Loading...
HomeMy WebLinkAbout20-02 Eastern Supply (storage bldg.) - Stonewall - Backfile0 co 0 g d v N of 0 N O 0 0 W U ti m a� Z W w F_ W w m 0 n� M 0 GENERAL NOTES VD0T GENERAL NOTES LEGEND VICINITY MAP C'3 1. Methods and materials used in the construction of the improvements herein shall conform to the current Vl. All work on this project shall conform to the latest editions of the Virginia Department ofTransportation (VDOT) Road and Bridge Specifications and Standards, the Virginia Erosion and EXISTING INTERMEDIATE CONTOUR -� _ -- �- b �- -W "`M -. SCALE: 1" = 1200' County construction standards and specifications and/or current VDOT standards and specifications. Sediment Control Regulations and any other state, federal or local regulations applicable. In the 8 `�"' W event of conflict between any of these standards, specifications or plans, the most stringent shall be EXISTING INDEX CONTOUR -� -- 330 `' 2. Measures to control erosion and siltation, including detention ponds serving as silt basins during construction, govern. C,y W must be provided prior to issuance of the site development permit. The approval of these plans in no way PROPOSED CONTOUR 40 relieves the developer or his agent of the responsibilities contained in the Virginia Erosion and Sediment V2, All construction shall comply with the latest U.S. Department of Labor, Occupational Safety and EXISTING EDGE OF PAVEMENT - - -- -- E`P.__ _�. ��0� Z Control Handbook. Health Administration and VOSH Rules and Regulations. PROPOSED EDGE OF PAVEMENT PROP E/P .,ry2 ♦ R 3. A permit must be obtained from the Office of the Resident Engineer, Virginia Department of Transportation V3. When working on VDOT right-of-way, all traffic control, whether permanent or temporary, shall EX C-4 15 _- Z (VDOT) and Frederick County prior to construction in existing State right-of-way• be in accordance with the current edition of VDOT's work area protection manual. Furthermore, all EXISTING CURB AND GUTTER --_=- ---_= _----_ ---- -_--- -----= J� 4. Approval of this plan does not guarantee issuance of an entrance permit by VDOT when such permit is traffic control flaggers must be certified in accordance with the latest edition of the VDOT Road and PROP C&G ��, tb W N CD required under State law. Specifications, Section 104.04-C. PROPOSED CURB AND GUTTER ' �; CD 5. The exact location of all guard rails will be determined by VDOT personnel. "A joint inspection will be held V4. The developer shall be responsible for relocating, at his expense, any and all utilities, including traffic signal poles, junction boxes, controllers, etc. owned by VDOT or private utility company. It is ��--� -- -'�- �-- �-" -"-� `�� �-�� TRANSITION FROM CG-6 TO CG-6R --____ - J tir \v P'r N ono 'IT d i with the Developer, County Representatives, and Representatives of the Virginia Department of Transportation the developer EXISTING TELEPHONE LINE _ __�.___ - ._ _�._ __�___ .__ C� Q �, N (VDOT) to determine if and where guard rail and/of paved ditches will be needed. The developer will be sole responsibility of the to locate and identify utility facilities or items, which may be in conflict with the proposed construction activity. VDOT approval of these plans does not PROPOSED TELEPHONE LINE T (� '- __ � a \D N L GN responsible for providing guardrail and paved ditches as determined b this joint inspection." Refer to P P g g P Y j P relieve the developer of this responsibility. 11 U,y J i m Virginia Department of Transportation (VDOT) Guard Rail and Paved Ditch Specifications. EX, 15" R,6P EXISTING STORM SEWER ,,__-�-= ; ��.---- _-�._--�--- W _li-'TE- � � 't i Z cu V5. Design features relating to field construction, regulations, and control or safety of traffic may 6. An approved set of plans and all applicable permits must be available at the construction site. Also, a be subject to change as deemed necessary by VDOT. Any additional expense incurred as a result of PROP. 15" RGP -� _W ni, representative of the developer must be available at all times, any field revision will be the responsibility of the developer. PROPOSED STORM SEWER W Ln o 0 N -C 7. Warning signs, markers, barricades or flagmen should be in accordance with the Manual on Uniform Traffic V6. Prior to initiation of work, the contractor shall be responsible for acquiring all necessary VDOT EXISTING SANITARY SEWER 3 v Control Devices (MUTCD). land use permits for any work on VDOT right-of-way. PROPOSED SANITARY SEWER PROJECT INFORMATION 9 x Ln 3 8. All unsuitable material shall be removed from the construction limits of the roadway before placing V7. If required by the local VDOT Residency Office, a pre -construction conference must be arranged EXISTING ELECTRIC SERVICE embankment. and held by the engineer and/or developer with the attendance of the contractor, various County Ln 9. All pavement sections on the approved plans are minimum sections to be utilized when the actual California agencies, utility companies and VDOT prior to initiation of work. PROPOSED ELECTRIC SERVICE EX STREET ADDRESS 240 McGHEE ROAD ^� Ln L o rl- Bearing Ratio (CBR) of the pavement subgrade is 6 or more. Soils tests of the subgrade shall be performed V8. The contractor shall notify the local VDOT Residency Office when work is to begin or cease for EXISTING GAS LINE ---------------------- WINCHESTER, VA 22601 hN GJ >, n, for actual determination of required pavement thickness prior to placement. All final pavement and base q P P P P an undetermined length of time. VDOT will also require 48 hours notice for an inspection. Y g q Y P PARCEL IDENTIFICATION NO, 43-((19))-39 t" > course thicknesses shall be designed in accordance with VDOT's Pavement Design Guide for Subdivision and V9. The will be for to the PROPOSED GAS LINE G G LOT AREA 5.3185 AC. �, 3 Secondary Roads in Virginia", and shall be based on a sufficient number of CBR tests to determine the true contractor responsible maintaining adequate access project from the DISTURBED AREA 7,200 S.F. support values of the soils in the subgrade. Final pavement design shall be submitted during construction adjacent public roadway through construction and maintenance of a construction entrance in PROPERTY LINE accordance with the Virginia Erosion and Sediment Control Handbook, Section 3.02. Furthermore, CURRENT ZONING M 1 and prior to placement. access to other properties affected by this project shall be maintained through construction. The FLOW LINE ....... CURRENT USE MANUFACTURING / WAREHOUSE 10. All roadside ditches at grades of more than 5% shall be paved with cement concrete to the limits indicated g P Developer shall have, within the limits of the project, an employee certified by the Department of Conservation and Recreation in Erosion and Sediment Control who shall inspect erosion and siltation FENCELINE _._.