Loading...
HomeMy WebLinkAbout23-09 Blue Ridge Industries - Hazardous Storage Bldg. - Shawnee - Backfile (2)64-A-80K MAIN OF WINCHESTER LLC ZONED: M-1 64-A-80S H B Et J LLC ZONED: M-1 _SZT36-01 -E 501.49' S60*2359"W 8.77' --------- 25' BRIL f _j CC) Grass Area I EU� Grass Area EXISTING INDUSTRIAL BUILDING C4 FF ELEV=701.90 --- - — 24'x9.3' HAZARDOUS MATERIALS BUILDING ELECTRIC SERVICE TO BE EXTENDED 25yOOO S.F. 1515' t FROM EXISTING BUILDING MINIMUN 2 HR RATING PROVIDED. REMOVE EXISTING PARKING SPACE 1 1 25 SPACq1S I I I STRIPE OF FOR 0_j6 _T NO PARKING < U _j W 28 SPACES I I L IT _j 5.r 25' BRL 705.81' PENDLETON DRIVE CONSTRUCTION NOTES C'[^KI['DA1 I . The contractor shall furnish oil materials, labor and equipment and perform all work including restoration for the completed installation of the utility systems and all other improvements shown or implied as necessary for the completed facility ready for use. Unless otherwise noted, s fications for all work to be in accordance with applicable Standards and Construction Specifications of The inia Department of Transportation, Virginia Department of Health, Frederick County Sanitation Authority E� !�� contract documents. 2. The engineer has attempted to locate existing subsurface utilities; however, such may exist that are not shown. The contractor shall exercise care this work so as to avoid damage to any utilities. Any damage shall be the contractor's res onsibility. The contractor shall notify all utility companies 72 hours prior to construction. Call "Miss Utilit�h 1-800152-7001. 3. e contractor shall be responsible for all construction stakeout. All dimensions, elevations and locations shall be verified in the field by each contractor prior to beginning the work. The Engineer will approve all cut sheets. 4. Contractor to obtain, at his expense, all permits required of this work and shall faithfully adhere to the permit conditions imposed. -FIRE & RESCUE 1. Burning of land clearing debris requires a permit from the Fire Marshal. Burning of construction debris on site is prohibited. 2. Access for emergency vehicles must be maintained at all times during construction. Temporary street signs and addresses must be posted as construction begins. Parked veh I cles and staging of construction materials are prohibited n within 20' of fire hydrants. Fire Hydra�ts ore not to be obstructed at any time. 407.4.01114CACWF 20 10 0 20 40 //V FEET I Inch = 20 ft. OWNER /DEVELOPER BLUE RIDGE INDUSTRIES P.O. BOX 1847 WINCHESTER, VA 22604 (540) 667-3900 SITE PLAN APPROVALS: SP-045-89 APPROVAL 11/03/09 SP-017-91 APPROVAL 09/20/91 SP-009-93 APPROVAL 04/9/93 SP-042-03 APPROVAL 12/09/03 64-A-801 1W_ HILL HARRY TRUSTEE 0 FOR AVIS HILL TRUST ZONED: M-1 0 ca SITE PLAN APPROVAL NAME T W ,-, DATE SITE PLAN NUMBER Approved by Frederick County Zoning Administrator �2 Dote SITE