HomeMy WebLinkAbout52-96 Negley Mini-Storage - ERL - Stonewall - Backfile (2)SITE PLAN CHECKLIST
The checklist below indicates all the information that needs to be submitted as part of the site plan
application. All required information must be submitted prior to the final approval of any site plan.
The Department of Planning and Development will review the application to ensure that it is complete.
If any portion is not included or complete, the site plan application will not be accepted and retumed
to the applicant(s).
Site Plan Package
1. One set of approved comment sheets are required from the following review
agencies prior to final site plan approval. It is recommended that applicants contact
the Department of Planning and Development to determine which review agencies
are relevant to their site plan application.
Virginia Department of Transportation (VOOT)
Frederick County Sanitation Authority
Department of Planning and Development
Inspections Department
Frederick County Engineer (Pudic Works)
Frederick County Fire Marsnal
Department of Parks and Recreation
2. One copy of the Site Plan application
3. Five Copies of the Final Site Plan for approval
4. One reproducible copy of the Site Plan (if required)
5. A 35mm slide of the Site Plan (if required)
County Health Department
City of Winchester
Town of Stephens City
Town of Middletown
Airport Authority
Soil & Water Conservation District
/-/3- 97
l• l3 47
0
CASH
RECEIPT
M
Received From _
V
Address
^
r
For
n'
AMT OF
ACCOUNT
AMT PAID
AN( i
Datef lJ C�1 �l 19 1 0 0 2 510 7
CASH
CHECK
MONEY
ORDER
✓yAty-6 fi y Dollars $.
c-ie r
COUNTY of FREDERICK
Department of Planning and Development
540/665-5651
FAX: 540/ 678-0682
January 13, 1997
Paul Negley
127 Mercedes Court
Winchester, Virginia 22602
RE: Negley Mini -Storage - Site Plan Approval
Site Plan #052-96
Dear Mr. Negley:
This letter is to inform you'that the Frederick County Planning Department administratively
approved site plan #052-96 on January 13, 1997. This site plan consists of: four self -storage
-buildings totaling 14,025 square -feet; 3 parking spaces with curb and gutter, one of the parking
spaces shall be a van accessible space with the necessary signage; and a 50-foot landscaped buffer"
along the southern property line. All driving surfaces around the storage buildings will be treated
with a minimum of a double prime -and -seal treatment. There is also a berm and a board -on -board
fence to be incorporated within the buffer area and along Mercedes Court. Plantings should be
installed in the buffer area and between the fence and Mercedes Court, as specified on the site plan.
Attached are two copies of the approved plan. This will enable you to provide your contractor with
an approved copy, and maintain a copy for your records. Please have the contractor contact this
office to schedule an on -site inspection once all improvements are complete.
Please contact me if I may answer any questions regarding this letter.
Sincerely,
Eric R. Lawrence
Planner II
Enclosure
cc: Charles W. Orndoff, Sr., Stonewall District Supervisor
John Lewis, Painter -Lewis, P.L.C.
Roy Jennings, Frederick County Real Estate
107 North Kent Street • Winchester, Virginia 22601-5000
COUNTY OF FREDERICK, VIRGI
DEPARTMENT OF INSPECTIONS
Caller f n()_ Time Called Date Called
Phone No.
•• I•� `� -
7-19 7-
Time Requested
1 '>O pit Date Requested 1
t
Received By
v�J
A
�r�/ `/r1 l i
Date of Inspection '�' 1 Z
PERMIT HOLDER NAME N 66,L ILI l rr err vC nu r�
RT. NO. 6 !- I Lot No. SEC. No. SUBDIVISION
STREET NAME
2G,1
DIRECTIONS f1lr nN"' ( R BUILDING NO. 4 72- ;-9-j
l�n r.� 0'i-T-b
1k) _� t-r„ ',
h >
PLUMBING NO.
