Loading...
HomeMy WebLinkAbout042-93 Cliff Borden - Back Creek - BackfileRECEIPT Nn 023910 AMOUNT DUE AMOUNT PAID 1072 L__-v BALANCE DUE s - t� - PAID BY CASH X_CHECI{�'+ 1 /�--'7 ❑ OTHER FREDERIC , 1.:_ :..:,'r' C_.h PANNING AND DEVELOPMENT P.O. BOX b0i. i.l:. (.ii iJ .T. WINCHESTER, VIV.,­ i,i RECEIVED FROM ADORES THE SUM OR FOR f oc DATE ✓ f `// �� C�/7��,(/f / / DAYTIMERSRE-ORDER No. 3221 - Printed in USA It 1 ! UK - 1 o/26/g3 pK - 8I13I93 * STAFF SITE PLAN CHECKLIST * This application is not complete if the following are not included: One set of comment sheets from the following agencies along with any marked copies of the plan; '--'VDOT ✓ Sanitation Authority OK - 9 /13 Inspections Dept. 014 - 9 1 19 3 f Fire Marshal OK- I � County Engineer Airport Authority 2. One copy of the Site Plan application. ✓ 3. Five copies of the Site Plan. 4. One reproducible copy of the Site Plan (if required). 5. One 35mm. slide of the Site Plan (if required). TRACKING City of Winchester Town of Stephens City Town of Middletown Health Dept. Parks & Recreation Soil & Water Conservation Dist. Date Application received. All necessary agency comments received. Fee Paid (amount $ b' 9 Site Plan to Planning Commission via bi-monthly. /' )V4- Site Plan heard by Planning Commission (if required). 0#14y. Revisions received (if required). Date of approval. Info added to . i COUNTY of FREDERICK I Department of Planning and Development 703 / 665-5651 Fax 703 / 678-0682 September 22, 1994 Cliff Borden Truck Parts Unlimited, Inc. P.O. Box 598 Stephens City, Virginia 22655 RE: Cliff Borden Truck Parts Unlimited Inc Revised Site Plan Approval Dear Mr. Borden: Mr. Keith Burr of Greenway Inc., provided our department with revised site plans for your retail and warehouse facility located in the Battlefield Partnership subdivision. This site plan was revised to remove the eleven parking spaces and maneuvering area that were located on the northern potion of this site. The revisions to this plan were approved by the County Engineer, the Fire Marshal, and our department. I have provided you with two copies of the revised final site plan. This will enable you to provide the contractor with a copy and keep a copy for your records. All required improvements specified in my original letter, dated January 31, 1994, still apply to this project. Please contact this office to schedule a final inspection of this site once all improvements are complete. Please contact me if I may answer any questions regarding this letter. Sincerely, Evan A. Wyatt Planner II EAW enclosure cc: Keith Burr, Greenway, Inc. 9 North Loudoun Street P.O. Box 601 Winchester, VA 22601 Winchester, VA 22604 COUNTY of FREDERICK Department of Planning and Development 703 / 665-5651 Fax 703 / 678-0682 April 28, 1994 Cliff Borden Truck Parts Unlimited, Inc. P.O. Box 598 Stephens City, Virginia 22655 RE: Cliff Borden Truck Parts Unlimited, Inc. Revised Site Plan Approval Dear Mr. Borden: Mr. H. Bruce Edens, L.S. of Greenway Inc., provided our department with revised site plans for your retail and warehouse facility located in the Battlefield Partnership subdivision. This site plan was revised to reduce the total floor area from 9,000 square feet to 6,000 square feet, lower the finished floor area, and alter the overall site grading plan. The revisions to this plan were approved by the County Engineer, as well as our department. I have provided you with two copies of the revised final site plan. This will enable you to provide the contractor with a copy and keep a copy for your records. All required improvements specified in my original letter, dated January 31, 1994, still apply to this project. Please contact this office to schedule a final inspection of this site once all improvements are complete. Please contact me if I may answer any questions regarding this letter. Sincerely, &� �. 