____ PROPOSED USE MANUFACTURING /WAREHOUSE on the plans and as required at the field inspection. control devices and measures for proper installation and deficiencies immediately after each rainfall, EXISTING POWER POLE BUILDING HEIGHT• MAXIMUM ALLOWED = 60' PROPOSED = 16' il. All springs shall be capped and piped to the nearest storm sewer manholes or curb inlet. The pipe shall at lest daily during ed rainfall,when no rainfall event occurs and weekly , y . SIGNS: ALL SIGNAGE MUST CONFORM WITH THE be minimum 6" diameter and conform to VDOT standard SB-1. V10. Contractor shall ensure adequate drainage is achieved and maintained on the site during and EXISTING TELEPHONE POLE �� STANDARDS OF SECTION 165-30 OF 12. Construction debris shall be containerized in accordance with the Virginia Litter Control Act; no less than at the end of construction. EXISTING WATERLINE W/ TEE THE FREDERICK COUNTY ZONING ORDINANCE. one litter receptacle shall be provided at the construction site. Vll. All water and sewer lines within existing or proposed VDOT right-of-way are to have minimum PROPOSED WATERLINE W/ TEE OUTDOOR LIGHTING: EX. OUTDOOR LIGHTING FIXTURES 13. The contractor shall provide adequate means of cleaning mud from trucks and/or other equipment prior to 36" cover and, when possible, to be installed under roadway drainage facilities. BUILDING SETBACKS: REQUIRED: FRONT: 75' PROPOSED: FRONT: 111.1' entering public streets, and it is the contractors responsibility to clean streets, allay dust, and to take EXISTING FIRE HYDRANT SIDE: 25' SIDE: 26', 259.8' 25' 418.4 whatever measures are necessary to insure that the streets are maintained in a clean, mud and dust free V12. Any unusual subsurface conditions encountered during the course of construction shall be REAR. REAR: condition at all times. immediately brought to the attention of the engineer and VDOT. Work shall cease in that vicinity EXISTING WATER VALVE until an adequate design can be determined by the engineer and approved by VDOT. 14. * Notification shall be given to the appropriate utility company prior to construction of water and/or sanitary V13. All fill areas, borrow material and undercut areas shall be inspected and approved by a VDOT PROPOSED WATER METER ® PARKING CALCULATIONS LANDSCAPED AREA REQUIRED sewer lines. Information should also be obtained from the appropriate authorit concerning permits, cut Y g P representative prior to placement and fill. Where CBR testing is required, a VDOT representative P P P g q P EXISTING REDUCER REQUIRED 25% = 57,918 S.F. sheets, and connections to existinglines. shall be present to insure the sample obtained is representative of the location. When soil samples PROPOSED REDUCER (NO LANDSCAPED AREA LOST DUE TO PROP. BLDG.) 15. All sanitary sewers and water mains and appurtenances shall be constructed in accordance with the current are submitted to private laboratories for testing, the samples shall be clearly identified and labeled -�- OFFICE = 1 SPACE PER 250 S.F. EX. BUILDINGS = 13,200 S.F. standards and specifications of Frederick County and/or the Frederick County Sanitation Authority. as belonging to a project which will be accepted by VDOT and that testing shall be conducted STOP SIGN WAREHOUSE = 1 SPACE PER EMPLOYEE EX. PAVED & GRAVEL AREA = 147,900 S.F. according to all applicable VDOT standards. HANDICAP RAMP (CG-12) f'� --`"� `�'-� FABRICATION = 3 SPACES PER EMPLOYEE TOTAL = 161 100 S.F. 16. The location of existing utilities shown in these lens are taken from existing records. It shall be the g P g contractors responsibility to verify the exact horizontal and vertical location of all existing utilities as needed V14. All roadway fill, base, subsurface material and backfill of utility/storm sewer trenches shall be DENOTES LOCATION OF STD VDOT CG-12 jn- OR JUR�SD� IONA 0 � (� �" U compacted in 6' lifts to 95% of theoretical maximum density as determined by AASHTO T-99 Method STAND,D CO CTIO EX. OFFICE = 1,000 S.F. = 4 SPACES 231,674 S.F. - 161,100 S.F. = 70,574 S.F. prior to construction. The contractor shall inform the engineer of any conflicts arising from his existing the within plus or minus 2% of optimum moisture for the full width of any dedicated street PARKING INDICATOR 574 S.F. 70,.A, EX. WAREHOUSE = 0 EMPLOYEES / 231674 S.F. = 31 % utility verification and proposed construction. right-of-way. At the direction of VDOT Inspector, density tests performed by a qualified INDICATES THE NUMBER OF TYPICAL PARKING SPACES 12 EX. FABRICATION = 8 EMPLOYEES = 6 SPACES Z E -+ Z 17. The developer will be responsible for any damage to the existing streets and utilities which occurs as a independent agency shall be conducted as required in the VDOT Road and Bridge Specifications. A Q am result of his construction project within or contiguous to the existing right-of-way. copy of all tests shall be submitted to VDOT prior to final VDOT approval. TEST PIT LOCATION (D Q �)4 Z'-' a 18. When grading is proposed within easements of utilities, letters of permission from all involved companies V15. VDOT Standard CD and UD under -drains shall be installed where indicated on these lens and P further where determined necessary by VDOT Inspector. TOTAL SPACES REQUIRED = 10 F.A.R. P-, � �D � must be provided to Frederick County Sanitation Authority prior to issuance of grading