1b ,+ "-C—
ELECTRICAL NO
DISTRICT
PERMIT FOR: �I�rJt I ��Ct-t�u� ��-jrci�ITI
Type of Inspection
Residential Commercial
Footers
Slab
Water
Sewer
Rough Plumbing
Groundworks
Other:
Setbacks: FR
(1D
MECHANICAL NO
SIGN NO
L
0
Draintile
Gas Fire -up
Final Electrical
Service
Framing
Final Mechanical
j
Rough Electric
Final
Site Plan
Rough Mechanical
Final Building
Fire Marshall
Gas Piping/Test
Final Plumbing
Special/Complaint
Time In: 1 ' O ''� Temperature `��1- Cut in No
Time Out: (- ,4 Weather
Results: Approved roc T 0-`1f C'_•u. Rejected
L (J �
Comments: orlP��Ti= T�trint �P �>TrZt() pn2r���iv fit,>r,ts�._� ('�12� 1��}C,
S l V "J � ��� r�fl t
Signature
Date `-� ! I Z'9 -�
2
W
4
5
SITE PLAN APPLICATION
Project Title: I "� �,A,(- 2tz��,;:97
Location of Property
(street address) L VACZZ
Property Owner:
Address:•����
vim-{ L ► 1v-1.43S��IiL � ✓�• ZZ Cam Z
Telephone:
t5
ApplicanUAgent
I? L�-v
Address
��Z SoOT" i3TZP• ��c S 1 S �3 ?mod
Telephone:
Z,—
Designer:
Address:
Telephone:
Contact:
6
• 'w
0
6. Is this an original or revised site plan?
7a. Total acreage of parcel to be developed:
7b. Total acreage of parcel:
8. Property Information:
a) Property Identification Number:
b) Current Zoning:
c) Present Use:
d) Proposed Use:
e) Adjoining Property Use(s)
f) Adjoining Property Identification Number(s)
g) Magisterial District(s)
Original
; ,l t9
Revised N
GI -:; �_, I�k� �i 5 z
� 1�l-�tc� �z�1�r �. , �r �►�-�', � Pit .;--
w�,-�at. �l3-4 41--(, 14_i,— kt -SLg,
w PTV
I have read the material included in this package and understand what is required by the
Frederick County Planning Department. I also understand that all required material will be
complete prior to the submission of my site plan.
Signature:
Date:
7
PAINTER-LEWIS, P.L.C.
CONSULTING ENGINEERS tel.: (540)662-5792
302 South Braddock Street, Suite 200 fax.: (540)662-5793
Winchester, VA 22601
2 JANUARY 1997
Mr. Eric Lawrence
Frederick County Department of Planning and Development
107 North Kent Street
Winchester. VA 22601
1Ze: NEGLEY MINI STORAGE SITE PLAN
Dear Eric:
Along with this letter you will find two copies of the site plan for the proposed mini storage
development on the property of Paul Negley on Welltown Pike. I am enclosing the comments
from the Fire Marshal, Engineering and Inspections. I have addressed your comments contained
in the letter dated December 3, 1996 as follows:
1. The setbacks have been added.
2. The exterior lighting will be building mounted only.
3. No outdoor storage areas are proposed for this project.
4. The trash receptacle exists in the northeast corner of the lot and is enclosed by a board
fence.
5. The parking stalls have been dimensioned.
6. One shade tree has been added to the plan.
7. The requirement for the landscape screen is 115.2 plants.
8. The board fence has been extended to the first entrance to the self storage units. Shade
trees have been added at 30' centers in front of the fence.
If you have any questions, please call me.
Sincerely;
J C. Lewis, P.E., C.L.A.
cc: P. Negley
file: 9610016
PAINTER-LEWIS, P.L C
•
COUNTY of FREDERICK
Department of Planning and Development
540i665-5651
FAX: 540/678-0682
December 3, 1996
John Lewis
Painter -Lewis, P.L.C.
