HomeMy WebLinkAbout28-04 Premier Reticles, LTD. - Office & Manufacturing - Back Creek - Backfile1. COVER ■ GENERAL2. NOTES 3. SITE PLAN LEGEND EXISTING PROPOSED BOUNDARY & R/W! LINE ------ _...... _._...._. EASEMENT LINE ---------------- -_ EDGE PAVEMENT CENTERLINE _.._........ _ FENCE LINE x x RAILROAD GAS LINE G G OVERHEAD ELECTRIC OHE OHE UNDERGROUND ELECTRIC LINE UGE UGE OVERHEAD TELEPHONE LINE OHT —GHT - --------- UNDERGROUND TELEPHONE LINE UGE UGE p ROADSIDE DELINEATORS a a o a a GUARDRAIL OR -{t;r TRAFFIC BARRICADE W/ATER MAIN POP. >3■ W! M 1JA BUILDINGS _- _ -._ ___. RETAINING WALL Y iV SIDEWALK ,tr m mo .. ASPHALT TRAIL HEADER CURB t.x 4 t CURB & GUTTER a CG-6R ., . SANITARY SEWER 13" SAN 15" RCP STORM SEWER _...._. -- DITCH. SWALE OR- - SMALL STREAM CONCRETE DITCH TREES l LIMITS OF CLEARING & GRADING (DRIP LINE OF TREES) _.._ LIMITS OF GRADING ®—®®®®®—®®® ;. ...... _ ._..._... CONTOUR LINE 390 SPOT ELEVATION X425 S'HAWNEE MAGISTERIAL DISTRICT r... COUNTY7 T�^'�" sl .� , ,� t VIRGINIA OWNER/APPLICANT William I�. Gordon &1-1.4 Associates, Inc. Engineers -Land Planners -Landscape Architects -Surveyors 24 West Piccadilly Street, Suite A Winchester, Virginia 22601 (540) 542-1737 FAX (540) 542-1923 PROJECT MANAGER: SCOTT STICKLEY, P.E. APPROVAL BLOCK SITE PLAN VALID FOR FIVE (5) YEARS FROM APPROVAL DATE - 2 U�w COUNTY ZONING ADMINISTRATOR DATE MICHAEL S. TI!CI LIC NS PIo. �®� 031162 a VICINITY MA SCALE:1 "=1000' SHEET 1 OF 3 �f� ,. Od` ti ��� f �,,o� N � 4; n, ��., ��� ,;rr� � �� 1. THE PROPERTY DELINEATED ON THIS PLAN IS LOCATED ON TAX MAP 75 - ((A)) - 91 G. 2. THE EXISTING TOPOGRAPHIC INFORMATION SHOWN HEREON WAS PREPARED BY WILLIAM H. GORDON ASSOCIATES, INC. APRIL 2004. CONTOUR INTERVAL IS TWO FEET. 3. THE BOUNDARY INFORMATION IS TAKEN FROM AVAILABLE RECORDS. 4. ALL SPOT SHOTS ARE TO THE TOP OF CURB OR FINISHED GRADE UNLESS OTHERWISE NOTED. 5. SEE COVER SHEET FOR LEGEND OF SYMBOLS USED HEREON. 6. CHANGES OR REVISIONS IN CONSTRUCTION PLANS AND SPECIFICATIONS SHALL NOT BE MADE UNLESS FIRST APPROVED BY THE FREDERICK COUNTY DEPARTMENT OF PLANNING AND DEVELOPMENT AND/OR OTHER REGULATORY AGENCIES. 7. A PREVIOUS SITE PLAN FOR THIS PROPERTY WAS PREPARED BY GREENWAY ENGINEERING, DATED JANUARY 1, 2000, FOR THE EXISTING BUILDING AND PARKING LOT. 1. DEVELOPMENT OF THE SITE INCLUDING CONSTRUCTION AND MATERIALS WILL BE IN CONFORMANCE WITH CURRENT FREDERICK COUNTY AND/OR VIRGINIA DEPARTMENT OF TRANSPORTATION STANDARDS AND SPECIFICATIONS. 2. EROSION AND SEDIMENT CONTROL DEVICES TO BE IN PLACE PRIOR TO ANY CONSTRUCTION. REFER TO EROSION AND SEDIMENT CONTROL PLAN FOR PHASING AND DETAILS. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE OWNER AND THE ENGINEER OF ANY CHANGES OR CONDITIONS ATTACHED TO PERMITS REQUIRED FOR CONSTRUCTION. 4. THE CONTRACTOR SHALL PROVIDE ADEQUATE MEANS OF CLEANING TRUCKS AND/OR EQUIPMENT OF MUD AND DEBRIS, PRIOR TO ENTERING STATE RIGHT-OF-WAY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CLEAN STREETS OF MUD AND/OR LAYING DUST AND TO TAKE ALL APPROPRIATE MEASURES NECESSARY TO ENSURE THAT STREETS ARE KEPT IN A CLEAN AND DUST FREE CONDITION AT ALL TIMES. 5. THE CONTRACTOR SHALL VISIT THE SITE AND SHALL VERIFY EXISTING CONDITIONS PRIOR TO STARTING CONSTRUCTION ACTIVITIES. 6. THE CONTRACTOR SHALL CLEAR THE SITE OF ALL TREES, BUILDINGS, FOUNDATIONS, ETC. WITHIN THE LIMITS OF CONSTRUCTION C ON AND SHALL BE RESPONSIBLE FOR COORDINATING ANY DISCONNECTION AND 0R ABANDONMENT OF EXISTING UTILITIES. / S NG UT LIT ES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND ABANDONING ALL EXISTING WELLS AND/OR SEPTIC DRAIN FIELDS AND COORDINATING THEIR ABANDONMENT WITH THE HEALTH DEPARTMENT, 7. ALL LAND ON OR OFF -SITE WHICH IS DISTURBED BY CONSTRUCTION AND WHICH IS NOT BUILT UPON OR SURFACED, SHALL BE ADEQUATELY STABILIZED TO CONTROL EROSION AND SEDIMENTATION. 8. CONTACT "MISS UTILITY" AT 1-800-552-7001 A MINIMUM OF 72 HOURS PRIOR TO ANY EXCAVATION WITHIN PUBLIC RIGHT-OF-WAYS OR WITHIN AREAS SERVED BY UNDERGROUND UTILITIES. THE CONTRACTOR 1S RESPONSIBLE FOR FIELD VERIFYING THE PRESENCE OF ANY UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 9. WILLIAM H. GORDON ASSOCIATES, INC. DOES NOT CERTIFY TO THE LOCATION OF OR THE EXISTENCE OF ANY EXISTING UNDERGROUND UTILITIES. ANY UNDERGROUND UTILITIES SHOWN HEREON ARE BASED UPON AVAILABLE RECORDS AND DISCUSSION WITH THE OWNER. THIS DOES NOT CONSTITUTE A GUARANTEE OF THEIR ACTUAL LOCATIONS OR THAT THEY HAVE ALL BEEN SHOWN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DIGGING OF TEST HOLES PRIOR TO BEGINNING ANY CONSTRUCTION. THESE TEST HOLES WILL BE MADE TO VERIFY ALL CROSSINGS BETWEEN NEW AND EXISTING FACILITIES AND AT CRITICAL GRADE CHANGES. IF CONDITIONS ARE FOUND IN THE FIELD, WHICH ARE MATERIALLY DIFFERENT FROM THE PLANS, THE CONTRACTOR SHALL NOTIFY WILLIAM H. GORDON ASSOCIATES, INC. SO THAT APPROPRIATE REVISIONS IF WARRANTED CAN BE MADE TO THE PLANS. 10. CONTROLLED FILLS AND SUB GRADES: A) CONTROLLED COMPACTION SHALL OCCUR IN ALL FILL SECTIONS FOR PAVEMENT, TRENCHES FOR UTILITIES, AND IN ANY AREA OTHERWISE DESIGNATED ON THE DRAWINGS. B) CONTROLLED FILLS SHALL BE COMPACTED TO A MINIMUM OF 95% DENSITY AS DETERMINED BY METHODS AS PER STANDARD PROCTOR AASHTO - T99 EXCEPT THE UPPER EIGHT (8) INCHES OF SOILS BELOW THE PAVEMENT SUB BASE STONE, WHICH SHALL BE COMPACTED TO 100% OF THIS STANDARD AS DIRECTED BY A QUALIFIED GEOTECHNICAL ENGINEER. C) CONTROLLED FILL SHALL BE COMPACTED IN EIGHT (8) INCH LIFTS (LOOSE THICKNESS) TO THE SPECIFIED DENSITY, BEGINNING FROM THE EXISTING GROUND SURFACE, UNLESS OTHERWISE APPROVED IN WRITING BY A QUALIFIED GEOTECHNICAL ENGINEER. 11. ALL TESTS, STUDIES, ETC., REQUIRED DURING CONSTRUCTION WILL BE CARRIED OUT BY THE CONTRACTOR. 12. THE APPROVAL OF THESE PLANS SHALL IN NO WAY RELIEVE THE OWNER OF COMPLYING WITH OTHER APPLICABLE LOCAL, STATE AND FEDERAL REQUIREMENTS. 13. CONSTRUCTION BLASTING IS LIMITED BETWEEN THE HOURS OF 8:00 AM TO 5:00 PM OR AS OTHERWISE PERMITTED. 14. ALL PROPOSED ELEVATIONS AS SHOWN HEREIN ARE FINISHED GRADE UNLESS OTHERWISE NOTED. 15. MAINTAIN A MINIMUM VERTICAL CLEARANCE OF ONE (1) FOOT SIX (6) INCHES BETWEEN CROSSING OF ALL UTILITIES LINES UNLESS OTHERWISE NOTED. 16. CBR TEST SHALL BE PERFORMED PRIOR TO DETERMINATION OF FINAL SUB GRADE ELEVATION FOR PAVEMENT AREAS. SOILS TESTS OF SUB GRADE MUST BE SUBMITTED FOR ACTUAL DETERMINATION OF REQUIRED SUB BASE THICKNESS PRIOR TO STRUCTION. ALL SUB GRADE TO BE COMPACTED TO 95% DENSITY AT 20% OF OPTIMUM MOISTURE CONTENT PER AASHTO-T99 METHOD UNLESS OTHERWISE DIRECTED BY AN APPROVED GEOTECHNICAL REPORT. 17. CHANGES OR REVISIONS IN CONSTRUCTION PLANS AND SPECIFICATIONS SHALL NOT BE MADE UNLESS FIRST APPROVED BY THE COUNTY ENGINEER AND OTHER APPROPRIATE AGENCIES. V1. All work on this project shall conform to the latest editions of the Virginia Department of Transportation (VDOT) Road and Bridge Specifications and Standards, the Virginia Erosion and Sediment Control Regulations and any other state, federal or local regulations applicable. In the event of conflict between any of these standards, specifications or plans, the most stringent shall be govern. V2. All construction shall comply with the latest U.S. Department of Labor, Occupational Safety and Health Administration and VOSH Rules and Regulations. V3. When working on VDOT right-of-way, all traffic control, whether permanent or temporary, shall be in accordance with the current edition of VDOT's work area protection manual. Furthermore, all traffic control flaggers must be certified in accordance with the latest edition of the VDOT Road and Bridge Specifications, Section 104.04-C. V4. The developer shall be responsible for relocating, at his expense, any and all utilities, including traffic signal poles, junction boxes, controllers, etc. owned by VDOT or private utility company. It is the sole responsibility of the developer to locate and identify utility facilities or items, which may be in conflict with the proposed construction activity. VDOT approval of these plans does not relieve the developer of this responsibility. V5. Design features relating to field construction, regulations, and control or safety of traffic may be subject to change as deemed necessary by VDOT. Any additional expense incurred as a result of any field revision will be the responsibility of the developer. V6. Prior to initiation of work, the contractor shall be responsible for acquiring all necessary VDOT land use permits for any work on VDOT right-of-way. V7. If required by the local VDOT Residency Office, a pre -construction conference must be arranged and held by the engineer and/or developer with the attendance of the contractor, various County agencies, utility companies and VDOT prior to initiation of work. V8. The contractor shall notify the local VDOT Residency Office when work is to begin or cease for any undetermined length of time. VDOT will also require 48 hours notice for any inspection. V9. The contractor will be responsible for maintaining adequate access to the project from the adjacent public roadway through construction and maintenance of a construction entrance in accordance with the Virginia Erosion and Sediment Control Handbook, Section 3.02. Furthermore, access to other properties affected by this project shall be maintained through construction. The Developer shall have, within the limits of the project, an employee certified by the Department of Conservation and Recreation in Erosion and Sediment Control who shall inspect erosion and siltation control devices and measures for proper installation and deficiencies immediately after each rainfall, at lest daily during prolonged rainfall, and weekly when no rainfall event occurs. V10. Contractor shall ensure adequate drainage is achieved and maintained on the site during and at the end of construction. V11. All water and sewer lines within existing or proposed VDOT right-of-way are to have minimum 36" cover and, when possible, to be installed under roadway drainage facilities. V12. Any unusual subsurface conditions encountered during the course of construction shall be immediately brought to the attention of the engineer and VDOT. Work shall cease in that vicinity until an adequate design can be determined by the engineer and approved by VDOT. V13. All fill areas, borrow material and undercut areas shall be inspected and approved by a VDOT representative prior to placement and fill. Where C R testing p e B t st g is required, a VDOT representative shall be present to insure the sample obtained is representative of the location. When soil samples are submitted to private laboratories for testing, the samples shall be clearly identified and labeled as belonging to a project which will be accepted by VDOT and that testing shall be conducted according to all applicable VDOT standards. V14. All roadway fill, base, subsurface material and backfill of utility/storm sewer trenches shall be compacted in 6" lifts to 95% of theoretical maximum density as determined by AASHTO T-99 Method A, within plus or minus 2% of optimum moisture for the full width of any dedicated street right-of-way. At the direction of VDOT Inspector, density tests performed by a qualified independent agency shall be conducted as required in the VDOT Road and Bridge Specifications. A copy of all tests shall be submitted to VDOT prior to final VDOT approval. V15. VDOT Standard CD and UD under -drains shall be installed where indicated on these plans and further