This application is not complete if the following are not included:
-VWsk 3 1. One set of comment sheets from the following agencies along with any marked
copies of the plan;
1 U L VDOT City of Winchester
✓f Sanitation Authority Town of Stephens City
Inspections Dept. Town of Middletown
✓ Fire Marshal Health Dept.
County Engineer Parks & Recreation
`f Airport Authority Soil & Water Conservation Dist.
IA 2. One copy of the Site Plan application.
3. Five copies of the Site Plan.
4. One reproducible copy of the Site Plan (if required).
5. One 35mm. slide of the Site Plan (if required).
TRACKING
Date
Application received.
99 All necessary agency comments received.
3 Fee Paid (amount $
Site Plan to Planning Commission via bi-monthly.
Site Plan heard by Planning Commission (if required).
t/ Revisions received (if required).
! C& 3 Date of approval.
3 Info added to ro[GZCC. L4 t3as e.
COUNTY OF FREDERICK, VIRWIA •
DEPARTMENT OF INSPECTIONS
Caller LARR�! UUI3ECk� Time Called { PM ) Date Called 8 ` yc:
Phone No. Q-7- 770o Time Requested 65A-P Date Requested A501rP
Received By &A,3 A . Y#rr7 Date of Inspection 8 /', h+
PERMIT HOLDER NAME 5"Cl<Lly OMPA#J
RT. NO. Lot No. SEC. No. SUBDIVISION
STREET NAME 2-66 AKsor- 00,) _=
DIRECTIONS MILL -WOOD RKE -M / V�Gnv�y BUILDING NO.
�T 7Z�i 7UKrJ (� �rJ� PLUMBING NO.
�Ki3GR l'_J�1,2T 5 rr� A►.l �( _� ELECTRICAL NO.
P�%5T CzLA,Z_E 6 MECHANICAL NO.
SIGN NO
DISTRICT 1 5144WN
PERMIT FOR: B1_IIr RIocr' INDuSrfLi (�,610E'ttouSC A001-noi
Type of Inspection
Residential
Footers
Slab
Water
Sewer
Rough Plumbing
Groundworks
Other:
Setbacks: FR
Draintile
Service
Rough Electric
Rough Mechanical
Gas Piping/Test
Commercial
BK
L
R
Gas Fire -up Final Electrical
Framing Final Mechanical
Final v� Site Plan
Final Building Fire Marshall
Final Plumbing Special/Complaint
Time In: 10 * 3Z Temperature k 801,F Cut in No,
Time Out: Weather SuPJ'J Y
Results: Approved
Comments: 5
Rejected
V t
a
Signature �.1X��n a Date 81"/`a',
SITE PLAN APPLICATION
Complete the following application:
DATE APPLICATION
1. Development kda5jT/�3 /i-x
2. Location of Property: lfli�l Idne InWds r,Ql park
(by street name)
3. Property Owner:
Address: I��•vx l�4f 7
7--l9e,5 7
Telephone: 70•5 - 39ov
4. Applicant/Agent:
Address:
Telephone:
5 . Designer: 4/. W.
Address: o W
Aie-hzslr/
Telephone: lCn i -
Contact:
6. Is this an original or revised Site Plan?
Original Revised
-5-
•
0
7. Total area of parcel to be developed: M,�" 33 (Ic,,a-S
8. Property Information:
a) Property ID #: &V_ 4 go 9
b) Current Zoning: M_
c) Present Use:
d) Proposed Use:
e) Adjoining Property Zoning: M%
f.)..Adj-oining -Property Use: Indoo, 'L_L b u`�/�I&I-;IR/.j,lY-e/
g) Magisterial District: '91V
I have read the material included in this package and understand
what is required by the Frederick County Planning Department. I
also understand that all required material will be complete prior
to the submission of my site plan.
