Loading...
HomeMy WebLinkAbout36-03 HP Hood Wastewater Trmt. - Treatment Plan Expansion - Shawnee - Backfile (2)SITE PLAN TRACKING SHEET Date: Z7 C23 File opened 9'/X7/0Reference Manual updated/number assigned 1� 03 D-base updated 8.k?. 03 File given to Renee' to update Application Action Summary akk_- CLOSE OUT FILE: 4n8 Approval (or denial) letter mailed to applicant/copy made for file - 0,/ IhA—c File stamped "approved", "denied" or 'Withdrawn" % 3Reference Manual updated / i � D-base updated A/CC %1•�3.43 File given to Renee' for final update to Application Action Summary . Cwoi,Com.c Jlalk�nS shcaUJnc Plan T—kmg wPd Kmc d 0J07'01 SITE PLAN APPLICATION CHECKLIST The checklist shown below specifies the information which is required to be submitted as part of the site plan application. The Department of Planning & Development will review the application to ensure that it is complete prior to accepting it. If any portion of the application is not complete, it will be returned to the applicant(s). (1) One (1) set of approved comment sheets are required from each relevant review agency prior to final approval of a site plan. It is recommended that applicants contact the Department of Planning & Development to determine which review agencies are relevant to their site plan application. A list of potentially relevant review agencies is shown below: ✓ Frederick County Department of Planning & Development Department of GIS (Geographic Information Services) Frederick County Sanitation Authority Frederick County Building Inspections Department Frederick County Department of Public Works Frederick County Fire Marshal Frederick County Health Department Frederick County Department of Parks & Recreation Virginia Department of Transportation (VDOT) City of Winchester Town of Stephens City Town of Middletown Frederick County / Winchester Airport Authority (2) One (1) copy of the Site Plan application form. (3) Payment of the site plan review fee. l✓ (4) One (1) reproducible copy of the Site Plan (if required). 'Ole, lvltltldl�, Y14. CASH RECE Date 1 / 0033.57 r ' (j Received From �V k -- Address r j Dollars $a)&). ` For L.l 1. �' I c'C ct-) l t 'ato-L to—, TT�Y� U m AMT OF ACCOUNT CASH � AMT PAID u Vi d BALANCE DOE •.• 'NEY ONDFA HfgTCMD By • u- 0 11 co, J! 121ICK Department of Planning and Development 540/665-5651 FAX: 540/ 665-6395 October 31, 2003 Mr. Dennie D. Dunlap, P.E. Triad Engineering 200 Aviation Drive Winchester, Virginia 22601 RE: Approval, H. P. Hood Wastewater Treatment Plant Expansion; Site Plan #36-03; Property Identification Number (PIN) 63-A-86A Dear Mr. Dunlap: The Frederick County Department of Planning and Development administratively approved the above - referenced plan on October 31, 2003. The plan meets all requirements for development in the M2 (Industrial General) Zoning District. Primary improvements associated with this development include a 100 square -foot addition to the existing electrical building and the placement of two additional wastewater treatment plant tanks on the site. I am providing you with four copies of the approved site plan. Please forward these to the appropriate representatives. Furthermore, please advise the owner that a copy should be kept for future reference and an approved copy must be kept on the construction site throughout the development process. Once site development is complete, the owner should contact this office to schedule an on -site inspection. This is required prior to the issuance of an occupancy permit by the Department of Building Inspections. Sincerely, " 4�94b Rebecca Ragsdale - Planner I cc,,-'v'V- Harrington Smith, Jr., Shawnee District Supervisor % .Alexander, Real Estate em: Wiiams C. Rosenberry and Hebert A. Morris, Shawnee District Planning Commission Members U:,Rebecca�Site Plans�Hood\approval.wpd 107 North Kent Street 0 Winchester, Virginia 22601-5000 L E T T E R O F TONS M ITT A L L:qljii) TRIAD ENGINEERING, INC Geotechnical, Civil, Environmental, Survey, Land Planning and Construction Consultants 200 Aviation Orive P.O. Box 2397 Winchester, VA 22604 (540) 667-9300 (540) 667-ZZ60 fax oKiceCtriad-winc. corn To : Fred. Co. Dept. of Planning & Zoning Date : 31 October 2003 107 N. Kent Street Attention : Rebecca Ragsdale Winchester, VA 22601 Job No.: 07-03-0362 Re: H.P. Hood WWTP Addition Site Plan WE ARE SENDING YOU a Attached ❑ Under separate cover via ❑ Shop Drawings ❑ Prints O Plans ❑ Copy of letter ❑ Change Order ❑ ❑ Samples the following items ❑ Specifications COPIES DATED NUMBER DESCRIPTION 6 08-20-03 C-1 to C-4 H P. Hood WWTP Addition site plan (revised 10-30-03) Request for site plan comments approval sheets from other agencies THESE ARE TRANSMITTED as checked below: 0 For Approval ❑ Approved as submitted ❑ Resubmit ❑ Samples ❑ Approved as noted ❑ Submit _ ❑ As Requested ❑ Returned for corrections ❑ Submit _ ❑ For review and comment ❑ ❑ FOR BIDS DUE: ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO copies for approval copies for distribution copies for distribution SIGNED S)� -D Z If enclosures are not as noted, kindly notify us at once • • L E TT E R O F T R A N S M I TT A L _ 000 Aviation Drive L :RlAli) P.O. Box ZO97 Winchester, VA ZZ604 (540) 667-9300 TRIAD ENGINEERING, INC. (540) 667-ZZ60 fax Geotechnical, Civil, Environmental, office 4triad-winc.con) Survey, Land Planning and Construction Consultants To: Fred. Co. Dept. of Planning & Zoning Date : 30 October 2003 107 N. Kent Street Attention : Rebecca Ragsdale Winchester, VA 22601 Job No.: 07-03-0362 Re: H.P. Hood WWTP