Loading...
32-23 Site PlanAERIAL MAPVICINITY MAP ENGINEER OF RECORDDO NOT SCALE DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK. CALL BEFORE YOU DIG CONTRACTOR SHALL COMPLETE INSTALL PER THE SIGNED AND THE SEALED SET OF DRAWINGS. ANY NECESSARY DEVIATIONS FROM THE DRAWINGS MUST BE SUBMITTED THROUGH AN RFI REQUEST PROCESS WITH ENGINEERING FOR AN APPROVAL PRIOR TO CONTRACTOR PROCEEDING WITH A DEVIATION OF THE SIGNED AND SEALED SET OF DRAWINGS. CONTRACTOR NOTE SITE P78147 INSTALLATION OF ELECTRIC VEHICLES CHARGING EQUIPMENT FLYING J 752 1530 REST CHURCH RD WINCHESTER, VA 22624 CHARGING STATIONS COORDINATES: 39.290787, -78.086153 WINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 SITE CS COVER SHEET APPROVED BY THE FREDERICK COUNTY ZONING ADMINISTRATOR SITE PLAN VALID FOR FIVE (5) YEARS FROM APPROVAL DATE PROPERTY INFORMATION PFJ SOUTH EAST LLC5508 LONAS DRIVEKNOXVILLE, TN 37909 OWNER: 865-474-3421 FREDERICK COUNTY PIN: 33 9 1 UTILITY PROVIDER (FOR THIS SCOPE OF WORK):SHENANDOAH VALLEY ELECTRICAL COOP180 OAKWOOD DRIVEROCKINGHAM, VA 22801540-450-2041 MAGISTERIAL DISTRICT: STONEWALL TOTAL LAND AREA: 24.98 ACRES DEVELOPED AREA IN THIS PLAN: 1200 SF (EXISTING PARKING LOT) ZONED: B3 INDUSTRIAL TRANSITION DISTRICT PRESENT USE: TRUCK STOP AND PLAZAPROPOSED USE: TRUCK STOP AND PLAZA PROPOSED WORK: ADDITION OF 2 EV CHARGING STALLS IN THE EXISTING LOT TOTAL NEW LAND DISTRUBANCE 180 SF PREVIOUSLY APPROVED PLANS: REX #04-95, SP #26-96, SP#54-04, SP #01-10, SP #14-15 & SP #34-16 LAND DEVELOPER AND DESIGNER : OSCAR W LARSON COMPANY 10100 DIXIE HIGHWAY CLARKSTON, MI 48348 CONTRACTOR PHILLIP JAMINET PE#44251 OSCAR W. LARSON COMPANY THE OSCAR W. LARSON COMPANY ZACHARY COSBY 330-716-2705 10100 DIXIE HWY CLARKSTON, MI 48348 PROJECT DESCRIPTION SHEET NO.SHEET TITLE REV NO. 1 1 0 0 0 0 0 COVER SHEET & PROJECT INFORMATIONCS OVERALL SITE PLANC-1 DEMOLITION SITE PLAN ENLARGED SITE PLAN DETAILS DETAILS DETAILS DRAWING INDEX INSTALL (2) 350KW DELTA DISPENSERS AND SUPPORT EQUIPMENT IN A FOUR STALL PULL IN CONFIGURATION WITHOUT A CANOPY. ELECTRICAL EQUIPMENT INSTALLED ADJACENT TO STALLS TO PROVIDE POWER TO THE DISPENSERS THERE WILL BE NO CHANGE TO THE CURRENT LAND USE, THIS IS AN IMPROVEMENT TO THE EXISTING PARKING LOT. THERE ARE NO CHANGES TO TO ANY EXISTING (PREVIOUSLY APPROVED) LANDSCAPING, OR SIGNAGE. THERE ARE NO ADDITIONAL MEDIA SIGNS BEING PROPOSED FOR THIS PROJECT. SITE PLAN REFERENCE NUMBER - SP# 32-23 ELECTRICAL UTILITY PLAN 0 ELECTRICAL ENLARGED SITE PLAN 0 ELECTRICAL SINGLE LINE DIAGRAM 1 ELECTRICAL CONDUIT DETAILS 0 ELECTRICAL SPECIFICATIONS 0 0ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES 0 ELECTRICAL GROUNDING DETAILS ELECTRICAL GENERAL CONSTRUCTION NOTES 0 C-2 C-3 D-1 D-2 D-3 E-1 E-2 E-3 E-4 E-5 E-6 G-1 GN-1 0EV POWER & DISPENSER STATIONS CUTSHEETSE-7 CODE INFORMATION STATE JURISDICTION LATEST ELECTRICAL