Signature:
Date: �( lZ 1ci's
--o ge 5 0 b)-M 40—
COUNTY OF FREDERICK' VIRGINIA
W �
o FIRE AND RESCUE DEPARTMENT
FARE RESCUE 9 N. Loudoun Street, 2nd Floor
VIRGINIA Winchester, Virginia 22601
Thomas W. Owens
Director
ME-M0RANDUM
TO: John Trenary, Building Official
FROM: Douglas A. Itiiracofe, Fire Marshal
SUBJECT: -Blue Ridge Industries
DATE: Juiy 15, 199:
Douglas A. Kiracofe
Fire Marshal
i have illspucl.ed Blue Ridge Industl'it s ' Addition for a
Temporary Occupancy Permit.. I : ave found all fire protection
systems to be complete ar.d in serv_ce at this time.
The following i�-ems are and muss. be chec :ed
prier to issuance of a Permanent. Certificate of Occupancy.
i Post street address numbers C:': :uilding and at entrance from
Victory Lane .
2. Columns where hose stati.;ns .are located have been painted
red but must be labeled "Fire hose. "
3. Fire lane:_ on exterior must- 'L)e completed.
4. Spare sprinklers must be placed in sprinkler cabinet .at
riser.
A rest of the roil down fire door is scheduled this date.
IL it passes, r_-he above four items w_1i be the only items I have
outstanding on this project.
DAK -ilc:
cc: Evan Wvatt-, Planning Dept.
Eddie keeier, Chief Co. 18
File
DIRECTOR - (703) 665-5618 FIRE MARSHAL - (703) 665-6350 FAX - (703) 678-0682
BLU I RIDGE I4DUSTKIES, INC,
P 1 winchester. Virginia 22604 (703) 662-39lxl
Fax (703) hb_' 3010
�1r. I:anny ('. 1?'11.:1
Pl arirrcr 1
(,hurl t.,r• of F l^ederi c jk
1)c'1m tment of P I annonr.; anc:l Dovcl opemen I.
11.0. Box 601
Winchester, ``'i r•t~ i ni.`, -'2604
Dear Lanny:
Etc t;Z.r c� i nt; Li,mhc�r ar t,r,rrnl t , ri:S we ri i m.-ussed curl I h" I,Iiom. •
.At. i I 1 Shoppi rw Ar'uUrtcl for r-ont.rac tors.
cluo Les rs c;oIII t.rac, t.or w i l t be acIcc:tcd immr.d i n I. i�
r)nr'king lot. wl I I be j.)t9VE`(f wit11 a Illlnimulll „i pr'ill„` ;wd do tll,ie 41.•Fri
its per site l)l.xr) wi I.hin 60 daps.
1 hank you once aga 1 ri .
i COUNTY of FREDERICK
Department of Planning and Development
703 / 665-5651
Fax 703 / 678-0682
April 9, 1993
Mr. Ron Mislowsky, P.E.
G.W. Clifford and Associates
200 North Cameron Street
Winchester, Va 22601
Dear Ron:
This letter is to inform you that the Frederick County Department of Planning and Development
administratively approved Site Plan #009-93, of Blue Ridge Industries, on April 9, 1993.
This plan is a revision to Site Plan #017-91 and calls for the construction of a 47,000 square foot
addition to the existing industrial site, 73 parking spaces and 4 handicapped spaces that are to be a
minimum of bituminous prime and double seal, two loading bays, and approved calculations
regarding increased runoff.
Please call regarding any questions you have about this letter.
Sincerely,
Lanny Bise, II
Planner I
cc: Harrington Smith, Shawnee District Supervisor
Gus Nusu, General Manager, Blue Ridge Industries
LCB/gll
1) North LoU(loun Strcct P.O. Box 601
Winchester, VA 22601 Winchester, VA 22604
i COUNTY of FREDERICK
Department of Planning and Development
703 / 665-5651
Fax 703 / 678-0682
March 31, 1993
Mr. Ron Mislowsky, P.E.