Addition Site Plan WE ARE SENDING YOU R3 Attached ❑ Under separate cover via __ the following items ❑ Shop Drawings ❑ Prints 0 Plans ❑ Samples ❑ Specifications ❑ Copy of letter ❑ Change Order ❑ COPIES DATED NUMBER I DESCRIPTION 1 08-20-03 C-1 to C-4 H.P. Hood WWTP Addition site plan (revised 10-30-031 Request for site plan comments approval sheets from other agencies THESE ARE TRANSMITTED as checked below: 21 For Approval ❑ Approved as submitted ❑ Resubn ❑ Samples ❑ Approved as noted ❑ Submit ❑ As Requested ❑ Returned for corrections ❑ Submit ❑ For review and comment ❑ ❑ FOR BIDS DUE: ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO: copies for approval _ copies for distribution copies for distribution SIGNED ��, Z._� .00 If Enclosures are not as noted, kindly notify us at on e P.O. Box 2397 Winchester, VA 22604 Phone 540-667-9300 FAX 540-667-2260 October 30, 2003 Rebecca Ragsdale, Planner I Frederick County Dept. of Planning & Development 107 North Kent Street Winchester, VA 22601 RE: H.P. Hood WWTP Expansion Site Plan #36-03 Triad File CD-07-03-0362 Dear Ms. Ragsdale, The following represents Triad Engineering, Inc. response to your comments enumerated in your letter dated September 9, 2003 (attached). We are responding on a point -by -point basis to correlate with your letter. The previous note #14 on sheet C-2 (now note #19) is revised to indicate that the addition of the two wastewater treatment tanks are the only modification to site plan 04-02. Also, the elements that were proposed for site plan #14-02 are now shown on sheet C-3. Hood Way is labeled on sheet C-3. The zoning and use of the Naomi Poole Adams properties, as well as the zoning of the Potomac Edison property, are shown on sheet C-3. The existing and proposed features for the WWTP are labeled on sheet C-3. The existing features are indicated with dashed lines on sheet C-4. A note specifying that the landscaping plan for the site is indicated on previously approved plans is added to sheet C-2 (see note #1 1). In your review letter, you indicated that you needed an approval letter from VDOT. Since this project does not affect VDOT in any manner (no additional traffic, entrance improvements, etc.) VDOT was not involved in the review process. Please advise if you still require VDOT's approval. Also, FCSA and Engineering did not return a formal comment reply sheet. I have included their approval signatures that were provided on separate forms. Additionally, Hood has previously requested that we use these larger plan sheets to match their original site plan set. I apologize for the inconvenience these larger sheets provide. Should you have any questions, please feel free to contact me anytime. Thank you for your time and consideration regarding this matter. Sincerely, D- Z) fl-/ 777— Dennie D. Dunlap III, P.E. Senior Engineer Triad Engineering, Inc. Morgantown • St. Albans Greensburg Hagerstown Winchester • Harrisonburg • Purcellville West Virginia Pennsylvania Maryland Virginia COUNTY of FREDERICK Department of Planning and Development 540/665-5651 FAX: 540/665-6395 September 9, 2003 Mr. Dcnnie D. Dunlap, P.E. Triad Engineering 200 Aviation Drive P.O. Box 2397 Winchester, Virginia 22601 RE: Review Comments, I -I. P. Hood Wastewater Treatment Plant Expansion; Site Plan #36-03; Property Identification Number (PIN) 63-A-86A Dear Mr. Dunlap: Thank you for the recent submission of the above -referenced site plan. I have completed a review of the plan and would like you to address a few issues in a revision. I have enclosed a red -lined copy of the site plan to clarify the concerns of staff. Please note the comments I have made below. Site Plan # 14-02: On Sheet C-2, general note #14, it is indicated that this is a modification of approved site plan it14-02. Please explain what is modified from that approved site plan. Please update Sheet C-3 to be consistent with what was proposed with the previous site plan # 14-02. For example, the employee parking on that site plan has been installed and is now existing parking but is not shown on the current site plan. 2. Road Information: Label Hood Way on Shect C-3. 3. Adjoining Properties: Please indicate the zoning and use of the Naomi Poole Adams properties, also indicate the zoning of the Potomac Cdison property on Shcct C-3. 4. Proposed Additions: Please label what facilities are already existing at the WWTP and label which are proposed, include this on Shcet C-3 and C-4. 5. Landscaping: 'I'his plan does not illustrate the landscaping plan for the site nor existing woods around the WWTP. tf this 1S 111L1Stl-,ited on a previous site plan, please reference that in your general notes on Sheet C-2, note /E 1 1. 107 North Kent Sheet • Winchester, Virginia 22601-5000 September 9, 2003 Mr. Dennie D. Dunlap, P.E. Re: Review Comments; Sitc Plan 936-03 Page 2 After you have revised the site plan, please resubmit one copy so that I may verify the information contained on the plan. If possible, please reduce the size of the site plan and submit a 24 x 36 inch copy. I will then need all approved review agency comment sheets and five copies of the final site plan for approval. Comment sheets arc required fi-om the following agencies: Building Inspections Department; Frederick County Engineer (Public Works); Frederick County Fire Marshal; Virginia Department of Transportation (VDOT); Frederick County Sanitation Authority; and the Winchester Regional Airport. If you have any questions concerning this review, please do not hesitate to contact me. Sincerely, 10' Qua -� Rebecca Ragsdale, Planner I RAR/bad Enclosure UARebecca\Site fla115\11OOd.wpd 0 • Request For Site Plan Comments Frederick County Fire Marshal -mall Frederick County Fire Marshal Attn: Director of Engineering 107 North Kent Street Winchester, VA 22601 (540) 665-6350 Hand dsliyel' to: 107 N. Kent Street First Floor Winchester, VA (540) 665-6360 Please fill out the information as accurately as possible in order to assist the agency with their review. Please attach two (2) copies of the site plan with this. sheet. Applicant's Name: Triad En ineerin-- Address: 200 Aviation Drive -- - P.O. Box 2397 - -- Winchester, VA 22604 -- -- -- Phone Number: (540) 667-9300 ---- Name of development and/or description of the request:----- H_P. Hood Wastewater Treatment Plant Expansion --- Location of property: 160 Hood Way - Winchester VA 22602 Fire Marshal's Comments: 3{(3 Date received�'a�- Incomplete Date reviewed Signature and Date Signature and Date (revision) Dire and Rescue Dept. use only Date revision received Incomplete 1')ate.revIo,wed . \ Date approved` _ 63 CJ 0 Request For Site Plan Comments Frederick County Inspections Department Mail to: Hand deliver to: Frederick County Inspections Department 107 N. Kent Street Attn: Building Official Fourth Floor 107 North Kent Street Winchester, VA Winchester, VA 22601 (540) 565-5650 (540) 665-5650 Please fill out the information as accurately as possible in order to assist the agency with their review. Please attach one (1) copy of the site plan with this sheet. Applicant's Name: Triad Engineering, Inc. Address: 200 Aviation Drive P.O. Box 2397 Winchester VA 22604 Phone Number: (540) 667-9300 Name of development and/or description of the request: H.P. Hood Wastewater Treatment Plant Expansion Location of property: 160 Hood Way Winchester, VA 22602 Inspections Department Comments: o h1 r, -,F--� 5 ARE d Al %ZI �U6i Inspections Dept. use only Date received ---- Date revision received -- -- Date approved /e e 3 Incomplete -- Inco Ict _ Datc reviewed D c cv' wee -- _ Signature and Date — Sion iture and Date (revision) ------ -- --- �� 0111� • U Mail to: Winchester Regional Airport Attn: Executive Director 491 Airport Road Winchester, VA 22602 (540) 869-2422 Request For Site Plan Comments Winchester Regional Airport Hand deliver to: 491 Airport Road (Route 645, off of Route 522 South) (540) 869-2422 Please fill out the information as accurately as possible in order to assist the agency with their review. Please attach one (1) copy of the site plan with this sheet. Applicant's Name: , t -► r�, Address: le 00 Phone Number: h 10� LL 9- 1 '30C) A Name of development and/or description of the request: l� V- 40C)d D pc:vis ior) Location of property: _� OocCA Winchester Regional Airport Comments Whichester Regional Airport use only Date received Incomplete Date reviewed _ Signature and Date Signature and Date (revision Date revision received Incomplete Date reviewed Date approved 0 24 �J • WINCHESTER REGIONAL AIRPORT SERVING THE TOP OF VIRGINIA / October 16, 2003 Triad Engineering, Inc. 200 Aviation Drive Post Office Box 2397 Winchester, Virginia 22604 491 AIRPORT ROAD WINCHESTER, VIRGINIA 22602 (540) 662-2422 Re: Site Plan Comments H. P. Hood WWTP Addition Shawnee Magisterial District Dear Sir: Following a review of the above referenced site plan, it has been determined that this proposal should not impede operations at the Winchester Regional Airport since it lies outside the airport's Part 77 surfaces and does not exceed height limitations. Should you have questions regarding this matter or need additional information, please do not hesitate to contact our office. Thank you for your continued support. Sincerely, Serena R. Manuel Executive Director SITE PLAN REVIEW SUBMISSION 08/20/2003 0 i CH _s Z roved by the Zoning Administrator IU/ JU/ Zur1J 11: LL 04L)dbdlUbl 0 t1 IJ1Nl., rU5u 0 N_Qa�' 1 Contractor shall field verify locations of all existing utilities prior to initiation of any construction activities. n V� u\ 2. Design depicted hereon is obtained from AEI Systems, Inc. Triad Engineering, Inc. accepts responsibility for only tI­e erosion and sediment control elements of the peon. All utilities, grading, and design specifications associated with the wastewotar treoiment plant (WWTP) are the responsibility of ADI Systems, Inc. The design shall ensure that the point of connection to the existing sanitary sewer line is upstream of the monitoring manhole. 3. Baseline shown rune parallel with the East face of the existing control building. 4. The amount of disturbed area for this project is approximately 20,000 sq. ft. (0.46 acres). 5. Additional storm—woter management Improveme,its cre not needed for this addition. Storm —water management is handled via two existing on —site detention bosln9. 6. The existing gravel roadway to tF:o WWTP from the H.P Hood facility shall serve as the emergency firo access route. `77y/ 5- l 5 T —O D LJ _rO `G 30 el TO-aL P.22 • September 9, 2003 • M FIUI�IAVV COUNrI'Y of FREDERICK Department of Planning and Development 540/ 665-5651 FAX: 540/665-6395 Mr. Dennic D. Dunlap, P.E. Triad Engineering 200 Aviation Drive P.O. Box 2397 Winchester, Virginia 22601 RE: Review Comments, H. P. Hood Wastewater Treatment Plant Expansion; Site Plan #36-03; Property Identification Number (PIN) 63-A-86A Dear Mr. Dunlap: Thank you for the recent submission of the above -referenced site plan. I have completed a review of the plan and would like you to address a few issues in a revision. I have enclosed a red -lined copy of the site plan to clarify the concerns of staff. Please note the comments I have made below. Site Plan # 14-02: On Shect C-2, general note #14, It Is indicated that this is a modification of approved site plan #14-02. Please explain what is modified from that approved site plan. Please Update Sheet C-3 to be consistent with what was proposed with the previous site plan #14-02. For example, the employee parking on that site plan has been installed and is now Existing parking bUt IS not shown on the current site plan. 2. Road Information: Label Hood Way on Sheet C-3. 