Loading...
55-23 Site PlanCOVER SHEET01 C-GI-001.DWG C-GI-001 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GI-001.DWG, 2/2/2024 3:41 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-GI-001.DWG, 2/2/2024 3:41 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 PROJECT AREA SITE ENTRANCE 310 TYSON DRIVE LOADING DOCK EXPANSION 310 TYSON DRIVE WINCHESTER, VA GAINESBORO MAGISTERIAL DISTRICT FREDERICK COUNTY PIN # 43-19-31 SP #55-23 REVISION TO SP #63-22 VICINITY MAP (SCALE 1" = 300') PROJECT DIRECTORY: PANNING & DEVELOPMENT 107 NORTH KENT STREET SUITE 202 WINCHESTER, VA 22601 540-665-5651 WATER AND SEWER WINCHESTER PUBLIC UTILITIES 15 NORTH CAMERON STREET WINCHESTER, VA 22601 540-667-1815 FREDERICK WATER 315 TASKER ROAD STEPHENS CITY, VA 22655 540-868-1429 ENGINEER: GORDON US LLC ADDRESS: 4501 DALY DRIVE, SUITE 200 CHANTILLY, VIRGINIA 20151 PHONE: 703-263-7989 CONTACT: CHRIS KINGSLAND, SENIOR PROJECT MANAGER EMAIL: CKINGSLAND@GORDON.US.COM DEVELOPER: LINCOLN PROPERTY COMPANY ADDRESS: 1530 WILSON BOULEVARD SUITE 200 ARLINGTON, VA 22209 PHONE: 703-284-3344 CONTACT: CHRIS COX, CONSTRUCTION MANAGER EMAIL: CCOX@LPC.COM OWNER: RBG TYSON ASSOCIATES LLC C/O RBG HOLDINGS LLC ADDRESS: 1100 WILSON BOULEVARD SUITE 210 ARLINGTON, VA 22209 PHONE: 202-839-3600 M C G H E E R O A D TYSON DRIVEMCGHEE ROADPROJECT DESCRIPTION: THE EXISTING USE OF THE PROPERTY IS WAREHOUSING AND OFFICE SPACE WITH MULTIPLE LOADING DOCKS ALONG THE SOUTH WESTERN PORTION OF THE BUILDING. THIS PROJECT IS PROPOSING A LOADING DOCK ADDITION, INCLUDING A DRIVE IN RAMP, THE RELOCATION OF STORM DRAINS AND FIRE HYDRANTS AT THE BACK OF THE BUILDING, AND THE MAINTENANCE OF AN EXISTING DRY POND. NO CHANGE TO THE EXISTING USE IS PROPOSED. THIS SITE PLAN IS A REVISION TO CHANGE THE GRADING FOR THE LOADING DOCK EXPANSION APPROVED THROUGH SP #63-22. PREVIOUSLY APPROVED PLANS: VALLEY HEALTH EPIC TRAINING CENTER (SP #26-13) SP #33-87, SP #02-96, SP #20-98, SP #20-15 SITE TABULATIONS: ZONING: M-1 LIGHT INDUSTRIAL ADJACENT ZONING: ALL USES WITHIN 500 FEET ARE ZONED M-1 LIGHT INDUSTRIAL LAND USE: WAREHOUSING AND OFFICE (SIC - 49) SITE AREA: EXISTING TOTAL AREA OF SITE = 653,400 SF OR 15.00 AC PROPOSED DEVELOPMENT AREA = 48,385 SF OR 1.11 AC DIMENSIONAL REQUIREMENTS: FRONT YARD SETBACK = 75 FT SIDE YARD SETBACK = 25 FT REAR YARD SETBACK = 25 FT HEIGHT LIMIT: MAXIMUM HEIGHT = 60 FT BUILDING HEIGHT = 28.5 FT AREA REQUIREMENTS: TOTAL GROUND FLOOR AREA = 226,730 SF TOTAL LOT AREA = 653,400 SF PROPOSED GROUND FLOOR AREA = 230,980 SF MAX FLOOR AREA TO LOT AREA RATIO (FAR) = 1.0 PROPOSED FAR = 0.35 MINIMUM LANDSCAPED AREA = 25% PROPOSED LANDSCAPED AREA = 37.15% IMPERVIOUS AREAS: EXISTING IMPERVIOUS AREA = 35,593 SF OR 0.82 AC PROPOSED IMPERVIOUS AREA = 39,511 SF OR 0.91 AC PROPOSED IMPERVIOUS AREA REQUIRING TREATMENT = 3,918 SF OR 0.09 AC PARKING TABULATION: ZONING ANALYSIS -FOR 201 TO 300 TOTAL SPACES, 7 ADA PARKING SPACES ARE REQUIRED WITH A MINIMUM OF 2 VAN SPACES -PER FREDERICK COUNTY ZONING REQUIREMENTS 1.5 SPACES PER WAREHOUSE EMPLOYEE 1 SPACE PER 250 SQUARE FEET OF OFFICE FLOOR AREA 1 SPACE FOR EACH COMPANY VEHICLE AND EQUIPMENT STORED OUTSIDE TABULATION -WAREHOUSE EMPLOYEE TOTAL = 80 + 21 = 101 EMPLOYEES 152 PARKING SPACES -OFFICE SPACE TOTAL = 6,888 SF + 6,168 SF = 13,056 SF 53 PARKING SPACES COMPLIANCE (SEE TABLE) -205 TOTAL PARKING SPACES REQUIRED 198 STANDARD PARKING SPACES PROVIDED -7 ADA SPACES REQUIRED (2 VAN) 3 ADA SPACES PROVIDED IN THE REAR AND 4 IN THE FRONT FOR A TOTAL OF 7 APPROVED BY THE FREDERICK COUNTY ZONING ADMINISTRATOR SIGNATURE DATE SITE PLAN VALID FOR FIVE (5) YEARS FROM APPROVAL DATELOCATION MAP (SCALE 1" = 1000') PROJECT SITE RESPONSIBLE LAND DISTURBER NAME:______________________________________________________ CERTIFICATION #: ____________________________________________ DATE:______________________________________________________ THE RESPONSIBLE LAND DISTURBER IS THAT PARTY RESPONSIBLE FOR CARRYING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. SHEET INDEX Sheet Number Sheet Title 01 COVER SHEET 02 GENERAL NOTES, ABBREVIATIONS, AND LEGEND 03 EXISTING CONDITIONS 04 DEMOLITION PLAN 05 DRY POND DEMOLITION PLAN 06 SITE PLAN 07 DIMENSIONING AND JOINT LAYOUT PLAN 08 GRADING AND DRAINAGE PLAN 09 DRY POND GRADING AND DRAINAGE PLAN 10 UTILITY PLAN 11 WATER MAIN PROFILE AND UTILITY DETAILS 12 STORM SEWER PROFILE AND COMPUTATIONS 13 UTILITY DETAILS 14 UTILITY DETAILS 15 SITE DETAILS 16 SITE DETAILS 17 SITE DETAILS 18 SITE DETAILS 19 EROSION AND SEDIMENT CONTROL NOTES 20 EROSION AND SEDIMENT CONTROL PLAN PHASE 1 21 DRY POND EROSION AND SEDIMENT CONTROL PLAN PHASE 1 22 EROSION AND SEDIMENT CONTROL PLAN PHASE 2 23 DRY POND EROSION AND SEDIMENT CONTROL PLAN PHASE 2 24 EROSION AND SEDIMENT CONTROL DETAILS 25 PRE & POST-DEVELOPMENT LAND COVER MAPS 26 PRE & POST-DEVELOPMENT DRIANAGE AREA MAPS 27 WATER QUALITY COMPUTATIONS 28 STORMWATER SPECIFICATIONS 29 LANDSCAPE PLAN OVERALL 30 LANDSCAPE PLAN 31 LANDSCAPE PLAN 32 LANDSCAPE CALCULATIONS AND DETAILS GENERAL NOTES, ABBREVIATIONS, AND LEGEND02 C-GI-002.DWG C-GI-002 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GI-002.DWG, 2/2/2024 3:41 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-GI-002.DWG, 2/2/2024 3:41 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 MH MANHOLE MI MILE MS MEDIAN STRIP MSL MEAN SEA LEVEL MON MONUMENT N/F NOW OR FORMERLY NCA NATIONAL CEMETERY ADMINISTRATION NIC NOT IN CONTRACT NFA NET FLOOR AREA NO, #NUMBER NBL NORTH BOUND LANE OC ON CENTER OC OVERHEAD COMMUNICATIONS OD OUTSIDE DIAMETER OE OVERHEAD ELECTRIC OH OVERHANG P PERIMETER PC POINT OF CURVATURE PCC POINT OF COMPOUND CURVE PCEP POINT OF CURVE, EDGE OF PAVEMENT PCTC POINT OF CURVE, TOP OF CURB PD PAVEMENT DRAIN PERF PERFORATED PG PAGE PGL POINT OF GRADE LINE PH PROFILE HOLE PI POINT OF INTERSECTION PL PROPERTY LINE POV PRIVATELY OWNED VEHICLE PRC POINT OF REVERSE CURVE PRELIMPRELIMINARY PROP PROPOSED PT POINT OF TANGENCY PVC POINT OF VERTICAL CURVATURE PVC POLY VINYL CHLORIDE (PLASTIC PIPE) PVI POINT OF VERTICAL INTERSECTION PVMT PAVEMENT PVT POINT OF VERTICAL TANGENCY P&P PLAN AND PROFILE Q FLOW, AMOUNT OF RUNOFF R RISER, RADIUS R&CAPREBAR W/ A CAP RCP REINFORCED CONCRETE PIPE RD ROAD, ROOF DRAIN RDM RAPID DRAINAGE MATERIAL RW RETAINING WALL REV REVISION RGP ROUGH GRADING PLAN RR RAILROAD RTE ROUTE RT RIGHT R/W RIGHT OF WAY SAN SANITARY SBL SOUTH BOUND LANE SEC SECTION SEW SEWER SP SITE PLAN SPEC SPECIFICATION STA STATION STE STEAM STD STANDARD STK STACK STM STORM SVC SERVICE S/W SIDEWALK Sx CROSS SLOPE T TANGENT TB TEST BORE TC TOP OF CURB TCP TERRA COTTA PIPE TELE TELEPHONE TH TEST HOLE TP TEST PIT TB TOP OF BANK TW TOP OF WALL UC UNDERGROUND COMMUNICATIONS UD UNDERDRAIN UGE UNDERGROUND ELECTRIC U/G UNDERGROUND UL UPPER LEVEL UP UTILITY POLE V VELOCITY VCP VITRIFIED CLAY PIPE VF VERTICAL FOOT W WATER W/M WATERMAIN W.M.WATER METER WSE WATER SURFACE ELEVATION WBL WEST BOUND LANE X-ING CROSSING YI YARD INLET YR YEAR Z SIDE SLOPES A AREA OR ARC AC ACRE AE ABOVE GROUND ELECTRIC AGEC ABOVE GROUND ELECTRIC CONDUIT ANSI AMERICAN NATIONAL STANDARDS INSTITUTE APPROX APPROXIMATE ARCH ARCHITECTURAL ASPH ASPHALT BC BOTTOM OF CURB BF BASEMENT FLOOR BL BASE LINE BLDG BUILDING BM BENCHMARK BOV BLOW OFF VALVE BRL BUILDING RESTRICTION LINE BW BOTTOM OF WALL C COEFFICIENT OF RUNOFF CB CATCH BASIN OR CHORD BEARING CC CENTER TO CENTER CFS CUBIC FEET PER SECOND CHD CHORD CG CURB AND GUTTER CIP CAST IRON PIPE CL CENTERLINE CMP CORRUGATED METAL PIPE CONC CONCRETE CO CLEAN OUT COMM COMMUNICATIONS CONN CONNECTION CON CONTAMINATED CONT CONTINUATION COR CONTRACTING OFFICERS REPRESENTATIVE CT COURT D DEPTH DB DEED BOOK DET DETAIL DGA DENSE GRADED AGGREGATE DI DROP INLET DIP DUCTILE IRON PIPE DM DROP MANHOLE DOM DOMESTIC DR DRIVE DWG DRAWING D/W DRIVEWAY D DELTA EC EDGE OF CONCRETE ESMT EASEMENT EG EDGE OF GUTTER ELEV ELEVATION EP EDGE OF PAVEMENT ES END SECTION EW END WALL EXP EXPANSION EX EXISTING ELEC ELECTRICAL EBL EAST BOUND LANE FAR FLOOR AREA RATIO FC FACE OF CURB FD FOUNDATION DRAIN FF FIRST FLOOR OR FINISHED FLOOR FG FINISHED GRADE FH FIRE HYDRANT FP FLOOD PLAIN FR FROM G GAS GFA GROSS FLOOR AREA GR GRADE GR GUARD RAIL HC HANDICAP HERCP HORIZONTAL ELLIPTICAL REINFORCED CONCRETE PIPE HGL HYDRAULIC GRADE LINE HP HIGH POINT HR HAND RAIL HT HEIGHT HWSR HOT WATER SUPPLY & RETURN I RAINFALL INTENSITY ID INSIDE DIAMETER IN INCH INV INVERT IP IRON PIPE IPF IRON PIPE FOUND IPS IRON PIPE SET JB JUNCTION BOX K ONE THOUSAND (KILO) L LENGTH LAT LATERAL LL LOWER LEVEL LOC LOCATION LP LOW POINT LT LEFT MAT MATERIAL MECH MECHANICAL MEP MECHANICAL, ELECTRICAL, PLUMBING OHE TEL BX C RD LEGEND W LCG LCG Wx 724 724 +24 00X 24.00 GENERAL NOTES 1.THIS PROJECT PROPOSED ADDING A 4-FOOT TALL LOADING DOCK FOR MULTIPLE TRUCK BAYS AND DRIVE-IN RAMPS ON THE WEST SIDE OF THE EXISTING BUILDING. THIS WILL REQUIRE A RECONFIGURATION OF THE EXISTING PARKING AT THE BACK OF THE BUILDING, RELOCATED ADA PARKING, STORMWATER STRUCTURES, AND FIRE HYDRANT LOCATIONS. 2.THE PROPERTY IS LOCATED IN FREDERICK COUNTY, VA, IDENTIFIED AS SHOWN ON THE FREDERICK COUNTY TAX MAP AS PIN NUMBER 43-19-31. 3.THE PROPERTY IS ZONED M-1 LIGHT INDUSTRIAL, THE EXISTING USE IS A WAREHOUSING AND OFFICE. 4.THE PROPERTY CONSISTS OF 653,400 SQUARE FEET OR 15.00 ACRES. 5.DISTURBED AREA FOR THE PROJECT IS APPROXIMATELY 1.11 ACRES OR 48,385 SF. 6.TO THE BEST OF OUR KNOWLEDGE AND BELIEF, THERE IS NO EVIDENCE OF ANY GRAVE, OBJECT OR STRUCTURE MARKING A PLACE OF BURIAL ON THIS PROPERTY. 7.TO THE BEST OF OUR KNOWLEDGE AND BELIEF, THERE IS NO EVIDENCE OF ANY HISTORIC SITES ON THIS PROPERTY. 8.GORDON DOES NOT CERTIFY TO THE LOCATION OF OR THE EXISTENCE OF ANY EXISTING UNDERGROUND UTILITIES. THE EXISTING UNDERGROUND UTILITIES SHOWN HEREON ARE BASED UPON AVAILABLE INFORMATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATION OF ALL UTILITIES BEFORE COMMENCING WORK AND FOR ANY DAMAGES WHICH OCCUR BY HIS FAILURE TO LOCATE OR PRESERVE THESE UNDERGROUND UTILITIES. IF DURING CONSTRUCTION OPERATIONS THE CONTRACTOR SHOULD ENCOUNTER UTILITIES OTHER THAN THOSE SHOWN ON THE PLAN, HE SHALL IMMEDIATELY NOTIFY THE ENGINEER AND TAKE NECESSARY AND PROPER STEPS TO PROTECT THE FACILITY AND INSURE THE CONTINUANCE OF SERVICE. IF NECESSARY, THE SITE PLAN WILL BE MODIFIED TO ELIMINATE THE CONFLICT AT THE DEVELOPER'S EXPENSE. 9.ALL PROPOSED GRADES AS SHOWN HEREIN ARE FINISHED GRADE UNLESS NOTED ON THE PLAN. 10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE OWNER AND THE ENGINEER OF ANY CHANGES OR CONDITIONS ATTACHED TO PERMITS OBTAINED FROM THE ANY AUTHORITY ISSUING PERMITS. 11.ALL LAND, ON OR OFF SITE, WHICH IS DISTURBED BY THIS DEVELOPMENT, AND WHICH IS NOT BUILT UPON OR SURFACED, SHALL BE ADEQUATELY STABILIZED TO CONTROL EROSION AND SEDIMENTATION. 12.THE CONTRACTOR SHALL PROVIDE ADEQUATE MEANS OF CLEANING TRUCKS AND/OR OTHER EQUIPMENT OF MUD PRIOR TO ENTERING THE RIGHT-OF-WAY, AND IT IS THE CONTRACTORS RESPONSIBILITY TO CLEAN STREETS OF MUD AND/OR ALLAY DUST AND TO TAKE WHATEVER MEASURES NECESSARY TO ENSURE THAT THE STREETS ARE KEPT IN A CLEAN AND DUST FREE CONDITION AT ALL TIMES. 13.DURING CONSTRUCTION, THE CONTRACTOR SHALL PROVIDE BUILDING MANAGER WITH 72 HOURS NOTICE IF SERVICE WILL BE AFFECTED DURING UTILITY INSTALLATION. 14.THE CLIENT, CONTRACTOR, AND/OR SURVEYOR SHALL BE RESPONSIBLE FOR NOTIFYING GORDON OF ANY CONDITIONS FOUND IN THE FIELD THAT VARY FROM WHAT IS SHOWN ON THE PLANS. OBSERVATIONS REGARDING APPARENT INCONSISTENCIES IN THE PLANS SHALL BE BROUGHT TO GORDON'S ATTENTION FOR VERIFICATION PRIOR TO STAKEOUT. 15.ALL HANDICAPPED PARKING SPACES SHALL CONFORM TO THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT. (ADA - CURRENT VERSION). ALL TRAILS/SIDEWALKS SHALL COMPLY WITH ADA REQUIREMENTS 16.CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH PERFORMANCE OF ITS WORK AND THE WORK OF ITS SUBCONTRACTORS. GORDON SHALL NOT HAVE CONTROL OVER, CHARGE OF, OR RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. 17.MAINTAIN A MINIMUM VERTICAL CLEARANCE OF ONE (1) FOOT SIX (6) INCHES BETWEEN CROSSINGS OF ALL UTILITY LINES UNLESS OTHERWISE NOTED. 18.APPROVAL OF THIS PLAN SHALL IN NO WAY GRANT PERMISSION BY THE APPROVING JURISDICTION FOR THE CONTRACTOR TO TRESPASS ON OFF-SITE PROPERTIES. 19.WHERE THE ORDINANCES DIFFER BETWEEN LOCAL, STATE, AND FEDERAL REQUIREMENTS, THE MOST RESTRICTIVE SHALL APPLY. 20.ALL EARTHMOVING, EARTHEN MATERIALS, EXCAVATION, FILL, BACKFILL, COMPACTION, EMBANKMENT MODIFICATIONS OR CONSTRUCTION, AND CULVERT MODIFICATIONS SHALL BE IN ACCORDANCE WITH THE RECOMMENDATIONS AND INSTRUCTIONS INCLUDED IN THE GEOTECHNICAL REPORT BY ECS DATED OCTOBER 16TH, 2023. PROVIDE ALL TESTS AND VERIFICATIONS AS INDICATED BY THE GEOTECHNICAL ENGINEERING REPORT. 21.THE CONTRACTOR SHALL IDENTIFY ALL STAGING AREAS AND LIMITS OF WORK/DISTURBANCE. AREAS OUTSIDE LIMITS OF WORK/DISTURBANCE SHALL NOT BE USED FOR STORAGE OR MOVEMENT OF MATERIALS, MACHINERY OR DEBRIS. 22.THE CONTRACTOR SHALL NOTIFY "MISS UTILITY OF VIRGINIA" DIAL 811 OR 1-800-552-7001, 48 HOURS PRIOR TO THE START OF ANY EXCAVATION OR CONSTRUCTION, FOR THE MARKING OF UNDERGROUND UTILITIES. 23.ALL PRODUCTS AND INSTALLATION SHALL BE IN ACCORDANCE WITH VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT), VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (VESCH), AND FREDERICK COUNTY ORDINANCES. IF A CONFLICT EXISTS, THE MOST STRINGENT REQUIREMENTS SHALL APPLY. VDOT GENERAL NOTES: V1. ALL WORK ON THIS PROJECT SHALL CONFORM TO THE CURRENT EDITIONS OF AND LATEST REVISIONS TO THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT) ROAD AND BRIDGE SPECIFICATIONS AND STANDARDS, THE VIRGINIA EROSION AND SEDIMENT CONTROL REGULATIONS, AND ANY OTHER APPLICABLE STATE, FEDERAL OR LOCAL REGULATIONS. IN CASE OF A DISCREPANCY OR CONFLICT BETWEEN THE STANDARDS OR SPECIFICATIONS AND REGULATIONS, THE MOST STRINGENT SHALL GOVERN. V2. ALL CONSTRUCTION SHALL COMPLY WITH THE LATEST U.S. DEPARTMENT OF LABOR, OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), AND VIRGINIA OCCUPATIONAL SAFETY & HEALTH (VOSH) RULES AND REGULATIONS. V3. WHEN WORKING WITHIN VDOT RIGHT-OF-WAY, ALL TRAFFIC CONTROL, WHETHER PERMANENT OR TEMPORARY, SHALL BE IN ACCORDANCE WITH THE CURRENT EDITION OF VDOT’S WORK AREA PROTECTION MANUAL. A TRANSPORTATION MANAGEMENT PLAN NEEDS TO BE SUBMITTED FOR APPROVAL AND LAND USE PERMIT ISSUED PRIOR TO ANY EXECUTION OF WORK WITHIN THE VDOT RIGHT OF WAY. V4. THE DEVELOPER SHALL BE RESPONSIBLE FOR RELOCATING, AT HIS EXPENSE, ANY AND ALL UTILITIES, INCLUDING TRAFFIC SIGNAL POLES, JUNCTION BOXES, CONTROLLERS, ETC., OWNED BY VDOT OR PRIVATE / PUBLIC UTILITY COMPANIES. IT IS THE SOLE RESPONSIBILITY OF THE DEVELOPER TO LOCATE AND IDENTIFY UTILITY FACILITIES OR ITEMS THAT MAY BE IN CONFLICT WITH THE PROPOSED CONSTRUCTION ACTIVITY. VDOT APPROVAL OF THESE PLANS DOES NOT INDEMNIFY THE DEVELOPER FROM THIS RESPONSIBILITY. V5. DESIGN FEATURES RELATING TO FIELD CONSTRUCTION, REGULATIONS, AND CONTROL OR SAFETY OF TRAFFIC MAY BE SUBJECT TO CHANGE AS DEEMED NECESSARY BY VDOT. ANY ADDITIONAL EXPENSE INCURRED AS A RESULT OF ANY FIELD REVISION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. V6. IF REQUIRED BY THE LOCAL VDOT LAND DEVELOPMENT OFFICE, A PRE-CONSTRUCTION CONFERENCE SHALL BE ARRANGED AND HELD BY THE ENGINEER AND/OR DEVELOPER WITH THE ATTENDANCE OF THE CONTRACTOR (S), VARIOUS COUNTY AGENCIES, UTILITY COMPANIES AND VDOT PRIOR TO INITIATION OF WORK. V7. THE CONTRACTOR SHALL NOTIFY THE LOCAL VDOT LAND DEVELOPMENT OFFICE WHEN WORK IS TO BEGIN OR CEASE FOR ANY UNDETERMINED LENGTH OF TIME. VDOT REQUIRES AND SHALL RECEIVE 48 HOURS ADVANCE NOTICE PRIOR TO ANY REQUIRED OR REQUESTED INSPECTION. V8. THE CONTRACTOR SHALL NOTIFY THE TRAFFIC OPERATIONS CENTER AT (540) 332-9500 FOR ANY TRAFFIC CONTROL PLAN THAT IMPACTS A VDOT MAINTAINED INTERSTATE OR PRIMARY ROADWAY TO PROVIDE NOTIFICATION OF THE INSTALLATION AND REMOVAL OF THE WORK ZONE. V9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING A VDOT PERMITTED TEMPORARY CONSTRUCTION ENTRANCE(S) IN ACCORDANCE WITH SECTION 3.02 OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. FURTHERMORE, ACCESS TO OTHER PROPERTIES AFFECTED BY THIS PROJECT SHALL BE MAINTAINED THROUGH CONSTRUCTION. V10. CONTRACTOR SHALL ENSURE ADEQUATE DRAINAGE IS ACHIEVED AND MAINTAINED ON THE SITE DURING AND AT THE END OF CONSTRUCTION. V11. ALL WATER AND SEWER LINES WITHIN EXISTING OR PROPOSED VDOT RIGHT-OF-WAY SHALL HAVE A MINIMUM THIRTY-SIX (36) INCHES COVER AND WHEN POSSIBLE SHALL BE INSTALLED UNDER ROADWAY DRAINAGE FACILITIES AT CONFLICT POINTS. V12. ANY UNUSUAL SUBSURFACE CONDITIONS (E.G., UNSUITABLE SOILS, SPRINGS, SINKHOLES, VOIDS, CAVES, ETC.) ENCOUNTERED DURING THE COURSE OF CONSTRUCTION SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER AND VDOT. WORK SHALL CEASE IN THAT VICINITY UNTIL AN ADEQUATE DESIGN CAN BE DETERMINED BY THE ENGINEER AND APPROVED BY VDOT. V13. ALL FILL AREAS, BORROW MATERIAL AND UNDERCUT AREAS SHALL BE INSPECTED AND APPROVED BY A VDOT REPRESENTATIVE PRIOR TO PLACEMENT OF FILL. A VDOT REPRESENTATIVE SHALL BE PRESENT TO INSURE THE SOIL SAMPLE(S) OBTAINED FOR CBR’S IS REPRESENTATIVE OF THE LOCATION. WHEN SOIL SAMPLES ARE SUBMITTED TO PRIVATE LABORATORIES FOR TESTING, THE SAMPLES SHALL BE CLEARLY IDENTIFIED AND LABELED AS BELONGING TO A PROJECT TO BE ACCEPTED BY VDOT AND THAT TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE VDOT STANDARDS AND PROCEDURES. V14. ALL ROADWAY FILL, BASE, SUBGRADE MATERIAL, AND BACKFILL IN UTILITY/STORM SEWER TRENCHES SHALL BE COMPACTED IN ACCORDANCE WITH THE LIFT THICKNESSES, DENSITY AND MOISTURE REQUIREMENTS AS SPECIFIED IN THE CURRENT VDOT ROAD AND BRIDGE SPECIFICATIONS. CERTIFIED COPIES OF TEST REPORTS SHALL BE SUBMITTED TO VDOT DAILY, UNLESS SPECIFIED OTHERWISE. V15. VDOT STANDARD CD AND UD UNDERDRAINS SHALL BE INSTALLED WHERE INDICATED ON THESE PLANS AND/OR AS SPECIFIED BY VDOT. V16. A POST INSTALLATION VISUAL/VIDEO CAMERA INSPECTION SHALL BE CONDUCTED BY THE CONTRACTOR ON ALL PIPES IDENTIFIED ON THE PLANS AS STORM SEWER PIPE AND A SELECT NUMBER OF PIPE CULVERTS. FOR PIPE CULVERTS, A MINIMUM OF ONE PIPE INSTALLATION FOR EACH SIZE OF EACH MATERIAL TYPE WILL BE INSPECTED OR TEN PERCENT OF THE TOTAL AMOUNT FOR EACH SIZE AND MATERIAL TYPE SUMMARIZED. ALL PIPE INSTALLATIONS ON THE PLANS NOT IDENTIFIED AS STORM SEWER PIPE SHALL BE CONSIDERED AS CULVERT PIPE FOR INSPECTION PURPOSES. ADDITIONAL TESTING MAY BE REQUIRED AS DIRECTED BY THE AREA LAND USE ENGINEER OR THEIR REPRESENTATIVE. V17. THE INSTALLATION OF ANY ENTRANCES AND MAILBOXES WITHIN ANY DEDICATED STREET RIGHT-OF-WAY SHALL MEET VDOT MINIMUM DESIGN STANDARDS AND IS THE RESPONSIBILITY OF THE DEVELOPER. V18. PRIOR TO VDOT ACCEPTANCE OF ANY STREETS, ALL REQUIRED STREET SIGNAGE AND/OR PAVEMENT MARKINGS SHALL BE INSTALLED BY THE DEVELOPER IN ACCORDANCE WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. V19. THE DEVELOPER SHALL PROVIDE THE VDOT LAND DEVELOPMENT OFFICE WITH A LIST OF ALL MATERIAL SOURCES PRIOR TO THE START OF CONSTRUCTION. COPIES OF ALL INVOICES FOR MATERIALS UTILIZED WITHIN ANY DEDICATED STREET RIGHT-OF-WAY MUST BE PROVIDED TO THE LOCAL VDOT LAND DEVELOPMENT OFFICE PRIOR TO ACCEPTANCE OF THE WORK. UNIT AND TOTAL PRICES MAY BE OBSCURED. V20. AGGREGATE BASE AND SUBBASE MATERIALS SHALL BE PLACED ON SUBGRADE BY MEANS OF A MECHANICAL SPREADER. DENSITY WILL BE DETERMINED USING THE DENSITY CONTROL STRIP IN ACCORDANCE WITH SECTION 304 OF THE VDOT ROAD AND BRIDGE SPECIFICATIONS AND VTM-10. A CERTIFIED COMPACTION TECHNICIAN SHALL PERFORM THESE TESTS. CERTIFIED COPIES OF TEST REPORTS SHALL BE SUBMITTED TO VDOT DAILY, UNLESS SPECIFIED OTHERWISE. IN ADDITION TO CHECKING STONE DEPTHS, A VDOT REPRESENTATIVE SHALL BE NOTIFIED AND GIVEN THE OPPORTUNITY TO BE PRESENT DURING THE CONSTRUCTION AND TESTING OF THE DENSITY CONTROL STRIP. V21. ASPHALT CONCRETE PAVEMENTS SHALL BE PLACED IN ACCORDANCE WITH SECTION 315 OF THE VDOT ROAD AND BRIDGE SPECIFICATIONS. DENSITY SHALL BE DETERMINED USING THE DENSITY CONTROL STRIP AS SPECIFIED IN SECTION 315 AND VTM-76. A CERTIFIED COMPACTION TECHNICIAN SHALL PERFORM THESE TESTS. CERTIFIED COPIES OF TEST REPORTS SHALL BE SUBMITTED TO VDOT DAILY, UNLESS SPECIFIED OTHERWISE. A VDOT REPRESENTATIVE SHALL BE NOTIFIED AND GIVEN THE OPPORTUNITY TO BE PRESENT DURING THE CONSTRUCTION AND TESTING OF THE CONTROL STRIP. V22. IN ACCORDANCE WITH SECTION 302.03, THE FOUNDATIONS FOR PIPE CULVERTS THIRTY-SIX (36) INCHES AND LARGER SHALL BE EXPLORED BELOW THE BOTTOM OF THE EXCAVATION TO DETERMINE THE TYPE AND CONDITION OF THE FOUNDATION. THE CONTRACTOR SHALL REPORT FINDINGS OF FOUNDATION EXPLORATION TO THE ENGINEER AND VDOT FOR APPROVAL PRIOR TO PLACING PIPE. FOUNDATION DESIGNS SHALL COMPLY WITH VDOT ROAD AND BRIDGE STANDARD PB-1. WHERE SOFT, YIELDING, OR OTHERWISE UNSUITABLE FOUNDATION IS ENCOUNTERED, THE FOUNDATION DESIGN AND/OR NEED FOR FOUNDATION STABILIZATION SHALL BE DETERMINED BY THE ENGINEER AND APPROVED BY VDOT. V23. VDOT STANDARD GUARDRAIL SHALL BE INSTALLED WHERE WARRANTED AND/OR AS PROPOSED ON THESE PLANS IN ACCORDANCE WITH VDOT’S INSTALLATION CRITERIA. FINAL APPROVAL OF THE GUARDRAIL LAYOUT TO BE GIVEN BY VDOT AFTER GRADING IS MOSTLY COMPLETE. V24. APPROVAL OF THESE PLANS SHALL EXPIRE FIVE (5) YEARS FROM THE DATE OF THE APPROVAL LETTER. V25. VDOT STANDARD CG-12 CURB RAMPS SHALL BE INSTALLED WHERE INDICATED ON THESE PLANS AND/OR AS SPECIFIED BY VDOT. V26. THE FOUNDATIONS FOR ALL BOX CULVERTS SHALL BE INVESTIGATED BY MEANS OF EXPLORATORY BORINGS ADVANCED BELOW PROPOSED FOUNDATION ELEVATION TO DETERMINE THE TYPE AND CONDITION OF THE FOUNDATION. THE CONTRACTOR SHALL SUBMIT COPIES OF BOREHOLE LOGS AND REPORT FINDINGS OF FOUNDATION EXPLORATION TO THE ENGINEER AND VDOT FOR APPROVAL PRIOR TO CONSTRUCTING BOX. FOUNDATION DESIGNS SHALL COMPLY WITH VDOT ROAD AND BRIDGE STANDARD PB-1. CONTRARY TO THE STANDARD, WHERE ROCK IS ENCOUNTERED AND CAST-IN-PLACE BOX IS PROPOSED, THE THICKNESS OF BEDDING SHALL BE SIX (6) INCHES. WHERE SOFT, YIELDING, OR OTHERWISE UNSUITABLE FOUNDATION IS ENCOUNTERED, THE FOUNDATION DESIGN AND/OR NEED FOR FOUNDATION STABILIZATION SHALL BE DETERMINED BY THE ENGINEER AND APPROVED BY VDOT. ABBREVIATIONS SIGN TREE FIRE HYDRANT STORM DRAINAGE MANHOLE STORM DRAINAGE GRATE INLET STORM DRAINAGE CULVERT POWER POLE ELECTRIC TRANSFORMER LIGHT POLE HANDICAP PARKING MARKING GUY WIRE OVERHEAD WIRE SHRUB MAILBOX CHAIN LINK FENCE BOARD FENCE TREE LINE COMMUNICATION BOX COMMUNICATION HANDHOLE GUARD RAIL ELECTRIC BOX GROUND LIGHT ELECTRIC PANEL ELECTRIC HANDHOLE SANITARY SEWER MANHOLE WATER VALVE ROOF DRAIN DOWNSPOUT HVAC UNIT EXISTING PROPOSED PROPERTY LINE EASEMENT LINE BUILDING FACE RETAINING WALL CURB AND GUTTER WATER MAIN STORM DRAINAGE STRUCTURE STORM DRAINAGE PIPE CONTOURS SPOT ELEVATION CONCRETE HEAVY DUTY ASPHALT PAVEMENT ASPHALT SURFACE COURSE LIMITS OF CLEARING AND GRADING REDUCER DUMPSTER PAD SETBACK LINE BOLLARD TRENCH DRAIN LCG ADA CONSTRUCTION NOTES: 1.ALL ACCESSIBLE ROUTES SHALL COMPLY WITH AMERICANS WITH DISABILITIES ACT (ADA) REQUIREMENTS. 2.ACCESSIBLE ROUTES SHALL BE SLOPED NO MORE THAN 5% LONGITUDINALLY. ACCESSIBLE ROUTES WITH SLOPES BETWEEN 5% AND 8.33% SHALL BE CONSTRUCTED AS RAMPS, AND SHALL INCLUDE HANDRAILS, AND LANDINGS SPACED NO MORE THAN 30 FEET APART. 3.THE CONTRACTOR SHALL CONSTRUCT LANDINGS AT A MINIMUM OF 5 FEET IN LENGTH AND SHALL BE AT LEAST AS WIDE AS THE RAMP. 4.THE CROSS SLOPE OF ALL ACCESSIBLE ROUTES, INCLUDING RAMPS AND LANDINGS, SHALL BE NO GREATER THAN 1:48. OUTDOOR LIGHTING: 1.NO ADDITIONAL OUTDOOR LIGHTS ARE PROPOSED WITH THIS PROJECT. FREDERICK WATER CONSTRUCTION NOTES: 1.FREDERICK WATER’S WATER AND SEWER STANDARDS AND SPECIFICATIONS ARE AVAILABLE AT WWW.FREDERICKWATER.COM 2.THE CONTRACTOR SHALL ADHERE TO FREDERICK WATER STANDARDS AND SPECIFICATIONS IN EFFECT AT THE TIME OF CONSTRUCTION. 3.THE CONTRACTOR SHALL SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE FREDERICK WATER INSPECTOR PRIOR TO COMMENCING INSTALLATION OF ANY WATER OR SEWER FACILITIES. CONTRACTOR SHALL ALSO ARRANGE FOR INSPECTION OF SAID FACILITIES BY FREDERICK WATER. OIL WATER SEPARATORS AND/OR GREASE TRAPS MAY BE REQUIRED BY FREDERICK COUNTY BUILDING INSPECTIONS. BOTH FREDERICK COUNTY BUILDING INSPECTIONS AND FREDERICK WATER WILL INSPECT THE INSTALLATION OF THOSE FACILITIES. BOTH INSPECTIONS SHALL BE SCHEDULED BY CONTRACTOR. 4.EXACT LOCATIONS OF WATER AND SEWER SERVICES ON NEW LINES ARE TO BE COORDINATED WITH FREDERICK WATER’S INSPECTOR. a.ADJUST FREDERICK WATER FACILITIES TO GRADE AS REQUIRED BY THE FREDERICK WATER INSPECTOR. 719718718717718 719 720 721 722 723 7 2 4 725 725720720722723724720722723724723724 725 728 729725 724725732730724 725 730 735 735 732 732 734 735736732725730 735 740 740 740 735 741745740735735740740740735740 735 730725 725730735740745739738735730730735 735 740 740 73 5 730727 725 725720729 730 716717717720725 724720720720716716718719720720720725725721 72 4 720 720 722 723 724 724725726 724 722 719719718720715715719 720718718720 718717715715718719717 714715 716 718 718 717 717 718 718 715715 720720 7 2 1 722 724 723 723 722 724 721 724 722 716 719718720716 716 720 714 714715 715 716 717715 714715 713 714 717IPF IPF IPF RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 TYSON DRIVE - ROUTE 863 80' RIGHT-OF-WAY DB. 733 PG. 517 SA CO MB MBMB MB LP MBMB LP LP LP LP LP LP LP LP LP OHERBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 INV.=713.35' INV.=713.02' INV.=712.84'INV.=713.22' INV.=713.15' INV.=712.11' INV.=711.96' INV.=712.26' INV.=714.07' INV.=715.04'INV.=714.98' INV.=713.45' INV.=712.78' INV.=712.88'(3)-48" CMP INV.=714.14' C TEL BX TR TR TR TR TR EX. HEADWALL EX. HEADWALL EX. HEADWALL EX. HEADWALL EX. RIP-RAP EX. RIP-RAP EX. RIP-RAP EX. RIP-RAP EX. RIP-RAP EX. CONC. DITCH EX. CONC. DITCH EX. CONC. DITCH EX. HEADWALL EX. CULVERT EX. RIP-RAP EX. RIP-RAP EX. HVAC EX. HVAC TEL BX RD RD RD RD RD RD RD RD RD RD RD TOP=717.34 EX. 1 EX.2 EX.3 EX.4 EX.5 EX.6 EX.7 EX.8 EX.9 EX.10 INV.=716.74' INV.=718.12'12" HDPE12" HDPE12" HDPE WV ACACAC C E TR E AC E SIGN SIGN SIGN LOT 6 STONEWALL INDUSTRIAL PARK DONALD G. SOWERS4.1667 ACRES 2.5000 ACRES MAP #43-19-58 INSTR. #050008976 ZONING - M1 LOT 4 STONEWALL INDUSTRIAL PARK LAKEVILLE CIRCLE LLC C/O TRANFORM DEVELOPMENT 2.6752 ACRES MAP #43-19-58 INSTR. #050008976 ZONING - M1 LOT 7 STONEWALL INDUSTRIAL PARK PERRY FAMILY PARTNERS IV LLC 3.159 ACRES MAP #43-19-59 INSTR. #130000701 ZONING - M1 LOT 7A STONEWALL INDUSTRIAL PARK RESS PROPERTIES LLC 2.000 ACRES MAP #43-19-59A INSTR. #070003537 ZONING - M1 LOT 8-A STONEWALL INDUSTRIAL PARK LOKEY ENTERPRISES LLC 4.100 ACRES MAP #43-19-62 INSTR. #100008447 ZONING - M1 LOT 35 STONEWALL INDUSTRIAL PARK TMME INVESTMENTS LLC 4.7274 ACRES MAP #43-19-61 INSTR. #050018483 ZONING - M1 LOT 14 STONEWALL INDUSTRIAL PARK JONES MANAGEMENT ASSOCIATES 4.1667 ACRES MAP #43-19-29 INSTR. #090000242 ZONING - M1 LOT 35 STONEWALL INDUSTRIAL PARK TMME INVESTMENTS LLC 4.7274 ACRES MAP #43-19-61 INSTR. #050018483 ZONING - M1 WxWxWxINV.=716.02'N47°34'13"W 990.00'S42°25'47"W 660.00' N42°25'47"E 660.00'S47°34'13"E 990.00'75' FRONT YARD SETBACK 25' REAR YARD SETBACK 25' SIDE YARD SETBACK25' SIDE YARD SETBACKWx Wx Wx Wx WxWxWxWxEX. FCSA SANITARY SEWER EASEMENT INSTR. #060014178 EX. 20' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. 20' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. 10' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. 10' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. 10' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. RIP-RAP LOADING DOCK EXPANSION FRONT ADA PARKING DRY POND ADDITION VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 EXISTING CONDITIONS03 C-XP-101.DWG C-XP-101 1" = 60' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-XP-101.DWG, 2/2/2024 3:42 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-XP-101.DWG, 2/2/2024 3:42 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 GRAPHICAL SCALE: 1" = 60' 60 30 0 60 120 180 EXISTING STORM SEWER AS-BUILT SURVEY INFORMATION: 1.THE PROPERTY SHOWN HEREON IS IDENTIFIED AS FREDERICK COUNTY MAP NUMBER 43-19-31 AND IS ZONED M1, UNDER THE FREDERICK COUNTY ZONING ORDINANCE. 2.THIS TOPOGRAPHIC SURVEY WAS COMPLETED UNDER THE DIRECT AND RESPONSIBLE CHARGE OF STANLEY D. HEISER FROM AN ACTUAL AIRBORNE SURVEY AND SUPPLEMENTED WITH A GROUND SURVEY MADE UNDER MY SUPERVISION; THAT THE ORIGINAL AERIAL DATA WAS OBTAINED ON JULY 11, 2022 AND JULY 22, 2022; AND THAT THIS MAP INCLUDING METADATA MEETS MINIMUM ACCURACY STANDARDS UNLESS OTHERWISE NOTED. 3.AERIAL TOPOGRAPHY PREFORMED BY NV5 GEOSPATIAL ON JULY 11, 2022 AND SUPPLEMENTED WITH A GROUND SURVEY BY GORDON ON JULY 22, 2022. 4.COMMITMENT FOR TITLE INSURANCE NOT PROVIDED, THEREFORE ALL UNDERLYING EASEMENTS MAY NOT BE SHOWN HEREON. 5.HORIZONTAL DATUM: NAD 83. 6.VERTICAL DATUM: NAVD 88. VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 EX. CURB & GUTTER 4 5 WxWxLP L P L P LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX. SCUPPER EX. SCUPPER EX. CURB & GUTTER EX. CURB & GUTTER EX CONCRETE EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. RIP-RAP EX. WALK W/STEPS EX. SCUPPER EX. CONC. DUMPSTER PAD EX. HVAC EX. HVAC EX. SCREEN WALL RD RD RD RD RD RD RD RD RD RD RD EX. 6 EX. 7 EX. 8 EX. 9 EX. 10 INV.=716.74' INV.=718.12'12" HDPE12" HDPE12" HDPE 12" HDPE6"PVC 12" HDPE18" RCP EX. CONC. WALKSIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE EX. 6" WATER LINE EX. 8" WATER LINE NO RECORD OF EXISTING EASEMENT SEE UTILITY PLAN AND PLAT OF EASEMENT FOR ESTABLISHMENT OF NEW EASEMENT 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50' EX. 20' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. 10' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 4 7 7 7 7 7 7 7 7 7 1 1 1 2 1 3 4 4 4 5 5 5 5 5 5 5 6 9 9 8 8 9 9 11 5 5 55 13 13 14 15 15 15 15 16 17 5 13 18.04'107.95'3 3 9 9 12 9 9 18 18 7 10 4. 3 3 ' 19 19 19 19 7 7 11 20 14.46' 8 5 11 11 21 7 7 5 7 7 7 722 5 24 24 26 26 GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 DEMOLITION PLAN04 C-CD-101.DWG C-CD-101 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CD-101.DWG, 2/2/2024 3:42 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CD-101.DWG, 2/2/2024 3:42 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 FRONT ADA PARKING DEMOLITION LEGEND DENOTES APPROXIMATE LIMITS OF ASPHALT SURFACE COURSE TO BE REMOVED DENOTES APPROXIMATE LIMITS OF CONCRETE TO BE REMOVED DENOTES APPROXIMATE LIMITS OF LINEAR FEATURES TO BE REMOVED NO DESCRIPTION DEMOLITION KEY REMOVE EXISTING ASPHALT PAVEMENT AND SUBBASE REMOVE EXISTING ASPHALT PAVEMENT SURFACE COURSE WITH A CLEAN EDGE SAWCUT ASPHALT REMOVE EXISTING SIDEWALK REMOVE EXISTING CURB AND GUTTER AND SAWCUT AT NEAREST JOINT REMOVE EXISTING CONCRETE PAVEMENT REMOVE TREE(S) AND/OR SHRUB(S) SALVAGE FIVE (5) HANDICAPPED PARKING SIGNS TO BE REINSTALLED. TWO (2) SIGNS SHALL INDICATE VAN ACCESSIBLE. SIGNS SHOWING LEAST WEAR SHALL BE SALVAGED. DENOTES REMOVAL OF PAVEMENT MATERIALS 1 2 3 4 5 6 7 8 9 10 11 REMOVE PORTION OF EXISTING WATER LINE AND ASSOCIATED STRUCTURES. PROTECT EXISTING VALVE. REMOVE EXISTING FIRE HYDRANT REMOVE HVAC (SEE MECHANICAL DRAWINGS) REMOVE PORTION OF EXISTING STORM SEWER REMOVE EXISTING STORM SEWER MANHOLE REMOVE EXISTING GRATE INLET REMOVE EXISTING SIGN TREE REMOVAL 12 13 14 15 16 17 REMOVE HVAC CONCRETE PAD. RESTORE GRADE AND STABILIZE WITH GRASS PROTECT EXISTING LIGHT POLE18 REMOVE EXISTING HEADER CURB DEMOLITION NOTES: 1.THE DEMOLITION PLAN IS A GENERAL GUIDE OF WHAT ITEMS NEED TO BE DEMOLISHED. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY ALL ITEMS THAT REQUIRE DEMOLITION TO COMPLETE THE PROPOSED CONSTRUCTION. 2.CONTRACTOR SHALL PROTECT ALL EXISTING BUILDINGS AND FEATURES NOT SCHEDULED FOR DEMOLITION FROM DAMAGE DUE TO DEMOLITION PROCEDURES. 3.THIS PLAN INCLUDES EROSION & SEDIMENT CONTROLS THAT ARE REQUIRED TO BE PLACED PRIOR TO ANY DEMOLITION OR DISTURBANCE. FOLLOWING COMPLETION OF DEMOLITION WORK, CONTRACTOR SHALL MODIFY AND ADD EROSION AND SEDIMENT CONTROLS AS SPECIFIED ON THE PLAN ENTITLED 'EROSION AND SEDIMENT CONTROL PLAN PHASE 1' ON SHEET 20, OR AS NECESSARY TO PREVENT SILT AND CONTAMINATED RUNOFF FROM LEAVING THE SITE. 4.ALL MATERIAL FROM DEMOLITION NOT IDENTIFIED FOR REUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF PROPERLY. 