G.W. Clifford and Associates
200 North Cameron Street
Winchester, Va 22601
Dear Ron:
This letter is in reference to my review of site plan 9009-93 of Blue Ridge Industries. The overall
concept of this plan is fine; however, there are a few issues that need to be addressed. I offer the
following comments:
1) Based on discussions with Plant Management, this department decided that 100 employees
would be the maximum at the facility at any one time. Therefore, the parking requirement
will be 75 spaces (75% of 100 spaces).
2) With a parking requirement of 75 spaces, the handicap space requirement is four. One
additional is needed.
3) /Aased on careful consideration, your request to hold off laying down a prime and
double seal surface until the adjoining road is improved is denied. A prime and double seal
surface must be provided prior to the issuance of any occupancy permits.
4) I am still waiting on approval from Ed Strawsnyder, County Engineer.
This site plan is scheduled to appear on the April 7, 1993 Planning Commission Bi-Monthly report.
We should receive administrative approval authority at that meeting. I look forward to your
resubmission.
Please call with any questions.
Sincerely,
Lanny Bise,
Planner I
O North Loudoun Str-cct P.O. Box 601
Winchester, VA 22601 Winclicster, VA 22604
gilbert w. cli f f ord & associates, inc.
200 North Cameron Street • Winchester, Virginia 22601
703-667-2139 9 Fax: 703-665-0493
March 12, 1993
Mr. Lanny Bise
Frederick County Planning Department
P.O. Box 601
Winchester, Virginia 22601
Re: Blue Ridge Industries
Dear Lanny,
I want to thank you for your preliminary comments on the Blue Ridge
Industries expansion plans. Items 1, 2 and 3 have been addressed on the plans
enclosed here with the application. These plans have also been revised per the
Review Agency comments.
Concerning the number of employees, 1 believe Mr. Nusu meant 100 total
employees. Blue Ridge Industries runs three shifts. The 40 employees existing
and an additional 40 with the expansion is a conservative estimate of a one shift
total.
If during your review, you should have any comments, please do not
hesitate to call.
Regards,
on Mislowsky, P.E.
RAM/kf
cc: Mr. Larry Dubyk
•
gilbert w. cli f ford & associates, inc.
200 North Cameron Street • Winchester, Virginia 22601
703-667-2139 • Fax: 703-665-0493
memorandum
To: Lanny Bise, II
From: Ron Mislowsky, P.E.
Re: Blue Ridge Industries Site Plan Application
Date: March 12, 1993
A couple of weeks ago, you called me and let me know that Inspections had
somehow given their comment sheet directly to you. You indicated that the
standard comment had been made and that you would hold on to it until you
received the formal application.
The remaining comment sheets are attached.
:7
•
Thomas W. Owens
Director
Mr. Ron Mislowsky
G. W. Clifford & Assoc.
200 N. Cameron Street
Winchester, VA 22601
Mr. Mislowsky,
COUNTY OF FREDERICK, VIRGINIA
FIRE AND RESCUE DEPARTMENT
9 N. Loudoun Street, 2nd Floor
Winchester, Virginia 22601
February 25, 1993
Douglas A. Kiracofe
Fire Marshal
In reviewing the plan for Blue Ridge Industries, I have
found several areas that are still not in compliance with
Frederick County Chapter 10.
1. Chapter 10 Section 2-3-2.2 requires fire lanes to be 20' in
width with the nearest edge 10' away from the structure. With
only 26.01' to the property line there is insufficient room to
meet the requirements for fire lanes.
2. In the TRC Meeting, I requested the Siamese connection be on
the same side of the fire lane as the hydrant used to supply the
Siamese. This was not changed on the submitted plan.
3. As plans progress for this project I want to be certain that
the sprinkler system in the expansion will be tied into the
existing fire dept. connection. Dual siamese connections on one
building is an unsafe practice and should always be avoided.
In closing, there are several items on this site that are
inconsistent with nationally recognized standards regarding fire
safety design. Additionally, issues with the Building Official
and this office will have to be addressed before I can approve
this site plan.
Thank you.