4�-- Evan A. Wyatt Planner II EAW enclosure cc: T. Roy Jennings, Director of Real Estate H. Bruce Edens, L.S., Greenway, Inc. 9 North LOUdMin Strcct P.O. Box 601 Winchester, VA 22601 Winchester, VA 22604 0 • i COUNTY of FREDERICK Department or Planning and Development 703 / 665-5651 Fax 703 / 678-0682 January 31, 1994 Cliff Borden Truck Parts Unlimited, Inc. P.O. Box 598 Stephens City, Virginia 22655 RE: Cliff Borden Truck Parts Unlimited, Inc. Site Plan Approval Dear Mr. Borden: The Frederick County Planning Department administratively approved Site Plan #042-93 of Cliff Borden Truck Parts Unlimited, Inc. on January 26, 1994. The approved site plan calls for the construction of a retail and warehouse facility that will be 9,000 square feet, the creation of a paved parking lot that contains a commercial entrance that is 50 feet in width, 41 regular parking spaces, 2 disabled parking spaces with a disabled ramp and appropriate signage, CG-6 curb and gutter and perimeter and interior landscaping, a concrete sidewalk that is 4 feet in width, a business sign that is 16 square feet in area and 20 feet in height and all appropriate erosion and sedimentation control measures. I have provided you with two copies of the final site plan. This will enable you to provide the contractor with a copy and keep a copy for your records. Please contact this office to schedule a final inspection of this site once all improvements are complete. Please contact me if I may answer any questions regarding this letter. Sincerely, &M� a— . jW-- Evan A. Wyatt Planner II EAW enclosure cc: James L. Longerbeam, Back Creek District Supervisor T. Roy Jennings, Director of Real Estate Keith Burr, Greenway, Inc. 9 North LOUdoun Strect P.O. Box 601 Winchester, VA 22601 Winchester, VA 22604 COUNTY OF FREDERICK, 4GINIA i DEPARTMENT OF INSPECTIONS Caller wE=C= �'i oTime Called —,) Date Called 51zz 19 1 Phone No. �o(o�J - �D� Time Requested A S" Date Requested A5A P Received By A V\Apm- Date of Inspection s 17- 9 L2 PERMIT HOLDER NAME 1 ti L - Rv kL_o _ RT. NO. Lot No. SEC. No. SUBDIVISION D�►tt�F+� L-� A rr"E72--1A P STREET NAME V_ AU-Q!f P1 KC - DIRECTIONS 71URr_J BUILDING NO. M WKPe 111-00 DZI VC ' 5 +1\ PLUMBING NO. U fJ Co+2r•l�1G. h.3 l�K ) ELECTRICAL NO. PERMIT FOR: N.�PA T2-,C.K, PPr2'l� Type of Inspection Residential Footers Setbacks: FR Slab Draintile Water Service Sewer Rough Electric Rough Plumbing Rough Mechanical Groundworks Gas Piping/Test Other: MECHANICAL NO. SIGN NO. DISTRICT -sAC < c gmz Commercial f BK Gas Fire -up Framing Final Final Building L R_ Final Electrical Final Mechanical Site Plan Fire Marshall Final Plumbing Special/Complaint — Time In: 14 pm Temperature 8S 0r Cut in No Time Out: ��.' �� fM Weather SUrJ�l�/ Results: Approved V 1 /� Rejected - Comments: At l._ CJ I-TC it K l M Pug-'1'E _ Signature �L Date ThG- COUNTY OF FREDERICK, VIAIA DEPARTMENT OF INSPECTIONS Caller L . N.. Li QSc° 'N Time Called 12. 1 d 5 vM Date Called 2 /ZZ bs Phone No. G (e2 — Sb30 Time Requested hSAP Date Requested Received By ��^} A - ti'V Yfy'►i'— Date of Inspection Z I23 I95- PERMIT HOLDER NAME I- • �- L • Bu 1u-ntVZ� RT. NO. I 1 :5 Lot No. SEC. No. SUBDIVISION A P STREET NAME 16929!j PIKE DIRECTIONS fI S Tu RrJ (L) G1J : ;, BUILDING NO. HA-RA•'Ti+n0 Dk+N C 50Tr- PLUMBING NO. n ►J C_AR_► CZ n" Q ! ELECTRICAL NO. MECHANICAL NO. PERMIT FOR: C`1 F i= _%Qpez Tizo<.