SITE PLAN CHECKLIST
The checklist below indicates all the information that needs to be submitted as part of the site plan
application. All required information must be submitted prior to the final approval of any site plan.
The Department of Planning and Development will review the application to ensure that it is
complete. If any portion is not included or complete, the site plan application will not be accepted
and returned to the applicant(s).
ov
-oK-
Site Plan Package
1. One set of approved comment sheets are required from the following review
a enciesprior to final site_pl;;n appl:nval It is recommen e app scants contact
the Department of Planning and Development to determine which review agencies
are relevant to their site plan application.
01319 Ste[ Virginia Department of Transportation (VDOT)
Frederick County Sanitation Authority
9'1 11" Department of Planning and Development
61-21645/ Inspections Department
V/ Frederick County Engineer (Public Works)
8 I�b h"a Frederick County Fire Marshal
Department of Parks and Recreation
2. One copy of the Site Plan application
3. Five Copies of the Final Site Plan for approval
4. One reproducible copy of the Site Plan (if required)
5. A 35mm slide of the Site Plan (if required)
V County Health Department -OK-
City of Winchester
Town of Stephens City
Town of Middletown
Airport Authority
Soil & Water Conservation District
I
t
q -795 _�Ci� aov .a��yc.�rse�i a7v 4.�ru�-f
61
U
T
1
S)2-0
1
~�. I FtlmuusttatL1 s,
COMMONWEAL iI of VIRIQIINIA
Department Of Health ROCKBRIDGE SOUARE SHOPPING CENTER
tat WALKER STREET
DIVISION OF DRINKING WATER LEXINGTON.VIRGINIA24450.2431
Lexington Environmental Engineering Field Office PHONE: (540)463.7136
FAX: (540) 463-3892
September 3, 2002
SUBJECT: Frederick County
Water — Redland United Methodist Church
Ms. Betsy Shenk
Redland United Methodist Church
P.O. Box 605
Cross Junction, Virginia 22625
Dear Nis. Shenk:
Enclosed Vou will find Commonwealth of Virginia, Department of Health, Amended Watenvorks Operation
Permit No. 2o69378 with an effective date of August 21, 2002. This permit is your authorization from the State
Health Commissioner to operate the public waterworks set- ing the Redland United Methodist Church, located
in Frederick Count\', in accordance with Part II of the WC1tC1-W07-L,; Regulations. You Will note that the permit
indicates that this water supply has a design capacity of 24,48o gallons per day. This permitted design capacity
is the maximum system capacity based on Part I I I of the Regulations and shall not be exceeded.
This amended waterworks operation permit replaces and nullifies Permit No. 2o69378 dated June 6, 1997;
therefore, it is requested that Operation Permit No. 2o69378 dated June 6, 1997 either be destroyed and this
office advised of its destruction or returned to this office.
We look forward to your continued cooperation in the maintenance and operation of this public twatenworks. If
you have any quesrions regarding this matter, do not hesitate to contact me.
Very truly yours,
Harold T. Eberle
District Engineer
I- TE/bt/02090303
cc Frederick Count\- Health Department
County of Frederick -Attn: John Riley
VDH — Richmond Central
C(2
�/DHOF HEAL RCINLA
ENT
ProkOwl You ud Your fnvrvr wv
W'MN VDH STATE VA US
SEP X q 200?
DEPT. OF PLANNING `
COMMONWEALTH OF VIRGINIA
DEPARTMENT OF HEALTH
DIVISION OF DRINKING STATER
WATERWORKS OPERATION PERMIT
TRUSTEES, I:.EDI AND UNITED METIIODIST CIIURCI-I, ARE HEREBY GRANl—ED PERMISSION TO OPERATE A NONI'RINSIENT NONCOM`IUNITY W.,*iTERWORKS
HAVING A DESIGN CAPACITY Or, 24,480 GALLONS PER DAY AT P.EDI '1ND UNITED METHODIST CI-IURCII, LOCATED IN FREDERICK COUNTY, IN ACCORD_l\Cl:
WITI I THE PROVISIONS OF TITLE 32.1, CI IAPTER 6, ARTICLE 2, SECTIONS 32.1-172 AND 173, CODE OF VIRGINI_A, AS A-NIENDED, AND 12 V:�C 5-590-260 or
THE ll,A"TF,RII7ORKS REGULATIONS OP TI-IE V11:GINIA DEPARTI'IENT OF HEALTH, AS :�14ENDED. THIS PERMIT IS ISSUED IN ACCORDANCE WITI1 PREVIOUSLY
ISSUED PERMITS: NONE (SEE ENGINEERING DESCRIPTION SHEET DATED AUGUST 21, 2002); Al\D WITH THE UNDERSTANDING THATTHE OWNER WILL
OPERATE THE WATERWORKS IN ACCORDANCE WITI I PART II, "OPERATION REGUL, 1TIONS FOR WATEI2�4'ORKS", OF TI IE WATERWORKS REGUL-1TIOVS OF TI IE
VIRGINIA DEPAR I'MENI' OF I II:ALTI I AND wl VARIANCE'S AND/OI2 EXEMPTIONS NOTED BELOW.
VAP.IANCI:S AND�OR E\L'AiP1'IONS G1:1�\TED (X) NONE () SEF A-ITACI-IED
:1�\ ENGINEERING DESCI:IP'I'ION SI IEET IS AI'I'ACI-iED DATED AUGUST 21, 2002
PERMIT NO. 206A378
EFFECTIVE. DATE•' AUGUST21, 2002
I X1)1I'.ATI0N DA
(RFV. o3/o=)
APPROVED:
DIRECTOR, DIVISION OF 111 I NG �1'ATI-R
PORTHESI'ATF.I11•:V:CIICO\I\IISS[0" U'RSUaVI1'TOVACODE..§2.2-60.1
INSTALLATION
COUNTY:
LOCATION:
OWNER:
OPERATOR:
PERMIT NO.:
DATE ISSUED:
TYPE OF TREATMENT:
SOURCE:
DESIGN BASIS:
DESCRIPTION OF SYSTEM:
STKI'E DEPAR'TM EMI' OF l-t EALTI I
ENGINEERING DESCRiP"I'ION Si-IEET
DATE: August 21, 2002
Redland United Methodist Church CERTIFIED CLASS: VI
Frederick "TYPE: Nontransient Nonconununity
On U.S. Routc 522, approximately 200 feet south of the intersection of
U.S. Route 522 and State Route 693 at Cross AInCt1O11, Virginia
Redland United Methodist Church
Redland United Methodist Church
2o69378 Amended
.June 6, 1997; August 21, 2002
Chlorination, Iron and Manganese Removal
One Drilled Well
2,1,480 GPD
The source of supply for this system consists of a drilled well, two 12o-gallon hydropneuniatic tanks,
three Zoo -gallon chlorine contact tanks, chlorination facilities, and ion exchange softening facilities.
