Loading...
HomeMy WebLinkAbout85-05 Valley Biomedical - Freezer Expansion - Back Creek - BackfileW CENERAL NOTES VD0T GENERAL NOTES LEGEND VICINITY .SAP a __ _ 1. Methods and materials used in the construction of the improvements herein shall conform to the current V1. All work on this project shall conform to the current editions of and latest revisions to the Virginia SCALE: 1 = 2000 Z County construction standards and specifications and/or current VDOT standards and specifications. Department of Transportation (VDOT) Road and Bridge Specifications and Standards, the Virginia Erosion and EXISTING INTERMEDIATE CONTOUR - - - _ - 33 Sediment Control Regulations, and any other applicable state, federal or local regulations. In case of a - 2. Measures to control erosion and siltation, including detention ponds serving as silt basins during discrepancy or conflict between the Standards or Specifications and Regulations, the: most stringent shall -® w' °`'• ' ' " EXISTING INDEX CONTOUR 330 construction, govern. ,•�-q 1 ' - •, eq / - • '� 4� ° must be provided prior to issuance of the site development permit. The approval of these plans in no way PROPOSED CONTOUR 40 '• „�� , „e' relieves the developer or his agent of the responsibilities contained in the Virginia Erosion and Sediment V2. All construction shall comply with the latest U.S. Department of Labor, Occupational Safety and Health EX E/p -*� ? o �� w" UJ Control Handbook. Administration (OSHA), and Virginia Occupational Safety & Health (VOSH) Rules and Regulations. EXISTING EDGE OF PAVEMENT bz e,A a� N , , PROPOSED EDGE OF PAVEMENT PROP E/P g .. � P 6 Z 3. A permit must be obtained from the Office of the Resident Engineer, Virginia Department of Transportation V3. When working within VDOT right-of-way, all traffic control, whether permanent -or temporary, shall be in - Q`• "' "� �!� P P Y, EX G d G (VDOT) and Frederick County prior to construction in existing State right-of-way. accordance with the current edition of VDOT's Work Area Protection Manual. Furthermore, all traffic control EXISTING CURB AND GUTTER a4 ��€ SITE " "t •! aaa a �% 4. Approval of this plan does not guarantee issuance of an entrance permit by VDOT when such permit is flaggers must be certified in accordance with Section 104.04(c) of the VDOT Road and Bridge Specifications. - s7s t. ' 3 ate" Z PROP Gff G 5� ' � ._ � required under State law. V4 The developer shall be responsible for relocating, at his expense, any and all utilities, including traffic PROPOSED CURB AND GUTTER 7 ��w 4 ,i aya, ", f " e4 „ CD 00 signal poles, junction boxes, controllers, etc., owned by VDOT or private / public utility companies. It is the TRANSITION FROM CG-6 TO CG-6R �'� " �► `� " \ N '" 5. The exact location of all guard rails will be determined by VDOT personnel. A joint inspection will be held sole responsibility of the developer to locate and identify utility facilities or items iLhat may be in conflict �e� -� A �» m �:• � � ' with the Developer, County Representatives, and Representatives of the Virginia Department of Transportation with the proposed osed construction activity. VDOT a roval of these lans does not indemnif the develo� er from EXISTING TELEPHONE LINE ' ' ' �� nt M 0 VDOT to determine if and where guard rail and of awed ditches will be needed. The developer will beresponsibility. P P y' PP P Y P �' �%' (VDOT) g / P P this res onsibilit m Lo �• P y' PROPOSED TELEPHONE LINE T T = - • " - ,- responsible for providing guardrail and paved ditches as determined by this joint inspection. Refer to O / o, Virginia Department of Transportation (VDOT) Guard Rail and Paved Ditch Specifications. V5. Design features relating to field construction, regulations, and control or safety of traffic may be subject EXISTING STORM SEWER EX, 15" RGP '' '' ` ' _ _ �� 0 1 to change as deemed necessary by VDOT. Any additional expense incurred as a result of any field revision , Z x ►n 6. An approved set of plans and all applicable permits must be available at the construction site. Also, a shall be the responsibility of the developer. PROP. 15" RGP 10 n • ,,, ' :' 'l p representative of the developer must be available at all times. PROPOSED STORM SEWER " „ • • •+ '0 • -'R; �; : '" �� ' �'� o o V6. Prior to initiation of work, the contractor shall be responsible for acquiring all necessary VDOT land use >„ , / ...\ i a�od $-. 7. Warning signs, markers, barricades or flagmen should be in accordance with the Manual on Uniform Traffic permits for any work within VDOT right-of-way. EXISTING SANITARY SEWER Control Devices (MUTCD). PROPOSED SANITARY SEWER n a V7. If required by the local VDOT Residency Office, a pre -construction conference shall be arranged and held �T �T E• 8. All unsuitable material shall be removed from the construction limits of the roadway before placing by the engineer and/or developer with the attendance of the contractor, various County agencies, utility EXISTING ELECTRIC SERVICE SHEET INDEX embankment. companies and VDOT prior to initiation of work. PROPOSED ELECTRIC SERVICE P Pv, u, 9. All pavement sections on the approved plans are based on a minimum CBR value of 6. CBR values less V8. The contractor shall notify the local VDOT Residency Office when work is to begin or cease for any o than 6 will require revised pavement section prepared by Greenway Engineering and approved by the owner. undetermined length of time. VDOT requires and shall receive 48 hours advance notice prior to any required EXISTING GAS LINE N ai or requested inspection. a ,� > 10. All roadside ditches at grades of more than 5% shall be paved with cement concrete to the limits indicated PROPOSED GAS LINE G G $" on,,:the plans and as required at the field inspection. V9. The contractor shall be responsible for maintaining adequate access to the project from the adjacent 9 W U2 public roadway via a construction entrance that is constructed and maintained in accordance with Section PROPERTY LINE 11. All springs shall be capped and piped to the nearest storm sewer manholes or curb inlet. The pipe shall 3.02 of the Virginia Erosion and Sediment Control Handbook. Furthermore, access to other properties affected be minimum 6" diameter and conform to VDOT standard SB-1. by this project shall be maintained through construction. The Developer shall have, within the limits of the FLOW LINE ... .... -.- .... ... 