Loading...
34-23 Site PlanLAKE FREDERICK VICINITY MAP Scale: 1" = 2000' LEGEND WATER TREATMENT FACILITY FREDERICK COUNTY, VIRGINIA WATER LINE ASPHALT PAVEMENT WORKING DAYS NOTICE PROTECT YOURSELF, GIVE THREE "811" OVERLAY EXISTING PAVEMENT SURVEY NOTES: OPEQUON MAGISTERIAL DISTRICT FILE DISCLAIMER: IF THESE FILES ARE MODIFIED AFTER RECEIVED, THE RECEIVER AGREES TO INDEMNIFY, DEFEND AND HOLD HARMLESS, OUR FIRM "RK&K", FROM AND AGAINST ANY AND ALL CLAIMS, SUITS, LOSSES, DAMAGES OR COSTS FROM THE USE OF OUTDATED DESIGN FILES. THE OFFICIAL DOCUMENTS OF RECORD ARE THE PAPER, MYLAR, OR VELLUM DOCUMENTS WHICH BEAR THE COMPANY SEAL AND SIGNATURES. IF DIGITAL FILES HAVE BEEN PROVIDED TO THE CLIENT AND/OR CONTRACTOR, THOSE FILES ARE FOR CONVENIENCE ONLY AND DO NOT SUPERCEDE THE SIGNED PLAN SET.Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTIONCOVER SHEET AND INDEX OF DRAWINGSG-011.THE INFORMATION SHOWN HEREON IS BASED ON AN ACTUAL FIELD SURVEY COMPLETED SEPTEMBER 29, 2020. BOUNDARY INFORMATION IS BASED ON A FINAL SUBDIVISION PLAT MADE BY FRED KENDALL PRICE, L.S. DATED JULY 29, 2018 RECORDED IN INSTRUMENT NUMBER 190000228. 2.ANY UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE SURVEYOR MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. 3.HORIZONTAL ORIENTATION IS BASED ON VA. NAD 83 NORTH ZONE STATE GRID; VERTICAL DATUM IS BASED ON NAVD 88 ELEVATIONS ESTABLISHED USING GPS METHODS. ABBREVIATION DEFINITION DRAINAGE MANHOLE ELECTRIC CONTROL BOX FINISHED FLOOR ELEVATION FIRE HYDRANT GUY ANCHOR INVERT MAIL BOX MANHOLE METAL LIGHT POLE METAL POST POLYVINYLCHLORIDE PIPE REINFORCED CONCRETE PIPE SANITARY SEWER VALVE TELEPHONE RISER BOX WATER METER WOOD POWER POLE WOOD SIGN POST WATER VALVE MAPLE OAK BUILDING RESTRICTION LINE E U/G ELECTRIC LINE X X FENCE W U/G WATER LINE U/G SANITARY SEWER FORCE MAINFM TEST BORING RK&K, LLP 2100 E. CARY STREET, SUITE 309 RICHMOND, VIRGINIA 23223 ATTN:JEFFREY KAPINOS, P.E. PHONE: 804-782-1903 FAX: 804-782-2142 E-MAIL: JKapinos@rkk.com OWNER / DEVELOPER ENGINEER PARCEL # ADDRESS: ZONING: 115 CRAPPIE CT LAKE FREDERICK, VIRGINIA 22630 RURAL AGRICULTURAL (RA) FREDERICK WATER 315 TASKER RD STEPHENS CITY, VIRGINIA 22655 ATTN: MICHAEL NEWLIN, P.E. PHONE: (540)-868-9974 E-MAIL: MNewlin@frederickwater.com X YES NOUTILITIES COUNTY WATER COUNTY SEWER SPECIAL FLOOD HAZARD AREA INFORMATION SPECIAL FLOOD HAZARD AREA (FLOODPLAIN) YES NO X X FREDERICK WATER 315 TASKER ROAD STEPHENS CITY, VIRGINIA 22655 CONTACT: MICHAEL NEWLIN 540-868-1061 RAPPAHANNOCK ELECTRIC COOPERATIVE 247 INDUSTRIAL COURT FREDERICKSBURG, VIRGINIA 22408 CONTACT: ZACHARY HICKS 540-898-8500 INST. #: PROJECT AREA:0.57 AC 87B-1-1F NOVEMBER, 2023 GENERAL NOTES: 1.CONTRACTOR SHALL VERIFY FIELD CONDITIONS BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES. CONTRACTOR SHALL VERIFY EXISTING ELEVATIONS AND DIMENSIONS WHERE NEW WORK WILL MATCH EXISTING. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION PRIOR TO THE COMMENCEMENT OF WORK. 2.CONTRACTOR SHALL OBTAIN ALL THE NECESSARY PERMITS FROM THE APPROPRIATE AUTHORITIES, DEPARTMENTS, AND/OR AGENCIES HAVING JURISDICTION PRIOR TO COMMENCING WORK. 3.CONTRACTOR SHALL TAKE CARE TO AVOID DAMAGE TO EXISTING STRUCTURES, PIPING, ELECTRICAL EQUIPMENT, ETC. THAT ARE NOT INDICATED TO BE DEMOLISHED OR REMOVED. ANY DAMAGE TO EXISTING STRUCTURES AND UTILITIES NOT INDICATED TO BE DEMOLISHED OR REMOVED SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. 4.THE CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL DEBRIS GENERATED DURING THE PROJECT OFF SITE AT A PROPERLY PERMITTED DISPOSAL FACILITY. 5.THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL STORMWATER DRAINS FROM SEDIMENT, DEBRIS, TRASH, ETC. RESULTING FROM CONSTRUCTION ACTIVITY. 6.BUILDING SHALL COMPLY WITH THE 2018 VIRGINIA UNIFORM STATEWIDE BUILDING CODE. OTHER CODES THAT MAY APPLY ARE INTERNATIONAL FIRE CODE 2018, THE VIRGINIA PLUMBING CODE, AND THE NEC. APPROVALS FREDERICK COUNTY ZONING ADMINISTRATOR DATE INDEX OF DRAWINGS SHEET NO.SHEET DESIGNATION DESCRIPTION 01 G-01 COVER SHEET AND INDEX OF DRAWINGS 02 G-02 GENERAL NOTES 03 G-03 ABBREVIATIONS AND LEGEND 04 G-04 PLANT PROCESS FLOW DIAGRAM AND DESIGN CRITERIA 05 G-05 HYDRAULIC PROFILES 06 C-01 GENERAL NOTES AND DETAILS 07 C-02 EROSION AND SEDIMENT CONTROL NOTES AND DETAILS 08 C-03 EXISTING SITE CONDITIONS 09 C-04 EROSION AND SEDIMENT CONTROL PLAN 10 C-05 LAYOUT PLAN 11 C-06 UTILITY PLAN 12 C-07 GRADING PLAN 13 C-08 UTILITY PROFILES 14 C-09 PRE AND POST LAND COVER AREAS 15 C-10 STORMWATER COMPLIANCE 16 C-11 UTILITY DETAILS 17 A-01 LIFE SAFETY PLAN 18 A-02 FINISHED FLOOR PLAN AND DETAILS 19 S-01 STRUCTURAL GENERAL NOTES 20 S-02 DIRTY BACKWASH BASIN - PLAN AND SECTION 21 S-03 TREATMENT BUILDING - PLAN 22 S-04 TREATMENT BUILDING - SECTIONS 23 S-05 TREATMENT BUILDING - DETAILS 24 S-06 STANDARD DETAILS 25 PM-01 TREATMENT BUILDING PLAN 26 PM-02 TREATMENT BUILDING SECTIONS 27 PM-03 TREATMENT BUILDING SECTIONS 28 PM-04 TREATMENT BUILDING CHEMICAL ROOM PLAN AND SECTIONS 29 PM-05 TREATMENT BUILDING SECTIONS 30 PM-06 SECTIONS AND DETAILS 31 PM-07 DETAILS 32 PM-08 CHEMICAL FEED SCHEMATICS 33 PM-09 GROUND STORAGE TANK PLAN AND PROFILE DETAILS 34 PM-10 GROUND STORAGE TANK FOUNDATION AND PIPING DETAILS 35 PM-11 GROUND STORAGE TANK OVERFLOW AND LADDER DETAILS 36 PM-12 DIRTY BACKWASH BASIN AND VALVE VAULT - PLANS AND SECTIONS 37 M-01 PLUMBING PLAN AND SECTIONS 38 M-02 PLUMBING DETAILS 39 M-03 HVAC PLAN AND SECTIONS 40 M-04 HVAC DETAILS AND SCHEDULES 41 E-01 ELECTRICAL ABBREVIATIONS, SYMBOLS, AND NOTES 42 E-02 ELECTRICAL SITE PLAN 43 E-03 ELECTRICAL DUCT BANK SECTIONS AND CONDUIT SCHEDULE 44 E-04 WATER TREATMENT BUILDING LIGHTING AND RECEPTACLE PLAN 45 E-05 WATER TREATMENT BUILDING POWER PLAN 46 E-06 WATER TREATMENT BUILDING HVAC ELECTRICAL PLAN 47 E-07 PRESSURE FILTER WIRING DETAILS 48 E-08 DIRTY BACKWASH BASIN ELECTRICAL PLAN AND DETAILS 49 E-09 GROUND STORAGE TANK ELECTRICAL PLAN 50 E-10 MCC-LF ELEVATION 51 E-11 MCC-LF ONE-LINE DIAGRAM 52 E-12 MCC-LF CONTROL WIRING DIAGRAMS 53 E-13 MCC-LF CONTROL WIRING DIAGRAMS 53A ES-01 ELECTRICAL SITE LIGHTING PLAN 54 PCS-01 PCS ABBREVIATIONS, SYMBOLS, AND LEGEND 55 PCS-02 PLC SYSTEM ARCHITECTURE 56 PCS-03 WTF CONTROL PANEL 57 PCS-04 WTF CONTROL PANEL WIRING DIAGRAM 58 PCS-05 WTF CONTROL PANEL WIRING DIAGRAM 59 PCS-06 WTF CONTROL PANEL WIRING DIAGRAM 60 PCS-07 WTF CONTROL PANEL WIRING DIAGRAM OJGSNRSITESTONEWALL JACKSON HWYFRONT ROYAL PIKEFAI R F A X P I K E LORD FAIRFAX H W Y RO C K Y G L E N D R SIL E N T H I L L LN R A C H E L C A R S O N D R T U R N S T O N E L N TOW H E E D R LAKE FREDER ICKDR RAC HEL CA RS ON D R LAKE FREDERICK FEATHERBED RDASPHALT PAVEMENT RESPONSIBLE LAND DISTURBER: NAME: CERTIFICATION#: DATE: THE RESPONSIBLE LAND DISTURBER IS THAT PARTY RESPONSIBLE FOR CARRYING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. EDGE OF PAVEMENT PROPOSED FINISHED GRADE CONTOUR ELEVATION CLEAR COVER CENTERLINE ELEVATION TYPICAL EXISTING SITE FEATURESPROPOSED SITE FEATURES SITE PLAN #34-23 BUILDING RESTRICTION LINE:25' (SEE SHEET C-03) 1.FREDERICK COUNTY ZONING ADMINISTRATOR APPROVAL EXPIRES AT FIVE (5) YEARS FROM THE DATE OF SITE PLAN APPROVAL. 