re: Senseny Village Subdivision June 29, 2007 Page 2 6. On sheet 1 of 24, provide a note on the cover sheet referencing the disturbance of wetlands on the property 7. On sheets 9, 10, and 11 of 24, regarding street lights, the number of street lights throughout the development appears to be insufficient. Frederick County's subdivision ordinance requires adequate type and intensity of street lights to promote general health and safety, consider placement of additional lights as shown on the plan. 8. On sheets 9, 10, and 11 of 24, label the proffered tree save area within the open spaces. 9. On Sheet 9 of 24, regarding signage, show the location of any proposed subdivision entrance signs and any necessary sign easements for the development. 10. On Sheet 9 of 24, label the ten foot no disturb easement, as shown on the MDP, per proffer B3 from the rezoning for this property. 11. On sheet 9 of 24, regarding sidewalks, provide sidewalks on both sides of Rossum Lane extension (proposed) and continue the sidewalks to the property line. Also, show any sidewalks on existing Rossum Lane. 12. On sheet 9 of 24, label the open space parcel with acreage. 13. On sheet 9 of 24, provide the total right-of-way for Rossum Lane extension (proposed) and move the label so that it is visible as shown on the plan. Provide any speed limits for streets within the subdivision. Also, provide the right-of-way for all existing roads on the plan. 14. On sheet 9 of 24, remove the "10 BRL" label from the easement. on lot 36. 15. On sheet 9 of 24, provide a stop bar for the stop sign located. on Lehigh Drive (proposed) as indicated on the plan. 16. On sheets 9 and 10 of 24, show the phase line and label lots in future phases as such. 17. On sheet 10 of 24, label the open space parcel with acreage. 18. On sheet 11 of 24, provide the traffic calmer on Lehigh Drive (proposed) as shown on the MDP. Jeremy Tweedie Re: Senseny Village Subdivision June 29, 2007 Page 3 19. On sheet 11 of 24, the approved MDP shows a temporary cul-de-sac at the end of Lehigh Drive. Show the temporary cul-de-sac on the plan. 20. On sheet 15 of 24, provide a typical cross section detail for the Rossum Lane extension. 21. On sheet 23 of 24, provide the traffic calmer detail as mentioned on sheet 9 of 24. 22. On sheet 23 of 24, provide details of all traffic signs. 23. On sheet 24 of 24, Senseny is misspelled. Please address the above comments and resubmit. I have enclosed a marked copy of the plans to assist with the revisions. If you have any questions, please feel free to call, 540- 665-5651. Si erely, Lauren E. Krempa Planning Technician M, AIT4 Attachment cc: Quinnelly Group, LLC, 22A Ricketts Drive, Winchester, VA 22601 SUBDIVISION DESIGN PLAN CHECKLIST The subdivision design plan shall be drawn at a scale that is acceptable to the Subdivision Administrator. The subdivision design plan shall include a sheet depicting the full subdivision submitted. The subdivision design plan shall include the following information: VZ title "Subdivision Design Plan for UZ with a notation of all previous names o original property identification number. page number and total pages on each page. name of the owner and/or subdivider subdivision. vicinity map [scale of one to two thousand (1:2000)] showing all roads, properties and subdivisions within one thousand (1000) feet of the subdivision. written and graphic scale. day, month and year plan prepared and revised. 7P North arrow. name of the Magisterial District where located. B C�4 zoning of all land to be subdivided. 