5.CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING ROADS AND/OR UTILITIES WHICH OCCUR AS A RESULT OF PROJECT CONSTRUCTION WITHIN OR CONTIGUOUS TO THE LIMITS OF CLEARING AND GRADING. 6.REMOVAL OF UTILITIES INCLUDES REMOVAL OF ALL ASSOCIATED APPURTENANCES. 7.PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING THE EXACT HORIZONTAL AND VERTICAL LOCATIONS OF THE EXISTING UTILITIES WHERE THE PROPOSED IMPROVEMENTS CROSS OR CONNECT TO IDENTIFY IF CONFLICTS WILL EXIST. THE CONTRACTOR SHALL NOTIFY THE OWNER AND ENGINEER IF CONFLICTS ARE FOUND. 8.PROTECT AND SUPPORT ALL EXISTING UTILITIES TO REMAIN DURING CONSTRUCTION. REMOVE ALL EXISTING SIGNS AND LIGHT POLES ALONG DEMOLISHED ROADWAY AND PARKING AREAS. 9.PROTECT ALL HARDSCAPES TO REMAIN WITHIN WORK ZONE. 10.DEMOLISH ALL RIGID PAVEMENTS (SIDEWALKS, CURB AND GUTTER) TO THE NEAREST JOINT. 11.BOLD ITEMS TO BE REMOVED/SALVAGED AS INDICATED ON THE PLANS. 12.REMOVE AND RELOCATE ALL LIGHT POLE CONDUITS AS NECESSARY TO AVOID PROPOSED IMPROVEMENTS. 13.PROTECT ALL EXISTING LANDSCAPED FEATURES TO REMAIN. SEE EROSION AND SEDIMENT CONTROL PLAN PHASE 1 ON SHEET 20. 14.EXISTING FREDERICK WATER FACILITIES TO BE REMOVED ARE TO BE FURNISHED TO A FREDERICK WATER INSPECTOR. 15.REMOVE TREES, BRUSHES AND DELETERIOUS MATERIALS FROM STORMWATER EMBANKMENT IN ACCORDANCE WITH GEOTECH REPORT. REMOVE EXISTING ROOF LEADER CONNECTION FROM BUILDING TO STORM DRAIN19 REMOVE TREE AND STUMP AT PIPE OUTLET20 PROTECT/MAINTAIN ROOF LEADER FOR FUTURE CONNECTION21 REMOVE EXISTING RIP RAP22 REMOVE EXISTING STORM INLET/OUTLET STRUCTURE23 MATCH LINE SEE SHEET 05 CLEAR TREES AND BRUSH INSIDE LIMITS OF DRY POND AND REMOVE ROOTS FROM POND EMBANKMENT TO TOE OF SLOPE IN ACCORDANCE WITH GEOTECH REPORT 24 REMOVE PORTION OF EX. 24" CMP PIPE25 DENOTES APPROXIMATE LIMITS OF TREES AND BRUSH REMOVAL REMOVE CONCRETE FLUME26 DENOTES APPROXIMATE LIMITS OF ROOT PRUNING AND REMOVAL WITHIN POND EMBANKMENT SA CO EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. RIP-RAP EX. EDGE OF PAVEMENT INV.=716.74' INV.=718.12' 18" RCP SIGN INV.=716.02'N47°34'13"W 990.00'25' SIDE YARD SETBACK20 7 22 24 24 24 24 26 26 26 26 IPF INV.=713.22' INV.=713.15' INV.=712.11' INV.=711.96' INV.=712.26' INV.=714.98' INV.=713.45' INV.=712.78' INV.=712.88'24" CMP(3)-48" CMP INV.=714.14' EX. EDGE OF PAVEMENT EX. EDGE OF PAVEMENT EX. CONC.EX. CURB & GUTTEREX. SCUPPER EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. ASPHALT EX. ASPHALT EX. CONCRETE EX. RIP-RAP EX. CURB & GUTTER EX. EDGE OF PAVEMENT TOP=717.34 EX. 1 EX. 2 EX. 3 STONEWALL INDUSTRIAL PARK 75' FRONT YARD SETBACK Wx Wx Wx EX. FCSA SANITARY SEWER EASEMENT INSTR. #060014178 EX. 20' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. RIP-RAP 25 24 24 24 24 26 26 26 26 4.38' 3.09' VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 DRY POND DEMOLITION PLAN05 C-CD-101.DWG C-CD-101 1" = 20' SBH BTV BTV CEKGordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CD-101.DWG, 2/2/2024 3:42 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 MATCH LINE SEE SHEET 04 MATCH LINE SEE THIS SHEET MATCH LINE SEE THIS SHEET DEMOLITION LEGEND DENOTES APPROXIMATE LIMITS OF ASPHALT SURFACE COURSE TO BE REMOVED DENOTES APPROXIMATE LIMITS OF CONCRETE TO BE REMOVED DENOTES APPROXIMATE LIMITS OF LINEAR FEATURES TO BE REMOVED NO DESCRIPTION DEMOLITION KEY REMOVE EXISTING ASPHALT PAVEMENT AND SUBBASE REMOVE EXISTING ASPHALT PAVEMENT SURFACE COURSE WITH A CLEAN EDGE SAWCUT ASPHALT REMOVE EXISTING SIDEWALK REMOVE EXISTING CURB AND GUTTER AND SAWCUT AT NEAREST JOINT REMOVE EXISTING CONCRETE PAVEMENT REMOVE TREE(S) AND/OR SHRUB(S) SALVAGE FIVE (5) HANDICAPPED PARKING SIGNS TO BE REINSTALLED. TWO (2) SIGNS SHALL INDICATE VAN ACCESSIBLE. SIGNS SHOWING LEAST WEAR SHALL BE SALVAGED. DENOTES REMOVAL OF PAVEMENT MATERIALS 1 2 3 4 5 6 7 8 9 10 11 REMOVE PORTION OF EXISTING WATER LINE AND ASSOCIATED STRUCTURES. PROTECT EXISTING VALVE. REMOVE AND SALVAGE EXISTING FIRE HYDRANT REMOVE HVAC (SEE MECHANICAL DRAWINGS) REMOVE PORTION OF EXISTING STORM SEWER REMOVE EXISTING STORM SEWER MANHOLE REMOVE EXISTING GRATE INLET REMOVE EXISTING SIGN TREE REMOVAL 12 13 14 15 16 17 REMOVE HVAC CONCRETE PAD. RESTORE GRADE AND STABILIZE WITH GRASS PROTECT EXISTING LIGHT POLE18 REMOVE EXISTING HEADER CURB DEMOLITION NOTES: 1.THE DEMOLITION PLAN IS A GENERAL GUIDE OF WHAT ITEMS NEED TO BE DEMOLISHED. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY ALL ITEMS THAT REQUIRE DEMOLITION TO COMPLETE THE PROPOSED CONSTRUCTION. 2.CONTRACTOR SHALL PROTECT ALL EXISTING BUILDINGS AND FEATURES NOT SCHEDULED FOR DEMOLITION FROM DAMAGE DUE TO DEMOLITION PROCEDURES. 3.THIS PLAN INCLUDES EROSION & SEDIMENT CONTROLS THAT ARE REQUIRED TO BE PLACED PRIOR TO ANY DEMOLITION OR DISTURBANCE. FOLLOWING COMPLETION OF DEMOLITION WORK, CONTRACTOR SHALL MODIFY AND ADD EROSION AND SEDIMENT CONTROLS AS SPECIFIED ON THE PLAN ENTITLED 'EROSION AND SEDIMENT CONTROL PLAN PHASE 1' ON SHEET 20, OR AS NECESSARY TO PREVENT SILT AND CONTAMINATED RUNOFF FROM LEAVING THE SITE. 4.ALL MATERIAL FROM DEMOLITION NOT IDENTIFIED FOR REUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF PROPERLY. 5.CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING ROADS AND/OR UTILITIES WHICH OCCUR AS A RESULT OF PROJECT CONSTRUCTION WITHIN OR CONTIGUOUS TO THE LIMITS OF CLEARING AND GRADING. 6.REMOVAL OF UTILITIES INCLUDES REMOVAL OF ALL ASSOCIATED APPURTENANCES. 7.PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING THE EXACT HORIZONTAL AND VERTICAL LOCATIONS OF THE EXISTING UTILITIES WHERE THE PROPOSED IMPROVEMENTS CROSS OR CONNECT TO IDENTIFY IF CONFLICTS WILL EXIST. THE CONTRACTOR SHALL NOTIFY THE OWNER AND ENGINEER IF CONFLICTS ARE FOUND. 8.PROTECT AND SUPPORT ALL EXISTING UTILITIES TO REMAIN DURING CONSTRUCTION. REMOVE ALL EXISTING SIGNS AND LIGHT POLES ALONG DEMOLISHED ROADWAY AND PARKING AREAS. 9.PROTECT ALL HARDSCAPES TO REMAIN WITHIN WORK ZONE. 10.DEMOLISH ALL RIGID PAVEMENTS (SIDEWALKS, CURB AND GUTTER) TO THE NEAREST JOINT. 11.BOLD ITEMS TO BE REMOVED/SALVAGED AS INDICATED ON THE PLANS. 12.REMOVE AND RELOCATE ALL LIGHT POLE CONDUITS AS NECESSARY TO AVOID PROPOSED IMPROVEMENTS. 13.PROTECT ALL EXISTING LANDSCAPED FEATURES TO REMAIN. SEE EROSION AND SEDIMENT CONTROL PLAN PHASE 1 ON SHEET 20. 14.EXISTING FREDERICK WATER FACILITIES TO BE REMOVED ARE TO BE FURNISHED TO A FREDERICK WATER INSPECTOR. 15.REMOVE TREES, BRUSHES AND DELETERIOUS MATERIALS FROM STORMWATER EMBANKMENT IN ACCORDANCE WITH GEOTECH REPORT. REMOVE EXISTING ROOF LEADER CONNECTION FROM BUILDING TO STORM DRAIN19 REMOVE TREE AND STUMP AT PIPE OUTLET20 PROTECT/MAINTAIN ROOF LEADER FOR FUTURE CONNECTION21 REMOVE EXISTING RIP RAP22 REMOVE EXISTING STORM INLET/OUTLET STRUCTURE23 CLEAR TREES AND BRUSH INSIDE LIMITS OF DRY POND AND REMOVE ROOTS FROM POND EMBANKMENT TO TOE OF SLOPE IN ACCORDANCE WITH GEOTECH REPORT 24 REMOVE PORTION OF EX. 24" CMP PIPE25 DENOTES APPROXIMATE LIMITS OF TREES AND BRUSH REMOVAL REMOVE CONCRETE FLUME26 DENOTES APPROXIMATE LIMITS OF ROOT PRUNING AND REMOVAL WITHIN POND EMBANKMENT VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 LP L P L P LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX CONCRETE EX. ASPHALT EX. SCREEN WALL RD RD RD RD EX. 6 EX. 10 12" HDPE6"PVC 12" HDPE18" RCP SIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50' EX. 20' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. 10' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 FFE = 724.95' 1 1 1 2 2 29 12 3 3 19 4 28 5 6 87 9 9 10 11 13 14 18 15 26 15 3 19 20 21 21 22 22 22 22 23 25 27 26 27 5 5 24 3 11 11 11 28 16 4 16 8 16 17 17 5 22 29 30 EX. CURB & GUTTER 6 77 12 5 GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 SITE PLAN06 C-CS-101.DWG C-CS-101 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-101.DWG, 2/2/2024 3:42 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-101.DWG, 2/2/2024 3:42 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 FRONT ADA PARKING SITE PLAN NOTES: 1.SEE SHEETS 15 THROUGH 18 FOR SITE DETAILS. 2.SEE SHEET 01 FOR LEGENDS AND ABBREVIATIONS. 3.SEE EXISTING CONDITIONS PLAN ON SHEET 03 FOR LOCATIONS OF LOADING DOCK EXPANSION AND FRONT ADA PARKING WITH RESPECT TO THE EXISTING BUILDING. 4.SEE STRUCTURAL DRAWINGS FOR DESIGN OF RETAINING WALLS. 5.FOR ROCK OUTLET PROTECTION DETAIL SEE SHEET 24. 6.SEE SHEET 07 FOR DIMENSIONING AND JOINT LAYOUT. 7.NO NEW MONUMENT SIGNS ARE PROPOSED WITH THIS PROJECT. 8.TRASH CONTAINERS SHALL BE CONTAINED WITHIN A COMPLETELY ENCLOSED FACILITY. THE ENCLOSURE SHALL CONSIST OF A SIX FOOT OPAQUE FENCE OR WALL AND AN OPAQUE GATE. PAVEMENT LEGEND NO.DESCRIPTION SITE IMPROVEMENTS KEY PR. CONCRETE SIDEWALK1 2 3 4 5 6 7 8 9 10 11 12 DETAIL PR. LIGHT DUTY ASPHALT PAVEMENT PR. HEAVY DUTY CONCRETE PR. CURB AND GUTTER; CG-6 PR. CURB AND GUTTER; CG-6R PR. ADA RAMP; CG-12 REINSTALL SALVAGED HANDICAPPED PARKING SIGN PR. LOADING DOCK RETAINING WALLS W/HANDRAILS (SEE STRUCTURAL AND ARCHITECTURAL DRAWINGS) PR. 4,250 SF LOADING DOCK (SEE ARCHITECTURAL DRAWINGS) PR. TRUCK BAYS (SEE ARCHITECTURAL DRAWINGS) ADA PARKING SPACES A 17 J 15 E 15 B 15 B 15 D 17 13 PR. DUMPSTER PAD (SEE NOTE 8 THIS SHEET) 14 PR. CONCRETE DRIVE IN RAMP D 15 15 PR. BOLLARDS (TYP.) 16 PR. CURB TRANSITION A 11 17 PR. WHEEL STOP PR. WOODEN SCREENING FENCE18 A 18 PR. HEAVY DUTY ASHPALT PAVEMENT19 C 15 ROCK OUTLET PROTECTION (SEE E&S DETAILS ON SHEET 24)20 TRANSITION HEAVY DUTY ASPHALT TO HEAVY DUTY CONCRETE21 TRANSITION HEAVY DUTY ASPHALT TO LIGHT DUTY ASPHALT22 TRANSITION HEAVY DUTY ASPHALT TO EXISTING ASPHALT PAVEMENT23 TRANSITION HEAVY DUTY ASPHALT TO EXISTING CONCRETE PAVEMENT24 H 15 CONCRETE STEPS WITH 6" RISER HEIGHT (SEE GRADING PLAN)25 D 18 F 15 G 15 H 15 PR. FIRE LANE SIGN; TYPE A26 PR. FIRE LANE SIGN; TYPE C27 B, C 18 B, C 18 LIGHT DUTY ASPHALT PAVEMENT DUMPSTER PAD CONCRETE (SEE IMPROVEMENTS KEY) HEAVY DUTY ASPHALT PAVEMENT CURB AND GUTTER; CG-6R PR. CURB; CG-2 I 15 B 15 H 24 28 REINSTALL SALVAGED HANDICAPPED VAN PARKING SIGN E 18 STRIPE PARKING SPACES WITH 4" WIDE WHITE STRIPE29 STRIPE AREA AROUND DUMPSTER WITH 4" WIDE YELLOW STRIPES 2' ON CENTER TURNED 45 DEGREES TO THE ADJACENT PARKING SPACES 30 VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3WWWLP L P L P LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX CONCRETE EX. ASPHALT EX. SCREEN WALL RD RD RD RD EX. 6 EX. 10 12" HDPE6"PVC 12" HDPE18" RCP SIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50' EX. 20' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. 10' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 FFE = 724.95' 9 0 . 0 0 1 2 R 3 'R15'9 0 . 0 0 2 9' 9'8'9'43.26'107.95'76'11.5'12'12.5'12' 39.02'67.81' 14.5' 50.15' 50.65'5'8.4'8.4'8.4'60' 60' 2' 5'3.78'22.27'41.72'16.8'16.8'3'53.28'22.5' 5' 61. 6 8 ' 22.82'13.64'3'18'8.4'5'60' 24'25'4. 7 9 '12'12'22.28'11.02'9.5'13.42'13.43'12.3'14.29'3'4.07'5'9' R3 'R3'2' EX. CURB & GUTTER 9 0 . 0 0 1 1 12.05'5.01'9.5'18'8' 8.28' 5' 6.72' 9.5' GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 DIMENSIONING AND JOINT LAYOUT PLAN07 C-CS-102.DWG C-CS-102 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-102.DWG, 2/2/2024 3:42 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-102.DWG, 2/2/2024 3:42 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 FRONT ADA PARKING DIMENSIONING AND JOINT NOTES: 1.SEE SHEET 16 FOR JOINT AND JOINT SEALANT DETAILS. 2.SEE EXISTING CONDITIONS PLAN ON SHEET 03 FOR LOCATIONS OF LOADING DOCK EXPANSION AND FRONT ADA PARKING WITH RESPECT TO THE EXISTING BUILDING. 3.SEE SITE PLAN ON SHEET 06 FOR PAVEMENT PLAN AND SHEET 15 FOR PAVEMENT CROSS SECTION DETAILS AND TRANSITIONS. PAVEMENT LEGEND CONSTRUCTION JOINT (CJ) NO.DESCRIPTION JOINT KEY CONSTRUCTION JOINT1 2 DETAIL EXPANSION JOINT A, B 16 A, B 16 EXPANSION JOINT (EJ) VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3725730 735 740 735740740740735740 735 730725 725730735735 725720716720725725721 72 4 720 720 722 723 724 724725 726 724 722 719717LP L P L P LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX CONCRETE EX. ASPHALT EX. SCREEN WALL RD RD RD RD EX. 6 EX. 10 12" HDPE6"PVC 12" HDPE18" RCP SIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50' EX. 20' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. 10' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 WWW8 7 9 RD7 RD6 RD5 RD4 RD3 TD6 TD5 TD4 TD3 TD2 RD1 TD1 RD2 T4 8A 8B T1 T2 T3 720725730 721721 722722722 723723724726727728729731 732 733 72372422.6 23.0 23 33 TC 21 82 TC 19.6 19.9 23.1 22.8 23.3 24.1 25.0 27.3 26.8 24.9 20.0 20.4 20 50 TC 20 45 TC 20 88 TC 21 41 TC 22 71 TC 22 89 TC 20.2 20.5 23 93 24 56 25 29 25 71 24 25 23 72 23 69 23 59 23 57 23 04 22 10 EP 22 10 22 10 22 10 23 46 24 95 24 95 25 20 23 51 22 64 TC 22 10 20 95 BW 21 49 21 48 21 25 23 05 4.1% 2.1% 4.6% 4.6% 2. 7 % 3.6% 2.4 % 3.1%2.0%5.6%21 48 21 48 22 10 21 48 23 79 23 79 TC 23 69 TC 24 02 TC 23 36 24 34 24 75 24 93 24 95 24 95 24 28 24 27 24 11 TC 2.1% 20 91 20 91 20 91 20 91 20 91 20 95 BW 20 95 BW 20 95 BW 20 95 EP 0.0%22 62 TW 25 45 TW 23 14 TW 25 45 TW 23 01 TC 24 95 24 95 25 89 25 15 25 95 26 13 EP 25 89 EP 26 41 TC2696 TC 22 37 23 68 24 37 23 54 EP 24 95 EP 24 95 24 85 25 29 TC 24 33 TC2313 TC 21 48 EP 20 08 20 95 BW 21 50 EP STAIR TOP = 20.55' STAIR BOTTOM = 20.05' STAIR TOP = 21.13' STAIR BOTTOM = 20.63' STAIR TOP = 21.72' STAIR BOTTOM = 21.22' STAIR TOP = 22.80' STAIR BOTTOM = 22.30' 22 73 TC 725 730 726 727 728 729 731 732 720 721 722 25 30 TC 721 722 15 60 15 77 15 92 7167167177187207167167177177187187190.4%0.4%16 02 22 12 EP 24 95 24 01 TW2357 TW 72071771871972121 15 24 95 725 FFE = 724.95' LCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LC G LCGLCG LCG LCGLCG LCG LCG LC G LCG LCG LCG LCGLCG LCG LCG LCG LCG LCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCG A A CONSTRUCT AND VERIFY IMPERMEABLE POND LINER IN ACCORDANCE WITH THE OCTOBER 16TH, 2023 GEOTECHNICAL ENGINEERING REPORT BY ECS MID-ATLANTIC SIGNED AND SEALED BY SENIOR ENGINEERING GEOLOGIST, NICHOLAS C. BASS. DETAIL 'B' ON SHEET 17 RECONSTRUCT CONCRETE SCUPPER TO MATCH GRADE SHOWN AND EXTEND SCUPPER TO TOE OF SLOPE. NEW SCUPPER TO MATCH EXISTING SUPPER DIMENSIONS FOR DEPTH AND WIDTH. RECONSTRUCT CONCRETE SCUPPER TO MATCH GRADE SHOWN AND EXTEND SCUPPER TO TOE OF SLOPE. NEW SCUPPER TO MATCH EXISTING SUPPER DIMENSIONS FOR DEPTH AND WIDTH. 2 YR. W.S.E = 716.00' 10 YR. W.S.E = 716.50' 100 YR. W.S.E = 717.00' L P GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 GRADING AND DRAINAGE PLAN08 C-CG-101.DWG C-CG-101 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CG-101.DWG, 2/2/2024 3:42 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CG-101.DWG, 2/2/2024 3:42 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 REAR ADA PARKING GRADING NOTES: 1.VERIFY EXISTING TOPOGRAPHY AND NOTIFY ENGINEER IMMEDIATELY IF ELEVATIONS ON THE PLAN DO NOT MATCH ELEVATIONS MEASURED IN THE FIELD. 2.MATCH EXISTING LINE AND GRADE AT CONNECTION TO EXISTING PAVEMENTS. 3.SEE DETAIL 'B' ON SHEET 17 FOR CROSS SECTIONS OF PROPOSED LOADING DOCK EXPANSION. 2.0% 25 00 25 00 25 00 25 00 TC FL EP GRADING LEGEND PR. SLOPE DIRECTION OF FLOW ARROW PR. GROUND SPOT SHOT PR. TOP OF CURB ELEVATION PR. FLOW LINE ELEVATION PR. EDGE OF PAVEMENT ELEVATION EX. SPOT SHOT ELEVATION25.0 FRONT ADA PARKING 25 00 TW PR. TOP OF WALL ELEVATION CURB AND GUTTER; CG-6R CURB AND GUTTER; CG-6 TRANSITION GUTTER MATCH LINE SEE SHEET 09 725 725730735 730 727725 725720729 7167177177207 2 5 720 719719718717SA CO EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. EDGE OF PAVEMENT 18" RCP SIGN INV.