HomeMy WebLinkAbout33-00 Kraft Foods - Flammable Storage Warehouse - Stonewall - Backfile (2)N PROJECT LOCATION J�,<✓.� FREDERICK COUNTY 1 J r r v � I I i L VIRG IN IA -- ®w11*�TIE IE�IELCOPI�I�$o IF®®DS 220 Park Center Drive Winchester, VA 22603 Phone: (540) 678-0442 I F,LAMMABLE STORAG-15 WAREHOUSMS F R '' D R I C i COUNTY, VIRGINIA D E X " F I!j -I N A W I N G S- DESCRIPTION DRAWING NO. COVERSHEET..................................................................C-1 NOTES AND LEGEND ....................................................... C - 2 1EXISTING SITE CONDITIONS...........................................C-3 SITEPLAN........................................................................0 - 4 APPROVED S;tom PIS 33.00 �W'�I'TH O� v HOOD D. MOOD ;0- Naama '0,� 191 v�. y Z000 ORAL PROFESSIONAL SEAL VICINITY MAP 1 " = 2000' Rev. 07/19/2000 Approved by the Zoning Administrator Zoning Administrator Signature t /0-0 Date Note: Site plan is valid until 5 years after approval date. Zw::91 EP ENGINEERING, 971 Acorn Drive Harrisonburg, VA 22802 Phone (540) 434-4135 INC. C ® 042 GENERAL NOTES 1. Contractor shall furnish all materials, labor and equipment required and shall perform all work including restoration for the completed installation of utility systems and all other improvements shown or implied as necessary. Unless otherwise noted, specifications for all work will be in accordance with the applicable Standards and Contract Specifications of the Virginia Department of Transportation. Virginia Department of Health. County of Frederick, and the contract documents. 2. Any discrepencies found between the drawings and specifications. and site conditions or any inconsistencies or ambiguities in drawings or specifications shall be immediately reported to the engineer in writing, who shall promptly address such inconsistencies or ambiguities in writing. Work done by the contractor after his discovery of such discrepancies. inconsistencies or ambiguities, without clarification from the engineer of record, shall be done at the contractor's risk. 3. Contractor to verify the exact location of all existing utilities and notify the Engineer of any conflicts with existing and proposed utilities. Damage to existing utilities shall be the Contractor's responsibility. Forty-eight (48) hours prior to any excavation call "Miss Utility" 1-800-552-7001. 4. Contractor shall be responsible for all construction stakeout. All dimensions and elevations shown on the contract documents shall be field verified by the Contractor prior to beginning work. 5. Contractor shall obtain, at his expense, all permits required prior to starting work and shall adhere to the conditions imposed. 6. Any unusual subsurface conditions encountered during the course of the work shall be brought to the attention of the Geotechnicul Engineer / Owner. 7. Access by emergency vehicles must be maintained at all times. Access to fire hydrants must not be impeded at any time by parked cars, construction materials, soil stockpiles. etc. 8. Refer to architectural drawings for exact building dimensions. CONSTRUCTION NOTES EARTHWORK NOTES: 1. All materials used for fill or back -fill shall be free of wood, roots, rocks, boulders or any other non -compactible soil type material. Unsatisfactory materials also include man-made fills and refuse debris derived from any source. 2. Satisfactory material for use as fill for public streets includ,:;") materials classified in ASTM D-2487 as GW, GP, GM, GC, SW, SP, SM, SC. ML and CL groups. The moisture content shall be controlled within plus or minus 2 percentage points of optimum to facilitate compaction. Generally, unsatisfactory materials include materials classified in ASTM D-2487 as PT, CH. MH. OL, OH, and any soil too wet to facilitate compaction. CH and MH soils may be used subject to results of the Geotechnical Report and upon approval from VDOT. Soils shall have a minimum dry density of 92 lb/cu. ft. per ASTM D-698 and shall have a plasticity index less than 17. 3. Materials used to construct embankments for any purpose, back -fill around drainage structures or in utility trenches or any other depression requiring fill or back -fill shall be compacted to 95% of maximum density as determined by the standard proctor test as set out in ASTM Standard D-698. The contractor shall, prior to any operations involving filling or back -filling, submit the results of the proctor test together with a certification that the soil tested is representative of the materials to be used on the project. Tests shall be conducted by a certified materials testing laboratory and the certifications made by a licensed professional engineer representing the laboratory. 4. Compaction of fill material under building slabs shall be based upon recommendations of soils engineer after completion of standard proctor test and shall meet bearing requirements of architect for buildings. The contractor shall be responsible for testing. 5. Embankment fill and trench back -fill shall be placed in lifts at a maximum uncompacted depth of 8 inches and 6 inches. respectively. Density tests shall be conducted at the following minimum frequencies: (a) embankments for roads, streets, dams, etc.: one test per lift per 10,000 square feet of lift. (b) back -fill around structures and in trenches: one test per lift per 500 linear feet of trench. 