Tile well is located approximately' 27o feet south of the church sanctuary. The well is drilled to a depth of
400 feet, cased to a depth of 105 feet with 6 25-inch steel casing, and is cement grouted to a depth Of 105
feet. The extended well casing terminates approximately 12 inches above a 6-foot by 6-foot by 6-inch
concrete slab and is equipped with a pitless adapter, sanitary seal, screened casing vent, sample tap, and
drawdown gauge. Water is pumped from the well by means of a 5 lip, 28 gpnl at 338 feet TDH
submersible pump through a flow regulating orifice plate and ion exchange Nvater softener into three
Zoo -gallon chlorine contact tanks. From the chlorine contact tanks, water enters the distribution
system. Two 12o-gallon hydropneuniatic tanks maintain system pressure and control well pump
operations. The extended well casing is unprotected while the hydropneumatic tanks, chlorine contact
tanks, water softener, chlorination equipment, and exposed discharge piping are located in the
mechanical room on the east side of the church sanetuai7•. Reported well Meld, based on a 48-hou1' Meld
and drawdown test, is 54 gpm. Total water production is metered.
Treatment facilities consist of chlorination and ion exchange softening. As water is pumped from the
well, it flows through a single, 16-inch diameter, ion exchange water softener and has a chlorine solution
injected into the softener effluent prior to entering the chlorine contact tanks. The chlorine feed system
comprises an 18 gpd at 150 psi metering pump and 35-9a11011 solution tank. The water softener has a
rated capacity of 17 gpni, an exchange capacity of 6o kilograins, and is provided N%ith influent and
effluent sample taps. Softener backwash is time clock controlled while the chlorine metering pump
operation is synchronized with the well pump.
'me design capacity for this system is based on the following data:
Source Capacity
Yield Pump Ca )aL city (Note 1)
Well No. 1 54 gpnl 17 gpm
Source capacity is limited by well pump capacity; therefore, source capacity will be 24,480 gpd (17
91)n1 x 1440 minutes/day).
Treatment Capacity
Filtration Capacity = 1 filter a 17 gpnl/filter = 24,480 gpd
Storage Capacity:
Capacity @ 200 gpd/connection = (1/3)t(240 gallons) = 1 connection
Existing: i connection
The system design capacity is storage limited; however, since this is a nontransient noncommunity water
system, excess source capacity has been substituted for storage capacity. System design capacity will,
therefore, be 24,48o gpd (17 gpnl x 1440 minutes/day).
Note is The well pump is rated at 28 gpnl; however, the well is equipped with an orifice plate flow
controller that restricts potable flow to 17 gpm.
*1/3 of a hydropneunlatic tank is considered as effective storage capacity.
I- TE/bt
COUNTY of FREDERICK
Department of Planning and Development
703/665-5651
FAX 703/678-0682
September 6, 1995
Trustees of Redland United Methodist Church
Attn: Mr. Jeff L. Cannon, Minister
P.O. Box 605
Cross Junction, VA 22625
RE: Redland United Methodist Church Site Plan Approval
Dear Mr. Cannon:
The Frederick County Planning Department administratively approved Site Plan #023-95 for
Redland United Methodist Church on September 6, 1995. The approved site plan calls for the
construction of a new church facility that is 11,800 square feet, the creation of a new asphalt
parking lot and maneuvering area that will contain curb and gutter, 77 regular parking spaces,
four disabled parking spaces that are van accessible with appropriate ramps and signage, raised
islands, parking lot lighting, and concrete sidewalks to provide access from the parking lot to
the facility, the creation of a children's play area that is protected by a chain link fence that is
four feet in height, -and all appropriate erosion and sedimentation control measures.
I have provided you with two copies of the approved site plan. This will allow you to provide
the contractor with an approved site plan to maintain on -site and to maintain an approved copy
for your records. Please contact this office to schedule an on -site inspection once all
improvements are complete. Please contact me if I may answer any questions regarding this
letter.
Sincerely,
Er, � - L? -
Evan A. Wyatt, Planner II
cc: Jimmie K. Ellington, Gainesboro District Supervisor
T. Roy Jennings, Frederick County Real Estate
Joe C. Wilder, Engineering Technician
Wayne E. Westermeyer, P.E.
107 North Kent Street P.O. Box 601
Winchester, VA 22601 Winchester, VA 22604
COUNTY OF FREDERICK, VIRSIA
DEPARTMENT OF INSPECTIONS l r
Caller JET F CAtJ")UrJ Time Called o'r'"J Date Called
Phone No. ���� ��-�� / Time Requested l�SflAP
r'tP Date Requested I A—z
Received By _Ey�ti� A - w ymTr- Date of Inspection IC3_/�� 9
PERMIT HOLDER NAME h1=i�U1rJ+� Livi TLC f �71Io�+�' +tU�C t�
RT. NO. (Q Lot No. SEC. No. SUBDIVISION
STREET NAME
DIRECTIONS �22 ���� f U� (o`i j BUILDING NO. 2_C?�
i OF (p `� I T� �N (('�� PLUMBING NO.
A- I ELECTRICAL NO.
MECHANICAL NO
SIGN NO
DISTRICT GA�i1r�
PERMIT FOR: N C ++vnCtt FI-)Q+L_Vr/ G� pP/yr2
Type of Inspection
Residential- 0-1
Footers Setbacks: FR
Commercial
M
L R
Slab
Draintile
Gas Fire -up
Final Electrical
Water
Service
Framing
Final Mechanical
/
Sewer
Rough Electric
Final v
Site Plan
Rough Plumbing
Rough Mechanical
Final Building
Fire Marshall
Groundworks
Gas Piping/Test
Final Plumbing
Special/Complaint
Other:
Time In: %"S P9 Temperature `>��� Cut in No.