PLAN VALID FOR FIVE (5) YEARS FROM APPROVAL DATE. _j PROJECT SUMMARY 00 __j < z Of -2 ,1- yLr C) TAX IDENTIFICATION NUMBER 64-A-80Q 0 LW < V) 0 0 Wwo - b EXISTING PARCEL AREA 5.36 acres co (f) E N P= 0 CD U_ UJ C) LU X DEVELOPED PARCEL AREA 4.36 acres Lli LL_ 0 0 ZONING M-1 00� a_ 00 ADDRESS 266 ARBOR COURT CURRENT USE INDUSTRIAL PROPOSED USE INDUSTRIAL DISTURBED AREA 300 SO. FT. co SETBACK REQUIREMENTS G) W :t REQUIRE PROVIDED FRONT (PRIMARY HIGHWAY) 75' 305.7' SIDE (NORTH) 25' 30.5' < SIDE (SOUTH) 25' 375 Q) BUILDING HEIGHT 60' 9' 0 (�L C) 4_ V) PARKING REQUIREME SPACES 0 U) C"A 0-) V-) REQUIRED 3 PER 4 EMPLOYEES (75 EMPLOYEES) 56 0 C: rr) C)) STANDARD SPACES REQUIRED 53 0 < > STANDARD SPACES PROVIDED 53 __j L: REQUIRED HANDICAP SPACES 3 co (D PROVIDED HANDICAP SPACES 3 �1_ Q) -+- �D (D V) U) TOTAL SPACES PROVIDED 56 U) C C 0 Q) IJj -C 0 0 C) ;I- zj- C) Ln Lr) a_ i,- LL HAZARDOUS STORAGE BUILDING SPECIFICATIONS MFG. PARKILINE BUILDING SYSTEM TYPE HAZARDOUS STORAGE BUILDING SERiESJ HMS-2 2 HOUR FIRE RATED CONSTRUCTION MAXIMUM CAPACITY 44 0 55CAL DRUM OR EQUIVALENT GALLONS DIMENSIONS 24' x g'-4" XTf)W1Q- 1. BUILDINGS SHALL COMPLY WITH THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE AND SECTIONS 307, H (HAZARDOUS STORAGE) OF THE INTERNATIONAL BUILDING CODE/2006. OTHER CODE THAT APPLIES IS ICC ANSI A117.1-3-03 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES. STRUCTURAL PLANS SUBMITTED FOR PERMIT APPLICATION SHALL BE SEALED BY A VIRGINIA LIC[NSED DESIGN PROFESSIONAL. 2. PROPOSED 216 SQ. FT SINGLE STORY PREFABRICATED HAZARDOUS STORAGE BUILDING SHALL BE ANCHORED TO PROVIDE UPLIFT PER IBC 2006. BUILDING IS RATED FOR TWO HOURS. MANUFACTURE SPECS SHALL BE SUBMITTED WITH APPLICATION FOR BUILDING PERMIT. BUILDING SHALL BE LOCATED MORE THAN 15' FROM EXISTING BUILDING (T602-WALL RATINGS). HAZARDOUS USE GROUPS ARE REQUIRED TO BE DESIGNED BY RDP ELECTRIC SHALL BE INSTALLED PER NEC 2005. h0m. 1. DISTURBANCE IS LESS THAT 300 SO. FT. SO NO E&S CONTROL REQUIRED. 2. NO INCREASE IN IMPERVIOUS AREA IS PROPOSED WITH THIS PLAN. FIM L-ANM F1E<XJF19w§BNM connections, curbing not delineated as parking, and all normal and emergency access points to the structure. The contractor shall coordinate with the Fire arshol a ensure t ese requirements are satisfied. LEGEND ZONING BOUNDARY ........................ ZB UTWY PEDESTALS ------------------------ [1] nE DOSTING STORM DRAINAGE & STRUCTURE .............. = ==O-- = = = = D(ISTING EDGE OF PAVEMENT . . . . . . . . . . . . . . . . . . .. - - - - - - - - LOCATION MAP SCALE: 1 "=1 500' z 0 V) U-) Cn :z Uj CD CD z 0 LIJ Li CD U < <C C11 CD W UJ UJ Cn U� U) U-) Li Uj cr_ 01� r� M C) C�l MOIR 0 U) + 0 LLJ Lij C/) LLJ M W -Z N 0 L.LJ 25 n (D LJ 0 a: U) W, Z W a LLJ W U LLJ M 0 V) (7111 0 0 -0 C14 3: II-_ 0 0 cn :3 LLJ > LLJ -- F_ Ld _j < L.Li Ljj Cn < 0 U) IL W 1­_ V) 0 C:) 