< Tvoe of Inspection Residential Footers Slab Water Sewer Rough Plumbing Groundworks Other: Setbacks: FR _ Draintile Service Rough Electric Rough Mechanical Gas Piping/Test SIGN NO. DISTRICT 13ACK CIZr�. f Commercial v` BK L R Gas Fire -up Final Electrical Framing Final Mechanical Final Site Plan Final Building Fire Marshall Final Plumbing Special/Complaint Time In: 9 . V in, Temperature k- 4 4 F Cut in No. Time Out: 10 - 1_3,Awl Weather AV9QEA^_:—r _ Results: Approved Fn , 911 I? • 0- Rejected 1 Comments: PR Gy i or_ ALL RC Q w C Cb L_A•aJhSC PrP, 0(r . 7 C9 f A'ZC A4J L STRQ! La ZC` ut) EA H-£01S Rc7rt pvE qt1 _ C dJ S cn o,� DEIt3fZ 1 5 P�'Ov 1 (J� (� 1 P - R Ptt'' I rJ Signature UJCt.i�� Date — P 0 SITE PLAN APPLICATION Complete the following ag-olicat:Lon: DATE 12-1 -93 APPLICATION 9,3 1. Development 0.l.i F 1= GoebF-M S 11-C P°LA M 2. Location of Property: COMMOM OP dt, VMl1TE 11 Ngatam PULE (by street name) _AMD MAaAT"M bfL,t UE 19 BRTtLeP1CIZ PArzraEdi.S1+1P pEvewPMEmr 3. Property Owner: C L.% PF 609-bam Address: `t"{Z.IICV- PACM OKWMITEb. IIllC,. - P.o. C30k 598 Telephone: 4. Applicant/Agent: 12.EaM,44pU 1AlC, Address: 7fl Q p1E�G2 (P(�111f ul� mr-4 a4ree- � 4. 2260a, Telephone: (o&2 - 41 lb ro 5. Designer: S&Mg AS A and r Address: Telephone: Contact: K, a 1 TM 6. Is this an original or revised Sit Plan? Original Revised -5- 7. Total area of parcel to be developed: 32,401 Ga, FT, 8. Property Information: a) Property ID # : b) Current Zoning: B-Z c) Present Use: VAQ Ant'r d) Proposed Use: 2FTAIL /WAeSftda& e) Adjoining Property Zoning: 5.E.: 8-Z M. P�-1 f) Adjoining Property Use: ft~FiP.c t 4L g) Magisterial District: '1 ACK- Lr—F-C-K I have read the material included in this package and understand what is required by the Frederick County Planning Department. I also understand that all required material will be complete prior to the submission of my site plan. Signature: \� Date: f GREENWAY, INC. 970 BAKER LANE WINCHESTER, VIRGINIA 22603 703 662 -4196 H. BRUCE EDENS. L.S. rRESIDENT LETTES OF THANS I'll TTAl Pkeb . & . PLAm i tab flp—m. G 6-10rl EMCA1 I'YC A eC SCIV,01l/6 YOU Tf/E ATTACHED CO //CS PA T C A/O. DES C Z /PT/O.tJ 5 ( ER. 146ENC �!l SE — AP?tt TtbI.I TNES�E/ Aye E TA°.4�cISM/TTEo �o.s GNEcA: EO a E� OrY bd FOB' AP/,CO�'.9L ❑ ,CESU6M/T7E0 COP/ES ,rae o^o,,zoA,44 ❑ FO,e 1�'O!/,e USE ❑ sUBM/TTEU COf /ES I -a e oI57, lBUTlaAl ❑ AS eEQUESTED ❑ f 0x envI & I` COMMENT ,eEMA,e.e.S o eC7'U,eNED ca e e cC7"ED Pe/NT..S n GREENWAY, INC. 970 BAKER LANE WINCHESTER, VIRGINIA 22603 703 662 -Albs M. BRUCE EDENS, L.S. PRESIDENT 4�e�, IL=6TIc[m' Q)F UTMQ -sA0=Q&. JA N 1994 r RECEIVED W y{. DEPT. OF PLANNING v t,. AND DFvri'f'— �s G 6-Affe EME.t/ /VE A,eE SEti/O/�c/G YOU T//E ATTACHED Pie/.VTS Co /ieS .A -rc A/O. oe_f C.0 /PT/O.v CO SITS PLAM - CLIFP 15,09tceNI Tf,/ESE A,eC T,e.4AIJA4'/TTEO 4J CNEOeED BC'.0. V d-OZ .4 P/ 0,64Z .CESU6M/TTEO lap/ES fO,e A,,opP,C4a"z ❑ Frox l'OU,e 4IJd- ❑ SUBM/TTEU COP/ES I -a e ❑ AS ,ee0&/C-f7EO ❑ .ecr4le 16-42 CO.C,eEC/EO Re%1/T.S ❑ FOe xexle 9' 4 comlwE.t/T ❑ �L J s/c A/EO : r CLIFF 2102 oe-►J S P, / -2 f 94 APPLICANT'S CIC:{LL� Your site plan s:_cu? d include the followinc; Admi ni strat4ya Y N 1. Na-e of proposed development 2 . Na_;,e and adL-ess of ow-n- ,- 3. Nane and address of develocer 4. Name, address, and phone number of designer 5 ca icate of surveyor, engineer, or architect 6 • Date plan prepared and date of revisions PZA 7 • A 1 is-ing of all conditions placed on the sits as a result of a conditional use pe_r-ait or conditional. — zcr._:.g approval 8 • A space labeled "approved by the Zoning Administrator" for the approval approval signat sre and date cf General Site Tn-,,,-,at cn Y N v _ 9. Location map (scale 1: 2000 ) _ 10. Magis-anal District of site 11. Scale of site plan (not to exceed 1:50 ) 12. Ncr-�h Arrow _ • Zoning of site 14 Use and zoning of adjoining properties Lots/Uses/Bui?dT^cs & Structures Y N ✓ ' _ 15. Su_-veved boundaries for all lets and parcels _ 16. Acreace of all lots included in the plan 