HomeMy WebLinkAbout010-85 Red Star Express Lines - Stonewall District - Backfile'a
COUNTY of FREDERICK
IDepartment of Planning and Development
John T.P. Horne - Planning Director
Stephen M. Gyurisin - Deputy Director
703/662-4532
June 12, 1985
Mr. James Wilson
Shenandoah Sand and Gravel
P. 0. Box 2528
Winchester, Virginia 22601
Dear Mr. Wilson:
This letter is to confirm the Frederick County Planning Commission's action at
their meeting of June 5, 1985:
Approval of Site Plan #010-85 of Red Star Express Lines/James Wilson for a 9,787
square foot truck terminal and maintenance/office building with required site
improvements on McGhee Road, Stonewall Industrial Park, in the Stonewall
Magisterial District.
If you have any questions regarding your site plan, please don't hesitate to call
me.
Si rely,
o n T. P. Horne
rector
JTPH/dkg
9 Court Square - P.O. Box 601 - Winchester, Virginia - 22601
It
SITE PLAN #010-85
Red Star Express Lines/James Wilson
Zoned M-1 (Light Industrial)
LOCATION: McGhee Drive, Stonewall Industrial Park
MAGISTERIAL DISTRICT: Stonewall
ADJACENT LAND USE AND ZONING: Open space and industrial land use and M-1 zoning
PROPOSED USE AND IMPROVEMENTS: Construct a 9,787 square foot truck terminal and
maintenance/office building with required site improvements.
REVIEW EVALUATIONS:
Inspections Department - Proposed structures to be built in accordance with
the current edition of the Virginia Uniform Statewide Building Code.
Highway Department - Everything appears satisfactory with the exception that
the applicant show the curbing on the east side extended beyond the property
line. It should be stopped at the property line to be within our minimum
requirements.
Clearbrook Fire Company - No comment.
Sanitation Department - Satisfactory.
Planning and Zoning - The site plan has been amended from the plan presented
on May 22 to include: an on -site detention facility which restricts outflow
to predevelopment rates; an amended maintenance/office building design which
will now also house offices for Mr. Wilson!s refuse business. THis office
use will be for only one full-time office employee. Should Mr. Wilson's use
expand or change at this site, the plan may need to be amended to include
required paved access and parking areas.
STAFF RECOMMENDATIONS: Approval
14
43
t �
M-
a
x� C2.
p RIP
53
IRP M�
4 r°
CITY OF
W,NCHESTER CITY OF P
^ / �•�/ ; WJNCHFSTER »® /
pr
•
•
COUNTY of FREDERICK
Irn pPRtt'v �Q Department of Planning and Development
G``�NN�NG w John T.P. Horne - Planning Director
�� 04 P�FQt�EN� p M E M O R A N D U M Stephen M. Gyurisin - Deputy Director
OEP �EVE�� (P) 703/662-4532
VA Dept. of Hig' t'Transportation �/ , ATTN: Mr. William H. Bushman
Sanitation
Authority
, ATTN:
Mr.
Wellington Jones
Clearbrook
Fire Company
, ATTN:
Mr.
Ralph Robinson
Inspections Department , ATTN: Mr. John W. Dennison
Planning Department , ATTN: Mr. John T. P. Horne
Zoning Department , ATTN: Mr. Stephen M. Gyurisin
FROM: John T. P.
Horne, Director
DATE:
April 19, 1985
SUBJECT: Review
Comments On:
Conditional
Use Permit Subdivision
Vacation of Plat X Site Plan
We are reviewing the enclosed request by Red Star Express Lines
or their representative, Jim Wilson 667-1660
Will you please review the attached and return your comments to me as soon as
possible.
-------------------------------------------------------------- -----------------
THIS SPACE SHOULD BE USED FOR REVIEW COMMENTS: F
EVERYTHING APPEARS SATISFACTORY WITH THE EXCEPTION THEY -SHQ'W
THE CURBING ON EAST SIDE EXTENDED BEYOND THE/PROPERA-WNE.
IT SHOULD BE STOPPED AT THE PROPERTY LINE TO BE WITHIN OUR
MINIMUM REQUIREMENTS. '
Signature , Date /
9 Court Sauare - P.O. Box 601 - Winchester, Virginia - 22601
COUNTY of FREDERICK
Department of Planning and Development
John T.P. Horne - Planning Director
M E M O R A N D U M Stephen M. Gyurisin - Deputy Director
703/662-4532
VA Dept. of Highways & Transportation , ATTN: Mr. William H. Bushman
Sanitation Authority ATTN: Mr. Wellington Jones
Clearbrook Fire Company
, ATTN:
Mr.
Ralph Robinson
Inspections Department
V ATTN:
Mr.
John W. Dennison
Planning Department
, ATTN:
Mr.
John T. P. Horne
Zoning Department
, ATTN:
Mr.
Stephen M. Gyurisin
FROM: John T. P. Horne, Director DATE: April 19, 1985
SUBJECT: Review Comments On: Conditional Use Permit Subdivision
Vacation of Plat X Site Plan
We are reviewing the enclosed request by Red Star Express Lines
or their representative, Jim Wilson 667-1660
Will you please review the attached and return your comments to me as soon as
possible.
