HomeMy WebLinkAbout10-01 Moxon Timbers, Inc. (new lumber kilns & storage bldgs.) - Back Creek - Backfile1
SITE PLA*J CHECKLIST
The checklist below indicates all the information=that needs to be. -submitted as part of the site plan
application. All required information must.be submitted prior to the final approval of any site plan.
The Department of Planning and Development will review the application to ensure that it is complete.
If any portion is not included or complete, the site- plan application will not be accepted and returned
to the applicant(s).
Site Plan Package
P� 1. One set of approved comment sheets are required from the following review .
agencies prior to final site plan approval. It is recommended that applicants contact
the Department of Planning and Development to determine which review agencies
are relevant to their site plan application.
2.
3.
4.
Virginia Department of Transportatio?ff OT) L�lzlw
-4�
¢c �ir�j ,Gf'raszte necks-vr�T , dc1.zy)
Frederick Co my Sanitation Authority
Department of Planning and Development
Inspeclions Department ///,�o/
Frederick County Engineer (Public Works) 114` 0/
Frederick County Fire Marshal
A144 Department of Parks and Recreation
1
One copy of the Site Plan application
Five Copies of the Final Site Plan for approval
�/ County Health Department
047'e, City of Winchester 3/8'1,, /
Town of Stephens City
T Town of Middletown
4 Airport Authority
—44 Sol & Water Conservation District
One reproducible copy of the Site Plan (if required)
5. A 35mm slide of the Site Plan (if required)
i
NOTES
File opened
Reference Manual updated/number assigned
D-base-updated
3• Z ,O/ File given to Renee' to update Application Action Summary
CLOSE OUT FILE:
V- Approval (or denial) letter mailed to applicant/copy made for file
File stamped "approved', "denied" or *Mhdrawn"
Reference Manual updated
D-base updated
File given to Renee' for final update to Application Action Summary
ds.A--- '
UAC=ncormnon%c6-qMc1-wc
R Yiwd 11rIms
4
t1c)OC)a00
376. c)� -(! r 7 - -i
CA C- re—S
CASH
RECEIPT Date 3 1 i— �� l 002124
Received From
``Address, 1
wo►u > lt� tars$ l%
�@ Fo
x= o ACCOUNT HOW•
] W' CASH
M:A
AMT MID CHECK
BALANCE PEER By
��� U%��
FREDERICK AELTNTY DEPARTMENT OF PLANNII.qW DEVELOPMENT
Site Inspection Form
Permit Holder Name
Site Plan or Subd' ')n P an Number
�'• , 1 /?n/ ll/• 1 n
Building Permit Number
GENERAL INFORMATION
Property Identification Number (PIN)
Lo ion
Contact Informat'on
INSPECTION OF ROADS, DRIVEWAYS & TRAVEL AISLES (Check when completed - note all incomplete work):
Street & Traffic Signs
Striping
Surface Material
Comment
Inspector
Inspector
Sidewalks & Lighting
Dimensions
Overall Layout
Date Verified Incomplete
Date Verified Complete _
INSPECTION OF PARKING, MANEUVERING AREAS & LOADING AREAS (Check when completed - note all incomplete work):
Number of Spaces
Striping
Surface Material
Comment
Inspector
Inspector
Sidewalks & Lighting
Dimension of Spaces
Overall Layout
Date Verified Incomplete
Date Verified Complete
INSPECTION OF LANDSCAPING IMPROVEMENTS (Check when completed - note all incomplete work):
Number of Trees Number of Shrubs
Size of Plants �— Species of Plants
Soil Stabilization Seeding
Screens V Overall Layout
Comments .11led f 5'0f L
Inspector
Inspector x /i
/ N'/ 7e \,
Date Verified Inc [gplete
Date Verified C"
INSPECTION OF OTHER IMPROVEMENTS (Check when completed - note all incomplete work):
Setbacks
Proffered Conditions
Signs
Comments
Inspector
Inspector
Recreational Facilities
Preservation Areas
Curb & Gutter
Date Verified Incomplete
Date Verified Complete _
"=j'RIat COMM DBPARTIi M OF PLKMXNG & DXM0PNXNT - FINAL SITS APPROVAL
Signature
Date of Approval
Is site approval contingent on a monetary guarantee? Yes* No Bond Number
(*If yes, all site improvements noted on this form must be complete prior to the release of a monetary
guarantee. In addition, all relevant review agencies shall provide final site approval. A checklist
of these agencies is provided below for documentation purposes.)
Fire Marshal Virginia Department of Transportation
Building Inspections Sanitation Authority
Public Works City of Winchester
Parks & Recreation other ( )
(Please date & initial when all site work is complete & all relevant review agencies have approved)
Date Monetary Guarantee Released Initials
0
COUNTY of FREDERICK
Department of Planning and Development
540/665-5651
FAX: 540/ 665-6395
May 10, 2001
Mr. Jason J. Thomas, P.E.