2.THE FREDERICK COUNTY DEPARTMENT OF INSPECTIONS APPROVAL DOES NOT CONSTITUTE A BUILDING PERMIT. BUILDING PLANS MUST BE SUBMITTED AND APPROVED PRIOR TO CONSTRUCTION ANY STRUCTURE. FURTHERMORE, THE SITE MUST BE APPROVED BY INSPECTIONS. TOTAL ACREAGE: 190000228 1.2383 ACRES DISTURBED ACREAGE: 0.57 ACRES FIRM PANEL: 51069C0350E EFFECTIVE DATE: JANUARY 29, 2021 Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTION „ ‚ ƒResponsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTION PLANT CAPACITYPROPOSED0.336 MGDSODIUM HYPOCHLORITE FOR OXIDATION AND DISINFECTION12.5 TRADE% LIQUID SOLUTION (125 G/L AS Cl2)NUMBER OF PROP. STORAGE TANKS1VOLUME OF PROP. STORAGE TANK (30 DAY SUPPLY)680 GALAPPLICATION POINT - RAW WATER:NUMBER OF OPERATING METERING PUMPS*1METERING PUMP CAPACITY0.0033-33.3 GAL/HRMAXIMUM DOSE6.82 MG/L as Cl2APPLICATION POINT - FILTER EFFLUENT/GST INFLUENT:NUMBER OF OPERATING METERING PUMPS*1METERING PUMP CAPACITY0.0005-7 GAL/HRMAXIMUM DOSE1.5 MG/L as Cl2*NOT INCLUDING SPAREFLUORIDE FOR ORAL HEALTH4% Sodium Fluoride Solution (Saturator)SATURATOR TANK1SOLUTION TANK1VOLUME OF PROP. TANKS (EACH)55 GALAPPLICATION POINT - FILTER EFFLUENT/GST INFLUENT:NUMBER OF OPERATING METERING PUMPS*1METERING PUMP CAPACITY3.17 GAL/HRMAXIMUM DOSE0.7 MG/L*NOT INCLUDING SPAREResponsive People | Creative Solutions Engineers | Construction Managers | Planners | Scientists www.rkk.com P: 804.782.1903 2100 E. Cary St. Suite 309 | Richmond, VA 23223 LAKE FREDERICK WATER TREATMENT FACILITY 02/17/2023100% SUBMITTAL NOT FOR CONSTR- UCTION LAKE FREDERICK PLANT PROCESS FLOW DIAGRAMNOT TO SCALEDESIGN CRITERIA Responsive People | Creative Solutions Engineers | Construction Managers | Planners | Scientists www.rkk.com P: 804.782.1903 2100 E. Cary St. Suite 309 | Richmond, VA 23223 LAKE FREDERICK WATER TREATMENT FACILITY 02/17/2023100% SUBMITTAL NOT FOR CONSTR- UCTION HYDRAULIC PROFILEWELL PUMP TO GROUND STORAGE TANKHYDRAULIC PROFILEGROUND STORAGE TANK TO LAKE FREDERICK ELEVATED STORAGE TANKNOTE: THIS HYDRAULIC GRADE LINE REPRESENTS THE OPTION TOREACH THE 890 FEET PRESSURE ZONE. Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTION’ ’ ’ ’ ⅝”¾”¾””” ” ’ ’ ’ ’’ Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTION3" MIN. 3" MIN. 12' MIN.* FILTER FABRIC b b UGEVKQP aÄa UGEVKQP bÄb * MUST EXTEND THE FULL WIDTH OF THE INGRESS AND EGRESS OPERATION 8DOT 1 COARSE AGGREGATE POSITI8E DRAINAGE TO SEDIMENT TRAPPING DE8ICE WASHRAC- ** OPTIONAL 12' MIN.*1' MIN. 1' MIN. 1' MIN. EXIST. PA8EMENT ' MIN. ** MUST EXSTEND THE FULL WIDTH OF THE INGRESS AND EGRESS OPERATION PLAN 8IEW a a EXIST. GROUND " MIN.FILTER FABRIC 13' ' MIN.8DOT 1 COARSE AGGREGATE EXIST. PA8EMENT MOUNTABLE BERM OPTIONAL SIDE ELE8ATION STONE CONSTRUCTION ENTRANCE STD. SPEC. 3.2 Ä 8A. EROSION AND SEDIMENT CONTROL HANDBOO- 12 ' MAX EMBED " OF FILTER CLOTH IN TRENCH TO ANCHOR BOTTOM OF CLOTH. COMPACT THOROUGHL; FLOW FLOW PRO8IDE 1" TUC- OR SUITABL; REINFORCED TOP END SECTION EMBED " OF FILTER CLOTH IN TRENCH TO ANCHOR BOTTOM OF CLOTH. COMPACT THOROUGHL; FLOW FLOW PRO8IDE 1" TUC- OR SUITABL; REINFORCED TOP END SECTION " FILTER FABRIC WIRE FENCING SILT FENCE STD. SPEC. 3. Ä 8A. EROSION AND SEDIMENT CONTROL HANDBOO- 12 WITH WIRE BAC-INGNO WIRE BAC-ING " "" * WIRE MESH SHALL BE A MINIMUM OF 1 GUAGE AND SHALL HA8E A MAXIMUM MESH SPACING OF ". VTGG RTQVGEVKQP STD. SPEC. 3.3 Ä 8A. EROSION AND SEDIMENT CONTROL HANDBOO- 12 -- ‐ - ‐ - - - ‐ - ‐- - - - - - - ‐ ‐ ‐- ‐ - ‐ ‐ - - -- ‐ -- - - ‐ -- -- - - -- W W W W W W W W W W W W W W WXXXXXXXXXXXXXXXXX XXXXXE E E E E E E E E E E E EE EXOHE OHE OHE PIN 87B-1-1-A(PARCEL A)FREDERICK-WINCHESTERSERVICE AUTHORITYINST. 0700095764.0174 ACRESPIN 87B-1-1-F(PARCEL F)FREDERICK WATERINST. 1900002281.2383 ACRESPIN 87B-1-1-B(PARCEL B1)SHENANDOAH HOMEOWNERSASSOCIATION, INC.INST. 080005826RACHEL CARSON DRIVE (PRIVATE)CR A P P I E C O U R T (PRI V A T E )S 78°42'58" E 700.00' (TOTAL)(150.44')S 13°5 7 ' 0 2 " W 3 4 7 . 7 6 ' N 2 3 ° 2 3 ' 4 0 " E 1 0 1 . 1 7 ' N 2 3 ° 4 4 ' 4 4 " E 31. 4 4 ' C1 C2 C3C4C5(142.60')PIN 87B-1-1-B(PARCEL B1)SHENANDOAH HOMEOWNERSASSOCIATION, INC.INST. 080005826SPIKE 9501N=7061144.043E=11579882.693ELEV.=578.97FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FMFMFMFMFMFMFMFMW W W W SPIKE 9502N=7061505.207E=11579956.557ELEV.=571.1625'S 78°42'58" E - 100.20' N 2 3 ° 2 3 ' 4 0 " E - 7 0 . 2 3 ' N 2 3 ° 4 4 ' 4 4 " E S 13°5 7 ' 0 2 " W - 2 9 9 . 8 2 'R= 1425'CH=113.23'CH. BRG= S 70° 08' 24" E31. 4 4 ' R= 119.0' CH=71.31' CH. BRG= N 0 6 ° 1 8 ' 3 9 " E R= 247.0' CH=146.5 7 ' CH. BRG= N 0 6 ° 0 8 ' 0 7 " E Responsive People | Creative Solutions Engineers | Construction Managers | Planners | Scientists www.rkk.com P: 804.782.1903 2100 E. Cary St. Suite 309 | Richmond, VA 23223 LAKE FREDERICK WATER TREATMENT FACILITY 02/17/2023100% SUBMITTAL NOT FOR CONSTR- UCTION EXISTING SITE CONDITIONS C-03 OJG SNR NOTES:1. THE INFORMATION SHOWN HEREON IS BASED ON AN ACTUAL FIELD SURVEY COMPLETEDSEPTEMBER 29, 2020. BOUNDARY INFORMATION IS BASED ON A FINAL SUBDIVISION PLAT MADEBY FRED KENDALL PRICE, L.S. DATED JULY 29, 2018 RECORDED IN INSTRUMENT NUMBER190000228.2. ANY UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEYINFORMATION AND EXISTING DRAWINGS. THE SURVEYOR MAKES NO GUARANTEES THAT THEUNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER INSERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THEUNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HEDOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATIONAVAILABLE.3. HORIZONTAL ORIENTATION IS BASED ON VA. NAD 83 NORTH ZONE STATE GRID; VERTICALDATUM IS BASED ON NAVD 88 ELEVATIONS ESTABLISHED USING GPS METHODS.ABBREVIATIONDEFINITIONDRAINAGE MANHOLEELECTRIC CONTROL BOXFINISHED FLOOR ELEVATIONFIRE HYDRANTGUY ANCHORINVERTMAIL BOXMANHOLEMETAL LIGHT POLEMETAL POSTPOLYVINYLCHLORIDE PIPEREINFORCED CONCRETE PIPESANITARY SEWER VALVETELEPHONE RISER BOXWATER METERWOOD POWER POLEWOOD SIGN POSTWATER VALVEMAPLEOAKCURVERADIUSARC LENGTHCHORD LENGTHCHORD BEARINGDELTA ANGLETANGENTC1222.00'133.75'131.73'N 06°08'07" E34°31'06"68.97'C2144.00'87.64'86.29'N 06°18'39" E34°52'10"45.22'C325.00'38.57'34.86'N 67°56'29" E88°23'29"24.31'C41400.00'111.67'111.64'S 70°08'53" E04°34'12"55.86'C5300.00'18.94'18.93'S 74°14'28" E03°37'00"9.47'BUILDING RESTRICTION LINELEGENDCURVE TABLETOPOGRAPHIC SURVEYOF THE LANDS OFFREDERICK WATER[PIN 87B-1-1-F] INSTRUMENT NUMBER 190000228ANDFREDERICK -WINCHESTER SERVICE AUTHORITY[PIN 87B-1-1-A] INSTRUMENT NUMBER 070009576OPEQUON MAGISTERIAL DISTRICTFREDERICK COUNTY, VIRGINIAEU/G ELECTRIC LINEXXFENCEWU/G WATER LINEU/G SANITARY SEWER FORCE MAINFMTEST BORING1"=20' W W W W W W W W W W W W W W WXXXXXX XXE E E E E E E E E E E E EE EXOHEOHEOHE RACHEL CARSON DRIVE (PRIVATE)CRAPPIE COURT(PRIVATE)(150.44')S 13°5 7 ' 0 2 " W 3 4 7 . 7 6 ' N 23°23'40" E 101.17'N 23°44'44" E31.44'C1 C2 C3C4C5(142.60')FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM FMFMFMFMFMFMFMW W WTP SFCEW W W W W W W W W W W W W W WXXX XXXXXE E E E E E E E E E E E EE EXOHE OHE OHE RACHEL CARSON DRIVE (PRIVATE)CR A P P I E C O U R T (PRI V A T E )(150.44')S 13°5 7 ' 0 2 " W 3 4 7 . 7 6 ' N 2 3 ° 2 3 ' 4 0 " E 1 0 1 . 1 7 ' N 2 3 ° 4 4 ' 4 4 " E 31. 4 4 ' C1 C2 C3C4C5(142.60')FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FMFMFMFMFMFMFMW W W SFCEResponsive People | Creative Solutions Engineers | Construction Managers | Planners | Scientists www.rkk.com P: 804.782.1903 2100 E. Cary St. Suite 309 | Richmond, VA 23223 LAKE FREDERICK WATER TREATMENT FACILITY 02/17/2023100% SUBMITTAL NOT FOR CONSTR- UCTION EROSION AND SEDIMENT CONTROL PLAN C-04 1"=20'OJG SNR TREE PROTECTION3.38EROSION AND SEDIMENT CONTROL NARRATIVE:1.THE OWNER, OR THE OWNER'S REPRESENTATIVES, MUST FIRSTOBTAIN A LAND DISTURBANCE PERMIT FROM FREDERICK COUNTYPRIOR TO COMMENCEMENT OF ANY LAND DISTURBING ACTIVITIES.2.A PRE-CONSTRUCTION MEETING WITH THE FREDERICK COUNTYE&S INSPECTOR MUST OCCUR PRIOR TO ANY LAND DISTURBANCEON THE SITE. FREDERICK COUNTY REQUIRES MANDATORYNOTIFICATION 48 HOURS PRIOR TO THE COMMENCEMENT OF LANDDISTURBING ACTIVITY, AND PRIOR TO THE FINAL INSPECTION.CONTACT FREDERICK COUNTY.3.INSTALL OVERALL TREE PROTECTION TAPE ALONG CLEARINGLIMITS AS SHOWN ON THE PLAN. USE THIS TO DEFINE ADJOININGPROPERTY LIMITS.4.CLEAR AS NEEDED TO INSTALL TEMPORARY WIRE BACK SILTFENCE AND STABILIZE.5.ALL THE CONSTRUCTION VEHICLES LEAVING THE SITE SHALL BECLEANED OF LOOSE DIRT. NO TRACKING OF DIRT ONTO CRAPPIECT AND RACHEL CARSON DRIVE IS ALLOWED. ANY DIRT TRACKEDOFF THE SITE MUST BE IMMEDIATELY SWEPT/SHOVELED UP &RETURNED TO THE SITE.6.ONCE SILT FENCE AND CONSTRUCTION ENTRANCE ARE INSTALLEDAND APPROVED BY THE FREDERICK COUNTY E&S INSPECTORCLEARING AND GRUBBING MAY COMMENCE.7.PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BEAPPLIED TO DENUDED AREAS WITHIN 7 DAYS AFTER FINAL GRADEIS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOILSTABILIZATION SHALL BE APPLIED WITH 7 DAYS TO DENUDEDAREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAINDORMANT (UNDISTURBED) FOR LONGER THAN 14 DAYS.PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS THATARE TO BE LEFT DORMANT FOR MORE THAN ONE (1) YEAR.8.CONTRACTOR SHALL MAINTAIN POSITIVE FLOW INTO THE SILTFENCE AS GRADING COMMENCES. FILL SLOPES SHALL BECONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION PERMS-7.9.ALL E&S MEASURES SHALL BE INSTALLED AND MAINTAINED PERLATEST EDITION OF THE VIRGINIA EROSION AND SEDIMENTCONTROL MANUAL.10.NO EROSION AND SEDIMENT CONTROL MEASURES CAN BEREMOVED WITHOUT APPROVAL OF THE E&S INSPECTOR FOR THEPROJECT.TEMPORARY SEEDINGPERMANENT SEEDING3.313.32FOR CONSTRUCTION DETAILS AND SPECIFICATIONS REFER TO THE"VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK" THIRD EDITION,1992.XXLODCONSTRUCTIONENTRANCESILT FENCELIMITS OF DISTURBANCE3.023.05CLEARING LIMTISEROSION CONTROL LEGEND:INITIAL EROSION AND SEDIMENT CONTROL PLANFINAL EROSION AND SEDIMENT CONTROL PLAN W W W W W W W W W W W W W W WXXXXXXXXXXXXXXXXX XXXXXXOHE OHE OHE PIN 87B-1-1-A(PARCEL A)FREDERICK-WINCHESTERSERVICE AUTHORITYINST. 0700095764.0174 ACRESPIN 87B-1-1-F(PARCEL F)FREDERICK WATERINST. 1900002281.2383 ACRESPIN 87B-1-1-B(PARCEL B1)SHENANDOAH HOMEOWNERSASSOCIATION, INC.INST. 080005826RACHEL CARSON DRIVE (PRIVATE)CR A P P I E C O U R T (PRI V A T E )S 78°42'58" E 700.00' (TOTAL)(150.44')S 13°5 7 ' 0 2 " W 3 4 7 . 7 6 ' N 2 3 ° 2 3 ' 4 0 " E 1 0 1 . 1 7 ' N 2 3 ° 4 4 ' 4 4 " E 31. 4 4 ' C1 C2 C3C4C5(142.60')PIN 87B-1-1-B(PARCEL B1)SHENANDOAH HOMEOWNERSASSOCIATION, INC.INST. 080005826SPIKE 9501N=7061144.043E=11579882.693ELEV.=578.97W W W W SPIKE 9502N=7061505.207E=11579956.557ELEV.=571.16Responsive People | Creative Solutions Engineers | Construction Managers | Planners | Scientists www.rkk.com P: 804.782.1903 2100 E. Cary St. Suite 309 | Richmond, VA 23223 LAKE FREDERICK WATER TREATMENT FACILITY 02/17/2023100% SUBMITTAL NOT FOR CONSTR- UCTION LAYOUT PLAN C-05 1"=20'OJG SNR ASPHALT PAVEMENTSIDEWALK (ABUTTING STRUCTURES) DETAILBOLLARD DETAILNOTE:1. UPON COMPLETION OF PAVING, PROVIDE STRIPING TO PREVENT VEHICLEPARKING IN ACCORDANCE WITH FIRE MARSHAL REQUIREMENTS IN THESE AREAS.SEE FIRE LANE PARKING SIGN AND PAVEMENT MARKINGS ON THIS SHEET. W W W W W W W W W W W W W W WXXXXXXXXXXXXXXXXX XXXXXE E E E E E E E E E E E EE EXOHE OHE OHE PIN 87B-1-1-A(PARCEL A)FREDERICK-WINCHESTERSERVICE AUTHORITYINST. 0700095764.0174 ACRESPIN 87B-1-1-F(PARCEL F)FREDERICK WATERINST. 1900002281.2383 ACRESPIN 87B-1-1-B(PARCEL B1)SHENANDOAH HOMEOWNERSASSOCIATION, INC.INST. 080005826RACHEL CARSON DRIVE (PRIVATE)CR A P P I E C O U R T (PRI V A T E )S 78°42'58" E 700.00' (TOTAL)(150.44')S 13°5 7 ' 0 2 " W 3 4 7 . 7 6 ' N 2 3 ° 2 3 ' 4 0 " E 1 0 1 . 1 7 ' N 2 3 ° 4 4 ' 4 4 " E 31. 4 4 ' C1 C2 C3C4C5(142.60')PIN 87B-1-1-B(PARCEL B1)SHENANDOAH HOMEOWNERSASSOCIATION, INC.INST. 080005826SPIKE 9501N=7061144.043E=11579882.693ELEV.=578.97FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FMFMFMFMFMFMFMFMW W W W SPIKE 9502N=7061505.207E=11579956.557ELEV.=571.16FDCSEENOTE 2.DED. F.H.E E E E E E FM FM FM FM Responsive People | Creative Solutions Engineers | Construction Managers | Planners | Scientists www.rkk.com P: 804.782.1903 2100 E. Cary St. Suite 309 | Richmond, VA 23223 LAKE FREDERICK WATER TREATMENT FACILITY 02/17/2023100% SUBMITTAL NOT FOR CONSTR- UCTION UTILITY PLAN C-06 OJG SNR AS SHOWNINSET 'A'SCALE: 1"=5'INSET 'B'SCALE: 1"=5'NOTE:1.SEE SHEET C-11 FOR RESTRAINT DETAILS.2.FDC SHALL BE CONNECTED TO THE 4-INCH DI FIRE LINERISER IN BUILDING. FDC SHALL BE INSTALLED PERVIRGINIA CONSTRUCTION CODE AND VIRGINIASTATEWIDE FIRE PREVENT CODE, LATEST EDITION.3.AREA AROUND FDC AND FIRE HYDRANT SHALL BE KEPTCLEAR OF ANY OBSTRUCTIONS. W W W W W W W W W W W W W W WXXXXXXXXXXXXXXXXX XXXXXE E E E E E E E E E E E EE EXOHE OHE OHE PIN 87B-1-1-A(PARCEL A)FREDERICK-WINCHESTERSERVICE AUTHORITYINST. 0700095764.0174 ACRESPIN 87B-1-1-F(PARCEL F)FREDERICK WATERINST. 1900002281.2383 ACRESPIN 87B-1-1-B(PARCEL B1)SHENANDOAH HOMEOWNERSASSOCIATION, INC.INST. 080005826RACHEL CARSON DRIVE (PRIVATE)CR A P P I E C O U R T (PRI V A T E )S 78°42'58" E 700.00' (TOTAL)(150.44')S 13°5 7 ' 0 2 " W 3 4 7 . 7 6 ' N 2 3 ° 2 3 ' 4 0 " E 1 0 1 . 1 7 ' N 2 3 ° 4 4 ' 4 4 " E 31. 4 4 ' C1 C2 C3C4C5(142.60')PIN 87B-1-1-B(PARCEL B1)SHENANDOAH HOMEOWNERSASSOCIATION, INC.INST. 080005826SPIKE 9501N=7061144.043E=11579882.693ELEV.=578.97FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FMFMFMFMFMFMFMFMW W W W SPIKE 9502N=7061505.207E=11579956.557ELEV.=571.16Responsive People | Creative Solutions Engineers | Construction Managers | Planners | Scientists www.rkk.com P: 804.782.1903 2100 E. Cary St. Suite 309 | Richmond, VA 23223 LAKE FREDERICK WATER TREATMENT FACILITY 02/17/2023100% SUBMITTAL NOT FOR CONSTR- UCTION GRADING PLAN C-07 OJG SNR 1"=20'SETTLEMENT PLATFORMSCHEDULENO.NORTHINGEASTINGSP-017061272.093311579981.8100SP-027061226.627811579969.1382 6'' DI RAW WATER LINE5505555605655705755805855505555605655705755805856'' DI GST EFFLUENT- HSP INFLUENT WATER LINE555560565570575580585555560565570575580585FILTERED WATER - 6'' DI GST INFLUENT WATER LINE5555605655705755805855555605655705755805856'' DI HSP DISCHARGE LINE5605655705755805855605655705755805854'' DI DRAIN FROM GST5595605655705755805855905595605655705755805855908'' DI DIRTY BACKWASH DISCHARGE LINE5555605655705755805855555605655705755805852.5'' PVC DIRTY BACKWASH BASIN DISCHARGE5555605655705755805855555605655705755805854'' DI FIRE LINE5605655705755805855905605655705755805855904'' DI DRAIN LINE560565570575580585560565570575580585Responsive People | Creative Solutions Engineers | Construction Managers | Planners | Scientists www.rkk.com P: 804.782.1903 2100 E. Cary St. Suite 309 | Richmond, VA 23223 LAKE FREDERICK WATER TREATMENT FACILITY 02/17/2023100% SUBMITTAL NOT FOR CONSTR- UCTION UTILITY PROFILES C-08 H=1":20' V=1":5' OJG SNRPROPOSED GRADEEXISTING GRADEFILL SECTIONSNOTE:1.SEE SHEET C-11 FOR RESTRAINT DETAILS. W W W W W W W W W W W W W W WXXXXEEEEEEEEEEE E EE EXOHEOHERACHEL CARSON DRIVE (PRIVATE)CRAPPIE COURT(PRIVATE)C1 C2 C3C4C5FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM FMFMFMFMFMFMW W WSPIKE 9502N=7061505.207E=11579956.557ELEV.=571.16PIN 87B-1-1-B(PARCEL B1)SHENANDOAH HOMEOWNERSASSOCIATION, INC.INST. 080005826PIN 87B-1-1-B(PARCEL B1)SHENANDOAH HOMEOWNERSASSOCIATION, INC.INST. 080005826PIN 87B-1-1-A(PARCEL A)FREDERICK-WINCHESTERSERVICE AUTHORITYINST. 0700095764.0174 ACRESPIN 87B-1-1-F(PARCEL F)FREDERICK WATERINST. 1900002281.2383 ACRESW W W W W W W W W W W W W W WXXXX E E E E E E E E E E E E EE EXOHE OHE RACHEL CARSON DRIVE (PRIVATE)CR A P P I E C O U R T (PRI V A T E ) C1 C2 C3C4C5FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FMFMFMFMFMFMW W W SPIKE 9502N=7061505.207E=11579956.557ELEV.=571.16PIN 87B-1-1-B(PARCEL B1)SHENANDOAH HOMEOWNERSASSOCIATION, INC.INST. 080005826PIN 87B-1-1-B(PARCEL B1)SHENANDOAH HOMEOWNERSASSOCIATION, INC.INST. 080005826PIN 87B-1-1-A(PARCEL A)FREDERICK-WINCHESTERSERVICE AUTHORITYINST. 0700095764.0174 ACRESPIN 87B-1-1-F(PARCEL F)FREDERICK WATERINST. 