SITE PLAN CHECKLIST
The checklist below indicates all the information ..that needs to be submitted as part of the site plan
application. All required information must.be submitted prior to the final approval of any site plan.
The Department of Planning and Development will review the application to ensure that it is complete.
If any portion is not included or complete, the site plan application will not be accepted and returned
to the applicant(s).
Site Plan Package
1. One set of approved comment sheets are required from the following review
agencies prior to final site plan approval. It is recommended that applicants contact
the Department of Planning and Development to determine which review agencies
are relevant to their site plan application.
O . Vt c\ 1 Virginia Department of Transportation (VDOT)
c
110-1�' q 1 Frederick County Sanitation Authority
Department of Planning and Development
6 �5'�`► t/ Inspections Department
10 - i TA / Frederick County Engineer (Public Works)
Frederick County Fire Marshal
Department of Parks and Recreation
2. One copy of the Site Plan application
3. Five Copies of the Final Site Plan for approval
4. One reproducible copy of the Site Plan (if required)
5. A 35mm slide of the Site Plan (if required)
County Health Department
City of Winchester
Town of Stephens City
Town of Middletown
Airport Authority
Soil & Water Conservation District
-0111110-WWO4
V- 3 ' File opened
Reference Manual updated/number assigned
vl D-base updated
o- 7. 92 File given to Renee' to update Application Action Summary
dQM�
CLOSE OUT FILE:
Approval (or denial) letter mailed to applicant/copy made for file
V/ File stamped "approved", "denied" or "withdrawn"
,/ Reference Manual updated
t/ D-base updated
QD File given to Renee' for final update to Application Action Summary
U: CaroKommon\GENER1C.TRK
Reviscd I IrJ98
t � FILE COPY
COUNTY of FREDERICK
Department of Planning and Development
540/665-5651
FAX: 540/ 678-0682
April 4, 2000
Mr. David Frank
Greenway Engineering
151 Windy Hill Lane
Winchester, Virginia 22602
RE: Approval of Stonewall Industrial Park - Lot 28, Site Development Plan #42-99
Property Identification Number (PIN): 43-19-51
Dear David:
The Frederick County Department of Planning and Development administratively approved the above -
referenced site plan on April 4, 2000. This site plan, for the phased construction of a 157,016- square -
foot warehouse/office facility, meets all County requirements for development within the M1 (Light
Industrial) Zoning District. The warehouse use will comprise 149.526 square feet of the total building
area, while the office use will account for 7,490 square feet. One -hundred -sixty (160) parking spaces have
been provided, including seven (7) handicap accessible spaces. Adequate perimeter and interior
landscaping have also been provided. Finally, in accordance with Section 165-28(D), all loading areas will
be paved.
I have provided you with several copies of the approved site plan. Please forward these approved plans
to the owner and advise the owner to keep an approved copy for their files. Furthermore, the owner
should ensure that an approved copy is maintained on the construction site throughout the development
process. Once site development has been completed, the owner should contact this office to schedule an
on -site inspection.
Please do not hesitate to contact me should you have any questions or need for elaboration regarding this
letter.
Sincerely,
V rr
Amy M. Lohr
Planner I
AML/ch
Enclosure
cc: Sidney A. Reyes, Gainesboro District Supervisor
June Wilmot, Economic Development Commission
Jane Anderson, Real Estate
Joe Wilder, Public Works
!! A-v (,u . Snr Plm�n A% pruvrJ:01M .6ir plluisarp/nowls S�r�rwol! hwI 11. qn wp/
107 North Kent Street - Winchester, Virginia 22601-5000
GREENWAY ENGINEERING
151 Windy Hill Lane
Winchester, Virginia 22602
Foun,W in 071
T R A N S M I T T A L
Project Name: Stonewall Industrial Park — Lots 26, 27, 28
File No.: 2342
Date: March 31, 2000
To: Frederick Co Planning
Attn: Amy Lohr
Copied:
From David Frank/ds
GREENWAY ENGINEERING
Phone: 540-662-4185
Fax: 540-722-9528
Remarks: f— Urgent PF For Your Review W As You Requested f— Please Comment
Message:
Amy,
Attached are 6 copies of the revised site plan for the above project per your comments.
Call with any concerns.
RECE11iC D
MAR a 1 2000
DEP, IFPANiNG O VtLQPMENT
Engineers Surveyors
Telephone 540-662-4185 FAX 540-722-9528
greenway@visualIink.com
0 •
GREENWAY ENGINEERING
151 Windy Hill Lane
Winchester, Virginia 22602
Foundalin 1971
T R A N S M I T T A L
Project Name: Stonewall Industrial Park — Lots 26, 27, 28
File No.: 2342
Date: March 23, 2000
To: Frederick Co Planning
Attn: Amy Lohr
Copied:
From: David Frank/ds
GREENWAY ENGINEERING
Phone: 540-662-4185
Fax: 540-722-9528
Remarks: f Urgent W For Your Review F7 As You Requested r Please Comment
Message:
Amy,
Attached is 1 copy of the revised site plan per your comments.
Call with any concerns.
RECEIVED
MAR 2 4 2000
DEPT.OF PLANNING/DEVELOPMENT
Engineers Surveyors
Telephone 540-662-4185 FAX 540-722-9528
greenway@visualIink.com
COUNTY of FREDERICK
Department of Planning and Development
540/665-5651
FAX: 540/ 678-0682
March 20, 2000
Mr. David Frank
Greenway Engineering
151 Windy IIill Lane
Winchester, Virginia 22602
RE: Stonewall Industrial Park, Site Development Plan #42-99
Dear David:
I have had the opporthmity to review the revised site plan which was submitted to our department on
March 15, 2000. The following comments should be addressed and included in a revision of this site plan.
In accordance with Section 165-28(D) of the Frederick County Zoning Ordinance, please ensure that
access to loading spaces via driveways and aisles meets the requirements for parking lots as specified
by Section 165-27(E)1. Specifically, the gravel loading areas should be paved.
2. Please insure that the figures in the landscape tabulation correspond to the figures in the project
information. Furthermore, please ensure that all calculations are based on the correct acreage of the
parcel (i.e. impervious surface, parking, F.A.R., etc.).
Please provide dimensions and specifications for all disabled parking spaces and ramps.
The parking calculation indicates that the number of spaces provided is 163. However, the site plan
appears to provide only 160 spaces. Please ensure that this discrepancy is corrected. Please ensure
that the number of handicap spaces provided is seven (7).
