HomeMy WebLinkAbout024-82 Medical Offices - Richard L. Vaitsas - Backfileoz�"a'i Ot January 26, 1983 Dr. Richard L. Vaitsas 1328 Stanley Circle Winchester, Virginia 22601 Dear Dr. Vaitsas: This letter is to confirm the Frederick County Planning Commission's action at their meeting of January 19, 1983: Approval of Site Plan #024-82 of Richard L. Vaitsas, D.C. for medical offices with required off-street parking on Garber Road, off Route 522 South, in the Shawnee Magisterial District. If you have any questions, please do not hesitate to contact this office. Sincerely, John T. P. Horne Director JTPH/rsa Enc: Approved Site Plan SITE PLAN # 024-82 Richard L. Vaitsas Zoned B-2 (Business, General) LOCATION: Garber Road, off Route 522 South MAGISTERIAL DISTRICT: Shawnee Magisterial District ADJACENT LAND USE AND ZONING: Commercial and Residential Land Use and Commercial Zoning PROPOSED USE AND IMPROVEMENTS: Medical offices with required off-street parking REVIEW EVALUATIONS: Virginia Dept. of Highways and Transportation - No objection; off -site drainage requirements will be noted at time of permit application. Department of Inspections - Fire hydrant should be available within 500 feet of the proposed building. Handicapped access to building will be necessary when plans submitted. City of Winchester - City water and sewer is available for the proposed construction by Richard L. Vaitsas, D.C. on a lot located on Garber Road in Frederick County, Virginia. The proposed water and sewer connection is in accordance with City policy. Planning and Zoning - No objection. STAFF RECOMMENDATIONS: Approval. (91itV of Xlinr4r ofer, Pirginm December 27, 1982 TO WHOM IT MAY CONCERN: ROU55 CITY HALL 22601 City water and sewer is available for the proposed construction by Richard L. Vaitsas, D.C. on a lot located on Garber Road in Frederick County, Virginia. The proposed water and sewer connection is in accordance with City policy. / James W. Givens, P.E. Public Utilities Director "T4'e ckpple &Pital„ .6- x���xtx�: C�arxxr#g 0 Z. Pqartment af Planuing nub P.efrQ vy:rae t DIRECTOR P. O. BOX 601 JOHN T. P. HORNE 9 COURT SQUARE DEPUTY DIRECTOR M E M O R A N D U M WINCHESTER, VIRGINIA 22601 STEPHEN M. GYURISIN TO: Department of Inspections , ATTN Mr. John Dennison Zoning _ , ATTN Mr. Stephen Gyurisin Planning , ATTN Mr. John T. P. Horne ATTN Highway Department , ATTN Mr. W. H. Bushman FROM: John T. P. Horne, Director Date December 30, 1982 SUBJECT: Review comments on Conditional Use Permit Subdivision Rezoning X Site Plan We are reviewing the enclosed request by Richard L. Vaitsas or their representative Will you please review the attached and return your comments to me as soon as possible. ---------------------------------------------------------------------- This pace /should be used for review comments: n SignatureDate 703/662-4532 L'l M, 5 ' 5' 15' SCALE E ,U E- _6 69 �� � - 9� 2 •� � eke ��' n N' so I'vr > /, �iGy�Jco Ay tv L r V FINAL PI -AT �\ GAR BER'S SUBDIVISION GARBER TRUST OWNER 3.535 ACRES LOCATED 0.7 MILE SOUTH OF WINCHESTERAND SITUATE IN SHAWNEE DISTRICT, FREDERICK COUNTY, VA. R;CHAID U, GOODE CFPTI, Ic-r, _ 5466� 1,J�r 1' O -1,e], I /I P, I IE EXISTING GR DE 2'S5 8"BASE 20 JO 40 SO 60 70 80 90 100 108.5 SECTION THROUGH ENTRANCE SCALE 1"- 10' HORIz. 1*- S' VERT. 10 LOCATION MAP SCALE 1' - 2000' EXISTING SANITARY SEWER MAIN IN 10 0' EASEMENT OLD 522 0) II II II II II II II II II II II C) zA '� V 10 Sao, ITJ 1025' 715 QQ EXISTING GRADE-- - - 710 __ \\ 710 \2' SS 6" BASE T O 705 EXISTING WATER MAIN— SECTION THROUGH PARKING LOT SCALE I" • 10' HORIZ. 1' • 5' VERT. EXISTING / 2U- 15" C.M. PIPE AT 5.0 % INV, IN 702.4 TOP H.W. 704.4 p EXISTING 7/5 DRIVEWAY �_-- E.P. E.P4. 705-/' -�� i 704 1 / 1 TEMPORARY STRAW BALES rV SEDIMENT I BARRIERS 1 / / 1 706 0 N i / 707 , - GO'- 42"X 29 ••C M. CULVERT PIPE AS AP ROVED BY V D. 0 Io CONC. TROUGH DRAIN- TEMPORARY STRAW BALES RIP -RAP DISCHARGE END SEDIMENT BARRIER AT CULVERT 7?6 7p7 7d8 70g WALK O O N •j. _ r 0' T\5 T\3 _--------� N B8-24-22' W 200.00716 -- —' NOTES' EROSION AND SEDIMENT _CONTROL I. DRAINAGE DITCHES AND SEDIMENT BARRIERS MUST BE INSTALLED AT BEGINNING OF LAND DISTURBING ACTIVITY. 2. ALL DISTURBED AREAS TO BE REVEGETATED AS SOON AS POSSIBLE AFTER GRADING. 3. SEDIMENT BARRIERS AND ACCUMULATED SILT TO BE REMOVED AFTER DISTURBED AREA IS REVEGETATED OR STABILIZED. 4. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. NOTES- GENERAL I. ALL FILL TO BE COMPACTED TO 95%. 2. ALL CURB AND GUTTER TO BE V.D.H. STD. CG-6. 3. ALL PAVING TO BE 6"BASE 4 2"S-5. 716 CD . fn O (N 714 0 M EXISTING M.H. TOP= 717. 94' INV, IN - 709.79' I N V. OUT - 709.70' LEGEND 71s FINAL SITE PLAN — EXISTING CONTOUR APPROV0 �<� TIS FINISH CONTOUR � Dr+l L, S:1 SITE & GRADING PLAN OFFICE BUILDING FOR o RICHARD L. VAITSAS, D.C. WINCHESTER, VIRGINIA HINMAN CONSTRUCTION CO. Qp SITE PLAN PREPARED BY FOUNDATION ENGINEERING OF VIRGINIA, INC. WINCHESTER, VIRGINIA Scale I"= 10 Date 12-2E Drawn by DF Checked by L( Revised Sheet No. 1 of I she,