SITE PLAN CHECKLIST
The checklist below indicates all the information that needs to be submitted as part of the site plan
application. All required information must be submitted prior to the final approval of any site plan.
The Department of Planning and Development will review the application to ensure that it is complete.
If any portion is not included or complete, the site plan application will not be accepted and returned
to the applicant(s).
Site Plan Package
1. One set of approved comment sheets are required from the following review
agencies prior to final site plan approval. It is recommended that applicants contact
the Department of Planning and Development to determine which review agencies
are relevant to their site plan application.
Virginia Department of Transportation (VDOT)
Frederick County Sanitation Authority
Department of Planning and Development
Inspections Department
Frederick County Engineer (Putlic Works)
Frederick County Fre Marshal
Department of Parks and Recreation
2. One copy of the Site Plan application
3. Five Copies of the Final Site Plan for approval
4. One reproducible copy of the Site Plan (if required)
5. A 35mm slide of the Site Plan (if required)
County Health Department
City of Winchester
Town of Stephens Cty
Town of Middletown
Airport Authority
Soil 3 Water Conseriaticn Cistric:
NOTES
File opened
Reference Manual updated/number assigned
D-base updated
File given to Renee' to update Application Action Summary
CLOSE OUT FILE:
Approval (or denial) letter mailed to applicant/copy made for file
File stamped "approved", "denied" or 'withdrawn"
Reference Manual updated
D-base updated
DD File given to Renee' for final update to Application Action Summary
U `Csol\CommMGEiERIC.TRK
Rsrned I I,�'98
0 0.
0 •
lr�ederal Aviation Administration
EASTERN R;JGION, AEA-
BLDG ill, JFK INTL AIRPORT
JAMAICA, NEW YORK 11430
ISSUED DATE: 11/23/99
AERONAUTICAL, STUDY
No: 99-AEA-3577-OE
PRIOR STUDY
No: 99-AEA-2403-OE
JOHN P . ALLEN AIRSPACE CONSULTANT
CFW WIRELESS
P.O. BOX 1008 FL 32035
FERNANDINA BEACH,
OF NO HAZARD TO AIR NAVIGATION
** DETERMINATION **
Administration has completed an aeronautical study
Section 44e1e and, if applicable,
The Federal Aviation U.S.C., art 77, concerning:
under the provisions of 49 U' Regulations,
p
Title 14 of the Code of Federal -R19 8 125-1959.375 MHZ 55 DBM
Description: ANTENNA TOWER
WINCHESTER VA
Location: 3g-11-36.57 NAD 83
Latitude:
Longitude: 078-14-18.80 round level (AGL)
Heights: 140 feet above g
1058 feet above mean sea level (Sdoes not exceed
revealed that the structureation
This aeronautical study 1f any, is (are) met:
ct. n standards and would notn(s),be a hazard to air navig
obstru condit
provided the following kiting are not necessary for
marking and light:
are accomplished
Based on this evaluaWion,everI if marking and/ed and ma
or lighting
aviation safety•pasis, we recommend Advisory it be i4nsG0a1Jintained in
on a voluntary b Circular 70/
accordance with FAA 01 unless:
This determination expires on 05/23/ office or
the issuing
extended, revised or terminate the licensing authorityOf
(a) and an application
(b) the construction n ati as required by the FCC,
the Federal Commuiceitshasmbeen1filedCC) In such case
for a constructionP prescribed by the FCC for
within 6 months n expireston the hdate epe�thebed denies the
the determination expires the date
completion of construction or on
application.
NOTE: REQUEST FOR E XTENSION OF THE EFFECTIVE EPATILEAST 15THIS
DAYSDETERMINATION
TO
MUST BE POSTMARKED OR DELIVERED TO THIS OFF
THE EXPIRATION DATE* on the foregoing
art, ency(ies)
This determination is based, lnheights, f requ
ecific coordiheights, frequency construction
or use
includes sP
changes in coordinates, Any future construction
will void this determination.
description which
and power. Any
of greater power
or alteration,
Post -its Fax Note 7671
Date
s 3/
It of
pages
To /-
From
Co./Dept.
