HomeMy WebLinkAbout22-05 Nextel Partners VA259P - Relocation of Telecomm. Equip. - Gainesboro - Backfilem PROJECT DESCRPTK)N THIS PROJECT CONSISTS OF THE LOCATION OF NEW ANTENNAS ON AN EXISTING MONOPOLE TOWER. A 10'X22' PREFABRICATED EQUIPMENT SHELTER IS PROPOSED TO BE LOCATED WITHIN THE EXISTING GRAVELED COMPOUND. SffE INFIECIKM From Roanoke: I81- North to Winchester. Exit Route 37 at exit tf 310. Head North on Route 37 approx. 9 miles to Route 522 West. Turn left off the exit and travel 2.5 miles to Footstone Lane on the right. Turn Right and follow back to site SITE NAME WEST WINCHESTER SITE NUMBER VA259P SITE ADDRESS SITE COORDINATES: LATITUDE: N39'14'38.76" (NAD 83) LONGITUDE: W78°11'47.57if (NAD 83) GROUND ELEV.: 1172' (NAVD 88) *SITE PLAN EXPIRES FIVE YEARS FROM DATE OF APPROVAL* SITE INFORMATION JURISDICTION: FREDERICK COUNTY TAX MAP & PARCEL 42-A-332 D.B.: 839 PG 136 CODE: BOCA OCCUPANCY: CO LOCATION ZONING: RA -RURAL AREAS CONSTRUCTION TYPE: PREFABRICATED MAGISTERIAL DISTRICT: GAINSBORO PROPERTY OWNER OR REP. CONSTRUCTION ZONING REAL ESTATE , Tl- C1.; C2 C3 C4 C5 S1 S2 S E 1* E2 E3 E4 E5 E6 NETWORK OPERATIONS OTHER f, f SHEET INDEX TITLE SHEET SURVEY EXHIBIT SITE PLAN AND TOWER ELEVATION CIVIL DETAILS CIVIL NOTES EQUIPMENT CABINET STRUCTURAL FOUNDATION PLAN, DETAILS & NOTES STRUCTURAL DETAILS STRUCTURAL DETAILS, NOTES & ANTENNA SCEHDULE ELECTRICAL LEGEND & NOTES EQUIPMENT & UTILITIES SITE PLAN EQUIPMENT & UTILITIES SITE PLAN ELECTRICAL GROUNDING DIAGRAM & DETAILS ELECTRICAL- UTILITY DIAGRAM & DETAILS ELECTRICAL DETAILS 1�1�_* I I trox � [Q &"� AkM LANDLORD CROWN CASTLE USA 2000 CORPORATE DRIVE CANONSBURG, PA 15317 CONTACT: JANICE WELCH PHONE: (540 ) 353-2070 CONSULTANTS CIVIL/SURVEYING/STRUCTURAL DRAPER ADEN ASSOCIATES 8090 VILLA PARK DRIVE RICHMOND, VIRGINIA 23228 PHONE: 804-264-2228 FAX: 804-264-8773 MISS UTILITY CONTRACTOR TO CALL 48 HOURS BEFORE DIGGING! PHONE: (800)552-7001 CONTRACTOR RESPONSIBLE FOR DAMAGE OF EXISTING UTILITIES DURING CONSTRUCTION APPLICANT NEXTEL PARTNERS 5115 BERNARD DRIVE SUITE 200 ROANOKE, VA 24018 PH: 540-725-4905 FAX: 540-725-4950 CONTACT: MONIQUE FRUIT Draper Aden Associates Engineering • Surveying i Environmental Services 8090 Villa Park Drive Richmond. -VA 23228 804-264-2228 Fax: 804-264-8773 Blacksburg, VA Charlottesville, VA Hampton Roads, VA Raleigh -Durham, NC www.daa.com NEXTEL PARTNERS, INC. 5115 BERNARD DRIVE, SUITE 200 ROANOKE, VA 24018 SEAL:4—MOWIV - IL I A, 4:. is SUBMfrTALS/REVISIONS NO. DESCRIPTION DATE 1 LEASE EXHIBIT ISSUED FOR APPROVAL 12/22/04 2 CONSTRUCTION ORAWNGS ISSUED FOR REVIEW 01/28/05 3 CO'S REV. PER NEXTEL PARTNERS COMMENTS 02/11/05 4 CO'S REV. PER