302 South Braddock Street, Suite 200
Winchester, Virginia 22601
RE: Preliminary Site Plan Review -- Negley Mini -Storage
Site Plan #052-96
Dear John:
I have reviewed the above referenced site plan, submitted to my office November 18, 1996. The
following comments will need to be addressed in order for this office to proceed with the site plan
approval process. Please provide:
I ) Location and setbacks of all required setbacks and yard areas on the plan.
2) Location, height, and specifications of outdoor lighting fixtures.
3) Location and nature of outdoor storage areas.
4) Location of outdoor trash receptacles and dimension of structure required to enclose
receptacles. Is the receptacle already enclosed?
_5) Dimensions of all parking and loading spaces.
6) One shade tree to satisfy parking lot landscape requirements. The parking lot
interior landscaping requirement is 1 shade tree per 10 parking space. As with
parking space determination, fractions of' a tree should be increased to a whole
figure. Therefore, one shade tree is required.
7) Clarity on the number of trees required within the "B" category landscape screen.
My calculations indicate that 144 plantings are required over thjs 384.88' glhared"-»
property line. The plantings provided only total 116 trees.
Self-service storage facilities have additional performance standards that are outlined in Chapter
165, Section 44 of the Zoning Ordinance ( page 16566). I have enclosed a copy of these
performance standards. It is also Important to be aware that all amendment to the standards is
presently being considered by the County. I anticipate that the new standards will be adopted before
the end of the year. 'Hic existing standards will apply to this project, unless you Wish to implement
the proposed amendments. Please let me know which you chose to exercise.
107 North Kent Street • Winchester, Virginia 22601-5000
Negley Mini -Storage
Page 2
December 3, 1996
Existing self-service storage standards require a six -foot -high opaque wall or fence to totally
�, enclose the self -storage facility. The fence should be located no closer than 6 feet to a property line.
2andst aping is required within this six-foot border, between the fence and property line. The
existing requirement does not specify the type of paving to be used in and around the self -storage
buildings.
Proposed self-service storage standards will require that all parking areas, travel aisles, and
maneuvering areas be paved with asphalt or equivalent material. There is also a landscaping
requirement in leu of the fence requirement. The landscape requirement specifies that a double row
of evergreen trees be provided along the front setback, A single row of evergreen or deciduous trees
will be required in the side and rear setback areas.
Please revise your site plan to address these comments and the comments provided to you by the
required review agencies. Enclosed is a red -lined copy of the submitted site plan.
You will also need to provide this off ice with the completed approved comment sheets from the
following review agencies: Inspections Department, County Engineer, Pire Marshall, and this
department. Once all comments have been addressed, resubmit two copies of the plan to this office
for a final review. If the plan adequately addresses all comments, I will request five final copies and
recommend this plan for approval.
Please contact me with any questions,
Sincerely,
QE-ric.rence
Planner II
Enclosure
ERL/bah
•
•
Request For Site Plan Comments
Frederick County Engineering Department
Mail to: Hand deliver to:
Frederick County Engineering Dept. 107 N. Kent Street
Attn: Director of Engineering Fourth Floor
P.O. Box 601 Winchester, VA
Winchester, VA 22604 (540) 665-5643
(540) 665-5643
RECE1=_,
NOV d
FREDERICK CO-,
Please fill out the information as accurately as possible in order to assist the agency with their
review. Please attach two (2) copies of the site plan with this sheet.
Applicant's Name:-P--t t.AT,?12. - Ls , p• L- . �- -
Address: ST sUaT 2joU
ir•l l t.�C_t-�Br,Ti312 , fills, zZmy
Phone Number:
Name of development and/or description of the request:
Engineerin Department's Comments UTn, Revr'Bw o f
Ar
aDDBtz�-,VIC 14
Engineering Dept. use only
Date received
Incomplete
Date revic%ved
Signature and Date
Signature and Date (revise
Date revision received
Incomplete
Date revie\ued,�
Date approved f J qd
6
RECEIVED
NUN 1819�6
FREDERICK CO.�r
•
•
COUNTY OF FREDERICK, VIRGINIA
FIRE MARSHAL'S OFFICE
LAND DEVELOPMENT COMMENTS
Control No.1203960409 Date Received 111896
Applicant Painter -Lewis, P.L.C.