=716.02'N47°34'13"W 990.00'25' SIDE YARD SETBACK7 20 08 15 39 15 60 15 77 15 92 15 23 15 02 14 88 14 74 14 59 7157157167167177177187187167167177177187187207167167177177187187190.4%0.4%0.4%0.4%16 02 720717718719721LCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCG LCG LCG CONSTRUCT AND VERIFY IMPERMEABLE POND LINER IN ACCORDANCE WITH THE OCTOBER 16TH, 2023 GEOTECHNICAL CONSTRUCT AND VERIFY IMPERMEABLE POND LINER IN ACCORDANCE WITH THE OCTOBER 16TH, 2023 GEOTECHNICAL ENGINEERING REPORT BY ECS MID-ATLANTIC SIGNED AND SEALED BY SENIOR ENGINEERING GEOLOGIST, NICHOLAS C. BASS. CONSTRUCT AND VERIFY IMPERMEABLE POND LINER IN ACCORDANCE WITH THE OCTOBER 16TH, 2023 GEOTECHNICAL ENGINEERING REPORT BY ECS MID-ATLANTIC SIGNED AND SEALED BY SENIOR ENGINEERING GEOLOGIST, NICHOLAS C. BASS. RECONSTRUCT CONCRETE SCUPPER TO MATCH GRADE SHOWN AND EXTEND SCUPPER TO TOE OF SLOPE. NEW SCUPPER TO MATCH EXISTING SUPPER DIMENSIONS FOR DEPTH AND WIDTH. RECONSTRUCT CONCRETE SCUPPER TO MATCH GRADE SHOWN AND EXTEND SCUPPER TO TOE OF SLOPE. NEW SCUPPER TO MATCH EXISTING SUPPER DIMENSIONS FOR DEPTH AND WIDTH. RECONSTRUCT CONCRETE SCUPPER TO MATCH GRADE SHOWN AND EXTEND SCUPPER TO TOE OF SLOPE. NEW SCUPPER TO MATCH EXISTING SUPPER DIMENSIONS FOR DEPTH AND WIDTH. RECONSTRUCT CONCRETE SCUPPER TO MATCH GRADE SHOWN AND EXTEND SCUPPER TO TOE OF SLOPE. NEW SCUPPER TO MATCH EXISTING SUPPER DIMENSIONS FOR DEPTH AND WIDTH. 2 YR. W.S.E = 716.00' 10 YR. W.S.E = 716.50' 100 YR. W.S.E = 717.00' 2 YR. W.S.E = 716.00' 10 YR. W.S.E = 716.50' 100 YR. W.S.E = 717.00'724720720720716716718719720715715719718718 720 718717715715718719717 714 715 716 718 714 714 715 715 716 717 715 714 715 713 714 IPF INV.=713.15' INV.=712.11' INV.=711.96' INV.=712.26' INV.=714.98' INV.=713.45' INV.=712.78' INV.=712.88'24" CMP(3)-48" CMP INV.=714.14' EX. EDGE OF PAVEMENT EX. EDGE OF PAVEMENT EX. CONC.EX. CURB & GUTTEREX. ASPHALT EX. ASPHALT EX. CONCRETE EX. RIP-RAP EX. CURB & GUTTER EX. EDGE OF PAVEMENT TOP=717.34 EX. 1 EX. 2 EX. 3 STONEWALL INDUSTRIAL PARK 75' FRONT YARD SETBACK Wx Wx Wx EX. FCSA SANITARY SEWER EASEMENT INSTR. #060014178 EX. 20' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. RIP-RAP 14 59 14 46 14 28 14 01 13 76 13 62 13 43 13 20 14 001400715 7157147147167167177177187187157157167167177177187187157147167177180.4%0.4%0.4%0.4%0.4%17 00 17 001700 17 001700 17 00 7 1 8 LCG LCG LCG LCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCG LCG LCG LCG 30' WIDE EMERGENCY SPILLWAY ELEV. = 717.00' 12.00' 12' WIDE ENDWALL SEE DETAIL 'A' ON SHEET 14 CONSTRUCT AND VERIFY IMPERMEABLE POND LINER IN ACCORDANCE WITH THE OCTOBER 16TH, 2023 GEOTECHNICAL ENGINEERING REPORT BY ECS MID-ATLANTIC SIGNED AND SEALED BY SENIOR ENGINEERING GEOLOGIST, NICHOLAS C. BASS. CONSTRUCT AND VERIFY IMPERMEABLE POND LINER IN ACCORDANCE WITH THE OCTOBER 16TH, 2023 GEOTECHNICAL ENGINEERING REPORT BY ECS MID-ATLANTIC SIGNED AND SEALED BY SENIOR ENGINEERING GEOLOGIST, NICHOLAS C. BASS. LINE CULVERT WITH CONTROLLED LOW STRENGTH MATERIAL PER DETAIL 'B' ON SHEET 17 AS REQUIRED BY GEOTECHNICAL ENGINEER NICHOLAS C. BASS EC-3 MATTING RECONSTRUCT CONCRETE SCUPPER TO MATCH GRADE SHOWN AND EXTEND SCUPPER TO TOE OF SLOPE. NEW SCUPPER TO MATCH EXISTING SUPPER DIMENSIONS FOR DEPTH AND WIDTH. RECONSTRUCT CONCRETE SCUPPER TO MATCH GRADE SHOWN AND EXTEND SCUPPER TO TOE OF SLOPE. NEW SCUPPER TO MATCH EXISTING SUPPER DIMENSIONS FOR DEPTH AND WIDTH. RECONSTRUCT CONCRETE SCUPPER TO MATCH GRADE SHOWN AND EXTEND SCUPPER TO TOE OF SLOPE. NEW SCUPPER TO MATCH EXISTING SUPPER DIMENSIONS FOR DEPTH AND WIDTH. RECONSTRUCT CONCRETE SCUPPER TO MATCH GRADE SHOWN AND EXTEND SCUPPER TO TOE OF SLOPE. NEW SCUPPER TO MATCH EXISTING SUPPER DIMENSIONS FOR DEPTH AND WIDTH. RECONSTRUCT CONCRETE SCUPPER TO MATCH GRADE SHOWN AND EXTEND SCUPPER TO TOE OF SLOPE. NEW SCUPPER TO MATCH EXISTING SUPPER DIMENSIONS FOR DEPTH AND WIDTH. 2 YR. W.S.E = 716.00' 10 YR. W.S.E = 716.50' 100 YR. W.S.E = 717.00' VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 DRY POND GRADING AND DRAINAGE PLAN09 C-CG-101.DWG C-CG-101 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CG-101.DWG, 2/2/2024 3:42 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CG-101.DWG, 2/2/2024 3:42 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 GRADING NOTES: 1.VERIFY EXISTING TOPOGRAPHY AND NOTIFY ENGINEER IMMEDIATELY IF ELEVATIONS ON THE PLAN DO NOT MATCH ELEVATIONS MEASURED IN THE FIELD. 2.MATCH EXISTING LINE AND GRADE AT CONNECTION TO EXISTING PAVEMENTS. 3.DRY POND SIDE SLOPES SHALL BE A MAXIMUM OF 3:1. 4.EXECUTE THE WORK FOR THE STORMWATER POND EMBANKMENT RECONSTRUCTION AND POND LINER IN ACCORDANCE WITH THE RECOMMENDATIONS PROVIDED IN THE OCTOBER 16TH, 2023 GEOTECHNICAL ENGINEERING REPORT BY ECS MID-ATLANTIC SIGNED AND SEALED BY SENIOR ENGINEERING GEOLOGIST NICHOLAS C. BASS. 5.SEE CULVERT MODIFICATION DETAIL 'B' ON SHEET 14. 6.SEE CULVERT PROFILE ON SHEET 12. 2.0% 25 00 25 00 25 00 25 00 TC FL EP GRADING LEGEND PR. SLOPE DIRECTION OF FLOW ARROW PR. GROUND SPOT SHOT PR. TOP OF CURB ELEVATION PR. FLOW LINE ELEVATION PR. EDGE OF PAVEMENT ELEVATION EX. SPOT SHOT ELEVATION25.0 CURB AND GUTTER; CG-6R CURB AND GUTTER; CG-6 25 00 TW PR. TOP OF WALL ELEVATION TRANSITION GUTTER MATCH LINE SEE SHEET 08 MATCH LINE SEE THIS SHEET MATCH LINE SEE THIS SHEET VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 LP L P L P LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX CONCRETE EX. ASPHALT EX. SCREEN WALL RD RD RD RD EX. 6 EX. 10 12" HDPE6"PVC 12" HDPE18" RCP SIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50' EX. 20' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. 10' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 WWW8 7 9 RD7 RD6 RD5 RD4 RD3 TD6 TD5 TD4 TD3 TD2 RD1 TD1 RD2 T4 8A 8B T1 T2 T3 FFE = 724.95' 1 7 21 2 2 3 5 6 4 8 3 8 11 12 9 9 16 17 16 18 15 15 15 15 15 15 10 19 15 20 20 20 20 13 LOCATE EX. ROOF LEADER AND TIE INTO STRUCTURE 8 AS NECESSARY 17 13 13 13 14 14 13 CONTRACTOR SHALL CONFIRM EXISTING WATER MAIN IS RESTRAINED PER VALVE RESTRAINT REQUIREMENTS, IF NOT CONTRACTOR SHALL INSTALL RESTRAINTS ON THE EXISTING WATERMAIN SEE PLAT OF EASEMENT FOR CREATION OF 20' FREDERICK WATER EASEMENT 18 12 14 14 14 14 11 GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 UTILITY PLAN10 C-CU-101.DWG C-CU-101 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-101.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-101.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 A 12 A 12 C, D 12 B, C 12 C 12 D 13 A, B 12 D 13 C, F 13 UTILITY NOTES: 1.SEE SHEET 11 FOR WATER MAIN PROFILE AND DETAILS. 2.SEE SHEETS 12 AND 13 FOR STORM DRAIN PROFILES, COMPUTATIONS, AND DETAILS. NO.DESCRIPTION UTILITY KEY PR. CONNECTION TO 8" WATER MAIN; EXTEND WATER LINE FROM EXISTING VALVE TO NEW TEE1 2 3 4 5 6 7 8 9 10 11 12 DETAIL 13 14 15 16 PR. 8" CL 52 DIP WATER MAIN PR. 6" CL 52 DIP FIRE HYDRANT LATERAL PR. FIRE HYDRANT PR. 8" TO 6" REDUCER PR. 6" VALVE PR. 8"X8"X6" TEE; 1-8" VALVE; 1-6" VALVE PR. FREDERICK WATER 20' WATER LINE EASEMENT PR. 18" ADS NYLOPAST STRUCTURE; H-20 RATED SOLID TOP PR. ROOF DRAIN CONNECTION PR. 12" HDPE STORM PIPE PR. 24" HDPE STORM PIPE PR. 6" PVC PR. 8" TRENCH DRAIN. SEE TRENCH DRAIN PROFILE SHEET 12 PR. 18" HDPE STORM PIPE PR. 18" ADS NYLOPLAST STRUCTURE; GRATE TOP; CONNECT EXISTING ROOF LEADER 17 18 EX. 12" STORM PIPE TO REMAIN EX. ROOF LEADER TO REMAIN 19 20 PR. 4' VDOT STORM MANHOLE A, B 13 PR. FIRE HYDRANT21 PR. 8" PVC MIN4' COVERMIN4' COVER10+00=8" CONNECTION TO EX. 8" VALVE1-8"X8"X6" TEE;1-8" VALVE; 1-6" VALVE6" FH-1 CONNECTIONINV.=716.5611+39.48=45° HORIZONTAL BENDINV.=717.5412+01.64=1-8" T0 6" REDUCERINV.=718.6312+02.64=1-6" VALVEINV.=718.6412+09.64=FH-2INV.=718.77EX. GRADE 1.5' MIN. CLEAR UNDER STORM PR. GRADE 201.64' OF 8" CL 52 DIP 8.00' OF 6" CL 52 DIP PUBLIC OWNERSHIP 4' COVEREX. GRADE PR. GRADE 9.82' OF 6" CL 52 DIP 10+00=10+00 (8" WATERMAIN)1-8"X8"X6" TEE;1-8" VALVE; 1-6" VALVEINV.=716.6510+09.82=FH-1INV.=717.24PUBLIC OWNERSHIP730735740720721724720723724725726724722LPLPEX.6EX.10W10+10 10+00 12+1010+0011+0012+00725721724720720722723722LPLPEX.6SIGN10+1010+0010+00 VI R G I N I A S T A T E G R I D N O R T H - N A D 8 3 VI R G I N I A S T A T E G R I D N O R T H - N A D 8 3 WATER MAIN PROFILE AND UTILITY DETAILS11 C-CU-201.DWG C-CU-201 1" = 50' 1" = 5' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-201.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-201.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 FIRE HYDRANTANOT TO SCALE GATE VALVEBNOT TO SCALE RESTRAINED JOINTS FOR VALVES AND REDUCERSCNOT TO SCALE RESTRAINED JOINTS FOR TEES AND BENDSDNOT TO SCALE WATERMAIN CONNECTION TO FH-2 WATERMAIN TO FH-1 WATER NOTES: 1.ALL WATER MATERIALS, APPURTENANCES, AND INSTALLATION SHALL BE IN ACCORDANCE WITH THE LATEST VERSION OF THE "WATER AND SEWER STANDARDS AND SPECIFICATIONS FOR FREDERICK COUNTY". SEE FREDERICK WATER CONSTRUCTION NOTES ON SHEET 02. 2.DUCTILE IRON PIPE SHALL CONFORM TO THE REQUIREMENTS OF AWWA STANDARD C151. THE PIPE SHALL BE CEMENT LINED IN ACCORDANCE WITH AWWA STANDARD C104. UNLESS OTHERWISE SPECIFIED, THE PIPE SHALL HAVE PUSH-ON JOINTS MEETING THE REQUIREMENTS OF AWWA STANDARD C111. THE WALL THICKNESS OF THE PIPE SHALL BE CLASS 52. PIPE SHALL BE MANUFACTURED BY U.S. PIPE, AMERICAN PIPE, OR MCWANE DUCTILE. THE EXTERIOR SHALL BE COATED WITH A LAYER OF ARC-SPRAYED ZINC PER ISO 8179. THE MASS OF THE ZINC APPLIED SHALL BE 200 G/M2 OF PIPE SURFACE AREA. A FINISHING LAYER TOPCOAT SHALL BE APPLIED TO THE ZINC. THE MEAN DRY FILM THICKNESS OF THE FINISHING LAYER SHALL NOT BE LESS THAN 3 MILS WITH A LOCAL MINIMUM NOT LESS THAN 2 MILS. THE ZINC COATING SYSTEM SHALL CONFORM TO ISO 8179-1 “DUCTILE IRON PIPES - EXTERNAL ZINC-BASED COATING - PART 1: METALLIC ZINC WITH FINISHING LAYER. SECOND EDITION 2004-06-01.” VERTICAL SCALE: 1" = 5' 5 2.5 0 5 10 15 HORIZONTAL SCALE: 1" = 50' 50 25 0 50 100 150 STANDARD TRENCHINGENOT TO SCALE 700 705 710 715 720 725 730 735 700 705 710 715 720 725 730 735 10+00 11+00 12+00 13+00 14+00 15+0012+30.98=4' MANHOLEINV. OUT=717.75 (24")INV. IN=717.85 (6")INV. IN=718.31 (6")INV. IN=717.85 (18")TOP=721.268 10+00=FLAIRED END SECTIONINV. IN=716.02 (24")TOP=718.77EX.13+56.48=18" ADS MHINV. OUT=718.48 (18")INV. IN=718.98 (12")INV. IN=718.48 (8")TOP=721.268A 13+72.52=18" AREA DRAININV. OUT=719.06 (12")INV. IN=719.16 (12")INV. IN=719.12 (6")TOP=724.388B TOP=724.349 14+03.53=18" AREA DRAININV. OUT=720.26 (12"INV. IN=720.36 (EX. 12")INV. IN=720.61 (6")EX. TOP=726.76EX. EX. 10 14+28.50= 15" ADS MHINV. OUT=720.53 (12")INV. IN=720.55 (6")INV. IN=720.55 (12")1.5' MIN. CLEAR OVER WATER LINE PR. GRADE 12+55.98=15"X15"X6" TEECONNNECTION TO TD1INV.=717.8412+80.98=15"X15"X6" TEECONNNECTION TO TD2INV.=717.97EX. GRADE EX. GRADE PR. GRADE 11+54.45=8" W/L XINGINV.=714.93CLASS I RIP RAP 182.37' - 24" CORRUGATED HDPE PIPE@ 0.50% EX. 24.97' - 12" HDPE @ 0.68% 25.00' - 18" CORRUGATED HDPE PIPE @ 0.50% 31.01' - 12" HDPE @ 3.55% 16.04' - 12" HDPE @ 0.50% 10-YR HGL LINE 10-YR HGL LINE 10+48.61=MH-1INV. OUT=716.74 (24")INV. IN=716.84 (24")TOP=720.087 13+05.98=15"X15"X6" TEECONNNECTION TO TD3INV.=718.0913+30.98=15"X15"X6" TEECONNNECTION TO TD4INV.=718.22EX. 48.61' - 24" RCP CL IV @ 1.48% BOTTOM OF TRENCH INV. = 720.09' VERTICAL OUTLET ADAPTER TO STRUCTURE TD6 (6" X 6" X 4" T-Y) SEE DETAILS 'E' ADN 'F' ON SHEET 13 13.5'12'12'12'12'12'3'12'12'12'12' 1'1'1'1' FLOW FLOW FLOW FLOW FLOW FLOWFLOWFLOWFLOWFLOWFLOW BOTTOM OF TRENCH INV. = 720.09' VERTICAL OUTLET ADAPTER TO STRUCTURE TD5 (6" X 6" X 4" T-Y) SEE DETAILS 'E' ADN 'F' ON SHEET 13 BOTTOM OF TRENCH INV. = 720.09' VERTICAL OUTLET ADAPTER TO STRUCTURE TD4 (6" X 6" X 4" T-Y) SEE DETAILS 'E' ADN 'F' ON SHEET 13 BOTTOM OF TRENCH INV. = 720.09' VERTICAL OUTLET ADAPTER TO STRUCTURE TD3 (6" X 6" X 4" T-Y) SEE DETAILS 'E' ADN 'F' ON SHEET 13 BOTTOM OF TRENCH INV. = 720.09' VERTICAL OUTLET ADAPTER TO STRUCTURE TD2 (6" X 6" X 4" T-Y) SEE DETAILS 'E' ADN 'F' ON SHEET 13 BOTTOM OF TRENCH INV. = 720.09' VERTICAL OUTLET ADAPTER TO STRUCTURE TD1 (6" X 6" X 4" T-Y) SEE DETAILS 'E' ADN 'F' ON SHEET 13 700 705 710 715 720 725 700 705 710 715 720 725 10+00 11+00TOP=716.20HDW EX. EX. 10 EX. GRADE PR. GRADE 10+00.00=EXISTING CULVERTINV. OUT=713.15 (24")10+47.09=CONCRETE HEADWALLINV. IN=713.20 (24")EX. 46.00' - 24" CMP @ 0.11% EX. RIP RAP CONCRETE HEADWALL CONTROLLED LOW STRENGTH MATERIAL STORM SEWER PROFILE AND COMPUTATIONS12 C-CU-202.DWG C-CU-202 1" = 50' 1" = 5' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-202.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-202.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 VERTICAL SCALE: 1" = 5' 5 2.5 0 5 10 15 HORIZONTAL SCALE: 1" = 50' 50 25 0 50 100 150 STORM DRAIN PROFILE STORM DRAIN COMPUTATIONS STORM DRAIN HGL COMPUTATIONS CITY OF WINCHESTER MANHOLE LIDANOT TO SCALE VDOT MANHOLEBNOT TO SCALE STANDARD DI-3 LID AND FRAME TRENCH DRAIN PROFILE NOT TO SCALE STORM CULVERT PROFILE 12.53'6" SANITARY TEE (T-Y) WITH 4" BRANCH; SEE DETAIL 'E' THIS SHEET. ROOF LEADER CONNECTION; SEE UTILITY PLAN CONNECTION TO ADS STRUCTURE OR 15"X15"X6" TEE; SEE UTILITY PLAN ACO FLOW DRAIN ASSEMBLY; SEE DETAIL 'A' AND 'B', THIS SHEET ACO FLOW DRAIN GRATE ASSEMBLY; SEE DETAIL 'C' THIS SHEET ACO FLOW DRAIN VERTICAL OUTLET ADAPTER; SEE DETAIL 'A' THIS SHEET VARIABLE FLOW 6" PVC6" PVC 4" PVC UTILITY DETAILS13 C-CU-501.DWG C-CU-501 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-501.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-501.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 ACO DRAIN TO ROOF LEADER CONNECTIONFNOT TO SCALE ACO TRENCH DRAINANOT TO SCALE ACO TRENCH DRAINBNOT TO SCALE ACO TRENCH DRAIN GRATECNOT TO SCALE ADS 18" NYLOPLAST DRAIN BASINDNOT TO SCALE E NOT TO SCALE 6" X 6" X 4" TEE (T-Y) CONNECTION UTILITY DETAILS14 C-CU-501.DWG C-CU-501 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-501.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-501.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 STANDARD ENDWALL FOR PIPE CULVERTS DETAILANOT TO SCALE SWM EMBANKMENT DETAILBNOT TO SCALE NOTE: EXECUTE ALL POND EMBANKMENT RESTORATION IN ACCORDANCE WITH THE RECOMENDATIONS PROVIDED IN THE OCTOBER 16TH, 2023 GEOTECHNICAL ENGINEERING REPORT BY ECS MID-ATLANTIC SIGNED AND SEALED BY SENIOR ENGINEERING GEOLOGIST, NICHOLAS C. BASS. 1": 1' 2"R4" 6"13"6"2' 6"13"4" 2' 6" 1": 1' 2"R CG-6 CG-6R CG-6R CG-6CG-6 TRANSITION CURB TRANSITION DETAIL (NOT TO SCALE) DETAIL DETAIL NOT TO SCALE NOT TO SCALE DT-CG6R 7" 7" 10'10' 6" 3" IM-19.0A INTERMEDIATE COURSE SM-9.5A SURFACE COURSE TACK COAT 1.5" SUBGRADE COMPACTED TO 95% DENSITY COMPACTED AGGREGATE BASE, TYPE 1 SIZE #21A, 95% DENSITY 8" 6" 4" A3 PORTLAND CEMENT CONCRETE (5000 PSI COMPRESSIVE STRENGTH AT 28 DAYS) #4 BARS @ 12" O.C. (BOTH WAYS) COMPACTED AGGREGATE BASE, TYPE 1 SIZE #21A, 95% DENSITY SUBGRADE COMPACTED TO 95% DENSITY 6" 6" 3" A3 PORTLAND CEMENT CONCRETE (5000 PSI COMPRESSIVE STRENGTH AT 28 DAYS) 4" X 4" - W2.9 X W2.9 WWM REINFORCED STEEL IS NOT CARRIED THROUGH JOINTS SUBGRADE COMPACTED TO 95% DENSITY COMPACTED AGGREGATE BASE, TYPE 1 SIZE #21A, 95% DENSITY CHAIRS AT 2' SPACING O.C. INTERMEDIATE COURSE 1.5" 1V 4H HEAVY DUTY ASPHALT SECTIONEXISTING APSHALT PAVEMENT SECTION 6" 3" 1.5" COMPACTED AGGREGATE BASE, TYPE 1 SIZE #21A, 95% DENSITY SURFACE COURSE MATCH DEPTH OF EXISTING BASE COURSE SURFACE COURSE 1.5" SM-9.5A CONTINUOUS OVER EXISTING PAVEMENT TACK COAT FACE OF EXPOSED INTERMEDIATE COURSE 12"12" EX. EX. TACK COAT FACE OF EXPOSED INTERMEDIATE COURSE INTERMEDIATE COURSE 1V 4H HEAVY DUTY ASPHALT SECTION LIGHT DUTY ASPHALT SECTION 6" 3" 1.5" COMPACTED AGGREGATE BASE, TYPE 1 SIZE #21A, 95% DENSITY SURFACE COURSE SURFACE COURSE 1.5" SM-9.5A CONTINUOUS OVER EXISTING PAVEMENT 1.5" 1.5" TRANSITION SECTION 6" HEAVY DUTY ASPHALT SECTION 6" 4.5" BITUMINOUS COURSE(S) 4H (MIN.) TACK COAT 1V 5' MIN HEAVY DUTY CONCRETE SECTION 8" TACK COAT X X X X X X X X X X 3" MAX 6" 4H (MIN.) 1V PER PLAN COMPACTED AGGREGATE BASE, TYPE 1 SIZE #21A, 95% DENSITY X X 6" 1.5" IM-19.0A INTERMEDIATE COURSE SM-9.5A SURFACE COURSE TACK COAT 1.5" SUBGRADE COMPACTED TO 95% DENSITY COMPACTED AGGREGATE BASE, TYPE 1 SIZE #21A, 95% DENSITY SITE DETAILS15 C-CS-501.DWG C-CS-501 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-501.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-501.