FREDERICK COUNTY COMMENTS 05/03/05 ELECTRICAL DUNLAP & PARTNERS 2112 WEST LABURNUM AVENUE SUITE 201 RICHMOND, VIRGINIA 23227 PHONE: 804-358-1100 FAX: 804-358-1188 5 6 7 SITE No: DRAWN BY: CHECKED BY: SCALE. Ti TLE: ALLEGHANY ELECTRIC POWER PHONE: 1-800-255-3443 VERIZON PHONE: 800-826-2355 VA259P JJF SJS AS NOTED TITLE SHEET SITE: VA259P WEST WINCHESTER 294 FOOTSTONE LANE WINCHESTER VA, 22603 SHEET NUMBER: JOB# R04724 Ti LINE TABLE LINE LENGTH BEARING DESCRIPTION L1 38.14 S85'33'42"W TIE —LINE L2 25.00 S20'42'45AW LEASE AREA L3 15.00 N69'17'15QW LEASE AREA L4 25.00 N20'42'45aE LEASE AREA L5 15.00 S69-17'15"E LEASE AREA L6 93.74f N21'10122"W TIE —LINE L71 93.98 1 S69'37'56"W JACCESS EASEMENT SURVEY EXHIBIT LEGAL DESCRIPTION GPS #1 ROD SET I N:7136315.350 Fp0 E. 1156978&531 ELEV.:1167.97 I UNE tzi58't - . Ix OVERHEAD POWER LINE ACCESS EASEMENT REFERENCE (INST. # 10008409 PG. 285) ` EDGE 20' WIDE v�- NEXTEL PARTNERS ' ACCESS EASEMENT 'J EXIST. GRAVEL C/L 20' WIDE NEQXTEL PARTNERS ACCESS EASEMENT \ EXIST. FENCE x x x --- �, EXIST. CHAIN N-7136251.25119 13`' �— _, x LINK FENCE F-11568844.01029976 P.O.B. #1 ELEV. 1170.94 I N 42-A-332 JAMES I.. & CHRIST IE A. PATTON D.B. 839 PG. 136 ZONED RA N 42 280 JAMES D. SHOCKEY JR. D.B. 565 PG. 349 ZONED RA SCALE: 1 " = 20' (HALF -SCALE) PARENT TRACT I LEGAL DESCRIPTION LEASE AREA ALL THAT CERTAIN TRACT OR PARCEL OF LAND LYING AND BEING SITUATED ON NORTH MOUNTAIN IN GAINESBORO MAGISTERIAL DISTRICT, FREDERICK COUNTY, VIRGINIA, CONTAINING FIVE ACRES AND BEING THE SAME PROPERTY CONVEYED TO THE GRANTORS HEREIN BY DEED FROM JOSEPH B. LINTZ, HIS WIFE, DATED FEB. 31, 1995, AND RECORDED IN THE OFFICE OF THE CLERK OF THE CIRCUIT COURT OF FREDERICK COUNTY, VIRGINIA, IN DEED BOOK 8349 AT PAGE 505. REFERENCE IS HERE MADE TO THE AFORESAID INSTRUMENTS, THE ATTACHMENTS THERETO AND THE REFERENCES THEREIN CONTAINED FOR A FURTHER AND MORE PARTICULAR DESCRIPTION OF THE PROPERTY HEREBY CONVEYED. COMMENCING AT A PIPE FOUND, LABELED AS SUCH ON THIS PLAN, THENCE S85033'42"W 38.14' ALONG A SURVEY TIE -LINE TO THE TRUE POINT OF BEGINNING LABELED P.O.B. #2; THENCE S2(T42'45"W 25.00 TO A POINT,.. THENCE N69' 17' 15" W 15.00 TO A POINT, THENCE N20'42'450E 25.00 TO A POINT, THENCE S69' 17' 15NE 15.00 TO POINT OF BEGINNING. CONTAINING 375 SQ. Fr. OF LAND / x /L4 15'X25' x NIXTEL PARTNERS F " I LEASE AREA / I CA EXISTING MONOPOLE _ IN: 7136284.37189498 1.4 17.9' E.- 11568863.44937557 P.O.B. f2 E LEV. AT BASE: 1172 a�. ROD FOUND (DISTURBED) 124.. 