Loading...
HomeMy WebLinkAbout48-01 G.E. Lighting, L.L.C. (Hazardous Materials Storage) - Shawnee - BackfileGE Lighting Winchester Lamp Plant 125 Apple Valley Rd. Winchester, Virginia Hazardous Materials Storage Building ISSUED NO. DATE DESCRIPTION 0 08-31-01 FOR OWNER'S USE 1 10-01-01 ISSUED FOR PERMITS ans approved by: ederick County Public Works Departmer., Plan Reviewer /o/lb /o/ Date DEVELOPER: CPM COMMERCIAL PROJECT MANAGEMENT, INC. ffICEIVED 3076-E SHAWNEE DR W I NCHESTER, VA 226POV 1 9 2001 PHONE (540) 662-1903 FAX (5 4 0) 662 -$�'VPLANNINGIDFVEL0PUr' THE CONTRACFOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE OWNERS REPRESEN- TATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. ARCHITECTS ENGINEERS PLANNERS HWH ARCHITECTS ENGINEERS PLANNERS INC. 1001 LAKESIDE AVENUE -SUITE 800 CLEVELAND. OHIO 44114 a SHEET TITLE HAZARDOUS MATERIALS STORAGE BUILDING SITE PLAN ISSUED OCT. 1, 2001 SCALE 1" =100' -0" DRAWN HEIMBURGER CHECKED TACHOVSKY CONTRACT NO. DRAWING NO. Al-189 SD-1 A1189C00 LAG 100101 � GE WINCHESTER LAMP PLANT Kernstown 81 652 11 651 37 Bartonville LnC:ATION PI AN JGALL: 1 = ZUUU -U OVERALL SITE PLAN SCALE: 1" = 100' -0" - MAGESTERIAL DISTRICT: SHAWNEE - ZONING OF SITE: M-1 - PIN # 63A57 METAL DOORS AND FRAMES 1. QUALITY ASSURANCE : ALL WORK TO BE DONE IN ACCORDANCE WITH THE CURRENT, APPLICABLE RECOMMENDATIONS AND STANDARDS OF THE STEEL DOOR INSTITUTE (SDI) AND THE DOOR AND HARDWARE INSTITUTE, WELDING PER AWS STANDARDS. MANUFACTURER AND INSTALLER SHALL HAVE NOT LESS THAN FIVE YEARS CONTINUOUS, SUCCESSFUL EXPERIENCE IN THE TYPE OF WORK SHOWN. FIRE -RATED ASSEMBLIES SHALL BEAR THE UL LABEL. 2. DOORS: PROVIDE TYPES AND PROFILES AS SCHEDULED. - CONSTRUCTION FULLY WELDED, SEAMLESS, 1 3/4" THICK - EXTERIOR DOOR 16 GAGE STEEL, ASTM A-366 ZINC COATED. - INTERIOR DOOR: 18 GAGE STEEL, ASTM A-366. - INTERNAL CONSTRUCTION : MANUFACTURERS STANDARD HONEYCOMB, SOLID MINERAL CORE OR RIGID STEEL REINFORCING WITH SOUND DEADENING AS APPROVED BY ARCHITECT. - HARDWARE REINFORCEMENT : PER PS4-66 STANDARDS. 3. DOOR FRAMES : PROVIDE TYPES AND PROFILES AS SCHEDULED. - CONSTRUCTION: FULLY WELDED, SEAMLESS WITH INTEGRAL TRIM. - EXTERIOR FRAMES: 14 GAGE STEEL ASTM A-366 ZINC COATED. - INTERIOR FRAMES : 16 GAGE STEEL ASTM A-366. - JAMB ANCHORS FOR STUD PARTITIONS : 18 GAGE, 3 PER JAMB FOR FRAMES TO 7'-6", 4 PER JAMB FOR FRAMES LARGER THAN 7'-6". - OTHER FRAME ELEMENTS : PROVIDE RUBBER BUMPERS (3 PER STRIKE JAMB), BASE ANCHORS, SPREADER BAR, HARDWARE REINFORCEMENTS, DUST COVER BOXES, ETC. FOR A COMPLETE ASSEMBLY. 