1900002281.2383 ACRESResponsive People | Creative Solutions Engineers | Construction Managers | Planners | Scientists www.rkk.com P: 804.782.1903 2100 E. Cary St. Suite 309 | Richmond, VA 23223 LAKE FREDERICK WATER TREATMENT FACILITY 02/17/2023100% SUBMITTAL NOT FOR CONSTR- UCTION PRE AND POST LAND COVER AREAS C-09 OJG SNR 1"=20'PRE LAND COVER MAPPOST LAND COVER MAP Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTION Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTIONFINISHED WATER FLOW METER VAULT DN N A D '83 50' - 0"30' - 0"FE FE E E BAGGED GRANULAR SODIUM FLUORIDE STORAGE/ CONTAINMENT SODIUM HYPOCHLORITE STORAGE AND FEED ROOM 12'-8" AFF FE FE EXIT PATH OF TRAVEL APPROX 27' EXIT PATH OF TRAVEL APPROX 27' E.S. SODIUM HYPOCHLORITE FEED PUMPS SKID MAIN SODIUM HYPOCHLORITE STORAGE TANK INTERIOR INSULATED WALL E.S. 15' - 8" 8" CMU WALL (1 HOUR RATED PER UL U905) LAKE FREDERICK NEW WATER TREATMENT FACILITY BUILDING 120 CRAPPIE COURT LAKE FREDERICK, VA 22630 Description of Use: New Water Treatment Facility The Lake Frederick New Water Treatment Facility Building will contain new process equipment (pressure filtration system) and two chemical systems, as listed below, to produce potable water for use in Frederick Water’s distribution system. The building will contain a small laboratory area, electrical panels, and two control areas as detailed below. The building will have two Control Areas, adhering to Section 414.2. One that will house the Sodium Hypochlorite system as detailed below. The second larger area will house the Granular Sodium Fluoride for use in the fluoride saturation system will be stored in the open as detailed below. A brief outline of the anticipated quantities and process of these systems is listed below: Sodium Hypochlorite solution (12-15%) will be stored in an enclosed, ventilated, and temperature controlled room in the northwest corner of the proposed treatment building.Spill containment will be provided.A 30-day supply, as required by VDH, of sodium hypochlorite (NaOCl) solution (30 days = 650 gallons at this plant) will be stored in the tank.Tank size is 850 gallons as it is the next available volume after 550 gallons. Granular Sodium Fluoride will be stored in 50 pound bags (protected from moisture) for use with the fluoride saturation system (a dual tank, each ~55 gallons, integrated skid with containment) that is proposed to be located at the southwest corner of the building.It is proposed to specify whatever type of exhaust (overhead/wall mount, other) is necessary to filter and discharge dust (from system sodium fluoride refill) through the roof.Granular sodium fluoride will be added to the first of two tanks along with water.The solution formed is 4% sodium fluoride.The second tank will hold only the 4% sodium fluoride solution; feed tanks will pump from the second tank.The second tank helps to minimize solids clogging issues.Calculations indicate that a total of approximately 17 –50 pound bags will be required to provide six (6) months of fluoridation to the treated water. Construction Type: IIB Building Area: 1500 gsf Building Height: Wall height 14 feet; total height to roof apex is 15 feet Primary Applicable Codes: Virginia Construction Code / 2018 International Building Code / 2018 (By Reference) International Fire Code/ 2018 International Mechanical Code/ 2018 CODE SUMMARY CODE REFERENCE:SUMMARY NOTES Chapter 3 Use and Occupancy 307.6 High-hazard Group H-4 Fully Sprinklered Table 307.1(2) Max. Allow Quantity Per Control Area of Hazardous Material posing a Health Hazard = 500 gallons (with sprinkler = increase by 100% = 1000 gallons) Corrosive in a Closed System with sprinkler system in Control Room= 1000 gallons max (850 gallons Actual) Chapter 4 Special Detailed Occupancies Based on Use And Occupancy Section 414 Hazardous Materials; Providing Control Area for Sodium Hypochlorite Solution per 414.2 Chapter 5 General Building Heights and Areas H-4 Type II B Sprinklered Allow Height = 75’Actual Height = 15’ Allow # Stories = 4 Actual # Stories = 1 Allow Area = 23,000 SF Actual Area = 1500 SF Interior walls to meet criteria as listed in Section 603 Chapter 6 Types of Construction Table 601: Type IIB Construction: All building elements: 0 hour rated Chapter 10 Means of Egress Table 1004.1.2 Max Floor Area Allow per Occupant: Industrial areas = 100 sf/ occupant = 12 occupants max 1006.2 Egress from spaces: only one Exit Doorway required; 2 exit doorways provided Section 603 Combustible Material in Types I and II Construction Two control areas in the building divided by a 1 hour fire resistance rated wall per Table 414.2.2 FE FIRE EXTINGUISHER E EXIT E.S.EMERGENCY EYEWASH/SHOWER 1 HOUR RATED WALL LEGEND P: 804.782.1903LAKE FREDERICKWATER TREATMENT FACILITYSHEET2100 E. Cary St. Suite 309 | Richmond, VA 23223Engineers | Construction Managers | Planners | Scientistswww.rkk.comResponsive People | Creative SolutionsFREDERICK COUNTY, VIRGINIA - OPEQUON DISTRICTPLAN REVISIONS --SCALEAS SHOWNDATE:ENGINEER:CHECKED:CAD:JOB #: 19142.002SUBMITTALNOT FORCONSTR-UCTION100%11/15/2023 12:25:56 PM\\ad.rkk.com\fs\Cloud\Projects\2019\19124_FredWater\19124.002-Lake Frederick WTP Design\CADD\Revit\Option3A - Arch 2020.rvtDWAJSJK02/17/2023A-01LIFE SAFETY PLANSCALE: 3/8" = 1'-0" LIFE SAFETY PLAN NOTE: 1. FINAL LIFE SAFETY DESIGN INCLUDING EXTERIOR AND INTERIOR CONSTRUCTION AND FINISHES TO BE VERIFIED BY BUILDING MANUFACTURER AND SUBMITTED IN SIGNED AND SEALED SHOP DRAWINGS TO AUTHORITY HAVING JURISDICTION FOR FINAL APPROVAL. MOBILE WORKBENCH 48"x30" (BY GLOBAL INDUSTRIAL ITEM #T9F183149A OR APPROVED EQUAL) N A D '83 1 3 4 2 5 8" CMU WALL (1 HOUR RATED PER UL U905)2' - 0"2' - 6"2' - 0"2' - 0"2' - 0" A-021 2 50' - 0"30' - 0"3' - 4"3' - 1"12' - 0"2' - 3"2' - 5"8' - 0"7' - 0"3' - 4"9' - 3"15' - 8"3' - 4"1' - 2"14' - 0"NOTCH FOR VERTICAL VENT PIPE FINISHED FLOOR 574.25' 30" BASE SINK BASE DRAWERS 24"24"24" PROVIDE CORNER BLIND CABINET FINISHED FLOOR 574.25' UNDER COUNTER REF. BY OTHERS (PROVIDE END PANEL) 24" BASE 24" 24" PROVIDE CORNER BLIND CABINET P: 804.782.1903LAKE FREDERICKWATER TREATMENT FACILITYSHEET2100 E. Cary St. Suite 309 | Richmond, VA 23223Engineers | Construction Managers | Planners | Scientistswww.rkk.comResponsive People | Creative SolutionsFREDERICK COUNTY, VIRGINIA - OPEQUON DISTRICTPLAN REVISIONS --SCALEAS SHOWNDATE:ENGINEER:CHECKED:CAD:JOB #: 19142.002SUBMITTALNOT FORCONSTR-UCTION100%11/15/2023 12:26:04 PM\\ad.rkk.com\fs\Cloud\Projects\2019\19124_FredWater\19124.002-Lake Frederick WTP Design\CADD\Revit\Option3A - Arch 2020.rvtDWAJSJK02/17/2023A-02FINISHED FLOOR PLAN AND DETAILSSCALE: 3/8" = 1'-0" FINISHED FLOOR PLAN SCALE: 3/8" = 1'-0"A-02 1 CASEWORK -NORTH SCALE: 3/8" = 1'-0"A-02 2 CASEWORK -WEST NOTES: 1. THIS DRAWING IS INDICATION INTERIOR WALLS, DOOR OPENINGS, CASEWORK ONLY. BUILDING SHELL IS A PRE-ENGINEERED PRE-CAST CONCRETE BUILDING AND IS ENGINEERED AND DESIGNED BY BUILDING MANUFACTURER. FINAL DESIGN SHALL BE SUBMITTED PER SIGNED AND SEALED SHOP DRAWINGS FROM BUILDING MANUFACTURER. SEE SPECIFICATION 13120 FOR ADDITIONAL REQUIREMENTS. 2. DO NOT SCALE DRAWINGS. 