The minimum width for two-way traffic aisles in parking areas is 22 feet. All parking aisles appear
to meet this requirement with the exception of the south entrance on Sheet 2c. Please ensure that this
aisle width is increased to at least 22 feet.
Given the anticipated change from gravel to paving in the loading areas, please submit a copy of the revised
plan to the Frederick County Engineer for a second review. After you have revised the site plan, please
resubmit one copy so that I may verify the information contained on the plan. If you have any questions or if
any of the numbered items are unclear, do not hesitate to contact me.
Sincerely,
Amy M. Lohr
Planner I
AML/bah U:WinylCommonOte PlanslSlonetivalllnd. Pk2.spr 42-99.ivpd
107 North Kent Street • Winchester, Virginia 22601-5000
• •
GREENWAY ENGINEERING
151 Windy Hill Lane
Winchester, Virginia 22602
Fuun,led in 19%7
TRANS MITTA L.
Project Name
File No.
Date
Stonewall Industrial Park — Lots 26, 27, 28
2342
March 15, 2000
To: Frederick Co Planning
Attn: Amy Lohr
Copied:
From: David Frank/ds
GREENWAY ENGINEERING
Phone: 540-662-4185
Fax: 540-722-9528
Remarks: f Urgent R For Your Review r As You Requested
Message:
Amy,
Attached is 1 copy of the revised site plan for the above project.
Call with any concerns.
f Please Comment
RECEIVED
MAR 1 5 2000
DEPT OF PLANNING/DEVELOPMENT
Engineers Surveyors
Telephone 540-662-4185 FAX 540-722-9528
greenway@visuallink.com
FINAL SUBDIVISION PLAT
OF A PORTION OF THE LAND OF
LENOIR CITY COMPANY OF VIRGINIA
LOT 28 - STONEWALL INDUSTRIAL PARK
GAINESBORO MAGISTERIAL DISTRICT, FREDERICK COUNTY, VIRGINIA
JAN UARY 11, 2000
D
O
O
S/TE o
A 4 O
f° 3 § Nulton
/he
CP
� ? lone
� A •c
to (e
e t
69 e. 86, MCCh V-732
� ee o
Rte. EXIT
o 317 k
a ti
o VICINITY MAP
P\°°e 4 Am°�°
1a00er Ln 1 = 2000'
OWNER'S CERTIFICATE
THE ABOVE AND FOREGOING SUBDIVISION OF A PORTION OF THE LAND OF LENOIR
CITY COMPANY OF VIRGINIA, AS APPEARS ON THE ACCOMPANYING PLATS, IS WITH THE
FREE CONSENT AND IN ACCORDANCE WITH THE DESIRES OF THE UNDERSIGNED OWNERS,
PROPRIETORS AND TRUSTEES, IF ANY.
COMMONWEALTH OF XIRGINIA
6ffY-f COUNTY OF f- (� �I r L , C-L TO WIT:
THE FOREGOING OWNER'S CERTIFICATE WAS ACKNOWLEDGED BEFORE ME THIS lDAY
it_ 9! BY S.
OF i
Alu
NOTARY PUBLIC
MY COMMISSION EXPIRES 1 2 1—
SURVEYOR'S CERTIFICATE
I HEREBY CERTIFY THAT THE LAND CONTAINED IN THIS SUBDIVISION IS A PORTION
OF THE LAND CONVEYED TO LENOIR CITY COMPANY OF VIRGINIA BY DEED DATED
JANUARY 1, 1968 OF RECORD IN THE FREDERICK COUNTY CI CUIT C URT CLERK'S
OFFICE IN DEED BOOK 344 AT PAGE 235.
MARK D. SMITH, L.S.
NOTE: PARENT TAX PARCEL IDENTIFICATION
LENOIR CITY CO. OF VA. 43—((19))-2 ZONE: M-1 USE: VACANT/IND.
APPROVALS:
FREDERICK COUNTY SANITATION AUTHORITY DATE
1
MRGO41A DEPARTMENT OY iTRANSPORTATION DATE
MARK D. SMITH 9
cti� a.L Z 7 OV
No.002009
FREDERICK COUNTY SUBDIVISION ADMINI ATOR ATE
`N/
SaLTR
GREENW ENGINEERING
151 Windy Hill Lane
Engineers Winchester, Virginia 22602
Surveyors Tekphone: (540) 662-4185
FAX.•(540) 722-9528
Founded in 1971 E-►nail• gr+eenway@vL flink.com
F2342 SHEET 1 OF 4
IRS
00 tK
�a0
6� IRSo/
C2 (- L2 1�
D►PN 17 6 �l
�G P ��
T MER►,43 P
.� 1p D0
(-X
°
N 69'03'37" W
?,S, \•ems,
IRS
197.09' TO
SET STONE FOUND
112"
10DRAINAGE & UTILITY ° IRF
EASEMENT HEREBY RESERVED
CID ' ' ' SEE NOTE 4 (SHEET 3).
N I J LOT 28 I `°
NEW TAX PARCEL
43—((19))-51
N $:1 1.9654 ACRES I I W
co
IM
: I 10' DRAINAGE & UTILITY
q EASEMENT HEREBY RESERVED
O \ SEE NOTE 4 (SHEET 3).
ml
�V DOT -SHADED AREA
DENOTES A VARIABLE
WIDTH DRAINAGE
m EASEMENT HEREBY
1 V
DEDICATED TO THE I
COMMONWEAL TH OF
VIRGINIA.