DAK:ilc
cc: File
S i j y
Douglas A. Kiracofe
Fire Marshal
DIRECTOR - (703) 665-5618
FIRE MARSHAL - (703) 665-6350
FAX - (703) 678-0682
��
jNTY OF FREDERICK, VIRGIN���
�
FIRE MARSHAL'S OFFICE
LAND DEVELOPMENT COMMENTS
~
^
`
Control
No. 020993134
Date
Received 020993 Date Reviewed 022593
Applicant
Name
�
G. W.
Clifford
_______' _____--
& Assoc.
Address
200 N'
Cameron
Street
Winchester,
VA 22601
Project
Name
Blue Ridoe
Industries
Phone No. 703-667-2139
Type of
Application
Site Plan Current Zoning M-1
1st Due
Fire Co. 18
1st Due Rescue Co. 18
Election
District Shawnee
-
RECOMMENDATIONS
Automatic
Sprinkler System
X Residential Sprinkler System
Automatic
Fire Alarm
------'-
System
--
X Other
Emergency Vehicle Access;
Adequate Inadequate X
Fire Lanes Reouired: Yes X
Comments: See attached
Not Identified
No
Roadway/Aisleway Widths;
Adequate
Inadequate
X Not
Identified
Special Hazards
Noted;
Yes
X
No
Comments:
While there are
'--'-'---
four
hydrants shown
-'---'---
on the
plan, they are all
basically
located on the west
side
of the project.
This
will require long
hose lays
for any fire occurring
on
the east side
of the
building.
0
Hydrant Locations;
Adequate
Inadequate X
Siamese Connection Location;
Approved X Not Approved
Additional Comments: SEE ATTACHED.
Review Time 2 hrs
Not Identified
Not Identified
PLANS DISAPPROVED
FIRE ~- �IVIARSHAL9 FRE[)ER/CK COUNTY
Douglas A. Kiracofe
Fire Marshal
C�
0
REQUEST FOR SITE PLAN COMMENTS
Frederick County Inspections Department
Attn: Building Official
P.O. Box 601
Winchester, Virginia 22601
(703) 665-5650
The Frederick County Inspections Department is located at 9 North
Loudoun St., 2nd Floor of the Hammon Building in Winchester, if you
prefer to hand deliver this review.
Applicant's name, address and phone number:
n 4 ---7 -. ! If
Name of development and/or description of the request:
1
Location:
16G!&aI
Inspection Department Comments • Building shall comply with the Virginia Uniform
Statewide Building Code and Section 305, Use Group F-1 (Factory & Industrial) of the
BOCA National Building Code/1990. Other codes that apply are title 28 Code of Federal
Regulation, Part 36 Nondiscrimination on the Basis ot Disability by Public Ac5bmmdations
and in Commercial Facilities. Need to show min. 3 H.C. parking spaces for ADA
compliance (Note: Section 36.403 ADA Path ot Travelo e). Ques ion on ZADA Access
between buildings with the floor elevation difference. (NOTE: Table 905.2 Fxterior
wall fireresistance ratings) (Max. permitted with our wall and sprTMier is required).
Code Administrator Signature & Date:
t
(NOTICE TO INSPECTIONS DEPT.*PLEASE RETURN THI
NOTICE TO APPLICANT `''
It is your responsibility to complete this form as accurately as
possible in order to assist the agency with their review. Also,
please attach a copy of your plans and/or application form.
r
-14-
COUNTY of FREDERIJ
Department of Planning and Developm
703,1665-5
REQUEST FOR SITE PLAN COMMENTS FAX 703/667-0
Frederick County Sanitation Authority
P.O. Boa 618, Winchester, Virginia 22601
(703) 665-5690
The Frederick County Sanitation Authority is located on the
second floor of the Old Frederick County Courthouse in
Winchester, if you prefer to hand deliver this review form.
Applicant's name, address and phone number:
gLyr 09-160 � /ilvJo srjrj*,4C(' .,A..