3. SEE PM SHEETS FOR ADDITIONAL INFORMATION. DOOR SCHEDULE DOOR NO. DOOR FRAME HARDWARE FIRE RATING REMARKSWIDTH HEIGHT THICKNESS MATERIAL MATERIAL 1 3'-0" 7'-0" 1-3/4" FRP FRP HW-3 2 3'-0" 7'-0" 1-3/4" FRP FRP HW-3 3 3'-0" 7'-0" 1-3/4" FRP FRP HW-3 45 MINUTES 4 8'-0" 12'-0" ALUMINUM - HW-1 OVERHEAD ROLLING DOOR 5 12'-0" 12'-0" ALUMINUM - HW-1 OVERHEAD ROLLING DOOR Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTIONSTRUCTURAL GENERAL NOTESS-01AS NOTED_________” “” Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTIONDIRTY BACKWASH BASIN -PLAN AND SECTIONS-02AS NOTED_________DIRTY BACKWASH BASIN - PLAN 1 S-03 SECTION 1 SECTION 3 - BEAM B-1 SECTION AT HATCH SECTION 4 - SLAB SECTION AT HATCH SECTION 2 3 S-03 4 S-03 2 S-03 Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTIONTREATMENT BUILDING - PLANS-03AS NOTED_________2 S-06 1 S-06 TREATMENT BUILDING - PLAN 3 S-06 4 S-06 5 S-06 Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTIONTREATMENT BUILDING - SECTIONSS-04AS NOTED_________SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 MASONRY WALL DETAIL TYPICAL FLOOR SLAB RECESS DETAIL TYPICAL LINTEL DETAIL TYPICAL CMU CORNER REINFORCING DETAIL TYPICAL LADDER REINFORCING SPLICE DETAIL Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTIONTREATMENT BUILDING - DETAILSS-05N.T.S._________ Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTIONSTANDARD DETAILSS-06AS NOTED_________TYPICAL MASONRY WALL OPENING DETAIL CORNER REINFORCING DETAIL TYPICAL ADDITIONAL REINFORCING BAR DETAILS EQUIPMENT PAD DETAIL CONSTRUCTION JOINT SEALANT DETAIL SLAB EXPANSION JOINT DETAIL 1 PM-02 1 PM-03 1 PM-04 1 PM-05 HIGH SERVICE PUMP (TYP OF 2) FLUORIDE SATURATION AND FEED SKID WATER SOFTENER PM-04 1A 2 PM-03 2 PM-04 3 PM-04 SODIUM HYPOCHLORITE STORAGE AND FEED ROOM N A D '83 BAGGED GRANULAR SODIUM FLUORIDE STORAGE 6"ø, INF 6"ø, RW 8' - 3"6' - 0" 4' - 9"5' - 2"MOBILE WORK BENCH 3' - 10 1/2" FILTER CONTROL PANEL 1 PM-06FILL STATION AND DRIP BASIN, SEE DETAIL CHEMICAL VENT, SEE DETAIL 55 GALLON OVERFLOW DRUM 11" 2' - 6"3' - 9"1' - 2"1' - 5"1' - 3"5' - 8"9" 6' - 8 1/2"1' - 7 1/2"3 1/2"1' - 10"32 1 5 4 (BELOW) 6" ARV P: 804.782.1903LAKE FREDERICKWATER TREATMENT FACILITYSHEET2100 E. Cary St. Suite 309 | Richmond, VA 23223Engineers | Construction Managers | Planners | Scientistswww.rkk.comResponsive People | Creative SolutionsFREDERICK COUNTY, VIRGINIA - OPEQUON DISTRICTPLAN REVISIONS --SCALEAS SHOWNDATE:ENGINEER:CHECKED:CAD:JOB #: 19142.002SUBMITTALNOT FORCONSTR-UCTION100%11/15/2023 12:24:07 PM\\ad.rkk.com\fs\Cloud\Projects\2019\19124_FredWater\19124.002-Lake Frederick WTP Design\CADD\Revit\Option 3A - Mech 2020.rvtDTAJSJK02/17/2023PM-01TREATMENT BUILDING PLANSCALE: 1/2" = 1'-0" FINISHED FLOOR 4'2'1'0 6" SCALE: 1/2" = 1'-0" GRAPHICS SCALE: WATER SAMPLE TAP LOCATIONS NO. DESCRIPTION 1 RAW WATER SAMPLE TAP 2 POST OXIDANT INJECTION WATER SAMPLE TAP 3 POST FILTRATION WATER SAMPLE TAP 4 POST SECONDARY DISSINFECTION INJECTION WATER SAMPLE TAP 5 FINISHED WATER SAMPLE TAP NOTE: 1. ALL SAMPLE TAPS TO BE SMOOTH NOSED HOSE BIBBS. EMERGENCY EYEWASH/ SHOWER 6" RAW WATER INFLUENT CL EL 582.19' CL EL 578.69' CL EL 577.67' CL EL 576.17' FF EL 572.50' PM-07 6 PM-07 2 PM-06 2 6" 9" PRESSURE FILTER (BY OTHERS) 4' - 9" 11' - 5" PM-07 4 PM-07 7 3 4 2 6" ARV P: 804.782.1903LAKE FREDERICKWATER TREATMENT FACILITYSHEET2100 E. Cary St. Suite 309 | Richmond, VA 23223Engineers | Construction Managers | Planners | Scientistswww.rkk.comResponsive People | Creative SolutionsFREDERICK COUNTY, VIRGINIA - OPEQUON DISTRICTPLAN REVISIONS --SCALEAS SHOWNDATE:ENGINEER:CHECKED:CAD:JOB #: 19142.002SUBMITTALNOT FORCONSTR-UCTION100%11/15/2023 12:24:10 PM\\ad.rkk.com\fs\Cloud\Projects\2019\19124_FredWater\19124.002-Lake Frederick WTP Design\CADD\Revit\Option 3A - Mech 2020.rvtDTAJSJK02/17/2023PM-02TREATMENT BUILDING SECTIONSSECTION SCALE: 1/2" = 1'-0"PM-01 1 4'2'1'0 6" SCALE: 1/2" = 1'-0" GRAPHICS SCALE: WATER SAMPLE TAP LOCATIONS NO. DESCRIPTION 1 RAW WATER SAMPLE TAP 2 POST OXIDANT INJECTION WATER SAMPLE TAP 3 POST FILTRATION WATER SAMPLE TAP 4 POST SECONDARY DISSINFECTION INJECTION WATER SAMPLE TAP 5 FINISHED WATER SAMPLE TAP WATER SOFTENER TANK (TYP OF 2) BRINE TANK HIGH SERVICE PUMP (BEHIND FILTER CONTROL PANEL, TYP OF 2) FF EL 574.25'6' - 10"BAGGED GRANULAR SODIUM FLUORIDE STORAGE MOBILE WORK BENCH FLUORIDE SATURATION SKID 5 BRINE TANK WATER SOFTENER TANK FLUORIDE SATURATION SKID BAGGED GRANULAR SODIUM FLUORIDE STORAGE FF EL 574.25'8' - 6"1' - 10"P: 804.782.1903LAKE FREDERICKWATER TREATMENT FACILITYSHEET2100 E. Cary St. Suite 309 | Richmond, VA 23223Engineers | Construction Managers | Planners | Scientistswww.rkk.comResponsive People | Creative SolutionsFREDERICK COUNTY, VIRGINIA - OPEQUON DISTRICTPLAN REVISIONS --SCALEAS SHOWNDATE:ENGINEER:CHECKED:CAD:JOB #: 19142.002SUBMITTALNOT FORCONSTR-UCTION100%11/15/2023 12:24:12 PM\\ad.rkk.com\fs\Cloud\Projects\2019\19124_FredWater\19124.002-Lake Frederick WTP Design\CADD\Revit\Option 3A - Mech 2020.rvtDTAJSJK02/17/2023PM-03TREATMENT BUILDING SECTIONSSECTION SCALE: 1/2" = 1'-0"PM-01 1 SECTION SCALE: 3/4" = 1'-0"PM-01 2 4'2'1'0 6" SCALE: 1/2" = 1'-0" GRAPHICS SCALE: 3'2'1'0 6" SCALE: 3/4" = 1'-0" GRAPHICS SCALE:WATER SAMPLE TAP LOCATIONS NO. DESCRIPTION 1 RAW WATER SAMPLE TAP 2 POST OXIDANT INJECTION WATER SAMPLE TAP 3 POST FILTRATION WATER SAMPLE TAP 4 POST SECONDARY DISSINFECTION INJECTION WATER SAMPLE TAP 5 FINISHED WATER SAMPLE TAP 1 PM-02 1 PM-04 1 PM-05 BURIED 6" RAW WATER INFLUENT OPENING 6" CONC PAD 6" BFV EMERGENCY EYEWASH/ SHOWER 2 PM-04 3 PM-04 DUAL PUMP CHEMICAL FEED SKID SYSTEM 55 GAL DRUM N A D '8 3 4' - 0"1' - 2"1' - 5" 8' - 0"1' - 11"850 GALLON TANK 1' - 3"ARV AT HIGH POINT 2" TANK FILL 4" TANK VENT 1 FF EL 572.50' FF EL 574.25' PM-07 1 2' - 0"6" 6"9' - 7 1/2" CL EL 585.65' CL EL 586.65' PM-06 2 9" CL EL 585.25' 850 GALLON TANK FF EL 572.50' FF EL 574.25' CAPPED FOR FUTURE FILL CONNECTION 55 GALLON OVERFLOW DRUM CL EL 587.25' CL EL 586.65' TANK VENT TANK FILL TANK OVERFLOW 55 GALLON DRUM 6" RAW WATER INFLUENT CHEMICAL FEED SYSTEM SKID 850 GALLON TANK CL EL 585.25' FF EL 574.25' FF EL 572.50' 4' - 7" 9"4' - 1 1/2"6' - 6" 7 1/2" CL EL 585.65' CL EL 587.25' CL EL 586.65' CL EL 580.67' EMERGENCY SHOWER/ EYEWASH FLOW METER TANK OVERFLOW TANK VENT TANK FILL PM-07 5 1 P: 804.782.1903LAKE FREDERICKWATER TREATMENT FACILITYSHEET2100 E. Cary St. Suite 309 | Richmond, VA 23223Engineers | Construction Managers | Planners | Scientistswww.rkk.comResponsive People | Creative SolutionsFREDERICK COUNTY, VIRGINIA - OPEQUON DISTRICTPLAN REVISIONS --SCALEAS SHOWNDATE:ENGINEER:CHECKED:CAD:JOB #: 19142.002SUBMITTALNOT FORCONSTR-UCTION100%11/15/2023 12:24:15 PM\\ad.rkk.com\fs\Cloud\Projects\2019\19124_FredWater\19124.002-Lake Frederick WTP Design\CADD\Revit\Option 3A - Mech 2020.rvtDTAJSJK02/17/2023PM-04TREATMENT BUILDING CHEMICAL ROOMPLAN AND SECTIONSSCALE: 1/2" = 1'-0" CHEMICAL ROOM -PLAN SECTION SCALE: 1/2" = 1'-0"PM-01 1 SECTION SCALE: 1/2" = 1'-0"PM-01 2 SECTION SCALE: 1/2" = 1'-0"PM-01 34'2'1'0 6" SCALE: 1/2" = 1'-0" GRAPHICS SCALE: WATER SAMPLE TAP LOCATIONS NO. DESCRIPTION 1 RAW WATER SAMPLE TAP 2 POST OXIDANT INJECTION WATER SAMPLE TAP 3 POST FILTRATION WATER SAMPLE TAP 4 POST SECONDARY DISSINFECTION INJECTION WATER SAMPLE TAP 5 FINISHED WATER SAMPLE TAP WATER SOFTENER TANK (TYP OF 2) BRINE TANK HIGH SERVICE PUMP (BEHIND FILTER CONTROL PANEL, TYP OF 2) BAGGED GRANULAR SODIUM FLUORIDE STORAGE MOBILE WORK BENCH FLUOFIDE SATURATION SKID 55 GALLON DRUM TANK OVERFLOW TANK VENT TANK FILL EMERGENCY SHOWER/ EYEWASH 1 5 P: 804.782.1903LAKE FREDERICKWATER TREATMENT FACILITYSHEET2100 E. Cary St. Suite 309 | Richmond, VA 23223Engineers | Construction Managers | Planners | Scientistswww.rkk.comResponsive People | Creative SolutionsFREDERICK COUNTY, VIRGINIA - OPEQUON DISTRICTPLAN REVISIONS --SCALEAS SHOWNDATE:ENGINEER:CHECKED:CAD:JOB #: 19142.002SUBMITTALNOT FORCONSTR-UCTION100%11/15/2023 12:24:17 PM\\ad.rkk.com\fs\Cloud\Projects\2019\19124_FredWater\19124.002-Lake Frederick WTP Design\CADD\Revit\Option 3A - Mech 2020.rvtDTAJSJK02/17/2023PM-05TREATMENT BUILDING SECTIONSSECTION SCALE: 1/2" = 1'-0"PM-01 1 WATER SAMPLE TAP LOCATIONS NO. DESCRIPTION 1 RAW WATER SAMPLE TAP 2 POST OXIDANT INJECTION WATER SAMPLE TAP 3 POST FILTRATION WATER SAMPLE TAP 4 POST SECONDARY DISSINFECTION INJECTION WATER SAMPLE TAP 5 FINISHED WATER SAMPLE TAP 4'2'1'0 6" SCALE: 1/2" = 1'-0" GRAPHICS SCALE: 6"2' - 0"6" 1' - 0"1' - 0"1' - 0"1' - 9"2' - 6"DRIP BASIN STRUCTURE BALL VALVE WITH VENT HOLE IN BALL THREADED UNION 1" NIPPLE 6"8 1/2"1 PM-06 1' - 3"1' - 3" 6" THREADED FEMAILE PP C&G FITTING 1' - 0"6" ALL AROUND DRIP RING AROUND PIPE TO PREVENT LIQUID FROM REACHING WALL FILL PIPE (TYP) 2 PM-06 NOTES: 1. DRILL (8) EQUIDISTANT 1/8" DIA HOLES ON THE FRONT FACE OF ALL FILL STATION PLUGS, ALONG THE PERIMETER EDGE. 2. COAT TOP OF CONCRETE CURB AND INTERIOR OF BASIN WITH THE SAME COATING USED IN THE SECONDARY CONTAINMENT