where determined necessary by VDOT Inspector. V16. The installation of any entrances and mailboxes within any dedicated street right-of-way shall meet VDOT minimum design standards and is the responsibility of the developer. V17. Prior to acceptance by VDOT of any streets, any required street signage and/or pavement markings must be installed by the developer or at VDOT's discretion, by VDOT on an account receivable basis. Stop signs shall be thirty (30) inches tail with high intensity sheeting. The bottom of the sign shall be six (6) feet above the edge of pavement and the post shall be installed a minimum of four (4) feet from the edge of pavement. Sign posts shall be of a type found on VDOT's approved list. A copy of this list may be obtained from the District Material Section. Contact the local VDOT Residency Office with any questions regarding sign material and placement. V18. The developer must provide to the local VDOT office a list of all material sources prior to construction. Copies of all invoices for materials within any dedicated street right-of-way must be provided to the local VDOT Residency Office prior to acceptance of the work. Unit and total prices may be obscured. V19. Aggregate bases and sub -bases shall be placed on the sub -grade by means of a mechanical spreader. Density will be determined using the density control strip as specified in VDOT's Road and Bridge Specifications -Section 304 and VTM-10. A certified compaction technician shall perform these tests. A certified copy of the test results shall be provided to the Residency Office. In additions to checking stone depths, a VDOT representative shall be notified and given the opportunity to be present during the construction and testing of the density control strip. V20. Asphalt concrete pavement shall be placed in accordance with the latest edition of VDOT's Road and Bridge Specifications -Section 315. Density will be determined using the density control strip as specified in Section 315 and VTM-76. A certified compaction technician shall perform these tests. A certified copy of the test results shall be provided to the Residency Office. A VDOT representative shall be notified and given the opportunity to be present during the construction and testing of the control strip. V21. Approval of these plans shall expire three (3) years from the date of the approval letter. V22. Final location of CG-12 Curb Ramps shall be determined by VDOT inspector. 1. THE AUTHORITY'S WATER AND SEWER STANDARDS AND SPECIFICATIONS ARE AVAILABLE AT WWW.FCSA-WATER.COM. 2. THE WATER AND SANITARY SEWER PORTION OF THESE PLANS ARE VALID FOR TWO YEARS FROM DATE OF FCSA APPROVAL. 3. WATER AND SEWER LINES ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THESE PLANS AND SHALL MEET ALL AUTHORITY REQUIREMENTS. 4. THE CONTRACTOR SHALL COORDINATE WITH, AND ARRANGE FOR INSPECTION BY, THE AUTHORITY. 5. WHEN AN EXISTING WATER MAIN IS TAPPED FOR THE INSTALLATION OF A NEW LINE: A. THE AUTHORITY SHALL FURNISH ALL LABOR AND MATERIALS. B. THE DEVELOPER/CONTRACTOR MUST: 1) MAKE APPLICATION AND PAY DEPOSIT 2) MARK THE TAP LOCATION 6. THE CONTRACTOR SHALL TIE-IN A NEW SEWER LINE TO AN EXISTING MANHOLE BY CORE DRILLING THE MANHOLE. 7. EXACT LOCATIONS OF WATER AND SEWER SERVICES ON NEW LINES ARE TO BE COORDINATED WITH THE AUTHORITY'S INSPECTOR. 8. THE AUTHORITY'S MAINTENANCE DEPARTMENT SHALL FURNISH AND INSTALL ALL WATER METERS THROUGH 2" IN SIZE. IT IS THE DEVELOPER'S/CONTRACTOR'S RESPONSIBILITY TO HAVE THE METER BOX ASSEMBLY INSTALLED CORRECTLY. BEFORE A PERMANENT METER IS INSTALLED: A. THE METER BOX, WITH ITS FRAME AND COVER, MUST BE PROPERLY ALIGNED WITH THE COPPERSETTER B. THE FRAME AND COVER SHALL BE SET TO FINAL GRADE C. THE DISTANCE BETWEEN THE TOP OF THE COVER AND THE COPPERSETTER SHALL TO BE BETWEEN 18 AND 21 INCHES D. ALL COMPONENTS OF THE METER BOX ASSEMBLY SHALL BE IN PROPER WORKING ORDER 9. FOR WATER AND SEWER SERVICES THAT CONNECT TO EXISTING LINES: A. THE LOCATION OF THE SERVICE LATERAL IS TO BE COORDINATED WITH THE AUTHORITY'S ENGINEERING ASSISTANT B. AN APPLICATION FOR SERVICE MUST BE MADE AND FEES PAID BEFORE WORK WILL BEGIN C. THE AUTHORITY SHALL FURNISH AND INSTALL ALL 5/8", 3/4" AND 1" WATER SERVICES D. FOR ALL 1 1/2" AND 2" WATER SERVICES, THE AUTHORITY SHALL MAKE THE TAP AND BRING THE PIPING TO THE PROPERTY LINE. THE CONTRACTOR SHALL FURNISH AND INSTALL THE METER VAULT ASSEMBLY. THE AUTHORITY WILL INSTALL THE METER. E. THE AUTHORITY WILL INSTALL ALL SEWER LATERALS. 10. ANY WATER SERVICE LINE MUST HAVE A BACKFLOW PREVENTION ASSEMBLY (DOUBLE CHECK VALVE OR RPZ, AS REQUIRED). THE ASSEMBLY MUST MEET ASSE STANDARD No. 1015 OR 1013. 11. ALL FIRE LINES SHALL HAVE A FIRE SERVICE METER ASSEMBLY AND A BACKFLOW PREVENTION ASSEMBLY (DETECTOR DOUBLE CHECK VALVE OR RPZ, AS REQUIRED). THE ASSEMBLY SHALL MEET ASSE NO. 1048 OR 1047. RADIO READ REMOTES ARE REQUIRED. PROJECT DESCRIPTION THE PROPERTY IS LOCATED APPROXIMATELY ONE-THIRD OF A MILE NORTH OF THE INTERSECTION OF ROUTES 37 AND 11 SOUTH OF WINCHESTER. THE SITE AREA IS 1.0 ACRES OF WHICH APPROXIMATELY 0.39 ACRES WILL BE DISTURBED FOR THIS PROJECT. THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A 6,000 SF BUILDING ADDITION. EXISTING SITE CONDITIONS THE FRONT HALF OF THE SITE WAS DEVELOPED IN 2000/2001 AND CONTAINS A 4,000 SF BUILDING, UTILITIES, PARKING AND LANDSCAPING. THE REAR HALF OF THE SITE IS CURRENTLY VACANT AND COVERED WITH GRASS. ADJACENT PROPERTY THE SITE IS BOUNDED BY COMMONWEALTH COURT TO THE SOUTH, COMMERCIAL PROPERTY TO THE EAST AND WEST AND INDUSTRIAL PROPERTY TO THE NORTH. EROSION AND SEDIMENT CONTROL MEASURES UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONSTRUCTED AND MAINTAINED ACCORDING TO THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. STRUCTURAL MEASURES PHASE I: A CONSTRUCTION ENTRANCE WITH WASH RACK (3.02) SHALL BE PROVIDED TO THE PROJECT AREA FROM THE EXISTING PARKING LOT TO MINIMIZE MUD CARRIED ONTO THE ROAD. THE CONSTRUCTION ENTRANCE SHALL REMAIN THROUGHOUT BOTH PHASES. SILT FENCE (3.05) SHALL BE INSTALLED AS SHOWN ON THE PLANS TO INTERCEPT AND DETAIN SEDIMENT AND REDUCE FLOWS ACROSS THE SITE. CHECK DAMS (3.20) SHALL BE PROVIDED AS INDICATED ON THE PLANS TO FILTER RUNOFF FROM DISTURBED AREAS PRIOR TO IT LEAVING THE SITE. TEMPORARY SEEDING (3.31) AND/OR PERMANENT SEEDING (3.32) SHALL BE PLACED ON ALL CRITICAL SLOPES (3:1 OR GREATER) AND AS NEEDED TO STABILIZE DISTURBED AREAS. PHASE II: ALL CONTROLS INSTALLED IN PHASE I TO REMAIN FOR THE DURATION OF THE PROJECT. TEMPORARY SEEDING (3.31) AND/OR PERMANENT SEEDING (3.32) SHALL BE PLACED ON ALL CRITICAL SLOPES (3:1 OR GREATER) AND AS NEEDED TO STABILIZE DISTURBED AREAS. VEGETATIVE MEASURES PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN (7) DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN (7) DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN FOURTEEN (14) DAYS. PERMANENT SOIL STABILIZATION SHALL BE APPLIED TO ALL AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN SIX (6) MONTHS. TOPSOIL THAT HAS BEEN STOCKPILED SHALL BE SURROUNDED WITH SILT FENCE AND PROTECTED BY MULCH AND/OR TEMPORARY VEGETATION IMMEDIATELY AFTER GRADING. ALL EARTH BERMS, DIVERSIONS AND SEDIMENT TRAP EMBANKMENTS ARE TO BE MACHINE -COMPACTED, SEEDED AND MULCHED (HAY MULCH OR STRAW) FOR TEMPORARY AND/OR PERMANENT VEGETATIVE COVER WITHIN FNE (5) DAYS AFTER GRADING. MANAGEMENT STRATEGIES CONSTRUCTION SHALL BE SEQUENCED SUCH THAT GRADING OPERATIONS WILL BEGIN AND END AS QUICKLY AS POSSIBLE. THE SITE SUPERINTENDENT SHALL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION AND SEDIMENT CONTROL MEASURES. MAINTENANCE OF THESE MEASURES THROUGHOUT THE PROJECT ARE CRITICAL TO THE EFFECTIVENESS OF THE PROGRAM. AFTER AREAS ABOVE CONTROLS HAVE BEEN STABILIZED, THE CONTROLS SHALL BE CLEANED UP AND REMOVED. ELECTRIC POWER, TELEPHONE, STORM, SANITARY, WATER & GAS SUPPLY TRENCHES ARE TO BE COMPACTED, SEEDED AND MULCHED WITHIN FIVE (5) DAYS AFTER BACKFILLING. NO MORE THAN 500 FEET ARE TO BE OPEN AT ANY ONE TIME. ALL CUT AND FILL SLOPES ARE TO BE SEEDED AND MULCHED WITHIN FIVE (5) DAYS OF COMPLETION OF GRADING. DRAINAGE SWALES SHALL BE STABILIZED WITH CHECK DAMS UNTIL VEGETATION HAS BEEN WELL ESTABLISHED, AT WHICH TIME THE CHECK DAMS SHALL BE REMOVED. DEVICES LISTED ABOVE ARE CONSIDERED MINIMUM EROSION AND SEDIMENT CONTROLS. ADDITIONAL CONTROL MEASURES MAY BE NECESSARY DUE TO CONTRACTOR PHASING OR OTHER UNFORESEEN CONDITIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADDITIONAL MEASURES TO THOSE SHOWN, AS NEEDED, IN ORDER TO CONTROL EROSION AND CONTAIN SEDIMENT ON SITE. ALL MEASURES SHALL BE INSTALLED ACCORDING TO THE STANDARDS AND SPECIFICATIONS IN THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. MAINTENANCE ALL CONTROL MEASURES SHALL BE INSPECTED DAILY BY THE SITE SUPERINTENDENT OR HIS REPRESENTATIVE AND WITHIN 24 HOURS AFTER ANY STORM EVENT GREATER THAN 0.5 INCHES OF RAIN PER 24 HOUR PERIOD. ANY DAMAGED STRUCTURAL MEASURES ARE TO BE REPAIRED BY THE END OF THE DAY. SEEDED AREAS SHALL BE CHECKED REGULARLY TO ENSURE THAT A GOOD STAND OF GRASS IS MAINTAINED. ALL AREAS SHALL BE FERTILIZED AND RESEEDED AS NEEDED UNTIL GRASS IS ESTABLISHED. TRAPPED SEDIMENT IS TO BE REMOVED AS REQUIRED TO MAINTAIN 50% TRAP EFFICIENCY AND DISPOSED OF BY SPREADING ON SITE. GRAVEL OUTLETS SHALL BE CHECKED REGULARLY FOR SEDIMENT BUILD-UP. IF THE GRAVEL OUTLET IS CLOGGED BY SEDIMENT, IT SHALL BE REMOVED AND CLEANED OR REPLACED IMMEDIATELY. THE CONTRACTOR IS RESPONSIBLE FOR KEEPING EXISTING PUBLIC ROADS IN A CLEAN, DUST AND MUD FREE, CONDITION AT ALL TIMES. PHASES OF LAND DISTURBANCE ACTIVITIES 1. CLEARING AND GRUBBING FOR SEDIMENT CONTROL DEVICES ONLY. 2. PLACEMENT OF SEDIMENT CONTROL DEVICES. 3. OBTAIN INSPECTOR'S APPROVAL PRIOR TO BEGINNING GRADING OPERATIONS. 4. CLEAR AND GRUB REMAINDER OF SITE. 5. ROUGH GRADE SITE. 7. FINAL GRADING. 8. RESTORATION AND STABILIZATION OF DISTURBED AREAS. 9. REMOVE EROSION AND SEDIMENT CONTROL MEASURES WITH THE APPROVAL OF THE INSPECTOR. SEEDING NOTES: 1. ALL PERMANENT SEEDING SHALL BE IN ACCORDANCE WITH SECTION 3.32 OF THE VESCH. 2. TOPSOIL SHALL BE SPREAD AT A MINIMUM DEPTH OF 4". 3. PULVERIZED AGRICULTURAL GRADE LIMESTONE SHALL BE INCORPORATED INTO SOIL (TOP 4-6 INCHES) AT A RATE OF 90 LBS. PER 1000 S.F. (2 TONS PER ACRE). 4. FERTILIZE WITH 10-10-10 AT A RATE OF 23 LBS. PER 1000 S.F. (1000 LBS. PER ACRE). 5. SEED MIX SHALL CONSIST OF 90% KENTUCKY 31 TALL FESUE AND 10% IMPROVED PERENNIAL RYE GRASS APPLIED AT THE RATE OF 250 LBS. PER ACRE.. 6. STRAW MULCH SHALL BE APPLIED TO ALL SEEDED AREAS AT THE RATE OF 3500 LBS. PER ACRE AND ANCHORED WITH CUTBACK, OR EMULSIFIED ASPHALT APPLIED AT A RATE OF 200 GALLONS PER ACRE. ZONING REOUIREMENTS CURRENT ZONING AND USE: B-3 OFFICE AND MANUFACTURING PROPOSED USE: OFFICE AND MANUFACTURING ZONING REQUIREMENTS: PROVIDED: LOT SIZE: 1.0 ACRE MINIMUM 1.0 AC. MINIMUM YARDS: FRONT: 35 FT MINIMUM 58.6 FT. SIDE: 15 FT MINIMUM 15.3 FT. REAR: 15 FT MINIMUM 36.6 FT. PARKING TABULATIONS: REQUIRED PARKING: OFFICE = 1 SPACE/250 S.F. = 576 S.F./250 = 3 SPACES MANUFACTURING = 3 SPACES PER 4 EMPLOYEES = 8 EMPLOYEES/4 * 3 = 6 SPACES TOTAL REQUIRED PARKING = 9 SPACES PROVIDED PARKING: EXISTING PARKING SPACES = 20 PROPOSED PARKING SPACES = NONE THERE IS NO INCREASE IN OFFICE SPACE OR EMPLOYEES WITH THIS BUILDING ADDITION. HANDICAP SPACES REQUIRED = 1 SPACE HANDICAP SPACES PROVIDED = 1 EXISTING SPACE BUILDING HEIGHT: MAXIMUM ALLOWED = 35' PROPOSED HEIGHT = 12' F.A.R. CALCULATION: F.A.R. ALLOWED = 1.0 LOT AREA = 43,560 S.F. EXISTING BUILDING = 4,000 S.F. EXISTING F.A.R. = 4,000/43,560 = 0.09 PROPOSED BUILDING = 6,000 S.F. PROPOSED F.A.R. = 10,000/43,560 = 0.23 SIGNS: ALL SIGNAGE, BUILDING MOUNTED AND FREESTANDING, SHALL REQUIRE A PERMIT FROM THE COUNTY AND COMPLY WITH THE ZONING ORDINANCE OUTDOOR LIGHTING: ALL LIGHTING SHALL BE SHIELDED TO PREVENT GLARE ON ADJOINERING PROPERTIES, RIGHT-OF-WAYS, AND APPROACHING AIRCRAFT LANDSCAPE CALCULATIONS: REQUIRED LANDSCAPING: PARKING LOT PERIMTER = 1 TREE PER 40 L.F. = 510'/40' = 13 TREES INTERIOR PARKING LOT = 1 TREE PER 10 SPACES = 20 / 10 = 2 TREES TOTAL TREES REQUIRED = 15 EXISTING LANDSCAPING: PARKING LOT PERIMETER = 15 TREES INTERIOR PARKING LOT = 2 TREES TOTAL EXISTING TREES = 17 NO ADDITIONAL TREES REQUIRED BUILDING INSPECTION DEPARTMENT NOTES: 1. BUILDING SHALL COMPLY WITH THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE AND SECTIONS 304.0 USE GROUP B (BUSINESS), 311.0 USE GROUP S (STORAGE) AND 313.0 MIX USES OF THE BOCA NATIONAL BUILDING CODE 1996. 