Loading...
HomeMy WebLinkAbout18-02 Hunting Ridge Cell Tower - Gainesboro - BackfileK4 VICINITY MAP ..._ GENERAL NOTES VD0T GENERAL NOTES LEGEND SCALE 1 = 2000 Vl. All work on this project shall conform to the latest editions of the Virginia Department of -..... Transportation (VDOT) Road and Bridge Specifications and Standards, the Virginia Erosion and EXISTING INTERMEDIATE CONT�;�,rrL `'- ro 4 , 1. Methods and materials used in the construction of the improvements herein shall conform to the current Sediment Control Regulations and any other state, federal or local regulations applicable. In the EXISTING INDEX CONTOUR tx3i? �° ! i `; '., } ` ` ', '-�•'. LLJ event of conflict between any of these standards, specifications or plans, the most stringent shall be y� / � ;� / , _ County construction standards and specifications and/or current VDOT standards and specifications. govern. 40 l ----. - _,' ' `' PROPOSED CONTOUR �'r '�� 2. Measures to control erosion and siltation, including detention ponds serving as silt basins during construction, V2. All construction shall comply with the latest U.S. Department of Labor, Occupational Safety and P Y P P Y EXISTING EDGE OF PAVEMENT must be provided prior to issuance of the site development permit. The approval of these plans in no way Health Administration and VOSH Rules and Regulations. PROP E P /;a relieves the developer or his agent of the responsibilities contained in the Virginia Siltation and Erosion PROPOSED EDGE OF PAVEMENT � Control Handbook. V3. When working on VDOT right-of-way, all traffic control, whether permanent or temporary, shall EXISTING CURB AND GUTTER ;��:;Fci 1' ' Z 3. A permit must be obtained from the Office of the Resident Engineer, Virginia Department of Transportation be in accordance with the current edition of VDOT's work area protection manual. Furthermore, all traffic control flaggers must be certified in accordance with the latest edition of the VDOT Road and PROP C&G ` UJ (VDOT) and Frederick County prior to construction in existing State right-of-way. 4. Approval of this plan does not guarantee issuance of an entrance permit by VDOT when such permit is Bridge Specifications, Section 104.04-C. PROPOSED CURB AND GUTTER CG-6 0 CG-6R t , ; _ / ' j s 00 V4. The developer shall be responsible for relocating, at his x ense, anand all utilities, including P P g' P Y g TRANSITION FROM CG-6 TO CG''-6R { required under State law. q 5. The exact location of all guard rails will be determined by VDOT personnel. "A joint inspection will be held traffic signal poles, 'unction boxes, controllers, etc. owned b VDOT or private utilitycompany. It is Y • the sole responsibility of the developer to locate and identify utility facilities or items, which may be in conflict with the proposed construction activity. VDOT approval of these plans does not EXISTING TELEPHONE LINE .._._.._.._...,.___._...-_...___._.�.._____._ LINE _.___._._.....__._...__.-.__.__... 41 �, ._ � � -.,� ;�% ,; ," � •� � ago with the Developer, Count Representatives, and Representatives of the Virginia Department of Transportation P Y P P g P P PROPOSED TELEPHONE (VDOT) to determine if and where guard rail and/of paved ditches w111 be needed. The developer will be relieve the developer of this responsibility. r it,�. 1��„ PEA �4�' / � •� c� responsible for providing guardrail and paved ditches as determined by this joint inspection. Refer to V5. Design features relating to field construction, regulations, and control or safety of traffic may g g g Y Y EXISTING STORM SEWER - - -°� " PROP. 15 RCPk,. E. ` o Virginia Department of Transportation VDOT Guard Rail and Paved Ditch Specifications. g• P P (VDOT) P be subject to change as deemed necessary b VDOT. An additional expense incurred as a result of J g Y Y Y P � � ` �; �,. � a , `'� •. ,� b .1 W I p any field revision will be the responsibility of the developer. PROPOSED STORM SEWER r. ! i' o 6. An approved set of plans and all applicable permits must be available at the construction site. Also, a a`� �;r!f I /`YcIE i; a►n representative of the developer must be available at all times. re P P V6. Prior to initiation of work, the contractor shall be responsible for acquiring all necessary VDOT EXISTING SANITARY SEWER ", 7. Warningsigns, markers, barricades or flagmen should be in accordance with the Manual on Uniform Traffic land use permits for any work on VDOT right-of-way. PROPOSED SANITARY SEWER �r �� .,.; tr l�j2Z Control Devices (MUTCD). V7. If required by the local VDOT Residency Office, a pre -construction conference must be arranged EXISTING ELECTRIC SERVICE -----'______.__-.___....__-_.__._.._.______.___.._____._.. //i' // 8. All unsuitable material shall be removed from the construction limits of the roadway before placing and held by the engineer and/or developer with the attendance of the contractor, various County agencies, utility companies and VDOT prior to initiation of work. PROPOSED ELECTRIC SERVICE a� s~ �• 0 embankment. PROJECT INFORMATION ai 9. less V8. The contractor shall notify the local VDOT Residency Office when work is to begin or cease for EXISTING GAS LINE _.-_._.._-_______.__ ..-_.-__..._��-___..___-._.._.._._..____._.___.-__._..___... All pavement sections on the approved plans are based on a minimum CBR value of 6. CBR values than 6 will require revised pavement section prepared by Greenway Engineering and approved by the owner. any undetermined length of time. VDOT will also require 48 hours notice for any inspection. PROPOSED GAS LINE w PARCEL IDENTIFICATION: PIN # 30A-98C � 10. All roadside ditches at grades of more than 5% shall be paved with cement concrete to the limits indicated V9. The contractor will be responsible for maintaining adequate access to the project from the w on the plans and as required at the field inspection. P q P adjacent public roadway through construction and maintenance of a construction entrance in PROPERTY LINE-��-----�- ----------- CURRENT ZONING: RA SETBACKS: REQUIRED: PROPOSED: accordance with the Virginia Erosion and Sediment Control Handbook, Section 3.02. Furthermore, FRONT: 220' FRONT: 835' 11. All springs shall be capped and piped to the nearest storm sewer manholes or curb inlet. The pipe shall access to other properties affected by this project shall be maintained through construction. The FLOW LINE - - - - -� -- '- CURRENT USE: VACANT SIDE: 210' SIDE: 627 be minimum 6 diameter and conform to VDOT standard SB-1. Developer shall have„ within the limits of the project, an employee certified b the Department of P P JY P Conservation and Recreation 1n Erosion and Sediment Control who shall inspect erosion and siltation FENCELINE --... - }---___ �.... k__.__ _ K-__._._...