Co.
Phone It
Phone It
Fax It
Fax II
increase in heights, power, or the addition of other
siding requires separate notice to the FAA.
�ansmitters,
determination does include temporary construction equipment such as
This h may be used during actual construction
cranes, derricks, etc., which
e q P ui ment shall not exceed the overall
of the structure. However, which has a height greater than the
heights as indicated above. Equipment re on studied structure requires separate notice to the FAA.
he safe and
tu
This determination concerns tect of this by aircra.ftsandcdoes not trelieve ethe
efficient use of navigable airspaceY to any law, ordinance,
or
sponsor regulation of anynce State, orelocalagovernment body.
regulation Y
A copy of this determination will beforwardedirtlithe
Fedeingauthooimu ications
Commission if the structure is subject
If we can be of further assistance, please contact our office at
718-553-4521. On anyfuture StudysNamberc99cAEAe3577gOEhis matter,
please refer to Aeronautical
X (DNE )
ran T. Jor Jr. `
Specialist, AIRSPACE BRANCH
6
• FILE COPY
February 2, 2000
Mr. Steve Yancey
CFW IntelosNA PCS Alliance
1150 Shenandoah Village Drive
Waynesboro, VA 22980
COUNTY of FREDERICK
Department of Planning and Development
540/665-5651
FAX: 540/ 678-0682
RE: WN206 HI-WAY(Round Hill UMC Property), Site Development Plan #64-99
Dear Steve:
The Frederick County Department of Planning and Development administratively approved the above -
referenced site plan on February 2, 2000. This site plan, for the construction of a 140' monopole tower
at the Round Hill United Methodist Church location, meets all County requirements for development in
the RA (Rural Areas) Zoning District. Furthermore, the site plan is consistent with the conditions and
setback waivers associated with Conditional Use Permit (CUP) #21-99, which was approved by the
Frederick County Board of Supervisors on October 27, 1999. It is important to note that the Leland
Cypress plantings that comprise the required landscape screen must be five (5) feet in height at time of
planting.
I have provided you with several copies of the approved site plan. Please forward these approved plans
to the owner and advise the owner to keep an approved copy for their files. Furthermore, the owner
should ensure that an approved copy is maintained on the construction site throughout the development
process. Once site development has been completed, the owner should contact this office to schedule
an on -site inspection.
Please do not hesitate to contact me should you have any questions or need for elaboration regarding this
letter.
Sincerely,
Christopher M. Mohn
Planner IZ
CMM/rsa
cc: Margaret B. Douglas, Back Creek District Supervisor
June Wilmot, Economic Development Commission
Jane Anderson, Real Estate
Joe Wilder, Public Works
U: Chris�com?noWSile Plan icfw wn206 k64-99.apr.wpd
107 North Kent Street • Winchester, Virginia 22601-5000
—�r�o WINCHESTER REGIONAL AIRPORT
�• 491 AIRPORT ROAD
SERVING THE
TOP OF VIRGINIA WINCHESTER, VIRGINIA 22602
HORo" (540) 662-2422
December 9, 1999
Steve Yancey
CFW Communications
1150 Shenandoah Village Drive
Waynesboro, Virginia 22980
RE: Site Plan Comments — Round Hill Methodist Church
Communications Tower — 140' Monopole
FAA Aeronautical Study No: 99-AEA-2403-OE
Dear Mr. Yancey:
The Winchester Regional Airport Authority offers the following comments on the
above referenced site plan as conditions to be included for approval of this site
plan:
Structure should be marked and lighted in accordance with FAA
Advisory Circular 70/7460-1J, Obstruction Marking and lighting,
Chapters 4, 8 (M-Dual) & 13
2. Copy sent to airport of FAA Form 7460-2, Notice of Actual
Construction or Alteration when filed per specifications outlined in FAA
Aeronautical Study No: 99-AEA-2401-OE
These comments are based on the above referenced FAA study on this
proposed tower and its location. If these conditions and any outlined in the FAA
study are met, the Winchester Regional Airport Authority has no objections to this
site plan.