0 N:7136180.21996098 15 E:11568871.39918955 PPE FOUND j ( N:7136290.68037376 EA 1568928.07645870 V O O ROD FOUND IN: 7136156.13300579 E: 11568937.17136514 PARENT TRACT PROPERTY UNE SCALED FROM TAX MAP AND IS APPROXIMATE LEGAL DESCRIPTION ACCESS EASEMENT COMMENCING AT A ROD FOUND, LABELED AS SUCH ON THIS PLAN, THENCE N21'10'22"W 93.74' ALONG A SURVEY TIE -LINE TO THE TRUE POINT OF BEGINNING, LABELED P.O.B. #1 THENCE S69'37'56" W 93.98f TO A POINT ALONG THE CENTER LINE OF FOOTSTONE LANE,, THUS TERMINATING THE EASEMENT. PARF7W TRAICT PROPERTY UNE 9CAj M FROM TAX MAP AND IS APPROXIMATE 1 GRAPHIC SCALE I 20 0 1D 20 40 i ( INFEET ) I inch = 20 fL PROJECT SITE WE - SITE NUMBEFc SITE ADDRESS: 294 FOOTSTONE LANE WINCHESTER, VA 22603 CROWN CASTLE USA 200 CORPORATE DR. CHARLOTTESVILLE, VA 22903 (434)295-3595 CENFM C F TMER LATITUDE; N3914'38.76' LIONGII UDE: W781I447.5r GROUND ELEVATION: 1172' PARAPET ELEVATION: N/A BASIS OF ELEVATIONS: GPS OBSERVATIONS RECORDED ON 12/09/04. TO 50' HORIZONTAL, BASED ON NAD 83 VIRGINIA NORTH ZONE, AND 20' VERTICAL, BASED ON NAVD 88. BASIS OF BEARINGS: GPS OBSERVATIONS RECORDED 12/09/04 NI LATITUDE AND LONGITUDE SHOWN HEREON ARE BASED ON NAD 83 VIRGINIA NORTH ZONE AND ELEVATIONS NAVD 1988. BASE MAPPING FURNISHED BY A DECEMBER. 2004 DRAPER ADEN ASSOCIATES GPS SURVEY. OWNERS NAME INFORMATION WEST WINCHESTER VA259P BENCH MARK: ROD SET ADJACENT TO ACCESS DRIVE. TBM ELEVATION 1167.97'. BY GRAPHIC PLOTTING ONLY, THIS PROPERTY IS WITHIN ZONE "C", AREAS OUTSIDE OF A 100 YR. OR 500 YR. FLOOD PLAIN AS SHOWN BY FIRM MAP COMMUNITY -PANEL NUMBER 213221A, DATED MARCH 3, 1983. NO SURVEYING WAS DONE TO DETERMINE THIS FLOOD ZONE. A CURRENT FIELD BOUNDARY SURVEY WAS NOT PERFORMED AT THIS TIME. SUBJECT TO ANY STATE OF FACTS THAT AN ACCURATE BOUNDARY SURVEY WOULD DISCLOSE. SUBJECT TO ALL RIGHTS, EASEMENTS, COVENANTS OR RESTRICTIONS OF RECORD. SUBJECT TO ANY STATE OF FACTS THAT AN UP-TO-DATE ABSTRACT OF TITLE WOULD DISCLOSE THIS PLAN WAS PREPARED WITHOUT THE BENEFIT OF A TITLE REPORT. THIS PLAN IS NOT FOR RECORDATION OR CONVEYANCE. WNI -I --- -'�- ---__ Draper Aden Associates Engineering • Surveying • Environmental Services 8090 Villa Park Drive Blacksburg, VA --�1�-- Richmond, VA 23228 Charlottesville, VA ----- 804-264-2228 Hampton Roads, VA Fax- 804-264-8773 Raleigh-DurtTam, NC www.daa.com LEGEND -O- POWER POLE 11--- GUY ANCHOR 0 TELEPHONE PED. ® WATER VALVE -61 F1RE HYDRANT TBM (ROD SET) -Q- UGHT POLE IRS IRON ROD SET IRF IRON ROD FOUND Tel: BUILDING LINES ACCESS EASEMENT UTILITY EASEMENT AZIMUTH LINE —x—x— FENCE LINE POWER UNE LEASE AREA PROPERTY LINE SURVEYOR'S CERTIFICATE 00 NOMEL PARTNERS, INC. 5115 BERNARD DRIVE. SUITE 200 ROANOKE. VA 24018 SEAL_ , NLT H OF 4, O ERWIN J. I`ANO No.2�4 7 Z- (f C - -: 5 :r 6 SITE NO: VA259P 7 DRAWN BY: JJF 37 _ _r. .. CHECKED BY.