�o. 00ae moo ;pq-<f 61-s00400
uvi,60eo0 W9Y7K4, v0/ 0?j ! e
Name of development and/or description of the request:
�Or �/4OZ&& 0*406' "7 1A�S'
S/odt OD4900 Y AtF V/si040
Location:
_Vic y'�i�y 1w0fo " 14
Sanitation Authority Comments:
WoeI A
foo
Apr! HMV,,
v f, wwze ",A
c'a40�� dA
-------------------
F
Sanit . Signature & Date:
�''�
r
(NOTICE TO SANITATION A E RETURN TH
�0 PLICANT. )
ACYTICE 1'0 APPLICANT
It is your responsibility to cOmplete this for- .a4 accurately as
possible in order to assist the agency wig,, their review. 7''so,
please atC.cu�11 jTwO copies of your n1anG
application form.
Q Cniirt - P n Rnv rni ���inri., �.,
K
0 0
REQUEST P^- ^^ -TAN COMMENTS
Winchester Regional Airport
Attn: Executive Director
Route 1, Box 208-A
Winchester, Virginia 22601
(703) 662-2422
The Winchester Regional Airport is located on Route 645, off of
Route 522 South, if you prefer to hand deliver this review form.
Applicant's name, address and phone number:
Name of development and/or description of the request:
Location:
Winchester Regional Airports Comments:
See comments on back.
Airport Signature and Date: Kenneth V. Wiega�d, Executive Director 02/23/93
(NOTICE TO AIRPORT. * PLEASE RETURN THIS FORM TO APPLICANT.)
NOTICE TO APPLICANT
It is your responsibility to complete this form as accurately as
possible in order to assist the agency with their review. Also,
please attach a copy of your plans and/or application form.
-17-
9?-
0
Please consider the fol' .- of n- ^--n:ments when reviewing this
Request for Master Development Plan:
The Developer should be familiar with and be required to
comply with the provisions of the Frederick County Airport Zoning
District (AP-1) and Airport Support Area (ASA) described in the
Frederick County Comprehensive Policy Plan. The developer should
also be familiar with the provisions and requirements of the
following codes:
Title 15.1 Code of Virginia, Section 489 (Purpose of Zoning
Ordinan<=es) and Section 491.02 (Airport Safety Zoning).
Title 5.1-25.1 Code of Virginia (Permits Required for Erection of
Certain structures.)
As Winchester Regional Airport expands services and
operations, noise associated with such expansion is very likely
to increase. The Airport Support Area established by the
Frederick County Comprehensive Policy Plan is designed to
discourage residential development.in the vicinity of the airport
to preclude citizen concerns for noise created by aircraft
operating on, to and from Winchester Regional Airport.
If the developer is planning residential development
adjacent to the ASA or under a flight path used regularly by
aircraft outside of the ASA as they arrive or_depart the Airport,
he should be either required or encouraged to insulate all
habitable structures for noise and be required to specifically
address, in the property Covenants and Easements, existing
airport related noise and the probability of increased noise as
airport operations expand.
Specific Comments: The proposed structure's site lies under the Airport's
Transition Area which begins a distance of 500' from the Runway Centerline
and extends away from the runway at a ratio of 7:1 to a height of approximately
877 feet (Mean Sea Level) or 150 feet above the airport elevation (727').
The proposed structure must not penetrate the Transition Area. �,
`�
COUNTY OF NREDERICK, VIRGINIA
1A
_ --
P4 W _
�
FIRE AND RESCUE DEPARTMENT
�/� lJ�)/
9 N. Louduun Street, 2nd Floor
Winchester, Virginia ?2601
Thomas W. Owens
Director
February 25, 1993
Mr. Ron Mislowsky
G. W. Clifford & Assoc.
200 N. Cameron Street
Winchester, VA 22601
Mr. Mislowsky,
Douglas A. Kiracofe
Fire Marshal
In reviewing the plan for Blue Ridge Industries, I have
ut�t sevt :t:_ l areas that are st._ ll not in compliance with
Frederick County Chapter 10.
