HomeMy WebLinkAbout002-90 Eastern Frederick Elementary School - Shawnee District - BackfileX -V r SITE PLAN CHECKLIST The application is not complete if the following are not resent: 1. Two sets of comment sheets from the following agencies along with any marked copies of the plan; f.� 2-7 VDOT-OK" N City of Winchester Co. San. Auth. Co. Hlth. Dept. Inspections Dept. Parks & Rec. Fire Marshall -OK- ►�l/� Airport Authority 2. 2 copies of the Site Plan application 3. 5 copies of the plan on a single sheet 4. 1 reproducible copy of the plan (if required) 5. a 35mm. slide of the plan (if required) * One copy of the application and comment sheets, two copies of the plan and the marked plans from the review agencies should be enclosed in a package which will be forwarded to the County Engineer. TRACKING DATE Application Received 2 21 go Site Plan forwarded to Consulting Engineer 3 r i() Review/Invoice received from Engineer Fee Paid (amount $ 810.0 % ) Site Plan heard by Planning Commission (if required) Final Site Plan submitted with review agency, Planning Commission, and staff comments addressed.. / r J 1�Ji z� o r� {�C1 n �l 1��i nnX�z� ✓ 1",1> ��� 5 Z I `7 .V W RECEIPT N'2 0?2777 AMOUNT PAID BALANCE DUE PAID BY CASH L CHECK OTHER FREDE,MK COUNTY DEPT. OF PLANNING AND DEVELOPMENT P.O. BOX 601 • 9 COURT SQUARE VNC HLt TER, VIRGfN1A 22601 • (703) 665-5651 I DATE 7 RECEIVED FROM - -- ADDRESS THE SUM OF FOR BY _. DOLLARS S i DAY -TIMERS RE -ORDER No. 3221 — Printed in USA k-"D- . se-0 00 2 -90 COUNTY of FREDERICK IDepartment of Planning and Development 703/665-5651 FAX 703 / 667-0370 December 11, 1990 Frederick County School Board Attn: Mr. R. Thomas Malcolm 1415 Amherst Street Winchester, Virginia 22601 Dear Mr. Malcolm: Our 1990 records indicate that Site Plan #002-90 for Eastern Frederick Elementary School was approved on May 3, 1990. This approved site plan is located on Route 522 South in the Shawnee Magisterial District. Please keep this approval letter in your file. If I may answer any questions regarding this letter, please do not hesitate to contact me. Sincerely, &XI a . -a-t- Evan A. Wy tt Planner II EAW/slk 9 Court Square - P.O. Box 601 - Winchester, Virginia - 22601 UH I'' A '�P-e- toz-9Z Cfi'UNTY OF FREDER I Ck:: , VIRGINII, * FIRE MARSHAL'S OFFICE `AND DEVELOPMENT COMMENTS Control No. 1209911099 Date Received 020492 Date Reviewed 021992 Applicant i`d;:ame S. S. O. E. Address 1001 Madison Avenue Toledo, Ohio 43624 Project Name Hershey Pasta Phone No. 419-255-38301 Type of Application Site Plan (Rev.) Current Zoning M-1 1st Due Fire Co. 13 1st Due Rescue Co. 13 Election District Stonewall RECOMMENDATIONS Automatic Sprinkler System X Residential Sprinkler System Automatic Fire Alarm System X Other Emergency Vehicle Actress; Adequate X Inadequate Not Identified Fire Lanes Required; Yes X No Comments: As stated on review dated 12/09/91. Roadway/Aisleway Widths; Adequate X Inadequate Special Hazards Noted; Yes Comments: Not Identified No X UH Hydrant Locations; Adequate X Inadequate Not Identified Siamese Connection Location; Approved x Not Approved Not Identified Additional Comments; All requested corrections to site plan have been made. Thank: you. Site plane approved. Review Time .S hr. PLANS APPROVED FIRE MARSHAL, FRED RICK COUNTY Douglas A. k::iracofe Fire Marshal Application for a Site Plan Complete the following application: Development's Name: Location of Property: (by street names) DATE 12/11/89 Eastern Frederick I Elementary School Route 522 South Application # O& Z- 01 Property Owner' s Name: Frederick County School Board Address: 1415 Amherst Street Winchester, VA 22601 Telephone: (703)662-3888 Applicant/Agent: Mills, Oliver & Webb, Inc. Address: 200 Country Club Drive Plaza I, Bldg. E Blacksburg, VA 24060 Telephone: (703)552-2151 Designer/Design Co.: Address: Mills, Oliver & Webb, Inc. 200 Country Club Drive Plaza I, Bldg. E Blacksburg, VA 24060 Telephone: (703) 552-2151 Contact: Philip Pappas Total Area of Property: 16 Acres H Tax Map Number: 76 nnA Parcel Number: 90 Property Zoning and Present Use: Agricultural Adjoining Property Zoning and Present Use: Agricultural Proposed Uses: Frederick County Public School Magisterial District: Shawnee 5 RECEIPT 022601 AMOUNT DUE $ 3.)( AMOUNT PAID $ U.0 BALANCE DUE $ PAID BY CASH n -CNECK ❑ OTHER 'qwF'l%%DEiiICK COUNTY DEFT. Of P>_AP;N:NG AND DEVELOPMENT P 0. BOX 601 • 9 COURT SQUARE W:NCHESTER, VIROINIA 22601 DATE RECEIVED FROM L ADDRESS v / THE SUM OF .(-1A p DOLLARS $ FORBy USA e.e- ) T /1 0 0 r■ 2.5,od f l.00 LAND DISTURBING PERMIT ISSUED TO: who has met all requirements of the Frederick County Erosion and Sedimentation Control Ordinance as certified by the Frederick County Department of Planning and Development. AGREEMENT This agreement, made this Nh Z- day of r1 gy,-0 g , 19qb, by and between party(s) of the first part, and the -.