6. Changes or revisions to these construction plans shall not be made without approval by the owner, engineer and all regulatory agencies. SITE PLAN NOTES: I. Parcel area: MOO acres 2. Zonl ng: M-1 J. Use: Manufacturing 4. Property Identl f I cotl on *: 54 ((A)) 36H and 36G 5. Maglsterlai Dlstrlct. Stonewall 6. BuIlding Setbacks: Front= 75' Slde= 251 Rear= 25' 7. BuNding Area= Proposed: 9,371 sq. ft. (Per SJte Development Plan *50-99) Proposed: 8,727 sq. ft. (per Slte Development Plan *52-99) Proposed: 2,312 sq. ft. (per Slte Development Plan *54-99) Proposed: 2,560 sq. ft. (per SJte Development Plan *14-00) Proposed: 7,520 sq. ft. (per Slte Development Plan *21-00) Proposed: 720 sq. ft. (per this plan) Exlsting: 219,298 sq. ft. 8. F.A.R.= 9,371 sq. ft. (per Slte Development Plan *50-99) + 8,727 sq. ft. (per SI to Development Plan *52-99) + 2,312 sq. ft (per SJte Development Plan *54-99) + 2,560 sq. ft. (per Slte Development Plan *14-00) + 7,520 sq. ft. (per SI to Development Plan *21-00) + 720 sq. ft. (per thls plan) + 219,298 (exlsting)/30.00 acresx43,560 sq. ft. =250,508/1,306,800=OJ92 ABBREVIATIONS C/L OR CENTERLINE CONC. CONCRETE DIA. DIAMETER EG EXISTING GAS EL. ELEVATION ESMT. EASEMENT EW EXISTING WATER EX. EXISTING F.E. FOUNDATION ELEVATION F.E.S. FLARED END SECTION F.H. or F/HYD FIRE HYDRANT FL FIRE LINE F.W. TOP OF FOUNDATION WALL G.V. GATE VALVE HORIZ. HORIZONTAL INV. INVERT LAT. LATERAL LT. LEFT M/H MANHOLE MIN. MINIMUM NE NORTH EAST NW NORTH WEST P.C. POINT OF CURVE P.I. POINT OF INTERSECTOPN P.T. POINT OF TANGENT PVC POINT OF VERTICAL CURVE PVI POINT OF VERTICAL INTERSECTION PVT POINT OF VERTICAL TANGENT R RADIUS R.D. ROOF DRAIN RT. RIGHT SAN. SEW. or S SANITARY SEWER SEW. SEWER ST'D STANDARD STM. SEW. STORM SEWER SE SOUTH EAST SW SOUTH WEST TPD TRIPS PER DAY VERT. VERTICAL W/L WATERLINE X-ING CROSSING EXISTING —X X PROPOSED ROADS ------------ I ROAD CENTERLINE CURB CURB TAPER • SIDEWALKS BUILDINGS FENCE Aft DECIDUOUS TREE CONIFEROUS TREE CONIFEROUS SHRUB PROPERTY LINE C__===='= STORM SEWER — — 2900 — - -----2898---- 2876.3 Iesk:)o INDEX CONTOUR ease INTERMEDIATE CONTOUR �C SPOT ELEVATION 2893.66� ------------ LIMITS OF CLEARING AND/OR GRADING PARK//VG ANALYS/S PARKING SPACES REQUIRED FOR WAREHOUSE SPACE PER THE FREDER/CK COUNTY ZONING ORDINANCE IS AS FOLLOWS: I PARKING SPACE PER WAREHOUSE EMPLOYEE IS REQUIRED. (NO ADDITIONAL EMPLOYEES WILL BE UTILIZED IN CONJUNCTION WITH THIS WAREHOUSE ADDITION.) THERE IS NO ADDITIONAL PARKING REQUIRED FOR THIS BUILDING ADDITION. FLOOR AREAS EXISTING MANUFACTURING - 209,026 SQ. FT. PROPOSED MANUFACTURING (PER SITE DEVELOPMENT PLAN 4P.52-99) - (+/-)8,727 SO. FT. PROPOSED MANUFACTURING (PER SITE . DEVELOPMENT PLAN 1054-99) - <+/->2,3/2 SQ. FT. EXISTING OFFICE SPACE - (-/-)I0.272 SQ. FT. PROPOSED OFFICE SPACE (PER SITE DEVELOPMENT PLAN 4050-99) SQ. FT. PROPOSED WAREHOUSE EXPANSION (PER SITE DEVELOPMENT PLAN 4"I4-00) - (•/-)2,560 SQ. FT. PROPOSED FLA"MABLE STORAGE WAREHOUSE (PER THIS PLAN) - (-/-)720 SQ. FT. GROSS FLOOR AREA - <+/-)242,988 SO. FT. PROPOSED OUTDOOR EMPLOYEE BREAK AREA (PER SITE DEVELOPMENT PLAN 4050-99) SO. FT. PROPOSED RAIL SHED ADDITION (PER SITE DEVELOPMENT PLAN w 2/-00) - (;/-)7,520 SQ. FT. TOTAL FLOOR AREA - (+/-) 25I,842 SQ. FT . L TRIAD ENGINEERING, INC. HARRISONBURG. VIRGINIA 7v g o >� r rn w N O o U N N O U N p O L C o U 2 O z o v= o 0 0 0 � U (n ; Y v+ Q ° a �n p U U Z w a Z ry t3a LLJ o W 0l? CL Z d W U W Z yob W J v ul WFt in Ln 0 Q Ao v MWnRo l N.«>=1 ti ONAL PROFESSIONAL SEAL LLJ 0z Z W 0 LAJ QW (Al Q 0 0 w LLI 0 W 0 <� 0 o O Z I- �— Q L Q V) Y M LLJ LLI < 0 �(/��� LLI WO.I < LL J L Drawing Number: C-2 C I 1 I I =:q1 L TRIAD ENGINEERING, INC. RETAIL ZONED B-3 ,� I 54 ((A) ) 84 ------------------------------- --- --- --------- -- ------—----------- --- -- - 1------- n II 1 RETAIL ZONED M-2 43 ((A)) 35 1 1 1 ------------------------------------------------ 11 INTX. R.R= 1' STA. --------------------------------------------------------------------_H_-— —------------'-�- ►J +� \---------------------------- N 47 227 23r'-E 80170--------------------------------------------------------------------------------------------------------------------------------------- ----- Lj -------�5�B117CDTRC$E?87CCR---------1------------------*-------------- �•'•y�-------------- ---� BUILDING SETBACK • I i PLANT - NORTH I � PROPOSED RAIL \ — 1— — — — — • . I i ' , SIDING RELOCAT/ON n .' y • I I ; , AND ADO/T/0/V 11 : , I ► I a 'I REEF_ R TO KRAFT FOODS pCHILLER DIKERAIL SIDING RELOCAT/O NO EXP NS/ON I PAD FRUCTOSE ORAW/NGS BY TR/A INC. dI TANKS �I 9RESIN SILO OATEO /0-27—/9. EVISEO" 05—/6—�000. I1 PAD SPIL BASIN APPROV O BY CS Y I I I �-- P9 -�------------ �_ -- r— M----�iH---- i i I � i � � � � � � � i � �r•4--I I-� 1 I ; 1 --------------- II II l_ - - - -- 1 � ---- 1L-------_-_-_-_ - -_1-I--L-_1-_��-1-I--I--I--��-- ------------------ --- - __ _ _____ I 1 II p r I -I� T----- - Ifj- ItII------�- ----C�-r=. . . . �-1=1-T r2 T_C=L --------- ----- - 1 —E �-� � ---- �-t-I---1-1--I-rt 'i r-I-Y-t--1-t-t--1- I I �l'fi--- �i Tip I-r-1-7-r-1-rG-r-I-_-T--1-T_r — ------ ~ii—� — I i 1 I I I I I I I IJI I I I I I II I I I I \ I I I� FT I I p I( oil I I I, 43 ((A)) 36 I II — J , , I Zw.