HomeMy WebLinkAbout18-05 Cingular Wire. - Hunt. Ridge - 6 Panel Atennas & Shelter - Gainesboro - Backfile (2)ill lLdW11_ L�J LL --
FREDERICK COUNTY
I,, I APPROVAL BLOCK
ON NG ADMINISTRATOR DATE
* SITE PLAN WILL BE VALID FOR A PERIOD OF FIVE (5) YEARS FROM THE DATE OF APPROVAL.
'11 M4 � 4 ho'l l��
CONDITIONS:
1. ALL ZONING ORDINANCE REQUIREMENTS AND REVIEW AGENCY COMMENTS SHALL BE ADDRESSED AND COMPLIED WITH AT ALL TIMES.
2. THE TOWER SHALL BE AVAILABLE FOR LOCATING PERSONAL WIRELESS SERVICE PROVIDERS,
3. A MINOR SITE PLAN IS APPROVED BY THE COUNTY.
4. THE TOWER SHALL BE REMOVED BY THE APPLICANT OR LANDOWNER WITHIN TWELVE (12) MONTHS OF THE ABANDONMENT OF OPERATION.
DATE
CINGULAR WIRELESS RF APPROVAL
PRINT NAME
SIGNATURE DATE
, q
p
N
K
,
,.
Hi
VICINITY AP
(SCALE 1:2000)
DIRECTIONS:
FROM HANOVER /GREENBELT: GO SOUTHWEST ON STANDARD DR TOWARD PARKWAY DR, TURN LEFT ONTO PARKWAY DR. TURN RIGHT ONTO PARK
CIRCLE DR. PARK CIRCEL BECOMES COCA COLA DR. MERGE ONTO MD-100 W. MERGE ONTO US-29 N / COLUMBIA PIKE TOWARD 1-70. MERGE ONTO
1-70 W TOWARD FREDERICK. MERGE ONTO US-340 S TOWARD BEER RYVILLE/LEESBURG. MERGE ONTO VA-7 W / BERRYVILLE PIKE TOWARD
WINCHESTER. MERGE ONTO 1-81 N TOWARD MARTINSBURG. TAKE US-11 EXIT 317 TOWARD VA-37 / WINCHESTER /US-522 N/ US-50 W, MERGE
ONTO VA-37 S. TAKE US-5D EXIT TOWARD WINCHESTER/ROMNEY. TURN RIGHT ONTO NORTHWESTERN PIKE US-50 W.
�y
10
��- SITE
J�
O .
TRUE NORTH
PROJECT CONTACT
1. CINGULAR REPRESENTATIVE:
4. OWNER CONTACT
MIKE BAKER CONSTRUCTION MANAGER
(443) 694-4062
MIKE.BAKERQCINGULAR.COM
SPENCER LEECH CROWN ATLANTIC COMPANY LLC (301) 931-9267
2. ENTREX PROJECT MANAGER
5. ELECTRIC COMPANY
CABOT GOUDY PROJECT MANAGER
(202) 408-0960
CGOUDYCENTREX,COM
ALLEGHENY POWER
3. CINGULAR CONSTRUCTION MANAGER
6. TELEPHONE COMPANY
BUD GILL CONSTRUCTION MANAGER
(410) 245-9977
BUD.GILLQCINGULAR.COM
VERIZON
SHEET INDEX
T-1 TITLE SHEET
C-1 SITE PLAN
COMPOUND LAYOUT PLAN AND GENERAL NOTES
7-2 MONOPOLE ELEVATION
PROJECT DESCRIPTION
1, INSTALL 6 PANEL ANTENNAS ON EXISTING 180' MONOPOLE. (3 FUTURE)
2. INSTALL 10'x20' EQUIPMENT SHELTER INSIDE EXISTING COMPOUND AREA.
3. PROVIDE NEW ELECTRICAL SERVICE FROM EXISTING DEMARCATION POINT.
4. PROVIDE TELCO SERVICE FROM EXISTING DEMARCATION POINT.
5. RUN ANTENNA SIGNAL AND GROUNDING CABLES.
SITE OWNER:
CROWN CASTLE USA
APPLICANT:
CINGULAR WIRELESS
4700 CORRIDOR PLACE SUITE D
7150 STANDARD DR.
BELTSVILLE, MD 20705
HANOVER, MD 21076
LATITUDE:
N 39° 12' 54.73"
ZONING:
RESIDENTIAL
LONGTITUDE:
W 78° 16' 00.08"
DEED:
-
GROUND ELEVATION:
840' AMSL
-
JURISDICTION:
FREDERICK
CODE DATA:
USE:
U
\ I/
(p entrex
communication services, in
1575 Eye Street, N.W. Suite 350
WASHINGTON, D.C. 20005
PHONE: (202)408-0960
FAX: (202)408-0961
SUBMITTALS
DATE DESCRIPTION REV.
05-20-05 ZONING
SEAL:
■
cingular
. . . . . . . . . . . .
WIRELESS
7150 Standard Dr.
Hanover, MD 21076
PROJECT NO: 1087.015
DESIGNER: K.H.
ENGINEER: H.M.
SCALE:
0 1 2 1
GRAPHIC SCALE IN INCHES
HUNTING RIDGE
1234
4156 NORTHWESTERN PIKE
WINCHESTER, VA 22603
TI TLE:
TITLE SHEET
SHEET NUMBER:
T-1
9
a
�oo
4J
VICINITY MAP
LAND OWNER:
CALVIN L. AND LILLIE J. RITTER
152 LINDEN DRIVE
WINCHESTER, VIRGINIA 22603
SETBACK TABLE
(:t)
TRUE NORTH
HEIGHT OF TOWER = 180'
MAX. HEIGHT = 35'
APPLICABLE SETBACK FOR CERTAIN STRUCTURES THAT
EXCEED 35' IN HEIGHT - 1' PER 1' OF HEIGHT OVER 35'
(180'-35') X 1' ADDITIONAL SETBACK = 145' ADDITIONAL
SETBACK REQUIRED SETBACKS - RA (RURAL AREA) DISTRICT
FREDERICK COUNTY
APPROVAL BLOCK
ZONING ADMINISTRATOR DATE
(GAINESBORO MAGISTERIAL DISTRICT,
FREDERICK COUNTY, VIRGINIA)
50'
FROM
PROPERTY LINES (ADJOINING PROP. -
VACANT OR RESIDENTIAL)
100'
FROM
PROPERTY LINES (ADJOINING PROP.
- AGRICULTURAL)
200'
FROM
PROPERTY LINES (ADJOINING PROP.
