HomeMy WebLinkAbout32-07 Betco Supreme - Manufacturing Facility - Stonewall - Backfile (2)t
i
i
m
0
r 0101sr"Al- I fig ZIRA
E XSTIN 10' DRAINAGE AND UT@LIT"° E,4,SE L 9C
OWNER / DEVELOPER
BETCO SUPREME, INC.
1515 TYSON DRIVE, WINCHESTER, VA 22604
P.O.C. SANDY HAYDEN (540) 667-4660
(PROJECT SUMMARY
(PROPERTY IDENTIFICATION NO.:
SITE LOCATION:
43-19-37
1515 TYSON DRIVE,
STONEWALL INDUSTRIAL PARK
WINCHESTER, VA 22603
(PROPERTY AREA:
10 ACRES
(CURRENT ZONING:
M-1
(CURRENT USE:
MANUFACTURING
FACILITY
(FAR ALLOWED:
1.00
(FAR EXISTING:
0.07
SETBACKS
REQUIRED
PROPOSED
FRONT
75'
N/A
SIDE
25'
25'
REAR
25'
25'
(PARKING
5'
N/A
BUILDING HEIGHT
60' MAX
24' t
PROPOSED SILO HEIGHT
60' MAX
44'
NO. EMPLOYEES:
25
RETAIL PARKING — (1 /200 SF)
2
TOTAL PARKING REQUIRED
27
EXISTING PARKING PROVIDED
43
(PREVIOUSLY APPROVED PLANS
ORIGINAL SITE PLAN (SP-49-89) FOR TM 43-19-37 APPROVED 19 DECEMBER, 1989.
SUBSEQUENT SITE PLAN (SP-36-04) APPROVED JUNE, 2004.
THE PROPOSED CEMENT STORAGE SILO ADDITION WILL RESULT IN NO INCREASE IN
VEHICLES PER DAY (VPD) OR IN EMPLOYEES AND THEREFORE NO INCREASE IN THE
PARKING REQUIREMENT. NO ADDITION TO THE RETAIL / OFFICE SPACE IS PROPOSED.
NOTES:
1. ALL SIGNS INSTALLED ON THE PROPERTY WILL COMPLY WITH THE REQUIREMENTS OF
THE FREDERICK COUNTY ZONING ORDINANCE.
2. ALL LIGHTING IS TO BE CONTROLLED TO PREVENT OFF SITE GLARE.
3. ALL FIRE LANES TO BE MARKED AND POSTED PER FREDERICK COUNTY FIRE MARSHALL
REQUIREMENTS.
4. ALL UTILITIES TO BE PLACED UNDERGROUND.
5. SIGNS SHALL BE LOCATED 3 FEET FROM THE FACE OF CURB AND 10 FEET FROM
PROPERTY LINES. MAXIMUM SIGN HEIGHT = 25'. MAXIMUM SIGN AREA = 15 S.F.
6. FIRELANE MARKING SHALL BE PROVIDED AT ALL FIRE HYDRANT AND THE F.D.C. THE
STRIPING CURB PAINTING AND SIGNAGE SHALL MEET THE REQUIREMENTS OF THE FIRE
MARSHALL
7. PROPOSED SILO AS BOLD, EXISTING FEATURES AS GREY.
S. NO NEW LIGHTING OR EXTENSION OF PUBLIC WATER AND SEWER ARE PROPOSED.
9. NEW SILO STRUCTURE SHALL COMPLY WITH THE VIRGINIA UNIFORM STATEWIDE BUILDING
CODE AND SECTION 312, USE GROUP U (UTILITY) OF THE INTERNATIONAL BUILDING
CODE / 2000. STRUCTURAL PLANS SUBMITTED FOR PERMIT APPLICATION SHALL BE
SEALED BY A VA LICENSE DESIGN PROFESSIONAL. PLEASE NOTE THE REQUIREMENTS
IN CHAPTER 17 BC FOR SPECIAL INSPECTIONS ON THIS TYPE OF STRUCTURE.
fICINITYAJAP
TOPO ZONE - ZISGS WINCHESTER, IAA
SCALE. I " = 24, 0001_,&0###0*,._
GRAPHIC ,SCALE
40 20 0 40
WNW 80
/7X ".te
lI . Ifihl Ci 'TEL
lU�b. d3��ev
MAPPING REFERENCE:
INFORMATION SHOWN HEREON WAS PREPARED FROM AERIAL PHOTOGRAPHY AND MAPPING
FROM FREDERICK COUNTY GIS, FLOWN IN 1996, AND DEED FOR PAUL D. MULDOWNEY
RECORDED IN DEED BOOK 713 ON PAGE 894. DATED MAY 22, 1989.
WE
Drawn
JMS
Checked
KJK
Approved
Scale:
s
N
TA T!1
N a0
N OI E
W
O
. U
2*
5 Q
•� Z
uYi a
Y
Q
t
a �
o
c � �
U1 W
co �ai
� Z
u4i
Oz
We
ZLU W
- a�
-N
W
W Z a
a- O 0
IW-
O ~W
L!i
I- In V
LIJ .— Z
Q V d"
Lu OVd
s
..., >
y J
OG d
Z H ~
Z
W 0
Q
W V
Lid
J _V
0W W
Vzui
W
�W � LLL
F- ,= I
1/1
x 5- 6:
W
x
U
ca
E
rn
0- a ar-
0
ooUo
m m N
CW.Dwit m
W
Im
01R-"`m
xli.n n
ki
k R
i �yf
t ' f1�!1ICCarZuni4dliistrwtaDate
RE-
Site Plan valid far five (5) years from approval date.