2. ALL REQUIRED EGRESS FROM THE BUILDING SHALL COMPLY WITH A.D.A. 3. USE GROUP B, CONSTRUCTION TYPE 2C. Water/Sewer: Frederick County Sanitation Authority P.O. Box 1877 Winchester, VA. 22604 (540) 868-1061 Power: Allegheny Power P.O. Box 1458 Hagerstown, MD 21741 1-800-654-3317 Gas: Shenandoah Gas Co. P.O. Box 2400 Winchester, VA 22604 (540) 869-1111 Phone: Bell -Atlantic P.O. Box 17398 Baltimore, MD 21297 (301) 954-6282 FIRE MARSHAUS NOTE FIRE LANE MARKINGS AND SIGNAGE: Any "No Parking" signs and yellow painted curb locations will be installed by field inspection at the direction of the Fire Marshall's Office. FIRE FLOW DATA: STATIC PRESSURE _ RESIDUAL PRESSURE _ AVAILABLE FLOW = SOURCE: DATE: HYD# SURVEY N/A DESIGN MSS DRAWN MSS CHECKED MSS z w 0 v z D 0 0 It 0 Lo N F- 0 w _ 0 • C w a_ v ®Q 2 fU M ID .a. N o (/) cD N . •® N N •N ,. I w ai � z L V N CP L x D_ - Q & -> �; 0 0-� z - 1. v a),^.�r. N O • v Lo •• c (1)- o > o- n N w w z z w DATE MAY 2004 SCALE HORZ: N/A VERT: N/A SEAL TII ® CHAEL, S. $TI y IN I 031162 � TONAL JOB 2158-0101 CADD 2158nt1 SHEET 2 OF 3 a 0 0 STONE CONSTRUCTION ENTRANCE EROSION/SEDIMENT CONTROL LEGEND REVISIONS II-11=11-II-II.Il-11-1:s��+.�.! =il=n=il-n=n=u_ r.i,�.�.•..1�..1..!L..'�. ' 11=11=11=I1=11=II=��ji t+.��� . .� ��i�,,�� ��•��f a�,.�'��I, 1=Ii=11=11=11=11=11�1•• I �I �I ��il l�jl �I �I �I �I �I �I/,�: �� .•���+ •��/�� •••/r,I .•� ! I. � L'! I. • IIIIII�I II 11-11=II-11=II=�,1,' ���,'�•���,'�•���,'�•����� 1 1 FILTER CLOTH 12' MIN. SECTION A -A REINFORCED CONCRETE SECTION B-B '--DRAIN SPACE Eso-302 CONSTRUCTION OF A SILT FENCE (WITH WIRE SUPPORT) 1. SET POSTS AND EXCAVATE A eX4• 2. STAPLE WIRE FENCING TO THE POSTS. TRENCH UPSLOPE ALONG THE LINE OF POSTS. Itla FLOW 3. ATTACH THE FILTER FABRIC TO THE WIRE FENCE AND EXTEND IT INTO THE TRENCH. i FLOW 4. BACKFILL AND COMPACT THE EXCAVATED Sal. EXTENSION OF FABRIC AND WIRE INTO THE TRENCH. Adopted from Instillation of Straw and Fabric ter Barriers fa Sedanent Control i, 3" MIN. NO. KEY SYMBOL DESCRIPTION 3.02 CE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE 3.05 SF X X X SILT FENCE 3.07 IP STORM DRAIN INLET PROTECTION 3.09 DD DD TEMPORARY DIVERSION DIKE 3.10 FD TEMPORARY FILL DIVERSION 3.12 DV fir.',.- DIVERSION 3.13 ST TEMPORARY SEDIMENT TRAP 3.18 OP OUTLET PROTECTION 3.20 CD --, ----, -- CHECK DAMS 3.33 SO SO SODDING 3.38 TP 0-0-0 TREE PROTECTION LCG LIMITS OF CLEARING & GRADING DRAINAGE DIVIDES CRITICAL SLOPE - CRITICAL SLOPE TO BE SEEDED, MULCHED AND TACKED WITHIN 14 DAYS AFTER START OF GRADING, OR SODDED AND PEGGED WITHIN 14 DAYS AFTER START �i, :, ii,f•i,•i,•. . �I,.I,•I,•f,.I,if,tll,.I,.I,ffl. tll,•/,.f,�. go W-040qVir���.�r��,���� 11 RESPONSIBLE LAND DISTURBER NAME: CERTIFICATION NO.: PLATE. 3.05-1 DATE: THE RESPONSIBLE LAND DISTURBER IS THE PARTY RESPONSIBLE FOR CARRING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. f �r i lj3 r TM 75-A-91 E .: j� LOT 5 ' / P� • �`''�-�,. � s; • �r � � r( �� LETTER OF PERMISSION ZONE: BJ� t USE: OFFICE i REQUIRED FOR OFF -SITE GRADING E D i-7/'f� PROP . LOCATION FOR C D EX. TREE TO BE EITHER ��- -•r EITHER THE EX . 3" OAK i�, __ _-- -REMOVED-OR RRELOAGAfiEO EX. STM. INI�ETI,/i" --OR-NEW_2»"0AK-TREE-- L.y ay.� . _ _ ,.•,, .. °» 6�\ N 34° 16' 16" E 269.87' ' =t- 3' 1P;i_E "� `r I:.,« F [�,1 �iR "I := �.;. 47 R=32�00' I`E.I CUD — �'�IO El�fu rURI f — 15' BRL -- �i �}3 I CUT ) — — — G / H.. OPEN SPACE, 3" MAPLE _ .� EX, . 2 5' DRNG' . I SF 2T a GRASSED AREA 437 4 - 19,` R� 31 MAPLE �.' `� � xl '� \ CD \ CE'EX TREE TO REMAIN V EX. NTRr NC ! �� '-�� 1� I �. TRANS.) ° �� n r•� I O rt 2 iTRFI 4861 r.PF'ROX . LSAT iOld " ` - /1 (4 OAK ri j 4" CIA. r � j � I rs� / ,� J .� 5i ,' PROPOSED CONSTRUCTION PROP. 5'X5' 1 E GAS �. I NE EX . i�ATE -•8 > ENTRANCE W/ WASH R .� EX , I C'f�N ; ! i CK U CONC . PAD { --i METER � yr i.._-_._I _ �_ Eh`.. FIRE-. t 6 1 , 490 120' 49 490 488 I�,- NYDR ANT 4 Ir s . r� _ w_.�y - i� m /' 4 i re 3")OAK -. 80,5',' 49- EX, OVrRHE,bDI i C ,. DOC?i EX I ST I NG rt MAPLE�I ( IONE STORY I I PROP . WAREHOUSE ADDITION i - ----- I METAL BUILDING '�� BR ! C FRCS iT IGFA = 6,000 S.F. IGFA = 4,000 S,F I� HEIGHT = 12' �; HE ! GH =12 ' tom' 1 FF = 749.50 FF ELEV . 749,50 ) ry — - 6- �_ `' 1 PROP. 80' - 4" SAN. 1 >�� er ^7 J MAPLE , �' lr � � h EX. GAS METER SEW. LAT. PVC SDR-21i �� TOP OF FOUNDATION t6 2.08% I I WALL = 752.00 80.575 I 5150 5090 5060 ' 7-'�X, Sep, l C/�� PROP SAN. C/0 � 5107 �5p92 5062 15' BRL 5032 01K `t =__ _____—___� i F I I -;- m — 1 — ff S 34a--1-&' s16....W.... 331:78°,. � t� � 3"'` OP,ADFORD_PEAI2 ---- _._. " �s p SF t 3" 13PADFORO P�7?R I M 3 18R,ADFUI,D-PEAR f 3 iBRADFCI,.O-Fi< .R t. j ;- -- _ ! ' 3 8RAC FOLD PEAR � _te a. �� ��.•- � �r ��._.,..�,-214- -1 %� .. i � ,•,..,.,.,R.�.,� �'� -i .� ,.�...,.. �..�,,.,.�.b�m.� , �� _,_,_�,,..�...�.... � ,•�''� � �-_ ...�..__------ -----_...-._�____ tSRA1rFC7RD_PEAR'� -� l' IPPROX LOCATION Dim SF _ 3_.BRADFORD-.DEAR 1 EX, SAN, LAT. \ r41 r TM 75-A-91 D -°-�`'J LOT 4 ZONE: B3 USE: OFFICE 20 10 0 20 40 60 GRAPHICAL SCALE: 1 " = 20' STORMWATER MANAGEMENT NOTE: THIS SITE IS CURRENTLY SERVED BY A REGIONAL STORMWATER MANAGEMENT FACILITY LOCATED WITHIN COMMONWEALTH BUSINESS CENTER. RUNOFF FROM THE PROPOSED ADDITION FOR THE 10-YEAR STORM IS (120'X50')(6.8 IN/HR.)(0.90) = 0.84 CFS. THIS RUNOFF WILL FLOW THROUGH THE PROPOSED DITCHLINE AND TO THE EXISTING GRATE INLET LOCATED AT THE SOUTHWESTERN CORNER OF THE SITE. IT WILL THEN ENTER THE EXISTING STORM SEWER SYSTEM THAT CONVEYS FLOW TO THE EXISTING FACILITY. ENVIRONMENTAL FEATURES NOTE: THERE ARE NO KNOWN ENVIRONMENTAL FEATURES, INCLUDING STREAMS, FLOODPLAINS, LAKES AND PONDS, WETLANDS, NATURAL STORMWATER RETENTION AREAS, STEEP SLOPES AND WOODLANDS ON THIS SITE. sanitary sewer main finished grade 0 I I cleanout pipe - wye SDR 35 spigot SDR 35 spigot by by gaskefed /SDR 21 gasketed bell 45' bend / bell adapter locator peg cast iron cleanout cap with brass plug' v: oM - �. x.t :�, :�- V W.t =•w having a countersunk square head Panella Model PA4SV-CSK (4") Ponella Model PA6SV-CSK (6") SDR 21 gasketed n-; u pipe and fittings `�; 35 8"x4" square concrete skid pad gasketed bell wye 20% 20% 12" deep -A SDR 21 45' bend aggregate base ( depth 3" ) 7. 6" stone bedding NOTE Where length of service lateral to exceeds 75' a cleanout assembly shall be furnished at the property line. SEWER CLEANOUT Figure 17 ,I M cn 0 `. w . �rfl C = =� I `* 36.6 - _ p IzZpw Ipmp C Ln U) 1 (A�N-rn r 2' ninimum SCH 4Q sore` weld cap verty line R-T 18" 36" min. cover GRAVITY SEWER SERVICE LATERAL Figure 15 with ireen rn Z w 0 U z 0 U a- 0 SURVEY WHGA DESIGN MSS DRAWN MSS CHECKED MSS V) 0 w U Q , C U- U (� Q 4.0 V) (0 N C% ('4 I O ' I W��� a> - o Z c - vE o Q N x v —] a C �.•- _ > o O� z 5 .p i 0a>1)3: 3 0 - a> 0 U .� c to = In._ cn Ri N co w w z CD w DATE MAY 2004 SCALE HORZ: 1 = 20' VERT: N/A SEAL LTHI M!� V Vim✓ ICHAEE S. ST. KIL Y y ro� LIC yNSE No. 031162 �SSI�NAL �� j Z �-- O C cc Z WD (5 -cc oy J z -- Q W z F- H W 00 o Uj W W `/� Uj LL LU M co CL U W 0 a. JOB 2158-0101 CADD 2158sp1 SHEET 3 OF 3 ,,3 �_�� a �'y� � "�' � � ij;�_o ��� �� ,,, �, .. �, - � LEGEND EXISTING PROPOSED BOUNDARY & R/W LINE EASEMENT LINE ------- __....__.-_----- EDGE PAVEMENT w__._._.---_........._._.___ ....._,_._...__.. CENTERLINE FENCE LINE x x RAILROAD GAS LINE G G OVERHEAD ELECTRIC OHE OHE UNDERGROUND ELECTRIC LINE UGE -UGE OVERHEAD TELEPHONE LINE OHT ❑HT UNDERGROUND TELEPHONE LINE UGE UGE ROADSIDE DELINEATORS GUARDRAIL OR TRAFFIC BARRICADE i WATER MAIN 289P. 8" W M TO BF_ BUILDINGS �+,. ;� �a ,r ,�'ter= �^ r "n�4ACE � �� �rk.t 7..,:j �+ n �� r� ����we.' r x G m � � 4FA r c �}ti� i ��t A,. { t a A �, �'� �a���R x '�i, ti 7 i -40 Z; �« n OWNER/APPLICANT CONTRACTOR u •'! ROAD WINCHESTER, r TELEPHONE.- (540) 665-0693 William T "' f n Associates, Inc. Engineers Land Planners -Landscape Architects -Surveyors _-- _____...._.... RETAINING WALL ._. 24- West Piccadilly Street, Su ite A ..._. _ SIDEWALK Winchester, Virginia 22601 � ''i ASPHALT TRAIL _._....___._.._ ___. _.__._ . _-.. HEADER CURB (540) 54-2-1737 CURB & GUTTER ale y CG-6 TRANS CG-6R FAX (540) 5 4 2 —19 2 3 w.M yq, "7.,;.�S.wwhfrfififi'i•?h+Y?Ruw_Nk,+e r.. 'S1°:': __.-_-------- SANITARY SEWER tl SAN w..,.. ,5" RCP PROJECT MANAGER: __...__ STORM SEWER S DITCH. $WALE OR ....� �--: --- SCOTT T I C K L EY, P . E . SMALL STREAM LARGE STREAM CONCRETE DffCH APPROVAL SITE PLAN VALID FOR FIVE (5) YEARS FROM APPROVAL DATE TREES LIMITS OF CLEARING & GRADING f/J (DRIP LINE OF TREES) LIMITS OF GRADING _.. CONTOUR LINE 390 SPOT ELEVATION X425 BY THE FREDERICK COUNTY ZONING ADMINISTRATOR '2&;, '-) � DATE VICINITY A SCALE:1 "=1000' Ill SHEET 1 OF 3 .14 REVISIONS GENERAL NOTES 1. THE PROPERTY DELINEATED ON THIS PLAN IS LOCATED ON TAX MAP 75 - ((A)) - 91 G. 2. THE EXISTING TOPOGRAPHIC INFORMATION SHOWN HEREON WAS PREPARED BY WILLIAM H. GORDON ASSOCIATES, INC. APRIL 2004. CONTOUR INTERVAL IS TWO FEET. 3. THE BOUNDARY INFORMATION IS TAKEN FROM AVAILABLE RECORDS. 4. ALL SPOT SHOTS ARE TO THE TOP OF CURB OR FINISHED GRADE UNLESS OTHERWISE NOTED. 5. SEE COVER SHEET FOR LEGEND OF SYMBOLS USED HEREON. 6. CHANGES OR REVISIONS IN CONSTRUCTION PLANS AND SPECIFICATIONS SHALL NOT BE MADE UNLESS FIRST APPROVED BY THE FREDERICK COUNTY DEPARTMENT OF PLANNING AND DEVELOPMENT AND/OR OTHER REGULATORY AGENCIES. 7. A PREVIOUS SITE PLAN FOR THIS PROPERTY WAS PREPARED BY GREENWAY ENGINEERING, DATED JANUARY 1, 2000, FOR THE EXISTING BUILDING AND PARKING LOT. 1. DEVELOPMENT OF THE SITE INCLUDING CONSTRUCTION AND MATERIALS WILL BE IN CONFORMANCE WITH CURRENT FREDERICK COUNTY AND/OR VIRGINIA DEPARTMENT OF TRANSPORTATION STANDARDS AND SPECIFICATIONS. 2. EROSION AND SEDIMENT CONTROL DEVICES TO BE IN PLACE PRIOR TO ANY CONSTRUCTION. REFER TO EROSION AND SEDIMENT CONTROL PLAN FOR PHASING AND DETAILS. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE OWNER AND THE ENGINEER OF ANY CHANGES OR CONDITIONS ATTACHED TO PERMITS REQUIRED FOR CONSTRUCTION. 4. THE CONTRACTOR SHALL PROVIDE ADEQUATE MEANS OF CLEANING TRUCKS AND/OR EQUIPMENT OF MUD AND DEBRIS, PRIOR TO ENTERING STATE RIGHT-OF-WAY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CLEAN STREETS OF MUD AND/OR LAYING DUST AND TO TAKE ALL APPROPRIATE MEASURES NECESSARY TO ENSURE THAT STREETS ARE KEPT IN A CLEAN AND DUST FREE CONDITION AT ALL TIMES. 5. THE CONTRACTOR SHALL VISIT THE SITE AND SHALL VERIFY EXISTING CONDITIONS PRIOR TO STARTING CONSTRUCTION ACTIVITIES. 