1.) COVER SHEET project, an employee certified by the Virginia Department of Conservation and Recreation (VDCR) in Erosion _L__ 2.) SITE PLAN E- FENCELINE * � 12. Construction debris shall be containerized in accordance with the Virginia Litter Control .Act; no less than and Sediment Control who shall inspect erosion and siltation control devices and measures on a continuous � one litter receptacle shall be provided at the construction site. basis for proper installation and operation. Deficiencies shall be promptly rectified, EXISTING POWER POLE Z O 13. The contractor shall provide adequate means of cleaning mud from trucks and/or other equipment prior to V10. Contractor shall ensure adequate drainage is achieved and maintained on the site during and at the end EXISTING TELEPHONE POLE b W V entering public streets, and it is the contractors responsibility to clean streets, allay dust, and to take of construction. whatever measures are necessary to insure that the streets are maintained in a ,clean, mud and dust free EXISTING WATERLINE W/ TEE ' T' ® O Z condition at all times. Vil. All water and sewer lines within existing or proposed VDOT right-of-way shall have a minimum Ta r� a Z thirty-six (36) inches cover and when possible shall be installed under roadway drainage facilities at conflict PROPOSED WATERLINE W/ TEEy y H Z 14. Notification shall be given to the appropriate utility company prior to construction of water and/or sanitary points. sewer lines. Information should also be obtained from the appropriate authority concerning permits, cut EXISTING FIRE HYDRANT W sheets, and connections to existing lines. V12. Any unusual subsurface conditions (e.g., unsuitable soils, springs, sinkholes, voids, caves, etc.) encountered during the course of construction shall be immediately brought to the attention of the engineer and VDOT. EXISTING WATER VALVE W a 15. All sanitary sewers and water mains and appurtenances shall be constructed in accordance with the current Work shall cease in that vicinity until an adequate design can be determined by the engineer and approved A standards and specifications of the Frederick County Sanitation Authority. by VDOT. PROPOSED WATER METER ® W 16. The location of existing utilities shown in these plans are taken from existing records. It shall be the V13. All fill areas, borrow material and undercut areas shall be inspected and approved by a VDOT EXISTING REDUCER 5 contractors responsibility to verify the exact horizontal and vertical location of all existing utilities as needed representative prior to placement and fill. Where CBR testing is required, a VDOT representative shall be PROPOSED REDUCER a prior to construction. The contractor shall inform the engineer of any conflicts arising from his existing present to insure the sample obtained is representative of the location. When soil samples are submitted to utility verification and the proposed construction. private laboratories for testing, the samples shall be clearly identified and labeled as belonging to a project STOP SIGN ° 0 to be accepted by VDOT and that testing shall be performed in accordance with all applicable VDOT standards W HANDICAP RAMP (CG-12) 11-1 17. The developer will be responsible for any damage to the existing streets and utilities which occurs as a and procedures. h LO � result of his construction project within or contiguous to the existing right-of-way. DENOTES LOCATION OF STD VDOT P j g g g Y• D 0 IURIgDICTI ON�, A V14. All roadway fill, base, subgrade material, and backfill in utility/storm sewer trenches shall be compactedU CONSTRUCTION 18. When grading is proposed within easements of utilities, letters of permission from all involved companies in six (6) inch lifts to 95% of theoretical maximum density as determined by AASHTO T-99 Method A, within PARKING INDICATOR must be provided to Frederick County Public Works Department prior to issuance of grading and/or site plus or minus 2% of optimum moisture for the full width of any dedicated street right-of-way. At the INDICATES THE NUMBER OF TYPICAL PARKING SPACES f� development permits. direction of VDOT, density tests shall be performed by a qualified independent agency in accordance with VDOT THESE PLANS ARE IN CONFORMANCE WITH FREDERICK COUNTY STANDARDS AND ORDINANCES. ANY DEVIATION ® OR CHANGE IN THESE PLANS SHALL BE APPROVED BY THE ZONINfG ADMINISTRATOR PRIOR TO CONSTRUCTION T /a� TON 19. The developer will be responsible for the relocation of any utilities which is required as a result of his Road and Bridge Specifications. Certified copies of test reports shall be submitted to VDOT daily, unless TEST PIT LOCATION specified otherwise. PROd ECT INFOR1fYlA Td project. The relocation should be done prior to construction. V15. VDOT Standard CD and UD underdrains shall be installed where indicated on these plans and/or as 20. These plans identify the location of all known gravesites. Gravesites shown on this plan will be protected specified by VDOT. HANDICAP PARKING U MARK D. SMITH in accordance with state law. In the event gravesites are discovered during construction, the owner and PARCEL INFORMATION: ~0 No, 022837 engineer must be notified immediately. V16. The installation of any entrances and mailboxes within any dedicated street right-of-way shall meet VEHICLES PER DAY COUNT 100 VDOT minimum design standards and is the responsibility of the developer. PIN: TM 63-6-2 21. The contractor is to verify field conditions prior to and during construction a d notify Greenway Engineering PROPOSED BUILDING ENTRANCE at (540) 662-4185 immediately of any discrepancies between actual field conditions and the approved plan. V17. Prior to VDOT acceptance of any streets, all required street signage and/or pavement markings shall be SITE AREA: 3.2 ACRES `SIGNAL installed by the developer or, at VDOT's discretion, by VDOT on an account receivablle basis following the 22. Controlled fills shall be compacted to 95% of maximum density as determined by method "A" per standard Manual On Uniform Traffic Control Devices. EXISTING STREET LIGHT DIST. AREA: 0.3 ACRES proctor AASHTO-T99, ASTM-D698, or VTM-1 as applicable. Density shall be certified by a registered professional engineer and results submitted to Frederick County prior to pavement construction. If a V18. The developer shall provide the VDOT Residency Office with a list of all material sources prior to the geotechnical report has been prepared, it should supersede the requirements in this note. start of construction. Copies of all invoices for materials utilized within any dedicated street right-of-way PROPOSED STREET NAME SIGN + ZONING: M-1 LIGHT INDUSTRIAL DISTRICT co must be provided to the local VDOT Residency Office prior