17. The location and dimensions of all required setbacks and yard areas 18. Location of all buildings, structures, and uses = 19. The proposed use of each building, structure, and _4�� A 20. area The location and type of all dwelling units 21. Ground floor area and total floor area of all - buildings Stith FAR calculations for commercial and industrial _ zoning districts -The height of all buildings and structures 3 •) The location and dimension of all signs 7 Lets/Uses/Build_ncs & Structures (con' - Y N : 25. Lccation of cutdccr lichting fixtires — 26. Lccation Lccation and nal:'a e of cutdccr storage areas _ 27. Lccation and and area of ccmmcn open space- description 28. Lccation of of a__ recreation facilities sidewalks qZ� Lccation of a -rid pedestrian wav_ s outdoor trash receptacles Y N 30. Name and number of existing and planned streets or, / — a-rd adjoining the site 1. 1/ 3Lccation of existing and planned streets on and — adjoining the site 32. Dimensions, boundaries, width, pavement, and c:.nst_--ucticn of planned roads \ _ 33. Lccation and dimensions of all proposed e^ rarces from public right-al..-ways Utilities Y N ��� ,,. L�l. ram, GCS �4 _ 34. Location of all utilities, including sewer lines with the and water size Lccation and width of lines, mains, and of all laterals 36. access, utility and Lccation easements, drainage easements including _ and nature of fire lanes, fire hydrants, and all other facilities necessary to meet the Fire Ccde rec_uirements a rt. c ; n '� /4pp•w� 13 Mu Y . N. _ 37. Calculations describing the .required number of — parking and loading spaces 38. Location and dimensions of all parking and loading spaces, driveways, parking aisles, curbing, and other features to be used 39. Location and dimension of all handicapped spaces Natural Features Y N / ✓ 40. Existing and finished contour Lines 41. Lccation of steep s? cpes, woodlands, flood=lai_*:s, wetlands, sinkholes, and other environmental f ea ','--sres _ LA 42. Lccatien of streams and drainage ways T andsca _''C V N 43. La.Tdscaping plan describing location and tees o plants to be used 44. Lccation of required buf=ers and screening with cross sections or profiles Zres i cn and Se.= - - en t C^ntrn, Y N _ 45. A stormwater Management p l an wit_ ran of= c ._--lations and cn and description cf i facilities to be used _ 46. Soil erosion and sedimentation control plan wita Lccation, types, and examples of provisions to be used COMMONWEALTH of VIRCjINIA RAY D. PETHTEL COMMISSIONER Mr. Austin Spitler C/O Greenway, Inc. 970 Baker Lane Winchester, VA 22603 Dear Austin: DEPARTMENT OF TRANSPORTATION P. O. BOX 278 EDINBURG. 22824 September 27, 1993 jKs^ WILLIAM H. BUSHMAN RESIDENT ENGINEER TELE (703) 984-4133 FAX (703) 984-9761 Ref: Cliff Borden Property Battlefield Partnership Development Routes 11 & 1091 Frederick County As requested we have reviewed the above referenced site plan dated July 21, 1993. Our recommendations may be found on the enclosed plans marked in red and as follows: 1. The typical section of the improvements along Route 1091 will need to be revised as noted. 2. A standard CG-12 handicap ramp will need to be provided at the intersection with Route 11 and Route 1091. 3. Additional drainage information will need to be added to the plan where the proposed curb and gutter along Route 11 ties in with the existing curb at the south end of the property. 