6. THE CONTRACTOR SHALL CLEAR THE SITE OF ALL TREES, BUILDINGS, FOUNDATIONS, ETC. WITHIN THE LIMIT S S OF CONSTRUCTION AND SHALL BE RESPONSIBLE FOR COORDINATING ANY DISCONNECTION AN/ ABANDONMENT AND/OR ABAN E OF EXISTING UTILITIES. U L ES THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND ABANDONING ALL EXISTING WELLS AND/OR SEPTIC DRAIN FIELDS AND COORDINATING THEIR ABANDONMENT WITH THE HEALTH DEPARTMENT. 7. ALL LAND ON OR OFF -SITE WHICH IS DISTURBED BY CONSTRUCTION AND WHICH IS NOT BUILT UPON OR SURFACED, SHALL BE ADEQUATELY STABILIZED TO CONTROL EROSION AND SEDIMENTATION. 8. CONTACT "MISS UTILITY" AT 1-800-552-7001 A MINIMUM OF 72 HOURS PRIOR TO ANY EXCAVATION WITHIN PUBLIC RIGHT-OF-WAYS OR WITHIN AREAS SERVED BY UNDERGROUND UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING THE PRESENCE OF ANY UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 9. WILLIAM H. GORDON ASSOCIATES, INC. DOES NOT CERTIFY TO THE LOCATION OF OR THE EXISTENCE OF ANY EXISTING UNDERGROUND UTILITIES. ANY UNDERGROUND UTILITIES SHOWN HEREON ARE BASED UPON AVAILABLE RECORDS AND DISCUSSION WITH THE OWNER. THIS DOES NOT CONSTITUTE A GUARANTEE OF THEIR ACTUAL LOCATIONS OR THAT THEY HAVE ALL BEEN SHOWN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DIGGING OF TEST HOLES PRIOR TO BEGINNING ANY CONSTRUCTION. THESE TEST HOLES WILL BE MADE TO VERIFY ALL CROSSINGS BETWEEN NEW AND EXISTING FACILITIES AND AT CRITICAL GRADE CHANGES. IF CONDITIONS ARE FOUND IN THE FIELD, WHICH ARE MATERIALLY DIFFERENT FROM THE PLANS, THE CONTRACTOR SHALL NOTIFY WILLIAM H. GORDON ASSOCIATES, INC. SO THAT APPROPRIATE REVISIONS IF WARRANTED CAN BE MADE TO THE PLANS. 10. CONTROLLED FILLS AND SUB GRADES: A) CONTROLLED COMPACTION SHALL OCCUR IN ALL FILL SECTIONS FOR PAVEMENT, TRENCHES FOR UTILITIES, AND IN ANY AREA OTHERWISE DESIGNATED ON THE DRAWINGS. B) CONTROLLED FILLS SHALL BE COMPACTED TO A MINIMUM OF 95% DENSITY AS DETERMINED BY METHODS AS PER STANDARD PROCTOR AASHTO - T99 EXCEPT THE UPPER EIGHT (8) INCHES OF SOILS BELOW THE PAVEMENT SUB BASE STONE, WHICH SHALL BE COMPACTED TO 100% OF THIS STANDARD AS DIRECTED BY A QUALIFIED GEOTECHNICAL ENGINEER. C) CONTROLLED FILL SHALL BE COMPACTED IN EIGHT (8) INCH LIFTS (LOOSE THICKNESS) TO THE SPECIFIED DENSITY, BEGINNING FROM THE EXISTING GROUND SURFACE, UNLESS OTHERWISE APPROVED IN WRITING BY A QUALIFIED GEOTECHNICAL ENGINEER. 11. ALL TESTS, STUDIES, ETC., REQUIRED DURING CONSTRUCTION WILL BE CARRIED OUT BY THE CONTRACTOR. 12. THE APPROVAL OF THESE PLANS SHALL IN NO WAY RELIEVE THE OWNER OF COMPLYING WITH OTHER APPLICABLE LOCAL, STATE AND FEDERAL REQUIREMENTS. 13. CONSTRUCTION BLASTING IS LIMITED BETWEEN THE HOURS OF 8:00 AM TO 5:00 PM OR AS OTHERWISE PERMITTED. 14. ALL PROPOSED ELEVATIONS AS SHOWN HEREIN ARE FINISHED GRADE UNLESS OTHERWISE NOTED. 15. MAINTAIN A MINIMUM VERTICAL CLEARANCE OF ONE (1) FOOT SIX (6) INCHES BETWEEN CROSSING OF ALL UTILITIES LINES UNLESS OTHERWISE NOTED. 16. CBR TEST SHALL BE PERFORMED PRIOR TO DETERMINATION OF FINAL SUB GRADE ELEVATION FOR PAVEMENT AREAS. SOILS TESTS OF SUB GRADE MUST BE SUBMITTED FOR ACTUAL DETERMINATION OF REQUIRED SUB BASE THICKNESS PRIOR TO STRUCTION. ALL SUB GRADE TO BE COMPACTED TO 95% DENSITY AT 20% OF OPTIMUM MOISTURE CONTENT PER AASHTO-T99 METHOD UNLESS OTHERWISE DIRECTED BY AN APPROVED GEOTECHNICAL REPORT. 17. CHANGES OR REVISIONS IN CONSTRUCTION PLANS AND SPECIFICATIONS SHALL NOT BE MADE UNLESS FIRST APPROVED BY THE COUNTY ENGINEER AND OTHER APPROPRIATE AGENCIES. V1. All work on this project shall conform to the latest editions of the Virginia Department of Transportation (VDOT) Road and Bridge Specifications and Standards, the Virginia Erosion and Sediment Control Regulations and any other state, federal or local regulations applicable. In the event of conflict between any of these standards, specifications or plans, the most stringent shall be govern. V2. All construction shall comply with the latest U.S. Department of Labor, Occupational Safety and Health Administration and VOSH Rules and Regulations. V3. When working on VDOT right-of-way, all traffic control, whether permanent or temporary, shall be in accordance with the current edition of VDOT's work area protection manual. Furthermore, all traffic control flaggers must be certified in accordance with the latest edition of the VDOT Road and Bridge Specifications, Section 104.04-C. V4. The developer shall be responsible for relocating, at his expense, any and all utilities, including traffic signal poles, junction boxes, controllers, etc. owned by VDOT or private utility company. It is the sole responsibility of the developer to locate and identify utility facilities or items, which may be in conflict with the proposed construction activity. VDOT approval of these plans does not relieve the developer of this responsibility. V5. Design features relating to field construction, regulations, and control or safety of traffic may be subject to change as deemed necessary by VDOT. Any additional expense incurred as a result of any field revision will be the responsibility of the developer. V6. Prior to initiation of work, the contractor shall be responsible for acquiring all necessary VDOT land use permits for any work on VDOT right-of-way. V7. If required by the local VDOT Residency Office, a pre -construction conference must be arranged and held by the engineer and/or developer with the attendance of the contractor, various County agencies, utility companies and VDOT prior to initiation of work. V8. The contractor shall notify the local VDOT Residency Office when work is to begin or cease for any undetermined length of time. VDOT will also require 48 hours notice for any inspection. V9. The contractor will be responsible for maintaining adequate access to the project from the adjacent public roadway through construction and maintenance of a construction entrance in accordance with the Virginia Erosion and Sediment Control Handbook, Section 3.02. Furthermore, access to other properties affected by this project shall be maintained through construction. The Developer shall have, within the limits of the project, an employee certified by the Department of Conservation and Recreation in Erosion and Sediment Control who shall inspect erosion and siltation control devices and measures for proper installation and deficiencies immediately after each rainfall, at lest daily during prolonged rainfall, and weekly when no rainfall event occurs. V10. Contractor shall ensure adequate drainage is achieved and maintained on the site during and at the end of construction. V11. All water and sewer lines within existing or proposed VDOT right-of-way are to have minimum 36" cover and, when possible, to be installed under roadway drainage facilities. V12. Any unusual subsurface conditions encountered during the course of construction shall be immediately brought to the attention of the engineer and VDOT. Work shall cease in that vicinity until an adequate design can be determined by the engineer and approved by VDOT. V13. All fill areas, borrow material and undercut areas shall be inspected and approved by a VDOT representative prior to placement and fill. Where CBR testing i p g s required, a VDOT representative shall be present to insure the sample obtained is representative of the location. When soil samples are submitted to private laboratories for testing, the samples shall be clearly identified and labeled as belonging to a project which will be accepted by VDOT and that testing shall be conducted according to all applicable VDOT standards. V14. All roadway fill, base, subsurface material and backfill of utility/storm sewer trenches shall be compacted in 6" lifts to 95% of theoretical maximum density as determined by AASHTO T-99 Method A, within plus or minus 2% of optimum moisture for the full width of any dedicated street right-of-way. At the direction of VDOT Inspector, density tests performed by a qualified independent agency shall be conducted as required in the VDOT Road and Bridge Specifications. A copy of all tests shall be submitted to VDOT prior to final VDOT approval. V15. VDOT Standard CD and UD under -drains shall be installed where indicated on these plans and further where determined necessary by VDOT Inspector. V16. The installation of any entrances and mailboxes within any dedicated street right-of-way shall meet VDOT minimum design standards and is the responsibiliity of the developer. V17. Prior to acceptance by VDOT of any streets, any required street signage and/or pavement markings must be installed by the developer or at VDOT's discretion, by VDOT on an account receivable basis. Stop signs shall be thirty (30) inches tall with high intensity sheeting. The bottom of the sign shall be six (6) feet above the edge of pavement and the post shall be installed a minimum of four (4) feet from the edge of pavement. Sign posts shall be of a type found on VDOT's approved list. A copy of this fist may be obtained from the District Material Section. Contact the local VDOT Residency Office with any questions regarding sign material and placement. V18. The developer must provide to the local VDOT office a list of all material sources prior to construction. Copies of all invoices for materials within any dedicated street right-of-way must be provided to the local VDOT Residency Office prior to acceptance of the work. Unit and total prices may be obscured. V19. Aggregate bases and sub -bases shall be placed on the sub -grade by means of a mechanical spreader. Density will be determined using the density control strip as specified in VDOT's Road and Bridge Specifications -Section 304 and V>•M-10. A certified compaction technician shall perform these tests. A certified copy of the test results shall be provided to the Residency Office. In additions to checking stone depths, a VDOT representative shall be notified and given the opportunity to be present during the construction and testing of the density control strip. V20. Asphalt concrete pavement shall be placed in accordance with the latest edition of VDOT's Road and Bridge Specifications -Section 315. Density will be determined using the density control strip as specified in Section 315 and VfM-76. A certified compaction technician shall perform these tests. A certified copy of the test results shall be provided to the Residency Office. A VDOT representative shall be notified and given the opportunity to be present during the construction and testing of the control strip. V21. Approval of these plans shall expire three (3) years from the date of the approval letter. V22. Final location of CG-12 Curb Ramps shall be determined by VDOT inspector. %.#%,,jA CONSTRUCTION N 1. THE AUTHORITY'S WATER AND SEWER STANDARDS AND SPECIFICATIONS ARE AVAILABLE AT WWW.FCSA-WATER.COM. 2. THE WATER AND SANITARY SEWER PORTION OF THESE PLANS ARE VALID FOR TWO YEARS FROM DATE OF FCSA APPROVAL. 3. WATER AND SEWER LINES ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THESE PLANS AND SHALL MEET ALL AUTHORITY REQUIREMENTS. 4. THE CONTRACTOR SHALL COORDINATE WITH, AND ARRANGE FOR INSPECTION BY, THE AUTHORITY. 5. WHEN AN EXISTING WATER MAIN IS TAPPED FOR THE INSTALLATION OF A NEW LINE: A. THE AUTHORITY SHALL FURNISH ALL LABOR AND MATERIALS. B. THE DEVELOPER/CONTRACTOR MUST: 1) MAKE APPLICATION AND PAY DEPOSIT 2) MARK THE TAP LOCATION 6. THE CONTRACTOR SHALL TIE-IN A NEW SEWER LINE TO AN EXISTING MANHOLE BY CORE DRILLING THE MANHOLE. 7. EXACT LOCATIONS OF WATER AND SEWER SERVICES ON NEW LINES ARE TO BE COORDINATED WITH THE AUTHORITY'S INSPECTOR. 