and/or site HANDICAP PARKING TOTAL EXISTING SPACES == 24 EX. BUILDINGS = 13,200 S.F. development permits. V16. The installation of any entrances and mailboxes within any dedicated street right-of-way shall � EX. SPACES LOST DUE TO PROP. BUILDING = 7,200 S.F. ,_., W co 0., >'' The developer will be responsible for the relocation of any utilities which is required as a res?a.lt of his meet VDOT minimum design standards and is the responsibility of the developer. VEHICLES PER DAY COUNT 100 PROPOSED BUILDING _ 4 TOTAL = 20,400 S.F. W F'' 20,400 S.F.19. / 231 ,674 S.F. = 0.088 � project. The relocation should be done prior to construction. V17. Prior to acceptance by VDOT of any streets, any required street signage and/or pavement PROPOSED BUILDING ENTRANCE TOTAL REMAINING SPACES . = 20 i Z O 20. These plans identify the location of all known gravesites. Gravesites shown on this plan will be protected markings must be installed by the developer or at VDOT's discretion, by VDOT on an account NO ADDITIONAL EMPLOYEES ARE PROPOSED 0 O � ;� U in accordance with state law. In the event gravesites are discovered during construction, the owner and t thi shall b h i St i b a.ss. op signs sae thirty () inches tall with high intensity sheeting. The receivable.-, ENVIRONMENTAL FEATURES �30 W a'' engineer must be notified immediately. bottom of the sign shall be six (6) feet above the edge of pavement and the post shall be installed EXISTING STREET LIGHT -` � Q-,' � x a minimum of four (4) feet from the edge of pavement. Sign posts shall be of a type found on HANDICAP PARKING FEATURE EX. ACREAGE C-) 21. The contractor is to verify field conditions prior to and during construction and notify Greenway Engineering VDOT's approved list. A copy of this list may be obtained from the District Material Section. Contact the local VDOT Residency Office with an regarding sin material and PROPOSED STREET NAME SIGN FLOODPLAINS 0 1 -25 = 1 SPACE REQUIRED LAKES & PONDS 0 ,'s a � at (540) 662-4185 immediately of any discrepancies between actual field conditions and the approved plan. questions placement. Y Y q g g g P EX. HANDICAP SPACES = 1 "A" V18. The developer must provide to the local VDOT office a list of all material sources to PROPOSED SANITARY LATERAL CLEANOUT WETLANDS PL 1 AC. 0 �1 Q W 22. Controlled fills shall be compacted to 95% of maximum density as determined by method per standard prior SINKHOLES 0 W W proctor AASHTO-T99, ASTM-D698, or VTM-1 as applicable. Density shall be certified by a registered construction. Copies of all invoices for materials within any dedicated street right-of-way must be provided to the local VDOT Residency Office prior to acceptance of the work. Unit and total prices SANITARY MANHOLE IDENTIFIER 12 LOADING SPACES NATURAL STORM WATER U1 Q Z � professional engineer and results submitted to Frederick County prior to pavement construction. If a be REQUIRED: 1 PER 40,000 S.F. OF FLOOR AREA DETENTION AREAS 0 W geotechnical report has been prepared, it should supersede the requirements in this note. may obscured. STORM DRAIN STRUCTURE IDENTIFIER 6 TOTAL FLOOR AREA = 20,400 S.F. STEEP SLOPES PL 15% 0 a O E- V19. Aggregate bases and sub -bases shall be placed on the sub -grade by means of a mechanical SPACES REQUIRED = 1 WOODLANDS 0 X U1 23. Contractors shall notify operators who maintain underground utility lines in the area of proposed excavating spreader. Density will be determined using the density control strip as specified in VDOT's Road and SPACES PROVIDED = 2 a.,, or blasting at least two (2) working days, but not more than ten (10) working days, prior to commencement Bridge Specifications -Section 304 and VTM-10. A certified compaction technician shall perform these EASEMENT LINEof excavation or demolition. Names and telephone numbers of the and operators underground utility lines tests. A certified copy of the test results shall be provided to the Residency Office. In additions to PREVIOUS APPROVED PLAN #66-99 in Frederick County appear below. These numbers shall also be used to serve in an emergency condition. checking stone depths, a VDOT representative shall be notified and given the opportunity to be CENTERLINE present during the construction and testing of the density control strip. EXISTING SPOT ELEVATION I � ���' TRIP GENERATION DATA UTILITY CONTACTS V20. Asphalt concrete pavement shall be placed in accordance with the latest edition of VDOT's Road + and Bridge Specifications -Section 315. Density will be determined using the density control strip as specified in Section 315 and VTM-76. A certified compaction technician shall perform these tests. PROPOSED SPOT ELEVATION 115.1 CLASS USE S.F. EMPLOYEES TRIP RATE USE VPD Water/Sewer: Frederick County Sanitation Authority Gas: Shenandoah Gas Co. A certified copy of the test results shall be provided to the Residency Office. A VDOT representative EXISTING TREE LINE P.O. Box 1877 P.O. Box 2400 Winchester, VA. 22604 Winchester, VA 22604 shall be notified and given the opportunity to be present during the construction and testing of the control strip. EXISTING TREE c `-'� 15" OAK I FINE 140 MANUFACTURING 6000 5 2.0 / EMPLOYEE 3.8 / 1000 S.F. 10 23 (540) 868-1061 (540) 869-1111 �" V21. Approval of these plans shall expire three (3) years from the date of the approval letter. Power: Allegheny Power Phone: Verizon P.O. Box 1458 P.O. Box 17398 V22. Final location of CG-12 Curb Ramps shall be determined by VDOT inspector. PROPOSED TREE crrj IT OAK 15, PINE TOTAL 33 Hagerstown, MD 21741 Baltimore, MD 21297 1-800-654-3317 (301) 954-6282 FCSA CONSTRUCTION NOTES MISS UTILITY 1-800-257-7777 1. WATER AND LINES ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THESE SHALL ADDIT ONALLYRMEET ALL REQUIREMENTS OF THE FREDERICK COUNTY SANITATIONAUTHORITY.PLANS. BATE REVISION SEAL CO VER SHEET FIRE MARSHALL'S NOTE 2. THE CONTRACTOR SHALL COORDINATE WITH, AND ARRANGE FOR INSPECTION BY THE AUTHORITY. 3. EXACT LOCATIONS OF WATER AND SEWER SERVICES ARE TO BE COORDINATED WITH THE AUTHORITY'S INSPECTOR. 