February 12, 1988
H & W Construction Company, Inc.
P. 0. Box 2468
Winchester, Virginia 22601
Dear Sirs:
This letter is to confirm the Frederick County Planning Commission's action at
their meeting of February 3, 1988:
Approval of Site Plan #060-87 of Jones and Frank Oil Equipment, zoned M-1, for a
wholesale oil distribution parts building, located in the Fort Collier Industrial
Park, in the Stonewall Magisterial District.
Prior to final approval by the staff, fire hydrant location and drainage
information will need to be submitted for review.
If you have any questions regarding your site plan, please do not hesitate to
call this office.
Sincerely,
Robert W. Watkins
Planning Director
RWW/dkg
9 Court Square - P.O. Box 601 - Winchester, Virginia - 22601
SITE PLAN #060-87
Jones and Frank Oil Equipment
Zoned M-1 (Industrial Limited)
LOCATION: Fort Collier Industrial Park
MAGISTERIAL DISTRICT: Stonewall
ADJACENT LAND USE AND ZONING: Industrial land use and zoning
PROPOSED USE AND IMPROVEMENTS: Wholesale oil distribution parts building and site
improvements.
REVIEW EVALUATIONS:
Dept. of Transportation - The entrance location meets our requirements for
sight distance. We will require a minimum entrance width of 50'. The
drainage culvert shall be 15" in lieu of the proposed 12". Before any work
is done on the right-of-way, a land use permit must be applied for and
approved.
Sanitation Authority - 1) Sewer line to be 4" minimum. 2) Might consider
water line to be 2". 3) Existing water line approximately 100' to the West.
If line brought across intertype, you will need easement. Will need gate
valve at tap. Sanitation Authority will be responsible for line to gate
valve.
Clearbrook Fire Company - No comment.
Building Department - Shall comply to Use Group S-1 (storage uses) - moderate
hazard, Section 310.2 of the BOCA Basic National Building Code 1984.
Planning and Zoning - No objection. The proposed site plan meets all
applicable site planning and zoning standards for this warehousing use. The
fire hydrant must be located as per Sanitation Authority drawing.
STAFF RECOMMENDATIONS: Approval.
14
f42 43
„o ,n on , �� _. i•
r i .
A- � d p �� � • to r � � n
p RP -_ , �,o RIP
I d Rp
A AL
a 5 NI w
RP
(w 53 2
IRP Ir
A.2
CITY OF
/ WINCHESTER CITY OF
H t / WWCHEST.ER/.\ p.
TO:
Clearb
.� 16171819�0
r
lire Co pang
COUNTY of FREDERICK
Departments of Planning and Building
M E M 0 R A N D U M 703/665-5650
Virginia(',Aep#X,,tznent of Transportation
r
Sanitatio �cithority
-Inspections Depiiltment
ATTN: Mr. Tommy Price
ATTN: Mr. William H. Bushman
ATTN: Mr. Wellingthon Jones
ATTN: Mr. Kenneth L. Coffelt
Planning and Zoning Department , ATTN: Mr. Stephen M. Gyurisin
FROM: Robert W. Watkins, Director DATE: January 5, 1987
SUBJECT: Review Comments On: Conditional Use Permit X Site Plan
Master Plan Rezoning _ Subdivision
We are reviewing the enclosed request by Jones & Frank Oil Equipment ,
or their representative, H & W Construction Company, Inc. 667-3752 -
Will you please review the attached and return your comments to me as soon as
possible.
THIS SPACE SHOULD BE USED FOR REVIEW COMMENTS:
THE ENTRANCE LOCATION MEETS OUR REQUIREMENTS FOR SIGHT DISTANCE, WE
WILL REQUIRE A MINIMUM ENTRANCE WIDTH OF 50'. THE DRAINAGE CULVERT
SHALL BE 15" IN LIEU OF THE PROPOSED 12", BEFORE ANY WORK IS DONE
ON THE RIGHT-OF-WAY, A LAND USE PERMIT MUST BE APPLIED FOR AND APPROVED, I
SignatureDate
9 Court Sauare - P.O. Box 601 - Winchester, Virginia - 22601
e
COUNTY of FREDERICK
Departments of Planning and Building
M E M O R A N D U M 703/665-5650
T0:
Clearbrook Fire Company
, ATTN:
Mr.
Tommy Price
Virginia Department of Transportation
, ATTN:
Mr.
William H. Bushman
Sanitation Authority
, ATTN:
Mr.
Wellingthon Jones
Inspections Department
, ATTN:
Mr.