3. Adjoining Pi-operties: Please indicate the zoning and use of the Naoini Poole Adams properties, also indicate the zoning of the Potomac Edison property on Shect C-3. 4. Proposed Additions: Please label what facilities are already existing at the WWTP and label which are proposed, include this on Shed C-3 and C-4. 5. Landscaping: This plan does not illustrate the landscaping plan for the site nor existing woods around the W WTP. If this is illustrated on a previous site plan, please reference that in your general notes on Sheet C-2, note // 11. 107 North Kent Street • Winchester, Virginia 22601-5000 r � • September 9, 2003 Mr. Dennic D. Dunlap, P.E. Re: Review Comments; Site Plan #36-03 Page 2 After you have revised the site plan, please resubmit one copy so that I may verify the information contained on the plan. If possible, please reduce the size of the site plan and submit a 24 x 36 inch copy. I will then need all approved review agency comment sheets and five copies of the final site plan for approval. Comment sheets are I-CCILUI'ed from the following agencies: BUilding Inspections Department; Frederick County Engineer (Public Works); Frederick County Fire Marshal; Virginia Department of Transportation (VDOT); FI-CdCI-ICI< County Sanitation Authority; and the Winclicster Regional Airport. If you have any questions concerning this review, please do not hesitate to contact me. Sincerely, Rebecca Ragsdale, Planner I RAR/bled Bnc1oSUrC U:\Rebecca\Site Plans\llood.wpd A E:� =o ADI SOems Inc. L�� [ u, 1 red Ret, Street, Suite 300, 91 E3B I��—�� U�/ U Fredericton, NB, Canada 1✓3B 312 G R O U P Tel: (506) 452-7307 Fax: (506) 452-7308 In USA & Canada: 1 800 561 BVFI TRANSMITTAL To: County of Frederick Project No.: 1050-002.1/2.5 ........................... ......................................................................................................................................................................................................................... Department of Planning and Development From: Michael McDermaid ....................................................................................................................................... ..............107 North.Kent S.reel............................................................E:mail:..!n! cmC�adi.ca Winchester, VA 22601 USA Date: August 14, 2003 ........................................................................................................................... ..... ............................................................................................. Phone: Re: Reference Drawings: H.P. Hood Inc. Wastewater Treatment Expansion,. Winchester, VA .......................................................................................................................... ..... .... ........................................ Attention. Mr. Jeremy Came - Planner II .................................................................................................................................................................................................. Shipping Method: ❑ Mail ❑ Bus ❑ Courier ❑ Hand Deliver U Hold For Pick-up Drawing No. Rev. Copies Description and Remarks No. 2- 1 _0 _ __2__ Site Layout and Grading Plan ASI.005\98-4-16 Si nature of Sender Frederick County, Virginia Site Plan Application Site Plan Information Checklist The following information must be included on your site plan. If your site plan is incomplete or is missing information, it will not be reviewed and returned to you for revisions. Administrative Information Y N 1. Name of proposed development. ✓ 2. Name, address, and phone number of owner. _ _ 3. Name, address, and phone number of developer. _ ✓ 4. Name, address, and phone number of designer. - 5. Certificate of surveyor, engineer, or architect. - 6. Date plan prepared and date of revisions. _ 7. A listing of all conditions placed on the site as a result of a conditional use permit or conditional zoning approval. -� - 8. A space labeled "Approved by the Zoning Administrator" for the approval signature and date of approval. _ 9. A description of setbacks or conditions placed on the site as a result of a variance approval. (Reference the variance application number.) General Site Information Y N 10. Location map (scale 1:2000) 11. Magisterial District >✓ __ __ 12. Scale of site plan (not to exceed 1:50) 13. North Arrow __- 14. Zoning of site Ar /Ml L _ 15. Use, zoning, and Property Identification Number (PIN#) of all adjoining properties. This includes properties located across right- of-ways, streams, and railroad tracks. 16. Surveyed boundaries for all lots and parcels. u • Frederick County, Virginia General Site (conA) Y N 17. - 18. --- -- — 19 _ 20 21 22 --- Ao 23 24 ✓ 25 26 Building Information ZY N Roads Y N 35 27. 28 29. 