Address 302 S Braddock St.
Winchester, Virginia
22601
Date Reviewed 120396
Project NanieNegley Construction Phone No.540-722-9377
Type of ApplicationSite Plan Current Zoning
1st Due Fire Co. 13 1st Due Rescue Co. 13 Election District StonewalI
Tax I.D. No.
RECOMMENDATIONS
Automatic Sprinkler Systen'XX Residential Sprinkler System
Automatic Fire Alarm SystenKX Other
REQUIREMENTS
Emergency Vehicle Access
Adequate XX Inadequate Not Identified
Fire Lanes Required Yes XX No
CoIIIIIIenis
Roadway/Aisleway Widths Adequate XX Inadequate Not Identified
Special Hazards Noted Yes No XX
Comments
Hydrant Locations Adequate XX Inadequate Not Identified
Siamese Location Adequate Inadequate Not Identified XX
Additional Comments Attached? Yes No XX
Plan Approval Recommended? Yes XX No
Signatur e .�'�,2
Title����F�%�i��
•
Request For Site Plan Comments
Frederick County Inspections Department
Mail to:
Frederick County Inspections Dept.
Attn: Building Official
P.O. Box 601
Winchester, VA 22604
(540) 665-5650
Hand deliver to:
107 N. Kent Street
Fourth Floor
Winchester, VA
(540) 665-5650
Please fill out the information as accurately as possible in order to assist the agency with their
review. Please attach one (1) copy of the site plan with this sheet.
Applicant's Name:
Address:
Vet �ATtat,Z-
Z(10�
Phone Number: Z�116'" 62C Zl- C%t 2-
Name of development and/or descri tion of the request:
S
LDQ
Location of property: t-olATS o I , W TCXo �-t I k- (C2• Z 11tLa3S
Inspections Department's Comments:
Inspections Dept. use only
Date received _
Incomplete
Date reviewed _
Signature and Date
Signature and Date
conrnents on back of form
Date revision received
Inc iplete
to revi
Date approved
RECEIVED
a
FREDERICK CO.
IT
•
•
Building shall comply with the Virginia Uniform Statewide Building Code and section 311
Use Group S (Storage) of the BOCA National Building Code / 1993. Other Codes that apply
are title 24 Code of Federal Regulation, Part 36 Nondiscrimination on the Basis of
Desability by Public Accommodations and in Commercial Facilities. ADA parking and
building access appears to be in compliance.
ti • t�CFY
SELF-SERVICE STORAGE FACILITY AMENDMENTS
165-82. District use regulations.
D) M1, Light Industrial District.
Allowed Uses ii
Self-service storage facilities ----
16544. Self-service storage facilities.
Where allowed, self-service storage facilities shall meet the following requirements:
A) Self-service storage facility operations shall be permitted as a primary or accessory use in
all zoning districts in which they are permitted.
B) All parking areas, travel aisles, and maneuvering areas associated with the self-service
storage facility operations shall be paved with asphalt, concrete, or similar material to
provide a durable hard surface.
C) Buildings are permitted that provide interior and exterior accessible units. Individual units
within the self-service storage building shall not exceed one -thousand (1000) square feet in
area.
D) Minimum building spacing shall be thirty (30) feet apart. Loading areas shall be delineated
to ensure that adequate travel aisles are maintained between buildings.
E) Recreational vehicles and boats shall be permitted to be stored within completely enclosed
areas of the self-service storage facility provided that the storage area is separate from the
parking areas and travel aisles, and is depicted on the approved site development plan.
Areas utilized for this purpose shall be exempt from the surface requirements specified
under section 165-44(B).