to acceptance of the work. Unit and total prices PROPOSED SANITARY LATERAL CLEANOUT 23. Contractors shall notify operators who maintain underground utility lines in the area of proposed excavating may be obscured. CURRENT USE: OFFICE &PROCESSING FACILITYIMM Pr blasting at least two (2) working days, but not more than ten (10) working days, prior to commencement SANITARY MANHOLE IDENTIFIER 12 of excavation or demolition. Names and telephone numbers of the and operators underground utility lines V19. Aggregate base and subbase materials shall be placed on subgrade by means of a mechanical spreader. PROP. USE: FREEZER EXPANSION U in Frederick County appear below. These numbers shall also be used to serve in an emergency condition. Density will be determined using the density control strip in accordance with Section 304 of the VDOT Road and Bridge Specifications and VTM=10. A certified compaction technician shall perform these tests. Certified STORM DRAIN STRUCTURE IDENTIFIER O6 SETBACKS: FRONT: 75' 0 copies of test reports shall be submitted to VDOT daily, unless specified otherwise. In addition to checking REAR: 25 In depths, a VDOT representative shall be notified and given the opportunity to be present during the construction and testing of the density control strip. SIDE: 25' EASEMENT LINE FCSA CONSTRUCTION NOTES V20. Asphalt concrete pavements shall be placed in accordance with Section 315 of the VDOT Road and Bridge 0CENTERLINE BLDG. HEIGHT: 60' Specifications. Density shall be determined using the density control strip as specified in Section 315 and 1. The Authority's Water and Sewer Standards and Specifications are available at www.fcsa-water.com VTM-76. A certified compaction technician shall perform these tests. Certified copies of test reports shall be EXISTING SPOT ELEVATION 12.0 BLDG. AREA: 2,400 S.F. OFFICE AREA cc submitted to VDOT daily, unless specified otherwise. A VDOT representative shall be notified and given the E-i 2. The water and sanitary sewer portion of these plans are valid for two years from date of FCSA approval. opportunity to be present during the construction and testing of the control strip. PROPOSED SPOT ELEVATION 715 3 11,250 S.F. EX. MANUFACTURING AREA a ram•) 3. Water and sewer lines are to be constructed in accordance with these plans and shall meet all Authority V21. In accordance with Section 302.03, the foundations for pipe culverts thirty-six (36) inches and larger EXISTING THE LINE 2,500 S.F. PROPOSED FREEZER EXPANISION requirements. shall be explored below the bottom of the excavation to determine the type and condition of the foundation. 13,750 S.F. MANUFACTURING AREA J ® > The contractor shall report findings of foundation exploration to the engineer and VDOT for approval prior to E-" 4. The contractor shall coordinate with, and arrange for inspection by, the Authority. placing pipe. Foundation designs shall comply with VDOT Road and Bridge Standard PB-1. Where soft, yielding, 0 UERS CERTIFICATE FLOOR AREA RATIO: 0.125 w or otherwise unsuitable foundation is encountered, the foundation design and/or need for foundation 5. When an existing water main is tapped for the installation of a new line: stabilization shall be determined by the engineer and approved by VDOT. The foregoing Site Plan of the land of a) The Authority shall furnish all labor and material. U b) The developer/contractor must: V22. Approval of these plans shall expire three (3) years from the date of the approval letter. VALLEY BIOMEDICAL PRODUCTS AND SERVICES INC. ® H 1. make application and pay deposit is with the free consent and in accordance with the desires W 0 2. mark the tap location. V23. VDOT Standard CG-12 Curb Ramps shall be installed where indicated on these :plans and/or as specified of the undersigned owners, properties and trustees if any. '> W 6. The contractor shall tie-in a new sewer line to an existing manhole by core drilling the manhole. by VDOT. O 0 W W V24. VDOT Standard Guardrail shall be installed where warranted and/or as proposed on these plans in W Q 7. Exact locations of water and sewer services on new lines are to be coordinated with the Authority's Inspector. accordance with VDOT's installation criteria. Final approval of the guardrail layout to be given by VDOT after DATE O W W LL grading is mostly complete. P4 8. The Authority's maintenance department shall furnish and install all water meters through 2" in size. �r APPROVAL It is the developer's/contractor's responsibility to have the meter box assembly installed correctly. FIRLARSHALL �S NOTE �' i:tfi r - a•: Before a permanent meter is installed: a) The meter box, with its frame and cover, must be properly aligned with the coppersetter. b) The frame and cover shall be set to final grade. Fire lane markings and signage: c) The distance between the top of the cover and the coppersetter shall to be between 18 and 21 inches. Y " g�� g Y P An No Parkin si ns and allow ainted curb locations will be installed FREDERICK COUNTY ZONING ADMINISTRATO DATE d) All components of the meter box assembly shall be in proper working order. by field inspection at the direction of the Fire Marshall's Office. *APPROVAL OF THESE PLANS SHALL EXPIRE FIVE (5) C)5 9. For water and sewer services that connect to existing lines: YEARS FROM THE DATE OF PLANNING APPROVAL TRIP GENERA TION DATA Project Name: Project Number: J a) The location of the service lateral is to be coordinated with the Authority's Engineering Assistant. VALLE Y �^7 ,��T���FREEZ"'R EXPANSION b) An Application for Service must be made and fees paid before work will begin. CLASS USE DWELLING UNITS *TRIP RATE TRIP RATE USE VPD Bpl,/j 1 �D/�// 1 4584 c) The Authority shall furnish and install all 5/8", 3/4" and 1" water services. d) For all 1 1/2" and 2" water services, the Authority shall make the tap and bring the piping to the property line. Magisterial District: Date of Plan: (Month, Day, Year) The contractor shall furnish and install the meter vault assembly. The Authority will install the meter. e) The Authority will install all sewer laterals. BACK CREEK MAGISTERIAL DISTRICT 11 09 05 10. Any water service line must have a backflow prevention assembly (double check valve or RPZ, as required). The assembly must meet ASSE standard No. 1015 or 1013. * T N FROM ITE TRIP GENERATIO1 7TH EDITION Owner: Address, Including Zip Code & Telephone No. DATE: 11/02/05 121 INDUSTRIAL DRIVE 11. All fire lines shall have a fire service meter assembly and a backflow prevention assembly (detector UTILITY CONTACTS VALLEY BIOMEDICAL PRODUCTS & SERVICES, INC. WINCHESTER, VA 22602 double check valve or RPZ, as required). The assembly shall meet ASSE standard No. 1048 or 1047. 