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 CG-6 AND CG-6R CURB B HEAVY DUTY ASPHALT PAVEMENT SECTIONC CONCRETE DUMPSTER PADD E HEAVY DUTY CONCRETE PAVEMENT SECTION NOT TO SCALE NOT TO SCALENOT TO SCALE NOT TO SCALE F TRANSITION HEAVY DUTY ASPHALT TO LIGHT DUTY ASPHALT NOT TO SCALE G NOT TO SCALE H NOT TO SCALE TRANSITION HEAVY DUTY ASPHALT TO EXISTING ASPHALT PAVEMENT TRANSITION HEAVY DUTY ASPHALT TO HEAVY DUTY CONCRETE PAVEMENT I CG-2 CURB NOT TO SCALE LIGHT DUTY ASPHALT PAVEMENT SECTIONJNOT TO SCALE DTW JOINT SEALER INITIAL SAWCUT (1/8") CRACK JOINT BOTTOM BACKER OR INSERT CONTRACTION JOINT W = WIDTH OF SEALANT RESERVOIR (1/2" (MIN), 5/8" (MAX)) D = DEPTH OF SEALANT (1.0 TO 1.5W) T = DEPTH OF INITIAL SAWCUT OR INSERT TYPE JOINT MATERIAL PAVEMENT SURFACE FORMER (CONTRACTION JOINT) SHALL BE 1/4 SLAB THICKNESS NOTE 1: BACKER MATERIAL SHALL MEET THE REQUIREMENTS OF ACI 504R PARAGRAPHS 2.8, 3.4.6.2, 3.4.6.3 AND TABLE AS APPLICABLE. NOTE 2: TOP OF SEALANT WILL BE 1/8" TO 1/4" BELOW TOP OF JOINT SEALANT DETAILS N.T.S. CONSTRUCTION JOINT MATERIALTD BUTTED JOINT BACKER JOINT SEALER PAVEMENT SURFACEW (BACKER MATERIAL) EXPANSION JOINT JOINT SEALER BACKER MATERIALD3/4"PAVEMENT SURFACE JOINT FILLER 3/4" MIN JOINT SEALANT DETAILS (SEPARATING TAPE) CONTRACTION JOINT W TDINITIAL SAWCUT (1/8") OR INSERT CRACK PAVEMENT SURFACE JOINT SEALER JOINT BOTTOM N.T.S. (SEPARATION TAPE) JOINT SEALANT DETAILS BUTTED JOINT JOINT SEALANT DETAILS (SEPARATING TAPE) SEPARATING TAPE JOINT SEALER PAVEMENT SURFACE CONSTRUCTION JOINT W DPAVEMENT SURFACE SEPARATING TAPE JOINT SEALER 3/4" MIN JOINT FILLER EXPANSION JOINT D3/4" NOTE 2: TOP OF SEALANT WILL BE 1/8" TO 1/4" BELOW TOP OF PARAGRAPHS 2.8, 3.4.6.2, 3.4.6.3 AND TABLE AS APPLICABLE. NOTE 1: SEPARATING TAPE SHALL MEET THE REQUIREMENTS OF ACI 504R FORMER (CONTRACTION JOINT) SHALL BE 1/4 SLAB THICKNESS T = DEPTH OF INITIAL SAWCUT OR INSERT TYPE JOINT D = DEPTH OF SEALANT (1.0 TO 1.5W) PAVEMENT SURFACE FOR EXTERIOR PAVEMENTS. W = WIDTH OF SEALANT RESERVOIR (1/2" (MIN), 5/8" (MAX)) SEPARATING TAPE JOINT BOTTOM JOINT BOTTOM PAVEMENT SURFACE FOR EXTERIOR PAVEMENTS. NOTE: EITHER THE SEPARATION TAPE OR BACKER MATERIAL DETAILS SHALL BE USED. THIS DETAIL PER USACE DETAILS RECEIVED 6/5/2020 TE REQUIRED AT ALL FREE EDGE TEJ REQUIRED ADJACENT TO STRUCTURES AND ABUTTING EXISTING CONCRETE SEE JOINT SEAL DETAILS 5' MIN 9" 7" TE REQUIRED AT ALL FREE EDGE TEJ REQUIRED ADJACENT TO STRUCTURES AND ABUTTING EXISTING CONCRETE SEE JOINT SEAL DETAILS 5' MIN 9" 7" THICKENED-EDGE EXPANSION JOINT N.T.S. 7" 5' MIN (TEJ) N.T.S. CONTRACTION/CONSTRUCTION JOINT (CJ) SEE JOINT SEALANT DETAILS 3.5" ± 1/2" 7" 3/4" 3/4" 3" MAX 3" MAX 3" MAX THICKENED-EDGE (TE) JOINT & THICKENED-EDGE EXPANSION JOINT (TEJ) N.T.S. 3/4" OR 1" DIAMETER, 16" LONG DOWEL, SPACED 12" CENTER TO CENTER. ONE END PAINTED AND OILED. NOTES: CONTRACTION JT. (BY SAWING OR INSERT) IS SHOWN. CONSTRUCTION JT. IS SMOOTH JT. (BUTT JOINT) CREATED BY FORMING. BOTH JOINT TYPES SHALL BE DOWELED. NON-EXTRUDING JOINT FILLER STRIP 2.75" 4" x 4" - W4 xW4 WWM 2.75" 4" x 4" - W4 xW4 WWM NON-EXTRUDING JOINT FILLER STRIP 2.75" 4" x 4" - W4 xW4 WWM x x x x x x x x x SITE DETAILS16 C-CS-501.DWG C-CS-501 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-501.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-501.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 A JOINT SEALANT DETAILS NOT TO SCALE B JOINT DETAILS NOT TO SCALE BUILDING FACE TRENCH DRAIN RIM = 720.91'GRADE AT LOADING DOCK = 720.95' F.F.E.= 724.95' EDGE OF DRIVE AISLE 722.10' 2.0'58.0'5.0' 2.0% 722.23'SITE DETAILS17 C-CS-501.DWG C-CS-501 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-501.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-501.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 CG-12 DETECTABLE WARNING SURFACE (PARALLEL INSTALLATION)D STANDARD CONCRETE SIDEWALKANOT TO SCALE NOT TO SCALE LOADING DOCK CROSS SECTION A-ABNOT TO SCALE NOTES: CAP BOARDALUMINUM POST CAP 3. ALL LUMBER SHALL BE PRESSURE TREATED SOUTHERN 1. PROVIDE SHOP DRAWINGS FOR REVIEW BY THE OWNERS REPRESENTATIVE PRIOR TO FABRICATION OR INSTALLATION. 1.25 " MAX 1X4 OR 1X6 SLATS, 2 FINISH NAILS AT EACH BEAM TOP VIEW, CAP BOARD REMOVED BEAM SLAT POST, SEE TABLEPOST 3,000 PSI CONCRETE 2. INSTALLATION AND ALIGNMENT OF THE FENCE TO BE IN ACCORDANCE WITH THE CONTRACT DRAWINGS.6'0"114"MIN.14"3" MAX. 8'-0" YELLOW PINE (0.04 CCA). 2X4 BEAMS, SEE TABLE, GALVANIZED SUPPORT BRACKET REQUIRED 14"INCLUDE GATES, CONNECTION DETAILS, AND ANY OTHER NON-STANDARD DETAILS. NOTES: G. OTHER SPECIAL SIGNS AS APPROVED BY THE OFFICE OF THE FIRE MARSHAL. BETWEEN SIGNS IS 70 FEET. SPACED AS ON APPROVED PLANS. IN LONG STRETCHES THE MAXIMUM DISTANCE INSTALLATION FROM THE OFFICE OF THE FIRE MARSHAL. SIGNS SHOULD BE UNLESS WRITTEN PERMISSION FOR ALTERNATIVES IS OBTAINED PRIOR TO SOLID HEAD 1 1/2" WIDE AND 2" DEEP. AREAS WHERE NO CURB EXISTS. PAINT SHALL BE TRAFFIC YELLOW GRADE. A 6" YELLOW STRIPE SHALL BE PAINTED ON PAVEMENT EDGE IN FIRE LANE F. POSTS FOR SIGNS, WHEN REQUIRED, SHALL BE METAL AND SECURELY MOUNTED. E. SIGNS ARE TO BE MOUNTED 7' FROM THE GROUND TO THE BOTTOM OF THE SIGN UNLESS OTHERWISE DIRECTED BY THE OFFICE OF THE FIRE MARSHAL. APPROVED SIGNS SHALL BE AS FOLLOWS: A. METAL CONSTRUCTION, 12" x 18". AROUND ENTIRE OUTER EDGE OF SIGN. B. RED LETTERS ON REFLECTIVE WHITE BACKGROUND WITH 3/8" RED TRIM STRIP C. LETTERING TO BE AS SHOWN ABOVE. "OR" - 1", "FIRE LANE" - 2 1/2", ARROWS 1" X 6" SOLID SHAFT WITH A D. LETTERING SIZE TO BE AS FOLLOWS: "NO PARKING" OR "STANDING" - 2", ALL CURBS OR PAVED SPACES DESIGNATED AS FIRE LANES SHALL BE INDICATED BY YELLOW PAINT AS APPROVED BY THE FIRE PREVENTION DIVISION. DT-FIRES FIRE LANE NO TYPE A PARKING TYPE D LANE FIRE PARKING LANE FIRE PARKING NO TYPE C NO 36"7'3"-4" TAPER 1-1/4" 3-1/8"1.516NUT AND WASHER SECTION SIGN MOUNTS BETWEEN FRONT WASHER AND SIGN POST REQUIRED HARDWARE: 2-5/16" X 2-1/2" HEX-HEAD BOLTS 2-5/16" HEX NUTS 4-5/16" FLAT WASHERS (ZINC PLATED) 5/16" HEX NUT 5/16" FLAT WASHER 5/16" FLAT WASHER GROUND LEVEL FRONT WASHER BOLT AND WASHER 5/16" X 2-1/2" HEX-HEAD BOLT STANDARD 2#/10' GALVANIZED STEEL U-CHANNEL SIGN POST COLOR AS EXISTING 3/8" HOLES SPACED 1" ON CENTER 2#/10' GALVANIZED STEEL U-CHANNEL SIGN POST C PARKING STALLL R=5"18"5"TYP1'-0"9° 4'-6"9'-0"EDGE OF PVMT26"4" R=1 8 " R=13"6" 4"10" 12"6"6"6" 6" 1" PAINT BLUE PAINT WHITE 20" 4" WIDE BLUE STRIPING4'-0" TOPAINT WHITE SAMPLE TO ENGINEER FOR APPROVAL CONTRACTOR TO SUBMIT PRODUCT (3'-0" MIN. LENGTH) #4 REBAR (TYP.) A1 6'-0" A1 PRE-CAST WHEEL STOP PRIOR TO INSTALLATION. SECTION A1-A1 CONC. MIN. 6" 9" 3000 PSI SITE DETAILS18 C-CS-501.DWG C-CS-501 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-501.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-501.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 WOODEN SCREENING FENCEASCALE: 3/8" = 1'-0" NO PARKING SIGNSBNOT TO SCALE SIGN POSTCNOT TO SCALE ADA PARKING STRIPINGDNOT TO SCALE CONCRETE WHEEL STOPENOT TO SCALE EROSION AND SEDIMENT CONTROL NOTES19 C-GC-001.DWG C-GC-001 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-001.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-001.DWG, 2/2/2024 3:43 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 E&S CONTROL MINIMUM STANDARDS: A VESCP MUST BE CONSISTENT WITH THE FOLLOWING CRITERIA, TECHNIQUES AND METHODS: 1.PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN 14 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN ONE YEAR. 2.DURING CONSTRUCTION OF THE PROJECT, SOIL STOCK PILES AND BORROW AREAS SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL STOCKPILES ON SITE AS WELL AS BORROW AREAS AND SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE. 3.A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON DENUDED AREAS NOT OTHERWISE PERMANENTLY STABILIZED. PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT IS UNIFORM, MATURE ENOUGH TO SURVIVE AND WILL INHIBIT EROSION. 4.SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND-DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. 5.STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONS IMMEDIATELY AFTER INSTALLATION. 6.SEDIMENT TRAPS AND SEDIMENT BASINS SHALL BE DESIGNED AND CONSTRUCTED BASED UPON THE TOTAL DRAINAGE AREA TO BE SERVED BY THE TRAP OR BASIN. A.THE MINIMUM STORAGE CAPACITY OF A SEDIMENT TRAP SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA AND THE TRAP SHALL ONLY CONTROL DRAINAGE AREAS LESS THAN THREE ACRES. B.SURFACE RUNOFF FROM DISTURBED AREAS THAT IS COMPRISED OF FLOW FROM DRAINAGE AREAS GREATER THAN OR EQUAL TO THREE ACRES SHALL BE CONTROLLED BY A SEDIMENT BASIN. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT BASIN SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA. THE OUTFALL SYSTEM SHALL, AT A MINIMUM, MAINTAIN THE STRUCTURAL INTEGRITY OF THE BASIN DURING A 25-YEAR STORM OF 24-HOUR DURATION. RUNOFF COEFFICIENTS USED IN RUNOFF CALCULATIONS SHALL CORRESPOND TO A BARE EARTH CONDITION OR THOSE CONDITIONS EXPECTED TO EXIST WHILE THE SEDIMENT BASIN IS UTILIZED. 7.CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION. SLOPES THAT ARE FOUND TO BE ERODING EXCESSIVELY WITHIN ONE YEAR OF PERMANENT STABILIZATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE STABILIZING MEASURES UNTIL THE PROBLEM IS CORRECTED. 8.CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME OR SLOPE DRAIN STRUCTURE. 9.WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED. 10.ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT-LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. 11.BEFORE NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS OR PIPES ARE MADE OPERATIONAL, ADEQUATE OUTLET PROTECTION AND ANY REQUIRED TEMPORARY OR PERMANENT CHANNEL LINING SHALL BE INSTALLED IN BOTH THE CONVEYANCE CHANNEL AND RECEIVING CHANNEL. 12.WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS SHALL BE TAKEN TO MINIMIZE ENCROACHMENT, CONTROL SEDIMENT TRANSPORT AND STABILIZE THE WORK AREA TO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NONERODIBLE MATERIAL SHALL BE USED FOR THE CONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USED FOR THESE STRUCTURES IF ARMORED BY NONERODIBLE COVER MATERIALS. 13.WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES MORE THAN TWICE IN ANY SIX-MONTH PERIOD, A TEMPORARY VEHICULAR STREAM CROSSING CONSTRUCTED OF NONERODIBLE MATERIAL SHALL BE PROVIDED. 14.ALL APPLICABLE FEDERAL, STATE AND LOCAL REQUIREMENTS PERTAINING TO WORKING IN OR CROSSING LIVE WATERCOURSES SHALL BE MET. 15.THE BED AND BANKS OF A WATERCOURSE SHALL BE STABILIZED IMMEDIATELY AFTER WORK IN THE WATERCOURSE IS COMPLETED. 16.UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: A.NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. B.EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. C.EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF-SITE PROPERTY. D.MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. E.RESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THIS CHAPTER. F. APPLICABLE SAFETY REQUIREMENTS SHALL BE COMPLIED WITH. 17.WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SHALL APPLY TO INDIVIDUAL DEVELOPMENT LOTS AS WELL AS TO LARGER LAND-DISTURBING ACTIVITIES. 18.ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE VESCP AUTHORITY. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. 19.PROPERTIES AND WATERWAYS DOWNSTREAM FROM DEVELOPMENT SITES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION, EROSION AND DAMAGE DUE TO INCREASES IN VOLUME, VELOCITY AND PEAK FLOW RATE OF STORMWATER RUNOFF FOR THE STATED FREQUENCY STORM OF 24-HOUR DURATION IN ACCORDANCE WITH THE FOLLOWING STANDARDS AND CRITERIA. STREAM RESTORATION AND RELOCATION PROJECTS THAT INCORPORATE NATURAL CHANNEL DESIGN CONCEPTS ARE NOT MAN-MADE CHANNELS AND SHALL BE EXEMPT FROM ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS: A.CONCENTRATED STORMWATER RUNOFF LEAVING A DEVELOPMENT SITE SHALL BE DISCHARGED DIRECTLY INTO AN ADEQUATE NATURAL OR MAN-MADE RECEIVING CHANNEL, PIPE OR STORM SEWER SYSTEM. FOR THOSE SITES WHERE RUNOFF IS DISCHARGED INTO A PIPE OR PIPE SYSTEM, DOWNSTREAM STABILITY ANALYSES AT THE OUTFALL OF THE PIPE OR PIPE SYSTEM SHALL BE PERFORMED. B.ADEQUACY OF ALL CHANNELS AND PIPES SHALL BE VERIFIED IN THE FOLLOWING MANNER: (1)THE APPLICANT SHALL DEMONSTRATE THAT THE TOTAL DRAINAGE AREA TO THE POINT OF ANALYSIS WITHIN THE CHANNEL IS 100 TIMES GREATER THAN THE CONTRIBUTING DRAINAGE AREA OF THE PROJECT IN QUESTION; OR (2)(A) NATURAL CHANNELS SHALL BE ANALYZED BY THE USE OF A TWO-YEAR STORM TO VERIFY THAT STORMWATER WILL NOT OVERTOP CHANNEL BANKS NOR CAUSE EROSION OF CHANNEL BED OR BANKS; (B)ALL PREVIOUSLY CONSTRUCTED MAN-MADE CHANNELS SHALL BE ANALYZED BY THE USE OF A 10-YEAR STORM TO VERIFY THAT STORMWATER WILL NOT OVERTOP ITS BANKS AND BY THE USE OF A TWO-YEAR STORM TO DEMONSTRATE THAT STORMWATER WILL NOT CAUSE EROSION OF CHANNEL BED OR BANKS; AND (C)PIPES AND STORM SEWER SYSTEMS SHALL BE ANALYZED BY THE USE OF A 10-YEAR STORM TO VERIFY THAT STORMWATER WILL BE CONTAINED WITHIN THE PIPE OR SYSTEM. C.IF EXISTING NATURAL RECEIVING CHANNELS OR PREVIOUSLY CONSTRUCTED MAN-MADE CHANNELS OR PIPES ARE NOT ADEQUATE, THE APPLICANT SHALL: E&S CONTROL MINIMUM STANDARDS (CONT.): (1)IMPROVE THE CHANNELS TO A CONDITION WHERE A 10-YEAR STORM WILL NOT OVERTOP THE BANKS AND A TWO-YEAR STORM WILL NOT CAUSE EROSION TO THE CHANNEL, THE BED, OR THE BANKS; (2)IMPROVE THE PIPE OR PIPE SYSTEM TO A CONDITION WHERE THE 10-YEAR STORM IS CONTAINED WITHIN THE APPURTENANCES; (3)DEVELOP A SITE DESIGN THAT WILL NOT CAUSE THE PRE-DEVELOPMENT PEAK RUNOFF RATE FROM A TWO-YEAR STORM TO INCREASE WHEN RUNOFF OUTFALLS INTO A NATURAL CHANNEL OR WILL NOT CAUSE THE PRE-DEVELOPMENT PEAK RUNOFF RATE FROM A 10-YEAR STORM TO INCREASE WHEN RUNOFF OUTFALLS INTO A MAN-MADE CHANNEL; OR (4)PROVIDE A COMBINATION OF CHANNEL IMPROVEMENT, STORMWATER DETENTION OR OTHER MEASURES WHICH IS SATISFACTORY TO THE VESCP AUTHORITY TO PREVENT DOWNSTREAM EROSION. D.THE APPLICANT SHALL PROVIDE EVIDENCE OF PERMISSION TO MAKE THE IMPROVEMENTS. E.ALL HYDROLOGIC ANALYSES SHALL BE BASED ON THE EXISTING WATERSHED CHARACTERISTICS AND THE ULTIMATE DEVELOPMENT CONDITION OF THE SUBJECT PROJECT. F. IF THE APPLICANT CHOOSES AN OPTION THAT INCLUDES STORMWATER DETENTION, HE SHALL OBTAIN APPROVAL FROM THE VESCP OF A PLAN FOR MAINTENANCE OF THE DETENTION FACILITIES. THE PLAN SHALL SET FORTH THE MAINTENANCE REQUIREMENTS OF THE FACILITY AND THE PERSON RESPONSIBLE FOR PERFORMING THE MAINTENANCE. G.OUTFALL FROM A DETENTION FACILITY SHALL BE DISCHARGED TO A RECEIVING CHANNEL, AND ENERGY DISSIPATORS SHALL BE PLACED AT THE OUTFALL OF ALL DETENTION FACILITIES AS NECESSARY TO PROVIDE A STABILIZED TRANSITION FROM THE FACILITY TO THE RECEIVING CHANNEL. H.ALL ON-SITE CHANNELS MUST BE VERIFIED TO BE ADEQUATE. I. INCREASED VOLUMES OF SHEET FLOWS THAT MAY CAUSE EROSION OR SEDIMENTATION ON ADJACENT PROPERTY SHALL BE DIVERTED TO A STABLE OUTLET, ADEQUATE CHANNEL, PIPE OR PIPE SYSTEM, OR TO A DETENTION FACILITY. J. IN APPLYING THESE STORMWATER MANAGEMENT CRITERIA, INDIVIDUAL LOTS OR PARCELS IN A RESIDENTIAL, COMMERCIAL OR INDUSTRIAL DEVELOPMENT SHALL NOT BE CONSIDERED TO BE SEPARATE DEVELOPMENT PROJECTS. INSTEAD, THE DEVELOPMENT, AS A WHOLE, SHALL BE CONSIDERED TO BE A SINGLE DEVELOPMENT PROJECT. HYDROLOGIC PARAMETERS THAT REFLECT THE ULTIMATE DEVELOPMENT CONDITION SHALL BE USED IN ALL ENGINEERING CALCULATIONS. K.ALL MEASURES USED TO PROTECT PROPERTIES AND WATERWAYS SHALL BE EMPLOYED IN A MANNER WHICH MINIMIZES IMPACTS ON THE PHYSICAL, CHEMICAL AND BIOLOGICAL INTEGRITY OF RIVERS, STREAMS AND OTHER WATERS OF THE STATE. L. ANY PLAN APPROVED PRIOR TO JULY 1, 2014, THAT PROVIDES FOR STORMWATER MANAGEMENT THAT ADDRESSES ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS SHALL SATISFY THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS IF THE PRACTICES ARE DESIGNED TO (I) DETAIN THE WATER QUALITY VOLUME AND TO RELEASE IT OVER 48 HOURS; (II) DETAIN AND RELEASE OVER A 24-HOUR PERIOD THE EXPECTED RAINFALL RESULTING FROM THE ONE YEAR, 24-HOUR STORM; AND (III) REDUCE THE ALLOWABLE PEAK FLOW RATE RESULTING FROM THE 1.5, 2, AND 10-YEAR, 24-HOUR STORMS TO A LEVEL