8. THE AUTHORITY'S MAINTENANCE DEPARTMENT SHALL FURNISH AND INSTALL ALL WATER METERS THROUGH 2" IN SIZE. IT IS THE DEVELOPER'S/CONTRACTOR'S RESPONSIBILITY TO HAVE THE METER BOX ASSEMBLY INSTALLED CORRECTLY. BEFORE A PERMANENT METER IS INSTALLED: A. THE METER BOX, WITH ITS FRAME AND COVER, MUST BE PROPERLY ALIGNED WITH THE COPPERSETTER B. THE FRAME AND COVER SHALL BE SET TO FINAL GRADE C. THE DISTANCE BETWEEN THE TOP OF THE COVER AND THE COPPERSMER SHALL TO BE BETWEEN 18 AND 21 INCHES D. ALL COMPONENTS OF THE METER BOX ASSEMBLY SHALL BE IN PROPER WORKING ORDER 9. FOR WATER AND SEWER SERVICES THAT CONNECT TO EXISTING LINES: A. THE LOCATION OF THE SERVICE LATERAL IS TO BE COORDINATED WITH THE AUTHORITY'S ENGINEERING ASSISTANT B. AN APPLICATION FOR SERVICE MUST BE MADE AND FEES PAID BEFORE WORK WILL BEGIN C. THE AUTHORITY SHALL FURNISH AND INSTALL ALL 5/8", 3/4" AND 1" WATER SERVICES D. FOR ALL 1 1/2" AND 2" WATER SERVICES, THE AUTHORITY SHALL MAKE THE TAP AND BRING THE PIPING TO THE PROPERTY UNE. THE CONTRACTOR SHALL FURNISH AND INSTALL THE METER VAULT ASSEMBLY. THE AUTHORITY WILL INSTALL THE METER. E. THE AUTHORITY WILL INSTALL ALL SEWER LATERALS. 10. ANY WATER SERVICE LINE MUST HAVE A BACKFLOW PREVENTION ASSEMBLY (DOUBLE CHECK VALVE OR RPZ, AS REQUIRED). THE ASSEMBLY MUST MEET ASSE STANDARD No. 1015 OR 1013. 11. ALL FIRE LINES SHALL HAVE A FIRE SERVICE METER ASSEMBLY AND A BACKFLOW PREVENTION ASSEMBLY (DETECTOR DOUBLE CHECK VALVE OR RPZ, AS REQUIRED). THE ASSEMBLY SHALL MEET ASSE NO. 1048 OR 1047. RADIO READ REMOTES ARE REQUIRED. PROJECT DESCRIPTION THE PROPERTY IS LOCATED APPROXIMATELY ONE-THIRD OF A MILE NORTH OF THE INTERSECTION OF ROUTES 37 AND 11 SOUTH OF WINCHESTE:R. THE SITE AREA IS 1.0 ACRES OF WHICH APPROXIMATELY 0.39 ACRES WILL BE DISTURBED FOR THIS PROJECT. THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A 6,000 SF BUILDING ADDITION. EXISTING SITE CONDITIONS THE FRONT HALF OF THE SITE WAS DEVELOPED IN 2000/2001 AND CONTAINS A 4,000 SF BUILDING, UTILITIES, PARKING AND LANDSCAPING. THE REAR HALF OF THE SITE IS CURRENTLY VACANT AND COVERED WITH GRASS. ADJACENT PROPERTY THE SITE IS BOUNDED BY COMMONWEALTH COURT TO THE SOUTH, COMMERCIAL PROPERTY TO THE EAST AND WEST AND INDUSTRIAL PROPERTY TO THE NORTH. EROSION AND SEDIMENT CONTROL MEASURES UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONSTRUCTED AND MAINTAINED ACCORDING TO THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. STRUCTURAL MEASURES PHASE I: A CONSTRUCTION ENTRANCE WITH WASH RACK (3.02) SHALL BE PROVIDED TO THE PROJECT AREA FROM THE EXISTING PARKING LOT TO MINIMIZE MUD CARRIED ONTO THE ROAD. THE CONSTRUCTION ENTRANCE SHALL REMAIN THROUGHOUT BOTH PHASES. SILT FENCE (3.05) SHALL BE INSTALLED AS SHOWN ON THE PLANS TO INTERCEPT AND DETAIN SEDIMENT AND REDUCE FLOWS ACROSS THE SITE. CHECK DAMS (3.20) SHALL BE PROVIDED AS INDICATED ON THE PLANS TO FILTER RUNOFF FROM DISTURBED AREAS PRIOR TO IT LEAVING THE 'SITE. TEMPORARY SEEDING (3.31) AND/(OR PERMANENT SEEDING (3.32) SHALL BE PLACED ON ALL CRITICAL SLOPES (3:1 OR GREATER) AND AS NEEDED TO STABILIZE DISTURBED AREAS. PHASE II: ALL CONTROLS INSTALLED IN PHASE I TO REMAIN FOR THE DURATION OF THE PROJECT. TEMPORARY SEEDING (3.31) AND/OR PERMANENT SEEDING (3.32) SHALL BE PLACED ON ALL CRITICAL SLOPES (3:1 OR GREATER) AND AS NEEDED TO STABILIZE DISTURBED AREAS. VEGETATIVE MEASURES PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN (7) DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN (7) DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN FOURTEEN (14) DAYS. PERMANENT SOIL STABILIZATION SHALL BE APPLIED TO ALL AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN SIX (6) MONTHS. TOPSOIL THAT HAS BEEN STOCKPILED SHALL BE SURROUNDED WITH SILT FENCE AND PROTECTED BY MULCH AND/OR TEMPORARY VEGETATION IMMEDIATELY AFTER GRADING. ALL EARTH BERMS, DIVERSIONS AND SEDIMENT TRAP EMBANKMENTS ARE TO BE MACHINE -COMPACTED, SEEDED AND MULCHED (HAY MULCN OR S1fRAW) FOR TEMPORARY AND/OR PERMANENT VEGETATIVE COVER WITHIN FIVE (5) DAYS AFTER GRADING. MANAGEMENT STRATEGIES CONSTRUCTION SHALL BE SEQUENCED SUCH THAT GRADING OPERATIONS WILL BEGIN AND END AS QUICKLY AS POSSIBLE. THE SITE SUPERINTENDENT SHALL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION AND SEDIMENT CONTROL MEASURES. MAINTENANCE OF THESE MEASURES THROUGHOUT THE PROJECT ARE CRITICAL TO THE EFFECTIVENESS OF THE PROGRAM. AFTER AREAS ABOVE CONTROLS HAVE BEEN STABILIZED, THE CONTROLS SHALL BE CLEANED UP AND REMOVED. ELECTRIC POWER, TELEPHONE, STORM, SANITARY, WATER & GAS SUPPLY TRENCHES ARE TO BE COMPACTED, SEEDED AND MULCHED WITHIN FIVE (5) DAYS AFTER BACKFILLING. NO MORE THAN 500 FEET ARE TO BE OPEN AT ANY ONE TIME. ALL CUT AND FILL SLOPES ARE TO BE SEEDED AND MULCHED WITHIN FIVE (5) DAYS OF COMPLETION OF GRADING. DRAINAGE SWALES SHALL BE STABILIZED WITH CHECK DAMS UNTIL VEGETATION HAS BEEN WELL ESTABLISHED, AT WHICH TIME THE CHECK DAMS SHALL BE REMOVED. DEVICES USTED ABOVE ARE CONSIDERED MINIMUM EROSION AND SEDIMENT CONTROLS. ADDITIONAL CONTROL MEASURES MAY NECESSARY BE ECESSAR DUE TO CONTRACTOR PHASING OR OTHER UNFORESEEN CONDITIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADDITIONAL MEASURES TO THOSE SHOWN, AS NEEDED, IN ORDER TO CONTROL EROSION AND CONTAIN SEDIMENT ON SITE. ALL MEASURES SHALL BE INSTALLED ACCORDING TO THE STANDARDS AND SPECIFICATIONS IN THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. MAINTENANCE ALL CONTROL MEASURES SHALL BE INSPECTED DAILY BY THE SITE SUPERINTENDENT OR HIS REPRESENTATIVE AND WITHIN 24 HOURS AFTER ANY STORM EVENT GREATER THAN 0.5 INCHES OF RAIN PER 24 HOUR PERIOD. ANY DAMAGED STRUCTURAL MEASURES ARE TO BE REPAIRED BY THE END OF THE DAY. SEEDED AREAS SHALL BE CHECKED REGULARLY TO ENSURE THAT A GOOD STAND OF GRASS IS MAINTAINED. ALL AREAS SHALL BE FERTILIZED AND RESEEDED AS NEEDED UNTIL GRASS IS ESTABLISHED. TRAPPED SEDIMENT IS TO BE REMOVED AS REQUIRED TO MAINTAIN 50% TRAP EFFICIENCY AND DISPOSED OF BY SPREADING ON SITE. GRAVEL OUTLETS SHALL BE CHECKED REGULARLY FOR SEDIMENT BUILD-UP. IF THE GRAVEL OUTLET IS CLOGGED BY SEDIMENT, IT SHALL BE REMOVED AND CLEANED OR REPLACED IMMEDIATELY. THE CONTRACTOR IS RESPONSIBLE FOR KEEPING EXISTING PUBLIC ROADS IN A CLEAN, DUST AND MUD FREE, CONDITION AT ALL TIMES. PHASES OF LAND DISTURBANCE ACTIVITIES 1. CLEARING AND GRUBBING FOR SEDIMENT CONTROL DEVICES ONLY. 2. PLACEMENT OF SEDIMENT CONTROL DEVICES. 3. OBTAIN INSPECTOR'S APPROVAL PRIOR TO BEGINNING GRADING OPERATIONS. 4. CLEAR AND GRUB REMAINDER OF SITE. 5. ROUGH GRADE SITE. 7. FINAL GRADING. 8. RESTORATION AND STABILIZATION OF DISTURBED AREAS. 9. REMOVE EROSION AND SEDIMENT CONTROL MEASURES WITH THE APPROVAL OF THE INSPECTOR. SEEDING NOTES: 1. ALL PERMANENT SEEDING SHALL BE IN ACCORDANCE WITH SECTION 3.32 OF THE VESCH. 2. TOPSOIL SHALL BE SPREAD AT A MINIMUM DEPTH OF 4". 3. PULVERIZED AGRICULTURAL GRADE LIMESTONE SHALL BE INCORPORATED INTO SOIL (TOP 4-6 INCHES) AT A IRATE OF 90 LBS. PER 1000 S.F. (2 TONS PER ACRE). 4. FERTILIZE WITH 10-10-10 AT A RATE OF 23 LBS. PER 1000 S.F. (1000 LBS. PER ACRE). 5. SEED MIX SHALL CONSIST OF 90% KENTUCKY 31 TALL FESUE AND 10% IMPROVED PERENNIAL RYE GRASS APPLIED AT THE RATE OF 250 LBS. PER ACRE. 6. STRAW MULCH SHALL BE APPLIED TO ALL SEEDED AREAS AT THE RATE OF 3500 LBS, PER ACRE AND ANCHORED WITH CUTBACK, OR EMULSIFIED ASPHALT APPLIED AT A RATE OF 200 GALLONS PER ACRE. ZONING REQUIREMENTS CURRENT ZONING AND USE: B-3 OFFICE AND MANUFACTURING PROPOSED USE: OFFICE AND MANUFACTURING ZONING REQUIREMENTS: PROVIDED: LOT SIZE: 1.0 ACRE MINIMUM 1.0 AC. MINIMUM YARDS: FRONT: 35 FT MINIMUM 58.6 FT. SIDE: 15 FT MINIMUM 15.3 FT. REAR: 15 FT MINIMUM 36.6 FT. PARKING TABULATIONS: REQUIRED PARKING: OFFICE = 1 SPACE/250 S.F. = 576 S.F./250 = 3 SPACES MANUFACTURING = 3 SPACES PER 4 EMPLOYEES = 8 EMPLOYEES/4 * 3 = 6 SPACES TOTAL REQUIRED PARKING = 9 SPACES PROVIDED PARKING: EXISTING PARKING SPACES = 20 PROPOSED PARKING SPACES = NONE THERE IS NO INCREASE IN OFFICE SPACE OR EMPLOYEES WITH THIS BUILDING ADDITION. HANDICAP SPACES REQUIRED = 1 SPACE HANDICAP SPACES PROVIDED = 1 EXISTING SPACE BUILDING HEIGHT: MAXIMUM ALLOWED = 35' PROPOSED HEIGHT = 12' F.A.R. CALCULATION: F.A.R. ALLOWED = 1.0 LOT AREA = 43,560 S.F. EXISTING BUILDING = 4,000 S.F. EXISTING F.A.R. = 4,000/43,560 = 0.09 PROPOSED BUILDING = 6,000 S.F. PROPOSED F.A.R. = 10,000/43,560 = 0.23 SIGNS: ALL SIGNAGE, BUILDING MOUNTED AND FREESTANDING, SHALL REQUIRE A PERMIT FROM THE COUNTY AND COMPLY WITH THE ZONING ORDINANCE OUTDOOR LIGHTING: ALL LIGHTING SHALL BE SHIELDED TO PREVENT GLARE ON ADJOINERING PROPERTIES, RIGHT-OF-WAYS, AND APPROACHING AIRCRAFT LANDSCAPE CALCULATIONS: REQUIRED LANDSCAPING: PARKING LOT PERIMTER = 1 TREE PER 40 L.F. = 510'/40' = 13 TREES INTERIOR PARKING LOT = 1 TREE PER 10 SPACES = 20 / 10 = 2 TREES TOTAL TREES REQUIRED = 15 EXISTING LANDSCAPING: PARKING LOT PERIMETER = 15 TREES INTERIOR PARKING LOT = 2 TREES TOTAL EXISTING TREES = 17 NO ADDITIONAL TREES REQUIRED BUILDING INSPECTION DEPARTMENT NOTES: 1. BUILDING SHALL COMPLY WITH THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE AND SECTIONS 304.0 USE GROUP B (BUSINESS), 311.0 USE GROUP S (STORAGE) AND 313.0 MIX USES OF THE BOCA NATIONAL BUILDING CODE 1996. 2. ALL REQUIRED EGRESS FROM THE BUILDING SHALL COMPLY WITH A.D.A. 3. USE GROUP B, CONSTRUCTION TYPE 2C. Y Water/Sewer: Frederick County Sanitation Authority P.O. Box 1877 Winchester, VA. 22604 (540) 868-1061 Power: Allegheny Power P.O. Box 1458 Hagerstown, MD 21741 1-800-654-3317 Gas: Shenandoah Gas Co. P.O. Box 2400 Winchester, VA 22604 (540) 869-1111 Phone: Bell -Atlantic P.O. Box 17398 Baltimore, MD 21297 (301) 954-6282 FIRE MAIISHAL'S NOTE FIRE LANE MARKINGS AND SIGNAGE: Any "No Parking" signs and yellow painted curb locations will be installed by field inspection at the direction of the Fire Marshall's Office. FIRE FLOW DATA: STATIC PRESSURE _ RESIDUAL PRESSURE _ AVAILABLE FLOW = SOURCE: DATE: HYD# 'A29:0049FF 07 F_ z w O U z D 0 U 0 N MSS Ln F_ C) w d w U Q V) M 0 -.1 N z aw N N 0 -N (n a) 0 O LL' _ d a) w `�"�s z o z N a, v x CL A - d _. > Q 3. z - v a> M k v N - a> Q Ln o > a> S d- > to N a® N w w z w DATE MAY 2004 SCALE HORZ: N/A VERT: N/A SEAL LTFd 0 L� �.> CHAEL S. T�I. ;�► off, LIC�NS4No. 031162 ��`�I®1VAL �yCs JOB 2158-0101 0 W CADD 2158nt1 0 SHEET 2 OF 3 Fr 0 STONE CONSTRUCTION ENTRANCE It It 111111 111111 11111111111 t"I'll.ii -------- A 71 L, T, L, T, __L1 LI ?%A gg.,l Ji I 1 FILTER CLOTH 12' MIN. SECTION A -A f 3' MIN. REINFORCED CONCRETE `-'DRAIN SPACE SECTION B-B ESD--V2 CONSTRUCTION OF A SILT FENCE (WITH WIRE SUPPORT) 1. SET POSTS AND EXCAVATE A 4X4" 2. STAPLE WIRE FENCING TO THE POSTS. TRENCH UPSLOPE ALONG THE LINE OF POSTS. C_ FLOW 3. ATTACH THE FILTER FABRIC TO THE WIRE FENCE AND EXTEND IT INTO THE TRENCH. FLOW EXCAVATED SOIL 4. BACKFILL AND COMPACT THE EXTENSION OF FABRIC AND WIRE INTO THE TRENCH, Adopted from Installation of Straw and Fabric Filter Baniers for Sediment Control W)Tt EROSION /SEDIMENT CONTROL LEGEND NO. KEY SYMBOL DESCRIPTION 3.02 TEMPORARY GRAVEL CONSTRUCTION ENTRANCE 3.05 X----X X SILT FENCE 3.07 STORM DRAIN INLET PROTECTION 3.09 TEMPORARY DIVERSION DIKE 3.10 nT TEMPORARY FILL DIVERSION 3.12 DIVERSION 3.13 TEMPORARY SEDIMENT TRAP 3.18 VIZ) OUTLET PROTECTION 3.20 CHECK DAMS 3.33 SODDING 3.38 0-0-0 TREE PROTECTION LCG LIMITS OF CLEARING & GRADING DRAINAGE DIVIDES CRITICAL SLOPE CRITICAL SLOPE TO BE SEEDED, MULCHED AND TACKED WITHIN 14 DAYS AFTER START OF GRADING, OR SODDED AND PEGGED WITHIN 14 DAYS AFTER START 10 k1l M, M, M, 01 .0-04F.'s-01 -also ESD-320-1 NAME: CERTIFICATION Ill FLA - �365-1 DATE: THE RESPONSIBLE LAND DISTURBER IS THE PARTY RESPONSIBLE FOR CARRING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. tt S /11 - EX.STM. INLET',,, LETTER OF PERMISSION o REQUIRED FOR OFF -SITE - GRADING Z� E Di PROP. LOCATION FOR C D I EITHER THE EX. 3" OAK 0 __Z- OAK- TREE----- EX. i _RAEW 17 6 n -4, 'M 75—A-91 E LOT 5 ZONE: B3 -ISE: OFF ICE EX. TREE TO BE EITHER !..REMOVED- OR --- RELOA 34- 16' 16- E 269.87' ­zi _7 77 EX S ER 47 f 4,PVL E O , TD-6 41" ;Z*% _1 I I , Q) �,�Ons k "U1 EX. R=325i. AND GSURE:�L 15' BR_ -"tL=3 03 CUT e i i I SF CD Aill jEN , rr 2 :1 T OPEN SPACE, 2"'T -_E­ MAPLE EX. 25' DRN(,, GRASSED AREA 437o,..