-County of Frederick, Virginia, party of the second part. Whereas, in consideration of the approval by the party of the second part of this Virginia land disturbance plan and permit for LRN F_L and the party of the second part requiring the following work to be completed during the land disturbance construction and before final occupancy, the party(s) of the first part or his heirs/ assigns agree to do the following work: 1. Provide for the adequate control of erosion and sedimentation by temporary and permanent control practices and measures which will be implemented during all phases of clearing, grading and construction and to provide for conformity with the Virginia Erosion and Sediment Control Law, Title 21, Chapter 1, Article 6.1 of the Code of Virginia and local code laws. 2. To provide Erosion and Sediment Control as per the Erosion and Sedimentation Control Plan. 0 - 2 - 9 The party(s) of the first part does further agree that an agent of Frederick County shall be permitted entry to the site of the land disturbing activity to inspect the control measures shown in the approved plan. In testimony whereof, the party of the first part has hereunto caused its corporate names and seals to be hereunto affixed, for and in. its behalf, by rI Q and caused this agreement to be acknowledged and delivered for and in its behalf. Corporation BY:�. In testimony whereof, the party of the second part has hereunto caused its body corporate names and seal to be hereunto affixed, for and in its behalf by F.yAt) A,\W/. yg��— County of Frederick, Virginia BY: _ Frederick Cou y Department of Plan ing & D'eLvelopment NOTE: Issuance of this permit does not constitute approval of a site plan. This permit is for land disturbance only. t a Natar} amd County aforesaid, do her,--*,-)Y, --ertify that appQared before me in -my sa id Countv, �T! �:, -ay.-der�ck County Depc-rtment of P-,anningz.i,-� Dev414�. Puirn% ar! signed to the foregoing agreement. date,* Ii5afc--a me and acknowledged the same ,Uy han.1 this day of C,,_ '. Notary Puidlic mt! 3.aian expires on - T--- �� COMMONWEALTH of V1RQ1N1A DEPARTMENT OF TRANSPORTATION P. O. BOX 278 EDINBURG, 22824 RAY D. PETHTEL WILLIAM H. BUSHMAN COMMISSIONER RESIDENT ENGINEER (703) 984-4133 July 5, 1990 Ms. Patricia M. Torbert C/O Hills, Oliver & Webb, Inc. 200 Country Club Drive Plaza I, Building E Blacksburg, Virginia 24060 Dear Pat: Ref: Armel Elementary School Route 522 South Frederick County This is to advise of an on site review of the above referenced project by a representative of our District Traffic Engineering Section. We concur with your proposal to install guardrail at both the Ketterman and Staton driveways because of the steepness of the adjoining slope. Standard GR-2 guardrail should be installed with the exact lengths and locations to be determined once the fine grading is completed. Please be advised this Department will not be responsible for future maintenance of the guardrail. Should you have any questions concerning this matter of if I can be of further assistance, do not hesitate to call. RBC /rf xc: Mr. R. L. Moore Mr. J. B. Diamond ,V1r. . F . E . Wyme r Mr. Tom Malcolm Mr. R. W. Watkins Sincerely, W. H. Bushman Resident Engineer By: Robert B. Childress Hwy. Permits & Subd. Spec. Senior TRANSPORTATION FOR THE _11STCENTURY f 4': yyF�tiRTri~y COMMONWEALTH of VTRCjINIA DEPARTMENT OF TRANSPORTATION P. O. BOX 278 RAY D. PETHTEL EDINBURG, 22824 WILLIAM H. BUSHMAN COMMISSIONER ( 703 ) 984-4133 RESIDENT ENGINEER April 23, 1990 Mr. Thomas Dolan, Contract Admin. Ref: Eastern Frederick Elementary School Perry Engineering Company, Inc. Route 522 South Route 6, Box 152-B Frederick County Winchester, VA 22601 Dear Tom: Enclosed you will find the approved Land Use Permit Assemblies #855-01015 and #855-01023 to cover work on the States right-of-way at the above referenced project. Upon receipt please contact this office so an on site meeting may be scheduled with your field personnel to review permit and traffic control requirements. I will be looking forward to hearing from you soon. RBC/ rf Enclosures xc: Mr. R. L. Moore Mr. J. B. Diamond Mr. J. C. Heatwole Mr. F. E. Wymer Mr. Tom Malcolm Mr. John Whitacre Mr. R. W. Watkins Sincerely, W. H. Bushman Resident Engineer By: Robert B. Childress Hwy. Permits & Subd. Spec. Senior VI AP i 2 41990 TRANSPORTATION FOR THE 21 ST CENTURY 4 RAY D. PETHTEL COMMISSIONER COMMONWEALTH of VIRCjINIA DEPARTMENT OF TRANSPORTATION P. O. BOX 278 EDINBURG, 22824 Ms. Patricia M. Torbert C/O Mills, Oliver & Webb, Inc. 200 Country Club Drive Plaza 1, Building E Blacksburg, VA 24060 Dear Ms. Torbert: (703) 984-4133 February 27, 1990 WILLIAM H. BUSHMAN RESIDENT ENGINEER C-ilh'x/ Ref: Eastern Frederick Elementary School Route 522 South Frederick County This is to acknowledge receipt of your revised plans dated February 20, 1990 to the above referenced location. The plans appear satisfactory and are approved. Please advise the School Board accordingly. I offer the following comments: A preconstruction conference be held by the engineer and/or School Board with the attendance of the contractor, various County agencies and VDOT shall be conducted prior to initiation of work. Materials used and method of construction