4. FINISH : RUST INHIBITIVE PRIMER BY FABRICATOR. FIELD PAINT WITH 2 FINISH COATS. HARDWARE NOTES QUALITY ASSURANCE : PROVIDE HARDWARE PER DHI, BHMA & ASACH STANDARDS OF QUALITY. HARDWARE PROVIDER TO HAVE NOT LESS THAN 5 YEARS EXPERIENCE IN HARDWARE SUPPLY AND SCHEDULING. GENERAL : PROVIDE ALL HARDWARE WITH FASTENERS AS REQUIRED FOR A COMPLETE AND PROPER INSTALLATION. PROVIDE TYPES AND FINISHES TO MATCH THAT OF ADJACENT EXISTING UNITS, UNLESS OTHERWISE SHOWN. PACKING AND MARKING: ALL HARDWARE SHALL HAVE THE REQUIRED SCREWS, BOLTS AND FASTENINGS NECESSARY FOR PROPER INSTALLATION, WRAPPED IN PAPER IN SAME PACKAGE AS THE HARDWARE, EACH PACKAGE SHALL BE LEGIBLY LABELED, INDICATING THE PORTION OF THE WORK FOR WHICH IT IS INTENDED. KEYING: COORDINATE WITH OWNERS REQUIREMENTS. CONTRACTORS HARDWARE PROVIDER SHALL MEET WITH OWNERS REPRESENTATIVE TO DETERMINE SPECIFIC HARDWARE REQUIREMENTS FOR EACH DOOR AND DEVELOP A HARDWARE SCHEDULE. ALL HARDWARE AT EXTERIOR DOORS SHALL BE NON-FERROUS. PROJECT NORTH T/ CONIC. Bl EL. SEE SITE FIN. GRADE BOTTOM OF FOOTIN TO BE 6' MIN. BELOW FROST DEPT CONC. BASE DETAIL SCALE: 1/2"-=1' -O" 4000 PSI CONC. BROOM FINISH 41 L 8" COMPACTED CRUSHED STONE PACTED SUBGRADE FILL USED TO ATTAIN DESIRED SUBGRADE ELEVATIONS UNDER SLAB SHALL BE CLEAN, FREE OF ORGANIC CONTAMINATION, PLACED IN 8" MAXIMUM LIFTS (LOOSE THICKNESS), AND SHALL BE COMPACTED TO 100% OF STANDARD PROCTOR MAXIMUM DENSITY( ASTM D698) . -EXISTING PARKING LOT NEW DOOR: PROVIDE PAIR OF 3" X 7" X 1 3/4" INSULATED FLUSH HOLLOW METAL DOORS WITH HOLLOW METAL FRAME. ENTIRE ASSEMBLY TO BE 3 HR. FIRE RATED WITH UL LABEL. DOOR HARDWARE TO BE AS FOLLOWS: 6 HINGES - HAGER BB1279 4 1/2" X 4 1/2" WITH NON -REMOVABLE PIN. 1 PANI3 EXIT DEVICE WITH LEVER HANDLE TRIM AT EXTERIOR. FUNCTION TO BE OFFICE ENTRANCE. 1 CLOS7R - LON 4000 SERIES. 1 CYLINDER - TYPE PER OWNER'S EXISTING. 1 PAIR OF SURFACE BOLTS AT INACTIVE LEAF (TOP & BOT) PERIMETER WEATHER SEAL, ASTRAGAL WEATHERSEAL, AND METAL THRESHOLD. METAL THRESHOLD SHALL NOT EXCEED 1/2" HEIGHT. SEE DETAILS BELOW. NOTE: NEW STRIPING & "NO PARKING" SIGNAGE BY OWNER FOR FIRE TRUCK ACCESS TO FIRE HYDRANT N 00 1-9/16" 1-15/16 5 3/4 @ DOOR TYPICAL DOOR FRAME DETAIL NO SCALE SEALANT DOOR J H. M. H. M. FRAME (TYPICAL) SEALANT JAMB DETAIL SCALE: 1 1/2" = 1'-0" EXISTIN( METAL S. FLASHIN( SEALANT H. M. C_ED 3 1/2" 5 3/4" FRAME HEAD DETAIL SCALE: 1 1/2" = 1' -0" 3 JAMB ANCHORS PER JAMB EXIST. MASONRY EXISTING CHANNEL SEALANT HOLLOW METAL DOOR r - - - - -7 70- - - - - - - - - - / EXISTING FIRE HYDRANT - ;---- - - - EXISTING FIRE -772 - - - - - - - - - - - 772. 