5/2q/02 PER V.D.O.T. COMMENTS Project Name: j EASTERN SUPPLY 8/1/02 FRED. CO. PLANNIN G COMMENTS FIRE LANE MARKINGS AND SIGNAGE Any "No Parking" signs and yellow painted curb 4. THE SANITATION AUTHORITY'S MAINTENANCE DEPARTMENT IS RESPONSIBLE FOR THE INSTALLATION OF Owner: Address, Including Zip Code &Telephone No. locations will be installed by field inspection at WATER METERS THROUGH 2" IN SIZE. BEFORE A PERMANENT METER IS SET, THEY REQUIRE: 1) THE FRAME the direction of the Fire Marshall's office. AND COVER TO BE PROPERLY ALIGNED WITH ITS METER BOX AND YOKE BAR; 2) THE FRAME AND COVER TO BE SET TO THE FINAL GRADE OF THE LOT; 3) THE DISTANCE BETWEEN THE TOP OF THE COVER AND YOKE 195 EBERT ROAD (P.O. BOX 1445) BAR BE BETWEEN 18 AND 21 INCHES; AND 4) ALL COMPONENTS OF THE METER BOX ASSEMBLY TO BE IN MAR D, $ H 9 T.S.M., INC. WINCHESTER, VA 22604 PROPER WORKING ORDER. IT IS THE DEVELOPER'S/CONTRACTOR'S RESPONSIBILITY TO HAVE THE METER BOX wO N0.022837 (540) 722-3292 ASSEMBLY INSTALLED CORRECTLY. � Z Developer: Address, Including Zip Code &Telephone No. E &S NARRA TI VE 5. FOR WATER AND SEWER SERVICES THAT CONNECT TO EXISTING LINES: 195 EBERT ROAD (P.O. BOX 1445) A. THE LOCATION OF THE SERVICE LATERAL IS TO BE COORDINATED WITH THE AUTHORITY'S ENGINEERING ASSISTANT. AN APPLICATION FOR SERVICE MUST BE MADE AND FEES PAID BEFORE WORK WILL BEGIN. `SIO MAh _ EASTERN SUPPLY i- -., ICU" CI^\� `_ WINCHESTER, VA 22604 (540) 722-3292 SHEET INDEX Project Description B. THE AUTHORITY SHALL FURNISH AND INSTALL ALL 5/8", 3/4" AND 1" WATER SERVICES. Engineer Certifying Plan: 2 M 4 Address, Includin Zip Code & Telephone No. g P P The purpose of this project is for the construction of a 7,200 S. F. storage building. C. FOR ALL 1 1/2" AND 2" WATER SERVICES, THE AUTHORITY SHALL MAKE THE TAP AND BRING THE PIPING TO THE PROPERTY LINE. THE CONTRACTOR IS TO FURNISH & INSTALL THE METER VAULT ASSEMBLY. 151 WINDY HILL LANE Adjacent Properties THE AUTHORITY WILL INSTALL THE METER. D. THE AUTHORITY WILL INSTALL ALL SEWER LATERALS. GREENWAY ENGINEERING "CFT, CF P��,''� e --EVELOPMEN'T WINCHESTER, VA 22602 The adjacent properties are owned by James and Jessie Wilson, Lenoir City Co., and Rite Aid of Virginia, Inc. (540) 662-4185 PROFESSIONAL SEAL &SIGNATURE 6. WHEN AN EXISTING WATER MAIN IS TAPPED FOR THE INSTALLATION OF A NEW LINE: COVER SHEET SHEET 1 " q ` `- Erosion Control Program Install silt fence A. THE AUTHORITY SHALL FURNISH ALL LABOR AND MATERIALS TO MAKE THE TAP. B. THE DEVELOPER/CONTRACTOR MUST: 1) MAKE APPLICATION FOR THE TAP, 2) PAY DEPOSIT (BEFORE SITE PLAN SHEET 2 APPROVAL DATE; 04/24/02 THESE PLANS ARE IN CONFORMANCE WITH WORK BEGINS); 3) MARK THE LOCATION OF THE TAP; AND 4) MAKE FINAL PAYMENT WHEN THE WORK IS SCALE, N/A Maintenance Program COMPLETED. COUNTY OF FREDERICK STANDARDS AND ORDINANCES. ANY DEVIATION OR CHANGE DESIGNED BY: 1. The contractor will inspect all erosion and sediment control measures after each rainfall and at least daily during rainfall. Damaged and/or deficient areas will be repaired or improved immediately 7. THE CONTRACTOR SHALL TIE-IN A NEW LINE TO AN EXISTING MANHOLE BY CORE DRILLING THE MANHOLE. IN THESE PLANS SHALL BE APPROVED BY � a���f`C %6 C.7�',�-� GWY prolonged 2. Furthermore, the contractor will make a daily review of areas of construction activity to insure erosion 8. ANY WATER SERVICE LINE MUST HAVE A DOUBLE CHECK VALVE OR RPZ BACKFLOW PREVENTION THE ZONING ADMINISTRATOR PRIOR TO AS control effectiveness. Additional measures will be installed immediately where deficiencies are found. ASSEMBLY, AS REQUIRED, INSTALLED. THE ASSEMBLY SHALL MEET ASSE STANDARD No. 1015 OR 1013. A CONSTRUCTION. FREDERICK COUNTY ZONING ADMINISTRATOR DATE REMOTE READOUT IS REQUIRED. 3. Permanent erosion control measures include the establishment of grass on exposed surfaces disturbed 9. ALL FIRE LINES SHALL HAVE A DETECTOR DOUBLE CHECK VALVE BACKFLOW PREVENTION ASSEMBLY OR A JOB N0. 0617 in the construction process, excluding the road surface. RPZ BACKFLOW ASSEMBLY AS REQUIRED. THE ASSEMBLY SHALL MEET ASSE STANDARD No. 1048 OR 1047. * SITE PLAN VALID FOR (5) FIVE YEARS FROM DATE OF PLANNING DEPT APPROVAL A REMOTE READOUT IS REQUIRED. * SITE PLAN VALID FOR (2) TWO YEARS FROM DATE OF FCSA APPROVAL SHEET 1 ❑F 02 43-1(19))-20 I 43-(119))-24 JAMES T. 4 JES51E S. WILQ I WALTER S. 4 BETTY A. WILSON Q D.B. 595 PG. 409 D•B. 145 PG. 31 ZONED: MI ZONED: MI USE: COMMERCIAL USE: COMMERCIAL I N 49°30 32II E 660.001 � I , • I :+,,-' ;,A:i�w.,„•�,,.xF°,.;,. ('y",,,t1 ' '>..+''�,w-,M„,�.�, -e,'y'Fr. "we-r+'a.S. q^k"'y,fiyt-'M,k,,.*. ,, ,,,„„,�;�.7.r.,,r��,�& .,:4�,`,'��:n.,,�z�i�,�'h,. �"ww-.k. P,a \^�^"j' � h���,'r'.,am, l „; �e,Aam'*J,¢.�'�` • �r,•''.,,p!1,•_,q,;�j,'py waey � '' a( �«.�J.tr.. :F�'L�^.,.u<�,j"'�f,#,,,s�{.�4,$'^. g*.+.n._.f' .q`A �.'} i1`+l:.fi�/�•n°�.",,,•'��g,'^w' `.`.em"k.�SS"•.�'9.'"�}'�' `.'t,:e '><k„aSrV g",",+.�,^1,.' ,+j ,�afi�� "+...+?'K/ •�,°6?�"k ",,,+,F, i'v�� *.^,ti,.>"°fig1`'�,•y. ,3:Y., kLu,ba.i Tl= yT°h FB""wI.°°.��; ;,d-t ,41,:ra""�".".p;.f,.1fl t R..,' F, d4.�•w,'}�A "'u ",�(wn `(.rk)..:,A!.,�' h g"d�-.'�.r.,„. •M'ttl",,era..�.�� "h.„•) ri.&, kN 40"29'28" W-13.31'oFki s q g „ k fk k d 4 K WINCHESTER CASKET CO. O 1{ __. _ .» _.- .. • ,.. ___ - , a `Y`C�%'f - _ _- _ _ �_ /� a. - ZONED: MI USE: COMMERCIAL w Nei ;S - t \ X •�i r li �,� ✓ r� _ .- , lu _-.. r �_�,,,�,,,-.,,....,.,. c,�,.v+�,a .�v,..4 .�,�„W. sF..>+�.- <»�-,,:F» a::•.,«,.•<., ..«:+..�,.�r. ._,.a-.,.. :>w~:� .•«i ' �4 „1 'r'' ?� �01%."•I �a:.�OL i >s j w- I ! 1 _ _.- - ,_/. I { ' 1 ujul, 3ul { !il 1 ` q inn I ` v 1 t i,a F,- �.1 r . ✓� ` � V I � wemzsetiv ♦+a r xw:r r 1' � 9 I � ' � ..` I : E wm l 4 , p j l { _. ._•--.___._.__.-.. ,.a C. E 4.. ,'/�':.B- R,Il.r .4 Il...✓N S,-4.Oi x _ "1 LO xs O��r^ 14 i Lo 77 1.. PROP. U/Cz �• 11 P\ PROP. RELOCATED POWER SERVICE "<cn t FENCE CsATE ' '�£ x 1' r , t a' 1 PROP. EW 5TRIFNN6 415.4 i 1 OVERHEAD DOOR S -- PROP. 3/ WAT�R SERVICE a 1 ?G,( #, 09 EX. 7 08 43 1119)) 30 , ALLEN R. KNOTTS, SR ZONED: MI �a4T USE: MINI STORAGE \ PROP. 2" PVC 3' DOOR FORCE SEWER 1 LINE PROP. WAREHOUSE BJILD INCH PROP. 12'x12' DUMPSTER l 1,200 S.F. f PAD AND /'APRON I FF = -110.25 rg ,.!Cali•.,,.. I.b.