Should you have any questions or need additional information, please contact
me.
Sincerely,
I-- —P��Mco�
S. R. Manuel
Executive Director
•
•
Mail to:
Winchester Regional Airport
Attn: Executive Director
491 Airport Road
Winchester, VA 22602
(540) 869-2422
Request For Site Plan Comments
Winchester Regional Airport
Hand deliver to:
491 Airport Road
(Route 645, off of Route 522 South)
(540) 869-2422
Please fill out the information as accurately as possible in order to assist the agency with their
review. Please attach one (1) copy of the site plan with this sheet.
Applicant's Name:
Address:
Phone Number:
ame of development
A _, _,n_
v
Gltlt C
Cal) 9 (I- (, l (c), I �,
/or description of the request:
Location of property: / /-7 ljz,
Winchester Regional Airport Comments :
25
S*nt bv:JONN ALLEN AIRSPACE Nov-22-99
29Pn from 9042773631i3409322210___. _ Pa9a 7i 6
f k I •
r
Federal Aviation Administration AERONAUTICAL STUDY
EASTERN REGION, AEA-520 No: 99-AEA-2403-0E
BLDG 111, JFK INTL AIRPORT
JAMAICA, NEW YORK 11430
n
ISSUED DATE: 11/19/99
JOHN P . ALLEN AIRSPACE CON; ULTANTS �)_0 6
4 CFW WIRELESS
P.O. BOX 1006
i FERNANDINA BEACH, FL 32035
: ** DETERMINATION OF NO HAZARD TO AIR NAVIGATION *•
i.
F l The Federal Aviation Administration has completed an aeronautical study t
under the provisions of 49 U.S.C., Section 44718 and, if applicable, ;
�4. + Title 14 bf the Code of Federal Regulations, part 77, concerning:
t i Descr;.ption: ANTENNA TCWER - 1956.1-25-1959.375 MHz ERP 55 DBM
Location: W-7NCHESTER VA is
Latitude: 39-11-36.57 NAD 83
Longitude: 078-14-18.80
Heights: 195 feet above ground level (AGL)
�. ilia feet above mean sea level (AMSL)
This aeronautical study revealed that the structure does not exceed
obstruction standards and wDuld not be a hazard to air navigation
provided the following condition(s), if any, is (are) met:
-As a condition to this determination, the structure should be marked
and/or lighted in accordance with FAA Advisory Circular 70/746o-iJ,
G Obstruction Marking and Lignting, Chapters 4, 8(M-Dual), & 13.
;I
s -It is reC�uired that the en=losed FAA Form 7460-2, Notice of Actual
i Construct on or Alteration, be completed and returned to this office any
time the project is abandoned or;
At least 10 days prior to start of construction
(7460-2, Part I)
Within 5 days after construction reaches its greatest height
}} (7460-2, Part II)
F This determination expires i)n 05/19/01 unless:
i
tj (a) extended, revised or terminated by the issuing office or
().ithe construction is subject to the licensing authority of
the Federal Communications Ccmmission (FCC) and an application
for a construction permit has been filed, as required by the FCC,
within 6 months o:f the date of this determination. In such case
the determination expires on the date prescribed by the FCC for
completion of con,jLruction or on the date the FCC denies the
application.
NQTg; r2£,QUEST FOR EXTENSION OF THE EFFECTIVE PERIOD OF THIS DETERMINATION
WST ZE yoSTMA-RKED OR DELIV3RED TO. THIS OFFICE AT LEAST 15 DAYS PRIOR TO
s ( THE EXPIRATION DATE.
• I -As a to flight safety, it i$
result of this structure being critical
Sent by:JONN ALLEN :IRSPOCE
•
Nov-22-99 12:29Pm
from 9042773631*5409322210 ►age 6/ i
•
required that the FAA be kapt apprised as to the status of this
project. Failure to respo:d to periodic FAA inquiries could invalidate
this determination.