Time Out: _5 7r Weather Oy -C
Results: Approvedy
Comments: 5Lk'_
Rejected
Signature � rw' ada
Date 10 / 10' Q) ("
COUNTY OF FREDERICK, VIONIA
DEPARTMENT OF INSPECTIONS
Caller 'EF CANniotii Time Called � 17- '30r,i Date Called
Phone No. ��� - �`��<<� Time Requested 9 - 30 A - Date Requested I2-9'9
Received By F_VFhJ A • \n%yffiT Date of Inspection
a 179196
7 _
PERMIT HOLDER NAME -F`EDL J> UW'n_V'�. N E_n+-b�'IS i wu'g 'fk
0
RT. NO. U a Lot No. SEC. No. SUBDIVISION
STREET NAME C20SS �UrJCTIi>`J �o/1a�
DIRECTIONS 5z2 ' C2u:�`S �r�� rior] ��rh� j' BUILDING NO. II �'Z-95
ili2rJ (� 1 2 r OtJ �-' ) L YL II1Z_PLUMBING NO
ELECTRICAL NO
MECHANICAL NO
SIGN NO
n' DISTRICT ()n'r'c5cgC't+
PERMIT FOR: }lEDv1,J� Ur,),'rEl�! M -TH-ON1.) CHvrCH
Type of Inspection
Rasi-dentfal: Cl+L>P_04 Commercial
Footers Setbacks: FIR
Slab Draintile
7:1
R
Gas Fire -up Final Electrical
Water
Service
Framing
Final Mechanical
Sewer
Rough Electric
Final +/
Site Plan
Rough Plumbing
Rough Mechanical
Final Building
Fire Marshall
Groundworks
Gas Piping/Test
Final Plumbing
Special/Complaint
Other
Time In: 9 " 3M]} Temperature
Time Out: 10 00gR � Weather _
11 70ai
Cut in No
Results: Approved F2 Ti=tr Rejected
Comments: CorotP�cTC ihrtx�P+)MP;�tI° �t2�\ ��C�V�r)P� �r�5n}Lc_
�J C
Li- ,Yrtt�Slt._I'Zl-_ /1u- �' :S �tJ2�'�L=.� ��f7f:J � Gl=hJ'l"l—
Signature w-j Date 8!z�j!��'
SITE PLAN APPLICATION
DATE 1 00t 71 M l LJ APPLICATION # �r:43 G
1. Development Name:
2. Location of Property:
(by street name)
15
Q T Jcr5e CT; 0r( o 1*ff 1
O'Cls
.6 3
3. Property Owner: �K't1STees tlCT' Ur(( Te jY94;,s1 iVf
Address: �. �Qk 6C%�
Telephone: �y� - - 33�3
4. Applicant/Agent:
e rw , %n+nlske
Address: V. ct-j
CrnsS --1unC fiofy,y0. • X'2625
Telephone: iO 3
5. Designer:
--,
Address: MOO r�aOX 6roudTot'ty
Ua _ V602
Telephone: 703 - - G (. S " 3 %Li 9
Contact:
��
JUN Pp,
RECEIV N D
DEPT. OF PLAN
AND DEMOPMENT
IL
, of
6. Is this an o iginal or revised Site Plan?
original Revised
7. Total area of parcel to be developed: • 7 lS Oc" S
8. Property Information:
a) Tax Map:
b) Parcel Number:
c)Tax ID#: A. ISM
d Current Zoning:
%
e) Present Use:
f ) Proposed Use:
p•c c, ►-.
g) Adjoining Property Zoning:
h) Adjoining Property Use: tllQ�S �CU�us0.(
i) Magisterial District: 6-0� , NS 60r
I have read the material included
what is required by the Frederick
also understand that all required
to the submission of my site plan.
Applicant's Signature:
0
in this package
County Planning
mal:will be
v
and understand
Department. I
complete prior
\J
COUNTY of FREDERICI
� J
Dcpartment of Planning, and De►•clopmcn
703 665-56:
REQUEST FOR SITE PLAN COMMENTS FAX 703 667-037
Virginia Department of Transportation
P.O. Box 278, Edinburg, Virginia 22824-0278
(703) 984-4133
The local office of the Transportation Department is located at
1550 Commerce Street, if you prefer to hand deliver this review
form.
Applicant's name, address and phone number:
Redland United Methodist Church, P.O. Box 605, Cross Junction, VA 22625 (703) 888-3373
Jeff Cannon, Minister
Name of development and/or description of the request:
We wish to construct a new church facility that would include Sanctuary, educational space, offices
C and associated space for church activities inclding fellowship dinners and other community functions
Parking and drive way access are also a part of this church relocation plan.
Location:
This property is located at the intersection of North Frederick Pike (Route 522) and Cross Junction
Road (Route 693), and is identified with PIN 19-A-1313 in the Gainesboro District.
Transportation Department Comments:
See Attached Letter To Mr. Wayne Westermeyer From W. H. Bushman
Dated 8/3/95.
VOOT Signature and Date: 46. L,i1Z Wil-►
(NOTICE TO VDOT - PLEASE RETURN THIS FORM W THE APPLICANT.)
NOTICE TO APPLICANT
It is your responsibility to complete this form as accurately as
possible in order to assist the agency with their-revs•�.,.„�
Er„—�r-
qn
please attach TF[RE copies of your plans and/or ppli'a'?k
9 Cuurt 5iluarc P.O. Box 601 W inchnicr. Virkma JUN-, 8 IM01
B �_j !AC 11 APLS
i.
CU:I,,, 7
�z
COMMONWEALTH of `yIRCjINIA
DEPARTMENT OF TRANSPORTATION
14031 OLD VALLEY PIKE
DAVID R.
P.O. BOX 278 WILLIAM H. BUSHMAN, P.E.
COMMISSIONER
RESIDENT ENGINEER GEHR
COMIONER EDINBURG, 22824-0278 TELE 17031984.5600
FAX17031984.5607
August 3, 1995
Mr. Wayne Westenmeyer, P.E.
2800 Back Mountain Road RE: Redland United Methodist Church
ri
Winchester, VA 22602 Route 522 & 693
Frederick County
Dear Mr. Westenmeyer:
We've received your revised site plans dated July 31, 1995 for the referenced project.
It appears all of our earlier review comments have been satisfactorily addressed. Please
advise the owner of our approval.
A land use permit may now be applied for to cover work within the Route 693 & 522 rights
of way. The permit will require a minimal processing fee and surety bond coverage. A
permit of this nature normally takes approximately 30 days to process and issue once
satisfactory application has been made. Therefore, I would suggest application be made
as soon as practicable.
If you have any questions or we can be of further assistance, please let me know.
RBC:br
Enclosure
cc: Mr. R. L. Moore
Mr. J. B. Diamond
Mr. S. A. Melnikoff
Mr. R. W. Watkins
Sincerely,
William H. Bushman
Trans. Resident Engineer
By: Robert B. Childress
Permits & Subdivision
Specialist Supervisor
TRANSPORTATION FOR THE 21 ST CENTURY
COMMONWEALTH ®f VIIRQINIA
DEPARTMENT OF TRANSPORTATION
14031 OLD VALLEY PIKE
DAVID R. GEHR P.O. BOX 278
COMMISSIONER EDINBURG, 22824-0278
July 7, 1995
Mr. Wayne Westenmeyer, P.E.
2800 Back Mountain Road
Winchester, VA 22602
WILLIAM H. BUSHMAN, P.E.
RESIDENT ENGINEER
TELEi7031984 5600
FAA17031984 5607
Ref: Redland United Methodist Church
Routes 522 & 693
: � e-C.^.. %-C..nty
Dear Mr. Westermeyer:
As requested, we have reviewed the referenced pro*ect's site plan dated June 7, 1995. Our comments
may be found on the enclosed plans marked in red and as follows:
1.) The entrance width on Route 693 will need to be increased to a minimum 30'.
2.) The.half typical section of the proposed entrance with pavement design noted will need to be
incorporated into the plan. Also, there is some confusion over the pavement design for the
access roadway shown on Sheet 5-C.
3.) To improve the life of the entrance culvert, we suggest it be asphalt coated. Also the ends of
the pipe should be mitered to conform to the fill slope.
4.) The drainage calculations provided indicated that Culvert No. 3 is to be installed under the
Route 522 entrance. However, no entrance is shown within the Route 522 right-of-way.