4. Site distance, speed limit and reference information will need to be added for Route 1091. Please revise and resubmit six (6) copies for final approval. Should any changes be deemed necessary, please design them to meet or exceed the above recommendations. Should you have any questions, please let me know. Sincerely, William H. Bushman Trans. Resident Engineer I By: Robert B. Childress Hwy. Permits & Subd. Spec. Senior RBC/rf Enclosure xc: Mr. J. B. Diamond, Mr. S. A. Melnikoff, Mr. R. W. Watkins TRANSPORTATION FOR THE 21 ST CENTURY i Virginia Department of Transportation Attn: Resident Engineer -P.O. Box 278 Edinburg, Virginia 22824-0278 (703) 984-4133 The local office of the Transportation Department is located at 1550 Commerce St. in Winchester if you prefer to hand deliver this form. Applicant's name, address and phone number: dE`>12EexLvQ�4u . Jae. 662-41 bra Name of development and/or description of the request: - 0 L Location: Va. Dept. of Transportation Comments: See attached letter from W. H. Bushman to Greenway, Inc. dated 10/28/93. VDOT Signature and Date: ZJ /V . �K�- ++'Z�-<-� •. /0 (NOTICE TO RESIDENT ENGINEER* PLEASE RETURN THIS FORM TO J&Pi;1V4jM. NOTICE TO APPLICANT it is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Also, please attach threQ copies of your plans and/or application form. -10- 4 -% at 1 RAY D. PETHTEL COMMISSIONER COMMONWEALTH of VIRGINIA Mr. Keith H. Burr C/O Greenway, Inc. 970 Baker Lane Winchester, VA 22603 Dear Keith: DEPARTMENT OF TRANSPORTATION P. O. BOX 278 EDINBURG,22824 October 28, 1993 WILLIAM H. BUSHMAN RESIDENT ENGINEER TELE (703) 984-4133 FAX (703)984-9761 Ref: Cliff Borden Property Routes 11 & 1091 Frederick County We are in receipt of the above referenced project's revised site plans dated October 21, 1993. It appears all of our earlier recommendations have been satisfactorily addressed. Please advise the owner.of our approval .and that the appropriate land use permits will need to be applied for and issued prior to initiation of work. Said permits will require a minimal processing fee and surety bond coverage. If you have any questions, please let. me know. RBC/rf Enclosure xc: Mr. S. A. Melnikoff Mr. R. W. Watkins Sincerely, William H. Bushman Trans. Resident Engineer By: Robert B. Childress Hwy. Permits & Subd. Spec. Senior TRANSPORTATION FOR THE 21 ST CENTURY FCSA 171 REQUEST FOR SITE PLAN COMMENTS Frederick County Sanitation Authority �� Attn:' Engineer Director LL 199 Front Royal Pike u J P.O. Box 618 Winchester, Virginia 22604 (703) 665-5690 The Frederick County Sanitation Authority is located on U.S. 522 South, one tenth of a mile from the U.S. 50 North intersection, if you urefer to hand deliver this review. Applicant's name, address and phone number: w�wcif�STE� � v��. ZZ6 0 3 G�?-4iBS Name of development and/or description of the request: Location: /FT 3 7 ( SGUr1-/ Sanitation Authority Comments: 0V4rw •dS OVD T,Fd 44,411E C'bt A&J " 'r SAAW oMF / *9,WM L I E 46. L P tAkfr/e torI%1 - I )0 4 Ar 101 !.) Sanitation Authority Signature & Date (NOTICE TO SANITATION AUTHORITY +� THZS FgRM�P��1►NT • I NOTICE TO APPLICANT It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Also, please attach a copy of your application form, location map, and all other pertinent information. L.V E L 0 I"A I i Control No. OM3927% LaLw Neceiveo 081292 Roolu"Un ...... . . ..... ...... I ......... Applicant Name jreeway inc. ... . ........ . ....... . Addres-Ei 9% Baker Lan,.:� . ...... .. . . . . ....... . .. ... . . ... ... . ... . ........ ...... . ... . . .......... Winchester, VA 2260i ... . ................. . ..... . .......... . ....... .... . ..... Project Name MUT U; Ja;-I --.- ---- .. ..... ... . .. ........ . .. . ...... .. ... ... .. ....... . Phone No. 701-66d-4102 Type of Applination w-I ist Due Fire Cc. 11 is! bic Rasoua LO, II Election Di_ w.ct SaLk CCwU!:: ......... ... ..... RECOMMENDAUON'.' Automatic Sprinkler SyLtum x Residential Uu inkier IyLtwifi Automatic Fire Alarm Systum x Other .... . . ...... Emergency Vehicle Access; Hydrant Locarions5 Adequate x ... . ........ . ...... . Siamese Conneation Lozjtown, Approved ................. . N-L Approvud Nou Additionai Commonts! 1. tomparacy :�jc,. o njArn"" construction ... . ... Legion. . ......... .. .... . ....... . ...... . ......... qo""/ ..... . ....... . ... ...... V,Qlcjw� at all tiill ea ..... ........ Wring CunabrULCIOn. 3. O'n ntnj of con,WMLio" "ObrIn 1',4 . . . . . ... . .............................. not permitta, . .......... .. . .. . . ... . . ........ ... ........... cn wita. A. "no of tamp 0 1 i no, t "I J-, On , f "W t 1 U ..— . . . . . .. . .......... . .............. must comply . ..... -.1 1 ........ ....... witm State ...... . ..... .. ....... ...... . . .. . ............ . .... . ....... . . . ........... .. . . ......... ........ .. ... . . ................ . .... . . ......... . . - ------------------- ... . ..... ... - 11 ... ........... ... . ....... . ..... I Kro Wravontion Coin. . . .... ....... .. .... ... . ..... . ..... ... .. ...... ........... ....... ...... ......... . .. . . .. . -.. . ...... ---- ... ....... . ..... . ......... .. ..... ... .......... .. .... ..... .. . . . .... ... ....... . .. .... ..... . . . ......... . ....... .... .... ...... ... . ... ... ... .. ............ . ...... .. .. ..... . ... . ... ....... . . . .... ..... . . .......... . ........ . ......... I .. ........ . . ... ... ....... ........... . .. ..... ...... . . ........ .. ... ... . . —.- ......... . . .. - . .... . . ..... .... ... ...... .... .... ...... .... .. ...... . .... ... ... ... ... .. ... ....... . .......... .. .... .... . .... . . . ... .... --------- . ......... ..... ... ........... . .... .. .. ....... . . . . .... .. . ........ . . ..... . . . ...... ..... . . ..... .... . . . ................ . . ... ..... . ... ........ . .......... .. ...... ..... ............ ...... ..... .... ....... .. .. .... . . ....... .... Review Time Tb Mr. . .. . ....... I ............... Douglas A. KiraC.iW-� Fire Marshai REQUEST FOR SITE PLAN COMMENTS Frederick County Inspections Department At tn: JQhn S. Trenary, Building Official P.O. boX 601 Winchester, Virginia 22601 (703) 665— 5656 The Frederick County Inspections Department is located at 9 North Loudoun St., 2nd Floor of the Hammon Building in Winchester, if you prefer to hand deliver this review. Applicant's name, address and phone number: 62- -,,t/8S Name of development and/or description of the request: /30,oeOZ�7ti 5/7-Z- PL.f.0 Location: ,e i � // ZSojrf/> e 1,� - 3 7 Inspection Comments: Building shall comply with the Virginia Uniform Statewide Building Code and Section 308, Use Group M (Mercantile) of the BOCA National Building Code/1990. Other codes that apply are title 28 Code of Federal Regulation, Part 36 Nondiscrimination on the Basis of Disability by Public Accommodations and in Commercial Facilities. (Reference Section 1002.10 of the 1990 BOCA Windowless Story in regards to sprinkling basement) Handicap parking space area shall not slope anv greater than 2%. Engineers Signature & Date: C .(NOTICE TO DEP P EASE RE RN THIS RM TO APPLICANT.) NOTICE TO APPLICANT It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Also, please attach two copies of your plans and/or application form. -13- COUNTY of FREDERICK Harvey E. Strawsnyder, Jr., P.E. Director of Public Works 9 North Loudoun St., 2nd Floor 703/665-5643 September 17, 1993 Mr. Bruce Edens, C.L.S. .