9,p boundary survey of all lots, parcels and rights -of -way showing bearings to the nearest minute and distances to the nearest one-hundreth (1/100) of a foot. topography shown at a contour interval acceptable to the Subdivision Administrator but in no case greater than five (5) feet. names of owners, zoning and use iof. all adjoining properties and deed book and �page number references for each adjoining parcel.,��.� pr osed use each with the er lots in ,use c'11y. area of each lot and parcel, the total area of the subdivision and the total area in lots. 10 i location and area of each parcel of common open spaand - the total area of common open space. _--�� '�� c-)�' location, names, right-of-way widths and classifications of existing and planned roads, streets and shared private driveways adjacent to and on the property. existing or proposed utilities, sewer and water lines, manholes, fire hydrants and easements. existing and proposed drainage ways, drainage facilities, culverts and drainage easements with dimensions and design details. stormwater management plan with calculations describing g P g how stormwater management requirements are .being met, including the location and design details of proposed facilities. -r proposed grading plan including spot elevations and flow arrows. cross sections, profiles and design details of all proposed streets, roads, culverts, storm sewers, sanitary sewers and water mains. eXr, Z) -IDA 9(kryl t; - ""� locations, dimensions and cross sections ,of existi g and 0'1 proposed sidewalks and walkways. ') P oo location of environmental features including floodplain, steep slopes, wetlands, sinkholes, woodlands and natural stormwater detention areas. names of all streams and bodies of. water, including all one -hundred -year flood limits as mapped by FEMA. location of all land to be dedicated or reserved for public use. location of required setback lines on each lot. `-� location of proposed recreational areas and facilities. 'ram location of proposed buffers and screening with design, details, locations and types of plants and screening. * proposed landscaping with location and types of plants. certification by an engineer, surveyor or other qualified professional of the accuracy of the plat. ial signature of the owner or principals certifying ownership of the property. statement listing all requirements and conditions placed on the land included in the subdivision resulting from approval of conditional zoning or a conditional use permit. signature line for the Subdivision Administrator. A 12 (�D TL&s(Aj� � howl, �i�v�f a✓� ea,�Qw,p,� ME APPLICATION AND CHECKLIST SUBDIVISION FREDERICK COUNTY VIRGINIA Date: '7 Application # 15--prf MDP? Yes No If no, has MDP requirement' been waived by the Planning Director? Yes No If MDP requirement has not been waived, fill in the following public hearing dates: Planning Commission: Board of Supervisors: Applicant/Agent: Greenway Engineering, Inc Address: 151 Windy Hill Lane Winchester, VA 22602 Phone: 540-662-4185 Owners Name: Quinnelly Group, LLC Address: 22A Ricketts Drive Winchester, VA 22601 Phone: 540-662-4164 Please list names of all owners, principals and/or majority stockholders: Quinnelly Group Contact Person: Jeremy Tweedie, GreenwayEn ing eering Phone: 540-662-4185 NAME OF SUBDIVISION: Senseny Village - Phase 1 Number of Lots: 43 Total Acreage Phase 1-17.19 acres Property Location: South of Rossum Lane (Route 736) and Twinbrook Circle (Route 867)of the Senseny Road Corridor (Give State Rt. #, name, distance and direction from intersection) Magisterial District Red Bud Property Identification Number (PIN) 65-A-49B and 65-A-55 (Parent Tract) Property zoning and present use: RP -Residential Performance Adjoining property zoning and use: RP- Residential Performance Has a Master Development Plan been submitted for this project? X Yes