30. Site Plan Application Acreage of all lots included in the plan. The location and dimensions of all required setbacks and yard areas. The location and type of all dwelling units. Location and description of all recreation facilities. Location of sidewalks and pedestrian ways. Location and area of common open space. The location, height, and dimensions of all signs. Location, height, and specifications of outdoor lighting fixtures. Location and nature of outdoor storage areas. Location of outdoor trash receptacles and dimensions of structure (fencing, etc.) required to enclose receptacles. The height of all buildings and structures. Location of all buildings, structures and uses. The proposed use of each building, structure and area. Ground floor area and total floor area of all buildings with FAR_ calculations for commercial and industrial zoning districts. 31. Name and number of existing and planned streets on and adjoining the site. 32. Location of existing and planned streets on and adjoining the site. 33. Posted speed limit of existing adjacent roads. 34. Location and dimensions of all proposed entrances from public right-of-ways. Location of all entrances on adjoining roads within 200 feet of the Frederick County, Virginia Site Plan Application proposed or existing entrance. 36. Dimensions, boundaries, width, pavement, and construction of planned roads. Utilities Y N 37. Location of all utilities, including sewer and water lines with the size of lines, mains, and laterals. 38. Location and width of all easements, including access, utility, and drainage easements. 39. Location and nature of fire lanes, fire hydrants, and all other facilities necessary to meet Fire Code requirements. Parking Y� N 40. Calculations describing the required number of parking and loading spaces. 41. Location and dimensions of all parking and loading spaces, driveways, parking aisles, curbing and other features to be used. 4 42. Location and dimension of all disabled parking spaces and ramps. Natural Features Y N 43. Existing and finished contour lines. 44. Location of steep slopes, woodlands, floodplains, wetlands, sinkholes, and other environmental features. 45. Location of streams and drainage ways. 0 9 Frederick County, Virginia Landscaping Y N 46 47 Erosion and Sediment Control Y N Site Plan Application Landscaping plan describing location and types of plants to be used. Location of required buffers and screening with cross sections or profiles. 48. A stormwater management plan with run off calculations and location and description of facilities to be used. 49. Soil erosion and sedimentation control plan describing the location and methods to be used to minimize erosion and sedimentation during development. �vu ADI Systems Inc. August 15, 2003 Mr. Jeremy Camp Planner II Waste Treatment and Department of Planning and Development Management Systems 107 North Kent Street Winchester, Va 22601 USA Dear Mr. Camp: 1050-2/3.1 RE: Site Plan Review - Wastewater Treatment Plant Expansion - H.P. Hood Inc. Attached please find two copies of original stamped drawing of site plan for expansion to existing wastewater treatment plant building (electrical room addition), location of two additional waste treatment tanks (similar construction as previous tanks), and equipment pad for your review. Detailed drawings have been submitted to Mr. John Trenary at 1133 Regent Street County of Frederick, Department of Public Works/Inspections. Suite 300 Fredericton, NB E313 3Z2 Canada Additional information on project is as follows: Telephone: 506.452.7307 Fax: 506.452.7308 Name of the current owner of the property: E-mail: systemsQadi.ca H.P. Hood Inc. (a Massachusetts corporation) OUR MISSION: Tax map identification number: 63-A-86A Success through satisfied customers Location of property: 160 Hood Way Winchester, VA 22602 Web: www.adi.ca ... /2 Mr. Jeremy Camp Page 2 August 15, 2003 Magisterial district: Back Creek We anticipate site works will begin on September 2, 2003. I will be in the Winchester area until about August 21. Should you have any questions or require any additional information please do not hesitate to contact me at 506-451-7420 (office), 506-449-0903 (cell), 506-452-7308 (fax) or e-mail me at niicm c(Dadi.ca— Regards, l Michael J.C. McDermaid Project Manager MJCM/nap Encls. 0 O 75 u TYPE I FILL TYPE III FT '1 \ umuJ- Lu I r r. 2-2 3—�L_ iV OR FLATTER TO MAi-` X-S_ING —YP TP2 % . -- - 1. 737.80 L . 0 N 7 ,£ ._... -I ..—._ .. ................... —... .... _.._......... ..... .r•I KEYNOTES OREMOVE AND STOCKPILE TOPSOIL FOR REUSE. OREUSE AND STOCKPILE ROADWAY GRANULAR MATERIAL OR TYPE I FILL FOR SWALE FROM C TANKS TO SWALE OUTLET. APPLY 10" MIN THICKNESS. , }'/ - 20' 737.80 \ `\ I jay-, ;� f" '� � \r •"�' 10 -0 ACI-BG EACTOR =2 <:'__f 1 i' j� >v; ,i —(. ) NOTES B i _ ._,..w o 1 _ :i _ r 970o ti7bc �a�` 2 1I I iJ7 a0 CONC ETE FLOG: - TP505 TANK STEEL FLOOR EL. 738 5' �`,_ 737.5c 01 3� TK _ 7� TP y EQI;_PME I 80 TP h. /� .�/� '/ ..ter,. ✓�.�:�:�.: :�:�: � /- �. 2 iu - S - li 4[f `f _ p 1 0 1 1 , I -1 . 737.80 _ IT 7-7.40 L I _ 0' 0'LF 735.00 SLOPE VARIES TYPE (FILL ;0 MATCH EXISTING SURFACE, TYP. OT200 07150 0T10O 0T50 -: t;. T rw _��...- ABBREVIATIONS _._.J DWG - DRAWING POINT DESCRIPTION I STATION (ft) OFFSET (ft) 1 2-2 E/ - EDGE POINT (CORNER OREFERENCE OF BUILDING 0.000 25 EL. - ELEVATION 2 OUTSIDE EDGE OF EXISTING 0-32.5 90.5 TANK AT CENTERLINE INV - INVERT MAX.- MAXIMUM MH.- MANHOLE MIN.- MINIMUM NIC - NOT .IN CONTRACT TYP - TYPICAL OCENTER OF MH I 0-43 51.5 OCENTER OF MH 0-43 116 O5 CENTER OF NEW 84.7' 0 TANK 0-95.5 90.5 OCENTER OF MH 0-118.5 140.5 OCENTER OF MH 148.5 111 OCENTER OF NEW 41 .6' 0 TANK 0-168.5 90.5 _. ,...