�„ Fo1i HISPLAN SI �-�EET SITE ORIENT AT ION -ONLY= VACANT ZONED M-1 54 ((A)) 36G (OWNED BY KRAFT GENERAL FOODS) PROPOSED BUILDING AOOIT/ON. REFER TO S/TE DEVELOPMENT PLAN '"/4-00 / RETAIL / ZONED B-3 / 54 ((A)) 85 -------------------------------------------------------------------- -- -- ------ / --- PF?OPOSED RA/LHOAO S"ED. REFER TO S/TE DEVELOPMENT /=LAN '"2/-00 - — -- — -- — -- — -- - -- / ------------------------------------------ VACANT ZONED B-3 43 ((1) C - 1I _+ II I ----• I I TO SITE OF_VELOPMENT I �------�-------�---- - I I I 1 1 j !(D I , PLAN 4*50-99 I---�---- --- I--------i---- -- —I I I '' ,o I 1 11 I I I 1 II I I I I II I I I I I ; I{--- --- ;-------�--------;---- --iCl MANUFACTURING. STORAGE AND OFFICE BUILDING I I N 4} I I I I N PP II I FLOOR ELEV.--690.0 I I III �A II I I I BUILDING HEIGHT-LESS 5 THAN AREA=219,298SOT MANUFACTURING --I ZONED M-11 LL----- 1 - II r I I 54 ((A)) 36H I 1 j----------- ' (A+ m I I \It ---�---- --- 4-------�---- -- - ,I I my m I I I I I i 1 iI I I II U-----,---- -�---- -�---- -- - I mM I t i t I II I u--- PROPOSED FLAMMABLE �►t * I I N I ; ; �' I I I � 1.1 I STORAGE WAREHOUSE — j i (SEE SHEET C-4> o � u--- ,=_ �—= --i► _-- �! I ,I I I LL J I -�------,---- -- - , r I PROPOSED BUILDING o I I -- -a ---- AOO1/T/ON. REFER U.I I I I —� I ► I I J TO S/TE DEVELOPMENT — — — — —I—r3[ `-- I I I I I ! CONDUIT I J J PLAN '"54-99 I I I J J I I I J I 14 --- -- ,-------�-------I---- -- --II � "I I 1; +uu -06 J J I n I I ! fT------J----=---i---- --� --- ==�=II------rt--� I II I13II -4" �I�c� II w 1I In o hN _ III _-__-----------------_r II �lll ' I/'IiI�I JI! I l .d- I II II I I II I I I J I I II li i I II II U 1 T r II I ' I �I I I ! I ZONED TM-1NG I=HO/=OSEO BUI LONG I W I I I' I IJ I 54 ((A)l 36L A00/T/ON. REFER I 11 II 11 n 1 �►�.: �' ' TO S/TE DEVELOPMENT -4I PLAN 4'52-99 I � I I I II � M I 1 I �11=.• II �� � `^I I y I 1 I II I i II 1/ I 1 1 :�: • 11 1 �I I I 1, I 1 1 I I I I It ------j__Bj .LG SETBACK—�— ------- -- ---- —� II---��---0— -- — ----- —— _- I —� • N �— 75' BUILDING SETBACK —�LD.l T1- — �— - -I- - - -- -------------- �-- II 1 I I I I ! I J _ I I I I 1 I R�0:6B°°' ----------------- --------------- S 47• 22' 23" 1 11 WEST BROOKE ROAD (ROUTE 1320) 60' R/W II POSTED SPEED-35 M.P.H. 1 ` EX. 2-4 -," I I 1 1 CONDUIT I I \\ I 1 r-,1-1----------------------- ---- I- I - -- - - - - - - - - - T} ----- ��--------I ( ► , ----------------------- t,-------------------------------- -------------------------------------------------`------------------------------------------------------------------------------------------------------------------------------------------------11-----------------1�----------------------`-7 I /kl VACANTZONED M-154 ((A)) 360 20' SAN. 1 I I SEW. ESM' T. I I I I I Z O o •I— C M O O N O U �} cV O 1 O p O O c U O w U c o 0 U � 0 � (n � Q� p 7) v U I U) a) Q) o Jc o U z V. 0 z Of w w z V z W 0 L`L 1 < <99 ;< =o- C9 � v1 w w 1— to (.5 c3 w x� U 3 M 0 rn {�1,N3,TH op MW D.'410D No,oamm ti 'ORAL V LJ z U) O Q oz z F-- LiJ (' 0 It r/') Q > z o p 0L,JF_ U D:f o LiJ F- oO U F-- o Y Ln Y Jcr- mw Q 0 z G .� Q V I J LL_ _ x L,J Drawing Number IN m C-3 NOTES: IJ MAXIMUM BUILDING HEIGHT FOR ZONING DISTRICT M-1 IS 60' PER SECTION 165-83A OF THE FREDERICK COUNTY ZONING ORDINANCE. THE HEIGHT OF THE PROPOSED BUILDING /S LESS THAN 60'. 2J UTILITY SERVICE TO WAREHOUSE SHALL BE PROVIDED FROM EXISTING BUILDING. NEITHER OVERHEAD NOR UNDERGROUND ELECTRIC SERVICE /S REQUIRED. 3J SEE ARCHITECTURAL/MECHANICAL DRAWINGS FOR THE ROUTING OF UTILITIES WITHIN THE PROPOSED WAREHOUSE. 4J SEE ARCHITECTURAL/STRUCTURAL DRAWINGS FOR FOUNDATION DETAILS AT EXISTING UTILITY CROSSINGS, DOOR LOCATIONS, STOOPS, ETC. 5J THOUGH NOT SPECIFICALLY DEPICTED HEREIN. SCOPE OF WORK FOR THE PROPOSED WAREHOUSE SHALL INCLUDE ALL REQUIRED DEMOLITION. 6J CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF ALL EXISTING UTILITIES PRIOR TO INITIATION OF ANY CONSTRUCTION ACTIVITIES. 7J ROOF RUNOFF SHALL BE CONVEYED AWAY FROM THE BUILDING EXTERIOR VIA DOWNSPOUTS AND SPLASH BLOCKS OR TIED DIRECTLY TO EX/STING STORM DRAINAGE SYSTEM. REFER TO ARCHITECTURAL DRAWINGS BY STAHLMAN ENGINEERING CORPORATION FOR RELOCATION OF EXISTING SCUPPER DRAINS AND LOCATION OF PROPOSED SCUPPER DRAINS. existing son. m/h top=685.79 4" inv. in=679.29 exist. 6" inv. in=678.84 exist. 6" inv. in=679.14 roof drain roof drain 8J BUILDING SETBACK REQUIREMENTS /N ZONING DISTRICT M-/ PER THE FREDERICK COUNTY ZONING ORDINANCE ARE AS FOLLOWS.- -FRONT YARD SETBACK ON PRIMARY OR ARTERIAL HIGHWAYS - 75' -FRONT YARD SETBACK ON COLLECTOR OR MINOR STREETS - 75' -SIDE YARD SETBACK - 25" -REAR YARD SETBACK - 25' 9J BUILDING SETBACKS PROVIDED: -FRONT YARD BUILDING SETBACK PROVIDED TO THE EAST (PARK CENTER DRIVE) - N/A -FRONT YARD BUILDING SETBACK PROVIDED TO THE SOUTH (WEST BROOKE ROAD) - 160J' -SIDE YARD BUILDING SETBACKS PROVIDED TO THE WEST - 1094.6' -REAR YARD SETBACKS TO THE NORTH (CSXT R-O-W) - N/A /OJ ALL SIGNS LOCATED ON THIS PROPERTY SHALL CONFORM WITH THE STANDARDS OF THE FREDERICK COUNTY ZONING ORDINANCE. UJ NO OUTDOOR STORAGE WS PROPOSED WITH THIS WAREHOUSE. 12) THERE ARE NO EXISTING SIGNIFICANT ENVIRONMENTAL FEATURES. 