AREA WITHIN CHEMICAL ROOM. 3. PAINT EXTERIOR SURFACES OF FILL PIPES AND FITTINGS ACCORDING TO CHEMICAL COLOR CODING.3' - 0"1/2" DRIP RING AROUND PIPE TO PREVENT DRIP LIQUID FROM REACHING WALL THREADED FEMALE PP C&G FITTING PERFORATED PP C&G PLUG, SEE NOTE 1 6"1' - 3"1' - 2"CAST IN PLACE CONCRETE (4,000 PSI STRENGTH) 1" (PVC), INVERT HEIGHT TO ALLOW FULL BASIN DRAINAGE 6" ALL AROUND 1' - 9"DRIP BASIN STRUCTURE BALL VALVE (NO) BALL VALVE (NC) Y-STRAINER SWING CHECK VALVE UNION 2' - 6"VERTICAL PIPE SUPPORT (TYP), SEE DETAIL 6"#4@6" (TYP) EQEQ JOINT SEALANT BACK UP MATERIAL PRECAST BUILDING JOINT FILLER 1/2"4"3 PM-06 NOTES: 1. THE VENT AND INSECT SCREEN SHALL BE MADE OF PE OR PVC. 2. THE INSECT SCREEN SHALL HAVE OPENINGS SIZED BTW 1/8" TO 1/4". EACH INDIVIDUAL SCREEN SHALL HAVE A FREE AREA OF AT LEAST 60% OF THE AREA OF THE PIPE. MAIN VENT PIPE 2"2" INSECT SCREEN SHALL BE SHIELDED AND ARRANGED TO PREVENT POSSIBILITY OF ICICLE FORMATION ON SCREEN SOLVENT WELD 90 DEG BEND PROVIDE UV RESISTANT COATING ON PLASTIC SURFACES EXPOSED TO SUNLIGHT 2 5/8" DIA 316 STAINLESS STEEL ANCHOR BOLTS EACH CLAMP ANCHOR: ATTACH STRAP TO PIPE. GUIDE: FINGER TIGHTEN BOLTS. WALL P: 804.782.1903LAKE FREDERICKWATER TREATMENT FACILITYSHEET2100 E. Cary St. Suite 309 | Richmond, VA 23223Engineers | Construction Managers | Planners | Scientistswww.rkk.comResponsive People | Creative SolutionsFREDERICK COUNTY, VIRGINIA - OPEQUON DISTRICTPLAN REVISIONS --SCALEAS SHOWNDATE:ENGINEER:CHECKED:CAD:JOB #: 19142.002SUBMITTALNOT FORCONSTR-UCTION100%11/15/2023 12:24:18 PM\\ad.rkk.com\fs\Cloud\Projects\2019\19124_FredWater\19124.002-Lake Frederick WTP Design\CADD\Revit\Option 3A - Mech 2020.rvtDTAJSJK02/17/2023PM-06SECTIONS AND DETAILSSECTION SCALE: 1 1/2" = 1'-0"PM-01 1 SCALE: 1 1/2" = 1'-0" FILL STATION PLAN SECTION SCALE: 1 1/2" = 1'-0"PM-02 2 SCALE: 1 1/2" = 1'-0" CHEMICAL VENT TO OUTSIDE SECTION SCALE: 1 1/2" = 1'-0"PM-06 3 NOT TO SCALE VERTICAL PIPE SUPPORT DETAIL S.S. "U" BOLT AND NUTS. WHEN USED WITH PVC OR FRP PIPE, PROVIDE STEEL SHIELD AROUND PIPE AT "U" BOLT WITH LOOSE FIT HEAVY WELDED S.S. BRACKET (GRINELL FIG. 199) HEAVY WELDED STAINLESS STEEL BRACKET BOLTS -SS WITH CHEMICAL CONCRETE ANCHOR, TYPICAL 3/4" COLD WATER SUPPLY TEMPERING VALVE EMERGENCY EYEWASH 3/4" HOT WATER SUPPLY WALL 1" WATER SUPPLY FREEZE PROOF SHOWER VALVE EMERGENCY SHOWER FLAG HANDLE PLAN EMERGENCY SHOWER PULL HANDLE 3/4" HOT WATER SUPPLY 3/4" COLD WATER SUPPLY 1" WATER SUPPLY WALL TEMPERING VALVE EMERGENCY EYEWASH FREEZE PROOF SHOWER VALVE 1 1/4" IPS DRAIN FINISHED FLOOR ELEVATION ANCHOR BOLT (TYP), SEE NOTE 2 3/4" CHAMFER (TYP) #4 AT 12" OC, 1" CL (LAP OPTIONAL) PAD HEIGHT AS REQUIRED, 4" MIN, 2'-0" MAX, SEE NOTE 4 ROUGHEN CONCRETE FLOOR, SEE NOTE 5 4" MINIMUM EMBEDMENT WITH HILTI RE 500, OR APPROVED EQUAL (TYP) NOTES: 1. THE MINIMUM PAD SIZE SHALL BE AS INDICATED OR AS DETERMINED BY THE EQUIPMENT MANUFACTURER. 2. WHEN ANCHOR BOLTS ARE REQUIRED, THE SIZE, NUMBER, TYPE, LOCATION AND THE THREAD PROJECTION OF THE ANCHOR BOLTS SHALL BE DETERMINED BY THE EQUIPMENT MANUFACTURER. HOLD CONCRETE ANCHOR BOLTS IN POSITION WITH A TEMPLATE WHILE PAD IS BEING PLACED. 3. EQUIPMENT BASES SHALL BE INSTALLED LEVEL UNLESS NOTED OTHERWISE ON THE PLANS. 4. FOR EQUIPMENT PADS WITH HEIGHT GREATER THAN XX", THE CONTRACTOR SHALL DESIGN AND SUBMIT A DETAIL TO THE ENGINEER FOR APPROVAL. 5. SURFACE OF CONCRETE SHALL BE ROUGHENED TO A FULL AMPLITUDE OF 1/4"AND SCRUBBED WITH A COARSE WIRE BRUSH TO REMOVE ALL LAITANCE AND TO PROVIDE A ROUGHENED SURFACE FOR BONDING NEW CONCRETE TO EXISTING CONCRETE. APPLY BONDING ADHESIVE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. EPOXY BONDING ADHESIVE SHALL BE "SIKADUR 32, HI-MOD", OR APPROVED EQUAL. 6. EQUIPMENT PADS SHALL BE SUBMITTED TO ENGINEER FOR REVIEW AND APPROVAL. SHOP DRAWINGS SHALL INCLUDE PAD DIMENSIONS AND REBAR DETAILS. SEE PLANS FOR SLAB THICKNESS CRADLE DIA. TO MATCH FITTING FLANGE OD AS REQUIRED STAINLESS STEEL THREADED NUT (WELD TO COUPLING) SCH. 40 STAINLESS STEEL EXTENSION PIPE TO CUT TO SUIT THREAD BOTH ENDS (16"-3", 24"-4") STAINLESS STEEL THREADED COUPLING (WELD TO PLATE) NON-SHRINK GROUT, SEE NOTE 3 TACK WELD AT TWO PLACES ONCE ADJUSTED (TYP. TOP AND BOTTOM) COVER ALL EXPOSED PIPE THREADS W/ WELD AFTER ADJUSTING SUPPORT 8" x 8" x 1/2" STAINLESS STEEL BASE PLATE (WELD) THREADED STUD (16" -1 1/2" x 6", 24"-2" x 6") PIPES UNDER 36" DIAMETER NOTE: 1. PROVIDE STANDON MODEL S89 OR APPROVED EQUAL. 2. DIMENSIONS AND SIZE OF COMPONENTS PER MANUFACTURER'S RECOMMENDATIONS. 3. PROVIDE MINIMUM OF 1" NON-SHRINK GROUT FOR LEVELING. MAXIMUM AMOUNT OF GROUT FOR LEVELING SHALL BE 2.5". GROUT SHALL BE FORMED AS A PAD AS DEPICTED. NOTES: 1. THIS SLEEVE IS TO BE USED BETWEEN DRY SPACES, ABOVE GRADE ONLY. POLYURETHANE SEALANT FINISHED FLOOR 1/4" PLATE WALL FLANGE, MATERIAL SAME AS SLEEVE PIPE SLEEVE, 1/4" THICK MIN. STEEL PIPE THRU FLOOR 3" TYP 1 " 1" CLEARANCE FOUR (4) -1/2" DIA EXPANSION ANCHORS. 4" MIN. EMBEDMENT, DO NOT DAMAGE REINFORCING STEEL IN CONCRETE SLAB UNDERSIDE OF FLOOR SLAB WELDED STEEL ROD ATTACHMENT ADJUSTABLE CLEVIS HANGER PIPE (SIZE REFERENCED IN DRAWINGS) 3/4" DIA. HANGER ROD PL 1/2" x 10" x 10" NOTES: 1. CONTRACTOR TO VERIFY DIMENSIONS IN FIELD AND FURNISH THRUST PIPE WITHOUT SPACERS. 2. THRUST PIPE SUPPORTS INSTALLED FOR FLOOR MOUNTING SHALL HAVE A NON-SHRINK GROUT HOUSEKEEPING PAD SIMILAR TO PIPE CRADLE SUPPORT DETAIL THIS SHEET.SEE NOTEVARIES3/16" PLATE TO MATCH FITTING BOLT PATTERN (TYP. EACH END) STAINLESS STEEL PIPE WALL OR FLOOR, SEE NOTE 2 90 DEG BASE BEND FLxFL PROVIDE AT LEAST FOUR 5/8" DIA. CONCRETE EXPANSION ANCHORS WITH MIN. LENGTH 4-3/4" 3/16"P: 804.782.1903LAKE FREDERICKWATER TREATMENT FACILITYSHEET2100 E. Cary St. Suite 309 | Richmond, VA 23223Engineers | Construction Managers | Planners | Scientistswww.rkk.comResponsive People | Creative SolutionsFREDERICK COUNTY, VIRGINIA - OPEQUON DISTRICTPLAN REVISIONS --SCALEAS SHOWNDATE:ENGINEER:CHECKED:CAD:JOB #: 19142.002SUBMITTALNOT FORCONSTR-UCTION100%11/15/2023 12:24:18 PM\\ad.rkk.com\fs\Cloud\Projects\2019\19124_FredWater\19124.002-Lake Frederick WTP Design\CADD\Revit\Option 3A - Mech 2020.rvtDTAJSJK02/17/2023PM-07DETAILSSCALE: 1 1/2" = 1'-0"PM-04 1 PIPE BRACKET DETAIL SCALE: 3/4" = 1'-0"PM-02 2 EMERGENCY SHOWER EYE WASH SCHEMATIC NOT TO SCALE EQUIPMENT PAD DETAIL SCALE: 12" = 1'-0"PM-02 4 FLANGE PIPE CRADLE SUPPORT DETAIL SCALE: 12" = 1'-0"PM-04 5 FLOOR SLEEVED PIPE OPENING DETAIL SCALE: 12" = 1'-0"PM-02 6 PIPE HANGER SCALE: 1" = 1'-0"PM-02 7 THRUST PIPE SUPPORT DETAIL Responsive People | Creative Solutions Engineers | Construction Managers | Planners | Scientists www.rkk.com P: 804.782.1903 2100 E. Cary St. Suite 309 | Richmond, VA 23223 LAKE FREDERICK WATER TREATMENT FACILITY 02/17/2023100% SUBMITTAL NOT FOR CONSTR- UCTION Scale: 1/2" = 1'-0" TANK ELEVATION VIEW2 19'-318" 24"Ø MANWAY GRAVITY VENT LADDER WITH SAFETY CLIMB AND UPPER PLATFORM SAFETY CLIMB SYSTEM W/ ANTI-SLIP TAPE GRAVITY VENT HWL=591.00' OVERFLOW ELEV.=592.50'12" (FREEBOARD) 53,750 GALLON STEEL STORAGE TANK 22.38'Ø x 19.26' H FLOOR ELEV: 574.25' 8'-0" 8" SCH80 PVC OVERFLOW PIPE (SEE OVERFLOW DETAIL 1, SHEET PM-11) 24"Ø ROOF ACCESS MANWAY (SEE PLAN VIEW FOR ACTUAL ORIENTATION) 6" S.S. FLANGE (RADAR LEVEL TRANSMITTER) ELECTRICAL CONDUIT FOR RADIO LEVEL TRANSMITTER POWER CORD PIPE SUPPORT BRACKET PER THE MANUFACTURER'S RECOMMENDATIONS 12'-0" 2'-0" STAINLESS STEEL PIPE SUPPORT BRACKET COORDINATE INSTALLATION WITH TANK MANUFACTURER TOP OF RINGWALL FLOOR LEVEL CONCRETE PAD FLOW SWITCH TO BE INSTALLED AT OVERFLOW ELEV. TO PROVIDE SIGNAL TO SCADA WHEN OVERFLOW OCCURS ROOF MANWAY Scale: 1/2" = 1'-0" TANK PLAN VIEW1 GRAVITY VENT 8" OVERFLOW 6" S.S. FLANGED PORT (RADAR LEVEL TRANSMITTER HOUSING) 24" ROUND ACCESS SAFETY CLIMB SYSTEM W/ ANTI-SLIP TAPE LADDER/ PLATFORM ASSEMBLY Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTIONGENERAL NOTES: 1.TANK SPECIFICATIONS: FUSED GLASS COATED BOLTED STEEL TANK & ACCESSORIES SHALL MEET REQUIREMENTS OF A.W.W.A. DI03 SPECIFICATIONS. 