Loading...
HomeMy WebLinkAbout029-88 Quarles Petroleum - Stonewall - BackfileBOCA PLAN REVIEW RECORD Plan Review # 1Q042 Valuation = BASIC/NATIONAL BUILDING CODE Date Ont. _ 29th. 1 9�18 Fee (All Articles except 15, 22 and 24) JURISDICTION Frederick County, Va. (City, County, Township, etc.) BUILDING LOCATION Smithfield Ave (Street address) BUILDING DESCRIPTION pre Pmgi nPPred metal arldi t.i an to existinar Gt.ruct.ure REVIEWED BY J. T. Swiger 'Numerals indicated in parentheses are applicable code sections of 1984 Basic/National Building Code. CORRECTION LIST No. DESCRIPTION Code Section demolished and a new pre-engineered one story metal building is betng replaced ann reT)osltloned to fne remalnlnp exls ing blig. 2. USE GROUP: S-1 Moderath storage (netroleum warehouse) I- RUTTQTNG CONSTRUCTTON TYPE* 2-(' Note: Table 401 directs notice to the fact that exterior bearing and non bearing walls must meet the lire protection require of Table 900-2 nf R(r.A- Chit -side of this requirement, there en s is no "protection" required of the component parts of this addition. Total actuai buildiH-g- area: anprox. 3900 So. Ft. Exterior walls: Loadbearing portion including columns ; 2 ir. protedtion required if away from lot lineanywhere greater than 51to 101 (Note:) The fireresistance rating of exterior walls with a . fire separation alstance of greater tnan j It. Snaii be rated ror exposure to fire from the inside . This includes loadbearing columns.) The plan review accomplished as indicated in the record is limited to those code sections specifically identified herein. Copyright, 1984, Building Officials and Code Administrators International, Inc. Reproduction by any means is prohibited. NOTE: In order that we might develop other programs and provide additional services of benefit to the Code Administration profession, please re -order additional copies of this form from: o� °r`rc ¢ BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL, INC. 2 .g 4051 W. FLOSSMOOR ROAD COUNTRY CLUB HILLS, ILLINOIS 60477 .,�4o,+nai•�'. N01 5 84 Item #4 continued: If the exterior wall is cloer than 5' to the lot line, protection from fire exposure must be made on both sides of the wall. Because of this, and the closeness of the walls to the 51 mark, I recommend that a survey put property nins in place on these two critical property lines. OTHER NOTE: This is not an electrical, mechanical, or plumbing review. It is noted that Richard A. Ruckman, Professional Engineer of Va. using his Virginia engineering stamp approved the foundation details of this building. It is noted that Joe M. Ormand, Jr. Professional Engineer, using his Virginia Engin(erine stamp approved the structural drawings of this building, presented to us by the contractor. This inspections office is conunting fully on the integrity of these drawings for the integrity of this building. Because of the critical nature of obtaining a two hr. fire protection on the interior side of the two walls of this building, we will re- quire a detail on same by a Va. registered engineer, or architect. If during the course of construction, any deletion of Code reouirements are discovered, even if not commented on here, they will be immediately corrected on the plans and incorporated into the construction under- way, all prior to receiving an occupancy permt. it r � ME-T, aIrJIIJG ,J GI 0--rt CGLUM Ki m� qq wALL: Z I.AYFJ2-j 5/8' FIrlt (2ATe0 GYr'SUM f'ANr-L7. p 31_O-TEEL taunt `24-4 QC ATrAGH TO F d• G12T, I� P 4-::)f_ LAYefZ .SCRE\V ATTACH . rZSCE L.AYFr2 L.AMI"ATE Or2. SC2FN QTTACN. JOJIQT'S t7AGGF-QErJ (:S. FIUI'JN OR UIJFItiI��l1Ep. I-Er21MF-r!5Q C,&L.V , riasuMta F20M UL rDEAj, U 4-11 . coLUMN'S: '�> LdYr-RS h" FIRE2oTnrD GY�'oVM Pv.NELS eT COQUO"- 7-QjpLt ILA`fCR O`/FR. FLG►JGE EXTF-Ql02• \\ALL• PLAQ ' E►Jr,), IIJQM-1 L4YCR6 o►J FI,Ow(sE P4G1: 'SEPE(Z- t -rr-O " I5/8" 6-1EEL 6-fU05 6. 6C2E\V e-rTAC- . METpL �EAp� Otil COfLNC;Z'S, JOIIJTg P:lQlt)WF-CDP- UL rxs X 52d- • aATIIJ G er-PU F-S -TO TAI-EaCr-- f>QE- FeP�r2lceTF1J METALF>LrJG. COLUM►Jt�. 2 H2 PRGilnGTIGr.I FG2 ►Jo►J>=�cTE21G2 \VL�I_l� ►��dRII.1G COLb (24-f ErJ FCG2 EXP0±>U21F- TO FIRE F20t/1 I►,ITE,r2102 .71rDf—. ">,dl bU I LrJI UC-. ' AI DrJ IT I Oki QUA QLE.5• Pff-7WLE.UM • I IJ C - 825- 6MI-rHFIr 1 0-,6VE \✓INCHE67E.2• VA- 15 FEPJ 8q CONSTRUCTION MANAGEMENT, INC. 150 McGHEE ROAD WINCHESTER, VA 22601 -? - i./,- - ;? Y