HomeMy WebLinkAbout19-11 CNG Station - Office, Garage, Storage - Shawnee - Backfile (2)*ULL�WPALZ L./iTLZ - )ZOUTZ F*7 'ft x Yt �0T L 522 I LOCATION M A P '❑SED 30' X 26' COMPRESSOR PAD AND CANOPY, 1 2,500 -R TO STRUCTURAL PLANS A-1 AND A-2, = 'ABED BY GE❑RGE C. GERBER, RE, CONCRETE SLAB SHALL MATCH EXISTING -MENT ELEVATIONS, THE CANOPY HEIGHT SHALL 8.5 FEET ABOVE THE MEAN GROUND LEVEL, PROPOSED CANOPY C❑NTAINS 4 RECESSED TS, REFER TO LIGHTING PLAN AND ATTACHED -ER PREPARED BY C,W, ROBINSON ELECTRIC, INC, ADDITIONAL INF❑RMATION, EXISTING GAS PUMPS AND UNDERGROUND STORAGE TANKS PREVI❑USLY REMOVED SEE LETTER ATTACHED THIS SHEET, COMMONWEALTH EALT. of V11 R14 `1N1 DEPARTMENT OF ENVIRONMENTAL QUALITY VALLEY REGIONAL OFFICE 1- P'r: ton fii v2rll Jr- 4411 Rwld, P.O. Box 3000,14arrisonbra.1. Virginia 22$(.i 1 .-5c'L'li :zry Of \il[M-al ReSotIrces 1540 j 5 4--WO F-.ax (5-40 ) 5 f 4-78 7 8 a t�,• w' . deq, virg i r. i:t. go v September 1.3, 200S Mr. John Puddy Washington Cia-s Co. 6801 Industrial Drive Springfield, VA 22I51 Re: Closure Assessment Report Review Facility ID: 600617, Washington Gas Co. Shenandoah Station, 350 Hillandale Ave. Winchester. VA Dear Mr. Puddy: Da id K. 1)20of Dirye,or lrntir "!•Hatcher 0 v .!!" €Z�3.l Oiicfl �Il c't C6r The Department of Environmental Quality (DEQ) Valley Regional Office received a complete Closure Assessment Report (which includes the Notification for Underground Storage Tanks Form 7530-1) for the above referenced site on September 12, 2008. Review of this report suggested that the Underground Storage Tank (UST) system located at this facility did not have contamination levels that warrant further assessment. Should future environmental problems arise in this vicinity, additional testing and corrective actions may be required in accordance with State Law. DF1'Q appreciates the responsible manner in which you handled this matter. If you have any questions, please feel free to contact: one at (540)574-7803 or n�hasn-�a(�%deq.virgin.i.a_gi.>v. KS CC.' Compliance File I-A-TroN � us� PROJECT SUMMARY: ❑U .SLY 7VED LOT SHOWN: THE PROPERTY DEPICTED HEREON KNOWN AS; PARCEL ID NUMBER (PIN) 63—A-2, RECORD ID NUMBER 41044, AND IS LOCATED AT 350 HILLANDALE LANE IN FREDERICK COUNTY VA. THIS PARCEL REPORTEDLY CONTAINS 10.985 ACRES OF LAND. AND IS ZONED M-1 THE USE OF THIS PROPERTY IS: OFFICE, GARAGE & STORAGE SET BACK REQUIREMENTS FOR THIS SITE: FRONT YARD = 75' REAR YARD = 25' SIDE YARD = 25' THE OWNER / DEVELOPER INFORMATION FOR THIS SITE IS; WASHINGTON GAS LIGHT COMPANY, LOCATED AT 6801 INDUSTRIAL DRIVE SPRINGFIELD VA, 22151. THIS MINOR SITE PLAN HAS BEEN PREPARED BY; DELASHIMUTT ASSOCIATES LTD., ENGINEERS AND LAND SURVEYORS ARLINGTON, VIRGINIA 1 deloshmutt®compuserve.com