Greenway Engineering
151 Windy Hill Lane
Winchester, Virginia 22602
RE: Administrative Approval of Site Plan # 10-01;
Moxon Timbers, Proposed Kilns and Storage Buildings;
Property Identification Number (PIN) 63-6-5
Dear Jason:
The Frederick County Department of Planning and Development administratively approved the above
referenced site plan on May 10, 2001. The site plan calls for the construction of a two additional kilns and two
storage buildings. Development is planned to be implemented in three phases. During phase one the two kilns
will be constructed, along with a gravel outdoor storage area. To meet the requirements for outdoor storage,
a double row of evergreen trees will be planted to screen the property from adjoining roads and properties. Part
of the screen will be planted in the Virginia Department of Transportation's right-of-way because of the
existence of a major power line along the north property line. Negotiations with VDOT have been made to
allow the tree plantings, and preliminary approval has been granted. Phase Two will include the construction
of a 12,000-square-foot storage building and a new loading space. The second storage building, also 12,000
square feet, will be added in phase three. The site plan meets all requirements for development in the M 1(Light
Industrial District). Additional requirements are specified on the site plan for each phase of development.
I am providing you with five copies of the approved site plan. Please forward these to the appropriate
representative for Moxon Timbers. Furthermore, please advise the owner that a copy should be kept for future
reference and an approved copy must be kept on the construction site throughout the development process.
Once site development is complete, the owner needs to contact this office to schedule an on -site inspection.
Please do not hesitate to contact me if you have any questions or concerns.
Sincerely,
�I
7
Jeremy F. Camp - Planner II
JFC/ch
Enclosure
cc: Jane Anderson; Real Estate
IlSystem 2hshare with fiSite Plan Review Q0011Moxen Timbers WpprovalLetterSP10 Ol.wpd
107 North Kent Street • Winchester, Virginia 22601-5000
•
GREENWAY ENGINEERING
151 Windy Hill Lane
Winchester, Virginia 22602
Fnindrd in U71
T R A N S M I T T A L
Project Name
File No.
Date
Moxon Timbers
1058
May 8, 2001
To: Frederick Co Planning
Attn: Jeremy Camp
Copied:
From: Jason Thomas/ds
GREENWAY ENGINEERING
Phone: 540-662-4185
Fax: 540-722-9528
Remarks: F Urgent 17'For Your Review 1. As You Requested 1� Please Comment
Allessage:
Jeremy,
Attached are 7 copies of the site plan for the above project for your review and signature. The
comments from Frederick County Fire Marshall are also included.
Call with any concerns.
DECEIVED
MAY O 8 ZOO]
DEPT. OF PLANNIN6,1DEVELOPMENT
Engineers Surveyors
Telephone 540-662-4185 FAX 540-722-9528
greenway@visualli nk. com
i
Request For Site Plan Comments
Frederick County Fire Marshal
Mail to:
Frederick County Fire Marshal
Attn: Fire Marshall
107 North Kent Street
Winchester, VA 22601
(540) 665-6350
RECEIVED MAY - 2 2000
sroo .8 t4QV)
Hand deliver to:
107 N. Kent Street
First Floor
Winchester, VA
(540) 665-6350
Please fill out the information as accurately as possible in order to assist the agency with
their review. Please attach two (2) copies of the site plan with this sheet.
Applicant's Name: Greenway Engineering
eering
Address: 151 Windy Hill Lane, Winchester, VA 22602
Phone Number: (540) 662-4185
Name of development and/or description of the request: Moxon Timbers Inc. Site
Plan Revision Former owner Dawson Investments Inc.
Location of property: On the corner of Industrial Drive (Route 880), and Development
Lane (Route 881), Back Creek District .
Fire Marshal's Comments:
and Rescue Dept. use only
received Date revision received
Incomplete
Date reviewed S 3-ate Date review wed
Signature and Date �� -
Signature and Date (revision
RECEIVE®
MAY 0 8 2001
DEPT, OF PLAN . j%p&c,:L0pAtEW
Date approved-
COUNTY OF FREDERICK, VIRGINIA
FIRE MARSHAL'S OFFICE
LAND DEVELOPMENT COMMENTS
Control No. SPOO-0017 Date Received 5/2/2000 Date Reviewed 5/3/2000
Applicant Greenway Engineering Plan Rev. Date:
Address 151 Windy Hill Lane
Winchester, Va. 22602
Project Name Moxon Timbers- Kiln Phone No. 540-662-4185
Type of Application Site Plan Current Zoning M-1
1st Due Fire Co. 11 1st Due Rescue Co. 11 Election District Back Creek
Tax I.D. No. 63-6-5
RECOMMENDATIONS
Automatic Sprinkler SystemXX Residential Sprinkler System
Automatic Fire Alarm SystemXX Other
REQUIREMENTS
Emergency Vehicle Access
Adequate Inadequate XX Not Identified
Fire Lanes Required Yes XX No
Comments : Previous site plan comments required "Fire Lane" signage
around proposed structure. None found during site visit.