13J ALL OUTDOOR LIGHTING FIXTURES ASSOCIATED WITH THIS BUILDING ADDR-ION ARE SURFACE MOUNTED ON THE FACE OF THE BUILDING. SEE ARCH. PLANS FOR LIGHTING SPECIFICATIONS. OUTDOOR LIGHTING SHALL BE ARRANGED TO DEFLECT GLARE AWAY FROM ADJOINING PROPERTIES AND PUBLIC STREETS. (PER SECTION 165-35A OF THE FREDERICK COUNTY ZONING ORDINANCE). Lf 14J THERE ARE NO PROPOSED EASEMENTS IN ASSOCIATION WITH THE CONSTF'UCT/ON ------------ OR OPERATION OF THIS WAREHOUSE. I I i I I I I5J THE OUTDOOR TRASH RECEPTACLE /S A FULLY ENCLOSED AND SELF-CONTAINED TRASH COMPACTOR WITH ACCESS ONLY FROM THE INTERIOR OF THE BUILDING. THE ENTIRE I cn CONTAINER WILL BE REMOVED AND REPLACED WHEN FULL REMOVE I I I II NG 6' SAN. LAT.Ll G M/H AS NECESSARY (PER SITE DEVELOPMENT I I PLAN 052-99) I ex i st i h g s t m m/ f 1 0 Inv. 0ut=678. 92 I top�688. 77 I existin building line ex. w. v.---- --- -- J I8" inv.i i 84.1 �DI I 1\� ex I st I ng stm m/h \ __`-_--_______-------------------- ,I I, /�' ---------a1--�8 I 11 o inv. ou =684. dg I I , top=685. 94 y�; ___- I ex i st i ng stm rn/h - rl •d II -- - �I I ii I I 01 II 12 inv. i n=680. 75 I �} „ existing stm m,(h top=685. 59;' •' V I ex i st.� - II ' o I� \ 1 2" inv. i n=680. 65 Ir to 685. 68 I r' roof drai n " i 0 ,l II p= I inv. out-683. 03 c� ----- .''ten,-° III \- / I I\ _ I =___ �I I _ s�� I I existing edge ' 1 2" inv. out=680. 56 ` v� ) ----------- -- ----- _ _ _ _----- - -� I=F=====_____ - i 9 g 1 i �IJ -- ------ - - -'-- _ -_------. ----------- --- - - -- - --_• i Ir ��n I •I r to I �- R I U) l of pavement L I II g IIII I - IIII °Io - CONVERTED EX.6'SANITARY _ II'III III existing stm. m/hSEWER TO FLOOR DRAIN FROM ICII ia - - �B- , CAPRI SUN 2" BUILDING ADDITION top =6 8 5.8 9 /8 ' • I'I iv , m (PER WASTEWATER TREATMENT 1 5 inv. . i n =6 7 9. 8 3 ----J</,rr• sf II / / I 10" inv. in=680.29 •,ti ".'Vt.I I III I 11 I BUILDING ADDITION 1I I II ' - ,� y% - - \ 11 / ,° � � � I CHILLER PAD / - "- _ _ _ _ _ _ _ 1 0 inv. i n =6 8 0. 1 6 j o C 1 11 FF.-686.00' _ PLANS, DATED ll-i�-99) 1 5 " inv. out =6 7 7. 51 1 I III - - .•I1•°•. c C I Ir% I • II•o. •. I ----- III &(D i _ (PER ;;SITE DEVELOPMENT _------- " existing stm m/h ;�i� \�'��y -AA--- - -� --i------- -- , .°11 ' I� - ) - _ ------ Ur PLAN 99 'top=685.77 rr �-R------.Iq°.12" inv. in=680.10ilexistin I oIn-------- g I REFER TO ARCHITECTURAL ° I r , --12 inv. out=679.77 1, 11 si lo DWGS FOR EXACT BUILDING DIMENSIONS, EXTERIORDOOR LOCATION, ANDSTAIR/LANDING DETA/LSX�PROPOSED FIRE LANE iIIVex i st i ng ed°', !i I Ali X S/GNAGE AND 6' x 20' .o rt of pavement I co I I II o PAVEMEh r MARKINGS I - ° •. ' I I , 11 AT EXISTING FIRE HYDRANT o0 (EXACT LOCATION TO BE V. ,• i ��'/_ ii / DETERMINED BY THE FIRE •,o I I CAPRI SUN BLOC. AD q/77ON 1'�ex i s I ng edge 11 I MARSHALL) '•' ° �` PROPOSED USE. MANUFACTURING rl of IcIvement 1111 o,i i° F.F.-690.00 I I (PER SITE DEVELO4MENT /' 11 I - - - -- �� . • �.!' ° PLAN #52-99)I II I �-------__-.__---- �-•-DT����rD--x� �rD• `• ..gyp' V,;`•_�..LI:' --------- °. •.°. °. rI -------- 75' BUILDING SETBACK .. ° ° V. . ' p1' -i - 11 ��4 75' BUILDING SETBACK -��----------= ------------, ' -----I- ------ ---- - ---- ex. ------------- - - -- -al------------------------ - - - ' i 'L- - - - - -- a ° I 10" f/I I - 1t --- -------- - - - - -� ll ---� existing fire I 'y, I " --- - -- hydrant �'-"-- " ........... -- --- 111 existing sa m/h --------- �-----------------A1�--10'r-i�p.68�n. 77.74 loll inv. ut 677.68 T___ \\ "Z//-- _y� -1 m^\ ------------------------------------ _ -- - - ------ 1--------- _____________________0 ---------------------------- 1 - ---- - - ------------------------------ x , - - - - - - - - - - - - - - - - - - - - - 60' RIGHT -OF-WAY f }-----------------------------------------------------------------------------_ _ -_ _=--..-------------------------------------------------------------- --- ------ - l ---------------- -------------------------------------------- ---------------------------------------------------- --- ��,'�- \�`------------------------------ _- -60' R/GHT- F-WAY ----------- PLANT NORTH BUILDING OFFICIAL'S NOTES: MR lJ ADDITION SHALL COMPLY WITH THE VIRGIN/A UNIFORM STATEWIDE TRIAD ENGINEERING, INC. BUILDING CODE AND SECTION 307, USE GROUP H (HIGH HAZARD), OF NARRISOW RG VIRGINIA THE BOCA NATIONAL BUILDING CODE - 1996. PLEASE NOTE SECTIONS 507 (UNLIMITED AREA BUILDINGS), TABLE 707J (FIRE WALL AND PARTY WALLS), 904 (FIRE SUPPRESSION SYSTEM) OF BOCA. 2J AT THE TIME OF PERMIT APPLICATION, PLEASE SUBMIT INFORMATION I ABOUF THE AMOUNTS AND TYPES OF FLAMMABLES TO BE STORED. E E 3J ALL PLANS SUBMITTED SHALL BE SEALED BY A LICENSED ARCH/TECT/ENGINEER REGISTERED /N VIRGIN/A. a = O N Q% O Y � U 0 2 I I a PROPOSED RELOCATION OF EXISTING IY x 25' TRASH COMPACTOR (SEE ARCH. PLANS FOR PAD DETAILS) PROPOSED FLAMMABLE STORAGE WAREHOUSE approximate (720 SO,FTJ location of FF.