5.) During earlier discussions you indicated additional grading on the Route 522 right-of-way may
be desirable to eliminate existing tractor trailer parking in front of the church property. If the
church still intends to do so, this grading will need to be shown on the plan.
6.) Other miscellaneous items as marked will need to be addressed.
Please revise and resubmit six (6) copies for final approval. Should any changes be deemed
necessary, please design them to meet or exceed the above recommendations.
If you have any questions, please let me know.
Sincerely,
Q� 06. a-4-P'C ,a._-
Robert B. Childress 0213��j�®
Trans. PermitsCO*
& Subdivision � 4
Specialist Supervisor C JUL IS95
LO
RBC/rf � RECOVED
Enclosure N AEPT. OF PLANNING
xc: Mr. J. B. Diamond, Attn: Mr. K. B. Downs
6 DEVELOPMENT
Mr. S. A. Melnikoff, Mr. R. W. Watkins n� „�1c�
TRANSPORTATION FOR THE 21 ST CENTURY
�k�
'Cyr
COMMONWEALTH of VIRQINIA
DEPARTMENT OF TRANSPORTATION
14031 OLD VALLEY PIKE
DAVID R. GEHR PO BOX 278 WILLIAM H. BUSHMAN, P.E.
COMMISSIONER EDINBURG, 22824-0278
RESIDENT ENGINEER
TEL-17031984.5600
F4X,703r984 5607
June 26, 1995
Mr. Kevin R. Firebaugh Ref: Redland United Methodist Church
C/O Redland United Methodist Church Routes 522 North & 693
304 Lakeview Drive Frederick County
Cross Junction, VA 22625
Dear Kevin:
In accordance with your request of June 2, 1995 you are given permission to install a temporary
construction entrance at the reference location. This letter is to be considered your permit to do so. The
following provisions will be required:
Work area protection signage in accordance with the attached while working on the right-of-way will
be required.
All work on the right-of-way is to be confined to the temporary entrance location only.
A minimum 6" depth of VDOT #1 (2-3 inch stone) course aggregate by 30' in width will be required.
It is to be placed from the edge of pavement and extended back onto private property far enough to
prevent the carrying of mud onto the roadway.
Positive drainage is to be maintained within the right-of-way at all times.
Any disturbed areas of the right-of-way or damages to the pavement structure adjacent to this entrance
will be repaired by you to our satisfaction.
This permit is being issued for 180 ,la.,s. Aland use perr_r.it must be applied for within the allotted tiz-ac.
All work is to be completed in accordance with the enclosed Virginia Erosion & Sediment Control
Handbook, Specification 3.02.
The Department of Transportation will not be held liable for suit should such result from this operation nor
is it granting permission to grade on the property of others or disturb underground utility lines. If the above
listed items are not followed this permit may be revoked. �,y
Should you have any questions, please let me know.
Sincerely,
Robert B. Childress
Permits & Subd. Spec. Supervisor
RB C/rf
Attach.
xc. Mr. D. A. Heironimus, Mr. S.TA. McIRTATOIOff N r rRHEW, at
ins Mr. H. E. Strawsnyder
1
N �I
COMMONWEAL L T � I of VII3CINIA
DEPARTMENT OF TRANSPORTATION
14031 OLD VALLEY PIKE
DAVID R. GEHR PO BOX 278 WILLIAM H. BUSHMAN. P E.
CCMMISSIONEH EDINBURG. 22824-0278
RESIDENT ENGINEER
June 26, 1995 TELE17031984 560
FaX 1703^ 984 5607
Mr. Wayne Westenmeyer, P.E. Ref: Redland United Methodist Church
2800 Back Mountain Road Routes 522 & 693
Winchester, VA 22602 Frederick County
Dear Mr. Westenmeyer:
We have received your site plans dated June 7, 1995 for the referenced project. We have
forwarded the plan to our District Office in Staunton for review. Once we receive any
comments we will forward same to you. For your information our review time for a project
of this nature is approximately sixty days.
If you have any questions, please let me know.
RBC/rf
xc: Mr. S. A. Melnikoff
Mr. R. W. Watkins
Sincerely,
William H. Bushman
Trans. Resident Engineer
By: Robert B. Childress
Trans. Permits & Subdivision
Specialist Supervisor
TRANSPORTATION FOR THE 21 ST CENTURY
Request For Site Plan Comments
Department of Planning and Development
Mail to: Hand deliver to:
Department of Planning and Development 107 N. Kent Street
Atten: County Planner Fourth Floor
P.O. Box 601 Winchester, VA
Winchester, VA 22604 (703) 665-5651
(703) 665 - 5651
Please fill out the information as accurately as possible in order to assist the agency
with their review. Please attach two copies of your site plan with this sheet.
Applicant's name: N/AYN41L �Wil SM TEM Y-;g,
Address: Z800 prC—K M 14 ROAD
WI NCHCm%r-e— Vik 2-24-02—
Phone number: 18%%— 1343l
Name of development and/or description of the request: EW R oL-^miD U ML
Gtoss JumcnotJ 1
U
Planning an�eveloprnent use only Z
Date received" �1 Date revision received 8 t 195 Date approved ! 14
Incomplete
Date reviewed 15'
ignature and Date
Signature and Date (revision
M-,.;j My %,,Lz :
Incomplete
Date reviewed
X
0 •
�s
COUNTY of FREDERICK
- -- Department of Planning and Development
703/665-5651
FAX TRANSMITTAL PAGE FAX 703/678-0682
DATE: ,%Ws USt 7. 1995 TRANSMITTAL TIME:
PLEASE DELIVER PAGE(S) EWAEDIATELY TO:- --
NAME: Mr. Wayne Westenmeyer
COMPANY:
CITY, STATE: Winchester, VA
FAX NUMBER: 665-3621
RE: Redland United Methodist Church Site Plan
TOTAL NUMBER OF PAGES INCLUDING THIS COVER PAGE: -2-
MESSAGE:
It is not necessary for you to resubmit plans for review unless
you would like to do so. Please contact me if you have any
questions regarding this information.
FROM: Evan A. Wyatt
TITLE: Planner II
FREDERICK COUNTY PLANNING DEPARTMENT
PHONE: (703) 665-5651
FAX NUMBER: (703) 678-0682
107 North Kcnt Strcet
Winchester, VA 22601
P.O. Box 601
Winchester, VA 22604
9 6
COUNTY of FREDERICK
Department of Planning and Development
703 / 665-565 l
FAX 703/678-0682
August 7, 1995
Wayne Westenmeyer
2800 Back Mountain Road
Winchester, VA 22602
RE: Revised Site Plan Review of Redland United Methodist Church
Dear Mr. Westenmeyer:
I have had an opportunity to review the above referenced site plan, received by our department
on August 1, 1995. The majority of the comments from my June 26, 1995 review have been
addressed; however, there are a few minor comments that need to be addressed to satisfy the
requirements of the Planning Department. Please include the following information on this site
plan:
1) Please revise the signature block to read Zoning Administrator. (Sheet C-1)
2) Please revise the information provided under #5 of the General Notes to remove 19-A-
13A, as this parcel has been consolidated into parcel 19-A-13B. (Sheet C-1)
3) Please revise the parcel boundary information on sheet C-2 and sheet C-3 to remove the
boundary line and note that were incorporated during the consolidation of the two
properties. Thank you for providing our department a copy of the approved, recorded
consolidation plat.