Roadway/Aisleway Widths Adequate Inadequate XX Not Identified
Special Hazards Noted Yes XX No
Comments Outside storage within 15 feet of buildingiolation of F-2103.3 of
Statewide Fire Prevention Code, Storage in front of fire hydrant, must have 20' clear.
Hydrant Locations Adequate XX Inadequate Not Identified
Siamese Location Adequate Inadequate Not Identified XX
Additional Comments Attached? Yes No XX
Plan Approval Recommended? Yes XX No
Signature -=+��• Title
RECEIVE®
MAY 0 0 2001
DEPT, OF PLANNING/DEVELOPMENT
0 •
GREENWAY ENGINEERING
151 Windy Hill Lane
Winchester, Virginia 22602
Founded in 1971
T R A N S M I T T A L
Project Name: Moron Timbers
Pile No.: 1058
Date: May 1, 2001
To: Frederick Co Planning
Attn: Jeremy Camp
Copied: Shayne Lachlan -Moron Timbers
From: Jason Thomas&
GREENWAY ENGINEERING
Phone: 540-662-4185
Fax: 540-722-9528
Ren-kirks: ❑ Urgent ❑ For Your Review ❑ As You Requested ❑ Please Comment
Message:
Jeremy,
Attached are 2 copies of the revised site plan per County comments, cover letter in response to
these comments, and a copy of the e-mail from VD0T- N -C-o vi \,uviouS
a9�v��ces are- also i ncIc)deob
Call with any concerns.
MAY 0 `I� 2001
DEPT. OF PLANNINGIDEVELOPMENT
Engineers Surveyors
Telephone 540-662-4185 FAX 540-722-9528
grcenway a visuallink.com
Jason Thomas
From:
Melnikoff, Steve [SMelnikoff@VDOT.STATE.VA.US]
Sent:
Monday, April 30, 2001 8:41 AM
To:
'Jason Thomas @ Greenway Engineering'
Cc:
Melnikoff, Steve
Subject:
FW: Moxon Timbers & Truswood ,
> -----Original Message-----
• From: Funkhouser, Rhonda On Behalf Of Melnikoff, Steve
> Sent: Tuesday, April 24, 2001 7:58 AM
> To: 'Mark Smith @ Greenway Engineering'
> Cc: Dove, Roger; Melnikoff, Steve; Ingram, Lloyd; Hawkins, Robert
> Subject: Moxon Timbers & Truswood
> «... >>
> DEPARTMENT OF TRANSPORTATION
> 14031 Old Valley Pike
> Edinburg, Virginia 22824
> April 24, 2001
> Mr. Mark Smith
> C/O Greenway Engineering
> 151 Windy Hill Lane
> Winchester, VA 22602
> Ref: Proposed Screening, Moxon Timbers & Truswood
> Route 37, Frederick County
> Dear Mr. -Smith:
> We have reviewed the referenced proposal and have the following
comments:
> * The applicant submits a cooperative planting agreement between
VDOT
> and the developer for our review and that the applicant assumes all
future
> maintenance of these trees.
> * Plant one row of White Pine with the second row to be Norway
Spruce.
> * The row closest to the right-of-way fence should be 10, from the
> fence to allow access of our mowers.
> * The second row should not be closer than 20' from the fence and
no
> more than 10' from the first row.
> * The trees in each row should be offset from the trees in the
other
> row.
> Should this be agreeable with your client, please prepare the Planting
> Agreement for our review.
> Steven A. Melnikoff
> Transportation Engineer
> VDOT - Edinburg Residency
> Permit & Subdivision Section
> 14031 Old Valley Pike
> Edinburg, VA 22824
1
COUNTY of FREDERICK
Department of Public Works
540/665-5643
rA X : 540/ 678-0682
January 29, 2001
Mr. Jason J. Thomas, P.E.
Greenway Engineering
151 Windy Hill Lane
Winchester, Virginia 22602
Re: Site Plan Comments - Moxon Timbers
Frederick County, Virginia
Dear Jason:
Upon review of the revised site plan dated January 18, 2001, all of our previous comments
have been addressed. Therefore, we recommend approval of the subject site plan.
If you have any questions, do not hesitate to contact me
Sincerely,
Joe C. Wilder
Engineering Technician
cc: Frederick County Planning Department
file
107 North Kent Street • Winchester, Virginia 22601-5000
r • •
Request For Site Plan Comments
Frederick County Inspections Department
Mail to:
Frederick County Inspections Dept.
Attn: Building Official
107 North Kent Street
Winchester, VA 22601
(540) 665-5650
Hand deliver to:
107 N. Kent Street
Fourth Floor
Winchester, VA
(540) 665-5650
Please fill out the information as accurately as possible in order to assist the agency with their review.
Please attach one (1) copy of the site plan with this sheet.