• LOW / . , PF! If -r.max _ Tt -n AS A REGISTERED PROFESSIONAL LAND SURVEYOR, 1 DO HEREBY CERTIFY THAT THIS MAP REPRESENTS THE RESULTS OF A PARTIAL SURVEY MADE UNDER MY DIRECT SUPERVISION AND IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. THIS MAP DOES NOT REPRESENT A BOUNDARY SURVEY OF THE UNDERLYING PARCEL THE LEGAL DESCRIPTION SHOWN HEREON WAS OBTAINED FROM THE DEEDS RECORDED WITH THE PERTINENT COUNTY/CITY ENTRY. THIS MAP DOES NOT REPRESENT A TITLE SEARCH. ADDITIONAL EASEMENTS AND/OR RIGHT-017-WAYS MAY EXIST. DATE 12/22/04 01/28/05 02/11 /05 05/03/05 SURVEY EXHIBIT S1"E' VA259P WEST WINCHESTER 294 FOOTSTONE LANE WINCHESTER VA, 22603 SHEET NUMBER: C1 JOB/ R04724 I/ N, 1 I I I 1 I I I I I I I I I I I I I J k k k EXISTING WHITE k BOARD FENCE k k 0 EXISTING STONE SURFACED �_X_ PARKING/TURNAROUND AREA. EXISTING H-FRAME W/ TELCO. EQUIP. EXISTING METER BASE (NEXTEL PARTNERS TO USE "C OR D") EXISTING 142' MONOPOLE EXISTING ICE BRIDGE W/ EQUIPMENT EXISTING 12' WIDE ---/ DOUBLE SWING GATE / / r GRAPHIC SCALE 5 0 25 5 10 i IN FEET 1 inch = 10 fL rTSITE PLAN C2 SCALE: 1"=70' -_k EXISTING 138' TOWER J EXISTING ICE BRIDGE (TYP.) IUL UNIDUL PROPOSED GPS UNIT PROPOSED NEXTEL PARTNERS 15'X25' LEASE AREA PROPOSED GPS UNIT PROPOSED 10'X20' NEXTEL PARTNERS EQUIPMENT SHELTER EXISTING LIGHTNING ROD IN EXISTING ANTENNAS Draper Aden Associates Engineering • Surveying • Environmental Services 8090 Villa Park Drive Blacksburg, VA Richmond, VA 23228 Charlottesville, VA s r 804-264-2228 Hampton Roads, VA -E Fax: 804-264-8773 Raleigh -Durham, NC -� - www.daa.com r � _` EXISTING ANTENNAS . .. T Ole,INc PROPOSED NEXTEL FLUSH No MOUNTED ANTENNAS RAD CENTER 112' (AGL) PROPOSED (9) 7/8" COAX MOUNTED EXTERNALLY (STACKED 4 ON 5) EXISTING 142' TALL MONOPOLE PROPOSED ICE BRIDGE PROPOSED 101X20' NEXTEL PARTNERS EQUIPMENT SHELTER EXISTING EQUIPMENT NOT INDICATED FOR CLARITY s'� TOWER ELEVATION VIEW CZ I SCALE: NTS NEXTEL PARTNERS, INC. 5115 BERNARD DRIVE, SUITE 200 ROANOKE, VA 24018 SEAL: NO. CY19422 �ry S �Au OPIAL SUBM(TfALS/REVISIONS NO. DESCRIPTION DATE 1 LEASE EXHIBIT ISSUED FOR APPROVAL 12/22/04 2 CONSTRUCTION DRAWINGS ISSUED FOR REVIEW 01/28/05 3 CO'S REV. PER NEXTEL PARTNERS COMMENTS 02/11/05 4 5 6 7 SITE NO: VA259P DRAWN BY: ??? CHECKED BY: TKD SCALE: AS NOTED TITLE: SITE PLAN AND TOWER ELEVATION SITE: VA259P WEST WINCHESTER 294 FOOTST®NE LANE WINCHESTER VA, 22603 SHEET NUMBER: C2 JOB# R04724 1. SET THE STAKES. 6' MAX. 3. STAPLE FILTER MATERIAL TO STAKES AND EXTEND IT INTO THE TRENCH. 2. EXCAVATE A 4"x 4' TRENCH UPSLOPE ALONG THE LINE OF POSTS. 