This determination is based, in part, on the foregoing description which
includes specific coordina,'-ee, heights, frequency(ies) and power. Any
changes in coordinates, he-ghts, frequency(ies) or use of greater power
will void this determination. Any future construction or alteration,
including increase in heights, power, or the addition of ether
transmitters, requires separate notice to the FAA.
This determination does include temporary construction equipment such as
cranes, derricks, etc., which may be used during actual construction
of the structure. However, this equipment shall not exceed the overall
heights as indicated above. Equipment which has a height greater than the
studied structure requires separate notice to the FAA.
This deter-ination concerns the effect of this structure on the safe and
efficient use of navigable airspace by aircraft and does not relieve the tj
sponsor of compliance respcnsibilities relating to any law, ordinance, or
regulation of any Federal, State, or local government body.
A copy of this determination will be forwarded to the Federal Communications
Commission if the structure ie subject to their licensing authority.
It we can be of further assistance, please contact our office at
718-553-4521. On any futurs correspondence concerning this matter,
please refer to Aeronautical Study Number 99-AEA-2403-OE.
Frank .1 or an r. ✓ (DNE)
9?ecialie AIRSPACE BRANCH
74b0-2 Attached
� I
1 r ,
4t
i
1 � I •
I
j'
F
t
F
c�
u
Federal Aviation Administration
EASTERN RF-,GION, AEA-520
BLDG iil, JFK INTL AIRPORT
JAMAICA, NEW YORK 11430
AERONAUTICAL STUDY
No: 99-AEA-3577-OE
PRIOR STUDY
No: 99-AEA-2403-OE
ISSUED DATE: 11/23/99
JOHN P . ALLEN AIRSPACE CONSULTANT
CFW WIRELESS
P.O. BOX 1008 FL 32035
FERNANDINA BEACH,
** DETERMINATION OF NO HA
ion has completed
TO AIR NAVIGATION
study
Section 44718 and,
an aeronautical
The Federal Aviation Administratart 77, if concerning:
under the provisions of 49 U• ulations, p
Title 14 of the Code of FederalR1958 125-1959.375 MHZ 55 DBM
Description: ANTENNA TOWER -
WINCHESTER VA
Location: 39-11-36.57 NAD 83
Latitude: - 07814-18•80
Longitude: 1feet above ground level (AGL)
Heights:
1058 feet above mean sea level (AMSdoes not exceed
revealed that the structure navigation
This aeronautical study if any, is(are) met:
ruction standards and WOtion(s),be a hazard to air
obst condi
provided the following lighting are not necessary for
marking and lig are accomplished
Based on this evaluation, if marking and/or lighting
aviation safety. However,, we recommend it be7a1Jinstlle
Advisory ircular d and maintained in
on a voluntary C70 /460
accordance with FAA less:
This determination expires on 05/23 /01 unoffice or
the issuing
(a) extended, revised or terminated the licensing authority of
application
(b) the construction n Subjectas required by the FCC,
the Federal Communicatmitshas Commission
filed, andanaPP In such case
for a construction per determination..
bed .. the FCC for
within 6 months °fexhreston the of e1dateepermihe FCC denies the
the determination p
completion of construction or on the date
application.
NOTE: REQUEST FOR E XTENSION OF THE EFFECTIVE
CEPERIOD
LEAST 15THIS
DAYSTPR� DETERMINATION
MUST BE POSTMARKED OR DELIVERED TO THIS OFF
THE EXPIRATION DATE. the foregoing
in :)art, on ies)
includes specific coordinates, eights, frequency(
This determination is based,
uency(ies) or use
heights, freq
Any future
will void this determinatconstruction
changes in coordinates, ion.
description which
and power. Any
of greater power
or alteration,
• 0
including increase in heights, power, or the addition of other
transmitters, requires separate notice to the FAA.
stru
This determination does include tempoderricks, etc., wtemporary conacoaleeonstructionh as
cranes, which may be used during
of the structure. However, this equipment shall not exceed the overall
int which has a height greater than the
heights as indicated above. Equpme
studied structure requires separate notice to the FAA.