Kenneth L. Coffelt
Planning and Zoning Department
, ATTN:
Mr.
Stephen M. Gyurisin
FROM: Robert W. Watkins, Director DATE: January 5, 1987
SUBJECT: Review Comments On: Conditional Use Permit X Site Plan
Master Plan Rezoning Subdivision
We are reviewing the enclosed request by Jones & Frank Oil Equipment ,
or their representative, H & W Construction Company, Inc. 667-3752
Will you please review the attached and return your comments to me as soon as
possible.
THIS SPACE SHOULD BE USED FOR REVIEW COMMENTS:
Signature
to �' 7—�4
9 Court Sauare - P.O. Box 601 - Winchester, Virginia - 22601
W
M E M 0 R A N D
TO:
COUNTY of FREDERICK
:Dq _vtments of Planning and Building
( - q J41V
• 7 / ..
Clearbrook Fire Company ATTN1.11r. Tommy Ptf4e
Virginia Department of Transportation ATTN: (,. William H,,'!L6shman
Sanitation Authority ATTN: Mr. 963141tigt` On Jones
Inspections Department , ATTN: Mr. Kenneth L. Coffelt
Planning and Zoning Department , ATTN: Mr. Stephen M. Gyurisin
FROM: Robert W. Watkins, Director DATE: January 5, 1987
703/665-5650
SUBJECT: Review Comments On: Conditional Use Permit X Site Plan
Master Plan Rezoning Subdivision
We are reviewing the enclosed request by Jones & Frank Oil Equipment ,
or their representative, H & W Construction Company, Inc. 667-3752
Will you please review the attached and return your comments to me as soon as
possible.
---------------------------------------------------------------------------------
THIS SPACE SHOULD BE USED FOR REVIEW COMMENTS:
7-0
•?. •Ct �'ff T C'C�il/ S /a fP go / /4//= To S,, o?
3 Erg57//// 7o
/F
IA//LL 67WK 1 i / VF ,4 T 74 1;. 5,AV1T/4 T / olv
lA//Lt SF �FSF�oirS/13<F /`=vim 7-0 1/�L VX-
Signature Date ✓ 4W Cope
9 Court Sauare - P.O. Box 601 - Winchester, Virginia - 22601
I RECIPIENT COPY (WHITE)
Urbaff.
TO: County of Frederick, Dept. of Planning and Development
107 North Kent Street, Suite 202
Winchester, VA 22601-5000
ATTN: Candice Perkins
® ORIGINALS
❑ SPECIFICATIONS
❑ COLOR PRINTS
DATE:
JOB #:
PRINT TICKET #:
PLANNERS
ENGINEERS
LANDSCAPE
ARCHITECTS
APR 1 8 LAND
SURVEYORS
April 18, 2007
05-018
8529
RE: Meadows Edge Collector Road Plan
TRANSMITTED HEREWITH:
® PHOTOCOPIES ❑ CD ® BLACKLINE PRINTS
❑ COMPUTATIONS ❑ INVOICE ❑ MYLAR PRINTS
❑ SITE NOTICES ❑ OTHER
QUANTITY
DRAWING NO.
DATE
DESCRIPTION
1
PP-20129
2/23/07
Construction Plans and Profiles - Meadows Edge Collector Road - Approved
Set
1
3/8/07
VDOT Approval Letter from Lloyd Ingram - received via e-mail on 3/8/07
1
4/16/07
Approval from Town of Stephens City
1
6/2/06
FCSA approval written by John Whitzcre on a transmital form - approved
6/12/06
1
1 /16/07
Approval Letter from Frederick County Public Works
1
1/16/07
Letter from FEMA approving the Conditional Letter of Map Revision for
floodplain alteration
1
3/8/07
Letter from DEQ approving the closure report for the Town of Stephens City
wastewater lagoon
FOR: ❑ SUBMISSION
❑ FIELD USE
SENT BY: ❑ FIRST CLASS MAIL
PLEASE: ❑ RETURN
COMMENTS:
❑ RESUBMISSION ❑ INSERTS
® YOUR FILES ❑ COMMENTS
❑ OUR MESSENGER ❑ PICKUP
❑ SUBMIT
❑ APPROVAUSIGNATURE
❑ OTHER
❑ COURIER ❑ OVERNIGHT
❑ OTHER
RECEIVED BY: SENT BY: �2ataQlitt �f. $clusudt
RECIPIENT COPY (WHITE)
Urban, Ltd. 210 Front Royal Pike Winchester, Virginia 22602 PH 540.450.0211 FX 540.450.0210 www.urban-ltd.com
Annandale, VA Chantilly, VA Winchester, VA Wilmington, NC
[ctow's Edge Collector Road, Route 1012, Fl-ederic County Page 1 of 2
Schmidt, Natasha
From: Funkhouser, Rhonda [Rhonda.Funkhouser@VDOT.Virginia.gov] on behalf of Ingram, Lloyd
[Lloyd.ingram@VDOT.Virginia.gov]
Sent: Thursday, March 08, 2007 10:45 AM
To: Schmidt, Natasha
Cc: Baluch, Stephen; Ingram, Lloyd
Subject: Meadow's Edge Collector Road, Route 1012, Frederick County
This is to acknowledge receipt of your revised plans with latest revisions dated 2/23/07 for the
referenced project. The plans appear satisfactory and are approved. Please advise the
developer accordingly. Please provide 6 sets of approved construction plans with
signed seal for VDOT distribution.