`�� Greenway, Inc. mac` I;�� 1994 i-F 970 Baker Lane Winchester, Virginia 22603 :IVEQ � ^ DEPT.:+ PLANNING RE: Cliff Borden Site Plan AND D1-41OPMENT Battlefield Partnership Industrial Park Frederick County, Virginia 9S,� G ��► Dear Bruce: The recent completion of the stormwater detention facility at the Battlefield Partnership Development resolved our final review comment for the Cliff Borden site plan. Consequently, we recommend approval of the subject site plan with a revision date of November 16, 1993. Based on the proposed grades, we anticipate that the basement storage area will be located entirely below the exterior finished grade, thus a foundation drainage system will be required. As a result of our previous review comments, a foundation drainage discharge location was shown on the site plan. The actual foundation drainage design should be coordinated with the site plan to insure proper conveyance of the discharge to a designed drainage channel. Please convey the above design requirements to your client so that they can be incorporated into the building design. The foundation design shall be included with the building design submittal. Please contact me directly if you or your client has any questions regarding our requirements related to foundation drainage and water proofing. Sincerely, Harvey y E. Strawsnyder, Jr., P.E. Director of Public Works HES:rls cc: Evan Wyatt, Planning and Zoning ✓ John S. Trenary, Inspections Department file Fax: 703/678-0682 - P.O. Box 601 - Winchester, Virginia - 22604 • 0 COUNTY of FREDERICK Harvey E. Strawsnyder, Jr., P.E. Director of Public Works 9 North Loudoun St., 2nd Floor 703/665-5643 September 17, 1993 Mr. John Gast Greenway, Inc. 970 Baker Lane Winchester, Virginia 22603 RE: Cliff Borden Site Plan Battlefield Partnership Industrial Park Frederick County, Virginia Dear John: We have completed our review of the site plan proposed for the Borden property and offer the following comments: 1) The development of the Borden property assumes that all stormwater will be diverted to a regional detention pond located on property owned by the Battlefield Partnership. This facility was designed by Greenway, Inc. in August 1991 and approved by Frederick County for construction as part of the master development plan. However, to date, the detention facility has not been constructed. Consequently, we must deny approval of this site plan until such time that the detention facility has been constructed or has been bonded for construction. This office had previously contacted Mr. Richard Hardison of the Battlefield Partnership and informed him of this requirement. He had indicated that he would initiate construction in accordance with the plans prepared by Greenway, Inc. We suggest that a meeting be scheduled with all interested parties to discuss the construction of this facility. 2) The design of the regional stormwater management facility was based on a post -development "C" value of 0.76. The proposed development of the Borden lot which includes approximately 81 percent pavement or building yields a weighted "C" value of 0.80. Slightly increasing the landscaped area will reduce the weighted "C" value. 3) Indicate spot elevations on the sidewalk along the west side of the proposed building. Fax: 703/678-0682 7 P.O. Box 601 - Winchester, Virginia - 22604 0 0 Mr. John Gast Page Two September 20, 1993 4) Indicate spot elevations at the west entrance of the proposed building. 5) The proposed building elevations indicate a basement level at elevation 727.00. Based on the proposed finished grades, a foundation drainage system consisting of a sump and pump will be required. The pump shall be designed to discharge to a designated drainage easement rather than the sanitary sewer. Indicate this discharge point on the site plan. 6) Provide a typical ditch cross section as indicated in the design calculations. Please contact me if there are any questions regarding the above comments. Also, I am available to discuss the issue related to the stormwater detention facility. Sincerely, Harvey E. Strawsnyder, Jr., P.E. Director of Public Works HES:rls cc: Evan Wyatt, Planning and Zoning( file