APPROXIMATE LIMITS I
POB " OF STORM WATER
3/4' L9 BASIN COVENANT (I ►u
IRF ° DB 743 PG 1306
1/0
1 D' co
NOTE "OqN 6< I? 0s ,
SEE SHEET 3 FOR ANp l.,{� 10 �9
CURVE DATA AND '�SSOpj �`���(�9
NF M/ �� '0 MJFD P
EASEMENT LINE DATA. Zp > 4/
150 D 150 USE /ti U8 �A�?T,yFRsyiP �.
GRAPHIC SCALE (IN FEET) k
FINAL SUBDIVISION PLAT
OF A PORTION OF THE LAND OF
LENOIR CITY COMPANY OF VIRGINIA
LOT 28 — STONEWALL INDUSTRIAL PARK
GAINESBORO MAGISTERIAL DISTRICT, FREDERICK COUNTY, VIRGINIA
SCALE: 1" = 150' 1 DATE: JANUARY 11, 2000
GREENWAY ENGINEERING
151 Windy Hill Lane
%Z0
Engineers Winchester, Virginia 22602
Surveyors Telephone. (540) 662-4185
FAX.• (540) 722-9528
Founded in 1971 E-mail: greenway@visuallinkcom
IRS
Z
LC)3Q)
r
a�W
Q6 o N
�m
CQ
v
v vv A��4
MARK D. SMITH
No.002009
lea( H
F2342 SHEET 2 OF 4
/'lll?I/r ndTA
CURVE
DELTA
RADIUS
ARC
TANGENT
CHORD
Cl
53'0537"
930.00'
861.79'
464.63'
N 67'02' 17" W 831.29'
C2
72'3B'20 "
50.00'
63.39'
36.75'
N 57' 15'55 " W 59.23'
C3
13'52' 19 "
780, 00'
188.85
94.89'
N 27'5254 " W 188.39'
C4
13'52' 19 "
1 790.00'
191.27'
96.10'
S 27'5254 " E 190.80'
npAIAIArF FA.(�FAMFIVT llNF DATA
LINE
BEARING
DISTANCE
L 1
N 55' 10'56" E
10.00'
L2
S 50'4 1'26" E
19.60'
L3
N 87'46J8" E
164.75'
L4
N 68*45'01 " E
53.66'
L5
S 69'57' 13" E
142.00'
L6
S 67'20'10" E
172.87'
L7
S 63'03'27" E
90.62'
L8
S 60' 13'23" E
161.66'
L9
S 64'43' 14 " E
12 Z 54 '
L 10
N 38'4648" E
521.40'
L 11
S 68'55'03" E
10.50'
(VOTES
1. IRF = IRON REBAR FOUND (SIZE AS NOTED)
IRS = 5/8" IRON REBAR AND CAP SET
BRL = BUILDING RESTRICTION LINE PER ZONING ORDINANCE.
POB = POINT OF BEGINNING OF METES & BOUNDS DESCRIPTION
2. THE BOUNDARY INFORMATION SHOWN HEREON IS BASED ON A CURRENT FIELD
SURVEY BY THIS FIRM.
3. NO TITLE REPORT FURNISHED. EASEMENTS OR ENCUMBRANCES MAY EXIST WHICH ARE
NOT SHOWN.
4. A DRAINAGE AND UTILITY EASEMENT, TEN FEET IN WIDTH, IS HEREBY RESERVED ALONG
AND INTERIOR TO ALL OF THE BOUNDARIES OF LOT 28 AS SHOWN ON SHEET 2.
FINAL SUBDIVISION PLAT
OF A PORTION OF THE LAND OF
LENOIR CITY COMPANY OF VIRGINIA
LOT 28 - STONEWALL INDUSTRIAL PARK
GAINESBORO MAGISTERIAL DISTRICT, FREDERICK COUNTY, VIRGINI�
SCALE: N/A I DATE: JANUARY 11, 2000
/wAf 7w4\, GREENWAY ENGINEERING
151 Windy Hill Lane
Engineers Winchester, Virginia 22602
Surveyors Telephone: (540) 662-4185
FAX (540) 722-9528
Founded in 1971 E-rwih greenway@visuallinkcom
p
Vv-
v
MARK D. SMITH
No.002009
� )I Islul
F2342 SHEET 3 OF 4
METES AND BOUNDS DESCRIPTION
The accompanying plat represents a division survey of a portion of the land conveyed
to Lenoir City Company of Virginia by deed dated .January I, 1968 of record in the office
of the Clerk of the Circuit Court of Frederick County, Virginia in deed book 344 at page
235. The portion of said land herein described is hereafter to be known as Lot 28 —
Stonewall Industrial Park and is situated on the northeast quadrant of the intersection of
McGhee Road (Va. Route 861) and Kentmere Court (Va. Route 869) within the
development known as Stonewall industrial Park in Gainesboro Magisterial District,
Frederick County, Virginia and is more particularly bounded as follows:
LOT 28
Beginning at a 3/4" iron rebar found at a point of curvature in the northern boundary of
McGhee Road (see deed book 842, page 1 126), corner to Lot 29 (see deed book 743,
page 1300); thence with said road boundary
861.79' along the arc of a curve to the left, having a radius of 930.00' and a chord
bearing N 67°02' 17" W for a distance of 831.29' to a %" iron rebar & cap set at a point
of reverse curvature and at the intersection of said road boundary with the northeastern
boundary of Kentmere Court; thence with said second road boundary for the following
two courses:
63.39' along the arc of a curve to the right, having a radius of 50.00' and a chord bearing
N 57015'55" W for a distance of 59.23' to a %" iron rebar & cap set at a point of reverse
curvature; thence
188.85' along the arc of a curve to the left, having a radius of 780.00' and a chord
bearing N 27052'54" W for a distance of 188.39' to a 5/8" iron rebar & cap set in place of
a bent''/z" iron rebar found, corner to Lot 25 (see deed book 751, page 1238); thence with
Lot 25
N 55010' 56" E — 517.25' to a '/z" iron rebar found in a line in Betty G. McKown (said
rebar being located S 69°03'37" E — 197.09' of a set stone found, a corner common to
Lot 25 and said McKown); thence with McKown
S 69003'37" E — 556.36' to a W iron rebar & cap set corner to other land of Lenoir City
Company of Virginia; thence with said other land
S 68055'03" E — 373.70' to a %" iron rebar & cap set corner to Lot 29, thence with
Lot 29
S 38046'48" W — 622.05' to the beginning.
Containing...................................................................
.................................................................... January 11, 2000.
Surveyed
Sheet 4 of 4
11.9654 Acres
P
V -I V
MARK D. SMITH
No.002009
•
COUNTY of FREDFRICK
Department of Planning and Development
107 North Kent Street • Winchester, Virginia 22601-5000
Telephone: 540/665-5651FAX: 540/678-0682
FAX TRANSMISSION
T0: 1��� i tJ f ►��rJ k
COMPANY: 0-y_EEN WAy
FAX#: S AL i�R— 9SR?
Remarks:
per' 4,
Date: 11- 3 - I c
Number of Pages (including cover sheet) oZ.
5 2 can ej 7 � 1'�1,5 f GL-k- �^5 � �Vta.� C/LQ �c�•P�
� U U II
w-� dU--( 6—IS Dicta,hLc&, -. Tke Snctc" c4-fe-0.S
+l-,.e hAy cvt-t aA 00-k y3-/9 - a . 1-i. a-00-P6--A S 0. 0
RZ eca V10, V--QA co-nFr,, e d
h e SR- e 0 h e C Pali
i n ci fly e-
oi) C2 e e� t r e +D b,v e f"e �0. C cL-LP
q �l Q S�l vrS
V
From the desk of: —Ary,A �� K
• •
GREENWAY ENGINEERING
151 Windy Hill Lane
Winchester, Virginia 22602
Foun,W in 1971
T R A N S M I T T A L
Project Name
File No.