___._ ____ � PROPOSED USE: UNMANNED COMMUNICATION FACILITY ' REAR: 210 REAR: 211 12. Construction debris shall be containerized in accordance with the Virginia Litter Control Act; no less than control devices and measures for proper installation and deficiencies immediately after each rainfall, EXISTING POWER POLE {._,) CQ C-1 one litter receptacle shall be provided at the construction site. at lest daily during prolonged rainfall, and weekly when no rainfall event occurs. , SITE AREA: 35.0 AC OUTDOOR LIGHTING: NONE SPECIFIED � CQ EXISTING TELEPHONE POLE 0 DISTURBED AREA: 20,000 SF OUTDOOR STORAGE: NONE SPECIFIED n 13. The contractor shall provide adequate means of cleaning mud from trucks and/or other equipment prior to V10. Contractor shall. ensure adequate drainage is achieved and maintained on the site during and LEASE AREA: 10,000 SF o 0 entering public streets, and it is the contractors responsibility to clean streets, allay dust, and to take at the end of construction. EXISTING WATERLINE W� TEE�--�~�~Ca whatever measures are necessary to insure that the streets are maintained in a clean, mud and dust free condition at all times. Vll. All water and sewer lines within existing or proposed VDOT right-of-way are to have minimum g P P g Y PROPOSED WATERLINE W TEE Ti ENVIRONMENTAL FEATURES: EXISTING IRRIGATION POND WILL NOT BE Z q r. 36" cover and, when possible, to be installed under roadway drainage facilities. PROPOSED FIRE HYDRANT e$a DISTURBED WITH DEVELOPMENT OF THIS SITE. o V) o 14. Notification shall be given to the appropriate utility company prior to construction of water and/or sanitary v v sewer lines. Information should also be obtained from the appropriate authority concerning permits, cut V12. Any unusual subsurface conditions encountered during the course of construction shall be sheets, and connections to existing lines. immediately brought to the attention of the engineer and VDOT. Work shall cease in that vicinity EXISTING WATER VALVE AIR TRAFFIC CONTROL LIGHTING WILL BE Q Q until an adequate design can be determined by the engineer and approved by VDOT. PROVIDED AS REQUIRED BY REGIONAL 15. All sanitary sewers and water mains and appurtenances shall be constructed in accordance with the current PROPOSED WATER METER m AIRPORT AUTHORITY. a standards and specifications of Frederick County and/or the Frederick County Public Service Authority. V13. All fill areas, borrow material and undercut areas shall be inspected and approved by a VDOT EXISTING REDUCER representative prior to placement and fill. Where CBR testing is required, a VDOT representative 16. The location of existing utilities shown in these plans are taken from existing records. It shall be the contractors responsibility to verify the exact horizontal and vertical location of all existing utilities as needed shall be present to insure the sample obtained is representative of the location. When soil samples are submitted to private laboratories for testing, the samples shall be clearly identified and labeled P g' P Y PROPOSED REDUCER -`` ti�� cOG r 4 `la °" u a" v prior to construction. The contractor shall inform the engineer of any conflicts arising from his existing as belonging to a project which will be accepted by VDOT and that testing shall be conducted STOP SIGN COUNTY of FREDERICK A. according to all applicable VDOT standards. b utility verification and the proposed construction. VEHICLES PER DAY COUNT 100 a Department of Planning and Development 5 W 17. The developer will be responsible for any damage to the existing streets and utilities which occurs as a V14. All roadway fill, base, subsurface material and backfill of utility/storm sewer trenches shall be PROPOSED STREET NAME SIGN # 540/669-5651 ;• FAX:5401665.6395 0U x y Cr. result of his construction project within or contiguous to the existing right-of-way. compacted in 6" lifts to 95% of theoretical maximum density as determined by AASHTO T-99 Method A, within plus or minus 2% of optimum moisture for the full width of any dedicated street PROPOSED SANITARY LATERAL CLEANOUT March 3, 2002 18. When grading is proposed within easements of utilities, letters of permission from all involved companies be right-of-way. At the direction of VDOT Inspector, density tests performed by a qualified independent agency shall be conducted as required in the VDOT Road and Bridge Specifications. A SANITARY MANHOLE IDENTIFIED 12 F Q o 0 must provided to Frederick County Public Service Authority prior to issuance of grading and/or site of development permits. copy of all tests shall be submitted to VDOT prior to final VDOT approval. Mr. Kamal Doshi Shared Towers, LLC 19. The developer will be responsible for the relocation of any utilities which is required as a result of his V15. VDOT Standard BCD and UD under -drains shall be installed where indicated on these plans and STORM DRAIN STRUCTURE IDENTIFIER 6 6501 Sandy Knoll Court project. The relocation should be done prior to construction. further where determined necessary by VDOT Inspector. McLwl o, VA 22101 RE: CUP #05-02 for the Hnartinig 8idge Telecommunications facility; P.I.N. 30-A-98C 20. These plans identify the location of all known gravesites. Gravesites shown on this plan will be protected V16. The installation of any entrances and mailboxes within any dedicated street right -of -wiry shall EASEMENT LINE in accordance with state law. In the event gravesites are discovered during construction, the owner and meet VDOT minimum design standards and is the responsibility of the developer. Dear. N,r. Doshi: CENTERLINE engineer must be notified immediately. V17. Prior to acceptance by VDOT of any streets, any required street signage and/or pavement 12- This letter is to confirm action taken by the Frederick County Board of Supervisors at their meeting on March 13, 2002. Your application, Conditional Use Permit #05-02 for a 195-foot lattice -type 21. The contractor is to verify field conditions prior to and during construction and notify Greenway Engineering markings must be installed by the developer or at VDOT's discretion, by VDOT on an account EXISTING SPOT ELEVATION telecommunications tower with a waiver ofthe setbacks to the internal parcel boundary lines was approved at (540) 662-4185 immediately of any discrepancies between actual field conditions and the approved plan. receivable basis. St o si ns shall be thirt 30 inches tall with hi h intensit sheetin The P g Y ( ) g Y g PROPOSED SPOT ELEVATION + 715 s with the following conditions: bottom of the sign shall be six (6) feet above the edge of pavement and the post shall be installed 1. All Zoning Ordinance requirements andreview agency comments shallbe addressed and complied 22. Controlled fills shall be compacted to 95% of maximum density as determined by method "A" per standard a minimum of four (4) feet from the edge of pavement. Sign posts shall be of a type found on EXISTING TREE DRIP LINE j -^ r...� r'- -h-f -' - -:�^ with at all times. proctor AASHTO-T99, ASTM-D698, or VTM-1 as applicable. Density shall be certified by a registered VDOT's approved list. A copy of this list may be obtained from the District Material Section. professional engineer and results submitted to Frederick County prior to pavement construction. If a Contact the local VDOT Residency Office with any questions regarding sign material and placement. 2. The tower shall be available for co -locating personal wireless services providers. geotechnical report has been prepared, it should supersede the requirements in this note. V18. The developer must provide to the local VDOT office a list of all material sources prior to 3. A minor site plan shall be approved by the County. 