cal 703 48 6-8300 z I THIS MINOR SITE PLAN IS PREPARED IN CONJUNCTION WITH SITE PLAN REVISION #0994, ENTITLED "SITE PLAN, 0 q, PROPOS'ED BUILDING ADDITION, SHENANDOAH GAS CC 1u -- CO. - KERNSTOWN", DATED DECEMBER 3, 1993, WAS PREPARED BY H. BRUCE EDENS, L.S., OF GREENWAY INC. en LU THE MINOR SITE PLAN IS INTENDED AS AN ADDENDUM ASSOCIATED WITH SITE PLAN REVISION #0994 TO IDENTIFY THE PROPOSED LOCATION OF A 30' X 26' COMPRESSOR PAD AND CANOPY. THIS PLAN DOES NOT ALTER THE, SITE DATA, SET BACK REQUIREMENTS, BUILDING HEIGHT, FLOOR ,AREA TO LOT AREA RATIO, PARKING SUMMARY OR THE LANDSCAPE AREA TABULATION AS SHOWN ON THE SITE PLAN REVISION #0994. l� APPROVED BY: �z ONING A MINISTRATOR DATE SITE PLAN VALID FOR (5) YEARS FROM DATE OF ZONING ADMINISTRATOR APPROVAL. Sincerely, ;. Mike Asnia Petroleum Facility Inspector THE ABOVE LETTER RECEIVED BY WASHINGTON GAS CO. FROM THE COMMONWEALTH OF VIRGINIA, DEPARTMENT OF ENVIRONMENTAL QUALITY IS ADDED HEREON TO VERIFY REMOVAL OF UNDERGROUND STORAGE TANKS. ACCORDING TO THE LETTER THE UNDERGROUND STORAGE TANKS WERE REMOVED AND A REPORT WAS FILED SUGGESTING THAT THERE WAS NO CONTAMINATION LEVELS FOUND THAT WARRANT FURTHER ASSESSMENT. Q-2� i' CC W. Robinson Electric, Inc. 14004-L Willard Rd., Chantilly, VA 20151-2929 (703) 802-9000 FAX (703) 802-9004 July 27, 2011 Delashmutt Associates 1120 S. George Mason Dr. Arlington, Virginia 22204 Attention: Mr. Rick Bevan Prarect: Shenandoah Gas 350 Hillandale Lane Winchester, Virginia 22602 Subject: Canopy Lighting for Compressed Natural Gas Facility. Dear Mr. Bevan: As per our conversation today, I have reviewed Frederick County zoning section 165-201-07 (.Outdoor lighting standards for nonresidential uses). I feel that we are in compliance with their requirements for the canopy lighting that is to be installed. Drawing E-1 shows the locations of the lights and they are recessed within the underside of the canopy to ensure that no light source is visible from or causes glaze on adjacent properties or road rights -of way. Please do not hesitate to contact me if you need any further information. Very truly yours, C. Wayne Robinson President (Master Electrician) 0 J V) Ld Q U 0 to a D v1 Q J W O r` 0 0 N 0 GRAPHIC SCALE 30 0 15 30 60 120 Ca. o0uAsN �� �r��Ta4hnuW �A `�+t� � � 1-11fF -�-�� (�i __,I_r_ A14,--4- L i _ _ _ `_r= �J J_ r__t I_ i _�1�i _y T". CIVIL ENGINEERS & LAND SURVEYORS 1120 S. GEORGE MASON DR. ARLINGTON, VIRGINIA 22204 (703) 486-8300 MM 0 R S� T E PLAN SHOWING PROPOSED COMPRESSED NATURAL GAS STATION WASHINGTON GAS LIGHT COMPANY PROPERTY FORMERLY SHENANDOAH GAS COMPANY PROPERTY — KERNSTOWN S H AW N E E DISTRICT FREDERICK COUNTY, VIRGINIA SCALE.