Applicant's Name: Greenway Engineering
Address: 151 Windy Hill Lane Winchester, VA 22601
Phone Number: (540) 662-4185____
Naive of development and/or description of the request: Moxon Timbers, Inc site plan addition
Location of property: Corner of Industrial Drive (Rt 880) and Development Lane (Rt 881)
Inspections Department's Comments: Comments are on the back of this form.
r • •
Buildings shall comply with The Virginia Uniform Statewide Building Code and
sections 311, use group S (Storage) for the lumber building and section,312,
use group U (Utility) of The BOCA National Building Code/1996. Other codes
that apply are CABO A 117.1-92 Usable and accessible Buildings and Facilities.
HC access shall be provided to the storage buildings and accessible restrooms
shall be provided to the employee's with in 500' according to the International
Plumbing Code.
Request for Site Plan Comments
Virginia Department of Transportation
Mail to:
Virginia Department of Transportation
Attn: Resident Engineer
14031 Old Valley Pike
Edinburg, Virginia 22824
(540) 984-5600
Hand deliver to:
Virginia Department of Transportation
1550 Commerce Street
Winchester, VA
(540)7 22-3460
Please fill out the information as accurately as possible in order to assist the Virginia
Department of Transportation with their review. Please attach five (5) copies of the site plan
with traffic generation data and drainage calculations with this sheet.
Applicant's Name: Greenway Engineering
Address: 151 Windt/ Hill Lane, Winchester,VA 22602
Phone Number: (540) 662-4185
Name of development and/or description of the request: Moxon Timbers, Inc. site plar
addition
Location of property: Corner of Industrial Drive (Rt 880) and Development Lane (881)
Virginia Department of Transportation's Comments:
No objection to this site plan. Present entrance(s) is adequate for proposed
improvements. Should business ever expand in the future, entrance(s) may
need to be upgraded.
ransporcaEion Lngine
Request For Site Plan Comments
Frederick County Fire Marshal
Mail to:
Frederick County Fire Marshal
Attn: Fire Marshall
107 North Kent Street
Winchester, VA 22601
(540) 665-6350
• RECEIVED MAY - 2 2001
SPOO-o ool#)
Band deliver to:
107 N. Kent Street
First Floor
Winchester, VA
(540) 665-6350
Please fill out the information as accurately as possible in order to assist the agency with
their review. Please attach two (2) copies of the site plan with this sheet.
Applicant's Name: Greenway Engineering
Address: 151 Windy Hill Lane, Winchester, VA 22602
Phone Number: _(540) 662-4185
Name of development and/or description of the request: Moxon Timbers Inc. Site
Plan Revision. Former owner Dawson Investments Inc.
Location of property: On the corner of Industrial Drive (Route 880), and Development
Lane (Route 881), Back Creek District .
Fire Marshal's Comments:
Fire and Rescue Dept. use only
received S-1 -1.0c10 Date revision received
Incomplete
Date reviewed S 3-ate Date reviewed'�1°`\
Signature and Date --
Signature and Date (revision)
Date approved S-
Request For Site Plan Comment
. City of Winchester
Mail to:
Winchester Planning Dept.
Attn: Planning Director
15 N. Cameron Street
Winchester, VA 22601
(540) 667-1815
Hand deliver to:
c� TruTe� 15 N. Cameron Street
Rouss City Hall .
Winchester, VA
(540) 667-1815
Please fill out the information as accurately as possible in order to assist the agency with their
review. Please attach one (1) copy of the site plan with this sheet.
Applicant's Name:.
Address: /S/ G�/error �rru`� ,stir',. �/i�,�rc-s -ram,, LA z z6 07
Phone Number: s`»-6�z-Y/��"
• Name. of development and/or description of the request:oxa�,
�iTE moo.! o0�,oi7701-/
Location of property: C
... '.
City of Winchester's Comments: re C- O r d ej- eak,e rrp vA-4`5 X--o Y-
22
• •
l
151 Windy l till lane
\\�_e 11'inchcstcr, Virginia 22602
9
I *Oundcd in 1971
May 1, 2001
Frederick County Department of Planning and Development
107 North Kent Street
Winchester, VA 22601
ATT: Jeremy Camp
RE: Moxon Timbers - 121 Development Lane (P.1.N. 63-6-5)
Dear Jcremv:
We have prepared this letter to respond to your continents dated March 16, 2001.
We have received confirmation from VDOT that the screening can be installed in the Route 37
right-of-way. Please see the attached letter.
We have corrected the rear setback. The 60' right-of-way to the cast stops at the edge of the
property.
3. The typographic error in the Landscaped Area was corrected.
d. The height of all structures was added to the cover sliect.
5. The total number of employees was added to the cover sheet. This number will not change
following construction of improvements.