0 L1.j 0 0 (10 LLJ < Q� 0 L-1-1 :I-- LLJ _j 04 0 0 64-A-80K MAIN OF WINCHESTER LLC ZONED: M-1 64-A-80S H B Et J LLC ZONED: M-1 ._.,SZT36'01 -E 501.49' S60'23'59 8.77' 25' BRL Grass Area Grass Area. EXISTING INDUSTRIAL BUILDING FF ELEV=701.90 24'x9.3' HAZARDOUS MATERIALS BUILDING - ------ -30 15.5- ELECTRIC SERVICE TO BE EXTENDED 25yOOO S.F. I - I F lr.TlNr.. RIAnnimin. P r-1 MINIMUN 2 HR RATING PROVIDED. Ra,AOVE EXISTING :7: PARKING SPACE 25 SPAC9&'S STRIPE OF FOR NO PARKING < CL ton im d 28 ISPACES 1— 4— —i —1 1— f— + —4 ----11 Jj r 25' BRL 305. r 705.81 PENDLETON DRIVE GENERAL CONSTRUCTION NOTES - 1. The contractor shall furnish all materials, labor and equipment and perform all work including restoration for the co pleted installation of the utilityUs shown or implied as necessary for the nZems and all other improvements completed facility ready for use. ess otherwise noted, s fications for all work to be in accordance with a licable Standards and Construction Specifications of The inia lep ' rtment of Transportation, Virginia Dpe'partment of Health, Frederick County Sanitation Authority Zjr� the contract documents. 2 . The engineer has attempted to locate existing subsurface utilities; however, such may exist that are not shown. The contractor shall exercise care in this work so as to avoid damage to any utilities. Any damage shall be the contractor's responsibility. The contractor shall notify all utility companies 72 hours prior to construction. Call "Miss Utilit�" 1-800-552-7001. 3. he contractor shall be responsible for all construction stakeout. All dimensions, elevations and locations shall be verified in the field by each contractor prior to beginning the work. The Engineer will approve all cut sheets. 4. Contractor to obtain, at his expense, all permits required of this work and shall faithfully adhere to the permit conditions imposed. FIRE & RESCUE 1. Burning of land clearing debris requires a permit from the Fire Marshal. Burning of construction debris on site is prohibited, 2. Access for emergency vehicles must be maintained at all times during construction. Temporary street signs and addresses must be posted as construction begl ns. Porked vehicles and sta, , of construction materials are prohibited t�,n within 20' of fire hydrants. Fire Hydrants are not to be obstructed at any me. 4 GRM01110 4 94 CW, F 20 10 0 20 40 9 IMM 6mmmmmmw� ( IN FEET ) I Inch = 20 ft. OWNERIDEVELOPER BLUE RIDGE INDUSTRIES P.O. BOX 1847 WhICHESTER, VA 22604 (540) 667-3900 SITE PLAN APPROVALS: SP-045-89 APPROVAL 11/03/09 SP-017-91 APPROVAL 09/20/91 SP-009-93 APPROVAL 04/9/93 SP-042-03 APPROVAL 12/09/03 64-A-801 FW- HILL HARRY TRUSTEE 0 FOR AVIS HILL TRUST U ZONED: M-1 SITE PLAN APPROVAL NAME DATF SITE PLAN NUA�', Approved by Frederick County Zoning Administrator SITE PLAN VALID FOR FIVE (5) YEARS FROM APPROVAL