- 1"= 30' DATE. MAY 20, 2011 TA X MA P„ ( FIELD BOOK.JL4�aII DRAWN BY. RB DRAWING: 11-1os.owG SETTINGS FILE.- ( IN FEET) t inch = 30 ft. CHECKED B Y. I6�9�11 NEW PROPOSED COMPRESSOR PAD AND CANOPY RB JOB NO.: 11-109 FILE NO.: SHEET , OF N0. DATE DESCRIPTION i 13Y *ULLA-11(,PAL4 LAW4 - )ZOU7T, F4T7 PROPOSED CANOPY CONTAINS 4 RECESSED TS, REFER TO LIGHTING PLAN AND ATTACHED ER PREPARED BY C,W. ROBINSON ELECTRIC, INC, ADDITIONAL INF❑RMATI❑N, EXISTING GAS PUMPS AND UNDERGROUND STORAGE TANKS PREVI❑USLY REMOVED SEE LETTER ATTACHED THIS SHEET, '5 DEPARTMENT OF ENVIRONMENTAL QUALITY VALLEY REGIONAL OFFICF L. Pr¢sEon Bri xa_..Ir_ 4411 Early R01d, R0. Box 3000, Harrisonbuia. Virgii7ia 22801 Secrci 1 r.,Y vacttfal R uxn'ce.s i 540) f=i1.x (540) 5 74_78 R .v w w . deq. :•i rg i r, i a. go •: September 121, ?008 Mr. John Puddy Washington Gas Co. 6801. Industrial Drive Springfield, VA 227151 Re: Closure Assessment Report Review Facility ID: 600617, Washington Gas Co. Shenandoah Station, 350 Flillandale Ave. Winchester. VA Dear Mr, Puddy: Dt is K P;w}czr Director arny.1 hatcher O�•� ! € ru'iorf:,! Nc�:tor The Department of Frivironrnental Quality (DEQ) Valley .Regional Office received a complete Closure Assessment Report (which includes the Notification for Underground :Storage Tanks Form 7530-1) for the above referenced site on September 12, 2008. Review of this report suggested that the Underground Storage Tank (UST) system located at this facility did not have contamination levels that warrant further assessment. Should future environmental problems arise in this vicinity, additional testing and corrective actions may be required in accordance with State Law. I:D;Q appreciates the responsible manner in which you handled this matter. If' you have any questions, please feel free to contact the at (540)574-7803 or nihasma(i.. deq.virginia. �,,ov. ouN� cc: Compliance File KS 7".+T70Tf T T,usT_ PROJECT SUMMARY: RSLY ]VED LOT SHOWN: THE PROPERTY DEPICTED HEREON KNOWN AS; PARCEL ID NUMBER (PIN) 63—A-2, RECORD ID NUMBER 41044, AND IS LOCATED AT 350 HILLANDALE LANE IN FREDERICK COUNTY VA. THIS PARCEL REPORTEDLY CONTAINS 10.985 ACRES OF LAND. AND IS ZONED M-1 THE USE OF THIS PROPERTY IS: OFFICE, GARAGE & STORAGE SET BACK REQUIREMENTS FOR THIS SITE: FRONT YARD = 75' REAR YARD = 25' SIDE YARD = 25' THE OWNER / DEVELOPER INFORMATION FOR THIS SITE IS; WASHINGTON GAS LIGHT COMPANY, LOCATED AT 6801 INDUSTRIAL DRIVE SPRINGFIELD VA, 22151. N THIS MINOR SITE PLAN HAS BEEN PREPARED BY; DELASHMUTT ASSOCIATES LTD., ENGINEERS AND LAND SURVEYORS ARLINGTON, VIRGINIA delashmutf@compuserve.com 703 486-8300 v THIS MINOR SITE PLAN IS PREPARED IN CONJUNCTION W WITH SITE PLAN REVISION #0994, ENTITLED "SITE PLAN, co PROPOSED BUILDING ADDITION, SHENANDOAH GAS z CO. — KERNSTOWN", DATED