USA: RESIDENTIALIAGRICULTURAL
TM 43—A— 2 _
*Side Plan valid for two (2) years from FCSA approval dote.
OWNER / DEVELOPER
BETCO SUPREME, INC.
1515 TYSON DRIVE, WINCHESTER, VA 22604
P.O.C. SANDY HAYDEN (540) 667-4660
PROJECT SUMMARY
PROPERTY IDENTIFICATION NO.:
SITE LOCATION:
43-19-37
1515 TYSON DRIVE,
STONEWALL INDUSTRIAL PARK
WINCHESTER, VA 22603
PROPERTY AREA:
10 ACRES
CURRENT ZONING:
M-1
CURRENT USE:
MANUFACTURING
FACILITY
FAR ALLOWED:
1.00
FAR EXISTING:
0.07
SETBACKS
REQUIRED
PROPOSED
FRONT
75'
N/A
SIDE
25'
25'
REAR
25'
25'
PARKING
5'
N/A
BUILDING HEIGHT
60' MAX
24' t
PROPOSED SILO HEIGHT
60' MAX
44'
NO. EMPLOYEES:
25
RETAIL PARKING — (1/200 SF)
2
TOTAL PARKING REQUIRED
27
EXISTING PARKING PROVIDED
43
PREVIOUSLY APPROVED PLANS
ORIGINAL SITE PLAN (SP-49-89) FOR TM 43-19-37 APPROVED 19 DECEMBER, 1989.
SUBSEQUENT SITE PLAN (SP-36-04) APPROVED JUNE, 20D4.
THE PROPOSED CEMENT STORAGE SILO ADDITION WILL RESULT IN NO INCREASE IN
VEHICLES PER DAY (VPD) OR IN EMPLOYEES AND THEREFORE NO INCREASE IN THE
PARKING REQUIREMENT. NO ADDITION TO THE RETAIL / OFFICE SPACE IS PROPOSED.
NOTES:
1. ALL SIGNS INSTALLED ON THE PROPERTY WILL COMPLY WITH THE REQUIREMENTS OF
THE FREDERICK COUNTY ZONING ORDINANCE.
2. ALL LIGHTING IS TO BE CONTROLLED TO PREVENT OFF SITE GLARE.
3. ALL FIRE LANES TO BE MARKED AND POSTED PER FREDERICK COUNTY FIRE MARSHALL
REQUIREMENTS.
4. ALL UTILITIES TO BE PLACED UNDERGROUND.
5. SIGNS SHALL BE LOCATED 3 FEET FROM THE FACE OF CURB AND 10 FEET FROM
PROPERTY LINES. MAXIMUM SIGN HEIGHT = 25'. MAXIMUM SIGN AREA = 15 S.F.
6. FIRELANE MARKING SHALL BE PROVIDED AT ALL FIRE HYDRANT AND THE F.D.C. THE
STRIPING CURB PAINTING AND SIGNAGE SHALL MEET THE REQUIREMENTS OF THE FIRE
MARSHALL
7. PROPOSED SILO AS BOLD, EXISTING FEATURES AS GREY.
B. NO NEW LIGHTING OR EXTENSION OF PUBLIC WATER AND SEWER ARE PROPOSED.
9. NEW SILO STRUCTURE SHALL COMPLY WITH THE VIRGINIA UNIFORM STATEWIDE BUILDING
CODE AND SECTION 312, USE GROUP U (UTILITY) OF THE INTERNATIONAL BUILDING
CODE / 2000. STRUCTURAL PLANS SUBMITTED FOR PERMIT APPLICATION SHALL BE
SEALED BY A VA LICENSE DESIGN PROFESSIONAL PLEASE NOTE THE REQUIREMENTS
IN CHAPTER 17 IBC FOR SPECIAL INSPECTIONS ON THIS TYPE OF STRUCTURE.
VICINITYAVP
TOPO ZONE - USGS WINCHESTER, VA
SCALE: I " = 24, 00T __
GRAPHIC SCALE
40 20 0 40
e0
KEVIN J. KNECHTEL
NG. 032960
%
Zs'
I
O
L IeIA
MAPPING REFERENCE:
INFORMATION SHOWN HEREON WAS PREPARED FROM AERIAL PHOTOGRAPHY AND MAPPING
FROM FREDERICK COUNTY GIS, FLOWN IN 1996, AND DEED FOR PAUL D. MULDOWNEY
RECORDED IN DEED BOOK 713 ON PAGE 894, DATED MAY 22, 1989.
nul
Drown
JMS
Checked
KJK
Approved
Scale:
U�
N r
(n
N o
1
0
c
Ul p
LL
WCo
P - W
V
Z W %0
-r— �► N
wN
W�
W Qi>
Z
CL0O
ULJ
Q�w
!!a
i—LV�V
W `— z
C�
,tVQ
1—
>
t,If
.J
w
zuj
-
, z
�MOW
ua
„U 0
W
Od
icL
19
J
=
(,,,i
< —
tA
�1:W
Lu
za
W
�LLI
r-W
�CW
I
00
CA �
1/1