4) In conjunction with comment number 3, please also remove the notes of sheet C-2 and
sheet C-3 that read "Parcel A" and "Parcel B".
5) Please provide a description of ]low the outdoor trash area will be enclosed.
6) Please provide the name Cross Junction Road for Route 693. (Sheets C-2 & C-3)
Please provide our department with approved review agency comment sheets from the agencies
specified in my June 26, 1995, and five copies of the final site plan that address the comments
specified in this letter. I will recommend final approval of your site plan once this information
has been received. Please contact me if I may answer any questions regarding this letter.
Sincerely,
Evan A. Wyatt, P U nner II
cc: Jeffery Lee Cannon, Minister
107 North Kent Street P.O. Box 601
Winchester, VA 22601 Winchester, VA 22604
IL\
Wayne Westermeyer P.E.
2800 Back Mountain rd..
Winchester, VA 22602
31 July 1995
Mr. Evan A Wyatt
Department of Planning and Development
107 North Kent Street
Winchester, VA 22601
RE: Site Plan Review of Redland United Methodist Church
Dear Mr. Wyatt:
I have incorporated the comments that your office has made on the Preliminary Site Plan, and I
am resubmitting them for final approval. Following is a brief description of how each comment
was addressed.
1) The phone number for the owner/developer was included with his address on sheet C-1.
2) All spelling and spacing errors have been corrected as noted on sheet C-1.
3) The USGS Gore Quadrangle Map on sheet C-1 has been labeled as the Location Map.
4) The adjoining property information has been changed to the names that were recorded on
the consolidation plat dated 7/17/95. This information I believe is current.
5) A copy of the recorded consolidated plat is attached to this letter.
6) The only area specifically designated for recreation is the children's play area noted on
sheet C-3. A fence has been added to increase safety for the children.
7) The only outdoor storage area included in this project will be for the trash receptacles.
This area has been added and designated on sheet C-3.
8) See comment number 7 above.
9) A detail of the lighting fixture has been added to sheet C-5.
10) The names of the adjoining roads have been added to both sheets C-2, and C-3.
11) The speed limit of 55 mph has been added to the State Route 522 designation. The speed
limit on the Cross Junction Road (St. Rt. 693) is not posted.
•
12) Location of easements have been designated where required on sheet C-2.
13) The slopes of the proposed disabled parking spaces have been changed to a maximum of
2%. Grading has been adjusted to allow for this change.
14) The only landscape plantings in the project will be the reseeding of the area with grass.
In addition to your comments I have also incorporated other agencies comments that are reflected
in these drawings. Once these offices have given final approval to the site plan I will provide
your office with a copy of their approved agency comment sheets.
If you have any further questions please contact me (703)877-1389. I would like to thank you
for your help in this matter and look forward to working with your office in the future.
Sincerely,
Wayne E. Westenmeyer P.E.
enclosures: Copy of consolidation deed
Set of site plan drawings C-1 thru C-5
QK8iYyf;nnn2
��9
Q,/i�clr
,ar?'+, ,\ (D In
693
Ilion CROSS
\
— --..
v'(rr A In
MEAMA
Ill
/ l (l—
l
MM �1
.� ;. nc
.7
ItI
'
Cold L�
St
E
lak Ilulida'
,1 � IIIAiI
.Slu'1n1; �_ c•
14CAIIITY MAP \\
_
41,
!!
.. SCAIE; 1`-2000'
1
APPR0VI;'D f1Y
Subdivision Administrator e-7/1
0 YNERS' CONSENT
The above and foregoing Lot Consolidation of the land of TRUSTEES OF T11E
RFDLAND UNIIEO MFT710DIST C1lURCII, as appears In the occompon)�ng plat, is with the
free consent and in acaordance with the desire) of the undersigned owners, proprietors,
-
and trustees, if ony. 1 1,1171
:\' 7*-_ram' i. r•l. T _ _ -
�_ /
i
NOTARY PUBLIC
1 Janet D. Lowery , a Notary Public In and for the state of Wirginia,
at large, do certify that _ George B. Whitacre,_5.. ustees
of Redland United Methodist Church
whose names are signed to the foregoing Owners' Consent, have acknowledged the
same before me In my state.
Given tinder my hand this 13th day of 7_U- _' 1995.
My commission expires 9-30-96
Notary PeTwil
\\ JJ
S(7RV sYOR'S CERTIFICATE
l hereby certify that the land contolned In this Lot Consolidation Is the some land
"A" "B" which were conve),Ld to TRUSTEES OF THE REDI_ANO
designated as Parcels and
UNITt-D MET110DIST CHURC11 by deeds dated 12 March 199.3 and recorded In the Office of
the Clerk of the Circuit Court of Frederick County, Virginia in Deed Book 793 at Page 764
and Deed Book 79,3 at Page 766, respectively_ )
' Dou I 's C. Legge, L.S.
TY 19 ((A)) Pcl 13A
Zoned: RA
Current Use: Vacant FINAL PLA T
Proposed Use: Church for
TM 19 ((A)) Pc1 138 L O T CONSOLI DA 77ON
Zoned: RA of the land of
Current Use: Vacant
Proposed Use: Church TRII,S'T sES OF THE
R;nLAND IINITF,D 11fE7'IIOnIST CIIrI12C,II
rr�P�711
�'
trl'E
;Sf Colnesboro Magisterial District
it
Frederick County, Vrginio
CERTIFICATE (1. DAH: 12 July 1995 Cover Sheet Sheet 1 of 2
N
L) 1197 MARSH- & ILEGGE
Land Surveyors, P.L.C.
I111
(�
en S¢ Wtncluater, VUVinta 22601
l FI l 139 North C_ammuet
703 667-046B Fox (70J) 667-0469
4. • 10
VA. SEC. R7'F,. 693
DES JUNCTION ROAD
N 0400'25"
90.65'
N 1.5 0530"
101.30'
UK8421f*00003
AREA SUMMARY
Parcel 13A 1.0168 Acres
Parcel 138 11.7778 Acres
Total Arco 12.7946 Acres (To Become Parcel 138)
224, 7. `J
a ^ yam
00
tiv . �• ° ,�
Q b
N 0729'00" t
315.42'
Lj. \
N 0729'00" 11/'1
84.79'
1 1
0
I. 1
LEGEND
IRF Iron Rod Found
HON Highway Afonument Found
%
Trustees For Redland\ \
United Methodist Church
z AM 1,9.7946 Acres \
TAr 19 ((A)) PCf, 139 /
ZE
I
�%K
to' 6RL
AlQV RF tY t��'c�
S 8820 27 fU 380.90'f
� I �
'b
txi
NO7ES:
1, No title report furnished.