- ORCHARD)
60' FROM ALL RIGHT OF WAYS
TOWER SETBACK (PRE -WAIVER)
GENERAL NOTES:
195' FROM PROPERTY LINES
205' FROM RIGHT OF WAY
I. THIS SITE PLAN GENERATED FROM INFORMATION TAKEN FROM
SITE PLAN GENERATED BY PHR&A, NOVEMBER 1999 TITILED
"SITE PLAN, SITE WN203 FOR CFW WIRELESS".
2. THIS PARCEL IS NOT IN A F.E.M.A. FLOOD HAZARD ZONE "A"
OR "B„
V /
TAX MAP 40 ((A)) 154
KEITH J. & MICHELLE D. DAVIS
D.B. 729 PG. 358 /
ZONED: RA // PROPERTY LINE
RESIDENTIAL DWELLING
TAX MAP 40 ((A)) 153
CALVIN L. & LILLIE J. RITTER
D.B. 388 PG, 160
ZONED: RA
RESIDENTIAL DWELLING
TAX MAP 40 ((A)) 152
CALVIN L. & LILLIE J. RITTER
D.B. 713 PG. 209
ZONED: RA
RESIDENTIAL DWELLING
TAX MAP 40 ((A)) 151
CALVIN L. & LILLIE J. RITTER
D.B. 713 PG, 209
ZONED: RA \
RESIDENTIAL DWELLING
TAX MAP 40- ((A)) 150
RAYMOND S. & BETTY L. KERNS
ZONED: RA
RESIDENTIAL DWELLING
TAX MAP 40 ((A)) 164
NONNIE F. & THEODORE L. COX
\ \ D.B. 449 PG. 407
\ ZONED: RA
< TAX MAP 40 ((A)) 153 \\ \ VACANT
\ CALVIN L. & LILLIE J. RITTER \
D.B. 388 PG. 160 \
ZONED: RA \
\ RESIDENTIAL DWELLING \
\ \
EXISTING OVERHEAD POWER/TELCO
EXISTING ACCESS ROAD \
GRAVEL ACCESS DRIVE \ \
\
�
1
i
i
TAX MAP 40 ((A)) 149
RICKY LEE KERNS
D.B. 690 PG. 68
ZONED: RA
RESIDENTIAL DWELLING
3D%/40% GRADE \ \
(TO BE REPAIRED) \
POWERPOLE \
1060152
ALLG POWER \>
/ `—EXISTING SITE /
COMPOUND, SEE 1 /Z-1 / /
UNDERGROUND POWER AND
TELCO CONDUITS /
eq /
_ O/v
1p
� o
SITE PLAN
SCALE: 1 "=200'-0" C-1
TRUE NORTH
TAX MAP 40 ((A)) 145
EVERETT & LILLIAN R. KIBLER
D.B. 351 PG. 420
ZONED: RA
VACANT
— TAX MAP 40 ((A)) 147
JEFFERY W. & APRIL E. WHITACRE
D.B. 852 PG. 1022
ZONED: RA
RESIDENTIAL DWELLING
/
\1
(p entrex
communication services, in
1575 Eye Street, N.W. Suite 350
WASHINGTON, D.C. 20005
PHONE: (202)408-0960
FAX: (202)408-0961
SUBMITTALS
DATE DESCRIPTION REV.
05-20-05 ZONING
I SEAL:
cing ular
WIRELESS
7150 Standard Dr.
Hanover, MD 21076
PROJECT NO: 1087.015
DESIGNER: TMF
ENGINEER: H.M.
SCALE:
0 1 2 1
GRAPHIC SCALE IN INCHES
HUNTING RIDGE
1234
4156 NORTHWESTERN PIKE
WINCHESTER, VA 22603
TITLE:
SITE PLAN
40-A-153
SHEET NUMBER:
C-1
GENERAL NOTES
1. THE PLANS SHOW SOME SUBSURFACE STRUCTURES, ABOVEGROUND STRUCTURES AND/OR OTHER FEATURES FROM FIELD MEASUREMENTS OR
RECORD MAPPING, EXACT LOCA11ON OF WHICH MAY VARY FROM THE LOCATIONS INDICATED. IN PARTICULAR THE CONTRACTOR IS WARNED THAT
THE EXACT LOCATION OF SUCH EXISTING FEATURES IN THE AREA MAY BE DIFFERENT FROM THAT SHOWN OR MAY NOT BE SHOWN, AND IT
SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROCEED WITH GREAT CARE IN EXECUTING ANY WORK. 48 HOURS BEFORE YOU DIG, DRILL OR
BLAST, CALL MISS UTILITY FOR THE MARKING OF EXISTING UTILITY LOCATIONS,
2. THE ENGINEER SHALL BE NOTIFIED IN WRITING OF ANY CONDITIONS THAT VARY FROM THOSE SHOWN ON THE PLANS. THE CONTRACTOR'S
WORK SHALL NOT VARY FROM THE PLANS WITHOUT THE EXPRESSED APPROVAL OF THE ENGINEER.
3. WORK SHALL COMPLY WITH CURRENT ISSUES OF ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. ALL NECESSARY LICENSES,
CERTIFICATES, ETC., REQUIRED BY AUTHORITIES HAVING JURISDICTION SHALL BE PROCURED AND PAID FOR BY THE CONTRACTOR.
4. ENTREX COMMUNICATION SERVICES (ENTREX) HAS NOT CONDUCTED, NOR DOES IT INTEND TO CONDUCT ANY INVESTIGATION TO DETERMINE
THE PRESENCE OF ANY HAZARDOUS MATERIAL INCLUDING BUT NOT LIMITED TO ASBESTOS AND PCB'S WITHIN THE CONFINES OF THIS PROJECT.
ENTREX WILL NOT ACCEPT ANY RESPONSIBILITY FOR THE ABATEMENT OR RESULTING CLAIMS FOR DAMAGES OR LOSSES AS A RESULT OF THE
PRESENCE OF HAZARDOUS MATERIALS. IF EVIDENCE OF HAZARDOUS MATERIALS IS DISCOVERED, SUSPEND WORK AS REQUIRED BY GOVERNING
STATUTES, AND NOTIFY CINGULAR WIRELESS. DO NOT PROCEED WITH WORK UNTIL INSTRUCTED BY CINGULAR WIRELESS.
5. ALL MATERIAL FURNISHED UNDER THIS CONTRACT SHALL BE NEW UNLESS NOTED OTHERWISE, ALL WORK SHALL BE GUARANTEED AGAINST
DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF TWELVE MONTHS FOLLOWING SUBSTANTIAL COMPLETION OF PROJECT OR AS
SPECIFIED, THE CONTRACTOR SHALL REPAIR OR REPLACE AT HIS EXPENSE ALL WORK THAT MAY DEVELOP DEFECTS IN MATERIALS OR
WORKMANSHIP WITHIN THE WARRANTY PERIOD.
6. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR ARE TO BE RESPONSIBLE FOR VERIFYING EXISTING SITE CONDITIONS AND DIMENSIONS
AND THE LOCATION OF BURIED UTILITIES AT THE JOB SITE PRIOR TO THE COMMENCEMENT OF WORK. NOTIFICATION MARKING TO BE DONE BY
MISS UTILITY. NO CLAIMS FOR EXTRA COMPENSATION FOR WORK RESULTING FROM CONFLICTS AND OMISSIONS WHICH COULD HAVE BEEN
DISCOVERED BY FIELD VERIFICATION AND INSPECTION, WHETHER INDICATED ON THE CONTRACT DOCUMENTS OR NOT, WILL BE ENTERTAINED OR
PAID.
7. FOLLOW MANUFACTURERS' PRINTED SPECIFICATIONS AND INSTRUCTIONS EXCEPT WHERE SPECIFIED OR INDICATED ON CONTRACT DOCUMENTS.
COMPLY WITH THE MOST STRINGENT INSTRUCTIONS.
8. THE CONTRACTOR SHALL VERIFY AND COORDINATE SIZE AND LOCATION OF ALL OPENINGS FOR STRUCTURAL MECHANICAL, ELECTRICAL,
PLUMBING. CIVIL OR ARCHITECTURAL WORK.
9. THE CONTRACTOR SHALL VERIFY THAT THERE ARE NO CONFLICT5 AMONG THE LOCATIONS OF ANY MECHANICAL, ELECTRICAL, PLUMBING, OR
STRUCTURAL ELEMENTS, AND THAT ALL REQUIRED CLEARANCES AND CONSTRUCTION TOLERANCES FOR INSTALLATION AND MAINTENANCE ARE
PROVIDED. NOTIFY VELOCITEL OF ANY CONFLICTS. VELOCITEL RESERVES THE RIGHT TO MAKE MINOR MODIFICATIONS TO THE DESIGN WITHOUT
ALTERING THE CONTRACT PRICE.
10. DO NOT SCALE DRAWINGS. DIMENSIONS ARE EITHER TO THE FACE OF FINISHED ELEMENTS OR TO THE CENTER LINE OF ELEMENTS, UNLESS
NOTED OTHERWISE. CRITICAL DIMENSIONS SHALL BE CONFIRMED WITH SITE MEASUREMENTS. VERIFY WITH VELOCITEL AS APPLICABLE.
11. THE CONTRACTOR IS RESPONSIBLE FOR DAILY CLEAN UP OF SITE AND REMOVAL AND DISPOSAL OF ALL CONSTRUCTION DEBRIS. AT THE
COMPLETION OF THE PROJECT THE CONTRACTOR SHALL THOROUGHLY CLEAN THE BUILDING SITE AND ANY OTHER SURROUNDING AREAS TO THE
SATISFACTION OF CINGULAR WIRELESS.
12. THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE,
BREAKAGE, COLLAPSE, ETC., ACCORDING TO APPLICABLE CODES. STANDARDS AND GOOD CONSTRUCTION PRACTICES.
13. ALL WORK SHALL BE DONE IN STRICT COMPLIANCE WITH ALL APPUCABLE NATIONAL, STATE AND LOCAL CODES, STANDARDS, ORDINANCES,
RULES AND REGULATIONS.
14. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR DAMAGES TO THE EXISTING FACILITY AND INSTALLATIONS RESULTING FROM
CONSTRUCTION AND GENERAL NEGLIGENCE. REPAIR ALL DAMAGES AND RESTORE FACILITY AND INSTALLATIONS TO THE SATISFACTION OF
CINGULAR WIRELESS AND LANDLORD AT NO EXTRA CHARGE. NOTIFY CINGULAR WIRELESS AND TOWER OWNER OF ANY SUCH DAMAGES PROMPTLY.
REPAIR TO 100% SATISFACTION IMMEDIATELY.
15. WHERE ONE DETAIL IS SHOWN FOR ONE CONDITION, UNLESS NOTED OTHERWISE, IT SHALL APPLY FOR ALL LIKE OR SIMILAR CONDITIONS,
EVEN THOUGH NOT SPECIFICALLY MARKED ON THE DRAWINGS.
16. WHERE NEW PAVING, CONCRETE SIDEWALKS, OR PATHS MEET EXISTING CONSTRUCTION, THE CONTRACTOR SHALL MATCH THE EXISTING PITCH,
GRADE, AND ELEVATION TO MAINTAIN CONTINUITY, AND A SMOOTH TRANSITION.
17, CINGULAR REPRESENTATIVE IS (RESPONSIBLE FOR APPLYING FOR COMMERCIAL POWER CONNECTION, CONTRACTOR IS RESPONSIBLE FOR
COORDINATION OF UTILITY INSPECTIONS AND POWER COMPANY INSTALLATION, THE GENERAL CONTRACTOR IS REQUIRED TO KEEP ALL
DOCUMENTATION RECEIVED FROM THE POWER COMPANY. WRITTEN AND VERBAL DISCUSSIONS WITH THE POWER COMPANY, ETC.
18. CONTRACTOR WILL PROVIDE TEMPORARY POWER FOR CONSTRUCTION. GENERAL CONTRACTOR AND HIS SUBCONTRACTORS ARE NOT ALLOWED
TO CONNECT TO ANY EXISTING UTILITIES ON THE SITE.
19. DRAWINGS FORMING THIS SET ARE COMPLIMENTARY AND MUST BE READ AS ONE TOTAL DOCUMENT, DRAWINGS AND SPECIFICATIONS ARE
THE PROPERTY OF CINGULAR WIRELESS, THESE DRAWINGS WERE PREPARED TO BE SUBMITTED TO GOVERNMENTAL BUILDING AUTHORITIES FOR
REVIEW FOR COMPLIANCE WITH APPLICABLE CODES. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO EXECUTE CONSTRUCTION
INDICATED HEREIN ACCORDING TO APPLICABLE BUILDING CODES.