THAT IS LESS THAN OR EQUAL TO THE PEAK FLOW RATE FROM THE SITE ASSUMING IT WAS IN A GOOD FORESTED CONDITION, ACHIEVED THROUGH MULTIPLICATION OF THE FORESTED PEAK FLOW RATE BY A REDUCTION FACTOR THAT IS EQUAL TO THE RUNOFF VOLUME FROM THE SITE WHEN IT WAS IN A GOOD FORESTED CONDITION DIVIDED BY THE RUNOFF VOLUME FROM THE SITE IN ITS PROPOSED CONDITION, AND SHALL BE EXEMPT FROM ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS AS DEFINED IN ANY REGULATIONS PROMULGATED PURSUANT TO § 62.1-44.15:54 OR 62.1-44.15:65 OF THE ACT. M.FOR PLANS APPROVED ON AND AFTER JULY 1, 2014, THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS OF § 62.1-44.15:52 A OF THE ACT AND THIS SUBSECTION SHALL BE SATISFIED BY COMPLIANCE WITH WATER QUANTITY REQUIREMENTS IN THE STORMWATER MANAGEMENT ACT (§ 62.1-44.15:24 ET SEQ. OF THE CODE OF VIRGINIA) AND ATTENDANT REGULATIONS, UNLESS SUCH LAND-DISTURBING ACTIVITIES (I) ARE IN ACCORDANCE WITH PROVISIONS FOR TIME LIMITS ON APPLICABILITY OF APPROVED DESIGN CRITERIA IN 9VAC25-870-47 OR GRANDFATHERING IN 9VAC25-870-48 OF THE VIRGINIA STORMWATER MANAGEMENT PROGRAM (VSMP) REGULATION, IN WHICH CASE THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS OF § 62.1-44.15:52 A OF THE ACT SHALL APPLY, OR (II) ARE EXEMPT PURSUANT TO § 62.1-44.15:34 C 7 OF THE ACT. N.COMPLIANCE WITH THE WATER QUANTITY MINIMUM STANDARDS SET OUT IN 9VAC25-870-66 OF THE VIRGINIA STORMWATER MANAGEMENT PROGRAM (VSMP) REGULATION SHALL BE DEEMED TO SATISFY THE REQUIREMENTS OF THIS SUBDIVISION 19. EROSION AND SEDIMENT CONTROL NARRATIVE THE SITE DISTURBANCE IS GREATER THAN 10,000 SF. THEREFORE, PER SECTION 143-110, VIRGINIA EROSION AND SEDIMENT CONTROL PROGRAM (VESCP) LAND DISTURBANCE OR VESCP LAND-DISTURBING ACTIVITY, THE SITE DISTURBANCE IS CLASSIFIED AS AN EROSION AND SEDIMENT CONTROL LAND DISTURBING ACTIVITY AND IS SUBJECT TO THE REQUIREMENTS OF SECTION 143-160 OF THE FREDERICK COUNTY CODE. PROJECT DESCRIPTION: THE PURPOSE OF THIS PROJECT IS THE CONSTRUCTION OF A LOADING DOCK EXPANSION ALONG THE SOUTH WESTERN PORTION OF THE EXISTING BUILDING, INCLUDING A DRIVE-IN RAMP, THE RELOCATION OF STORM SEWER INFRASTRUCTURE AND FIRE HYDRANTS, AND MAINTENANCE OF AN EXISTING DRY POND. THE TOTAL DISTURBED AREA TO INCLUDE NEW IMPROVEMENTS IS APPROXIMATELY 1.11 ACRES OR 48,385 SF. THE TOTAL PROJECT LIMITS OF CLEARING AND GRADING INCLUDING MAINTENANCE OF THE EXISTING DRY POND IS APPROXIMATELY 2.17 ACRES OR 94,362 SF. EXISTING SITE CONDITIONS: THE EXISTING SITE CONSISTS OF WAREHOUSING SPACE AND A VALLEY HEALTH EPIC TRAINING CENTER. SEE APPROVED SITE PLAN SP# 26-13. MULTIPLE EXISTING LOADING DOCKS ARE LOCATED ALONG THE SOUTH WESTERN PORTION OF THE BUILDING. A MAJORITY OF THE SITE IS VERY FLAT WITH SLOPES RANGING FROM LESS THAN 1% TO 5% AND DRAINS TO THE SOUTH EAST TO EXISTING CULVERTS ADJACENT TO TYSON DRIVE. THE WESTERN CORNER OF THE SITE NEAR WHERE IMPROVEMENTS ARE PROPOSED CONTAINS SLOPES RANGING FROM 5% TO 27%. ADJACENT AREAS: THE SITE IS SURROUNDED BY SIMILAR WAREHOUSING AND DISTRIBUTION FACILITIES ALL ZONED M1. THE ONLY ROAD ADJACENT TO THE SITE IS TYSON DRIVE ALONG THE SOUTH EASTERN PROPERTY LINE. OFF-SITE AREAS: THERE ARE NO PLANNED OFF-SITE AREAS FOR THIS PROJECT. ALL WORK SHALL BE COMPLETED INSIDE OF THE PROPERTY. SOILS: SOIL DATA HAS BEEN OBTAINED FROM WEB SOIL SURVEY. REFER TO GEOTECH REPORT FOR ADDITIONAL INFORMATION THE SOILS ON THE SITE ARE: -(5C) CARBO SILT LOAM, 7 TO 15 PERCENT SLOPES, WELL DRAINED, K=0.43, VERY LOW TO MODERATELY LOW CAPACITY 0.00 TO 0.06 IN/HR., HYDROLOGIC SOIL GROUP 'D' -(32B) OAKLET SILT LOAM, 2 TO 7 PERCENT SLOPES, WELL DRAINED, K=0.37, MODERATELY LOW TO MODERATELY HIGH CAPACITY 0.06 TO 0.20 IN/HR., HYDROLOGIC SOIL GROUP 'C' -(14B) FREDERICK-POPLIMENTO LAOMS, 2 TO 7 PERCENT SLOPES, WELL DRAINED, K=0.28, MODERATELY HIGH TO HIGH CAPACITY 0.57 TO 1.98 IN/HR,. HYDROLOGIC SOIL GROUP 'B' -(39B) SWIMLEY SILT LOAM, 2 TO 7 PERCENT SLOPES, WELL DRAINED, K=0.43, MODERATELY HIGH TO HIGH CAPACITY 0.57 TO 1.98 IN/HR,. HYDROLOGIC SOIL GROUP 'B' SEE MAP BELOW FOR SOIL BOUNDARIES: GENERAL EROSION AND SEDIMENT CONTROL NOTES: 1.DEVICES SHOWN ON PLANS ARE TO BE CONSIDERED THE MINIMUM EROSION AND SEDIMENT CONTROLS. PROVIDE ADDITIONAL DEVICES AS NEEDED IN ORDER TO CONTROL EROSION AND SEDIMENTATION. 2.EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSTALLED AND MAINTAINED ACCORDING TO THE STANDARDS AND SPECIFICATIONS IN THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. 3.ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED. 4.PROVIDE CLEANING AND REMOVAL OF SEDIMENT AND MUD FROM PUBLIC OR PRIVATE ROADWAYS AS NECESSARY. 5.TOPSOIL THAT HAS BEEN STOCKPILED IS TO BE SURROUNDED BY SILT FENCE OR OTHER MEASURES AND SHALL BE PROTECTED BY MULCH AND/OR TEMPORARY VEGETATION AT ALL TIMES IMMEDIATELY AFTER GRADING. ADDITIONAL MEASURES TO INCLUDE BE NOT LIMITED TO; BERMS, DIKES, SILT FENCE SANDBAGS OR STRAW BALE BARRIERS. 6.ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO OR AS THE FIRST STEP IN CLEARING. 7.THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES AS NECESSARY TO PREVENT EROSION AND SEDIMENTATION. 8.TRAPPED SEDIMENT IS TO BE REMOVED AS REQUIRED TO MAINTAIN EFFICIENCY AND TO BE DISPOSED OF BY SPREADING ON-SITE. 9.TRENCHING ACTIVITIES SHALL BE DONE IN ACCORDANCE WITH THE VIRGINIA EROSION AND SEDIMENT CONTROL MINIMUM STANDARDS SECTION 16 AND IN ACCORDANCE WITH FREDERICK WATER TRENCHING AND BEDDING DETAIL ON SHEET CU-202. 10.REFER TO GEOTECH REPORT FOR INSTRUCTIONS ON STORMWATER POND EMBANKMENT RECONSTRUCTION, EMBANKMENT FILL REQUIREMENTS, AND POND LINER. MAINTENANCE: THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES DAILY AND AFTER EACH RUNOFF-PRODUCING RAINFALL EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. THE FOLLOWING ITEMS SHALL BE CHECKED IN PARTICULAR: 1.CONSTRUCTION ENTRANCE (3.02): SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOW OF MUD ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE OR THE WASHING AND REWORKING OF EXISTING STONE AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY STRUCTURES USED TO TRAP SEDIMENT. ALL MATERIALS SPILLED, DROPPED, WASHED, OR TRACKED FROM VEHICLES ONTO ROADWAYS OR INTO STORM DRAINS MUST BE REMOVED IMMEDIATELY. 2.SILT FENCE (3.05): a)SILT FENCE SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REPAIRS SHALL BE MADE IMMEDIATELY. b)SHOULD THE FABRIC ON A SILT FENCE DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE LIFE AND THE BARRIER STILL BE NECESSARY, THE FABRIC SHALL BE REPLACED PROMPTLY. c)SEDIMENT DEPOSITS SHOULD BE REMOVED AFTER EACH STORM EVENT. THEY MUST BE REMOVED WHEN DEPOSITS REACH APPROXIMATELY ONE-HALF THE HEIGHT OF THE BARRIER. d)ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE IS NO LONGER REQUIRED SHALL BE DRESSED TO CONFORM WITH THE EXISTING GRADE, PREPARED AND SEEDED. 3.STORM DRAIN INLET PROTECTION (3.07/3.08): THE STRUCTURE SHALL BE INSPECTED AFTER EACH RAIN AND REPAIRS MADE AS NEEDED. SEDIMENT SHALL BE REMOVED AND THE TRAP RESTORED TO ITS ORIGINAL DIMENSIONS. REMOVED SEDIMENT SHALL BE DEPOSITED IN A SUITABLE AREA AND IN SUCH A MANNER THAT IT WILL NOT ERODE. STRUCTURES SHALL BE REMOVED AND THE AREA STABILIZED WHEN THE REMAINING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. 4.TREE PRESERVATION AND PROTECTION (3.38): IF THE SOIL HAS BEEN COMPACTED OVER THE ROOT ZONE OF ANY TREE, THE GROUND SHALL BE AERATED BY PUNCHING HOLES IN SOIL UNTIL LOOSENED. ANY DAMAGE TO THE CROWN, TRUNK, OR ROOT SYSTEM OF ANY TREE SHALL BE RETAINED IMMEDIATELY. SEQUENCE OF CONSTRUCTION: PHASE 1 1.FLAG LIMITS OF CONSTRUCTION ACTIVITIES. 2.SCHEDULE AND HOLD ON SITE PRE CONSTRUCTION MEETING. 3.INSTALL CONSTRUCTION ENTRANCE AND WASH RACK AND PERIMETER CONTROLS. 4.INSTALL INLET PROTECTION ON ALL EXISTING STORM INLETS AND STORMWATER CONVEYANCE STRUCTURES. 5.BEGIN DEMOLITION OF EXISTING SITE FEATURES, ROUGH SITE GRADING, AND CLEARING OF TREES AND BUSHES AFTER EROSION AND SEDIMENT CONTROL MEASURES HAVE BEEN APPROVED BY THE COUNTY SITE INSPECTOR. 6.INSTALL ALL UNDERGROUND UTILITIES. 7.DO NOT PROCEED TO PHASE 2 UNTIL AUTHORIZED BY SITE INSPECTOR. PHASE 2 1.MAINTAIN ALL PERIMETER CONTROLS AND OTHER EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY. 2.RELOCATE EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY. 3.INSTALL INLET PROTECTION ON NEW STORM STRUCTURES. 4.CLEAR AND GRUB REMAINDER OF SITE. 5.FINE GRADE SITE FOR CONSTRUCTION AND PAVING OF PARKING LOT. 6.CONSTRUCT BUILDING ADDITION, LOADING DOCK RETAINING WALLS, AND ASSOCIATED HARDSCAPES INCLUDING BUT NOT LIMITED TO CURB AND GUTTER AND SIDEWALKS. 7.REMOVE VEGETATION FROM STORMWATER POND AREA AND EMBANKMENT. INSTALL OUTFALL HEADWALL. RESTORE POND AND EMBANKMENT GRADE. STABILIZE DRY POND. 8.PERMANENTLY STABILIZE LANDSCAPED AREAS AND LAWN AREAS. 9.INSTALL ALL PROPOSED LANDSCAPE FEATURES. 10.COMPLETE FINAL SITE STABILIZATION. 11.WITH PERMISSION OF THE COUNTY SITE INSPECTOR, REMOVE TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES. GEOLOGY: NO RECENT GEOTECHNICAL REPORT HAS BEEN PERFORMED FOR THIS SITE. CRITICAL AREAS: THERE ARE NO CRITICAL EROSION AREAS ON SITE. EROSION AND SEDIMENT CONTROL MEASURES: 1.CONSTRUCTION ENTRANCE (3.02) TO MINIMIZE THE AMOUNT OF SEDIMENT CARRIED FROM THE SITE ONTO PUBLIC AND PRIVATE ROADS. ONE (1) CONSTRUCTION ENTRANCE IS REQUIRED FOR ACCESS TO THE SITE. 2.SAFETY FENCE (3.01) TO PREVENT ACCESS TO AN EROSION CONTROL MEASURE. 3.SILT FENCE (3.05) TO FILTER RUNOFF FROM DISTURBED AREAS BEFORE IT LEAVES THE PROPERTY. SILT FENCE SHOULD BE REPLACED ON A REGULAR BASIS ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 4.STORM DRAIN INLET PROTECTION (3.07) TO MINIMIZE SILTATION OF EXISTING STORM SEWER INLETS WITHIN THE SITE. 5.CULVERT INLET PROTECTION (3.08) TO FILTER SEDIMENT AND PREVENT IT FROM ENTERING IN OR ACCUMULATING IN A STORM SEWER CULVERT. 6.PIPE OULET PROTECTION (3.18) TO PROTECT THE OUTLET STRUCTURE AND MINIMIZE DOWNSTREAM EROSION POTENTIAL BY REDUCING THE VELOCITY OF STORMWATER FLOWS. 7.TREE PROTECTION (3.38) TO PROTECT DESIRABLE TREES FROM LAND DISTURBING AND CONSTRUCTION ACTIVITIES. PERMANENT STABILIZATION: ALL AREAS TO BE LEFT UNCOVERED BY BUILDINGS OR PAVEMENT SHALL BE IMMEDIATELY STABILIZED WITH PERMANENT SEEDING FOLLOWING GRADING OPERATIONS. SEEDING SCHEDULE SHALL BE IN ACCORDANCE WITH THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (VESCH). ANY VARIANCE FROM THESE MEASURES SHALL BE APPROVED BY THE LOCAL EROSION CONTROL AUTHORITY. VEGETATIVE PRACTICES: 1.TEMPORARY SEEDING (3.31) - ALL DENUDED AREAS THAT WILL NOT BE BROUGHT TO FINAL GRADE FOR A PERIOD OF MORE THAN 14 DAYS SHALL BE TEMPORARILY SEEDED. TEMPORARY SEEDING SCHEDULE TO BE IN ACCORDANCE WITH THE VESCH. 2.PERMANENT SEEDING (3.32) - ALL DENUDED AREAS SHALL BE RESEEDED, MULCHED, AND FERTILIZED AS NECESSARY OBTAIN PERENNIAL VEGETIVE COVER AFTER FINAL GRADING OPERATIONS. VEGETATIVE STABILIZATION SHALL BE UNIFORM, MATURE ENOUGH TO SURVIVE AND ADEQUATE TO INHIBIT EROSION. SOILS MAP (SCALE 1" = 500') PROJECT SITE 32B 32B 14B 5C 14B 39B VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3WxWxLP L P L P LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX. SCUPPER EX. SCUPPER EX. CURB & GUTTER EX. CURB & GUTTER EX CONCRETE EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. RIP-RAP EX. WALK W/STEPS EX. SCUPPER EX. CONC. DUMPSTER PAD EX. HVAC EX. HVAC EX. SCREEN WALL RD RD RD RD RD RD RD RD RD RD RD EX. 6 EX. 7 EX. 8 EX. 9 EX. 10 INV.=716.74' INV.=718.12'12" HDPE12" HDPE12" HDPE 12" HDPE6"PVC 12" HDPE18" RCP EX. CONC. WALKSIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE EX. 6" WATER LINE EX. 8" WATER LINE NO RECORD OF EXISTING EASEMENT SEE UTILITY PLAN AND PLAT OF EASEMENT FOR ESTABLISHMENT OF NEW EASEMENT 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50' EX. 20' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. 10' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 725730 735 740 735740740740735740 735 730725 725730735735 725720716720725725721 72 4 720 720 722 723 724 724725 726 724 722 719717LCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LC G LCGLCG LCG LCGLCG LCG LCG LC G LCG LCG LCG LCGLCG LCG LCG LCG LCG LCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCG WASH RACK TO STR. A = AC C = INLET 0.41 0.70 OP IP CIP CE TP TP SF TO STR. A = AC C = EX. 9 1.24 0.50 TO STR. A = AC C = EX. 9 0.63 0.90 TO STR. A = AC C = EX. 2 11.82 0.71 XXSAF SAF SAF SAF GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 EROSION AND SEDIMENT CONTROL PLAN PHASE 120 C-GC-101.DWG C-GC-101 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-101.DWG, 2/2/2024 3:44 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-101.DWG, 2/2/2024 3:44 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 MATCH LINE SEE SHEET 21 LG-ES1 EROSION/SEDIMENT CONTROL LEGEND NO. KEY SYMBOL DESCRIPTION CE SF3.05 3.02 SILT FENCE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE X X X STORM DRAIN INLET PROTECTION3.07 IP OP3.18 OUTLET PROTECTION PS3.32 PS PERMANENT SEEDING TREE PROTECTION3.38 TP DRAINAGE DIVIDES CRITICAL SLOPE - CRITICAL SLOPE TO BE SEEDED, MULCHED AND TACKED WITHIN 14 DAYS AFTER START OF GRADING, OR SODDED AND PEGGED WITHIN 14 DAYS AFTER START SAF3.01 CONSTRUCTION SAFETY FENCE CULVERT INLET PROTECTION3.08 CIP E&S NOTES: 1.SEE SHEET 24 FOR EROSION AND SEDIMENT CONTROL DETAILS. 2.SEE SHEET 19 FOR EROSION AND SEDIMENT CONTROL NOTES. 3.CONTRACTOR TO ENSURE POSITIVE DRAINAGE AWAY FROM THE PROPERTY. 4.TREE PROTECTION TO BE INSTALLED ON ALL TREES TO REMAIN INSIDE OF THE LIMITS OF WORK. ADJUST CONSTRUCTION SAFETY FENCE AS NECESSARY TO PROVIDE TREE PROTECTION. 5.LIMITS OF CLEARING AND GRADING DENOTES CONTRACTOR LIMITS OF WORK INCLUDING STAGING, STORING, AND LAYDOWN MATERIALS. NO LAND DISTURBANCE IS PERMITTED OUTSIDE OF THE LIMITS DELINEATED ON THIS SHEET. 6.EXECUTE WORK WITHIN VDOT RIGHT-OF-WAY WITH THREE DAY DRY WEATHER FORECAST. IMMEDIATELY STABILIZE EMBANKMENT WITH EC-3 MATTING FOLLOWING REMOVAL OF VEGETATION PER THE GEOTECH REPORT. LCG LIMITS OF CLEARING AND GRADINGLCG IPF INV.=713.22' INV.=713.15' INV.=712.11' INV.=711.96' INV.=712.26' INV.=714.98' INV.=713.45' INV.=712.78' INV.=712.88'24" CMP(3)-48" CMP INV.=714.14' EX. EDGE OF PAVEMENT EX. EDGE OF PAVEMENT EX. CONC.EX. CURB & GUTTEREX. SCUPPER EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. ASPHALT EX. ASPHALT EX. CONCRETE EX. RIP-RAP EX. CURB & GUTTER EX. EDGE OF PAVEMENT TOP=717.34 EX. 1 EX. 2 EX. 3 STONEWALL INDUSTRIAL PARK 75' FRONT YARD SETBACK Wx Wx Wx EX. FCSA SANITARY SEWER EASEMENT INSTR. #060014178 EX. 20' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. RIP-RAP724720720720 716716718719720715715719718718 720 718717715715718719717 714 715 716 718 714 714 715 715 716 717 715 714 715 713 714 LCG LCG LCG LCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCG LCG LCG LCG CIP OP SAF SAF SAF SAF SAF SF WASH RACK CE XXX X X XSF SAFSA CO EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. RIP-RAP EX. EDGE OF PAVEMENT INV.=716.74' INV.=718.12' 18" RCP SIGN INV.=716.02'N47°34'13"W 990.00'25' SIDE YARD SETBACK725 725730735 730 727725 725720729 7167177177207 2 5 720 719719718717LCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCG LCG LCG CIP TO STR. A = AC C = EX. 2 11.82 0.71 SAF SAF SAF VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 DRY POND EROSION AND SEDIMENT CONTROL PLAN PHASE 121 C-GC-101.DWG C-GC-101 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-101.DWG, 2/2/2024 3:44 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-101.DWG, 2/2/2024 3:44 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 MATCH LINE SEE SHEET 20 MATCH LINE SEE THIS SHEET MATCH LINE SEE THIS SHEET LG-ES1 EROSION/SEDIMENT CONTROL LEGEND NO. KEY SYMBOL DESCRIPTION CE SF3.05 3.02 SILT FENCE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE X X X STORM DRAIN INLET PROTECTION3.07 IP OP3.18 OUTLET PROTECTION PS3.32 PS PERMANENT SEEDING TREE PROTECTION3.38 TP DRAINAGE DIVIDES CRITICAL SLOPE - CRITICAL SLOPE TO BE SEEDED, MULCHED AND TACKED WITHIN 14 DAYS AFTER START OF GRADING, OR SODDED AND PEGGED WITHIN 14 DAYS AFTER START SAF3.01 CONSTRUCTION SAFETY FENCE CULVERT INLET PROTECTION3.08 CIP E&S NOTES: 1.SEE SHEET 24 FOR EROSION AND SEDIMENT CONTROL DETAILS. 