shall apply to current observed VDOT Road and Bridge Specifications applicable during construction of this development. Our review and comments are general in nature. Should conditions in the field exist such that additional measures are warranted, such measures shall be completed to the satisfaction of the Department prior to inclusion into the Secondary Road System. Attached is a copy of the minimum requirements and data for subdivision streets prior to acceptance into the Secondary System. This is the responsibility of the developer. All drainage is to be carried within the right-cf-way in ditch lines or gutters along the street to a pipe or drainage easement. The contractor shall notify VDOT when work is to begin or cease for any undetermined length of time. VDOT will also require 48 hours notice for inspections. Any entrances constructed from the referenced street(s) shall meet VDOT minimum standards. This is the developer's responsibility Any signs to be installed will be in accordance with attachments. TRANSPORTATION FOR THE 21ST CENTURY W Ms. Patricia M. Torbert February 27, 1990 - Page Two - Necessary land use permits shall be obtained before any work is performed on the State's right-of-way. As we have previously advised an agreement will be required from the Frederick County Sanitation Authority which absolves VDOT of any relocation or modification costs of the proposed 8" sanitary sewer crossing of Route 522 if such were warranted as a result of the planned improvements to this section of roadway. This will be required prior to issuance of a land use permit to cover said crossing. Because of the extensive amount of work to be performed on the right-of-way and in accordance with the Department's Land Use Manual, it will be necessary for the County to pay the full salary and expenses of a State assigned Inspector. The cost will be billed monthly on an account receivable basis. I suggest any utilities and/or storm sewer placed within the proposed right-of-way be backfilled completely with C.R. Type 21-A Stone. This will greatly reduce the possibility of any pavement settlement. Should you need additional information, do not hesitate to call. Sincerely, W. H. Bushman Resident Engineer q, � t z I L�3, a/,)., C � By: Robert B. Childress Hwy. Permits & Subd. Spec. Sr. RBC / rf Attachments xc: Mr. R. L. Moore Mr. J. B. Diamond Mr. J. C. Heatwole (w/ 1 set of plans) Mr. F. E. Wymer (w/ 1 set of plans) Mr. R . W . Watkins Mr. Tom Malcolm Mr. Wellington Jones Mr. Donnie Bowers • • FE-B 2, 01990 COMMONWEALTH of VIRQfNIA DEPARTMENT OF TRANSPORTATION P. O. BOX 278 RAY D. PETHTEL EDINBURG, 22824 WILLIAM H. BUSHMAN COMMISSIONER`�j'� RESIDENT ENGINEER (703) 984-4133 --w'►/'1 .' February 15, 1990 Mr. Thomas M. Dolan, Contr. Admin. Ref: Temporary Construction Entrance Perry Engineering Company, Inc. Eastern Fred. Elem. School Route 6, Box 152-B Route 522 South Winchester, VA 22601 Approx. 0.28 Mi. N. Rte. 642 W. (East Side) Frederick County Dear Tom: This is to acknowledge receipt of your letter dated February 13, 1990 concerning your request to construction a temporary construction entrance at the above referenced location. As requested you are given permission to construct the temporary entrance. This letter is to serve as your permit to do so. The following are to be a part of this permit agreement: 1. While working on the State's right-of-way it will be necessary to use "Men Working" signs which must be erected prior to starting work and removed daily. 2. Traffic control will be in strict accordance with the attached. 3. Positive drainage is to be maintained within the right-of-way at all times. 4. Work on the right-of-way will be confined to the temporary entrance location only. 5. A minimum 8" of coarse aggregate by 40' in width will be required to be placed from the edge of the roadway and extended back onto private property far enough to prevent carrying of mud onto the roadway. 6. It should be understood any disturbed turf on the State's right-of-way will be topsoiled and reseeded. 7. Any damages to the pavement structure of Route 522 adjacent to this entrance will be corrected by your firm to the satisfaction of the Virginia Department of Transportation. 8. This Department will not be held liable for suit should such result from this operation. 9. This permit is being issued for 180 days. TRANSPORTATION FOR THE 21 ST CENTURY t • • Mr. Thomas M. Dolan February 15, 1990 Page #2 If these requirements are not followed this temporary construction entrance permit will be revoked. Should you have any questions concerning the above, please do not hesitate to call. RBC / rf Attachments xc: Mr. R. L. Moore Mr. D. E. Lee Mr. F. E. Wymer Mr. R. W. Watkins Mr. Tom Malcolm Sincerely, W. H. Bushman Resident Engineer By: Robert B. Childress Hwy. Permits & Subd. Spec. Senior COMMONWEALTH of VIRQ1 DEPARTMENT OF TRANSPORTATION P. 0. BOX 278 RAY D. PETHTEL EDINBURG, 22824 COMMISSIONER (703) 984-4133 February 13, 1990 Mr. Robert E. Dick C/O Mills, Oliver & Webb, Inc. 200 Country Club Drive Plaza 1, Building E Blacksburg, VA 24060 Dear Mr. Dick: • :J WILLIAM H. BUSHMAN RESIDENT ENGINEER Ref: Eastern Frederick Elementary School Route 522 South Frederick County As requested we have reviewed the above referenced development's site plans dated October 26, 1989. Our recommendations may be found on the attached plans marked in red and as follows: 1.) In order to accommodate the entry drive its proposed right-of-way is to be adjusted as noted. 