No If yes, has the final MDP been approved by the Board of Supervisors? X Yes No What was the Master Development Plan title? Senseny Village Master Development Plan Does the plat contain any changes from the approved MDP? Yes X No If yes, specify what changes: Minimum Lot Size (smallest lot) 10,000 SF Number and types of housing units in this development: Phase 1-Single Fanily Detached I have read the material included in this package and understand. what is required by the Frederick County Planning Department. I also understand that all required material will be complete rior to the submission of my site plan. Signature Date: ADJACENT PROPERTY OWNERS INFORMATION P.I.N Owner Deed Book and Page or Instrument number Zone Use A 65B-7-10 Randy L. Ruble 020016145 RP Residence B 65D-1-1 Connie B. Linaweaver 606/444 RP Residence C 65D-2-4 Swagler H. II & Brenda S. Koonce 866/220 RP Residence D 65D-2-5 Bettie G. Brumback c/oBetty Kisner 770/1278 RP Residence E 65D-2-6 Bettie G. Brumback c/oBettie G. Brumback Kisner 770/1278 RP Residence F 65D-2-7 Elwynne Godlove 1020009910 IRP Residence G 65D-2-8 Maureen E. Smith 040011444 RP Residence H 65D-2-9 Priscilla McDonald 2004-4790 RP Residence I 65D-2-10A Glenmont Village Association 614/802 RP Green Space J 65D-1-3-37A Glenmont Village Association 583/137 RP Green Space K 65D-3-4-53'Michael Joseph ore RG McDonald Properties, LC 2005-25568 RP Residence L 65D-3-4-54 000005484 IRP Residence M 65D-3-4-59A lGlenmont Village Association 614/802 12007-1883 RP Green Space N 65D-4-5-71 lChristine Mangan RP Residence 0 65D-5-6-76 Kicharcl Vaughn McKee & Dawn McKee Ramona Wilson Drucker & Health Drucker 2005-25674 RP Residence P 65D-5-6-77 050018497 RP Residence 0 65D-5-6-78 Yolanda Funes & Alex Funes 050012670 RP Residence R 65D-5-6-79 Agustin, Maria R. , & Yony A. Cruz 2004-3646 RP Residence S 65D-5-6-80 Hector 1. Perez Valenzuela & Luz Manna Vega Mary Janeczek 2005-25443 RP Residence T 65D-5-6-81 853/1382 RP Residence U 65D-5-6-82 Maritza Santos -Baca & Virgilio Martinez 2006-21871 RP Residence V 65D-5-6-83 Donald E. Nesselrodt 722/716 RP Residence W 65D-5-6-84 Recordo T. & Crystal D. Ford 2006-17049 RP I Residence X 65D-5-6-85 Kim V. & Carolyn S. Ross 724/18 RP Residence Y 65D-5-6-86 James J & Rebecca L Fitzgibbon 723/338 RP Residence Z 65D-5-6-87 Roy W. & Annette M. Lowery 050021488 RP Residence AA 65D-5-6-88 Daniel & Monica O'Hara 030011096 RP BB 65D-5-6-89 Gary Linden Adams & Juanita Spielman Adams 725/724 RP CC 65-A-50 Maurice M. Atkins 582/756 RP DID 65-A-54 Randy Lee & Mary F Ruble 03000577 RP UResidence EE 65-A-56 Genevieve M. Cline RP FF 65-A-57 Winifred D. & Jerry Updyke 040005558 RP GG 65-A-60 Daniel & Jenifer Lafond 040012117 RP Residence HH 65-A-62 Donald L. Roles 2006-11734 RP Residence II 65-A-63 Robert D. Smith & Helen L. Fletcher 030014240 RP Residence JJ 65-A-70 Paul R. Puffinburger 404/335 RP Residence KK 65-A-66 Vicky Lynn & Richard A. Feathers 957/979 RP Residence LL 65-A-65 Maryin L. Swaner 2004-6698 RP Residence MM 65-A-71 Hesham F. Attia & N.S. Khalifa 030016515 RP Residence NN 65-A-68A ILewis F. Franklin, JR. 682/791 RP Residence 00 65B-6-38 Maurice M. Atkins 582/756 RP Residence 65-A-72 EFG Investments, LLC 955/724 RA Unimproved 65-A-186B Ronald F. & Melanie J. Werdebaugh 000006836 RA Residence 65-A-186J Gloria C. Corbin 818/1831 RA Residence 65-A-190 Wilmer R. & Donna N. Davis 2006-24340 RA Unimproved 2 3 4 5 6 COUNTY of FREDERIC_ i - — -. January 16, 2007 Mr. Jeremy Tweedie Greenway Engineering 151 Windy Hill Lane Winchester VA 22602 RE: Review Site Plan Comments — Senseny Village Phase 1 Frederick County, Virginia Dear Mr. Tweedie Upon review of the subject site plan, we offer the following comments: ]department of PoO,ic -740! 