2. Easements may exlst that are not shown.
J. Iron rods found or set at all property corners.
4. Rounflory information shown on thls plot taken
from plot of record dated 14 November 1992
drawn by 7Momos A. Shockey, L.S., and recorded
in Deed Rook 790 at page 718 in the Frederick
County, lrirginlo Clerk's Office.
TAI 19 ((A)) Pcl 13A
Zoned. RA
Current Use: Vacant
Proposed Ilse: Church
TAt 19 ((A)) Pcl 1,38
Zoned: RA
Current Ilse: Vacant
Proposed Use: Church
SS � fY /I
❑ CERTIf ICATE til-I.
v 1197
DATE:
!RF
HINIHIJAI SETBACK REQUIREHENTS:
Fron t = 60'
Rear = 100'
Side = 100'
GrophIc Scale In Feet
FINAL PLAT
fo-t-
LOT CONSOLIDA TION
. of the .land of
TRUSTEES ES Or, THE
P sDIAND UNITED METHODIST CIIURCII
12 July 1995
Gainesboro Magisterial District
Frederick Count}; Virginia
Plot: PC-9407.dwg I Sheet 2 of 2 - ^I
VIRGINIA: FREDERICK COUNTY, SCT.
Mi This instrument ofjwriti g wps pru cQd
I. to me tithe _lWY
173 Pdcxth Ame T(7J)
66x- 190. at_L' �tof acknowledgmWit tlwannexed was
•
•
•
COUNTY of FREDERICK
Department of Planning and Development
703 665-5651
FAX TRANSMITTAL PAGE FAX 703 f 678-0682
DATE: ,Tune 26, 1995 TRANSMITTAL TIME:
PLEASE DELIVER PAGE(S) IMMEDIATELY TO:
NAME: Mr. Wayne Westenmeyer
COMPANY:
CITY, STATE: Winchester, Virginia
FAX NUMBER: 665-3621
RE: Redland United Methodist Church Site Plan
TOTAL NUMBER OF PAGES INCLUDING THIS COVER PAGE: -3-
MESSAGE:
Please contact me if you have any questions.
FROM: Evan A. Wyatt
TITLE: Planner 11
FREDERICK COUNTY PLANNING DEP. WFNIEN'T
PHONE: (703) 665-5651
FAX NUMBER: (703) 678-0682
107 North Kent Street P.O. Box 601
Winchester, VA 22601 Winchester, VA 22604
•
•
June 26, 1995
Wayne Westenmeyer
2800 Back Mountain Road
Winchester, VA 22602
COUNTY of FREDERICK
Department of Planning and Development
703/665-5651
FAX 703/678-0682
RE: Preliminary Site Plan Review of Redland United Methodist Church
Dear Mr. Westenmeyer:
I have had an opportunity to review the above referenced site plan, received by our department
on June 8, 1995. The following comments need to be addressed prior to final approval of this
site plan:
1) Please provide the telephone number for the owner and the developer. (Sheet C-1)
2) Please revise the information provided under General Notes as indicated on the marked -
up site plan. (Sheet C-1)
3) Please label the section of the USGS Gore Quadrangle Map as the Location Map. (Sheet
C-1)
4) Please revise the adjoining property information for the property identified as 19-A-13.
The current tax role information indicates that this property is owned by Alan D.
Bloomingdale. (Sheet C-2)
5) The metes and bounds description indicates that the two parcels will be consolidated.
Please provide our department with a copy of the approved, recorded consolidation plat.
6) Please provide the location of any proposed recreational facilities for this site.
7) Please provide the location and description of any proposed outdoor storage area for this
site.
8) Please provide the location of any proposed outdoor dumpster area and the specifications
for enclosing this area.
9) Please provide the height and design specifications for the proposed outdoor lighting
fixtures. (Sheet C-4)
10) Please provide the name and number for the existing roads that adjoin this site: State
Route 522 North Frederick Pike, and Old Route 522 Cross Junction Road. (Sheets C-2
& C-3)
11) Please provide the posted speed limits for these roads, and the location of any existing
entrance within 200 feet of the proposed entrance. (Sheet C-2)
12) Please provide the location and description of any easements that are located on this site
or that adjoin this site.
107 North Kent Street P.O. Box 601
Winchester, VA 22601 Winchester, VA 22604
•
0
Page -2-
Westenmeyer Letter
June 26, 1995
13) Please ensure that the proposed disabled parking spaces meet the maximum slope
requirement. (Sheet C-3) You should contact John Trenary, Building Official to verify
this requirement.
14) Please provide the location and type of any proposed plantings for this site. I will be
glad to provide input regarding the planting selection as it relates to this part of the
county.
Please provide our department with approved review agency comment sheets from the Virginia
Department of Transportation, the Frederick County Inspections Department, the Frederick
County Engineer, the Frederick County Fire Marshal, and the Health Department, and five
copies of the final site plan that address the comments specified in this letter. I will recommend
final approval of your site plan once this information has been received. Please contact me if
I may answer any questions regarding this letter.
Sincerely,
Er, �.
Evan A. Wyatt
Planner II
EA W
enclosure
cc: Jeffery Lee Cannon, Minister
•
n
SITE PLAN CHECKLIST
The checklist below indicates all the information that needs to be submitted as part of the site plan
application. All required information must be submitted prior to the final approval of any site plan.
The Department of Planning and Development will review the application to ensure that it is
complete. If any portion is not included or complete, the site plan application will not be accepted
and returned to the applicant(s).
Site Plan Package
1. One set of approved comment sheets are required from the following review
agencies prior to final site >alan aoproval It is recommended that applicants contact
the Department of Planning and Development to determine which review agencies
are relevant to their site plan application.
Virginia Department of Transportation (VDOT)
Frederick County Sanitation Authority
VDepartment of Planning and Development
Inspections Department
�L Frederick County Engineer (Public Works)
�L Frederick County Fire Marshal
Department of Parks and Recreation
2. One copy of the Site Plan application
3. Five Copies of the Final Site Plan for approval
4. One reproducible copy of the Site Plan (if required)
5. A 35mm slide of the Site Plan (if required)
County Health Department
City of Winchester
Town of Stephens City
Town of Middletown
Airport Authority
Soil & Water Conservation District
8
Site Plan Information Checklist
The following information must be included on your site plan. If your site plan is incomplete or
is missing information, it will not be reviewed and returned to you for revisions.
Administrative Information
Y N
1.
Name of proposed development.
GName,
address, and phones Pr of owner.
Name, address, and phone number of developer.
4.
Name, address, and phone number of designer.
5.
Certificate of surveyor, engineer, or architect.
6.
Date plan prepared and date of revisions.
7.
A listing of all conditions placed on the site as a result of a
conditional use permit or conditional zoning approval.
8.
A space labeled "Approved by the Zoning Administrator' for
the approval signature and date of approval.
9.