-690.00 existing dumpsters exist. roof drain existing son. m/h top=688.90 6" inv. in=684.45 6" inv. out=683.81 . c o O O N O U 0 C 0 0 U U M ca 7 Q) o 0 U V) T � o � p U U Z N 0 Q fi4�LTH 01p, -) TODD n WOOD �s No. oaaa PROFESSIONAL. SEAL Ld V) 0Z W 0 Q > O �- QW� LL_ Q � �0 I- 00 U < V) YWaf Q C) �Of Q �- J L� z Q 0- W V) Drawing Number: C-4 N PROJECT LOCATION FREDERICK COUffrY J^> ' < ✓ / / r —�a I J \ V I R G IN I A C)WTlT E� DE�EL®PE�v 220 Park Center Drive Winchester, VA 22603 Phone: (.540) 678-0442 F,LAMMABL.E' FR D R'ICK COUNTY, ii.Tli�►■ ('F D�2AWINGS DESCRIPTION DRAWING NO. COVER SHEET..................................................................C-1 NOTES AND LEGEND.......................................................0 - 2 EXISTING SITE CONDITIONS .......................................... C-3 SITEPLAN..................................................._....................0 - 4 y�q' • ,erg. Fi A �; r''sj, _:.D Q Pkt- r # 33 - O o v MDD D. MOOD :0' Naoam 19 -fuL y Z000 �®NAL VICINITY MAP 1" = 2000' Rev. 07/19/2000 Approved by the Zoning Administrator Zoning Administrator Signat re mum Date Note: Site plan is valid until 5 years after approval date. 7171) ENGINEERING, INC. 971 Acorn Drive Harrisonburg, VA 22802 Phone- (540) 434-4135 C ® 042 0IM GENERAL NOTES 1. Contractor shall furnish all materials. labor and equipment required and shall perform all work including restoration for the completed installation of utility systems and all other improvements shown or implied as necessary. Unless otherwise noted, specifications for all work will be in accordance with the applicable Standards and Contract Specifications of the Virginia Department of Transportation. Virginia Department of Health, County of Frederick, and the contract documents. 2. Any discrepencies found between the drawings and specifications, and site conditions or any inconsistencies or ambiguities in drawings or specifications shall be immediately reported to the engineer in writing, who shall promptly address such inconsistencies or ambiguities in writing. Work done by the contractor after his discovery of such discrepancies, inconsistencies or ambiguities, without clarification from the engineer of record, shall be done at the contractor's risk. 3. Contractor to verify the exact location of all existing utilities and notify the Engineer of any conflicts with existing and proposed utilities. Damage to existing utilities shall be the Contractor's responsibility. Forty-eight (48) hours prior to any excavation call "Miss Utility" 1-800-552-7001. 4. Contractor shall be responsible for all construction stakeout. All dimensions and elevations shown on the contract documents shall be field verified by the Contractor prior to beginning work. 5. Contractor shall obtain, at his expense. all permits required prior to starting work and shall adhere to the conditions imposed. 6. Any unusual subsurface conditions encountered during the course of the work shall be brought to the attention of the Geotechnical Engineer / Owner. 7. Access by emergency vehicles must be maintained at all times. Access to fire hydrants must not be impeded at any time by parked cars, construction materials, soil stockpiles. etc. 8. Refer to architectural drawings for exact building dimensions. CONSTRUCTION NOTES EARTHWORK NOTES: 1. All materials used for fill or back -fill shall be free of wood, roots. rocks, boulders or any other non -compactible soil type material. Unsatisfactory materials also include man-made fills and refuse debris derived from any source. 2. Satisfactory material for use as fill for public streets include materials classified in ASTM D-2487 as GW, GP, GM, GC. SW, SP, SM, SC. ML and CL groups. The moisture content shall be controlled within plus or minus 2 percentage points of optimum to facilitate compaction. Generally, unsatisfactory materials include materials classified in ASTM D-2487 as PT, CH, MH, OL, OH, and any soil too wet to facilitate compaction. CH and MH soils may be used subject to results of the Geotechnical Report and upon approval from VDOT. Soils shall have a minimum dry density of 92 lb/cu. ft. per ASTM D-698 and shall have a plasticity index less than 17. 3. Materials used to construct embankments for any purpose, back -fill around drainage structures or in utility trenches or any other depression requiring fill or back -fill shall be compacted to 95% of maximum density as determined by the standard proctor test as set out in ASTM Standard D-698. The contractor shall. prior to any operations involving filling or back -filling, submit the results of the proctor test together with a certification that the soil tested is representative of the materials to be used on the project. Tests shall be conducted by a certified materials testing laboratory and the certifications made by a licensed professional, engineer representing the laboratory. 4. Compaction of fill material under building slabs shall be based upon recommendations of soils engineer after completion of standard proctor test and shall meet bearing requirements of architect for buildings. The contractor shall be responsible for testing. 5. Embankment fill and trench back -fill shall be placed in lifts at a maximum uncompacted depth of 8 inches and 6 inches. respectively. Density tests shall be conducted at the following minimum frequencies: (a) embankments for roads, streets, dams, etc.: one test per lift per 1 0, 000 square feet of I i ft. (b) back -fill around structures and in trenches: one test per lift per 500 linear feet of trench. 