Date
STONEWALL INDUSTRIAL PARK, LOTS 26-28
2342
October 27, 1999
To: FREDERICK COUNTY
PLANNING DEPARTMENT
Attn: AMY LOHR
From: DAVID L. FRANK
GREENWAY ENGINEERING
Phone: 540-662-4185
Ak ur / "&q*5 Fax: 540-722-9528
Copied: 3 �fi 5 �oR lcw_ APP ,^/kc—
Remarks: r- Urgent or Your Review r As You Requested f Please Comment
Message:
ATTACHED ARE THE REVISED PLANS, AS WELL AS THE VARIOUS AGENCIES
APPROVALS FOR THIS SITE PLAN. THANK YOU FOR YOUR HELP ON THIS
PROJECT, AND IF YOU HAVE ANY QUESTIONS PLEASE DO NOT HESITATE TO
CALL.
0;� :.A 14,
� RECIVPD
OW, i_ ?. 7 1q99
DEPT. OFPL�A,%,MENT
Engineers Surveyors
Telephone 540-662-4185 FAX 540-722-9528
greenway@visuallink.com
0 0 sp9i -000L/T
Request For Site Plan Comments
Frederick County Fire Marshal
Mail to:
FracericK County Fire Marshal
A:.r: Director of Engineering
1 C7 Ncr{h Kent Street
Winchester. VA 226C1
511C -3ccr35C
Hand deliver to:
107 N. Kent Street
First Fioor
Wirc: ester. VA
Please fiil cut 'he irfcrmaticr as accurateiv as Pcssibe r cr,er :c ass;st *t7e acerc;, N-7— -77
-ewew. Please attach two !2) copies of the site plan with this sheet.
Acciicant's Name: i Aj A-L
ACcress: i. C i�J N D+., s.iI , A
,::�'-cne Numcerr
Name cf ::eveiccment arc/cr cesc-;ct.cr cf :I . -ecuest: 5�+* �yV LL ., 1,A1Lt+.STG, 4,..
-Icr�Cf W 4C V,r `Se s 1 Tc tLJ�►1
I
� 1
_ccaticr ::f .::rccerty &,tTu FAsT ie,2.� L • �- t'!c. �� G �F�;'r,. ?
tA,u 2. r, Ir_--� S
Request For Site Plan Comments
Fire and Rescue Dept use only
Date rec ived "i--t�-� Date revision received Date aggroved
!=mpiete iwomplete
Date reviewedate viewed
Signature and Date
Sign=e and Date
COUNTY OF FREDERICK, VIRGINIA
FIRE MARSHAL'S OFFICE
LAND DEVELOPMENT COMMENTS
Control No. SP99-0043R Date Received 9/28/99 Date Reviewed 9/29/99
Applicant Greenway Engineering Plan Rev. Date:
Address 151 Windy Hill Lane
Winchester, Va. 22602
Project Name Stonewall Industrial Park Lots 26-28 Phone No. 540-662-4185
Type of Application Site Plan Current Zoning M-1
1st Due Fire Co. 13 1st Due Rescue Co. 13 Election District Gainesboro
Tax I.D. No.
RECOMMENDATIONS
Automatic Sprinkler System XX Residential Sprinkler System
Automatic Fire Alarm SystemXX Other : Knox Security System
REQUIREMENTS
Emergency Vehicle Access
Adequate XX Inadequate Not Identified
Fire Lanes Required Yes XX No
Comments : Fire Lane markings at all hydrants and fire department connection.
Curbage not designated as parking shall also be painted.
Roadway/Aisleway Widths Adequate XX Inadequate Not Identified
Special Hazards Noted Yes No XX
Comments : Requirements of Frederick County Chapter 10.
Hydrant Locations Adequate XX Inadequate Not Identified
Siamese Location Adequate XX Inadequate Not Identified
Additional Comments Attached? Yes No XX
Plan Approval Recommended? Yes XX No
Signature Title
•
LJ
Request For Site Plan Comments
Frederick County Engineering Department
Maii to:
Frederick Ccunty Engineering Dept.
Attn: Director or Engineering
1 C7 Ncrt> ; Kent Street
Winc; ;ester, VA 22�G1
(540) 6c-r-43
Hand deliver to:
107 N. Kent Street
Fourth Ficcr
Winc^ester, VA
Please III out the infcri,aticn as acc::rateiy as ressibie in order to assist tl-:e agency •Writ", t"eir
review. Please attach rrvc (1) copies of the site plan with this sheet.
Azciicant' s Name:
Ac:dr es-,.
P�7cne Nl:rr',cer-
1's'1' 1 "-Z - WI 1 5-
Nar--e c7-eveiccmem arc;cr-escr:Nticn of the revues,: 3n.;S Yy.L=-L- I ,Y iput7-44 -4- PAoL
Eno nBGrii g .Jer�iC^r;crt'� �vmmerlJ. Vt7??� eeyfG✓ •r� t/t L' ��J���? Si iG C/a+. G{-t�i
4-: LJ .0 �.+.'/ Q C! !-I -If ;-A 2 M.4Q- -L) a / 04 'C-�.Z Sty' v �' ' i'� !T
r azi re--ri n 5 Dept.. use only
D mviv-v� to1Z�
I Sizra=-- md Daw
SIz--=x.a md DaL- fr; risi
Dom. r-is:-cn ram. 'Zved
inc-OCT4etc.
Dam- ewL-d
J
Dateproved t 0l 7/ irf
•
•
Request For Site Plan Comments
Frederick County Sanitation Authority
Mail to:
Frederick County Sanitaticn Aut~crit;✓
Attn: Engineer Director
P.O. Box 1877
Wind; ester, VA 22604
(540) 868-1 C61
Hand deliver to:
315 Tasker Road
Stephens City, VA
(54C) 368-1 C61
Please flit gut tl"e irfor-riaticr. as acc.-rateiy as pcssltie ;r Crcer c assist -',e agerc,,, .IV'.,
review. Please attach t•No (2) copies of the site plan with this sheet.