23. Contractors shall notify operators who maintain underground utility lines in the area of proposed excavating construction. Copies of all invoices for materials within any dedicated street right-of-way must be 4. The tower shall be removed by the applicant or property owner within twelve (12) months of or blasting at least two (2) working days, but not more than ten (10) working days, prior to commencement provided to the local VDOT Residency Office prior to acceptance of the work. Unit and total prices abandonment of operation. may be obscured. of excavation or demolition. Names and telephone numbers of the and operators underground utility lines 5. In the event a telecommunications tower is not erected within twelve (12) months of the approval in Frederick County appear below. These numbers shall also be used to serve in an emergency condition. V19. Aggregate bases and sub -bases shall be placed on the sub -grade by means of a mechanical of this Conditional Use Permit, then the CUP will be deeded invalid. , spreader. Density will be determined using the density control strip as specified in VDOT's Road and 6. Issuance of CUP#05-02shallmake the Conditional Use Permit(CUP#19-01)previouslyissuedfor Bride Specifications- 304 and VTM-10. A certified compaction technician shall P p perform these an adjoining property (same property owner) invalid - tests. tests. A certified copy of the test results shall be provided to the Residency Office. In additions to If you have any questions regarding this action or the site plan approval process, please feel free to call this checking stone depths, a VDOT representative shall be notified and given the opportunity to be office. present during the construction and testing of the density control strip. V20. Asphalt concrete pavement shall be placed in accordance with the latest edition of VDOT's Road --- , Si1.emn and Bridge Specifications -Section 315. Density will be determined using the density control strip as in Section 315 VTM-76. ,_ , specified and A certified compaction technician shall perform these tests. A certified copy of the test results shall be to the Residency Office. A VDOT Eawrce AICP, CZA W � provided representative Deputy Director Q E- shall be notified and given the opportunity to be present during the construction and testing of the � control strip. ERL/ch cc: Mark Smith, Greenway Engineering i� Z O FCSA CONSTRUCTION NOTES V21. Approval of these plans shall expire three (3) years from the date of the approval letter. L� , Sidney Reyes, Gainesboro District Supervisor Commissioner of Revenue Z V22. Final Location of CG-12 curb ramps shall be determined by VDOT inspector "F1TE 0VE0 DATF- Jane Anderson, eal Estate em: George Kriz and Charles Triplett, Gainesboro Planning Commissioners > O O1. WATER AND SEWER LINES ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THESE PLANS. THE LINES SHALL W ADDITIONALLY MEET ALL REQUIREMENTS OF THE FREDERICK COUNTY SANITATION AUTHORITY. U 2. THE CONTRACTOR SHALL COORDINATE WITH, AND ARRANGE FOR INSPECTION BY THE AUTHORITY. FIRE MARSHALLr S NOTE APPROVED BY ZONING ADMINISTRATOR SHEET INDEX P1411.1 ro, SHEET NO. 1 COVER SHEET 3. EXACT LOCATIONS OF WATER AND SEWER SERVICES ARE TO BE COORDINATED WITH THE AUTHORITY'S INSPECTOR. W R' 4. THE SANITATION AUTHORITY'S MAINTENANCE DEPARTMENT IS RESPONSIBLE FOR THE INSTALLATION OF WATER Fire lane markings and signage: Any "No Parking" signs and locations be installed 2 yellow painted curb will ZONING ADMINISTRATOR DAT2 SHEET NO. 2 SITE PLAN Z METERS THROUGH 2" IN SIZE. BEFORE A PERMANENT METER IS SET, THEY REQUIRE: 1) THE FRAME AND COVER TO by field inspection at the direction of the Fire Marshall's Office. �D BE PROPERLY ALIGNED WITH ITS METER BOX AND YOKE BAR; 2 THE FRAME AND COVER TO BE SET TO THE FINAL This Site Plan is valid for five (5) years from approval date . SHEET N0. 3 E & S PLAN & DETAILS GRADE OF THE LOT; 3) THE DISTANCE BETWEEN THE TOP OF THE COVER AND YOKE BAR BE BETWEEN 18 AND 21 INCHES; AND 4) ALL COMPONENTS OF THE METER BOX ASSEMBLY TO BE IN PROPER WORKING ORDER. IT IS THE TRIP GENERATION DATA COVER SHEET DEVELOPER'S/CONTRACTOR'S RESPONSIBILITY TO HAVE THE METER BOX ASSEMBLY INSTALLED CORRECTLY. H OF . CLASS USE DWELLING UNITS * TRIP RATE TRIP RATE USE VPD 5. FOR WATER AND SEWER SERVICES THAT CONNECT TO EXISTING LINES: A. THE LOCATION OF THE SERVICE LATERAL IS TO BE COORDINATED WITH THE AUTHORITY'S ENGINEERING Project Name: Project Number: ASSISTANT. AN APPLICATION FOR SERVICE MUST BE MADE AND FEES PAID BEFORE WORK WILL BEGIN. U MARK D. SMITH M A B. THE AUTHORITY SHALL FURNISH AND INSTALL ALL 5/8", 3/4" AND 1" WATER SERVICES. C. FOR ALL 1 1 /2" AND 2" WATER SERVICES, THE AUTHORITY SHALL MAKE THE TAP AND BRING THE PIPING TO NOT A PL IC,4BLE "b No.022837 '� O w HUNTING RIDGE UNMANNED COMMUNICATION FACILITY 3296 �, ®Try p hp'� 0�� I"I�-ll°�P�III'•���l�C•�ii° THE PROPERTY LINE. THE CONTRACTOR IS TO FURNISH & INSTALL THE METER VAULT ASSEMBLY. THE AUTHORITY (UNM NNED TOWER NC PROP05ED D,41 Y TRAFFIC) !, k WILL INSTALL THE METER. `SfONAL Magisterial District: Date of Plan: (Month, Day, Year) D. THE AUTHORITY WILL INSTALL ALL SEWER LATERALS. GAINESBORO DISTRICT 03/26/02 6. WHEN AN EXISTING WATER MAIN IS TAPPED FOR THE INSTALLATION OF A NEW LINE: A. THE AUTHORITY SHALL FURNISH ALL LABOR AND MATERIALS TO MAKE THE TAP. UTILITY CONTACTS Owner: Address, Including Zip Code &Telephone No. 329 HUNTING RIDGE ROAD B. THE DEVELOPER/CONTRACTOR MUST: 1) MAKE APPLICATION FOR THE TAP, 2) PAY DEPOSIT (BEFORE WORK BEGINS); 3) MARK THE LOCATION OF THE TAP; AND 4) MAKE FINAL PAYMENT WHEN THE WORK IS COMPLETED. PROFESSIONAL SEAL &SIGNATURE TALBERT AND JOYCE DEHAVEN WINCHESTER, VIRGINIA 22603 Frederick County Sanitation Authority Phone: Verizon DATE: March-2002 7. THE CONTRACTOR SHALL TIE-IN A NEW LINE TO AN EXISTING MANHOLE BY CORE DRILLING THE MANHOLE. THESE PLANS ARE IN CONFORMANCE WITH P.O. Box 1877 P.O. Box 17398 FREDERICK COUNTY STANDARDS AND Developer: Address, Including Zip Code & Telephone No. 8. ANY WATER SERVICE LINE MUST HAVE A DOUBLE CHECK VALVE OR RPZ BACKFLOW PREVENTION ASSEMBLY, AS Winchester, VA. 22604 Baltimore, MD 21297 ORDINANCES. ANY DEVIATION OR CHANGE 6501 SANDY KNOLL COURT DESIGNED BY: DLF REQUIRED, INSTALLED. THE ASSEMBLY SHALL MEET ASSE STANDARD No. 1015 OR 1013. A REMOTE READOUT IS (540) 868-1061 (301) 954-6282 IN THESE PLANS SHALL BE APPROVED BY SHARED TOWERS, L.L.C. McLEAN, VIRGINIA 22101 REQUIRED. Power: Allegheny Power Gas: Shenandoah Gas Co. E ZONING ADMINISTRATOR PRIOR TO (703) 893-1571 CHECKED BY: EAW 9. ALL FIRE LINES SHALL HAVE A DETECTOR DOUBLE CHECK VALVE BACKFLOW PREVENTION ASSEMBLY OR A RPZ P.O. Box 1458 P.O. Box 2400 Hagerstown, MD 21741 Winchester, VA 22604 Engineer Certifying Plan: Address, Including Zip Code & Telephone No. JOB NO. 3296 BACKFLOW ASSEMBLY AS REQUIRED. THE ASSEMBLY SHALL MEET ASSE STANDARD No. 1048 OR 1047. A REMOTE 1-800-654-3317 (540) 869-1111 151 Windy Hill Lane READOUT IS REQUIRED. GreenwayEngineering Winchester, VA 22602 MISS UTILITY 1-800-257-7777 (540) 662-4185 SHEET 1 OF 3 AREA 1"IAiP SCALE: 1 " = 400' c O c0 C U a� fY c rn N ch in a� 0 GENERAL SITE NOTES: I. ENTIRE FENCED AREA IS TO BE COVERED WITH FILTER FABRIC a ro" GRAVEL. 2. FACILITY SHALL BE CONSTRUCTED WITH MATERIAL OF A GALVANIZED FINISH OR PAINTED A NON -CONTRASTING BLUE OR GRAY, UNLESS OTHERW15E MANDATED BY FAA OR FCC REGULATIONS. 3, A Co' STOCKADE FENCE WILL BE REQUIRED ON ANY SIDE OF THE TOWER FACILITY'S TOWER PAD SITE THAT IS VISIBLE FROM ADJACENT ROADWAYS AND RESIDENCES. 