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. CHAIN LINK TOP SELVAGE BARBED AND TWISTED BOTTOM SELVAGE KNUCKLED, INSTALL FABRIC ON OUTSIDE (NON —SECURE SIDE) MALLEABLE IRON FORK TYPE 12'-0" GATE OPENING LATCH WITH DROP BAR AND WITH PROVISION FOR PADLOCK (PAGE—WILSON TYPE 75 DOUBLE GALVANIZED GATE CENTER STOP— GATE FRAME GATE LATCH ASSEMBLY OR 6 1/2" DIA. WITH 1 1/4" SLOT, 1 CLASS B STEEL EQUAL) TUBING 1 7/8" 3/8" SHANK IN A 1 5/8" DIA. OD (TYP.) GATEPOST 4" OD GALVANISED STEEL hr= I/-- (TYP.) PIPE SET IN CONCRETE. 1-1/2 PAIR INDUSTRAIL l III MALLEABLE IRON OFFSET PIN HINGE • I11 Vim -------------------- 1 • M-6 OR EQUAL) ELECTRICAL COPPER —'-1 f 911 BRAID (TYP.) SEE 2" MIN. SHEET FLOW INSTALLATION GROUNDING DETAILS CLEARAN (P(PERSPECTIVE VIEW) CLEARANCE � 8.. � 6 POINTS A SHOULD BE HIGHER THAN POINT B. DRAINAGE INSTALLATION (FRONT ELEVATION) 1 SILT FENCE DE E 3 NOT TO SCALE (WITHOUT WIRE SUPPORT EQUIVALEN 1) TAIL DE TO DRAIN Y FROM zR 3 FENCE C3 NOT TO SCALE C c u 0 6" ill=flllll=l �1=AIL=—fllfll- = —. ,—• — _ — 11===flllll=lfll I�III =flI _ II fllflh -_ -� _--=--=u I fll_M=1� I_N n= I III 1 =fllfl IIIIS ' _' . • , 11�=Allfl�l�11 mil —� �_ ='ii =�t� — =pIIN=Mill =111fll=gllfl=11=111p1=IIIlfl=lrll=111=Ullfl'=11fl1Ul III pill=llHfl=I�III_Il�Ii=IIUu=111111=�=i�= • _ nl _ GATE DETAIL NOTE: NOT ALL DETAILS INCLUDED ON THIS SHEET ARE REQUIRED FOR THIS PROJECT. 12' 6" STONE SURFACE #57 COARSEAGGREGATE MAX. 3:1 (PER VDOT SPEC) SLOPE 2% MAX. 12" COMPACTED SUBGRADE @ 98% STD. PROCTOR GEOTEXTILE FABRIC ? l SECTION THROUGH TOWER YARD. 4 SECTION TH, C3J u0i TO SCALE C3 I NOT TO SCALE 8" TYP. EXISTING SUBGRADE MAX. 3: 1 SLOPE BARBED WIRE ARM ANGLED 45- OUTWARD (TYP.) ER POST, CLASS B _ TUBING 4" OD ) Draper Aden Associates Engineering +Surveying +Enviro=wft1Services 8090 Vlia Paris Drive Blacksburg, VA Richmond, VA 23228 Charlottesville, VA 804-264-2228 Hampton Roads, VA Fax: 804-264-8773 Raleigh -Durham, NC SEAL www.daa.com NEXTEL PARTNERS, INC. 5115 BERNARD DRIVE. SUITE 200 ROANOKE, VA 24018 PION. SUBMITTALS/REVOOM NO. DESCRIPTION DATE 1 LEASE EXFII8IT ISSUED FOR APPROVAL 12/22/0� 2 CONSTRUCTION DRAWINGS ISSUED FOR REVIEW 01/28/05 3 CD'S REV. PER NDaa PARTNERS CONVENTS 02/11/05 4 5 6 7 SITE NO: VA259P DRAWN BY: ??? CHECKED BY: TKD SCALE: AS NOTED CIVIL DETAILS SITE: VA259P WEST WINCHESTER 294 FOOTSTONE LANE WINCHESTER VA, 22503 SHEET NUMBER: C3 JOB# R04724 r S,`.> f"`- ."�i X.: 4 z I # ;_ U1, W I D071 • ■_ • -•` • as A 2. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING A NEAT r ORDERLY ,.D AND GROUNDS. REMOVE AND DISPOSE OFF SITE ALL RUBBISH,MATERIALS, FOREIGNLITTER, AND ALL : , REMOVE PETRO—CHEMICAL SPILLS, STAINS AND OTHER FOREIGN DEPOSITS. RAKE GROUNDSTO • SMOOTH EVEN —TEXTURED ■ . 