truture on
he safe and
This determination concerns rs effaceeby ai.rcraftct of thissandcdoes nott
trelieve the
efficient use of navigable a plaw
sponsor of compliance responsibilitoTelocalagovernmentybody, ordinance, or
regulation of any Federal, State,
A copy of this determination will becforwardt toed tlicensingFedthe
eral autho�Tty.ications
Commission if the structure i 7
If we can be of further assistance, please contact our office at
718-553-4521. On anStudysN�mberc99CAEAe3577gOEhis matter,
please refer to Aeronautical
ran T. Jor Jr. G0
Specialist, AIRSPACE BRANCH
• 0
REQUEST FOR CONDITIONAL USE PERMIT COMMENTS
Virginia Department of Transportation
Attn: Resident Engineer
14031 Old Valley Pike
Edinburg, Virginia 22824
(540) 984-5600
The local office of the Transportation Department is located at 1550 Commerce St. in Winchester
if you prefer to hand deliver this form.
Applicant's name, address and phone number:
pall CG 5-#0, 4— •7z q (0
Name of development and/or description of the request:
l 40 mnnDY,)DI e w l �h W- q ZQ"X 20"-�/
Location: _
Va. Dept. of Transportation Comments:
No objection to conditional/special use permit for this property. Existing
entrance is adequate for proposed use. However, should use ever expand in
the future the entrance may have to be ungraded to VDOT minimum commercial
standards.
VDOT Signature and Date: ' Z3- 75r
(NOTICE TO RESIDENT ENGINES *PLEASE REiIVAN THIS FORM TO APPLICANT.)
NOTICE TO APPLICANT
It is your responsibility to complete this form as accurately as possible in order to assist the agency
with their review. Also, please attach two (2) copies of your application form, location map and all
other pertinent information.
COUNTY of FRE ERICK
Department of Planning and Development
540/665-5651
FAX: 540/678-0682
December 13, 1999
Mr. Steve Yancey
CFW Intelos/VA PCS Alliance
1150 Shenandoah Village Drive
Waynesboro, VA 22980
RE: WN206 Hi -Way Tower (Round Hill UMC Property), Site Development Plan B64-99
Dear Steve:
I have had the opportunity to review the above referenced site plan submitted to our department on
December 1, 1999. The following comments are offered and should be addressed during the revision
of this site plan. I have also marked the enclosed plan for your use.
1) Please include the name, address, and phone number of the property owner on the site plan.
2) Please include the name, address, and phone number of the developer on the site plan.
3) Please identify the setback waiver(s) granted for the subject project by the Frederick County
Planning Commission.
4) Please provide a space labeled "Approved by the Zoning Administrator" for the approval
signature and date of approval. A statement should be provided with this space indicating that
the site plan will be valid for a period of five years from the date of approval.
5) Please indicate the use of the properties adjoining the subject parcel.
6) Please delineate the setbacks provided for the proposed tower relative to the boundaries of
the Kowalski and Gardiner properties, as well as the Trinity Lane right-of-way. These
setbacks should correspond with the reduced setback distances permitted through the waiver
granted by the Frederick County Planning Commission, where applicable. It is recommended
that the property lines shared with these parcels and the right-of-way boundary be shown on
the lease parcel detail, which may necessitate an increase in scale. Furthermore, a table
indicating the standard setback(s) applicable to the tower prior to waiver approval should be
provided on the site plan. Please refer to the example provided with the review comments
for the Patton property site (WN 202) when preparing this table.
107 North Kent Street o Winchester, Virginia 22601-5000
•
Page 2
Mr. Steve Yancey
Re: WN206 Hi -Way (Round Hill UMC Prop.) Site Plan Review
December 13, 1999
7) Please delineate the landscaping intended to screen the subject facility in accordance with the
conditions of Conditional Use Permit (CUP) #21-99 (approved October 28, 1999). A plant
schedule specifying the type, quantity, and size at time of planting (height and/or caliper)
should also be included on the site plan. Please provide a detail of the device proposed to
satisfy the opaque requirement of the applicable CUP condition.