F) Self-service storage facilities shall meet the following landscaping or screening
requirements:
1 ) Facilities located in the B-2, Business General District shall be completely screened
around the perimeter of the property by a double row of evergreen trees that are
staggered and planted a maximum of eight (8) feet off center, and are a minimum cif
six (6) feet in height when planted.
•
F) Self-service storage facilities shall meet the following landscaping or screening requirements
(continued):
(2) Facilities located in the B-3, Industrial Transition District, or the M-1, Light
Industrial District, shall be required to landscape the yard area within the front yard
setback to provide for a double row of evergreen trees that are staggered and planted
a maximum of eight (8) feet off center. The side and rear yards shall be planted with
a single row of evergreen or deciduous trees that are planted a nlaxinnun of forty
(40) feet off center. All trees shall be a minimum of six (6) feet in height at the time
of planting.
(3) Facilities located on parcels that are within a master planned industrial park or office
park shall be required to landscape the perimeter of the facility with a single row of
evergreen or deciduous trees that are planted a maximum of forty (40) feet off
center. All trees shall be a minimum of six (6) feet ill height at the time of planting.
(4) The required planting of all trees described under subsection F shall occur in an area
that is between the adjoining property boundary line and the placement of security
fencing. The installation of an opaque wall or fence that is a nlininlunl of six feet
in height may substitute for required landscaped areas in all zoning districts.
G) Self-service storage facility operations shall be designed to accommodate the storage of
residential, commercial, and Industrial items, excluding hazardous, toxic, and explosive
materials. No use, sale, repair, or activity other than storage shall be permitted to occur ill
self-service storage facility operations. A copy of the lease agreement which describes the
requirements of this subsection shall be approved in conjunction with the site development
plan for the self-service storage facility operation.
•
§ 165-41 FREDERICK COUNTY CODE § 165-44
A. All dogs shall be confined to secure pens or structures.
B. Where kennels are allowed, zoning district separation buffers and
screens, Category C as described by this chapter, shall be provided in
relation to surrounding properties containing residential uses.
§ 165-42. Operation of slaughterhouses and rendering plants.10
A. It shall be unlawful to operate any slaughterhouse, abattoir, rendering
plant or establishment where animals or fowl, dead or alive, are
processed or where food or feed is manufactured or processed, unless
such place or establishment is maintained and operated in a clean and
sanitary manner at all times.
B. Such establishments shall be so constructed and maintained as to
effectively control the entrance of insects and rodents. The doors,
windows and other openings thereof shall be fitted with screen doors
and wire window screens of not coarser than 14-gauge mesh.
C. The word "slaughterhouse," as used in this section, shall not be
construed to prohibit persons who are actually farmers from killing
their own cattle, sheep, swine, goats and fowl for their own family. use. ^`
§ 165-43. Motor vehicle service uses and public garages.
All motor vehicle service uses and public garages shall meet the following
requirements:
A. All repair shall take place entirely within an enclosed structure.
B. All exterior storage of parts and equipment shall be screened from view
of surrounding properties by an opaque fence or screen at least five (5)
feet in height. This fence or screen shall be adequately maintained.
§ 165-44. Seff-service storage facilities.
Where allowed, self-service storage facilities shall meet the following
requirements.
10Editor's We: Added at time of adoption of Code; see Ch. 1, General Provisions, Art. II.
16566 l
J
,Y •
•
§ 165-44 ZONING § 1.65-45
A. Only personal property associated with household use shall be stored
in self-service storage facilities.
B. Materials stored shall not be used or sold within the self-service storage
facility. No commercial activities of any kind shall occur within the
facility. No repair of vehicles, furniture or other materials or equipment
shall occur within the facility. Signs shall be posted within the facility
describing such limitations.
C. No storage of hazardous, toxic or explosive materials shall occur in the
self-service storage facility. Signs shall be posted within the facility
describing such limitations.
D. The maximum size of any individual storage space or unit in a self-
service storage facility shall be five hundred (500) square feet.