665-5+=-s,s FAX: _� 0678A ,„� JA N 1 7 2007 On sheet 3, please include the installation of the sediment basin in the Phase I structural measures list The proposed sediment traps and basin on the site will have a maximum life expectancy of 18 months per VESCH Standa! d 3.13 and 3.14. Due to proffers, completion of the project can not be expected before 2010. Please provide a narrative explaining how this will be addressed. Please provide an analysis for DA-2A as you did for DA-2C on page 10 of the Drainage Calculations. For the existing drainage swales that have an increase in peak flow and cross the adjoining; property before entering the unnamed tributary, a drainage easement will be required. The shallow concentrated flow length for DA-1 is 4320-feet. Per the VESCH page V-4, the maximum recommended len:ih is 1000-feet. Please revise the calculations or provide a detailed justification for your deviation from the recommended length. Please provide a culvert inlet sediment trap at the inlets to the proposed slope drains. A detail for this measure can be founi on page III-50 of the VESCH. We will reserve our approval until receipt of the above revisions. Please submit one copy of the revised plans for further review and highlight on the revised plans the changes listed above. Sincerely, Joe C. Wilder Deputy Director JC W/mlr cc: Mark Cheran, Zoning and Subdivision Administrator file 107 North Kent Street • Winchester, Virginia 22601-5000 REQUEST FOR SUBDIVISION COMMENTS Department of Planning and Development Mail to: Department of Planning and Development Attn: County Planner 107 North Kent Street Winchester, VA 22601 (540) 665-5651 4 Hand deliver to: 107 N. Kent Street Fourth Floor Winchester, VA (540) 665-5651 Please fill out the information as accurately as possible in order to assist the agency with their review. Please attach application, fee, location map, and two (2) copies of the site plain with this sheet. Applicant's name, address and phone number: Greenway Engineering 151 Windy Hill Lane, Winchester, VA 22602 540-662-4185 Name of development and/or description of the request: Senseny Village Phase I - 43 Lots Location of property: South of Rossum Lane (Route 736) and Twinbrook Circle (Route 867) of the Senseny Road Corridor Planning and Development's Comments: 0 GREENWAY ENGINEERING 151 Windy Hill Lane Founded to 1971 Winchester, Virginia 22602 TRANSMITTAL Project Name: Senseny Village, Phase 1-Subdivision Plan File No: 3924 Date: Tue, Jun 19, 2007 To: FC Planning Attn: Candice Perkins Copied Delivery: r Fed Ex I-J U.S. Mail Other From: Jeremy Tweedie/dlm GREENWAY ENGINEERING Phone: 540-662-4185 Fax: 540-722-9528 FJ Courier r] Pick Up Urgent rv] For Your Review Fj As You Requested R] Please Comment Message Candice, Attached is the following for your review and comments: -Subdivision Plan Application -2 copies of the subdivision plan -! copy of adjacent property owners -Application fee check for $6,800.00 -Planning comment sheet Thank you for your assistance. Call with any questions. Hand Delivery and Pick Ups Only: Received by: Date: Please Print Name: PLEASE REVIEW THE ATTACHED DOCUMENT. IF THIS DOCUMENT MEETS YOUR APPROVAL PLEASE INITIAL AND PROVIDE THE DATE AND TIME OF YOUR APPROVAL. IF THIS DOCETAIEANT DOES NO TJ1f EET YOUR APPROVAL PLEASE PROVIDE CO3B ENTSAS TO WHAT YOU WOULD LSE TO HAVE COMPLETED. INITIALS DATE & TE%IE Candice 4 3 - x 1 0 0 • = Bernie 41300• 4s300•00-r 2 1 5 0 0• 0 0+ Susan 61800.00* Eric Mike Kevin John Lauren COMMENTS - Received by Clerical Staff (Date & Time): U:\Pam\Common\Document Approval Form.wpd SUBDIVISION #15-07 SENSENY VILLAGE PH. I Red Bud 43 LOTS 17.19 ACRES IoTG,p A I m