-.... _ REACTORS,' ......_ AND SBPSj° = L-L 2-5. 2 SCLID LINES DE NOic f PROPOSED WORK 3LIGHT LINES DENO T:_ EXISTING WORK fF� '� I!•fG• f <°';• 4 iLS I— . IT LOCATIONS ARE APPROXIMATE LEG=ND t' - I = - -- _.; : �' _ � _.-••`, 8;1R_=D PIPE PRO E 0 D My i �f, =X_S I _NG MH FINISH GRADE ` I 738.0 LELEGTR?C.AL = �. - (THIS CONTRACT) ROOM .LET=N"w l .—. ._ .......... CWALE 0�000 �tp-ASELI\IE ` III TOP OF SLOPE TOE OF SLOPE UNO - UNLESS NOTED OTHERWISE TYPE I FILL WWTP - WASTEWATER TREATMENT PLANT - CENTERLINE � TP TEST PIT LOCATION EQ - EQUAL ' =" EXISTING SPOT ELEV 0 - DIAMETER 737.80 NEW SPOT ELEV _ - EQUAL TO „••_, -; -,_• CONTOUR ` ROUGH GRADE R - RADIUS SURFACE SLOPE TOC - TOP OF CONCRETE THIS DOCUMENT AND THE INFORMATION, DESIGNS, INVENTIONS,&/OR IMPROVEMENTS CONTAINED HEREIN ARE THE PROPERTY OF ADI & ARE SOLELY FOR USE ON BEHALF OF ADI AND ARE NOT TO BE DISCLOSED, COPIED, OR USED FOR ANY OTHER PURPOSE WHATSOEVER UNLESS SPECIFIC PERMISSION IS FIRST OBTAINED FROM AN AUTHORIZED REPRESENTATIVE OF ADI. NOTE: 1.BASELINE RUNS PARALLEL WITH THE EAST FACE OF THE EXISTING CONTROL BUILDING. 2. SEE DWG 3-1 FOR BASELINE OFFSETS TO EQUIPMENT SLAB. I I t I I I I � I I I No, I Revision ICkd. Byl Date � We ADI Limited ! , Freoedcton. NS, Canada , w Engineenng, Consulting, Procurement and ?rojec, Management Charlottetown, Moncton. Saint John, Truro, Hali:ax. Sydney ?ort Hawkesbury.St.John's.Fredericton and Sal am. NH 2 88.,Cl 1 oC.1 RELEASED FOR CONSTRUCTION ' - Cons:. Nortn 17rawn By: PD D.. Standards 41.S15 O"J By: Designed By: SA . • •. -.` Date Printed Dw . Design 9(tN � Ckc. 5v: t•MOADI Systems Inc. Waste Treatment Systems redericton, NB, CA and Salem, NH, US CAN PATENT •1253266; •2,096,852 USA PATENTS •4,672,691; •5,505,848; •5,567,080 MEXICO PATENT-190RAR Project Title HP HOOD INC. WASTEWATER TREATMENT EXPANSION WINCHES I ER, VA Dwg. Title SITE LAYOUT AND GRADING PLAN Project No. 1 050-2.1 Dwg. No. 2-1 n_1 Rev. No. 0 Scale 1 " = 30.-0" This drowino is not to be scaled 0. -•�.�� � JMTn '--- _ TYPE i FILL SLT-r1F77LE';-Tti -73•; ---__- ��--L._."_ TYPE III Ft`LL`(T�J�-SG•i-L &_HYDROSEED�TYP.) 2-2 -72:: ;/ KEYNOTES OREMOVE AND STOCKPILE TOPSOIL FOR REUSE. OREUSE AND STOCKPILE ROADWAY GRANULAR MATERIAL OR TYPE I FILL FOR SWALE FROM 1 TANKS TO SWALE OUTLET. APPLY 10" MIN THICKNESS. A- iV OR _ :-r,: --- 17)7.8-0 r LATTER I 0 M A I ..- .�.. ----- —.._. .....XISTING, TYP,�`20' 0' TP2 r737.8C 737.80 `I' 1 ( . >(8�.7' - K- 737.90 i _ i �'.} i 2 e�.�. , i g 0 , . - - - P=ACTOR -- :1 2700 ..� �^2 �� sl °'... CONC Lit FL00� c '� J i :i 2-2 AN7 SBRS : t L. 75.E a NK SiE_L FLOOR EL.w/38.,5' \ 3 30-T'K-2 7 � is TP- .. Q _ R . r. _ _ l.DWG 3- V . 2 :. u _ s I. >.lJ I . 0 - I - 'l - ./ n o, , 45 I .. .. Z Q - —737.80't. — - _ ... " 737.40 I i 0, O,L xi ` n � : 38.00. >—......:........ \-S; Op=' VARIES TYPE I FILL _ `�: f -0 MATCH EXISTING SURF ACE, TYP�!_EC I F?C,AL N' 0; 200 07150 0; 100 0 0T50 0 000 AEI TNIE` ~ • `' ABBREVIATIONS POINT I DESCRIPTION OREFERENCE POINT (CQRNER OF BUILDING OOUTSIDE EDGE OF EXISTING TANK AT CENTERLINE OCENTER OF MH OCENTER OF MH OCENTER, OF NEW 84.7' 0 TANK OCENTER OF MH OCENTER OF MH OCENTER OF NEW 41 .6' 0 TANK STATION (ft) I OFFSET (ft) 0.000 25 0-32.5 90.5 0-43 51.5 0-43 116 0-95.5 90.5 0-1 1 8.5 140.5 148.5 1 1 1 0-168.5 90.5 DWG - DRAWING 2-12 E/ - EDGE EL.- ELEVATION INV - INVERT MAX.- MAXIMUM MH. - MANHOLE MIN.- MINIMUM NIC - NOT IN CONTRACT TYP - TYPICAL +N —1 NODS 1 SPECT-TCAT ONS AND GUIDELINES ON DWGS. 2-L & 2-5. 2 SOLID LINES DENOTE PROPOSED WORK 3 LIGHT LINES DENOTE EXISTING WORK L TEST PIT LOCATIONS ARE .APPROXIMATE LEGEI\D BURIED PIPE � PROPOSED 0-c_D MH y EXIS ING MH FINISH GRADE I 738.0 I ELEVATION (THIS CONTRACT) ... ,.. cWALE I1 III TOP OF SLOPE TOE OF SLOPE UNO - UNLESS NOTED OTHERWISE -,1'PE I FILL WWTP - WASTEWATER TREATMENT - PLANT CENTERLINE TP TEST PIT LOCATION EQ - EQUAL =' EXISTING SPOT ELEV 0 - DIAMETER �— 737.80 NEW SPOT ELEV _ - EQUAL TO __. J7 , _• _ CONTOUR ROUGH GRADE R - RADIUS y SURFACE SLOPE TOC - TOP OF CONCRETE THIS DOCUMENT AND THE INFORMATION, DESIGNS, INVENTIONS,&/OR IMPROVEMENTS CONTAINED HEREIN ARE THE PROPERTY OF ADI & ARE SOLELY FOR USE ON BEHALF OF ADI AND ARE NOT TO BE DISCLOSED, COPIED, OR USED FOR ANY OTHER PURPOSE WHATSOEVER UNLESS SPECIFIC PERMISSION IS FIRST OBTAINED FROM AN AUTHORIZED REPRESENTATIVE OF ADI. 000, NOTE: 1. BASELINE RUNS PARALLEL WITH THE EAST FACE OF THE EXISTING CONTROL BUILDING. 2.SEE DWG 3-1 FOR BASELINE OFFSETS TO EQUIPMENT SLAB. I I I I I I I No. Revision ICkd. By Date S!e ADI Limited « I) cngineenng, Ccnsulbng. Procurement and Proie Manacement Charlottetown, Moncton. Saint John, Truro. Halifax, Sydney Port Hawkesbury, St.John•s. Fredericton and Saien:. NH 2889-160.1 RELEASED FOR CONSTRUCTION Ij- ;v-�C'-,,>,e .r Cons:.North J �M aId l Sr.,a1 rJawn By: PD No. 036107 _ l Dwc. Stontlords , f0.`r � 1. Iv- Designed BY: Daze Printed' v ' I Dwg. Design [� µ Ckc. Bv: =10b.loADI Systems Inc. t � �Jrt ; Waste Treatment Systems Fredericton, N3, CA and Salem, NH, US CAN PATENT-1253266: •2,096,852 USA PATENTS -4,672,691;-5,505,848;-5.587,080 MEXICO PATENT-190899 Project Title HP HOOD INC. WASTEWATER TREATMENT EXPANSION WINCHESTER, VA Dwg. Title SITE LAYOUT AND GRADING PLAN Project No. 1 050-2.1 n_1 Dwg. No. 2-1 Rev. No. 0 Scale 1 " = 30.