E. The self-service storage facility, including loading areas and all storage
areas, shall be totally enclosed by structures or by a six -foot -high
opaque wall or fence. Such fences shall be set back at least six (6) feet
from property boundaries. Landscaping shall be provided in such
setback areas, including trees and shrubs.
F. All storage shall be within an enclosed structure. The Zoning
Administrator may allow the storage of personal vehicles associated
with household use within areas enclosed by the fence or wall.
G. For storage units that open to the outdoors, a twenty -foot -deep loading
aisle or space shall be provided adjacent to each unit. Such loading
aisles shall be separate from driveways used for internal circulation.
H. Before a site plan is approved for a self-service storage facility, a copy
of the lease agreement shall be submitted to the Zoning Administrator
for review and approval to ensure that the limitations described in this
section have been included in the lease agreement.
§ 165-45. Temporary trailers.
A. Temporary trailers shall be allowed as a part of construction projects.
However, they shall not be used for residential purposes. In addition,
temporary trailers shall be removed before a final certificate of
occupancy is issued for the use under construction. All such trailers
shall meet applicable requirements of the Frederick County Code. In
16567
N&�cEy AW,-s104q-C—
SITE PLAN CHECKLIST
The checklist below indicates all the information that needs to be submitted as part of the site plan
application. All required information must be submitted prior to the final approval of any site plan.
The Department of Planning and Development will review the application to ensure that it is complete.
If any portion is not included or complete, the site plan application will not be accepted and returned
to the applicant(s).
Site Plan Package
1. One set of approved comment sheets are required from the following review
agencies prior to final site plan approval. It is recommended that applicants contact
the Department of Planning and Development to determine which review agencies
are relevant to their site plan application.
Virginia Department of Transportation (VDOT)
Fredenck County Sanitation Authonty
1**" Department of Planning and Development
-� Inspections Department
✓Fredenck County Engineer (Puolic Works)
-,/Fredenck County Fire Marshal
Departrnent of Parks and Recreation
2. One copy of the Site Plan application
3. Five Copies of the Final Site Plan for approval
4. One reproducible copy of the Site Plan (if required)
5. A 35mm slide of the Site Plan (if required)
8
County Health Cepartment
City of Wincnester
Town of Stephens City
Town of Middletown
Airport Authority
Soil & Water Conservation District
•
•
Site Plan Information Checklist
The following information must be inciuded an your site plan. If your site plan is incomplete or
is missing information, it will not be reviewed and returned to you for revisions.
Administrative Information
Y N
1. Name of proposed development.
2.
Name, address, and phone number of owner.
3.
Name, address, and phone number of developer.
4.
Name, address, and phone number of designer.
5.
Certificate of surveyor, engineer, or architect.
r
6.
Date plan prepared and date of revisions.
7.
A listing of all conditions placed on the site as a result of a
conditional use permit or conditional zoning approval.
8.
A space labeled Approved by the Zoning Administrator" for
the approval signature and date of approval.
9.
A description of setbacks or conditions placed on the site as a
result of a variance approval. (Reference the variance
application number.)
General Site Information
Y N
10.
Location map (scale 1:2000)
_.
11.
Magistenal District
12.
Scale of site plan (not to exceed 1:50)
13.
North Arrow
Zoning of site .1
Use, zoning, and Property Identification Number (PIN#) of all
adjoining properties. This includes properties located across
rignt-of-ways, streams, and railroad tracks.
16.
Surveyed boundaries for all lots and parcels.
I
9
General Site fcon't
Y N
J17.
Acreage of all lots included in the plan.
18.
The location and dimensions of all required setbacks and yard
areas.
19.
The location and type of all dwelling units.
20.
Location and description of all recreation facilities.
21.
Location of sidewalks and pedestrian ways.
22.
Location and area of common open space.
/
23.
The location, height, and dimensions of all signs.
/
24.