6. The total floor area is the same as ground floor area on this site. All buildings are one-story.
7. The use of the existing buildings was labeled.
8. The fire hydrant was added to the plans. We have received approval from the Fire Marshal.
9. The speed limit for Industrial Drive was added to the plans.
10. We have shown an additional loading space.
11. Landscaping calculations do not use the total disturbed area. The total amount of "green" space
after development was calculated from the plans. This number was divided by the total lot area to
calculate the percent of landscaping.
Agency comments arc attached for your use. We look forward to your response to this submittal.
Please contact nlc with any questions or comments.
Sincerely,
Greenway Engineering
Jason J. Thomas, P.E.
Enclosures
CC: Shayne Lachlan - Moxon Timbers
File #]05S/TI-t/dls Lnginccrs Sorvcyois
'telephone 5,10-662-418 i FAX 5,10-722-9525
I
COUNT`' of FBA, DERICK
Department of Planning and Development
540/665-5651
FAX: 540/ 665-6395
March 16, 2001
Mr. Jason J. Thomas, P.E.
Greenway Engineering
151 Windy Hill Lane
Winchester, VA 22602
RE: Review Comments for Site Development Plan 410-01, Moxon Timbers
Property Identification Number 63-6-5
Dear Jason:
Thank you for your recent submission of the above -referenced site plan. A few changes are required
before final site plan approval can be considered. The following comments should correlate with the
red markings on the enclosed copy of the site plan. Please address each of these continents in a
revised site plan.
1. According to Section 165-33, all outdoor storage areas are required to be screened from view
of roads. As you are aware from our previous conversations, a double row of evergreens is
required along the entire rear property line and approximately 300 feet along the right
property line, beginning from the rear. The owners may need to decrease the proposed length
of the gravel storage area to avoid the power line easement.
2. Please correct the rear setback to provide a minimum setback of 75 feet. Furthermore, based
on the site plan provided, it appears that a 60-foot ROW exists along the right boundary line.
If this is a correct assumption, please correct the right setback to indicate a 75-foot setback.
The front setback requirements of the Frederick County Zoning Ordinance apply to all
boundary lines that abut a road. The subject lot appears to have three sides that abut a road.
If a recorded plat shows different setbacks, please provide staff with a copy.
3. Please correct the typographic error on page one of the site plan. Under the Landscaped Area
Calculations, you used decimals instead of commas for the total square feet.
�. Please provide the height of all structures (this includes the three kilns).
,/5. Please state on the site plan how the proposed development will affect the total number of
employees on the site by providing the total number of current employees and the total
number of proposed employees after Phase III. If needed, please correct the parking
calculations to address this concern.
107 North Kent Street o Whiclaester, Virginia 22601-5000
•
Site Plan Review Letter
Moxon Timbers Site Plan #10-01
Page 2
March 16, 2001
,,F: Please distinguish between Total Floor Area and Ground Floor Area in the F.A.R.
calculations on page one of the site plan.
—7. Please label the use of the two existing buildings more specifically. For example, if one
building is used for the packaging of lumber and the other is used for milling, please state this
on the site plan.
1-8. Please provide the location and nature of all fire lanes, fire hydrants, and all other facilities
necessary to meet Fire Code requirements.
-9. Please provide the speed limit for Industrial Drive.
10. Based on your calculation of the total building square feet on the lot, two loading spaces
(� would be required. Please add at least one loading space in order to meet the minimum
requirement. If needed, the additional loading space could be included in one of the later
phases. However, once the square footage exceeds 40,000 square feet, an additional loading
space is required.
11. It appears to staff that your landscaping calculations are incorrect. If you subtract the total
disturbed area (above) from the total lot area, you come up with 107,728 s.f which calculates
to a total landscaped area of 40 percent. Please correct as necessary.
After you have revised the site plan, please resubmit one copy so that I may verify the information
contained on the plan. I will need all approved review agency comment sheets and at least five copies
of the final plan for approval. Comment sheets are required from the following agencies: Frederick
County Inspections Department, Frederick County Engineering/Public Works, Frederick County Fire
Marshal, the City of Winchester, and the Virginia Department of Transportation (VDOT).
Sincerely,
I -<-
Jeremy . Camp
Plamner II
JFC/ch
Enclosure
C NNlyl'ila\Conunon\\Io\onTimbcmSP__Itcv wlal
' 40
Kol
~
SCALE IN FEET
600 0 600 1200 1800 2400
64
62
3 pta
•
i
CITY OF WINCHESTER, VIRGINIA
January 30, 2001
Greenway Engineering
151 Windy Hill Lane
Winchester, VA 22602
Attn.: Jason Thomas, P.E.