2.) The existing embankment to the north of the entrance is to be sloped to improve sight distance. 3.) A Standard VDOT Stop Sign will be required at the intersection of the entry drive to Route 522. 4.) The cul-de-sac pavement radius is to be increased to 45' as noted. 5.) The proposed 8" sanitary sewer crossing of Route 522 is to be encased from the eastern right-of-way line to Manhole "G" on the western side of the roadway as noted. An agreement will be required from Frederick County Sanitation Authority which absolves VDOT of any relocation or modification costs of the crossing if such were warranted as a result of planned improvements to this section of Route 522. Please revise and resubmit seven (7) copies of the site plan for final approval. Should any changes be deemed necessary, please design them to meet or exceed the above recommendations. We apologize for any delays we may have caused as a result of our review time. However, as I am sure you.are aware, the plans had to be forwarded to our Central Office in Richmond for any comments they may have had relating to the proposed improvements to this section of Route 522. TRANSPORTATION FOR THE 21 ST CENTURY 0 r� Mr" Robert E. Dick Fe�ruary 13, 1990 ,Page # 2 Should you have any questions or if I can be of further assistance do not hesitate to call. Sincerely, W. H. Bushman Resident Engineer OL By: Robert B. Childress Hwy. Permits & Subd. Spec. Senior RBC/rf Attachments xc: Mr. R. L. Moore Mr. J. B. Diamond Mr. J. C. Heatwole Mr. F. E. Wymer Mr. R. W. Watkins, Fred. Co. Planning Mr. Tom Malcolm, Fred. Co. Schools Mr. Wellington Jones, F.C.S.A. Mr. Donnie Bowers, Perry Engr. �2 February 27 , 1990 Evan Wyatt, Planner Frederick County Dept. of Planning & Development 9 Court Square, P.O. Box 601 ENGINEERS Winchester, Va. 22601 ARCHITECTS SCIENTISTS Re: E. Frederick Elementary School L.D. #005-90 17555.059 Dear Evan, I have reviewed the Erosion and Sediment Control Plan for the above referenced project. I offer the following comments and recommendations. GENERAL 1. The submitted plan did not include any drainage design calculation or profiles for the proposed storm sewer system. I would suggest that they also be submitted and approved prior to site plan approval. EROSION AND SEDIMENTATION CONTROL 1. A construction entrance is included in the plan. 2. Inlet protection is shown at most inlets. It is recommended that inlet protection be provided at inlets 31, 29, 27, and 25. 3. It is not clear what is proposed for the existing culvert under Route 522. If it is to remain, I recommend that inlet protection be provided there as well. 4. It appears that silt fencing will be needed along the Northern and(Eastern boundaries.l 11 11240 Waples Mill Road Fairfax, Virginia 22030 703.385.3566 Telefax 703.359.6670 ENGINEERS ARC141TECTS SCIENTISTS Page 2 February 27, 1990 Evan Wyatt 17555.059 With the inclusion of the above comments, I can recommend that the above E & S Plan be approved. Sincere y D OHU & ASSOCI S Paul A. Bernard, P. . Project Manager PAB/jla cc: Robert Oliver - Mills, Oliver & Webb, Inc. file:17555.059-fredco ENGINEERS ARCHITECTS SCIENTISTS 40 Waples Mill Road Suite 100 Fairfax, Virginia 22030 703.385.3566 Evan Wyatt, Planner Frederick County Planning Dept. 9 Court Square, P.O. Box 601 Winchester, Va. 22601 Your Authorization: Signed Agreement @Mow 2.�19V N �D ate February- 271990 Please Reference: Project No. 17555.059 Invoice No. 9002020 Client No. 07534 E. Frederick Elementary School Erosion & Sedimentation Control Plan Review Project Manager 1.0 hrs @ 33.25 33.25 Senior Engineer 2.5 hrs @ 33.25 83.13 Admin. Assistant .5 hrs @ 14.50 7.25 Total Direct 123.63 Total Indirect 185.44 TOTAL DUE THIS INVOICE $309.07 - P. 01 * TRANSACTIUN REPORT * FED-27-90 [UE 9:39 * .* � U�TE START SENDER RX T(ME PACES NOTE * 9�17 17854��5071 1"47'' 3 OK * v1"*****4:*^****��+-*:+:*+*^*r*+*******+i*+.+*+4+^*+*'�j*.++.�+***********t� FER '`_O 09: --- 1 LCjr--j )HUE S It,IG F. 1%3 t ..:Ie" W !'N01?aZBRi PLEASE DELZVM THE FOLIA ING DAGZ 5 TO 11240 V4-,.I ii ::UlA . � 'k� �a �iGR� d ,� �� ` --►� �-► :_� Cr{�! . � .�� , � �� f � ti l Al � � J � �- ,Lr f_`r c✓ Suite. Im' NO, ....�........,,..rym:.:...� ..,e:....,. ...,—,.,,.....,.....ww..s.m�...�...-_.,,�.r.�......,.,.�,,.,..,....,.._., _. _.,._,......_...�.x.� Cr4.d3.84s.L�..r R;}YL.. • �-..-wau... rs w . ou�wu..•. crwar.i�+�+'s..�i�.ran.a.�-s•+n.Mwrn�.raver.nrweis+sr..s....c......a«.....u.- - .. pRO3-- MS CC-"JR OR --Y' : CM :10' NZOT R�2 .L Cy '."*!t sit . TAX (703) ,185--8319 FEB 2 ' 90 Oq : DONOHUE P I NG R . 