-- _._ a..e�`'�., +.+ir r._.I �� .y �� '! ,� I �'.n 4 ilk i TO it T�J w SCREENING FENCE i e ` _ ! 11 120' . r( J x f ._— 44 _ ,. SOS EX. ! N :. � � �VF-5) _ . `� ..__ . _.... . __.. .�..__. ,__..._; k h +r k f ka• k � � tr ��,�k����•; _.e#,..�__ ,_,.,_��._.��.�,-�,,�,;:�,...�,°•- -.,��F �' '"� '�,s•' A" ' .J �*.. '4. ''• a r-+n "' ,p ",s-" F���• r....---..�___-__ ___�.-- _. ��y��•'��.,M+`/'q� "`'P""''--�Jr� ,,n� ._.s nr� ;:,•t: �, � - '4 + { ?.,,,,s!- '�d'� °.4..r�' 'a:.w` t °� a � k + �` � ` ...F �✓" ,. „ j',,. .,.e� Rom,... •w.' , 1 } - .. �. �^' ..a °-..* "- H ,...,....... + i.-. E✓,.. .,.�0 ✓ iliH, I", C." t Mini 'C-T S 49'30'32" W 660.00' \ NOTE: \ EX. WHITE PINE SGREENIN& TREES IN POOR CONDITION WILL NEED TO BE REPLAGED LENOIR CITY CO DURING SITE DEVELOPMENT. Q� i D.B. 344 PG. 235 ZONED: MI USE: VACANT 1"X4"X4'-8" SLATS, 2-FINISH NAIL AT TOP AND BOTTOM 2"X4"X4' BEAMS, TOE NAIL TO POST 4"X4"X8' POSTS 12511 /1, NOTES: I. PRESERVATIVE STAIN ON ALL WOOD. XA COLOR TO MATCH THAT OF BLDG.I I e 2. FINISHED SIDE OF FENCE SHALL FACE I ADJOINING PROPERTY, IF APPLICABLE. o _ CONC. — =M=M = i IN- UJOOD FENCE DETAIL FOR DUI" Ii=5TER ENCL05URE NOT TO SCALE Z cc W W Z Z Wcu o CQ in co CQ a a� �d N Cc ' to O 1 tow Z x' W � �� � W ° ��-�-11O Uto C14 a� to E-- 44 ca V) Q) O y w co w lfl F-- z W z � o O w z > z v Q NWr, Q O c 43-((19))-IA > RITE AID OF VIRGINIA, INC. � Lu D.B. 801 F G. 281 0- tL ZONED: MI USE: COMMERCIAL W o In �-' MARK D, H v N/fo.022837 'U SIGNAL I I SII WIRE MESH REINFORCING V.D.O.T. ROAD AND BRIDGE STANDARDS SECTION 301.04 CLASS A-3 CONCRETE .\.�\\✓�\�\�\.�\.a\.�\.�\.�\✓�\✓�\✓�\.�\✓�\.� 6" BASE 21-4 COMPACTED SUBGRADE (COMPACTED TO 135% DENSITY AT OPTIMUM MOISTURE CONTENT, VDOT VTM-I METHOD) TR45� DL 1" f=eTER fi ,4D (NOT TO SCALE) Dt-dumppad rO I--1--I � I� Oa. W � � U) � �O w0 Q 4 C/1 Q QO, O 04, V) DATE: 04/22/02 1 SCALE: 1"=30' DESIGNED BY: AS FILE NO. 0617 SHEET 02 OF 02 04 -„ [u u) 0 co 0 v N of 0 N O 0 0 0 U r; m a� CO Z Ix w F_ CO W m 0 Cn a� 0 M GENERAL NOTES VDT GENERAL NOTES LEGEND VICINITY MAP CC'3 Z_ 1. Methods and materials used in the construction of the improvements herein shall conform to the current V1. All work on this project shall conform to the latest editions of the Virginia Department of Transportation (VDOT) Road and Bridge Specifications and Standards, the Virginia Erosion and EXISTING INTERMEDIATE CONTOUR a- w -" "" "` SCALE: �� = I2��� Count construction standards and specifications and/or current VDOT standards and specifications. y p / P Sediment Control Regulations and any other state, federal or local regulations applicable. In the 330 � event of conflict between any of these standards, specifications or plans, the most stringent shall be EXISTING INDEX CONTOUR 2. Measures to control erosion and siltation, including detention ponds serving as silt basins during construction, govern. 40 W must be provided prior to issuance of the site development permit. The approval of these plans in no way PROPOSED CONTOUR EX �'.- ��` relieves the developer or his agent of the responsibilities contained in the Virginia Erosion and Sediment V2. All construction shall comply with the latest U.S. Department of Labor, Occupational Safety and EXISTING EDGE OF PAVEMENT ---- -u-W _ Control Handbook. Health Administration and VOSH Rules and Regulations. PROPOSED EDGE OF PAVEMENT PROP E/P ZJI In `� "Q�' 3. A permit must be obtained from the Office of the Resident Engineer, Virginia Department of Transportation V3. When working on VDOT right-of-way, all traffic control, whether permanent or temporary, shall EXISTING CURB AND GUTTER E C415 _ _ _._ ---- ----- --- - --- - ---- -- - - - - ,� �� �� Z (VDOT) and Frederick County prior to construction in existing State right-of-way. be in accordance with the current edition of VDOT's work area protection manual. Furthermore, all traffic control flaggers must be certified in accordance with the latest edition of the VDOT Road and PROP C&G W N 4. Approval of this plan does not guarantee issuance of an entrance permit by VDOT when such permit is Bridge Specifications, Section 104.04-C. PROPOSED CURB AND GUTTER :,.. G CD required under State law. V4. The developer be for his including TRANSITION FROM CG-6 TO CG-6R - - o0 v 5. The exact location of all guard rails will be determined by VDOT personnel. "A joint inspection will be held with the Developer, County Representatives, and Representatives of the Virginia Department of Transportation shall responsible relocating, at expense, any and all utilities, traffic signal poles, junction boxes, controllers, etc. owned by VDOT or private utility company. It is the sole responsibility of the developer to locate and identify utility facilities or items, which may EXISTING TELEPHONE LINE - -- --- -- - -- �____ .__ _ __ __ ___ ._ ____ _ �_ ._.. _ -.__ ��V �1 !i� o � co (VDOT) to determine if and where guard rail and/of paved ditches will be needed. The developer will be be in conflict with the proposed construction activity. VDOT approval of these plans does not 0 i � 01 in by this inspection." Refer to PROPOSED TELEPHONE LINE T 11 U..'S J o aN responsible for providing guardrail and paved ditches as determined joint relieve the developer of this responsibility. -RTE" j Virginia Department of Transportation (VDOT) Guard Rail and Paved Ditch Specifications. EXISTING STORM SEVER _�_ __ -_- �- -�- F-�-�---.