Acciicrrt's Name
AC Cress:
P~Cr e Nl.mcer' Co`� Z- Lf l p S _
�f ceveiccr•er; ard;'cr .escr cr, cr .. _c .es, St0QeWdu.. IN�St�tyt ?�-t
t P OL 000 G 0►-;�jCL Uoj
-AZ �z�4b
Lcc ticr cf :r::cer j, tpOUZr-?— Or d orei�-' k�4
j au LT— IN ,to -�
,=r=der'ck ;CCurty Sanitaticr, ALV:-cr;t`✓'s CommertS' j/t /h'
Sanitation Authority use Only
Date re=ived Date-rvision recc"Ncd Dane 3--IXC-,,cd
Date rcriewcd Date;i !'cl�--
Signa=-- and Date
Signature and D= r-evision)
j,&V, J NE
Request For Site Plan Comments
Frederick Countv Inspections Department
Mail to:
Frederick County Inspections Dept.
Attn: Building Official
107 North Kent Street
Winchester, VA 22601
(540) 665-5650
Hand deliver to:
107 N. Kent Street
Fourth Floor
Winchester, VA
(540) 665-5650
Please fill out the information as accurately as possible in order to assist the agency with their
review. Please attach one (1) copy of the site plan with this sheet.
Applicant's Name:
Address:
W,�tu�•.r��
Phone Number: Z -4 IS.57
Name of development and/or description of the request: ST C:W�
b �i 1 C E / v! AC* A- PCij I-,<-- �TT'E_ F I-a.J
L:,caiicn of pr Ipery: �i6i� i�r (A-kJq,� fD r F '? �, µ E- '20 A A. i D
�- i 4- ' g r e,�-4 z/-n n
Inspections Department's Comments:
comments are on the back of this =o=.
(5'b'r�.i-T• No%E
a
wn ,gba�t.4D,A ",�ccEsS �:�GREsS
•
Building shall comply with the Virginia Uniform Statewide Building Code and section
311, use group S (Storage ) of The BCCA National Building Code/1996. Other codes
that apply are CABO A117.1-92 Accessible and Usable Building and Facilities.
HC parking shall have a min. 8'wide + 8' striped van accessible space. Ouestion
the rerement for a ramp at the main entrance with the elevation change. Please
cui
indicate the location of all required egress doors frcm the building.
Request for Site Plan Comments
Virginia Department of Transportation
Mail to:
Virginia Department of Transportation
Attn: Resident Engineer
14031 Old Valley Pike
Edinburg, Virginia 22824
(540) 984-5600
Hand deliver to:
Virginia Department of Transportation
1550 Commerce Street
Winchester, VA
(540) 722-3460
Please fill out the information as accurately as possible in order to assist the Virginia Decarrre--
of Transportation with their review Please attach five (5) copies of the site plan with traffic
generation daia and drainage caicuiations with this sheet.
Aooiicant's Name
Accress:
Phcne Number:
NaMe of deveiooment and/or descripticr of the revues: SrGmE.WALL, Irau5r0-.A t.F&AL
! ocaticr crccerty AM_It try► Sr (,0 "4.L oT iA y W T,F„ �L,►
�CXA_ r T t 9 Q.t � t faJ
nia Department of Transportation's Comments: see attached letter.
VDOT use oniv
I
I
Date received-7 (2 9 9
Incomplete
Date rmiewedr3LC 199
Signature and Date _
I, Signature and Data (revision
Date revision recerved Date approved 4 . G
Incomplete
Date reviewed i O=4
i
COMMONWEALTH of VIRC
TINIA
DEPARTMENT OF TRANSPORTATION
EDINBURG RESIDENCY
14031 Old Valley Pike
Edinburg, VA 22824
CHARLES D. NOTTINGHAM
ACTING COMMISSIONER
Mr. David Frank
c/o Greenway Engineering
151 Windy Hill Lane
Winchester, VA 22602
Dear David:
October 14, 1999
JERRY A. COPP
RESIDENT ENGINEER
Ref: Stonewall Industrial Park
Lots 26, 27, & 28
Route 851 (McGhee Road)
@ Kentmere Court
Frederick County
This is to acknowledge receipt of your revised plans dated 10/11/99 for the referenced
project. The plans appear satisfactory and are approved. Please advise the developer
accordingly.
I offer the following comments:
• A preconstruction conference be held by the engineer and/or developer with the
attendance of the contractor, various County agencies and VDOT prior to initiation of
work.
• Materials used and method of construction shall apply to current observed VDOT Road
& Bridge Specifications applicable during construction of this development.
• Our review and comments are general in nature. Should conditions in the field exist
such that additional measures are warranted, such measures shall be completed to the
satisfaction of the Department prior to inclusion into the Secondary Road System.
• All drainage is to be carried within the right-of-way in ditch lines or gutters along the
street to a pipe or drainage easement.
• The contractor shall notify VDOT when .work is to begin or cease for any undetermined
length of time. VDOT will also require 48 hours notice for inspections.
WE KEEP VIRGINIA MOVING
u
•
• The appropriate land use permits shall be obtained before any work is performed on the
State's right-of-way. The permit is issued by this office and will require a minimum
processing fee, surety bond coverage, and the salary & expenses of a State assigned
Inspector.
• Any entrances constructed from the referenced street(s) shall meet VDOT minimum
standards. This is the developer's responsibility.
• 1 suggest any utilities and/or storm sewer placed within the proposed right-of-way be
backfilled completely with C.R. Type 21-B Stone. This will greatly reduce the possibility
of any pavement settlement.
Should you need additional information, do not hesitate to call.
Sincerely,
Barry J. Sweitzer, Trans. Roadway Engineer
For: Steven A. Melnikoff, Transportation Engineer
BJS/vcz
Attachments
xc: Mr. D. A. Heironimus
Mr. Kris Tierney
• •
ft\ GREENWAY ENGINEERING
151 %4Windy Hill Lane
Winchester, Virginia 22602
Founded in 1971
T R A N S M I T T A L
Project Name:
File No.:
Date:
To:
Attn:
Copied:
Stonewall Industrial Park -Lots 26, 27, 28
2342
October 12, 1999
Frederick Co Planning
I rum David Frank
GREENWAY ENGINEERING
Phone: 540-662-4185
Fax: 540-722-9528
Remarks: f Urgent R For Your Review r As You Requested r Please Comment
Message:
1 set of above site plan
RECEIVED
T 12 1999
Engineers Surveyors
Telephone 540-662-4185 FAX 540-722-9528
greenway@visuallink.com
vz�Cr"SENT
0
Request For Site Plan Comments
Frederick County Engineering Department
Mail to:
Frederick County Engineering Dept.
Attn: Director of Engineering
107 North Kent Street
Winchester, VA 22601
(540) 665-5643
Hand deliver to:
107 N. Kent Street
Fourth Floor
Winchester, VA
(540) 665-5643
Please fill out the information as accurately as possible in order to assist the agency with their
review. Please attach two (2) copies of the site plan with this sheet.