Subject: Moxon Timbers
Dear Jason:
We have reviewed the following:
Rouss City Hall
15 North Cameron Street
Winchester, VA 22601
540-667-1815
FAX: 540-722-3618
TDD: 540-722-0782
Web Site:
www.ci.winchestenva.us
Construction Plans for Moxon Timbers, Sheets 1 through 6 of 6, including Sheet 1
(Cover Sheet, dated 12/13/00, latest revision 1/18/01), Sheet 2 (Preliminary Layout,
Phase One, dated 12/13/00, latest revision 1/18/01), Sheet 3 (Preliminary Layout,
Phase Two, dated 12/13/00, latest revision 1/18/01), Sheet 4 (Preliminary Layout,
Phase Three, dated 12/13/00, latest revision 1/18/01), Sheet 5 (Erosion & Sediment
Control, dated 12/13/00, latest revision 1/18/01), Sheet 6 (Details, dated 12/13/00,
latest revision 1/18/01), received January 18, 2001.
Based on our review we have the following comments:
Sanitary
Water
1. No comments.
1. The plans need to clearly define the point of connection (is the proposed
connection point at the location where the existing hydrant connects to the
main?) Note any fittings that may be required.
2. Please include a profile for the proposed main. Plan preparation standards
for the City of Winchester note that the upper half of the drawing shall show
the utility line in plan and the lower half shall show the utility line in profile
along with the existing and proposed final ground surface. Please revise
drawings to conform to this requirement. Stationing shall be shown on the
plan view to match with the profile.
3. Note on the profile that the pipe type is Class 52, cement lined D.I.P.
4. The discharge location for the proposed storm culvert is immediately above
the proposed watermain. We are concerned about the potential for erosion
(and loss of cover). Please revise to eliminate the potential for erosion.
5. The 90-degree bend should be replaced with two 45-degree bends.
"Providing quality services to our citizens iii a cost-effective, efficient and
courteous manner; while anticipating the future needs of our community."
January 30, 2001
Page 2 of 2
6. An easement to the City of Winchester should be shown for the watermain. A
copy of the recorded easement needs to be submitted to the City.
7. A valve should be added at the point where the new main branches off of the
existing main. This would allow the 6-inch main to be shut down.
8. A valve should be shown at the proposed hydrant.
No error or omission in either the plans, calculations or applications (whether these
plans, calculations or applications have been reviewed by the Public Utilities Department
or not) shall permit or release the applicant and designer from constructing this work in
any other manner than that provided for in the Winchester Public Utilities Standards.
If you should have any questions, please do not hesitate to call.
Sincerely,
Dale E. Lehnig, P. E.
Project Engineer — Public Utilities
Enclosures
CC' file
Amy Lohr, Frederick County Planning & Development Dept.
RECEIVE®
1 -1. 0 0
1
2
3
M
5
SITE PLAN APPLICATION
Department of Planning and Development Use only.
Date application received �j ''�'�% . Application #
Complete. Date of acceptance
Incomplete.. Date of return.
Project Title: Moxon Timbers, Inc. Site Plan
Location of Property On the corner of Industrial Drive (Route 880) and Development
(street address) Lane (Route 881), Back Creek District
121 Development Lane, Winchester, VA 22602
Property Owner: Moxon & Company of Delaware, Inc.
Address: same as above
Telephone: (540) 869-5661
Applicant/Agent Greenway Engineering
Address 151 Windy Hill Lane, Winchester, VA 22602
Telephone: (540) 662-4185
Designer: Jason Thomas
Address: same as aqent
Telephone:
Contact:
Jason Thomas
r r'
6a
6b
7a
7b
8
a)
b)
c)
d)
e)
f)
g)
10
Is this a standard or 'minor' site plan?
Is this an original or revised site plan?
Total acreage of parcel to be developed
Total acreage of parcel:
Property Information:
Property Identification Number:
Current Zoning:
Present Use:
Proposed Use:
Standard X
Original
3.7 acres
6.167 acres
Minor
Revised X
New lumber kilns and storage buildings
63-((6))-5
M-1
Lumber processing and storage
Adjoining Property Use(s)
Adjoining Property Identification Number(s)
Magisterial District(s)
same
Vacant or Industrial
63-((6))-1,63-((6))-4,75-((A))-18,
63-((A))-60A
Back Creek
I have read the material included in this package and understand what is required by the
Frederick County Planning Department. I also understand that all required material will be
complete prior to the submission of my site plan.
Signature:
i
Date:
RECEIVED
FFR�77001
DEFT. 4F PLANNl`A0Evti C4 %NT
0
It\ GREENWAY ENGINEERING
%47 151 Windy Hill Lane
Winchester, Virginia 22602
Founded in 1971
TRANSMITTAL,
Project Name: Moxon Timbers
File No.: 1058
Date: February 27, 2001
To: Frederick Co Planning
Attn: Jeremy Camp
Copied:
From: Jason Thomas/ds
GREENWAY ENGINEERING
Phone: 540-662-4185
Fax: 540-722-9528
Ren-karks: 1 Urgent ❑ For YOUr Revicw f-i As You Requested 1-1 Please Comment
Message:
Jeremy,
Attached are the following for the above project:
-2 copies of the site plan
-Application
-Application check
-Frederick County Planning comment sheet
Call with any concert E I V
ED
RE
FFB 27 2001
DEPT. OF PLANNINGIDEVELOPMENT,
I
Engineers Surveyors
Telephone 540-662-4185 FAX 540-722-9528
greenway C[ vlsuallmk.corn
46 0
Request For Site Plan Comments
Department of Planning and Development
Mail to:
Hand deliver to:
Department of Planning and Development
107 N. Kent Street
Attn: County Planner
Fourth Floor
107 North Kent Street
Winchester, VA
Winchester, VA 22601
(540) 665-5651
(540) 665-5651
Please fill out the information as accurately as possible in order to assist the agency with their
review. Please attach two (2) copies of the site plan with this sheet.