2/ ~'ebrudry 27, I990 Evan Wyatt, ?)l.znner Frederick county i)ept . of Planning & Development 9 CourC_ Square, P.C. t Box E 0l xh4%1I:k'.c.:a � :.1'�+�°�dh.:st*:?r", Va. 2:'t601 , wM£Yi1'1i1" Re: E. Frederick Elementary school L.D, > 005-90 2-7555.059 bear. Evan, I have reviewed the Eros icr and Spd iment Control, Plan for the above referenced project, I r f f er the foll©wl' ng COMMentS 371d 1c mxrend; t�.r�r;s. H:7 k1 1. The submittect �.l.,z�t� ca.ici r-ot itncl.ude any drainage des' gt; ca:l cu? at i on or prof i, ? ens for the proposed storm sewer system, I wOul d suggost that they also be submitted and approved prior to site plan I. A construction entrance is included in the plan, P.-Ot-e=ticn is shown at rnot.t 4 rRj,�ts. it i. s : eBO'Ommendc�d that inlet pro't:ecti o.r, be p ovided at 3. It is not clear whaT_ is proposed for 1-l-je existing cUI VO -t Urider Ra,.atcj 5 � . If it -- 0 rezuain, I re--ortmend. that inlet protection be p r o v i de,; t:he-re aC, wNa. -? . 4. It app�:ars that salt fenOing wi!.l be nPoeded along thta Northern and Eastern boundaries. a IJ240 196ples Mar Abad rvirAx, Prgi,uu 22030 703, $&.5 3566 T lei r 703.359,6670 rMa 2 ---J@ 09: 1-7, D"h0HUE S It-o-, 0 P. 3113 Page 2 0 February 27, 1990 Evan Wyat*, 17555.059 W.Lth the ir1Q1iUsj-0b of the above ca�r). r9c0MMRx*-'d that the Dove E � S Plan be, apprv--:� od, ' DgNQHTJF,,-/& ASSOCI S "ATE Paul A. pr,oject Man-ager PAB/ ji 4 cc: Robert 011.ver - mills, Oliver & Webb, inc., file: 17555.059-fredco *L Project Contents C-4,L.r. v SAT i ON S. MILL*LIVER & WEBB, INC. ARCHITECTS • ENGINEERS Date Z �% g Comm No. 9647 Cal. By Ckd. By Sheet No. 6 1'I2- = = S. �CQ (� e. 5� YP z `7. s ' kjqlz Jo Y? 6,'4 ' NIP ry t o= 8.II AczE �Q � 14.53 cis 3'- (�'" l N67 L-C i 17��V t�l Ou i rA L A _ 4, Z 4�E Q =L(l� Q - (0,-7 -7 •73`7 Q = 7, 74 cam., G. 7-8 Ate, ,-z,> � 9. 7> C= c5, s 1 2--7 Q = C t 4. 2 9 , CO Z G� a Project Z=a.u;T i!r_t. 'rY..CT' �5-- 1`�l Contents PTO �r� t-1 a l�A.l`lA G Ak MILL LIVER & WEBB, INC. ARCHITECTS • ENGINEERS Date B �c� f 11�3 9 Comm No. g a,4 -7 Cal. By ��_ Ckd. By Sheet No �lE;�2t�rl� FlAv�f T:11-A? tom- v M7 = O -A 7 A�- �,1.� ToTA tr = I Z- XC:�-'E 3.Iz Q= CtA a = C --69) C Q = `7,2.& c S 157t)7-t v-rf r e 7 /I t-I� G EM �—r1'i � 'cSl �-1 eS Q = /4 , 4o c C- _ o. -Sq GL-d- b = Cc�rLST -f.fTS �r uC� p �t �E:P— c-e 14, 5-5 �j( ._` 3 , O S � v, � n � i �•i:.r'• ., - ..� r }..; v �(Y'(- � .1y;;' iv,!. c.._ i 51 0 Project Contents ��Nl• G MILL*LIVER & WEBB, INC. ARCHITECTS • ENGINEERS Date a Comm No. la �i4 7 Cal. By Ckd. By Sheet No. _ ci--i;a, A 7 3) 1 S• 14 cA v0 Lv M "R +- 0* { G V�� - p c- CIO .4- —��— �/ _ I ► ��(2 g.39) + ( i 5, 14) a Q- Z �- 1/ = 1'0-1-7Z.-/B4-+3 x 4. 5' A-t- -T�`P vim, -t--4 tY AND A or-- 4.5' it-4 —rt+E CEkTc P, +`T�OV I'C7 1, ..VD V -' �j z 00 >rT FOR AN OvT LET uSE 60' 1E3���F (2) O,©27 70 Project Contentsu15� �o GA,��Jt_ATtiO�.s. S . Ale - a. MILLObLIVER & WEBB, INC. ARCHITECTS • ENGINEERS C Date 7Z 7f _ -Comm No. Cal. By Ckd. By Sheet No. '4 S �A'z t1c, !­o -T- ahl 7 =8 M174, P02 = . 5 1 x g. -:54 'Cs, co = ZI,-2-'7 ma's �� r�G— 'tic cak•� = cll �"� 2 1, -2 —7 _ gyp, t 2 -d-c — V�osITi—=- c = 6),-S9 =c�4.a9(4j(�.lz� L--D o,,4- PA-67A'�/ M �rtdt�r7 TEAK l Ida=,mow �`-Iv�,�Cr� 9� q 7 i 0 Project Contents 7-7-Y Date — Cal. By MILL*)LIVER & WEBB, INC. ARCHITECTS • ENGINEERS Comm No. Ckd. By Sheet No. �a cb - 14 4/ > 6 = 1( _3 , -7 = i9,ao ces 14 Tz`C F s�tit I lo` So' \,S,// s iDz-= nwr� r_-PTvt eao } l -Z Z4 JP+ _' �20 }� _- 0vT L L--'T- 'D G.J (c_ G Zi AMC=Z&%e, .,,� ����r�� wt►R � n-f — �S' c��, — &65100 9vdrogfao§ lime\\�comcentea%ior Storm duration =2g.4 Time \// e.00 1.0 1.90 2.0 3.80 222 5.71 4.0 7.G± S. @ -3.51 G.0 11.4! 7.0 13.31 222 15.22 9.0 15.22 !e.@ 15.22 11.@ 15.22 i2.e 15,22 !3.0 15,22 !§.§ 15.22 l5.2 l5.22 16.@ 15.22 .222 15.22 1B.e 15.22 19.0 15.22 2@.0 15.22 2±.@ ««•2 15. 22 :3.0 15.22 /§.0 15.22 :5.0 15.22 \G.0 l5.22 27.0 ±5.22 2B.0 15.22 2g.0 15.22 30.0 14.53 31.0 13.39 32.3 12.2E \3322 4.0 g,9b 35.0 e,84 36.0 7.70 37.0 6.56 39.0 5.42 .222 4.2E §222 3.14 41.0 2.00 42.0 0.87 9 = 8.0 m!n in Hydrogrz Time of Storm di Time (min) 0.0 }.@ 2.0 3.2 4.0 S. @ G.G 7.0. 8.0 9.0 10.0 ii.0 M.0 A.0 14.0 15.0 16.0 17.0 is.0 19.0 20.0 27.0 22.0 24.@ 25.0 26.0 27.0 28.0 29.0 30.0 31.0 32.0 33.0 34.0 35.0 36.0 37.0 38.0 H ROUT VERSION 5.. 4 PRO..i L' i . BB47 E5YR DE.`.^.IG!'`i i^: •r• DATE: 9/1EMS89* #: #: •3C #:•#-k•�•�-#:-•;<-?:-•�•?( #: •�d'-#:.`;.•i{�.#;•�•ic•r••#: fi.#,_.�,..�..�:..�..K.�.�_.�..y,..#..�--=: #:•#: -iF# �T-#i•1<-•Y: #::F.•i: #=#: #: -Y•#:�-�•#-_•#� #: -ii••�•x• k•f:'=;(-�-#=-i4'-K•#: -F•�•-'t.•'1=K•# (Types: Me'ir; 2:Pipe; 3:Riser) Structure 1 1: Type 2: Pipe Weir: 2: Elevation (ft) 0.00 3: Length (ft) 0.00 4: Coefficient 0.00 Riser: 5: Elevation (ft) 0.00 6: Inlet Area (sf) 0.00 7: Inlet Perimeter (ft) 0.00 8: Orifice Elevation (ft) 0.00 9: Orifice Diameter (in) 0.00 10: Orifice Elevation (ft) 0.00 . . Orifice Diameter (in) 0.00 12: Dr i•i ice Elevation (ft) 0.00 M Orifice Diameter (in) 0.00 Pipe: 1 : invert Elevation (ft) 81.50 152 Diameter (in) 18.00 16: Orifice Diameter (in) MOO 17 : Length (ft) 60.00 .8: Manning' s r-, 0.010 19: Slope (ft/ft) 0.087 20 : Entrance Loss Coefficient 0.7 Surface: 21.: Initial Elevation (ft) 81.50 Storage Pond Characteristics: Section Elevation Area ------------------------------ (ft) (sg ft) 1 81.50 0.00 L 82.00 1700.00 3 84.00 3070.00 4 86.00 4725.00 Control; RW = Riser actinn as a weir-. RD = Riser acting as an orifice PI = Horizontal pipe in inlet control. 