HomeMy WebLinkAbout020-82 T.G. Adams - Back Creek Dist. - Backfile1v 0 Ptyax#znent of jEanntng nnb PQfreloy ent DIRECTOR JOHN T. P. HORNE DEPUTY DIRECTOR STEPHEN M. GYURISIN October 25, 1982 Mr. T. G. Adams Route 3, Box 247 Winchester, Virginia 22601 Dear Mr. Adams: P. O. Box 601 9 COURT SQUARE WINCHESTER, VIRGINIA 22601 This letter is to confirm the Frederick County Planning Commission's action at their meeting of October 20, 1982. Approval of Site Plan #020-82 of T. G. Adams, zoned B-2 (Business, General), for the construction of 18 additional motel units and required parking facilities in the Back Creek Magisterial District. If you have any further questions, please do not hesitate to contact this office. Sincerely, John T. P. Hirector JTPH/rsa Horne 703/662-4532 SITE PLAN #020-82 T. G. Adams Zoned B-2 (Business -General) LOCATION: Rt. 11 South at the northwest corner of the Rt. 11 - Rt. 37 Interchange. MAGISTERIAL DISTRICT: Back Creek Magisterial District ADJACENT LAND USE AND ZONING: Residential and commercial land use and residential, commercial, and industrial zoning. PROPOSED USE AND IMPROVEMENTS: Construction of 18 additional motel units and required parking facilities. REVIEW EVALUATIONS: Virginia Dept. of Highways and Transportation - Site plan appears satisfactory. A commercial entrance was applied for and entrance was constructed to our minimum requirements several years ago. Department of Inspections - No objection. Health Department - No objection. Consultation with Division of Water Programs indicates around 94% BOD loading on system. Any significant sewage increase in future will require upgrading of present system. Planning & Development - No objection. STAFF RECOMMENDATIONS: Approval. SITE PLAN REQUIREMENTS - T. G. ADAMS ECHO VILLAGE MOTEL 1. Widen and pave southeast entrance to minimum 22'. May be done through affidavit after final C.O.C. issued. J�reberirk Tonn#p RF '�f,+�En Department of jjlttnning anb p6rlopmen# DIRECTOR JOHN T. P. HORNE DEPUTY DIRECTOR STEPHEN M. GYURISIN M E M 0 R A N D U TO: " O. Box 601 nn -` '�OURT SQUARE INCHeS _'R. VIRGINIA 22601 4 uu��/ 1 rG� riC 4 Department of Inspections , ATTN Mr. ohn Dennison - Zoning , ATTN Mr. Stephen Gyurisin Planning , ATTN Mr. John T. P. Horne Health Department , ATTN Mr. Herbert Sluder Highway Department , ATTN Mr. W. H. Bushman ✓ FROM: John T. P. Horne, Director Date October 5, 1982 SUBJECT: Review comments on Conditional Use Permit Subdivision Rezoning X Site Plan We are reviewing the enclosed request by T. G. Adams Land or their representative T. G. Adams (869-2112) Will you please review the attached and return your comments to me by October 14, 19b2. ---------------------------------------------------------------------- This space should be used for review comments: Site plan appears satisfactory. A commercial entrance was applied for and entrance was constructed to our minimum requirements several years ago. 1 Signature _*�,�,. Date 703/ 662-4532 �re�Eri�l� satin#� � 5 PEpartnient of 1hauning aub peftBlapmen# DIRECTOR P. O• BOX 601 JOHN T. P. HORNE 9 COURT SQUARE DEPUTY DIRECTOR WINCHESTER. VIRGINIA 22601 STEPHEN M. GYURISIN M E M O R A N D U M "sue Department of Inspections , ATTN Mr. John Dennison/ Zoning , ATTN Mr. Stephen Gyurisin Plannin , ATTN Mr. John T. P. Horne Health Department , ATTN Mr. Herbert Sluder Highway Department , ATTN Mr. W. H. Bushman FROM: John T. P. Horne, Director Date October 5, 1982 SUBJECT: Review comments on Conditional Use Permit Subdivision Rezoning X Site Plan We are reviewing the enclosed request by T. G. Adams Land or their representative T. G. Adams (869-2112) Will you please review the attached and return your comments to me by October 14, 1962. ---------------------------------------------------------------------- This,space should be used for review comments: Signature Date 703/662-4532 �reberirk (gonn#V RECE� d 0 G r 1 4 W2 Pepor#ntrn# of 1hanning anb P6elopmen# onv (o DIRECTOR P. 0. BOX 601 JOHN T. P. HORNS 9 COURT SQUARE DEPuTY DIRECTOR WINCHESTER, VIRGINIA 22601 STEPHEN M. GYURISIN M E M O R A N D U M TO: Department of Inspections , ATTN Mr. John Dennison Zoning , ATTN Mr. Stephen Gyurisin Planning , ATTN Mr. John T. P. Horne Health Department ATTN Mr. Herbert Sluder v� Highway Department , ATTN Mr. W. H. Bushman FROM: John T. P. Horne, Director. Date October 5, 1982 SUBJECT: Review comments on Conditional Use Permit Subdivision Rezoning X Site Plan We are reviewing the enclosed request by T. G. Adams Land or their representative T. G. Adams (869-2112) Will you please review the attached and return your comments to me by October 14, 1982. Signature�,�p ��+_ Date IQ- 13 —$Z 703/662-4532 400,7m, /- e. 1. 