20. IF THE CONTRACTOR OR SUBCONTRACTOR FINDS IT NECESSARY TO DEVIATE FROM ORIGINAL APPROVED PLANS, IT IS THE CONTRACTOR'S
AND THE SUBCONTRACTOR'S RESPONSIBILITY TO PROVIDE VELOCITEL THE PROPOSED CHANGES FOR VELOCITEL AND CINGULAR WIRELESS TO
REVIEW AND APPROVE PRIOR TO PROCEEDING WITH SUCH CHANGES. IN ADDITION, THE CONTRACTOR AND SUBCONTRACTORS SHALL BE
RESPONSIBLE FOR PROCURING ALL NECESSARY APPROVALS FROM THE BUILDING AUTHORITIES FOR THE PROPOSED CHANGES PRIOR TO
PROCEEDING WTH THE REVISED WORK. THE CONTRACTOR AND SUBCONTRACTORS ARE RESPONSIBLE FOR PROCURING ALL NECESSARY
INSPECTIONS AND APPROVALS FROM BUILDING AUTHORITIES DURING THE EXECUTION OF THE WORK.
21. THESE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS SHALL BE INTERPRETED TO BE A MINIMUM ACCEPTABLE STANDARD FOR
CONSTRUCTION. THESE DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR, SUBCONTRACTOR, AND/OR SUPPLIER/MANUFACTURER FROM
PROVIDING A COMPLETE AND CORRECT INSTALLATION SHOULD ADDITIONAL ITEMS AND DETAILS BE REQUIRED FOR PROPER AND SAFE
INSTALLATION,
22. THESE CONTRACT DOCUMENTS AND SPECIFICATIONS DO NOT CREATE A CONTRACTUAL RELATIONSHIP OF ANY KIND BETWEEN VELOCITEL AND
THE CONTRACTOR.
23. THE SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, AND LABOR DEEMED NECESSARY TO COMPLETE THE
WORK/PROJECT DESCRIBED HEREIN.
24, THE CONTRACTOR SHALL OBTAIN AUTHORIZA11ON FROM VELOCITEL (THE CINCULAR REPRESENTATIVE) TO PROCEED WITH CONSTRUCTION
PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS.
25. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR
ALL THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK
UNDER CONTRACT.
26. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT AND MAINTAIN EXISTING CONDITIONS, EASEMENTS, PAVEMENTS,
CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, THE CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE
OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY.
27. THE CONTRACTOR SHALL MAINTAIN ALL TRAFFIC IN ALL AREAS IN ACCORDANCE WITH THE VIRGINIA DOT STANDARDS FOR TRAFFIC
CONTROL.
28. THE CONTRACTOR SHALL NOTIFY THE CINCULAR REPRESENTATIVE WHERE A CONFLICT OCCURS ON ANY OF THE CONTRACT DOCUMENTS. THE
CONTRACTOR IS NOT TO ORDER MATERIAL OR CONSTRUCT ANY PORTION OF THE WORK THAT IS IN CONFLICT UNTIL IT IS RESOLVED BY THE
CINGULAR REPRESENTATIVE.
29. CONTRACTOR TO SCHEDULE AND COORDINATE WITH CINGULAR VENDOR, A 3RD PARTY INSPECTION FOR FOUNDATION, SWEEP TEST, AND
ANTENNA ORIENTATION.
EXISTING ICEBRIDGE
EQUIPMENT LOCATION PLAN
SCALE: 1 /4"=1'-0"
FREDERICK COUNTY
APPROVAL BLOCK
ZONING ADMINISTRATOR
(GAINESBORO MAGISTERIAL DISTRICT,
FREDERICK COUNTY, VIRGINIA)
TRUE NORTH
DATE
\I/
(p entrex
communication services, in
1575 Eye Street, N.W. Suite 350
WASHINGTON, D.C. 20005
PHONE: (202)408-0960
FAX: (202)408-0961
SUBMITTALS
DATE DESCRIPTION REV.
05-20-05 ZONING
SI EAL:
c i n g u a r
WIRELESS
7150 Standard Dr.
Hanover, MD 21076
PROJECT NO: 1087.015
DESIGNER: K.H.
ENGINEER: H.M.
SCALE:
0 1 2 1
GRAPHIC SCALE IN INCHES
HUNTING RIDGE
1234
4156 NORTHWESTERN PIKE
WINCHESTER, VA 22603
TITLE:
COMPOUND LAYOUT
PLAN AND
GENERAL NOTES
SHEET NUMBER:
Z-1
PROPOSED CINGULAR ANTENI
(6 PRESENT/3 FUTURE) SEE
AZIMUTH (0% 120% 240')
EXISTING 18(
rviOTIKI(l PDA/ nnITUNInInc
MONOPOLE ELEVATION 1
SCALE: 3/32"=1'-0" Z-2
(GAINESBORO MAGISTERIAL DISTRICT,
FREDERICK COUNTY, VIRGINIA)
\ I/
(p entrex
communication services, in
1575 Eye Street, N.W. Suite 350
WASHINGTON, D.C. 20005
PHONE: (202)408-0960
FAX: (202)408-0961
SUBMITTALS
DATE DESCRIPTION REV.
11-08-04 85% CONSTRUCTION
11-29-04 90% CONSTRUCTION
SEAL:
35
cing ular
WIRELESS
7150 Standard Dr.
Hanover, MD 21076
PROJECT NO: 1087.015
DESIGNER: K.H.
ENGINEER: H.M.
SCALE:
0
GRAPHIC SCALE IN INCHES
HUNTING RIDGE
1234
4156 NORTHWESTERN PIKE
WINCHESTER, VA 22603
TITLE:
MONOPOLE
ELEVATION
SHEET NUMBER:
Z-2
�� r I, i�l I� ��i�:. i I i1_I. �l. I� _ 1 _ �:I_.i. I -L -
19
7
_ 1—' — —
ZONING ADMINISTRATOR
* SITE PLAN WILL BE VALID FOR A PERIOD OF FIVE (5) YEARS FROM THE DATE OF APPROVAL.
r-
CONDITIONS:
1. ALL ZONING ORDINANCE REQUIREMENTS AND REVIEW AGENCY COMMENTS SHALL BE ADDRESSED AND COMPLIED WITH AT ALL TIMES.
2. THE TOWER SHALL BE AVAILABLE FOR LOCATING PERSONAL WIRELESS SERVICE PROVIDERS.
3. A MINOR SITE PLAN IS APPROVED BY THE COUNTY.
4. THE TOWER SHALL BE REMOVED BY THE APPLICANT OR LANDOWNER WITHIN TWELVE (12) MONTHS OF THE ABANDONMENT OF OPERATION,
DATE
DATE
VICINITY MAP
(SCALE : 0 0)
DIRECTIONS:
FROM HANOVER/GREENBELT: GO SOUTHWEST ON STANDARD DR TOWARD PARKWAY DR. TURN LEFT ONTO PARKWAY DR. TURN RIGHT ONTO PARK
CIRCLE DR. PARK CIRCEL BECOMES COCA COLA DR. MERGE ONTO MD-100 W. MERGE ONTO US-29 N / COLUMBIA PIKE TOWARD 1-70. MERGE ONTO
1-70 W TOWARD FREDERICK. MERGE ONTO US-340 S TOWARD BEER RYVILLE/LEESBURG. MERGE ONTO VA-7 W / BERRYVILLE PIKE TOWARD
WINCHESTER. MERGE ONTO 1-81 N TOWARD MARTINSBURG. TAKE US-11 EXIT 317 TOWARD VA-37 / WINCHESTER /US-522 N/ US-50 W. MERGE
ONTO VA-37 S. TAKE US-50 EXIT TOWARD WINCHESTER/ROMNEY. TURN RIGHT ONTO NORTHWESTERN PIKE US-50 W.