'O = ,Horizontal pipe in outlet control Time Inflow Pipe Total Elev Storage (min) ------------------------------------------------------ (cfs) (cfs) (cfs) (ft) (cu ft) 0.0 0.00 0.0 0.00 81.50 0.00 1.0 2.46 0.2 PI 0.18 81.66 73.14 2.0 4.93 0.7 PI 0.68 81.87 267.51 3.0 7.39 1.5 PI 1.52 82.11 584.84 4.0 9.85 2.6 PI 2.60 82.36 987.28 5.0 12.32 3.9 Pi 3.90 82.61 1,4S3.58 6.0 14.78 5.4 PI 5.38 82.85 2,002.37 7.0 17.24 7.0 PI 7.02 83.10 2,593.93 8.0 19.71 8.8 PI 8.80 83.34 3,229.S4 9.0 19.71 9.6 Pi 9.56 83.57 31SS3. 19 10.0 19.71 10.2 Pi 10.17 83•. 76 4,455.12 11.0 19.71 10.7 PI 10.69 83.94 5,012.68 .L L ' ' 'n 0 19.71 11.2 PI 1 1. 16 84.10 5,540.02 Q. 0 19.71 MG PI 11.59 84.25 6. 040. 39 14.e 19.71 12.0 Pi 11.97 84.39 6,516.40 15.0 19.71 12.3 PI 12.30 84.51 6,937.50 16.0 19.71 12.6 Pi 12.60 84.62 7,341.88 17.0 i 9. 71 12.9 PT 1 L. 89 64.71 71730.62 2a.w 19.71 21.6y 19.71 ~22.0 19.71 23.0 19.71 24,0 19.71 25.0 19.71 26.0 19.12 27.0 17.64 28.0 16.17 29.0 14.69 30.0 13.22 31.0 11.74 32.0 10.27 33.0 8.79 34.0 7.32 35.0 5.84 36.0 4.37 37.0 2.89 IS. 6 iD i 13^ 6� uNN� 13.9 PI���13.86 14.1 PI 14.06 14.3 PI 14.26 14.4 14.6 14.8 14.9 15.0 15.0 14.9 14.9 14.7 14.5 14.3 14.0 13.6 13.2 41" PI PI PI PI PI PI PI PI PI PI PI PI PI PI 14.45 14.63 14.79 14.91 14.97 14.99 14.95 14.86 14.71 14.51 14.26 13.95 13.58 13.18 Au-Ow=/6" s 4 85.0l 85.09 85.17 85.25 85.33 85.40 85.46 85.51 85.53 85.54 85.53 85.49 85.43 85.35 85.25 85.13 84.99 84.84 8,812. 9114S.9101 9,470.05 9,782.10 10,083.59 10,375.04 10,640.45 10,839.71 10,950.49 10,979.50 10,914.02 10,757.80 10,514.40 10,187.25 9,779.68 9,295.03 8,736.64 8,150.77 G ROUT VERSION 5.4 PROJECT: DATE: 9/16/1989* •� �• �• �• �• •�--x••�• •x• �t• it• •�• •x•-li• •x--x• •� •x-•�• �. •�• •x• �..� •*• •x• •�• •�. •�• �..�..� •�. •�•.p. •* -� •x••� at• it• a4• •x• •rF � •x• aE• �. •x• •�. •x• aE• •�• •x• -� •�• -x• -x• -� �• •x• �• •x--�• •�• •� �• •�• •� •?E• aa.• •� •�• �•-� �• a�• -� (Types: 1 :Weir,; 2:Pipe; 3: Riser,) Structure 1 1: Type 2: pipe Weir: 2: Elevation (ft) 0.00 3: Length (ft) 0.00 4: Coefficient 0.00 Riser: 5: Elevation �n (ft) 0.00 6: Inlet Area (sf) 0.00 7: Inlet Perimeter (ft) 0.00 8: Orifice Elevation (ft) 0.00 9: Orifice Diameter (in) 0.00 10: Orifice Elevation (ft) 0.00 11: Orifice Diameter (in) 0.00 12: Orifice Elevation (ft) 0.00 13: Orifice Diameter (in) 0.00 Pipe: 14 : Invert Elevation (ft) 81.50 15: Diameter (in) 18.00 16: Orifice Diameter (in) 18.00 17: Length (ft) 60.00 IS: Manning' s n 0.010 19: SlOpe (ft/ft) 0.027 20: Entrance Lass Coefficient 0.7 Surface: 21: Initial Elevation (ft) 81.50 Storage Pond Characteristics: Control: RW = Riser acting as RO = Riser acting as PI = Horizontal pipe PO = Horizontal pipe Section Elevation Area (ft) (sq ft) ------------------------------ 1 81.50 0.00 2 82.00 1700.00 3 84.00 3070.00 4 86.00 4725.00 a weir an orifice in inlet control in outlet control Time Inflow Pipe Total Elev Storage (min) (cfs) (cfs) (cfs) (ft) (Cu ft) ----------------------------------------------------- 0.0 0.00 0.0 0.00 81.50 0.00 1.0 1.90 0.1 PI 0.14 81.64 37.36 2.0 3.80 0.5 PI 0.52 81.82 207.20 3.0 5.71 1.2 PI 1.17 82.02 453.93 4.0 7.61 2.0 PI 2.00 _ 82.23 765.97 5.0 9.51 3.0 PI 3.00 82.44 1, 134.98 6.0 11.41 4.1 PI 4.14 82.65 11552.51 7.0 13.31 5.4 PI 5.40 82.86 21010.95 8.0 15.22 6.8 PI 6.77 83.06 21503.83 9.0 15.22 8.1 PI 8.08 83.25 2,972.73 10.0 15.22 9.0 PI 9.02 83.39 3,372.44 11.0 15.22 9.4 PI 9.42 83.52 3,732.98 12.0 15.22 9.8 PI 9.78 83.64 4,070.54 13.0 15.22 10.1 Pi 10JJ�� . 07 83.73 41357.46 14.0 15.22 2 10.3 PI io. 33 8�.3. 82 4,630.08 15.0 15.22 10.6 Pi 10. 58 83.90 4. 889. 46 2 l -' - - 37 i'. - 73 5 357. 'SA C, .I.M 0 15.22 .�.v'.:. 6 -t. lei. 58 83.30 S8S. 46 16.0 15.22 10.8 .- I 10.81 83.98 5, 136. 54 17.0 15.22 11.0 Pi 11.02 84.05 5,372. 15 A. 0 15.22 1 1. 2 PI 11.21 84.12 5,597.04 19.0 15.22 11.4 PI 11.40 84. 19 5, 811. 88 20.0 15.22 11.6 PI 11.57 84.25 6, 017. 28 21.0 15.22 11.7 PI 11.73 84.30 6,213.80 mac. 0 15.22 11.9 P I 11.88 84.36 6,401.93 23.0 15.22 12.0 PI 12.03 84.41 6, WE 15 24.0 15.22 12.2 PI 12.16 84.46 6, 754. 89 25.0 15.22 12.3 P I 12.29 84.50 S1920.54 26.0 15.22 12.4 PI 12.41 84.55 7, 079. 46 27. 0 15.22 M. 5 PI 12.52 84.59 7, 232. 01 2810 15.22 12.6 P 12.63 84.63 7.37S.49 29.0 15.22 12.7 Pi 12.73 84.67 7,519.20 30.0 14.53 12.8 8 P i 12.82 84.70 7, 635. 76 31.0 13.39 12.9 DI 12.86 84.72 7, 698. OF, 3& 0 12.26 12.9 I -'I 12.86 84.72 7,695.54 33.0 11. 12 12.8 PI 12.81 84.70 7,S19.94 34.0 9.98 12.7 PI 12.70 84.66 7,474.02 35.0 8.84 12.5 PI 12.55 84.60 7l263.49 36.0 7.70 12.3 PI 12.34 84.52 6, 989. 16 37.0 6.56 12.1 Pi 12.08 84.43 S,654.92 38.0 5.42 11.8 PI 11.77 84. 32 6, 2G3. 