6. Changes or revisions to these construction plans shall not be made without approval by the owner, engineer and all regulatory agencies. SITE PLAN NOTES: I. Parcel area: 30.00 acres 2. Zonl ng: M-/ J. Use: Manufacturing 4. Property /dentlflcatlon *: 54 ((A)) 36H and 36G 5. Magisterl a/ Dl strl ct. Stonewall 6. Bul/dI ng Setbacks: Front= 75' Slde= 25' Rear= 25' 7. Bull d I ng Area= Proposed: 9,371 sq. ft. (Per SI to Development Plan *50-99) Proposed: 8,727 sq. ft. (per Slte Development Plan *52-99) Proposed: 2,312 sq. ft. (per Slte Development Plan *54-99) Proposed: 2,560 sq. ft. (per Slte Development Plan *14-00) Proposed: 7,520 sq. ft. (per Slte Development Plan *21-00) Proposed: 720 sq. ft. (per this plan) ExI stI ng: 219,298 sq. ft. 8. F.A.R.= 9,37/ sq. ft. (per Slte Development Plan *50-99) + 8,727 sq. ft. (per Slte Development Plan *52-99) + 2,312 sq. ft (per Slte Development Plan *54-99) + 2,560 sq. ft. (per Site Development Plan *14-00) + 7,520 sq. ft. (per Slte Development Plan *21-00) + 720 sq. ft. (per thls plan) + 219,298 (exlsting)/30.00 acresx43,560 sq. ft. =250,508/1,306,800=OJ92 ABBREVIATIONS C/L OR CL CENTERLINE CONC. CONCRETE DIA. DIAMETER EG EXISTING GAS EL. ELEVATION ESMT. EASEMENT EW EXISTING WATER EX. EXISTING F.E. FOUNDATION ELEVATION F.E.S. FLARED END SECTION F.H. or F/HYD FIRE HYDRANT FL FIRE LINE F.W. TOP OF FOUNDATION WALL G.V. GATE VALVE HORIZ. HORIZONTAL INV. INVERT LAT. LATERAL LT. LEFT M/H MANHOLE MIN. MINIMUM NE NORTH EAST NW NORTH WEST P.C. POINT OF CURVE P.I. POINT OF INTERSECTOPN P.T. POINT OF TANGENT PVC POINT OF VERTICAL CURVE PVI POINT OF VERTICAL INTERSECTION PVT POINT OF VERTICAL TANGENT R RADIUS R.D. ROOF DRAIN RT. RIGHT SAN. SEW. or S SANITARY SEWER SEW. SEWER ST'D STANDARD STM. SEW. STORM SEWER SE SOUTH EAST SW SOUTH WEST TPD TRIPS PER DAY VERT. VERTICAL W/L WATERLINE X-ING CROSSING EXISTING PROPOSED ROADS ------------ •-•-•-•-•-•� ROAD CENTERLINE ______- CURB CURB TAPER ------------- ------------- 7 7 SIDEWALKS BUILDINGS —X X FENCE IAOL DECIDUOUS TREE CONIFEROUS TREE CONIFEROUS SHRUB ----••--•-----•-•• PROPERTY LINE E STORM SEWER — — 2900 — — g-900 INDEX CONTOUR -----2898---- INTERMEDIATE CONTOUR X SPOT ELEVATION 2876.3 ae9.3.se� ------------ LIMITS OF CLEARING AND/OR GRADING P.ARK//VG .ANALYSIS PARKING SPACES REQUIRED FOR WAREHOUSE SPACE PER THE FREDER/CK COUNTY ZONING ORDINANCE /S AS FOLLOWS: I PARK/ NG SPACE PER WAREHOUSE EMPLOYEE /S REQUIRED. (NO ADDITIONAL EMPLOYEES WILL BE UTILIZED IN CONJUNCTION WITH THIS WAREHOUSE ADDITION.) THERE IS NO ADDITIONAL PARKING REQUIRED FOR THIS BUILDING ADDITION. FLOOR AREAS EXISTING MANUFACTURING - (+/-> 209,026 SQ. FT. PROPOSED MANUFACTURING (PER SITE DEVELOPMENT PLAN 4052-99) - (+/-)8.727 SQ. FT. PROPOSED MANUFACTURING (PER SITE DEVELOPMENT PLAN 4*54-99) - <+/->2.3/2 SQ. FT. EXISTING OFFICE SPACE - (+/-)/0.272 SQ. FT. PROPOSED OFFICE SPACE (PER SITE DEVELOPMENT PLAN 4w50-99) - <+/->9,37/ SQ. FT. PROPOSED WAREHOUSE EXPANSION (PER SITE DEVELOPMENT PLAN '" /4-00) - (+✓->2,560 SQ. FT. PROPOSED FLAMMABLE STORAGE WAREHOUSE (PER THIS PLAN) - (+/-)720 SO. FT. GROSS FLOOR AREA - <+/-)242.988 SO. FT. PROPOSED OUTDOOR EMPLOYEE BREAK AREA (PER SITE DEVELOPMENT PLAN '"50-99) _ <+/->/.334 SQ. FT. PROPOSED RAIL SHED ADDITION (PER SITE DEVELOPMENT PLAN %* 2I-00) - (+/-)7.520 SQ. FT. TOTAL FLOOR AREA - <+/-> 2.51,842 SQ. FT. =:tl L TRIAD ENGINEERING, INC. HARRISONBU G VIRGINIA V S o � c w O O N O o N Oi U c N O Q o U N O F- F- o Z � 0 c v 0 v U V1 o p U U z z> a� c >3a LIJ o LLJ z0 0 ., z �� W J 2 U LLJ Ft QD r 0 Q F- J4,j,,�Lm U MDD n goon N66« ti OVAL E PROFESSIONAL SEAL W V7 O< z Z a: w 0 LIJ olf cif VDQ> Q / w Lv O >_ LrLJ —I O f-- LL.<? 0 O 0 z U � Q a L Y I of Q M W LJ Q 0 F LLJ 112f O 0 a Q LL- z J LL Q DrawingGJ L Number: N L C-2 1, , , I I , I i 1 RETAIL \ \ ZONED B-3 •\ I 54 ((A)) 84 -----------------------------------------------------------------1----------------------- n II 1 1 RETAIL 1 ZONED M-2 43 1(A)1 35 1 11 i 1-------------------------------------------------- 11 1NTX. R.R= I�--- — -------------------- STA. 8+89.29 ---------------------------------------------------------------�----- I--- ------------ -------- *�\----------------------------'N TF 22T 2Y' 801.W--------------------------------------------------------------------------------------------------------------------------------------------------- I - 1 \ � I I -------'�5"BU7'CD7RCSET6ACK--------1•---------------- ��-------------- , , PROPOSED RAIL \ \ j S/O/NG RELOCAT/ON n \ A/VO A00/T/0/V THIS PLAN SHEET FOR SITE ORIENTATION _ONLY. VACANT ZONED M-1 54 ((A)) 36G (OWNED BY KRAFT GENERAL FOODS) PROPOSED BUILDING \ A00/7-/0/V. REFER TO SITE DEVELOPMENT PLAN 4*14-00 NG SETBACK ------ / RETAIL ZONED B-3 / 54 ((A)1 85 / --------------------------------------------------------------- - -- I I i PROPOSED RA/LROAO SHED. 1 REFER TO SITE DEVELOPMENT j PLAN 0'2/-00 VACANT ZONED B-3 \ \ I 43 ((1) C -------------------- ..------- �; ���. 25' BUILDING SETBACK ` ` ` — — II PLANT` i II ,, NORTH ` I II it I 1 I I II II I 1 , REFER TO KRAF-r F0005 RAIL SIO//VG RELOCAT/O NO EXP MNS/ON I CHILLER DIKE I 1 ;I PAD FRUCTOSE iII Of?AW//VGS BY TR/ --H11V11 . /C. 61 TANKS RESIN SILO IOATEO /0-27-/9. EV/SEO�05-I6-�000. °) PAD SP�IL BAS�IN N IIAPPROV O BY CSX II �iLI III LII --LII LII LII III JII LII LII LII III —lII III III LII LII III JII _LII -LII LII IIUI I I 11 ---------- -- - --------------- ----------- I I -------------- ------------ iI��II1ItIIILrJ-1I�II -C rLIII _- 1rIII --�4III --4- rIII --A--4tIII --1rIII .