4. THE INGRESS/EGRESS EASEMENT FOR THE ACCESS ROAD SHALL BE RECORDED UPON COMPLETION OF ACCESS ROAD CONSTRUCTION. LEASE AGREEMENT WILL BE STATED AS FOLLOWS: "THE EX6LU5IVE RIGHT TO USE AND OCCUPY REAL PROPERTY, APPROXIMATELY /0,000 SQUARE FEET OF LAND, AS APPROXIMATELY DESCRIBED AND SHOWN ON EXHIBIT A, TOGETHER WITH NON-EXCLUSIVE EASEMENT5 (a) TO PURL IC RIGHT -OF -WA r FOR REA50NABLE ACCESS, (b) TO THE APPROPRIATE SOURCES OF ELECTRIC AND TELEPHONE FACILITIES AS OETERMINEO BY LE55EE, (6) FOR PLACEMENT OF ANY SUPPORTING GUYED WIRES A5 REA50NAOLY DETERMINED BY LE55EE PER GOOD ENGINEER/NO PRACTICES AND (d) TO MEET FALL -ZONE OR SET BACK REOUIREMENTS (COLLECTIVELY, THE "5/TE'%." TOWEiz AFEA GRAVEL PAVE1" LENT SECTION NOT TO SCALE C;RAVEL PETAL 6" SUBBASE VDOT STD. GR-21A -III—III—III-1 I I —III —III —III --III. COMPACTED SUBGRADE i_I i 1=1 i 1—I 11—I 11—I I I_I I I-1 IL I 11=1 (COMPACTED TO S5% DENSITY AT OPTIMUM M015TURE CONTENT VDOT VTM-I METHOD) PAVEMENT DESIGN BASED ON A SUBGRADE CBR DESIGN VALUE OF 10. SOIL TEST OF THE SUBGRADE MUST SUBMITTED FOR ACTUAL DETERIINATION OF REQUIRED PAVEMENT SECTION THICKNESS PRIOR TO CONSTRUCTION. PvMT3ECT WIRE ME514 REINFORCING VD.O.T, ROAD AND BRIDGE STANDARDS SECTION 301,04 411 �— CLASS A-3 CONCRETE \�6" BASE: 21-A COMPACTED SUBGRADE (COMPACTED TO 9596 DENSITY AT OPTIMUM MOISTURE CONTENT, VDOT 5TM-1 MET✓ -#OD) CONCfRETE FAD (NOT TO SCALE) I"X4"X4'-8" SLATS, 2-FNISH NAIL AT TOP AND BOTTOM 2"X4"X4' BEAMS, TOE NAIL TO POST 4"X4"X8' POSTS 1-25" ll,AI, NOTES: _ I. PRESERVATIVE STAIN ON ALL WOOD. COLOR TO MATCH THAT OF BLDG. a 2. FINISHED SIDE OF FENCE SHALL FACE IN ADJOINING PROPERTY, IF APPLICABLE. - COMPACTED GRAVEL &' WOOD STOCKADE FENCE DETAIL NOT TO SCALE SET TREE LEVEL AND PLUMB --STRAIGHTEN AFTER SETTLEMENT IF REQUIRED. SET TREE WITH TOP VS OF ROOT BALL ABOVE FNISHED GRADE ENCASE WIRE AROUND TRIAJGK IN BLACK RUBBER HOSE. SECURE AT HEIGHT ABOVE FINISHED GRADE EQUAL TO 1/3-1/2 OF TREE REMOVE TOP 1/3 OF BURLAP AND CUT ROPE AND/OR REMOVE WIRE BASKET FROM BALL 3UY WIRE 92 GAUCsE B" DOUBLE SHREDDED HARDUK,OD 3' SOIL SAUCER 3 STAKES BACKFILL LIGHTLY COMPACTED SETTLING MOUND TYPICAL PLANTING DETAIL-- EVERGREEN TREES (NOT TO SCALE) o \ . COl"IMERCIAL/INIDUSTRIAL \ \ - Zcm: - E;4,itm� *4.41, o `7 padjAbus .40ox TOWER � ACCESS LANE ` �S 6 o \ 1 EX. 7 Ei=,L!�[ _ .._ ,ti / f✓ '` \ I I Q - / CIO /In N/F= / DEHAVEN USE: RESIDENTIAL., �\ ZONE RA �rA � A f \ \ ✓ TOWER ` ACCESS �- LANE' ( \ s e b"EVEIIR&REEN PLANTING 10" O.G. \ 10, . x 5- 6 E , PLANTIN6 10 O.G. / BARBED WIFE FENCE 100, \ W/12' DOUBLE GATE, \ 20 / , \ 0 ^r ` \ l Ns TYPICAL \ _ Q 10' x 20' JONESs t 21I' TOWER -SITE U6E : AGRICULTURE HEIGHT■ • rr ZONE : RA _f '_1 LEASE 835' 3 0 — 4 ` �U KJ \ j t AREA vL J - J 4 \ Z W W Z Z Wc\1 0 CO "n oI °A I rn Z �> x -t �eq L1J ) Q o tJJ D cc V)V) Iv 0 F_: Q) w to CD O Cp N d- z E E 0 0 6 v Q a a U c: c o0 C CL CL W N N Q Lr) OF 'v vv ARK D. S TH �' No.022837 W (51 sIONAL. E--+ uj O Z cc L L E,� V ) �E- ww Z �D O 00 n Z O v1 Q F� H TD i Z �w rQ, w 50 0 100 DATE: MAY-2002 SGALE: 1 " = 50' SCALE: 1" = 50' DESIGNED BY: DLF FILE NO. 3296 SHEET 2 OF 3 02 CONSTRUCTION OF A SILT FENCE (WITH WIRE S UPPOR T) 1. SET POSTS AND EXCAVATE A 4"X4" 2. STAPLE WIRE FENCING TO THE POSTS. TRENCH UPSLOPE ALONG THE LINE OF POSTS. i f I FLOW 4" 3. ATTACH THE FILTER FABRIC TO THE WIRE FENCE AND EXTEND IT INTO THE TRENCH. 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. ///ir I J G FLOW AJI)ll 100 EXTENSION OF FABRIC AND WIRE INTO THE TRENCH. SOURCE: Adapted from Installation of Straw and Fabric Filter Barriers for Sediment Control, PLATE. 3.05-1 Shmood k Nrant STONE CONSTRUCTION ENTRANCE GROUND 70' MIN. A FILTER CLOTH -- 6" MIN. I A I SIDE ELEVATION 12' MIN. « VDOT #1 COURSE AGGREGATE * MUST EXTEND FULL WIDTH OF INGRESS AND EGRESS OPERATION RELNr VM,LU VVM,RG IG UKAIN N'Al:t 70' MIN. B ~� POSITIVE DRAINAGE B TO SEDIMENT TRAPPING DEVICE PLAN VIEW SECTION A —A SECTION B—B SOURCE: ADAPTED from 1983 M#gnd Standards for Soil erosion and Sediment Control, and Va. DSWC Plate 3.02-1 RE5PON51BLE LAND DISTURBER NAME: GERTIFIGATION #: DATE: THE RE5PON51BLE LAND D15TURBER IS THE PARTY RE5PON51BLE FOR GRRRIN6 OUT THE LAND DISTURBING ACTIVITY A5 5ET FORTH IN THE PLANS. Xi I 1 N r \ 410 } t , l �C-)) �,A � P . 2•. � F 1 � ` "tip. � • / p / f �Y ; f/ /� ,.✓r gyp•, ,! s 5F ZONE RA r, i xl % i 100 0 100 i 200 SGALE 1" = 100' EROSION AND SEDIMENT GONTROL NARRATIVE HUNTI NCB RI D6E UNMANNED GOMMUNI GATT ON FAG I L I TY Description: This project proposes the construction of a new communication tower facility. This project includes the construction of approximately 5 concrete pads for a IG5' lattice tower and it's mechanical equipment. Existing site conditions: The area to be disturbed under this plan is currently on open area within a partially wooded lot. Adjacent areas: This property bordered on all sides by residential land use in RA zoning. Critical areas: There are no unusual or critical areas at this site. Erosion and sediment control measures: Gontrol of erosion and Sedimentation for this site shall be achieved by installing the following. I. Gon5truction entrance. 2. Gonstruct Silt fence. 3. Soil stabilization through permanent seeding of any unpaved disturbed areas. Permanent stabilization: Once construction Is complete, all disturbed areas not built upon or paved shall be covered with a minimum of four (4) inches of topsoil. Fertilizer, Seeding and a blanket of straw shall be applied to the topsoil. Stormwater management: There is no proposed stormwater management for this project. Maintenance Program: The erosion and sediment control measures installed on the site shall be maintained by performing the following. I. The site superintendent shall inspect all erosion and sediment control devices after each rainfall and at least daily during prolonged rainfall. Damaged or deficient controls Shall be repaired or improved immediately. 2 The 51te superintendent shall inspect dolly the areas construction activity to insure erosion control effectiveness. Additional measures shall be installed immediately where deficiencies are found. 3. Permanent erosion control measures include the installation of rip rap at storm sewer outfolls and the establishment of gra55 on exposed Surfaces disturbed in the construction process. Erosion and sediment control program I. Hold pre constructlon meeting on site. 2. Install construction entrance. 3. Installation of silt fence. 4. Grade the site, install concrete pads. 5. After approval by the inspector, remove the temporary control devices and stabilize the areas disturbed during removal. Note: Frederick Gounty retains the right to add and/or modify these erosion and sediment control measures during the construction process, within reason, to ensure adequate protection to the public and the environment. Seeding schedule (soil stabilization): I. Spread topsoil at a minimum depth of four (4) inches. 2. Incorporate pulverized agricultural limestone into the topsoil at a rate of c12 Ib5. per 1,000 square feet (2 tons per acre). 3. Fertilize with 10-10-10 fertilizer at a rate of 23 Ibs per 1,000 square feet (1,000 Ib5 per acre). 4. Seed all areas with a seed mix consisting of 679 Kentucky 31 Tall Fescue and 53% Red Top Glover. 