85 39.0 4.28 11.4 PI 11.44 84.20 5,S58.27 40.0 3.14 i 1. 0 PI i 1. 05 84.06 5,405.91 41.0 2.00 10.6 PI io. 6o 83.91 4,910. 15 NAME: STORM SEWER DESIGN COMPUTATIONS FILE NAME: SSDC INPUT BY: AWH DATE ORIGINATED: 9 JAN 1987 DWG SCALE: FULL COMPUTATIONSSTORM SEWER DESIGN STORM• • PROJECT: � s ■ NED BY: ■ • s • MMWM mm _--�__ __----- o = �� •. . , r. ©a©cam ' _ .mlms�mm mom =oama©■any : ® �® - . _ ; ... - 0 MILLWIVER & WEBB, INC. ProjectC1 �(1�( �jG<< ARCHITECTS • ENGINEERS L1`'1 SC. Date 61/2- / 8 9 Comm No. 8 4 7 Contents Z72�( - Cal. By Ckd. By Sheet No. =rtr�r-�atr�( $A�e� Dry. !o-Y2 SeaQ�t 5 MIN & 1-i t, Z +:�1 � �M -F- �, z S • � .4 � � • Ltd = 5 8 z , 8 �_��- 0, o r 7S ,4' 7-07-A-i- God�t.PoScT� C. L6t3 (M) t ,f4,3)1 11' G= 0-35 �.=CtA = (,3S)(6,g�C.rs3) Q = Q, 3& cis iC F�/ t 1 i 5. w—> / Z s s. It r-T - = 6 . Z 04 A-z- 00 z. 4 q S, Z. P7- 2- = G . Z S -7 Cpf"lPo�cvG C - p•CPO c4l's 3,� GYM . 1.4s7. /(c-cD = 3 9 /6,Q F-Tz - co, 0 90 A C7� SS, �,.�1 �� s 3 Z970 F z = ©, D-75 A - Go M i�o� ��. C— _ � • �3 27,) �YNI 3,95 - 'FZ0 9 . z r Tz O , Z i I l� ��, s • S -VO - ,-fir 7 • ( = 1 Z ZG Z '1 Z _ 0. Z 0 ��- ��f ZIL�Q bo- b pz-'-z 02- s Z b-Z= S 9' z 1 S3-Z �9 ('621 <--p r:' -k &OZ Or 'ON laauS A8 'PmoA8 'IEo slualuoo L 88 'ON WwoO 69177 S a}�� Sa33NION3 • S103llH08V � , -�- 'Q�ZI—I 1091oad �N1 883M'8 -IM 51'71 Qv9, NAME: STORM SEWER DESIGN COMPUTATIONS FILE NAME: SSDC I11PUT BY: AWH DATE ORIGINATED: 9 BAN 1987 SCALE: FULL STORM SEWER DESIGN • • • NS STORM• • " PROJECT: ► s • •• • s PROFILE • • Project E ,6'-S-TM-'�l MILL-OLIVER & WEBB, INC. ARCHITECTS • ENGINEERS Contents 1�At fit d.C7 Date S / 8 Comm No. e 64 7 Cal. By Ckd. By Sheet No. -BAtSED C ,hA 10-YZ- 5Tor-M, 5Mit1 11`A r��F�lG1C Le• 1.5. 2.3 z 3 31. z) = 3 S 5 0 4. 18 i Z = p . g AL ►=1(a� C-� ,z��s o . °Io (Z33 I. z) = Z o 8 Frz = c2 0 4 8 A� 7aTAcL. O. 86,6 Q = 0.87 /S- p.zoCc Q=c-ti,' _ .S7��Cfl.Q,)� •8G3) Ile -c�.b `1 p l = 3. 89 -PV►A t = 11-4G (z�3t.Z) = 2� 7/S. �� rig = Q. (0 / 3 1,4GRASS' 6,523 31.Z) = I 008. 0 9 t=cZ = o E�Co C_Oi-•t-I----'OSITE- r = 0.7DZ8 p,70 -PVM-F.. Z.. /9 ' ( 2331,Z) _ 4908.77 �-Z � 0 • ! ( S AC- 1 C-r sue' 7.�0� �Z331.Z� = / 771 7.1 F7Z = 0.40 `7 ,lc - Co r -P-5- rr-- <f- = 0 . 4 3 Q = c- 4--3) Q=1,s3 Cps [LiEmEnk F umz�m nmuuvu- MILLS, OLIVER & WEBB, INC. ARCHITECTS ENGINEERS ORIGINATED FROM: 200 COUNTRY CLUB DRIVE 0 PLAZA 1, BUILDING E BLACKSBURG VIRGINIA 24060 703/552-2151 703/951-0219 (FAX) P.O. BOX 1553, 1422 MAIN STREET PRINCETON, WEST VIRGINIA24740 304/425-6788 Frederick County Department of Planning & Development P. 0. Box 601, 9 Court Square Winchester. VA 22601 DATE 12/11/89 1 JOB NO, 8847 ATTENTION Mr. Evan Wyatt RE Eastern Frederick I Elementary School GENTLEMEN: WE ARE SENDING YOU M Attached ❑ Under separate cover via ❑ Prints ❑ Specifications ❑ Copy of letter ❑ Change order ❑ the following items: COPIES DATE N DESCRIPTION 3 a- Site Plans C I :tIIt" C 1 Storm Water Calculations THESE ARE TRANSMITTED as checked below: l For approval ❑ For your use ❑ As requested REMARKS Dear Mr. Wyatt: COPY TO ❑ For review and comment p Request for site plan comments have been submitted several weeks ago to the following: 1. Frederick County Sanitation Authority - Approved October 31, 1989. 2. Virginia Department of Transportation - Have not vet received their comments. SIGNED: If enclosures are not as noted, kindly notify us at once. ip/P�ppas, AIA • [LiEum' (wuM'uz1uUUaL Frederick County Planning Department MILLS, OLIVER & WEBB, INC. ARCHITECTS ENGINEERS P. 0. Box 601 ORIGINATED FROM: 200 COUNTRY CLUB DRIVE 0 PLAZA 1, BUILDING E BLACKSBURG VIRGINIA 24060 703/552-2151 703/951-0219 (FAX) P.O. BOX 1553, 1422 MAIN STREET PRINCETON, WEST VIRGINIA24740 304/425-6788 9 Court Square Winchester. VA 22601 DATE 12 6 89 JOB NO. 8847 ATTENTION Bob Watkins RE Eastern Frederick I Elementary School GENTLEMEN: WE ARE SENDING YOU [k Attached ❑ Under separate cover via the following items: ® Prints ❑ Specifications ❑ Copy of letter ❑ Change order ❑ COPIES DATE NO. DESCRIPTION 1 %il Site Plans (Cl—C9) THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ For your use (i As requested Nl For review and comment Q REMARKS COPY I— -- SIGNED: If enclosures are not as noted, kindly notify us at once. P lip Papp AIA ADDENDUM NUMBER 1 EASTERN FREDERICK I ELEMENTARY SCHOOL FREDERICK COUNTY, VIRGINIA JANUARY 5, 1990 MILLS, OLIVER & WEBB, INC. ARCHITECTS ENGINEERS BLACKSBURG VIRGINIA THE FOLLOWING ADDITIONS, DELETIONS AND/OR CHANGES SHALL BE INCORPORATED INTO THE DRAWINGS AND SPECIFICATIONS AND SHALL BECOME A PART OF--UE CONTRACT DOCUMENTS. DRAWINGS A —8 SHEET A6 - FINISH SCHEDULE LJ �_. GYMNASIUM - CHANGE FLOOR FINISH TO WOOD AND BASE TO RUBBER SPECIFICATIONS SECTION 4C - BRICK MASONRY PAGE 4C-5 OMIT PARAGRAPH B AND ADD: CLEANING OF BRICK AS PER MANUFACTURER RECOMMENDATION SECTION 8C - WOOD DOORS PAGE 8C-1 ADD: 5 PLY OR 7 PLY WOOD DOORS ARE ACCEPTABLE; HOWEVER, THE CROSS BANDS MUST BE GLUED TO THE CORE. DROP IN CORES ARE NOT ACCEPTABLE. SECTION 9D - ACOUSTICAL TREATMENT PAGE 9D-1 9D - D MATERIALS ADD THE FOLLOWING TO PARAGRAPH 