2.TANK SHALL CONTAIN A MINIMUM OF 53,750 GALLONS WHEN MEASURED TO THE OVERFLOW ELEVATION. 3.TANK HEIGHT AND DIAMETER MAY VARY SLIGHTLY IN ACCORDANCE WITH TANK MANUFACTURER STANDARD DESIGN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CHANGES REQUIRED TO MEET A PARTICULAR TANK DIMENSION. OVERFLOW ELEVATION SHALL BE MAINTAINED. 4.ACCESSORIES TO BE LOCATED AS SHOWN ON THE SITE PLAN OR AS DIRECTED BY THE ENGINEER. BEFORE CONSTRUCTING ACCESSORIES, OBTAIN WRITTEN CONFIRMATION OF LOCATION FROM ENGINEER. 5.DETAILS SHOWN ARE MINIMUM REQUIREMENTS. FINAL DESIGN SHALL MEET AWWA CODE AND MANUFACTURERS REQUIREMENTS. 6.FOUNDATION TO BE DESIGNED BY TANK SUPPLIER. 7.SUBMITTAL DRAWINGS AND CALCULATIONS TO BE STAMPED/SIGNED BY A VIRGINIA PE. Scale: 1/2" = 1'-0" FOUNDATION - PLAN VIEW1 Scale: 1/2" = 1'-0" FOUNDATION - SECTION2 4'-612" LEVELING ASSEMBLIES OUTER FND BOLT CHORD OUTER TIE-BAR CHORD X'-X" 12" X'-X" MAT REBAR Ø22'-49 16" TANK SHELL DIAMETER R9'-25 16" R9'-25 16" 2'-0" 2'-0" 6" D.I. CONCRETE ENCASED SUCTION LINE SEE DETAIL 3, THIS SHEET 6" D.I. CONCRETE ENCASED INLET PIPE SEE DETAIL 4, THIS SHEET 2'-0" R9'-25 16" 4" D.I. DRAIN PIPE 2'-0" TO TANK WALL R11'-27 25" TANK WALL R11'-27 25" C/L OF PIPE 1'-0" MINIMUM CONCRETE EMBEDMENT 75 8" MINIMUM CONCRETE EMBEDMENT 6" 6" D.I. 90° BEND WITH RESTRAINED GLANDS WATERSTOPS 6" D.I. PIPE FOUNDATION SHEET Scale: 3/4" = 1'-0" EFLUENT LINE - SECTION3 SOLID CMU BLOCKS TO WATER TREATMENT PLANT HIGH SERVICE PUMPS 6" 2'-0" TO TANK WALL R11'-27 25" TANK WALL 11'-27 25" C/L OF PIPE 1'-0" MINIMUM CONCRETE EMBEDMENT 75 8" MINIMUM CONCRETE EMBEDMENT 6" 6" D.I. 90° BEND WITH RESTRAINED GLANDS WATERSTOPS 6" D.I. PIPE FOUNDATION SHEET Scale: 3/4" = 1'-0" INLET PIPES - SECTION4 SOLID CMU BLOCKS 12' Long Flanged 6"DIP FROM WATER TREATMENT PLANT FILTER Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTION BRACKET BRACKET 8" SCH80 VAN STONE FLG. STAINLESS STEEL TOP 90° BEND STAINLESS STEEL INTERNAL FUNNEL 12" FREEBOARD 18'-318" MAX. WATER LEVEL 8" SCH80 45° BEND 19'-318" SIDEWALL HEIGHT 3/4" = 1'-0" OVERFLOW DETAIL1 1'-0" 12" 4" 8" FLAP VALVE WITH 24 MESH S.S. SCREEN 8"Ø PIPE 8" SCH80 PVC OVERFLOW PIPE CONCRETE PAD 8'-0" 8"Ø PIPE SAFETY CLIMB DEVICE HORIZONTAL BOLT SEAMS UPPER OBSERVATION PLATFORM RING 1RING 2RING 3RING 4EMBEDDED FND. RING 3/4" = 1'-0" LADDER DETAIL2 Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTION Responsive People | Creative SolutionsEngineers | Construction Managers | Planners | Scientistswww.rkk.comP: 804.782.19032100 E. Cary St. Suite 309 | Richmond, VA 23223LAKE FREDERICKWATER TREATMENT FACILITY02/17/2023100%SUBMITTALNOT FORCONSTR-UCTIONDIRTY BACKWASH BASIN ANDVALVE VAULT - PLANS AND SECTIONPM-12AS NOTEDJABMSMSDIRTY BACKWASH BASIN - TOP PLAN 1 PM-12 DIRTY BACKWASH BASIN - BOTTOM PLAN SECTION 1 1 PM-12 SUBMERSIBLE PUMP 8" CISP DIRTY BACKWASH DRAIN, INV. EL. 568.10℄ SUBMERSIBLE PUMP (TYP OF 2) 2.5" PVC PIPE (TYP) 2.5" PVC TEE 2.5" PVC BEND 2.5" PVC PIPE 2.5" PVC BEND 2.5" PVC BEND 3'-0" x 3'-6" H20 ACCESS HATCH (TYP OF 3) 2.5" TRUE UNION CV 2.5" TRUE UNION BALL VALVE ADJUSTABLE PIPE SUPPORT 3'-0" X 3'-6" H20 ACCESS HATCH 2.5" TRUE UNION CV (TYP OF 2) 2.5" TRUE UNION BALL VALVE (TYP OF 2) LADDER PRECAST CONCRETE VALVE VAULT (5'-0" X 6'-0" INSIDE DIMENSIONS), SEE NOTE 2 PRECAST CONCRETE VALVE VAULT (5'-0" X 6'-0" INSIDE DIMENSIONS), SEE NOTE 2 PRECAST CONCRETE VALVE VAULT (5'-0" X 6'-0" INSIDE DIMENSIONS), SEE NOTE 2 2.5" PVC PIPE 2.5" PVC PIPE (TYP) DIRTY BACKWASH VALVE VAULT - BOTTOM PLAN DIRTY BACKWASH VALVE VAULT - TOP PLAN SECTION 2 ℄ NOTES: 1.SEE UTILITY PLAN C-06 FOR CONTINUATION. CONTRACTOR SHALL MATCH EXISTING 10" FORCE MAIN ELEVATION AND MAINTAIN 4'-0" MINIMUM DEPTH AT STRUCTURES. CONTRACTOR SHALL USE FITTINGS AS NECESSARY TO MAKE FINAL CONNECTION. 2.SEE UTILITY PLAN C-06 FOR LOCATION OF DIRTY BACKWASH VALVE VAULT. 2.5" PVC BEND 8" CISP DIRTY BACKWASH DRAIN, INV. EL. 568.10 8" TEE 8" TEE 8" WATER TANK DRAIN/OVERFLOW 8" WATER TANK DRAIN/OVERFLOW 3'-0" x 3'-6" H20 ACCESS HATCH (TYP OF 3) LADDER LADDER LADDER 2 PM-12 2 PM-12 3'-0" X 3'-6" H20 ACCESS HATCH 1M-01NAD '832M-01M-021SEE SCHEMATIC ON DWG. M28" CISP TO DIRTY BACKWASH BASIN, SEE SITE PLAN FOR CONTINUATION4" DI FIRE, SEE SITE PLAN FOR CONTINUATION2" DOMESTIC WATER, SEE SITE PLAN FOR CONTINUATION4" FLOOR DRAIN (TYP OF 6)4" CISP SANITARY TEE (TYP)8" X 4" RED (TYP)8" X 8" TEE8" X 4" TEE (TYP OF 2)4" CLEANOUT4" CISP1-1/2" CISP1-1/2" CISP2" CISP VENT, 12" MIN THRU ROOF4" CISP, SLOPE 1/4" PER FOOT (TYP)3M-014" CISP WYEB/SUMP572' -0"CHEMICAL ROOM FF572' -6"FINISHED FLOOR574' -3"8" CISP TO DIRTY BACKWASH BASIN, SEE SITE PLAN FOR CONTINUATION4" FLOOR DRAIN4" P-TRAP (TYP)8" SANITARY TEE8" X 4" RED8" X 4" SANITARY TEE (TYP OF 2)4" X 4" SANITARY TEE (TYP OF 2)4" X 4" WYE4" 45° BEND1-1/2" P-TRAPREDUCER1-1/2" 90° BEND (TYP)4" CISP, SLOPE 1/4" PER FOOT (TYP)8" CISP, SLOPE 1/4" PER FOOT (TYP)1-1/2" P-TRAPCHEMICAL ROOM FF572' -6"FINISHED FLOOR574' -3"2" CISP VENT, 12" MIN THRU ROOF2" 90° BEND2" DOMESTIC WATER, SEE SITE PLAN FOR CONTINUATION4" P-TRAP (TYP)4" CISP, SLOPE 1/4" PER FOOT (TYP)4" FLOOR DRAIN1-1/2" CISP1-1/2" 90° BEND (TYP)REDUCER1-1/2" P-TRAPB/SUMP572' -0"FINISHED FLOOR574' -3"8" SANITARY TEESUMP PITP: 804.782.1903LAKE FREDERICKWATER TREATMENT FACILITYSHEET2100 E. Cary St. Suite 309 | Richmond, VA 23223Engineers | Construction Managers | Planners | Scientistswww.rkk.comResponsive People | Creative SolutionsFREDERICK COUNTY, VIRGINIA - OPEQUON DISTRICTPLAN REVISIONS --SCALEAS SHOWNDATE:ENGINEER:CHECKED:CAD:JOB #: 19142.002SUBMITTALNOT FORCONSTR-UCTION100%11/15/2023 12:32:10 PM\\ad.rkk.com\fs\Cloud\Projects\2019\19124_FredWater\19124.002-Lake Frederick WTP Design\CADD\Revit\Option3A - HVAC 2020.rvtMASJABJK02/17/2023M-01PLUMBING PLAN AND SECTIONSSCALE: 1/4" = 1'-0"FINISHED FLOOR -PLUMBINGSECTIONSCALE: 1/4" = 1'-0"M-011SECTIONSCALE: 1/4" = 1'-0"M-012SECTIONSCALE: 1/4" = 1'-0"M-013 WATER HEATERHEAVY DUTY SKID W/ FORK LIFT SLOTSLOCKABLE BALL VALVE (TYP)Y-STRAINERVACUUM ELIMINATORAIR ELIMINATORY-STRAINEROUTLET PRESSURE GAUGETEMPERATURE GAUGES (COLD INLET, HOT INLET AND OUTLET)THERMOSTATIC MIXING VALVE W/ TEMPERATURE OVERRIDE PROTECTIONNOTE:1. TEMPERING SYSTEM, RECIRCULATING PUMP, WATER TANK SHALL BE GUARDIAN MODEL G4110, OR APPROVED EQUAL.EXPANSION TANKCONTROL PANELRECIRCULATION PUMPPRESSURE SWITCHUV WATER PURIFIERWATER HEATERRECIRCULATING PUMP TANKCONNECTION TO EMERGENCY SHOWER TREATMENT BUILDING1-1/2" TEPID WATER SUPPLY1-1/2" TEPID WATER RETURNGATE VALVE (TYP)CONNECTION TO EMERGENCY SHOWER CHEMICAL ROOM3/4" HOSE BIBB IN CHEMICAL ROOM2" DOMESTIC WATERPRESSURE REDUCING VALVEBACKFLOW PREVENTERFLOOR SLEEVE (TYP)GATE VALVE (TYP)3/4" HOSE BIBB IN TREATMENT BUILDING2"2"3/4"3/4"3/4" HOSE BIBB IN TREATMENT BUILDINGSINK3/4"3/4"2"2"1-1/2"1/2"1/2"WALL PENETRATION (TYP)NOTES:1. TEPID WATER PIPING SHALL BE INSULATED.2. GATE VALVES SHALL BE INSTALLED IN CLOSE PROXIMITY TO ALL PLUMBING FIXTURES.3. INSTALL DRAIN PIPING FROM BACKFLOW PREVENTER TO FLOOR DRAIN. DRAIN PIPING SHALL GRAVITY DRAIN, AND SHALL NOT INTERFERE WITH OTHER EQUIPMENT OR OPERATIONS. MANUFACTURER SUPPLIED AIR GAP FITTING SHALL BE INSTALLED BETWEEN THE BACKFLOW PREVENTER AND THE DRAIN PIPING.4. INSTALL BACKFLOW PREVENTER IN AN ACCESSIBLE LOCATION FOR MAINTENANCE. LOCATION SHALL BE APPROVED BY THE OWNER.5. CONNECT TO EYEWASH IN ACCORDANCE WITH IBC PLUMBING CODE, INCLUDING PROVIDING A DRAIN TRAP. 6. COORDINATE THE FLOOR AND WALL SLEEVE LOCATIONS WITH ALL EQUIPMENT AND SUBMIT A WATER PIPING LAYOUT DRAWING TO THE ENGINEER FOR REVIEW.7. MOUNT WATER HEATER SUCH THAT THE ELEVATION OF THE TOP OF WATER HEATER IS BELOW THE SINK ELEVATION AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.8. INSTALL