5. Mulch all seeded areas with straw mulch applied at a rate of 5,500 Ib5 per acre, anchored with cutback or emulsified asphalt applied of a rate of 200 gallons per acre. V Z W W Z Z WC\1 O � :n � Q i C� Zx �> i V)C\J UJ a W� a:n can) o� ^ tom.. tom, N 0 N 7+ W� N N \ tL� 0 w 0 Z E E O U U H C W C) 0 a Cn C C v v a`) a a a cu w Ln cn W C N A N N v U7 �w FPO i"N . L -r V - \-/ MARK D. SMITH 9 No.002009 r4 F--I H W Q Q � W F-, 0 0 �> O E-p O Q E- Z O�D O4. O0 E-+ Z O W U Q U1 � � � LzI Z O O W DATE: MAY-2002 SCALE: - AS SHOWN DESIGNED BY: - DLF FILE NO. - 3296 SHEET - 3 OF- 3 GENERAL NOTES VD 0 T GENERAL NOTES LEGEND VICINITY MAP SCALE 1 2000' V1. All work on this project shall conform to the latest editions of the Virginia Department of Transportation (VDOT) Road and Bridge Specifications and Standards, the Virginia Erosion and EXISTING INTERMEDIATE CONTaU-TZ-------__, 33 1. Methods and materials used in the construction of the improvements herein shall conform to the current Sediment Control Regulations and any other state, federal or local regulations applicable. In the event of conflict between any of these standards, specifications or the most stringent shall be EXISTING INDEX CONTOUR V UJ County construction standards and specifications and/or current VDOT standards and specifications. plans, govern. UJ PROPOSED CONTOUR 2. Measures to control erosion and siltation, including detention ponds serving as silt basins during construction, V2. All construction shall comply with the latest U.S. Department of Labor, Occupational Safety and EXISTING EDGE OF PAVEMENT must be provided prior to issuance of the site development permit. The approval of these plans in no way Health Administration and VOSH Rules and Regulations. PROP E/P relieves the developer or his agent of the responsibilities contained in the Virginia Siltation and Erosion PROPOSED EDGE OF PAVEMENT Control Handbook. V3. When working on VDOT right-of-way, all traffic control, whether permanent or temporary, shall 1 1 X k", 8t Cy, EXISTING CURB AND GUTTER 3. A permit must be obtained from the Office of the Resident Engineer, Virginia Department of Transportation be in accordance with the current edition of VDOT's work area protection manual. Furthermore, all flaggers be in the latest VDOT Road PROP C&G ... P� C\1 (VDOT) and Frederick County to construction in existing State right-of-way. traffic control must certified accordance with edition of the and PROPOSED CURB AND GUTTER prior 4. Approval of this plan does not guarantee issuance of an entrance permit by VDOT when such permit is Bridge Specifications, Section 104.04-C. CG-6 CG-6R FROM CG-6 TO CG-6R 41 co 01 V4. The developer shall be responsible for relocating, at his expense, any and all utilities, including TRANSITION \< required under State law. 5. The exact location of all guard rails will be determined by VDOT personnel. "A joint inspection will be held traffic signal poles, junction boxes, controllers, etc. owned by VDOT or private utility company. It is the sole responsibility of the developer to locate and identify utility facilities or items, which in ay be in conflict with the proposed construction activity. VDOT approval of these plans does not EXISTING TELEPHONE LINE PROPOSED TELEPHONE LINE A CQ CC) (0 LO 0) with the Developer, County Representatives, and Representatives of the Virginia Department of Transportation 0 1 (VDOT) to determine if and where guard rail and of paved ditches will be needed. The developer will be relieve the developer of this responsibility. Ex. 15" RCIP C\1 Z responsible for providing guardrail and paved ditches as determined by this joint inspection." Refer to V5. Design features relating to field construction, regulations, and control or safety of traffic may EXISTING STORM SEWER PROP. 15n RCP iN CV >-. cu Virginia Department of Transportation (VDOT) Guard Rail and Paved Ditch Specifications. be subject to change as deemed necessary by VDOT. Any additional expense incurred as a result of PROPOSED STORM SEWER MEN= P - I 1V 0 C) 6. An approved set of plans and all applicable permits must be available at the construction site. Also, a any field revision will be the responsibility of the developer. _V M, -4 ti representative of the developer must be available at all times. V6. Prior to initiation of work, the contractor shall be responsible for acquiring all necessary VDOT EXISTING SANITARY SEWER ------ V "N 7. Warning signs, markers, barricades or flagmen should be in accordance with the Manual on Uniform Traffic land use permits for any work on VDOT right-of-way. PROPOSED SANITARY SEWER N& Z' Lo E- 4. Control Devices (MUTCD). V7. If required by the local VDOT Residency Office, a pre -construction conference must be arranged EXISTING ELECTRIC SERVICE 22- 8. All unsuitable material shall be removed from the construction limits of the roadway before placing and held by the engineer and/or developer with the attendance of the contractor, various County embankment. agencies, utility companies and VDOT prior to initiation of work. PROPOSED ELECTRIC SERVICE Q) 0 PROJECT INFORMATION 9. All pavement sections on the approved plans are based on a minimum CBR value of 6. CBR values less V8. The contractor shall notify the local VDOT Residency Office when work is to begin or cease for EXISTING GAS LINE than 6 will require revised pavement section prepared by Greenway Engineering and approved by the owner. any undetermined length of time. VDOT will also require 48 hours notice for any inspection. PROPOSED GAS L LINE PARCEL IDENTIFICATION: PIN # 30A-98C 10. All roadside ditches at grades of more than 5% shall be paved with cement concrete to the limits indicated V9. The contractor will be responsible for maintaining adequate access to the project from the oil the plans and as required at the field inspection. adjacent public roadway through construction and maintenance of a construction entrance in PROPERTY LINE CURRENT ZONING: RA SETBACKS: REQUIRED: PROPOSED: accordance with the Virginia Erosion and Sediment Control Handbook, Section 3.02. Furthermore, FRONT: 220' FRONT: 835' 11. All springs shall be capped and piped to the nearest storm sewer manholes or curb inlet. The pipe shall access to other properties affected by this project shall be maintained through construction. The FLOW LINE CURRENT USE: VACANT SIDE: 210' SIDE: 627' be minimum 6" diameter and conform to VDOT standard SB-1. Developer shall have, within the limits of the project, an employee certified by the Department of FENCELINE X PROPOSED USE: UNMANNED COMMUNICATION FACILITY REAR: 210' REAR: 211' Conservation and Recreation in Erosion and Sediment Control who shall inspect erosion and siltation C\2 CQ 12. Construction debris shall be containerized in accordance with the Virginia Litter Control Act; no less than control devices and measures for proper installation and deficiencies immediately after each rainfall, EXISTING POWER POLE _0 CQ one litter receptacle shall be provided at the construction site. at lest daily during prolonged rainfall, and weekly when no rainfall event occurs. SITE AREA: 35.0 AC OUTDOOR LIGHTING: NONE SPECIFIED C\2 CQ EXISTING TELEPHONE POLE 0 DISTURBED AREA: 20,000 SF OUTDOOR STORAGE: NONE SPECIFIED 13. The contractor shall provide adequate means of cleaning mud from trucks and/or other equipment prior to VIO. Contractor shall ensure adequate drainage is achieved and maintained on the site during and LEASE AREA: 10,000 SF 0 entering public streets, and it is the contractors responsibility to clean streets, allay dust, and to take at the end of construction. EXISTING WATERLINE W1 TEE cn Cn whatever measures are necessary to insure that the streets are maintained in a clean, mud and dust free V11. All water and sewer lines within existing or proposed VDOT right-of-way are to have minimum PROPOSED WATERLINE W/ TEE ENVIRONMENTAL FEATURES: EXISTING IRRIGATION POND WILL NOT BE Z 0 0 Cu condition at all times. 