Applicant's Name: Greenway Engineering
Address: 151 Windy Hill Lane, Winchester, VA 22601
Phone Number: —(540) 662-4185
Name of development and/or description of the request: Moxon Timbers, Inc. site plan addition
Location of property: Corner of Industrial Drive (Rt 880) and Development Lane (Rt 881)
Planning and Development's Comments:
Planning Dept. use only
Date received
Incomplete
Date reviewed
Signature and Date
Signature and Date (revisi
Date revision received
Date reviewed
Incomplete
Date approved
• •
GREENWAY ENGINEERING
151 Windy Hill Lane
Winchester, Virginia 22602
FoundeJ m !97I
TRANS M ITTAL
Project Name Moxon 'I inihers
File No.: 1058
Date: November 30, 2000
To
Attn
Frederick Co Planning;
Evan Wyatt
Copied: Shane Lachlan — Moxon Timbers
From: Jason Thomas/ds
GREENWAY ENGINEERING
Phone: 540-662-418
Fax: 540-722-9528
Remarks: I— Urgent I- For Your Review I— As You Requested
Message:
Evan,
Attached are the following for the above project for your review:
-Letter rescreening requirements
-Photo
-Proposed site improvements
Call with any concerns.
r Please Comment
RECEIVED
N O V 3 0 2000
DEPT. OF PLANNING/DEVELOPMENT
P� � � K � cT ,
• _ • , A Inv
Engineers Surveyors
Telephone 540-662-4185 FAX 540-722-952;"— "'
greenway@visuallink.com
0 •
I
December 6, 2000
Mr. Jason J. Thomas, P.E.
Greenway Engineering
151 Windy Hill Lane
Winchester, Virginia 22602
RE: Moxon Timbers; 121 Development Lane; P.I.N. 63-6-5
Dear Mr. Thomas:
COUNTY of FREDERICK
Department of Planning and Development
S40/665-5651
FAX 540/665-6395
I have had a chance to review your request regarding Moxon Timbers, received in this office November 30, 2000.
Particularly, you had requested that the County exempt Moxon Timbers from all screening requirements referenced
in §165-33(a) of the Frederick County Code. §165-33(a) states that "... outdoor storage ... shall be completely
screened from the view of road and street rights -of -way and from surrounding properties by a fence, wall, or by
screening." You have indicated that Moxon Timbers' proposed storage areas should be exempt from these screening
requirements because grade deferential make screening impractical.
I am not empowered to waive these screening requirements. However, the Board of Zoning Appeals (BZA) has been
empowered to hear and decide applications for variances from specific terms or requirements of the zoning ordinance.
I have enclosed a copy of the variance application should you wish to pursue such a variance request.
In reviewing the screening requirements for outdoor storage areas, and considering your position that the topography
makes screening impractical for this project, I would offer the following:
1. The ordinance allows for fence, wall or screening to accomplish the intent of screening the outdoor storage;
2. Providing a fence or wall, at a fixed height, may not provide screening as intended;
3. Providing a row of evergreen trees, Leyland Cypress for example, could provide a screen with a height up to 20
feet.
Therefore, it is my position that the screening of outdoor storage is feasible, and I would encourage you to consider
the landscape screening alternative. Please contact me with any questions.
Sincerel
Eric R. Lawrence, AICP, Zoning Administrator
ERL/kac
Enclosure
u:\firic\Common\Dcte minations\hloxonTimbers.Screeming.wpd
107 North Kent Street • Winchester, Virginia 22601-5000
VIEW FROM SHADS.' BUM RD O?J R.T. 37 OVERPASS.
NOTE ROOF OF EX. MOXON BUILDING TO RT.
• •
GROWN ENGINEERING
I,,] �%'indv I Gll I.uir
Winchtwter. Virginia 221,02
Founded in 1971
November 30, 2000
Frederick County Department of Planning and Development
107 North Kent Street
Winchester, VA 22601
ATT: Evan Wyatt
RE: Moxon Timbers - 121 Development Lane (P.I.N. 63-6-5) Screening Requirement
Dear Mr. Wyatt
We respectfully request that the proposed site improvements for the above -referenced project be exempted
from all screening requirements referenced in Frederick County Code 165-33(a). A copy of the plan is
attached. The construction of screening to block the visibility of the proposed storage area (Phase 1) and
buildings (Phase 11 and 111) from the adjacent right-of-way is not practical since Route 37 is elevated near
the property. In addition, due to the height of stacked lumber, screening from surrounding properties is not
practical. All adjacent parcels are zoned M l . A copy of the plan and image of the proposed location from
Route 37 are attached.