868-0800 SCALE: N/A Radio read remotes are required. Water/ Frederick County Sanitation Authority Phone: Verizon Sewer: P.O. Box 1877 P.O. Box 17398 Developer: Address, Including Zip Code & Telephone No. Winchester, VA. 22604 Baltimore, MD 21297 SAME SAME DESIGNED BY. BDP (540) 868-1061 (301) 954-6282 .HANDICAPPED PARKING NOTE Power: Allegheny Power Gas: Shenandoah Gas Co. FILE N0. 4584 P.O. Box 1458 P.O. Box 2400 Engineer Certifying Plan: Address, Including Zip Code & Telephone No. Hagerstown, MD 21741 Winchester, VA 22604 151 WINDY HILL LANE SHEET 1 OF 2 Handicapped parking spaces and aisles shall slope 1-800-654-3317 (540) 869-1111 GREENWAY ENGINEERING WINCH[ESTER, VA 22602 no greater than 2% in all directions. Virginia Utility Protection Service 1-800-552-7001 (540) 662-4185 05-89 � t � •I V o •y V ~ � t 1� b � \ I E, 1 RIM=79 23,' INV. IN =790.47 INV. aU . -OS7 1 I V) I ` q. ■r ^• -... III .,•. �� ,� � � RIM `13010 INV. iN21192..4 �i �I r. I t I � Iij I 0 0- I I W �StoP 1 "sO Corp.CO a I 44' 78� it P < Prop. , 4 Prop. 1"0 Mfeter,I Serp. Meter Box Lidl (Coppw, T) I f I �! 12. a0' I II I t *3� I�'ta it IF`e 2. ai a`C:71� PROPOSED PAVED 50'R TURNING LANE (SEE DETAIL SNT. 3)V �..e 167.28 5F OF - R.O.W. DEDICATION i 7JCr�ESrE, REDER/C1( CI #1 fIi94ISSIAl . ` . dlEtfEL�'>l9�iVr Cr°'�i'�JId1V A/A;• 0 I'i - 609 ZONEV..• 9--! i t 41SK O/WaNr t 0.04' CAN. SsEX. 33ER 2,95�153.a0' Saddle _ 4"qy Inv lr�78 0 +/— `—` #IM=787.32 IN J. 5'l`kt Connection (Top of P>jpe)+ iN'v ¢�i7 25' BUILDING SE7BACK �` r t / \� °- Q 4 , eo 19P ; ! i !l C.0 _ iL k u ROMANO MARIO J 4 LEOCADIA 0'�'a �a p ut AW 6'.3'--`ef-2 an a '- ? � �/ril� O' 4/- ` -2 r m o 't PROPOSED UZ OIMEROA4 & 1N 1VS7RAZ CU�'REh�r USA: C�� U ERGIAL 13a. 78' OSF 17 i W 4J Er. FH A ____— STD, CG t 9 00�,o ago a� �' wrc_ p v o �'•. 1 50.0 o d b o { 5.47l v CUT P�° QSEO`-PAVED RV G. 111 6 EN` DANCE o� Q,�;rao _. ...,` \4e 4d -- (S TU'NIN IF DETAL. sip 74.17' 12 _. 1_ (_ .... � ,� " �� fA Ar�Pr3a�:.. oc�Tio;� —�% SIGHT GISTAn10E=�515° SIGHT DrSTF TO INTX. OF RTE. 651 TO INTX. bf �� ✓'" SIGHT DISTANCE= 60' SIGHT DISTANCE-595' c�� RIM ✓� —. - - - 67 TO INTX. OF RTE, 651 TO INTX. OF RTE. 881 INV. �f3UT - - r~ ..- / I Prop. ES-1, End Section 0 Prop. ES-1, End Section �\ Pro ES-- ! / I Inv. In = 792,00 '=' Inv. Out = 78&50 ' ' Inv. In �8Section 4'00 EX. Entrance ~--- ' AVSON I,���S&OWS n`a• t r='W, r75—A-1 i V g 7,76, Py. 1599 VSf COWMEA161,,41 & 1N,01JS;W1AC 111 I DESIGzN B, OF 6. SEC COMPACTED CHANGE E SUEGRADE OF ACTUAI COMPACTED TO 95% DENSITl AT OPTIMUM MOISTURE cONTE VDOT VTM-I METHOD) TYPICAL, PAVEMENT (NOT TO SGALE) k i '04"VS01V !Nd^2•S7;ario'i✓ ` P//,V ' 2CNcD.• �'-i USE.• 1/146XisV' IMPROVEMENT AREA i '04"VS01V !Nd^2•S7;ario'i✓ ` P//,V ' 2CNcD.• �'-i USE.• 1/146XisV' IMPROVEMENT AREA c _I � r� I x & Wci: f e ce Encla:, co CSC i ADJUST F.H. AS NEEDED - f31.aa" TO FINI,I GRADE ` toD 15' ORAINAGE 48 Es E14ENT GQ q J !` 'z�vta>okwn.�-}+^yy��s_wdn "�� ,•-.•uu+-�.o�ra.+rJ.?, ..aL... t�w�w.� )� ea�,u &km ua +,u�.rmavaaxxiw,aaxw� saeaaear. � N r��.+✓-+a .�. _ _ ,.P� id;t,,glA� L.Yi1ww .-w :..yq+.a•Pawa '•Y.y - 'vr..v w...a�a ,!"' eraN,.•ww.aw .. �. J • .•"ti -�-- 44.00'bl`t 2 f i °��.�y OPERA Tip S )E D .- Rik1=770.42 INV, IN-762.68 INV. OUT-76256 Prop. ES-1, I-nd Section Inv. Out = 780.00 1-2A (ASPHALT) -2 (ASPHALT) 4 (STONE BASE) aSED ON CBR VALUE :TION SUBJECT TO ASED ON FINAL TEST - SU5GRADE MATERIALS. SIT SECTION 8"x8"x'/4" STEEL PLATES TO RECEIVE 6" NO. "T" HINGES 6"xfo" CEDAR POSTS W/ STL. COLUMN BASE GRADE CONSTRUCTION OF A SILT FENCE (WITH WIRE SUPPORT) 1. SET POSTS AND EXCAVATE A 4"X*' 2. STAPLE WIRE FENCING TO THE POSTS. TRENCH UPSLOPE ALONG THE LINIE OF POSTS. j�j Ii 1IRI _:�' a 3. ATTACH THE FILTER FABRIC TO TIRE WIRE FENCE AND EXTEND IT INTO THE: TRENCH. 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. FLOW G EXTENSKON OF FABRIC AND WIRE INTO THE TRENCH SOURCE: Adapted from Installation oft Straw and Fabric Filter Barriers for Sediment Control, PLATE. 3.05-1 kmood k ifent PLANTING BALLED -&-B URLAPPED & CONTAINER -GROWN TREES 1 III III GARDEN HOSE AND WIRE 5X DI*. OF PLIANT AT THE SAME DEPTH AS WHEN PREVIOUSLY GROWN (SLIGHTLY HIGHER IN POORLY-DRAJNED SOILS). SPREAD OUfT ROOTS OF BARE -ROOT SPECIMENS. PREPARE WATERING DEPRESSION INSIDE EXCAVATED AREA PLANTING SOIL MIXTURE TREE WRAP AND STRING TIE STAKES MAY HAVE TO 'BE ANGLED TO GARDEN HOSE AVOID DAMAGE DRIVE STAKES TO ROOT BALL AT SAME / TURNBUCKLE ANGLE AS r I UY WIRE �_ JI ANCHOR (LOG, BRICK, ETC.) VARIABLE, EQUAL TO DEPTH OF ROOT BALL: ALLOWS IT TO SIT ON UNDISTURBED GROUND TREES UNDER 20' TREES OVER 20' SOURCE: VA. DEPTARTMENT OF FORESTRY PLATE 3.37-5 I_ANDSCAPING TABULATIOMS: REQUIRED: I TREE FOR EVfERY 2,000 SF OF IMPERVIOUS) AREA. IMPERVIOUS AREA 3,300 SF TREES REQUIRED - 2? TREES PROVIDED - ,2 4" SQ. STL. TUBING - ALL COWERS AND CENTERS TO BE SHOP WELDED W/ (PLATES BEHIND WELD POINTS DUMPSTER G,4T'E DETAIL (NOT TO SGALE) Wo ROUGH SAWN CEDAR PLANKS T3 311x'/4"x9'0" GATE POST BAR LATCH AND BRACKETS Z W W z z LY 0 o � co 00 )~ Qto C\200 U �y x �In W >' lil 0 0) L0 tw a� r v 0 •N Q% 'J1 W C/I w w w z 0 0 W C-) U Z O z z r q a a � 5 a a w w w 5 5 rTH �('340 o MARK D, SMITH y No, 022837 SIGNAL I (b U O H H w 0 Q _ U) Z u P4 � �:) '-� a 0 W S� < U W Un (:) W W U W � J Q DATE: 11/02/05 SCALE: 1" = 30' DESIGNED BY: BDP FILE NO. 4584 SHEET 2 OF 2 05-89 I GENERAL NOTES VDOT GENERAL NOTES LECEND VICINITY MAID 1. Methods and materials used in the construction of the improvements herein shall conform to the current County construction standards and specifications and/or current VDOT standards and specifications. 2. Measures to control erosion and siltation, including detention ponds serving as silt basins during construction, must be provided prior to issuance of the site development permit. The approval of these plans in no way relieves the developer or his agent of the responsibilities contained in the Virginia Erosion and Sediment Control Handbook. 3. A permit must be obtained from the Office of the Resident Engineer, Virginia Department of Transportation P g g P P (VDOT) and Frederick County prior to construction in existing State right-of-way. 4. Approval of this plan does not guarantee issuance of an entrance permit by VDOT when such permit is required under State law. 5. The exact location of all guard rails will be determined b VDOT personnel. "A joint inspection will be held g Y P ] P with the Developer, County Representatives, and Representatives of the Virginia Department of Transportation (VDOT) to determine if and where guard rail and/of paved ditches will be needed. The developer will be responsible for providing guardrail and paved ditches as determined by this joint inspection." Refer to Virginia Department of Transportation (VDOT) Guard Rail and Paved Ditch Specifications. 