DATE. Date PROJECT SUMMARY TAX IDENTIFICATION NUMBER 64-A-800 EXISTING PARCEL AREA 5.36 acres DEVELOPED PARCEL AREA 4.36 acres ZONING M-1 ADDRESS 266 ARBOR COURT CURRENT USE INDUSTRIAL PROPOSED USE INDUSTRIAL DISTURBED AREA 300 SQ. FT. SETBACK REQUIREMENTS REQUIRE PROVIDED FRONT (PRIMARY HIGHWAY) 75' 305.7' SIDE (NORTH) 25' 30.5' SIDE (SOUTH) 25' 375 BUILDING HEIGHT 60' 9' PARKING REQUIREME SPACES REQUIRED 3 PER 4 EMPLOYEES (75 EMPLOYEES) 56 STANDARD SPACES REQUIRED 53 STANDARD SPACES PROVIDED 53 REQUIRED HANDICAP SPACES 3 PROVIDED HANDICAP SPACES 3 TOTAL SPACES PRO14DED 56 HAZARDOUS STORAGE BUILDING SPECIFICATIONS MFG. PARKLINE BUILDING SYSTEM TYPE HAZARDOUS STORAGE BUILDING SERi HMS-2 2 HOUR FIRE RATED CONSTRUCTION MAXIMUM CAPACITY 44 0 55CAL DRUM OR EQUIVALENT GALLONS DIMENSIONS 24' x 9'-4' NOTES: 1. BUILDINGS SHALL COMPLY WITH THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE AND SECTIONS 307, H (HAZARDOUS STORAGE) OF THE INTERNATIONAL BUILDING CODE/2006. OTHER CODE THAT APPLIES IS ICC ANSI A117.1-3-03 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES. STRUCTURAL PLANS SUBMITTED FOR PERMIT APPLICATION SHALL BE SEALED BY A VIRGINIA LICENSED DESIGN PROFESSIONAL. 2. PROPOSED 216 SQ. FT SINGLE STORY PREFABRICATED HAZARDOUS STORAGE BUILDING SHALL BE ANCHORED TO PROVIDE UPLIFT PER IBC 2006. BUILDING IS RATED FOR TWO HOURS. MANUFACTURE SPECS SHALL BE SUBMITTED WITH APPLICATION FOR BUILDING PERMIT. BUILDING SHALL BE LOCATED MORE THAN 15' FROM EXISTING BUILDING (T602-WALL RATINGS). HAZARDOUS USE GROUPS ARE REQUIRED TO BE DESIGNED BY RDP ELECTRIC SHALL BE INSTALLED PER NEC 2005. NOTF- 1. DISTURBANCE IS LESS THAT 300 SO. FT i SO NO E&S CONTROL REQUIRED. 2. NO INCREASE IN IMPERVIOUS AREA IS PROPOSED WITH THIS PLAN. L-ANM FC-CKJ1V9WE3`TM Fire Lane markings and signage is required at all fire hydrants, fire department connections, curbing not delineated as parking, and all normal and emergency access points to the structure. The contractor shall coordinate with the Fire Marshall to ensure these requirements are satisfied. LEGEND ZONING BWNDARY ........................ Z8 UTILITY PEDESTALS ........................ nT 10 EXISTING STORM DRAINAGE & STRUCTURE .............. = ==[3-- = = = = EXnNG EDGE OF PAVEMENT . . . . . . . . . . . . . . . . . . .. — — — — — — — — LOCATION MAP SCALE: 1"=1500' LU 6a� :5 -5 CF) co co C) z 0 V) C) C) z 0 LLJ Ld < < C�l c:) LLI LL, U-1 Cf) V) U) Ln 1-1i LIJ 121:� ft� son A C5 cc> "S 0, L" 0 :2 '03 ON of L, �3 Laf Li LL- 0 0 Of a- A� iv 00 (D 0 :t < Q) Z 0 C) 0 co Cot -0 7U C: C) < 0 > -j . a- U-) U) C-0 (D Q0 CD U) U) Q) 0 0) C: LA 0 (D r-, c in if) LL 0 + 0 C 0) C IL Lj LJ Cn W M z LLJ oy 0 C/) :n W W Z W a LLJ 0 3c: 1 La E n US M 0 ft� V) 0 W Lli N o 11- 0 LL- 0 LLJ > M LJ 1--- _j < U]l < C� U Cf) Cf) 11-- V) 0 C) Z 0 L) z LLJ y 0 Z 0 (f) 3- < 0 Ld Li L-1 Df T- C) --i