> ' ESIMT 819 % Yl Mil >< 14, Y EX'.""TREE TO REMAIN EE EX./NTRANCEtl,EX. TRANS. s I P. 5'X5', 4- ;AK 1 1' 1� APPROX. LOCAT A 4" OAK PROPOSED CONSTRUCT30N PRO' __j EX. GAS LINE E X• W.A T E RR�- /V > ENTRANCE W/ WASH 0CK CONC. PAD METER EX. FIRE go t 4 490 120' �E- C 0'N C' . S /W J HYDRANT AK 4 EX, OVERHEADII DOOR >< EXISTING .0 9C 3" MAPLE ONE STORY i6A, PROPA WAREHOUSE ADD I T I ON METAL BUILDING C �GFA = 6 000 S F 6 0 61 48 �� rr, 1 490 8 r r1i .-.� 48 36.6- 494A T 2ZOL.4 I M Il I , ul ill I CK FR 1,IT > CD HEIGHT = 12' GFA = 4, OOOS,F. Cn FF 749.50 HEIGHT = '12' FF ELEV. 74950 'CIV C D PROP. 80' 4" SAN. 3" MAPLE TOP OF FOUNDATION f:X� GAS METER SEW LAT. PVC SDR-2111 WALL 752.00 0 2.08% 80.55 5150 /5120 5090 5060 5l 1498) 15' BRL o - 4.,, ry.PROP. SAN. C/O 07 EX, SAT C/ 0 107 5062 5032 % 5 5092 5o07 4- "310AK IF r AL 71 If �?. ) BRA1)F'0RD_.PEAR S 34"16" '1-6`W­ '334-.-7­8-'l 3 )BRADF0RD_,PEAR BRAD(pv-�T8PA.DFORD_Pll FORD -PEAR ��RADFORD PEAR 3' BPADFORD-PEAR APPROX. LCXATIOP,Il EX, SAN, LAT. t TIVI 75—A-9.11D ___,j Jv� LOT 4' ZONE: B3 USE: OFFICE 20 10 0 20 40 60 GRAPHICAL SCALE: 1" = 20' STORMWATER MANAGEMENT NOTE: THIS SITE IS CURRENTLY SERVED BY A REGIONAL STORMWATER MANAGEMENT FACILITY LOCATED WITHIN COMMONWEALTH BUSINESS CENTER. RUNOFF FROM THE PROPOSED ADDITION FOR THE THIS RUNOFF WILL FLOW THROUGH THE PROPOSED DITCHLINE AND YEtI4,R STORM IS (120'X50')(6.8 IN/HR.)(0.90) = 0.84 CFS. 10 TO THE EXISTING GRATE INLET LOCATED AT THE SOUTHWESTERN CORNER OF THE SITE. IT WILL THEN ENTER THE EXISTING STORM SEWER SYSTEM THAT CONVEYS FLOW TO THE EXISTING FACILITY. ENVIRONMENTAL FEATURES NOTE: sanitary sewer main SDR 35 spigot SDR 35 spigot by b gasketed —SOR 21 go z g454e bend bell adopter locator peg cost iron cleanout cap with brass plug �F,7 �MN, R. having a countersunk square head Poll Model PA4SV—CSK (4") Ponell Model PA6SV—CSK finished grade N SDR 21 gasketed pipe and fittings SDR 35 8x4' square concrete skid pad gasketed bell wye 21 20'1 12" deep cleanout aggregate base depth 3" l pipe SDR 21 THERE ARE NO KNOWN ENVIRONMENTAL FEATURES, INCLUDING STREAMS, FLOODPLAINS, Wye 45* bend LAKES AND PONDS, WETLANDS, NATURAL STORMWATER RETENTION AREAS, STEEP SLOPES AND WOODLANDS ON THIS SITE. 6" stone bedding NOTE Where length of service lateral to exceeds 75' a cleanout assembly shall be furnished at the property line. SEWER CLEANOUT Figure 17 `I > En 00 1171 2 2' .0 minimum SCH 4Q o�rnl wsel cap ),aperty line M-T 18" 36" min. cover GRAVITY SEWER SERVICE LATERAL Figure 15 with reen REVISIONS LIJ 2 0 0 0 SURVEY WHGA DESIGN MSS DRAWN MSS CHECKED MSS 0 lit W < < o Q C4 Z (1) Z3 CD to 0 Uzi z >< • 3� 31 0 r U C14 CL J__ • Q C: 0 - w d :i Q) > 3: U) LIJ z z LU DATE MAY 2004 SCALE HORZ: 1 20' VERT: N/ A SEAL NLi 0 V Q Ull S. ST KL "i Ll S. E 0. 0 031162 �SSIONAL Z z > z H EL Im W z 1­ :) LLJ F­ W 00 110 Ll W za LU CC U. UJM W Cc Uj 0 JOB 2158-0101 CADD 2158spl SHEET 3 OF 3 0 '1 r.. . 5 . 1. COVER SHEET 2. GENERAL NOTES 3. SITE PLAN LEGEND EXISTING PROPOSED BOUNDARY & R/W LINE EASEMENT LINE EDGE PAVEMENT CENTERLINE --- x -- x - — FENCE LINE x x }; a ;F�-i-�-l-6-i H--1 4-t 1 �i++4- RAILROAD11111111111 ------- GAS LINE G G - - ;SHE -- OHE -- OVERHEAD ELECTRIC ❑HE ❑HE UGE _r_ UGE UNDERGROUND ELECTRIC LINE UGE UGE OHT ______ G'HT __ OVERHEAD TELEPHONE LINE ❑Hr ❑HT UGE .-----UGE _ ___ UNDERGROUND TELEPHONE LINE UGE UGE o Q ROADSIDE DELINEATORS GUARDRAIL OR TRAFFIC BARRICADE WATER MAIN EROE, 8" .T� SE- ...TO 7BUILDINGS ICE P�JC � REMAIN E U RETAINING WALL e.. �. EX� IJC S /� SIDEWALK a , ?IL SPt;Amm fA �Ir,F ASPHALT TRAIL HEADER CURB CURB & GUTTER E CG-6 TRANS CG-6R l �11 " EX. SAN. SANITARY SEWER 8® SAN t 3) t4) �... `_' 3 O Ex. 1 5,r RCP 15" RCP STORM SEWER DITCH. SWALE OR �- SMALL STREAM -� CONCRETE DITCH �C�� ���t�'° OAK TREES 0 `,�/ r' . v,. „�V, -Y- ,Yl _1y1 `y .! LIMITS OF CLEARING & GRADING (DRIP LINE OF TREES) LIMITS OF GRADING — — — — — — — — — — — rr-i k,ENTER, LOT 4A 1 OWNER/APPLICANT PREMIER RETICLES, LTD. 175 COMMONWEALTH COURT WINCHESTER, VIRGINIA 22602 TELEPHONE: (540) 868-2044 CONTRACTOR CONSTRUCTION IulAf�IAGEMENT, INC. 360-2 McGHFE ROAD WINCHESTER, VIRGINIA 22603 TELEPHONE: (540) 665-0693 r y William H. Gordon Associates, Inc. Engineers -Land Planners -Landscape Architects -Surveyors 24 West Piccadilly Street, Suite A Winchester, Virginia 22601 (540) 542-1737 FAX (540) 542-1923 PROJECT MANAGER: SCOTT STICKLEY, P.E. APPROVAL BOCK SITE PLAN VALID FOR FIVE (5) YEARS FROM APPROVAL DATE L T1 ®� tAEL S. S CKI LICENSE No. 031162 i ONAL VICINITY MAP SCALE:1 m=1000' iz PO ■ w U Q a Z W W m cr CL -390 ___ -- ._._._. CONTOUR LINE 390 APPROVED BY THE FREDERICK COUNTY ZONING ADMINISTRATOR DATE 1 x42 SPOT ELEVATION OP SHEET 1 OF 3 T. IVFF— ; —L, -", RECE 1 4- i' REDE RICK C,',)J rye ae.�ra9aaEe: A r"FVELO"WENT REVISIONS GENERAL NOTES 1. THE PROPERTY DELINEATED ON THIS PLAN IS LOCATED ON TAX MAP 75 - ((A)) - 91 G. 2. THE EXISTING TOPOGRAPHIC INFORMATION SHOWN HEREON WAS PREPARED BY WILLIAM H. GORDON ASSOCIATES, INC. APRIL 2004. CONTOUR INTERVAL IS TWO FEET. 3. THE BOUNDARY INFORMATION IS TAKEN FROM AVAILABLE RECORDS. 4. ALL SPOT SHOTS ARE TO THE TOP OF CURB OR FINISHED GRADE UNLESS OTHERWISE NOTED. 5. SEE COVER SHEET FOR LEGEND OF SYMBOLS USED HEREON. 6. CHANGES OR REVISIONS IN CONSTRUCTION PLANS AND SPECIFICATIONS SHALL NOT BE MADE UNLESS FIRST APPROVED BY THE FREDERICK COUNTY DEPARTMENT OF PLANNING AND DEVELOPMENT AND/OR OTHER REGULATORY AGENCIES. 7. A PREVIOUS SITE PLAN FOR THIS PROPERTY WAS PREPARED BY GREENWAY ENGINEERING, DATED JANUARY 1, 2000, FOR THE EXISTING BUILDING AND PARKING LOT. CONSTRUCTION NOTES 1. DEVELOPMENT OF THE SITE INCLUDING CONSTRUCTION AND MATERIALS WILL BE IN CONFORMANCE WITH CURRENT FREDERICK COUNTY AND/OR VIRGINIA DEPARTMENT OF TRANSPORTATION STANDARDS AND SPECIFICATIONS. 2. EROSION AND SEDIMENT CONTROL DEVICES TO BE IN PLACE PRIOR TO ANY CONSTRUCTION. REFER TO EROSION AND SEDIMENT CONTROL PLAN FOR PHASING AND DETAILS. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE OWNER AND THE ENGINEER OF ANY CHANGES OR CONDITIONS ATTACHED TO PERMITS REQUIRED FOR CONSTRUCTION. 4. THE CONTRACTOR SHALL PROVIDE ADEQUATE MEANS OF CLEANING TRUCKS AND/OR EQUIPMENT OF MUD AND DEBRIS, PRIOR TO ENTERING STATE RIGHT-OF-WAY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CLEAN STREETS OF MUD AND/OR LAYING DUST AND TO TAKE ALL APPROPRIATE MEASURES NECESSARY TO ENSURE THAT STREETS ARE KEPT IN A CLEAN AND DUST FREE CONDITION AT ALL TIMES. 5. THE CONTRACTOR SHALL VISIT THE SITE AND SHALL VERIFY EXISTING CONDITIONS PRIOR TO STARTING CONSTRUCTION ACTIVITIES. 6. THE CONTRACTOR SHALL CLEAR THE SITE OF ALL TREES, BUILDINGS, FOUNDATIONS, ETC. WITHIN THE LIMITS OF CONSTRUCTION AND SHALL BE RESPONSIBLE FOR COORDINATING ANY DISCONNECTION AND/OR ABANDONMENT OF EXISTING UTILITIES. THE CONTRACTOR SHAL L LL BE RESPONSIBLE FOR LOCATING AND ABANDONING ALL EXISTING WELLS AND/OR SEPTIC DRAIN FIELDS AND COORDINATING THEIR ABANDONMENT WITH THE HEALTH DEPARTMENT. 7. ALL LAND ON OR OFF -SITE WHICH IS DISTURBED BY CONSTRUCTION AND WHICH IS NOT BUILT UPON OR SURFACED, SHALL BE ADEQUATELY STABILIZED TO CONTROL EROSION AND SEDIMENTATION. 8. CONTACT "MISS UTILITY" AT 1-800-552-7001 A MINIMUM OF 72 HOURS PRIOR TO ANY EXCAVATION WITHIN PUBLIC RIGHT-OF-WAYS OR WITHIN AREAS SERVED BY UNDERGROUND UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING THE PRESENCE OF ANY UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 9. WILLIAM H. GORDON ASSOCIATES, INC. DOES NOT CERTIFY TO THE LOCATION OF OR THE EXISTENCE OF ANY EXISTING UNDERGROUND UTILITIES. ANY UNDERGROUND UTILITIES SHOWN HEREON ARE BASED UPON AVAILABLE RECORDS AND DISCUSSION WITH THE OWNER. THIS DOES NOT CONSTITUTE A GUARANTEE OF THEIR ACTUAL LOCATIONS OR THAT THEY HAVE ALL BEEN SHOWN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DIGGING OF TEST HOLES PRIOR TO BEGINNING ANY CONSTRUCTION. THESE TEST HOLES WILL BE MADE TO VERIFY ALL CROSSINGS BETWEEN NEW AND EXISTING FACILITIES AND AT CRITICAL GRADE CHANGES. IF CONDITIONS ARE FOUND IN THE FIELD, WHICH ARE MATERIALLY DIFFERENT FROM THE PLANS, THE CONTRACTOR SHALL NOTIFY WILLIAM H. GORDON ASSOCIATES, INC. SO THAT APPROPRIATE REVISIONS IF WARRANTED CAN BE MADE TO THE PLANS. 10. CONTROLLED FILLS AND SUB GRADES: A) CONTROLLED COMPACTION SHALL OCCUR IN ALL FILL SECTIONS FOR PAVEMENT, TRENCHES FOR UTILITIES, AND IN ANY AREA OTHERWISE DESIGNATED ON THE DRAWINGS. B) CONTROLLED FILLS SHALL BE COMPACTED TO A MINIMUM OF 95% DENSITY AS DETERMINED BY METHODS AS PER STANDARD PROCTOR AASHTO - T99 EXCEPT THE UPPER EIGHT (8) INCHES OF SOILS BELOW THE PAVEMENT SUB BASE STONE, WHICH SHALL BE COMPACTED TO 100% OF THIS STANDARD AS DIRECTED BY A QUALIFIED GEOTECHNICAL ENGINEER. C) CONTROLLED FILL SHALL BE COMPACTED IN EIGHT (8) INCH LIFTS (LOOSE THICKNESS) TO THE SPECIFIED DENSITY, BEGINNING FROM THE EXISTING GROUND SURFACE, UNLESS OTHERWISE APPROVED IN WRITING BY A QUALIFIED GEOTECHNICAL ENGINEER. 11. ALL TESTS, STUDIES, ETC., REQUIRED DURING CONSTRUCTION WILL BE CARRIED OUT BY THE CONTRACTOR. 12. THE APPROVAL OF THESE PLANS SHALL IN NO WAY RELIEVE THE OWNER OF COMPLYING WITH OTHER APPLICABLE LOCAL, STATE AND FEDERAL REQUIREMENTS. 13. CONSTRUCTION BLASTING IS LIMITED BETWEEN THE HOURS OF 8:00 AM TO 5:00 PM OR AS OTHERWISE PERMITTED. 14. ALL PROPOSED ELEVATIONS AS SHOWN HEREIN ARE FINISHED GRADE UNLESS OTHERWISE NOTED. 15. MAINTAIN A MINIMUM VERTICAL CLEARANCE OF ONE (1) FOOT SIX (6) INCHES BETWEEN CROSSING OF ALL UTILITIES LINES UNLESS OTHERWISE NOTED. 16. CBR TEST SHALL BE PERFORMED PRIOR TO DETERMINATION OF FINAL SUB GRADE ELEVATION FOR PAVEMENT AREAS.. SOILS TESTS OF SUB GRADE MUST BE SUBMITTED FOR ACTUAL DETERMINATION OF REQUIRED SUB BASE THICKNESS PRIOR TO STRUCTION. ALL SUB GRADE TO BE COMPACTED TO 95% DENSITY AT 20% OF OPTIMUM MOISTURE CONTENT PER AASHTO-T99 METHOD UNLESS OTHERWISE DIRECTED BY AN APPROVED GEOTECHNICAL REPORT. 