6. Ana roved set of plans and all applicable permits must be available at the construction site. Also, a PP P PP P representative of the developer must be available at all times. 7. Warning signs, markers, barricades or flagmen should be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD).Lo 8. All unsuitable material shall be removed from the construction limits of the roadway before placing embankment. 9. All pavement sections on the approved plans are based on a minimum CBR value of 6. CBR values less than 6 will require revised pavement section prepared by Greenway Engineering and approved by the owner. 10. All roadside ditches at grades of more than 5% shall be paved with cement concrete to the limits indicated on the plans and as required at the field inspection. Vl. All work on this project shall conform to the current editions of and latest revisions to the Virginia Department of Transportation (VDOT) Road and Bridge Specifications and Standards, the Virginia Erosion and Sediment Control Regulations, and any other applicable state, federal or local regulations. In case of a discrepancy or conflict between the Standards or Specifications and Regulations, the: most stringent shall govern. V2. All construction shall comply with the latest U.S. Department of Labor, Occupational Safety and Health Administration (OSHA), and Virginia Occupational Safety & Health (VOSH) Rules and Regulations. V3. When working within VDOT right-of-way, all traffic control, whether permanent or temporary, shall be in accordance with the current edition of VDOT's Work Area Protection Manual. Furthermore, all traffic control flaggers must be certified in accordance with Section 104.04(c) of the VDOT Road and Bridge Specifications. V4 The developer shall be responsible for relocating, at his expense, any and all utilities, including traffic signal poles, junction boxes, controllers, etc., owned by VDOT or private / public utility companies. It is the sole responsibility of the developer to locate and identify utility facilities or items that may be in conflict with the proposed osed construction activity. VDOT a roval of these lans does not indemnif the develo developer from P P Y PP P Y P this responsibility. V5. Design features relating to field construction, regulations, and control or safety of traffic may be subject to change as deemed necessary by VDOT. Any additional expense incurred as a result of any field revision shall be the responsibility of the developer. P Y P V6. Prior to initiation of work, the contractor shall be responsible for acquiring all necessary VDOT land use permits for any work within VDOT right-of-way. V7. If required by the local VDOT Residency Office, a pre -construction conference shall be arranged and held by the engineer and/or developer with the attendance of the contractor, various County agencies, utility companies and VDOT prior to initiation of work. V8. The contractor shall notify the local VDOT Residency Office when work is to begin or cease for any undetermined length of time. VDOT requires and shall receive 48 hours advance notice prior to any required or requested inspection. V9. The contractor shall be responsible for maintaining adequate access to the project from the adjacent EXISTING INTERMEDIATE CONTOUR '' - 33' `� - EXISTING INDEX CONTOUR -- 330 PROPOSED CONTOUR 40 EX E/P EXISTING EDGE OF PAVEMENT PROPOSED EDGE OF PAVEMENT PROP E/P EX GAG EXISTING CURB AND GUTTER PROP G4G PROPOSED CURB AND GUTTER G649 GG-bR TRANSITION FROM CG-6 TO CG-6R EXISTING TELEPHONE LINE PROPOSED TELEPHONE LINE T T EXISTING STORM SEWER _ EX. 15�� RGP PROP. 15" RGP PROPOSED STORM SEWER EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING ELECTRIC SERVICE PROPOSED ELECTRIC SERVICE P P EXISTING GAS LINE PROPOSED GAS LINE G Gq SCALE: 1" = 2000' Z UJ Z Z p N CO �■ �j la " r 01 co cCoo Lo 40 � '� °D I rn � � ~ D dCQ Ca x LO W � r- 9 >1 W a� r. so40 W E- w ti, �;� .� ap' � r ;:: g� �� �., .°. p�'� sz e A Sl 0 \ , s \ m y �°�` � • � ... '°' . e f; SITE: y ?" 5 ' • • • �'• a� �" •� s. o,, , • ,� .:: ' • aim. e� u . s. y . ,,,p,� ;`'", .,. _. y, \ ��: •.. �► ,� , ; ,� N ': �r i ' " �. �%, ,� , , •° • g°� "" ti" �' O , ? . � ��• � .... . ; 1. � � „ , s = s ,; ,. 10 n • ar �`�; „ ' , �. °'at �+ '0 '� /` ;i.qJ / w SHEET INDEX ? 03 92 0 o " 0 > W Ul public roadway via a construction entrance that is constructed and maintained in accordance with Section PROPERTY LINE 11. All springs shall be capped and piped to the nearest storm sewer manholes or curb inlet. The pipe shall be minimum 6" diameter and conform to VDOT standard SB-1. 12. Construction debris shall be containerized in accordance with the Virginia Litter Control .Act; no less than one litter receptacle shall be provided at the construction site. 13. The contractor shall provide adequate means of cleaning mud from trucks and/or other equipment prior to entering public streets, and it is the contractors responsibility to clean streets, allay dust, and to take whatever measures are necessary to insure that the streets are maintained in a .clean, mud and dust free condition at all times. 14. Notification shall be given to the appropriate utility company prior to construction of water and/or sanitary sewer lines. Information should also be obtained from the appropriate authority concerning permits, cut sheets, and connections to existing lines. 15. All sanitary sewers and water mains and appurtenances shall be constructed in accordance with the current standards and specifications of the Frederick County Sanitation Authority. 