CODE, INCLUDING THE TABLES AND ANNEXES THERETO. STATE JURISDICTION LATEST BUILDING CODE, INCLUDING THE TABLES AND ANNEXES THERETO. STATE JURISDICTION LATEST ENERGY CODE, INCLUDING THE TABLES AND ANNEXES THERETO. STATE JURISDICTION LATEST REFERENCED STANDARDS CODE, INCLUDING THE TABLES AND ANNEXES THERETO. PROPERTY SURVEY (FOR REFERENCE ONLY) PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A WINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 C-1 OVERALL SITE PLAN OVERALL SITE PLAN SCALE: 1" = 50' PARKING ANALYSIS TOTAL EXISTING STALLS: 144 EXISTING ADA STALLS: 6 PROPOSED STALLS: 137 REQUIRED STALLS: 1:400 GFA (CONVENIENCE STORE) 1:100 GFA (RESTAURANT) GROSS FLOOR AREA: 20,520 (16,520 STORE, 4000 RESTAURANT) REQUIRED STALLS: 81PROPOSED ADA STALLS: 7 PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A WINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 C-2 DEMOLITION PLAN LEGEND MATERIAL AMOUNT UNITS ASPHALT 122 SQ FT PARKING LINES 137 LIN FT CONCRETE CURB 79 LIN FT LANDSCAPING 82 SQ FT CONCRETE SIDEWALK 0 SQ FT DEMO QUANTITIES TABLE NOTES 1. THE CONTRACTOR SHALL HAVE ALL UTILITIES LOCATED PRIOR TO BEGINNING WORK 2. THE CONTRACTOR SHALL RETURN SIDEWALKS, LANDSCAPING PLANTERS, IRRIGATION SYSTEMS, AND ANY OTHER FACILITIES DISTURBED BY THE WORK TO THE SAME OR BETTER CONDITION THAN EXISTED PRIOR TO THE COMMENCEMENT OF THE WORK. 3. ALL QUANTITIES LISTED IN THE DEMOLITION QUANTITIES TABLE ARE ONLY APPROXIMATIONS. THE CONTRACTOR SHALL VERIFY ALL QUANTITIES BEFORE DEMOLITION. 4. ALL EXCAVATED MATERIALS ARE TO BE DISPOSED/STOCKPILED IN A LEGAL MANNER. 5. DUST CONTROL TO BE USED AS NEEDED. 6. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK BEGINNING. DEMOLITION SITE PLAN SCALE: 1/8" = 1'-0" PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A NOPARKINGNOPARKINGNOPARKINGWINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 C-3 ENLARGED SITE PLAN EQUIPMENT BOLLARD TYPE: FRONT BOLLARD TYPE: REAR BOLLARD TYPE: SIDE EV-1 DELTA 350KW EV-2 DELTA 350KW TRANSFORMER SWITCHBOARD PC-1 PC-2 MINI POWER ZONE FIXED FIXED FIXED FIXED N/A FIXED FIXED N/A N/A FIXED FIXED N/A N/A N/A BOLLARD SCHEDULE PARKING STALL SCHEDULE EXISTING STALLS PROPOSED EV STANDARD STALLS PROPOSED EV VAN ACCESSIBLE ADA STALLS NET STALL COUNT 11 2 2 -7 NOTES FIXED N/A ENLARGED SITE PLAN SCALE: 1/8" = 1'-0" PROPOSED EV STANDARD ADA STALLS FIXED FIXEDFIXED FIXED N/A FIXED PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A WINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 AND CONDUIT ENTRY DETAIL (350KW) NO SCALE POWER CABINET ANCHORAGE D-2 B DISPENSER FOOTING DETAIL (350KW) NO SCALE DISPENSER DETAIL (350KW) NO SCALE POWER UNIT DETAIL (350KW) NO SCALE D-1 DETAILS SWITCHBOARD MOUNTING DETAIL NO SCALE AND CONDUIT ENTRY DETAIL (200KW) NO SCALE DISTRIBUTION CABINET ANCHORAGE PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A WINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 D-2 DETAILS 6" WARNING BOLLARD DETAIL NO SCALE 6" REMOVABLE LOCKING BOLLARD DETAIL NO SCALE NO PARKING EVCS ACCESSIBLE STALL MARKING PLAN NO SCALE STANDARD STALL MARKINGS DETAIL NO SCALE CONCRETE CURB NO SCALE CONCRETE PAD DETAIL NO SCALE NO PARKING PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A WINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 D-3 DETAILS TOP 6" WARNING BOLLARD WITH SIGN DETAIL NO SCALE MAIN BREAKER FUNCTION AS EMERGENCY DISCONNECT FOR POWER TO CHARGING STATIONS EMERGENCY DISCONNECT/ MAIN BREAKER LOCATED INSIDE EMERGENCY DISCONNECT SIGN DETAIL NO SCALE LIGHT POLE MOUNTING DETAIL NO SCALE LIGHT POLE BASE DETAIL 1/2" = 1'-0" NOT USED NO SCALE NOT USED NO SCALE PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A NOPARKINGNOPARKINGNOPARKINGWINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 E-1 ELECTRICAL UTILITY PLAN GENERAL NOTES ELECTRICAL UTILITY PLAN SCALE: 3/32" = 1'-0" 1. THE UTILITY DESIGN DETAILS SUMMARIZED ON THIS SHEET ARE FOR PROPERTY OWNER REVIEW. THE CONTRACTOR SHALL REFERENCE THE UTILITY DESIGN PACKAGE, PROVIDED WITH THE "ISSUED FOR CONSTRUCTION" DRAWINGS. THE CONTRACTOR SHALL INSTALL THE UTILITY RELATED SCOPE OF WORK PER UTILITY CONSTRUCTION SPECIFICATION REQUIREMENTS. 2. UTILITY EQUIPMENT INSTALLATION AND PREP WORK AND TERMINATION OF SERVICE CONDUCTORS SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY ENGINEER AT TIME OF PRE-CONSTRUCTION MEETING TO ENSURE ACCURACY OF INSTALLATIONS 3. FOR GENERAL NOTES AND SYMBOL LIST, SEE E-6 4. BEFORE BID SUBMISSION AND COMMENCING WORK, CONTRACTOR SHALL FIELD INSPECT SCOPE OF PROJECT, AND SUBMIT A REQUEST FOR INFORMATION TO THE ENGINEER FOR ANY DISCREPANCIES OR INCOMPATIBILITIES FOUND BETWEEN DESIGN AND ACTUAL CONDITIONS. 5. ALL JUNCTION OR OUTLET BOXES SHALL BE INSTALLED SO AS TO ALLOW ACCESS TO COVER. PROVIDE APPROVED ACCESS DOORS OR PLATES AS REQUIRED IN AREAS WHERE UNOBSTRUCTED ACCESS TO BOX OR OUTLET IS NOT POSSIBLE 6. EQUIPMENT LOCATIONS, WHERE SHOWN, ARE APPROXIMATE. FIELD CONTRACTOR SHALL VERIFY AND COORDINATE WITH OWNER, INCLUDING OTHER CONSTRUCTION RELATED INFORMATION. 7. ALL WORKS SHALL BE PERFORMED AS PER LATEST EDITION OF NEC, AND LATEST LOCAL UTILITY SPECIFICATIONS. KEYNOTES PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A NOPARKINGNOPARKINGNOPARKINGWINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 E-2 ELECTRICAL ENLARGED SITE PLAN ELECTRICAL SITE PLAN SCALE: 1/8" = 1'-0" GENERAL NOTES 1. CONDUIT ROUTING IS DIAGRAMMATICALLY SHOWN ON PLANS AND ARE ONLY APPROXIMATIONS. THE EXACT LOCATION AND ROUTING PATHS SHALL BE FIELD VERIFIED AND INSTALLED PER JURISDICTIONAL REQUIREMENTS PRIOR TO DIGGING TRENCHING. 2. ALL ELECTRICAL WORK AND RELATED ACTIVITIES PERFORMED ONSITE SHALL BE DONE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE (NEC), LOCAL CODES AND APPLICABLE STANDARDS. 