A description of setbacks or conditions placed on the site as a
result of a variance approval. (Reference the variance
application number.)
General Site Information
Y N
GLocation
map (scale 1:2000)
11.
Magisterial District
12.
Scale of site plan (not to exceed 1:50)
13.
North Arrow
14.
Zoning of site
Use, zoning, and Property Identification Number (PIN#) of all
adjoining properties. This includes properties located across
right-of-ways, streams, and railroad tracks.
OSurveyed
boundaries for all lots and parcels.
9
E
•
General Site (con't)
Y N
Building Information
Y N
Roads
Y N
17
18
19.
0
21.
22.
23.
25
6
Acreage of all lots included in the plan.
The location and dimensions of all required setbacks and yard
areas.
The location and type of all dwelling units. FVru2E r*WT-S4%*SE�
Location and description of all recreation facilities.
Location of sidewalks and pedestrian ways.
Location and area of common open space.
The location, height, and dimensions of all signs.
Location, hem and specifications of outdoor lighting fixtures.
Location and nature of outdoor storage areas.
Location of outdoor trash receptacles and dimensions of
structure (fencing, etc.) required to enclose receptacles.
27. The height of all buildings and structures.
28. Location of all buildings, structures and uses.
29. The proposed use of each building, structure and area.
30. Ground floor area and total floor area of all buildings with FAR
calculations for commercial and industrial zoning districts.
31 Name and number of existing and planned streets on and
adjoining the site.
32. Location of existing and planned streets on and adjoining the
site.
33 Posted speed limit of existing adjacent roads.
4 Location and dimensions of all proposed entrances from public
right-of-ways.
TO 6 E APP¢ovED GY V Dar —
a
• 0
f
535�,,
Location of all entrances on adjoining roads within 200 feet of the
proposed or existing entrance.
36.
Dimensions, boundaries, width, pavement, and construction of
planned roads. �ACCXSS 200',
Utilities
Y N
TH brLfMtT-MO�
37
Location of all utilities, including sewer and water lines with the
size of lines, mains, and laterals.
_ /
38
Location and width of all easements, including access, utility,
and drainage easements.
Location and nature of fire lanes, fire hydrants, and all other
t
facilities necessary to meet Fire Code requirements.
To 8 E Awaa�� 131 Fs
<.q
Parking
Y N
40. Calculations describing the required number of parking and
loading spaces.
y� 41. Location and dimensions of all parking and loading spaces,
driveways, parking aisles, curbing and other features to be used
42 Location and dimension of all disabled parking spaces and
ramps.
t3tjIL-D#rI6 0FPICiA-%- 'To IrL714SUILC
Natural Features ArD^ C.0hfIL-ta+JaC-
Y N
43. Existing and finished contour lines.
Location of steep slopes. woodlands floodplains, wetlands,
sinkholes, and other environmental features.
45. Location of streams and drainage ways
• 0
Landscaping
Y N
�� 46 Landscaping plan descnbing location and types of plants to be
used.
47. Location of required buffers and screening with cross sections or
profiles.
Erosion and Sediment Control
Y N
4 A stormwater management plan with run off calculations and
location and description of facilities to be used.
4 Soil erosion and sedimentation control plan descnbing the
location and methods to be used to minimize erosion and
sedimentation during development.
Tc 6E A{P2DvED By C a U N1.-Y
12
COUNTY of FREDERICK
Dcpartment of Planning and De\elopmen-
703 665-56`4
REQUEST FOR SITE PLAN COMMENTS FAX 7113 667-117c
Frederick County Inspections Department
P.O. Box 601, Winchester, Virginia 22601
(703) 665-5651
The Frederick County Inspections Department is located at 9 Court
Square in Winchester, if you prefer to hand deliver this review
form.
Applicant's name, address and phone number:
Redland United Methodist Church, P.O. Box 605, Cross Junction, VA 22625 (703) 888-3373
Jeff Cannon, Minister
Name of development and/or description of the request:
We wish_to construct a new church facility that would include Sanctuary, educational space, offices
( and associated space for church activities inclding fellowship dinners and other community functions.
l- Parking and drive way access are also a part of this church relocation plan.
Location:
This Drorlertv is located at the intersection of North Frederick Pike (Route 522) and Cross Junction
Road (Route 693), and is identified with PIN 19-A-13B in the Gainesboro District.'
Inspections Department Comments:
Comments are on the back of this sheet.
Inspect. Signature & Date:
(NOTICE TO INSPECTIONS - PLEASE RETURN THIS FORld TO/APPLICANT.) ✓ \
NOTICE TO APPLICANT
It is your responsibility to complete this form as accurately as
possible in -rder to assist .he agency with their review. Also,
please attach a copy of your plans and/or application form.
9 courl SQIJarc - P 0. dp\ 6U1 \Vinchesi r. Virvoij - _2601
• 0
Inspections Department's Comments
Building shall comply with Virginia Uniform Statewide Building Code and
Section 303 & 305, Use Group A (Assembly) and E (Educational) of the BOCA
National Building Code/1993. Other codes that apply (to Educational Area Only)
are title 24 Code of Federal Regulation, Part 36 Nondiscrimination on the Basis
of Disability by Public Accommodations and in Commercial Facilities. A/E sealed
plans required on building and systems plans. ADA parking and access to building
appears ok. NOTE: Max. 2% grade across ADA parking and unloading area. NOTE:
Table 313.1.2 for fire separation between Use Groups A-4 and E.
•
COUNTY of FREI)ERICK
Public Works Department
Harvey E. Strawsnvder, Jr., P.E.
Director
Svc
183/665-5643
Fax: 3,83/678-0682
$YO
July 5, 1995
Mr. Jeff Cannon
Redland United Methodist Church
P.O. Box 605
Cross Junction, Virginia 22625
RE: Site Plan Review for Redland United Methodist Church
Dear Jeff:
The design documents prepared by Lewis and Associates adequately
addressed our concerns related to stormwater management and erosion
and sediment control. Consequently, we granted a land disturbance
permit based on the implementation of these documents.
However, after reviewing the plans prepared by Wayne
Westenmeyer, we offer the following comments:
1. The culvert designs and locations should be coordinated with
the design recommended by Lewis & Associates. i.e. Lewis
recommended an 18" RCP.
2. Refer to sheet C-3: The grading approved for the Lewis
design should be reflected on the Westenmeyer design.
3. Refer to Sheet C-5: The proposed pavement details appear to
be somewhat conservative for the anticipated church traffic.
We suggest that John Lewis evaluate these designs to
determine more realistic and cost effective alternatives.
This evaluation should also, be extended to a review of the
sidewalk details.
�J,
V
JUL 1995
RECEIVED
A DEFT. OF PLANNING
r_ (NO DEVELOPMENT
107 North Kent Strcct P.O. Box 601
Winchester, VA 22601 Winchester, VA 22604
CI
n
LJ
Cannon Letter
July 6, 1995
Page 2
Please have the designers make the appropriate revisions and resubmit
the revised drawings for our review. After reviewing the revised
drawings, we will provide you with an approval letter assuming that
sheet C-3 has been appropriately revised to reflect the grading
scheme shown on the approved erosion and sediment control plan.