16. The location of existing utilities shown in these plans are taken from existing records. It shall be the contractors responsibility to verify the exact horizontal and vertical location of all existing utilities as needed 3.02 of the Virginia Erosion and Sediment Control Handbook. Furthermore, access to other properties affected by this project shall be maintained through construction. The Developer shall have, within the limits of the project, an employee certified by the Virginia Department of Conservation and Recreation (VDCR) in Erosion and Sediment Control who shall inspect erosion and siltation control devices and measures on a continuous basis for proper installation and operation. Deficiencies shall be promptly rectified. V10. Contractor shall ensure adequate drainage is achieved and maintained on the site during and at the end of construction. V11. All water and sewer lines within existing or proposed VDOT right-of-way shall have a minimum thirty-six (36) inches cover and when possible shall be installed under roadway drainage facilities at conflict points. V12. Any unusual subsurface conditions (e.g., unsuitable soils, springs, sinkholes, voids, caves, etc.) encountered during the course of construction shall be immediately brought to the attention of the engineer and VDOT. Work shall cease in that vicinity until an adequate design can be determined by the engineer and approved by VDOT. V13. All fill areas, borrow material and undercut areas shall be inspected and approved by a VDOT representative prior to placement and fill. Where CBR testing is required, a VDOT representative shall be FLOW LINE ....... FENCELINE �--� EXISTING POWER POLE d EXISTING TELEPHONE POLE EXISTING WATERLINE W/ TEE`- ° �' PROPOSED WATERLINE W/ TEE ! T i EXISTING FIRE HYDRANT EXISTING WATER VALVE PROPOSED WATER METER ® EXISTING REDUCER PROPOSED REDUCER 1.) COVER SHEET 2.) SITE PLAN Z 0 r� W R+ E W a U P� a A W w Z W O U O Z Z Z � a w V1 �r A~ prior to construction. The contractor shall inform the engineer of any conflicts arising from his existing utility verification and the proposed construction. 17. The developer will be responsible for any damage to the existing streets and utilities which occurs as a result of his construction project within or contiguous to the existing right-of-way. 18. When grading is proposed within easements of utilities, letters of permission from all involved companies must be provided to Frederick Count Public Works Department prior to issuance of radio and/or site p y P p grading / development permits. 19. The developer will be responsible for the relocation of any utilities which is required as a result of his project. The relocation should be done prior to construction. 20. These plans identify the location of all known gravesites. Gravesites shown on this plan will be protected in accordance with state law. In the event gravesites are discovered during construction, the owner and engineer must be notified immediately. 21. The contractor is to verify field conditions prior to and during construction and notify Greenway Engineering at (540) 662-4185 immediately of any discrepancies between actual field conditions and the approved plan. 22. Controlled fills shall be compacted to 95% of maximum density as determined by method "A" per standard proctor AASHTO-T99, ASTM-D698, or VTM-1 as applicable. Density shall be certified by a registered professional engineer and results submitted to Frederick County prior to pavement construction. If a geotechnical report has been prepared, it should supersede the requirements in this note. present to insure the sample obtained is representative of the location. When soil samples are submitted to private laboratories for testing, the samples shall be clearly identified and labeled as belonging to a project to be accepted b VDOT and that testing shall be performed in accordance with all applicable VDOT standards P Y g P PP and procedures. V14. All roadway fill, base, subgrade material, and backfill in utility/storm sewer trenches shall be compacted in six (6) inch lifts to 95% of theoretical maximum density as determined by AASH170 T-99 Method A, within plus or minus 2% of optimum moisture for the full width of any dedicated street right-of-way. At the direction of VDOT, density tests shall be performed by a qualified independent agency in accordance with VDOT Road and Bridge Specifications. Certified copies of test reports shall be submitted to VDOT daily, unless specified otherwise. V15. VDOT Standard CD and UD underdrains shall be installed where indicated on these plans and/or as specified by VDOT. V16. The installation of an entrances and mailboxes within an dedicated street right-of-way shall meet Y Y �� Y VDOT minimum design standards and is the responsibility of the developer. V17. Prior to VDOT acceptance of any streets, all required street signage and/or pavement markings s?iall be installed by the developer or, at VDOT's discretion, by VDOT on an account receivable basis following the Manual On Uniform Traffic Control Devices. V18. The developer shall provide the VDOT Residency Office with a list of all material sources prior to the start of construction. Copies of all invoices for materials utilized within any dedicated street right-of-way _� STOP SIGN HANDICAP RAMP (CG-12) DENOTES LOCATION OF STD VDOT JURIsp TION�, suAID 0 COE UR& PARMG INDICATOR Al2 INDICATES THE NUMBER OF TYPICAL PARIffNG SPACES TEST PIT LOCATION HANDICAP PARIOG VEHICLES PER DAY COUNT 100 PROPOSED BUILDING ENTRANCE EXISTING STREET LIGHT PROPOSED STREET NAME SIGN -�- W E., � A e7 LO 0 CQ CQ THESE PLANS ARE IN CONFORMANCE WITH FREDERICK COUNTY STANDARDS AND ORDINANCES. ANY DEVIATION OR CHANGE IN THESE PLANS SHALL BE APPROVED BY THE ZONING ADMINISTRATOR PRIOR TO CONSTRUCTION r� MARK D. SMITH No,022837 � O / �W •� 2 Z'. U.J 4, v �l' `S110 L JECT INFORMATION PROT PARCEL INFORMATION: PIN: TM 63-6 2 SITE AREA: 3.2 ACRES DIST. AREA: 0.3 ACRES ZONING: M-1 LIGHT INDUSTRIAL DISTRICT co 23. Contractors shall notify operators who maintain underground utility lines in the area of proposed excavating or blasting at least two (2) working days, but not more than ten (10) working days, prior to commencement of excavation or demolition. Names and telephone numbers of the and operators underground utility lines in Frederick County appear below. These numbers shall also be used to serve in an emergency condition. must be provided to the local VDOT Residency Office prior to acceptance of the work. Unit and total prices may be obscured. V19. Aggregate base and subbase materials shall be placed on subgrade by means of a mechanical spreader. Density will be determined using the density control strip in accordance with Section 304 of the VDOT Road and Bridge Specifications and VTM=10. A certified compaction technician shall perform these tests. Certified copies of test reports shall be submitted to VDOT daily, unless specified otherwise. In addition to checking stone depths, a VDOT representative shall be notified and given the opportunity to be present during the construction and testing of the density control strip. V20. Asphalt concrete pavements shall be placed