SITE
4
J�
0
TRUE NORTH
PROJECT CONTACTS
1, CINGULAR REPRESENTATIVE:
4. OWNER CONTACT
MIKE BAKER CONSTRUCTION MANAGER
(443) 694-4062
MIKE.BAKER@CINGULAR.COM
SPENCER LEECH CROWN ATLANTIC COMPANY LLC (301) 931-9267
2. ENTREX PROJECT MANAGER
5. ELECTRIC COMPANY
CABOT GOUDY PROJECT MANAGER
(202) 408-0960
CGOUDY@ENTREX.COM
ALLEGHENY POWER
3. CINGULAR CONSTRUCTION MANAGER
6. TELEPHONE COMPANY
BUD GILL CONSTRUCTION MANAGER
(410) 245-9977
BUD.GILL@CINGULAR.COM
VERIZON
110
T-1 TITLE SHEET
C-i SITE PLAN
Z-1 COMPOUND LAYOUT PLAN AND GENERAL NOTES
7-2 MONOPOLE ELEVATION
PROJECT DESCRIPTION
1. INSTALL 6 PANEL ANTENNAS ON EXISTING 180' MONOPOLE. (3 FUTURE)
2. INSTALL 10'x20' EQUIPMENT SHELTER INSIDE EXISTING COMPOUND AREA.
3. PROVIDE NEW ELECTRICAL SERVICE FROM EXISTING DEMARCATION POINT.
4. PROVIDE TELCO SERVICE FROM EXISTING DEMARCATION POINT.
5. RUN ANTENNA SIGNAL AND GROUNDING CABLES.
SITE OWNER: CROWN CASTLE USA APPLICANT: CINGULAR WIRELESS
4700 CORRIDOR PLACE SUITE D 7150 STANDARD DR.
BELTSVILLE, MD 20705 HANOVER, MD 21076
LATITUDE: N 39' 12' 54.73" ZONING: RESIDENTIAL
LONGTITUDE: W 78° 16' 00.08" DEED: —
GROUND ELEVATION: 840' AMSL —
JURISDICTION- FREDERICK CODE DATA: USE: U
\1/
c9p entrex
communication services, in
1575 Eye Street, N.W. Suite 350
WASHINGTON, D.C. 20005
PHONE: (202)408-0960
FAX: (202)408-0961
SUBMITTALS
DATE DESCRIPTION REV.
05-20-05 ZONING
. . . . . . . . . M..,s: cingular
X":
:X.,
WIRELESS
7150 Standard Dr.
Hanover, MD 21076
PROJECT NO: 1087.015
DESIGNER: K.H.
ENGINEER: H.M.
SCALE:
0 122 1
GRAPHIC SCALE IN INCHES
HUNTING RIDGE
1234
156 NORTHWESTERN PIKE
WINCHESTER, V 2 3
TITLE:
TITLE SHEET
SHEET NUMBER:
T-1
9
\ f/
(p en rex
communication services, ini
1575 Eye Street, N.W. Suite 350
WASHINGTON, D.C. 20005
PHONE: (202)408-0960
FAX: (202)408-0961
SUBMITTALS
DATE DESCRIPTION REV.
05-20-05 ZONING
I SEAL:
...........
. . . . . cingular
. . . . . . . . . . . . . . . . . . . . . . . . . . :'.... . . . . . WIRELESS
7150 Standard Dr.
Hanover, IVID 21076
PROJECT NO: 1087.015
DESIGNER: TIVIF
ENGINEER: H.M.
SCALE:
I �2 1
� �Fmmll
GRAPHIC SCALE IN INCHES
HUNTING RIDGE
1234
4156 NORTHWESTERN PIKE
WINCHESTER, VA 22603
TITLE
SITE PLAN
40-A-1 53
SHEET NUMBER:
C-1
GENERAL NOTES
1. THE PLANS SHOW SOME SUBSURFACE STRUCTURES, ABOVEGROUND STRUCTURES AND/OR OTHER FEATURES FROM FIELD MEASUREMENTS OR
RECORD MAPPING, EXACT LOCATION OF WHICH MAY VARY FROM THE LOCATIONS INDICATED. IN PARTICULAR THE CONTRACTOR IS WARNED THAT
THE EXACT LOCATION OF SUCH EXISTING FEATURES IN THE AREA MAY BE DIFFERENT FROM THAT SHOWN OR MAY NOT BE SHOWN, AND IT
SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROCEED WITH GREAT CARE IN EXECUTING ANY WORK. 48 HOURS BEFORE YOU DIG, DRILL OR
BLAST, CALL MISS UTILITY FOR THE MARKING OF EXISTING UTILITY LOCATIONS,
2. THE ENGINEER SHALL BE NOTIFIED IN WRITING OF ANY CONDITIONS THAT VARY FROM THOSE SHOWN ON THE PLANS. THE CONTRACTOR'S
WORK SHALL NOT VARY FROM THE PLANS WITHOUT THE EXPRESSED APPROVAL OF THE ENGINEER.
3. WORK SHALL COMPLY WITH CURRENT ISSUES OF ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. ALL NECESSARY LICENSES,
CERTIFICATES, ETC., REQUIRED BY AUTHORITIES HAVING JURISDICTION SHALL BE PROCURED AND PAID FOR BY THE CONTRACTOR.
4. ENTREX COMMUNICATION SERVICES (ENTREX) HAS NOT CONDUCTED, NOR DOES IT INTEND TO CONDUCT ANY INVESTIGATION TO DETERMINE
THE PRESENCE OF ANY HAZARDOUS MATERIAL INCLUDING BUT NOT LIMITED TO ASBESTOS AND PCB'S WITHIN THE CONFINES OF THIS PROJECT.