-�-- Z - = in OJ N 6. An approved set of plans and all applicable permits must be available at the construction site. Also, a V5. Design features relating to field construction, regulations, and control or safety of traffic may be subject to change as deemed necessary by VDOT. Any additional expense incurred as a result of PROP. 15 RGP L _W n, � representative of the developer must be available at all times. any field revision will be the responsibility of the developer. PROPOSED STORM SEWER _ ■ N W C o 0 qT 7. Warning signs, markers, barricades or flagmen should be in accordance with the Manual on Uniform Traffic V6. Prior to initiation of work, the contractor shall be responsible for acquiring all necessary VDOT EXISTING SANITARY SEWER W S Ln O x Control Devices (MUTCD). land use permits for any work on VDOT right-of-way. PROPOSED SANITARY SEWER PROJECT INFORMATION Ln 3 < 8. All unsuitable material shall be removed from the construction limits of the roadway before placing V7. If required by the local VDOT Residency Office, a pre -construction conference must be arranged EXISTING ELECTRIC SERVICE 9. embankment. All pavement sections on the approved plans are minimum sections to be utilized when the actual California and held by the engineer and/or developer with the attendance of the contractor, various County agencies, utility companies and VDOT prior to initiation of work. PROPOSED ELECTRIC SERVICE EX STREET ADDRESS 240 McGHEE ROAD WINCHESTER, VA 22601 ^� o 0 Bearing Ratio (CBR) of the pavement subgrade is 6 or more. Soils tests of the subgrade shall be performed V8. The contractor shall notifythe local VDOT Resident Office when work is to begin or cease for Y g° EXISTING GAS LINE for actual determination of required pavement thickness prior to placement. All final pavement and base any undetermined length of time. VDOT will also require 48 hours notice for any inspection. PARCEL IDENTIFICATION NO, 43-((19))-39 - > L course thicknesses shall be designed in accordance with VDOT's "Pavement Design Guide for Subdivision and PROPOSED GAS LINE LOT AREA 5.3185 AC. o w N Secondary Roads in Virginia", and shall be based on a sufficient number of CBR tests to determine the true The contractor will bresponsible for maintaining adequate access to the project from the DISTURBED AREA 7,200 S.F. support values of the soils in the subgrade. Final pavement design shall be submitted during construction t hroughconstruction and maintenance of a construction entrance in adjacent public roadway t adj accordance with the Virginia Erosion and Sediment Control Handbook, Section 3.02. Furthermore, PROPERTY LINE CURRENT ZONING M 1 and prior to placement. P P access to other properties affected b this project shall be maintained through construction. The P P Y P J g"-. FLOW LINE -► --- --�- ---- ... -d---" CURRENT USE MANUFACTURING /WAREHOUSE 10. All roadside ditches at grades of more than 5% shall be paved with cement concrete to the limits indicated Developer shall have, within the limits of the project, an employee certified by the Department, of Conservation and Recreation in Erosion and Sediment Control who shall inspect erosion and siltation FENCEL[NE PROPOSED USE MANUFACTURING / WAREHOUSE on the plans and as required at the field 'inspection. control devices and measures for proper installation and deficiencies immediately after each rainfall, EXISTING POWER POLE BUILDING HEIGHT: MAXIMUM ALLOWED = 60' PROPOSED = 16' 11. All springs shall be capped and piped to the nearest storm sewer manholes or curb inlet. The pipe shall at lest daily during prolonged rainfall, and weekly when no rainfall event occurs. -�� SIGNS: ALL SIGNAGE MUST CONFORM WITH THE be minimum 6" diameter and conform to VDOT standard SB-1. V10. Contractor shall ensure adequate drainage is achieved and maintained on the site during and EXISTING TELEPHONE POLE �..,1 STANDARDS OF SECTION 165-30 OF at the end of construction. EXISTING WATERLINE W/ TEE - THE FREDERICK COUNTY ZONING ORDINANCE. 12. Construction debris shall be containerized in accordance with the Virginia Litter Control Act; no less than OUTDOOR LIGHTING: EX. OUTDOOR LIGHTING FIXTURES one litter receptacle shall be provided at the construction site. P P Vll. All water and sewer lines within existing or proposed VDOT right-of-way are to have minimum PROPOSED WATERLINE W/ TEE 13. The contractor shall provide adequate means of cleaning mud from trucks and/or other equipment prior to 36" cover and, when possible, to be installed under roadway drainage facilities. BUILDING SETBACKS: REQUIRED: FRONT: 75° PROPOSED: FRONT: 1 1 1.1' SIDE: 25 SIDE: 26 , 259.8 entering public streets, and it is the contractors responsibility to clean streets, allay dust, and to take V12. Any unusual subsurface conditions encountered during the course of construction shall be EXISTING FIRE HYDRANT REAR: 25' REAR: 418.4' whatever measures are necessary to insure that the streets are maintained in a clean, mud and dust free immediately brought to the attention of the engineer and VDOT. Work shall cease in that vicinity EXISTING WATER VALVE condition at all times. until an adequate design can be determined by the engineer and approved by VDOT. 14. * Notification shall be given to the appropriate utility company prior to construction of water and/or sanitary V13. All fill areas, borrow material and undercut areas shall be inspected and approved by a VDOT PROPOSED WATER METER PARKING CALCULATIONS LANDSCAPED AREA REQUIRED sewer lines. Information should also be obtained from the appropriate authority concerning permits, cut representative prior to placement and fill. Where CBR testing is required, a VDOT representative P P P g q � P EXISTING REDUCER REQUIRED 25% = 57,918 S.F. sheets, and connections to existing lines, shall be present to insure the sample obtained is representative of the location. When soil samples PROPOSED REDUCER OFFICE = 1 SPACE PER 250 S.F. (NO LANDSCAPED AREA LOST DUE TO PROP, BLDG.) 15. All sanitary sewers and water mains and appurtenances shall be constructed in accordance with the current are submitted to private laboratories for testing, the samples shall be clearly identified and labeled as belonging to a which will be accepted by VDOT and that testing shall be conducted STOP SIGN WAREHOUSE = 1 SPACE PER EX. BUILDINGS = 13,200 S.F. EMPLOYEE ' standards and specifications of Frederick County and/or the Frederick County Sanitation Authority. project according to all applicable VDOT standards. FABRICATION = 3 SPACES PER EMPLOYEE EX. PAVED & GRAVEL AREA = 147.900 S.F. p� HANDICAP RAMP {CG-12) a J�.!