1 ........ .. / T"', I'll. I - ..-I.. ...T- HG Jaay 40 0 4D 17/01V /Vo/&'� 4s,,o ,�/o C4,16 lob ............. .. lj,,e 39 ' ';. �� A/00, 64/ - 61;'16 � o 4 t1 N v.POiCJEO 04VfNEA/7 l -- ---------- ----�Exis rr.vc Ltxo6------- a O" BASE oR/ME f S 4L SEC: T/On/ r"RU. PROPOSED PAVEMENT SEC.A - A EPOSION AND SEOWCAIT DRA/NA6E O/TC//ES 4N0 SEO/MENT BARR/ERS MUST BE /NSTACCEO AT 8E6/N,V/N6. OFCANO 49/f7R419/N6 ACT/V/TY. Z. ACC O/STRUBEO AREAS TO BE REVc6ErATEO AS SOON AS POSS/BCE AFTER CRAO/N6. J. 5E0/MENT SARR/ERS ANO ACCC/MUCATED S/CT rod,, R6.MOVEO AFTER O/ST,PC/SEO AREA /S REVE6ETATEO OR STAB/C/Z£D. 4. ACC WO.Pk.SL/ACC SE PfFaRMEO /A/ ACCORDANCE W/TN T/JE V/A16/.V/A EROS/ON AND SEDIMENT fONTROC NAND8WK. N30•04•`%E _ 3g0. 00, I 1 I 6X/r�N� — _ I o4`E�Eq/7 \ I� i Ofj�e I 0 ... ... .... .. ........... 14V Ile Iln -------- -- Qa it . ....................................... zs Ira .. . .................. . ............................ ----------------- ------------- ---------------------------------- -714 ----------------- i Off�e 1 � O o �G. � atih \ A., �0 1fov/e t(�-J v / a pPd. . >I tri - ✓unc --_-- o Te/ePhane Pole Light fcv? ..... p11i on �•: "OPo/ •Wobr �W `AP . C/eonoul .._... _...... 75/ • 4sio ooX. /M.' r.� • �a p a43 CC.?T-f:CAT^. No. > fr?u sw1 *-I 729 ii. yh673 0.+.,Y.tt-1 uus2 s a LEGEND Ex/strop Pawmenl N' Proposed Pavement Proposed sidowam —752— F/n/sh Grad* 752 -- - - Erishnp Grade x 752.5 F/n/sh Spot Geode AT EA 6 jrpy Topographic: a/ Survey T. G. Adams. Land Bock Creek D/strict — Frederick County Viryiniv Scale /" -v 20' — ✓away 27, /977 P/epared By Greenway Engineering B Surveying Company /na P 0. Box 666 Winrhoelnr I/iminin •+ 0 JAMES 8 KF NE E v M U ( 1-MM'S S, ON#% To: From: Subject: RECEIVED p C t 1 8 1982 COMMONWEALTH ()f VIKCJINIA LEXIN(-,TON REGIONAL OFFICI nel)artment of Health , 129 SOUTH RANDOLPH STREET POST OFFICE BOX 91S Division of Water Programs L F XING7ON VIRWNI4 24450 PHONE 703.'46:F 717E MFMORAND04 H. Y. Bodkin, Regional Sanitarian Datei October 14, 1982 Northwest Regional Office -VMC Ronald E. Conner, P.E. - Regional Director - Lexingtor Regional Office Frederick County - Sewerage • Geieral (Echo Village Motel) This is in reference to Mr. Herb Sluder's recent discussions with Mr. Torn Eberly regarding the addition of 18 units to the Fcho Yilleqe Motel and the capatility of the existing lagoon to handle the increased flow. Rased upon Mr. Eberly's evaluation, the existing lagoon should be capable of handling the additional loading, however, any further system expansion %veld require significant upgrading and possible expansion of the existing treatment facility. Calculations used in determining systm capability: Flow Calculations Design Flow of Lagoon: Original Design - (370 persons)(100 GPD/person) - 37,000 GPD Present Criteria - (200 person/Ac)(lk Ac)(100 GPD/person) - 30,000 6PD Use 30,000 GPD for evaluation purposes. metered usage (water) - 18.300 GPD Est. additional flow - 18 x 130 GPD - 2340 GPD Total est. system usage - 20,640 6PD Should be hydraulically okay Organic Loading Lagoon Loading ' Max. Lagoon Loading Original Design - 60 lbs/Ac 60 lbs/Ac x 1's Ac - 90 lbs Present Criteria - 40 lbs/Ac 40 lbs/Ac x 11% Ac • 60 lbs Use 60 lbs (max) loading for evaluation. Page 2 October 14. 1482 Population Equivalent Motel - 7440 GPD x (person/65 GPD) - 115 persons Other - 13.200 GPD x (person/100 GPD) - 132 persons Organic Loading Motel = 1.15 persons x 0.26 lbs/person = 29.S lbs Other = 132 persons x 0.2 lbs/person 26.4 lbs Total organic loading 71.3 r.! Percentage of Lagoon Loading - 56.3/60 - 94`" Should be organically okay. Should you have any questions, please do not hesitate to contact this officc. NTE/c cc: State Water Control Board - Bridgewater Mr. H. L. Sluder - Lord Fairfax Health District