ENTREX WILL NOT ACCEPT ANY RESPONSIBILITY FOR THE ABATEMENT OR RESULTING CLAIMS FOR DAMAGES OR LOSSES AS A RESULT OF THE
PRESENCE OF HAZARDOUS MATERIALS. IF EVIDENCE OF HAZARDOUS MATERIALS IS DISCOVERED, SUSPEND WORK AS REQUIRED BY GOVERNING
STATUTES, AND NOTIFY CINGULAR WIRELESS. DO NOT PROCEED WITH WORK UNTIL INSTRUCTED BY CINGULAR WIRELESS.
5. ALL MATERIAL FURNISHED UNDER THIS CONTRACT SHALL BE NEW UNLESS NOTED OTHERWISE. ALL WORK SHALL BE GUARANTEED AGAINST
DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF TWELVE MONTHS FOLLOWING SUBSTANTIAL COMPLETION OF PROJECT OR AS
SPECIFIED. THE CONTRACTOR SHALL REPAIR OR REPLACE AT HIS EXPENSE ALL WORK THAT MAY DEVELOP DEFECTS IN MATERIALS OR
WORKMANSHIP WITHIN THE WARRANTY PERIOD.
6. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR ARE TO BE RESPONSIBLE FOR VERIFYING EXISTING SITE CONDITIONS AND DIMENSIONS
AND THE LOCATION OF BURIED UTILITIES AT THE JOB SITE PRIOR TO THE COMMENCEMENT OF WORK. NOTIFICATION MARKING TO BE DONE BY
MISS UTILITY. NO CLAIMS FOR EXTRA COMPENSATION FOR WORK RESULTING FROM CONFLICTS AND OMISSIONS WHICH COULD HAVE BEEN
DISCOVERED BY FIELD VERIFICATION AND INSPECTION, WHETHER INDICATED ON THE CONTRACT DOCUMENTS OR NOT, WILL BE ENTERTAINED OR
PAID.
7. FOLLOW MANUFACTURERS' PRINTED SPECIFICATIONS AND INSTRUCTIONS EXCEPT WHERE SPECIFIED OR INDICATED ON CONTRACT DOCUMENTS.
COMPLY WITH THE MOST STRINGENT INSTRUCTIONS.
8. THE CONTRACTOR SHALL VERIFY AND COORDINATE SIZE AND LOCATION OF ALL OPENINGS FOR STRUCTURAL MECHANICAL, ELECTRICAL,
PLUMBING. CIVIL OR ARCHITECTURAL WORK.
9. THE CONTRACTOR SHALL VERIFY THAT THERE ARE NO CONFLICTS AMONG THE LOCATIONS OF ANY MECHANICAL, ELECTRICAL, PLUMBING, OR
STRUCTURAL ELEMENTS, AND THAT ALL REQUIRED CLEARANCES AND CONSTRUCTION TOLERANCES FOR INSTALLATION AND MAINTENANCE ARE
PROVIDED. N011FY VELOCITEL OF ANY CONFLICTS. VELOCITEL RESERVES THE RIGHT TO MAKE MINOR MODIFICATIONS TO THE DESIGN WITHOUT
ALTERING THE CONTRACT PRICE.
10. DO NOT SCALE DRAWINGS. DIMENSIONS ARE EITHER TO THE FACE OF FINISHED ELEMENTS OR TO THE CENTER LINE OF ELEMENTS, UNLESS
NOTED OTHERWISE. CRITICAL DIMENSIONS SHALL BE CONFIRMED WITH SITE MEASUREMENTS. VERIFY WITH VELOCITEL AS APPLICABLE.
11. THE CONTRACTOR IS RESPONSIBLE FOR DAILY CLEAN UP OF SITE AND REMOVAL AND DISPOSAL OF ALL CONSTRUCTION DEBRIS. AT THE
COMPLETION OF THE PROJECT THE CONTRACTOR SHALL THOROUGHLY CLEAN THE BUILDING SITE AND ANY OTHER SURROUNDING AREAS TO THE
SATISFACTION OF CINGULAR WIRELESS.
12. THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE,
BREAKAGE, COLLAPSE, ETC., ACCORDING TO APPLICABLE CODES. STANDARDS AND GOOD CONSTRUCTION PRACTICES.
13. ALL WORK SHALL BE DONE IN STRICT COMPLIANCE WITH ALL APPUCABLE NATIONAL, STATE AND LOCAL CODES, STANDARDS, ORDINANCES,
RULES AND REGULATIONS.
14. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR DAMAGES TO THE EXISTING FACILITY AND INSTALLATIONS RESULTING FROM
CONSTRUCTION AND GENERAL NEGLIGENCE. REPAIR ALL DAMAGES AND RESTORE FACILITY AND INSTALLATIONS TO THE SATISFACTION OF
CINGULAR WIRELESS AND LANDLORD AT NO EXTRA CHARGE. NOTIFY CINGULAR WIRELESS AND TOWER OWNER OF ANY SUCH DAMAGES PROMPTLY.
REPAIR TO 100% SATISFACTION IMMEDIATELY.
15, WHERE ONE DETAIL IS SHOWN FOR ONE CONDITION, UNLESS NOTED OTHERWISE, IT SHALL APPLY FOR ALL LIKE OR SIMILAR CONDITIONS,
EVEN THOUGH NOT SPECIFICALLY MARKED ON THE DRAWINGS.
16. WHERE NEW PAVING, CONCRETE SIDEWALKS, OR PATHS MEET EXISTING CONSTRUCTION, THE CONTRACTOR SHALL MATCH THE EXISTING PITCH,
GRADE, AND ELEVATION TO MAINTAIN CONTINUITY, AND A SMOOTH TRANSITION.
17. CINGULAR REPRESENTATIVE IS RESPONSIBLE FOR APPLYING FOR COMMERCIAL POWER CONNECTION, CONTRACTOR IS RESPONSIBLE FOR
COORDINATION OF UTILITY INSPECTIONS AND POWER COMPANY INSTALLATION. THE GENERAL CONTRACTOR IS REQUIRED TO KEEP ALL
DOCUMENTATION RECEIVED FROM THE POWER COMPANY. WRITTEN AND VERBAL DISCUSSIONS WITH THE POWER COMPANY, ETC.
18. CONTRACTOR WILL PROVIDE TEMPORARY POWER FOR CONSTRUCTION. GENERAL CONTRACTOR AND HIS SUBCONTRACTORS ARE NOT ALLOWED
TO CONNECT TO ANY EXISTING UTILITIES ON THE SITE.
19. DRAWINGS FORMING THIS SET ARE COMPLIMENTARY AND MUST BE READ AS ONE TOTAL DOCUMENT. DRAWINGS AND SPECIFICATIONS ARE
THE PROPERTY OF CINGULAR WIRELESS. THESE DRAWINGS WERE PREPARED TO BE SUBMITTED TO GOVERNMENTAL BUILDING AUTHORITIES FOR
REVIEW FOR COMPLIANCE WITH APPLICABLE CODES. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO EXECUTE CONSTRUCTION
INDICATED HEREIN ACCORDING TO APPLICABLE BUILDING CODES.