I offer the following comments:
• A. preconstruction conference be held by the engineer and/or developer with the
attendance of the contractor, various County agencies and VDOT prior to initiation of
work.
• Materials used and method of construction shall apply to current observed VDOT Road &
Bridge Specifications applicable during construction of this development.
• Our review and comments are general in nature. Should conditions in the field exist
such that additional measures are warranted, such measures shall be completed to the
satisfaction of the Department prior to inclusion into the Secondary Road System.
• Attached is a copy of the minimum requirements and information needed prior to
acceptance of subdivision streets into the Secondary System. This is the responsibility of
the developer.
• All drainage is to be carried within the right-of-way in ditch lines or gutters along the
street to a pipe or drainage easement.
• As required in the VDOT general notes, the contractor shall report findings of foundation
exploration to the engineer and VDOT for approval prior to construction of the proposed
box culvert ME/1-ME/2.
• The contractor shall notify VDOT when work is to begin or cease for any undetermined
length of time. VDOT will also require 48 hours notice for inspections.
• The appropriate land use permits shall be obtained before any work is performed on the
State's right-of-way. The permit is issued by this office and will require a minimum
processing fee, surety bond coverage, and the salary & expenses of a State assigned
Inspector.
• If mailboxes are to be placed along the roadway fronting lots, a minimum of 4' shall be
between the edge of pavement and the front of mailbox as shown on the VDOT standard
RFD-1.
• Private entrances will be installed in accordance with VDOT standard CG-9D. This is the
developer's responsibility.
• Any entrances constructed from the referenced street(s) shall meet VDOT minimum
standards. This is the developer's responsibility.
• Any signs to be installed will be in accordance with the Manual on Uniform Traffic Control
3/8/2007
w's Edge Collector Road, Route 1012, Frederick County Page 2 of 2
Devices and the approved plans.
. I suggest any utilities and/or storm sewer placed within the proposed right-of-way be
backfilled completely with C.R. Type I 21-B Stone. This will greatly reduce the possibility
of any pavement settlement.
. A copy of any/all recorded plats of dedication for drainage easements or additional right-
of-way required for implementation of this proposed project should be provided to VDOT
prior to issuance of any land use permit. Dedication should be made to the
Commonwealth of Virginia.
. A. copy of any/all RECORDED PLATS of dedication to public use (the County of
Frederick) for drainage easements or additional right-of-way required for implementation
of this proposed project should be provided for VDOT review prior to issuance of any
land use permit.
If there are any questions, do not hesitate to contact me at 540-984-5611, or Mr. Stephen
Baluch of our Winchester Office at 540-535-1829.
<<Plan Approval Attachments.pdf>>
Lloyd A. Ingram
Transportation Engineer
VDOT — Edinburg Residency
Land Development
14031 Old Valley Pike
Edinburg, VA 22824
(540) 984-5611
(540) 984-5607 (fax)
3/8/2007
Frederick County, Virginia
Mail to:
Town of Stephens City
Attn: Town Manager
P.O. Box 250
Stephens City, VA 22655
(540) 869-3087
Site Plan Application
Request For Site Plan Comments
Town of Stephens City
Hand deliver to:
1033 Locust Street
Stephens City Town Hall
Stephens City, VA
(540) 869-3087
Please fill out the information as accurately as possible in order to assist the agency with their
review. Please attach one (1) copy of the site plan with this sheet.