36" cover and, when possible, to be installed under roadway drainage facilities. DISTURBED WITH DEVELOPMENT OF THIS SITE. 0 H El H 14. Notification shall be given to the appropriate utility company prior to construction of water and/or sanitary PROPOSED FIRE HYDRANT � C:> U sewer lines. Information should also be obtained from the appropriate authority concerning permits, cut V12. Any unusual subsurface conditions encountered during the course of construction shall be > sheets, and connections to existing lines. immediately brought to the attention of the engineer and VDOT. Work shall cease in that vicinity EXISTING WATER VALVE AIR TRAFFIC CONTROL LIGHTING WILL BE until an adequate design can be determined by the engineer and approved by VDOT. PROVIDED AS REQUIRED BY REGIONAL 15. All sanitary sewers and water mains and appurtenances shall be constructed in accordance with the current V13. All fill borrow be inspected by VDOT PROPOSED WATER METER AIRPORT AUTHORITY. standards and specifications of Frederick County and/or the Frederick County Public Service Authority. areas, material and undercut areas shall and approved a to fill. Where CBR testing is VDOT EXISTING REDUCER representative prior placement and required, a representative 10 16. The location of existing utilities shown in these plans are taken from existing records. It shall be the contractors responsibility to verify the exact horizontal and vertical location of all existing utilities as needed shall be present to insure the sample obtained is representative of the location. When soil samples are submitted to private laboratories for testing, the samples shall be clearly identified and labeled PROPOSED REDUCER 77 4- prior to construction. The contractor shall inform the engineer of any conflicts arising from his existing as belonging to a project which will be accepted by VDOT and that testing shall be conducted STOP SIGN .0 COUNTY of FREDERICK A. according to all applicable VDOT standards. utility verification and the proposed construction. VEHICLES PER DAY COUNT 100 Department of Planning and Development 17. The developer will be responsible for any damage to the existing streets and utilities which occurs as a V14. All roadway fill, base, subsurface material and backfill of utility/storm sewer trenches shall be PROPOSED STREET NAME SIGN 540/665-S651 FAX: 5401665-6395 Q) Q) result of his construction project within or contiguous to the existing right-of-way. compacted in 6" lifts to 95% of theoretical maximum density as determined by AASHTO T-99 Method A, within plus or minus 2% of optimum moisture for the full width of any dedicated street PROPOSED SANITARY LATERAL CLEANOUT March 14, 2002 18. When grading is proposed within easements of utilities, letters of permission from all involved companies right-of-way. At the direction of VDOT Inspector, density tests performed by a qualified independent agency shall be conducted as required in the VDOT Road and Bridge Specifications. A SANITARY MANHOLE IDENTIFIER W C-2 CQ must be provided to Frederick County Public Service Authority prior to issuance of grading and/or site cr) development permits. copy of all tests shall be submitted to VDOT prior to final VDOT approval. Mr. Karnal Doshi Shared rowers, LLC 19. The developer will be responsible for the relocation of any utilities which is required as a result of his V15. VDOT Standard CD and UD under -drains shall be installed where indicated on these plans and STORM DRAIN STRUCTURE IDENTIFIER 6 6501 Sandy Knoll Court project. The relocation should be done prior to construction. further where determined necessary by VDOT Inspector. McLean, VA 22101 20. These plans identify the location of all known gravesites. Gravesites shown on this plan will be protected V16. The installation of any entrances and mailboxes within any dedicated street right-of-way shall EASEMENT LINE PE: CUP #05-02 for the RuAting ludge Telecommunications Facility; P.LN. 30-A-98C in accordance with state law. In the event gravesites are discovered during construction, the owner and meet VDOT minimum design standards and is the responsibility of the developer. CENTERLINE DeaT Vr. Doshi: engineer must be notified immediately. V17. Prior to acceptance by VDOT of any streets, any required street signage and/or pavement n, EXISTING SPOT ELEVATION This letter is to confirm action taken by the Frederick County Board of Supervisors at their meeting on Miarch. 13, 2002. Your application, Conditional Use Permit 005-02 for a 195-foot lattice -type 21. The contractor is to verify field conditions prior to and during construction and notify Greenway Engineering markings must be installed by the developer or at VDOT's discretion, by VDOT on an account telecommunications tower with a waiver ofthe setbacks to the internal parcel boundary lines was approved at (540) 662-4185 immediately of any discrepancies between actual field conditions and the approved plan. receivable basis. Stop signs shall be thirty (30) inches tall with high intensity sheeting. The + PROPOSED SPOT ELEVATION 715-1 with tb,: following conditions: bottom of the sign shall be six (6) feet above the edge of pavement and the post shall be installed 1. All Zoning Ordinance requirements andrevim agencycomments shallbe addressed and complied 22. Controlled fills shall be compacted to 95% of maximum density as determined by method "A" per standard a minimum of four (4) feet from the edge of pavement. Sign posts shall be of a type found on EXISTING TREE DRIP LINE with at all 'Limes. proctor AASHTO-T99, ASTM-D698, or VTM-1 as applicable. Density shall be certified by a registered VDOT's approved list. A copy of this list may be obtained from the District Material Section. professional engineer and results submitted to Frederick County prior to pavement construction. If a Contact the local VD1OT Residency Office with any questions regarding sign material and placement. 2. The tower shall be available for co -locating personal wireless services providers. geotechnical report has been prepared, it should supersede the requirements in this note. V18. The developer must provide to the local VDOT office a list of all material sources prior to 3. A minor site plan shall be approved by the County. 23. Contractors shall notify operators who maintain underground utility lines in the area of proposed excavating construction. Copies of all invoices for materials within any dedicated street right-of-way must be 4. The tower she be removed by the applicant or property owner within twelve (12) months of or blasting at least two (2) working days, but not more than ten (10) working days, prior to commencement provided to the local VDOT Residency Office prior to acceptance of the work. Unit and total prices be abandonment of operation. of excavation or demolition. Names and telephone numbers of the and operators underground utility lines may obscured. 