DECEMBER 3, 1993, WAS ?' PREPARED BY H. BRUCE EDENS, L.S., OF GREENWAY INC. THE MINOR SITE PLAN IS INTENDED AS AN ADDENDUM ASSOCIATED WITH SITE PLAN REVISION #0994 TO IDENTIFY THE PROPOSED LOCATION OF A 30' X 26' COMPRESSOR PAD AND CANOPY. THIS PLAN DOES NOT ALTER THE, SITE DATA, SET BACK REQUIREMENTS, BUILDING HEIGHT, FLOOR AREA TO LOT AREA RATIO, PARKING SUMMARY OR THE LANDSCAPE AREA TABULATION AS SHOWN ON THE SITE PLAN REVISION #0994. APPROVED BY: ZONING AD INISTRATOR DATE SITE PLAN VALID FOR (5) YEARS FROM DATE OF ZONING ADMINISTRATOR APPROVAL. S,iincerely, ,. Mike Asnia Petroleum Facility Inspector THE ABOVE LETTER RECEIVED BY WASHINGTON GAS CO. FROM THE COMMONWEALTH OF VIRGINIA, DEPARTMENT OF ENVIRONMENTAL QUALITY IS ADDED HEREON TO VERIFY REMOVAL OF UNDERGROUND STORAGE TANKS. ACCORDING TO THE LETTER THE UNDERGROUND STORAGE TANKS WERE REMOVED AND A REPORT WAS FILED SUGGESTING THAT THERE WAS NO CONTAMINATION LEVELS FOUND THAT WARRANT FURTHER ASSESSMENT. C1 Q C W. !Robinson Electric, Inc. 14004-E Willard Rd,, Chantilly, VA 20151-2929 (703) 802-9000 FAX (703) 802-9004 July 27, 2011 Delashmutt Associates 1120 S. George Mason Dr. Arlington, Virginia 22204 Attention: Mr. Rick Bevan Project: Shenandoah Gas 350 Hillandale Lane Winchester, Virginia 22602 Subject: Canopy Lighting for Compressed Natural Gas Facility. Dear Mr. Bevan: As per our conversation today, I have reviewed Frederick County zoning section 165-201-07 (Outdoor lighting standards for nonresidential uses). I feel that we are in compliance with their requirements for the canopy lighting that is to be installed. Drawing E-1 shows the locations of the lights and they are recessed within the underside of the canopy to ensure that no light source is visible from or causes glare on adjacent properties or road rights -of way. Please do not hesitate to contact me if you need any further information. Very truly yours, C. Wayne Robinson President (Master Electrician) 0 J In W Q U 0 In In Q In Q J W O 0 0 N F- c� a_ GRAPHIC SCALE 30 0 15 30 60 ,2° Co.0�a� No.750 �+� � � S�� r!-= _ ��-T_-�-1.-�-_�.,,I _ 1;= � a,� s -�-I-�-a., �„ L�= _ a r _L T I'LT _ _ r_ L f T1� �, �,1 � � CIVIL ENGINEERS & LAND SURVEYORS 1120 S. GEORGE MASON DR. ARLINGTON, VIRGINIA 22204 (703) 486-8300 MINOR SITE PLAN SHOWING PROPOSED COMPRESSED NATURAL GAS STATION WASHINGTON GAS LIGHT COMPANY PROPERTY FORMERLY SHENANDOAH GAS COMPANY PROPERTY - KERNSTOWN S H AW N E E DISTRICT FREDERICK C 0 U N TY, VIRGINIA SCALE• 1' 30' DATE.• MAY 20, 2011 TAX MAP# FIELD BOOK. DRAWN BY. RB DRAWING: >>—�os.awc SETTINGS FILE. ( IN FEET) 1 inch = 30ft. CHECKED BY. 1 6/9/11 NEW PROPOSED COMPRESSOR PAD AND CANOPY RB JOB NO.: 11-109 FILE NO.: SHEET l OF NO. DATE DESCRIPTION BY