20. IF THE CONTRACTOR OR SUBCONTRACTOR FINDS IT NECESSARY TO DEVIATE FROM ORIGINAL APPROVED PLANS, IT IS THE CONTRACTOR'S
AND THE SUBCONTRACTOR'S RESPONSIBILITY TO PROVIDE VELOCITEL THE PROPOSED CHANGES FOR VELOCITEL AND CINGULAR WIRELESS TO
REVIEW AND APPROVE PRIOR TO PROCEEDING WITH SUCH CHANGES. IN ADDITION, THE CONTRACTOR AND SUBCONTRACTORS SHALL BE
RESPONSIBLE FOR PROCURING ALL NECESSARY APPROVALS FROM THE BUILDING AUTHORITIES FOR THE PROPOSED CHANGES PRIOR TO
PROCEEDING WTH THE REVISED WORK. THE CONTRACTOR AND SUBCONTRACTORS ARE RESPONSIBLE FOR PROCURING ALL NECESSARY
INSPECTIONS AND APPROVALS FROM BUILDING AUTHORITIES DURING THE EXECUTION OF THE WORK,
21. THESE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS SHALL BE INTERPRETED TO BE A MINIMUM ACCEPTABLE STANDARD FOR
CONSTRUCTION. THESE DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR, SUBCONTRACTOR, AND/OR SUPPLIER/MANUFACTURER FROM
PROVIDING A COMPLETE AND CORRECT INSTALLATION SHOULD ADDITIONAL ITEMS AND DETAILS BE REQUIRED FOR PROPER AND SAFE
INSTALLATION.
22. THESE CONTRACT DOCUMENTS AND SPECIFICATIONS DO NOT CREATE A CONTRACTUAL RELATIONSHIP OF ANY KIND BETWEEN VELOCITEL AND
THE CONTRACTOR.
23. THE SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, AND LABOR DEEMED NECESSARY TO COMPLETE THE
WORK/PROJECT DESCRIBED HEREIN.
24, THE CONTRACTOR SHALL OBTAIN AUTHORIZATION FROM VELOCITEL (THE CINCULAR REPRESENTATIVE) TO PROCEED WITH CONSTRUCTION
PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS.
25. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR
ALL THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK
UNDER CONTRACT.
26. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT AND MAINTAIN EXISTING CONDITIONS, EASEMENTS, PAVEMENTS,
CURBING, ETC. DURING CONSTRUCTION, UPON COMPLETION OF WORK, THE CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE
OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY.
27. THE CONTRACTOR SHALL MAINTAIN ALL TRAFFIC IN ALL AREAS IN ACCORDANCE WITH THE VIRGINIA DOT STANDARDS FOR TRAFFIC
CONTROL.
28. THE CONTRACTOR SHALL NOTIFY THE CINCULAR REPRESENTATIVE WHERE A CONFLICT OCCURS ON ANY OF THE CONTRACT DOCUMENTS. THE
CONTRACTOR IS NOT TO ORDER MATERIAL OR CONSTRUCT ANY PORTION OF THE WORK THAT IS IN CONFLICT UNTIL IT IS RESOLVED BY THE
CINGULAR REPRESENTATIVE.
29. CONTRACTOR TO SCHEDULE AND COORDINATE WITH CINGULAR VENDOR, A 3RD PARTY INSPECTION FOR FOUNDATION, SWEEP TEST, AND
ANTENNA ORIENTATION.
EXISTING ICEBRIDGE
EXIT
MD
EQUIPMENT LOCATION PLAN
SCALE: 1 /4"=1'-O"
FREDERICK COUNTY
APPROVAL BLOCK
ZONING ADMINISTRATOR DATE
(GAINESBORO MAGISTERIAL DISTRICT,
FREDERICK COUNTY, VIRGINIA)
TRUE NORTH
I
c9 entrex
communication services, it
1575 Eye Street, N.W. Suite 350
WASHINGTON, D.C. 20005
PHONE: (202)408-0960
FAX: (202)408-0961
SUBMITTALS
DATE DESCRIPTION REV.
05-20-05 ZONING
SEAL:
ci n u lar
..........
g
WIRELESS
7150 Standard Dr.
Hanover, MD 21076
PROJECT NO: 1087.015
DESIGNER: K.H.
ENGINEER: H.M.
SCALE:
0 12 1
■� �
GRAPHIC SCALE IN INCHES
HUNTING RIDGE
1234
4156 NORTHWESTERN PIKE
WINCHESTER, VA 22603
TI TLE:
COMPOUND LAYOUT
PLAN AND
GENERAL NOTES
SHEET NUMBER:
Z-1
PROPOSED CINGULAR AN]
(6 PRESENT/3 FUTURE)`.
AZIMUTH (0', 120% 240')
EXISTING
r-VIC`TIAIrl /lr1Al AAITCAIMAC'
MONOPOLE ELEVATION 1
SCALE: 3/32"=1'-0)' Z-2
(GAINESBORO MAGISTERIAL DISTRICT,
FREDERICK COUNTY, VIRGINIA)
\ I/
(p entrex
communication services, it
1575 Eye Street, N.W. Suite 350
WASHINGTON, D.C. 20005
PHONE: (202)408-0960
FAX: (202)408-0961
SUBMITTALS
DATE DESCRIPTION REV.
11-08-04 85% CONSTRUCTION
11-29-04 90% CONSTRUCTION
SEAL:
cin ular
. . . . . . .WIRELESS
7150 Standard Dr.
Hanover, MD 21076
PROJECT NO: 1087.015
DESIGNER: K.H.
ENGINEER: H.M.
SCALE:
0 1 2 1
GRAPHIC SCALE IN INCHES
HUNTING RIDGE
1234
4156 NORTHWESTERN PIKE
WINCHESTER, VA 22603
TITLE:
MONOPOLE
ELEVATION
SHEET NUMBER:
Z-2
GENERAL NOTES:
1) OTHER EASEMENTS, IF ANY, NOT SHOWN.
NO TITLE REPORT FURNISHED.
2) THIS PARCEL IS NOT IN A F.E.M.A. FLOOD
HAZARD ZONE "A" OR "B'.
3) LEASE PARCEL DERIVED FROM A FIELD SURVEY
AND DEEDS AND PLATS OF RECORD AS FOUND
AMONG THE LAND RECORDS OF FREDERICK
COUNTY, VIRGINIA.