Applicant's Name:
Address:
Phone Number:
411
its) "Z - L+ l 8 5-
Name of development Ind/or description of the request: �aS yt ALjL- I A Put, t-,=a #� �,V_
I C.F_
Engineering Department's Comments: Uno,, eevre,, ,Si �,ola,., CIO,
9l��I199, alb o- c��2 1?2ee01ajK have Ace.v a-,�i/,2�ssz•1
%- �� � -�,��� t� 2 C' C� ,•►� an �.,,� U,�:o,Qo✓u I o-F -��� �S✓b irct s i � �1�..,
18
• •
GREENWAY ENGINEERING
151 Windy Hill Lane
Winchester, Virginia 22602
Fvundal in 19.'1
T R A N S M I T T A L
Project Name: STONEWALL INDUSTRIAL PARK, LOTS 26-28
File No.: 2342
Date: September 28, 1999
To: FREDERICK COUNTY
Attn: AMY LOHR
Copied:
From: DAVID L. FRANK
GREENWAY ENGINEERING
Phone: 540-662-4185
Fax: 540-722-9528
Remarks: r Urgent I/For Your Review r As You Requested r- Please Comment
Message:
Second submission of site plan. Please do not hesitate to call if you have any questions or
comments.
Engineers Surveyors
Telephone 540-662-4185 FAX 540-722-9528
szreenwavnu,visuallink. com
COUNTY of FREDERICX
Department of Planning and Development
S401665-56S1
FAX: S40/678-0682
September 1, 1999
Mr. David Frank
Greenway Engineering
151 Windy Hill Lane
Winchester, Virginia 22602
RE: Lots 26, 27 and 28 of Stonewall Industrial Park, Site Development Plan #42-99
Dear David:
I have had the opportunity to review the above referenced site plan submitted to our department on
July 30, 1999. The following comments should be addressed and included in a revision of this site
plan. The submitted plan is also marked with these comments. Please note the addition to statement
#12 that did not appear on the facsimile you received.
Please provide a space labeled "Approved by the Zoning Administrator" for the approval
signature and date of approval. In addition, provide a note under the approval box reading
"Site plan shall be valid for five years from date of approval."
2. Please provide the use, zoning, and Property Identification Number (PIN) of all adjoining
properties.
3. Please provide survey coordinates for the subject parcel.
4. Please label all of the parking and building setback lines shown on the site plan in
correspondence with the dimensional standards stated in the Project Information table. Such
setback lines must be provided for all applicable setbacks and should be clearly delineated on
the site plan. Note that the parking area in the southeast corner of the subject parcel
encroaches into the 25-foot setback.
Please show the location of all proposed sidewalks and pedestrian ways. If none are
proposed, please provide a statement to that effect on the site plan.
6. Please show the location of all proposed outdoor trash receptacles and provide a detail of the
structure required for their enclosure.
7. Please state the height of the proposed buildings in terms of feet, rather than stories. The
actual planned height of each phase of building must be stated.
107 North Kent Street v Winchester, Virg inia 22601-5000
Stonewall Industrial Park Site Plan Review
Page 2
September 1, 1999
8. Please provide a floor area ratio (FAR) calculation for this project. Please provide a table
specifying the floor area proposed for each phase of development. Such information should
be further broken down by use within each phase. The total floor area for all three phases
should be stated and subsequently used in the FAR calculation.
9. Please provide the name, number, and posted speed limit of all existing streets located
adjacent to the subject parcel. Specifically, the posted speed limit on McGhee Road is 35
mph. Lakeview Circle (no identified route number) and Kentmere Court (Route 869) should
also be identified on the site plan. These streets do not have a posted speed limit. Finally,
please correct the spelling of McGhee Road.
10. Please provide the dimensions of all proposed entrances from the public right-of-way. In
addition, please show the location of all existing entrances on adjoining roads within 200 feet
of the proposed entrances. Please ensure that the proposed entrance located near the middle
of the subject parcel is aligned with the existing entrance to Spahr Metric.
11. Please show the location of all existing and proposed utility lines. Please ensure the
underground placement of all proposed utility lines by providing a statement to that effect on
the site plan.
12. Please provide the location and width of all easements, including access, utility and drainage
easements. An earlier site development plan on file in this office shows a twenty (20) foot
drainage easement across Lot 28. If this easement still exists, it must be properly vacated
prior to development of the site. Alternate means of stormwater management must be
approved by the Frederick County Public Works Department.
13. Please note that one loading space is required for every 40,000 square feet of floor area with
industrial uses. According to the landscape tabulation, warehouse uses will occupy an area
of 154,325 square feet, which would necessitate a total of four loading spaces. Each loading
space should be twelve (12) feet wide, forty-five (45) feet long, and have a vertical clearance
of at least fourteen (14) feet. It is recommended that the front loading area be separated from
the adjacent parking areas. This will ensure adequate separation of car and truck traffic,
creating a more efficient and safe traffic pattern.
14. Please specify the square footage for each proposed use when tabulating the parking
calculation. According to the landscape tabulation, office space will occupy 10,450 square
feet. One parking space per 250 square feet of office square footage yields 42 spaces, not 21
as indicated by the parking calculation. This would increase the required number of parking
spaces to one -hundred and eighty-four (184). Please note that the required number of
handicap parking spaces is six (6), not seven (7) as indicated by the site plan. Please provide
dimensions and specifications for all disabled parking spaces and ramps. Also note that the
required number of parking spaces stated in the landscape tabulation does not correspond to
the number stated in the parking calculation.
,0 0•
0
Stonewall Industrial Park Site Plan Review
Page 3
September 1, 1999
15. Please provide a planting schedule for the landscape plan. The planting legend should include
the following: plant symbol, quantity, common name, botanical name, size at time of planting,
and any other necessary comments. Also note that a three (3) foot evergreen hedge, fence,
wall or berm is required to prevent headlights from shining on pubic right-of-ways and
adjoining properties. Suitable placement of this landscape feature appears on the marked up
plan. Please ensure that the landscape calculations correspond correctly to the adjusted
parking calculations.
16. Please ensure that Numbers 3, 8, 15, 18, 22 and 23 of the General Notes read as intended.
After you have revised the site plan, please resubmit one copy so that I may verify the information
contained on the plan. I will then need all approved review agency comment sheets and five copies
of the final site plan for approval. Comment sheets are required from the following agencies: the
Virginia Department of Transportation, the Frederick County Sanitation Authority, the Frederick
County Inspections Department, the Frederick County Engineer, and the Frederick County Fire
Marshal.