17. CHANGES OR REVISIONS IN CONSTRUCTION PLANS AND SPECIFICATIONS SHALL NOT BE MADE UNLESS FIRST APPROVED BY THE COUNTY ENGINEER AND OTHER APPROPRIATE AGENCIES. VDOT GENERAL NOTES V1. All work on this project shall conform to the latest editions of the Virginia Department of Transportation (VDOT) Road and Bridge Specifications and Standards, the Virginia Erosion and Sediment Control Regulations and any other state, federal or local regulations applicable. In the event of conflict between any of these standards, specifications or plans, the most stringent shall be govem. V2. All construction shall comply with the latest U.S. Department of Labor, Occupational Safety and Health Administration and VOSH Rules and Regulations. V3. When working on VDOT right-of-way, all traffic control, whether permanent or temporary, shall be in accordance with the current edition of VDOT's work area protection manual. Furthermore, all traffic control flaggers must be certified in accordance with the latest edition of the VDOT Road and Bridge Specifications, Section 104.04-C. V4. The developer shall be responsible for relocating, at his expense, any and all utilities, including traffic signal poles, junction boxes, controllers, etc. owned by VDOT or private utility company. It is the sole responsibility of the developer to locate and identify utility facilities or items, which may be in conflict with the proposed construction activity. VDOT approval of these plans does not relieve the developer of this responsibility. V5. Design features relating to field construction, regulations, and control or safety of traffic may be subject to change as deemed necessary by VDOT. Any additional expense incurred as a result of any field revision will be the responsibility of the developer. V6. Prior to initiation of work, the contractor shall be responsible for acquiring all necessary VDOT land use permits for any work on VDOT right-of-way. V7. If required by the local VDOT Residency Office, a pre -construction conference must be arranged and held by the engineer and/or developer with the attendance of the contractor, various County agencies, utility companies and VDOT prior to initiation of work. V8. The contractor shall notify the locall VDOT Residency Office when work is to begin or cease for any undetermined length of time. VDOT will also require 48 hours notice for any inspection. V9. The contractor will be responsible for maintaining adequate access to the project from the adjacent public roadway through construction and maintenance of a construction entrance in accordance with the Virginia Erosion and Sediment Control Handbook, Section 3.02. Furthermore, access to other properties affected by this project shall be maintained through construction. The Developer shall have, within the limits of the project, an employee certified by the Department of Conservation and Recreation in Erosion and Sediment Control who shall inspect erosion and siltation control devices and measures for proper installation and deficiencies immediately after each rainfall, at lest daily during prolonged rainfall, and weekly when no rainfall event occurs. V10. Contractor shall ensure adequate drainage is achieved and maintained on the site during and at the end of construction. V11. All water and sewer lines within existing or proposed VDOT right-of-way are to have minimum 36" cover and, when possible, to be installed under roadway drainage facilities. V12. Any unusual subsurface conditions encountered during the course of construction shall be immediately brought to the attention of the engineer and VDOT. Work shall cease in that vicinity until an adequate design can be determined by the engineer and approved by VDOT. V13. All fill areas, borrow material and undercut areas shall be inspected and approved by a VDOT representative prior to placement and fill. Where CBR testing is required, a VDOT representative shall be present to insure the sample obtained is representative of the location. When soil samples are submitted to private laboratories for testing, the samples shall be clearly identified and labeled as belonging to a project which will be accepted by VDOT and that testing shall be conducted according to all applicable VDOT standards. V14. All roadway fill, base, subsurface material and backfill of utility/storm sewer trenches shall be compacted in 6" lifts to 95% of theoretical maximum density as determined by AASHTO T-99 Method A, within plus or minus 2% of optimum moisture for the full width of any dedicated street right-of-way. At the direction of VDOT Inspector, density tests performed b a qualified independent agency shall be conducted as required in the VDOT Road and Bridge Specifications. p y q p 9 y q d g A copy of all tests shall be submitted to VDOT prior to final VDOT approval. V15. VDOT Standard CD and UD under -drains shall be installed where indicated on these plans and further where determined necessary by VDOT Inspectorr. V16. The installation of any entrances and mailboxes within any dedicated street right-of-way shall meet VDOT minimum design standards and is the responsibility of the developer. V17. Prior to acceptance by VDOT of any streets, any required street signage and/or pavement markings must be installed by the developer or at VDOT's discretion, by VDOT on an account receivable basis. Stop signs shall be thirty (30) inches tall with high intensity sheeting. The bottom of the sign shall be six (6) feet above the edge of pavement and the post shall be installed a minimum of four (4) feet from the edge of pavement. Sign posts shall be of a type found on VDOT's approved list. A copy of this list may be obtained from the District Material Section. Contact the local VDOT Residency Office with any questions regarding sign material and placement. V18. The developer must provide to the local VDOT office a list of all material sources prior to construction. Copies of all invoices for materials within any dedicated street right-of-way must be provided to the local VDOT Residency Office prior to acceptance of the work. Unit and total prices may be obscured. V19. Aggregate bases and sub -bases shall be placed on the sub -grade by means of a mechanical spreader. Density will be determined using the density contrail strip as specified in VDOT's Road and Bridge Specifications -Section 304 and VTM-10. A certified compaction technician shall perform these tests. A certified copy of the test results shall be provided to the Residency Office. In additions to checking stone depths, a VDOT representative shall be notified and given the opportunity to be present during the construction and testing of the density control strip. V20. Asphalt concrete pavement shall be placed in accordance with the latest edition of VDOT's Road and Bridge Specifications -Section 315. Density will be determined using the density control strip as specified in Section 315 and VTM-76. A certified compaction technician shall perform these tests. A certified copy of the test results shall be provided to the Residency Office. A VDOT representative shall be notified and given the opportunity to be present during the construction and testing of the control strip. V21. Approval of these plans shall expire three (3) years from the date of the approval letter. V22. Final location of CG-12 Curb Ramps shall be determined by VDOT inspector. FCSA CONSTRUCTION NOTES 1. THE AUTHORITY'S WATER AND SEWER STANDARDS AND SPECIFICATIONS ARE AVAILABLE AT WWW.FCSA-WATER.COM. 2. THE WATER AND SANITARY SEWER PORTION OF THESE PLANS ARE VALID FOR TWO YEARS FROM DATE OF FCSA APPROVAL. 3. WATER AND SEWER LINES ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THESE PLANS AND SHALL MEET ALL AUTHORITY REQUIREMENTS. 4. THE CONTRACTOR SHALL COORDINATE WITH, AND ARRANGE FOR INSPECTION BY, THE AUTHORITY. 5. WHEN AN EXISTING WATER MAIN IS TAPPED FOR THE INSTALLATION OF A NEW LINE: A. THE AUTHORITY SHALL FURNISH ALL LABOR AND MATERIALS. B. THE DEVELOPER/CONTRACTOR MUST: 1) MAKE APPLICATION AND PAY DEPOSIT 2) MARK THE TAP LOCATION 6. THE CONTRACTOR SHALL TIE-IN A NEW SEWER LINE TO AN EXISTING MANHOLE BY CORE DRILLING THE MANHOLE. 7. EXACT LOCATIONS OF WATER AND SEWER SERVICES ON NEW LINES ARE TO BE COORDINATED WITH THE AUTHORITY'S INSPECTOR. 8. THE AUTHORITY'S MAINTENANCE DEPARTMENT SHALL FURNISH AND INSTALL ALL WATER METERS THROUGH 2" IN SIZE. IT IS THE DEVELOPER'S/CONTRACTOR'S RESPONSIBILITY TO HAVE THE METER BOX ASSEMBLY INSTALLED CORRECTLY. BEFORE A PERMANENT METER IS INSTALLED: A. THE METER BOX, WITH ITS FRAME AND COVER, MUST BE PROPERLY ALIGNED WITH THE COPPERSETTER B. THE FRAME AND COVER SHALL BE SET TO FINAL GRADE C. THE DISTANCE BETWEEN THE TOP OF THE COVER AND THE COPPERSETTER SHALL TO BE BETWEEN 18 AND 21 INCHES D. ALL COMPONENTS OF THE METER BOX ASSEMBLY SHALL BE IN PROPER WORKING ORDER 9. FOR WATER AND SEWER SERVICES THAT CONNECT TO EXISTING LINES: A. THE LOCATION OF THE SERVICE LATERAL IS TO BE COORDINATED WITH THE AUTHORITY'S ENGINEERING ASSISTANT B. AN APPLICATION FOR SERVICE MUST BE MADE AND FEES PAID BEFORE WORK WILL BEGIN C. THE AUTHORITY SHALL FURNISH AND INSTALL ALL 5/8", 3/4" AND 1" WATER SERVICES D. FOR ALL 1 1/2" AND 2" WATER SERVICES, THE AUTHORITY SHALL MAKE THE TAP AND BRING THE PIPING TO THE PROPERTY LINE. THE CONTRACTOR SHALL FURNISH AND INSTALL THE METER VAULT ASSEMBLY. THE AUTHORITY WILL INSTALL THE METER. E. THE AUTHORITY WILL INSTALL ALL SEWER LATERALS. 10. ANY WATER SERVICE LINE MUST HAVE A BACKFLOW PREVENTION ASSEMBLY (DOUBLE CHECK VALVE OR RPZ, AS REQUIRED). THE ASSEMBLY MUST MEET ASSE STANDARD No. 1015 OR 1013. 11. ALL FIRE LINES SHALL HAVE A FIRE SERVICE METER ASSEMBLY AND A BACKFLOW PREVENTION ASSEMBLY (DETECTOR DOUBLE CHECK VALVE OR RPZ, AS REQUIRED). THE ASSEMBLY SHALL MEET ASSE NO. 1048 OR 1047. RADIO READ REMOTES ARE REQUIRED. PROJECT DESCRIPTION THE PROPERTY IS LOCATED APPROXIMATELY ONE-THIRD OF A MILE NORTH OF THE INTERSECTION OF ROUTES 37 AND 11 SOUTH OF WINCHESTER. THE SITE AREA IS 1.0 ACRES OF WHICH APPROXIMATELY 0.39 ACRES WILL BE DISTURBED FOR THIS PROJECT. THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A 6,000 SF BUILDING ADDITION. EXISTING SITE CONDITIONS THE FRONT HALF OF THE SITE WAS DEVELOPED IN 2000/2001 AND CONTAINS A 4,000 SF BUILDING, UTILITIES, PARKING AND LANDSCAPING. THE REAR HALF OF THE SITE IS CURRENTLY VACANT AND COVERED WITH GRASS. ADJACENT PROPERTY THE SITE IS BOUNDED BY COMMONWEALTH COURT TO THE SOUTH, COMMERCIAL PROPERTY TO THE EAST AND WEST AND INDUSTRIAL PROPERTY TO THE NORTH. EROSION AND SEDIMENT CONTROL MEASURES UNLESS OTHERWISE INDICATED, ALL. VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONSTRUCTED AND MAINTAINED ACCORDING TO THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. STRUCTURAL MEASURES PHASE I: A CONSTRUCTION ENTRANCE WITH (WASH RACK (3.02) SHALL BE PROVIDED TO THE PROJECT AREA FROM THE EXISTING PARKING LOT TO MINIMIZE MUD CARRIED ONTO THE ROAD. THE CONSTRUCTION ENTRANCE SHALL REMAIN THROUGHOUT BOTH PHASES. SILT FENCE (3.05) SHALL BE INSTALLED AS SHOWN ON THE PLANS TO INTERCEPT AND DETAIN SEDIMENT AND REDUCE FLOWS ACROSS THE SITE. CHECK DAMS (3.20) SHALL BE PROVIDED AS INDICATED ON THE PLANS TO FILTER RUNOFF FROM DISTURBED AREAS PRIOR TO IT LEAVING THE SITE. TEMPORARY SEEDING (3.31) AND/OR PERMANENT SEEDING (3.32) SHALL BE PLACED ON ALL CRITICAL SLOPES (3:1 OR GREATER) AND AS NEEDED TO STABILIZE DISTURBED AREAS. PHASE II: ALL CONTROLS INSTALLED IN PHASE I TO REMAIN FOR THE DURATION OF THE PROJECT. TEMPORARY SEEDING (3.31) AND/OR PERMANENT SEEDING (3.32) SHALL BE PLACED ON ALL CRITICAL SLOPES (3:1 OR GREATER) AND AS NEEDED TO STABILIZE DISTURBED AREAS. VEGETATIVE MEASURES PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN (7) DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN 7 DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL BUT I () GRADE B WILL REMAIN DORMANT FOR LONGER THAN FOURTEEN (14) DAYS. PERMANENT SOIL STABILIZATION SHALL BE APPLIED TO ALL AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN SIX (6) MONTHS. TOPSOIL THAT HAS BEEN STOCKPILED SHALL BE SURROUNDED WITH SILT FENCE AND PROTECTED BY MULCH AND/OR TEMPORARY VEGETATION IMMEDIATELY AFTER GRADING. ALL EARTH BERMS, DIVERSIONS AND SEDIMENT TRAP EMBANKMENTS ARE TO BE MACHINE -COMPACTED, SEEDED AND MULCHED (HAY MULCH OR