1. Chapter 10 Section 2-3-2.2 requires fire lanes to be 20' in
width with the nearest edge 10' away from the structure. With
only 26.01' to the property line there is insufficient room to
meet the requirements for fire lanes.
2. In the TRC Meeting, I requested the Siamese connection be on
the same side of the fire lane as the hydrant used to supply the
siamese. This was not changed on the submitted plan.
3. As plans progress for this project I want to be certain that
the sprinkler system in the expansion will be tied into the
existing fire dept. connection. Dual siamese connections on one
building is an unsafe practice and should always be avoided.
In closing, there are several items on this site that are
inconsistent with nationally recognized standards regarding fire
safety design. Additionally, issues with the Building Official
and this office will have to be addressed before I can approve
this site plan.
Thank you.
Si e y
Douglas A. Kiracofe
Fire Marshal
DAK:jlc
cc: File
DIRECTOR - (703) 665-5618 FIRE MARSHAL - (703) 665-6350 FAX - (703) 678-0682
No.
�.������������
Applicant Name G' �' C1ifforu & Assoc.
... ����������_������������................. ... .. ..... - ............................. ........ _.........
Address 200 N' Cameron Street
Winchester, VA ��-'
Project Name Blue Ridge Industries
Phone No. 703-667-2139
Type of Application Site Plan Current Zoning M-1
1st Due Fire Co. 18 1st Due Rescue Co. 18
Election District Shawnee
_ ...... ... �...... ........
������������������������������_
Automatic Sprinkler System X Hesidential Sprinklei stem
Automatic Fire Alarm System X Other
Emergency Vehicle Access;
Adequate Inadequate X
Fire Lanes Required; Yes X
Comments: See attached.
Roadwav/Aisleway Width,
Not Identified
No
Adequate Inadequate X Not Identified
___
Special Hazards Noted; Yes X No
Comments: While there are four hydrants shown on the plan, they are all
basically located on the west side of the project. This will require long
hose lays for any fire occurring on the east side of the building.
Hydrant Locations;
Adequate lnadequate X
...............
Siamese Connection Location;
Approved X Not Aooroved
Additional Comments: SEE ATTAr-4Fn
Review Time 2 hrs
Douglas A. Kiracofe
Not Identified
Not Identified
�
���o� PLANS ~~= DISAPPROVED
FIRE =- MARSHAL, FREDER;CK COUNTY
0
0
COUNTY of FREDERICK
Harvey E. Strawsnyder, Jr., P.E.
Director of Engineering &
9 North Loudoun St., 2nd Floor
703/665-5643
March 11, 1993
Mr. Ron Mislowsky
Gilbert W. Clifford and Associates, Inc.
200 North Cameron Street
Winchester, Virginia 22601
RE: Blue Ridge Industries, Inc.
Dear Ron:
We have completed our review of the subject site plan and offer
the following comments:
1) It is suggested that schedule 40 PVC be utilized in lieu of
corrugated PVC for the downspout drain line.
2) Indicate that the existing 15 inch RCP shall be removed
within the building.area.
3) Provide an easement immediately downstream of the 15 inch
and 27 inch RCP outlets to accommodate the placement of the
proposed rip -rap. This easement should take the form of an
agreement between Blue Ridge Industries and the adjacent
land owner considering the rip -rap encroaches on the
adjacent property.
4) Provide cleanouts at appropriate locations along the six
(6) inch drain line (i.e., where the line turns the corner
of the building) .
5) Permanently incorporate drainage calculations on Sheet 3 of
3.
6) The proposed design reflects a modification to a previously
approved site plan which did not include stormwater
detention. Any future site development will require
complete stormwater management assuming that the entire
site is undeveloped.
Fax: 703/678-0682 - P.O. Box 601 - Winchester, Virginia - 22604
j_
0
0
Mr. Ron Mislowsky
Page Two
March 11, 1993
If you should have any questions regarding the above comments,
please do not hesitate to contact us.
HES:rls
cc: Planning and Zoning
file
Sincerely,
Harvey. . Strawsnyder, Jr., P.E.