Applicant's Name: Urban Engineering & Associates
Address: 600 Pegasus Court Suite 101
Winchester VA 2.2602
Phone Number: (540) 450-0211
Name of development and/or description of the request: Meadows Edge - Collector Road Plan
Construction of Collector Road from Town Run Lane (Rte. 1012) into proposed Meadows Edge residential site.
Location of property: East side of Town Run Lane (Rte. 1012), approx. 0.4 miles south of Fairfax Pike (Rte.
2M intersection.
r
Town of 'Stephens City, use only
Date received Date revision received Date approved
Incomplete Incomplete
Date reviewed Date reviewed
Signature and Date
Signature and Date (revision)
FCSA - JOB# 05-018
Fw.,71 _
, 1 j1; 1, PRINT TICKET# 2333
U 'ring & Associates, Inc.
�non
210 FRONT ROYAL P1 Tel: (540) 450-0211
1-nd " ; _T
L Ll L_ Fax- (540) 450-0210
WINCHESTER, VA 22 0
I rli,]
J. EDGER SEARS. JR., PE.. C.L.S., R.L.A.
Principal
BARRY B. SMITH, PE.
Principal
ERIC S. SIEGEL, PE.
Principal
TO: Frederick County Sanitation Authori
315 Tasker Road
Stephens Citv, VA 22655
ATTENTION: John Whitacre
10 ORIGINALS
0 SPECIFICATIONS
0 COLOR PRINTS
DAVID TWELRANEY. P.E. PRILIAP A. BLEVINS. L.S.
Principal' Associate
JEFFREY. GILIALAND, PE. DAVID E. LELLOCK. PE., L.S.
Principal Aussociate
BRIAN A. SEARS. PE. RYAN G. DAVID. P.E.
Associate Associate
DATE: June 2, 2006
RE: Meadows Edge
Collector Road Plan
TRANSMITTED HEREWITH:
0 PHOTOCOPIES [I CD
[I COMPUTATIONS 0 INVOICE
0 SITE NOTICES 0 OTHER
BLACKLINE PRINTS
❑ MYLAR PRINTS
QUANTITY DRAWING NO. DATE --,DESCRIPTION
- 2 5/31/2006 Construction Plans & Profiles - 3Fd Submission
1 5/31/2006 Comment/Response Letter
OIC
114 � -'Ljfoq
sx-
/C
FOR: 9 APPROVAL 0 RESUBM�ISSION ❑ COMMENTS
[I FIELD USE [I YOUR FILES
SENT BY: [] FIRST CLASS MAIL OUR MESSENGER [] PICKUP
PLEASE: []RETURN
COMMENTS:
[I SUBMIT
[I OTHER
[I COURIER
[-] OTHER
RECEIVED BY: SEN I BY:
[I OVERNIGHT
COUNTY of FREDERICK
Department of Public Works
540/665-5643
FAX: 540/ 678-0682
January 16, 2007
Ms. Natasha Schmidt
Urban, Ltd.
210 Front Royal Pike
Winchester, Virginia 22602
RE: Site Plan Comments - Meadows Edge Collector Road Plan
Frederick County, Virginia
Dear Natasha:
Upon review of the revised site plan received November 9, 2006, all of our previous
comments have been addressed. Therefore, we recommend our approval of the subject site plan.
On January 11, 2007, Ron Stouffer of the Corps of Engineers and I discussed the subject
project. At that time, he indicated that a permit will be required for the proposed stream crossing
reflected on the site plan. Modifications to existing crossings still require a permit. If the proposed
crossing is not included in the general permit, a separate permit will be required.
Please provide our office with the final revision of the Floodplain Alteration associated
with this project.
Sincerely,
�J
foe C. Wilder
Deputy Director
JCW/mlr
cc: Planning and Development
file
CADocuments and Settings\MMMy Documents\Review Formats\meadowedgerev2.wpd
107 North Kent Street • Winchester, Virginia 22601-5000
1
T
VARTAf
Federal Emergency Management Agency
0 Washington, D.C. 20472
N D StiGJ
JAN 16 2007
CERTIFIED MAIL IN REPLY REFER TO:
RETURN RECEIPT REQUESTED Case No.: 07-03-0147R
The Honorable Richard C. Shickle
Chairman At -Large
Frederick County Board of Supervisors
292 Green Spring Road
Winchester, VA 22603
Dear Mr. Shickle:
Community: Frederick County, VA
Community No.: 510063
104
This -responds to a. request that -the -Department -of Homeland security's Federal.Emergency Management
Agency (FEMA) comment on the effects that a proposed project would have on the effective Flood
Insurance Rate Map (FIRM) and Flood Insurance Study (FIS) report for your community, in accordance
with Part 65 of the National Flood Insurance Program (NFIP) regulations. In a letter dated November 9,
2006, Mr. David E. Lellock, P.E., Urban Ltd., requested that FEMA evaluate the effects that the proposed
Meadows Edge project would -have on the flood hazard information shown on the effective FIRM and FIS
report. The proposed project will consist of construction of Collector Road and placement of a triple box
culvert along Stephens Run and Tributary 1 to Stephens Run (Tributary 1). The proposed area of revision
will extend along Stephens Run from approximately 3,450 feet downstream to approximately 400 feet
downstream of Interstate Highway 81 (I-81) and along Tributary 1 from the confluence with Stephens Run
to approximately 850 feet upstream.