STRAW) FOR TEMPORARY AND/OR PERMANENT VEGETATIVE COVER WITHIN FIVE (5) DAYS AFTER GRADING. MANAGEMENT STRATEGIES CONSTRUCTION SHALL BE SEQUENCED SUCH THAT GRADING OPERATIONS WILL BEGIN AND END AS QUICKLY AS POSSIBLE. THE SITE SUPERINTENDENT SHALL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION AND SEDIMENT CONTROL MEASURES. MAINTENANCE OF THESE MEASURES THROUGHOUT THE PROJECT ARE CRITICAL TO THE EFFECTIVENESS OF THE PROGRAM. AFTER AREAS ABOVE CONTROLS HAVE BEEN STABILIZED, THE CONTROLS SHALL BE CLEANED UP AND REMOVED. ELECTRIC POWER, TELEPHONE, STORM, SANITARY, WATER & GAS SUPPLY TRENCHES ARE TO BE COMPACTED, SEEDED AND MULCHED WITHIN FIVE (5) DAYS AFTER BACKFILLING. NO MORE THAN 500 FEET ARE TO BE OPEN AT ANY ONE TIME. ALL CUT AND FILL SLOPES ARE TO BE SEEDED AND MULCHED WITHIN FIVE (5) DAYS OF COMPLETION OF GRADING. DRAINAGE SWALES SHALL BE STABIILIZED WITH CHECK DAMS UNTIL VEGETATION HAS BEEN WELL ESTABLISHED, AT WHICH TIME THE CHECK DAMS SHALL BE REMOVED. DEVICES LISTED ABOVE ARE CONSIDERED MINIMUM EROSION ANDSEDIMENT NT CONTROLS. ADDITIONAL CONTROL MEASURES MAY BE NECESSARY DUE TO CONTRACTOR PHASING OR OTHER UNFORESEEN CONDITIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADDITIONAL MEASURES TO THOSE SHOWN, AS NEEDED, IN ORDER TO CONTROL EROSION AND CONTAIN SEDIMENT ON SITE. ALL MEASURES SHALL BE INSTALLED ACCORDING TO THE STANDARDS AND SPECIFICATIONS IN THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. MAINTENANCE ALL CONTROL MEASURES SHALL BE INSPECTED DAILY BY THE SITE SUPERINTENDENT OR HIS REPRESENTATIVE AND WITHIN 24 HOURS AFTER ANY STORM EVENT GREATER THAN 0.5 INCHES OF RAIN PER 24 HOUR PERIOD. ANY DAMAGED STRUCTURAL MEASURES ARE TO BE REPAIRED BY THE END OF THE DAY. SEEDED AREAS SHALL BE CHECKED REGULARLY TO ENSURE THAT A GOOD STAND OF GRASS IS MAINTAINED. ALL AREAS SHALL BE FERTILIZED AND RESEEDED AS NEEDED UNTIL GRASS IS ESTABLISHED. TRAPPED SEDIMENT IS TO BE REMOVED AS REQUIRED TO MAINTAIN 50% TRAP EFFICIENCY AND DISPOSED OF BY SPREADING ON SITE. GRAVEL OUTLETS SHALL BE CHECKED REGULARLY FOR SEDIMENT BUILD-UP. IF THE GRAVEL OUTLET IS CLOGGED BY SEDIMENT, IT SHALL BE REMOVED AND CLEANED OR REPLACED IMMEDIATELY. THE CONTRACTOR IS RESPONSIBLE FOR KEEPING EXISTING PUBLIC ROADS IN A CLEAN, DUST AND MUD FREE, CONDITION AT ALL TIMES. PHASES OF LAND DISTURBANCE ACTIVITIES 1. CLEARING AND GRUBBING FOR SEDIMENT CONTROL DEVICES ONLY. 2. PLACEMENT OF SEDIMENT CONTROL DEVICES. 3. OBTAIN INSPECTOR'S APPROVAL PRIOR TO BEGINNING GRADING OPERATIONS. 4. CLEAR AND GRUB REMAINDER OF SITE. 5. ROUGH GRADE SITE. 7. FINAL GRADING. 8. RESTORATION AND STABILIZATION OF DISTURBED AREAS. 9. REMOVE EROSION AND SEDIMENT CONTROL MEASURES WITH THE APPROVAL OF THE INSPECTOR. SEEDING NOTES: 1. ALL PERMANENT SEEDING SHALL BE IN ACCORDANCE WITH SECTION 3.32 OF THE VESCH. 2. TOPSOIL SHALL BE SPREAD AT A MINIMUM DEPTH OF 4". 3. PULVERIZED AGRICULTURAL GRADE LIMESTONE SHALL BE INCORPORATED INTO SOIL (TOP 4-6 INCHES) AT A RATE OF 90 LBS. PER 1000 S.F. (2 TONS PER ACRE). 4. FERTILIZE WITH 10-10-10 AT A RATE OF 23 LBS. PER 1000 S.F. (1000 LBS. PER ACRE). 5. SEED MIX SHALL CONSIST OF 90% KENTUCKY 31 TALL FESUE AND 10% IMPROVED PERENNIAL RYE GRASS APPLIED AT THE RATE OF 250 LBS. PER ACRE. 6. STRAW MULCH SHALL BE APPLIED TO ALL SEEDED AREAS AT THE RATE OF 3500 LBS. PER ACRE AND ANCHORED WITH CUTBACK, OR EMULSIFIED ASPHALT APPLIED AT A RATE OF 200 GALLONS PER ACRE. ZONING REQUIREMENTS CURRENT ZONING AND USE: B-3 OFFICE AND MANUFACTURING PROPOSED USE: OFFICE AND MANUFACTURING ZONING REQUIREMENTS: PROVIDED: LOT SIZE: 1.0 ACRE MINIMUM 1.0 AC. MINIMUM YARDS: FRONT: 35 FT MINIMUM 58.6 FT. SIDE: 15 FT MINIMUM 15.3 FT. REAR: 15 FT MIINIMUM 36.6 FT. PARKING TABULATIONS: REQUIRED PARKING: OFFICE = 1 SPACE/250 S.F. = 576 S.F./250 = 3 SPACES MANUFACTURING = 3 SPACES PER 4 EMPLOYEES = 8 EMPLOYEES/4 * 3 = 6 SPACES TOTAL REQUIRED PARKING = 9 SPACES PROVIDED PARKING: EXISTING PARKING SPACES = 20 PROPOSED PARKING SPACES = NONE THERE IS NO INCREASE IN OFFICE SPACE OR EMPLOYEES WITH THIS BUILDING ADDITION. HANDICAP SPACES REQUIRED = 1 SPACE HANDICAP SPACES PROVIDED = 1 EXISTING SPACE BUILDING HEIGHT: MAXIMUM ALLOWED = 35' PROPOSED HEIGHT = 12' F.A.R. CALCULATION: F.A.R. ALLOWED = 1.0 LOT AREA = 43,560 S.F. EXISTING BUILDING = 4,000 S.F. EXISTING F.A.R. = 4,000/43,560 = 0.09 PROPOSED BUILDING = 6,000 S.F. PROPOSED F.A.R. = 10,000/43,560 = 0.23 SIGNS: ALL SIGNAGE, BUILDING MOUNTED AND FREESTANDING, SHALL REQUIRE A PERMIT FROM THE COUNTY AND COMPLY WITH THE ZONING ORDINANCE OUTDOOR LIGHTING: ALL LIGHTING SHALL BE SHIELDED TO PREVENT GLARE ON ADJOINERING PROPERTIES, RIGHT-OF-WAYS, AND APPROACHING AIRCRAFT LANDSCAPE CALCULATIONS: REQUIRED LANDSCAPING: PARKING LOT PERIMTER = 1 TREE PER 40 L.F. = 510'/40' = 13 TREES INTERIOR PARKING LOT = 1 TREE PER 10 SPACES = 20 / 10 = 2 TREES TOTAL TREES REQUIRED = 15 EXISTING LANDSCAPING: PARKING LOT PERIMETER = 15 TREES INTERIOR PARKING LOT = 2 TREES TOTAL EXISTING TREES = 17 NO ADDITIONAL TREES REQUIRED BUILDING INSPECTION DEPARTMENT NOTES: 1. BUILDING SHALL COMPLY WITH THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE AND SECTIONS 304.0 USE GROUP B (BUSINESS), 311.0 USE GROUP S (STORAGE) AND 313.0 MIX USES OF THE BOCA NATIONAL BUILDING CODE 1996. 2. ALL REQUIRED EGRESS FROM THE BUILDING SHALL COMPLY WITH A.D.A. 3. USE GROUP B, CONSTRUCTION TYPE 2C. UTILITY CONTACTS Water/Sewer: Frederick County Sanitation Authority P.O. Box 1877 Winchester, VA. 22604 (540) 868-1061 Power: Allegheny Power P.O. Box 1458 Hagerstown, MD 21741 1-800-654-3317 Gas: Shenandoah Gas Co. P.O. Box 2400 Winchester, VA 22604 (540) 869-1111 Phone: Bell -Atlantic P.O. Box 17398 Baltimore, MD 21297 (301) 954-6282 FIRE MARSHAL'S NOTE FIRE LANE MARKINGS AND SIGNAGE: Any "No Parking" signs and yellow painted curb locations will be installed by field inspection at the direction of the Fire Marshall's Office. FIRE FLOW DATA: STATIC PRESSURE _ RESIDUAL PRESSURE _ AVAILABLE FLOW = SOURCE: DATE: HYD# SURVEY N/A DESIGN MSS DRAWN MSS CHECKED MSS U Q w_ o_ UQ (� ® N z f+ ._ (3)�o N V) (O N N 0) zto a� E z aa . •- O 0 L X a- m O -� z fn •- U � o_ V) o' U �n p =+• c In - o > to U) N s� N w w z 0 z w DATE MAY 2004 SCALE HORZ: N/A VERT: N/A SEAL Sp,LTH 0� �(0 LICEN E No. 031162 - �s Qyy� sI®NAL 0 Q 0 0 0 0 W 0 IX B W Z W C7 V �Q B W F- Z 0 2 U Y YU W W � W OW YLLL V OO JOB 2158-0101 0 a w CADD 0 2158nt1 0 0 SHEET 2 OF 3 a 0 r L;tI v L FREDEMCK C0Us ,. STONE CONSTRUCTION ENTRANCE A I EXISTING PAVEMENT FILTER CLOTH 6" MIN. J I BERM (OPTIONAL) A SIDE ELEVATION EXISTING 70' MIN. GROUND (OPTIONAL) 10' MIN. PAW ii=n=u=a=TIRE n_• 2.!'1 R_ ...: ��%�•�I. %�: � ..: � ��I 1 1 1 • FILTER CLOTH REINFORCED CONCRETE 12' MIN. SECTION A -A �►�i�llltll`��10�. SPACE 3" MIN. SILT FENCE INSTALLATION 1. SET THE STAKES 2. EXCAVATE A 4" x 4" TRENCH UPSLOPE ALONG THE LINE OF STAKES. 3. STAPLE FILTER MATERIAL TO STAKES AND EXTEND IT INTO THE TRENCH. 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. JI ILL I I L-%-/vv INSTALLA I IIIIV (PERSPECTIVE VIEW) POINT A SHOULD BE HIGHER THAN POINT B. DRAINAGEWAY INSTALLATION (FRONT ELEVATION) EROSION/SEDIMENT CONTROL LEGEND NO. KEY SYMBOL DESCRIPTION 3.02 CE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE 3.05 SF X X X SILT FENCE 3.07 IP STORM DRAIN INLET PROTECTION 3.09 DD DD TEMPORARY DIVERSION DIKE 3.10 FD FD TEMPORARY FILL DIVERSION 3.12 DIVERSION 3.13 ST TEMPORARY SEDIMENT TRAP 3.18 OP OUTLET PROTECTION 3.20 CHECK DAMS 3.33 SO SO SODDING 3.38 O 0-0-0 TREE PROTECTION LCG LIMITS OF CLEARING & GRADING DRAINAGE DIVIDES CRITICAL SLOPE - CRITICAL SLOPE TO BE SEEDED, MULCHED AND TACKED WITHIN 14 DAYS AFTER START OF GRADING, OR SODDED AND PEGGED WITHIN 14 DAYS AFTER START •• :•: .�i i �i �i �i i 1i i �i i i i i •. VDOT #1 COARSE AGGREGATE FLOW ? 3' CLASS I RIPRAP EM-320-1 RESPONSIBLE LAND DISTURBER NAM E: CERTIFICATION NO.: DATE: THE RESPONSIBLE LAND DISTURBER IS THE PARTY RESPONSIBLE FOR CARRING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. 74 n.,. 1 `�--,-_, PROP. LOCATION FOR J'14 " EITHER THE EX. 3" OAK EX. STM . INLET ' 3A OR NEW 1 1 /2" OAK TREE EX. R -RAP 3" OAK" ,f 3 MA EX EX . DUMPS ER I \ R=325.00 EX. CU B _ AND ENCLOSURE L=36.03' CUT x 10 vd'= 3" MAPLE EX. 25' DRNG . SF ESMT . 3" MAPLE 4V J, O� h 4 EX. TRANS. C E EX. W M TRANCE _V x 1 APPROX . LOCATION 4" OAK 5 4" OAK M - EX. GAS LINE EX. WATE �8 > METEREX. CONC, S/W 1 r ,%� - 1 EX. FIRE". HYDRANT/ :.. � �•. - .+; `_ •• v •r. -,•- r " 3 OAK 80,57.... j EX OVERHEA1 / o m DOOR 1 EXISTING i" NAPLE 9�O ONE STORY METAL BUILDING 1 3 U, e, W/BRICK FRONT 7.8 l Co HEIGHT = 12' i.:1 X FF ELEV. 749.50 1 C " n PROP. 80' - 4" SAN. /, „� 3 MAPLE c '..: EX. GAS METER SEW. LAT . PVC SDR-21 ® 2.08% 1 1 51 50 � 'M 75-A-91E LOT 5 ZONE: B3 SE: OFFICE EX. TREE TO BE EITHER 'REMOVED OR RELOACATED N 340 16' 16■ E 269.87' 477� 15' BRL oC D �` , AQ19 EX. TREE TO REMAIN PROPOSED CONSTRUCTION ENTRANCE W/ WASH RACK 490 120' PROP. 5'X5' CONC. PAD 490 PROP. WAREHOUSE ADDITION GFA = 6,000 S.F. HEIGHT = 12' FF = 749.50 TOP OF FOUNDATION ---- WALL = 752.00 5120 5090 50so 49 0 w J Ln \Icn I m . l rrT1 t 849� 48dI I 36 .6 NO.N. _p— Z mZ vino 00 LAN_ 1 r rl0 CD II I PROP. SAN. C 0 15' BRL 3" MAP x x3" OAK �- 51+ 509 50621 5032 5007 SF F / x 3" BRADFORD-PEAR APPROX. LOCATION EX. SAN. LAT, 20 10 0 20 40 60 GRAPHICAL SCALE: 1 " = 20' STORMWATER MANAGEMENT NOTE: THIS SITE IS CURRENTLY SERVED BY A REGIONAL STORMWATER MANAGEMENT FACILITY LOCATED WITHIN COMMONWEALTH BUSINESS CENTER. RUNOFF FROM THE PROPOSED ADDITION FOR THE 10-YEAR STORM IS (120'X50')(6.8 IN/HR.)(0.90) = 0.84 CFS. THIS RUNOFF WILL FLOW THROUGH THE PROPOSED DITCHLINE AND TO THE EXISTING GRATE INLET LOCATED AT THE SOUTHWESTERN CORNER OF THE SITE. IT WILL THEN ENTER THE EXISTING STORM SEWER SYSTEM THAT CONVEYS FLOW TO THE EXISTING FACILITY. ENVIRONMENTAL FEATURES NOTE: THERE ARE NO KNOWN ENVIRONMENTAL FEATURES, INCLUDING STREAMS, FLOODPLAINS, LAKES AND PONDS, WETLANDS, NATURAL STORMWATER RETENTION AREAS, STEEP SLOPES AND WOODLANDS ON THIS SITE. * 3" BRADFO (SF sanitary sewer main finished 7`�------- -- — -`-------��e .w-- —�— S 340 16' 16' W 331 .78-'� 3'=.BRAi CRD_PEAR w , x TM 75-A-91D LOT 4 ZONE: B3 USE: OFFICE cast iron cleanout cap with brass plug` R having a countersunk square head ��:_ Panella Model PA4SV—CSK (4") ` Panella Model PA6S\(—CSK (6") I I cleanout pipe — wye SDR 21 45' bend square concrete skid pad 20 "x 20"x 12" deep aggregate base ( depth 3" ) 6" stone bedding NOTE Where length of service lateral to exceeds 75' a cleanout assembly shall be furnished at the property line. SEWER CLEANOUT Figure 17 SDR 35 spigot OR 35 spigot by by gasketed SDR 21 gasketed bel! 45' bend bell adapter locator peg �� •i!i' ..�. :��- �-iu LR,f }gip -- ; ')..�A.-%ti i.'�a.il sari-, _-. - :v°r.'.•.. SDR 35 8 x4" gasketed bell w)e 3' minimum SDR 21 gasketed pipe and rittings property 2' SCH en 4 s%g weld cap 36' min. cover GRAVITY SEWER SERVICE LATERAL Figure 15 Ino'l REVISIONS �� SURVEY WHGA DESIGN MSS DRAWN MSS CHECKED MSS I— U w U a U Q N N M + N g c0v,co� v 14- Ln I _N C� I w .. a> o •- LO C E Z Z +' �� O gQU3(7, L X O C >. - -� > t o O - 3 LO p N M 3 fl U N U L O j ' a c m — o a� 0_ C LO c V) ccN U w w z c� w DATE MAY 2004 SCALE HORZ: 1 " = 20' VERT: N/A SEAL N.LTH 0 . AEL S. S1 5 I't oY LICENS 031162 p•I F JZ � o� Z 18" W 0 J a> z g UO W.- CL Q �? W I_- w Q U O U_ Y �0 WW UJ v w with rreen — — cc V LL '..JM m Cc U W D O W d JOB 2158-0101 CADD 2158sp1 SHEET]3 OF 3 RECEIVE" FREDERICKGO Ni ,C PLANNING &DIEVEL