3. LOCATION OF EXISTING SUBSURFACE STRUCTURES, ABOVE GROUND STRUCTURES AND/OR UTILITIES WITHIN THE AREA OF PROPOSED • ■ , ■ NOT ■: SHOWN• CORRECT.THE PLANS, AND IF SHOWN ARE ONLY APPROXIMATELY CONTRACTOR'S ■,•RRESPONSIBILITY • VERIFY LOCATION OF ALL SUBSURFACE STRUCTURES AND UTILITIES O. TO STARTING WORK.• PRIOR TO ANY DIGGING OR DRILLING, CONTACT LOCAL UTILITY LOCATING SERVICE. 4. THE OWNER •,, • REPRESENTATIVE SHALL BE NOTIFIED IN WRITING OF ANY CONDITIONS THAT VARY FROM THOSE• ON • •■ WORK SHALL NOTFROM EXPRESSAPPROVAL OF OWNER OR • ■ • 6. THE CONTRACTOR SHALL RESTORE ALL PUBLIC OR PRIVATO PROPERTY DAMAGED OR REMOVED TO AT LEAST • O • • r•BEFORE DISTURBED DETERMINED BY THE OWNER OR REPRESENTATIVE. 7. THE CONTRACTOR • REQUIRED 8. THE CONTRACTOR SHALL PROTECT EXISTING PROPERTY LINE MONUMENTATION. ANY MONUMENTATION DISTURBED OR DESTROYED, r r BY THE OWNER OR THE OWNER'S REPRESENTATIVE SHALL BE REPLACED AT CONTRACTORS UNDER• OF LICENSED LAND SURVEYOR. 9. ALL EXCAVATION r ANY REQUIRED SHEETING r a REGULATIONSSHORING SHALL BE DONE IN ACCORDANCE OSHA FOR • • 10. CONTRACTOR BE RESPONSIBLE FORDEWATERING ANJ THE MAINTENANCE OF -FACE DRAINAGE DURING THE COURSEOF O 11. ALL •■K INVOLVING CONNECTIONSTO EXISTING SYSTEMS SHALL BE OWNER. NOTIFY THE CONSTRUC-HON MANAGER r THE UTILITY OWNER BEFORE r EVERY CONNECTION TOMADE. 12. MAINTAIN FLOW FOR ALL EXISTING UTILITIES. likols r•I■rMORN04• . 14. CONTRACTOR TO GRADE ALL AREAS ON PROVIDE POSI_nVE DRAINAGE AWAY FROMr OR EQUIPMENT'`r AND THE TOWER. 15. PROPOSED TOWER FOOTING/FOUNDATIONDIMENSIONS ANY) ARE SHOWN • ■ GENERAL . INFORMATION ,.• PURPOSES ONLY. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ACTUAL FOUNDATION DIMENSIONS WITH FINAL TOWER DESIGN AND FOUNDATION DESIGN AS PROVIDED BY TOWER MANUFACTURER. 17. NOTE THAT ALLDIMENSIONS, • 1 EXISTING CONDITIONS S• ON DRAWINGS SHALL BE FIELr: VERIFIED BY THE CONTRACTORPRIOR TO BEGINNING MATERIALSORDERING,•■R• • OR CONSTRUCTION • ]\ . 18. THE CONTRACTOR REWORK r•SCARIFY, ALL MATERIAL • • - r CONTRACTORSTATE. IF THE MATERIAL, AFTER REWORKING, REMAINS UNSUITABLE, THEN THE ■ THIS MATERIAL AND REPLACE IT WITH AN APPROVED MATERIAL. r,r SHALL :, PROOF ROLLED WITF A FULLY LOADED TANDEM AXLE TRUCK PRIOR TO PAVING. ANY SOFT MATERIAL SHALL BE REWORKED OR REPLACED. 19. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION MANAGER THE REQUIREMENTS FOR THE LIMITS OF OVERHEAD AND OR UNDERGROUND ELECTRICAL SERVICE 20. THE CONTRACTOR•#■r • • . • OF NEW UNDERGROUND •SERVICE WITH THE TELEPHONEr THE OWNERS REQUIREMENTS. 