Director of Public Works
APPLICANT'S CHECKLIST
Your site plan should include the following:
Administrative Information
Y N
- 1. Name of proposed development.
2. Name and address of owner.
3. Name and address of developer.
4. Name, address and phone number of designer.
�✓ 5. Certificate of surveyor, engineer or architect.
_ 6. Date plan prepared and date of revisions.
_IVh_ 7. A listing of all conditions placed on the site as
a result of a conditional use permit or conditional
zoning approval.
8., A space labeled "approved by the Zoning
Administrator" for the approval signature and date of
.approval.
General Site Information
Y
N
9. Location map (scale 1:2000)
10. Magisterial District of site
✓
11. Scale of site plan (not to exceed 1:50)
✓
12. North Arrow
13. Zoning of site
14. Use and zoning of adjoining properties
Lots/Uses/Buildings
and Structures
Y
N
- 15. Surveyed boundaries for all lots and parcels (-c"
16. Acreage of all lots included in the plan
17. The location and dimensions of all required
/
✓
setbacks and yard areas
18. Location of all buildings, structures and uses
19. The proposed use of each building, structure and
area
20. The location and type.of all dwelling units
_V-1,
'T21. Ground floor area and total floor area of; all
.-buildings _ with -:,FAR calculations for ' commercial;.- and
industrial zoning .district
x22.,.The height, of;iall buildings and structurestvq.
N)A
423. The location and dimensions of all signs
-7-
Lots/Uses/Buildings and Structures (con't)
Y N
24.
Location
of outdoor lighting fixtures
25.
Location
and nature of outdoor storage areas
N�
26.
Location
and area of common open space
27.
Location and description of all recreation
facilities
28.
Location
of sidewalks and pedestrian ways
29.
Location
of outdoor trash receptacles
Roads
Y N
N 30. Name and number of existing and planned streets on
and adjoining the site
Al 31. Location of existing and planned streets on and
adjoining the site
32. Dimensions, boundaries width, pavement and
construction of planned roads
33. Location and dimensions of all proposed entrances
from public right-of-ways
Utilities
Y N
Parking
Y , N
34. Location of all utilities, including sewer and
water lines with the size of lines, mains and laterals
35. Location and width of all easements, including
access, utility and drainage easements
36. Location and nature of fire lanes, fire hydrants
and all other facilities necessary to meet the Fire
Code requirements
37. Calculations describing the required number of
parking and loading spaces
38. Location and dimensions of all parking and loading
spaces, driveways, parking aisles, curbing and other
features to be used
39. Location and dimension of all handicapped spaces
•
Natural Features
Y N
/ 40. Existing and finished contour lines
y/P 41. Location of steep slopes, woodlands, floodplains
wetland, sinkholes and other environmental features
i 42. Location of streams and drainage ways
Landscaping
Y N
Nl1l 43. Landscaping plan describing location and types of
plants to be used
�A(� 44. Location of required buffers and screening with
cross -sections -or --profiles. --
Erosion and Sediment Control
Y N
45. A stormwater management plan with run off
calculations and location and description of facilities
to be used -
46. Soil erosion and sedimentation control plan with
location, types and examples of provisions to be used
. I
uH
CIRTY OF FREDERlCK, VIRGINI
A*''
FIRE MARSHAL'S OFFICE
LAND DEVELOPMENT COMMENTS
Control
No. 031293246
Date Received 031293 Date Reviewed 032293
'
Applicant
Name G. W.
Clifford
& Assoc.
Address
200 N.
Cameron
Street
Wincnester, VA
22601
Project
Name BluE
Ridge Industries
Phone No.
703-667-2139
Type of Application
ist Due Fire Co. 18
Election District
Site Plan (Rev) Current Zoning
1st Due Rescue Co. 18
Shawnee
Automatic Sprinkler System
Automatic Fire Alarm System
RECOMMENDATIONS
X Residential Sprinkler System
X Other
M-1
Emergency Vehicle Access5
Adequaze X Inadequate Not Identified
---- ---- ----
Fire Lanes Required; Yes X No
Comments: Posted fire lanes required at all hydrants and along east
and west sides of building as labeled.