3. UTILITY EQUIPMENT INSTALLATIONS AND PREP WORK SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY ENGINEER TO ENSURE ACCURACY OF INSTALLATIONS. KEYNOTES 1. PROPOSED LOCATION OF BOLLARD 2. PROPOSED DELTA 350kW EV CHARGER DISPENSER 3. PROPOSED LOCATION FOR UTILITY TRANSFORMER 4. PROPOSED MINI POWER ZONE 5. PROPOSED DELTA 350kW POWER CABINET 6. PROPOSED SWITCHGEAR ASSEMBLY (OWNER FURNISHED-CONTRACTOR-INSTALLED). COMES WITH BUILT-IN UTILITY METERING COMPARTMENT & INCOMING CABLE PULL SECTION 7. PROVIDE CONDUIT(S) AND WIRING PER POWER RISER, REFER TO DRAWING E-4 FOR ADDITIONAL INFORMATION PROPOSED EQUIPMENT SCHEDULE QTY EQUIPMENT PART #DESCRIPTION 2 2 1 1 1 DELTA 350kW POWER CABINET DELTA 350kW DISPENSER MINI POWER ZONE SWITCHGEAR UTILITY TRANSFORMER 350kW EV CHARGER CABINET 350kW EV CHARGE DISPENSER 15kVA TRANSFORMER W/ 480-120V/208V PANEL BOARD 1200A BUS 480Y/277V, 3Ø, 4W 65KAIC, NEMA 3R TBD SUPPLIED BY OTHERS SUPPLIED BY OTHERS SUPPLIED BY OTHERS SUPPLIED BY OTHERS SUPPLIED BY OTHERS PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A WINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 E-3 ELECTRICAL SINGLE LINE DIAGRAM ELECTRICAL RISER DIAGRAM NO SCALE PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A WINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 E-4 ELECTRICAL CONDUIT DETAILS CONDUIT ELEVATION - POWER DISTRIBUTION, POWER UNIT, DISPENSER (FOR REFERENCE ONLY) NO SCALE CONDUIT UNDER SOIL TRENCH NO SCALE TYPICAL NON-UTILITY CONDUIT UNDER ASPHALT TRENCH NO SCALE TYPICAL NON-UTILITY PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A WINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 E-5 ELECTRICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A WINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 E-6 ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES ELECTRICAL GENERAL NOTES ABBREVIATIONS SYMBOL DESCRIPTION CIRCUIT BREAKER "##A" - INDICATES AMPERAGE RATING "#P" - INDICATES NUMBER OF POLES FUSED DISCONNECT SWITCH "##AS" - INDICATES SWITCH SIZE "##AF" - INDICATES FUSE SIZE NON-FUSED DISCONNECT SWITCH "#A" - INDICATES SWITCH SIZE "#P" - INDICATES NUMBER OF POLES TRANSFORMER, 480V INDICATES PRIMARY VOLTAGE, 120/208V INDICATES SECONDARY VOLTAGE GROUNDING CONNECTION PANELBOARD - REFER TO PANELBOARD SCHEDULES FOR ADDITIONAL INFORMATION ##A/#P ##AS ##AF #A/#P 480Δ 120Y/208V SYMBOL DESCRIPTION UON, 20A, 125V, 2P, 3W, GROUNDED WALL MOUNTED DUPLEX AND DOUBLE DUPLEX RECEPTACLES, NEMA 5-20R. (COLOR PER ARCHITECT). ALL OUTLETS SHALL BE LABELED WITH ITS SOURCE PANEL AND BREAKER # ID. "WP" - INDICATES WEATHERPROOF (TYP FOR WIRING DEVICES) "C" - INDICATES COUNTER HEIGHT (TYP FOR WIRING DEVICES) SHADING FOR DUPLEX OR DOUBLE DUPLEX PER ABOVE INDICATES DEDICATED CIRCUIT UON, 20A, 125V, 2P, 3W, GROUNDED WALL MOUNTED DUPLEX AND DOUBLE DUPLEX RECEPTACLES WITH