-0" This drawino is not to be scaled • 0 SITE PLAN APPLICATION Department of Planning and Development Use only. Date application received Z7 O Application # _d 1 17 3 M E Complete. Date of acceptance Incomplete. Date of return. Project Title: H P Hood Wastewater Treatment Plant Expansion Location of Property: 160 Hood Way Back Creek Ma isterial District Frederick County, Virginia Property Owner: H.P. Hood Inc. Address: 160 Hood Way Winchester VA 22602 Telephone: 540 868-7701 Applicant/Agent: ADI Systems, Inc. Address: 1133 Regent Street Fredericton NB Canada E3B 3Z2 Telephone: 506 452-7307 Designer: Triad Engineering, Inc. Address: 200 Aviation Drive P.O. Box 2397 Winchester VA 22604 Telephone: 540 667-9300 Contact: Mr. Dennie Dunlap • 6a. Is this a standard or 'minor' site plan? 6b. Is this an original or revised site plan? 7a. Total acreage of parcel to be developed: Total acreage of parcel: 8. Property Information: a) Property Identification Number: b) Current Zoning: c) Present Use: d) Proposed Use: e) Adjoining Property Use(s): 0 Adjoining Property Identification Number(s): g) Magisterial District(s): Standard Minor ✓ Original Revised ✓ 0.20 4.10 63-A-86A M-2 Industrial Industrial V8c1Ilt Coninici-clal IndUstrial, Single-_ Fanjil 63-A-82 63-A-85 75-A-91 A, 63-A-116, 63-A-110 63-A-87 63-A-87A, 63-A-81, 54-A-121 Back -Greek ,Sh (21 ,,w r: I have read the material included in this package and understand what is required by the Frederick County Planning Department. I also understand that all required material will be complete prior to the submission of my site plan. Signature: Date: 5)p- � z4 --z FL S 12- 1 / ° 3 AUG 2, G Z003 0 E S PLIC T The checklist shown below specifies the information which is required to be submitted as part of tlle site plan ent of Planning & Development review notJcohmplete, itwill bereturned to application tel application. The Departmthe complete prior to accepting it. If any portion of the application applicant(s). One (1) set of approved comment sheets are required from each relevant review agency prior to final approval of a site plan. It is recommended that applicants contact the Department of Planning & Development to deternline which review agencies are relevant to their site plan application. A list of potentially relevant review agencies is shown below: / Frederick County Department of Planning & Development Frederick County Sanitation Authority Frederick County Building Inspections Department Frederick County Department of Public Works Frederick County Fire Marshal Frederick County Health Department Frederick County Department of Parks & Recreation Virginia Department of Transportation (VDOT) City of Winchester Town of Stephens City Town of Middletown Frederick County / Winchester Airport Authority GIS (2) One (1) copy of the Site Plan application form. — (3) Payment of the site plan review fec. (4) One (1) reproducible copy of the Site Plan (if required). AU G 2 6 2003 R SITE PLAN CHECKLIST The Site Plan Checklist, shown below, lists the information which is required to be on each site plan. Site plans which are incomplete or missing information, will be returned to the applicant (s) for revision. Project lnforniatiolr Section (1) A title that includes the name of the proposed or existing business and a subtitle which describes the proposed development. (2) The name, address, and phone number of the land owner, developer, and designer. ✓_ (3) The Frederick County Property Identif►cation Number (PTN) of all lots included on the site plan. N �A (4) The number and type of dwelling units included on the site plan for residential uses. (5) The total land area and total developed land area of all lots included on the site plan. (6) A detailed description of the proposed use or uses of the development, as well as a description of the existing use or uses. (7) A reference to any other site plan or master development plan approved by the county for the site. (8) The date the site plan was prepared and a list of all revisions made, including the date and a description of why the site plan was revised. (9) A table of contents including all pages of the site plan. N �Fl (10) A list of all proposed utility providers, with their address, name and phone number. V/ (1 l) An inset map showing the location of the site, along with the location of streets, roads and land uses Within five hundred (500) feet of -the property. N 1A (12) A statement listing all requirements and conditions placed on the land included in the site plan resulting from approval of conditional zoning or a conditional use permit. (13) A description of setbacks or conditions placed on the site as a result of an approved V£lrlance. — (14) The name of the Magisterial District the property is located within. 9 Calculations Section (15) Calculations showing the Floor Area Ration (FAR) of the site, including the maximum allowed FAR, total ground floor area, total floor area, and total lot area. (16) Calculations showing the total number of required and proposed parking spaces, including the total number of existing and proposed spaces. (17) Calculations showing the total number of required handicap spaces, including the total number of existing and proposed spaces. (18) Calculations showing the total number of required loading spaces, including the total number of existing and proposed spaces. N ��( (19) Calculations showing the total number of required perimeter and interior trees required, including the number of provided trees. (20) Calculations showing the percentage of the property that will be landscaped and the percentage of woodlands disturbed. :re Plan & Delails Secti011 (21) The location of all adjoining lots with the owner's name, specific use, zoning, and zoning boundaries shown. on of all existing or planned