Sincerely,
Harvey Strawsnyder, Jr., E.
Director of Public Works
HES:rls
cc: Evan Wyatt, Planning & Zoning
John Lewis, Lewis & Associates
Wayne Westenmeyer
file
•
COUNTY OF FREDERICK, VIRGINIA
FIRE MARSHAL'S OFFICE
LAND DEVELOPMENT COMMENTS
Control No. 0629952554 Date Received 080895 Date Reviewed 081695
Applicant Waynne Westenmeyer P.E.
Address 2800 Back Mountain Rd.
Winchester, Va.
22602
Project Name Redland United Methodist Church Phone No. 540-888-3373
Type of Application Revised Site Plan Current Zoning RA
1st Due Fire Co. 16 1st Due Rescue Co. 16 Election DistrictGainesboro
Tax I.D. No. 19-A-13A
RECOMMENDATIONS
Automatic Sprinkler System Residential Sprinkler System
Automatic Fire :alarm System XX Other
REQUIREMENTS
Emergency Vehicle Access
Adequate XX Inadequate Not Identified
Fire Lanes Required Yes XX No
Comments Posted Fire Lanes required at building on south side for Fire Dept.
Access
Roadway/Aisleway Widths Adequate XX Inadequate Not Identified_
Special Hazards Noted Yes No XX
Comments
Hydrand Locations Adequate Inadequate Not IdentifiedXX
Siamese Location Adequate Inadequate Not Identified XX
Additional Comments Attached? Yes No XX
Plan Approval Recommended? Yes XX No
Signattar _ ' Title -« a __
•
I�
Mr. Wayne Westenmeyer
Enviromental Engineer
U.S.A. Corps of Engineers, Transatlantic Division
P. O. Box 2250
Winchester, Virginia 22604-1450
Dear Mr. Westenmeyer,
I've reviewed the changes to the Fire Lane configuration for Redland United Methodist
Church which you faxed to my office on 7/7/95. This design allows much better access
for Fire Dept. vehicles should the need ever arise to deploy a ladder truck to this
building.
Thank you for your efforts to make this site as accessible as possible for emergency
vehicles. We all hope our services are never required in an emergency situation, but
when they are, it is to everyones benefit to have a site that allows immedeate access to
all portions of the structure, including the roof.
I will be looking for the revised site plan in the near future so that final approval from the
Zoning Administrator can be obtained and your project can move forward. If there is
anything further my office can assist you with, please do not hesitate to contact us.
Sin ely,
Douglas A. Kiracofe
Fire Marshal
cc: Jeff Cannon, Redland U.M.C.
Even Wyatt, Planning Dept.
File
•
COUNTY OF FREDERICK, VIRGINIA
FIRE AND RESCUE DEPARTMENT
9 N. Loudoun Street, 2nd Floor
Winchester, Virginia 22601
Thomas W. Owens
Director
June 29, 1995
Redland United Methodist Church
P.O. Box 605
Cross Junction, VA 22625
Attn: Jeff Cannon
Dear Mr. Cannon,
Douglas A. Kiracofe
Fire Marshal
I have reviewed the site plan submitted for the new church
building to be located on Rt. 522 N. (North Frederick Pike). The
plan, as drawn, cannot be approved by the Fire and Rescue Dept. as
there is inadequate access to the north and south sides of the
building for a ladder truck.
When we met on April 26, 1995 to discuss your variance request
for height, there was agreement that automatic smoke ventilation
devices would be placed in the gable ends of the structure, and access
for a ladder truck on three sides of the structure. As shown, the
fire lanes are 100' from the building which exceeds the capabilities
of our truck.
In order to utilize our aerial device effectively, the centerline
of the fire lane must be a minimum of 20' and a maximum of 35, from
the face of the building.
If your parking configuration is to remain as shown, additional
fire lanes will be necessary for fire dept. use, constructed to
specifications for fire lanes, found in Frederick County Ordinance
Chapter 10. Basically this would require fire lanes 20, in width,
capable of supporting 60,000 pounds and posted with signage
designating the fire lane as a "No Parking" area.
Please do not hesitate to call me if there are any questions on
this matter.
inc el ,
Douglas A. Kiracofe
Fire Marshal
CC: Chief Larry Light: Gainesboro Vol. Fire & Rescue
Evan Wyatt: Planning Dept.
File
DIRECTOR - (703) 665-5618 FIRE MARSHAL - (703) 665-6350 FAX - (703) 678-0682
COUNTY OF FREDER:CK, VIRGINIA
FIRE MARSHAL'S OFFICE
LAND DEVELOPMENT COMMENTS
Control No. 0609952554 Date Received 060995 Daze Reviewed
Applicant Name Jeff. Cannon, Minister
Address P.O. Rcx 605
Cross Junction, VA 22655
Project Name Redland Un'-.d Methodist Church
Phone No. 17w )88R-1373
Type of
Application
.51TE ,Z, X/
Current Zoning
Ist Due
Fire Co. /-
1st
Due Rescue Co.
AS
Election District
RECOMMENDATIONS
Automatic Sprinkler System X Residential SprV=kler System
Automatic Fire Alarm System Jr Other
Emergency Vehicle Access;
Aaequate Inadequate �_ Not Identified _
Fire Lanes Required; Yes �_ No
Comments:
Roadway/Aisleway Widths;
Adaquata_ Inadequace
Special Hazards .Noted; Yes
Comments:
No c Ident i F ted
Nc_
- Cc n t : nuec -
9
0
Hydrant Locations;
Adequate
Inadequate Not ldentifiad x
Siamese Connection Location;
Aporoved Not Approved Not Identified
Additional Comments:
Douglas A. Kiracofe
Fire Marshal
Date: I/W95 Time: oiIIII6
from: Jeff Cannon To: Mk. Stephel �3 4 T_ G_ P A I N T E E
�,Ci1.fC— 1, 4 mci i
age 1ofL
p . 0 1
R ues r it Plan Com ents me
Frg sic n - in esterHealth e
ai
Fredeiftk-Winchester st rins®nth Department
Atten: Sartitatlo 6
P.O. Box 2066
Winchester, VA 22604
703) 665.3480
possibleccuratelY SS in order to assist the a$AnCY
Ptease fill out the in1•art cr,
or ta copy of your site plan with this sheet,
with their review. P
gpplicSnt'a name; Redland United Me ho
Address:
Phone number.
Name of development and/or description of the fequest
A New church wit a
B00 SmitnTle
Winchester,
(703) 665-3
n f develo ment,' ,, —
At the Intersection of�Rt,2and Old Rt. 5 2 i
4
Health Dept,'S Comments.
Ln
vL
_ 1h n i t.
3atth 0ept:` antY Date a
0��`r�
V�I
,j0LJ--"',Y,
it
SFP ,99
� S
cCb
���E
N Win 0
fah DeD/ ester