in accordance with Section 315 of the VDOT Road and Bridge Specifications. Density shall be determined using the density control strip as specified in Section 315 and VTM-76. A certified compaction technician shall perform these tests. Certified copies; of test reports shall be submitted to VDOT daily, unless specified otherwise. A VDOT representative shall be notified and given the opportunity to be present during the construction and testing of the control strip. V21. In accordance with Section 302.03, the foundations for pipe culverts thirty-six (36) inches and larger shall be explored below the bottom of the excavation to determine the type and condition of the foundation. The contractor shall report findings of foundation exploration to the engineer and VDOT for approval prior to placing pipe. Foundation designs shall comply with VDOT Road and Bridge Standard :PB-1. Where soft, yielding, or otherwise unsuitable foundation is encountered, the foundation design and/or need for foundation stabilization shall be determined b the en sneer and a roved b VDOT. Y g PP Y V22. Approval of these plans shall expire three (3) years from the date of the approval letter. V23. VDOT Standard CG-12 Curb Ramps shall be installed where indicated on these :plans and/or as specified by VDOT. V24. VDOT Standard Guardrail shall be installed where warranted and/or as proposedi on these plans in accordance with VDOT's installation criteria. Final approval of the guardrail layout to be given by VDOT after grading is mostly complete. PROPOSED SANITARY LATERAL CLEANOUT SANITARY MANHOLE IDENTIFIER 12 STORM DRAIN STRUCTURE IDENTIFIER 0 EASEMENT LINE CENTERLINE EXISTING SPOT ELEVATION 12.0 PROPOSED SPOT ELEVATION 115 3 EXISTING THE LINE CURRENT USE: OFFICE & PROCESSING FACILITY PROP. USE: FREEZER EXPANSION SETBACKS: FRONT: 75' 25 SIDE: 25' BLDG. HEIGHT: 60' BLDG. AREA: 2,400 S.F. OFFICE AREA 11,250 S.F. EX. MANUFACTURING AREA 2,500 S.F. PROPOSED FREEZER EXPANSION ,750 SFMANUFACTURING AREA 13.. FLOOR AREA RATIO: 0.125 i1t 4� / m��21(AC Lp" � P ��-��•- U In 0U �--� im C > Q Z Q �, ,� > �-c w � ~ � � G A'' x' < H o 00 00 W W > W ® UJ W cc W W Q ® W w �T+ Z.) � � FCSA CONSTRUCTION NOTES 1. The Authority's Water and Sewer Standards and Specifications are available at www.fcsa-water.com 2. The water and sanitary sewer portion of these plans are valid for two years from date of FCSA approval. 3. Water and sewer lines are to be constructed in accordance with these plans and shall meet all Authority P y requirements. 4. The contractor shall coordinate with, and arrange for inspection by, the Authority. 5. When an existing water main is tapped for the installation of a new line: a) The Authority shall furnish all labor and material. b) The developer/contractor must: 1. make application and pay deposit 2. mark the tap location. 6. The contractor shall tie-in a new sewer line to an existing manhole by core drilling the manhole. 7. Exact locations of water and sewer services on new lines are to be coordinated with the Authority's Inspector. 8. The Authority's maintenance department shall furnish and install all water meters through 2„ in size. It is the developer's/contractor's responsibility to have the meter box assembly installed correctly. Before a permanent meter is installed: a) The meter box, with its frame and cover, must be properly aligned with the coppersetter. b) The frame and cover shall be set to final grade. c) The distance between the top of the cover and the coppersetter shall to be between 18 and 21 inches. d) All components of the meter box assembly shall be in proper working order. 0 WNERS CERTIFICA TF The foregoing Site Plan of the land of VALLEY BIOMEDICAL PRODUCTS AND SERVICES, INC. is with the free consent and in accordance with the desires of the undersigned owners, properties and trustees if any. DATE APPRO VAL FIRE MARSHALL S NOTE � FR DERICK COUNTY ZONING ADMINISTRATOR DATE" *APPROVAL OF THESE PLANS SHALL EXPIRE FIVE (5) Fire lane markings and sianage: " Any No Parkingsigns and yellow painted curb locations will be installed by field inspection at the direction of the Fire Marshall's Office. 9. For water and sewer services that connect to existing lines: a) The location of the service lateral is to be coordinated with the Authority's Engineering Assistant. b) An Application for Service must be made and fees paid before work will begin. YEARS FROM THE DATE OF PLANNING APPROVAL TRIP GENERA TIDN DA TA Project Name: r LLE Y BIOMEDR-7 14 FREEZER EXPANSION Project Number: 4584 CLASS USE DWELLING UNITS *TRIP RATE TRIP RATE USE VPD c) The Authority shall furnish and install all 5/8", 3/4" and 1" water services. � J d) For all 1 1/2" and 2" water services, the Authority shall make the tap and bring the piping to the property line. Magisterial District: Date of Plan: (Month, Day, Year) The contractor shall furnish and install the meter vault assembly. The Authority will install the meter. e) The Authority will install all sewer laterals. BACK CREEK MAGISTERIAL DISTRICT 11 09 05 10. Any water service line must have a backflow prevention assembly (double check valve or RPZ, as required). The assembly must meet ASSE standard No. 1015 or 1013. * T N FROM ITE TRIP GENERATIO 7TH EDITION DATE: 11 02 05 Owner: Address, Including Zip Code & Telephone No. g P P 121 INDUJSTRIAL DRIVE UTILITY CONTACTS SCALE: N/A 11. All fire lines shall have a fire service meter assembly and a backflow prevention assembly (detector double check valve or RPZ, as required). The assembly shall meet ASSE standard No. 1048 or 1047. Radio read remotes are required. q VALLEY BIOMEDICAL PRODUCTS & SERVICES, INC. WINCHES'TER, VA 22602 868-08010 Water Frederick Count Sanitation Authority Phone: Verizon / Y Y Sewer: P.O. Box 1877 P.O. Box 17398 Winchester, VA. 22604 Baltimore, MD 21297 (540) 868-1061 (301) 954-6282 Power: Allegheny Power Gas: Shenandoah Gas Co. P.O. Box 1458 P.O. Box 2400 Hagerstown, MD 21741 Winchester, VA 22604 1-800-654-3317 (540) 869-1111 .Virginia Utility Protection Service 1-800-552-7001 Developer: SAME Address, Including Zip Code & Telephone No. SAME DESIGNED BY: BDP HANDICAPPED PARKING NOTE FILE N0. 4584 Engineer Certifying Plan: GREENWAY ENGINEERING 1 Address, Including Zip Code & Telephone No. 151 WINDY HILL LANE WINCHES'TER, VA 22602 1 (540) 662-4185 SHEET 1 OF 2 Handicapped parking spaces and aisles shall slope no greater than 2% in all directions. 1 05-89 i ` ` �` t /JCrJESt 7,'-f,PED�iP/C1f COUNTY INOUVRIA1 ' QE"!