right-of-ways and easements that adjoin the (22) The locati property, with street names, widths, and speed limits shown. (23) All nearby entrances that are within two hundred (200) feet of any existing or proposed entrances to the site. N �A (24) All existing and proposed driveways, parking and loading spaces, parking lots and a -- description of surfacing material and construction details to be used. The size and angle of parking spaces, aisles, maneuvering areas, and loading spaces shall be shown. (25) A North arrow. (26) A graphic scale and statement of scale. (27) A legend describing all symbols and other features that need description. (28) A boundary survey of the entire parcel and all lots Included with distances described at least to the nearest hundredth of a foot. (29) The present "/.Oning Of aII portions of the site, with the location of" zoning boundaries. (30) "I'hc location of all existing and proposed structures, with the height, specific use; ground floor area, and total floor area labeled. (31) 'I -he location of all existing and proposed outdoor uses, with the height, specific use, and land area labeled. 10 • (32) Existing topographic contour lines at intervals acceptable to the Zoning Administrator. Proposed finished grades shall be shown by contour. (33) The location of the front, side, and rear yard setback lines required by the applicable zoning district. ng (34) The location and akes and boundaries onds, wetlands,inaenvironmental turalstormwater retent on areas, steept slopes, floodplplainarns, 1 P and woodlands. N /A (35) The location of outdoor trash receptacles. _ (36) The location of all outdoor lighting Fixtures. N A (37) The location, dimensions, and height of all signs. �A (38) The location of required buffers, landscaping buffers, and landscaped screens, including /J _ examples, typical cross sections or diagrams of screening to be used. The location and dimensions of required fencing, berms, and similar features shall be specified. N 1A (39) The location of recreational areas and common open space. A(40) The location of all proposed landscaping with a legend. The caliper, scientific name, and common name of all deciduous trees. The height at planting, scientific name, and common name of all evergreen trees and shrubs. N �A -- (41) The height at planting, caliper, scientific name, and common name shall be provided for all proposed trees. The height at planting, scientific name and common name shall be provided for all shrubs. N 1A (42) The location of sidewalks and walkways. (43) "file location and width of proposed easements and dedications. (44) A stormwater management plan describing the location of all stormwater management Facilities with design calculations and details. (45) A soil erosion and sedimentation plan describing methods to be used. (46) The location and size of sewer and water mains and laterals serving the site. (47) (_18) Facilities necessary to meet the requirements of the Fire Code. A signed seal of the certified Virginia land surveyor, architect, or engineer who prepared the plan. (49) A space labeled "Approved by the Frederick County Zoning Administrator' for the; signature Oftl1C Zoning Administrator, applOval (lateand a statement that reads `Site plan valid for five (5) years from approval date." ; AUG 2 v 2003 • • L E TT E R D F T R A N S M I T T A L TRIAD ENGINEERING, INC. Geotechnical, Civil, Environmental, Survey, Land Planning and ZOO Aviation Drive P.O. Box 2397 Winchester, VA 22604 (540) 667-9300 (540) 667-2260 fax office@triad-winc.com To: Fred. Co. Dept. of Planning & Zoning Date : 22 August 2003 107 N. Kent Street Attention : Jeremy Camp Winchester, VA 22601 Job No.: 07-03-0362 Re: H.P. Hood WWTP Addition Site Plan WE ARE SENDING YOU 0 Attached ❑ Under separate cover via ❑ Shop Drawings ❑ Prints Z Plans ❑ Copy of letter ❑ Change Order ❑ ❑ Samples the following items ❑ Specifications COPIES DATED NUMBER DESCRIPTION 2 08-20-03 C-1 to C-4 H.P. Hood WWTP Addition site plan 1 Request for site plan comments 1 Site plan application & checklist 1 08-22 03 41970 Minor site plan review fee check payable to "County of Frederick" for $500 THESE ARE TRANSMITTED as checked below ❑ For Approval ❑ Approved as submitted ❑ Resubmit copies for approval ❑ Samples ❑ Approved as noted ❑ Submit copies for distribution ❑ As Requested ❑ Returned for corrections ❑ Submit copies for distribution 0 For review and comment ❑ ❑ FOR BIDS DUE ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS. COPY TO SIGNED If enclosures are not as noted, kindly notify us at once • 0 Request For Site Plan Comments Department of Planning and Development Mail to: Hand deliver to: Department of Planning and Development 107 N. Fourth KentFlooStreet Attn: County Planner Winchester, VA 107 North Kent Street (540) 665-5651 Winchester, VA 22601 (540) 665-5651 Please fill out the information as accurately as possible in order to assist the agency with their review. Please attach two (2) copies of the site plan with this sheet. Applicant's Name: Triad Engineering, Inc. Address: 200 Aviation Drive P.O. Box 2397 Winchester VA 22604 Phone Number: .(540) 667-930 Name of development and/or description of the request: H.P. Hood Wastewater Treatment Plant Expansion Location of property: 160 Hood Way Winchester VA 22602 Planning and Development's Comments: PI•innin�7 and Development use only Dale rcccived Date revision rcccived Date approved Incomplete Incomplete Date reviewed Dale reviewed Si`(,nature and Date Signature and Date (revision) AUG ? rj 2003