Location, height, and specifications of outdoor lighting fixtures.
25.
Location and nature of outdoor storage areas.
. ,
26.
Location of outdoor trash receptacles and dimensions of
structure (fencing, etc.) required to enclose receptacles.
ALE AT>I >JtL.iED .
Buildina Information
Y N
27. The height of all buildings and structures.
28. Location of all buildings, structures and uses.
29. The proposed use of each building, structure and area.
✓ 30. Ground floor area and total floor area of all buildings with PAR
calculations for commercial and industrial zoning districts.
Roads
Y N
31. Name and number of existing and planned streets on and
adjoining the site.
32. Location of existing and planned streets on and adjoining the
site.
33. Posted speed limit of existing adjacent roads.
34. Location and dimensions of all proposed entrances from public
right-of-ways.
0
Utilities
Y N
Parking
Y N
Natural Features
Y N
35. Location of all entrances on adjoining roads within 200 feet of the
proposed or existing entrance.
36. Dimensions, boundaries, width, pavement, and construction of
planned roads.
37. Location of all utilities, inducting sewer and water fines with the
size of lines, mains, and laterals.
38. Location and width of all easements, including access, utility,
and drainage easements.
Location and nature of fire lanes, fire hydrants, and all other
facilities necessary to meet Fire Code requirements.
40. Calculations describing the required number of parking and
loading spaces. F P'l S ° o L °°"
41. Location and dimensions of all parking and loading spaces,
driveways, parking aisles, curbing and other features to be used.
42. Location and dimension of all disabled parking spaces and
ramps.
43. Existing and finished contour lines.
44. Location of steep slopes, woodlands, flccdplains, wetlands,
sinkholes, and other environmental features.
45. Location of streams and drainage ways.
t
11
•
Landscaping
Y N
46. Landscaping plan describing location and types of plants to be
used.
47. Location of required buffers and screening with cross sections or
profiles.
Erosion and Sediment Control
Y . N
48. A stormwater management plan with run off calculations and
location and description of facilities to be used.
49. Soil erosion and sedimentation control plan describing the
location and methods to be used to minimize erosion and
sedimentation during development
12
•
Request For Site Plan Comments
Department of Planning and Development
Mail to: Hand deliver to:
Department of Planning and Development 107 N. Kent Stre(
Attn: County Planner Fourth Floor
P.O. Box 601 Winchester, VA
Winchester, VA 22604 (540) 665-5651
(540) 665-5651
Please fill out the information as accurately as possible in order to assist the agency with their
review. Please attach two (2) copies of the site plan with this sheet.
Applicant's Name: _-VES.A (Z- - LyOwUS r � I L , G
Address:
G
Phone Number: 90- ��(�7�-�'��( Z
Name of development and/or description of the request:
Location of property: G, ( Wel_.� T c� �-1 -P� k-� , cam, 2 ft� S
11� lr L 01 T:�� 11
Planning and Development's Comments:
0
F-1
\J
PAINTER-LEWIS, P.L.C.
CONSULTING ENGINEERS tel.:
302 South Braddock Street, Suite 200 fax.:
Winchester, VA 22601
18 NOVEMBER 1996
Mr. Evan Wyatt
Frederick County Department of Planning and Development
107 North Kent Street
Winchester, VA 22601
Re: NEGLEY MINI STORAGE SITE PLAN
Dear Evan:
(540)662-5792
(540)662-5793
Along with this letter you will find a site plan for a mini storage development on the property of
Paul Neglcy on Welltown Pike. I have requested site plan comments from the Dire Marshal,
Engineering and Inspections. If there are other agencies which must review these plans. please let
me know.
Included herein arc the following items:
• 2 copies of the plans
Site Plan application
• fee check in the amount of $1,150.00
Site Plan comment sheet
If you have any questions, please call me.
.19fin C. Lewis, P.E., C.L.A.
cc: P. Negley
file: 9610016
PAINTER-LEMS, P.L.C.