After you have revised the site plan, please resubmit one copy so that I may verify the information
contained on the plan. I will then need all approved review agency comment sheets and five copies
of the final site plan for approval. Comment sheets are required from the following agencies: the
Virginia Department of Transportation, the Winchester Regional Airport, and the Frederick County
Inspections Department.
Please contact me if you have any questions regarding this letter.
Sincerely,
Christopher M. Mohn
Planner II
CMM/rsa
Enclosure
U: UirislconintonlSife Plnnlcjw wn206 ft64-99.spr.xpd
C� J
•
•
SITE PLAN CHECKLIST
LC�� - Z•W���
The checklist below indicates all the information that needs to be submitted as part of the site plan
application. All required information must be submitted prior to the final approval of any site plan.
The Department of Planning and Development will review the application to ensure that it is complete.
If any portion is not included or complete, the site plan application will not be accepted and returned
to the applicant(s).
Site Plan Package
1. One set of approved comment sheets are required from the following review
agencies prior to final site plan approval. It is recommended that applicants contact
the Department of Planning and Development to determine which review agencies
are relevant to their site plan application.
Virginia Department of Transportation (VDOT)
Fredenck County Sanitation Authority
Department of Planning and Development
Inspections Department
Fredenck County Engineer (Public Works)
Fredenck County Fire Marshal
Department of Parks and Recreation
2. One copy of the Site Plan application
3. Five Copies of the Final Site Plan for approval
4. One reproducible copy of the Site Plan (if required)
5. A 35mm slide of the Site Plan (if required)
County Health Department
City of Winchester
Town of Stephens City
Town of Middletown
-Airport Authority
Soil & Water Conservation District
Request for Street Name
8
Site Plan Information Checklist
The following information must be included on your site plan. If your site plan is incomplete or
is missing information, it will not be reviewed and returned to you for revisions.
Administrative Information
Y N
1.
Name of proposed development.
2O
Name, address, and phone number of owner.
Name, address, and phone number of developer.
designer.
J
4.
Name, address, and phone number of
5.
Certificate of surveyor, engineer, or architect.
Date plan prepared and date of revisions.
OA
listing of all conditions placed on the site as a result of a
conditional use perm t or conditional zonin ap roval.
"Approved for
A space labeled by the Zoning Administrato the
approval signature and date of approval.
9.
A description of setbacks or conditions placed on the site as a result
of a variance approval. (Reference the variance
application number.)
General Site Information
Y N
Location map (scale 1:2000)
Magisterial District
Scale of site plan (not to exceed 1:50)
North Arrow
Zoning of site
Use, zoning, and Property Identification Number (PIN#) of all
adjoining properties. This includes properties located across right-
of-ways, streams, and railroad tracks.
Surveyed boundaries for all lots and parcels.
General Site(con't)
Y
N
17.
Acreage of all lots included in the plan.
�8
The location and dimensions of all required setbacks and yard
areas.
19.
The location and type of all dwelling units.
N�R
20.
Location and description of all recreation facilities.
21.
Location of sidewalks and pedestrian ways.
22.
Location and area of common open space.
23.
The location, height, and dimensions of all signs.
24.
Location, height, and specifications of outdoor lighting fixtures.
25.
Location and nature of outdoor storage areas.
26.
Location of outdoor trash receptacles and dimensions of structure
(fencing, etc.) required to enclose receptacles.
Building
Information
Y
N
27.
The height of all buildings and structures.
28.
Location of all buildings, structures and uses.
29.
The proposed use of each building, structure and area.
N
30.
Ground floor area and total floor area of all buildings with FAR
calculations for commercial and industrial zoning districts.
Roads
Y N
31. Name and number of existing and planned streets on and adjoining
the site
32. Location of existing and planned streets on and adjoining the site.
33. Posted speed limit of existing adjacent roads.
34. Location and dimensions of all proposed entrances from public
right-of-ways.
35. Location of all entrances on adjoining roads within 200 feet of the
proposed or existing entrance.
36. Dimensions, boundaries, width, pavement, and construction of
planned roads.