All data required to complete our review of this request for a Conditional Letter of Map Revision
(CLOMR) were submitted with letters from Ms. Natasha H. Schmidt, P.E., also with Urban Ltd., and
Mr. Lellock.
We reviewed the submitted data and the data used to prepare the effective FIRM for your community and
determined that the proposed project meets the minimum floodplain management criteria of the NFIP. The
submitted existing conditions HEC-RAS hydraulic computer model, dated November 6, 2006, based on
detailed hydrologic and updated topographic information, was used as the base conditions model in our
review of the proposed conditions model for this CLOMR request. We believe that, if the proposed
project is constructed as shown on the submitted plan entitled "Meadows Edge Collector Road Plan,"
prepared by Urban Engineering and Associates Inc., dated November 6, 2006, and the data listed below
are received, the floodplain boundaries of the flood having a 1-percent chance of being equaled or
exceeded in any given year (base flood) will be delineated as shown on the topographic work map entitled
"Floodplain Study/Alterations — Stephens Run," part of the "Meadows Edge Collector Road Plan," and a
revision to the FIRM would be warranted.
Stephens Run
The effective Special Flood Hazard Area (SFHA), the area that would inundated by the base flood, for the
proposed area of revision along Stephens Run is designated Zone A, with no Base Flood Elevations
(BFEs) determined. The existing conditions model established base flood water -surface elevations
` 2
(WSELs) along Stephens Run from approximately 3,450 feet downstream to approximately 400 feet
downstream of I-81.
As a result of the proposed project, the base flood WSELs will increase and decrease throughout the
proposed area of revision compared to the existing conditions base flood WSELs for Stephens Run. The
maximum increase in base flood WSEL, 0.7 foot, will occur approximately 780 feet downstream of 1-8 1.
The maximum decrease in base flood WSEL, 1.3 feet, will occur approximately 600 feet downstream of
1-81.
As a result of the proposed project, updated topographic and hydrologic information, and updated
hydraulic modeling, the width of the SFHA will increase in some areas and decrease in other areas
compared to the effective SFHA width along Stephens Run. The maximum increase in SFHA width,
approximately _100_ feet, will. occur. approximately 450 feet downstream of I-81. The maximum decrease in
SFHA width, approximately 260 feet, will occur approximately 1,080 feet downstream of 1-8 1.
Tributary 1 to Stephens Run
The-effective-SFHA-for--the-proposed area -of revision-along-Tributary--1-is designated Zone A, -with -no... .
BFEs determined. The existing conditions model established base flood WSELs along Tributary 1 from
the confluence with Stephens Run to approximately 850 feet upstream.
As a result of the proposed project, the base flood WSELs will increase throughout the proposed area of
revision compared to the existing conditions base flood WSELs for Tributary 1. The maximum increase in
base flood WSEL, 0.5 foot, will occur approximately 170 feet upstream of the confluence with Stephens
Run.
As a result of the proposed project, updated topographic and hydrologic information, and updated
hydraulic modeling, the width of the SFHA will increase in some areas and decrease in other areas
compared to the effective SFHA width along Tributary 1. The maximum increase in SFHA width,
approximately 90 feet, will occur approximately 760 feet upstream of the confluence with Stephens Run.
The maximum decrease in SFHA width, approximately 250 feet, will occur approximately 170 feet
upstream of the confluence with Stephens Run.
Upon completion of the project, your community may submit the data listed below and request that we
make a final determination on revising the effective FIRM and FIS report.
• Detailed application and certification forms, which were used in processing this request, must be
used for requesting final revisions to the maps. Therefore, when the map revision request for the
area covered by this letter is submitted, Form 1, entitled "Overview & Concurrence Form," must
be included. (A copy of this form is enclosed.)