5 c J c Jl `\ 772. 0 0 \ - - _ - - - _ �1) EXISTING — — — — r - -�- - - - - - _ - - - - - - /`\ I CONTAINMENT - - - - - - - - \ AREA / -773- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - —774- - - - - - - - - - - EXISTING - LIGHT FIXTURE ------- - - - - -- - - - - - - -- SETBACKS AT NEW BUILDING: NOT APPLICABLE IN THAT NEW BUILDING IS WELL WITHIN THE BOUNDARIES OF THE PROPERTY EASEMENTS AT NEW BUILDING: NO APPLICABLE EASEMENTS IN THE AREA OF THE NEW BUILDING EXISTING, --TOP/ CONC. BASE TREE EL. 775. 416' ( SEE DET. A) CONC. SLAB 17' -6" EXISTING i� LIGHT FIXTURE - - - - - 16' -6 - - 6-- -775- - - - - - - - - - ,ram BUILDING c° 19' -7"/ m NEW HAZARDOUS z: - N t- 20' -1" STORAGE BUILDING o cO cD FIN. FLOOR ♦ EL. 776. 0' 00 ♦ m o EL. 776. 0 NEW DOOR SEE NOTES ABOVE NEW RAMP UP (STEEL) —EL. 775. 416' CONTROL JOINTS NEW CONC. SIDEWALK 2 0' X 16' 6' -4'_EXISTING BUILDING NEW FINISH FLOOR M. 0. EL_ 776. 0' PARTIAL SITE PLAN SCALE: 1" = 10' -0" NEW HAZARDOUS STORAGE BUILDING OCCUPANCY: HAZARDOUS GROUP H-2 CONSTRUCTION: PRE MANUFACTURED STEEL UNIT 2 HR. WALLS AND CEILING (SEE MANUFACTURER'S INFORMATION) STORAGE BUILDING: AREA: 140 S. F. HEIGHT: 8'-6" APPROVED BY THE ZONING A MINISTATOR S I G N E D'4 DATE VALID FOR 5 YEARS GE Lighting Winchester Lamp Plant 125 Apple Valley Rd. Winchester, Virginia Hazardous Materials Storage Building ISSUED NO. DATE DESCRIPTION 0 08-31-01 FOR OWNER'S USE 1 10-01-01 ISSUED FOR PERMITS 2 11-14-01 REVISED NAB' SITE PLAN JkPPROVEED �/,At;�v✓) DEVELOPER: CPM COMMERCIAL PROJECT MANAGEMENT, INC. 3076-E SHAWNEE DRIVE WINCHESTER, VA 22601 PHONE (540) 662-1903 FAX (540) 662-8845 THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESEN- TATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA- -][WH ARCHITECTS ENGINEERS PLANNERS HWH ARCHITECTS ENGINEERS PLANNERS INC. 1001 LAKESIDE AVENUE • SUITE 800 CLEVELAND. OHIO 44114 SHEET TITLE HAZARDOUS MATERIALS STORAGE BUILDING SITE PLAN ISSUED OCT_ 1, 2001 SCALE 1" =100' -0" DRAWN HEIMBURGER CHECKED TACHOVSKY CONTRACT NO. DRAWING NO. Al-189 SD-1 A1189COO HAT 111401 _T GE Lighting Winchester Lamp Plant 125 Apple Valley Rd. Winchester, Virginia Hazardous Materials Storage Building ISSUED DATE DESCRIPTION r02 08-31-01 FOR OWNER'S USE 10-01-01 ISSUED FOR PERMITS 11-14-01 REVISED APPROVED �/ui,vUr� A1189C00 HAT 111401