21. ALL MATERIALS r • .. ■ r FOR ONE YEAR FROM DATE OF , 22. ALL UNDERGROUND UTILITIES (ELECTRICITY, TELEPHONE, — ETC.) SHALL BE INSTALLED • r TESTED SATISFACTORY PRIOR TO COMMENCING ANY PAVING OPERATIONS WHERE SUCH UTILITIES ARE OF PAVING. RESPONSIBLE23. THE CONTRACTOR IS RESPONSIBLE FOR APPOINTING A DESIGNATED it RESPONSIBLE LAND DISTURBER" (RLD) WHO SHALL BE • AND e ALL EROSION CONTROLMEASURES.RLD SHALL BE CERTIFIED f ILE COPY • r4 N 11 W tl Department of Planningand Developnient 540/665-5651 540/678-0682 '?'A­PC,&.�]_1iance;•, •1 Paula Figgat 1 Shenandoah . Drive • Waynesboro, VA 22980 RE: CUP ##20-99 of VA PCS Alliance; CFW Intelos, P.I.N. 42-A-332 (James L. Patton Property) Your Conditional Use Permit, #20-99 for a 140-foot, 'monopole Commercial Telecommunicatioi Facility� was approved with a waiver of the setback requirements and the following conditions: All Zoning Ordinance requirements and review agency comments shall be addressed an-il complied with at aU times. The tower shall be available for locating personal wireless service providers. 3. A minor site plan is approved by the Count 4. The tower shall be removed by the applicant or landowner within twelve (12) months of the abandonment of operation. If you have any questions regarding this action, please feet free to call this office. Sincerely, �.r L Michael T. Muddy Zoning Administrator MTR/ch J cc; Commissioner of Revenue Leonard L. Greisz, Shentel 0:1AS=W\APPR DEN.L'MNM P' WFBVW.WnlCUP•wpd 107 North Kent Street ®Winchester, Virginia 22601-5000 Draper `' Associates Engineering „-eEnvir-onimentalSes-vim �� IT. 1 � � ti • . r, Richmond, Charlottesville, : • • : Hampton Roads, A 1 ..Raleigh -Durham, NC 1. l�l�, % .•, ,f • '1'1. ° ; S ..1 7.f r` s DESCRIPTION .. i 1 ti� 71 1 • .... 1 «I •7• • 7 •• 7• •1 7, 1 1 SITE NO: VA259P x 15 CHECKED BY: TKD 10i» UA IJL f I% DI I f W�, SITE: VA259P WEST WINCHESTER 294 FOOTSTONE SHEET NUMBER: C4 JOBI R04724 LSL'ii� 1 REAR WALL ELEVATION C EQUIPMENT SHELTER SHOWN R ELECTRICAL,REPRESENTATIVE PURPOSES ONLY. REFER TO MANUFACTURER INFORMATION AND/OR ARCHITECTURALI I,'. STRUCTURAL DRAWINGS . OTHERS. SMELTER -■ ELEVATIONS DRAWINGS .. VFP, INC., PLAN NUMBER VFPI-7. LL REr n LL m IT'D' i . I u1m, ml, NOTTO SCALE xw:hw0,1 Draper ' Aden Associates Engineering„_, SEAL: WEST WINCHESTIER 22603 SHEET NUMBER: JOB# R04724 �'�'°� .. � - � 'y r�� �\ ,. -:,a - _ `k r 0 i 0 r- � CONCR[ S1 NOT TO SCAU SEE S-2 FOR SLAB ELEVATIONS 3/4"x45' CHAMFER (TYP.) 4'x4'x4" THICK SLAB AT DOOR LOCATION SLOPE 1 /4" PER FOOT AWAY FROM SHELTER 3" f] U O 1O ° BUILD UP AREA UNDER STOOP WITH GRAVEL _ III --III a PREFORMED EXPANSION JOINT _ MATERIAL 20'-0" CENTERLINE OF CONCRETE STOOP EQUALS CENTERLINE OF SHELTER DOOR THE FINISHED CONCRETE PROFILE SHALL COMPLY WITH THE FOLLOWING FLATNESS AND LEVELNESS VALUES: SPECIFIED MINIMUM OVERALL LOCAL FLATNESS: 25 15 LEVELNESS: 20 10 WELDED WIRE FABRIC 6x6-W1.4xW1.4 4 - Q ° �C X X X X X X X . 