DRAIN PIPING FROM BACKFLOW PREVENTER TO EXTERIOR OF BUILDING AT GRADE LEVEL. DRAIN PIPING SHALL GRAVITY DRAIN TO EXTERIOR, AND SHALL NOT INTERFERE WITH OTHER EQUIPMENT OR OPERATIONS. MANUFACTURER SUPPLIED AIR GAP FITTING SHALL BE INSTALLED BETWEEN THE BACKFLOW PREVENTER AND THE DRAIN PIPING.CONNECTION TO WATER SOFTENER3/4"1-1/2"1-1/2"1/2"1/2"HAMMER ARRESTORSEE NOTE 88" CISP TO DIRTY BACKWASH BASIN, SEE SITE PLAN FOR CONTINUATION4" FLOOR DRAIN (TYP OF 5)4"4"8"8" FLOOR DRAIN IN SUMP PIT4"4"4"4"4" P-TRAP (TYP)4" FLOOR DRAIN IN CHEMICAL ROOM, DRAIN TO SUMP PIT2" VENT MIN 12" THRU ROOF4" CLEANOUT W/ FLUSH MOUNT CAPREDUCER (TYP)ROOF VENT BOOTFLOOR SLEEVE (TYP)CONNECT TO SINKTO SAMPLING STATION IN CHEMICAL ROOM1-1/2"1-1/2"WALL PENETRATION4"2"4"4"4"NOTE:1. ALL PIPING SHALL GRAVITY DRAIN POSITIVELY @ 1/4" PER FOOT MINIMUM.4"4"P: 804.782.1903LAKE FREDERICKWATER TREATMENT FACILITYSHEET2100 E. Cary St. Suite 309 | Richmond, VA 23223Engineers | Construction Managers | Planners | Scientistswww.rkk.comResponsive People | Creative SolutionsFREDERICK COUNTY, VIRGINIA - OPEQUON DISTRICTPLAN REVISIONS --SCALEAS SHOWNDATE:ENGINEER:CHECKED:CAD:JOB #: 19142.002SUBMITTALNOT FORCONSTR-UCTION100%11/15/2023 12:32:11 PM\\ad.rkk.com\fs\Cloud\Projects\2019\19124_FredWater\19124.002-Lake Frederick WTP Design\CADD\Revit\Option3A - HVAC 2020.rvtMASJABJK02/17/2023M-02PLUMBING DETAILSSCALE: 1/2" = 1'-0"M-011TEPID WATER HEATER DETAILSCALE: 1/2" = 1'-0"POTABLE WATER SCHEMATICSCALE: 1/2" = 1'-0"DRAIN PIPE SCHEMATIC 2M-031M-03NAD '83LOUVER L1DAMPER D1DUCT PLENUMEXHAUST FAN EF1LOUVER L2DAMPER D2UNIT HEATER UH1UNIT HEATER UH2UNIT HEATER UH3UNIT HEATER UH4LOUVER L3DAMPER D3LOUVER L4DAMPER D4INDOOR UNIT IU1OUTDOOR UNIT OU13M-033M-01CHEMICAL ROOM FF572' -6"FINISHED FLOOR574' -3"UNIT HEATER UH1UNIT HEATER UH2DAMPER D3UNIT HEATER UH3DAMPER D4FINISHED FLOOR574' -3"CHEMICAL ROOM FF572' -6"FINISHED FLOOR574.25'CHEMICAL ROOM FF572.50'CHEMICAL ROOM FF572' -6"FINISHED FLOOR574' -3"FINISHED FLOOR574' -3"LOUVER L1DAMPER D1PLENUMEXHAUST FAN EF1DAMPER D3FINISHED FLOOR574' -3"FINISHED FLOOR574.25'FINISHED FLOOR574' -3"CHEMICAL ROOM FF572' -6"INDOOR UNIT IDU1OUTDOOR UNIT ODU1P: 804.782.1903LAKE FREDERICKWATER TREATMENT FACILITYSHEET2100 E. Cary St. Suite 309 | Richmond, VA 23223Engineers | Construction Managers | Planners | Scientistswww.rkk.comResponsive People | Creative SolutionsFREDERICK COUNTY, VIRGINIA - OPEQUON DISTRICTPLAN REVISIONS --SCALEAS SHOWNDATE:ENGINEER:CHECKED:CAD:JOB #: 19142.002SUBMITTALNOT FORCONSTR-UCTION100%11/15/2023 12:32:15 PM\\ad.rkk.com\fs\Cloud\Projects\2019\19124_FredWater\19124.002-Lake Frederick WTP Design\CADD\Revit\Option3A - HVAC 2020.rvtMASJABJK02/17/2023M-03HVAC PLAN AND SECTIONSSCALE: 1/4" = 1'-0"FINISHED FLOOR -HVACSECTIONSCALE: 1/4" = 1'-0"M-031SECTIONSCALE: 1/4" = 1'-0"M-032SECTIONSCALE: 1/4" = 1'-0"M-033 P: 804.782.1903LAKE FREDERICKWATER TREATMENT FACILITYSHEET2100 E. Cary St. Suite 309 | Richmond, VA 23223Engineers | Construction Managers | Planners | Scientistswww.rkk.comResponsive People | Creative SolutionsFREDERICK COUNTY, VIRGINIA - OPEQUON DISTRICTPLAN REVISIONS --SCALEAS SHOWNDATE:ENGINEER:CHECKED:CAD:JOB #: 19142.002SUBMITTALNOT FORCONSTR-UCTION100%11/15/2023 12:32:15 PM\\ad.rkk.com\fs\Cloud\Projects\2019\19124_FredWater\19124.002-Lake Frederick WTP Design\CADD\Revit\Option3A - HVAC 2020.rvtMASJABJK02/17/2023M-04HVAC DETAILS AND SCHEDULESDUCTLESS MINI-SPLIT SYSTEM INDOOR UNIT SCHEDULEDUCTLESS MINI-SPLIT SYSTEM OUTDOOR UNIT SCHEDULEREMARKS:INSULATE REFRIGERANT PIPING.1.ODU-1MARKOUTDOOR9,000PROPELLER10.67208-230/60/1MITSUBISHISUZ-KA09NAHZ1,3CAPACITYLOCATIONBTUHRATED COOLINGDATANOTYPEVOLTS/HZ/PHASEF.L.A.FAN DATAELECTRICALMODELMANUFACTURERREMARKS1. INSTALLATION PLATEREMARKS:REMOTE CONTROLLER HOLDER2.IDU-1CHEMICAL ROOM9,00011,0000.20MITSUBISHISLZ-KF09NA1,2.3CAPACITYLOCATIONTOTALCOOLINGF.L.A.CFMFANMANUFACTURERMODELREMARKS3. WIRED REMOTE CONTROLLERWIND BAFFLE2.CAPACITYHEATINGTOTAL207-33511,000CAPACITY AT 47° FBTUHRATED HEATING20.2SEER14MCA129WEIGHTLBSR410AREFRIGERANTTYPEAAA208-230/60/1DATAVOLTS/HZ/PHASEELECTRICAL0.25MCAAMOUNTING BRACKET > 24" ABOVE GRADE3.D1REMARKSDEPTH(INCHES)SIZEID(INCHES)MATERIALTYPENOTESALUMINUM7.8.REAR FLANGE FRAME9.SPRING LOADED CLOSEDSPRING LOADED OPEN5.4.6.ACTUATOR MOUNTING BRACKETSWITCH PACKAGEFRONT FLANGE FRAME2.1.3.CLEAR ANODIZED FINISHPNEUMATIC ACTUATORELECTRIC ACTUATOR4OPEN WHEN EXHAUST FAN EF1 IS OPERATING,OTHERWISE CLOSED1,3,4,6,7,9NOTES:36" x 36"THIN LINECONTROL DAMPERMANUFACTURER& MODEL NO.NOTESKWID7'-0" AFF15UH1QMARK MODEL MUH-15,OR APPROVED EQUAL1,2,3,4MOUNTINGHEIGHTNOTES:1.PROVIDE INTEGRAL THERMOSTAT2.MOUNTING HEIGHT IS TO BOTTOM OF UNIT3.PROVIDE INTEGRAL DISCONNECT4.SEE ELECTRICAL DRAWINGS FOR CONNECTION REQUIREMENTS21.75" X 19" X 12.75"SIZE(H X W X D)GREENHECK MODEL NO. BSQ-180-71, ORAPPROVED EQUALTREATMENT BUILDING0.25EF1EXHAUSTDRIVELOCATIONSERVICEIDCFMS.P.(IN W.G.)FAN RPMNOTESMANUFACTURER & MODEL NO.BELT3,300891460/3VOLTAGE/ PHASEMOTORHP0.7516. FLOOR MOUNTED RUBBER-IN-SHEAR INSULATORS17. CEILING MOUNTED SPRING ISOLATORS18. FLOOR MOUNTED SPRING ISOLATORS1.NEMA 4 DISCONNECT9.INLET GUARD10. OUTLET GUARD11. INLET FLEXIBLE CONNECTOR12. OUTLET FLEXIBLE CONNECTOR13. FLANGED INLET CONNECTION WITH COMPANION FLANGE14. FLANGED OUTLET CONNECTION WITH COMPANION FLANGE15. CEILING MOUNTED RUBBER-IN-SHEAR INSULATORS20. EPOXY POWDER COATING19. LORENIZED COATING21. REINFORCED WHEEL28. THERMOSTATICALLY CONTROLLED25. EXTENDED LUBE LINES26. SPARE BELT KIT27. BELT TENSIONER-ROTARY2.GRAVITY BACKDRAFT DAMPER3.MOTORIZED BACKDRAFT DAMPER4.SIDE DISCHARGE PACKAGE5.DUEL SIDE DISCHARGE PACKAGE6.BELT GUARD7.OSHA GUARD/MOTOR COVER8.INSULATED HOUSING22. EXTERNAL INLET VANE DAMPER -ALUMINUM23. FILTER BOX WITH ALUMINUM FILTER24. FILTER BOX WITH 30% ALUMINUM FILTER7,9,12,14,17,19,21,25,26,27,28NOTES:63 dBASOUND(MAXAT 5FEET)7'-0" AFF15UH21,2,3,47'-0" AFF15UH31,2,3,4D2ALUMINUM41,3,4,6,7,936" x 24"THIN LINECONTROL DAMPERQMARK MODEL MUH-15,OR APPROVED EQUALDAMPER SCHEDULEUNIT HEATER SCHEDULECENTRIFUGAL SQUARE INLINE FAN SCHEDULE21.75" X 19" X 12.75"21.75" X 19" X 12.75"QMARK MODEL MUH-15,OR APPROVED EQUAL7'-0" AFF15UH41,2,3,4QMARK MODEL MUH-15,OR APPROVED EQUAL21.75" X 19" X 12.75"D3ALUMINUM41,3,4,6,7,936" x 24"THIN LINECONTROL DAMPERD4ALUMINUM41,3,4,6,7,936" x 24"THIN LINECONTROL DAMPERREMARKS4DEPTH(INCHES)APPROXIMATESIZE (W X H)ID.L1ALUMINUMMATERIAL1,6,11TYPENOTES11.6.5.7.FILTER RACKSBIRD SCREENINSECT SCREEN2.1.4.3.EXTENDED SILLHINGED FRAMENOTES:FRONT SECURITY BARSREAR SECURITY BARS12.KYNAR FINISH13.CLEAR ANODIZED9.10.BAKED ENAMEL FINISHEPOXY FINISHTOPELEVATION587.2536" X 36"4" STATIONARYLOUVERSEE DAMPER D1,DAMPER SCHEDULECOLOR ANODIZEDPRESSURE DROP(INCHES OF WATER)0.108.PRIME COAT FINISH14.OPPOSED BLADE DAMPER4L2ALUMINUM1,6,11584.5036" X 24"4" STATIONARYLOUVERSEE DAMPER D2,DAMPER SCHEDULE0.10LOUVER SCHEDULE4L3ALUMINUM1,6,11584.5036" X 24"4" STATIONARYLOUVERSEE DAMPER D3,DAMPER SCHEDULE0.104L4ALUMINUM1,6,11585.7536" X 24"4" STATIONARYLOUVERSEE DAMPER D4,DAMPER SCHEDULE0.10OPEN WHEN EXHAUST FAN EF1 IS OPERATING,OTHERWISE CLOSEDOPEN WHEN EXHAUST FAN EF1 IS OPERATING,OTHERWISE CLOSEDOPEN WHEN EXHAUST FAN EF1 IS OPERATING,OTHERWISE CLOSEDODU-1 REFRIGERATION PIPING AND WIRING SCHEMATIC001SLZ-KF09NAGp1PAR-40MAA208-230V/60HzFUSESUZ-KA09NAHZIDU-1Chemical RoomP1ODU-1NTSPREFABRICATED BUILDING WALLINTERIOREXTERIORNTSEXTENDED SILLSEALANTALL AROUNDALUMINUMBIRD SCREENLOUVERTYPICAL LOUVER/DAMPER INSTALLATION DETAILDAMPERFAN EF1 (IF APPLICABLE)(TYP ) 1 0 ° MI N TRANSITION DUCT TO EF1 CRAPPIE COURT(PRIVATE) DTB DTB CMB Responsive People | Creative Solutions Engineers | Construction Managers | Planners | Scientists www.rkk.com P: 804.782.1903 2100 E. Cary St. Suite 309 | Richmond, VA 23223 100% SUBMITTAL NOT FOR CONSTR- UCTION LAKE FREDERICK WATER TREATMENT FACILITY 02/17/2023 19124.002