-_-amJ -E------I------------------------ �-C�-r-C �-r_I-1-==T �TZ-III---------------------- =-j (--------S1_T-1-7_--I-T---1_Tr1 \-I- \- ------- I I t I iI 1, Zlrncu M-1 43 ((A)) 36 it I I I I I I I I I I I I I I I I I I I I I I I I I �� I \\ 11 ! 1 1 1 II 1 I I I I I I I I I I I I I I I I I I I I I I I WI I I IF II 11 li i I i ii C I I �L� oll I I I � _• ---� I A00/T/ON. REFER I i `t --- I i I _,i 11 I I I TO S/7TE OEVELOF'MENT I PLAN 0'50-99 I i -------i---- --- --------i---- -- -I I I ; I , I� 10 „1 11 I I -------1------ -J- --- --- 1---- --ml- I I -- --- --- ---- I------�-------�-------I---- IQ { Fr _ I I I I MANUFACTURING. STORAGE AND OFFICE BUILDING II _ _ , FLOOR ELEV.-690.0 II — — — — — J BUILDING HEIGHT{ ESS THAN 60' 1 I 1 FLOOR AREA=219.298 S0. !•'T. I+ L-j- L�L I-------1--------I-------J---- --- I ! II I I It I I MANUFACTURING ZONED M-1 I I -�---- -�------�---- II I 54 ((A)) 36H \II I I I 14------�---- --- I ---- ----I---- --- I I m m II i t , lI,I I I I -- ' -- ' -- I -- �J � i YI I I I l u--- -�---- -�---- ----- - 1 mcto I I I I - I-------J-------�---- --- 1 m< 0 _ I I II----r-------1--------,---- I --R—� ! s It I PROPOSED FLAMMABLEat STORAGE W AREHOCJSE — --- I I I (SEE SHEET C-4> ' Icn I I Lz> ww I--1-------�---- --- 7---- ---- 1 , I I ow I ; 14------�---- --- '-------�---- ----� I I'\ I I PROPOSEO BU/LO/NG o I I 1 __�____ - __ ___�____ ____I AOO//ON. REFER I I TO S/TETEEPET Ex. 2-4" OVLOM/V_- --- I I I J I '\ I CONDUIT r] i 1 II--- --- ---- --- i---- --- --- ----II wi------ II I I 1-------------y---- --- --- ----I m� I II ' I IT -1=/IIVW I I II'a II I I Il I ��idy.�l ��Lr7---------------- — I I I—TI 4• I I I I I 1 1 I III I II y l i I I I .:d1.. o II I I I I I11 I I I \I I I I I ilf I Y I �—---------------- I I I I ,i ' I r--- ii `� i�u.� i I — ------I �_ I I :lr.• II II li i /,, i �i I III I I I r I I ' I II / I II 11 T 4. II °:I I / I I MANUFACTURING ZONED M-1 PROPOSEO BU/LO//VG 54 (( A)) 36L A AOO/T/ON. REFER I 7 -0 S/TE DEVELOPMENT I -4 I I PLAN 41SO-99 1 I ' I � I I I II p I 1 1 :I�.• II ,� Y I m! I y 1 I I I I I II 11 .. -�'•, I I , 1 I I I — J— —a I � 11 I 1 i'L.Kt`.;,"'`.'•.'''•.::,'t,,�al;-, II � Y 1O! I I I I if� _-------.ij4-�----- ----- 75' BUILDING SETBACK ---------------- I !I I ' 1 - II H L - - -�- -T-- _ -- -- - - - - - - --------- �1-------- 1 II <1 II H 1 I II I I i I I I! I I 1 1 I Rom°:00' ------- ----- -- S 47• ------ 22' 1042_1T'---------------�-�� -- 1 I �— — — — --- --- , 1 1 II WEST BROOKE RQAD (ROUTE 1320) I I 60 R/W , 1 EX. 2-4"— I , II POSTED SPEED=35 M.P.H. 1 1 1 CONDUIT 11 -----------------LL------------------------------------------------------------�-1-1--------------------- It ----------------------------------------------------------------------------- - _ I _�\-------I i t - - 1 v S\-------i--- i 1 VACANT ; I 1 ZONED M-1 \ I I I 54 ((A)) 360 I SEW. ESM' T. I I I I I N MR1 L TRIAD ENGINEERING, INC. 0 c rn � o O cV O U CV 0 0 o o cal • • O O C N -0 0 0 O (1 T � Q U Q o r o U z 0 a z A c,y -, [if Uj 3 LLJ o Ld Z� co V L w 0 LJ Z Loow J w x vi LLJ ; 0 Q v IM D.1r00D Na0ti�61 1 ZONAL E PROFESSIONAL SEAL. V) LLJ z O Q 0 Z �_ W0 c) ry Of () Q > z 0 O > U owe- LL.Q:D Cr- 0 O W F— 0 U F— � V) V) elf Y - m W Qo v z LL- V J �- X W Drawing Number: C-3 I� F NOTES: BUILDING OFFICIAL'S NOTES: 1J MAX/MUM BUILDING HEIGHT FOR ZONING DISTRICT M-1 IS 60' PER SECTION 165-83A OF THE FREDERICK COUNTY ZONING ORDINANCE. THE HEIGHT OF THE PROPOSED BUILDING /S LESS THAN 60'. 2J UTILITY SERVICE TO WAREHOUSE SHALL BE PROVIDED FROM EXISTING BUILDING. NEITHER OVERHEAD NOR UNDERGROUND ELECTRIC SERVICE IS REQUIRED. 3J SEE ARCHITECTURAL/MECHANICAL DRAWINGS FOR THE ROUTING OF UTILITIES WITHIN THE PROPOSED WAREHOUSE. 4J SEE ARCHITECTURAL/STRUCTURAL DRAWINGS FOR FOUNDATION DETAILS AT EXISTING UTILITY CROSSINGS, DOOR LOCATIONS, STOOPS, ETC. 5J THOUGH NOT SPECIFICALLY DEPICTED HEREIN.SCOPE OF WORK FOR THE PROPOSED WAREHOUSE SHALL INCLUDE ALL REQUIRED DEMOLITION. 6J CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF ALL EXISTING UTILITIES PRIOR TO INITIATION OF ANY CONSTRUCT/ON ACTIVITIES. 7J ROOF RUNOFF SHALL BE CONVEYED AWAY FROM THE BUILDING EXTERIOR VIA DOWNSPOUTS AND SPLASH BLOCKS OR TIED DIRECTLY TO EXISTING STORM DRAINAGE SYSTEM. REFER TO ARCHITECTURAL DRAWINGS BY STAHLMAN ENGINEERING CORPORATION FOR RELOCATION OF EXISTING SCUPPER DRAINS AND LOCATION OF PROPOSED SCUPPER DRAINS. 8J BUILDING SETBACK REQUIREMENTS /N ZONING DISTRICT M-/ PER THE FREDERICK COUNTY ZONING ORDINANCE ARE AS FOLLOWS: -FRONT YARD SETBACK ON PRIMARY OR ARTERIAL HIGHWAYS - 75' -FRONT YARD SETBACK ON COLLECTOR OR MINOR STREETS - 75' -SIDE YARD SETBACK - 25' -REAR YARD SETBACK - 25' 9J BUILDING SETBACKS PROVIDED: -FRONT YARD BUILDING SETBACK PROVIDED TO THE EAST (PARK CENTER DRIVE) - N/A -FRONT YARD BUILDING SETBACK PROVIDED TO THE SOUTH (WEST BROOKE ROAD) - /60J' -SIDE YARD BUILDING SETBACKS PROVIDED TO THE WEST - 1094.6' -REAR YARD SETBACKS TO THE NORTH (CSXT R-O-W) - N/A /OJ ALL SIGNS LOCATED ON THIS PROPERTY SHALL CONFORM WITH THE STANDARDS OF THE FREDERICK COUNTY ZONING ORDINANCE. I /3J ALL OUTDOOR LIGHTING FIXTURES ASSOCIATED WITH THIS BUILDING ADDITION ARE SURFACE MOUNTED ON THE FACE OF THE BUILDING. SEE ARCH. PLANS FOR LIGHTING SPECIFICATIONS. OUTDOOR LIGHTING SHALL BE ARRANGED TO DEFLECT GLARE AWAY FROM ADJOINING PROPERTIES AND PUBLIC STREETS. (PER .SECTION 165-35A OF THE FREDERICK COUNTY ZONING ORDINANCE). 