Please contact me with any questions or comments.
Sincerely,
Greenway Engineering
Jason J. Thomas, .E.
Enclosures
CC: Shayne Lachlan - Moxon Timbers
File k 1058/J
COUNTY of FREDERICK
Department of Planning and Development
540/665-5651
FAX: 540/ 678-0682
December 18, 2000
Mr. Jason J. Thomas, P.E.
Greenway Engineering
151 Windy Hill Lane
Winchester, Virginia 22602
RE: Moxon Timbers Site Plan Submission
Dear Jason:
I am in receipt of the application made by your firm for the above -referenced site. In looking briefly
at the submitted site plan, it is clear that the requirements for outdoor storage outlined in 165-33(a)
of the Frederick County Code have not been satisfied. As you know, a variance application will be
required should the applicant decide to seek a variance of the outdoor storage requirements. I am
returning the two submitted site plans, application, and check in the amount of $1370.00. Prior to
processing this application for site plan review, I will need one of the following: 1) a site plan
addressing the requirements of Section 165-33(a), or 2) a letter explaining your intent to apply for
a variance with the Board of Zoning Appeals.
If you have any questions or if I can be of further assistance, please do not hesitate to contact me.
Sincerely,
Amy M. Lohr
Planner II
Enclosure
File: tl: t4mylCommonMie PlansiLetterslMozon Timbers Leuer.wpd
107 North Kent Street - Winchester, Virginia 22601-5000
6
•
December 6, 2000
Mr. Jason J. Thomas, P.E.
Greenway Engineering
151 Windy Ell Lane
Winchester, Virginia 22602
RE: Moxon Timbers; 121 Development Lane; P.I.N. 63-6-5
Dear Mr. Thomas:
COUNTY of FREDERICK
Department of Planning and Development
S40166S-5651
FAX 540/665-6395 ?
I have had a chance to review your request regarding Moxon Timbers, received in this office November 30, 2000.
Particularly, you had requested that the County exempt Moxon Timbers from all screening requirements referenced
in § 165-33(a) of the Frederick County Code. § 165-33(a) states that "... outdoor storage ... shall be completely
screened from the view of road and street rights -of -way and from surrounding properties by a fence, wall, or by
screening." You have indicated that Moxon Timbers' proposed storage areas should be exempt from these screening
requirements because grade deferential make screening impractical.
I am not empowered to waive these screening requirements. However, the Board of Zoning Appeals (BZA) has been
empowered to hear and decide applications for variances from specific terms or requirements of the zoning ordinance.
I have enclosed a copy of the variance application should you wish to pursue such a variance request.
In reviewing the screening requirements for outdoor storage areas, and considering your position that the topography
makes screening impractical for this project, I would offer the following:
1. The ordinance allows for fence, wall or screening to accomplish the intent of screening the outdoor storage;
2. Providing a fence or wall, at a fixed height, may not provide screening as intended;
3. Providing a row of evergreen trees, Leyland Cypress for example, could provide a screen with a height up to 20
feet.
Therefore, it is my position that the screening of outdoor storage is feasible, and I would encourage you to consider
the landscape screening alternative. Please contact me with any questions.
Sincerel
Eric R. Lawrence, AICP, Zoning Administrator
ERL/kac
Enclosure
U:\Eric\Common\Dct=in,ations\MoxonTimbLrs. Scrominp.wpd
107 North Kent Street • Winchester, Virginia 22601-5000
. h.
1
Founded in 1971
46 •
151 Windy Hill Line
Winchester, Virginia 22602
November 30, 2000
Frederick County Department of Planning and Development
107 North Kent Street
Winchester, VA 22601
ATT: Evan Wyatt
RE: Moxon Timbers - 121 Development Lane (P.I.N. 63-6-5) Screening Requirement
Dear Mr. Wyatt
We respectfully request that the proposed site improvements for the above -referenced project be exempted
from all screening requirements referenced in Frederick County Code 165-33(a). A copy of the plan is
attached. The construction of screening to block the visibility of the proposed storage area (Phase I) and
buildings (Phase II and III) from the adjacent right-of-way is not practical since Route 37 is elevated near
the property. In addition, due to the height of stacked lumber, screening from surrounding properties is not
practical. All adjacent parcels are zoned M1. A copy of the plan and image of the proposed location from
Route 37 are attached.
Please contact me with any questions or comments.
Sincerely,
Greenway Engineering
Jason J. Thomas, E.
Enclosures
CC: Shayne Lachlan - Moxon Timbers
File II1058/JTT/dls
Engineers Surveyors