5. In the event a telecommunications tower is not erected within twelve (12) months of the approval in Frederick County appear below. These numbers shall also be used to serve in an emergency condition. V19. Aggregate bases and sub -bases shall be placed on the sub -grade by means of a mechanical of this Conditional Use Permit; then the CUP will be deeded invalid. spreader. Density will be determined using the density control strip as specified in VDOT's Road and 6. Issuance ofCUP #05-02 shall make the Conditional Use Permit (CUP419-0 1) previously issuedffbr E- Bridge Specifications -Section 304 and VTM-10. A certified compaction technician shall perform these an adjoining property (same property owner) invalid. tests. A certified copy of the test results shall be provided to the Residency Office. In additions to checking stone depths, a VDOT representative shall be notified and given the opportunity to be If you have any questions regarding this action orthe site plan approval process, please feel free to call this office. W C present during the construction and testing of the density control strip. E- V20. Asphalt concrete pavement shall be placed in accordance with the latest edition of VDOT's Road and Bridge Specifications -Section 315. Density be determined the density Since Y, > will using control strip as in Section 315 VTM-76. A technician these tests. E- specified and certified compaction shall perform awrence ELA]CP, CZA r" A certified copy of the test results shall be provided to the Residency Office. A VDOT representative Deputy Director W Q - >- shall be notified and given the opportunity to be present during the construction and testing of the u fZ� E- control strip. V21. Approval of these plans shall expire three (3) years from the date of the approval letter. V22. Final Location of CG-12 curb ramps shall be determined by VDOT inspector NAL '! E PLJ�N A F'ROV�cD W --OAT SPLUch cc: Mark Smith, Greenway Engineering Sidney Reyes, Gainesbora District Supervisor Commissioner of Revenue Jane Anderson, Real Estate cm: George Kriz and Charles Triplett, Gainesboro Planning Commissioners 0 �D Z > 0 FCSA CONSTRUCTION NOTES WATER WITH THESE PLANS. THE LINES SHALL l. AND SEWER LINES ARE TO BE CONSTRUCTED IN ACCORDANCE ADDITIONALLY MEET ALL REQUIREMENTS OF THE FREDERICK COUNTY SANITATION AUTHORITY. U Z 2. THE CONTRACTOR SHALL COORDINATE WITH, AND ARRANGE FOR INSPECTION BY THE AUTHORITY. FIRE MARSHALLS NOTE APPROVED BY ZONING ADMINISTRATOR ATOR SHEET INDEX 3. EXACT LOCATIONS OF WATER AND SEWER SERVICES ARE TO BE COORDINATED WITH THE AUTHORITY'S INSPECTOR. Fire lane markings and signage: i SHEET NO.1 COVER SHEET �4 4. THE SANITATION AUTHORITY'S MAINTENANCE DEPARTMENT IS RESPONSIBLE FOR THE INSTALLATION OF WATER Any "No Parking" signs and yellow painted curb locations will be installed V 051311CA ZONING ADMINISTRATOR DATE SHEET NO. 2 SITE PLAN 4.4 Z METERS THROUGH 2" IN SIZE. BEFORE A PERMANENT METER IS SET, THEY REQUIRE: 1) THE FRAME AND COVER TO by field inspection at the direction of the Fire Marshall's Office. � BE PROPERLY ALIGNED WITH ITS METER BOX AND YOKE BAR; 2) THE FRAME AND COVER TO BE SET TO THE FINAL This Site Plan is valid for five (5) years from approval date. SHEET NO. 3 E & S PLAN & DETAILS GRADE OF THE LOT; 3) THE DISTANCE BETWEEN THE TOP OF THE COVER AND YOKE BAR BE BETWEEN 18 AND 21 INCHES; AND 4) ALL COMPONENTS OF THE METER BOX ASSEMBLY TO BE IN PROPER WORKING ORDER. IT IS THE TRIP GENERATION DATA CO VER SHEET DEVELOPER'S/CONTRACTOR'S RESPONSIBILITY TO HAVE THE METER BOX ASSEMBLY INSTALLED CORRECTLY. H OF CLASS USE DWELLING UNITS TRIP RATE TRIP RATE USE VPD 5. FOR WATER AND SEWER SERVICES THAT CONNECT TO EXISTING LINES: A. THE LOCATION OF THE SERVICE LATERAL IS TO BE COORDINATED WITH THE AUTHORITY'S ENGINEERING Project Name: Project Number: ASSISTANT. AN APPLICATION FOR SERVICE MUST BE MADE AND FEES PAID BEFORE WORK WILL BEGIN. U MARK D. SMITH B. THE AUTHORITY SHALL FURNISH AND INSTALL ALL 5/8", 3/4" AND 1" WATER SERVICES. C. FOR ALL 1 1/2" AND 2" WATER SERVICES, THE AUTHORITY SHALL MAKE THE TAP AND BRING THE PIPING TO NOT A=f=L1r_A5LE ro, No. 022837 A 0 HUNTING RIDGE UNMANNED COMMUNICATION FACILITY 3296 THE PROPERTY LINE. THE CONTRACTOR IS TO FURNISH & INSTALL THE METER VAULT ASSEMBLY. THE AUTHORITY WILL INSTALL THE METER. (UNMANNED TOWER NC 1=ROPO5EC> DAILY TRAFFIC:) "'ONAL Magisterial District: Date of Plan: (Month, Day, Year) D. THE AUTHORITY WILL INSTALL ALL SEWER LATERALS. GAINESBORO DISTRICT 03/26/02 6. WHEN AN EXISTING WATER MAIN IS TAPPED FOR THE INSTALLATION OF A NEW LINE: A. THE AUTHORITY SHALL FURNISH ALL LABOR AND MATERIALS TO MAKE THE TAP. UTILITY CONTACTS Owner: Address, Including Zip Code & Telephone No. B. THE DEVELOPER/CONTRACTOR MUST: 1) MAKE APPLICATION FOR THE TAP, 2) PAY DEPOSIT (BEFORE WORK BEGINS); 3) MARK THE LOCATION OF THE TAP; AND 4) MAKE FINAL PAYMENT WHEN THE WORK IS COMPLETED. PROFESSIONAL SEAL & SIGNATURE TALBERT AND JOYCE DEHAVEN 329 HUNTING RIDGE ROAD WINCHESTER, VIRGINIA 22603 Frederick County Sanitation Authority Phone: Verizon DATE: March-2002 7. THE CONTRACTOR SHALL TIE-IN A NEW LINE TO AN EXISTING MANHOLE BY CORE DRILLING THE MANHOLE. THESE PLANS ARE IN CONFORMANCE WITH P.O. Box 1877 P.O. Box 17398 FREDERICK COUNTY STANDARDS AND Developer: Address, Including Zip Code & Telephone No. 8, ANY WATER SERVICE LINE MUST HAVE A DOUBLE CHECK VALVE OR RPZ BACKFLOW PREVENTION ASSEMBLY, AS Winchester, VA. 22604 Baltimore, MD 21297 ORDINANCES. ANY DEVIATION OR CHANGE 6501 SANDY KNOLL COURT DESIGNED BY: DLF REQUIRED, INSTALLED. THE ASSEMBLY SHALL MEET ASSE STANDARD No. 1015 OR 1013. A REMOTE READOUT IS (540) 868-1061 (301) 954-6282 IN THESE PLANS SHALL BE APPROVED BY SHARED TOWERS, L.L.C. McLEAN, VIRGINIA 22101 CHECKED BY: EAW REQUIRED. Power: Allegheny Power Gas: Shenandoah Gas Co. THE ZONING ADMINISTRATOR PRIOR TO (703) 893-1571 P.O. Box 1458 P.O. Box 2400 Engineer Certifying Plan: Address, Including Zip Code & Telephone No. 9. ALL FIRE LINES SHALL HAVE A DETECTOR DOUBLE CHECK VALVE BACKFLOW PREVENTION ASSEMBLY OR A RPZ Hagerstown, MD 21741 Winchester, VA 22604 JOB NO. 3296 BACKFLOW ASSEMBLY AS REQUIRED. THE ASSEMBLY SHALL MEET ASSE STANDARD No. 1048 OR 1047. A REMOTE 1-800-654-3317 (540) 869-1111 Greenway Engineering 151 Windy Hill Lane Winchester, VA 22602 READOUT IS REQUIRED. MISS UTILITY 1-800-257-7777 1 (540) 662-4185 SHEET 1 OF 3 ,4RE,4 i IAF SCALE: 1 "= 400' GENERAL SITE NOTES: 1, ENTIRE FENCED AREA IS TO BE COVERED WITH FILTER FABRIC 'a ro" GRAVEL, 2, FACILITY SHALL BE CONSTRUCTED WITH MATERIAL OF A GALVANIZED FINISH OR PAINTED A NON -CONTRASTING BLUE OR GRAY, UNLESS OTHERWISE MANDATED BY FAA OR FCC REGULATIONS, 3, A 6' STOCKADE FENCE WILL BE REQUIRED ON ANY SIDE OF THE TOWER FACILITY'S TOWER PAD 51TE THAT IS VISIBLE FROM ADJACENT ROADWAYS AND RESIDENCES, 4, THE INGRESS/EGRESS EASEMENT FOR THE ACCESS ROAD SHALL BE RECORDED UPON COMPLETION OF ACCESS ROAD CON5TRUCTION. LEASE AGREEMENT WILL BE STATED AS FOLLOWS: "THE EXCLU5/VE Rl614T TO USE AND OCCUPY REAL PROPERTY, AFFROXIMATELY /0,000 SQUARE FEET OF LAND, AS AFFROXIMATELY DESCRIBED AND SHOWN ON EXHIBI T A, TOGETHER WITH NON-EXGLU5/VE EASEMENTS (a) TO PURL IC R16HT-OF-WA y FOR REA30NABLE ACCESS, V TO THE AFFROFRIATE SOURCES OF ELECTRIC AND TELEPHONE FACILITIES AS DETERMINED BY LE55EE, (6) FOR PLACEMENT OF ANY SUPPORTING GUYED WIRES A5 REA50NAOLY DETERMINED BY LE55EE PER GOOD EN6/NEERIN6 FRA6TICE5 AND (d) TO MEET FALL -ZONE OR SET BACK REQUIREMENTS (COLLECTIVELY, THE "SITE')." TOWER AREA GRAVEL FAVEiMENT SECTION NOT TO SCALE II GRAVEL DETAIL (o" 5U55A5E VDOT 5TD. GR-21A iIIII�IIIII�IIIIFIIII�IIIII�IIIIFIIII�IIIIIIIII-COMPACTED 6UBGRADE (COMPACTED TO 95% DENSITY AT OPTIMUM MOISTURE CONTENT VDOT VTM-1 METHOD) PAVEMENT DESIGN BASED ON A SUBGRADE CBR DESIGN VALUE OF 10, SOIL TEST OF THE SUBGRADE MUST SUBMITTED FOR ACTUAL DETERMINATION OF REQUIRED PAVEMENT SECTION TPICKNE55 PRIOR TO CONSTRUCTION. PV IITSECT WIRE MESH REINFORCING VD.O.T. ROAD AND BRIDGE STANDARDS SECTION 30104 (o " i 4� ,. 