Roadway/Aisleway Widths;
Adequate X Inadequate
----
Special Hazards Noted; Yes
_
Comments:
Not Identified
U�
�� ��
�� ��
� ��
Hydrant Locations�
Adequate X .
Inadequate
Not
Identified
Siamese Connection Location;
*pproved X
�ot Approved
` Not
Identified
Additional Comments:
Approve�
for construction.
Review Time .5 hr
COUNTY
Fire Marshal
e
APPLICANT'S CHECKLIST
Your site plan should include the following:
Administrative Information
Y N
_✓ _ 1. Name of proposed development
_ 2. Name and address of owner
3. Name and address of developer
_ 4. Name, address, and phone number of designer
_✓ _ 5. Certificate of surveyor, engineer, or architect
_ 6. Date plan prepared and date of revisions
7. A listing of all conditions placed on the site as a
result of a conditional use permit or conditional
zoning approval
8. A space labeled "approved by the Zoning
Administrator" for the approval signature and date
of approval
General Site Information
i7�Rj
/ ' SD
✓/ _ 9. Location map (scale 1:2000)
10. Magisterial District of site
_ 11. Scale of site plan (not to exceed 1:50)
12. North Arrow
_ _ 13. Zoning of site
14. Use and zoning of adjoining properties
Lots/Uses/Buildings & Structures
Y N
15.
Surveyed boundaries for all lots and parcels F_,s
16.
Acreage of all lots included in the plan a `
_
_
17.
The location and dimensions of all required setbacks
_
and yard areas
18.
Location of all buildings, structures, and uses
_
19.
The proposed use of each building, structure, and
area
�1'ga
20.
The location and type of all dwelling units
_ 21.
Ground floor area and total floor area of all
buildings with FAR calculations for commercial and
industrial zoning districts
22.
The height of all buildings and structures
go- -NJA 23. The location and dimension of all signs
7
n
Lots/Uses/Buildings & Structures (con't)
Y N
24.
Location
of
outdoor lighting fixtures
_
25.
Location
and
nature of outdoor storage areas
26.
Location
and
area of common open space
27.
Location
and
description of all recreation facilities
�o- N1Q
28.
Location
of
sidewalks and pedestrian ways
29.
Location
of
outdoor trash receptacles
Roads
Y N
f_ 30. Name and number of existing and planned streets on
and adjoining the site � J,---Y= m ;'
31. Location of existing and planned streets on and
adjoining the site
32. Dimensions, boundaries, width, pavement, and
construction of planned roads
33. Location and dimensions of all proposed
entrances from public right-of-ways
Utilities
Y N
1� � J__
W�, 'AN a" . e .. - C -
34. Location of all utilities, including sewer
and water
/
lines with the size
of lines, mains, and
laterals
35. Location and width
of all easements,
including
access, utility and
drainage easements
36. Location and nature
of fire lanes, fire
hydrants,
and all other facilities necessary to meet the Fire
Code requirements
I,,, �I,, - r„
Parking
Y N
37. Calculations describing the required number of
parking and loading spaces
38. Location and dimensions of all parking and loading
spaces, driveways, parking aisles, curbing, and
other features to be used
_ 39. Location and dimension of all handicapped spaces
n
A.
I.
0 •
Natural Features
Y N
40. Existing and finished contour lines
41. Location of steep slopes, woodlands, floodplains,
wetlands, sinkholes, and other environmental
features
y� 42. Location of streams and drainage ways
Landscaping
Y N
43. Landscaping plan describing location and types of
plants to be used
Eja 44. Location of required buffers and screening with cross
sections or profiles
Erosion and Sediment Control
Y N
45. A stormwater management plan with run off
calculations and location and description of
facilities to be used
46. Soil erosion and sedimentation control plan with
location, types, and examples of provisions to be
used
I