�c"lllplfFNT 00900?A116W 1N- 0-4-609 V,9 749,, Ag 648 > > .ZONED-r o ! ` ' i USf- 04CANT I 1 NM=79 23�' Ex. F.H. INV. IN=79 47 158.00' _EX. 330.04' SAN. SE7rER 1& 2.95! RIM=787,32 1 INV. OUl=X90.37 �— _- ___ ___ — _ - = -- = Saddle 4"0 Inv, ir=785.70 +/- 1N'J. IN y!g4.62. Connection (Top of Roe) INb' Qir1T=�780.5�` 2,5' BUILDING SETBACK � SM-2A (ASPHALT) " BM-2 (ASPHALT) " 21-A (STONE BA5E) :N BASED ON CBR VALUE SECTION SUBJECT TO COMPACTED CHANGE BASED ON FINAL TEST 5U5GRADE OF ACTUAL SU5GRADE MATERIALS. COMPACTED TO 135% DEN5ITY AT OPTIMUM MOISTURE CONTENT VDOT VTM-1 METHOD) TYFICAL PAVE" PENT 5ECTION (NOT TO SCALE) < > °I� f 1. (J E,i 9P ILo I� j( w ROMANO MARIO J 4 LEOGADIA �'• (.0 a� J w FIN.6.3-',-2 i — 14 P Fl?0PQSE'9 U. ' C&IMCRGYAI It'✓011SbRIAl o COMMERCIAL > RN1301.1)L TO PS MU i n' Q--- INV. IN�792 -- # 38. Y'_. __..__ -^�' -. --4C- ... ��,.,+•^'p""", � i S% 0 • �--- I + CUT a Q I d �}JF��� �'(\ 34. '�I 3-. �•%�'Y. w-er+r.^a^"'s" 'm"egby-. \ p.� � Transition flan C4 84 P ,04.2C.0 4.,o Inv, Out,=7Si00 - r�LNWU_"', .7 501 81. - 0r4f'18Cr'd I!v'd TS 7j 20' L2' '""!" 20' O „94,4 54. sr+3,`� zat�£0.'1-1 LIGHT r�>n f f c 1- f0, T � o., � '`lf-0i F`? `� . }'Nn� ��a ,Ysydr�l�,1i. � f' ` rl%JL.• i�fl iiA%5�,�" j ! ; P VEMEN7 30.00' s tr ti I> PROP. FREEZER EXP. o ' "AREA 2500 SF ?� `, ii ,r,v - IMPROVEMENT AREA �^J'�r. �`4c �153 �K"t '' Wla. Cn X1'1a 1 r= o 0) LU r t J' t� a ��% or; 4 95 o h ��' PROPOSED MLANUFACTURiNG FACILITY r. - La < (5 11 b 'ONE STORY HGq.: 60' 9' S0 94. -4- In 1 . 7 �_ (� ��; 0 N AREA: 11,250 Sq. Ft. . 14 0 - .1 I' o O n F,F. 795.00 5 0 I ............. rcv SILT FENCE m' y (L V Pa ^ y ( I{�� c�'. f r.'` �yyyt R RAMPED 6, � -�+ �fr H. 111`fE 4 r 4 rx 94.4 . i _ . 4.2 - .... _ .. 1/ j ?T Stop, 1' Corp. `"`- S R 94 r ; / Q 1'0 PS MU 91 � E RRI=Q � rt tN p Z5'R I. �- Prop..'i `'' Water ,n �- �+ •4LIGHT .12,5 R >` Prop, 1% Met Service N „ _ PAVEMENT 43 �`2' fdOC 5 XISTXN(c3 Meter Box & Lid (Coppizr, Type "h") --- _. f C N 95.2 LOA ING 4.5 R CG'=6R DITCH Pr Du�(ip er I (�Iat) SPACE 42 2 & Wd: It ce of h (T BE C3 ro "�� -- r x Enclo:� . I I 5 R o, `� GRAVEL,' DRIVE 9N STRIPE P P. l�pie\ 9o-1 07 95.1 H �,�VY gb ci L�of .Gcta ; uU.Ci cu PAVIrMENT i 90 ,,..' .• cn / �" 78' °t3UILDIr�1G SETBACK' 9 r o GATE TO BE (n 0 �---- 30.96' � i ss.s REPgAIREDCL ` >' '" cc GRAVEL DRIVE g / l i ,',UJUST F.H. AS NEEDED T4 FINI, /r] GRADE rG o'°"°cpp0 43.00' i I 95.i�i;y' `""'.,,.-.--.. ..'{ 'thy C '. —Pi�. 01`4 i � r. •• �r � � a � 15' OfiAI NAGC ti (j151RAiNAGE { C`E ti t ' L42. %°�1i'` EASEMENT G'' C R } �� 25' PARKING SETEiAC?K in F FJZI_Y i +o� CD A J `'w r ti 925i B7.0 try FA MENT ?"4 i 3lrtyg,kl 11a+' .a: ..._— %Y� I:. ! ..._. -^r y Ili 50R R130.0t.7t'f .; �a- 11=' coTransitionc4 C n, �, cv 19 PROPOSED PAVED - _ _ . y, _. f D nv, out=i�ia.SQ ,{� ,.--`' , �� Zrt�: r'�i`�`--4.0.00' !' � ,... .trL�, _7� •9 ��'... , _�� t��y�.•✓ . _.� . TURNING LANE y� 4 ,ri SEE DETAIL°.^''s 94 4 „. ( `r r 7�- � j Gib 00 1s7.z8 SF OF ~-� - R.O.W. DEDICATION ...� _:�, PAV.'3„ 3"",_.__+..•-.�� a ". `"�".` • f nv; n`Y, ENTRA fLE -'-`t�-u•raruei{` r.w . y'P y ..,-.yYa Ex. FH ^ ---� t jo°c` j'o, rcjrj 9 1 '..i Pro _�_ - J v> STD. CGy-f1 N aa•, 4 o- G1 - f t ' 50.0 5.�k�i J ., CUT P QSE1D PAVED � v1 Cl.I 0 r,,i b �n'� � � � - ��? 1 EIJ DANCE °°r J°?°° �� ;�, 4r C . w ° ° o i o�-....-.. -•— �-,. .-.�,.. .....,.� o e-.--..«.•-�.• r v...... �`.....-. TU i`)Ih1(i' tA�l� . � ;,a,�,,.,.. .•.,_ r aJ.,� ..,.,.-"' ••ea,.. �i ....Y...,. •--•---' - ...-,.. � ...-.... ....-R»l-.:- ...,.... ..,�•4•.•,.e..«..- ...,.,. q� KV IYJV~- _ - V! - -s°' w - -- - - - - - - _ _ - _ (S DETAIL SNT,' 3 � 74.17' PN W W 1Y l�l > 41 - �I oaf ) w --> - W ~ �s - yi -- w __,. Q .. .. .... _ Ef><. �2" ��� M APPRox: , acxrlorl.�- 44 00'�-9----- • a��.� � t .. (fi t. R -O—M +„ 1��' SIGHT DISTANCE=�15' �.�) ,� 2� `rr�r` 0,-�ERTl11�jEl SIGHT D(ST iofCE= 4� _ x - �,. t �1" x, � �,..-. TO INTX. OF RTE. 651 TO INTX. 6F' R-EE- ..._.y' '`•• ,, _._ It .GG _ a SAPd. SIGHT DISTANCE= i 60' SIGHT DISTANCE=595' ( = = - �. '- .` .. ` ,- n _ � �_'� RII.i=%$,r3.�7 ` "'"".�.— RW=I'll�.i� TO IN -IX. Or RTE. 651 TO INTX. OF RTE. 881 `�s-x': INV T-=���"y-y M. IN=782:88 — - . - 1{ � _. .. ,�.�;,., K..,,, _.,, INV.0UT=762 55 .,, NZ i e I — _ ^"'—„: h-�•m asnar.:uswiarc.s:nwnsarc:av+»... acracsu arw%.wn. w:mwxapu:a:aw•r;;iv..»a..azc=:.:.w-sa w+«cr ra»vus w s.s. c..as:.:.-,m c:azcrwez...,; ,,,.,..........-.__.:z-Y.,e „ 1 �jProp. ES-1, End Section 0 Prop. ES-1, End Section' \ Pro ES.- j'� 1 p, a Inv. In - 792,00 Inv. Out = 788.50 Inv. In = 7,6 00 Section ° Out l781700 Section ( , --- Ex. Entrance , 9A;YSC.'V 1W SiMOVTS J PIN.- 7 --A-IA ,09 776, Pg. 16'99 USE' CGIP�4>� RC14Z � � 1NDUSiR14Z 30 15 0 30 60 SCALE: I" = 30' 6"x8"x1/4" STEEL PLATES TO RECEIVE 6" NO. "T" HINGES 6"x6" CEDAR P05TS W1 STL. COLUMN BASE GRADE CONSTRUCTION OF A SILT FENCE (WITH iWIRE SUPPORT) 1. SET POSTS AND EXCAVATE A 4'X4" 2. STAPLE WIRE FENCING TO THE POSTS. TRENCH UPSLOPE ALONG THE LINE OF POSTS. FLOW 3. ATTACH THE FILTER FABRIC TO THE WIFRE FENCE AND EXTEND IT INTO THE TREN(CH. 4 4. BACKFILL AND COMPACT THE EXCAVATED SOIL F1:e,.�r_ EXTENSION OF' FABRIC AND WIRE INTO THE TRENCH. SOURCE: Adapted from InstaUation of Straw and Fabric Fflter Barriers forSediment o o , PLATE. 3.05-1 & nog h Iyant PLANTING BALLED-&-BURLAPPED & CONTAINER -GROWN TREES �II II� GARDEN HOSE AND WIRE 5X DIM. OF THE SAME DEPTH AS WHEN Y GROWN (SLIGHTLY HIGHER —DRAINED SOILS). SPREAD i OF BARE —ROOT SPECIMENS. PREPARE WATERING DEPRESSION INSIDE EXCAVATED AREA PLANTING SOIL MIXTURE TREE WRAP AND STRING TIE STAKES MAY HAVE TO BE ANGLED TO GARDEN HOSE AVOID DAMAGE DRIVE STAKES TO ROOT BALL AT SAME TURNBUCKLE ANGLE AS I UY WIRE J--If ANCHOR (LOG, BRICK, ETC.) • VARIABLE, EQUAL TO DEPTH OF ROOT BALL. ALLOWS IT TO SIT ON UNDISTURBED GROUND TREES UNDER 20' • TREES OVER 20' SOURCE: VA. DEPTARTMENT OF FORESTRY PLATE 3.37-5 LANDSCAPING; TABULATIONS: REQUIRED: 1 TREE FOR EVERY 2,000 5F OF IMPERVIOUS AREA. IMPERVIOUS AREA - 3,300 5F TREES REQUIRED - 2 TREES PROVIDED - 2 4" 5661. STL. TUBING - ALL CORNERS AND CENTER: TO BE SHOP WELDED W1 PLATES BEHIND LELD POINTS lx(o ROUGH SAWN CEDAR PLANKS 6'0" 6'0° DUMPSTER GATE DETAIL (NOT TO SCALE) T3 3"xI/4"xg,0" GATE POST BAR LATCH AND 5RACKETS C5 z W W z I. z W a LO CO 00 a(I) co 'on �c° Bon Zr;! > o CV' W�Q) ''t^ W� 0�� a an U a) �� Hw M cn S-iw w 0 a) C, W w W W z W o U 0 U Z z z z O z � Q 5 w a ate. a a 04 W W CO L E,LO Q C'l Lr) C cD TH OF MARK D, SMITH 9 No022837 �S 4` j `SI:L %iO� 0) U OE H H w J o Q � U� IO W �D O z P4 6 U a W N WUj < U� O U. Q W W W DATE: 11/02/05 1 SCALE: 1" = 30' DESIGNED BY: BDP FILE NO. 4584 SHEET 2 OF 2 05-89