4) THIS PLAN WAS CREATED FROM THE ABOVE DEED
BOOK REFERENCES AND FROM FREDERICK COUNTY
TAX OFFICE INFORMATION.
ELEV. 840 ±
ELEV. TAKEN FROM
STEPHENSON VA.
QUAD SHEET.
ELEV. 1020' ±
POLE DETAIL
NO SCALE
OWNER:
CALVIN L. AND LILLIE J. RITTER
152 LINDEN DRIVE
WINCHESTER, VIRGINIA 22603
PH. (540) 662-1573
DEVELOPER:
CFW INTELOS
1150 SHENANDOAH VILLAGE DRIVE
WAYNESBORO, VIRGINIA 22980
PH 540 946-1895
;FINAL SITE A LAI
APPROVED
FREDERICK COUNTY
APPROVAL BLOCK
/CFO
ZONING ADMINISTRATOR DATE
NOTE: THIS SITE PLAN WILL BE VALID FOR A PERIOD OF
FIVE (5) YEARS FROM THE DATE OF APPROVAL.
TAX MAP 40 ((A)) 154
KEITH J. & MICHELLE D. DAVIS
D.B. 729 PG. 358
ZONED RA
TAX MAP 40 ((A)) 153 LAND USE 2
CALVIN L. & LILLIE J. RITTER
D.B. 388 PG. 160
ZONED RA
LAND USE 2
TAX MAP 40 ((A)) 152 k��
CALVIN L. & LILLIE H. RITTER 7
D.B. 713 PG. 209 A
ZONED RA
LAND USE 2
OG
TAX MAP 40, ((A)) 151
CALVIN L. &; LILLIE H. RITTER \
D.B. 713 PG. 209
ZONED RA SO
LAND USE 2 \
RE: CUP#22-99 of VA PCS Alliance; CFW Intelos, P.I.N. 40—A-148
Conditional Use Permit, #22-99 for a 180 foot monopole
Commercial Telecommunication Facility, has been approved
with a waiver of setback requirement and with the following conditions:
1. All Zoning Ordinance requirements and review agency
comments shall be addressed and complied with
at all times.
2. The tower shall be available for locating personal
wireless service providers.
3. A minor site plan is approved by the County.
4. The tower shall be removed by the applicant or
landowner within twelve (12) months of the
abandonment of operation.
■
1=11M
—
Ell
N60'00'35
159.12"
TAX MAP 40 ((A)) 150
RAYMOND S. &
BETTY L. KERNS
ZONED RA
LAND USE 2
AN89*\
49'15"E
33.71'
y69'55'2�"E 717
42.79
TAX MAP 40 ((A)) 153
CALVIN L. & LILLIE J. RITTER
� D.B. 388 PG. 160
ZONED RA
LAND USE 2
12' INGRESS/EGRESS
t4'04"E EASEMENT
59.16'
S33'17'25"E
119.15'
S38'01'36"E
134.84'
N49'22 28 E S40'37'32"E
50.00' 50.00'
N40'37'32"W LEASE PARCEL
50.00' / 2,500 SQ. FT.
S49'22'28"W SITE — WN 203
50.00' ROADWAY/GAP RUN
\60, %
,SFT
6
�oO Tv
TAX MAP 40 ((A)) 149
PICKY LEE KERNS
D.B. 69�O PG. 68
ZONED RA
LAND USE 2
PROJECT:
'SITE PLAN
SITE - WN 203
FOR
CFW WIRELESS
GANESBORO MAGISTERIAL DISTRICT
FREDERICK COUNTY, VIRGINIA
TAX MAP 40 ((A)) 164
NONNIE F. & THEODORE L. COX
D.B. 449 PG. 407
ZONED RA
LAND USE 5
TAX MAP 40 ((A)) 145
EVERETT & LILLIAN R.
KIBLER
D.B. 351 PG. 420
ZONED RA
LAND USE 2
TAX MAP 40 ((A)) 147
JEFFREI' W. & APRIL E.
WHITACRE
D.B. 852 PG. 1022
ZONED RA
LAND USE 2
GRAPHIC SCALE
200 0 100 200 400
(INS')
1 inch - 200 tL
moo
A PORTION
OF THE LANDS OF
CALVIN L. AND LILLIE H. RITTER
TO BE LEASED BY CFW WIRELESS
EVA
SETBACK TABLE
FN
TOWER
SITE/
LOCATION MAP
SCALE 1 = 2000
HEIGHT OF TOWER = 180'
MAX. HEIGHT = 35'
APPLICABLE SETBACK FOR CERTAIN STRUCTURES
THAT EXCEED 35' IN HEIGHT — 1' PER 1' OF HEIGHT OVER 35'
(180'-35') X 1' ADDITIONAL SETBACK = 145' ADDITIONAL SETBACK
REQUIRED SETBACKS — RA (RURAL AREA) DISTRICT
50' FROM PROPERTY LINES (ADJOINING PROP.— VACANT OR RESIDENTIAL)
100' FROM PROPERTY LINES (ADJOINING PROP.— AGRICULTURAL)
200' FROM PROPERTY LINES (ADJOINING PROP.— ORCHARD)
60' FROM ALL RIGHT OF WAYS
TOWER SETBACK (PRE —WAIVER): 195' FROM PROPERTY LINES
205' FROM RIGHT OF WAY
TAX MAP 40 ((A)) 153
CALVIN L. & LILLIE J. RITTER
D.B. 388 PG. 160
ZONED RA
LAND USE 2
�o\
h
50' X 50' TOWER SITE
NEAREST
PROPERTY
LINE
TAX MAP 40 ((A)) 149
RICKY LEE KERNS
D.B. 690 PG. 68
ZONED RA
LAND USE 2
� 95'�owet
10ggtbock
REPEATER W/PWR
SPLITTER
CHAIN LINK FENCE
W/ BARBED WIRE
LEASE PARCEL DETAIL_
SCALE: 1" = 30'
Offices:
Chantilly,Ve.
Bridgewater,Va.
Pi I I -RA Leesburg,Va.
Virginia Beach,Va.
Patton Harris Rust&Associates,pc Winchester,Va.
Engineers,Surveyors,Planners,t.andscape Architects
116 N. Main Street
Bridgewater, Virginia 22812
540--828-2616
5' DIA. POLE FOUNDATION
SET IN CENTER OF AN
18.5' X 18.5' CONC. PAD
(SEE POLE DETAIL)
SURVEY
DATE
PHR&A
NOVEMBER, 1999
DESIGN
DRAWN
N/A
BHW
CHKD.
SCALE
GAJ
AS SHOWN
FILE No.
SHEET OF
10419-16B