3: (LOCATE IN THE FOLLOWING SPACES: 101 and 102) ADD THE FOLLOWING AFTER PARAGRAPH 5: (LOCATE IN THE FOLLOWING SPACES: 118, 121, 178, 189, 197, AND 204) PAGE 9H-1 9H - D MATERIALS ADD THE FOLLOWING TO PARAGRAPH 3: (ROOM 215 ONLY) PAGE lOG-1 10F - D MATERIALS CHANGE PARAGRAPH 3 FROM 4900 SERIES TO 800 SERIES AND THICKNESS FROM 3" to 4". SECTION 11A - FOOD SERVICE PAGE 11A - 21 DID NOT REPRODUCE LEGIBLY. ANOTHER COPY IS ATTACHED. PAGE 15C - 29: PARAGRAPH 15C - R.3 THE DISCHARGE DUCT COLLAR SHALL BE WITHIN 3/4" FROM THE TOP OF THE UNIT VENTILATOR v e. Appliance shut-off feature, with snap -action switch arranged to shut off service to equipment under hood when system is actuated. Fire control system to be as manufactured by ANSUL, (MARINETTE, lql), MODEL R-102, WALTER KIDDE, or RANGE GUARD, (CLEVELAND, OH), or approved equal. ITEM 29 INGREDIENT BIN THREE REQUIRED Provide vinyl ingredient bin having following features: a. Removable sliding lid. b. Set of four 4" diameter casters. c. Interior corners coved. Ingredient bin to be as manufactured by RUBBERMAID, (WINCHESTER, VA), MODEL 3602, CAMBRO, (HUNTINGTON BEACH, CA), or approved equal. ITEM 30 NOT USED ITEM 31 ICE MACHINE ONE REQUIRED Provide cube icemaker and bin having following features: Ice Maker a. Electrical characteristics as scheduled. b. Capacity based on 700F incoming water and 900F ambient, of approximately 400 lbs. c. Self contained, air cooled, electrical characteristics as scheduled. d. Manufacturers standard finish. e. Arranged to make half diced ice. Bin a. Bin to have rated capacity of approximately 400 lbs. b. Manufacturers standard finish. c. 6" adjustable stainless steel legs. Icemaker to be as manufactured by MANITOWOC, (MANITOWOC, WI), MODEL EY-0404A, SCOTSMAN, (ALBERT LEA, MN), HOSHIZAKI, (PEACHTREE CITY, GA), or approved equal. ITEM 32 BAKER'S TABLE ONE REQUIRED This Item to be manufactured by STANLEY KNIGHT, (NEW TROY, MI), MODEL BTS-60S, LOW TEMP, (JONESBORO, GA), MARLO, (WELDON, NC), or approved equal, in accord with plans and specifications. IIA-21 a • ADDENDUM NUMBER 1 EASTERN FREDERICK I ELEMENTARY SCHOOL FREDERICK COUNTY, VIRGINIA JANUARY 5, 1990 MILLS, OLIVER & WEBB, INC. ARCHITECTS ENGINEERS BLACKSBURG VIRGINIA THE FOLLOWING ADDITIONS, DELETIONS AND/OR CHANGES SHALL BE INCORPORATED INTO THE DRAWINGS AND SPECIFICATIONS AND SHALL BECOME A PART OF THE CONTRACT DOCUMENTS. DRAWINGS SHEET A6 — FINISH SCHEDULE GYMNASIUM — CHANGE FLOOR FINISH TO WOOD AND BASE TO RUBBER SPECIFICATIONS SECTION 4C — BRICK MASONRY PAGE 4C-5 OMIT PARAGRAPH B AND ADD: CLEANING OF BRICK AS PER MANUFACTURER RECOMMENDATION SECTION 8C — WOOD DOORS PAGE 8C-1 ADD: 5 PLY OR 7 PLY WOOD DOORS ARE ACCEPTABLE; HOWEVER, THE CROSS BANDS MUST BE GLUED TO THE CORE. DROP IN CORES ARE NOT ACCEPTABLE. SECTION 9D — ACOUSTICAL TREATMENT PAGE 9D-1 9D — D MATERIALS ADD THE FOLLOWING TO PARAGRAPH 3: (LOCATE IN THE FOLLOWING SPACES: 101 and 102) ADD THE FOLLOWING AFTER PARAGRAPH 5: (LOCATE IN THE FOLLOWING SPACES: 118, 121, 178, 189, 197, AND 204) 4 0 SECTION 9H - ACOUSTICAL WALL PANELS PAGE 9H-1 9H - D MATERIALS ADD THE FOLLOWING TO PARAGRAPH 3: (ROOM 215 ONLY) SECTION IOG - OPERABLE WALL PAGE IOG-1 1OF - D MATERIALS CHANGE PARAGRAPH 3 FROM 4900 SERIES TO 800 SERIES AND THICKNESS FROM 3" to 4". SECTION 11A - FOOD SERVICE EQUIPMENT PAGE 11A - 21 DID NOT REPRODUCE LEGIBLY. ANOTHER COPY IS ATTACHED. SECTION 15C - AIR CONDITIONING DETAILED SPECIFICATIONS PAGE 15C - 29: PARAGRAPH 15C - R.3 I THE DISCHARGE DUCT COLLAR SHALL BE WITHIN 3/4" FROM THE TOP OF THE UNIT VENTILATOR • 6 0 e. Appliance shut-off feature, with snap -action switch arranged to shut off service to equipment under hood when system is actuated. Fire control system to be as manufactured by ANSUL, (MARINETTE, WI), MODEL R-102, WALTER KIDDE, or RANGE GUARD, (CLEVELAND, OH), or approved equal. ITEM 29 INGREDIENT BIN THREE REQUIRED Provide vinyl ingredient bin having following features: a. Removable sliding lid. b. Set of four 4" diameter casters. c.•Interior corners coved. Ingredient bin to be as manufactured by RUBBERMAID, (WINCHESTER, VA), MODEL 3602, CAMBRO, (HUNTINGTON BEACH, CA), or approved equal. ITEM 30 NOT USED ITEM 31 ICE MACHINE ONE REQUIRED Provide cube icemaker and bin having following features: Ice Maker a. Electrical characteristics as scheduled. b. Capacity based on 700F incoming water and 900F ambient, of approximately 400 lbs. c. Self contained, air cooled, electrical characteristics as scheduled. d. Manufacturers standard finish. e. Arranged to make half diced ice. Bin a. Bin to have rated capacity of approximately 400 lbs. b. Manufacturers standard finish. c. 6" adjustable stainless steel legs. Icemaker to be as manufactured by MANITOWOC, (MANITOWOC, WI), MODEL EY-0404A, SCOTSMAN, (ALBERT LEA, MN), HOSHIZAKI, (PEACHTREE CITY, GA), or approved equal. ITEM 32 BAKER'S TABLE ONE REQUIRED This Item to be manufactured by STANLEY KNIGHT, (NEW TROY, MI), MODEL BTS-60S, LOW TEMP, (JONESBORO, GA), MARLO, (WELDON, NC), or approved equal, in accord with plans and specifications. 11A-21