2.SEE SHEET 19 FOR EROSION AND SEDIMENT CONTROL NOTES. 3.CONTRACTOR TO ENSURE POSITIVE DRAINAGE AWAY FROM THE PROPERTY. 4.TREE PROTECTION TO BE INSTALLED ON ALL TREES TO REMAIN INSIDE OF THE LIMITS OF WORK. ADJUST CONSTRUCTION SAFETY FENCE AS NECESSARY TO PROVIDE TREE PROTECTION. 5.LIMITS OF CLEARING AND GRADING DENOTES CONTRACTOR LIMITS OF WORK INCLUDING STAGING, STORING, AND LAYDOWN MATERIALS. NO LAND DISTURBANCE IS PERMITTED OUTSIDE OF THE LIMITS DELINEATED ON THIS SHEET. 6.EXECUTE WORK WITHIN VDOT RIGHT-OF-WAY WITH THREE DAY DRY WEATHER FORECAST. IMMEDIATELY STABILIZE EMBANKMENT WITH EC-3 MATTING FOLLOWING REMOVAL OF VEGETATION PER THE GEOTECH REPORT. LCG LIMITS OF CLEARING AND GRADINGLCG VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3725730 735 740 735740740740735740 735 730725 725730735735 725720720719LP L P L P LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX CONCRETE EX. ASPHALT EX. SCREEN WALL RD RD RD RD EX. 6 EX. 10 12" HDPE6"PVC 12" HDPE18" RCP SIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50' EX. 20' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. 10' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 720725730 721721 722722722 723723724726727728729731 732 733 723724720 721 722 721 722 725 FFE = 724.95'WWW8 7 9 RD7 RD6 RD5 RD4 RD3 TD6 TD5 TD4 TD3 TD2 RD1 TD1 RD2 T4 8A 8B T1 T2 T3 LCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LC G LCGLCG LCG LCGLCG LCG LCG LC G LCG LCG LCG LCGLCG LCG LCG LCG LCG LCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCG TO STR. A = AC C = RD3 0.07 0.90 CE TO STR. A = AC C = RD2 0.07 0.90 TO STR. A = AC C = RD4 0.07 0.90 TO STR. A = AC C = RD5 0.07 0.90 TO STR. A = AC C = RD6 0.07 0.90 TO STR. A = AC C = RD7 0.05 0.90 TO STR. A = AC C = 9 0.07 0.90 TO STR. A = AC C = 8 0.09 0.90 TO STR. A = AC C = EX. 10 0.36 0.30 TO STR. A = AC C = RD1 0.07 0.90 TO STR. A = AC C = EX. 10 0.09 0.90 TO STR. A = AC C = 9 0.20 0.31 TO STR. A = AC C = TD6 0.54 0.60 TO STR. A = AC C = TD5 0.09 0.88 TO STR. A = AC C = TD4 0.06 0.90 TO STR. A = AC C = TD3 0.06 0.90 TO STR. A = AC C = TD2 0.06 0.90 TO STR. A = AC C = TD1 0.06 0.90 TO STR. A = AC C = EX. 2 11.89 0.71 SF XXSAF OP CIP TP TP WASH RACK IP IPPS PS PS PS PS PS PS SAF SAF SAFSAF OP OP OP RIP RAP DIMENSIONS WIDTH AT SCUPPER = 4' LENGTH = 10' TOE WIDTH = 12' SIZE D50 = 6" RIP RAP DIMENSIONS WIDTH AT SCUPPER = 4' LENGTH = 10' TOE WIDTH = 12' SIZE D50 = 6" SEE DETAIL 'H' ON SHEET 24 FOR RIP RAP DIMENSIONS GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 EROSION AND SEDIMENT CONTROL PLAN PHASE 222 C-GC-102.DWG C-GC-102 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-102.DWG, 2/2/2024 3:44 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-102.DWG, 2/2/2024 3:44 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 MATCH LINE SEE SHEET 21 LG-ES1 EROSION/SEDIMENT CONTROL LEGEND NO. KEY SYMBOL DESCRIPTION CE SF3.05 3.02 SILT FENCE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE X X X STORM DRAIN INLET PROTECTION3.07 IP OP3.18 OUTLET PROTECTION PS3.32 PS PERMANENT SEEDING TREE PROTECTION3.38 TP DRAINAGE DIVIDES CRITICAL SLOPE - CRITICAL SLOPE TO BE SEEDED, MULCHED AND TACKED WITHIN 14 DAYS AFTER START OF GRADING, OR SODDED AND PEGGED WITHIN 14 DAYS AFTER START SAF3.01 CONSTRUCTION SAFETY FENCE CULVERT INLET PROTECTION3.08 CIP E&S NOTES: 1.SEE SHEET 24 FOR EROSION AND SEDIMENT CONTROL DETAILS. 2.SEE SHEET 19 FOR EROSION AND SEDIMENT CONTROL NOTES. 3.CONTRACTOR TO ENSURE POSITIVE DRAINAGE AWAY FROM THE PROPERTY. 4.TREE PROTECTION TO BE INSTALLED ON ALL TREES TO REMAIN INSIDE OF THE LIMITS OF WORK. ADJUST CONSTRUCTION SAFETY FENCE AS NECESSARY TO PROVIDE TREE PROTECTION. 5.LIMITS OF CLEARING AND GRADING DENOTES CONTRACTOR LIMITS OF WORK INCLUDING STAGING, STORING, AND LAYDOWN MATERIALS. NO LAND DISTURBANCE IS PERMITTED OUTSIDE OF THE LIMITS DELINEATED ON THIS SHEET. 6.EXECUTE THE WORK FOR THE STORMWATER POND EMBANKMENT RECONSTRUCTION AND POND LINER IN ACCORDANCE WITH THE RECOMMENDATIONS PROVIDED IN THE OCTOBER 16TH, 2023 GEOTECHNICAL ENGINEERING REPORT BY ECS MID-ATLANTIC SIGNED AND SEALED BY SENIOR ENGINEERING GEOLOGIST NICHOLAS C. BASS. 7.EXECUTE WORK WITHIN VDOT RIGHT-OF-WAY WITH THREE DAY DRY WEATHER FORECAST. IMMEDIATELY STABILIZE EMBANKMENT WITH EC-3 MATTING FOLLOWING REMOVAL OF VEGETATION PER THE GEOTECH REPORT. LCG LIMITS OF CLEARING AND GRADINGLCG 724720720720719720719 720 718719717 714 715 716 718 714 714 715 715 716 717 715 714 715 713 IPF INV.=713.15' INV.=712.11' INV.=711.96' INV.=712.26' INV.=714.98' INV.=713.45' INV.=712.78' INV.=712.88'24" CMP(3)-48" CMP INV.=714.14' EX. EDGE OF PAVEMENT EX. EDGE OF PAVEMENT EX. CONC.EX. CURB & GUTTEREX. ASPHALT EX. ASPHALT EX. CONCRETE EX. RIP-RAP EX. CURB & GUTTER EX. EDGE OF PAVEMENT TOP=717.34 EX. 1 EX. 2 EX. 3 STONEWALL INDUSTRIAL PARK 75' FRONT YARD SETBACK Wx Wx Wx EX. FCSA SANITARY SEWER EASEMENT INSTR. #060014178 EX. 20' DRAINAGE & UTILITY EASEMENT DB. 649 PG. 471 EX. RIP-RAP LCG LCG LCG LCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCG LCG LCG LCG OP SAF SAF SAF SAF SAF SF WASH RACK CEXXX XXXXX X X XSF SF OP OP OP OP RIP RAP DIMENSIONS WIDTH AT SCUPPER = 4' LENGTH = 10' TOE WIDTH = 12' SIZE D50 = 6" RIP RAP DIMENSIONS WIDTH AT SCUPPER = 4' LENGTH = 10' TOE WIDTH = 12' SIZE D50 = 6" RIP RAP DIMENSIONS WIDTH AT SCUPPER = 4' LENGTH = 10' TOE WIDTH = 12' SIZE D50 = 6" RIP RAP DIMENSIONS WIDTH AT SCUPPER = 4' LENGTH = 10' TOE WIDTH = 12' SIZE D50 = 6" RIP RAP DIMENSIONS WIDTH AT SCUPPER = 4' LENGTH = 10' TOE WIDTH = 12' SIZE D50 = 6" INV. = 713.20' 725 725730735 730 727725 725720729 7207 2 5 719719SA CO EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. EDGE OF PAVEMENT 18" RCP SIGN INV.=716.02'N47°34'13"W 990.00'25' SIDE YARD SETBACK7 LCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCG LCG LCG CIP SAF SAF SAF SAF OP OP OP OP OP RIP RAP DIMENSIONS WIDTH AT SCUPPER = 4' LENGTH = 10' TOE WIDTH = 12' SIZE D50 = 6" RIP RAP DIMENSIONS WIDTH AT SCUPPER = 4' LENGTH = 10' TOE WIDTH = 12' SIZE D50 = 6" RIP RAP DIMENSIONS WIDTH AT SCUPPER = 4' LENGTH = 10' TOE WIDTH = 12' SIZE D50 = 6" RIP RAP DIMENSIONS WIDTH AT SCUPPER = 4' LENGTH = 10' TOE WIDTH = 12' SIZE D50 = 6" SEE DETAIL 'H' ON SHEET 24 FOR RIP RAP DIMENSIONS VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 DRY POND EROSION AND SEDIMENT CONTROL PLAN PHASE 223 C-GC-102.DWG C-GC-102 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-102.DWG, 2/2/2024 3:44 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-102.DWG, 2/2/2024 3:44 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 LG-ES1 EROSION/SEDIMENT CONTROL LEGEND NO. KEY SYMBOL DESCRIPTION CE SF3.05 3.02 SILT FENCE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE X X X STORM DRAIN INLET PROTECTION3.07 IP OP3.18 OUTLET PROTECTION PS3.32 PS PERMANENT SEEDING TREE PROTECTION3.38 TP DRAINAGE DIVIDES CRITICAL SLOPE - CRITICAL SLOPE TO BE SEEDED, MULCHED AND TACKED WITHIN 14 DAYS AFTER START OF GRADING, OR SODDED AND PEGGED WITHIN 14 DAYS AFTER START SAF3.01 CONSTRUCTION SAFETY FENCE CULVERT INLET PROTECTION3.08 CIP G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-102.DWG, 2/2/2024 3:44 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 MATCH LINE SEE SHEET 22 MATCH LINE SEE THIS SHEET MATCH LINE SEE THIS SHEET E&S NOTES: 1.SEE SHEET 24 FOR EROSION AND SEDIMENT CONTROL DETAILS. 2.SEE SHEET 19 FOR EROSION AND SEDIMENT CONTROL NOTES. 3.CONTRACTOR TO ENSURE POSITIVE DRAINAGE AWAY FROM THE PROPERTY. 4.TREE PROTECTION TO BE INSTALLED ON ALL TREES TO REMAIN INSIDE OF THE LIMITS OF WORK. ADJUST CONSTRUCTION SAFETY FENCE AS NECESSARY TO PROVIDE TREE PROTECTION. 5.LIMITS OF CLEARING AND GRADING DENOTES CONTRACTOR LIMITS OF WORK INCLUDING STAGING, STORING, AND LAYDOWN MATERIALS. NO LAND DISTURBANCE IS PERMITTED OUTSIDE OF THE LIMITS DELINEATED ON THIS SHEET. 6.EXECUTE THE WORK FOR THE STORMWATER POND EMBANKMENT RECONSTRUCTION AND POND LINER IN ACCORDANCE WITH THE RECOMMENDATIONS PROVIDED IN THE OCTOBER 16TH, 2023 GEOTECHNICAL ENGINEERING REPORT BY ECS MID-ATLANTIC SIGNED AND SEALED BY SENIOR ENGINEERING GEOLOGIST NICHOLAS C. BASS. 7.EXECUTE WORK WITHIN VDOT RIGHT-OF-WAY WITH THREE DAY DRY WEATHER FORECAST. IMMEDIATELY STABILIZE EMBANKMENT WITH EC-3 MATTING FOLLOWING REMOVAL OF VEGETATION PER THE GEOTECH REPORT. LCG LIMITS OF CLEARING AND GRADINGLCG 4.5' 10'11.5' NOTES: 1.ROCK OUTLET PROTECTION DESIGNED PER PLATE 3.18-3 OF THE VESCH. 2.RIPRAP SIZE D50 = 6". CONSTRUCTION ROCK OUTLET PROTECTION AROUND EXISTING SCUPPER EROSION AND SEDIMENT CONTROL DETAILS24 C-GC-501.DWG C-GC-501 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-501.DWG, 2/2/2024 3:44 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 CONSTRUCTION SAFETY FENCEANOT TO SCALE CULVERT INLET PROTECTIONENOT TO SCALE Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-501.DWG, 2/2/2024 3:44 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 CONSTRUCTION ENTRANCEBNOT TO SCALE SILT FENCECNOT TO SCALE INLET PROTECTIONDNOT TO SCALE TREE PROTECTIONGNOT TO SCALE PIPE OUTLET PROTECTIONFNOT TO SCALE CAF CE SF IP TPOPCIP ROCK OUTLET PROTECTIONHSCALE: 1" = 10' VIRGI N I A S T A T E G R I D N O R T H - N A D 8 3 SIGN 725730 740 735 730725 720725725721 72 4 720 720 722 723 724 724725 726 724 722 719LODLODLODLOD LODLODLODLODLODLODLODLOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODIMPERVIOUS COVER FOREST/OPEN SPACE (NONE SHOWN) LEGEND LIMITS OF DISTURBANCE (FOR STORMWATER COMPUTATION PURPOSES ONLY) MANAGED TURF LOD SYMBOL DESCRIPTION HYDROLOGIC SOIL GROUP (PER FREDERICK COUNTY GIS) (SEE KEYED MAP) B D LIMITS OF WORK (EXEMPT FROM STORMWATER COMPUTATION) LOW VIRGI N I A S T A T E G R I D N O R T H - N A D 8 3 SIGN 725730 740 735 730725 720725725721 72 4 720 720 722 723 724 724725 726 724 722 719720725730 721721 722722722 723723724726727728729 731 732 733 723724720 721 722 721 722 725 LODLODLODLOD LODLODLODLODLODLODLODLOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLOD723 LODLODVIRGI N I A S T A T E G R I D N O R T H - N A D 8 3 723 LODLODVIRGI N I A S T A T E G R I D N O R T H - N A D 8 3 BC TYSON DRIVE - ROUTE 863 80' RIGHT-OF-WAY DB. 733 PG. 517 MBMB SIGN SIGN SIGN LODLOD LODLOWLOWLOWLOWLOWVIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 PRE & POST-DEVELOPMENT LAND COVER MAPS25 C-CJ-110.DWG C-CJ-110 AS NOTED N/A GORDON C. LETCHWORTH K. RYAN K. RYAN POST-DEVELOPMENT LAND COVER & DRAINAGE AREA MAPB PRE & POST-DEVELOPMENT LAND COVER MAPS PRE-DEVELOPMENT LAND COVER & DRAINAGE AREA MAPA GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CJ-110.DWG, 2/2/2024 10:42 AM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 KEYED MAPC GRAPHICAL SCALE: 1" = 150' 150 75 0 150 300 450 SCALE: 1" = 150' INSET MAP 1 INSET MAP 2 INSET MAP 1 INSET MAP 2 INSET MAP 1 INSET MAP 2 SCALE: 1" = 20' SCALE: 1" = 20' SCALE: 1" = 20' SCALE: 1" = 20' VIRGI N I A S T A T E G R I D N O R T H - N A D 8 3 1 TYSON DRIVE - ROUTE 863 80' RIGHT-OF-WAY DB. 733 PG. 517 MB MBMB MB MBMB RD RD RD RD RD RD RD RD RD RD RD EX.1 EX. 2 EX.3 EX. 4 EX.5 EX.6 EX.7 EX.8 EX.9 EX.10 ACACAC AC SIGN SIGN SIGN LODLODLOD LODLODLOWLOWLOWLOWLOWLOWLOWLOW725725750 DRAINAGE DIVIDE DRAINAGE AREA LIMITS OF DISTURBANCE (FOR STORMWATER COMPUTATION PURPOSES ONLY) LEGEND IMPERVIOUS COVER FOREST/OPEN SPACE (NONE SHOWN) MANAGED TURF # SYMBOL DESCRIPTION LOD LIMITS OF WORK (EXEMPT FROM STORMWATER COMPUTATION) LOW VIRGI N I A S T A T E G R I D N O R T H - N A D 8 3 1 8 7 9 RD7 RD6 RD5 RD4 RD3 TD6 TD5 TD4 TD3 TD2 RD1 TD1 RD2 T4 8A 8B T1 T2 T3 TYSON DRIVE - ROUTE 863 80' RIGHT-OF-WAY DB. 733 PG. 517 MB MBMB MB MBMB RD RD RD RD EX.1 EX.2 EX.3 EX.4 EX.5 EX.6 EX.10 ACACAC AC SIGN SIGN SIGN 720725730 721721 722722722 723723724726727728729731732733 723724720 721 722 721 722 725LODLODLODLOD LODLOWLOWLOWLOWLOWLOWLOWLOW725725750 PRE & POST-DEVELOPMENT DRIANAGE AREA MAPS26 C-CJ-120.DWG C-CJ-120 1" = 100' N/A GORDON C. LETCHWORTH K. RYAN K. RYAN POST-DEVELOPMENT DRAINAGE AREA MAPB PRE & POST-DEVELOPMENT DRAINAGE AREA MAPS PRE-DEVELOPMENT DRAINAGE AREA MAPA GRAPHICAL SCALE: 1" = 100' 100 50 0 100 200 300 Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CJ-120.DWG, 2/2/2024 10:54 AM, cletchworth VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 NUTRIENT CREDIT LETTER OF AVAILABILITYB WATER QUALITY NARRATIVE THIS APPLICATION INCLUDES THE FOLLOWING TYPES OF LAND DISTURBANCE: ·THE SITE DISTURBANCE IS APPROXIMATELY 1.1 ACRES AND IS DEFINED ON THE PLANS AS “LOD” (LIMITS OF DISTURBANCE). THE LOD CONSISTS OF THE CONSTRUCTION OF A LOADING DOCK AND ASSOCIATED SITE IMPROVEMENTS. ·THE LIMITS OF WORK IS APPROXIMATELY 1.0 ACRES AND IS DEFINED ON THE PLANS AS “LOW” (LIMITS OF WORK). THE LOW INCLUDES THE WORK TO RESTORE THE ORIGINAL LINE AND GRADE AND DESIGN FUNCTION OF THE EXISTING DRY POND ON THE SITE. PER SECTION 62.1-44.15:34.C.7 OF THE STORMWATER MANAGEMENT ACT, THESE DRY POND RESTORATION OPERATIONS ARE EXEMPT FROM SWM. WATER QUALITY REQUIREMENTS THE SITE LOD IS SUBJECT TO THE REQUIREMENTS OF SECTION 9VAC25-870-63.2.C OF THE VSMP REGULATIONS, AS ADOPTED BY SECTION 143-165.C OF THE FREDERICK COUNTY STORMWATER/EROSION AND SEDIMENT CONTROL ORDINANCE, FOR DEVELOPMENT ON PRIOR DEVELOPED LANDS THAT RESULT IN A NET INCREASE IN IMPERVIOUS COVER FROM THE PRE-DEVELOPMENT CONDITION. THE LIMITS OF WORK HAS BEEN EXCLUDED FROM THE STORMWATER MANAGEMENT WATER QUALITY ANALYSIS SINCE IT IS AN EXEMPT ACTIVITY. WATER QUALITY COMPLIANCE WATER QUALITY COMPLIANCE IS ACHIEVED THROUGH THE USE OF OFFSITE COMPLIANCE OPTIONS. PER SECTION 9VAC25-870-69 OF THE VSMP REGULATION, AS ADOPTED BY SECTION 143-165.B.8 OF THE FREDERICK COUNTY STORMWATER/EROSION AND SEDIMENT CONTROL ORDINANCE, STORMWATER OFFSITE COMPLIANCE OPTIONS MAY BE UTILIZED TO MEET THE REQUIRED PHOSPHORUS NUTRIENT REDUCTIONS. AS SET FORTH IN SECTION 9VAC25-870-69.A.3, THE NUTRIENT CREDITS WILL BE PURCHASED FROM THE NONPOINT NUTRIENT OFFSET PROGRAM. PER SECTION SECTION 9VAC25-870-69.B.1;, THE SITE QUALIFIES WITH A SITE DISTURBANCE LESS THAN FIVE (5) ACRES. THE SITE IS LOCATED WITHIN THE REDBUD RUN-OPEQUON WATERSHED (0207-0004-0903) AND POTOMAC/SHENANDOAH WATERSHED (0207-0004). THE NUTRIENT CREDIT ELIGIBILITY HAS BEEN EVALUATED PER THE REQUIREMENTS OF SECTION 9VAC25-900-91. THE FIRST ASSESSED RECEIVING WATER IS REDBUD RUN AND IT HAS NOT BEEN ASSESSED FOR AN APPLICABLE IMPAIRMENT. THEREFORE, THE PURCHASE OF NUTRIENT CREDITS IS NOT SUBJECT TO THE HIERARCHY ESTABLISHED IN SECTION 9VAC25-900. CREDITS ARE AVAILABLE FROM THE HUC8 WATERSHED, AND A NUTRIENT CREDIT AVAILABILITY LETTER HAS BEEN PROVIDED ON THIS SHEET FROM A BANK IN THAT WATERSHED. PER DEQ GUIDANCE MEMO 21-2007, NUTRIENT BANK SERVICES ARE BASED ON THE DATE OF THE NUTRIENT CREDIT AVAILABILITY LETTER ON THE SUBMITTED STORMWATER MANAGEMENT PLANS FOR REVIEW. SHOULD THE NUTRIENT CREDIT AMOUNT INCREASE ABOVE THE AVAILABILITY LETTER, OR NUTRIENT CREDITS BE SECURED FROM AN ALTERNATE BANK, A NEW NUTRIENT CREDIT AVAILABILITY LETTER AND EVALUATION FOR CONFORMANCE WITH THE REQUIREMENTS OF SECTION 9VAC25-900-91 SHALL BE CONDUCTED. NUTRIENT CREDITS SHALL BE SECURED PRIOR TO OBTAINING COVERAGE UNDER THE DEQ CONSTRUCTION GENERAL PERMIT, ISSUANCE OF A LOCAL SITE DISTURBANCE PERMIT, AND ANY SITE DISTURBANCE. WATER QUANTITY NARRATIVE IN THE PRE-DEVELOPMENT AND POST-DEVELOPMENT CONDITION, THE SITE DISTURBANCE DRAINS TO AN EXISTING DRY POND ON THE SITE. THE DRY POND WAS DESIGNED WITH THE AMENDED SITE PLAN TITLED “PROPOSED BUILDING ADDITION, NATIONAL WILDLIFE FEDERATION” DATED 12/7/1995. THE SITE IS PROPOSING TO UTILIZE THE EXISTING DRY POND TO SATISFY THE SITE WATER QUANTITY REQUIREMENTS. PER DEQ GUIDANCE MEMO NO. 14-2014, THE SITE IS PERMITTED TO USE AN EXISTING STORMWATER MANAGEMENT FACILITY TO PROVIDE STORMWATER MANAGEMENT CONTROL IF THE LAND-USE ASSUMPTIONS UPON WHICH THE STORMWATER MANAGEMENT FACILITY WAS DESIGNED AND IMPLEMENTED REMAIN UNCHANGED. A WATERSHED ANALYSIS TO THE EXISTING DRY POND WAS COMPLETED, SEE SHEET 26. THIS ANALYSIS DEMONSTRATES THAT THE PROPOSED SITE IMPROVEMENTS DO NOT CHANGE THE INFLOW C-FACTOR OR DRAINAGE AREA INTO THE EXISTING DRY POND. THEREFORE, IT CAN BE CAN BE CONCLUDED THAT THE LAND USE ASSUMPTIONS UPON WHICH THE STORMWATER MANAGEMENT FACILITY WAS DESIGNED AND IMPLEMENTED REMAIN UNCHANGED. AS A RESULT, PER THE DEQ MEMO THE SITE IS PERMITTED TO USE THE STORMWATER MANAGEMENT FACILITY FOR WATER QUANTITY COMPLIANCE. PER SITE VISITS ON 11/1/22 AND 2/15/23 AND REVIEW OF THE EXISTING TOPOGRAPHIC SURVEY, THE DRY POND DOES NOT APPEAR TO BE CURRENTLY FUNCTIONING PER THE ORIGINAL DESIGN. THE DRY POND FOOTPRINT AND EMBANKMENT HAS BECOME OVERGROWN WITH WOODY VEGETATION AND THE DESIGN STORAGE CAPACITY APPEARS TO HAVE BEEN REDUCED THROUGH SEDIMENTATION OVER TIME. THIS PLAN PROPOSES TO RESTORE THE ORIGINAL DRY POND CAPACITY TO PROVIDE THE REQUIRED WATER QUANTITY CONTROL FOR THE PROPOSED IMPROVEMENTS. THE WOODY VEGETATION WILL BE CLEARED, THE ORIGINAL STAGE-STORAGE WILL BE REESTABLISHED, THE EMBANKMENT AND EMERGENCY SPILLWAY WILL BE RECONSTRUCTED, AND THE PRINCIPAL SPILLWAY CONDUIT WILL BE REPAIRED. SEE SHEET 08.Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CJ-130.DWG, 2/2/2024 10:42 AM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 WATER QUALITY COMPUTATIONS WATER QUALITY COMPUTATIONS27 C-CJ-130.DWG C-CJ-130 N/A N/A GORDON C. LETCHWORTH K. RYAN K. RYAN NUTRIENT CREDITS SHALL BE PURCHASED PRIOR TO OBTAINING COVERAGE UNDER THE DEQ CONSTRUCTION GENERAL PERMIT, ISSUANCE OF A FREDERICK COUNTY LAND DISTURBANCE PERMIT, AND ANY SITE DISTURBANCE. THIS AVAILABILITY LETTER CONFIRMS THERE ARE AVAILABLE CREDITS TO MEET THE SITE WATER QUALITY REQUIREMENTS AT THE TIME OF SITE PLAN APPROVAL FROM AN ELIGIBLE BANK. SEE COMPUTATIONS ON THIS SHEET FOR THE EXACT NUTRIENT CREDIT PURCHASE AMOUNT. SEE WATER QUALITY NARRATIVE ON THIS SHEET FOR FURTHER NUTRIENT CREDIT PURCHASE REQUIREMENTS. STORMWATER SPECIFICATIONS THESE NOTES APPLY TO THE FOLLOWING STORMWATER MANAGEMENT (SWM) FACILITIES: RECONSTRUCTED DRY POND SWM SUBMITTAL NOTES 1.CONTRACTOR TO PROVIDE TO THE ENGINEER AND OWNER SUBMITTALS FOR THE FOLLOWING SWM FACILITIES PRODUCTS FOR REVIEW AND APPROVAL PRIOR TO MANUFACTURING/ORDERING. SUBMITTALS SHALL INCLUDE PRODUCT DATA (NOT TECHNICAL SPECIFICATIONS) AND CURRENT TESTING RESULTS (LESS THAN 3 MONTHS OLD), AS APPLICABLE. a.POND LINER b.EMERGENCY SPILLWAY RIPRAP 2.CONTRACTOR TO PROVIDE TO THE ENGINEER AND OWNER A SHOP DRAWING PACKAGE FOR THE FOLLOWING SWM FACILITIES FOR REVIEW AND APPROVAL PRIOR TO MANUFACTURING. THE SHOP DRAWING PACKAGE SHALL BE SIGNED AND SEALED BY A QUALIFIED, LICENSED PROFESSIONAL ENGINEER IN THE COMMONWEALTH OF VIRGINIA AND INCLUDE SIGNED AND SEALED CONTRACT DRAWINGS, FABRICATION DRAWINGS, AND ASSOCIATED STRUCTURAL COMPUTATIONS. a.PRINCIPAL SPILLWAY SLIP LINING 3.APPROVAL OF THE SITE PLAN DOES NOT GRANT APPROVAL OF ANY STRUCTURAL INFORMATION SHOWN HEREIN. STRUCTURAL INFORMATION IS PROVIDED FOR INFORMATIONAL PURPOSES ONLY. STRUCTURAL DETAILS SHALL BE INCLUDED IN THE SHOP DRAWING PACKAGE FOR REVIEW AND APPROVAL PRIOR TO MANUFACTURING. 4.ALL SUBMITTED PRODUCTS SHALL MEET THE REQUIREMENTS PER THE DETAILS AND SPECIFICATIONS ON THIS PLAN SET AND PROJECT SPECIFICATIONS. CONTRACTOR SHALL COMPLY WITH ALL PROJECT SPECIFICATION REQUIREMENTS FOR SUBMISSION OF THESE PRODUCTS OR ADDITIONAL PRODUCT SUBMITTALS TO THE OTHER DESIGN CONSULTANTS. SWM INSTALLATION NOTES 1.CONTRACTOR SHALL STRICTLY ADHERE TO THE CONSTRUCTION SEQUENCING AND CONSTRUCTION INSPECTION PROCESS FROM THE COUNTY INSPECTOR AND CERTIFYING ENGINEER FOR THE RECONSTRUCTION OF THE DRY POND, AS DISCUSSED IN THE PRE-CONSTRUCTION MEETING. 2.CONTRACTOR SHALL STRICTLY ADHERE TO MANUFACTURER'S REQUIREMENTS FOR THE INSTALLATION OF ANY PROPRIETARY PRODUCTS. 3.CONTRACTOR SHALL ADHERE TO ALL GEOTECHNICAL REQUIREMENTS AS OUTLINED IN THE GEOTECHNICAL REPORT ISSUED BY ECS, DATED 10/16/2023, INCLUDING SPECIAL ATTENTION TO ALL DRY POND REQUIREMENTS IN SECTION 5.6 OF THE REPORT. SWM INSPECTION NOTES 1.THE RECONSTRUCTED DRY POND SHALL BE CONSTRUCTED UNDER THE SUPERVISION OF A COUNTY INSPECTOR AND CERTIFYING ENGINEER. THE CERTIFYING ENGINEER SHALL BE A QUALIFIED LICENSED PROFESSIONAL ENGINEER IN THE COMMONWEALTH OF VIRGINIA MEETING THE EXEMPTION REQUIREMENTS OF THE CODE OF VIRGINIA WITH EXPERTISE IN DRY POND FACILITY DESIGN. a.A QUALIFIED GEOTECHNICAL ENGINEER SHALL INSPECT AND CERTIFY THE POND EMBANKMENT, PRINCIPAL SPILLWAY, EMERGENCY SPILLWAY, AND EXCAVATION/LINER, SUBGRADE, BACKFILL. b.A QUALIFIED CIVIL ENGINEER SHALL INSPECT AND CERTIFY THE STORAGE AND ELEVATIONS OF THE SWM FACILITY. 2.THE CONTRACTOR SHALL SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE COUNTY INSPECTOR, CERTIFYING ENGINEER, ENGINEER OF RECORD (IF NOT THE CERTIFYING ENGINEER), OWNER, AND THE GEOTECHNICAL ENGINEER PRIOR TO COMMENCING ANY WORK ON THE DRY POND RECONSTRUCTION. 3.THE COUNTY INSPECTOR AND CERTIFYING ENGINEER SHALL OBSERVE AND DOCUMENT ALL STAGES OF THE FACILITY CONSTRUCTION AS OUTLINED IN THE CONSTRUCTION SEQUENCE AND AS ESTABLISHED DURING THE PRE-CONSTRUCTION MEETING. THE CONTRACTOR IS RESPONSIBLE FOR ALL NOTIFICATION TO THE COUNTY INSPECTOR AND CERTIFYING ENGINEER AT LEAST 72 HOURS PRIOR TO EACH REQUESTED INSPECTION. 4.THE CONTRACTOR SHALL OBTAIN AND PROVIDE ALL REQUESTED AS-BUILT INFORMATION FOR THE INTERNAL LAYERS OR COMPONENTS THAT WILL NOT BE ACCESSIBLE AFTER INSTALLATION TO THE COUNTY INSPECTOR AND CERTIFYING ENGINEER. THE CONTRACTOR SHALL PROVIDE ALL REQUESTED DELIVERY TICKETS AND FIELD TESTING RESULTS TO THE COUNTY INSPECTOR AND CERTIFYING ENGINEER. 5.THE CONTRACTOR SHALL NOTIFY THE COUNTY INSPECTOR, CERTIFYING ENGINEER, ENGINEER OF RECORD, AND OWNER OF ANY DEVIATIONS FROM THE APPROVED PLANS FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 6.THESE INSPECTIONS DO NOT RELIEVE THE CONTRACTOR FROM INSTALLING RECONSTRUCTED DRY POND IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND CONTRACT DRAWINGS, AND IN ACCORDANCE WITH INDUSTRY STANDARDS, MEANS, AND METHODS. THESE INSPECTIONS DO NOT RELIEVE THE SITE AS-BUILT REQUIREMENTS RELATED TO THE STORM SEWER AND/OR STORMWATER MANAGEMENT FACILITIES. SWM AS-BUILT NOTES GENERAL 1.THE CONTRACTOR SHALL OBTAIN ANY SWM FACILITY AS-BUILT INFORMATION THAT WILL NOT BE ACCESSIBLE AFTER CONSTRUCTION IS COMPLETE, INCLUDING, BUT NOT LIMITED TO, EMBANKMENT CORES AND PRINCIPAL SPILLWAY SLIP LINING. 2.A SWM AS-BUILT IS REQUIRED. THE SWM AS-BUILT SHOULD MINIMALLY INCLUDE THE FOLLOWING INFORMATION: a.LOCATIONS OF ALL STORM SEWER WITH MATERIALS, SIZES, LENGTHS, SLOPES, AND INVERTS b.TOPOGRAPHIC SURVEY OF THE RECONSTRUCTED DRY POND, INCLUDING INFORMATION ON THE PRINCIPAL AND EMERGENCY SPILLWAY MATERIALS, SIZES, LENGTHS, SLOPES, AND INVERTS c.ANY OTHER APPLICABLE COUNTY AS-BUILTS REQUIREMENTS d.SIGN AND SEAL BY A LICENSED SURVEYOR OR LICENSED PROFESSIONAL ENGINEER IN THE COMMONWEALTH OF VIRGINIA. 3.A SWM CERTIFICATION IS REQUIRED FOR THE SWM FACILITIES. THE SWM CERTIFICATION SHALL CERTIFY THAT THE RECONSTRUCTED DRY POND HAS BEEN CONSTRUCTED IN ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS AND MINIMALLY INCLUDING THE FOLLOWING: a.CONSTRUCTION PICTURES FOR ALL MILESTONES OF SWM FACILITY INSTALLATION b.MATERIAL DELIVERY TICKETS c.OTHER SUPPORTING DOCUMENTATION i.INSPECTION REPORTS BY OTHERS d.SIGN AND SEAL BY A LICENSED PROFESSIONAL ENGINEER IN THE COMMONWEALTH OF VIRGINIA 4.PER THE DEQ CONSTRUCTION GENERAL PERMIT NOTICE OF TERMINATION REQUIREMENTS, AN ENGINEER'S CERTIFICATION IS REQUIRED TO BE COMPLETED AND SUBMITTED WITH THE NOTICE OF TERMINATION. SEE ENGINEER'S CERTIFICATION ON THIS SHEET. 5.THE CONSTRUCTION GENERAL PERMIT NOTICE OF TERMINATION SHALL NOT BE SUBMITTED UNTIL THE SWM AS-BUILT AND SWM CERTIFICATION ARE APPROVED BY THE COUNTY. SWM MAINTENANCE NOTES 1.THE OWNER SHALL BE RESPONSIBLE FOR MAINTENANCE OF THE RECONSTRUCTED DRY POND. 2.THE RECONSTRUCTED DRY POND SHALL BE INSPECTED PERIODICALLY (AT LEAST ANNUALLY) TO DOCUMENT MAINTENANCE AND REPAIR NEEDS. 3.SEE ROUTINE MAINTENANCE ITEMS ON THIS SHEET.Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\C-CJ-140.DWG, 2/2/2024 10:42 AM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 STORMWATER SPECIFICATIONS28 C-CJ-140.DWG C-CJ-140 N/A N/A GORDON C. LETCHWORTH K. RYAN K. RYAN DEQ CONSTRUCTION GENERAL PERMIT ENGINEER'S CERTIFICATION VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 TYSON DRIVE - ROUTE 863 80' RIGHT-OF-WAY DB. 733 PG. 517 SA CO MB MBMB MB LP MBMB LP LP LP LP LP LP LP LP LP OHEC TEL BX TR TR TR TR TR TEL BX RD RD RD RD EX.1 EX.2 EX.3 EX.4 EX.5 EX.6 EX. 10 WV ACACAC C E TR E AC E SIGN SIGN SIGN WxWxWx75' FRONT YARD SETBACK 25' REAR YARD SETBACK 25' SIDE YARD SETBACK25' SIDE YARD SETBACKWx Wx Wx Wx WxWxWxWx719718718717718 719 720 721 722 723 7 2 4 725 725720720722723724720722723724723724 725 728 729725 724725732730724 725 730 735 735 732 732 734 735736732725730 735 740 740 740 735 741745740735735740740740735740 735 730725 725730735740745739738735730730735 735 740 740 73 5 730727 725 725720729 730 716717717720725 724720720720716716718719720720720725725721 72 4 720 720 722 723 724 724725726 724 722 71971971872071571571 9 720718718720 718717715715718719717 714715 716 718 718 717 717 718 718 715715 720720 7 2 1 722 724 723 723 722 724 721 724 722 716 719718720716 716 720 714714715 715 716 717715 714715 713 714 717LCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCG LC G LCG LCGLCG LCG LCG LCG LCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCG LCG LCG LCG LCG LCG LCG LCG LCG (1) GB 3" Cal. (2) QC 3" Cal. (3) NS 3" Cal. (3) LS 3" Cal. (3) QP 3" Cal. (3) AR 3" Cal. (3) QP 3" Cal. (3) TA 3" Cal. (3) NS 3" Cal. (3) QC 3" Cal. (3) AR 3" Cal. (3) QC 3" Cal. (3) TA 3" Cal. (3) NS 3" Cal. (5) QP 3" Cal. (3) NS 3" Cal. (3) QC 3" Cal. (2) AR 3" Cal. (2) QP 3" Cal. (3) TA 3" Cal. (2) QP 3" Cal. (2) AR 3" Cal. (3) TA 3" Cal. (1) GB 3" Cal. (1) GB 3" Cal. (1) GB 3" Cal. (4) LS 3" Cal. (4) GB 3" Cal. LEGEND IMPERVIOUS SURFACE PARKING AREA PROPOSED TREE PROPOSED INTERIOR PARKING TREE EXISTING INTERIOR PARKING TREE LANDSCAPE PLAN OVERALL29 L-LS-101.DWG L-LS-101 1" = 20' SBH BTV BTV CEKGordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\L-LS-101.DWG, 2/2/2024 1:57 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 LAN DSCAPE A R C H ITECTLic. No. 000851 DOUGLAS L. KOESERCOMMONWEALTHOF VI R GI NIASHEET 30 SHEET 31 GRAPHICAL SCALE: 1" = 60' 60 30 0 60 120 180 IPF SA CO LP LP LP LP LP TR TR RD RD RD RD EX. 5 EX. 6 EX. 10 C E AC E SIGN WxWxN42°25'47"E 660.00'WxWxWx724 729725 724725732730724 725 730 735 735 732 732 734 735736732725730 735 740 740 740 735 741745735740740740735740 735 730725 725730735745730735 72572071671771772072 5 720720725725721 72 4 720 720 722 723 724 724725 726 724 722 719719718717LCGLCG LCGLCGLCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCG LCG LCG LCG LCG LCG LCG LC G LCG LCG LCGLCG LCG LCG LCG LCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCG (1) GB 3" Cal. (2) QC 3" Cal. (3) NS 3" Cal. (3) LS 3" Cal. (3) QP 3" Cal. (3) AR 3" Cal. (3) QP 3" Cal. (3) TA 3" Cal. (3) NS 3" Cal. (3) QC 3" Cal. (3) AR 3" Cal. (3) QC 3" Cal. (3) TA 3" Cal. (1) GB 3" Cal. (4) LS 3" Cal. (4) GB 3" Cal. LEGEND IMPERVIOUS SURFACE PARKING AREA PROPOSED TREE PROPOSED INTERIOR PARKING TREE EXISTING INTERIOR PARKING TREE VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3LANDSCAPE PLAN30 L-LS-101.DWG L-LS-101 1" = 20' SBH BTV BTV CEKGordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\L-LS-101.DWG, 2/2/2024 1:57 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 G:\PROJECT\ENGIN\3611\0101\PLANS\L-LS-101.DWG, 2/2/2024 1:57 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 MATCH LINE SEE SHEET 31 GRAPHICAL SCALE: 1" = 30' 30 15 0 30 60 90 LAN DSCAPE A R C H ITECTLic. No. 000851 DOUGLAS L. KOESERCOMMONWEALTHOF VI R GI NIA IPFIPF TYSON DRIVE - ROUTE 863 80' RIGHT-OF-WAY DB. 733 PG. 517 MB MBMB MB LP MBMB LP LP LP LP OHEOHEOHEC TEL BX TR TR TR TR TEL BX EX. 3 EX. 4 EX. 5 WV ACACAC TR E AC E SIGN SIGN WxWxWxWxWxN47°34'13"W 990.00'S42°25'47"W 660.00'S47°34'13"E 990.00'Wx Wx Wx Wx Wx Wx Wx Wx WxWxWxWxWxWx719718 718717 718 719 720 721 722 723 7 2 4 725 725720720724720722723724723717717720720720716716718719720720719718715715719 720718718718717715715718719717 714 715 716 718 718 717 717 718 718 715 715 720720 7 2 1 722 724 723 723 722 724 721 724 722 716 718720716 716 720 714 714 715 715 716 717715 714 715 713 714 LCGLCG LCGLCG LCG LCG LCG LCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCGLCG LCG LCG LCG LCG LCG LCG (3) QC 3" Cal. (3) TA 3" Cal. (3) NS 3" Cal. (5) QP 3" Cal. (3) NS 3" Cal. (3) QC 3" Cal. (2) AR 3" Cal. (2) QP 3" Cal. (3) TA 3" Cal. (2) QP 3" Cal. (2) AR 3" Cal. (1) GB 3" Cal. (1) GB 3" Cal. LEGEND IMPERVIOUS SURFACE PARKING AREA PROPOSED TREE PROPOSED INTERIOR PARKING TREE EXISTING INTERIOR PARKING TREE VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3LANDSCAPE PLAN31 L-LS-101.DWG L-LS-101 1" = 20' SBH BTV BTV CEKGordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\L-LS-101.DWG, 2/2/2024 1:57 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 LAN DSCAPE A R C H ITECTLic. No. 000851 DOUGLAS L. KOESERCOMMONWEALTHOF VI R GI NIAMATCH LINE SEE SHEET 30 GRAPHICAL SCALE: 1" = 30' 30 15 0 30 60 90 LAN DSCAPE A R C H ITECTLic. No. 000851 DOUGLAS L. KOESERCOMMONWEALTHOF VI R GI NIA PLANTING HOLE 2-3X WIDTH OF ROOT BALL SOIL PEDESTAL UNDISTURBED NOTES: 1. STAKING AND GUYING MAY BE REQUIRED TO COUNTER HIGH WINDS, SOIL SETTLEMENT, STEEP SLOPES, VANDALISM, OR OTHER CONDITIONS THREATENING TREE HEALTH OR SUITABLE GROWTH PATTERNS. 2. AT TIME OF PLANTING PRUNE ONLY CROSSING LIMBS, BROKEN OR DEAD BRANCHES, AND ANY BRANCHES THAT POSE A HAZARD TO PEDESTRIANS. 3" (7.5 CM) TEMPORARY SOIL SAUCER TOP OF ROOTBALL TO BE SET 10% ABOVE THE LEVEL OF SURROUNDING SOIL REMOVE ALL WIRE, PLASTIC, ROPE, AND BURLAP (NATURAL AND SYNTHETIC) FROM TOP HALF OF ROOT BALL AND FROM SITE. IF CONTAINER GOWN, REMOVE CONTAINER AND CUT CIRCLING ROOTS. BACKFILL WITH 1/2 CLEAN EXISTING SOIL, 1/4 CERTIFIED TOPSOIL, AND 1/4 ORGANIC MATERIAL APPROVED BY THE LANDSCAPE ARCHITECT REMOVE TAGS, LABELS, AND PLASTIC SLEEVING. DO NOT STAKE UNLESS SPECIFIED (SEE NOTE). DO NOT WRAP TRUNK. PRUNE SUCKERS 3" (7.5 CM) MULCH, DO NOT PLACE MULCH ADJACENT TO TRUNK THREE STRANDS OF GALVANIZED WIRE GUY 12 GAUGE. ALLOW FOR SLIGHT AMOUNT OF MOVEMENT. 8 FT x 2 IN x 2 IN (2.4 M x 5 CM x 5 CM) HARDWOOD STAKE, 2 FT-6 IN (0.8 M) MIN. BELOW SURFACE. STAKE SHALL BE DRIVEN A MIN. 18 IN (46 CM) OUT FROM TRUNK AND OUTSIDE OF ROOTBALL. INCORPORATE SLOW-RELEASE GRANULAR FERTILIZER PLAN VIEW OF GUYING WIRE LAYOUT 12 GAUGE GALVANIZED WIRE THREE 2 IN x 2 IN (5 CM x 5 CM) HARDWOOD STAKES DECIDUOUS TREE PLANTING DETAIL LANDSCAPE CALCULATIONS AND DETAILS32 L-LS-101.DWG L-LS-101 1" = 20' SBH BTV BTV CEKGordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:2022310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA32 3611-0101 FINAL SITE PLAN FEBRUARY 2024 G:\PROJECT\ENGIN\3611\0101\PLANS\L-LS-101.DWG, 2/2/2024 1:57 PM, bvellozzi VERT. DATUM: NAVD 88 HORIZ. DATUM: NAD 83 LANDSCAPE PLANTING DETAILS NOTES: 1.THERE IS NO BUFFER REQUIREMENT FOR THIS SITE, DUE TO ADJACENT PARCELS BEING ZONED M1, RESULTING IN AN M1 TO M1 LAND USE BUFFER. 2.ALL LANDSCAPING WILL CONFORM TO THE REQUIREMENTS AND BE IN GENERAL CONFORMANCE WITH THE FREDERICK COUNTY ZONING ORDINANCE §165-203.01B 3.ALL LAWN AREAS WILL BE SEEDED. TALL FESCUE MIXTURE SHALL BE USED IN MOST AREAS. THE MIXTURE IS TO BE 80% CERTIFIED TURF-TYPE TALL FESCUE, 10% CERTIFIED BLUEGRASS, AND 10% PERENNIAL RYEGRASS. SUBSTITUTION OF SEED TYPE OR PERCENT ONLY ON APPROVAL OF OWNER/LANDSCAPE ARCHITECT. SEED TO BE FREE OF NOXIOUS WEED SEED. REFER TO THE MARYLAND-VIRGINIA TURFGRASS VARIETY RECOMMENDATION WORK GROUP FOR CATEGORY 1 TALL FESCUE AND KENTUCKY BLUEGRASS TURF VARIETY RECOMMENDATIONS. 4.NO TREES OR SHRUBS SHALL BE PLACED ON FREDERICK WATER EASEMENTS.LAN DSCAPE A R C H ITECTLic. No. 000851 DOUGLAS L. KOESERCOMMONWEALTHOF VI R GI NIA*EIGHT (8) TREES ARE USED FOR INTERIOR PARKING REQUIREMENT