• The detailed application and certification forms listed below may be required if as -built conditions
differ from the preliminary plans. If required, please submit new forms (copies of which are
enclosed) or annotated copies of the previously submitted forms showing the revised information.
Form 2, entitled "Riverine Hydrology & Hydraulics Form"
Form 3, entitled "Riverine Structures Form"
3
• Effective October 30, 2005, FEMA revised the fee schedule for reviewing and processing requests
for conditional and final modifications to published flood information and maps. In accordance
with this schedule, the current fee for this map revision request is $4,000 and must be received
before we can begin processing the request. Please note, however, that the fee schedule is subject
to change, and requesters are required to submit the fee in effect at the time of the submittal.
Payment of this fee shall be made in the form of a check or money order, made payable in U.S.
funds to the National Flood Insurance Program, or by credit card. The payment must be forwarded
to the following address:
Federal Emergency Management Agency
Fee -Charge System Administrator
P.O. Box 22787
- - --- - Alexandria, -VA 22304-
• As -built plans, certified by a registered professional engineer, of all proposed project elements
_ • Community acknowledgment of the map revision request _
• Hydraulic analyses, for as -built conditions, of the base flood if they differ from the proposed
conditions models
After receiving appropriate documentation to show that the project has been completed, FEMA will initiate
a revision to the FIRM and FIS report. Because BFEs may be established as a result of the project, a
90-day appeal period would be initiated, during which community officials and interested persons may
appeal the BFEs based on scientific or technical data.
ne basis of this CLOMR is, in whole or in part, a channel-modification/culvert project. NFIP regulations,
as cited in Paragraph 60.3(b)(7), require that communities assure that the flood -carrying capacity within
the altered or relocated portion of any watercourse is maintained. This provision is incorporated into your
community's existing floodplain management regulations. Consequently, the ultimate responsibility for
maintenance .of the modified. channel and -culvert rests with. your -community .......... . .... . . ... ... ....... ... _
This CLOMR is based on minimum floodplain management criteria established under the NFIP. Your
community is responsible for approving all floodplain development and for ensuring all necessary permits
required by Federal or State law have been received. State, county, and community officials, based on
knowledge of local -conditions and in the interest of -safety, may set higher -standards -for construction in the
SFHA. If the State, county, or community has adopted more restrictive or comprehensive floodplain
management criteria, these criteria take precedence over the minimum NFIP criteria.
If you have any questions regarding floodplain management regulations for your community or the NFIP in
general, please contact the Consultation Coordination Officer (CCO) for your community. Information on
the CCO for your community may be obtained by calling the Director, Federal Insurance and Mitigation
. A
4
Division of FEMA in Philadelphia, Pennsylvania, at (215) 931-5512. If you have any questions regarding
this CLOMR,-please call our Map Assistance Center, toll free, at 1-877-FEMA MAP (1-877-336-2627).
Sincerely,
Kevin C. Long, CFM, Project Engineer
Engineering Management Section
Mitigation Division
cc: Mr. Mark Cheron
Subdivision and Zoning Administrator
Frederick County
Ms. Natasha H. Schmidt, P.E.
Urban Ltd.
Mr. Bryan Condie
Centex Homes — DC Metro Division
For: William R. Blanton Jr., CFM, Chief
Engineering Management Section
Mitigation Division
I. 1
COMMONWEALTH of VIRCjINIA
DEPARTMENT OF ENVIRONMENTAL QUALITY
VALLEY REGIONAL OFFICE
L. Preston Bryant, Jr. 4411 Early Road, P.O. Box 3000, Harrisonburg, Virginia 22801 David K. Paylor
Secretary of Natural Resources (540) 574-7800 Fax (540) 574-7878 Director
www.deq.virginia.gov
Amy Thatcher Owens
Regional Director
March 8, 2007
Ted Lewis
GeoConcepts Engineering, Inc.
19955 Highland Vista Drive, Suite 170
Ashburn, VA 20147
Re: Town of Stephens City Wastewater Lagoon Closure
Dear Mr. Lewis
We have reviewed the closure report for the Town of Stephens City wastewater lagoon. Based
on the closure report-, the -closure appears to be adequate in that it was completed in accordance with the -
approved lagoon closuue plan dated September 9, 2002. We have no concerns with the information
provided regarding the lagoon closure. If you have any questions regarding this notification, please
contact me at (540) 574-7892 or via e-mail at bdkiracofe@deq.virginia.gov.
deq.virginia.gov.
Sincerely,
Brandon D. Kiracofe
Environmental Engineer Senior
cc: File