77 CLA55 A-3 CONCRETE (o" BASE 21-A COMPACTED 5UBGRADE (COMPACTED TO 95% DENSITY AT OPTIMUM MOISTURE CONTENT, VDOT 5TM-1 METHOD) CONCRETE fi AD (NOT TO SCALE) I"X4"X4'-8" 5LAT5, 2-FINISH NAIL AT TOP AND BOTTOM 2"X4"X4' BEAMS, TOE NAIL TO POST 4"X4"X8' POSTS 1.25" 1, A NOTES: _ I, PRESERVATIVE STAIN ON ALL WOOD. — COLOR TO MATCH THAT OF BLDG. I I I- 2. FINISHED SIDE OF FENCE SHALL FACE m ADJOINING PROPERTY, IF APPLICABLE. �O COMPACTED GRAVEL —_ &' WOOD STOCKADE FENCE DETAIL NOT TO SCALE SET TREE LEVEL AND PLUMB --STRAIGHTEN AFTER SETTLEMENT IF REQUIRED. SET TREE WITH TOP 1/6 OF ROOT BALL ABOVE FINISHED GRADE ENCASE UARE AROUND TRUNCK IN BLACK RUBBER HOSE. SECURE AT HEIGHT ABOVE FINISHED GRADE EQUAL TO 1/3-1/2 OF TREE REMOVE TOP 1/3 OF BURLAP AND CUT ROPE AND/OR REMOVE WIRE BASKET FROM BALL WIRE 012 GAUGE 2" DOUBLE SHREDDED HARDWOOD 3" SOIL SAUCER 3 STAKES BACKPI—L LIGHTLY COMPACTED SETTLING MOUND TYPICAL PLANTING DETAIL-- EVERGREEN TREES (NOT TO SCALE) - - COl„MEIRGIAL/INDUSTRIAL 41. to I 9 I /1 TOWER \ / ACCE55 N \ \ LANE 7 •� 1 - \ EX TREEDNii . - .� / p✓ \ I 1 \ \ k d \ ✓ d CO DEHAVEN U5E: RESIDENTIAL ,o r ON �//yyV�� E : RA � / b 30—A-98D \ / TOWER ACCESS O LANE 6' EVER&REEN PLANTING 10' O.G. f 136' S6�';;73"'E 3— 61 EVER6REEN,PLAWIN6 10 041. / 1 BARBED WIPE FENCE / 100' ` \ W/12' DOUBLE GAT(; \�O' \ I 20 I � /F JOTS UeE: AGRICULTURE ZONE : RA 30-A-1 6(0 211' TOWER '�3 HEIGHT- TYPICAL f \ 10, x 20, ' \ C. PADS, \, l 835' Z W W Z Z W cli o ,n N a� 1 N co CD if) � I 01) I Z x �� W C) O ko � � V) <n N O d � y w v) a v vv ARK D. S TH v No.022837j O� �W sjONAIL W � 0 u Q4 d O ~' rP >-4- 0 � Z 0 W 4., Z O Z wU r—a W s I r' 1�1� DATE: MAY-2002 SCALE: 1" = SO' SCALE: 1" = 50' i DESIGNED BY: DLF FILE NO. 3296 SHEET 2 OF 3 z 0 Lr) O N O O N N 0 +s 3 0 U) w N N O c a �n c a� a� 3 0 c 0 U E E 0 -17 N in a� 0 CONSTRUCTION OF A SILT FENCE (WITH WIRE S UPPOR T) 1. SET POSTS AND EXCAVATE A 4"X4" 2. STAPLE WIRE FENCING TO THE POSTS. TRENCH UPSLOPE ALONG THE LINE OF POSTS. J �i NQI FLOW 4 3. ATTACH THE FILTER FABRIC TO THE WIRE FENCE AND EXTEND IT INTO THE TRENCH. 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. EXTENSION OF FABRIC AND WIRE INTO THE TRENCH. SOURCE: Adapted from Installation of Straw and Fabric Filter Barriers for Sediment Control, PLATE. 3.05-1 Shmood k WTO STONE CONSTRUCTION ENTRANCE EXISTING GROUND 70' MIN. A FILTER CLOTH � 6" MIN. I A I SIDE ELEVATION 12' MIN. 70' MIN. B WASHRACK I f- (REQUIRED) Z- VDOT1 I I ~� POSITIVE DRAINAGE COURSE AGGREGATE B TO SEDIMENT I TRAPPING DEVICE * MUST EXTEND FULL WIDTH I r OF INGRESS AND EGRESS OPERATION PLAN VIEW SECTION A -A RE111rVnIlru 11VM1Mr-IL UKAIN Z)eX.;t SECTION B-B SOURCE: ADAPTED from 1983 Maryland Standards for Soil erosion and Sediment Control, and Va. DSWC Plate 3.02-1 RE5PON51BLE LAND D15 NAME: GERTIFIGATION #: DATE: TURBERI THE RE5PON51BLE LAND DISTURBER 15 THE PARTY RE5PON51BLE FOR GARRIN6 OUT THE LAND DISTURBING ACTIVITY A5 5ET FORTH IN THE PLANS. � l h 10 �� �r' ! ` I N' \ / CY. / • - / i / L>M ice'✓" y v r V f - _ h < / / 1 4 �'! \ r S NES I ' � I \ )_oar ff \ r 409 S 100 0 q 100 ? 200 a° SCALE 1" 100' s EROSION AND SEDIMENT GONTROL NARRATIVE HUNTI NO RI D6E UNMANNED GOMMUN I GATT ON FAG I L I TY Descriptions This project propo5e5 the construction of a new communication tower facility. This project includes the construction of approximately 5 concrete pads for a Iq5' lattice tower and it's mechanical equipment. Existing site conditions: The area to be disturbed under this plan is currently on open area within a partially wooded lot. Adjacent areas: This property bordered on all 51de5 by residential land use in RA zoning. Critical areas: There are no unusual or critical areas at this site. Erosion and sediment control measures: Gontrol of erosion and sedimentation for this Site shall be achieved by installing the following. I. Construction entrance. 2. Gon5truct Silt fence. 3. Soil stabilization through permanent Seeding of any unpaved disturbed areas. Permanent stabilization: Once construction is complete, all disturbed areas not built upon or paved shall be covered with a minimum of four (4) inches of topsoil. Fertilizer, seeding and a blanket of Straw shall be applied to the topsoil. 5tormwater management. There is no proposed stormwater management for this project. Maintenance Programs The erosion and sediment control mea5ure5 installed on the site shall be maintained by performing the following. I. The Site Superintendent Shall inspect all erosion and Sediment control devices after each rainfall and at least daily during prolonged rainfall. Damaged or deficient controls shall be repaired or improved immediately. 2 The Site superintendent shall inspect daily the areas construction activity to Insure erosion control effectivene55. Additional mea5ure5 shall be installed immediately where deficiencies are found. 3. Permanent erosion control measures include the installation of rip rap at storm sewer outfalls and the establishment of grass on exposed surfaces disturbed in the construction process. Erosion and sediment control program I. Hold pre construction meeting on Site. 2. Install construction entrance. 3. Installation of silt fence. 4. Grade the site, install concrete pads. 5. After approval by the inspector, remove the temporary control devices and 5tabilize the areas disturbed during removal. Note: Frederick Gounty retains the right to add and/or modify these erosion and sediment control measures during the construction process, within reason, to ensure adequate protection to the public and the environment. Seeding schedule (soil stabllization)s I. Spread topsoil at a minimum depth of four (4) inches. 2. Incorporate pulverized agricultural limestone into the topsoil of a rate of C`12 Ib5. per 1,000 square feet (2 tons per acre). 3. Fertilize with 10-10-10 fertilizer at a rate of 23 Ibs per 1,000 Square feet (1,000 Ibs per acre). 4. Seed all areas with a seed mix consisting of 67 o Kentucky 31 Tall Fescue and 33% Red Top Glover. 5. Mulch all seeded areas with straw mulch applied at a rate of 3,500 Ib5 per acre, anchored with cutback or emulsified asphalt applied at a rate of 200 gallons per acre. Z W W Z W O CQ C\ ab >— CQab m a .-, �LO Z �' to � LU Cc: Wowl 01 in W a) O w N C4 O � N (`J d- Ln 0 0 Z r z E E O 0 C� C W o 0 Cn C C C C C C v o w W a n. a a THzqj�,T MARK D.v SMITH No.002009 I-1 N W Q Q � E- E-, W z � 4, W O (� oz Z Z �o E-+ Z 0 U Co W w D Q 0-4 Z 11!�w �Q Q � Z C�6 �D O C W DATE: MAY— 2002 SCALE: - AS SHOWN DESIGNED BY: - DLF FILE NO. - 3296 14 SHEET - 3 OF- 3