�' TOTAL = 161,100 S.F. o 16. The location of existing utilities shown in these plans are taken from existing records. It shall be the contractors responsibility to verify the exact horizontal and vertical location of all existing utilities as needed g V14. All roadway fill, base, subsurface material and backfill of utility/storm sewer trenches shall be DENOTES LOCATION OF STD VDOT CG-12 AND/OR JUR[SDtt��IO��A 231,674 S.F. - 161,100 S.F. = 70,574 S.F. �+ E- U P Y Y to The contractor shall inform the engineer of any conflicts arising from his existing compacted in 6" lifts to 95% of theoretical maximum density as determined by AASHTO T-99 Method STANDARD RAMP CONSTRUCT[0� EX. OFFICE = 1,000 S.F. = 4 SPACES 70,574 S.F. / 231,674 S.F. = 31 % F--� prior construction. A, within plus or minus 2� of optimum moisture for the full width of an dedicated street P P Y PARKING INDICATOR t2 EX. WAREHOUSE = 0 EMPLOYEES utilityverification and the proposed construction. P P right-of-way. At the direction of VDOT Inspector, density tests performed by a qualified INDICATES THE NUMBER OF TYPICAL PARKING SPACES EX. FABRICATION = 8 EMPLOYEES = 6 SPACES Z E" Z 17. The developer will be responsible for any damage to the existing streets and utilities which occurs as a independent agency shall be conducted as required in the VDOT Road and Bridge Specifications. A copy of all tests shall be submitted to VDOT prior to final VDOT approval. Q a U) result of his construction project within or contiguous to the existing right-of-way. TEST PIT LOCATION � 18. When grading is proposed within easements of utilities, letters of permission from all involved companies g g P P to Frederick County Sanitation Authority to issuance of and/or site V15. VDOT Standard CD and UD under -drains shall be installed where indicated on these plans and further where determined necessary ector. VDOT Ins by p. TOTAL SPACES REQUIRED TOTAL EXISTING SPACES = 10 F.A.R. = 2.4 EX. BUILDINGSS.F. � must be provided prior grading HANDICAP PARKING =13,200 development permits. V16. The installation of any entrances and mailboxes within any dedicated street right-of-way shall EX. SPACES LOST DUE TO - PROP. BUILDING 7,200 S.F. x W Q; >, E 19. The developer will be responsible for the relocation of any utilities which is required as a result of his meet VDOT minimum design standards and is the responsibility of the developer. VEHICLES PER DAY COUNT 100 PROPOSED BUILDING = 4 TOTAL = 20,400 S.F. 20,400 S.F. / 231,674 S.F. = 0.088 co - (� E-- Z project. The relocation should be done prior to construction. V17. Prior to acceptance by VDOT of any streets, any required street signage and/or pavement PROPOSED BUILDING ENTRANCE TOTAL REMAINING SPACES = 20 � Z O OO �D 20. These plans identify the location of all known gravesites. Gravesites shown on this plan will be protected markings must be installed by the developer or at VDOT's discretion, by VDOT on an account NO ADDITIONAL EMPLOYEES ARE PROPOSED x in accordance with state law. In the event gravesites are discovered during construction, the owner and receivable basis. Stop signs shall be thirty (30) inches tall with high intensity sheeting. The , ENVIRONMENTAL FEATURES W a'- engineer must be notified immediately. bottom of the sign shall be six (6) feet above the edge of pavement and the post shall be installed a minimum of four (4) feet from the edge of pavement. Sign posts shall be of a type found on EXISTING STREET LIGHT ' HANDICAP PARKING FEATURE EX. ACREAGE 04 � W W � 21. The contractor is to verify field conditions prior to and during construction and notify Greenway Engineering 662-4185 immediately discrepancies between field conditions and the approved VDOT's approved list. A co of this list may be obtained from the District Material Section. PP PY Y Contact the local VDOT Residency Office with any questions regarding sign material and placement. PROPOSED STREET NAME SIGN -�- 1 -25 = 1 SPACE REQUIRED FLOODPLAINS 0 EX. HANDICAP SPACES = 1 LAKES & PONDS 0 E-- �' (�, f at (540) of any actual plan. � � W "A" V18. The developer must to the local VDOT office a list of all material sources to PROPOSED SANITARY LATERAL CLEANOUT WETLANDS PL 1 AC. 0 �1 � W Q 22. Controlled fills shall be compacted to 95% of maximum density as determined by method per standard provide prior P P P construction. Copies of all invoices for materials within any dedicated street right-of-way must be SANITARY MANHOLE IDENTIFIER 12 LOADING SPACES SINKHOLES 0 NATURAL STORM 0O W W proctor AASHTO-T99, ASTM-D698, or VTM-1 as applicable. Density shall be certified by a registered provided to the local VDOT Residency Office prior to acceptance of the work. Unit and total prices WATER O < � professional engineer and results submitted to Frederick County prior to pavement construction. If a be REQUIRED: 1 PER 40,000 S.F. OF FLOOR AREA DETENTION AREAS 0 report has been prepared, it should supersede the requirements in this note. may obscured. STORM DRAIN STRUCTURE IDENTIFIER 0 TOTAL FLOOR AREA = 20,400 S.F. STEEP SLOPES PL 15% 0 SPACES REQUIRED = 1 WOODLANDS 0 Q.geotechnical 0 0 E 0O V19. Aggregate bases and sub -bases shall be placed on the sub -grade by means of a mechanical � 23. Contractors shall notify operators who maintain underground utility lines in the area of proposed excavating spreader. Density will be determined using the density control strip as specified in VDOT's Road and SPACES PROVIDED = 2 a or blasting at least two (2) working days, but not more than ten (10) working days, prior to commencement Bridge Specifications -Section 304 and VTM-10. A certified compaction technician shall perform these EASEMENT LINE of excavation or demolition. Names and telephone numbers of the and operators underground utility lines tests. A certified copy of the test results shall be provided to the Residency Office. In additions to PREVIOUS APPROVED PLAN #66-99 in Frederick County appear below. These numbers shall also be used to serve in an emergency condition. checking stone depths, a VDOT representative shall be notified and given the opportunity to be CENTERLINE present during the construction and testing of the density control strip. !"'