•
•
Utilities
Y N
3T Location of all utilities, including sewer and water lines with the size
of lines, mains, and laterals.
38. Location and width of all easements, including access, utility, and
drainage easements.
39. Location and nature of fire lanes, fire hydrants, and all other
facilities necessary to meet Fire Code requirements.
Parkin
Y N
40. Calculations describing the required number of parking and loading
spaces.
41. Location and dimensions of all parking and loading spaces,
driveways, parking aisles, curbing and other features to be used.
42. Location and dimension of all disabled parking spaces and
ramps.
Natural Features
Y N
43. Existing and finished contour lines.
44. Location of steep slopes, woodlands, floodplains, wetlands,
sinkholes, and other environmental features.
45. Location of streams and drainage ways.
•
Landscaping
Y N
46
47
Erosion and Sediment Control
Y N
48
49
Landscaping plan describing location and types of plants to be \
used.
Location of required buffers and screening with cross sections orb
profiles.
A stormwater management plan with run off calculations and
location and description of facilities to be used.
Soil erosion and sedimentation control plan describing the location
and methods to be used to minimize erosion and sedimentation
during development.
12
Request For Site Plan Comments
Department of Planning and Development
Mail to:
Hand deliver to:
Department of Planning and Development
107 N. Kent Street
Attn: County Planner
Fourth Floor
107 North Kent Street
Winchester, VA
Winchester, VA 22601
(540) 665-5651
(540) 665-5651
Please fill out the information as accurately as possible in order to assist the agency with their
review. Please attach two (2) copies of the site plan with this sheet.
Applicant's Name: CI,/'W c_"
Address:
Phone Number:
Name of development and/or description of the reque
c
Location of property: 60
rvl h A h_ l
Planning and Development's Comments:
16
•
0
SITE PLAN APPLICATION
Department of Planning and Development Use only.
Date application received 12-1-73 Application # 0�7:qq
Complete. Date of acceptance
Incomplete. Date of return.
L
1. Project Title:
2. Location of Property ZxJ 0111 LYl r SLd.tirA
(street address) I b I --�V i V, IL, Kok �,
(k4 C, v, , V 4
3. Property Owner: Sa N,k-f-, Gt Ct tyv (—
Address:
Telephone: C Z% 7- Z 3 I
4. Applicant/Agent Of Sr1k I vs UA hGS
Address �k' r140aC UI
��CtUr�PS%OVy'A 221)13J
COIL C a o, c
Telephone;,,
G /
5. Designer,
Address:
Telephone: (_,�A0) g410 - 1895
Contact: v��tie akctq
0
0
7a
7b
Is this an original or revised site plan?
Total acreage of parcel to be developed:
Total acreage of parcel:
8. Property Information:
Original t/ Revised
1100 �-F
p .
a)
Property Identification Number:
SZ " A I 17 h
b)
Current Zoning:
Giu,Lr�Je
c)
Present Use:
d)
Proposed Use:
(QM0YJZ. 16-/) 1P �
L-2, , ietL+I
e)
Adjoining Property Use(s)
I�GXSI/QP j'►ct ��l(S�k� �5
t.�a Ctu�-
f)
Adjoining Property Identification Number(s)
A-3
1 4 4—
g)
Magisterial District(s)
t►n bl'0
I have read the material included in this package and understand what is required by the
Frederick County Planning Department. I also understand that all required material will be
complete prior to the submission of my site plan.
Signature:
Date:
7
SITE PLAN CHECKLIST
The checklist below indicates all the information that needs to be submitted as part of the site plan
application. All required information must be submitted prior to the final approval of any site plan.
The Department of Planning and Development will review the application to ensure that it is complete.
If any portion is not included or complete, the site plan application will not be accepted and returned
to the applicant(s).
Site Plan Package
1. One set of approved comment sheets are required from the following review
agencies prior to final site plan approval. It is recommended that applicants contact
the Department of Planning and Development to determine which review agencies
are relevant to their site plan application.