If you have any questions or if any of the numbered items are unclear, do not hesitate to contact me.
Sincerely,
-.A m
It
Amy M. Lohr
Planner I
AML/ch
Enclosure
U:Wny1CommoalSl1e Pla—Wonnvall Ind. Pkspr 41.99.xpd
SITE PLAN CHECKLIST
The checklist below indicates all the information that needs to be submitted as part of the site plan
application. All required information must be submitted prior to the final approval of any site plan.
The Department of Planning and Development will review the application to ensure that it is ccmplete.
If any portion is not included or complete, the site plan application will not be accepted and returned
to the applicant(s).
Site Plan Package
1. One set of approved comment sheets are required from the following review
agencies prior to final site plan approval. It is recommended that applicants contact
the Department of Planning and Development to determine which review agencies
are relevant to their site plan application.
Virginia Department of Transportation (VDOT)
Frederick County Sanitation Authority
Department of Planning and Development
Inspections Department
Frederick County Engineer (Public Works)
Frederick County Fire Marshal
Department of Parks and Recreation
2. One copy of the Site Plan application
3. Five Copies of the Final Site Plan for approval
4. One reproducible copy of the Site Plan (if required)
5. A 35mm slide of the Site Plan (if required)
County Health Department
City of Winchester
Town of Stephens City
Town of Middletown
Airport Authority
Soil & Water Conservaticn District
Request for Street Name
8
Site Plan Information Checklist
The following information must be included on your site plan. If your site plan is incomplete or
is missing information, it will not be reviewed and returned to you for revisions.
Administrative Information
Y N
✓
1.
Name of proposed development.
✓
2.
Name, address, and phone number of owner.
/!�
3.
Name, address, and phone number of developer.
/✓
4.
Name, address, and phone number of designer.
5.
Certificate of surveyor, engineer, or architect.(s
✓
6.
Date plan prepared and date of revisions.
7.
A listing of all conditions placed on the site as a result of a
conditional use permit or conditional zoning approval.
8.
A space labeled "Approved by the Zoning Administrator' for the
approval signature and date of approval _Pled prCV, Jt-
9.
A description of setbacks or conditions placed on the site as a result
of a variance approval. (Reference the variance
application number.)
General Site Information
Y N
L 10. Location map (scale 1:2000)
11. Magisterial Distnct
12. Scale of site plan (not to exceed 1:50)
13. North Arrow
14. Zoning of site
15. Use, zoning, and Property Identification Number_LPINAof all
adjoining properties. This includes properties located across right-
of-ways, streams, and railroad tracks.
16. Surveyed boundaries for all lots and parcels.
M
General Site (con't)
Y N
{ '
17.
Acreage of all lots included in the plan.
18.
The location and dimensions of all required setbacks and yard
areas. 5 ate IDLc4-� 0.5 66OA C--J �rs�tct- -TI%6
11
y .
19.
The location and type of all dwelling units.
20.
Location and description of all recreation facilities.
21.
Location of sidewalks and pedestrian ways.
22.
Location and area of common open space.
C
k
23.
The location, height, and dimensions of all signs.
24.
Location, height, and specifications of outdoor lighting fixtures.
25.
Location and nature of outdoor storage areas.
J�
26.
Location of outdoor trash receptacles and dimensions of structure
(fencing, etc.) required to enclose receptacles.
Building Information
Y N
1
27.
The height of all buildings and structures. I S tO rV. ' J
28.
Location of all buildings, structures and uses.
29.
The proposed use of each building, structure and area.
30.
Ground floor area and total floor area of all buildings with FAR
calculations for commercial and industrial zoning districts.
Roads
Y N
31.
Name and number of existing and planned streets on and adjoining
the site. %ys,-;, - r ./ , ti11ht4 — -/r,
32.
Location of existing and planned streets on and adjoining the site.
33.
Posted speed limit of existing adjacent roads. GJI't OV, 5,10
34.
Location and dimensions of all proposed entrances from public
right-of-ways.
35,
Location of all entrances on adjoining roads within 200 feet of the
proposed or existing entrance. CAe,(_k c-h -.5.1e
36.
Dimensions, boundaries, width, pavement, and construction of
planned roads
!a
•
Utilities
Y N
37. Location of all utilities, including sewer and water lines with the size
of lines, mains, and laterals. -rv/ZA ,
38. Location and width of all easements, including access, utility, and
drainage easements.
39. Location and nature of fire lanes, fire hydrants, and all other
facilities necessary to meet Fire Code requirements.
Parking
Y N�
40. Calculations describing the required number of parking and loading
spaces. -"r
41. Location and dimensions of all parking and loading spaces,
driveways, parking aisles, curbing and other features to be used.
42. Location and dimension of all disabled parking spaces and
ramps.
Natural Features
Y N
43. Existing and finished contour lines.
44. Location of steep slopes, woodlands, flocdplains, wetlands,
sinkholes, and other environmental features. �A/AJ
45. Location of streams and drainage ways.
Landscaping
Y N
46. Landscaping plan describing location and types of plants to be
used.
47. Location of required buffers and screening with cross sections or
profiles.
Erosion and Sediment Control
Y N
48. A stormwater management plan with run off calculations and
location and description of facilities to be used.
49. Soil erosion and sedimentation control plan describing the location
and methods to be used to minimize erosion and sedimentation
during development.
12
��Ha1,
COMMONWEALTH of VIRGINIA
DEPARTMENT OF TRANSPORTATION
DAVID R. GEHR EDINBURG RESIDENCY
COMMISSIONER 14031 OLD VALLEY PIKE
P.O. BOX 278
EDINBURG. VA 22824-0278
Mr. David Frank
C/O Greenway Engineering
151 Windy Hill Lane
Winchester, VA 22602
Dear David:
August 6, 1999
JERRYA. COPP
RESIDENT ENGINEER
TELE(540)984-5600
FAX (540) 984.5607
Ref: Stonewall Industrial Park
Lots 26, 27 & 28
Route 861 (McGhee Rd.) at Kentmere Court
Frederick County
A VDOT review has been completed on the preliminary site plan dated July, 1999 for
the referenced project. Our comments are as follows and as shown in red on the
enclosed plan sheets:
Sheet 1 of 4
1. The county of reference in the General Notes should be Frederick.
2. The designation of building area in the trip generation data block does not appear
coincident to the given dimensions on Plan Sheet 2 of 4. Please confirm the data
and any adjustments of ITE volumes.
Sheet 2 of 4 (see Note #2)
3. The radii of each/all fillet Curves at the proposed entrances should be shown with
radii measured from face of curb unless otherwise noted.