THIS SPACE SHOULD BE USED FOR REVIEW COMMENTS:
Signature 0 - Date
9 Court Square - P.O. Box 601 - Winchester, Virginia - 22601
0
COUNTY of FREDERICK
IN Department of Planning and Development
John T.P. Horne - Planning Director
M E M 0 R A N D U M Stephen M. Gyurisin - Deputy Director
-� 703/662-4532
VA Dept. of Highways & Transportation ATTN: Mr. William H. Bushman
Sanitation Authority
�� , ATTN:
Mr.
Wellington Jones
Clearbrook Fire Company
, ATTN:
Mr.
Ralph Robinson
Inspections Department
, ATTN:
Mr.
John W. Dennison
Planning Department
, ATTN:
Mr.
John T. P. Horne
Zoning Department
, ATTN:
Mr.
Stephen M. Gyurisin
FROM: John T. P. Horne, Director
DATE:
April 19, 1985
SUBJECT: Review Comments On:
Conditional
Use
Permit Subdivision
Vacation of Plat X Site Plan
We are reviewing the enclosed request by Red Star Express Lines
or their representative, Jim Wilson 667-1660
Will you please review the attached and return your comments to me as soon as
possible.
----------------------------------------------------------------------------------
THIS SPACE SHOULD BE USED FOR REVIEW COMMENTS:
Central water and sewer services are available to the proposed
subdivided property.
Signature Date
9 Court Saitare - P.O. Box 601 - Winchester, Virginia - 22601
COUNTY of FREDERICK
IDepartment of Planning and Development
John T.P. Horne - Planning Director
Stephen M. Gyurisin - Deputy Director
703/662-4532
M E M O R A N D U M
TO: Frederick County Planning Commission
FROM: John T. P. Horne, Director
SUBJECT: Red Star Express Site Plan
DATE: May 10, 1985
At the time of preparation of this agenda, the staff has not received
the additional information requested by the Commission in reference
to the stormwater management on the Red Star Express Site Plan. It
is uncertain whether this information will be available at the
meeting on May 15. The staff would recommend that this item be
tabled pending receipt of this information. If you have any
questions, please don't hesitate to contact me.
JTPH/rsa
9 Court Square - P.O. Box 601 - Winchester, Virginia - 22601
0
STORMWATER MANAGEMENT PLAN
RED STAR EXPRESS
May 9, 1985
Site Area (A) = 6.324 Acres
tc = 8 min. post development
15 min. pre development
a = 117.7
b = 19.1
c = 0.2 pre development
0.6 post development
Predeveloped Runoff (qo)
a 117.7
i = b+tc = 19.1+15 =3.45
Allowable Runoff (qo) = cia = 0.2 X 3.45 X 6.3 = 4.35 cfs
Postdevelopment Runoff (Q)
a 117.7
i = . b+tc = 19.1+8 = 4.34
Qo = cia = 0.6 X 4.34 X 6.3 = 16.4 cfs
Critical Storm Duration (Tc)
tc
2cAa (b-La.)
Tc qo -- b
6.3 X 117.7 X 17.1
Tc = 4.35 -19.1
Tc = 59.1 - 19.1 = 40
Peak Inflow (Qo)
117.7
i = 19.1 +40 = 2.0
Q0=ciA=o.6'X2x6.3 =7.56
Required Storage Volume (V) `
EQQo tc qo Tc 3 o To Tc + 4 ` z T - 60
7.56X8 4.35X40 3 x4.35X8
V = 7.56 X 40 + 4 2 - 4 ] 6o
V = [302.4+15.1-87-26.1] 60
of
0
V = 12,264 Cu. Ft.
Storage Provided = 300 X 3.5 X 15 = 15,750 cu. ft.
Permitted Discharge = 4-35 cfs
= 15" cmp @1- W�
0
STORMWATER MANAGEMENT PLAN
RID STAR EXPRESS
May 9, 1985
Site Area (A) = 6.324 Acres
tc = S min. post development
15 min. - pre development
a = 117.7
b = 19.1
c = 0.2 pre development
0.6 post development
Predeveloped Runoff (qo)
a 117.7
i = b+tc = 19.1+15 = 3.45
Allowable Runoff (qo) = cia = 0.2 X 3.45 X 6.3 = 4.35 cfs
Postdevelopment Runoff (Q)
a 117.7
i =.b+tc = 19.1+8 = 4.34
Qo = cia = 0.6 X 4.34 X 6.3 = 16.4 cfs
Critical Storm Duration (Tc)
tc
2 c A a (b- 4)
Tc qo b
2 X o.6.x 6.3 X 117.7 X 17.1
Tc= 4.35 -19.1
Tc = 59.1 - 19.1 = 40
Peak Inflow (Qo)
117.7
i = 19.1 + 40 = 2.0
Qo=ciA=o.6X2X6.3 =7.56
Required Storage Volume (V)
Qotc goTc 3 goTc
V = E
0 Tc + 4 - 2 4 1 60
7.56X8 4.35X40 3 X4.35X8
V= [-56 X 4o + 4 2 4 6o
V = [302.4 + 15.1 - 87 - 26.11 60
C
ql
V = 12,264 Cu. Ft.
Storage Provided = 300 X 3.5 X 15 = 15,750 cu. ft.
Permitted Discharge = 4-35 cfs
= 15" cmp @1.9-