Virginia Department of Transportation (VDOT)
County Health Department
Frederick County Sanitation Authority
City of Winchester
Department of Planning and Development
Town of Stephens City
Inspections Department
Town of Middletown
Frederick County Engineer (Public Works)
�✓ Airport Authority
Frederick County Fire Marshal
Soil & Water Conservation District
Department of Parks and Recreation
Request for Street Name
2. One copy of the Site Plan application
3. Five Copies of the Final Site Plan for approval
4. One reproducible copy of the Site Plan (if required)
5. A 35mm slide of the Site Plan (if required)
•
•
The following information must be included on your site plan. If your site plan is incomplete or
is missing information, it will not be reviewed and returned to you for revisions.
Administrative Information
Y N
vl�
1.
Name of proposed development.
2.
Name, address, and phone number of owner.
—��—
3.
Name, address, and phone number of developer.
4.
Name, address, and phone number of designer.
--7
5.
Certificate of surveyor, engineer, or architect.
6.
Date plan prepared and date of revisions.
c/
7.
A listing of all conditions placed on the site as a result of a
conditional use permit or conditional zoning approval.
8.
A space labeled "Approved by the Zoning Administrator" for
the approval signature and date of approval.
9.
A description of setbacks or conditions placed on the site as a
result of a variance approval. (Reference the variance
application number.)
General Site Information
Y N
it
10.
Location map (scale 1:2000)
_1
11.
Magisterial District
12.
Scale of site plan (not to exceed 1:50)
13.
North Arrow
l�
14.
Zoning of site
15.
Use, zoning, and Property Identification Number (PIN#) of all
adjoining properties. This includes properties located across
right-of-ways, streams, and railroad tracks.
for lots
16.
Surveyed boundaries all and parcels.
9
General Site (con't)
Y N
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
Acreage of all lots included in the plan.
The location and dimensions of all required setbacks and yard
areas.
The location and type of all dwelling units.
Location and description of all recreation facilities.
Location of sidewalks and pedestrian ways.
Location and area of common open space.
The location, height, and dimensions of all signs.
Location, height, and specifications of outdoor lighting fixtures.
Location and nature of outdoor storage areas.
Location of outdoor trash receptacles and dimensions of
structure (fencing, etc.) required to enclose receptacles.
Building Information 4
Y N
27. The height of all buildings and structures.
28. Location of all buildings, structures and uses.
29. The proposed use of each building, structure and area.
30. Ground floor area and total floor area of all buildings with FAR
calculations for commercial and industrial zoning districts.
Roads
Y N
31. Name and number of existing and planned streets on and
adjoining the site.
32. Location of existing and planned streets on and adjoining the
site.
33. Posted speed limit of existing adjacent roads.
34. Location and dimensions of all proposed entrances from public
right-of-ways.
10
A 1
!7
P
Utilities
Y
N
Parking
Y N
Natural Features
Y N
35. Location of all entrances on adjoining roads within 200 feet of the
proposed or existing entrance.
36. Dimensions, boundaries, width, pavement, and construction of
planned roads.
37. Location of all utilities, including sewer and water lines with the
size of lines, mains, and laterals.
38. Location and width of all easements, including access, utility,
and drainage easements.
39. Location and nature of fire lanes, fire hydrants, and all other
facilities necessary to meet Fire Code requirements.
40. Calculations describing the required number of parking and
loading spaces.
41. Location and dimensions of all parking and loading spaces,
driveways, parking aisles, curbing and other features to be used.
42. Location and dimension of all disabled parking spaces and
ramps.
43. Existing and finished contour lines.
44. Location of steep slopes, woodlands, floodplains, wetlands,
sinkholes, and other environmental features.
45. Location of streams and drainage ways.
0
Landscaping
Y N
46. Landscaping plan describing location and types of plants to be
used.
47. Location of required buffers and screening with cross sections or
profiles.
Erosion and Sediment Control _
Y N
48. A stormwater management plan with run off calculations and
location and description of facilities to be used.
49. Soil erosion and sedimentation control plan describing the
location and methods to be used to minimize erosion and
sedimentation during development.
12