4. The property frontage adjacent to existing Route 861 (McGhee Road) should provide
12' of right turning lane with CG-6 (if posted speed limit is confirmed at 35 MPH or
CG-7 if unposted as shown on plan) between proposed entrances.
5. & 6. The front slope of the proposed ditch is approaching "worry depth". Could the
ratio be constructed as 3 or 4 to 1?
7. A half typicai section should be shown similar to the one shown on the plan sheet in
red. Also note the "Plan View" sketch of a turning taper for demonstration of
installation.
WE KEEP VIRGINIA MOVING
i
. %% • •
Mr. David Frank
Re: Stonewall Industrial Park, Lots #26, 27 & 28
August 6, 1999
Page #2
8. The available sight distance from each entrance entering onto Route 861 should be
provided at the entrances.
Sheet 3 of 4
9. Please note the question mark on culvert end it and address the concern.
Sheet 4 of 4
10. Please provide appropriate VDOT detail sketches for the project examples: CG-6;
CG-11; CG-12 and E.S.I.
When all the above comments have been addressed, please provide VDOT with one set
of revised plans for review. Should you have any questions, feel free to call.
BJS/rf
Enclosures
xc: Mr. Dave Heironimus
Mr. Kris Tierney
Sincerely,
Barry J. Sweitzer
Trans. Roadway Engineer
For: Steven A. Melnikoff
Transportation Engineer
RECEIVE®
AUG 0 9 1999
DEPT. OF PLANNING/DEVELOPMENT
•
1
Ell
August 6, 1999
Mr. David Frank
Greenway Engineering
151 Windy Hill Lane
Winchester, Virginia 22602
COUNTY of F'REDERICK
Department of Public Works
540/ 665-5643
FAX: 540/ 678-0682
RE: Lot 26, 27 and 28 Stonewall Industrial Park - Site Plan Comments
Frederick County, Virginia
Dear Mr. Frank:
Upon review of the subject site plan, we offer the following comments:
1. Place a note on the plan that indicates that issuance of a land disturbance permit
will be required prior to initiating any site grading work.
2. You have indicated that it will be necessary to install a sediment trap in the
northeast corner of the site. Provide details and calculations in accordance with
the Virginia erosion and sediment control handbook standard and specification
3.13 for the sizing of this sediment trap. If more than three (3) acres are
draining to this point, additional sediment traps may be required.
3. Provide details and sizing of the outlet protection in accordance with the
Virginia erosion and sediment control handbook standard and specification 3.18
for the proposed storm sewer culverts.
4. Provide details from the Virginia erosion and sediment control handbook for all
proposed erosion and sediment control measures shown on the plan.
5. During the construction of the building, it will be necessary to place
approximately six (6) to eight (8) foot of fill to achieve a finished floor
elevation of 730.00. It will be necessary to submit Engineered compaction
reports certifying the fill placement to the Building Inspection department at the
time of building permit application.
6. We recommend that all roof drains be properly sized and piped to the drainage ditches
to prevent on -site erosion. Also, the proposed drainage ditches need to be placed in
107 North Kent Street • Winchester, Virginia 22601-5000
Stonewall Industrial Park
Page 2
August 6, 1999
dedicated drainage easements.
Once these comments have been addressed, submit two (2) copies of the site plan for
further review. If you have any questions, do not hesitate to contact me.
JCW/kch
cc: Frederick County Planning Department
file
Sincerely,
1 I Ar
Joe C. Wilder
Engineering Technician
Department of Public Works
RECEIVED
AUG 0 9 1999
DEPT. OF PLANNAG'DEVELOPMENT
1. Project Title:
2. Location of Property
(street address)
4
5
Property Owner:
Address:
Telephone:
ApplicanUAgent
Address
Telephone:
Designer:
Address:
Telephone:
Contact:
SITE PLAN APPLICATION
4/C lI/« 1411, }-
1O• & ie /Gf7
kl1AK41k3r',Ete— VA . ZZGa i
G78 - ///o
6Z - y/s s
G42- ygg�
i4 V r-> FgAgt
6
•
0
6.
7a
7b
8.
a)
b)
c)
d)
e)
0
g)
Is this an original or revised site plan?
Total acreage of parcel to be developed:
Total acreage of parcel:
Property Information:
Property Identification Number:
Current Zoning:
Present Use:
Proposed Use:
Adjoining Property Use(s)
Adjoining Property Identification Number(s)
Magisterial District(s)
Original Revised
/Z► °S AC.,
17-0 ► Ac-
.f4 ♦V
I have read the material included in this package and understand what is required by the
Frederick County Planning Department. I also understand that all required material will be
complete prior to the submission of my site plan.
Signature:
Date: LI
7
•
0
Request For Site Plan Comments
Department of Planning and Development
Mail to: Hand deliver to:
Department of Planning and Development 107 N. Kent Street
Attn: County Planner Fourth Floor
107 North Kent Street Winchester, VA
Winchester, VA 226C1 (540) 665-5651
(540) 665-5651
Please fill out the information as accurately as possible in order to assist the agency with their
review. Please attach two (2) copies of the site plan with this sheet.
Applicant's Name: OlLcru WA
Address is
Phone Number: (5461 "2 - 41 a
Name of development and/or description of the request: �,TftJ%WA t1- 1+youSrO4 4U ( dam
OF %m l W 4 &F-llau 5IE $ I TE r AAA .
Location of property N@-r, rAt r &i .oj 4J` eF- 94,UEe 9Op A -MC,
Planning and Development's Comments:
Planning and Development use only
Date received D= revision received Date approved _
incomplete Incomplete
Date reviewed Date reviewed
Signature and Date
Signature and Date (revision)
RECEIVED
JUL 3 0 1999
DEPT. Or' r,-,,V%:NG,DEVEtuPMENT
• 0
GREENWAY ENGINEERING
151 Windy Hill Lane
Winchester, Virginia 22602
Fvurukd in 19, I
T R A N S M I T T A L
Project Name:
File No.:
Date:
Stonewall Industrial Park -Lots 26, 27, 28
July 26, 1999
To: Frederick Co Planning
Attn:
Copied:
From: David Frank
GREENWAY ENGINEERING
Phone: 540-662-4185
Fax: 540-722-9528
Remarks: r Urgent ( For Your Review r As You Requested
Message.-
2 sets of site plans with attached comments sheet
1 site plan application with attached check
r Please Comment
Engineers Surveyors
Telephone 540-662-4185 FAX 540-722-9528
greenway@vlsuallink.com