`"y MJ EXISTING SPOT ELEVATION TRIP GENERATION DATA UTILITYCONTACTS V20. Asphalt concrete pavement shall be placed in accordance with the latest edition of VDOT's Road + CLASS USE S.F. EMPLOYEES TRIP RATE USE VPD and Bridge Specifications -Section 315. Density will be determined using the density control strip as specified in Section 315 and VTM-76. A certified compaction technician shall perform these tests. PROPOSED SPOT ELEVATION ll_`i 3 Water/Sewer: Frederick County Sanitation Authority Gas: Shenandoah Gas Co. A certified copy of the test results shall be provided to the Residency Office. A VDOT representative EXISTING TREE LINE P.O. Box 1877 P.O. Box 2400 Winchester, VA. 22604 Winchester, VA 22604 shall be notified and given the opportunity to be present during the construction and testing of the control strip. EXISTING TREE '"° c; � 140 MANUFACTURING 6000 5 2.0 / EMPLOYEE / 1000 S.F. 10 23 (540) 868-1061 (540) 869-1111 Irk° OAK ;�, PINE3.8 V21. Approval of these plans shall expire three (3) years from the date of the approval letter. Power: Allegheny Power Phone: Verizon P.O. Box 1458 V22, Final location of CG-12 Curb Ramps shall be determined by VDOT inspector. PROPOSED TREE r.. fro-, 150 OAK 15 PINE P.O. Box 17398 Hagerstown, MD 21741 Baltimore, MD 21297 TOTAL 33 i-800-654-3317 (301) 954-6282 TICSA CONJRUCTOA NOTES MISS UTILITY 1-800-257-7777 1. WATER AND SEWER LINES ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THESE PLANS. THE LINES SHALL ADDITIONALLY MEET ALL REQUIREMENTS OF THE FREDERICK COUNTY SANITATION AUTHORITY, DATE REVISION SEAL C®VER SHEET �r FIRE MARSHALL Pal NOTE 2. THE CONTRACTOR SHALL COORDINATE WITH, AND ARRANGE FOR INSPECTION BY THE AUTHORITY. ' ' 3. EXACT LOCATIONS OF WATER AND SEWER SERVICES ARE TO BE COORDINATED WITH THE AUTHORITY'S INSPECTOR. 5/29/02 PER V.D.O.T. COMMENTS Project Name: EASTERN SUPPLY 8/I/02 FRED. G0. PLANNING COMMENTS FIRE LANE MARKINGS AND SIGNAGE Any Parking" signs and yellow painted curb 4. THE SANITATION AUTHORITY'S MAINTENANCE DEPARTMENT IS RESPONSIBLE FOR THE INSTALLATION OF locations will be installed by field inspection at ion WATER METERS THROUGH 2" IN SIZE. BEFORE A PERMANENT METER IS SET, THEY REQUIRE: 1) THE FRAME Owner: Address, Including Zip Code &Telephone No. the direction of the Fire Marshall's office. AND COVER TO BE PROPERLY ALIGNED WITH ITS METER BOX AND YOKE BAR; 2) THE FRAME AND COVER TO r BE SET TO THE FINAL GRADE OF THE LOT; 3) THE DISTANCE BETWEEN THE TOP OF THE COVER AND YOKE 195 EBERT ROAD (P.O. BOX 1445) BAR BE BETWEEN 18 AND 21 INCHES; AND 4) ALL COMPONENTS OF THE METER BOX ASSEMBLY TO BE IN MAR D. S H T.S.M., INC. WINCHESTER, VA 22604 PROPER WORKING ORDER. IT IS THE DEVELOPER'S/CONTRACTOR'S RESPONSIBILITY TO HAVE THE METER BOX ASSEMBLY INSTALLED CORRECTLY. "0 N0, 022837 0 �C�'�, �` �� U (540) 722-3292 p® D,� Developer: Address, Including Zip Code & Telephone No. �G E S' NARRA I VEi 5. FOR WATER AND SEWER SERVICES THAT CONNECT TO EXISTING LINES: �yti 195 EBERT ROAD (P.O. BOX 1445) A. THE LOCATION OF THE SERVICE LATERAL IS TO BE COORDINATED WITH THE AUTHORITY'S ENGINEERING ASSISTANT. AN APPLICATION FOR SERVICE MUST BE MADE AND FEES PAID BEFORE WORK WILL BEGIN. S' IoNAL EASTERN SUPPLY , WINCHESTER, VA 22604 't �'' (540) 722-3292 SHEET INDEX `j Project Description B. THE AUTHORITY SHALL FURNISH AND INSTALL ALL 5/8" , 3/4" AND 1" WATER SERVICES. Engineer Certifying Plan: BUGr � Address, Includin ZipCode 00� Sc Telephone hone No. The purpose of this project is for the construction of a 7,200 S. F. storage building. C. FOR ALL 1 1/2" AND 2" WATER SERVICES, THE AUTHORITY SHALL MAKE THE TAP AND BRING THE PIPING TO THE PROPERTY LINE. THE CONTRACTOR IS TO FURNISH & INSTALL THE METER VAULT ASSEMBLY. 151 WINDY HILL LANE Adjacent Pro erties THE AUTHORITY WILL INSTALL THE METER. D. THE AUTHORITY WILL INSTALL ALL SEWER LATERALS. GREENWAY ENGINEERING WINCHESTER, VA 22602 The adjacent properties are owned by James and Jessie Wilson, Lenoir City Co., and Rite Aid of Virginia, Inc. (540) 662-4185 PROFESSIONAL SEAL & SIGNATURE 6. WHEN AN EXISTING WATER MAIN IS TAPPED FOR THE INSTALLATION OF A NEW LINE: COVER SHEET SHEET 1 a - L �...ATOF14 Erosion Control Program A. THE AUTHORITY SHALL FURNISH ALL LABOR AND MATERIALS TO MAKE THE TAP. SITE PLAN SHEET 2 DATE: 04/24/02 Install silt fence B. THE DEVELOPER/CONTRACTOR MUST: 1) MAKE APPLICATION FOR THE TAP, 2) PAY DEPOSIT (BEFORE WORK BEGINS); 3) MARK THE LOCATION OF THE TAP; AND 4) MAKE FINAL PAYMENT WHEN THE WORK IS THESE PLANS ARE IN CONFORMANCE WITH APPROVAL PHI ��'ED ffiAT a° ' SCALE- Maintenance Program 1. The contractor will inspect all erosion and sediment control measures after each rainfall and at least COMPLETED. COUNTY OF FREDERICK STANDARDS AND ORDINANCES. ANY DEVIATION OR CHANGE .- N/A daily during Damaged and/or deficient areas will be repaired or improved immediately 7. THE CONTRACTOR SHALL TIE-IN A NEW LINE TO AN EXISTING MANHOLE BY CORE DRILLING THE MANHOLE. IN THESE PLANS SHALL BE APPROVED BY ` �� l (� DESIGNED B Y : prolonged rainfall. 8. WATER SERVICE LINE MUST HAVE A DOUBLE CHECK VALVE OR RPZ BACKFLOW PREVENTION 2. Furthermore, the contractor will make a dailyreview of areas of construction activityto insure erosion ANY THE ZONING ADMINISTRATOR PRIOR TO AS control effectiveness. Additional measures will be installed immediate) where deficiencies are found. 3' ASSEMBLY, AS REQUIRED, INSTALLED. THE ASSEMBLY SHALL MEET ASSE STANDARD No. 1015 OR 1013. A CONSTRUCTION. FREDERICK COUNTY ZONING ADMINISTRATOR DATE REMOTE READOUT IS REQUIRED. 3. Permanent erosion control measures include the establishment of grass on exposed surfaces disturbed 9. ALL FIRE LINES SHALL HAVE A DETECTOR DOUBLE CHECK VALVE BACKFLOW PREVENTION ASSEMBLY OR A JOB N❑. 0617 in the construction process, excluding the road surface. RPZ BACKFLOW ASSEMBLY AS REQUIRED. THE ASSEMBLY SHALL MEET ASSE STANDARD No. 1048 OR 1047. *SITE PLAN VALID FOR (5) FIVE YEARS FROM DATE OF PLANNING DEPT APPROVAL A REMOTE READOUT IS REQUIRED. * SITE PLAN VALID FOR (2) TWO YEARS FROM DATE OF FCSA APPROVAL SHEET 1 OF 02 Z W U) Q W m 0 V) O w 0