14J THERE ARE NO PROPOSED EASEMENTS /N ASSOCIATION WITH THE CONSTRUCT/ON ------------ OR OPERATION OF THIS WAREHOUSE. 15J THE OUTDOOR TRASH RECEPTACLE /S A FULLY ENCLOSED AND SELF-CONTAINED TRASH I I o COMPACTOR WITH ACCESS ONLY FROM THE INTER/OR OF THE BUILDING. THE ENTIRE CONTAINER WILL BE REMOVED AND REPLACED WHEN FULL PROPOSED FLAMMABLE l STORAGE WAREHOUSE approximate II (72i0 SO. I ocat i on of existing st i n san. m/h REMOVE EXISTING _ existing san. m/h PROPOSED RELOCATION 9 I I top =6 8 5. 7 9 OF EXISTING ll' x 2F F.F.-690DO existing d u mp s t e r s top =6 8 8. 9 0 6' SAN. LAT., PLUG 4" inv. in=679.29 TRASH COMPACTOR 6" inv. in=684.45 M/H AS NECESSARY I i I II L] -6" inv. out=683.81 (PER SITE DEVELOPMENT16" inv. i n=6 7 8. 8 4 exist. (SEE ARCH. PLANS exist. PLAN •52-99) I e x i s t i hg stm m/ exist. 6" inv. i n=679. 14 roof drain FOR PAD DETAILS) roof drain roof drain 1 0" inv. out=678. 92 ex. w. v. I top`-688 . 77 I _ existing building line I (8" inv I. i6844.1Y�I ,•r \ -----------_-------------------- �p N_•,I / I I ------. -•- -I- ---- -,,-,-`-�-/IIlIIRrII -- --J 8" nv.IlIIIi ou= II 6 existing stm mh ,I I'� top=685.94 existing stm m/h 000 Ii12 inv. in=680.75 existing stm h top=685.59existIhoof drain inv. in=680.65 to-685.68 inv. out=683.03 f1 _______________ A I-12tinv. out=680.56 I / i e�xisting edgee nl of pavemen 'q•1 d 1�I ?L - �- / \ \1 Iit II \\ ; •tp Ir v U --'` I,I•to'', 3 311; I I , , f, 11 \ I ' CONVERTED EX. 6' SANITARY . • I I ' ; '.. I / ,� -' " II �; 11 \ ; i SEWER TO FLOOR DRAIN FROM existing s t m. m/ h I r . ° - - _ _ = ;' I 1 \ �� , , ;I+ I I CAPR/ SUN 2" BUILDING ADDITION top =6 8 5.8 9 l8 ; F I, -. I m I I X 3 3 (PER WASTEWATER TREATMENT 15 „ inv. i n=679.83 • . °�-�". I /I? \ rp . II ----� f' II / I 10 inv. in=680.29 I II I I /il i,� _ , \ 11 / i I BUILDING ADDITION 7 1 0 " inv. i n =6 8 0. 1 6 I I I U I ::CHILLER CHILLER PAD/ / , - _ _ - _ - - - - - - �^r�i I PLANS, DATED //­04-99) t, I ° I II 0 c 1 n FF.-686.00,- �-�`/i\� 15 inv. out=677.51 '.;lito.;. I o o I II _ - ,,- existing stm m/h -/ 'I';' I+ ,� °�� I ----- III--___,� ; _ (PER „SITE DEV- LOPMENT ___---- _ ------ Ire -�--- - --,- ---------------- -- X XIIII, II PLAN �r99) top=685.77 �Ir /�--Tr- -- 1 ---- -- --- ,.1•I. m m I! 1 2" inv. I n=680. 10 /I / existing i REFER TO ARCHITECTURAL III ------ It`- 12" inv. out=679. 77 /I 11 ' Iii-- / I / I I silo DWGS FOR EXACT BUILDING tII l l 11 I DIMENSIONS, EXTERIOR : i i•t; I _ _ �I�/ It l I 11 DOOR LOCATION, AND Ii1i I STAIR/LANDING DETAILS •,; I l i g - / ll I it i ���'''- x4- I In, ex i sting edge it I ii _ PROPOSED FIRE LANE '°rl •- of pavment co 1 i 11 S/GNAGE AND 6 x 20' . I I . I I I , X PAVEMENT MARKINGS II I 11 AT EXISTING FIRE HYDRANT 00 (EXACT LOCATION TO BE I DETERMINED BY THE FIRE •to I I • CAPRI SUN BLDG. IT/ON - I lex i s i ng edge 11 I MARSHALL) I •' ° ` PROPOSED USE. MANU ACTURING ij of a v emen t I'1 11 I .,o .�; : •, (PER SITE DEVEL0 4MENT,' 52-99) 1 PLAN s � II / •- - - . , I I - , 75'BUILDING SETBACK -- °. ". •.°. °- •.°. Pr •. • ----' I ------ --r-� �4-------- --- 75'BUILDING SETACK - +r- - - - - ex. -------41------------------------ - - - 1L------ _-- '� 10 f/I -�---�--�------------�---______-----existing fire / , hydrant--_'' --------'\ 1 111 existing sa m/h ------- `---------------- +a -__ _top=685. 3 ++ 10'rin n= 77.74 1 0_ inv. u'� 677. 68 �- \ ' "•�'- / \------------------------ / 11 \� I I ,� �� _-_ _----,---------------------- _ _ / IIII - r---------------------------� ____i��_ \I h i------------- 11 / /------I- - ---------------- - - - - -- I - \\� - �--�---- -x--1_------------------------ / 11 \ \----------- --------- / it,- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - 60 RIGHT-OF-WAY-_ _ _ _ _ _ _ _ _ _ _ , -------------------------------------------- �fJ;--- - /���" "-------------------------------------------------------------------------- _ --- - - - - - - - - - - - - - - - -------- _ _ _ _ ---__---------------------------------------------�---------- -------------- _ ---- _--------- -- (RIGHT F WAY ------- _-___ � ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- - PLANT NORTH IJ ADDITION SHALL COMPLY WITH THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE AND SECTION 307, USE GROUP H (HIGH HAZARD), OF THE BOCA NATIONAL BUILDING CODE -19% PLEASE NOTE SECTIONS 507 (UNLIMITED AREA BUILDINGS), TABLE 707J (FIRE WALL AND PARTY WALLS), 904 (FIRE SUPPRESSION SYSTEM) OF BOCA. 2.) AT THE TIME OF PERMIT APPLICATION, PLEASE SUBMIT INFORMATION ABOUT THE AMOUNTS AND TYPES OF FLAMMABLES TO BE STORED. 3J ALL PLANS SUBMITTED SHALL BE SEALED BY A LICENSED ARCHITECT/ENGINEER REGISTERED IN VIRGINIA. llJ NO OUTDOOR STORAGE /S PROPOSED WITH THIS WAREHOUSE. 12) THERE ARE NO EX/STING SIGNIFICANT ENVIRONMENTAL FEATURES. =:?I TRIAD ENGINEERING, INC. 4) 0 O N O U N p c o p CN o v= o o 0 ° cn T >> � T � � � p c U ni p t p U U Z 4% r� V Z ry W ILj Z Z LLJ Q Of a a> > w jz >, �,.s N 0 LLJ 3 m W v 'Iwo 11< WOOD NcxOaM yo �"QXAL PROFESSIONAL SEAL Ld V) Oz W C� 0�\�_ V/Q/ 0 O �- LL] O Q Z of, 0 F- 0O U Q V Y Y-j m W Q 0 W Q J II Z n� L,J V) Drawing Number: C-4 N L