4 0 I I I — Q Q N< -III w w w - �' FAJ N 0 Q X---°XI ZI-X--- ,X . 4 m 00 6" MINIMUM COMPACTED CRUSHED AGGREGATE 4" MINIMUM ABOVE FINISHED GRAVEL SURFACE 6" MINIMUM SLAB #4 CONTINUOUS LONGITUDINAL BARS -III I I III III II F III_ I III III III III III i 3" 12" 3" 6" MINIMUM 2 CONCRETE FOOTING S 18" S1 NOT TO SCALE MINIMUM STRUCTURAL NOTES GENERAL 1. FOUNDATION DESIGN BASED ON 2000 PSF ALLOWABLE SOIL BEARING CAPACITY. IF OTHER CONDITIONS EXIST, FOUNDATION SHALL BE REDESIGNED. CONTRACTOR SHALL HAVE SOIL BEARING CAPACITY VERIFIED BY A LICENSED PROFESSIONAL GEOTECHNICAL ENGINEER PRIOR TO INITIATION OF CONSTRUCTION ACTIVITIES. IF ALLOWABLE SOIL BEARING IS LESS, FOUNDATION SHALL. BE RE —ENGINEERED. 2. SLAB TYPE FOUNDATION IS NOT RECOMMENDED FOR AREAS WITH EXTREME FROST CONDITIONS OR WHERE HIGH WATER TABLES ARE PRESENT. THESE CONDITIONS COULD CAUSE DIFFERENTIAL SETTLEMENTS IN THE SOIL BENEATH THE FOUNDATION RESULTING IN STRUCTURE CRACKS. 3. PERIMETER FOOTING SHALL BE A MINIMUM FOUNDATION DEPTH NOT LESS THAN THE REQUIREMENT FOR LOCAL FROST LINE CONDITIONS. 4. ALL BACKFILL SHALL BE THOROUGHLY COMPACTED TO A MINIMUM OF 95% MODIFIED PROCTOR DENSITY. MATERIALS 1. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI 28 DAYS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE AD-318-B3 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. 2. REINFORCING BARS SHALL CONFORM TO ASTM—A615-132 GRADE 60 SPECIFICATIONS AND BE DETAILED IN ACCORDANCE WITH AD-318-133. 3. TEST CYLINDERS SHALL BE MOLDED AND LABORATORY CURED IN ACCORDANCE WITH ASTM C31. THREE CYLINDERS SHALL BE TAKEN FOR EACH DAY'S CONCRETE PLACEMENT. CYLINDERS SHALL BE TESTED IN ACCORDANCE WITH ASTM C39. TOLERANCES 1. TOP OF CONCRETE FOUNDATION MUST BE WITHIN 0.02" (6.09) OF ELEVATION SPECIFIED. Draper Aden Associates Engineering • Surveying • Environmental Services 8090 Villa Park Drive Blacksburg, VA Richmond, VA 23228 Charlottesville, VA 804-264-2228 Hampton Roads, VA Fax: 804-264-8773 Raleigh -Durham, NC www.daa.com NEXTEL PARTNERS, INC. 5115 BERNARD DRIVE, SUITE 200 ROANOKE, VA 24018 SEAL: AiRvw o 0 L N06 029422, .rz nl:ir SUBMITTALS/REVISIONS NO. DESCRIPTION DATE 1 LEASE EXHIBIT ISSUED FOR APPROVAL 12/22/04 2 CONSTRUCTION DRAWINGS ISSUED FOR REVIEW 01/28/05 3 CD'S REV. PER NEXTEL PARTNERS COMMENTS 02/11/05 4 5 6 7-1 SITE NO: VA259P DRAWN BY: JJF CHECKED BY: DWS SCALE: AS NOTED TITLE: STRUCTURAL FOUNDATION PLAN, DETAILS AND NOTES SITE: VA259P WEST WINCHESTER 294 FOOTSTONE LANE WINCHESTER VA, 22603 SHEET NUMBER: S1 JOB# R04724