GROUND FAULT CIRCUIT INTERRUPTER, NEMA 5-20R. WEATHER PROOF (COLOR PER ARCHITECT). ALL OUTLETS SHALL BE LABELED WITH ITS SOURCE PANEL AND BREAKER # ID. ELECTRICAL JUNCTION BOX FOR HARDWIRED EQUIPMENT. (2) INDICATES DOUBLE-GANG BOX. (F) INDICATES FLOOR RECESSED. (CE) INDICATES CEILING RECESSED. (AFC) INDICATES ABOVE FINISHED CEILING, SURFACE MTD. SURFACE MOUNTED PANELBOARD - SOLID INDICATES NEW, UNSHADED/DASHED INDICATES EXISTING DRY TYPE TRANSFORMER - SIZE AS INDICATED ON THE DRAWINGS ELECTRICAL METER OR SUB-METER AS IDENTIFIED ON THE DRAWINGS ONE, TWO, OR THREE HOME RUNS TO ELECTRICAL PANEL 'PNL' - INDICATED PANEL NAME '#' - INDICATES CIRCUIT NUMBER, U.O.N. GROUND BAR J T MMM PNL-(#)1 CKT 2 CKT 3 CKT PNL-(#),(#) PNL-(#),(#),(#) G POWER AND SIGNAL DEVICE LEGEND ONE LINE/RISER DIAGRAM LEGEND OR 600V PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A WINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 E-7 EV POWER & DISPENSER STATIONS CUTSHEETS PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A WINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 G-1 ELECTRICAL GROUNDING DETAILS GROUNDING SCHEMATIC NO SCALE CADWELD CONNECTIONS OR ENGINEER APPROVED EQUAL TEE CONNECTION HORIZONTAL CABLE TAP TO VERTICAL REBAR BURNDY CONNECTIONS OR ENGINEER APPROVED EQUAL HORIZONTAL STEEL SURFACE TO FLAT STEEL SURFACE OR HORIZONTAL PIPE TYPE HS PARALLEL HORIZONTAL CONDUCTORS PARALLEL DEAD END TAP OR HORIZONTAL THRU CONDUCTOR TYPE PC CABLE TO REBAR TYPE RJ HORIZONTAL SPLICE TYPE SS SPLICE OF HORIZONTAL CABLES PARALLEL HORIZONTAL CONDUCTORS PARALLEL THROUGH CONNECTION OF HORIZONTAL CABLES TYPE PT FIELD FABRICATED GREEN STRANDED INSULATED TWO HOLE - LONG BARREL LENGTH COPPER LUGS TYPE YA-2 TEE OF HORIZONTAL RUN AND TAP CABLES HORIZONTAL TEE TYPE TA THROUGH CABLE TO GROUND ROD THROUGH CABLE TO TOP OF GROUND ROD TYPE GT BOND JUMPER TYPE 2-YA-2 CABLE DOWN AT 45° TO RANGE OF VERTICAL PIPES VERTICAL PIPE TYPE VS VERTICAL STEEL SURFACE TYPE VS CABLE DOWN AT 45° TO VERTICAL STEEL SURFACE INCLUDING PIPE SEE PLAN PROPOSED CONCRETE #4 AWG BARE Cu GROUNDING ELECTRODE CONDUCTOR SEE NOTE 1 GRADE NON-METALLIC PROTECTIVE SLEEVE LISTED CONNECTION PROPOSED CONCRETE PAD IN DIRECT CONTACT WITH EARTH PROPOSED COMPACTED CLEAN GRAVEL CONCRETE ENCASED ELECTRODE DETAIL NO SCALE CONCRETE ENCASED ELECTRODE DETAIL NO SCALE PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A WINCHESTER, VA 22624P78147 - FLYING J 7521530 REST CHURCH RD101000 DIXIE HWY. CLARKSTON, MI 48348 330-716-2705 GN-1 ELECTRICAL GENERAL CONSTRUCTION NOTES GENERAL CONSTRUCTION NOTES GENERAL CONSTRUCTION NOTES CONT. ELECTRICAL NOTES ELECTRICAL NOTES CONT. PHILLIP J. JAMINET Lic. No. 44251P ROFESS I ON A L E N G INEERCOMMONW E A L T H OF VI R G I NI A !ENGINEERING DESIGN SURVEYSITE NAME:P78147 Flying J #752!(717) 938-359160 MAPLEWOOD DR. ETTERS, PA 17319VICINITY MAP SITE 5/22/2023